HomeMy WebLinkAboutPermit PL16-0041 - RICK CARDOZA / VERIZON - TYPE 1 WIRELESS FACILITIESVERIZON SEA RIVERTON SITE APN: 7349200345 APPROVED PARENT PROJECT NO: PL16-0041 PROJECT NO: L16-0049 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director September 19, 2016 NOTICE OF DECISION TO: Rick Cardoza, Applicant Verizon Wireless, Owner King County Assessor, Accounting Division Washington State Department of Ecology This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. Project File Number: Applicant: Type of Permit Applied for: Project Description: Location: Associated Files: Comprehensive Plan Designation/Zoning District: I. PROJECT INFORMATION L16-0049, PL Rick Cardoza Type 1 Wireless Facilities Permit The applicant is requesting to replace 6 panel antennas (2 per sector) on an existing 120' above ground level monopole. The applicant also proposes to install remove 3 TMAs and add 3 RRUS 11 B13 with A2 units, 3 RRUS 12 B2 A2 with units, 1 OVP distribution box and hybrid cable, and 1 OVP distribution box within an existing shelter. The modifications will not exceed the height of the existing structure and the project is categorically exempt from SEPA [RCW 43.21C.0384(1)(a)]. No ground disturbance or expansion of the existing compound is proposed. 13130 44th Ave S, Tukwila, WA 98168. None Commercial Light Industrial (CLI) Page 1 of 3 9/19/2016 4:38:00 PM II. DECISION SEPA Determination: The City SEPA Responsible Official has previously determined that this application does not require a SEPA threshold determination because it is categorically exempt. Decision on Substantive Permit: The City Community Development Director has determined that the application for a Type 1 Wireless Communication Facilities Permit does comply with applicable City and state code requirements and has approved that application. III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 1 Wireless Communication Facilities permit decision pursuant to Tukwila Municipal Code § 18.104.010. Other land use applications related to this project may still be pending. No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the conditions which were imposed by the MDNS decision or the failure of the Department to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner. A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King County Superior Court from the Hearing Examiner's decision. IV. PROCEDURES AND TIME FOR APPEALING In order to appeal the Community Development Director decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this Decision, that is by October 3'd, 2016. The requirements for such appeals are set forth in Tukwila Municipal Code ch. 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing party's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. Page 2 5. Appeal fee per the current fee schedule, additional hourly charges may apply. In addition all hearing examiner costs will be passed through to the appellant. V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the Hearing Examiner based on the information presented to the Community Development Director, who made the original decision. No new evidence or testimony will be permitted during the appeal hearing. Parties will be allowed to present oral argument based on the information presented to the Community Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW ch. 36.70C. An appeal challenging a DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the subject property. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Max Baker, who may be contacted at 206-431-3683 for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. Otw< Department of Community Development City of Tukwila Page 3 CityofT Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director NOTIFICATION: FILE NUMBER: APPLICANT: PROPERTY OWNER: REQUEST: LOCATION: ASSOCIATED PERMITS: SEPA DETERMINATION: COMPREHENSIVE PLAN DESIGNATION: ZONE DESIGNATION: STAFF: ATTACHMENTS: STAFF REPORT TO THE DIRECTOR PREPARED September 19, 2016 Notification is not required for a Type 1 land use application. L16-0049, PL16-0041 Rick Cardoza, C/0 LDC, Inc. (obo Verizon) Verizon Wireless Approval of a Type 1 Telecommunications Facilities Permit to replace 6 panel antennas (2 per sector) on an existing 120' above ground level monopole. The applicant also proposes to install remove 3 TMAs and add 3 RRUS 11 B13 with A2 units, 3 RRUS 12 B2 A2 with units, 1 OVP distribution box and hybrid cable, and 1 OVP distribution box within an existing shelter. Parcel # 7349200345. This tower is located at 13130 44th Ave S, Tukwila, WA 98168. A separate permit from Public Works shall be required if the construction equipment will be placed inside the City right of way and/or traffic lane/pedestrian path will need to be modified during antenna equipment replacement. Exempt Commercial Light Industrial (CLI) Commercial Light Industrial (CLI) Max Baker, Assistant Planner Project Plans for Permit L16-0049 FINDINGS Vicinity/Site Information Project Description The applicant is requesting to replace 6 panel antennas (2 per sector) on an existing 120' above ground level monopole. The applicant also proposes to install remove 3 TMAs and add 3 RRUS 11 B13 with A2 units, 3 RRUS 12 B2 A2 with units, 1 OVP distribution box and hybrid cable, and 1 OVP distribution box within an existing shelter. The modifications will not exceed the height of the existing structure and the project is categorically exempt from SEPA [RCW 43.21C.0384(1)(a)]. No ground disturbance or expansion of the existing compound is proposed. The project also qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which requires the City to approve any eligible facilities request for a modification of an existing tower or base station that does not substantially change the physical dimensions of such tower or base station. Existing Development This telecommunications facility is preexisting. Surrounding Land Uses The property and surrounding parcels are zoned Commercial Light Industrial (CLI). Background In 2006, the City adopted a Wireless Facilities Chapter to the Zoning Code. The chapter provides specific location and design requirements for the placement of WCF within the City of Tukwila. The TMC was updated in 2016 (TMC 18.58). The WCF being modified is preexisting. The WCF being modified was originally approved by the City in 1992 (PW92-0019). In 2005, the WCF was approved for modifications (L05-045, L05-078) through conditional use permits, in 2010 (L10-057) through a Type 1 Wireless facilities permit, and in 2014 (L14-0019) through a Type 1 Wireless facilities permit. Location Selection Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co - locations and utilizing existing structures are favored over the development of new standalone WCF within the City. MB L16-0049 Staff Report 9/19/2016 2 TABLE A Type of Permit Required, Based on Type of Wireless Communication Facility Zoning(1) Type of Facility Residential Commercial Industrial Adding antennas to an existing tower or utility pole Type 1(2) Type 110) Type 1s2' Eligible facilities modification Type 1 Type 1 Type 1 Utility pole co -location Type 2 Type 2 Type 2 Concealed building attached Type 2() Type 2(3i Type 1 Non -concealed building attached Type 2() Type 2 Type 1 New tower or height adjustment request Type 3(4) Type 3 Type 3 t'I Zoning for any private/public property or right-of-way: Residential — LDR, MDR, or HDR. Commercial — 0, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS_ Industrial — LI, HI, MIC/L, or MIC/H. Qi Provided the height of the tower or utility pole does not increase and the square footage of the enclosure area does not increase. (3) An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.140. 