HomeMy WebLinkAboutPermit PL16-0001 - VIETNAMESE MARTYRS PARISH / TRUNG DANIEL NGUYEN - CARGO CONTAINERVIETNAMESE MARTYRS
PARISH -CARGO CONTAINE
SITE APN: 3623049087
APPROVED
PARENT PROJECT NO: PL16-0001
PROJECT N O : L16-0001
City of Tukwila
Allan Ekberg, Mayor
Department of Community Development — Jack Pace, Director
NOTICE OF DECISION
Issued February 10, 2016
FILE NUMBER: L16-0001
OTHER FILE #: PL16-0001
TYPE OF APPLICATION: Special permission from the Director to locate one cargo container
LOCATION: Vietnamese Martyrs Parish
6841 South 180th Street, Tukwila, WA 98188
Parcel # 3623049087
ZONING: Tukwila Urban Center — Workplace District (TUC — WP)
APPLICANT: Trung (Daniel) Nguyen
8800 39th Avenue S, Seattle, WA 98118
STAFF: Alec Singer, Planning Intern
ATTACHMENT: A. Site plan prepared by Broderick Architects for 2016 Location
B. Project proposal by Broderick Architects & Applicant
C. Revised Site map with Container placement for 2017 and beyond
BACKGROUND
1. On January 6, 2016, the applicant submitted an application for Special Permission from the Director to
temporarily place one cargo container at 6841 South 180th Street, Vietnamese Martyrs Parish.
2. The Vietnamese Martyrs Parish property is zoned Tukwila Urban Center — Workplace District (TUC — WP), with
a Shoreline overlay. Tukwila Municipal Code (TMC) 18.28.030 permits cargo containers as an accessory use in
the TUC — WP zone provided they obtain special permission from the Director and meet the requirements of
TMC 18.50.060. The Shoreline overlay requires a 125' buffer from the Ordinary High Water Mark (OHWM) for
the leveed portions of the Green River.
3. TMC 18.50.060 (C) notes the following requirements in order to place a cargo container in the TUC-WP zone:
A. Only two cargo containers will be allowed per lot, maximum length of 40 feet.
B. The container is located to minimize visual impact to adjacent properties, parks, trails and right-of-way
as determined by the Director.
C. The cargo container is sufficiently screened from adjacent properties, parks, trails and rights -of -way, as
determined by the Director. Screening may be a combination of solid fencing, landscaping, or the
placement of the cargo containers behind, between or within buildings.
D. If located adjacent to a building, the cargo container must be painted to match the building's color.
E. Cargo containers may not occupy any required off-street parking spaces.
F. Cargo containers shall meet all setback requirements for the zone.
Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov
L16-0001 Notice of Decision
2/10/2016
Page 2
G. Outdoor cargo containers may not be refrigerated.
H. Outdoor cargo containers may not be stacked.
4. The application materials submitted to the City included a site plan showing the proposed cargo container on
the southern corner of the property. The container is proposed for only 2-3 months in a year. In 2016 the
container is temporarily proposed at the location on Exhibit A. Starting in 2017 the container shall be situated at
the indicated location on Exhibit D. The proposed location meets TUC — WP setback requirements and the
location provides screening from existing landscaping.
DISCUSSION
It is the burden of any individual seeking land use approval to clearly demonstrate that: they can meet
application requirements before having the application issued. The applicant has met this burden. The applicant
provided a site plan that clearly demonstrates the proposed cargo container location and how it meets length,
setback, and screening requirements. The applicant has also committed to provide additional screening with the
placement of 5' potted plants (Thuja Occidentalis) and to paint the cargo container the same color as the
adjacent building. The proposed cargo container will occupy three on -site parking stalls. The property must
provide 238 parking stalls pursuant to TMC 18.28.080 off-street parking standard and currently provides 241
parking stalls. The three occupied stalls will bring the total provided to 238, still meeting the parking
requirement. The applicant intends to place the cargo container on site annually between January and March. In
2017, the applicant agrees to move the cargo container to a revised area to comply with shoreline buffer
requirements. The container will not be refrigerated, will not be stacked, and is not located in an off-street
parking space, thus meeting code provisions as outlined in TMC 18.50.060.
The application to locate one 40 foot container is accepted with the following conditions:
1. Applicant shall obtain a building permit prior to the placement of the container on the site. A building
permit has been applied for the temporary location for this year. A new building permit is required for
the permanent location starting in 2017.
2. Applicant shall schedule a planning inspection after the temporary and permanent installation.
The application to locate one 40 foot container is accepted. This container may be placed.
APPEALS
This Notice of Decision may be appealed to the Hearing Examiner. If there are no valid appeals filed within the
time limit the decision of the Department will be final.
In order to appeal the decision, a written notice of appeal must be filed with the Department of Community
Development within fourteen days of the issuance of the Notice of Decision (2013). The requirements for such
appeal are set forth in the Tukwila Municipal Code 18.116.
