Loading...
HomeMy WebLinkAboutPermit PG19-0166 - AMAZON - PLUMBING, VENTS AND WATER SUPPLYAMAZON 535 SOUTHCENTER MALL PGI 9-0166 Parcel No: Address: ��^�«x ^�� ��n�^xv~U v~�~� v�o Tukwila of Department of Community Development 6300 SnwthcenterBoulevard, Suite #IOV Tukwila, Washington 9g1OO Phone: 206-431'3670 Inspection Request Line: 2U6-43g'9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 9202470010 Permit Number; PG19-0166 Project Name: AMAZON Issue Date: 5/21/2020 Permit Expires On: 11/17/2020 Owner; Name; Contact Person: Name: Contractor: Name: License No: Lender Name: VVE6TFELDPROPERTY TAX DEPT POBOX 130940'Q\RLS8AD,WA, 92013 ANDREA3PEED lQ09SEVENTH AVE 5UITE7OO, PLUMBING EXPRESS INC POBOX ZZZ6,SUk4NEP,WA, 98390 PLUK8BO98600 "I Phone (253)826`4621 Expiration Date: 9/20/2020 DESCRIPTION OF WORK: PLUMBING WASR, VENTS AND POTABLE WATER SUPPLY FOR TENANT IMPROVEMENT Valuation of Work: $15,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $336,87 Current Codes adopted bythe City nfTukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVAC296-4613: y Code: / � ��: c�/"�/�°* |heorbycertify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting ufthis permit does not presume *xgive authority toviolate orcancel the provisions ofany other state n/local laws regulating construction orthe performance -of work, |amauthorized tosign and obtain this development permit and agree tothe conditions attached tothis permit. Signature: Print Name: This permit shall become null and void if the work bnot commenced within I8Ddays for the date ofissuance, cxif the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: l: °*~PLUK4B|NG/GASPIPING PERMIT CONDITIONS` 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall beinstalled incompliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: Noportion nfany plumbing system or gas piping shall beconcealed until inspected and approved. G: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall beconducted inthe presence ofthe Plumbing Inspector. |tshall bethe duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work isready for inspection. 7: wowater, ooi|'orwastepipeshaUbeinma||ed orpermitted out,idocf a building orinanexterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall beinsulated tominimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall beprotected bysteel nail plates not less than 18gauge. 8: Piping through concrete ormasonry walls shall not besubject toany load from building construction. No plumbing piping shall bedirectly embedded in concrete ormasonry. 10t All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected {naccordance with the requirements nfthe building code. 11: Piping inthe ground shall belaid onofirm bed for its entire length. Trenches shall bebacWiUedinthin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderMU,frozen earth, orconstruction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance ofthe jurisdiction. lJ: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures In all residential, hotel, motel, schocl, industrial, commercial use or other occupancies that use significant quantities ofwater shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section uOZofWashington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (IV6)u3O935V 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Plumbing/Gas Permit No. 'V l `� '` O f t0b Project No. Date Application Accepted: / (k.)--4 9 Date Application Expires: )1--)--)-'"2 t (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 634' King Co Assessor's Tax No.: Site Address: 2800 Southcenter Mall Seattle, WA 98188 Suite Number: 535 Floor: L1 Tenant Name: Amazon PROPERTY OWNER Name: Unibail-Rodamco-Westfield Address: 2049 Century Park East 41st Floor City: Los Angeles State: CA Zip: 90067 CONTACT PERSON — person receiving all project communication Name: Andrea Speed Address: 1809 Seventh Ave. Suite 700 City: Seattle State: WA Zip: 98101 Phone: (206) 519-5141 Fax: Email: Andrea.Speed@graphitedesigngroup.com New Tenant: Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ L' ° S� Scope of Work (please provide detailed information): Interior tenant improvement of a shopping mall space for a retail use. Work includes demo of previous tenant work, storefront modifications, interior partitions, interior doors, suspended ceilings, lighting, finishes, furniture, casework and associated mechanical, electrical, plumbing, and security systems. Building Use (per Int'l Building Code): M -Mercantile Occupancy (per Int'l Building Code): M - Mercantile Utility Purveyor: Water: Submetered from Landlord Sewer Submetered from Landlord H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Oak Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain __ Shower, single head trap Sinks -- Rain water system — per drain (inside building) -- Grease interceptor for commercial kitchen (>750 gallon capacity) -- Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) -- Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 2 lavatory 2 Urinal -- Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment 1 Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial -- Wash fountain -- Water closet 2 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors -- Repair or alteration of drainage or vent piping 1 Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 nun) diameter Gas piping outlets -- Fixture Type Qty Dental unit, cuspidor __ Floor drain 2 Receptor, indirect waste -- Building sewer and each trailer park sewer -- Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity -- Medical gas piping system serving 1-5 inlets/outlets for a specific gas -- Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER, OR AUTHORIZED AGENT: Signature: "fT�_icr_J Print Name: Andrea Speed Date: Day Telephone: (206) 519-5141 Mailing Address: 1809 Seventh Ave Suite 700 Seattle WA 98101 City State Zip H:Wpptications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8.9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK .