HomeMy WebLinkAboutPermit PG19-0179 - COSTCO - GAS PIPING FOR NEW HEATERSCOSTCO 400 COSTCO DR PGI 9-0179 Parcel No: Address: 0 City of Tukwila Department mfCommunity Development 630OSouthoenterBoulevard, Suite #1D0 Tukwila, Washington 9818Q Phone: 206-431'3670 Inspection Request Line: 2U6-43Q'93SO Web site: http://www.TukwilaWA.gov 3523049089 Project Name: COSTCO PUUPNB|PJ PIPING PERMIT Permit Number: PGI9-0179 Issue Date: 11/27/20I9 Permit Expires On: 5/25/2020 Owner: Contact Person: Name' COSTCO VVHULESALE0RPORATIO 999LAKE DRPROPERTY TAX DEPTOU6 VVESUEGRE60RY S10ZZ0THST.E#IO2,FIFE, WA, 98424 Contractor: Name: REFRIGERATION UNLIMITED LLC ([0NST) Address: S1O2l0THSTE#1QZ'FIFE, WA, 98424 License No: REFK|UL826mH Lender: Name: ''' Phone: (253)279'220I Phone: (253)474'3100 Expiration Date; 8/22/2020 DESCRIPTION OF WORK: INSTALL GAS PIPE FOR NEW HEATERS. Valuation of Work: $18,500.00 Water District: TUKVV|LA Sewer District: TUKWILA Fees Collected: $358.85 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: ized Signature; National Electrical Code: VVACities Electrical Code: VV4C295-46B: WA State Energy Code: 05 Zl 05 21 2017 2017 2017 2015 Date: v � ^°wl' , | hearhycertify that | have read and examined this permit and know the same to betrue and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions nfany other state orlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development permit and- agree tothe conditions attached tothis permit. Signature: Print Name: /l ----------- This permit shall become null and void if the work is not commenced within 180 days for the date ofissuance, orif the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NcJmE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)438'9350 ZOOO GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING 9001 UNDERGROUND CITY OF TUKW1ti.t.1 Community Development Department Pennit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Pe it No. P67 /9 o 179 Project No. /,, Date Application Accepted: l 1 — 49— /9 Date Application Expires: 5 - Le — 2- (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: (w C©STeo Q/Z Tenant Name: C O S 7ce o0K PROPERTY OWNER Name: 10S7ev._e_ Address: 11, /A / t OR. City: I s S.Aq k.c h State: ttirq Zip - CONTACT PERSON — person receiving all project communication Name: / l S t° GAe3CI19' Address: 5702- Z,ri - 1 S7 C Al- /D Z City: / rt State: (,,/,4 Zip:c y Phone: Z5.3... )1 - Z-z,OI Fax: �sLoy7. ``9079 Email:(APs,D 6,,9eAf jw-pac. Coe' King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes No PLUMBING CONTRACTOR INFORMATION Company Name: e �1� 7/O.''. (,%, tIlirTe/, Address:5 /8 � 2 o r � ST e ° 10 - - City: rl Fe State: t,, j4 Zip: f 2Y Phone: zs3_97y-31 , Fax: c.o.- tin—yv3Cr Contr Reg No.: D Eq. rG ee Z6 oExp Date: 6 /ZZ/� r Tukwila Business License No.: Valuation of Project (contractor's bid price): $ �f 0 eo Scope of Work (please provide detailed information): Q�¢7elL 1 57.4 9A; P� lie f, Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: I-IAA.pplications\Forms-Applications On Line\2011 Applications'Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 Page 1 of 2 Indicate type of plumbing fixtures and/orpiping outlets being installed and the quantito Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets f Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: vl Print Name: �,PS Mailing Address: 570 Z Date: ///6 /� f Day Telephone: f/ 4/19 q$CZt City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of TukWila ACCOUNT QUANTITY PAID $358.85 PG19-0179 Address: 400 COSTCO DR Apn: 3523049089 $358.85 Credit Card Fee $10.45 Credit Card Fee R000.369.908.00.00 0.00 $10.45 GAS $335.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PERMIT FEE R000.322.100.00.00 0.00 $233.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $67.00 TECHNOLOGY FEE $13.40 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R19016 0.00 $13.40 $358.85 Date Paid: Wednesday, November 06, 2019 Paid By: WES GREGORY Pay Method: CREDIT CARD 22719G Printpri• \A/Prinecriav Nnvernher n6 2n19 17.25 1 of 1 CO TUKWILx ETKAKIT 6200 SUVTVCsNTER OLVD TUKwILA, WA 98188 200-4]]'1870 CITY OF TVKWILA 0017340000802374464500 Date: 11/86/2019 12:25:06 PM CREDIT CARD SALE VISA CARD NUMBER: ****+*°***5142 K TRAN AMOUNT: $358.85 APPROVAL CD: 22719G RECORD #: 800 cLcnx ID: frankie X (CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! merchant Copy COI? INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit Projec Type of Inspection: Address: Date Called: Special instructions: Date iTanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: nspec Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 4C° A''d0 Ccsi?c, Special Instructions: `T pe of Inspection: ate died: Date Wanted: /2 Requester: a.m. p.m. Approved per applicable codes. Corrections required prior to approval. COMMENT nspecto Date: REINSPECTION FEE REQUIRED. Prior to next inspection.'ee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection, City of Tukwila Department of Community Development November 19, 2019 WES DEGREGORY 5102 20TH ST. E #102 FIFE, WA 98424 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG19-0179 COSTCO - 400 COSTCO DR Dear WES DEGREGORY, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBM1I I ALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seaUstamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Remove the notes on each plan sheet "For Review Only Not for Construction". 