HomeMy WebLinkAboutPermit EL19-0085 - WESTFIELD SOUTHCENTER MALL / RESTROOM UPGRADE - NEW LIGHTING, HAND DRYER CIRCUITS AND EMERGENCY CALL BOXESWESTFIELD RESTROOM UPGRADE 2800 SOUTHCENTER MALL ELI 9-0085 Parcel No: Address: 0 City txx of Tukwila Deportment of Community Development 63V0SouthcenterBoulevard, Suite #1Vn Tukwila, Washington 9M1Q8 Phone:Z86'431'367O Inspection Request Line: 3O6'438'93S0 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 9203470010 Permit Number: EL19'0085 Project Name: WESTFIELD RESTROOM UPGRADE Issue Date: 3/7/2019 Permit Expires On: 9/3/2019 Owner: Address: Contact Person: Name: Address: WESTFIELD PROPERTY TAX DEPT POBOX l3O94O'[ARiSBAO WA, 92013 5HANE]0HN90N 30214045TE,E4TONV|LLE WA, 98328 Contractor: Name: STATIC ELECTRIC INC Address: 3OZl4O4THSTE'EATONV|LLE,WA, 98328 License No: STATIEI951C8 Lender. Name: Address ''' Phone: (253)468-3296 Expiration Date:Z/2s/2OZ1 DESCRIPTION VFWORK: NEW LIGHTING, HAND DRYER CIRCUITS AND EMERGENCY CALL BOXES FOR MEN'S AND WOMEN'S RESTROD&4S|N CENTER OFMALL. lSTFLOOR Valuation cfsingle family: $0.00 Valuation ofmf/cnnnnn: $60,000.00 Type nfWork: REMODEL Fees Collected: $1,477.91 Electrical ServicePmvidedby-` PUG ET- SOUND ENERGY VVater0sthct: TUKVV|LA SewerDisthct: TUKVV|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: international Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VV4[29646B: y Code: Permit Center Authorized Signature: Date: (q I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agreq to the conditions attached to this permit. Signatur Date: 3 _ 7 -1 9 Print Name: S'\ 2 Ash <cA-` This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector, 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. ,�_. �1 9 - 00 Project No. C, Date Application Accepted: 0 / 1 -' I/ Date Application Expires: 0 7 7?-6 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: P0 Sot,'tl<tcewEer Ir(i ( PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON - person receiving all project communication Name: � c, *r t.� \ IA" .Svc-• Address: -302 t Li 0‘)1/4p,�� City: r-�t�Vt iC State: L}A. Zip: 9r3Z Phone: 2G1.4-L{t,s, ---iz 1bFax: Email: v,-t \ l"" c‘r..fx ` e teal, I C . 6 � Z King Co Assessor's Tax No.: Suite Number: gestf ee.-o--S Floor: New Tenant: Yes No ELECTRICAL CONTRACTOR INFORMATION Company Name: S �i J e G k , c c t Address: 3 g Z 1 4 0 4 4,- s. . City: kyk V t `l State: 1 A 1A -- Zip: Phone: 2s3 _Litx_ . z56 Fax: Contr Reg No.: sT 1_ �Z A; j c,Exp Date: 2 _Z 5 _ 2 i Tukwila Business License No.: ov U 6 _i S) G Valuation of Project (contractor's bid price): $ (oO ) ot,c . GG Scope of Work (please provide detailed information): NI e k A e e!-Se h1l r?G1(PS c S -� c c �-� S f `;\ C P "1-ct r C42 1,-,1-05 tinCJ dr1 - rnerS QC IAKx en r^&l) s�— C'"/Cc— /� ,t^cVt IV Will service be altered? EJ Yes No Type of Use: (-d P1 lx / tc t Re Ske'I' C Type of work: ❑ New ❑ Low Voltage Property Served bv: uget Sound Energy ❑ Addition ❑ Generator ❑ Service Change ❑ Fire Alarm ❑ SSattle City Light Adding more than 50 amps? ( Yes CINo leRemodel El Tenant Improvement ❑ Telecommunication ❑ Temporary Service W:\Pemtit Center\Applications-Handouts\Permit Applications \PDF's\Electrical Permit Application Revised 1-17-19.docx Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $180.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $120.00 ea ❑ Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $120.00 (no added/altered circuits) ❑ Service change with added/altered circuits $100.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $60.00 (up to 5 circuits) ❑ Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea ❑ Meter/mast repair $80.00 ❑ Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $90.00 ❑ Manufactured/mobile home service $100.00 (excluding garage or outbuilding) ❑ Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: 51na,--, t_ Aobrt 5,— Mailing Address: 3 &7 1 `i G S r Date: ( `.