$273.62 PG19-0166 Address: 535 SOUTHCENTER MALL Apn: 9202470010 .$273.62 Credit Card Fee $7.97 Credit Card Fee R000.369.908.00.00 0.00 $7.97 PLUMBING $253.00 PERMIT FEE R000.322.100.00.00 0.00 $218.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 TECHNOLOGY FEE $12.65 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R20806 R000.322.900.04.00 0.00 $12.65 $273.62 Date Paid: Thursday, May 21, 2020 Paid By: JOHN KILDARE Pay Method: CREDIT CARD 05899G Printed: Thursday, May 21, 2020 9:36 AM 1 of 1 tl / .J SYSTEM CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 05/21/2020 09:35:29 AM VISA CARD NUMBER: TRAN AMOUNT: APPROVAL CD: RECORD #: CLERK ID: X CREDIT CARD SALE **********9131 K $273.62 05899G 000 Laurie {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY " PAID 4.-,.1'c' , PermitTRAK ..'-"; i!Irk:':'.!j',.:iir1:4',-. ' , ' '' ' , ,$3;751..02' D19.0339 Acidri:,,35 .,F6tj:+iieiki.iii,,MALL ,,r;eio,bi4i661„ ,,,,, DEVELOPMENT., PLAN CHECK FEE R000.345.830.00.00 0.00 $3,624.16 M19-0179 Address* 535ouirf'-ieiivi-EFt'i/IAL1: Apn: 9202470010 $63.61 MECHANICAL $63.61 PLAN CHECK FEE R000.322.102.00.00 0.00 $63.61 PG19-0166 Address: 535 SOUTHCENTER MALL Apn: 9202470010 $63.25 PLUMBING $63.25 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R18882 R000.322.103.00.00 0.00 $63.25 $3,751.02 Date Paid: Tuesday, October 22, 2019 Paid By: PERMIT ADVISORS INC Pay Method: CHECK 10845 Printed: Tuesday, October 22, 2019 8:47 AM 1 of 1 CRWY5TEMS INSPECTION RECORD Retain a copy with permit IN PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: —':.� p.m. -• Requester:.Z0(0-45— �� / Phone No: Approved per applicable codes. CO MENTS: Corrections required prior to approval. 'inspector: Date: -2© REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projecctt: Type ol` Inspection: Address: -Date Called: 635 5 . 77K1W Special Instructions: Date Wanted: Z a.m. p.m. Requester: Phone No: Approved per applicable codes. © Corrections required prior to approval. CO MENT ,.. 'Inspector: =Date; (e� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development 3/5/2020 ANDREA SPEED 1809 SEVENTH AVE - SUITE 700 SEATTLE, WA 98101 RE: Permit Application No. PG19-0166 AMAZON 535 SOUTHCENTER MALL Dear ANDREA SPEED, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 10/22/2019, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 4/22/2020. If you still plan to pursue your project, you are hereby advised to do one of the following: I) If the plan review is complete for the project and your application is approved, you nay pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: PGI9-0166 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY o PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0166 DATE: 10/22/19 PROJECT NAME: AMAZON SITE ADDRESS: 535 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division t ANC 10101 o- VIA PRrWorkts Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable 111 (no approval/review required) REVIEWER'S INITIALS: Planning Division Permit Coordinator DATE: 10/24/19 1-1 U Structural Review Required APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DATE: DUE DATE: 11/21/19 LI LJ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PLUMBING EXPRESS INC Page 1 of 3 L&I regional offices are closed to public visits until further notice. Offices can still help you by phone from 8 a.m. to 5 p.m. weekdays (except state holidays). Use the phone number for your closest regional office (htlps://lni.wamov/anency/contact/#office-locations), or you can call the Office of Information and Assistance at 360-902-5800. Orpero7t n1 C; Labor & Industries ihttps: //eirti, wa OV PLUMBING EXPRESS INC Owner or tradesperson Principals KILDARE, JOHN THOMAS, PRESIDENT KILDARE, KRISTI KYLE, VICE PRESIDENT Doing business as PLUMBING EXPRESS INC WA UBI No. 602 226 682 PO BOX 2226 SUMNER, WA 98390 253-826-4621 PIERCE County Business type Corporation Governing persons JOHN THOMAS KILDARE KRISTI KYLE KILDARE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties PLUMBING License no. PLUMBEI98600 Effective — expiration 09/20/2002— 09/20/2020 Bond No bond accounts during the previous 6 year period. Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS2154313254 Received by L&I Effective date 11/13/2019 01/01/2020 Expiration date 01/01/2021 httnq•//gernre lni wa any/verify/Detail asnx7T TRI=607.7.766R7&J,IC=PIJ INATIF:198600&SAW= 5/21/2020 ABBREVIATIONS PROJECT DATA PROJECT TEAM OWNER amazon 17 ACC ACCESSIBLE FR FRAME, FIRE RATED ACP ACOUSTICAL CEILING PANEL FRMG FRAMING PNTD PAINTED AtST ACOUSTICAL FRPF FIREPROOF, FIREPROOFING PBD PARTICLEBOARD AD AREA DRAIN FRT FIRE RETARDANT TREATED PRCST PRECAST ADDM ADDENDUM FS FLOOR SINK PD PLANTER DRAIN ADJ ADJUSTABLE FT FOOT, FEET PERP PERPENDICULAR PLAM PLASTIC LAMINATE AFC ABOVE FINISH CEILING FTG FOOTING PLAS PLASTER AFF ABOVE FINISHED FLOOR FUT FUTURE AHU AIR HANDLING UNIT FVC FIRE HOSE VALVE CABINET PLYWD PLYWOOD PNL PANEL ALT ALTERNATE FWC FABRIC WALL COVERING PL PROPERTY LINE ALUM ALUMINUM FWP FABRIC WALL PANEL(S) AMP AMPERAGE PR PAIR ANOD ANODIZED GA GAUGE PRPARKING APPROX APPROXIMATE GALV GALVANIZED PROPOP PROPERTY ARCH ARCHITECT, ARCHITECTURAL GB GRAB BAR PT PAINT, POINT AUTO AUTOMATIC GC GENERAL CONTRACTOR PTD PAPER TOWEL DISPENSER AV AUDIO VISUAL GEN GENERAL, GENERATOR PTN PARTITION AWG AMERICAN WIRE GAUGE GFRC GLASS -FIBER REINFORCED QUAL QUALITY AWP ACOUSTICAL WALL PANEL(S) CONCRETE GFRC GLASS FIBER REINFORCED QTY QUANTITY BCT BABY CHANGING TABLE GYPSUM R RADIUS, RISER BD BOARD GFRC GLASS FIBER REINFORCED RCP REFLECTED CEILING PLAN BLDG BUILDING PLASTIC RD ROOF DRAIN, ROAD BLKG BLOCKING GL GLASS@ RECP RECEPTACLE BM BEAM GYP GYPSUM BO BOTTOM OF GYP BD GYPSUM BOARD REF REFER TO, REFERENCE BOT BOTTOM REINF REINFORCED, REINFORCING BRG BEARING H HIGH REQD REQUIRED BRZ BRONZE HB HOSE BIBB BSMT BASEMENT HC HOLLOW CORE REV REVISED, REVISION RFG ROOFING BUR BUILT UP ROOFING HD HAND DRYER RM ROOM HDBD HARDBOARD RO ROUGH OPENINGc. CAB CABINET HDW HARDWARE RT RIGHT CB CATCH BASIN HDWD HARDWOOD CEMENT, CEMENTITIOUS HM HOLLOW METAL S SOUTH CER CERAMIC HO HOLD OPEN SAM SELF ADHERING MEMBRANE CG CORNER GUARD HORIZ HORIZONTAL SC SOLID CORE CH COAT HOOK HPL HIGH PRESSURE LAMINATE SCD SEAT COVER DISPENSER CI CAST IRON HR HOUR SCHED SCHEDULE U CONTROL JOINT HT HEIGHT SCW SOLID CORE WOOD CIP CAST -IN -PLACE HVAC HEATING, VENTILATING AND SD STORM DRAIN CL CENTERLINE AIR-CONDITIONING SD SOAP DISPENSER CLG CEILING HWRE HARDWARE SECT SECTION CLO CLOSET HW HOT WATER SGL SINGLE CLR CLEAR SHT SHEET CMU CONCRETE MASONRY UNIT ID INSIDE DIAMETER SHTHG SHEATHING CO CLEAN OUT, CASED OPENING IN INCH SIM SIMILAR COL COLUMN INCL INCLUDE, INCLUDING SNR SANITARY NAPKIN RECEPTACLE COMM COMMUNICATION INFO INFORMATION SPEC SPECIFICATION CONC CONCRETE INSUL INSULATE, INSULATING, SPKLR SPRINKLER CONNECTION, CONNECT INSULATION SPKR SPEAKER CONSTR CONSTRUCTION INT INTERIOR CONE CONTINUOUS, CONTINUE IWD INDIRECT WASTE DRAIN SQ SQUARE SS SERVICE SINKSANITARY SEWER CORR CORRIDOR , SST STAINLESS STEEL CPT CARPET JAN JANITOR CSWK CASEWORK JT JOINT STC SOUND TRANSMISSION CLASS STD STANDARD CTR CENTER STL STEEL CU CUBIC KIT KITCHEN STOR STORAGE STOR STRUCTURAL D DEEP, DEPTH L LONG25 CUSP SUSPENDED DOUBLE LL LANDLORD DEMO DEMOLISH, DEMOLITION LAM LAMINATE, LAMINATED T TREAD DEPT DEPARTMENT LAU LAUNDRY T&G TONGUE AND GROOVE DET DETAIL LAV LAVATORY TEL TELEPHONE DF DRINKING FOUNTAIN LT LIGHT DIA DIAMETER LTG LIGHTING TEMP TEMPERATURE, TEMPORARY TER TERRAZZO DIAL DIAGONAL, DIAGRAM THK THICK, THICKNESS DIM DIMENSION MAS MASONRY TMPD TEMPERED DIV DIVIDE, DIVISION MAIL MATERIAL TO TOP OF DN DOWN MAX MAXIMUM TPD TOILET PAPER DISPENSER DR DOOR, DRESSING ROOM MCG METAL CORNER GUARD TSTAT THERMOSTAT DS DOWNSPOUT MECH MECHANICAL TV TELEVISION DWG DRAWING MED MEDIUM TYP TYPICAL DWR DRAWER MEMB MEMBRANE MEZZ MEZZANINE E EAST MGT MANAGEMENT UGND UNDERGROUND UNFIN UNFINISHED EIFS EXTERIOR INSULATION AND MFR MANUFACTURER UON UNLESS OTHERWISE NOTED FINISH SYSTEM MH MANHOLE UR URINAL EJ EXPANSION JOINT MH MOP/BROOM HOLDER EL ELEVATION MIN MINIMUM, MINUTE VCT VINYL COMPOSITE TILE ELEC ELECTRIC, ELECTRICAL MISC MISCELLANEOUS VERT VERTICAL ELEV ELEVATOR MIR MIRROR VEST VESTIBULE ENCL ENCLOSE, ENCLOSURE MO MASONRY OPENING VIF VERIFY IN FIELD ENGR ENGINEER MS MOP SINK EP ELECTRICAL PANEL MTD MOUNTED VNR VENEER EQ EQUAL MTL METAL VR VAPOR RETARDER EQUIP EQUIPMENT MVBL MOVABLE VWC VINYL WALLCOVERING EXISTING W WEST, WIDE EXH EXHAUST N NORTH W/ WITH EXP EXPANSION, EXPOSED NIC NOT IN CONTRACT W/O WITHOUT EXTR EXTERIOR NO NUMBER WC WATER CLOSET, WALLCOVERING N— FA FIRE ALARM NTOS NOT 0 SCALE WD WOOD WH WALL HYDRANT FCIC FURNISHED BY CONTRACTOR/ INSTALLED BY CONTRACTOR OC ON CENTER WP WEATHERPROOF, WATERPROOF, fC10 FURNISHED BY CONTRACTOR) OCC OCCUPANT, OCCUPANTS, WATERPROOFING, WORK POINT WR WATER RESISTANT INSTALLED BY OWNER OCCUPANCY WR WASTE RECEPTACLE W/FLIP TOP LID FD FLOOR DRAIN OH OVERHEAD WT WEIGHT FDC FIRE DEPARTMENT CONNECTION OD OUTSIDE DIAMETER WWF WELDED WIRE FABRIC FDTN FOUNDATION OPNG OPENING FE FIRE EXTINGUISHER OPP OPPOSITE XFMR TRANSFORMER FEC FIRE EXTINGUISHER CABINET ORD OVERFLOW ROOF DRAIN FH FIRE HYDRANT OTS OPEN TO STRUCTURE ABOVE FHC FIRE HOSE CABINET FIG FIGURE FIN FINISH, FINISHED FLEX FLEXIBLE FLR FLOOR, FLOORING FLUOR FLUORESCENT FO FACE OF, FINISHED OPENING FOIL FURNISHED BY OWNER/ INSTALLED BY CONTRACTOR F010 FURNISHED BY OWNER/ INSTALLED BY OWNER OOF FVIC FURNISHED BY VENDOR) INSTALLED BY CONTRACTOR SUITE NUMBER: 676 LEASE AREA: 4,400 SF OCCUPANCY GROUP: M, Mercantile CONSTRUCTION TYPE: LIB SEISMIC DESIGN CATEGORY: D SPRINKLERED: YES, MODIFICATIONS REQUIRED FIRE ALARM SYSTEM: YES, MODIFICATIONS REQUIRED PROPERTY OWNER: ARCHITECT: WESTFIELD SOUTHCENTER GRAPHITE DESIGN GROUP, LLC 2800 SOUTHCENTER MALL 1809 7TH AVE SOUTH, STE 700amazon SEATTLE, WA 98188 SEATTLE, WA 98101 CONTACT: EMAY YEE CONTACT: MATT MAREK PHONE:773.372.0565 PHONE: 206-519-5132 EMAIL: emily.yee@urw.com EMAIL: matt.marek@graphitedesigngroup.com TENANT: AMAZON CORPORATION, LLC PO BOX 81226 MECHANICAL/PLUMBING/ELECTRICAL: -' 'IONS IIIIII.