2. Provide engineer's stamp or design professional stamp and their information of who is responsible for the gas plumbing -plan designs and calculations. See general notes including Stamps and Signatures above. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, Bill Rambo Permit Technician File No PG19-0179 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 OPERIPT MORD COO PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0179 PROJECT NAME: COSTCO SITE ADDRESS: 400 COSTCO DR Original Plan Submittal Revision # before Permit Issued DATE: 11/19/2019 X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: fo t1\141 Building Division Public Works 1-2 Fire Prevention Structural L Planning Division Permit Coordinator I PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/21/19 Structural Review Required REVIEWER'S INITIALS: DATE: LI APPROVALS OR CORRECTIONS: DUE DATE: 12/19/2019 Approved Approved with Conditions r Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) LI Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire D Ping 0 PW Ej Staff Initials: 12/18/2013 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG19-0179 DATE: 11/06/2019 PROJECT NAME: COSTCO SITE ADDRESS: 400 COSTCO DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Fire Prevention Structural H R Planning Division Permit Coordinator H I PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 11/07/19 Structural Review Required DATE: LI APPROVALS OR CORRECTIONS: Approved Corrections Required n DUE DA : 12/05/2019 Approved with Conditions ri Denied (corrections entered in Reviews) (ie: Zoning Issues) LI Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Ping 0 PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: //— El Response to Incomplete Letter # Plan Check/Permit Number: PG19-0179 Response to Correction Letter # Revision # after Permit is Issued 0 Revision requested by a City Building Inspector or Plans Examiner 0 Deferred Submittal # Project Name: COStC0 Project Address: 400 Costco Dr Contact Person: (.4...h'S ,d-P612.74-1 Phone Number: 27 Summary of Revision: tA /IS I S$F0-71- ; %j/7-F", q €6.745 $ Sheet Number(s): "Cloud" or highlight all areas of revision including dateof ision Received at the City of Tukwila Permit Center by: El Entered in TRAM' on // CAUsers\ Wes \AppData\ LocalTackages\Microsoft.Office.Desktop_8wekyb3d8bbwe\AC\INetCache\Content.OutlookU8R2NEPO1Rovision Submittal Forrn.doc • 1),,,n•rot ICP Labor & Industries (https://lni.wa.qov) Contractors REFRIGERATION UNLIMITED LLC Principals KUNTZ, ADAM LEROY, PARTNER/MEMBER Doing business as REFRIGERATION UNLIMITED LLC WA UBI No. 601 920 980 5102 20TH ST E #102 FIFE, WA 98424 253-474-3100 PIERCE County Business type Limited Liability Company Governing persons LLC ARCTICOM GROUP KURT L KNUTZ; RICK L PATRICK; SEAN PATRICK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties COMMERCIALJINDUSTRIAL/REFRIG License no. REFRIUL826NH Effective — expiration 08/22/2018— 08/22/2020 Bond . .„,. Ohio Security Ins Co Bond account no. 023024241 $12,000.00 Received by Led Effective date 08122/2018 08/15/2018 Expiration date Until Canceled Insurance National Fire Ins of Hartford $1,000,000.00 Policy no. 607636148 Received by L8,1 Effective date 10/03/2019 10/0112019 Expiration date 12/27/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. 58:03 AM, IL GAS SIZE CHART PRESSURE PRESSURE MAX DEVELOPED PSI DROP LENGTH (FEET) 2 TO 1.0 500 PIPE SIZE (UPC) MAX LOAD (MBH) 1/2" 182 3/4" 380 716 1-1/4" 1,471 1-1/2" 2,204 2" 4,244 2-1/2" 6,764 3" 11,958 4" 24,390 6" 71,449 8" 146,801 PROVIDE ONE OF FOLLOWING REGULATORS AT EACH PIECE OF EQUIPMENT WITH VENT TO OUTSIDE OR VENT LIMITER ON MAXITROL SENSUS MODEL #496 PIPE SIZE- 3/4' OR 1" ORIFICE - 3/8" SPRING - GREEN FOR GAS LOAD UP TO 760 MBH MAXITROL MODEL GAS LOAD UP TO 340 MBH 325-5L600 PIPE SIZE - 3/4" OR 1" GAS LOAD BETWEEN 340 MBH AND 1000 MBH 325-7AL2100 PIPE SIZE 1-1/4" OR 1-1/2" *ALL GAS PRESSURE REGULATORS TO BE RATED FOR 5 PSI. GAS SIZE CHART PRESSURE PRESSURE MAX DEVELOPED IN WC 7 DROP TO 6.5 LENGTH (FEET) 100 PIPE SIZE (UPC) MAX LOAD (MBH) 1/2" 45 3/4" 94 1' 177 1-1/4" 363 1-1/2" 544 2" 1,048 2-1/2" 1,672 3" 2,956 4" 6.032 ',.. 6" 17,683 8" 36,348 Kam/ 3/4"GAS DN THRU ROOF TO TRUSS SPACE Gip (0) -.. 