Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG19-0160 - WESTFIELD SOUTHCENTER MALL - REMODEL RESTROOMS, FIXTURES AND WATER HEATERS
SOUTHCENTER MALL RESTROOMS 2800 SOUTHCENTER MALL PCI 9-0160 Parcel No: Address: ~^ xx °~ Tukwila "_ ^ uxn v K x na Department ofCommunity Development G3UUSouthcenterBoulevard, Suite #1OU Tukwila, Washington 98188 Phnne;206-431-3670 Inspection Request Line: 206-438'9350 web site: http://www.Tuk%AjilaWA.gov PUQMB|yU PIPING PERMIT 35970001SO Permit Number: PG19-0160 Project Name: 3OUTHCENTEKMALL RESTROOMS Issue Date: 12/30/2819 Permit Expires On: 6/27/202G Address: Contact Person: Name: Address: Contractor: Name/ Address License No: Lender: Name; ,,WA, STONE FAISON P4R|SPLUMBING & HEATING INC 11535l5AVNE, SEATTLE VVA,98l25 PAR|SPH10SK4 ''' Phone: (206)342-0I21 Expiration Date: 12/21/2021 DESCRIPTION OF WORK: REMODEL PUBLIC RESTROOMS, FIXTURES AND WATER HEATERS. Valuation of Work: $54,000.00 Water District: Sewer District: Fees Collected: $396.79 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: National Electrical Code: VVACities Electrical Code: VVACZ96'46B: y Code: Permit Center Authorized Signature,: Date: t-9 |hearbycertify that | have read and examined this permit and know the same Uzhetrue and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permlit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction orthe performance ofwork. (amauthorized tosign and obtain this deve|opmentpermit and agree tothe conditions attached tothis permit. _ Print Name: CX`' f_�> Date: /W-_307c? This permit shall become null and void if the work is not commenced within 180 days for the date of issuance,or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: I: ***PLUM8|NG/GASPIPING PERMIT [ONDOlONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall bemaintained at the job and available 1othe plumbing inspector. 4: All plumbing gas piping systems shall be installed incompliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: Noportion ofany plumbing system orgas piping shall heconcealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall beconducted inthe presence ofthe Plumbing Inspector. |\ shall bethe duty nf the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work isready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall beinsulated Uzminimum R'l 8: Plastic and copper piping running through framing members towithin one (l)inch ofthe exposed framing shall beprotected bysteel nail plates not less than 18gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing p\pingsbaU be directly embedded in concrete or masonry. lO: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall beprotected inaccordance with the requirements ofthe building code. 11: Piping |nthe ground shall belaid onafirm bed for its entire length, Trenches shall bebackfiUed\nthin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, dnderOU'frozen earth, orconstruction debris. lZ: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance ofthejudsdicdon. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 40ZcfWashington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)438-935D 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWIC: Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. TG Project No, Date Application Accepted: Date Application Expires: 59-0 0 (For office use only) e_7215,_ PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 920247-0010 King Co Assessor's Tax No.: Site Address: 2800 Southcenter Mall, Seattle, WA 98188 Suite Number: Floor: 1 Tenant Name: Unibail-Rodamco-Westfield PROPERTY OWNER Name: Unibail-Rodamco-Westfield Address:2800 Southcenter Mall City: Seattle State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Stone Faison Address: 1326 Fifth Ave, Suite 400 City: Seattle State: WA Zip: 98101 Phone: 206.342.0121 Fax: Email: StoneF@BurgessPNW.com New Tenant: Yes 2..No PLUMBING CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 511 00 0 Scope of Work (please provide detailed information): This project requires demolition of existing plumbing fixtures and (2)Two Hot Water Heaters. New plumbing fixtures and (1)One Hot Water Heater to replace existing and be connected to existing plumbing drains. Building Use (per Intl Building Code): M - Mercantile Occupancy (per Int'l Building Code): Retail Utility Purveyor: Water: City of Tukwila / King County Sewer: City of Tukwila / King County 11:1ApplicationsTorms-Applications On Line \ 201 I Applications‘Plumbing Permit Application Revised 8-9-11.docx Revise& August 2011 Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity elow: ow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks 4 Rain water system — per draM (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 2 Lavatory 5 Urinal 2 Water heater and/or vent I Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Stone Faison Mailing Address: 1326 Fifth Ave, Suite 400 Date: 10.18.19 Day Telephone: 206.342.0121 Seattle WA 98101 City State Zip HAApplicationsTorms-Applications On Line \ 2011 Applications \Plumbing Permit Application Revised 8-9-1 I .docx Revised: August 2011 Page 2 of 2 Receipt Number DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $322.29 PG19-0160 Address: 2800 SOUTHCENTER MALL Apn: 3597000150 $322.29 Credit Card Fee $9.39 Credit Card Fee R000.369.908.00.00 0.00 $9.39 PLUMBING $298.00 PERMIT FEE R000.322,100.00.00 0.00 $263.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 TECHNOLOGY FEE $14.90 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R19190 R000.322.900.04.00 0.00 $14.90 $322.29 Date Paid: Tuesday, December 03, 2019 Paid By: RYAN ADKINS Pay Method: CREDIT CARD 06652G Printed: Tuesday. December 03. 2019 9:52 AM 1 of 1 0 CO TUKWIL4 ETRAKIT 6300 SnVTHCENTER gLVD TUKWILA^ NA 98188 206'433-1870 CITY OF TUKWIL4 0017340000802374464500 Date: 12/03/2019 89:52:21 AM CREDIT CARD SALE VISA CARD NUMBER: **********9969 K TRAN AMOUNT: $322.29 APPROVAL CV: 86652G RECORD #: 000 cLsno ID: frankie X z AGREE TO p«v THE xaOvc TOTAL AMOUNT 4{[UnDzwG TO THE [AKo ISSUER AGREEMENT (MERCHANT AGnesnsmT IF CREDIT VOUCHER) Thank you! Merchant Copy Cash Register Receipt City of Tukwila Receipt Number R18863 PermitTRAK DESCRIPTIONS ACCOUNT '' • • ••..:,•••,„••,••••••••••.,.-,•• • D19-0334 Address: 2800 SOUTHCENTER M DEVELOPMENT QUANTITY •••'.••140' PAID ,190.007: $3,115.50 $3,115.50 PLAN CHECK FEE R000.345.830.00.00 0.00 $3,115.50 PG19-0160 dresS::2800SOUTHCENTERIMALL-qo A ri ti 3597000150 74.50A-; PLUMBING $74.50 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R18863 ' R000.322.103.00.00 0.00 $74.50 $3,190.00 Date Paid: Friday, October 18, 2019 Paid By: BURGESS DESIGN Pay Method: CHECK 016835 Printed: Friday, October 18, 2019 3:52 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 csiejo Project: /'�� ,J�� '1 ,5'Type of Inspection: Address: Ce) Sdv eir•OZA - Date Called: Special Instructions: �r. . Date V1far ted: p-m- Requester: 14. hone Nei EjApproved per applicable codes. orrections required prior to approval. COMMENTS: ns Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectian. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Type of Inspection: Address: Date Called: Special Instructions: /77 of 7;l ,Date ' Wanted: a,m. p.m. Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COIIr+IMENTS: nspec l Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431 670 'Project: Type of nsp on: ITZ Address: Date Called: Special ns uc n : -01.45a)(0) i&bg R Date anted: a.m. p.m. Requester: Phone No: 7/ tfria 3 Approved per applicable codes. orrections required prior to approval. COMMENTS: nspec jDate: //2 /? REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. (11ERMIT COORD COPY o PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0160 DATE: 10/18/19 PROJECT NAME: SOUTHCENTER MALL - RESTROOMS SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division ffit16 11\16\ Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable (no approval/review required) Planning Division Permit Coordinator 11 DATE: 10/22/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/19/19 Approved Approved with Conditions r Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections; Bldg 0 Fire 0 Ping 0 PW fl Staff Initials: 12/18/2013 0 Some online services are currently unavailable. See a list of service outages. (httos: In". a,goviagency/system-statusl labor & Industries (https://lni.wa,gov) Contractors EARIS PLUMBING & HEATING INC Owner or tradesperson Principals PARIS, JAMES EDWARD, PRESIDENT PARIS, MARCIA ANN, SECRETARY Doing business as PARIS PLUMBING & HEATING INC WA UBI No 601 185 959 11535 15TH AVE NE SEATTLE, WA 98125 206-362-8950 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. PARISRI-1105K4 Effective — expiration 05/24/1990— 12/21/2021 PP114 FEDERATED MUTUAL INS CO $12,000 00 Bond account no. 9415323 Received by L&I Effective date 12/05/2002 11/22/2002 Expiration date Until Canceled Insurance Federated Mutual Ins Co $1,000,000.00 Policy no. 9849262 Re,ceived by L&I Effective date 10/17/2019 11/27/2019 Expiration date 11/27/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&l Tax debts No LW tax debts are recorded for this contractor license during the previous 6 year period, but some debts maybe recorded by other agencies. License Violations Infraction no Satisfied GENERAL SYMBOLS DUCTWORK (CONTINUED) ABBREVIATIONS 12%- LIGHT LINE INDICATES BACKGROUND LIGHT LINE INDICATES EXISTING WORK HEAVY LINE INDICATES NEW WORK MATCHLINE OR PROPERTY LINE EXISTING WORK TO BE REMOVED POINT OF CONNECTION SHEET NOTE REFERENCE CALLOUTS DETAIL IDENTIFICATION LETTER INDICATED SECTION SHEET NUMBER WHERE SECTION IS DRAWN DRAWING REVISION DESIGNATOR REVISION NO. PLAN AND DETAIL TITLE CALLOUT (DRAWING/PLAN TITLE) SCALE: (DRAWING/PLAN SCALE) (DETAIL TITLE) SCALE: (DETAIL SCALE) (REFERENCE DRAWING #) 0 DIFFUSER AND GRILLE CALLOUTS CEILING DIFFUSER CALLOUTS TYPE: CD = SQUARE FACED CEILING DIFFUSER (SIZE AS INDICATED), SEE DETAIL CD10-250 - DESIGN CFM DIFFUSER NECK SIZE, INDICATES ROUND (10"0) GRILLE CALLOUTS TYPE: EG = EXHAUST GRILLE / RG = RETURN GRILLE (CFM NOT INDICATED) ®© INDICATES SIZE, ONE NUMBER INDICATES SQUARE (10"X10") WHEN NOT INDICATED, REFER TO SCHEDULE FOR NECK SIZE EGA10-250 —\— DESIGN CFM, WHEN INDICATED, NO BALANCING REQUIRED - TYPE (A, B, ETC.) ONLY WHEN MORE THAN ONE TYPE IS REQUIRED EQUIPMENT CALLOUTS UNIT CALLOUTS TYPE: RTU = ROOFTOP UNIT CDF = CEILING DIFFUSER FAN WH = WATER HEATER UNIT NUMBER DUCTWORK DUCT (1ST FIGURE = SIDE SHOWN, 2ND FIGURE = SIDE NOT SHOWN, NOTE: INSIDE FREE AREA DIMENSION) DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED SUPPLY AIR DUCT - TURNING UP OR TOWARD SUPPLY AIR DUCT - TURNING DOWN OR AWAY RETURN OR EXHAUST AIR DUCT - TURNING UP OR TOWARD RETURN OR EXHAUST AIR DUCT - TURNING DOWN OR AWAY ROUND SUPPLY DUCT - TURNING UP OR TOWARD ROUND SUPPLY DUCT - TURNING DOWN OR AWAY ROUND RETURN/EXHAUST DUCT - TURNING UP OR TOWARD ROUND RETURN/EXHAUST DUCT - TURNING DOWN OR AWAY FLEXIBLE CONNECTION VOLUME DAMPER MOTOR OPERATED DAMPER (ELECTRIC OPERATOR SHOWN) 90° ELBOW, R/W OR R/D =1.0 2 ,1.4 90° RECTANGULAR TAKE -OFF WITH 45° TAPER EEEI �� TRANSITION OR REDUCER - NOTED TOP) OR FOB (FLAT ON BOTTOM) IF REQUIRED 4 ACOUSTIC DUCT OR PLENUM 5I I II I I1+1 H+RHS FLEXIBLE DUCT DIFFUSERS AND GRILLES 4 0 } . I"1 ROUND DUCT INDICATOR RECTANGULAR DUCT INDICATOR ROUND DUCT INDICATOR SQUARE CEILING DIFFUSER, PLENUM ATTACHED (FLOW ARROWS SHOWN ONLY IF AIRFLOW NOT SYMMETRICAL) SQUARE CEILING DIFFUSER, WITH ELBOW (FLOW ARROWS SHOWN ONLY IF AIRFLOW NOT SYMMETRICAL) SQUARE CEILING DIFFUSER (FLOW ARROWS SHOWN ONLY IF AIRFLOW NOT SYMMETRICAL) CEILING RETURN/EXHAUST GRILLE (RG/EG) CEILING RETURN GRILLE (RG) CEILING RELIEF GRILLE (RG) WITH ACOUSTICAL DUCT LINED ELBOW OPEN TO CEILING SPACE, REF DETAIL AIRFLOW THRU DOOR GRILLE OR UNDERCUT TRANSFER GRILLE, DUCT CONNECTED, WALL MOUNTED PIPING AND AIRFLOW DIAGRAMS PIPING OR DUCTED AIRFLOW — — — — — — ELECTRICAL CONNECTION XXXX > FLOW CONTINUATION ARROW _ _ _ —d CONNECTION TO CENTRAL MONITORING AND CONTROL SYSTEM (CMCS) PIPING FITTINGSNALVES ID I0 ICI —O FCO --II CO WCO --I 0 I --- PIPING TYPES PIPE DOWN PIPE UP TEE DOWN TEE FLOOR CLEANOUT CLEANOUT WALL CLEANOUT PIPE CAP UNION BALL VALVE D TP DRAIN (INDIRECT) SANITARY WASTE SANITARY VENT TRAP PRIMER COLD WATER (CW) HOT WATER (HW) HOT WATER CIRCULATING (HWC) A AFF AHU AMU ARCH ATM AVG BHP BTUH CAP CFM CH CLG CNDS CO COND CONT CONTR CP CU CU FT CV DB DIA DISCH DMPR DN DWG EA EF ELEC ENT EXH FCO FD FLR FLTR FS FT GAL GALV GPM HB HC HD HP ID IEER IN IPLV KW KWH LAT LVG MAX MBH MCA MECH MIN MOD NO NPLV NTS OA OD OPNG PG POC PSI PSIG PSID PVC RA RF RO RPBA RPM SA SEER SF SP SPKR SS S/S STRUC TYP UH V VA VAV VTR W WB WCO WG WH WSEC AIR, AMP ABOVE FINISHED FLOOR AIR HANDLING UNIT AIR FLOW MEASURING UNIT ARCHITECT/ARCHITECTURAL ATMOSPHERE AVERAGE BRAKE HORSEPOWER BRITISH THERMAL UNIT PER HOUR COMMON CAPACITY CUBIC FEET PER MINUTE CABINET HEATER CEILING, COOLING CONDENSATE CLEANOUT CONDENSER CONTINUE, CONTINUATION CONTRACTOR CIRCULATING PUMP COPPER CUBIC FOOT CONSTANT VOLUME DRY BULB DIAMETER DISCHARGE DAMPER DOWN DRAWING EXHAUST AIR EXHAUST FAN ELECTRICAL ENTERING EXHAUST FAHRENHEIT FLOOR CLEANOUT FIRE DAMPER, FLOOR DRAIN FLOOR FILTER FLOOR SINK FEET, FAN TERMINAL GALLONS GALVANIZED GALLONS PER MINUTE HOSE BIBB HEATING COIL HEAD HORSEPOWER, HEAT PUMP INSIDE DIAMETER INTEGRATED ENERGY EFFICIENCY RATIO INCHES INTEGRATED PART LOAD VALUE KILOWATT KILOWATT HOUR LEAVING AIR TEMPERATURE LEAVING MAXIMUM THOUSAND BTU PER HOUR MINIMUM CIRCUITAMPACITY MECHANICAL MINIMUM MOTOR OPERATED DAMPER NUMBER, NORMALLY OPEN NON-STANDARD PART LOAD VALUE NOT TO SCALE OUTDOOR AIR OUTSIDE DIAMETER OPENING PROPYLENE GLYCOL POINT OF CONNECTION POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GUAGE POUNDS PER SQUARE INCH DIFFERENTIAL POLYVINYL CHLORIDE RETURN AIR/RELIEF AIR RETURN FAN RETURN OPENING REDUCED PRESSURE BACKFLOW ASSEMBLY REVOLUTIONS PER MINUTE SUPPLY AIR SEASONAL ENERGY EFFICIENCY RATIO SUPPLY FAN STATIC PRESSURE SPRINKLER STAINLESS STEEL, SANITARY SEWER START/STOP STRUCTURAL TYPICAL UNIT HEATER VENT, VOLT VALVE VARIABLE AIR VOLUME VENT THRU ROOF WASTE, WATT WET BULB WALL CLEANOUT WATER GAGE WATER HEATER, WALL HYDRANT WASHINGTON STATE ENERGY CODE SEPARATE PERMIT RED ReEcD, FOR: �_, Manocai Electrical P., Plumbing LI2 Gas Piping City of Tukwila UILDING DIVISION FILE Tit, No. F1��u�t�0 Ysan reyew approval is subject to errors ono rn ssrons Approval of construction documents noes 'u^t authorize Ire voiat•'on o^ any adopted code or ardlnance Receo, p approved r,ep Copy and "-'congtuo s, ae naw;eddec Date 3 fie SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 BURGESS DESIGN INTERIORS ARCHITECTURE All reproduction s Intellectual property tights maenad c 2017 Wod Haorbinger qao io8th Ave NE, Suite moo Bellevue, WA 9800y 25.628.6000 woodharbingeccom Professional seal No. issue Description Date REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City Electronic Stamp Location CITY OF 'I L,:1V'LA OCT 18 2019 ?ERnIT CENTER 6 Drown by: MK Project Manager: RM eject No: 19.0168.00 MECHANICAL SYMBOLS & ABBREVIATIONS drosig M 24' x 36'. Soots antltlo 000adMtgy N retMrad atr► m.0.1 GRILLES AND DIFFUSERS SCHEDULE MARK NUMBER A B C D E F G SERVICE CEILING SUPPLY CEILING SUPPLY CEILING RETURN RETURN GRILLE CEILING RETURN CEILING TRANSFER CEILING TRANSFER TYPE HARD LID HARD LID HARD LID DUCT MOUNTED HARD LID HARD LID HARD LID SERVICE CONDITIONS CAPACITY-CFM 201-400 75-200 100-350 100-350 351-500 501-1200 501-1200 NOISE CRITERIA -MAX NC LEVEL 23 28 < 10 < 10 22 21 35 PRESS DROP -INCHES WG MAX 0.06 0.12 < 0.01 < 0.01 0.02 0.04 0.05 THROW -FT 13 10 - - - - - FLOW PATTERN [1] [1] - - - _ _ UNIT SIZE -INCHES NOMINAL FACE 24x24 12x12 12x10 12x10 24x24 24x12 24x24 NECK-DIA OR WxH 10 8 6x6 6x6 12 22x10 16 BRANCH DUCT SIZE -INCHES (DIA OR WxH) 10 8 8 8 12 10 16 STANDARD OF ACCEPTANCE MANUFACTURER TITUS TITUS TITUS TITUS TITUS TITUS TITUS MODEL MCD MCD 50F 50F PAR PAR PAR REMARKS [1] FIELD ADJUST DIFFUSER AIRFLOW THROW PATTERN AS SHOWN ON FLOOR PLAN. [2] SEE SHEET M.5.1 FOR DIFFUSER AND GRILLE DETAILS. DOMESTIC WATER HEATER - ELECTRIC EQUIPMENT NUMBER WH-1 SYSTEM DOMESTIC HW UNIT LOCATION JANITOR CLOSET STORAGE CAPACITY -GALLONS 30 SERVICE CONDITIONS ENT WATER TEMP -DEG F 60 LVG WATER TEMP RANGE -DEG F 110-120 RECOVERY- GAL PER HOUR AT 100 DEG F 41 ELECTRICAL VOLTS -PHASE -HERTZ 480-3-60 CAPACITY -kW 6 DESIGN BASIS MAKE RHEEM MODEL EGSP3O MAX OPERATING WEIGHT-LBS 115 EXPANSION TANK EQUIPMENT NUMBER ET-1 SYSTEM DOMESTIC HOT WATER UNIT LOCATION JANITOR TYPE DIAPHRAGM TANK CONDITIONS CAPACITY -GALLONS 2.0 ACCEPTANCE -GALLONS 0.9 CHARGE-PSIG 65.0 CONFIGURATION VERTICAL RATING ASME TANK SIZE MAX DIAMETER -INCHES 8 MAX LENGTH -INCHES 13 DESIGN BASIS MAKE AMTROL MODEL ST-5 MAX OPERATING WEIGHT-LBS 15 GENERAL NOTES: THE FOLLOWING NOTES APPLY TO ALL MECHANICAL, PLUMBING, AND FIRE PROTECTION DRAWINGS. ADDITIONAL NOTES MAY BE INDICATED ON INDIVIDUAL DRAWINGS. 2. DRAWINGS INDICATE CONNECTIONS FOR EQUIPMENT TO BE FURNISHED BY THE OWNER OR AS THE WORK OF OTHER TRADES. VERIFY LOCATION OF EQUIPMENT, ROUGH -IN LOCATIONS, AND TYPE OF CONNECTIONS PRIOR TO PREPARATION OF SHOP DRAWINGS OR SUBMITTALS, AND PRIOR TO INSTALLATION OF SERVICE CONNECTIONS. DO NOT INTERFERE WITH ACCESS FOR MAINTENANCE AND REMOVAL OR REPLACEMENT OF EQUIPMENT. 3. COORDINATE THE PHASING AND INSTALLATION OF NEW WORK WITH THE WORK OF ALL OTHER TRADES. BEAR THE TOTAL EXPENSE FOR ANY ADDITIONAL WORK WHICH MAY BE CAUSED BY IMPROPER SEQUENCING OF CONSTRUCTION ACTIVITIES. 4. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS OF DEVICES IN FINISHED AREAS. LOCATE PLUMBING FIXTURES AT HEIGHTS INDICATED ON ARCHITECTURAL ELEVATIONS. LOCATE MECHANICAL DEVICES (E.G. TEMPERATURE AND HUMIDITY SENSORS, PANELS, AND SWITCHES), SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (E.G. WAINSCOT, DOOR HARDWARE), ELECTRICAL DEVICES (E.G. LIGHT SWITCHES, SPEAKERS, OUTLETS), AND THE WORK OF OTHER TRADES. 5. REFER TO ARCHITECTURAL FOR GENERAL CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, PENETRATION DETAILS, FLASHING AND SEALING DETAILS, AND OTHER ELEMENTS OF GENERAL CONSTRUCTION. 6. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF CEILING MOUNTED ITEMS. INSTALL CEILING MOUNTED ITEMS IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE INDICATED ON ARCHITECTURAL DRAWINGS. WHERE LOCATION OF ITEMS ARE NOT INDICATED ON ARCHITECTURAL DRAWINGS, OBTAIN DIRECTION FROM ARCHITECT PRIOR TO ROUGH -IN AND INSTALLATION. 7. COORDINATE EQUIPMENT POWER CONNECTION REQUIREMENTS AND ELECTRICAL CHARACTERISTICS WITH ELECTRICAL DRAWINGS AND CONNECTION REQUIREMENTS. COORDINATE VARIATION IN ELECTRICAL CHARACTERISTICS FROM SCHEDULED VALUES. CHANGES TO ELECTRICAL CHARACTERISTICS (E.G. VOLTAGE, AMPS, HORSEPOWER, ETC.) SHALL BE SUBJECT TO APPROVAL. BEAR THE TOTAL EXPENSE FOR REQUIRED REVISION TO THE ELECTRICAL SCOPE OF WORK CAUSED BY VARIATION FROM THE SCHEDULED REQUIREMENTS. 8. EQUIPMENT SHORT CIRCUIT CURRENT RATINGS (SCCR) SHALL BE NOT LESS THAN THE INTERRUPTING RATING OF THE BRANCH CIRCUIT OVER CURRENT PROTECTIVE DEVICE SUPPLYING POWER TO THE EQUIPMENT. REFER TO ELECTRICAL SCHEDULES FOR BRANCH CIRCUIT OVER CURRENT DEVICE INTERRUPTING RATINGS. 9. COORDINATE THE LOCATION OF WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES AND OTHER CEILING MOUNTED DEVICES AS REQUIRED TO ALLOW FOR REMOVAL AND MAINTENANCE ACCESS. 10. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES, DUCTS, AND EQUIPMENT AS SPECIFIED, AS REQUIRED, AND AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, DESIGN AND PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT AND SEISMIC RESTRAINT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS AND ANCHORAGES SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN WASHINGTON STATE. 11. COORDINATE THE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES SO THAT IT FITS INTO THE SPACE ALLOTTED. PROVIDE SERVICE ACCESS AND CLEARANCES AS INDICATED ON DRAWINGS, AS REQUIRED BY CODES, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE INSTALLATION, REMOVAL, ENTRY, SERVICING, AND MAINTENANCE OF EQUIPMENT. PRIOR TO INSTALLATION, COORDINATE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES WITH ALL OTHER TRADES TO AVOID BLOCKING SERVICE OR REPLACEMENT ACCESS FOR NEW AND EXISTING EQUIPMENT AND EQUIPMENT INSTALLED BY OTHERS. 12. DRAWINGS ARE DIAGRAMMATIC AND SHOW APPROXIMATE LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES. DRAWINGS DO NOT SHOW REQUIRED TRANSITIONS, OFFSETS, FITTINGS, AND DEVICES. REFER TO DETAILS, DIAGRAMS, AND SPECIFICATIONS FOR REQUIRED SYSTEM APPURTENANCES, CONTROL DEVICES, ETC. INSTALL DEVICES IN ACCORDANCE WITH DEVICE MANUFACTURER RECOMMENDATIONS. CAREFULLY INVESTIGATE ELEMENTS OF CONSTRUCTION THAT COULD AFFECT THE WORK TO BE PERFORMED AND ARRANGE NEW WORK ACCORDINGLY. PREPARE COORDINATION DRAWINGS FOR NEW WORK, WHICH ARE COORDINATED WITH THE APPROVED AND INSTALLED WORK OF OTHER TRADES. PROVIDE REQUIRED OFFSETS, FITTINGS, TRANSITIONS, SUPPORTS AND OTHER APPURTENANCES AS REQUIRED. BEAR THE TOTAL EXPENSE OF RE -WORK THAT IS CAUSED BY FAILURE TO COORDINATE. 13. PROVIDE MAXIMUM HEADROOM AND CLEARANCE BELOW DUCTWORK, PIPING AND EQUIPMENT AND ASSOCIATED SUPPORTS AND RESTRAINTS. UNLESS OTHERWISE INDICATED, INSTALL TIGHT TO STRUCTURAL SYSTEMS ABOVE. WHERE WALL MOUNTED, INSTALL AS CLOSE TO WALLAS POSSIBLE. PROVIDE ADDITIONAL FITTINGS AND OFFSETS AS REQUIRED. 14. REFER TO EQUIPMENT SCHEDULES FOR DESIGN CAPACITIES. SCHEDULED VALUES SHALL BE CONSIDERED DESIGN CAPACITIES. PROVIDE EQUIPMENT WHICH MEETS OR EXCEEDS THE SCHEDULED VALUES. MARK THE CONTRACT DRAWING EQUIPMENT SCHEDULES TO INDICATE THE MANUFACTURER, MODEL AND CAPACITY OF THE ACTUAL APPROVED EQUIPMENT PROVIDED AND SUBMIT THIS INFORMATION WITH RECORD DRAWINGS AS PART OF PROJECT CLOSEOUT. 15. TO ENHANCE THE CLARITY OF PLAN DRAWINGS, AND WHERE NOT NECESSARY TO DESCRIBE THE REQUIRED SIZE, INDIVIDUAL SEGMENTS OF DUCT AND PIPE BETWEEN CONNECTIONS MAY BE SHOWN WITHOUT A SIZE INDICATED. WHERE SIZE IS NOT SHOWN ON PLANS, THAT SEGMENT SHALL BE THE SAME SIZE AS THE NEXT UPSTREAM SEGMENT WITH A SIZE INDICATED. 16. WHERE NOT INDICATED ON PLANS, REFER TO EQUIPMENT SCHEDULES AND DETAILS FOR INLET AND OUTLET DUCT AND/OR PIPE SIZES. WHERE INDICATED ON PLANS, PLAN SIZES SHALL TAKE PRECEDENCE. 