°Hd7 'tl W twos In '" "' `' "'4 °'O inn rev;. ARCHITECT OF RECORD G R A P H I T E Graphite Design Group, LLC 1809 7th Ave #700 Seattle, WA 98101 206.224.3335dsiq ra hl g g p g p tedesi n rou .com SCOPE OF F WORKOr INTERIOR TENANT IMPROVEMENT OF A SHOPPING MALL SPACE FOR A RETAIL USE. WORK INCLUDES DEMO OF PREVIOUS TENANT WORK, STOREFRONT MODIFICATIONS, INTERIOR PARTITIONS, INTERIOR DOORS, SUSPENDED CEILINGS, LIGHTING, FINISHES, FURNITURE, CASEWORK AND ASSOCIATED MECHANICAL, ELECTRICAL, PLUMBING, &SECURITY SYSTEMS. SEATTLE, WA 98108-1226 M ENGINEERING 750 BROOKSEDGE BLVD PRIMARY CONTACT: WESTERVILLE, OH 43081 S 0 U T H C E N T E R revlew 3, roval su1, co err r enR 2800 SOUTHCENTER Isj41 A L assr�S Approval vas of Cony,rucf o oou?ertL1B � , } as ll�arsze the y,D.a.sOn of ary sooTtetl Coil or u a€:anC Remp, al =raven Fie b m and _ + E/\TrLE\/VJ.\98188;�C DESIGN MANAGER: CONTACT: BRENT McCLURE CONNECT: CYANNA 3 DIRAIMO EMAIL: 614Iure@ en EMAIL: bmclure men ineeus.comPlan PHONE: 206.604.3343 @ 9 9•'� EMAIL: annad amazon.com cY @ CONSTRUCTION MANAGER: SEPARATE PERMITS FIRE SPRINKLER MODIFICATIONS FIRE ALARM MODIFICATIONS CONTACT: KIRK BREWER PHONE:206.348.7766 EMAIL: it rew amazon.com 21 t, �. t 5 , y L s �,c �. APPLICABLE CODES GENERAL NOTES RESPONSIBILITY MATRIX DRAWING INDEX CONSULTANT T n F'ARA PERMIT yRG UIR D FOR. Mechar;c.! Plumbing vas Piping 2 Gas City of Tukwila BUILDING DIVISION JURISDICTION: CITY OF TUKWILA BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE ELECTRICAL CODE: THE WASHINGTON CITIES ELECTRICAL CODE MECHANICAL CODE: 2015 INTERNATIONAL MECHANICAL CODE PLUMBING CODE: 2015 UNIFORM PLUMBING CODE FIRE CODE: INTERNATIONAL FIRE CODE ENERGY CODE: 2015 WASHINGTON STATE ENERGY CODE ACCESSIBILITY CODE: 2010 ADA GUIDELINES ZONING CODE: CITY OF TUKWILA ZONING CODE 1. THE CONTRACT DOCUMENTS, WHICH INCLUDE THE AGREEMENT, GENERAL CONDITIONS, DRAWINGS AND SPECIFICATIONS, ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY OWNER OF DISCREPANCIES PRIOR TO START OF CONSTRUCTION. 2.THROUGHOUT THIS SET OF DRAWINGS, THE TERM "OWNER" REFERS TO THE "TENANT'. THE TERM LANDLORD"" REFERS TO THE "PROPERTY OWNER". 3.VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF WORK. NOTIFY OWNER OF DISCREPANCIES PRIOR TO COMMENCMENT OF WORK. 4. SECURE AND PAY FOR BUILDING PERMIT, TRADE PERMITS, FEES, LICENSES, AND INSPECTIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION NECESSARY FOR PROPER EXECUTION AND COMPLETION OF THE WORK, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING THE NECESSARY BUILDING PERMITS TO COMPLETE THE CONTRACTED WORK- THE GENERAL CONTRACTOR SHALL DETERMINE IF THE WORK REQUIRES ANY DEFERRED SUBMITTALS WITH THE JURISDICTION. DO NOT SCALE DRAWINGS. 5.OBTAIN A COPY OF THE TENANT CRITERIA MANUAL FROM THE LANDLORD AND COMPLY WITH APPLICABLE REQUIREMENTS. NOTIFY OWNER OF DISCREPANCIES PRIOR TO START Of CONSTRUCTION. 6. PRIOR TO DELIVERY DATES COORDINATE USE OF SERVICE ELEVATOR FOR DELIVERY OF MATERIALS TO THE SPACE WITH THE LANDLORD. CONFIRM CAB SIZE, CLEAR DOOR OPENING WIDTH AND LOADING WEIGHT CAPACITY WITH LANDLORD. 7. CONSTRUCTION PERSONNEL MUST CARRY PROPER IDENTIFICATION AT ALL TIMES. 8, ALL WINDOWS AND DOORS TO BE KEPT CLOSED IN THE WORK AREA. 9. WORK TO CONFORM WITH LATEST EDITION OF LOCAL, STATE AND FEDERAL CODES, AS WELL AS APPLICABLE RULES AND REGULATIONS. 10. VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION Of THE WORK AND NOTIFY OWNER OF ANY DISCREPANCIES PRIOR TO STARTING WORK. 11. UPON COMPLETION OF PROJECT, OBTAIN FINAL INSPECTIONS AS REQUIRD BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY- 12. NO WORK TO COMMENCE UNTIL PLANS HAVE BEEN APPROVED BY LANDLORD AND PERMITS HAVE BEEN ISSUED BY ALL AUTHORITIES HAVING JURISDICTION. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UON. 13.DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UON. 14. MAINTAIN CLEANLINESS OF WORK AREA AND COMMON SPACES DURING CONSTRUCTION. 15. PROVIDE FIRE EXTINGUISHERS PER SPECIFICATIONS. EXACT QUANTITY AND LOCATION TO BE COORDINATED WITH THE FIRE MARSHAL AND OWNER ON SITE PRIOR TO INSTALLATION. PROVIDE LOCATION MARKERS A5 REQUIRED BY FIRE MARSHAL. FURNISH INSTALL SHEET PERMIT SET NUMBER SHEET NAME 10.18.19 2Electrical o W o o W o A-001 GENERAL INFORMATION ! z Z 3 z u z Z 3 z w v A-011 --- FIXTURE SCHEDULES • ITEM g u, > > A-012 GRAPHICS &FINISH SCHEDULES • 01 BARRICADE • • A-1, EGRESS PLAN & CODE DATA ! SEAL 02 DEMOLITION 03 TEMPORARY WATER • • • A-121 — DEMOLITION PLAN • 04 TEMPORARY POWER • • A-131 CONSTRUCTION & FINISH PLAN • 05 TEMPORARY LIGHTING • • A-141 ---- FURNITURE / EQUIPMENT PLAN • 06 DUMPSTERS • • A-151 REFLECTED CEILING PLAN • 07 DAILY/WEEKLY CLEANUPS — • • A-201 STOREFRONT ELEVATIONS • SYMBOLS 08 FINAL CLEAN UP • • A-401 TOILET ROOM • 09 PERMIT AND APPROVAL • •- A-601 DOORS • 10 INSPECTION/COORDINATION • • A-701 INTERIOR ELEVATIONS PROJECT NORTH NORTH ARROW•CONN TRUE NORTH ELEVATION ,�y Y BUILDING LEVEL (( ) J �� @.--jiDBL GRIDLINE i X BUILDING ELEVATION A0.00 1 1 A0.00 1 INTERIOR ELEVATION 1 SIM 1 BUILDING SECTION A0.00CHECK 1 SIM I DETAIL SECTION 11 SHOP DRAWINGS 12 SPECIAL INSPECTIONS • • — — • • A-801 INTERIOR DETAILS • ! 