3/4" G (355 MBH) GAS CALCULATIONS EXISTING LOAD 4,542,000 BTU/H REMOVED LOAD RH-(RELO1 -180,000 BTU/H ADDED LOAD Rooftop HVAC Equipment AC-1 60,000 AC-4 90,000 AC-10.14 1,465,000 Radiant Heaters RH-1,2 120,000 RH-3,4,5,6 320,000 RH-(RELO1 180,000 TOTAL GAS LOAD 6,142,000 BTU/H 4" FOOD SERVICE ACCEPTABLE 0 2" PSI MECHANICAL PLAN NOTES SFF MIRRr OM IR MI FOR SFECAflp rOFFR'RCR O NEW AC UNIT ON EXISTING ROOF CURB. RECONNECT GAS AND CONDENSATE WHERE APPLICABLE. FIELD VERIFY SIZE, LOCATION AND DIMENSIONS OF EXISTING AC UNIT AND CURB. VERIFY EXISTING CURB IS LEVEL PRIOR TO INSTALLATION. SCRAPE EXISTING GASKET AND ADHESIVE FROM CURB AND REPLACE WITH NEW NEOPRENE GASKET. O2 NEW AC UNIT ON ADAPTOR CURB. REPLACE EXISTING AC UNIT WITH NEW AC UNIT. INSTALL ADAPTOR ON EXISTING CURB AND NEW AC UNIT ON ADAPTOR. CONNECT GAS AND CONDENSATE WHERE APPUCABLE. FIELD VERIFY SIZE, LOCATION AND DIMENSIONS OF EXISTING AC UNIT AND CURB. SCRAPE EXISTING GASKET AND ADHESIVE FROM CURB AND REPLACE WITH NEW NEOPRENE GASKET FOR BOTH ADAPTER CURB AND NEW UNIT. ADAPTOR CURB TO BE PRE-ENGINEERED BY THYBAR OR EQUIVALENT. FOR COORDINATION WITH THYBAR CONTACT BILL MARZEC (775-343-0600) 0 THYBAR TO ORDER ADAPTOR CURBS. EXISTING STAINLESS STEEL CURBS TO BE EQUIPPED WITH STAINLESS STEEL ADAPTOR CURBS. G.C. TO SUBMIT STAMPED DRAWING FOR ADAPTOR CURB. SUBMITTAL TO INCLUDE CONNECTIONS BETWEEN EXISTING CURB & ADAPTOR CURB; AND CONNECTION BETWEEN ADAPTOR CURB & NEW AC UNIT; AND ADAPTOR CURB WEIGHT. INSTALL NEW AC UNR. MC TO LOCATE ROOF PENETRATIONS AND ROOF CURB FOR M.B.S. AND/OR G.C. PENETRATIONS SHALL BE SUCH THAT SUPPLY, RETURN AND/OR EXHAUST DUCT DROPS CAN EXTEND STRAIGHT DOWN TO CEILING SPACE OR DIFFUSER PACKAGE. RELOCATION OF ANY UNIT FROM WHERE SHOWN ON PLAN SHALL BE APPROVED BY ARCHITECT PRIOR TO UNIT INSTALLATION. COORDINATE EQUIPMENT LOCATION WITH LIGHTS, BLDG. STRUCTURE, PIPING, SWAY BRACING AND SKYLIGHTS. SEE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS. LOCATE SALES FLOOR AC UNITS BETWEEN RACKS. CENTER SUPPLY DUCT DROP OPENING BETWEEN JOISTS. REQUIRED CLEARANCE FOR ROOFTOP UNIT IS SHOWN. O EXISTING HVAC IN THIS AREA TO REMAIN, 8 INSTALL NEW SPOT ST5R.M. MC TO LOCATE NEW OUTDOOR UNIT ABOVE BEAM. MAINTAIN MINIMUM SERVICE CLEARANCE FROM EXISTING SKYLIGHTS AND UNITS. D F SETT TO BE TED AS CLOSE TO COLUMN AS POSSIBLE, UNIT CENTER OF GRAVITY TO BE ABOVE GLULAM BEAM AT COLUMN. BD- FOR HVA0''W09.F IN-7'RI? AREA, SEE "REAR IT WAREHOUSE HVAC PLAN" ON 1 1-1/4" (930 MB (E)3" ON R0 )3" nlv0 (E)4" @ 7" 0 UP TO ROOF E)6" @ 2P51 UP TO POOF O 000000 SEE DETAIL DIFFUSER TO BE MOUNTED AS CLOSE TO COLUMN AS POSSIBLE. UNIT CENTER OF GRAVITY OF TO BE ABOVE GLULAM BEAM AT COLUMN. EXISTING GRAM VENTILATOR TO B irMCVE�--R00 -- SEE DETAIL 0 3/4" GAS (195 MBH) ( 00000 DIFFUSER TO BE MOUNTED AS CLOSE TO COLUMN AS POSSIBLE UNIT CENTER OF GRAVITY OF TO BE ABOVE GLULAM BEAM AT COLUMN. j( t 001011100 EXISTING POWER VENTILATOR TO BE REMOVED ROOF OPENING TO BE CAPPED. CT 0 EX FIEL OCAT 1-1/4" G 6' 0I RIFY SI; EXISDN( OSA UN (195 MBH) 1-1/4" GAS (735 MBH) (930 MBH) 1— _ T � Ell III NMI MINI III INN Mill � �{T�4�T�'�T—�{j�— 1100% DEDICATED IT TO REMAIN, __..._ EXISTING 0/ AND -- FILTERS TO * OVED N _SET ASIDE F*' , SE. INSTALL INTA'��'� * T FOR INSTALLATION (Jy C AIL. SEE DETAIL _ (E)1-1/2" 0 2 P31 ,41 I EXISTING GRAVITY VENTILS TO BE REMOVED ROpF OPENING TO BE CAPPED. FIRE PROTECTION NOTES 1. M.C. TO DISCONNECT EXISTING DUCT SMOKE DETECTOR(S) AND RECONNECT TO NEW HVAC UNIT(S). 2. M.C. TO VERIFY OPERATION OF DUCT SMOKE DETECTOR(S) AND REPLACE AS NECESSARY. 3. FOR DUCT SMOKE DETECTORS INTERFACED WITH FAP: CONTRACTOR IS TO COORDINATE WITH WAREHOUSE FIRE ALARM SERVICE COMPANY. FIRE ALARM SERVICE COMPANY INVOICE(S) TO BE PAID BY WAREHOUSE. 4. CONTRACTOR IS TO BE PRESENT DURING TEST WITH FIRE ALARM SERVICE COMPANY TO DEMONSTRATE FUNCTIONAUTY, 5. CONTRACTOR IS TO BE PRESENT DURING ANY TEST(S) REQUIRED BY JURISDICTION. 6. PER 2015 IMC: 606.2: SMOKE DETECTORS SHALL NOT BE REQUIRED WHERE AIR DISTRIBUTION SYSTEMS ARE INCAPABLE OF SPREADING SMOKE BEYOND THE ENCLOSING WALLS, FLOORS AND CEILINGS OF THE ROOM OR SPACE IN WHICH THE SMOKE IS GENERATED. 1/2" GAS (150 MBH)\ 0 1" GAS (345 MBH) r- L DIFFUSER TO BE MOUNTED AS CLOSE TO COLUMN AS POSSIBLE. 1" GAS (540 MBH) 3/4"--.',AS (195 NW DIFFUSER TO BE MOUNTED AS CLOSE TO COLUMN AS POSSIBLE. PROVIDE ROOF SUPPORT/C La PIPING LOCATED ON ROOF. PROVb INTEG9A1 E 6 . . I INSTRNISTRUT PROVIDE SUPPORT AT MINIMUM INTERVAL FOR ALL NEW PIPING 1-1/4" (930 MB SEE DETAIL (TYP OF 5) UNIT CENTER OF GRAVITY OF TO BE ABOVE GLULAM BEAM AT COLUMN. EXISTING POWER VENTILATOR TO BE REMOVED ROOF OPENING TO BE CAPPED. ON ROOF. FOR HVAC WORK IN THI AREA, SEE "REGISTER HVAC PLAN" ON SHEET M-2. 00000 000000 E DETAIL UNIT CENTER OF GRAVITY OF TO BE i ABOVE GLULAM BEAM 01 OLUMN. SEE DETAIL EXISTING POWER VENTILATOR TO BE REMOVED ROOF OPENING TO BE CAPPED. SEE DETAIL PRIOR TO INSTALLATION 1. VERIFY EXISTING DUCT DROPS ARE FREE AND CLEAR OF SPRINKLER PIPING, STRUCTURAL MEMBERS. ETC. 2. PROVIDE DIMENSIONAL DATA TO COIL TECH FOR EACH DUCT DROP. FOR FABRICATION ALLOW 4 WEEK LEAD TIME FOR FABRICATION AND SHIPPING. 3. DIFFUSER REPLACEMENT OPTION. IF INTERFERENCE OR OTHER CIRCUMSTANCES PROHIBIT EASY REPLACEMENT OF THE ENTIRE DUCT PACKAGE PROVIDE EXISTING DUCT SIZE INFO FOR ATTACHMENT OF NEW DIFFUSER TO EXISTING SUPPLY DUCT. 4. VERIFY EXISTING UNIT NUMBER AND MODEL IN SCHEDULE. 