01 MDR and HDR only. The applicant is requesting to replace 6 panel antennas (2 per sector) on an existing 120' above ground level monopole. The applicant also proposes to install remove 3 TMAs and add 3 RRUS 11 B13 with A2 units, 3 RRUS 12 B2 A2 with units, 1 OVP distribution box and hybrid cable, and 1 OVP distribution box within an existing shelter. The modifications will not exceed the height of the existing structure and the project is categorically exempt from SEPA [WAC197-11-800(25)]. No ground disturbance or expansion of the existing compound is proposed. Design Standards The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below indicates if the applicant's proposal complies with required standards. Table 1 (See TMC 18.58.070 for further details) General Requirements Project does comply Project does not comply Not Applicable Notes 1. Generators or other devices which will create noise must comply with TMC 8.22 regarding noise. X No new generator is proposed. 2. Only safety signage must be placed on the WCF. X The applicant does not propose any signage. 3. Accommodations for parking for maintenance personal must be provided. X Parking is not affected by this modification. MB L16-0049 Staff Report 9/19/2016 3 4. Towers shall either maintain a galvanized steel finish or be painted a neutral color so as to reduce its visual obtrusiveness. X No change to the existing tower is proposed. 5. The design of all buildings and ancillary structures shall use materials, colors, textures, screening, and landscaping that will blend the tower facilities to the natural setting and built environment. X No new buildings or structures are proposed. 6. Antennas shall have the same color scheme as the structure they are located on. X The antennas and other equipment will be painted to match the existing tower. 7. WCF poles and towers shall only have safety lights if required by a government agency. X No lighting is proposed. 8. No advertising is permitted on WCF X No advertising is proposed. 9. Each service provider shall be limited to an equipment enclosure of 360 square feet. X No expansion of the existing fenced equipment enclosure is proposed. Table 2 (See TMC 18.58.090 for additional information) Adding Antennas to Existing WCF Tower -Specific Development Standards Project does comply Project does not comply Not Applicable Notes 1. When adding antennas to existing WCF towers, height must not exceed what was approved under the original application to construct the tower. X No change to the previously approved tower height of 120' is proposed. Not applicable under § 6409 of the Spectrum Act. 2. Antennas shall be painted to match the color scheme of tower. X The antennas and other equipment will be painted to match the existing tower color. MB L16-0049 Staff Report 9/19/2016 4 3. There is no limit on the number of antennas that may be located on an existing tower. X No increase in number of antennas. 4. Feed lines and coaxial cables shall be located within the tower. Those exposed shall be painted to match tower. X No new feed lines or coaxial cables proposed. Proposed antennas, equipment and mounting hardware shall be painted to match existing. 5. A new cabinet shall be located within the equipment enclosure that was approved as part of the original application, or it will require a Type 2 decision. X No cabinet is proposed. 6. Setbacks shall not apply when an applicant installs new antennas on an existing tower and uses an existing equipment enclosure. If the equipment enclosure is increased, it must meet setbacks. X There is no change to the existing equipment enclosure. CONCLUSIONS 1. The proposed modifications to the existing WCF will not significantly alter the conditions that currently exist and will not be materially detrimental to the public welfare or injurious to property or improvements in the vicinity. 2. As demonstrated in Tables 1 and 2, the project meets all applicable development standards for a Type 1 WCF. 3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian circulation, building or site design. 4. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan. 5. A separate permit from Public Works shall be required if the construction equipment will be placed inside the City right of way and/or traffic lane/pedestrian path will need to be modified during antenna equipment replacement. 6. The project qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which requires the City to approve any eligible facilities request for a modification of an existing tower or base station that does not substantially change the physical dimensions of such tower or base station. MB L16-0049 Staff Report 9/19/2016 5 RECOMMENDATIONS The recommendation to the Director of Community Development is to approve this application for a Type 1 Wireless Telecommunications Facility permit as applied for C/O LDC, Inc. for Verizon INFORMATIONAL ITEMS A separate permit from Public Works shall be required if the construction equipment will be placed inside the City right of way and/or traffic Zane/pedestrian path will need to be modified during antenna equipment replacement. Contact Joanna Spencer at (206) 431-2440 to get more information about requiirements for the construction equipment permit. MB L16-0049 Staff Report 9/19/2016 6 0400 City of Tukwila Department of Community Development File Number (A 6 - oa LE 9( LAND USE PERMIT ROUTING FORM TO: X Building ❑ Planning Parks/Rec Public Works Fire Dept. 0 Police Dept. ❑ Project: Address: c5t30 t-f- '_ 4 kQc S Date / transmitted: 7 1 kC. Response requested by: '1 (2t /\ C Staff �rZ_ tiu coordinator: 1 J 4� Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60-day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) Plan check date01C Comments prepared by: Update date: 0400 City of Tukwila Department of Community Development File Number C -occl LAND USE PERMIT ROUTING FORM TO: ❑ Building Parks/Rec 01 Planning Public Works Nr Fire Dept. �I Police Dept. 10 Project: )�` ` V iG g • Z.O N SE-L,I.; t vzz \ {.1 C_,c Address: `--S `-1 O Lfv-i4 4vE S Date transmitted: Q _ \ 7 AEC Response requested by: q 1721 �16 Staff coordinator: Date response received: �.5 4 X -.- REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60-day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director NOTICE OF COMPLETE APPLICATION September 7, 2016 Mr. Rick Cardoza Verizon Wireless, C/O LDC, Inc. 14201 NE 200th St. Woodinville, WA 98072 Subject: Verizon SEA Riverton Wireless Telecommunication Facility, 13130 44th Ave S, Tukwila, WA 98168 L16-0049, PL16-0041 Dear Mr. Cardoza, Your Wireless Telecommunication Facilities application for a Type 1 permit to make modifications to an existing wireless facility is considered complete on September 7, 2016 for the purposes of meeting state mandated time requirements. This determination of complete application does not preclude the ability of the City to require that you submit additional plans or information, if in our estimation such information is necessary to ensure the project meets the substantive requirements of the City or to complete the review process. This notice of complete application applies only to the permits identified above. It is your responsibility to apply for and obtain all necessary permits issued by other agencies. Please feel free to contact me with any questions at (206) 431-3683 or Maxwell.Baker@TukwilaWA.gov. Sincerely, Maxwell Baker Assistant Planner CITY OF TUKWILA Aim 5 2016 WIRELESS TELE- Department of Community Developmenr 6300 Southcenter Boulevard, Tukwila, WA aMthunity COMMUNICATION Telephone: (206) 431-3670 Development FACILITIES APPLICATION FOR STAFF USE ONLY Permits Plus Type: P-WIRE Planner: M bcx 1-30..File Number: (L, — Application Complete Date: R 7--, (t 6 Project File Number:/)/' / / „ ! CJC� .