17. DUCTWORK SERVING INDIVIDUAL DIFFUSERS AND GRILLES IS GENERALLY NOT SIZED. WHERE NOT INDICATED ON PLAN DRAWINGS, REFER TO SCHEDULES AND DETAILS FOR NECK AND BRANCH DUCT SIZES BASED ON INDICATED AIRFLOW RATE OR NECK SIZE. 18. INSTALL DRAINS AT ALL LOW POINTS IN PIPING, INCLUDING ANY TRAPPED PORTIONS OF PIPING. INDICATE THE ACTUAL LOCATION OF FIELD -LOCATED DRAINS, VENTS AND DRAIN PIPING ON THE RECORD DRAWINGS. 19. PROVIDE A MANUAL VOLUME DAMPER FOR EACH SUPPLY, RETURN, AND EXHAUST OPENING, IN ALL BRANCH DUCTS WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH BRANCH, AND ELSEWHERE AS NOTED ON DRAWINGS OR IN SPECIFICATIONS. LOCATE VOLUME DAMPERS AS FAR AS POSSIBLE FROM OPENINGS. FOR THE PURPOSE OF THIS REQUIREMENT, TERMINAL UNIT PRIMARY AIR DAMPERS ARE CONSIDERED A VOLUME DAMPER. VOLUME DAMPERS ARE NOT REQUIRED FOR CEILING RETURN GRILLES THAT TRANSFER AIR TO A RETURN AIR PLENUM UNLESS OTHERWISE INDICATED. 20. PROVIDE CONICAL TAPS FOR 90 DEGREE ROUND DUCT BRANCHES FROM RECTANGULAR SUPPLY DUCTWORK. DO NOT USE STRAIGH TEE FITTINGS UNLESS SPECIFICALLY INDICATED ON DRAWINGS. 21, DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED ON SMACNA HDCS: DUCT SYSTEM STATIC PRESSURE SEAL CLASS A. UPSTREAM OF TERMINAL UNITS PLUS 4" A B. DOWNSTREAM OF TERMINAL UNITS MINUS 2" C C. UPSTREAM OF RETURN OR EXHAUST FANS PLUS 4" C 22. THE FOLLOWING IS A LIST OF DEFERRED SUBMITTALS ITEMS. DO NOT INSTALL DEFERRED SUBMITTAL ITEMS UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. A. SEISMIC B. FIRE PROTECTION SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 B BURGESS DESIGN I N T E R I O R S ARCHITECTURE AN reproduction a kri.l.otnd pop.riy right. rowed o 2017 Wood Harbinger 929 io8th Ave NE, Suite loop Bellevue, WA 9800y 425.628.6000 woodha rbinger. cam Professional seal No. Issue Description Dote REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 txty Electronic Stomp vocation Drawn by: MK Project Morwger: RM OCT 2: 2019 Project No: 19.0109 00 City of Tukwila BUILD '4 DIV Si01� MECHANICAL jt�i� SCHEDULES & GENERAL CITYnEccPF 'i.FiL:79,i:LA NOTES OCT 18 2019 PERMIT CENTER 0r1001 awing 124' x 36'. Sod..006. 000adingy If Woad "- CODE C':s .` Li lGE APP< O< D M.0.2 PLUMBING AND HVAC SPECIFICATIONS PART 1 -GENERAL 1. GENERAL PROVISIONS: DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF WORK IN CONTRACT. 2. SCOPE: PERFORM WORK AND PROVIDE NEW MATERIAL AND EQUIPMENT AS SHOWN ON DRAWINGS AND AS SPECIFIED IN THIS SECTION OF THE SPECIFICATIONS. PROVIDE ALL COMPONENTS AND MATERIALS, WHETHER SPECIFICALLY SHOWN OR NOT, THAT ARE NECESSARY TO MAKE THE SYSTEMS COMPLETE AND FULLY OPERATIONAL AS INTENDED IN THE CONSTRUCTION DOCUMENTS. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO: 1) THE DESIGN INTENT AS ILLUSTRATED ON THESE DRAWINGS, 2) ALL TESTING AND CERTIFICATIONS NECESSARY FOR COMPLIANCE INCLUDING ANY REQUIRED REMEDIAL ACTIONS AND RETESTING DUE TO FAILURE. 3. SITE VISIT: VISIT AND CAREFULLY EXAMINE SITE TO IDENTIFY EXISTING CONDITIONS THAT MAY AFFECT WORK OF THIS SECTION BEFORE SUBMITTING BID. NO EXTRA PAYMENT WILL BE ALLOWED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY DISCERNED BY AN EXPERIENCED OBSERVER. 4. CODES, PERMITS, INSPECTIONS, AND FEES: CONFORM TO REQUIREMENTS OF DIVISION 01. OBTAIN PERMITS AND INSPECTIONS AND PAY FEES REQUIRED BY NATIONAL, STATE AND LOCAL AUTHORITIES. MAKE ARRANGEMENTS FOR INSPECTIONS BY ARCHITECT, OWNER OR OTHER AUTHORITY AS REQUIRED. SUBMIT 3 COPIES OF CERTIFICATES OF COMPLIANCE TO ARCHITECT. WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF LATEST ADOPTED EDITION OF APPLICABLE CODES, REGULATIONS, ORDINANCES, AND LOCAL AMENDMENTS INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING. NOTHING IN DRAWINGS AND SPECIFICATIONS SHALL BE CONSTRUED TO PERMIT WORK NOT IN CONFORMANCE WITH THESE RULES AND REGULATIONS. a) INTERNATIONAL BUILDING CODE. b) INTERNATIONAL MECHANICAL CODE. c) INTERNATIONAL FIRE CODE. d) UNIFORM PLUMBING CODE. e) WASHINGTON STATE ENERGY CODE. 0 NATIONAL ELECTRICAL CODE. g) STATE OF WASHINGTON STANDARDS, WAC_296_24, GENERAL SAFETY AND HEALTH STANDARDS. h) NFPA 13, SPRINKLER SYSTEMS. i) NFPA 90A, INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS. j) AMERICAN NATIONAL STANDARD CODE FOR PRESSURE PIPING, CHAPTER V (ANSI B31.1). k) WASHINGTON BOILERS AND UNFIRED PRESSURE VESSEL LAWS, RCW 70.79 AND WAC 296, CHAPTER 104, AS PUBLISHED BY WASHINGTON STATE DEPARTMENT OF LABOR AND INDUSTRIES, DIVISION OF BOILER INSPECTION. I) AMERICANS WITH DISABILITIES ACT (ADA). m) PUGET SOUND AIR POLLUTION CONTROL AGENCY. 6. INTERPRETATIONS OF DOCUMENTS: WHERE DRAWINGS OR SPECIFICATIONS DO NOT COINCIDE WITH MANUFACTURER'S RECOMMENDATIONS, OR ARE UNCLEAR AS TO INTENT, OR REQUIRED MATERIAL QUALITY, ADVISE THE ENGINEER IN WRITING BEFORE PROCEDING WITH THE WORK. ALL COST FOR REWORK NECESSARY TO RESOLVE DISCREPANCIES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 7. REQUESTS FOR INFORMATION: ANY RFI FOR RESOLVING AN APPARANT CONFLICT OR UNCLARITY, OR A REQUEST FOR ADDITIONAL DETAIL, SHALL INCLUDE A SKETCH OR EQUIVALENT DESCRIPTION OF CONTRACTOR'S PROPOSED SOLUTION. 8. SUBMITTALS: PROVIDE SPECIFIED ITEMS AND EQUIPMENT UNLESS "EQUAL" OR "APPROVED EQUAL" IS EXPLICITLY INDICATED ON THE DRAWINGS. DEVIATIONS TO SPECIFIED ITEMS SHALL BEAT THE SOLE RISK OF THE CONTRACTOR, WHO SHALL BE RESPONSIBLE FOR ALL ASSOCIATED CHANGES TO THIS AND OTHER TRADES. REVIEW OF THE SHOP DRAWINGS BY THE ENGINEER SHALL NOT ABSOLVE THE CONTRACTOR FROM MEETING THE FULL DESIGN INTENT OF THE ASSOCIATED SYSTEM(S). SUBMITTALS SHALL INDICATE PRIOR REVIEW AND APPROVAL BY THE RESPONSIBLE CONTRACTOR. SUBMIT FOR REVIEW MANUFACTURER'S PRODUCT DATA FOR THE FOLLOWING ITEMS: 1) AIR DISTRIBUTION LAYOUT DRAWINGS AND DETAILS, 2) PIPING DISTRIBUTION LAYOUT DRAWINGS, COMPONENTS, AND DETAILS, 3) ALL EQUIPMENT, 4) CONTROL SCHEMATICS, COMPONENTS, AND SEQUENCES, INCLUDING TIE -INTO THE EXISTING BUILDING CONTROL OR MANAGEMENT SYSTEM, 5) BALANCING REPORTS, 6) ALL TEST REPORTS, AND 7) ALL CERTIFICATES. ALLOW ENGINEER A MINIMUM OF 10 WORKING DAYS FOR PROCESSING AND REVIEW OF EACH SUBMISSION. 9. OPERATION AND MAINTENANCE DATA: SUBMIT (3) SETS OF OPERATING AND MAINTENANCE MANUALS PRIOR TO THE COMPLETION OF THE PROJECT, PROVIDE ON -SITE DEMONSTRATION OF ALL SYSTEMS TO OWNER AFTER SYSTEMS ARE FULLY OPERATIONAL. 0&M MANUALS SHALL INCLUDE ALL COMPONENTS (DIFFUSERS, VALVES, ETC.) AS WELL AS SYSTEM DESCRIPTIONS OF ALL SYSTEMS WITH FLOW DIAGRAMS, WIRING DIAGRAMS, WRITTEN WARRANTEES, RECOMMENDED SPARE PARTS AND ROUTINE MAINTENANCE REQUIREMENTS WITH RECOMMENDED INTERVALS FOR ALL MOVING EQUIPMENT AND CONTROLS. 