Appeal materials shall include:
1. The name of the appealing party.
2. The address and phone number of the appealing party; and if the appealing party is a corporation, association
or other group, the address and phone number of a contact person authorized to receive notices on the
appealing party's behalf.
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwitaWA.gov
L16-0001 Notice of Decision
2/10/2016
Page 3
3. A statement identifying the decision being appealed and the alleged errors in that decision. The Notice of
Appeal shall state specific errors of fact or errors in application of the law in the decision being appealed; the
harm suffered or anticipated by the appellant, and the relief sought. The scope of an appeal shall be limited to
matter or issues raised in the Notice of Appeal.
Any appeal shall be conducted as an open record hearing before the Hearing Examiner. The Hearing Examiner's
decision on the appeal is the City's final decision. A party who is not satisfied with the outcome of the
administrative appeal process may file an appeal in King County Superior Court from the Hearing Examiner's
decision pursuant to the procedures and time limitations set forth in RCW Chapter 36.70C.
Minnie Dhaliwal, Planning Supervisor
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
Attachment
END POINT OF
FLOOD PROTECTION
LEVEE EASEMENT
40 Fact rach 2 Rol -Up CorsC
40' X 8CARGO CONTAINER
TEMPORARY LOCATION
OCCUPIES (3) PARKING
STALLS - NONE OF WHICH
ARE REQUIRED. SCREENED
BY (20) POTTED PLANTS -
5 GAL CONTAINER - 5' TALL
MIN.
CONTAINER TO BE WHITE IN
COLOR TO MATCH
BUILDING WALL COLOR.
EXISTING CHURCH
6" DEC.
EXISTING CHAIN
LINK FENCE
EXISTING LAWN
÷4. OC`
Q
0" 0
/
/
z
....)
cp
c-K ---i
TOE OF
Attachment B
PBRODERICK
ARCHITECTS
January 5, 2016
Jerry E. Hight MCP
Building Official / City of Tukwila
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
RE: Church of the Vietnamese Martyrs / 6801 S. 180`h' Street
Dear Mr. Hight,
Pursuant to our conversation this afternoon, the proposed cooking container project the Church of the
Vietnamese Martyrs is seeking to re -permit is identical to the project permitted last year. As such, I have
no issues with the parish re -using our stamped drawings when applying for the 2016 permit.
I do appreciate you and your staffs diligence and thoroughness in processing our permit documents.
Please let me know if you have questions or concerns.
Sincerely,
Kevin J. Broderick, AIA
Deb- 000,
RECEIVED
CITY OF TUKWILA
JAN 0 6 2016
PERMIT CENTER
55 South Atlantic Street • Suite 301 • Seattle, WA 98134 • 206.682.7525 / Fax. 206.682.7529
BiU.Rambo
From: Jerry Hight
Sent: Wednesday, January 06, 2016 8:28 AM
To: Bill Rambo; Kevin Ellis
Subject: FW: Vietnamese Parish Cooking Container Permit
Attachments: Jerry Hight 1.5.16.pdf; ATT00001.htm
fyi
From: Kevin Broderick[mailto:kevin@broderickarchitects.com]
Sent: Tuesday, January 05, 2016 5:22 PM
To: Jerry Hight
Subject: Vietnamese Parish Cooking Container Permit
Hi Jerry,
Thank you for your time this afternoon. Attached is the memo we discussed regarding the parish re -using our
stamped drawings from last year's cooking container permit application. Please let me know if there is
anything else you need to keep the permit application moving along.
Thank you,
Kevin
Kevin J. Broderick AIA, Principal
BRODERICK ARCHITECTS
55 S. Atlantic St, Suite #301
Seattle, WA 98134 206.682.7525
www.broderickarchitects.com
Ari.acleci Eec^ro i Hies Disclaimer - r ,es,ese elecSohic tiles are: 0e ded exc. - F to tacilitaIe th,:i work k ell aura ti ie.r ..i r :k Ar h tect , i
t is ac ecy or alid0 o these ri, i 1 . v ?li t rn iri the - rah. - : c (� lC rr _iles ees Ki
� i _ 'lIP �UBf ti L r,�. ri �F._ b. i ij la �.. I� i r LI"`"'_C '1 al'•aI! these if ._ til
es to
tfa[7 S"9r J_. IC' 81'y ()the, aa,Ll+ v'. moUi ire .::Ck'1re5, wriTter, tio-r ,:_sIot Fi I'oUe ..., fi rCl e--.:t.,. Use ,i ih_sC la .i irtpti IIT � IC, d4r<_.. Ti.'rt tc the @JJI
bt(r000S
1
RECEIVED
CITY OF TUKWII.'