�` /�/ Application Incomplete Date: Other File Numbers: NAME OF PROJECT/DEVELOPMENT: Ikr tz,0 ( SE/4 J'i&'r 40 n BRIEF DESCRIPTION OF PROJECT: (DID qex. G'' 1 /e / 4 vt eA t /r e/ (A (_A °mil CIRCLE TYPE - /TYPE 11 TYPE 2 TYPE 3 Public hearing notices and Hearing Examiner fees apply LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. I-199174 27 ÷‘f- 41/e-- . LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent. Name: lQ /k a hoc t/eJi Z,f l Address: WO I G. w t /a- 2-040 0/1o6/ 4 !i/ (/e FAX: 7/41 c 2- Phone: E-mail: Signat Z�3 -2)8-q 1 tGarc1o�-� I . Date: el/Z-44-/ 1 \\deptstore\City Common \Teri \Kirby \July 28 2015\Wreless Communication Facility 06-04-15.docx CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY STATE OF WASHINGTON ss COUNTY OF KING The undersigned being duly sworn and upon oath states as follows: 1. I am the current owner of the property which is the subject of this application. 2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my knowledge. 3. The application is being submitted with my knowledge and consent. 4. Owner grants the City, its employees, a ent , ei�$ineers, contractors or other representatives the right to enter upon Owner's real property, located at `, 13 D '��7 /341/P. -C, for the purpose of application review, for the limited time necessary to complete that purpose„ 5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City. 6. Non -responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without refund of fees. EXECUTED at (Qi� Notary Public State of Washington RICHARD B CARDOIA My Appointment Expires Jul 1, 2019 (city), (Ja (state), on ,20 /(, _Shirt A.0 9Q (Print Name 7)a �,— (SEe"' �a�. SC/ ins R3) R'= r"/2 (Address} (Phone Number) 021.1.94f20-f (Signature) On this day personally appeared before me 5Ji (r[e L I.- 1" II €4 to me known to be the individual who executed the foregoing instrument and acknowledged that1ie/she signed the sarne as his/her voluntary act and deed for the uses and purposes mentioned therein. SUBSCRIBED AND SWORN TO BEFORE MEON THIS Z" DAY OF /40/4 A Oz2 NOTARY PUBLIC in and for the Stat of Wa hington residing at 5/(4.4t c ' �Ci t4 7 My Commission expires on "1 ` 6f% 20 (6 1\deptstore\City Conunon\Teri\KirbyUuly 28 20151Wirelcss Communication Facility 06.04-I5.docx LDC THE CIVIL ENGINEERING GROUP ( urn merc ijI Infra.lrutturr Re.idential August 24, 2016 City of Tukwila Department of Community Development 6300 Southcenter Boulevard Tukwila, WA 98188 RE: Verizon Communications Facility at 13130 44t" Avenue South site SEA Riverton — Type 1 WCF Dear Reviewer, Attached is a packet of information regarding the proposal by Verizon Wireless (VZW) to modify equipment on the existing tower located at 13130 44th Avenue S., at its existing Wireless Communications Facility (WCF) referred to as Verizon site SEA Riverton. The packet includes: 1. Completed Revised Application for WCF 2. 4 sets Construction Plans with site plans 3. Letter of Authorization from Verizon as land owner. 4. Type 1 fees Verizon proposes to replace 6 panel antennas on existing antenna mounts, replace 3 RRUs, remove 3 TMAs, add 6 RRUs, 9 A2s, 1 OVP, and 1 hybrid line on the existing tower with no ground disturbance. There will be no increase in height to the facility as a result of this proposal. As a result, this proposal is eligible as a 6409a project. If you have any questions or need more information regarding the requested revision, please email me at rcardoza@ldccorp.com or please call me at 253-218-9017. Rick Cardoza Representing Verizon Wireless www.LOCcorp.com fx: 425.482.2893 ph: 425.806.1869 Woodinville, WA 98072 14201 NE 200th Street, #100 Engineering the Standard COMPLETE APPLI ATION CHECKLIST The materials listed below must be submitted with your application unless specifically waived in writing the Department of Community Development. Please contact each Department if you feel that certain items are not applicable to your project and should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED. The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require additional information as needed to establish consistency with development standards. City staff are available to answer questions about application materials at 206-431-3670 (Department of Community Development) and 206-433-0179 (Department of Public Works). Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities. 1. Application Checklist (1 copy) indicating items submitted with application. 2. Completed Application Form and drawings (5 copies). n3 /'� 3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site map, architectural elevations, method of attachment, proposed screening, location of proposed antennas, and all other information which accurately depicts the proposed project. Minimum size is 8 1/2" x 11". Plans shall be no greater than 24" x 36". /H3 4. Application Fee: See Land Use Fee Schedule. 5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property , (1 copy attached). iV 6. SEPA Environmental Checklist. SEPA is not required when the facility: i) Is a microcell and is to be attached to an existing structure that is not a residence or school and does not contain a residence or a school; ii) Includes personal wireless antennas, other than a microcell, and is to be attached to an existing structure (that may be an existing tower) that is not a residence or school and does not contain a residence or school, and the existing structure to which it is to be attached is located in a commercial, industrial, manufacturing, forest or agriculture zone; or iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a commercial, industrial, manufacturing, forest, or as 'cultural zone. /43 7. A letter from the applicant describing the proposed project and describing compliance with the City's Code requirements. Include statement whether the proposal is considered a "substantial change" or not as defined by the FCC rules. .K3 8. Sensitive Area studies and proposed mitigation (if required). M 9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating compliance with TMC Chapter 8.22, "Noise". If the application requires a Type 2 review these additional items are needed: 10. Four sets of photo simulations that depict the existing and proposed view of the proposed facility; 11. Materials board for the screening material; 12. Landscaping plan; 13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal requirements for allowed emissions; 14. If the facility is located within a residential zone, a report from a radio frequency engineer explaining the need for the proposed wireless communication facility at that location. Additionally, the \\deptstore\City Common\Teri\Kirby\July 28 2015\Wireless Communication Facility 06-04-15.docx Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning applicant shall provide detailed discussion on why the wireless communication facility cannot be located within a commercial or industrial zone. If the application requires a Type 3 review these additional items are needed: 15. A narrative responding to the criteria at TMC Section 18.58.060. 