5. VERIFY ANY STRUCTURAL PLANS MATCH MECHANICAL PLANS. EXISTING POWER VENTILATOR TO BE REMOVED ROOF OPENING TO BE CAPPED. i 1_ SEE DETAIL FOR HVAC WORK IN THIS AREA, SEE "RECEIVING HVAC PLAN" ON SHEET M-2. EXISTING GRAVITY FVENTRATORING 0 BE REMOVED ROOF OPENING TO PV BE CAPPED. REMOVE EXISTING HIGH INTENSITY RADIANT HEATERS I RECEIVING, SET ASIDE FOR REUSE/RELOCATION EXISTING GRAVITY VENTILATOR TO BE REMOVED ROOF OPENING TO BE CAPPED. MAIN MECHANICAL PLAN SEE DET SCALE: 1/16" 1'-0" 11) EXISTING POWER VEND TO BE REMOVED ROOF OPENING TO BE CAPPI 00000 20 0 HVAC HEAT PUMPS M -1 let I SEPARATE PERMIT ijijijiI R UIRED FOR: Mech/nzW ec6 ctl Plumbing ❑ Gas Piping City ofT kvnla BUILDING DIVISION REVIEWED FOR - CODE COMPLIANCE 11 APPROVED NOV 257019 1- Pcd 0-- City of Tukwila BUILDING DIVISION CORRECTION S1E EIVED CITY OF TUKW'ILA NOV 19 2019 PERMIT CENTER PUMPS\_276M-2.dwg, 10/8/2 ROOF,. 24/24 SCREEN OPENING AT FACE OF WALL 36/24 DN FROM MEZZANINE TO ABOVE TOP OF COOLER. „WET AIR DOOR REMOVE EXISTING 8FT AIR DOOR AT ENTRANCE DOORS TO RETURNS DQQOR OPENING. INSTALL NEW 1QFT AIR DOOR AT ENTRANCE LOOKS. MOUNT W10'A.F.F. SET DIFFUSER FLUSH WITH FACE OF COOLER/WALL 111.6*w="1111. CIE' Vall.�IYEIYi�wzrrn��.�.�w>_ .._ .., LLLI II 24/24 R TYP OF 4) 24/24 RA DUCT ON TO CEILING 24/24 RA DUCT UP TO 80TTOM OF TRUSSES OX20 DL 1125 CFM EACH (TYP OF 7) REAR WAREHOUSE HVAC PLAN SCALE: 1/16" = 1'-0" SEE SCHEDULE FOR - SUCTION UNE AND LIQUID LINE SIZES FROM CONDENSING UNIT TO AIR HANDLER TRANSITION SA DUCT TO INDOOR UNIT SUPPLY AIR CONNECTION. SEE PLAN FOR CONTINUATION OF SUPPLY DUCT. PROVIDE PAN BELOW INDOOR UNIT WITH DRAIN TO EDGE OF PHARMACY ABOVE CONCRETE. SEE PLAN FOR CONTINUATION OF RETURN DUCT. SPLIT SYSTEM ELEVATION DETAIL CE SCALE: NONE NOTE COORDINATE LOCATION OF RADIANT HEATER W/LIGHTS. HEATER SHALL BE INSTALLED MEETING ALL CLEARANCE REQUIREMENTS RECOMMENDED BY THE MANUFACTURER. INSTALL RH W AN ANGLE 29' FROM HORIZONTAL TOWARD DIRECTION INDICATED. GAS MAIN AND ELECTRICAL LINES MUST NOT CROSS OVER TOP OF HEATER. GAS MANIFOLD MUST BE LOCATED ON LOW SIDE OF HEATER. GAS MAIN & SUPPLY TO RH SIZED PER PLAN DRIP LEG GAS COCK SUPPLIED BY M.C. PROVIDE CAPPED TESTING TEE. TEE TO BE LOCATED WHEN GAS PRESSURE EXCEEDS MINIMUM DISTANCE OF 10 14" W.C. A FIRST STAGE PIPE DIAMETERS FROM PRV REGULATOR MUST BE INSTALLED INTAKE AND OUTLET BY M.C. RADIANT HEATER DETAIL SCALE: NONE "S"1 HOOK 3/1" CHAIN 1 REFLECTOR TUBE/REFLECTOR HANGER CANOPY ROOF NOTE: VERIFY MINIMUM CLEARANCE TO COMBUSTIBLES. G) FRO0 M 08 88AIRENTRANCDOOR, E DOOR0008 -"-�) R LOWER EXISTING LOFT AIR DOOR AT EXIT DOORS TO BE 10FT A.F.F. ToI U RELOCATE (5)EXISTING RADIANT HEATERS] FROM RECEIVING AREA. FIELD VERIFY LOCATION Fi REGISTER HVAC PLAN SCALE: 1/16" = 1'-0" 1/0 TENSO CHAIN MOUNTED SUPPORTS TO ROOF STRUCTURE (TYP. OF 2 FOR EACH HEATER) PROVIDE HEAT SHIELD FOR HEATERS UNDER 100 MBH HOOKS; 1/4" DIA. WIRE (CRIMP ALL 'S' HOOKS CLOSED) OUNTING ANGLE, SEE SCHEDULE 13' A.F.F. FOR ALL RH SIZE K-30 (MEMBERSHIP, REC. COUNTER) 4" TYPE "B" VENT CAP 4" TYPE "8" VENT PIPE NON -HARDENING CAULK BEAM CLAMP CANOPY ROOF" -BIRD NETTING _.. 7 DECK TITS OBTAINED FROM MBS CEILING CLOSURE-' PLATE 4" SINGLE WALL PIPE_""I \-S.S. WIRE MESH BY NETTING I CONTRACTOR BURNER TUBE NT ADAPTER REFLECTOR VENTING CANOPY INFRARED HEATER DETAIL SCALE: NONE IN. CANOPY_/ TIRE INSTALL ROOF SEE DETAIL 0 MOUNT FAN ON L-J2,Y,iN9.100TRB DN TO _10E-f ABOVE MEZZ FLOOR SEE DETAIL SECURE CONDENSIryry IT TO MEZZANINE STRNCTURE. PROVIDE AIBRATIONI 150421TION MECHANICAL MEZZANINE VENTILATION PLAN SCALE: 1/18" = 1'-0" GAS TO RH. SIZE PER PLAN. VENT TO OUTSIDE ill BURNER PROVIDE CAPPED TESTING TEE MINIMUM 10 PIPE DIAMETERS AWAY FROM PRV INTAKE AND OUTLET. 28 RADIANT HEATER GAS PIPING SCALE: NONE D IP LEG FIXTURE DRAIN PER PLAN CONDENSATE 3/4" NOTE: CONNECTION TO BE APPROVED BY LOCAL PLUMBING INSPECTOR PRIOR TO INSTALLATION REMOVE (6)EXISTING HIGH INTENSITY RADIANT HEATERS. SET ASIDE FOR REUSE WITHIN THE 18 IILDING. DEMO EXISTING GAS PIPING TO EXISTING HIGH INTENSITY RADIANT HEATERS AND EXTEND 3/4" GAS AT 2 PSI TO NEW TUBE HEATER FIELD VERIFY SIZE AND PRESSURE OF TING GAS LINE. 1 /4 RUN 3/4" CONDENSATE 17.1 I_1 ,.. �1 3/4" GA (350 MBH) G - SEE DETAIL \ UNIT MOUNTED HIGH ON WALL /2" GAS ILA (80 MBH) LOCATE RADIANT HEATERS 5FT FROM WALL, AVOID LIGHTS AND SPRINKLER PIPING (TYP OF 4) /2" GAS 1 (270 MBH) 1/2" GAS (160 MBH) SEE DETAIL 1/2" GAS 80 MBH) (TYP OF 4) /2" GAS (110 MBH) /2" ]GAS (30 MEH) RELOCATE (1)30MBH HIGH INTENSITY RADIANT HEATER TO FUTURE RN LOCATION. VERIFY LOCATION WITH BUILDING MAN4OEMENT. SEE DETAIL RECEIVING AND BREAK ROOM HVAC PLAN SCALE: 1/16" = 1'-0" TRAP & ARM SIZE PER SCHEDULE CONDENSATE CONNECTION TO DRAIN 73 SCALE : NONE 4"X6" TREATED W00D SLEEPERS FASTENED TO ROOF DECK SPLIT SYSTEM AC OUTDOOR UNIT MOUNTED TO SLEEPERS. BUILT-UP ROOT PROVIDE DECKTITE FOR SUPPLY & RETURN REFRIGERANT LINES. REFRIGERANT GAS SUCTION RETURN LINE REFRIGERANT LIQUID SUPPLY LINE OFFICE LIGHTS LIGHTS SPLIT ST]IEM AC INDOOR UNIT MOUNTED ON WALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS. CONDENSATE FOR INDOOR UNIT TO CONDENSATE DRAIN. F LOOR OFFICE SPLIT SYSTEM AC UNIT DETAIL 74 SCALE: NONE UMPS\_276M-3.dwg, 10/8/2019 of SYMBOL AC 4 AC-7,8 9,10,11 AC-12 CU 13 AH-13 CU-15 CLCL-1542.0 ITEM AIR CONDITIONER __ ( AIR CONDITIONER AIR CONDTTONER • II AIR CONDITIONER AIR 1 CONDITIONER -; AIR CONDTIIONER' COOLING COIL SERVES TIRE SALES - -- MAIN SALES{PAON MAIN SALES LOW HEAT -"'_"--'--+ I SALES I MFR/ AAON RO-004-3 CA81-212 RN-015-3 E60S-2F2 TRANE YH0300G4 RXA--KA _ f TRANS j TWA240440I HVAC EQUIPMENT SCHEDULE-S.O,I,C. ELECT. WEIGHT REFERENCE( NOTES STRUCTURAL VERIFICATION MFR/M EXISTING UNIT DATA NET WEIGHTS (DESCRIPTION REMARKS HEAT ELECTRICAL NEW NET WEIGHTS REMARKS 48 MBH TOTAL COOLING. 