JAN062D
PERMIT CENTEI
TONG GIRO PHAN SEATTLE
GIAO xis' CAC THANH TIC' DAO VIVT NAM
Vietnamese Martyrs Parish of The Archdiocese of Seattle
6841 S. 180th St, Tukwila, WA 98188
Phone: (206) 325-5626 Fax: (206) 324-5849
Website: www.vnccs.org
January 4, 2016
City of Tukwila
6200 South Center Blvd
Tukwila, WA 98188
Attn: Mr. Jerry E. Hight, Building Official
Mr. Jerry E. Hight, MCP
Per the discussion during our last meeting on August 11, 2015, the Vietnamese Martyrs Parish is asking your assistance
to prepare the ethnic food in celebration of the next coming Lunar New Year. We propose a shipping container as a
shelter to prepare the "Banh Chung" ethnic food as follow:
1. The cooking activity will last from January through March annually.
2. Food preparation will be in the existing kitchen, inspected and approved by King County Health Department.
3. There will be ten VulcanVSP 100 kBTU, 2 Ring Burner appliances inside the cooking shelter. Each day, starting
around 5 PM, these burners will be loaded with 55 gallons barrels which contain the rice cake (Banh Chung) and
boiled overnight. There will be three attendants each night to watch the flame and ensure sufficient boiling
water in each barrel to prevent fire hazard. One person will inspect the cooking barrel while the other two stay
alert to assist. They will stay in the existing building and check the cooking shelter once each hour.
4. To prevent the heat build-up inside the cooking trailer, in addition to the attached ventilation plan, the three
access doors will be open to serve as supply air, also allowing the attendant to check the flame and heat prior
enter the shelter to check the boiling water barrel.
5. After each shift, the rice cakes are removed, cooled, and move back into the main kitchen for final wrapping and
refrigerate and finally distribute among church members to be consume at their own residence as part of Lunar
New Year celebration.
As you may already be aware, we have used the same method last year and also many prior years at our previous
location In Seattle without incident. Please do not hesitate to contact our technical representative, Kevin Broderick at
(206) 682-7525 or myself at (206) 369-1061 if you have any further questions or advice.
Best Regards,
Trung T. uyen
Vietnamese Martyrs Parish's Member
Quo- ooos
RECEIVED
CITY OF TUKWILA
JAN 0 6 ^^"
PERMIT CENTE
B RODERICK
ARCHITECTS
January 26, 2015
Jerry E. Hight MCP
Building Official / City of Tukwila
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
RE: Church of the Vietnamese Martyrs / 6801 S. 180`r' Street
Dear Mr. Hight,
Pursuant to your email dated 1/9/15 and our subsequent telephone conversation we have the following
response to your list of concerns:
Plans are to reflect the following prior to permit submittal:
1. Provide seismic anchorage of the cargo container
Structural calculations which outline adding ballast to the container are attached.
2. Provide Type 11 hood plans (with exhaust calculations)
Per our conversation, since the container is a steel, non-combustible structure it is. itself acting as a Type II
hood, the exhaust calculations are included on the attached drawing.
3. Provide hood exhaust clearances to building/intakes
There are no operable windows, doors or mechanical intakes within
4. Makeup air to be sized same as exhaust hood
A note stipulating that the overhead doors will be in an open position whenever there is cooking and the
exhaust fans are on has been added to the attached drawing.
5. Gas pipe sizing (1,100,000 btu's) from unit to gas meter
Gas pipe sizing and demand calculations are included on the attached drawings.
6. Electrical panel and wiring plan
An electrical permit will be obtained for the power associated with lighting and the exhaust fans. A
preliminary diagram is attached for your consideration..
7. Cargo manufacture manual/listing indicating acceptable cooking appliance installations
have contacted two cargo manufacturers and there is no specific listing for cooking appliance
installations. However, they did note that the City of Tukwila has already approved the use of a cargo
container as a restaurant / cooking facility at the Starbucks located at 10100 East Marginal Way. I am not
sure given the temporary nature of the intended use and the fact that we are talking about a pre -
manufactured structure what else we can do to alleviate your concern.
Also attached is a letter from the parish outlining the temporary use of the facility, cooking methods and a
detailed description of the use.