16. The radio frequency engineer report shall include a discussion of the information required under TMC Section 18.58.070. The report shall also explain why a tower must be used instead of any of the other location options outlined in Table A. 17. Engineering Plans for the proposed tower. 18. A vicinity map depicting the proposed extent of the service area. 19. A graphic simulation showing the appearance of the proposed tower and ancillary structures and ancillary facilities from five points within the impacted vicinity. Such points are to be mutually agreed upon by the Director of DCD and applicant. All plans and photo simulations shall include the maximum build -out of the proposed facility. 20. Evidence of compliance with Federal Aviation Administration (FAA) standards for height and lighting and certificates of compliance from all affected agencies. 21. Evidence that the tower has been designed to meet the minimum structural standards for wireless communication facilities for a minimum of three providers of voice, video or data transmission services, including the applicant, and including a description of the number and types of antennas the tower can accommodate. PUBLIC NOTICE MATERIALS: 104 22. Payment of notice board fee (see Land Use Fee schedule) to FastSigns Tukwila OR provide a 4' x 4' public notice board on site within 14 days of the Department determining that a complete application has been received (see Public Notice Sign Specifications Handout). P �I500 f� 23. Pay the fee as established by the Land Use Fee Schedule for generating mailing labels; OR provide an excel spreadsheet of mailing labels for all property owners and tenants (residents and businesses) within feet of the subject property. Each unit in multiple family buildings e.g. apartments, condos, trailer parks --must be included. Once your project is assigned to a planner, you will be required to provide an electronic copy of the mailing label spreadsheet in the following format: Name, Street Address, City St Zip, with each of these fields as an individual column: Name Street Address City, St, Zip Mr. Smith 1234 Park Ave S Tukwila WA 98188 PLEASE NOTE: Regardless of whether you pay the City to generate the mailing labels or you provide them, there is an additional fee for postage and material as listed under Public Notice Mailing Fee on the Land Use Fee Schedule. Payment of this fee is due prior to issuance of the decision and you will receive a separate bill for this fee. 46 /A 24. If providing own labels, include King County Assessor's map(s) which shows the location of each property within 500 ft. of the subject lot. \\deptstore\City Common \ Teri \Kirby\July 28 2015\Wireless Communication Facility 06-04-15.docx nge\Construction\ 15 — SEA Riverton\D P2015\_Telecom\ 15— 643 • inp ..Glrnty E. ivoal 7.'PCII a. u;.m Y1h•1e 64V.0 P lil.nd myN•.: � . Snvc•os v ^� 'MS 13n+r• "'o! PROJECT F, Cg f (74•y fin ml A71rnn � r Ce San VICINITY MAP NOT TO SCALE DRIVING DIRECTIONS verizoW SEA RIVERTON 13130 44TH AVE S SEATTLE, WA 98168 ATC #: 83050 RIVERTON NeRAed a $ I abortm:t 'tth m *mein 1 v:N4�J4bncub : � a PROJECT b'<iW 144, a 16•441 h. Tacna OCo 403 3e..;e H. ye tNln: 1, eloo.l0Ml 11•H1 Sea114 BMAneMr11021„Il • o-. u Can -ale • I.C,r wn 4r, U 1i�r GENERAL LOCATION MAP NOT TO SCALE FROM VERIZON WIRELESS OFFICE: • HEAD SOUTHWEST ON SE EASTGATE WAY TOWARD SE EASTGATE WAY • TURN LEFT ONTO THE 1-90 W RAMP TO SEATTLE • KEEP LEFT, FOLLOW SIGNS FOR 1-90 W/SEATTLE AND MERGE ONTO 1-90 W • TAKE EXIT 10 FOR INTERSTATE 405 S TOWARD RENTON • MERGE ONTO I-405 S • TAKE THE INTERSTATE 5 N EXIT TOWARD SEATTLE • MERGE ONTO I-5 N • TAKE EXIT 156 FOR WA-599 N TOWARD TUKWILA • KEEP RIGHT, FOLLOW SIGNS FOR INTERURBAN AVENUE • TURN LEFT ONTO INTERURBAN AVE S • TURN LEFT ONTO S 133RD ST • TURN RIGHT ONTO 44TH PL S • TURN LEFT ONTO S 131ST ST • TURN RIGHT • DESTINATION WILL BE ON THE RIGHT APPROVAL / SIGN OFF APPROVED BY DATE SIGNATURE SITE ACQUISITION ZONING RF CONSTRUCTION MANAGER PROJECT MANAGER REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED A PROJECT CONTACT LIST APPLICANT: VERIZON WIRELESS 3245 158TH AVENUE SE, MS231 BELLEVUE, WA 98008 PROJECT ARCHITECT:: LDC, INC. 14201 NE 200TH ST, SUITE 100 WOODINVILLE, WA 98072 CONTACT: RICHARD B. HALL, AIA PHONE: (425) 806-1869 EMAIL: rhali@Idccorp.com PROPERTY OWNER: VERIZON WIRELESS 3245 158TH AVENUE SE, MS231 BELLEVUE, WA 98008 STRUCTURE OWNER: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA01801 PROJECT CONSULTANT: LDC, INC. 14201 NE 200TH ST, SUITE 100 WOODINVILLE, WA 98072 CONTACT: RICK CARDOZA PHONE: (253) 218-9017 EMAIL: rcardoza@ldccorp.com PROJECT INFORMATION CODE INFORMATION: ZONING CLASSIFICATION: BUILDING CODE: CONSTRUCTION TYPE: OCCUPANCY: CLI - COMMERCIAL LIGHT INDUSTRIAL SBC 2012 IIB U, S-2 JURISDICTION: CITY OF TUKWILA PROPOSED BUILDING USE: UNMANNED TELECOM SITE LOCATION (NAD83): LATITUDE: 47° 29' 10.14" N LONGITUDE: 122° 16' 42.74" W TOP OF STRUCTURE: 140.00'± AMSL BASE OF STRUCTURE: 20.00'± AMSL PROJECT LEASE AREA: N/A NEW IMPERVIOUS AREA: 0 SF (47.48615° N) (122.27854° W) 120.0' AGL 0.0' AGL PARCEL NUMBER: 7349200345 AREA OF PARCEL: 0.22 ACRES GENERAL INFORMATION: 1. PARKING REQUIREMENTS ARE UNCHANGED. 2. TRAFFIC IS UNAFFECTED. 3. SIGNAGE IS UNAFFECTED. PROJECT DESCRIPTION: VERIZON WIRELESS PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY WITH THE REPLACEMENT OF (6) PANEL ANTENNAS WITH THE REMOVAL OF (3) TMA'S, AND WITH THE ADDITION OF (3) RRUS 11 B13 WITH A2 UNITS, (3) RRUS 12 B2 A2 WITH UNITS, (1) OVP DISTRIBUTION BOX AND (1) HYBRID CABLE MOUNTED ON AN EXISTING MONOPOLE, AND (1) OVP DISTRIBUTION BOX (WITHIN EXISTING SHELTER) WITHIN AN EXISTING FENCED COMPOUND. DRAWING INDEX DWG NO. DESCRIPTION T-1.0 TITLE SHEET G-1.0 GENERAL NOTES A-1.0 SITE PLAN A-2.0 ENLARGED SITE PLAN A-3.0 ELEVATIONS A-4.0 CONSTRUCTION DETAILS A-5.0 CONSTRUCTION DETAILS RF-1.0 ANTENNA CONFIGURATION RF-2.0 ANTENNA CONFIGURATION DIAGRAM E-1.0 SCHEMATIC GROUNDING PLAN E-2.0 GROUNDING DETAILS LEGAL DESCRIPTION RIVERTON REPLAT LOTS 1 TO 5 LOTS 11 & 12 LY SWLY OF THE FOLG DESC LINE - BAAP OPPOSITE HWY ENGR STA 44+30 ON THE FA LINE SURVEY OF PRIMARY STATE HWY NO 1 SR 99 FOSTER INTERCHANGE TO S 118TH ST & 435 FT SWLY THEREON TH S 26-20-00 E 280 FT M/L TAP 30 FT NWLY WHEN MEAS RADIALLY FROM THE RELOC S 133RD ST C/L OF SAID HWY PLAN & THE END OF SD LN - TC017-1600 UTILITY COMPANIES POWER: SEATTLE CITY LIGHT PHONE: (206) 684-300 TELEPHONE: CENTURY LINK PHONE: (800) 777-9594 SCALE DISCLAIMER DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION. PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VERIZON WIRELESS SERVICES IS STRICTLY PROHIBITED. ATC SITE # 83050 RIVERTON 0 LDC chitectural Er gineering Structural THE CIVIL ENGIN66 NG GROUP Survey 14201 NE200th SI..