-`- Day Telephone: as-)—Lia-3 - 0'1 el kir111e_ k' 4 / Z g City State Zip W:\Pemut Center Applications-Handouts\Permit Applications\PDFs\Electrical Permit Application Revised 1-17-19.docx Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1186.85 EL19-0085 Address: 2800 SOUTHCENTER MALL Apn: 92024700 0 $1,186.85 ELECTRICAL $1,130.33 PERMIT FEE MU T -FAM/COMM R000 322.101.00.00 0,00 $1430,33 TECHNOLOGY FEE $56.52 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17 02 R000 322,900.04.00 0,00 $56.52 $1,186.85 Date Paid: Thursday, March 07, 2019 Paid By: STATIC ELECTRIC INC Pay Method: CHECK 2139 Printed: Thursday, March 07, 2019 9:15 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $291.06 EL19-0085 Address: 2800 SOUTHCENTER MALL Apn: 3597000150 $291.06 Credit Card Fee $8.48 Credit Card Fee R000.369,908.00.00 0.00 .1111001 ELECTRICAL $282.58 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R16672 R000.345.832.00.00 0.00 11111MBEI $291.06 Date Paid: Monday, January 28, 2019 Paid By: STATIC ELECTRIC Pay Method: CREDIT CARD 041919 Printed: Monday, January 28, 2019 4:20 PM 1 of 1 YSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 01/28/2019 04:19:33 PM CREDIT CARD SALE VISA CARD NUMBER: **********0565 K TRAN AMOUNT: $291.06 APPROVAL CD: 041919 RECORD #: 000 CLERK ID: Laurie Thank you! Customer Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO, PE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit inspection Request Line (206) 438-9350 Project: (Ai ccsr-Fta, Type of Inspection: miliA-t---- Address: 00 '©ate Called: Special Instructions: Date Wanted:7 {' Requester: Phone No: Approved per applicable codes. 11 Corrections required prior to approval. OMMENTS: Inspector: Date: 12(0 REINSPECT I€IN FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPE TION NO. INSPECTION RECORD Retain a copy with permit T O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Project: Type nspe on: Address: Date Called: Special Instructions. Date'Wanted: a. • . • Requester: Phone No: proved per applicable codes. E Corrections required prior to approval. ns pet or: Date: 0 REINSPEcTION FEE REQUIRED. Prior to next inspection, fee nust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.. #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Project:_ Type of Inspection: ACV 14 f�tA Address: ©0 -Date Called: Special Instructions: Date Wanted: �. a.m. Requester: Phone No: ����) .� �� C71-9 riApproved per applicable codes. Corrections required prior to approval. CO MENTS: Inspector; it/z4, (1 7 Date: 0 REINSPECTIOJ FEE REQUIRED. Prior to next inspection. fee mu t be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector; it/z4, (1 7 Date: 0 REINSPECTIOJ FEE REQUIRED. Prior to next inspection. fee mu t be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Proje : - . I Type of Insiiection: Address: ,. .. Date Called: Special instructions: Date Wanted: Requester: 'Phone No: 243 6 C, 572.-/-/ DApproved per applicable codes. LJCorrections required prior to approval. COMMENTS: nspector. Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fe&must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF- TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 E T Project: Type of lnspec on: Add e : ate C lied: Special Instructions: 1 Date Wanted: a. .pJfl. Requester: Phone No: riApproved per applicable codes. Corrections required prior to approva COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY.° PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0085 DATE: 01/28/19 PROJECT NAME: WESTFIELD RESTROOM UPGRADE SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: 16' 1BTiIding Divisio Public Works Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 01/29/19 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie. Zoning Issues) DUE DATE: 02/26/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg E] Fire 11 Ping LJ PW Staff Initials: 12/18/2013 Hone Search L Safety & Health Claims & Insurance Ck Washington State Department of Labor & Industries A-`Z..Index. Help Workplace Rights Trades & Licensing STATIC ELECTRIC INC Owner or tradesperson Principals JOHNSON, SHANE E, PRESIDENT JOHNSON, SHANE E, AGENT Doing business as STATIC ELECTRIC INC WA UBI No. 602 455 807 3021 404th St E EATONVILLE, WA 98328 253-468-3296 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. STATIE1951C8 Effective — expiration 02/25/2005— 02/25/2021 Designated administrator JOHNSON, SHANE License type Electrical Administrator Bond Wesco Insurance Co Bond account no. 46-WB075720 Received by L&I 05/06/2016 Bond history Savirags No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. License no. JOHNSS*973PH $4,000.00 Effective date 05/04/2016 Expiration date Until Canceled Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiu L&I Account ID Account is current. 131,984-01 Doing business as Help us improve tor:, N STATIC ELECTRIC INC Estimated workers reported Quarter 4 of Year 2018 "4 to 6 Workers" L&I account contact T2 / LINDA ALGUIRE (360)902-4678 - Email: P0TH235©Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 01/20/2017 Inspection no. 317943430 Location 20811 84 Ave, S. Kent, WA 98032 Violations i Washington State Dept of Labor & Industries. Use of this site is subject to the laws of the state of VVashiRgton. Help us improve LIGHTING FIXTURE SCHEDULE ELECTRICAL SYMBOLS LEGEND 18-086 - E10.dwg 08/27/18- 11:59am TYPE A AX B2 B3 CX MANUFACTURER LAMPS PRUDENTIAL P9222LED35SOWAJBSCUNVXI ND SAME AS TYPE A WITH EMH OPTION FOCAL POINT FCOLHS1000LF35K1 CUNIVLDI CVZ SAME AS TYPE B2 IN 4'-0" OPTION SAME AS TYPE Cl WITH EM AND LC4EM OPTIONS LED LED LED LED LED PART 1 - GENERAL 1.01 GENERAL CONDITIONS A. Bidding documents including Division 1 General Conditions, Supplementary General Conditions, Published Addenda and related work in other Divisions form an integral part of these Specifications and shall be binding on the Contractor for all work performed. 1.02 DEFINITIONS A. The term "provide" shall mean furnish, install and connect equipment and materials complete in operating condition. B. The term "approved" as used herein shall mean the written approval of the Engineer. C. The term "Contractor" as used herein shall mean the organization responsible for accomplishing all work within the contract documents. The plural term "contractors" as used herein shall include all of the trade organizations that comprise the project workforce. D. The term "drawings" as used herein shall mean all contract drawings. E. NEC means National Electrical Code. F. The term "code" as used herein shall mean all applicable National, State and local codes. 1.03 SCOPE OF WORK A. The work consists of furnishing, installing, testing and placing in satisfactory operation all equipment, materials, devices and appurtenances, necessary to provide complete systems according to the intent of the Drawings and Specifications. In general this includes all labor, materials, equipment, tools, etc. to complete the work. B. The project consists of re -configuring the existing electrical distribution system to allow new equipment to be installed. Existing electrical equipment not to be retained shall be removed and cleaned up to make the space useable. C. All materials shall be new, free from defects, of the quality specified herein and on the drawings. Materials shall be designed to insure satisfactory operation and rated life in the prevailing environmental conditions where they are being installed. They shall be listed by Underwriter's Laboratories or a recognized testing laboratory for use under these conditions. D. Each type of material shall be of the same make and quality throughout the job. The materials furnished shall be the latest standard design products of manufacturers regularly engaged in their production. 