Please let me know if you have questions or concerns. RECEIVED
Sincerely, CITY OF TUKWILA
b I.crjA'� JAN 0 6 2016
Kevin J. Broderick, AEA
55 South Atlantic Street • Suite 301 • Seattle, WA 98134 • 206.682.7525 / Fax. 206.682.7529 ERMIT CENTE4''
I.L. GROSS
STRUCTURAL ENGINEERS
Vietnamese Martyrs
Cargo Container
Tukwila, WA
Structural Uplift Analysis Calculations
January 19, 2014
23914 56f° Ave W. - Suite # 200
Mountlake Terrace, WA 98043
Ph. (206) 623-0769 • (425) 640-7333
I.L. Gross Structural Engineers
23914 56th Ave West
Project Title: Vietnamese Martyrs Cargo Container
Engineer: VM Project ID:
Project Descr: Uplift Analysis on Temporary Cargo Container
Prina2d 17 JA?r 2015, 2 ACFFd
ASCE Seismic Base Shear
Lic. # : KW-06002858
Fie = v-lA5AQ92-EW20PHHDtCStQ59-21CS1Q59 -2,EC6
ENERCALC, INC.1983.2015, Bu9d.6.15.1.6, Ver6.15.1.6
Licensee : I.L. GROSS STRUCTURAL ENGINEERS
Cargo Container base Shear
Risk Category
Risk Category of Building or Other Structure : 'II' : All Buildings and other structures except those listed as Category 1,111, and IV
Seismic Importance Factor
USER DEFINED Ground Motion
1
Max. Ground Motions, 5% Damping
ss
S1
1.403 g, 0.2 sec response
0,5230 g, 1.0 sec response
, Site Class, Site Coeff. and Design Category
Site Classification 'D" : Shear Wave Velocity 600 to 1,200 ft/sec
Site Coefficients Fa & Fv
(using straight-line interpolation from table values)
Maximum Considered Earthquake Acceleration S = Fa ' Ss
MS
S Mt =Fv'S1
Design Spectral Acceleration
Seismic Design Category
Resisting System
Basic Seismic Force Resisting System .. ,
Response Modification Coefficient ' R
System Overstrength Factor ' Wo'
Deflection Amplification Factor ' Cd
Fa
Fv
DS MS
SDS M1 2I3
Bearing Wall Systems
Light -framed walls with
NOTE! See ASCE 7-10 for all applicable footnotes.
2.00
2.00
2.00
= D
1.00
• 1.50
• 1.403
= 0.785
• 0.935
• 0,523
• D
shear panels of all other materials
Building height Limits :
Category'A & B" Limit:
Category'C' Limit
Category "D` Limit:
Category 'E' Limit:
Category'F' Limit:
No Limit
No Limit
Limit = 35
Not Permitted
Not Permitted
Calculations per ASCE 7-10
ASCE 7.10, Page 2, Table 1.5-1
ASCE 7-10, Page 5, Table 1.5-2
ASCE 7-10 11.4.1
ASCE 7-10 Table 20.3-1
ASCE 7-10 Table 11.4-1 & 11.4-2
Redundancy Factor
Seismic Design Category of D, E, or F therefore Redundancy Factor' p' = 1.3
Lateral Force Procedure
Equivalent Lateral Force Procedure
The 'Equivalent Lateral Force Procedure is being used according to the provisions of ASCE 7-1012.8
Determine Building Period - -
Structure Type for Building Period Calculation : All Other Structural Systems
▪ Ct' value
0.020 ' hn ' : Height from base to highest level = 8.50 ft
• x•value = 0.75
• Ta' Approximate tundemental period using Eq. 12.8-7 :
'TL' : Long -period transition period per ASCE 7-10 Maps 22-12 -> 22-16
Cs"Response Coefficient
S DS: Short Period Design Spectral Response
R ▪ ' : Response Modification Factor
' I' : Seismic Importance Factor
Ta=Ct•(hn "x) = 0.100 sec
6.000 sec
Building Period' Ta `Calculated from Approximate Method selected
ASCE 7-10 Eq. 11.4-1
ASCE 7-10 Eq. 11.4.2
ASCE 7-10 Eq. 11.4-3
ASCE 7-10 Eq. 11.4-4
ASCE 7-10 Table 11.6-1 & -2
ASCE 7-10 Table 12.2-1
ASCE 7-10 Section 12.3.4
ASCE 7-10 Section 12.8.2
Use ASCE 12.8-7
= 0.100 sec
ASCE 7-10 Sechon 12.8.1.1
0.935 From Eq. 12.8-2, Preliminary Cs
2.00 From Eq. 12.8-3 & 12.8-4 , Cs need not exceed
1 From Eq. 12.8-5 & 12.8-6, Cs not be less than
User has selected ASCE 12.8.1.3 : Regular structure, Cs : Seismic Response Coefficient =
Less than 5 Stories and with T «= 0.5 sec, SO Ss <=1.5 for Cs calculation
• 0.468
• 2.627
• 0.041
= 0.4677
I.L. Gross Structural Engineers
23914 56th Ave West
Project Title: Vietnamese Martyrs Cargo Container
Engineer: VM Project ID:
Project Descr: Uplift Analysis on Temporary Cargo Container
IBC 2012 1609.6 Alternate All -Heights Wind
Lic. # : KW-06002858
Description : -None-
: Analytical Values -
User verified these IBC 2012 All -Heights Wind Method Limitations :
1609.6.1 (1) : Total Height <= 75 ft with (Height! Least Width) <= 4
-or- Fundamental frequency>= 1 hertz
1609.6.1 (2) : Not sensitive to dynamic effects
1609.6.1 (3) ; Site not affected by channeling/buffeting from upwind items
1609.6.1 (4) : Simple diaphragm building per ASCE 7-05 Sec 26.2
1609.6.1 (5) : Aware of ASCE 7 provisions for open buildings, multispan gable
roofs, stepped roofs, sawtooth roofs, domed roofs, roofs with
slopes > 45 deg, solid free standing walls & signs.