10. RECORD DRAWINGS: CAD RECORD DRAWING FILES SHALL BE SUBMITTED AT THE COMPLETION OF THE PROJECT SHOWING THE "AS -BUILT" CONDITION INCLUDING WORK INSTALLED AND ALL MODIFICATONS OR ADDITIONS TO ORIGINAL DESIGN. OBTAIN THE AUTOCAD FILES FOR PREPARATION OF AS -BUILT DRAWINGS FROM THE ARCHITECT. THE ARCHITECT AND ENGINEER ARE NOT GRANTING ANY OWNERSHIP OR PROPERTY INTEREST IN THE CAD DRAWINGS BY THE DELIVERY OF THE CAD FILES. THE USE OF THE CAD FILES AND DRAWINGS ARE LIMITED FOR THE SOLE PURPOSE OF ASSISTING IN THE CONTRACTOR'S PERFORMANCE IN ITS CONTRACTUAL OBLIGATIONS WITH RESPECT TO THIS PROJECT. ANY REUSE AND/OR OTHER USE BY THE CONTRACTOR WILL BE AT THE CONTRACTOR'S SOLE RISK AND WITHOUT LIABILITY TO THE ARCHITECT AND ENGINEER. RECORD DOCUMENTS SHALL CONFORM TO REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE 11. WARRANTIES: WARRANTY INSTALLATION IN WRITING FOR ONE YEAR FROM DATE OF OWNER'S ACCEPTANCE OF CERTIFICATE OF SUBSTANTIAL COMPLETION. WHERE INDIVIDUAL EQUIPMENT SECTIONS SPECIFY LONGER WARRANTEES, PROVIDE THE LONGER WARRANTEE. REPAIR, REPLACE OR PROVIDE TEMPORARY ACCOMMODATIONS FOR DEFECTIVE MATERIALS, EQUIPMENT, WORKMANSHIP AND INSTALLATION THAT DEVELOP WITHIN 24 HOURS OF NOTIFICATION. WARRANTY SHALL INCLUDE A CONTACT PERSON (NAME AND 24 HOUR TELEPHONE NUMBER) FOR SERVICE REQUESTS. CORRECT DAMAGE CAUSED WHILE MAKING NECESSARY REPAIRS AND REPLACEMENTS UNDER WARRANTY PERIOD AT NO ADDITIONAL COST. 12. COORDINATION: CONFER WITH ALL OTHER TRADES RELATIVE TO LOCATION OF ALL APPARATUS AND EQUIPMENT TO BE INSTALLED AND SELECT LOCATIONS SO AS NOT TO CONFLICT WITH OR HINDER THE PROGRESS OF THE WORK OF OTHER SECTIONS. WORK INSTALLED THAT CREATES INTERFERENCE OR RESTRICTS ACCESS REQUIRED BY CODE (INCLUDING CLEARANCES TO ELECTRICAL COMPONENTS) OR TO CONDUCT MAINTENANCE ANDIOR ADJUSTMENTS SHALL BE MODIFIED AT NO ADDITIONAL COST TO THE OWNER. 13. SUPPORTS: INCLUDE ALL STRUCTURAL STEEL SUPPORTS, HANGER BRACKETS, ETC., REQUIRED FOR THE EXECUTION OF THE WORK OF THIS SECTION. THE WELDS AND EDGES OF ALL BRACKETS SHALL BE FILED OR GROUND SMOOTH FOR PAINTING. HANGERS SHALL BE STEEL ANGLE IRON, CHANNEL OR STEEL ROD USED WITH APPROVED CLAMPS, INSERTS, ETC. ALL HANGERS SHALL BE GALVANIZED OR PAINTED WITH TWO COATS OF CORROSION RESISTANT PAINT BEFORE INSTALLATION. APPLY TOUCH-UP PAINT (ZINC GALVANIZING FOR GALVANIZED STEEL) AFTER INSTALLATION. 14, CUTTING AND PATCHING: INCLUDE ALL CORING, CUTTING, PATCHING AND FIREPROOFING NECESSARY FOR THE EXECUTION OF THE WORK OF THIS SECTION. STRUCTURAL ELEMENTS SHALL NOT BE CUT WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ALL PRECAUTIONS REQUIRED TO IDENTIFY HIDDEN PIPING, CONDUITS, WIRING, ETC. BEFORE ANY CORE DRILLING, AND/OR CUTTING OF SLABS COMMENCES, INCLUDING X-RAYING THE AFFECTED SLABS. REPAIR AND PATCH AROUND THE WORK SPECIFIED HEREIN TO MATCH THE EXISTING ADJACENT SURFACES TO THE SATISFACTION OF THE ARCHITECT. FILL AND PATCH ALL OPENINGS OR HOLES LEFT IN THE EXISTING STRUCTURES BY THE REMOVAL OF EXISTING EQUIPMENT THAT IS PART OF THIS SECTION OF THE SPECIFICATIONS. PATCH AND SEAL ALL EXISTING OPENINGS IN DUCTWORK AND PIPING NOT UTILIZED FOR NEW LAYOUT. PROVIDE FIRE STOPPING TO MAINTAIN THE FIRE RATING OF THE FIRE RESISTANCE -RATED ASSEMBLY. ALL PENETRATIONS AND ASSOCIATED FIRE STOPPING SHALL BE INSTALLED IN ACCORDANCE WITH THE FIRE STOPPING MANUFACTURER'S LISTED INSTALLATION DETAILS AND BE LISTED BY UL OR FM. 15. HOISTING, SCAFFOLDING AND PLANKING: INCLUDE THE FURNISHING, SET-UP AND MAINTENANCE OF ALL HOISTING MACHINERY, CRANES, SCAFFOLDS, STAGING AND PLANKING AS REQUIRED FOR THE EXECUTION OF WORK FOR THIS SECTION. 16. SAFETY PRECAUTIONS: LIFE SAFETY AND ACCIDENT PREVENTION SHALL BE A PRIMARY CONSIDERATION. COMPLY WITH ALL OF THE SAFETY REQUIREMENTS OF THE OWNER AND OSHA THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD OF THE PROJECT. FURNISH, PLACE AND MAINTAIN PROPER GUARDS AND ANY OTHER NECESSARY CONSTRUCTION REQUIRED TO SECURE SAFETY OF LIFE AND PROPERTY. 17. ACCESSIBILITY: ALL WORK PROVIDED UNDER THIS SECTION OF THE SPECIFICATION SHALL BE INSTALLED SO THAT PARTS REQUIRING PERIODIC INSPECTION, MAINTENANCE AND REPAIR ARE READILY ACCESSIBLE. WORK OF THIS TRADE SHALL NOT INFRINGE UPON CLEARANCES REQUIRED BY EQUIPMENT OF OTHER TRADES. 18, PROTECTION OF WORK AND PROPERTY: CONTRACTOR SHALL BE RESPONSIBLE FOR THE CARE AND PROTECTION OF ALL WORK INCLUDED UNDER THIS SECTION UNTIL THE COMPLETION AND FINAL ACCEPTANCE OF THIS PROJECT. PROTECT ALL EQUIPMENT AND MATERIALS FROM DAMAGE FROM ALL CAUSES INCLUDING, BUT NOT LIMITED TO, FIRE, VANDALISM AND THEFT, ALL MATERIALS AND EQUIPMENT DAMAGED OR STOLEN SHALL BE REPAIRED OR REPLACED WITH EQUAL MATERIAL OR EQUIPMENT AT NO ADDITIONAL COST TO THE OWNER, PROTECT ALL EQUIPMENT, OUTLETS AND OPENINGS, AND ROOF PENETRATIONS WITH TEMPORARY PLUGS, CAPS AND COVERS. PROTECT WORK AND MATERIALS OF OTHER TRADES FROM DAMAGE THAT MIGHT BE CAUSED BY WORK OR WORKMEN UNDER THIS SECTION AND MAKE GOOD DAMAGE THUS CAUSED. DAMAGED MATERIALS ARE TO BE REMOVED FROM THE SITE; NO SITE STORAGE OF DAMAGED MATERIALS WILL BE ALLOWED. ANY DAMAGE TO EXISTING SYSTEMS AND EQUIPMENT CAUSED BY THE CONTRACTOR DURING INSTALLATION SHALL BE REPAIRED AND/OR REPLACED AT THE CONTRACTOR'S EXPENSE TO THE COMPLETE SATISFACTION OF THE BUILDING OWNER. 19. SEISMIC RESTRAINT REQUIREMENTS: PROVIDE SEISMIC RESTRAINTS AS REQUIRED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. A REGISTERED PROFESSIONAL STRUCTURAL ENGINEER, LICENSED IN THE STATE OF WASHINGTON, SHALL PREPARE THE SEISMIC RESTRAINT DESIGN AND CERTIFY THAT THE DESIGN IS IN COMPLIANCE WITH THE INTERNATIONAL BUILDING CODE REQUIREMENTS. PART 2-PRODUCTS 1. PLUMBING: PIPE, TUBE, FITTINGS, VALVES, EXPANSION TANKS, SUPPLY TANKS, INTERIOR TANK COATINGS, TANK LINERS, SOLVENT CEMENTS, THREAD SEALANTS, SOLDERS, AND FLUX USED IN POTABLE WATER SYSTEMS INTENDED TO SUPPLY DRINKING WATER SHALL COMPLY WITH REQUIREMENTS OF NSF 61. THE MAXIMUM ALLOWABLE LEAD CONTENT IN PIPES, PIPE FITTINGS, PLUMBING FITTINGS, AND FIXTURES INTENDED TO CONVEYOR DISPENSE WATER FOR HUMAN CONSUMPTION SHALL BE NOT MORE THAN A WEIGHTED AVERAGE OF 0.25 PERCENT WITH RESPECT TO THE WETTED SURFACES OF PIPES, PIPE FITTINGS, PLUMBING FITTINGS, AND FIXTURES. FOR SOLDER AND FLUX, THE LEAD CONTENT SHALL BE NOT MORE THAN 0.2 PERCENT WHERE USED IN PIPING SYSTEMS THAT CONVEYOR DISPENSE WATER FOR HUMAN CONSUMPTION. SUBMIT DOCUMENTATION. 2. PIPES, PIPE FITTINGS, AND VALVES UTILIZED IN THE WATER SUPPLY SYSTEM FOR NON_DRINKING WATER APPLICATIONS SHALL HAVE A MAXIMUM OF 8 PERCENT LEAD CONTENT. 3. DOMESTIC COLD WATER, DOMESTIC HOT WATER PIPING, DOMESTIC HOT WATER CIRCULATING PIPING: PIPING SHALL BE ASTM B88 TYPE L, HARD DRAWN COPPER. FITTINGS AND UNIONS SHALL BE WROUGHT COPPER SOLDER WITH THREADED ADAPTERS, ANSI B16.22. FLANGES AND FLANGED FITTINGS SHALL BE FLAT FACE, CAST BRONZE, 125 PSIG CLASS, ASME STANDARDS. JOINT COMPOUND FOR 1" AND SMALLER SHALL BE POLYTETRAFLUOROETHYLENE (PTFE) PIPE THREAD TAPE CONFORMING TO REQUIREMENTS OF ASTM D3308; SHALL COMPLY WITH REQUIREMENTS OF NSF 61. JOINT COMPOUND FOR 1-114" AND LARGER SHALL BE LEAD FREE, NON TOXIC, NON HARDENING, PIPE JOINT COMPOUND SHALL COMPLY WITH REQUIREMENTS OF NSF 61 AND FEDERAL SPECIFICATION TT S 1732. SOLDER SHALL BE 95 PERCENT TIN, 5 PERCENT ANTIMONY AND COMPLY WITH REQUIREMENTS OF NSF 61. 4. DOMESTIC WATER VALVES: ALL VALVES MUST COMPLY WITH NSF 61. ACCEPTABLE VALVE MANUFACTURERS: MUELLER, NIBCO, APOLLO, OR APPROVED EQUAL. CHECK VALVES SHALL BE TYPE 3 OR TYPE 4 CONFORMING TO REQUIREMENTS OF MSS SP 80 OR MSS SP 139; CAST SILICON BRONZE BODY CONFORMING TO REQUIREMENTS OF ASTM B584; BRONZE OR POLYTETRAFLUOROETHYLENE (PTFE) DISC; THREADED END CONNECTIONS CONFORMING TO REQUIREMENTS OF ASME B1.20.1; SCREWED CAP, Y PATTERN, SWING DISC; RENEWABLE SEAT AND DISC; MINIMUM PRESSURE RATING OF 150 PSIG AT 230 DEGREES F. BALL VALVES SHALL BE TWO PIECE BODY CONFORMING TO REQUIREMENTS OF MSS SP 110; FULL PORT; SOLID BALL; CAST SILICON BRONZE BODY CONFORMING TO REQUIREMENTS OF ASTM B584; THREADED END CONNECTIONS CONFORMING TO REQUIREMENTS OF ASME B1.20.1; POLYTETRAFLUOROETHYLENE (PTFE) SEAT; MINIMUM PRESSURE RATING OF 150 PSIG AT 230 DEGREES F. BUTTERFLY VALVES SHALL BE CLASS 125 FLANGED CONNECTIONS CONFORMING TO REQUIREMENTS OF ASME B16,1 OR GROOVED END STYLE; DUCTILE IRON BODY AND DISC CONFORMING TO REQUIREMENTS OF ASTM A395 OR ASTM A536 GRADE 65 45 12; BUBBLE TIGHT TO 150 PSI; ACCEPTABLE MANUFACTURERS: VICTAULIC, NIBCO, WATTS, OR APPROVED EQUAL. 