Loading...
HomeMy WebLinkAboutPermit S18-0007 - COUNTRY FINANCIAL - BUILDING MOUNTED SIGNCOUNTRY FINANCIAL 16400 SOUTHCENTER PKWY #310 S18-0007 BUILDING MOUNTED SIGN City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Parcel No: 2623049021 Address: PERMANENT SIGN PERMIT Permit Number: 518-0007 16400 SOUTHCENTER PKWY 310 Issue Date: 2/8/2018 Permit Expires On: 8/7/2018 Owner: Name: RADOVICH PROPERTIES LLC Address: 2835 82ND AVE SE STE S 1, MERCER ISLAND, WA, 98040 Contact Person: Name: ISAAC DUKE Phone: (360) 259-2178 Address: 3435 MARTIN WAY, STE H , OLYMPIA, WA, 98506 Contractor: Name: BLAZE ELECTRIC & SVCS CO INC Phone: Address: 209 125TH ST S , TACOMA, WA, 98444 License No: BLAZEE5010P8 Expiration Date: Business: Name: COUNTRY FINANCIAL 16400 SOUTHCENTER PKWY #310, TUKWILA, WA Address: DESCRIPTION OF WORK: ONE BUILDING MOUNTED SIGN FOR COUNTRY FINANCIAL Fees Collected: $279.03 Zoning: TUC -RC Electricity Provided by: PUGET SOUND ENERGY Types of Sign: 1. BUILDING -WALL EXPOSED BUILDING FACE: SIGN AREA (SQ FT): Planning Division Authorized Signature: 3849.99 58.22 e. 4 eiarnd- Date: 2/8/18 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Signature: Print Name: ACCEPTANCE BY EMAIL IS SIGNATURE FOR PERMIT AND CONDITIONS Date: 2/8/18 THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. SIGN INSPECTION (PLANNING) File No. S18-0007 Name of Tenant: Country Financial Sign Address: 17651 Southcenter Parkway Date Photo Taken: July 19th, 2018 X Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of XX/XX/200X Make new site visit and take photo by XX/XX/200X Comments: Sign appears to conform to approved permit. DR Sign permit inspections are conducted once a month. This allows approximately 30 days for the sign to be manufactured and installed. Please let us know if more time is needed. If payment for the job is pending final inspection approval, please provide the sign permit information by email to jaclyn.adams@tukwilawa.gov or call 206-431-3670 and we will complete the inspection within five (5) business days. Electrical permits and inspections occur independent of this permit. FINAL INSPECTION APPROVAL: DATE: CITY OF TUKWILA Department of Community Development 6300 Soulhcenter Boulevard, Tulovila, WA 98188 Telephone: (206) 431-3670 PERMANENT SIGNS Building Mounted And Freestanding PERMANENT SIGN PERMIT APPLICATION FOR STAFF USE ONLY Planner : File Number : \ CC - Q no --4- Needs Electrical : Yes / No Associated File Numbers : Zoning of Site: CommerciaUlndustrial Residential Number of Building Mounted Signs included in application: 1 Number of Freestanding/Monument Signs included in application: 0 Other signs included in application (Dynamic / Canopy /Awning / Other): nia Text on sign will read: COUNTRY FINANCIAL Name of Tenant: Country Financial Address of Tenant / Business: 16400 Southcenter Pkwy, Tukwila, WA 98188 5v) lo Contractor: BLAZE ELECTRIC & SRVC CO INC Contractor State License #: BLAZEES010P8 Contractor's City of Tukwila Business License #: Contractor Address: 209 125Th St S city Taco Contact Name for Permit: Isaac Duke Y3 a st WA zip 98444 Contact Address: 3435 Martin Way E, Ste H city Olympia st WA zip 98506 Contact E-mail: IsaacD@NWSignSource.com Contact Phone: (360) 259-2178 I HEREBY CERTIFY that the information contained in this application and the materials furnished to the City by me are true. I understand that if I provide incorrect information on this application or submit plans that are not correct it could inuRce a permit or, if the permit has been ed, e cause for the City to revoke the sign permit: •-• - 1-25-18 Date: JAN 2,0 2019 Signature af awner or Authorized Agent rl'r unity De,,e)prner.t PARCEL INFO Parcel: 262304-9021 Zone: TUC -RC (Tukwila Urban Center) Parcel Area: 1.95 Acres Structure Area: 66,955 Sq. Ft, Structure Height: 64' Floors: 5 Year Built: 1979 Property Owner: RADOVIC- PROPERTIES LLC 2835 82ND AVE SE STE S-1 MERCER ISLAND, WA 98040 VICINITY MAP Country Financial • Tukwila 16400 Southcenter Parkway -J%\ Tukwila, VVA 98188 DATE: 1-25.18 DESIGN: Country Financial Tukwila PERMIT DRAWINGS TA L. S \SORC- LL, ATE). CO v 1RC AL IsaacD@NWSicnSource.com (360) 259-2178 JANNiul, SHEET1 corrupt, C vellieeet & Site Map Scale: 1" = 50' On? , A Illuminated Cabinet • Green Install new illuminated cabinet flush to fascia. NOTE: Electrical access thru drop ceiling, 3/16" #7328 white acrylic 3M#3630-126 Emerald Green 1s1 surface — retainer & cabinet painted to match 3M#3630-126 Emerald Green r COUNTRY itil" retainers FINANCIAL® A B CFA .GR.48 41-014,6 11J16" C D sf 177/8 1 7 /16" ! 58.2 WO Typo' Celan ccier $11110141rOilti Country Financial • Tukwila 16400 Southcenter Parkway Tukwila, WA 98188 DATE: 145.18 DESIGN: Country Financial Tukwila PERMIT DRAWINGS survey measuremen Exposed Building Face: 60'-0" L x 64'-2" = 3,850 sq. ft. Permitted Sign Area: (EBF-3,000) x .02 + 110 sq. ft. (3,850-3,000) x .02 + 110 sq. ft, 850 x.02 + 110 17 + 110 Permitted Sign Area: 127 sq. ft. Actual Proposed Sign Area: 58.23 sq. ft. Sign Weight: 100 lbs. Sign Wattage: 240 watts 'ETA L. LLYI\ATED.CO"PCIA_ saacD@NWSignSource,com (360) 259-2178_ cor,i,n,„ sH E ET 2 Elevations and Sign Specs Scale: 114" = LOGO CA3ENET P' aluminum angle re .125' aluminum returns welded to back 3/16' white polycarbonate face electrical bushing Supply wire 1225' aluminum backs welded to returns LED module 1/4" dia. weep holes with light cover returns weld to back Country Financial Tukwila 16400 Southcenter Parkway Tukwila, WA 98188 DATE: 1.25.18 DESIGN: Country Financial Tukwila PERMIT DRAWIN Power Supply Housing Lk Listed weatherproof toggle disconnect '— 3/81 flexible conduit (min.) 3/8" dia. concrete anchor 2 min embed ..---Junction Box Primary lectrical source WSDGNSORC ;ETA L° _L iv ATE) . CO v RCIA saacD@NWSignSource.com (360) 259-2178 �'' �� �•�� SHEET3 Side View and Details Scale: N.T.S.