1609.6.4.1 : Aware of need to check torsion per ASCE 7 Fig. 27,4.8
MWIFRS fable per IBC 2012 1609.E 2, Section 1
WINDWARD WALLS & PARAPETS
Kz based on ibc 2012 1609.6.4.2 Item 1
Height
0-15'
20'
25'
30'
40'
50'
60'
70'
80'
90 '
100'
LEEWARD & SIDEWALLS
Kz based on IBC 2012 1609.6.4.2 Item 2
Leeward Wall
Side Wall
Parapet Wall : Leeward
Pared 17 JAN 2015, 11 52AM
File =t A492-EtV20PH I-O CSIQ59-2 cstQ59-2EC6
ENF..RCALC, INC.1983.2015, euitd:6.15.1.6, Vec6.15.1.6
Licensee : I.L. GROSS STRUCTURAL ENGINEERS
Calculations per IBC 2012 1609.6
Analytical Values .. .
Exposure Category, ASCE 7-10 Sect 26.7.3 Exposure B
Mean Roof Height 8.50 ft
Topographic Factor per ASCE 7-10 Sec 26.8.2
K1 = 0.250 K2 = 1.0 K3 = 1.0
Force Kzt to 1.0 per ASCE 7-10 26.8.2 Yes
Topographic Factor Kzt = (1+K1*K2*K3)^2 = 1.000
V : Basic Wind Speed 115.0 mph
per ASCE 7-10 26.5.1
WALLS
Design Pressure P = 0.00256 VA2 K C K
z net zt
PARAPETS psf ----
Enclosed Partially Enclosed
Kz +Internal -Internal +Internal -Internal Enclosed
0.570 8.32 14.13 2.13 20.32 24.77
0.620 9.05 15.37 2.32 22.10 26.94
0.660 9.64 16.36 2.46 23.53 28.68
0.700 10.22 17.35 2.61 24.95 30.42
0.760 11.09 18.84 2.84 27.09 33.03
0.810 11.82 20,07 3.02 28.87 35.20
0.850 12,41 21.07 3.17 30,30 36.94
0.890 12.99 22.06 3.32 31.73 38.68
0.930 13.58 23.05 3.47 33.15 40.41
0.960 14.01 23.79 3,59 34.22 41.72
0.990 14.45 24.54 3.70 35.29 43.02
Enclosed Partially Enclosed
+Internal -Internal +Internal -Internal
0.570
-9.87
-12.77
Both Directions
-4.06 -16.06
-6.77 -18.77
-16.45 Both Directions
2.13
0.77
-16.45
Partially Enclosed
24.77
26.94
28.68
30.42
33.03
35.20
36.94
38.68
40.41
41.72
43.02
o, ad f ER- Ark- Coxrre(1 /Z-
40 foot with 2 Roll -Up Doors
40' X 8' CARGO CONTAINER
TEMPORARY LOCATION
OCCUPIES (3) PARKING
STALLS - NONE OF WHICH
ARE REQUIRED. SCREENED
BY (20) POTTED PLANTS: 5'
THUJA OCCIDENTALIS
(SMARAGD) IN POTS,
CARGO CONTAINER TO BE
WHITE IN COLOR TO MATCH
BUILDING WALL COLOR.
Pgt'
H�'1 ��.1G
V 6Z A5D = qi6At'r3 yO17-7 q,314‘
kitApto z q
\Lai) -,7Y tHs✓mst ^ 22 Qri x *ix B = 7 480 ';.O► 6
U PL4fr (S)
yu'r 8,S',6
EA!
1.01
0,6 - O,fLf Soy x= 0,6—D,/if(0,936)
o1io-D
go✓6AfirS
0400
City of Tukwila
Department of Community Development
File Number
LAND USE PERMIT ROUTING FORM
TO: 'Building Li Planning=Public Works a Dept.
I❑I
Police Dept. L❑.J Parks/Rec
Project: ,
L
1(o_ Om 1 a 1 b_i�00\)
Address:
(0 .e.i 1 5 1
iid4 ql%/
Date
transmitted:
�50i)Q.
1 / I ?j I i,F'�
Response
requested by:
1/9)\0/169
Staff
coordinator:
C
(\ if C Ji r tc,f?(
Date response
received:
REVIEWERS: Please specify how the attached plans conflict with your ADOPTED
development regulations, including citations. Be specific in describing the types of changes you
want made to the plans. When referencing codes, please identify the actual requirement and
plan change needed.