34 MBH SENSIBLE, 81.6 AMB, 78.6 EDB, 65.6 EWB, 1600 CFM 0 0.5" ESP, SEER = 15.7, 80 MBH INPUT, 48.6MBH OUTPUT, 81% AFUE 460V/30 15 MCOP 13.2 FLA ;PLAN M-1 60/M 450 CFM MIN 0/A ((1) (55 57 (64) )( ) TRANS YCD048C4 LGAA NATURAL GAS 80 MBH 460V 30 75 MCOP 11.9 MCA 879 #:(E)UNIT 82 #:(E)CURB 470 (E DIFF ) 1 1390 #:NEW TOTAL 1998 #:NEW UNIT 300 /:CURB 507 #:NEW DIFFUSER NEW UNIT WEIGHTS 2769# MORE THAN EXISTING CONDITION', 275 MBH TOTAL COOUNG, 237 MBH SENSIBLE, 100.8 AMB, 82. EDB, 66. EWB, 9600 CFM 0 0.5" ESP. EER = 10.6, _2_50 MBH INPUT, 200MBH OUTPUT, 80% AFUE PLAN ME-1 2/ME _ (PLAN ME-1 171/ ME 1,356 CFM MIN 0/A SUPPLY FAN FEG >_ 67 (6) (56) (60)(64) 74 ( ) TRANS YC0301C4 LGPA NATURAL GAS 250 MBH 460V/30 70 MCOP 56 MCA 3100 #:(E)DESIGN 2769 jiNEW TOTAL. '2703I .NEW UNIT 300 #:(E)CURB /�( 329 /:(EEjjDIFF NEW UNIT WEIGHTS 191# MORE THAN EXISTING CONDITION 1 234 MBH TOTAL COOLING, 74.3 AMB, 79.0 EDB, 65.0 EWB, . 0 0.5" ESP. EER = 11.2, L HEATING: 285MBH .....___. 1-1/8" SUCTION UNE 1/2" UQUIO UNE (59) f :NEW TOTAL 8<'S/:NEW TOTAL NEW UNIT WEIGHS 8458 MORE THAN EXISTING CONDITION SALES . TRANE ! COIL CONNECTED TO CU-13 7WE240448 1 8000 CFM 460V/30 5 HP 15 MCOP 8 MCA 400V/30 49 MCOP 49 MCA 43.8 RA 1PIAN ME-1 170 ME i / _.._ _ (72) - ,818 N EW UNIT I NEW UNIT MOUNTED INSIDE -- .--..--. MAIN SALES SAE SALES CONDENSING UNIT 25 NOMINAL TONS TRANS 15/8" LIQUID TTA3pp44 136.0 LIQUID LING GAS CAB ' 42.0 MBH COOLING SEER 15.6 MBH HEATING _..._.. U7 TNSTALLEU- PI IONS: YVALV06A - SERVICE VALVE YGARD0 1 A - HAIL GUARD BAYBCIR001A - BHOT G BAYHL -HOT GAS BYPAS --- ---- - 1000#:NEW UNIT 240#: NEW LINO TRANE 1078480]2 KA7 DUCT MOUNTED C-/8 COIL, 14,000CFM 48"H%72"W 1-1/8" UQUiD 1-5/8" GAS 358MBH TOTAL MOUNTED COIL MOUNTED IN INTAKE DUCT OF EXISTING GHU 14 AC-17 AIR CONDITIONER REARS AA 010-3 C801-222 109 AMB, TOTAL CUBING 65.178 EWB,H SENSIBLE, 0 0.5" ESP, EER = 11.7, 90 MBH INPUT, 72.9MBH OUTPUT, 81X AFUE 40 6008 28 MCA PLAN M-1 60/M 300 CFM MIN 0/A (5j (55)(57) (64) TRANS YCDO60C4 LGAA NATURAL GAS 90 MBH 460V/30 20 MCOP 18.3 MCA 700 #:(E)UNIT 82 #:(E)CURB 250 #:(E)DIFF 1032 #:(E)TOTAL 82 ))CURB NI NEW UNIT WEIGHTS 200# :AbPPTER 793# MORE THAN 275 :NEW DIFFUSER EXISTING CONDITION 1825 /:NEW TOTAL CU-32 '',, AIR CONDTIONER BREAK TRANS RO0M PUZ-A36 OUTDOOR HEAT PUMP UNIT 3 NOMINAL TONS 1-3/8" GAS, 5/8" 000ID, 208V/10 30 MCOP - PLAN ME-1 (64) 214#:NEW UNIT NEW UNIT WEIGHS NKA7 36.0 MBH COOING SEER = 15.8 42.0 MBH HEATING 25 MCA 75/ME 214N MORE THAN EXISTING CONDITION ' AH-32 AIR CONDITIONER ( BREAK TRANS ROOM I PKA-A36 KA7 INDOOR WALL MOUNTED AIR HANDLER 705-920 CFM 3/8" LIQUID 5/8" GAS 38.0 MBH COOLING & HEATING 208V/10 1 MCA PLAN ME-1' 75/ME UNIT MOUNTED ON WALL (72) 46#:NEW UNIT NEW UNIT MOUNTED INSIDE AH POWERED FROM CU i GENERAL NOTES - All equipment furnished by costco, installed by m.o. contact costao purchasing dept. to coordinate delivery time 0 email: 1perry000590o.com - AC units provided with DD.C. communications interface controlled by building management system by controls installer. sensor/t'stat 5.1.0. sensors 0 +72", t'stata at 48" A.F.F. - Contractor to install all items listed in equipment submittal per manufacturers installation and operation manual - Roof curbs provided by M.B.S. unless otherwise noted - Gloss I motorized OSA damper with 3 cfm/sf 0 1" wg leakage rate and class I motorized return air damper with 4 efm/sf 0 1" wg leakage rate integral to all AC units. - Thermostatic controls configured with 5'F minimum deadband for systems that control both heating and cooling. - Systems to be configured to provide not more than 150% of, but at least the minimum required volume of outdoor air to each zone per IMC. - Economizers to provide up to 100% OSA for cooling. Provide with high limit shutoff control per Table C403.3.3.3. (1) *INTEGRATED ECONOMIZER WITH DDC ACTUATOR •115V CONVENIENCE OUTLET - FACTORY WIRED *POWER SWITCH 100 AMPS *2" PLEATED 30% EFFICIENT FILTERS *PHASE & BROWN OUT PROTECTION *FACTORY INSTALLED DDC CONTROLS FURNISHED BY OTHERS + ISOLATION RELAYS (SPA REQUIRED) (2) *SUPPLY WITH FACTORY INSTALLED RETURN AIR BYPASS *INTEGRATED ECONOMIZER WITH DOC ACTUATOR *115V CONVENIENCE OUTLET - FACTORY WIRED *POWER SWITCH 100 AMPS *2" PLEATED 30% EFFICIENT FILTERS *PHASE & BROWN OUT PROTECTION *FACTORY INSTALLED DOC CONTROLS FURNISHED BY OTHERS + ISOLATION RELAYS (SPA