1.04 INTENT OF DRAWINGS A. The drawings are intended to serve as working drawings for general layout. Equipment, receptacles, lights, telephone/data outlets and raceways are partially diagrammatic and do not necessarily indicate actual routings or all appurtenances required for a complete installation. B. The drawings and specifications are complementary. What is called for in either is binding as if called for in both. In case of conflict within the drawings, specifications or between drawings and specifications the Architect/Engineer will select the method to be taken. C. Take all working dimensions from field measurements. In the event of conflict, report discrepancies to the Architect/Engineer for resolution before proceeding with the work. D. Minor changes in the locations of raceways, devices and the like, from those shown on the plans, shall be made without extra charge if so directed by the Architect/Engineer/Owner before installation. E. All systems specified herein and shown on the drawings shall be complete and operational in every detail. Mention of certain materials in bidding documents shall not be construed as releasing the Contractor from furnishing such additional materials and performing all labor required to provide a complete and operable system. 1.05 MANUFACTURERS' RECOMMENDATIONS A. Make all installations in strict accordance with manufacturers' published recommendations and details. All equipment and materials recommended by them shall be considered as part of this contract. 1.06 SUPERVISION AND COORDINATION A. Contact Electrical Inspection and obtain permit before starting work. B. Maintain adequate supervision of the work and have a responsible person in charge at the site any time work is in progress or when necessary for coordination with other trades. C. Schedule work to best serve the interests of the Owner. The building will be fully occupied by the owner during construction. Cooperate with other contractors on the job and coordinate work to avoid interference with them. D. Determine a satisfactory space allocation arrangement where electrical material is installed in proximity to work of other trades. No extra payments will be allowed to relocate work that interferes with that of other trades. WATTS 32 32 27 36 45 TYPE MANUFACTURER LAMPS El E2 EXISTING STRIP FIXTURE E3 E4 EXISTING LAY -IN FIXTURE 1.07 CODES AND REGULATIONS EXISTING STRIP FIXTURE MOUNTED VERTICALLY ACRYLIC LAY IN LENSE EXISTING DOWN LIGHT METAL HALIDE (1)F32T8 (1)F32T8 (1)35W MH (2)F18T8 WATTS 37 37 45 36 A. All work shall conform to current applicable National, State and local Building Energy, Fire Alarm, ADA and Electrical Codes. These codes shall be regarded as the minimum standard of quality for material and workmanship. B. Contractor shall provide all Labor and Material required for compliance with Code Requirements or Code Interpretations, although not specifically detailed on the Drawings or in the Specifications. C. Nothing in these Drawings and Specifications shall be construed as permitting work not conforming with governing codes. D. The Contractor shall not be relieved from complying with any requirements of these contract documents which may exceed, but not conflict with, requirements of the governing codes. 1.08 PERMITS & FEES A. Obtain and pay all fees for licenses, permits and inspections required by laws, ordinances and rules governing work specified herein. Arrange for inspection of work and provide inspectors with all necessary assistance. 1.09 SUBMITTALS A. Contractor shall provide electronic PDF electrical submittals demonstrating the Contractor's understanding of the intent of the design. Submittal shall include conduit, conductors, and light fixtures. 1.10 WORKMANSHIP A. All work shall be done by competent craftsmen skilled in the specific work to be done. Equipment shall be installed in a neat and workmanlike manner following the best practice of the trade. 