The Planning Division review does not supplant each department's ability to administer its own
regulations and permits. However, project consistency at the Planning review stage is
important to minimize significant later design changes. More than minimal design changes
require further Planning Commission review, even if alteration is required to satisfy a City
requirement. This further review is typically a minimum 60-day process.
Requirements based on SEPA (e.g., not required by an adopted development regulation)
MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the
method used to calculate the mitigation required. Calculations of project impacts and the
mitigation required (e.g., water capacity, road level of service analyses, or turning analyses)
may be required of the applicant.
COMMENTS
(Attach additional comment sheets and/or support materials as needed.)
Plan check date: Comments
/y'�� prepared by:
Update date:
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670
SPECIAL
PERMISSION -
DIRECTOR
APPLICATION
FOR STAFF USE ONLY Permits Plus Type: P-SP
Planner:
File Number: L / (r COO l
Application Complete Date:
--'4Z61 /
Project File Number: '/) /
Application Incomplete Date:
Other File Numbers:
��JJ
NAME OF PROJECT/DEVELOPMENT: V j Ylq wll 5C_ N4 c4r 5 Park 04 [\) M
BRIEF DESCRIPTION OF PROJECT: 10 I a� 2 a ccr Gov t 'v\ pk„ p010," o�
LOCATION OF PROJECT/DEVELOPMENT: Give street address of vacant, indicate lot(s), block and
subdivision, access street, and nearest intersection.
LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement).
3G-. O q o7
ECE VEED
JAN 06 2016
Community
Development
DEVELOPMENT COORDINATOR :
The individual who:
• has decision making authority on behalf of the owner/applicant in meetings with City staff,
• has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards,
and
• is the primary contact with the City to whom all notices and reports will be sent.
Name:
Address:
Phone:
E-mail:
Signature:
N1J ( kt
P3sO � 3�l k�' _ � spa 44�� c,w1— gg i
o Icb
C5C(pCog — 16 Cp l FAX:
o,►� `1 I c tin co (
Date: a t'D Sol Y'
H:\Applications needing fee verbiage\Special Permission Director -March 2011.docx
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670
AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS
PERMISSION TO ENTER PROPERTY
STATE OF WASHINGTON
COUNTY OF KING
The undersigned being duly sworn and upon oath states as follows:
1. I am the current owner of the property which is the subject of this application.
2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my
knowledge.
3. The application is being submitted with my knowledge and consent.
4. Owner grants the City, its employees, agents, engineers, cizntraciors or other representatives the right to enter upon Owner's real
property, located at c-,. 441 �. f f{3(2,tt► St-- t kkICkkril A tAn4 q271- l S Q') for the purpose of application review,
for the limited time necessary to complete that purpose.
5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the
City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City.
6. Non -responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without
refund of fees.
EXECUTED at I ,A 14-kW i' CI
SS
(city), Vi 4 (state), on f I O co
LAURIE A. WERLE
NOTARY PUBLIC
STATE OF WASHINGTON
COMMISSION EXPIRES
MAY 29, 2018
RECEEV D
'* 06 2616
Community
Development
, 20
(Print NamJ
(A dress)
) 3c�i — (00)1
c..(Ptione er)
(Signatu
c„,14-1-10 Gefie,
On this day personally appeared before me %vYC9- 1 /1Ctdl 11 )•-1 944 �� V to me known to be the individual who
executed the foregoing instrument and acknowledged that he/she signed the same as his/her voluntary act and deed for the uses and
purposes mentioned therein.
SUBSCRIBED AND SWORN TO BEFORE ME ON THIS DAY OF
Y PUBLIC
residing at
My Commission expires on
H:\Applications needing fee verbiage\Special Permission Director -March 2011.docx
•
COMPLETE APPLICATION CHECKLIST
The materials listed below must be submitted with your application unless specifically waived in writing by the Public Works
Department and the Department of Community Development. Please contact each Department if you feel that certain items
are not applicable to your project and should be waived. Application review will not begin until it is determined to be
complete. ADDITIONAL MATERIALS MAY BE REQUIRED.
The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require
additional information as needed to establish consistency with development standards.
City Staff are available to answer questions about application materials at 206-431-3670 (Department of Community
Development) and 206-433-0179 (Department of Public Works).
Check items
submitted
with
application
Information Required. May be waived in unusual cases, upon approval of both Public Works and
Planning
APPLICATION MATERIALS:
�,%
1. Application Checklist one (1) copy, indicating items submitted with application.
2. Application Fee: See Land Use Fee Schedule.
3. Written description of the project, the deviation or approval being requested and response to the
applicable decision criteria.
ZONING CODE PARKING DEVIATION
4. A complete description of the proposed construction relative to parking areas, and all supporting
agreements.