REQUIRED) (5) *INTEGRATED ECONOMIZER WITH DDC ACTUATOR •115V CONVENIENCE OUTLET - FACTORY WIRED *POWER SWITCH 100 AMPS *2" PLEATED 30% EFFICIENT FILTERS *PHASE & BROWN OUT PROTECTION *FACTORY INSTALLED DDC CONTROLS FURNISHED BY OTHERS + ISOLATION RELAYS (SPA REQUIRED) (6) *RELIATEL *HINGED PANELS/2" MERV 8 FILTERS *STANDARD CONDENSER COIL W/HAIL GUARD *THROUGH THE BASE GAS & ELECTRICAL *POWERED CONVENIENCE OUTLET *UNIT MOUNTED CIRCUIT BREAKER • LOW LEAK INTEGRATED ECONOMIZER W/FAULT DETECTION/01AG, •BACNET COMMUNICATIONS INTERFACE *FAN FAILURE SWITCH AND DISCHARGE AIR SENSING TUBE *SINGLE ZONE VAV (WO) STANDARD SHAFT GROUND *STAINLESS STEEL HEAT EXCHANGER (55) HVAC SUPPLY & RETURN DUCT DROP S.O.I.C. (56) REUSE EXISTING CURB (57) ADAPTER CURB BY G.C. TO INCLUDE SEISMIC AND WIND LOAD CALCULATIONS. (59) NEW CURB BY GC (60) OUTSIDE AIR CONTROLLED BY FIELD INSTALLED CO2 SENSOR TO MAINTAIN MAXIMUM 1,000 PPM CO2 AND MAINTAIN THE BUILDING AT A POSITIVE STATIC PRESSURE (63) **PER CBC CHAPTER 34 SECTION 3404.3: IF GRAVITY LOAD INCREASE IS LESS THAN 5%, NO STRUCTURAL MODIFICATION IS REQUIRED (64) SEE STRUCTURAL PLANS FOR ANY REQUIRED MODIFICATIONS FOR INCREASED WEIGHT (65) CENTER OF GRAVITY OF UNIT TO BE DIRECLTY OVER GLULAM AT COLUMN (72) TO 8E SUPPLIED WITH PROGRAMMABLE ELECTRONIC NIGHT SET -BACK THERMOSTAT (74) UNIT TO 8E INSTALLED WITHOUT HAIL GUARDS EXISTING HVAC EQUIPMENT SCHEDULE SYMBOL ITEM SERVES MFR/# DESCRIPTION ELECT. WEIGHT REFERENCE REMARKS NOTES AC-1 (EXISTING). AIR CONDITIONER PHARMACY TRANS YHC036E4 RLA 36.7 MBH TOTAL CODING, 27.9 MBH SENSIBLE, 1200 CFM 60 MBH INPUT, 48MBH OUTPUT, 80% AFUE 460V/30 15MCOP 8.8FU 720# EXISTING UNIT TO REMAIN AC-2 (EXISTING) AIR CONDITIONER 0FflCE TRANS WSC048E4 ROA 48.9 MBH TOTAL COOUNG, 33.9 MBH SENSIBLE, 44.4 MBH TOTAL HEATING, COP = 3.4 1600 CFM 460V/30 15MCOP 10.6FLA 653# EXISTING UNIT TO REMAIN AC-3 (EXISTING} AIR CONDITIONER FOOD SERVICE TRANS RMOAl2 118.4 MBH TOTAL COOLING, 107,8 MBH SENSIBLE, 200.0 MBH INPUT, 162.0MBH OUTPUT, 48 % AFUE 460V/30 I 2300# 22.8 MFLAP I , EXISTING UNIT TO REMAIN AC-5 (EXISTING) ATR CONDITIONER Optical TRANS 4YCC4024A 1060A 24 MBH TOTAL COOUNG, 21 MBH SENSIBLE, 800 CFM 60 MBH INPUT, 48.6MBH OUTPUT, 81% AFUE 208V/10 388 #:((E)UNIT 30 MCOP 135#: ESCURB 19.1 MCA 350 E DUCT =73 :ETOTA EXISTING UNIT TO REMAIN GHU-14 (EXISTING) GAS HEATING UNIT MAIN SALES TRANS DF0A218FN HE1AGK03A DIRECT FIRED GAS HEATING UNIT 1650 MBH INPUT, 1518 MBH OUTPUT, 100% AFUE 460V/30 15 HP 1300':UNI 200#CURB 800#DIFF 2300#:T0TAL EXISTING UNIT TO REMAIN AC-16 AIR CONDITIONER BOTTLE ASSEMBLY TRANS YC0048C4 LGA4 48.9 MBH TOTAL COOUNG, 35,7MBH SENSIBLE, 85' 460V/30 11.9 MCA 850# EXISTING UNIT TO REMAIN AC-18 AIR CONDITIONER POPCORN RM WARM ZONE TRANS YC0090C4 92 MBH TOTAL COOLING, 67,7 MBH SENSIBLE, 85' 460V/30 r 1100# 20.9 MCA EXISTING UNIT TO REMAIN AC-19 AIR CONDITIONER NEW SUPPLY TRANS YCO240A4 (EXISTING) 460V/30 j EXISTING UNIT TO REMAIN AC-20 AIR CONDITIONER BREAK ROOM UPPER LEVEL TRANS Y00030F1 M08A 29.8 MBH TOTAL COOUNG, 21.5 MBH SENSIBLE, 85' 10.00, 60 MBH INPUT, 48 MBH OUTPUT, 78% ANE. 208V/10 450# 13.2 MCA EXISTING UNIT TO REMAIN AC-21 OU-22 U-22 AIR CONDITIONER OFFICE TRANS YCD036C4 IGAA 3/.4 M*H TOTAL COOLING, 27.3 MBH AMB, 80 EDB, 67' EWB, 1200 CFM 0 .5" ESP. SEER= 10.00, 80 MBH INPUT, 62 MBH OUTPUT, 78% AFUE. 460V/30 450# 9.4 MCA EXISTING UNIT TO REMAIN AIR CONDITIONER AIR CONDITIONER FOOD SERVICE TRANS 4TXK8536A1 3 TON P1R COOLED CONDENSING UNIT, HEAT PUMP 208V/10 35 MCOP 23 MCA 161 #:UNIT EXISTING UNIT TO REMAIN S000 SERVICE TRANS 4MXW8536A1 12.8 MBH TOTAL COOUNG, 1200 CFM INDOOR UNIT POWERED FROM OUTDOOR UNIT 44 #:UNIT EXISTING UNIT TO REMAIN PLUMBING LEGEND C- CONDENSATE DRAIN G - GAS • GAS COCK DC VALVE - GATE Xp I VALVE - BALL P�IU VALVE - PRESSURE REDUCING A.F.F. ABOVE FINISH FLOOR AHJ AUTHORITY HAVING JURISDICTION CO CLEAN OUT CONT. CONTINUATION G.0 GENERAL CONTRACTOR IN. WC INCHES OF WATER COLUMN MBH 1,000 BRITISH THERMAL UNITS/MR M.C. MECHANICAL CONTRACTOR PSI POUNDS PER SQUARE INCH TYP. TYPICAL LINO UNLESS NOTED OTHERWISE HVAC LEGEND 24/48 k 5 k IV AIR DUCT - FIRST # IS SIDE SHOWN FLEXIBLE DUCT CONNECTION SUPPLY DUCT UP RETURN DUCT UP AIR VOLUME DAMPER CEILING DIFFUSER SQUARE TO ROUND DUCT TRANSITION -C- CONDENSATE DRAIN AIR CONDITIONER #1 QT THERMOSTAT Q THERMOSTAT (W/LOCKING COVER) 05 SENSOR CONT. CONTINUATION TYP. TYPICAL GEM CUBIC FEET PER MINUTE D8 DRY BULB TEMPERATURE NB wET MILD TEMPERATURE MBH 1,000 EIRMSH THERMAL UNITS/HR. ESP EXTERNAL STATIC PRESSURE EG EXHAUST GRILLE RG RETURN GRILLE CD CEILING DIFFUSER RA RETURN AIR SA SUPPLY AIR VD VOLUME DAMPER M85 METAL BUILDING SUPPUER M.0 MECHANICAL CONTRACTOR G.0 GENERAL CONTRACTOR SYMBOL EF-31,32 ITEM EXHAUST FAN EQUIPMENT SCHEDULE - S.I.C. EXHAUST FAN SERVES MECHANICAL RM. MFR/# COOK ACRU-B 225SCH8B DESCRIPTION 5,340 CFM 0 0.50" SP. CONTROLLED BY T'STAT PROVIDED BY G.C., WIRED BY E.C. PROVIDE WITH AUTOMATIC BELT TENSIONER. ELECT. 