1.11 AS -BUILT RECORD DRAWINGS A. Continuously maintain a set of As -Built Drawings to indicate all significant deviations from the original design and the actual placement of equipment and conduits. Localion of surface conduit runs shall be dimensioned from accepted reference lines. Changes shall be shown with red colored pencil while work is in progress. This "As -Built" set shall be clearly marked: "AS -BUILT RECORD DRAWINGS - Do Not Remove From Job." B. Final "As -Built" prints shall be prepared by a competent drafter on a clean set of blueline drawings. Date, firm name, and drafter's name shall be included with title "CORRECTED AS -BUILT" on each drawing. If there are no changes, drawing shall be marked "NO CHANGES, INSTALLATION PER PLAN." C. "As -Built Record Drawings" and "Corrected to As -Built" prints shall be delivered to the Architect/Engineer for transmittal to the Owner. 1.12 FINAL INSPECTION A. The electrical foreman or superintendent shall accompany the Owner and Architect/Engineer on the Final Inspection, and on any necessary Post -Final Inspections, to confirm all work has been satisfactorily completed. B. Defects and deficiencies found during this Final Inspection shall be corrected within 15 days of Contractor's receipt of Architect/Engineer final punch list. 1.13 GUARANTEE A. The Contractor shall provide written guarantee to repair or replace (without additional expense) any defective materials or workmanship which become evident within a period of one (1) year after final acceptance or for such longer period as elsewhere specified. All warranty work shall be to the satisfaction of the Owner. END OF SECTION 16000 0 17 SP 41) 0 STRIP FIXTURE MOUNTED VERTICALLY. DOWNLIGHT FIXTURE. CEILING GRID MOUNTED LIGHT FIXTURE. AUDIO SPEAKER. ADA FIRE ALARM SPEAKER, CEILING MOUNTED. JUNCTION BOX. DUPLEX RECEPTACLE 20A, 125 VOLT WALL MOUNTED AT 18 INCHES AFF. G = GROUND FAULT INTERRUPTING. SMOKE DETECTOR REVISIONS No changes snail be made to the scope of work without prior approval of the Tukwila Building Division. NOTE: Revisions ncl dwill e additional plan review. submittal and may FlLE�V P��� Permit No. Plan review approval is subject to errors and omissions Approval of construction documents does not auth.. nze the violation of any adopted code or ordinance Receipt of approved Field Copy and nditions isrrjowledgea: Date: 3 — 1 — City of TuKwiia BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED FEB 251019/ City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN282019 PERMIT CENTER CROSS ENGINEERS, INC 923 MLK Jr. Way Tacoma, WA 98405 info@crossengineers.com Phone: (253) 759-0118 • Job Number: 18-086 ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com LEVEL ONE RESTROOM UPGRADE SOUTHCENTER MALL Z O 0 z CONSULTANT SEPARATE PERMIT R IRED FOR: Mechanical ❑ Electrical [_/ Plumbing 1J Gas Piping City of Tukwila BUILDING DIVISION STAMP REVISIONS: PHASE / DELIVERABLE 60% APPROVAL SET DATE: DRAWN: PROJECT NO: APPROVED: SHEET TITLE: GENERAL NOTES/ FIXTURE SCHEDULE/ SPECIFICATIONS SHEET NO: 8/30/2018 JAE 18-086 SLW/SLH Interior Lighting - Space-By-S .aceMethod LTG-INT-SPACE! 201E Waehlnpton State Energy Code Compliance Form for Corranerolel Mild! rcpr Inaludnp R$ R3, P4 over 3 ator and all R1 Retired Auptot 2018 ProJect Title; Westfield t uths°nter Raetrearrfe-alone Date 8/27/2019 Calculation Area r°' Q Q Milian - O Addition stand alone+ +PAsting Q Spaces where < 60% of Q Spices where k 30% of Q luminaires era repined luminaires era replaced For Building Department Uee LPA Calculation Type • Standard 0 Additional Efficiency Package option Q C406.3 Reduced Interior Lighting To comply With C40R3, the Propand LPD nisi] be 25% biker than the Target LPA. Peferto C408.3 for additional raqulrementa. Maximum Allowed ]Lighting WatN°' Location (plan #, room #) Space Type Ceiling 1-ielghtN7E2 eroee hterica Area In ft' Allowed Watts per h' Watts Allowed (wattaift' x area) Sheet E3,0 Corridor: al other 361 0.530 191 Sheet E3.0 Restroom; lull other 546 0.780 426 Lobby Art/Exhibit Display Allowance horn LTG-Wt t316PLAY N2712 Total Area Retell DisplayAlowsnoe 907 LTG-INT-DISPLAY Allowed Watts from 618 Proposed Lighting Wattage 14rrr:3 Loceticn(plan#, room 0) Fixture Deacrptkat4'54'5'a Number of Fixtures Welts/ FixtureN::4En Watts Proposed Corridor Type A 3 32 96 Corridor Type AX 4 32 128 Restroom Type E2 1 27 2 7 Restroom Type B3 7 36 253 Restroom Type C1X 2 45 90 Proposed Retail Map Tetm1 Proposed Wetta meynot exceed Total Aflemed Wails for interior Lighting ay Lighting from LTG-INT-DISPLAY Total Proposed Watts 593 Interior Lighting Power Allowance COMPLIES Nate 1- List iN unique apace types per Table C405.4.2(2) !hat **curl, the project acrrpe. Select apace type category per from drop dove; maaru. Note 2 - indicate oohing height !br atriums end spline frtll/zThg he cull/ng height eciustmentper Table C405.4.2(2), Footnotes d lieu f, Note 3 - list ell proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed fixture Description, indicate Mara type, lamp type (e.g. T 8), numberoi temps in the fixture, and baf/est type (if included). For took fighting, !lathe length of the track(7n MOM addition to the fixture, Damp, andbelleet Infbrmeion. Note 5 -For fighting equipment eligrole for exemption per C405,41.1, note exception number end leave Wattr/Flxiireblank. No E„ iettngd mein &twos shell be Included In the Proonssd Lighting Wattage table in the same runner se new fixtures. Ilan* se existing in fixture description. Note 7 - For proposed WsttelFixture enter the luminaire scsitega for lnstetsd /amp end West using menuiecturer or other approved source. For voltage luminaires tooth sar9W-in lamps, enter the manufacturer's Babel maximum input ROW of the fl0t0. (not the limp ego). Far low fighting, !Martha swans of the tnansftanter. Forums votive trackibusvley systems, enter the larger of the attached luminslre xsettege or 50 xrsits/1/neel foot or enter the wettegi limit of permanent °arrant limiting clavicle. Nate 8 - Lobby A,tiExhiblt DlspfeyAftoWenoe Is independent cif the Maximum Allowed Lifphtkrg Wattage. Note 9 - Calculation Area Details: e. Lighting fixtures hi a building addit on mayat;?mply as as stand clone project, or they may be combined with the overall existing building lighting systems to demonstrate sompffance, Refertca C502.1. 08/27/18-11:57am interior Lighting - Space -By -Space Method LTG-INT-SPACE 2018 WauhIngton State Energy Code Compilerroe Forme for Commerolei IBuikiln{ir Inoludnp R2, R3, R4 over 3 stories and all R1 Project Title: Westfield Southoenter Rsstroome-Women, Date 8/27/2011 Calculation Area N°n:r Q Q Addition - 0 Addition stand alone + existing Q Spaces where < MS of Q Spaces, where k 60% of ea Iuminalrea are replaced luminaires are replaced Q For Bulking Department Use LPA Calculation Type • Standard Q Additional Efficiency Package option Q C406.3 Reduced Interior Uahtmg To comply swth C405.3, the Proposed LPD shall be 25% tosser then the Target LPA. Refer to C4083for additional requirements. Maximum Allowed Lighting Wattage NMI Location (plan #, room 0) $pace Type Ceiling 1-lelghtNorE2 otoea trawler Area In R' Allowed Watts per ha Watts Allowed (watte/h' x area) Sheet E3.0 Corridor: al other 207 0.53 0 110 Sheet E3.0 Restroom: all other 461 0.780 360 LobbyAA/Exhibit Display Allowance from LTG-IVT-I0I5PLAY^ s Total Area Retal Display 669 LTG-INT-DISPLAY Allowed Watts A owenoe from 470 Proposed Lighting Wattage N'T3 Location (plan 0, room 0) Flxtu'eDescriptionNo�4'5' Number of Fixtures Watts/ FlxhxeNcar57 Watts Proposed Corridor TypeA 2 32 64 Corridor TypeAX 1 32 32 Restroom Type 132 2 27 59 Restroom TA* B3 7 36 252 Restroom Type C1X 1 45 45 Proposed Retell DisplayLighting from LTG-INT-DISPLAY Teti Proposed Web meynot exceed Total Aiioxed Welts far interior Lighting Total