13 CONCRETE SLAB X-RAY • • A-802 - INTERIOR DETAILS • CONCRETE SLAB -NEW • •14 • A-803 INTERIOR DETAILS • 15 SITEWORK BEYOND LEASE LINE 16 STOREFRONT • __ • • • ! E-001 E-002 ELECTRICAL SYMBOLS AND ABBREVIATIONS TECHNOLOGY SYMBOLS AND ABBREVIATIONS • • 17 FRONT ENTRANCE DOOR(S) •• •• E-011 LIGHTING SCHEDULES AND DETAILS • •335 RE WATNtFEw t. gp«gpy 18 REAR EXIT DOOR • • E-021 PANELBOARD SCHEDULES • 19 INTERIOR DOORS 20 NEW INTJEXT DOOR HARDWARE 21 DOOR LOCKS • • • • • • • E-131 E-141 — ELECTRICAL POWER PLAN TECHNOLOGY AND RC PLAN • • 22 DOOR LOCK CORES • • E-151 ELECTRICAL LIGHTING PLAN • 23 DEMISING WALL FRAMING • • E-401 ONE -LINE, SCHEDULES, AND CALCULATIONS • 24 DEMISING WALL GYP BD FURRED WALLS/MTL BAC_ KING/FRT BLOCKING 26 PARTITIONS &CEILINGS 27 FINISHES: SEE FINISH SCHEDULE 28 FIXTURES/CASEWORK: SEE FIXTURE SCHEDULES • • • • • • • • E-501 E-511 E-512 E 513 E-601 ELECTRICAL DETAILS TECHNOLOGY DETAILS TECHNOLOGY DETAILS TECHNOLOGY DETAILS _ ENERGY • • ! - • SO UTH CENTER 2800 SOUthtenter Mall Seattle, WA 98188 i 6 29 MILLWORK • • COMPLIANCE FORMS ! 30 STOCK SHELVING • • E-801 BUSSTRUT REFERENCE DRAWING • 31 MISC EQUIPMENT/FIXTURES (SEE BOH SCHEDULE) • • E-802 BUSSTRUT REFERENCE DRAWING — i — 32 SIGNAGE/GRAPHICS: SEE GRAPHICS SCHEDULE E-803 BUSSTRUT REFERENCE DRAWING i 33 BUSSTRUT SYSTEM • • E-804 —_ BUSSTRUT REFERENCE DRAWING • 34 BUSSTRUT SUSPENDED LIGHT FIXTURES &LIT EXIT SIGNAGE • • E-805 BUSSTRUT REFERENCE DRAWING • 35 NON-BUSSTRUTLIGHT FIXTURES & LIT EXIT SIGNAGE • • M-001 MECHANICAL NOTES AND SCHEDULES • 36 MEP/TECHNOLOGY: SEE MEP & TECH DWGS M-131 — — MECHANICAL PLAN 37 NETWORKING SHELL 38 J-BOXES (SEE MEP AND TECH DWGS) 39 PRICE TAG GATEWAYS • • • — • • • - M-501 — P-001 — — MECHANICAL DETAILS AND CALCULATIONS PLUMBING NOTES AND SCHEDULES __- Fig --- �rr 40 LTE EXTENSION CABLES • T • P-131 PLUMBING PLAN 41ANTENNAS 42 MUSIC SYSTEM 43 MECHANICAL UNITS • • • • • • P-501 OWNER VENDOR VENDOR PLUMBING DETAILS CONTACT LIST SCOPE CONTACT PHONE ! _-- EMAIL t b ` a- r^ a . c OCT 2 O„ 9 /� \'� t'j �J ty of �L 7 ,0 )IL. 4�.a ,�,f , "?v 44 MECHANICAL EQUIPMENT &CONTROLS •• • POINT RFID STEVEN KING 45 PLUMBING FIXTURES • • 856 384 2475 --.---— STEVEN.KING.CHECKPT.COM 46 PLUMBING EQUIPMENT & INSULATION • • HILTON SIGNAGE BRIAN 864 4201339 BRIANBAUGHMAN 47 RESTROOM ACCESSORIES • • BAUGHMAN @ HILTONDISPLAYS.COM 48 FIRE SPRINKLER • • TBD ARTWORK COLIN 49 FIRE ALARM •• • RAINIER /IN-STORE GRAPHICS DICKINSONi 425 981 1216 COLIND@RAINIER.COM A0.00 �� SIM A0.00 \r---. DETAIL CALLOUT ' , ROOM NAME I 101 ROOM NAME / NUMBER 150 SF(NET) / ROOM AREA PROPERTY CORNER OR DIM POINT DHPACE CORES BRYAN FIELDS 816 480 2464 BRYAN.FIELDS@DHPACE.COM DENALI NETWORKING SHELL DANIEEXIST WARDLLE 206 766 0468 DWARD@DENALIAI.COM ISSUED/REVISED DATE PERMIT SET 10.18.19 M Ti! ` TI:_fe..,, I ED f ITY OF "{' ys } 'ILA+} {�{, ` 2019 22 _ PERMIT CENTER ANIXTER TECH EQUIPMENT MIRANDA GRIFFITH 206 394 9221 _...... MIRANDA GRIFFITH@ANIXTER.COM SITE MAP VIRA... FIXTURE SUPPLIER DON CRONK 817 552 2575 DCRONK@VIRAIN$IGHT.COM MALL VICINITY MAP MADIX INC. FIXTURE SUPPLIER SCOTT HUFFAKER 208 870 0583 SHUFFAKER@MADIXINC.COM I x t� y c i_ BOSTON BARRICADE BARRICADE ANGELA CURRY 772 2571327 ACURRY BOSTONBARRICADE.COM �° ~ �' 1NYDREE .. FLOORING WOOD FLO SUPPLIER 1ASON BRUBAKER 404 409 7768 /BRUBAKER@NYDREE.COM uoY srrteM t macys �— �° D � p --- _— _ ", GC VENDOR CONTACT LIST _ ' 4l VENDOR SCOPE CONTACT PHONE EMAIL NEW CONSTRUCTION t YY � ""� , •e,' MOOD MEDIA MUSIC SYSTEM KARINA COOPER 512 583 8688 KARINA.000PER@MOODMEDIA.COM — PERMIT SET 10.18.19 .........--- � �y P � � � n - -- ° ___ ❑ a - o o - _ . — -may INFORMATION J—OO11 1 E i j I DHPACE HARDWARE JEFF CURTIS 303 356 3144 JEFF-CURTIS@DHPACE.COM EXISTING TO REMAIN _ — EXISTING TO BE REMOVED r o 0 ° o ` A ` - + a s MALL LOCATION UNTIED TILE TILE LISA ANDERSON RSON 425 264 2952 LISA@UNITEDTILE.COM c ., :. _ ?GENERAL a;`,; ` `- SHERWIN WILLIAMS PAINT BRIAN KEIL 425 623 2017 X 1� — BRIAN.KEIL@SHERWIN-COM e v 3 , J� ' '�"' N ' ❑ � // C ,•l -- 1-HOUR FIRE RATED CONSTRUCTION • i� t : ' " ; ; IA Ci4i # II . .ill- WILSONART GC -PR GC -PROVIDED MILLWORK FIXTURES HAZEL STRICKON 206 321 3294 STRICKH@WILSONART.COM 411111111100411.1101100411111410111111111111 2-HOUR FIRE RATED CONSTRUCTION — — LEASE LINE .yt ; '�`- •"�� "' BUSSTRUT LIGHTING AND OVERHEAD POWER DISTRIBUTION MICHAEL GELLERT 6149338695 X1000 MGELLERT B @ USSTRUT.COM \ - — TENANT LOCATION SUITE 535 Copyright ©2019 Graphite Design Group, LLC ABBREVIATIONS GENERAL MECHANICAL SYMBOLS PLUMBING AND PIPING SYMBOLS PROJECT GENERAL NOTES OWNER 0 ABV AC AD ADD AFF AFUE ALT AP ARCH BFF BLW BTU BTUH CAP CB CFM CLG CO CW DB DIA DN DW EA EAT ELEC EQUIP EWC EWT E/A EXIST FCC FD FD FDV FL FO FOV FOR FOS FPM FS FT FTR GAL GC GPM GW HB HP HTG HTR HW HYD ID IN INV LB LB/HR LAT LP LPG ROUND ABOVE AIR CONDITIONING AREA DRAIN ADDENDUM ABOVE FINISHED FLOOR ANNUAL FUEL UTILIZATION EFFICIENCY ALTERNATE ACCESS PANEL ARCHITECT/ARCHITECTURAL BELOW FINISHED FLOOR BELOW BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR CAPACITY CATCH BASIN CUBIC FEET PER MINUTE CEILING CLEAN OUT COLD WATER DEGREE DRY BULB DIAMETER DOWN DISTILLED WATER EACH ENTERING AIR TEMPERATURE ELECTRICAL EQUIPMENT ELECTRIC WATER COOLER ENTERING WATER TEMPERATURE EXHAUST AIR EXISTING DEGREES FAHRENHEIT FLOOR CLEAN OUT FLOOR DRAIN FIRE DAMPER FIRE DEPARTMENT VALVE FLOOR FUEL OIL FUEL OIL VENT FUEL OIL RETURN FUEL OIL SUPPLY FEET PER MINUTE FLOOR SINK FOOT/FEET FIN TUBE RADIATION GALLON GENERAL CONTRACTOR GALLONS PER MINUTE GREASE WASTE HOSE BIB HORSE POWER HEATING HEATER HOT WATER HYDRANT INDIRECT INCH INVERT POUND POUNDS PER HOUR LEAVING AIR TEMPERATURE LOW PRESSURE LIQUEFIED PETROLEUM GAS LVR LOUVER LINT LEAVING WATER TEMPERATURE M/A MIXED AIR MAX MAXIMUM MBH ONE THOUSAND BTU PER HOUR MCF ONE THOUSAND CUBIC FEET MD MOTORIZED DAMPER MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MTR MOTOR MU/A MAKE-UP/AIR NC NOISE CRITERIA NC NORMALLY CLOSED NIC NOT IN CONTRACT NO NUMBER NO NORMALLY OPEN NTS NOT TO SCALE 0 OXYGEN 0/A OUTSIDE AIR ORD OVERFLOW ROOF DRAIN PD PRESSURE DROP PIV POST INDICATOR VALVE PLBG PLUMBING PRESS PRESSURE PRV PSI PSIG PWR R!A RCP RD REC RED RH RUA RM RPM RW SF SIA SAN SF SD SM SP SP STM TD TDR TEMP TYP UG VAC V VAV VENT VTR W WB WCO WH PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAL POWER DUCT RISER RETURN AIR RADIANT CEILING PANEL ROOF DRAIN RECESSED REDUCER RELATIVE HUMIDITY RELIEF AIR ROOM REVOLUTIONS PER MINUTE RAIN WATER SQUARE FOOT SUPPLY AIR SANITARY SQUARE FOOT SMOKE DAMPER SURFACE MOUNT STANDPIPE STATIC PRESSURE STEAM THERMOSTAT TEMPERATURE DROP TRENCH DRAIN TEMPERATURE TYPICAL UNDERGROUND VACUUM VENT VARIABLE AIR VOLUME VENTILATION VENT THROUGH ROOF WASTE WET BULB WALL CLEAN OUT WALL HYDRANT GE REVISION NUMBER - SHOWN ON PLANS E3 POINT WHERE NEW CONNECTS TO EXISTING NUMBER OF DETAIL ON SHEET NUMBER OF SHEET WHERE DETAIL APPEARS KEYNOTE CONTINUATION SYMBOL Room ( 3 ROOM NAME AND NUMBER v= ITEM TO BE DEMOLISHED 2" AREA NOT IN CONTRACT PIPE SIZE TAG (DIAMETER) ABOVE GROUND PIPING PIPE SLOPE TAG 1/8" 112" SLOPE BELOW GROUND PIPING —INVERT: -10' -1" PIPE INVERT ELEVATION TAG E)— EXISTING PIPE TAG PIPING BEING DEMOLISHED EQUIPMENT ABBREVIATIONS AC ACC ACCU AHU AS CH CT CUH CWP CHWP DBP DC DCP EF EDC ET AIR CONDITIONING UNIT AIR COOLED CONDENSER AIR COOLING CONDENSING UNIT AIR HANDLING UNIT AIR SEPARATOR BOILER CHILLER COOLING TOWER CABINET UNIT HEATER CONDENSER WATER PUMP CHILLED WATER PUMP DOMESTIC WATER BOOSTER PUMP DUCT MOUNTED COIL DOMESTIC WATER CIRCULATING PUMP EXHAUST FAN ELECTRIC DUCT COIL EXPANSION TANK EWH FCU FP GI GRV HWP HX HRU PRV RE RTU SEP SF SP UH WH ELECTRIC WATER HEATER FAN COIL UNIT FIRE PUMP GREASE INTERCEPTOR GRAVITY ROOF VENTILATOR HEATING WATER PUMP HEAT EXCHANGER HEAT RECOVERY UNIT POWER ROOF VENTILATOR RETURN/EXHAUST FAN ROOFTOP UNIT SEWAGE EJECTOR PUMP SUPPLY FAN SUMP PUMP UNIT HEATER WATER HEATER CHWR CHWS CD CWR CWS KWR HWS G PG REF-L REF-S REF-HG STM CDR CM/ CA GW IW OW PD CW— H-CW— S-CW— F-CW— RO— HW— HW 140°— HW-R— HW-R 140°- SS SHWA SHWS SD OSD CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSATE DRAINAGE CONDENSATE WATER RETURN CONDENSATE WATER SUPPLY HEATING WATER RETURN HEATING WATER SUPPLY NATURAL GAS NATURAL GAS REFRIGERANT LIQUID REFRIGERANT SUCTION REFRIGERANT HOT GAS STEAM CONDENSATE RETURN CONDENSATE RETURN COMPRESSED AIR COLD WATER HARD COLD WATER SOFT COLD WATER FILTERED COLD WATER REVERSE OSMOSIS WATER HOT WATER HOT WATER 140° HOT WATER RETURN HOT WATER RETURN 140° GREASE VENT GREASE WASTE INDIRECT WASTE OIL VENT OIL WASTE PUMP DISCHARGE SANITARY VENT SANITARY SEWER SOLAR HOT WATER RETURN SOLAR HOT WATER SUPPLY STORM DRAINAGE OVERFLOW STORM DRAINAGE WATER CLOSET - WALL HUNG -ADA PIPE ACCESORY TAG o o er a" wCQ PIPE DROP 4" 4" 2" PIPE RISE i ✓ - PLUG PIPE TEE / REDUCING 45 4" CAP DEGREE TEE 45 DEGREE TEE PIPE ACCESSORY TAGS 2" DO. WM DOMESTIC WATER METER 2" BALANCING .�BALANCING VALVE —2" SHUTOFF 1/4 TURN BALL VALVE 2" CHECK .-- - CHECK VALVE " M-CNTRL •�' MOTORIZED CONTROL VALVE 2" 3-WAY CNTRL 3 WAY MOTORIZED CONTROL VALVE 2" PRV PRESSURE REDUCING VALVE 318" SOLENOID le --REFRIGERANT SOLENOID VALVE 2" TMV 2" BUTTERFLY 3-WAY MIXING VALVE /./BUTTERFLY VALVE DRAIN TAGS DRAIN SIZE FLOOR DRAIN 0-.-{ 4" FD-1 J-.-TYPE (SEE SCHEDU� AD-6 AREA DRAIN FLOOR DRAIN w { 4" FD-3P }-� "P" -INDICATES ( 4" SD-29 J-► 03- DECK DRAIN PRIMER CONNECTION FLOOR SINK E -t 4" FS-4 HUB DRAIN 8 WFU - --FIXTURE UNITS 4" SD-12 FLOWDRAIN CONTROL ---- i 4" SD-15 ] STORM DRAIN ROOF AREA (-6" SD-1 J PLUMBING FIXTURE TAGS SERVED BY DRAIN SF TYPE (SEE SCHEDULE) LAV-1 FIXTURE UNITS-1.5 CWFU 1.5 HWFU LAVA WC-1A J , we-1 1 1 WFU 0 COMBINATION DRAINS CO NOTE * ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN THIS SET. THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS. FLOOR DRAIN SCHEDULE ID FD-1 DESCRIPTION FLOOR DRAIN MANUFACTURER MODEL MATERIAL DESCRIPTION WASTE REMARKS DRAIN BODY STRAINER PIPE SIZE SPECIFICATION WATTS FD-100 A EPDXY COATED CAST IRON NICKEL BRONZE 3" 1 EPDXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE, REVERSIBLE CLAMPING COLLAR WITH 1 PRIMARY 8 SECONDARY WEEPHOLES, ADJUSTABLE ROUND HEEL PROOF NICKEL BRONZE STRAINER, AND NO HUB OUTLET. DOMESTIC FIXTURE SCHEDULE ID DESCRIPTION MANUFACTURER MODEL TRIM FLOW FIXTURE [-- FLUSH FIXTURE � COLD WATER ROUGH -IN PIPE SIZE HOT WATER ROUGH -IN PIPE SIZE SPECIFICATION MATERIAL DESCRIPTION ' FINISHMANUFACTURER MODEL , TYPE ____-- MOTION SENSOR CONTROL COLD WATER WATER FLOW TEMP. HOT MAX. MIXED'' VENT WATER WATER VOL. PER MIN VOL. WASTE PIPE PIPE TEMP. TEMP. FLUSH i PER FLUSH DIAMETER j SIZE EWC-2 JS 1 WATER COOLER JANITOR SINK ELKAY STERN WILLIAMS EZSTLSC MTB-2424 GALVANIZED STEEL STAINLESS McGUIRE LF2165CC STEEL CABINET I MANUAL No 0.1 GPM 40 °F 40 °F j 2" 1-1/2" 1/2" 3/4" 3/4" WALL MOUNTED, LEAD FREE, BARRIER FREE, BI LEVEL DRINKING FOUNTAIN WITH FRONT AND SIDE ACTIVATED PUSH BARS, STAINLESS STEEL BOWL, FLEXIBLE SAFETY BUBBLER. 8 GALLON PER HOUR CHILLER CAPACITY. PROVIDE WITH McGUIRE LF2165CC BRASS COMPRESSION ANGLE STOP VALVE WITH RISER AND ESCUTCHEON, McGUIRE B8912CF ADJUSTABLE P-TRAP AND WASTE ARM WITH CLEANOUT PLUG AND ESCUTCHEON, AND SUITABLE CARRIER. 