1.5 HP 208V/30 WEIGHT 3000 REFERENCE 15/M REMARKS 26" S0. ROOF OPENING. NOTES (1) (2) GFNFRAI NOTF0: (APPLIES TO ENTIRE SCHEDULE AS APPLICABLE) 1. ALL SWITCHES AND T-STATS MOUNTED AT 42" AFF UNLESS OTHERWISE NOTED SEE DESCRIPTION FOR RESPONSIBLE CONTRACTOR. 2. DO NOT ADJUST SPEED CONTROLLER SLOWER 60% OF FAN MOTOR SPEED. 3. PROVIDE MOTOR STARTER AND OVERLOAD PROTECTION FOR ALL MOTORS PER SPEC SECTION 230000. RC.HF0111 F NOTES: (SEE COLUMN ON RIGHT FOR APPLICABILITY): (1) ROOF/ADAPTER CURB BY G.C. (2) PROVIDE BACKDRAFT DAMPER. (3) ALLOW UP TO 200% OF AIR FLOW FOR BALANCE. (4) PROVIDE FAN SPEED CONTROLLER MOUNTED IN ACCESSIBLE LOCATION NEAR EQUIPMENT (U.N.0.). (5) PROVIDE WITH INLET SAFETY SCREEN. SERVES AIR j FRONT DOOR '�, ENTRANCE AIR DOOR EQUIPMENT SCHEDULE MFR/# 'DESCRIPTION I ELECT. I WEIGHT POWERED AIRE ELECTRIC HEATED AXIAL FAN UNIT HEATER, FRONT �(3) 3/4 HP 84# ETD-3-120E INTAKE. 10' LONG, 3174/2134 AVG FPM, 7614/5127 CFM �IMOTORS 30 REMO1E HEAT ON/OFF & T'', 63 DBA. COMES STAT. MOUNT SWTH REMOTE ITTCHES I9V/4 .7 042" A.F.F. OWNER PROVIDED, INSTALLED M.C, MCOP 60 REFERENCE REMARKS PUN M-1. NOTES SEE SPECIFICATIONS; SINGLE ELECTRICAL CONNECTION. ALL ELECTRICAL BY E.C. (1) AIR DOOR RETURNS DOOR EXISTING) AIR DOOR FRONT ENTRANCE (EXISTING) IWERED AIRE D-2-96E POWERED AIRE ETD-3-120E ELECTRIC FAN NTAKE.8 HEATED 0 0, UNIT HEATER, FRONT FPM, 7614/5127( CFM MOTORS4 HP 20 KW, 84 PLAN M-1.1 EXISTING ELECTRICAL SERVICE (3) TO BE EXTENDED FROM EXISTING LOCATION ELECTRIC HEATED AXWL FAN UNIT HEATER, FRONT '(3) 3/4 HP I284# INTAKE. 10' LONG. 3174/2134 AVG FPM, 7614/5127 CFMRJOTORS I 480V/30 FLA 42.7 MCOP 60 PLAN M-2 EXISTING ELECTRICAL SERVICE TO BE REUSED (3 Q1 S.0,I.C. QZ EXISTING UNIT 03 EXISTING UNR TO BE RELOCATED AIR TERMINAL SCHEDULE SYMBOL RG DL MANUFACTURER TUTTLE & BAILEY TUTTLE & BAILEY SERVICE RETURN SUPPLY PR STRJ MODEL PATTERN PERFORATED DRUM LOUVER DAMPER NECK FRAME LAPIN FLANGE LOCATION • OFFICES, OPTICAL SALES FLOOR * VERIFY NUMBER OF DIFFUSERS AND ALL LOCATIONS ON PLANS - DIFFUSER IS NOT REQUIRED IF NOT ON PLANS •* DIFFUSER TO HAVE BRUSHED STAINLESS STEEL FACE. DO NOT PROVIDE WITH FILTER, INFRARED HEAT EQUIPMENT SCHEDULE - S.I.C. SYMBOL ITEM SERVES MFR/# DESCRIPTION ELECT, WEIGHT REFERENCE REMARKS NOTES RH-1,2 INFRARED HEATER PHOTO RG - TWO STAGE INFRARED TUBE HEATER, 80 MBH INPUT, 120V/10 VANTAGE 20' LENGTH ALUMINIZED TUBE W/STANDARD 7.3 FLA CTH2-80 ALUMINUM REFLECTOR. CONTROLLED 8Y YSTAT. MOUNT EMITTER TUBE 0 17' A.F.F. 201# PLAN M-1 28/M T'STAT W/LOCKING COVER PROVIDED & INSTALLED BY M.C. RH-3-6 INFRARED HEATER RECEIVING RG TWO STAGE INFRARED TUBE HEATER, 80 MBH INPUT, I VANTAGE 20' LENGTH ALUMINIZED TUBE W/STANDARD CTH2-80 ALUMINUM REFLECTOR. CONTROLLED BY YSTAT. MOUNT EMITTER TUBE 0 17' A.F.F. 120V/10 ,1,3 FLA 201# PUN M-7 28/M T'STAT W/LOCKING COVER PROVIDED & INSTALLED BY M.C. RH-RELO' GENERAL - EQUIPMENT - M.C. - T'STAT INFRARED HEATER NOTES. TO BE TO PROVIDE TO BE MOUNTED REGISTERS EXISTING HIGH INTENSITY RADIANT HEATERS RELOCATED FROM RECEIVING AREA. 30MBH 120V/10 1.3 FLA 126# PLAN M-1 28/M T'STAT W LOCKING COVER I PROVIDED & INSTALLED BY M.C. --- PROVIDED AND INSTALLED BY M.C. CONTROL WIRE AND CONDUIT FOR T'STAT 0 78"A.F.F. UNLESS NOTED OTHERWISE GENERAL MECHANICAL NOTES THE NuawNa Auks ro ENIttvE Ww As ,4 Il,nrar 1. M.C. SHALL ENSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLAN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES HVAC UNITS & EXHAUST FANS. LABELS SHOULD BE IN 6" BLOCK LETTERING IN BLACK COLOR AND LOCATED WHERE EASILY VISIBLE FROM THE ROOF HATCH. 2, MAINTAIN A MINIMUM OF 10-0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. 3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OR PANELS. 4. DIMENSIONS ARE TO COLUMN LINES. 5. APPLICABLE BUILDING CODE 2015 IBC APPUCABLE MECHANICAL CODE: 2015 IMC APPLICABLE ENERGY CODE: 2015 IECC 7. PROVIDE TIE DOWN FOR ALL NEW FLUES & VENTS OF 3' OR TALLER. 8. RUN ALL SUPPLY, RETURN AND EXHAUST DUCTS AND FLUES BETWEEN THE ROOF AND CEILING SPACE STRAIGHT WITH INTERNAL INSULATION. NO ANGLES OR OFFSETS. CONTACT ARCHITECT TO RESOLVE ANY CONFLICTS WITH STRUCTURE. 9. ALL CONDENSATE PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. 10. RUN PIPING IN ROOF TRUSS SPACE PERPENDICULAR OR PARALLEL TO BUILDING JOIST OR GIRDERS, FOR PASSING BELOW SOUD GIRDERS MOUNT PIPING 8" MAXIMUM, FROM BOTTOM OF GIRDER. 00 NOT BLOCK LIGHTING & SKYLIGHTS. 11. ALL DUCTWORK IS CONSTRUCTED AND SEALED PER 2015 IMC. ALL OSA DUCTWORK TO MEET THE AIR LEAKAGE REQUIREMENTS OF SECTION C402.5 AND VAPOR RETARDER REQUIREMENTS OF THE IBC. 12. ALL DUCTWORK IS LOW PRESSURE. 13. COMMISSIONING IS REQUIRE➢ PER C408 FOR ALL APPLICABLE MECHANICAL SYSTEMS. AIR FLOW RATES SHALL BE TESTED AND BALANCED WITHIN THE TOLERANCES DEFINED IN THE SPECIFICATIONS; SYSTEMS SHALL BE BALANCED TO FIRST MINIMIZE THROTTLING LOSSES, THEN ADJUSTED TO MEET DESIGN FLOW CONDITIONS. SSUED FOR PER HVAC SCHEDULE, LEGEND AND DETAILS 0 HVAC HEAT PUMPS M-3 ` ?Gfto79 REVIEWED FOR CODE COMPLIANCE • APPROVED NOV 252019 City of Tukwila BUILDING DIVISION C11' OF TUKW .0 NOV 1 9 2019 +''t-RT31T CENTER NOTE: 1) ALL PVC ON EXTERIOR.; OF BUILDING TO BE SCHEDULE 80. 