Proposed Watts 447 Interior Lighting Power Allowance COMPLIES Nate 1- Lief all unique apace types per Tibia C405,4.2(2) that occur In the project aoope, Select apace type category per farm, drop down menu Note 2 - indicate oelling height ler strlum2 end apnoea tithing the ceding height acgushment per Table C405.4.2(2), Footnotes d lieu f Note 3 - List ell proposed fighting ifxturea including exempt fighting equipment and existing-todemeln fixtures, Note 4 - Forprapoaed Fixture Descrapt on, indicate fixture type, lamp type (e.g. T-8), numberof lamps in the fixture, and ballast type (lf Matudad), For track lighting, fist the length of the track an feet) in addition to the fixture, lamp, and ballast lnlormafion. Note 5 - Feu fighting equipment eigble for exemption per C405, 4. f, note exception number end leave Watts/Fixture blank. Note ii - E MUM -lanai r; llxturea shag! be Included in the Proposed What; Wattage table In the sane manner as new fixtures. Identify se in fixture description. Nate 7 - Fnrpropossd Wefts/Fixture enter the krmkoaire Wattage for instated tamp end bmileat using rharnrfacturer or other approved source. Far luminaires lath scressoM lamps, enter the menufeaturere listed maximum Input taettage of the fixture (not the limp seettage). For low voleige 50 wettedlineei Note 8 - Lobby AnYExhiblt Dlepley Allowance le indepor enter the mange limit ofendent limitingnent current of the MaximummMowed LightMg Wattage Note 8 - Calculation Area Dotes: a. Llghthrg fixtures In a building sc'd t n may comply era a stand alone project, or they maybe combined with the overall existing bufding lighting systems to demonstrate compliance. Refer to C502.1. lighting, enter the wettatye of the transformer. For fine voltage track/tummy systems, enter the lam of the attached iuminaire wattage or REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 201Q, City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN282019 PERMIT CENTER CROSS ENGINEERS, INC 923 MLK Jr. Way Tacoma, WA 98405 info@crosseng i neers.com Phone: (253) 759-0118 Job Number: 18-086 ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com W z J Z � � z ODw Q > 0 (-2 in 0 i-- -1 Ct (f)o= w CONSULTANT STAMP REVISIONS: PHASE / DELIVERABLE 60% APPROVAL SET DATE: DRAWN: PROJECT NO: 8/30/2018 JAE 18-086 APPROVED: SLW/SLH SHEET TITLE: LIGHTING ENERGY BUDGET FORMS SHEET NO: E1.1 CEILIN +9,_0f • 2 • • CEILING +8,-4' I I 1 I -J E2. CEILING +8'-4" rIP - -11 II II � —-1 JAN ITOR CSET II I E3 MEN' E3 t 3 RESTRO( /)II II II )) • _J --L E3 7 \: . /I I \ / I 1 \ / I r_-•r�� J I \ 1 lire.` �I CEILING +9'-0 MEN'S VESTIBULE TYPE El FIXTURE TYPICAL OF 10 SERVICE HALL _ I I HAND DRYER I I I I E4 I— I SERVIC HALL I-- E4 I— — - CEILING +9'-9" E4 ELECTRICAL FLOOR PLAN - DEMOLITION SCALE: 1 /4"=1'-0" GENERAL NOTES: 1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS AND SPECIFICATIONS. THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE BID, INDICATED ON ARCHITECTURAL, AND MECHANICAL, DATA, AND AUDIO VISUAL DRAWINGS. ADDITIONAL ELECTRICAL WORK REQUIRED IN THE BID IS ALSO LOCATED IN THE SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, AND MECHANICAL. SPECIFICATIONS FOR ADDITIONAL ELECTRICAL INFORMATION AND INCLUDE COSTS FOR THIS IN THE BID. 2. ALL CONDUIT IS INTENDED TO BE CONCEALED. CONTRACTOR SHALL PROVIDE TO ARCHITECT/OWNER SHOP DRAWINGS INDICATING ROUTING OF ANY INTENDED EXPOSED CONDUIT PRIOR TO ROUGH -IN FOR ARCHITECT/OWNERS APPROVAL. CONTRACTOR SHALL NOT START ROUGH -IN FOR CONDUIT UNTIL WRITTEN APPROVAL IS RECEIVED. 3. CONTRACTOR SHALL SEE ARCHITECTURAL DRAWINGS FOR THE FIRE WALL SEPARATIONS. CONTRACTOR SHALL PROVIDE CAULKING, SEAL -OFFS, ETC. AS REQUIRED BY CODE TO RETAIN FIRE WALL SEPARATION RATINGS. 4. ALL WALL PENETRATIONS SHALL BE NEATLY CORE -DRILLED, CAULKED AND SEALED TO MAINTAIN FIRE, AND WATERPROOF RATING. PATCH, REPAIR, AND PAINT TO MATCH EXISTING. 