120 VOLT, 4 FULL LOAD AMPS. SERVICE BASIN WITH INTEGRAL STAINLESS STEEL DRAIN BODY. PROVIDE WITH CHICAGO FAUCET 897-CP WITH WALL BRACE, INTEGAL VACCUUM BREAKER, PAIL HOOK, AND 3/4" MALE HOSE THREADED OUTLET. FURNISH WITH 3' LONG REINFORCED HOSE WITH 3/4" CHROME COUPLING AND WALL HOOK, EXTRUDED VINYL BUMPER GUARD AND STAINLESS STELL MOP HANGER. MOLDED STONE CHICAGO FAUCET CO 1 897-CP MANUAL No 2.5 GPM 40 °F 140 °F 140 °F 3" — 1 LAV-LAVATORY -WALL HUNG - ADA KOHLER K-2084 "SOHO" WHET ITE VITREOUS CHINA WHITE CHICAGO FAUC CO 3500-E2805A BCP MANUAL No 0.5 GPM 40 °F 140 °F 105 °F 2" — 1/2" 1/2" 20" x 18" RECTANGULAR WALL MOUNTED FIXTUREWITH FAUCET LEDGE AND OVERFLOW, SINGLE FAUCET HOLE AND SOAP DISPENSER HOLE. PROVIDE THERMOSTATIC MIXING VALVE LEONARD 170-LF, SOLID LEAD FREE, SET TEMPERATURE TO 110 DEGREE F, ASSE APPROVED. PROVIDE McGUIRE 155A GRID DRAIN, McGUIRE LF2165CCLK ANGLE STOP VALVES, McGUIRE B8872CF P-TRAP. PROVIDE PLUMBERX "PRO -EXTREME" X-4222 INSULATION KIT. WC-1 WATER CLOSET - FLOOR MOUNT - TANK TYPE - ADA AMERICAN STANDARD CADET PRO 215AA.104 WHITE VITREOUS CHINA WHITE CHURCH 9500SSCT MANUAL No imi - 40 °F 40 °F 1.28 gal 1.28 gal 4" 2" 1/2" ELONGATED FLOOR MOUNTED TANK TYPE WATER CLOSET, 1.28 GALLON PER FLUSH WITH SIPHON JET ACTION, SIDE MOUNTED CHROME TRIP LEVER. WITH CHURCH 9500SSCT ELONGATED OPEN FRONT SEAT, SOLID PLASTIC HEAVY DUTY SEATLESS COVER WITH SELF-SUSTAINING CHECK HINGES AND STAINLESS STEEL BOLTS. PROVIDE McGUIRE LF2166CC ANGLE STOP VALVE. ELECTRIC WATER HEATER SCHEDULE ID 1 MANUFACTURER MODEL NO. ELECTRIC HEAT EXCHANGER VOLT PH REMARKS HEATING CAP WATERSIDE STORAGE RECOVERY j VOL EWH-1 AOSMITH DEL-15 3.0 kW 14.0 GPH 1 15.0 gal 208 V t SET OUTLET TEMPERATURE TO 140 F. DOMESTIC EXPANSION TANK SCHEDULE ID ET-1 MANUFACTURER AMTROL MODEL I ST-5-C 1 TANK VOLUME 2.1 gal ACCEPTANCE VOLUME i 0.9 gal 1 PRESS RELIEF 150 psi DIMENSIONS UNIT WEIGHT REMARKS DIAMETER ! HEIGHT 0' - 8" i 1' -1" 10 lb PROJECT GENERAL NOTES * REMOVE ALL UNUSED PIPING, DUCTWORK AND ACCESSORIES. * THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING, PRIOR TO FINAL BID, ALL EXISTING CONDITIONS FOR PLUMBING AND MECHANICAL SYSTEMS WITHIN TENANT SPACE AND WITHIN CLOSE PROXIMITY OF TENANT SPACE. * THE MECHANICAL CONTRACTOR SHALL PERFORM SERVICE AND REPAIR ON THE EXISTING EQUIPMENT AND ITS ACCESSORIES AS FOLLOWS: CLEAN ALL COILS, REPLACE THE FILTERS AND BELTS, INSPECT, REPAIR, OR REPLACE THE ECONOMIZERS, DRIVES AND FAN BEARINGS, MOTORS, CONTROL COMPONENTS, VALVES AND ANY OTHER ITEM NECESSARY FOR A COMPLETE AND PROPER OPERATING SYSTEM. THIS CONTRACTOR SHALL ALSO VISIT THE SITE, PRIOR TO FINAL BIDDING, AND VERIFY ALL EXISTING SITE CONDITIONS. PROVIDE ALL MATERIAL AND COMPONENTS AS NEEDED TO BRING THE UNITS TO FULL COMPLIANCE OF THE LANDLORD'S CRITERIA AND LOCAL AUTHORITY HAVING JURISDICTION. * WHERE FLOOR DRAINS OCCUR WITHIN THE LIMITS OF CONSTRUCTION, PREVENT CONSTRUCTION DEBRIS FROM ENTERING DRAIN BODY BY SEALING DRAIN OPENING PRIOR TO START OF WORK. * COORDINATE INSTALLATION OF PIPING, DUCTWORK, CONDUIT, LIGHTS, CABLE TRAY, STRUCTURE, AND EQUIPMENT TO PREVENT CONFLICTS. * THE CONTRACTOR SHALL BE FAMILIAR WITH ALL THE CONDITIONS BOTH EXISTING AND THOSE ILLUSTRATED BY THESE DOCUMENTS AS WELL AS THOSE WHICH CAN BE REASONABLY ANTICIPATED INCLUDING, BUT NOT LIMITED TO ARCHITECTURAL, ELECTRICAL, VENTILATION, PLUMBING, AND OTHER SYSTEMS INVOLVED ON THIS PROJECT. * FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM, AND SHALL CONFORM TO ALL REQUIREMENTS OF APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING BUT NOT LIMITED TO THE INTERNATIONAL BUILDING CODE AND INTERNATIONAL MECHANICAL CODE. * LOCATE EQUIPMENT REQUIRING ACCESS 2'-0" MAXIMUM ABOVE CEILING. * ALL ROOF MOUNTED EQUIPMENT SHALL BE A MINIMUM 10'-0" FROM EDGE OF ROOF. * LOCATE DUCTWORK, PIPING AND MECHANICAL EQUIPMENT AWAY FROM THE SPACE ABOVE ELECTRICAL PANELS. TRANSFORMERS AND OTHER ELECTRICAL EQUIPMENT. * FIRE SEAL AROUND DUCT AND PIPING PENETRATIONS OF FIRE RATED WALLS. REFER TO SPECIFICATION. * PROVIDE SLEEVES AND/OR OPENINGS TO RUN PIPES AND DUCTS THROUGH FOUNDATIONS, FLOORS, WALLS, AND ROOF. * ADJUST PIPING AND DUCTWORK SIZES TO PROPERLY CONNECT TO MECHANICAL EQUIPMENT. * REFER TO PLUMBING SERIES DRAWINGS FOR GAS AND A.C. CONDENSATE DRAIN PIPING. * PIPE SIZES SHOWN SHALL BE CONTINUED IN THE DIRECTION OF FLOW UNTIL ANOTHER SIZE IS SHOWN. * FOR DETAILS, EQUIPMENT CONNECTIONS, AND PIPE SIZES NOT SHOWN ON THE SEGMENTS, REFER TO DETAILS, SCHEDULES, AND SPECIFICATIONS. * INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE RESPECTIVE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS, AT A LEVEL OF QUALITY AND WORKMANSHIP CONSISTENT WITH THE SPECIFICATIONS. * LOCATIONS OF PIPING, DUCTWORK AND EQUIPMENT AS INDICATED ON THE DRAWING, ARE APPROXIMATE AND SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD. WORK SHALL BE COORDINATED WITH ALL OTHER TRADES TO AVOID INTERFERENCE IN THE FIELD. * INSTALL EXPOSED PIPING AND DUCTWORK AS HIGH AS PRACTICAL IN ROOMS WITHOUT CEILINGS. * FIRE PROTECTION NOTE FIRE PROTECTION DRAWINGS SHALL BE PROVIDED UNDER A DEFERRED SUBMITTAL. GENERAL CONTRACTOR SHALL HIRE LANDLORD APPROVED FIRE PROTECTION CONTRACTOR TO CREATE AND SUBMIT FIRE PROTECTION DRAWINGS AND CALCULATIONS TO THE BUILDING DEPARTMENT. FIRE PROTECTION CONTRACTOR SHALL PERFORM ALL NECESSARY WORK AS REQUIRED TO PROVIDE A COMPLETE FIRE PROTECTION SYSTEM TO MEET ALL LANDLORD REQUIREMENTS, CODE REQUIREMENTS AND AUTHORITIES HAVING JURISDICTION. PLUMBING GENERAL