2) PAINT ALL METAL & PVC PIPING EXPOSED TO WEATHER. OUTLETS ^HA .'..... FROM ""1AC UNIT_ '........,1�.._. AC CONDENSATE PIPING DIAGRAM SUPPLY SIDE VIEW TERMINATE VENT BELOW CONDENSATE OUTLET FROM AC UNIT 1-1/2" MIN -1/2" MIN SCALE NONE VENT CAP PRV GAS TO AC UNIT REDUCE TO 3/4" GAS SHUT OFF PROVIDED BY GAS PIPING ASSEMBLY SIZE BELOW ROOF PER PLAN ABOVE ROOF GAS PIPING TO BE PAINTED SAFETY YELLOW CLOSE ISOLATION VALVE. REMOVE PIPING AS REQUIRED FOR REMOVAL OF UNIT. RE -PIPE THROUGH THE BASE WITH EXTERNAL ISOLATION VALVE FIELD VIERFY ISOLATION VALVE BETWEEN ROOF PENETRATION AND GAS MAIN. INSTALL NEW VALVE AS REQUIRED TO ISOLATE AND REPLACE UNIT. Op5 DRIP LEG ROOF TOP AC UNIT Eq AV'— SPACED ROOF DECK I .11_ ROOF TOP AC UNIT DO NOT BLOCK ACCESS PANELS NEOPRENE GASKET BY M.C. RIGID INSULATION ROOF DECK SEE STRUCTURAL FOR HOLD DOWN CONFIGURATION: NUMBER AND LOCATION. HOLD DOWN CABLE TO BE INSTALLED WITHIN 5' OF VERTICAL. 3305318 1/8" PREFORMED SS CLEVIS AIRCRAFT CABLE 5" #12 SELF DRILLING SCREW, HOLD DOWN CABLE SUPPLIED BY OWNER, INSTALLED BY M.C. INSTALL IN CORRECT 2 ORIENTATION SO EYELET IS FLUSH WITH SURFACE. -71------#12 SELF DRILLING SCREW W/NEOPRENE WASHERS. 14 GA. ROOF CURB. SEE SCHEDULE FOR PROVIDER AC UNIT HOLD DOWN CABLE SCALE: NONE CURB TO BE MANUFACTUERED WITH SUPPLY OFFSET TO ALLOW UNIT CENTER OF GRAVITY TO BE LOCATED ABOVE COLUMN. LOCATE CENTER OF GRAVITY OF UNIT ABOVE COLUMN AC THRU THE BASE GAS FrPING DIAGRAM 0 SPECIAL ORDER CURB DETAIL SCALE: NONE SCALE: NONE PUMPS\_276M-4.dwg, 10/8/2019 wiio 4006) — WA K:A2018\270 DUCT CONNECTOR DRUM LOUVER SHIPPED LOOSE, INSTALLED BY M.C. (TYP. OF 4) STANDARD SUPPLY DUCT DROP 1" CURB FLANGE LOUVER SHIPPED LOOSE, INSTALLED BY M.C. (TYP. OF 2) / OW PROFIT F NOTE: TRIM DUCT AS 8000 SO BOTTOM OF DIFFUSER IS WITHIN 6" OF ROOF TRUSS. DUCT CONNECTOR NOTES: 1) M.C. TO COORDINATE DROP SIZES PRIOR TO ORDERING. 2) M.C. TO ADJUST DRUM LOUVER DEFLECTION AND SECURE SET SCREWS PRIOR TO INSTALLATION AS FOLLOWS: ALL BLADES 15' DOWN FROM HORIZONTAL. TWO BLADES EACH 20' OUT FROM VERTICAL. 3) M.C. TO ADJUST DRUM LOUVER BLADES TO DISPERSE SUPPLY AIR EVENLY. SECURE SET SCREWS AT TOP AND BOTTOM OF EACH BLADE PRIOR TO INSTALL. 4) SUPPLY LOW PROFILE PACKAGE ONLY WHERE INDICATED, SEE SHEET M-1.1. 5) FOR INSTALLATION INSTRUCTIONS, CONTACT COIL TECH 0 (509)891-2751. SAFETY CABLE (TYP. OF 4) 20(OPOUT) LOW PROFILE SUPPLY DROP DIFFUSER DRUM RETURN DUCT DROP SECURE BLADE SET SCREWS (TYP.) STOP PIN (TYP. OF 2) (4)SAFETY CABLES AND HARDWARE SUPPLIED WITH EACH DIFFUSER PACKAGE. M.C. TO MAKE FINAL CONNECTIONS AT ROOF STRUCTURE. ROOF, 20 GA, GALVANIZED STEEL 1.5 # INTERNAL LINER EXPANDED ALUMINUM R/A GRILLE 1" MOUNTING (CURB) FLANGE DRUM LOUVER SHIPPED LOOSE, INSTALLED BY M.C. (TYP. OF 2) -3-... 15' ON SECURE DRUM LOUVER SET SCREWS (TYP.) AC DIFFUSER CONFIGURATION & DIFFUSER PACKAGE SCALE: NONE ECONOMIZER WOOD— (E)CONDENSATE D DECK TITS NEW ADAPTER CURB (E)ROOF CURB ROOF SUPPLY AND RETURN DUCT DIFFUSER PACKAGE SUPPUED BY OWNER, INSTALLED BY M.C. SEES; SEE SCHEDULE FOR ITEMS PROVIDED BY OWNER. M.C. TO CONFIRM LENGTH OF SUPPLY AND RETURN DUCT DROPS AND COORDINATE TRANSITION SIZES PRIOR TO ORDERING. FOR INSTALLATION INSTRUCTIONS, CONTACT COIL TECH. (509)891-2751 (E)VENTED P-TRAP ABOVE ROOF. OVIOE SEISMIC BRACING PER LOCAL CODE ADAPTOR CURB CONNECTION PER MANUFACTURER. M.C. TO VERIFY CONDITION OF EXISTING SMOKE DETECTOR(S) AND REPAIR OR REPLACE AS NECESSARY FOR PROPER OPERATION, 18 ROOF MOUNTED AC UNIT W/ ADAPTOR SCALE: NONE DUCTWORK TRUSS (TYP.) DIFFUSER PACKAGE VENTED P-TRAP ABOVE ROOF SEE DETAIL ECONOMIZER H000— CONDENSATE DRAIN ROOF CURB SUPPLY AND RETURN INSTALLED BY M.C. GLULAM DUCT DIFFUSER PACKAGE NOTE COLUMN (1) SEE SCHEDULE FOR ITEMS PROVIDED BY OWNER. SAFELY CABLE SECUR(2) CENTER SUPPLY DUCT FOR UNIT BETWEEN JOISTS. "-- — DUCT PACKAGE AT FACTED ORY.TO DUCT PACKAGE SAFETY CABLE 400011 p M.C. TO WRAP CABLE AROUND TRUSS CHORD ROOF AND CLAMP WIRES (TYP. OF 4) P PROVIDED TH CABLE. EXISTING DROP ATTACH WITH BOLTS IN ALL 4 CORNERS. ATTACH CUPS BETWEEN SCREWS ATTACK DUCTMATE VESA SCREWS(SUPPUED) 14" ON CENTER AND 1" FROM EACH CORNER. NOTES; 1. PROVIDE DIMENSION 'A' AND 'B' TO COIL TECH FOR NEW DIFFUSER. 2. MODIFICATION DUE TO INCORRECT DIMENSIONS WILL BE COVERED AT CONTRACTORS EXPENSE. 3. DUCT CONNECTIONS TO USE DUCTMATE. EXISTING DROP CONNECTION SCALE: NONE ROOF MOUNTED AC UNIT DETAIL SCALE: NONE LOCATE CENTER OF GRAVITY OF UNIT ABOVE COLUMN SUPPLY OFFSET IN SPECIAL ORDER CURB TO AVOID DIFFUSER CONFLICT WITH STRUCTURE. SEE DETAIL v PROVIDE SEISMIC N BRACING PER F+-i LOCAL CODE COUNTER 0 FLASHING PER ARCH. PROVIDE HOLD DOWN CABLE PER DETAIL SEE FIRE PROTECTION o DRAWINGS FOR SMOKE DETECTOR REQUIREMENTS. U] PROVIDED BY FIRE ALARM rn CONTRACTOR INSTALLED BY M.C. (SEE SPEC FOR FIRE ALARM CONTRACTOR RESPONSINNJTY) VAC SCHEDULE, LEGEND AND DETAILS 0) F HVAC HEAT PUMPS > to O w /A1 A wma AO CA CC AL LA. oGFzx.. ciD CD g00 CD F� o En o CD CDF M ® 4 REVIEWED FOR CODE COMPLIANCE . APPROVED NOV 252019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 1 9 2019 PEP,/IT CENTER