#1W Ph. 425.806.1869 Woodlnvile, WA 98072 Fx. 425.4822893 _ _ _ _ www.LDCCOIP.corn _ I DATE: IDRAWN BY: CHECKED BY: 7-26-16 I RJG IRBH SUBM ITTALS REV DATE DESCRIPTION BY 1 7-2416 PREDMINARY CONSTRUCTION RBH 2 8-2-16 REVISED PRELIM CONSTRUCTION RBH 3 8-22-16 FINAL CONSTRUCTION RBH 8828 10 . ,V5-51 / 1 QTAIE OFWA!HPIGT0N SEATTtr EDPD APPROVAL STAMP ,c erg- 4 C E 4 -1 In Q. FA C1 Eo E SJ C.o - r,U0 — L-a SITE SEA RIVERTON 13130 44TH AVE S SEATTLE, WA 98168 SHEET TITLE TITLE SHEET SHEET NUMBER T-1.0 ABBREVIATIONS: i GENERAL NOTES: 1. THE PROPOSED INSTALLATION WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. 2. THE PROPOSED INSTALLATION IS UNMANNED AND IS NOT FOR HUMAN HABITATION (NO HANDICAP ACCESS IS REQUIRED) 3. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY VERIZON TECHNICIANS. 4. NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS PROPOSAL. 5. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED. 6. ALL REFERENCES TO SPECIFIC STANDARDS FOR THIS PROPOSAL ARE UNDERSTOOD TO BE THE LATEST VERSION. 7. THE TENDERED MUST UNDERGO A SITE VISIT TO CAREFULLY EXAMINE AND UNDERSTAND THE SCOPE OF THE WORK REQUIRED BEFORE BID SUBMISSION. NO COMPENSATION IN ANY FORM WILL BE PAID FOR EXPENSES RESULTING FROM FAILURE TO DO SO. 8. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CONSTRUCTION MANAGER. 9. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS, ELECTRICAL LINES, AND ANTENNA CABLES. 10. ROUTING OF ALL CONDUITS, CABLES, CABLE TRAYS, ETC. IS INDICATED AS PROPOSED LOCATIONS ONLY. CONFIRM THE EXACT ROUTING WITH THE ON -SITE CONSTRUCTION MANAGER PRIOR TO THE START OF WORK. 11. ALL DAMAGE OR OPENING UP OF THE EXISTING STRUCTURE MUST BE MADE GOOD TO THE PRE -CONSTRUCTION CONDITION OR BETTER. 12. INSPECTION OF COMPLETED WORK IS REQUIRED BEFORE COVERING UP. PROVIDE A MINIMUM OF 72 HOURS NOTICE TO CONSULTANT. 13. REMOVE AND CLEAN UP ANY DEBRIS OR MATERIAL FROM THE SITE THROUGHOUT THE DURATION OF THE CONTRACT ON A DAILY BASIS AND UPON COMPLETION OF THE WORK AS DIRECTED BY THE CONSTRUCTION MANAGER. 14. OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS AND INSPECTIONS REQUIRED FOR COMPLETION OF WORK AND ACCEPTANCE. PROVIDED CERTIFICATES TO THE CONSTRUCTION MANAGER VERIFYING THAT THE WORK CONFORMS TO THE REQUIREMENTS OF ALL CODES AND AUTHORITIES HAVING JURISDICTION. 15. PROVIDE VERIZON WITH A WRITTEN WARRANTY, EFFECTIVE FOR ONE YEAR AFTER DATE OF ACCEPTANCE. FOR THE COMPLETE INSTALLATION REPAIR OR REPLACE ANY DEFECTS ARISING DURING THIS PERIOD AT NO EXTRA COST TO VERIZON. 16. NO DEVIATIONS FROM DESIGN SHOWN ON THESE DRAWINGS IS ALLOWED WITHOUT WRITTEN APPROVAL FROM THE CONSULTANT. FAILURE TO OBSERVE THIS RULE MAY RESULT IN CONTRACTOR CORRECTING THE INSTALLATION AT THEIR EXPENSE. 17. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, REGULATIONS AND SAFETY REGULATIONS. ALL OSHA REGULATIONS, ALL PUBLIC AND MUNICIPAL AUTHORITIES, AND ANY UTILITY COMPANIES' REGULATIONS AND DIRECTIVES. 18. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OF WORK. EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THE CONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL DISCREPANCIES TO REPRESENTATIVE. ANY MINOR ERRORS AND OMISSIONS IN THE DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. 19. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS AND ELECTRICAL LINES AND ANTENNA MOUNTING. 20. VERIFICATION THAT EXISTING TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA, COAX AND ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. 21. ANTENNA AZIMUTHS SHOWN ON THESE DRAWINGS ARE BASED ON TRUE NORTH. ALL AZIMUTHS MUST BE VERIFIED WITH THE CORRECT SMR PRIOR TO CONSTRUCTION. LEGEND AND SYMBOLS: CHAIN LINK FENCE CEDAR FENCE POWER UNDERGROUND POWER TELCO UNDERGROUND TELCO OVERHEAD POWER BOUNDARY CENTERLINE REVISION BUG ELEVATION DETAIL NUMBER SHEET NUMBER UGT PROPOSED ELEVATION siv 0'-0" AGL A� If AFF AFG AFS ALUM AB L ARCH BTS BLDG BM BOT B.O. BOC BOS CJ CLG CLR CMU COL CONC CONST CONT CTR DIA/0 DTL (E) EA EJ ELEC EL EQ EW EXP EXT FD ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE FINISHED SLAB ALUMINUM ANCHOR BOLT ANGLE ARCHITECTURAL BASE TRANSMISSION SYSTEM BUILDING BEAM BOTTOM BOTTOM OF BOTTOM OF CONCRETE BOTTOM OF STEEL CONTROL JOINT CENTER LINE CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONSTRUCTION CONTINUOUS CENTER DIAMETER DETAIL EXISTING EACH EXPANSION JOINT ELECTRIC/ELECTRICAL ELEVATION EQUAL EACH WAY EXPANSION EXTERIOR FLOOR DRAIN FIN FINISH FIN FLR FINISH FLOOR FLR FLOOR FTG FOOTING GA GAUGE GALV GALVANIZED GYP GYPSUM GB GYPSUM BOARD HM HOLLOW METAL HOR HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING VENTILATION AIR CONDITIONING INSUL INSULATION INT INTERIOR JT LAM LF MANUF MAX MECH MH MM MIN MISC MPH MTL NIC NOM NTS OC OD OH OPNG OPP PCS SYSTEM PR PSI PSF PT RAD RD REINF REQ'D RM RAW SCHED SECT SF SIM SQ FT SS STD STL STRUC TEMP THK T.O. TOS TOC TYP UNO VERT W/ WWM JOINT LAMINATED LINEAL FOOT MANUFACTURER MAXIMUM MECHANICAL MANHOLE MILLIMETER MINIMUM MISCELLANEOUS MILES PER HOUR METAL NOT IN CONTRACT NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OVERHEAD OPENING OPPOSITE PERSONAL COMMUNICATION PLATE PAIR POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT PRESSURE TREATED RADIUS ROOF DRAIN REINFORCED/REINFORCING REQUIRED ROOM RIGHT OF WAY SCHEDULE SECTION SQUARE FOOT SIMILAR SQUARE FOOT STAINLESS STEEL STANDARD STEEL STRUCTURAL TEMPORARY THICK TOP OF TOP OF STEEL TOP OF CONCRETE TYPICAL UNLESS NOTED OTHERWISE VERTICAL WITH WELDED WIRE MESH Cal 2 &aleae Days Belore You Dig 0 LDC Architectural Engineering Structural TM CIVIL ENG INEEONC GEGUP Survey 14201 NE 2001h St., 8100 Ph. 425.806.1869 Woodinville, WA 98072 Fz 425.482.2893 www.LDCmtp.com - DATE: 7-26-16 DRAWN BY: RJG CHECKED BY: RBH SUBMITTALS REV DATE DESCRIPTION BY 1 7-26-16 PREUMINARY CONSTRUCTION RBH 2 8-2.16 REVISED PREUM CONSTRUCTION RBH 3 8-22-16 FINAL CONSTRUCTION RBH 8828 • • lTAIE OF WABXNG1CNN 11 SEATTLE DPD APPROVAL STAMP C,CS a LID n Q i t r � E O E 7315 Cr O O _,,. Ja r• SITE SEA RIVERTON 13130 44TH AVE S SEATTLE, WA 98168 SHEET TITLE GENERAL NOTES SHEET NUMBER SECTION BUG 1-800-424-5555 Utilities Underground Location Center GAONTANA,WASHIGTON) G-1.0 2016 — 2:37pm on\Drawings\Construction\ 15 ng: P:\2015\_Telecom\15-643 Verizon — SEA BC LD'NG \\7349200245 BU;Ii,NG ADJACENT ZONING: CLI - COMMERCIAL LIGHT INDUSTRIAL 2613200134 2613200133 SURVEY DISCLAIMER: PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN SETS OR FROM ASSESSORS MAPS. LDC HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIM AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. ADJACENT ZONING: CLI - COMMERCIAL LIGHT INDUSTRIAL EXISTING SITE ACCESS 7349200 I� I 99UH_DlNG 2613200087 S 133RD ST ZONING: CLI - COMMERCIAL LIGHT INDUSTRIAL 7349200345 ADJACENT ZONING: CLI - COMMERCIAL LIGHT INDUSTRIAL EXISTING VERIZON WIRELESS EQUIPMENT SHELTER WITHIN AN EXISTING FENCED COMPOUND PROPOSED VERIZON WIRELESS ANTENNA MOUNTED ON AN EXISTING 120.0' • MONOPOLE ADJACENT ZONING: CLI - COMMERCIAL LIGHT INDUSTRIAL 2613200006. SITE PLAN 1 0 tp. LDC Architectural Engineering Structural THE CIVIL ENGINEERING GtOUP Survey 14201 NE 200th St.,8100 PR 425.806.1869 Wmtlimile, WA 98072 Fx 425.482.2893 ww6.LDCmrp.com DATE: 7-26-16 DRAWN BY: RJG CHECKED BY: RBH SUBMITTALS REV DATE DESCRIPTION BY 1 7-26-16 PREUMINARY CONSTRUCTION RBH 2 8-246 REVISED PREUM CONSTRUCTION RBH 3 8-22-16 FINAL CONSTRUCTION RBH ea28 • QfA7EOFW011 4 SEATTLE.DPD APPROVAL STAMP I EL , N - N ( -3 c E O CM Oa = :3r i SITE SEA RIVERTON 13130 44TH AVE S SEATTLE, WA 98168 SHEET TITLE SITE PLAN SHEET NUMBER A-1.0 22"x34" SCALE: 1" = 20' I 11"x17" SCALE: 1" = 40' Ivy SEA Riverton \ 0 • • EXISTING BUILDING ETC\SS\NG FENCeO EXISTING OTHER CARRIER EQUIPMENT SHELTER \\ EXISTING OTHER CARRIER EQUIPMENT MOUNTED ON H-FRAME EXISTING OTHER CARRIER EQUIPMENT -- \ • vokosSs 44 9„ OVp10 EXISTING OTHER CARRIER GENERATOR -- r- 1ZON e REL S vauw I�1 \-\ BELOW ---EXISTING CMU WALL EXISTING ACCESS ROAD 73 O ENLARGED SITE PLAN 22"x34" SCALE: 1/4" = 1'-0" I 11"x17" SCALE: 1/8" =1 '-0" 1 CONSTRUCTION PLAN KEYED NOTES • EXISTING VERIZON WIRELESS EQUIPMENT SHELTER (TO REMAIN). 