NOTES PLUMBING GENERAL NOTES * FIELD VERIFY ALL NEW WATER, WASTE, AND VENT PIPING CONNECTIONS AND PROVIDE NEW CONNECTIONS AS REQUIRED FOR PROPERLY OPERATING SYSTEMS. PITCH UNDERFLOOR SANITARY WASTE AND STORM PIPING 3" AND GREATER AT 1/8" PER FOOT, UNLESS NOTED OTHERWISE. PITCH ALL OTHER WASTE PIPING AT 1/4" PER FOOT UNLESS OTHERWISE NOTED. * FIELD VERIFY LOCATION AND INVERTS OF SITE UTILITIES PRIOR TO INSTALLATION. * ROUTE DOMESTIC WATER, FIRE PROTECTION, SANITARY SEWER, AND STORM SEWER SERVICES TO SITE UTILITIES 5'-U" FROM BUILDING UNLESS NOTED OTHERWISE. REFER TO CIVIL PLANS. * WASTE AND VENT PIPING BELOW FLOOR AND THROUGH FLOOR SHALL BE 2" MINIMUM. * PROVIDE CLEANOUT IN ACCESSIBLE LOCATION AT THE BASE OF ALL PLUMBING RISERS. PErt I (I Ca CITY vr,it OCT 22 2019 PERMIT CENTER amazon GRAPHITE Graphite Design Group, LLC 1809 7th Ave #700 Seattle, WA 98101 206.224.3335 graphitedesigngroup.com CONSULTANT M-Engineering M-Engineering 750 Brooksedge Blvd. Westerville, 0H 43081 614-839-4639 www.mengineering.us.com SEAL 182019 SOOTHCENTER 284Southcenter Mall Seattle, WA 98188 FOR USE BY AHJ ISSUED/REVISED DATE City Project Status: CDs 10/18/2019 PLUMBING NOTES AND SCHEDULES P-001 Copyright © 2019 Graphite Design Group, LLC FIELD VERIFY ALL CONDITIONS KEYNOTES OWNER LAV-1-C WC-1 L 4S-1 [3" T evZi 1 2" VTR ENLARGED SANITARY PLAN EWC-2 P-13 1/4" = 11-01' 2" VTR 1 2" V \_2„v 4" SS 3/4"CW 1/2" V „ 1 2, V ---. , 1.< I 1 -1 3" FD-1 4" SS LEWC-2 JS-17 SS 4" SS 2" SS /1 3" SS SS 2"V 3" SS /2" V 1,— 11/2" V LAV-1 2" SS ETV —CID C-371?-1 N- 4" FCC, WASTE AND VENT ISOMETRIC 3/4" CW ET-1 1/2" CW—A 3/4" CW [WC-1 LEW_Di2j 410 4Nti„ 3/4" CW 0 44000.01/2"HW /2"CW 3/4,W EYVH-1i lAa—) HS-1 -)1 1/2" CW jWC-1 DOMESTIC WATER RISER 1/2" CW 1/2" HW P6 (TYP.) 3/4"CW (p4) LAV-1 JS-1 ) _ (TYP.) 4-- 1 WC-1 EWH-1 (TSP.) EWc-72—) ENLARGED DOMESTIC WATER SUPPLY PLAN 1/4" = 1,0" TRAP SEAL PRIMERS No form of trap that depends for its seal upon the action of movable parts shall be used. Each fixture trap shall have a liquid seal...and shall be protected from freezing. Floor drain or similar traps directly connected to the drainage system and subject to infrequent use shall be protected ,vith a trap seal primer. Trap seal primers shall be directly connected to the water supply and shall be accessible for maintenance. (2015 UPC 1005.0. 1006.0 & 1007.0) PLUMBING PLAN DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIA. NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHInCT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACT°. SHALL HAVE A WORKING KNOWLIDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT -IES BERVEEN-GOVERMING COIHS-AND-DES.N.ffENT: P1 P2 P3 P4 P5 P6 DO NOT ROUTE PIPING ABOVE ELECTRICAL EQUIPMENT. CONNECT NEVV SANITARY TO EXISTING SANITARY MAIN. FIELD VERIFY LOCATION AND ELEVATION OF EXISTING SANITARY MAIN LANDLORD'S REPRESENTATIVE PRIOR TO ROUGH -IN. PROVIDE CLEANOUT AT CONNECTION TO EXISTING MAIN LINE. EXTEND NEW 3"VENT THRU ROOF. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. ALL ROOF PENETARIONS AND REPAIR SHALL BE MADE BY THE LANDLORD'S ROOFING CONTRACTOR AT THE TENANTS EXPENSE, CONNECT NEW DOMESTIC WATER LINE TO LANDLORD'S WATER MAIN. FIELD VERIFY LOCATION AND SIZE OF LANDLORD'S WATER LINE WITH LANDLORD'S REPRESENTATIVE PRIOR TO ROUGH -IN. EXISTING CONDENSATE DRAIN TO REMAIN. CLEAN, INSPECT AND REPAIR AS REQUIRED. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. P-131 1/8" = 1'-0" IIECEiVED CITY C,F. OCT 22 2019 PERMIT CENTER amazon ARCHITECT OF RECO GRAPHITE Graphite Design Group, LLC 1809 7th Ave #700 Seattle, WA 98101 206.224.3335 graphitedesigngroup.com CONSULTANT M-Engineering M-Eng neering 750 Brooksedge Blvd. WesterviRe, OH 43081 614-839-4639 www.mengineering.us.com SEAL SOUTHCENTER 2130 Southcenter Malt Seattle, WA 98188 FOR USE BY AHJ 1SSUED/REVISED 28 2.019 ELPUT _ DATE Project Status: CDs 10/18/2019 PLUMBING PLAN P-131 Copyright © 2019 Graphite Design Group, LLC OWNER amazon PIPE --INSULATION — GALVANIZED STEEL SHIELD HIGH DENSITY PIPE RING HANGER INSULATION INSERT OR WOOD BLOCK SEE SPECIFICATIONS CLEVIS HANGER 3 INSULATED PIPE AT HANGERDETAIL NOT TO SCALE CLEAN OUT AND PLUGGED RISER NOT TO SCALE COVER PLATE VARIES AS REQUIRED BY PIPE INVERT PROVIDE PLUG AT THIS HUB IF PIPE DOES NOT CARRY THRU VACUUM BREAKER HEAT TRAP (TYLPL' CVAALL)V (TYPICAL) --- 0 DIELECTRIC — ASME TEMP. AND UNION - (TYPCAL) PRESSURE RELIEF VALVE T WH-1 CHECK VALVE — DHW DCW- 7HOF • S 3/4" SHEET METAL STRAP TO WALL FOR SEISMIC RESTRAINT. REFER TO ARCHITECTURAL DETAILS FOR ADDITIONAL INFORMATION. SET THERMOSTAT AT 140°F - PLYWOOD PLATFORM ABOVE CEILING BY GENERAL CONTRACTOR - ,P,501 ARMTROL EXPANSION TANK. (ET-1) RUN FULL SIZE TO FLOOR DRAIN, 3/4" MINIMUM DRAIN VALVE2-1. /LIG"DE EEP G) DA LRVI 4k (PAN _ 2 2 H. SEAMS SOLDERED WATERTIGHT. / / / / / (BY PLUMBING CONTRACTOR) CEILING MOUNTED WATER HEATER NOT TO SCALE 1" TO FLOOR DRAIN OR JANITOR SINK 96-11 oVo rmciv CITY )F ipPERMIT CrINTER P, ILA OCT 22 2019 ARCHITECT OF RECORD GRAPHITE Graphite Design Group, LLC 1809 7th Ave #700 Seattle, WA 98101 206.224.3335 graphitedesigngroup.com CONSLJLTANT M-Engineering M-Engineering 750 Brooksedge Blvd. Westerville, OH 43081 614-839-4639 www.mengineering.us.com SEAL SOUTHCENTER 2f3D0 Southcenter Mall Seattle, WA 98188 FOR USE BY AHJ ISSUED/REVISED DATE Project Status: CDs 10/18/2019 PLUMBING DETAILS P-501 Copyright © 2019 Graphite Design Group, LLC