5. SANITARY WASTE PIPING AND SANITARY VENT PIPING: STANDARD WEIGHT BELL AND SPIGOT CAST IRON PIPE PER ASTM A74, WITH NEOPRENE COMPRESSION SEAL PER ASTM C564; LONG PATTERN CAST IRON DRAINAGE FITTINGS. STANDARD WEIGHT HUBLESS CAST IRON PIPE AND FITTINGS PER CISPI 301; NEOPRENE SLEEVE GASKET WITH STAINLESS STEEL SHIELD AND BAND; LONG PATTERN CAST IRON DRAINAGE FITTINGS. COUPLING SHALL CONFORM TO CISPI 310. 6. INDIRECT DRAIN PIPING: TYPE DWV, ASTM B306. FITTINGS SHALL BE TYPE DWV WROUGHT COPPER DRAINAGE FITTINGS, ANSI B16.29 OR TYPE DWV CAST COPPER ALLOY DRAINAGE FITTINGS, ANSI B16.23. FOR PIPING 1" AND SMALLER, WHERE 90 DEGREE ELBOWS ARE REQUIRED, USE LONG RADIUS ELBOWS; ASTM B88 TYPE L COPPER WATER TUBE, HARD DRAWN. FITTINGS SHALL BE WROUGHT COPPER SOLDER FITTINGS AND THREADED ADAPTERS, ANSI B16.22 OR CAST COPPER ALLOY SOLDER JOINT FITTINGS AND THREADED ADAPTERS, ANSI B16.18. SOLDER SHALL BE 95 PERCENT TIN, 5 PERCENT ANTIMONY. 7. CLEANOUTS: FLOOR CLEANOUTS (FCC) SHALL BE JAY R. SMITH FIGURE 4020; CAST IRON BODY AND FRAME, ROUND ADJUSTABLE SECURED NICKEL BRONZE TOP, BRONZE PLUG; PROVIDE CARPET CLAMPING TOP WHERE REQUIRED. WALL CLEANOUTS (WCO) SHALL BE JAY R. SMITH FIGURE 4530-U; ENAMELED CAST IRON CLEANOUT TEE AND COUNTERSUNK TEE WITH STAINLESS STEEL ROUND COVER AND VANDAL PROOF SCREW. 8. THERMOSTATIC MIXING VALVE AT WATER HEATER TO MAINTAIN HOT WATER DISTRIBUTION TEMPERATURE TO 125 DEGREES F: ZURN MODEL ZW1017XL "AQUA GUARD" THERMOSTATIC MIXING VALVE; 0.5 GPM MINIMUM FLOW RATE; 4 PSI PRESSURE LOSS AT 5 GPM FLOW; 3/8 INCH INLET AND OUTLET COMPRESSION FITTINGS; INTEGRAL CHECKS AND SCREEN; CAST BRONZE BODY. MIXING VALVE SHALL COMPLY WITH REQUIREMENTS OF NSF 61 AND SHALL BE ASSE 1017 LISTED. 9. BALANCING/MEASURING VALVES: NIBCO MODEL T 1810 LF LEAD FREE MANUAL BALANCING VALVE; SHALL COMPLY WITH REQUIREMENTS OF NSF 61; BRASS BODY, VENTURI INSERT, BALANCING CONE, DISC, STEM, AND BONNET; EPDM 0-RING; 300 PSI NON -SHOCK COLD WORKING PRESSURE TO 160 DEGREES F; MAXIMUM TEMPERATURE OF 260 DEGREES FAT 150 PSI; FIXED ORIFICE; GLOBE STYLE; DEZINCIFICATION RESISTANT; HIDDEN LOCKING MEMORY STOP; FITTED WITH 2 TEST POINTS FOR DIFFERENTIAL PRESSURE MEASUREMENT; THROTTLING ADJUSTMENT. 10. ELECTRIC WATER HEATERS: SEE MECHANICAL SCHEDULES. WATER HEATER SHALL COMPLY WITH THE WASHINGTON STATE ENERGY CODE. WATER HEATER SHALL BE CONSTRUCTED IN ACCORDANCE WITH ASME CODE. WATER HEATER SHALL INCLUDE ASME TEMPERATURE AND PRESSURE RELIEF VALVE AND DRAIN VALVE. 11. DUCTWORK: MATERIAL, CONSTRUCTION, AND INSTALLATION SHALL MEET REQUIREMENTS OF MOST RECENT EDITIONS OF SMACNA HVAC DUCT CONSTRUCTION STANDARDS, EXCEPT FOR MORE STRINGENT REQUIREMENTS SPECIFIED OR SHOWN ON DRAWINGS. SEE GENERAL NOTES FOR CONSTRUCTION REQUIREMENTS. PROVIDE FLEXIBLE CONNECTION ON ALL DUCTS CONNECTING TO FANS AND ROTATING EQUIPMENT. ALL DUCTS SHALL BE GROUNDED ACROSS FLEXIBLE CONNECTION WITH FLEXIBLE COPPER GROUNDING STRAPS. MAXIMUM LENGTH OF FLEXIBLE RUN -OUT TO DIFFUSERS SHALL BE 6 FEET. FOR LONGER RUN -OUTS, ADD RIGID DUCT. DUCTS SHALL BE CONSTRUCTED OF HOT DIPPED GALVANIZED STEEL UNLESS OTHERWISE NOTED. 12. DELIVERY, STORAGE, AND HANDLING: CONFORM TO REQUIREMENTS OF DIVISION 01. HANDLE, STORE, AND PROTECT EQUIPMENT AND MATERIALS TO PREVENT DAMAGE BEFORE AND DURING INSTALLATION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND AS APPROVED BY ARCHITECT. REPLACE DAMAGED OR DEFECTIVE ITEMS. EQUIPMENT WITH DAMAGED FACTORY APPLIED FINISHES SHALL BE REFINISHED AS REQUIRED TO BRING EQUIPMENT TO A LIKE -NEW CONDITION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 13. FIRE, SMOKE, AND COMBINATION SMOKE/FIRE DAMPERS: PROVIDE FIRE, SMOKE, AND COMBINATION SMOKE/FIRE DAMPERS THROUGHOUT AIR SYSTEMS FOR ALL DUCTS PENETRATING FIRE AND SMOKE RATED WALLS AND PARTITIONS AS REQUIRED BY APPLICABLE CODES, STANDARDS, AND AUTHORITIES. PROVIDE FIRE DAMPERS WITH FRAME AND SLEEVE. PROVIDE ACCESS DOOR FOR EACH DAMPER OF SUFFICIENT SIZE TO REPAIR INTERNAL LINK. DAMPERS SHALL BE AS MANUFACTURED BY GREENHECK, RUSKIN, ARROW, OR APPROVED EQUAL. DAMPER BLADES SHALL BE OUT OF AIR STREAM (UNLESS SIZE IS LARGER THAN AVAILABLE IN CURTAIN TYPE, THEN BLADE TYPE SHALL BE USED, IF ACTUATORS ARE REQUIRED, MECHANICAL CONTRACTOR SHALL INCLUDE THE WIRING COST.). FIRE DAMPERS SHALL BEAR 1-1/2 HOUR MINIMUM UL-RATING FIRE DAMPER LABEL AND BE CONSTRUCTED AND INSTALLED AS REQUIRED BY UL 555. 14. VOLUME DAMPERS: PROVIDE MANUAL ADJUSTABLE VOLUME DAMPERS, WITH EXTENDED MOUNT, INDICATING AND LOCKING QUADRANTS ON EACH TAKE -OFF TO REGISTER, GRILLE, OR DIFFUSER (NOT ALL MAYBE SHOWN ON DRAWINGS). 15. DIFFUSERS, REGISTERS, AND GRILLES: PROVIDE DIFFUSERS, REGISTERS AND GRILLES FOR SUPPLY, RETURN, AND EXHAUST OUTLETS, OF SIZE, TYPE, AND DESIGN SHOWN ON DRAWINGS. DIFFUSER SIZES SHOWN ARE NECK SIZES; REGISTER AND GRILLE SIZE ARE NOMINAL; SEE MECHANICAL SCHEDULES. SPIRAL DUCT MOUNTED LOUVERS SHALL BE FULLY ADJUSTABLE; COORDINATE DISCHARGE ANGLES WITH ARCHITECT. ACCEPTABLE MANUFACTURERS: TITUS, KRUEGER, TUTTLE & BAILEY, PRICE, OR SHOEMAKER. SOUND PRESSURE LEVELS ARE NOT TO EXCEED NC 30. 16. ACOUSTICAL SOUND LINING: INSTALL ACOUSTICAL SOUND LINING IN ALL RETURN AND TRANSFER DUCTWORK; SEE MECHANICAL DETAILS. MATERIALS AND INSTALLATION SHALL MEET THE FOLLOWING STANDARDS, AS APPLICABLE: NFPA-90A, UL723, NFPA-255; SMACNA DUCT LINER APPLICATIONS STANDARD; SMACNA MECHANICAL FASTENERS STANDARD; ADHESIVE AND SEALANT COUNCIL: ADHESIVES STANDARD FOR DUCT LINER - ASTM E-84 FIRE HAZARD CLASSIFICATIONS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED, AND 50 FUEL CONTRIBUTED. INSULATION SHALL HAVE A NOMINAL R-VALUE OF 4.0 AT 1" THICKNESS AND SHALL PASS UL 181 TESTS FOR MOLD GROWTH AND AIR EROSION. INTERNAL AIRFLOW DIMENSIONS ARE SHOWN FOR DUCTS, CONTRACTOR SHALL INCREASE DUCT SIZE FOR LINING. PROVIDE MINIMUM 1" THICK ACOUSTICAL LINING SUITABLE FOR 6,000 FEET PER MINUTE AIR VELOCITY. SEAL ALL JOINTS WITH MANUFACTURER APPROVED MASTIC. USE SHEET METAL NOSING AT ALL RAW EDGES. SEE INSULATION TABLE ON DRAWING FOR SCOPE OF ACOUSTIC DUCT LINING. FACTORY FABRICATED DOUBLE -WALL INTERNALLY INSULATED DUCT WITH PERFORATED PANEL MAYBE USED IN PLACE OF LINING. FIBER GLASS LINING SHALL BE JOHN MANVILLE PERMACOTE LINACOUSTIC OR EQUAL BY CERTAIN -TEED, KNAUF, OR OWENS CORNING. 17. DUCT INSULATION (EXTERNAL): INSULATION SHALL BE CERTAIN -TEED, KNAUF, MANVILLE, OR OWENS CORNING. MATERIALS SHALL MEET REQUIREMENTS OF ADHESIVE AND SEALANT COUNCIL STANDARDS AND SMACNA. MINIMUM DUCTWORK INSULATION THICKNESS SHALL BE AS REQUIRED TO MEET THE WASHINGTON STATE ENERGY CODE. FOR CONCEALED INSULATION, USE FIBROUS GLASS DUCT WRAP, WITH FOIL-KRAFT FLAME RESISTANT VAPOR BARRIER. EXPOSED INSULATION SHALL BE RIGID FIBERGLASS INSULATION WITH ALUMINUM VAPOR BARRIER. DUCTWORK THAT IS RUN OUTDOORS SHALL BE PITCHED FOR DRAINAGE AND INSULATED WITH AT LEAST 2" THICK INSULATION AND ADDITIONALLY COVERED WITH LIGHT COLOR WEATHERPROOF ROOFING MATERIALS. 18. DUCT ACCESSORIES: PROVIDE HANGERS, SUPPORTS, AND ATTACHMENTS FOR SHEET METAL WORK AND EQUIPMENT IN ACCORDANCE WITH SMACNA STANDARDS. 19. FILTERS IN INDUCED AIR DUCTWORK AT FAN POWERED AIR TERMINAL UNITS: FILTER: FARR "30-30" PLEATED MEDIA FILTER OR EQUAL OF AMERICAN AIR FILTER, AIRGUARD, OR PUROLATOR MANUFACTURER; 30 PERCENT EFFICIENCY PER ASHRAE STANDARD 52.1; 1 INCH THICKNESS. 