5. Dimensional site plan(s) to demonstrate parking area consistent with Zoning Code requirements.
6. Parking studies as needed to demonstrate adequate parking is provided.
LANDSCAPE DEVIATION
7. Landscape plan — two (2) copies showing size and species of existing and proposed plant materials,
required perimeter landscape types, parking areas, buildings, walkways, transit facilities, property lines,
dimensions and area of planting beds and any calculations necessary to demonstrate compliance with
review criteria.
SENSITIVE AREA ORDINANCE - Deviations, Alterations or Uses Requiring Administrative Review and Approval
8. Site Plan — two (2) copies showing all buildings, parking areas, walkways, property lines, planting
areas, sensitive areas, their buffers and setbacks.
9. Sensitive area studies, mitigation and enhancement plans to justify a requested use, deviation, alteration
or buffer or setback reduction and demonstrate that the reduction will not result in a direct or indirect short-
term or long-term adverse impact to the sensitive area per TMC 18.45.090(D) or 18.45.110(C). See TMC
18.45.040(B) for required element s of wetland and/or watercourse sensitive area studies and TMC
18.45.040(C) for the required elements of a geotechnical report.
\\deptstore\City Common\Teri\Revisions In Progress\Special Permission Director -March 2011.docx
Check items
submitted
with
application
Information Required. May be waived in unusual cases, upon approval of both Public Works and
Planning
CARGO CONTAINER APPROVAL
` 1
�J /
10. Site plan showing the location of the container(s) in relationship to parking areas, property lines,
buildings, streets, trails, landscape areas and setbacks.
v /
11. Description of the proposed screening.
'
12. Dimensions of proposed cargo container.
SINGLE-FAMILY DESIGN STANDARD EXCEPTIONS
13. Dimensioned and scalable building elevations with keyed colors and materials.
14. The site plan must include a graphic scale, north arrow, proposed house footprint, any existing
structures, lot lines, setbacks, adjacent streets, driveways, parking areas, any sensitive areas and any fences,
rockeries or retaining walls.
\\deptstore\City Common \Teri\Revisions In Progress\Special Permission Director -March 201 I.docx
Revi9A, (0111tAiyo ao17
PARCEL #3623049094
-112112 POINT OP BEGINNING'
6 -POINT
1=1.117 FENCE—
GREEN RIVER ^^
tl
w
cD ARCHITECTURAL SITE PLAN
ORO
1 I —
63u201 POMO Puxrsr
OC ' I=w ro e
ROOD remeirwr� _ �/
PARCEL # 3623049017
/3118.0
1£ 1
6
/.,
TOE Oi SLOPE
• /
PROJECT NOTES
LEGAL 08-9C81813341
raaw6 !!Z ucoaoxruxE. oA fItg.6am.'x."
MOO. CM. 3014441.8 TOM 5-GALLON POMP PUNTS A
E06.68x3e18,
tax tnc't�u trues r.�rr,e....em
70•20-07 220 'I' MA TO TrOlf TOM ISM. NI" IN PWVAIL
PLANNING NOTES
orxuw 334.0 61 1617 MAC.
,m 88.A . 6 2506. a6) 61.66wa101.
8341.8.1110
,.II.E...6Ea6ur6,
6118:1r3 I� :1 =1744.srro sewe1E Nt[81
33.581.181111
CON.611 CUM
30331.16 WOO.
msmlc 16[661ro ¢Nup
02/04/16
561
C1
6801 S. 180TH STREET • TUKWILA, WA 68188
Copyright 0 Thursday, October 23, 2014 by Broderick Architects, pllc
This document represents a proprietary design owned by the architect and shall not be used on other projects or additions to this project or for completion of this project by others except by prior a
•
•
•
\
PARCEL # 3623049094
EXISTING 5'
sA \ CHAIN LINK FENCE-
9< A
9�y �
\
\
\
GREEN RIVER
EDARCHITECTURAL SITE PLAN
1" = 30'
PSpNp.o ??'K\NG
\
"TRUE POINT OF
BEGINNING"
& "POINT A"
\
i
END POINT OF
FLOOD PROTECTION
LEVEE EASEMENT
0
zo
•
¢>
- 0
Q
ww
oU)
w
00
z
w
ZEr)
w°L
�w
CZ I
w
48'-O"
(
EXISTING ASPHALT
PARKING, TYP.
EXISTING LAWN
24"glNE
HERR
0
40' X 8' CARGO CONTAINER
TEMPORARY LOCATION
OCCUPIES (3) PARKING
STALLS - NONE OF WHICH
ARE REQUIRED. SCREENED
BY (20) POTTED PLANTS -
5 GAL CONTAINER - 5' TALL
MIN.
CONTAINER TO BE WHITE IN
COLOR TO MATCH
BUILDING WALL COLOR.