3 PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX MOUNTED TO MONOPOLE (1 TOTAL). O EXISTING 120.0' MONOPOLE (TO REMAIN). OEXISTING VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, 6 TOTAL TO REMAIN). O EXISTING VERIZON WIRELESS PLATFORM MOUNT (TO REMAIN). OEXISTING VERIZON WIRELESS RRUS UNIT (TYP 1 PER SECTOR, 3 TOTAL TO REMAIN). OPROPOSED VERIZON WIRELESS RRUS W/A2 UNIT 1 8 (TYP 2 PER SECTOR, 6 TOTAL). 0 9 EXISTING VERIZON WIRELESS 6'-0" HIGH CHAIN LINK FENCE (TO REMAIN). 10 EXISTING VERIZON WIRELESS CHAIN LINK ACCESS GATE, TYP (TO REMAIN). 12 PROPOSED VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, 6 TOTAL). 15 EXISTING VERIZON WIRELESS ICE BRIDGE / CABLE TRAY (TO REMAIN). PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX 19 MOUNTED WITHIN EXISTING SHELTER (IF WALL SPACE CANNOT ACCOMMODATE OVP BOX, GC SHALL PLACE BOX BETWEEN TWO WAVE GUIDE POSTS ADJACENT TO SHELTER (1 TOTAL). 1 PROPOSED VERIZON WIRELESS HYBRID CABLE TO ANTENNAS (1 TOTAL). SEE CABLE LENGTH SCHEDULE ON RF-1.0. OEXISTING VERIZON WIRELESS DIPLEXERS MOUNTED TO ANTENNA MOUNT (2 PER SECTOR, 6 TOTAL). O EXISTING VERIZON WIRELESS METER BASE (TO REMAIN). O 30 31 EXISTING VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX MOUNTED TO MONOPOLE (1 TOTAL TO REMAIN). EXISTING VERIZON WIRELESS HYBRID CABLE TO ANTENNAS (1 TOTAL TO REMAIN). EXISTING VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX MOUNTED WITHIN EXISTING SHELTER (1 TOTAL TO REMAIN). SITE NOTES 1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. 2. ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER. 3. PROPOSED ANTENNAS, EQUIPMENT AND MOUNTING HARDWARE NEAR ANTENNA LEVEL SHALL BE PAINTED TO MATCH EXISTING. ATC SITE # 83050 RIVERTON 0 4:1) LDC Architectural Engineering Structural TNECwu ENCINEEUNC GROUP Survey 14201 NE 2009181.. #100 Ph. 425.806.1869 Woodlnvile, WA 98072 FS. 425.482.2893 www.LDCcorp.cOm DATE: 7-26-16 DRAWN BY: CHECKED BY: RJG RBH SUBMITTALS REV DATE DESCRIPTION BY 1 7-26-16 PREUMINARY CONSTRUCTION RBH 2 8-2-16 REVISED PRELIM CONSTRUCTION RBH 3 8-22-16 FINAL CONSTRUCTION RBH 6a2a .4- tifA7E0FWA$HIOTON� 1/ , e SEATTLE DPD APPROVAL STAMP IL i'' w C is 1 N • N L i o E () cra O> 0r ^ Un SITE. SEA RIVERTON 13130 44TH AVE S SEATTLE, WA98168 SHEET TITLE ENLARGED SITE PLAN SHEET NUMBER A-2.0 Construction\ 15643CD—A3-0.d SEA Riverton \Dro P:\2015\_Telecom\15 TIP HEIGHT OF EXISTING VERIZON WIRELESS ANTENNAS iii,MOUNTED CONSTRUCTION PLAN KEYED NOTES NOTE: UPGRADE/REPLACE STANDARD PIPE(S) AS NEEDED PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX AI TIP HEIGHT OF EXISTING VERIZON WIRELESS ANTENNAS ' 121.8' AGL " TIP HEIGHT OF PROPOSED VERIZON WIRELESS ANTENNAS O TO MONOPOLE (1 TOTAL). NUCF 4O EXISTING 120.0' MONOPOLE (TO REMAIN). 5 EXISTING VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, NY 6 TOTAL TO REMAIN). 0.EXISTING VERIZON WIRELESS PLATFORM MOUNT (TO REMAIN). EXISTING VERIZON WIRELESS RRUS UNIT (TYP 1 PER SECTOR, 3 O TOTAL TO REMAIN). PROPOSED VERIZON WIRELESS RRUS W/ A2 UNIT 121.1' AGL TIP HEIGHT OF EXISTING VERIZON ON WIRELESS ANTENNAS 121.2'AGL TIP HEIGHT OF EXISTING Q VERIZON WIRELESS ANTENNAS © TIP HEIGHT OF EXISTING VERIZON WIRELESS ANTENNAS • ` 121.1' AGL TIP HEIGHT OF EXISTING Imm i TOP OF EXISTING MONOPOLE •• 120.8' AGL TOP OF EXISTING . MONOPOLE d VERIZON WIRELESS ANTENNAS b 1 hi' � (I 120 .0'AGL $ 0 O(_ O / EXISTING OTHER CARRIER ANTENNA ARRAY (TO REMAIN) -- \ O EXISTING OTHER CARRIER ANTENNA ARRAY (TO REMAIN) -- �l{!� EXISTING OTHER CARRIER EQUIPMENT MOUNTED TO H-FRAME \ EXISTING OTHER EXISTING CARRIER SHELTER \ CMU WALL - \ \\ \ L d �. I �"; Id8 I I �I I 1, I, it �. A l `d :�) _ u �) , ' � Ih Id �! Y 120.0'AGL Y ® BEHIND 4> 1EXISTING j 1 A b I r---EXISTING OTHER ' CARRIER EQUIPMENT I ` 120.2' AGL 0 O O4 EXISTING OTHER CARRIER ANTENNA ARRAY (TO REMAIN) - O '' t XISTING OTHER CARRIER ANTENNA ARRAY (TO REMAIN) \\.:1 EXISTING OTHER CARRIER EQUIPMENT MOUNTED TO H-FRAME --� EXISTING OTHER EXISTING CARRIER SHELTER —\ \ CMU WALL - \ [ f ' —LLL ___ p, Li y ,', I e �tt!^! , U IS..._ (� ti,i .�_ . ! r j i, _d = I 1 L,i f © Li r EXISTING OTHER I CARRIER EQUIPMENT / 8 (TYP 2 PER SECTOR, 6 TOTAL). EXISTING VERIZON WIRELESS 6'-0" HIGH CHAIN LINK FENCE 9 (TO REMAIN). VERIZON WIRELESS CHAIN LINK ACCESS GATE, TYP 10 (TO REMAIN). 12 PROPOSED VERIZON WIRELESS PANEL ANTENNA � 2 2 (TYP 2 PER SECTOR, 6 TOTAL). I EXISTING VERIZON WIRELESS TMA MOUNTED TO EXISTING 13 ANTENNA MOUNT (TYP 1 PER SECTOR, 3 TOTAL TO BE REPLACED). 18 EXISTING VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, 6 TOTAL TO BE REPLACED). Q EXISTING VERIZON WIRELESS DIPLEXERS MOUNTED TO ANTENNA MOUNT (2 PER SECTOR, 6 TOTAL). EXISTING VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX MOUNTED TO MONOPOLE (1 TOTAL TO REMAIN). 1 , SITE NOTES .. 1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. 2.ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED B Y l OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER. ! . i 3. PROPOSED ANTENNAS, EQUIPMENT AND MOUNTING HARDWARE NEAR ANTENNA LEVEL SHALL BE PAINTED TO MATCH EXISTING. I 1 1 FINISH GRADE ,, , ,_ _ = �' v,. sy `x �� 1 \ FINISH GRADE „ _ . t c 1 J¢ _ f -, ,-y 0.0' AGL EXISTING VERIZON WIRELESS 52' 6" 0.0' AGL EXISTING VERIZON WIRELESS 52'�" e 9 FENCED COMPOUND 9 FENCED COMPOUND PROPOSED SOUTHWEST ELEVATION (LOOKING NE) 2 EXISTING SOUTHWEST ELEVATION (LOOKING NE) 1 1 22"x34" SCALE: 1/8" = 1'-0" I 11"x17" SCALE: 1/16" = 1'-0" 22"x34" SCALE: 1/8" = 1'-0" 11"x17" SCALE: 1/16" = 1'-0" 0 LDC Engi Struural ctural THECrva ENGINEERING CROUP Survey 14201 NE 200th SL, 4100 Ph. 425.806.1869 Woodinville. WA 98072 Fx. 425.482.2893 — www.LDCcorp.com DATE: 7-26-16 DRAWN BY: RJG CHECKED BY: RBH SUBMITTALS REV DATE DESCRIPTION BY 1 7-26-16 PREUMINARY CONSTRUCTION RBH 2 8-246 REVISED PRELIM CONSTRUCTION RBH 3 8-2246 FINAL CONSTRUCTION RBH 8828 I. OF WASHING10 N1 4 SEATTLE,©PD APPROVAL STAMP 1 - yii CCP _ O Q cC c ' N �c E t: 1 :c m c U r, I SITE SEA RIVERTON 13130 44TH AVE S SEATTLE, WA 90168 1 SHEET TITLE ELEVATIONS SHEET NUMBER A-3.0 ngs\Construction\ 15643CD—A4 SEA Riverton\Dr ing: P:\2015\_Telecom\15-6 NO HIGH STRENGTH BOLTING IS PROPOSED OR SHALL BE USED. RAYCAP DISTRIBUTION OVP BOX RAYCAP DISTRIBUTION OVP BOX MOUNTING BRACKET FIXED RETAINER EXTRUSION SLIDING RETAINER EXTRUSION CARRIAGE BOLT TOP SIDE MANUFACTURER: RAYCAP MODEL: RCMDC-3315-PF-48 WEIGHT: 21.5 LBS DIMENSIONS: 25.66"x 19.18"x 15.73" strikesorb modules installed to protect 6 remote radio heads 22"x34" SCALE: N.T.S. NOT USED 2 11"x17" SCALE: N.T.S. RAYCAP DISTRIBUTION OVP BOX 13 22"x34" SCALE: 1" = 1'-0" I 11"x17" SCALE: 1/2" = 1'-0" NO HIGH STRENGTH BOLTING IS PROPOSED OR SHALL BE USED. ERICSSON RRUS 12 OR RRUS B13 ANTENNA MOUNTING PIPE 90° ALUMINIUM ANGLE SIZE AS PER MANUF. SPEC. (2) REQUIRED M12x35 LG STAINLESS BOLT c/w (2) LOW NUT, (2) LOCK NUT & (2) WASHER (4) ASSEMBLIES REQUIRED ALUMINIUM MOUNT (2) REQUIRED M10x200 LG STAINLESS BOLT c/w (3) NUTS & (2) WASHER (2) ASSEMBLIES REQUIRED ALUMINIUM CLAMP FRONT ALUMINIUM CLAMP BACK MOUNTING BOLT (4) REQUIRED REFER TO MANUF. SPEC. RRUS A2 UNIT w MANUFACTURER: ERICSSON MODEL: RRUS B13 WEIGHT: 51 LBS DIMENSIONS: 19.7"X17"X7.2" MOUNTING KIT: MOUNTING KIT PROVIDED 00 0000 00000 ► I 00000�1 0000�: 0000E? 00000 : 00000►; 00000�; 00000►i 00000 00000►; 0 00 00 . 