20, WATER PIPING AND VALVES: BLACK STEEL PIPING CONFORMING TO ASTM A531A53M, TYPE E (ELECTRIC_RESISTANCE_WELDED) OR TYPES (SEAMLESS), GRADE A OR GRADE B, STANDARD WEIGHT. CONDENSATE DRAIN PIPING SHALL BE 95/5 SOLDERED ASTM B88 TYPE L COPPER. FITTINGS 2" AND SMALLER SHALL BE ASME B16.3, CLASS 150 THREADED BLACK MALLEABLE IRON OR WELDED, ASME B16.11, CLASS 3000, SCHEDULE 40 STEEL. FITTINGS 2" AND LARGER SHALL BE UL LISTED AND FM APPROVED GROOVED JOINT; ASTM A536 GRADE 65 4512 DUCTILE IRON COUPLINGS. UNIONS (ONLY ON 2" AND SMALLER) SHALL BE BRASS SEATED, ASME B16,39, CLASS 150, ASTM A1971197M THREADED MALLEABLE IRON. PROVIDE FLEX CONNECTORS (DOUBLE SPHERE) AT ALL CONNECTIONS TO ROTATING EQUIPMENT. PROVIDE DIELECTRIC FITTINGS EQUAL TO PPP CLEARFLOW TO CONNECT DISSIMILAR PIPING MATERIALS. VALVES SHALL HAVE NAME OF MANUFACTURER AND GUARANTEED WORKING PRESSURE CASTOR STAMPED ON BODIES. VALVES AND STRAINERS SHALL BE AS MANUFACTURED BY CRANE, MUELLER, APOLLO, WATTS, SARCO, OR MILWAUKEE. BALL VALVES SHALL BE USED ON 2" AND SMALLER WATER PIPING, BUTTERFLY USED ON 2-1/2" AND LARGER WATER PIPING. CALIBRATED COMBINATION BALANCING AND SHUT-OFF VALVES SHALL BE BY ARMSTRONG, BELL AND GOSSETT, FLOWSET, MEPCO, AUTOFLOW, MACON, OR TACO. PROVIDE DIFFERENTIAL PRESSURE METER KIT WITH FLOW CALIBRATION CHARTS. PROVIDE DRAIN VALVES AT LOW POINTS IN PIPING AND VALVED VENTS AT HIGH POINTS. STRAINERS SHALL BE "Y" TYPE (ALTERNATIVELY, NON -REDUCING SUCTION DIFFUSERS MAYBE USED ON PUMP INLETS), FULL SIZE OF ENTERING PIPE SIZE AND HAVE A MAXIMUM CLEAN PRESSURE DROP OF ONE PSID. STRAINERS SHALL INCLUDE BLOW DOWN VALVE. CHECK VALVES SHALL BE SWING TYPE EXCEPT SPRING SILENT TYPE SHALL BE USED FOR PUMP DISCHARGE (ALTERNATIVELY, MULTIPURPOSE PUMP DISCHARGE VALVES CAN BE USED). AUTOMATIC FLOW CONTROL VALVES SHALL BE BY GRISWOLD OR AUTOFLOW WHERE INDICATED ON THE DRAWINGS. VALVES SHALL BE FACTORY SET AND SHALL AUTOMATICALLY LIMIT THE RATE OF FLOW TO REQUIRED ENGINEERED CAPACITY WITHIN S% ACCURACY OVER ITS CONTROL RANGE. PROVIDE DIFFERENTIAL PRESSURE METER KIT. 21. PIPE INSULATION: WATER PIPING INSULATION SHALL BE FIBROUS GLASS INSULATION WITH FACTORY -APPLIED FIRE RETARDANT VAPOR BARRIER JACKET WITH K FACTOR OF AT LEAST 0.23 AT 75 DEG. F MEAN TEMPERATURE BY OWENS CORNING, CERTAIN -TEED, MANVILLE, OR KNAUF. ASTM E-84 FIRE HAZARD RATINGS SHALL BE 25 FLAME SPREAD, 50 SMOKE DEVELOPED AND 50 FUEL CONTRIBUTED. 22. PIPE HANGERS AND SUPPORTS: PROVIDE PIPE STANDS, SUPPORTS, HANGERS, AND OTHER SUPPORTING APPLIANCES AS NECESSARY TO SUPPORT WORK REQUIRED BY CONTRACT DOCUMENTS. SPACING OF HANGERS SHALL BE INSTRUCTED IN ACCORDANCE WITH APPLICABLE BUILDING AND MECHANICAL CODES. SIZE OF HANGERS SHALL INCLUDE THE PIPE INSULATION WITH SHIELD. 23. EXPANSION TANKS: ACCEPTABLE MANUFACTURERS ARE AMTROL, TACO, BELL AND GOSSETT, MEPCO, WOOD, ARMSTRONG, OR WHEATLEY. BLADDER -TYPE EXPANSION TANKS PRE -PRESSURIZED WITH AIR TO THE OPERATING PRESSURE INDICATED, AND PERMANENTLY SEALED FROM THE SYSTEM BY THE BLADDER. ASME CONSTRUCTION AND RATED FOR 125 PSIG. PART 3 - EXECUTION INSTALLATION OF EQUIPMENT: INSTALL ALL ITEMS SPECIFIED UNDER PART 2 - PRODUCTS, ACCORDING TO THE MANUFACTURER'S REQUIREMENTS, SHOP DRAWINGS, AND DETAILS AS SHOWN ON THE DRAWINGS AND AS SPECIFIED. INSTALL ALL WORK SO THAT PARTS REQUIRING INSPECTION, REPLACEMENT, MAINTENANCE AND REPAIR SHALL BE READILY ACCESSIBLE. MINOR DEVIATIONS FROM THE DRAWINGS MAY BE MADE TO ACCOMPLISH THIS, BUT ANY SUBSTANTIAL CHANGE SHALL NOT BE MADE WITHOUT PRIOR WRITTEN OWNER APPROVAL. 2. FILTERS: PROVIDE TEMPORARY FILTERS FOR EQUIPMENT AND IN DUCTWORK AND PLENUMS FOR ASSOCIATED FANS THAT ARE OPERATED DURING CONSTRUCTION, AND AFTER CONSTRUCTION DIRT HAS BEEN REMOVED FROM THE BUILDING, PROVIDE NEW FILTERS. 3. IDENTIFICATION: ALL EQUIPMENT, PIPING, VALVES, AND DUCTWORK PROVIDED UNDER THIS SECTION OF THE SPECIFICATIONS SHALL BE MARKED FOR EASE OF IDENTIFICATION PER OWNER'S OR INDUSTRY STANDARDS. 4. CLEANING: DUCTS SHALL BE THOROUGHLY CLEANED SO THAT NO DIRT OR DUST SHALL BE DISCHARGED FROM DIFFUSERS, REGISTERS, OR GRILLES, WHEN SYSTEM IS OPERATED. AFTER ALL WATER AND CONDENSATE PIPING SYSTEMS HAVE BEEN PRESSURE TESTED AND APPROVED FOR TIGHTNESS, CLEAN AND FLUSH PIPING. AFTER COMPLETION OF PROJECT, CLEAN EXTERIOR SURFACES OF ALL EQUIPMENT INCLUDED IN THIS SECTION, INCLUDING REMOVAL OF CONCRETE RESIDUE. AFTER COMPLETION OF PROJECT, REMOVE ALL CONSTRUCTION DEBRIS, TEMPORARY FACILITIES AND EQUIPMENT FROM WORK AREA, CLEAN WORK AREA TO PERMIT OCCUPATION. 5. TESTING AND INSPECTION: PROVIDE QUALIFIED PERSONNEL, EQUIPMENT, APPARATUS, AND SERVICES FOR TESTING AND INSPECTION OF MECHANICAL SYSTEMS. DO NOT COVER OR CONCEAL WORK BEFORE TESTING AND INSPECTION AND OBTAINING APPROVAL. MEDIUM PRESSURE DUCTWORK SHALL BE LEAKAGE TESTED WHERE CALLED FOR ON THE DUCT CONSTRUCTION AND LEAKAGE CLASS SCHEDULE. ALLWATER PIPING SHALL BE HYDROSTATICALLY TESTED AT 125% OF DESIGN PRESSURE (125 PSIG MINIMUM). LEAKS, DAMAGE, AND DEFECTS DISCOVERED OR RESULTING FROM TESTING SHALL BE REPAIRED OR REPLACED TO LIKE -NEW CONDITION WITH ACCEPTABLE MATERIALS. TESTS SHALL BE CONTINUED UNTIL SYSTEMS OPERATE WITHOUT LEAKS OR REPAIRS. REPORT ON INDUSTRY STANDARD REPORTING FORMS, SUBMITTED FOR APPROVAL IN ADVANCE. SUBMIT SIX COPIES OF TESTING REPORTS FOR APPROVAL. CONTRACTOR SHALL FURNISH ALL TEST MEDIUMS AND DISPOSE OF ALL TEST MEDIUMS AT AN APPROVED OFFSITE LOCATION AFTER TESTING IS COMPLETE. 6. STARTUP AND BALANCING: PROVIDE NEBB OR AABC CERTIFIED PERSONNEL, EQUIPMENT, APPARATUS, AND SERVICES FOR START-UP AND BALANCING OF MECHANICAL SYSTEMS TO PERFORMANCE DATA SHOWN IN SCHEDULES AND ON DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY CODES, STANDARDS, REGULATIONS, AND AUTHORITIES HAVING JURISDICTION INCLUDING CITY INSPECTORS. AIR AND WATER FLOWS SHALL BE BALANCED TO +I-10% OF DESIGN, LEAKS, DAMAGE, AND DEFECTS DISCOVERED OR RESULTING FROM START-UP AND BALANCING SHALL BE REPAIRED OR REPLACED TO LIKE -NEW CONDITION WITH ACCEPTABLE MATERIALS. TESTS SHALL BE CONTINUED UNTIL SYSTEM OPERATES WITHOUT ADJUSTMENTS OR REPAIRS. REPORT DATA ON INDUSTRY STANDARD NEBB OR AABC REPORTING FORMS. AIR TERMINAL UNIT DATA SHALL INCLUDE ALL PRIMARY AIRFLOWS (MAXIMUM, MINIMUM AND HEATING). FAN POWERED BOXES SHALL INCLUDE ALL PRIMARY AIRFLOWS, FAN AIRFLOW, AND MOTOR DATA, SUBMIT SIX COPIES OF START-UP AND BALANCING REPORTS TO ARCHITECT FOR APPROVAL. PRIOR TO THE START OF DEMOLITION, THE TESTING AND BALANCING CONTRACTOR SHALL TAKE CFM AND STATIC PRESSURE READINGS AT AREAS DESIGNATED ON THE CONTRACT DRAWINGS. READINGS SHALL BE SUBMITTED PRIOR TOSTART OF NEW WORK. PART 4 - PROJECT CLOSEOUT 1. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ITEMS ASSOCIATED WITH PROJECT CLOSEOUT. ALLOW SUFFICIENT TIME IN THE CONSTRUCTION SCHEDULE TO ENSURE THAT THE INSTALLATION IS SUBSTANTIALLY COMPLETE AND ALL REQUIRED TESTING AND ACCURATELY COMPLETED DOCUMENTATION IS DELIVERED TO THE ENGINEER AT LEAST TWO WEEKS PRIOR TO ENGINEER'S SUBSTANTIAL COMPLETION SITE VISIT. FAILURE TO ADEQUATELY PLAN OR SUBMISSION OF INCOMPLETE/INCORRECT DOCUMENTATION WILL RESULT IN BACK CHARGES OF ALL COSTS ASSOCIATED WITH ADDED WORK PERFORMED BY ENGINEERS. 2. INSPECTION: WHEN REQUESTING FINAL INSPECTION, SUBMIT WRITTEN CERTIFICATION THAT WORK HAS BEEN FULLY COMPLETED IN STRICT ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. SUBMIT WRITTEN CERTIFICATION OF INSPECTION FROM GOVERNING BUILDING AUTHORITY STATING THAT WORK HAS BEEN INSPECTED, ACCEPTED, AND APPROVED AS COMPLYING WITH EXISTING GOVERNING ORDINANCES AND CODES. 