Min
EXISTIN
16" CI-E
HERRY
EXISTING CHURCH
WINO Ma 411,
PARCEL # 3623049017
' 4 STALLS
an 9_-Q" X 19'-0"
12"0FIR
sel
" FIR
EXISTING
CONCRETE
PATIO
16" FIR
0
FRONT SETB
0
24" CEDAR
EXISTING LAWN
EXISTING CHAIN
LINK FENCE
EXISTING LAWN
7
i
/
i
1
1
TOE OF SLOPE
/
0
GA
i
30'
i
i
I
PROJECT NOTES
60'
PROJECT ADDRESS: 68015.180TH STREET.
TUKWILA, WA 98188
PROJECT DESCRIPTION:
OWNER:
ARCHITECT:
PLACEMENT OF (1) CARGO CONTAINER ON SITE AT SOUTH PARKING
LOT. CONTAINER TO MATCH BUILDING WALL COLOR. SCREENING
AROUND CARGO CONTAINER TO BE 5-GALLON POTTED PLANTS A
MINIMUM OF 5' TALL.
CORP. OF CATHOLIC ARCHBISHOP OF SEATTLE / ED FOSTER
719 9TH AVE
SEATTLE, WA 98104
206.382.4560
BRODERICK ARCHITECTS
55 S. ATLANTIC STREET, SUITE 301
SEATTLE, WA 98134
206.682.7525
206.682.7529 (F)
CONTACT: KEVIN BRODERICK kevin@broderickarchitects.com
STRUCTURAL ENGINEER: I.L. GROSS STRUCTURAL ENGINEERS
23914 56TH AVE WEST, SUITE 200
MOUNTLAKE TERRACE, WA 98043
206.623.0769
LEGAL DESCRIPTION:
PARCEL NUMBER:
CONTACT: IRA GROSS ira@ilgross.com
BEG AT NW COR SEC 36 TH 5 01-19-01 W 1320.01 FT TO NW COR OF GL
4 TH 5 88-04-53 E 381.81 FT TH 5 01-55-07 W 341 FT TH N 88-04-53
W 50 FT TO TPOB TH 5 88-04-53 E 426 FT M/L TO TOP OF LEFT BANK
OF GREEN RIVER TH 5 07-00 E 106 FT TH 5 01-06 W 104 FT TH 5 09-12
W 106 FT TH 5 26-49 W 102 FT TH 5 47-21 W 103 FT TH 5 60-15 W 40 FT
TH 5 74-35 W 60 FT TH W 106 FT TH N 67-30 W 107 FT TH N 26-19 W
104 FT TH N 20-22 W 103 FT TH N 21-54 W 105 FT TH N 32-38 W 116 FT
TH N 44-04 W 35 FT M/L TAP FR WH TPOB BEARS 5 70-20-07 W TH N
70-20-07 E 220 FT M/L TO TPOB TGW ESMTS TGW UND INT IN PRIVATE
RD ADJ FOR ASSESSMENT PURPOSES
3623049087
PLANNING NOTES
ZONING:
LOT AREA:
LOT COVERAGE:
PARKING:
TUC
251,300 SF (5.77 ACRES)
62,250 SF (25%) BUILDING TOTAL
EXISTING: 241 STALLS
PROPOSED: 238 STALLS
REQUIRED:
ASSEMBLY AREA: (1 PER 4 FIXED SEATS)
NAVE: 733 SEATS/ 4 =184 STALLS
BUSINESS: (3 PER EACH 1000 SF OF USEABLE AREA)
OFFICES: 4242 SF / 333.33 =13 STALLS
EDUCATION: (1.5 PER EA. STAFF, 27 CLASSES = 27 STAFF)
CLASSROOMS: 1.5 X 27 = 41
TOTAL REQUIRED PARKING: 184+13+41 = 238 STALLS
BIKE PARKING:
8 STALLS MINIMUM
LEGEND:
PROPERTY LINE
EASEMENTS
EXISTING FENCE
8" CONCRETE CURB
SETBACK
ORDINARY HIGH WATER MARK
TOE OF SLOPE
EXISTING LANDSCAPE AREAS
EXISTING BUILDING
DIRECTION OF TRAVEL
EXISTING HYDRANT
EXISTING TREES (TO REMAIN)
RECEIVED
JAN 06 2010
Community
Development
-
V�
W2
OtZ
i
z
o.
ti
o�
WV
W�
�V
iz
N
of
N
1
1
VIETNAMESE MARTYRS:
TENANT IMPROVEMENT
6801 S. 180TH STREET 0 TUKWILA, WA 98188
I
B I
12.040 Plot Date: 10/23/14 John Faley 14.012 CARGO CONTAINER PERMIT.pin
J I LL
_I
if) w
c/)
ERICK ARCI
O
1
NO. DATE DESCRIPTION
CARGO CONTAINER PERMIT
*
il
I
10/23/14
I
al I
SITE PLAN