000.�• 00•c.0 000: 00 00 0000 000000 000000 000000 000000 000000 000000 000000 '0,00000 00'0000 730 0000,0 �'00000 0000 000".� 000� 00 0 4V MANUFACTURER: ERICSSON MODEL: RRUS 12 WEIGHT: 58 LBS DIMENSIONS: 20.4"X16.4"X7.5" MOUNTING KIT: MOUNTING KIT PROVIDED 00 0000 000001 000001 0000�' 0000i' 000001 000001 000001 00000' 000001 00000► 0000::() 0. 000."• 00•c.0 000: 0 7 00 0000 000000 000000 000000 000000 000000 000000 000000 '0,00000 0 00.00 0 760 00 000 ‚'0000- 0'.1000 000'.'.0 000". 00 MANUFACTURER: ERICSSON MODEL: RRUS A2 (MOUNTED TO RRUS 12 OR RRUS B13) WEIGHT: 22 LBS DIMENSIONS: 16.4"X15.1"X3.4" MOUNTING KIT: MOUNTING KIT PROVIDED NOT USED 22"x34" SCALE: N.T.S. 11"x17" SCALE: N.T.S. 2 RRUS & A2 UNIT DETAIL 22"x34" SCALE: N.T.S. 11"x17" SCALE: N.T.S. 1 ATC SITE # 83050 RIVE 0 .i LDC Architectural Engineering Structural ENE MIL ENGINEERING GROUP Survey 14201 NE 200111 01., e100 Ph. 425.805.1869 Woodinville, WA 98072 Fx. 425.482.2893 - — - www.LOCcorp•com DATE: 7-26-16 IDRAWN BY: CHECKED BY: RJG RBH SUBMITTALS REV DATE DESCRIPTION BY 1 7-26-16 PRELIMINARY CONSTRUCTION RBH 2 8-2-16 REVISED PRELIM CONSTRUCTION RBH 3 8-22-16 FINAL CONSTRUCTION RBH 8626 11.• iVxgi .iii, / VrAlE OF W Mo7ON ' ,1e SEATTLE DPD APPROVAL STAMP N c m � 0 44 crr > SHEET TITLE CONSTRUCTION DETAILS SHEET NUMBER A-4.0 ngs\Construction\ 15643CD—A5-0. — SEA Riverton \Dr NOT USED 6 NOT USED 5 NOT USED 4 I 22"x34" SCALE: N.T.S. I 11"x17" SCALE: N.T.S. I 22"x34" SCALE: N.T.S. I 11"x17" SCALE: N.T.S. I 22"x34" SCALE: N.T.S. I 11"x17" SCALE: N.T.S. 15.6" 7.4" PARTS. WEIGHT: 115 LBS ♦ DIMENSIONS: 91.7"x15.6"x7.4" FREQUENCY: REFER TOSMR SHEET ♦ s -i a j ITEM QTY DESCRIPTION 15.6" 0 0 Qt 1 ADAPTER, POLE, LOWER 0 0 O Q2 1 BRACKET, DOWNTILT, POLE i� Q3 1 BRACKET, DOWNTILT, ANTENNA 0 �i\. �4 © ® 6 1/2 X 1 HEX HEAD BOLD 06 1/2 SPLINT WASHER a.` k I © 2 5/16 X 1 HEX HEAD BOLT ploartgo " Q 2 5/16 SPLIT WASHER .1'. � OPTIONAL DOWNTILT ® 4 1/2" THREADED ROD A" © BRACKET p 8 1/2" SPLIT WASHER 0 12 1/2" NUT AP .1110 ill r0 �`� 0 �r PANEL ANTENNA (TYP) } NOTES i� v TOP�. sort♦ 0 PIPE MOUNT TYP) 1. INSERT SCISSOR BRACKETS BETWEEN THE UPPER WI VALMONT T (TYP)LECT ANTENNA MOUNTING BRACKET AND THE UPPER PARTL#NT MI01 RR POLE ADAPTER BRACKET. SECURE USING 1/2 INCH HARDWARE PROVIDED. APPROVED EQUAL 2. TO SET THE DEGREE OF DOWNTILT, ALIGN THE DESIRED HOLES ON THE SCISSOR BRACKETS AND SECURE USING 5/16 INCH HARDWARE PROVIDED. TH ANUENNMBE OFTYCONNECTORS WILL VARY BASED ONE. ♦ FRONT SIDE NOT USED 3 ANTENNA SPECIFICATIONS 2 ANTENNA MOUNTING DETAIL 1 I 22"x34" SCALE: 3/4" = 1'-0" I 11"x17" SCALE: 3/8" = 1'-0" I 22"x34" SCALE: 1" = 1'-0" I 11"x17" SCALE: 1/2" = 1'-0" I 22"x34" SCALE: N.T.S. I 11"x17" SCALE: N.T.S. 0 'i LDC Architectural THE CIVIL ENCINUM. CROUP Survey 14201 NE 200th St..9100 Ph. 425.806.1869 Woodilwlle, WA 98072 Fc 425.4822893 _ .._ www.Lpeosip.com DATE: 7-26-16 DRAWN BY: RJG CHECKED BY: RBH SUBM ITTALS REV DATE DESCRIPTION BY 7-26-16 PRELIMINARY CONSTRUCTION RBH 2 8-2-16 REVISED PREUM CONSTRUCTION RBH 3 8-22-16 FINALCONSTRUCT10N RBH SEATTLE DPD APPROVAL STAMP CE E o O SITE SEA RIVERTON 13130 44TH AVE S SEATTLE, WA98168 SHEET TITLE CONSTRUCTION DETAILS SHEET NUMBER A-5.0 2016 — 2:39pm . ge\Construction\ 15643CD—RF1-0.dwg SEA Riverton\Dr P:\2015\_telecom\15-643 • EXISTING MONOPOLE (TO REMAIN) PROPOSED ANTENNA CONFIGURATION SECTOR ANTENNA QUANTITY AZIMUTH TECH TIP HEIGHT ANTENNA SIZE MECH. TILT COAX PER ANTENNA COAX COAX LENGTH 1 1 346° 850 CDMA 121.1' 96.0" 1° 2 1-5/8" 132' 1 346° PCS CDMA 121.2' 98.3" 3° 2 1-5/8" 132' 1 346° 700 AWS 121.8' 98.3" 0° 1 HYBRID 132' 1 346° 700 PCS 120.2' 75.0" 0° 1 HYBRID 132' SECTOR ANTENNA QUANTITY AZIMUTH TECH TIP HEIGHT ANTENNA SIZE MECH. TILT COAX PER ANTENNA COAX O COAX LENGTH 2 1 106° 850 CDMA 121.1' 96.0" 1° 2 1-5/8" 132' 1 106° PCS CDMA 121.2' 98.3" 3° 2 1-5/8" 132' 1 106° 700 AWS 121.8' 98.3" 0° 0 HYBRID 1 106° 700 PCS 120.2' 75.0" 0° 0 HYBRID SECTOR ANTENNA QUANTITY AZIMUTH TECH TIP HEIGHT ANTENNA SIZE MECH. TILT COAX PER ANTENNA COAX 000AX LENGTH 3 1 226° 850 CDMA 121.1' 96.0" 0° 2 1-5/8" 132' 1 226° PCS CDMA 121.2' 98.3" 0° 2 1-5/8" 132' 1 226° 700 AWS 121.8' 98.3" 0° 0 HYBRID 1 226° 700 PCS 122.1' 75.0" 0° 0 HYBRID TASK SUBMITTED ON: 07/21/16 2 HYBRID 132' NOTE: • OTHER CARRIER ANTENNA ARRAY(S) NOT SHOWN FOR CLARITY • UPGRADE/REPLACE STANDARD PIPE(S) AS NEEDED • ADD (1) HYBRID INTEGRATED FIBER AND POWER CABLE(S) TO FEED THE REMOTE RADIO HEAD(S). ONE HYBRID CABLE IS ABOUT 1.5" IN DIAMETER 850 CDMA 700 PCS 700 AWS EXISTING VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX MOUNTED TO MONOPOLE (1 TOTAL TO REMAIN) PCS CDMA PCS CDMA EXISTING VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, 6 TOTAL TO REMAIN) 700 AWS 850 CDMA EXISTING VERIZON WIRELESS RRUS UNIT (TYP 1 PER SECTOR, 3 TOTAL TO REMAIN) (BELOW) 700 ,--PROPOSED VERIZON WIRELESS PCS RRUS W/ A2 UNIT (TYP 2 PER SECTOR, 6 TOTAL) 850 CDMA EXISTING VERIZON WIRELESS DIPLEXERS MOUNTED TO ANTENNA MOUNT (2 PER SECTOR, 6 TOTAL) PCS CDMA PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX MOUNTED TO MONOPOLE (1 TOTAL) 700 AWS 700 PCS EXISTING VERIZON WIRELESS PLATFORM MOUNT (TO REMAIN) PROPOSED VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, 6 TOTAL) EXISTING ANTENNA CONFIGURATION SECTOR ANTENNA QUANTITY AZIMUTH TECH TIP HEIGHT ANTENNA SIZE MECH. TILT COAX PER ANTENNA COAX 0 COAX LENGTH 1 1 346° 850 CDMA 121.1' 96.0" 1° 2 1-5/8" 132' 1 346° PCS DO 120.8' 75.0" 0° 0 HYBRID 1 346° AWS LTE 120.8' 75.0" 0° 1 HYBRID 132' 1 346° 700 LTE 121.0' 94.68" 3° 2 1-5/8" 132' SECTOR ANTENNA QUANTITY AZIMUTH TECH TIP HEIGHT ANTENNA SIZE MECH. TILT COAX PER ANTENNA COAX O COAX LENGTH 2 1 106° 850 CDMA 121.1' 96.0" 1° 2 1-5/8" 132' 1 106° PCS DO 120.8' 75.0" 0° 0 HYBRID 1 106° AWS LTE 120.8' 75.0" 0° 0 HYBRID 1 106° 700 LTE 121.0' 94.68" 3° 2 1-5/8" 132' SECTOR ANTENNA QUANTITY AZIMUTH TECH TIP HEIGHT ANTENNA SIZE MECH. TILT COAX PER ANTENNA COAX 000AX LENGTH 3 1 226° 850 CDMA 121.1' 96.0" 1° 2 1-5/8" 132' 1 226° PCS DO 120.8' 75.0" 0° 0 HYBRID 1 226° AWS LTE 120.8' 75.0" 0° 0 HYBRID 1 226° 700 LTE 121.0' 94.68" 3° 2 1-5/8" 132' TASK SUBMITTED ON: 07/21/16 1 HYBRID 132' EXISTING MONOPOLE (TO REMAIN) 850 CDMA 700 LTE AWS LTE EXISTING VERIZON WIRELESS RAYCAP EXISTING VERIZON WIRELESS TMA MOUNTED TO EXISTING ANTENNA MOUNT (TYP 1 PER SECTOR, 3 TOTAL TO BE REPLACED) PCS DO EXISTING VERIZON WIRELESS RRUS UNIT (TYP 1 PER SECTOR, 3 TOTAL TO REMAIN) AWS LTE 700 LTE DISTRIBUTION OVP BOX MOUNTED TO MONOPOLE (1 TOTAL TO REMAIN) PCS DO \St‘ / 850 CDMA 850 CDMA EXISTING VERIZON WIRELESS DIPLEXERS MOUNTED TO ANTENNA MOUNT (2 PER SECTOR, 6 TOTAL) PCS DO AWS LTE �(, 700 LTE 44 EXISTING VERIZON WIRELESS PLATFORM MOUNT (TO REMAIN) EXISTING VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, 6 TOTAL TO BE REPLACED) EXISTING VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, 6 TOTAL TO REMAIN) PROPOSED ANTENNA CONFIGURATION 22"x34" SCALE: 1/2" = 1'-0" I 11"x17" SCALE: 1/4" = 1'-0" 2 EXISTING ANTENNA CONFIGURATION I 22"x34" SCALE: 1/2" = 1'-0" I 11"x17" SCALE: 1/4" = 1'-0" 1 ATC SITE # 83050 RIVERTON 0 .L LDC Architectural Engineering Structural THE ova ENGINmaw came Survey 14201 NE-200th St., 4100 Ph. 425.806.1869 Woodinville. WA 98072 Fx. 425.4822893 1w.LDC80rp.co.6 I DATE: DRAWN BY: CHECKED BY: 7-26-16 RJG RBH SUBMITTALS REV DATE DESCRIPTION BY 1 7-2646 PRELIMINARY CONSTRUCTION RBH 2 8-2-16 REVISED PRELIM CONSTRUCTION RBH 3 8-22-16 FINAL CONSTRUCTION RBH 8828 /• • SPATE OF WMIMOTON JP SEATTE-DPD APPROVAL STAMP L N -- 5 1~ SITE SEA RIVERTON 13130 44TH AVE S SEATTLE, WA 98168 SHEET TITLE ANTENNA CONFIGURATION SHEET NUMBER RF-1.0 gs\Construction\ 1 5643C on — SEA Riverton\Dr P:\2015\_Telecom\ 15— 6 550 1.1 Hz pcs cDr A x x x x x x x x x uuuuUO • I DIPLEXER II DIR.DER I ■ • DIP(EXER I DIPL'ER I • SECTOR 1 aWI . A2 ■ ■ P1 Rana 815 C- r1 x x x x x x x x x x x x ULf uu u.a ,.1111 RRI S02 A2 850 MHz %PM x x uu PCS CDMA 9(-P x x x x x x x x x tfnuuu H ▪ • • i I DPLDER 11 D1PLEXER I RIVETON 6-20-2016 SECTOR 2 f—AVM Q(•POL x x x x x x x x x x x x Oo00D .. MI RROSM . A2 1 OVP-6 I DREXER • r'. n el n es el /1 n DIPLEXER I n n n 61 xxxx xxxx xxxx bQuboo 006 711 Da RRUO 02 �A2-° IT I S50 P.1rz •PC . x x PCS CDMLA 9(•POL x x x x x x x x x u uuuuuu I DIPLEJ<ER 11 pPLEXER ti I DIPLEXER J I gPLEXER 1 OVP-6 SECTOR 3 A(•POL x x x x x x x x x x x x art, L' IA a OVP-6 *MOL x x x x x x x x x x x x ANTENNA CONFIGURATION DIAGRAM I i 0 LDC Architectural Engineering Structural THECIVIFENGINFE[INC CROW. SUIVey 14201 NE 2001h St., 4100 Ph. 426 806.1869 Woodinville. WA 98072 F,c 426.482.2893 www.LDCTnrp.cam DATE: 7-26-16 DRAWN BY: CHECKED BY: RJG RBH SUBMITTALS REV DATE DESCRIPTION BY 1 7-26.16 PRELIMINARY CONSTRUCTION RBH 2 8-2-16 REVISED PRELIM CONSTRUCTOR RBH 3 8-22-16 FINAL CONSTRUCTION RBH 8828 / • \ 6TAaE OfWMRNOfo1111 4 SEATTLE DPD'APP OVAI:BTAMP .. N f•, >n 1 F SITE SEA RIVERTON 13130 44TH AVE S SEATTLE, WA 98168 SHEET TITLE ANTENNA CONFIGURATION DIAGRAM TC SITE # SHEET NUMBER RF-2.0 2016- 2:41pm P:\2015\_Telecom\15-643 Veri:an - SEA .44 • " • I -�. • GROUNDING KEYED NOTES O EXISTING GROUND RING AT BASE OF MONOPOLE (FIELD VERIFY). O EXISTING MGB AT BASE OF MONOPOLE. O EXISTING AGB AT ANTENNAS. O EXISTING AGB CONNECTED TO MGB WITH (2) #2 BTCW. O PROPOSED VERIZON ANTENNA PER PLAN, TYP. OEXISTING MONOPOLE. Ark GENERAL GROUNDING NOTES 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. ANY METAL OBJECTS WITHIN 6 FEET OF THE EXTERNAL GROUND RING SHALL BE GROUNDED. 3. ALL GROUND CONNECTIONS SHALL BE CADWELD AND CLEANED THOROUGHLY THEN COVERED WITH TWO (2) COATS OF SHERWIN WILLIAMS GALVANTE PAINT B350W3 OR EQUAL. SEE 1/E-2.0 FOR TYPICAL CONNECTIONS. 4. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 3. ALL ELECTRICAL CADWELD AND MECHANICAL CONNECTIONS SHALL HAVE NON -OXIDATION COMPOUND APPLIED TO CONNECTION. 4. ALL MATERIALS AND CADWELD MOLDS, SHOTS, ETC. SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR UNLESS OTHERWISE NOTED. 5. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 6. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. 7. USE PANI SCHEME FOR LOADING GROUNDS ON MGB AS DISCUSSED IN NSTD 119, 33 & 36. GROUNDING LEGEND • • • GROUND BAR GROUND INSPECTION WELL COPPER GROUND ROD COMPRESSION LUG CADWELD CONNECTION SIDE SPLICE CADWELD FIELD VERIFY & TIE INTO EXISTING GROUNDING SYSTEM SCHEMATIC ANTENNA GROUNDING PLAN 22"x34" SCALE: 1 /2" = 1'-0" I 11"x17" SCALE: 1/4" = 1'-0" 1 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VERIZON SERVICES ARE STRICTLY PROHIBITED. ATC SITE # 83050 RIVERTON 0 .i LDC Architectural Engineering Structural THE 058 ENCINEEUNCCtOUP Survey 14201 NE 2000Sl.,0180 Ph 425.806.1869 Woodinville, WA 98072 Fx 4254822893 �— - WNVI.LDCCofp.0 m I DATE: 7-26-16 DRAWN BY: RJG CHECKED BY: RBH SUBMITTALS REV DATE DESCRIPTION BY 1 7-26-16 PRELIMINARY CONSTRUCTION RBH 2 8-2.16 REVISED PRELIM CONSTRUCTION RBH 3 8-22-16 FINAL CONSTRUCTION RBH 4 tf� • erAreawA!HINGTONN SEATTLE DPD APPROVAL STAMP (��' F4 —,,G Cam' O 4` O ¢,,," a L-+1 VA o Ur `SITE F • SEA RIVERTON 13130 44TH AVE S SEATTLE, WA 98168 SHEET TITLE SCHEMATIC GROUNDING PLAN SHEET NUMBER E-1.0 2016 — 2:41pm SEA Riverton\Drawings\Construction \15 GROUND ISOLATOR (TYP AT EACH O GROUND BAR) n NEW COAXIAL GROUND KITS W/LONG BARREL COMPRESSION DOUBLE LUGS, ATTACH TO GROUND BAR & INSTALL BY ANTENNA CONTRACTOR (CADWELD TYPE-GL) `NEW 4"x24"x1BAR/4 THK COPPERINSTALLEDBY GROUND !1/ GENERAL CONTRACTOR O n STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION. SIZE AS SPECIFIED TYPICALLY 12" TO 24" COPPER GROUND BAR ON WALL, ICE BRIDGE, FLOOR OR ON ANTENNA TOWER .e ",o N.." .e two., .o ANTENNA CABLE 2 1/2" 0 MAX 120" MAX O O o 0000 0000 OOO Q O O O o O 0000 0 O 0 0 O O g b O O O 000000000000 000000000 0 O O O 0 0 0 0 0 0 0 0 0 0 d \ \ J WEATHERPROOFING KIT (SEE NOTE 3) CABLE CABLE GROUND KIT CONNECTOR #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO1AND GROUND2 BAR). SEE NOTE NOTES NOTE TWO HOLE TO GROUND 3/8"-16x1/4" STEEL AND HARDWARE `TWO HOLE SOLID TINNED CU WIRE INSULATION BUILDING LUG, BOLTED BAR USING STAINLESS HEX HEAD BOLTS- LUG, TO BE USED BARE CU WIRE WITH GREEN, 600V, TO ANTENNA RING GROUND OR �/ J WITH #2 AWG OR STRANDED THHWTHWN STRUCTURE, MGB I I l 26" MGB OR 6" ANTENNAAGB Q NOTE FIELD VERIFY #2 SOLID BARE TINNED COPPER WIRE CADWELD (TYPE-GL) 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH TWO HOLE LUG. 3. WEATHERPROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. GROUND BARS AT BOTTOM OF TOWERS/MONOPOLES SHALL USE EXOTHERMIC CONNECTION. COAT ALL MECHANICAL CONNECTIONS WITH "NOOX" OR APPROVED EQUAL. GROUND BAR 6 GROUND BAR CONNECTION 5 CABLE GROUNDING DETAIL 4 I 22"x34" SCALE: 2" = 1'-0" I 11"x17" SCALE: 1" = 1'-0" I 22"x34" SCALE: 1" = 1'-0" I 11"x17" SCALE: 1/2" = 1'-0" 22"x34" SCALE: 3/16" = 1'-0" I 11"x17" SCALE: 3/32" = 1'-0" TO RX2 JUMPER REQUIRED ONLY FOR 1-5/8"0 COAX OR FOR EASE OF CONNECTION (TYP) CONNECTOR ANTENNAS TX1/RX1 WEATHERPROOFING KIT (TYP) STANDARD GROUND 0 KIT (TYP) SEE NOTE. WEATHERPROOFING KIT (TYP) SEE NOTE 2 ANTENNA CABLE TO BTS EQUIPMENT (TYP) ` #6 AWG ANTENNA GROUND BAR, SIMILAR TO K16-057. MOUNT GROUND BAR NEAR TOP OF I ' I SELF SUPPORT TOWER, TOWER OR WAVEGUIDE LADDER NOTES \-#2 AWG STRANDED INSULATED BONDED TO TOWER STEEL OR SELF SUPPORT TOWER 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHERPROOFING SHALL BE ANDREWS. (TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.) ANTENNA GROUND BAR 3 NOT USED 2 NOT USED 1 1 I 22"x34" SCALE: N.T.S. I 11"x17" SCALE: N.T.S. I 22"x34" SCALE: 1 1/2" = 1'-0" I 11"x17" SCALE: 3/4" = 1'-0" I 22"x34" SCALE: N.T.S. I 11"x17" SCALE: N.T.S. 0 't 6 LDC Architectural Engineering Structural THE CIVIL ENGINEERING GROUP Survey 14201 NE 20018 St, 8100 Ph. 425.800.1869 Woodinville. WA 98072 Fx. 425.482.2893 www.LDCcolp.com DATE: 7-26-16 DRAWN BY: RJG CHECKED BY: RBH SUBM ITTALS REV DATE DESCRIPTION BY 1 7-26-16 PRELIMINARY CONSTRUCTION RBH 2 8-2-16 REVISED PRELIM CONSTRUCTION RBH 3 8-2246 FINALCONSTRUCTION RBH 882a REGISTERED ARCHRECT • • ` TATEOFWM1110nroxy y �� �141 SEATTLE DPD / R}2OVAL VAMP C ��Q tll c", E 1 ci E jCl co so 0 SITE SEA RIVERTON 13130 44TH AVE S SEATTLE, WA 98168 SHEET TITLE GROUNDING DETAILS SHEET NUMBER E-2.0