5. CONTRACTOR SHALL PROVIDE 1"C, FIRE ALARM CONDUCTORS TO ALL FIRE ALARM DEVICES. 6. CONTRACTOR SHALL REMOVE ALL ELECTRICAL DEVICES INDICATED ON THE ELECTRICAL DRAWING, ASSOCIATED, CONDUIT, AND WIRE. CONTRACTOR SHALL DISPOSE OF IN A LEGAL MANNER. CONTRACTOR SHALL INCLUDE A MINIMUM OF 4 HOURS IN THEIR BID TO FIELD VERIFY CIRCUITING FOR DEVICES NOT SHOWN TO BE REMOVED. PROVIDE NEW CONDUIT, WIRE AND RE -CONNECT ANY CIRCUITRY DISTURBED BY DEMOLITION OF EXISTING EQUIPMENT. E4 • E4 • CEIL +9' ING -9 E4 • • • I • • I • SERVIiCE HALL • • • r. • • E4 • E4 TYPE E1 FIXTURE TYPICAL OF 10 HAND DRYER • E4 II k^1 it a 4ill II -11 1•11 I 1 L J.I HAND DRYER TA1T. J -J EW ADA PEAKER/c pTROBE WOMEN'S • III I !LOCATION RESTROOM • ill•- mi• lli III Ll t l!E3 WOMEN'S VESTIBULE ---T E3 I\ /I • 1. \ /• I / L J' 7 — I• I • • I CEILING T-- • 1 +9'-0" E4 E3 I .\\ �Ertirt J1UU I � I —F_IL_ to fi I' ,I Y E2 III CEILING. . I Ir• ti +8,.4n. . 1 1j1 I � Jul 18-086 - E20.dwg 08/27/18- 12:02pm BRAC 23} 22 ELECTRICAL FLOOR PLAN - DEMOLITION SCALE: 1/4"=1'-0" ELECTRICAL NOTES: REMOVE EXISTING El FIXTURE, ASSOCIATED CONDUIT, WIRE AND DISPOSE OF IN A LEGAL MANNER. PROVIDE NEW 3/4"C-#12 CU CONDUCTORS AND RE -CONNECT CIRCUITING AND CONTROLS FOR NEW B2 AND B3 LIGHT FIXTURES SHOWN. REMOVE EXISTING E3 LIGHT FIXTURE, ASSOCIATED CONDUIT, WIRE AND DISPOSE OF IN A LEGAL MANNER. PROVIDE NEW 3/4"C-#12 CU CONDUCTORS AND RE -CONNECT CIRCUITING AND CONTROLS FOR NEW C1X LIGHT FIXTURES SHOWN. PROVIDE NEW CONDUIT, WIRE AND RELOCATE EXISTING ADA SPEAKER/STROBE TO NEW LOCATION INDICATED. RECONNECT TO FIRE ALARM CIRCUITING AND TEST. REMOVE EXISTING SPEAKER AND TURN OVER TO OWNER. PROVIDE NEW CONDUIT, AUDIO WIRE AND CONNECT NEW WALL SPEAKER TO EXISTING AUDIO ZONE. DISCONNECT EXISTING HAND DRYERS AND RECONNECT NEW. DISCONNECT AND REMOVE EXISTING FAUCET/SOAP SENSORS, ASSOCIATED CONDUIT, WIRE AND DISPOSE OF IN A LEGAL MANNER. PROVIDE 3/4"C-#12 CU CONDUCTORS AND CONNECT NEW SENSORS. LOCATIONS SHOWN ON ARCHITECTURAL AND PLUMBING DRAWINGS. DISCONNECT AND REMOVE EXISTING TOILET VALVE FLUSH SENSOR, ASSOCIATED CONDUIT, WIRE AND DISPOSE OF IN A LEGAL MANNER. PROVIDE 3/4"C-#12 CU CONDUCTORS AND CONNECT NEW SENSORS. LOCATIONS SHOWN ON ARCHITECTURAL AND PLUMBING DRAWINGS. E> REMOVE EXISTING E4 FIXTURE, ASSOCIATED CONDUIT, WIRE AND DISPOSE OF IN A LEGAL MANNER. PROVIDE NEW 3/4"C-#12 CU CONDUCTORS AND RE -CONNECT CIRCUITING AND CONTROLS FOR NEW A AND AX LIGHT FIXTURES SHOWN. EREVIEWED FOR CODE COMPLIANCE APPROVED FEB 252019 City of Tukwila BUILDING DIVISION RECEIVED ITY OF TUKWILA JAN 2 8 2019 PERMIT CENTER CROSS ENGINEERS, INC 923 MLK Jr. Way Tacoma, WA 98405 info@crossengineers.com Phone: (253) 759-0118 Job Number: 18-086 ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com SOUTHCENTER MALL TUKWILA, WASHINGTON CONSULTANT STAMP REVISIONS: PHASE / DELIVERABLE 60% APPROVAL SET DATE: DRAWN: PROJECT NO: 8/30/2018 JAE 18-086 APPROVED: SLW/SLH SHEET TITLE: PARTIAL ELECTRICAL DEMOLITION FLOOR PLANS SHEET NO: WOMEN'S RESTROOM (103) B3 WOMEN'S VESTIBULE (102) C1X ran r - SEVICE HALL (104) • SERVICE HALL (101) ELECTRICAL FLOOR PLAN - NEW SCALE: 1 /4"=1'-0" Ii AX SERVCC HALL B3 L� II, .'• ..I =fir r—i \ i L-J • • II rC� - _ F-L C.133 II t�L J- MEN'S iC:-c� RESTROOM L C� -nr B3 L C1X MEN'S VESTIBULE (107) C1X (109) • • %% =ll 4II , I _ -fir I J • 18-086 - E30.dwg 08/27/18- 12:03pm SHAC ELECTRICAL FLOOR PLAN - NEW SCALE: 1 /4"=1-0" C24) REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF T UKWILA JAN 2 8 2019 PERMIT CENTER CROSS ENGINEERS, INC 923 MLK Jr. Way Tacoma, WA 98405 info@crossengineers.com Phone: (253) 759-0118 Job Number: 18-086 ENGERT ARCHITECTURE LLC 26990 SE 22ND WAY SAMMAMISH, WA 98075 206 225-1443 www.engertarchitecture.com SOUTHCENTER MALL TUKWILA, WASHINGTON CONSULTANT STAMP REVISIONS: PHASE / DELIVERABLE 60% APPROVAL SET DATE: DRAWN: PROJECT NO: 8/30/2018 JAE 18-086 APPROVED: SHEET TITLE: PARTIAL ELECTRICAL FLOOR PLANS SHEET NO: SLW/SLH