3. PROVIDE BACKUP DOCUMENTATION TO VERIFY THAT ALL FIRE DAMPERS AND SMOKE/FIRE DAMPERS HAVE BEEN INSTALLED PER MANUFACTURER'S REQUIREMENTS AND THAT ALL FUNCTION PROPERLY. 4. PROVIDE BACKUP DOCUMENTATION TO VERIFY THAT ALL SEQUENCES OF OPERATIONS AND CONTROLS HAVE BEEN INCORPORATED AND ALL SYSTEMS AND EQUIPMENT ARE WORKING PER THE SPECIFIED SEQUENCES OF OPERATIONS. 5. PROVIDE BACKUP DOCUMENTATION THAT ALL DUCT AND PIPING LEAKAGE AND PRESSURE TESTS HAVE BEEN CONDUCTED AND THAT ALL SYSTEMS HAVE PASSED. PROVIDE START-UP AND BALANCING REPORTS FOR ALL AIR AND WATER SYSTEMS, AIR BALANCING REPORT SHALL VERIFY THE DESIGN OUTDOOR AIR IS BEING SUPPLIED TO THE BUILDING. 6. SUBSTANTIAL COMPLETION SITE VISIT BY THE ENGINEER SHALL BE CONDUCTED AFTER RECEIPT AND REVIEW OF THE CONTRACTOR'S CERTIFICATE OF COMPLETION AND ALL CODE MANDATED TEST REPORTS AND SUBMISSIONS LISTED ABOVE. SUBSTANTIAL COMPLETION SITE VISITS SHALL NOT BE REQUESTED UNTIL THE PROJECT IS SUBSTANTIALLY COMPLETE. 7. PREMATURE REQUESTS THAT REQUIRE ADDITIONAL/FOLLOW UP SITE VISITS BY THE ENGINEER OF DEFICIENT ITEMS (AREAS INCOMPLETE, SYSTEMS NOT OPERATIONAL, ETC.) WILL RESULT IN BACK CHARGES OF THE COSTS ASSOCIATED WITH ANY ADDED VISITS. SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 BURGESS DESIGN INTERIORS - ARCHITECTURE Al reproduction ! YrbMatual praparbr rights moved c 2017 Wood Har i bn er 929 io8th Ave NE, Suite woo Bellevue, WA 9800y 425.628.6000 woodharbingermm Professional *sal No. issue Description Dote REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City Electronk Stamp Lacatlon PG l q- �UoO CCQ C v, uAi,; ; AF'R >O,VLO OCT 23 2019 City of TUkwla 8UIL DNG CIVsti -N CITY C4 TUN.WILA OCT 18 2019 PERMIT CENTER Drown by MK Project Manager: RM Project No: 19.0168.00 MECHANICAL SPECIFICATIONS Original drabs M 24' x 36'. Soak snlp.s Goon** If named M.0.3 WH-1 3/4HW DN 11111111111/11111 ' CW D Imirtrio3/4 4" W ) 1-1/4" CW ra 3/4" CW DN 2" W - 2" IN WALL 2" V -11 2-1/2" CW DN 1-1/4" CW 111 -I- lk 1111101111; ED6-1--D ENLARGED DEMOLITION PLUMBING PLAN on 0 4' 8' 12' (E)WH GENERAL NOTES: 1. REMOVE DIFFUSERS AND GRILLES AS SHOWN. RETAIN DUCTWORK SERVING DIFFUSERS AND GRILLES FOR NEW EQUIPMENT. SEE SHEET M.2.1. 2. MODIFY FIRE SPRINKLER PIPING TO ACCOMMODATE NEW CEILING 'TYPE AND LAYOUT. SEE SHEET M.2.1. SHEET NOTES: [1>,- REMOVE DIFFUSER. RETAIN CDF-1 FOR NEW DIFFUSER. SEE SHEET M.2.1. 11::>- REMOVE EXISTING PLUMBING FIXTURE. RETAIN ASSOCIATED PIPING FOR RECONNECTION VVITH NEW EQUIPMENT. mom. 11111111111=11 'CDAR 111111 • 111=111 II I MID IIrn (E RG (E) RTU-5--/f 14X14 UP TO (E) EF-6 TG (E) CDF-1.< (E) TG (E) CD /1111 ilt# II (E) EG All AM IOW III Aiiiiin sem lJ 111/1111W11111111f73111 viz EG Mir Fr (E) RO ED ENLARGED DEMOLITION HVAC PLAN 4110 n-1 1/4- = 0 4' 8' 12' BUILD: DiVOION SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 BURGESS DESIGN INTERIORS + ARCHITECTURE reproduction .dectuol properly rights reamed c 2017 Wood Harbinger 929 i.o8th Ave NE, Suite l000 Bellevue, WA 9800y 425.628.6000 woodharbingencom Professional seal No. Issue Description Dote REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City Electronic Stamp Location KR- MO f - 0 CCD: APP,Ov OCT 28 2019 Drawn by: MK Project Manager: RM Project No: 19.0168.00 City of Tukwila ENLARGED DEMOLITION MECHANICAL RES TROOM rtEc-.EivEn PLAN CITY OF IL W:LA OCT 18 2019 Original droving 6 24. x IV. S. entSlos amordogly r.00d PERMIT CENTER M. 1 . 1 1/2" CWDN /2" CWDN ENLARGED PLUMBING PLAN LJfl 0 8' 12' 6 340 ® 14X14 UP TO (E) 22X10 340 16 ® 420 UP TO (E) CDF-1 22X10 340 (E) HE- 150 8X6 ENLARGED HVAC PLAN 0 4' 8' 12' GENERAL NOTES: 1. INSTALL DIFFUSERS AND GRILLES AS SHOWN. CONNECT DIFFUSERS AND GRILLES TO EXISTING MAIN DUCTWORK. 2. MODIFY FIRE SPRINKLER PIPING TO ACCOMMODATE NEW CEILING TYPE AND LAYOUT. SHEET NOTES: PROVIDE DUCTWORK AS NEEDED TO CONNECT DIFFUSER/GRILLE TO EXISTING MAIN DUCTWORK. [2:>. PROVIDE DUCTWORKAS NEEDED TO CONNECT TRANSFER GRILLES. SEE DETAIL ON SHEET M.5.1. CONNECT NEW DIFFUSER TO EXISTING UNIT (CDF-1). [1:>> PROVIDE ACCESS PANEL FOR RELOCATED ELECTRICAL EQUIPMENT. 1:2>.• SEE DETAIL 4 ON SHEET M.5.1 FOR LAVATORY CONNECTION DIAGRAM. SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 BURGESS DESIGN INTERIORS ARCHITECTURE PA reproduction & 0tokt, crawly rights rem. o 2017 Wood Harbinger 3.98th Ave NE, Suite woo Bellevue, WA 98oey 425.628.6000 woodharbingencom Professional seal No. Issue Description Date REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City Electronic Stomp Location PG161.-0160 , , . ...._ OCT 28 2019 City of Tukwila ENLARGED MECHANICAL BUILD; <3 DiV-Z,I,-)N Drowl, by. MK Proied Mono9ea RM ProOct No: 19.0168.00 "MEWED CITY OF "f1:WILA OCT 18 2019 PERMIT CENTER RESTROOM PLAN Orighol drawing h 24" x 38'. Scals main am.* nduced M.2.1 22 GAUGE GALVANIZED STEEL PERFORATED PLATE WITH 63 PERCENT FREE AREA ACROSS PLENUM. TOP OF PLATE AT CENTERLINE OF INLET CONNECTION SIZE SCREW PLENUM TO DIFFUSER NECK �,w /MIN PLENUM INLET, SAME SIZE AS DIFFUSER NECK SIZE (IE 8x8 = 8"0) CLAMP (TYP) CEILING DIFFUSER /- VOLUME DAMPER SUPPLY DUCT VOLUME DAMPER HARD ROUND DUCT AS REQUIRED TO LIMIT FLEX DUCT LENGTH TO 5'-0" MAX FLEX DUCT, SAME SIZE AS NOTE: PLENUM INLET 1. SET DIFFUSER FOR FOUR-WAY HORIZONTAL FLOW UNLESS AIR FLOW INDICATED ON DRAWINGS HARD LID CEILING DUCT LINED BOOT -� 7 2D OR 3 FT MIN 11 1 1 1 1) J l CEILING - J L I I I J l I L PARTITION NOTES: 1. DUCT FULL SIZE OF TRANSFER GRILLE NECK UNLESS OTHERWISE SHOWN ON PLANS. 2. D=NECK OF TRANSFER GRILLE CEILING DIFFUSER/GRILLE WITH INLET PLENUM DETAIL TRANSFER BOOT WITH GRILLES DETAIL SCALE: NONE M.0.1, M.2.1 0 1-1/2"CW FROM SOURCE (E) DCVA THERMOSTATIC MIXING VALVE 10 GPM @ 60 PSI PRESS DROP, SET 125°F 1"CW _\ I ET-1 I 1"CW VACUUM BREAKER ASSEMBLY 3/4"D DISCHARGE DRAIN PIPING INDIRECTLY +/ - 3" ABOVE MOP SINK 0 TEMP / PRESSURE RELIEF VALVE, 80 PSI 1"HW (125°F) TO PLUMBING FIXTURES PRESSURE GAUGE 3/4"HW (140°F) TO JANITOR'S MOP SINK HEAT TRAP, 27" DROP MIN. 1"HW (140°F) THERMOMETER -"'A------- T _ DIELECTRIC UNION (TYP) DRAIN FULL SIZE TO MOP SINK 1-I WH-1 /' <-1nnn.,��.nn �-ANCHOR TO STRUCTURE HOSE END DRAIN VALVE f FOAM INSULATION PAD DRAIN PAN WATER HEATER SUPPORT, UTILIZE FULL OPERATING WEIGHT FOR STRUCTURAL AND SEISMIC CALCULATIONS FLOOR MOP SINK ELEVATED ELECTRIC WATER HEATER PIPING DIAGRAM 0 SCALE: NONE M.0.1, M.2.1 SCALE: NONE M.0.1, M.2.1 HW SUPPLY UP WHERE INDICATED ON PLANS 125°F HW SUPPLY (SIZE INDICATED ON PLANS) 1/2" CW SUPPLY PLUMBING WALL MAKE CONNECTION WITHIN 24" OF STOP VALVE STOP VALVE Ti STOP VALVE LAVATORY PIPING DIAGRAM TRANSFER GRILLE FAUCET LAVATORY 105°F HW SUPPLY SCALE: NONE M.2.1 0 MIXING VALVE SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 UNIBAIL-ROUAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 BURGESS DESIGN INTERIORS ARCH I T E C T U R E 40 reproduction & InOM otuai prop.* rights rearmed c 2017 Wood Harbinger gzq 208th Ave NE, Suite i000 Bellevue, wA 98o, 425.628.6000 woodha rbinger. cam Professional sect No. Issue Description Date REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City Electronic Stomp Location PG141-01ba AP §�„ • ;- ACT. 2 8 2019 City of Tufr• va fEC.E►VEn CITY OF -I L:..r 4LA OCT 18 2019 PERMIT CENTER MK Project Manager: RM Project No: 19.0168.00 MECHANICAL DETAILS & DIAGRAMS NOTES alprd drains g 24' x 3g'. Sod, align accord* if reduced M.5.1