HomeMy WebLinkAboutPermit EL19-0148 - AZ TRADING - 280 AMP SERVICE, FEEDER, PANEL, LIGHTING AND BRANCH CIRCUITSAZ TRADING INC (FRESH
AND GREEN)
3425 S 146TH ST
ELI9-0148
Parcel No:
Address:
Project Name:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-433. 3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
ELECTRICAL PERMIT
0040000827 Permit Number:
3425 S 146TH ST
AZ TRADING INC (FRESH AND GREEN)
Issue Date:
Permit Expires On:
EL19-0148
3/8/2019
9/4/2019
Owner:
Name:
Address:
JOYA JORGE & MARIA
2130 S DUPONT DR ROOF CORP OF
WA, ANAHEIM, WA, 92806
Contact Person:
Name: DAVID MARX
Address: 1308 CENTRAL AVE S - SUITE 1, KENT,
WA, 98032
Contractor:
Name: POWER FIX LLC
Address: 27505 135 AVE SE , KENT, WA, 98042
License No: POWERFL842RG
Lender:
Name:
Address:
I
Phone: (206) 349-6842
Phone: (206) 349-6842
Expiration Date: 12/7/2020
DESCRIPTION OF WORK:
INSTALL 280 AMP SERVICE, FEEDER, PANEL, INSTALL LIGHTING AND BRANCH CIRCUITS.
Valuation of single family: $0.00
Valuation of mf/comm: $36,000.00
Type of Work: TENANT IMP
Fees Collected: $970,48
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Date:3—F—(1
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state orlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this
development permitand agree tothe conditions attached tuthis permit.
�
SignaturePrint Name: /co
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***ELECTRICAL PERMIT CONDITIONS'
l: Acopy ofthe electrical work permit shall beposted orotherwise made readily accessible tuthe Electrical
Inspector ateach work site*
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical
Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations,
Chapter Z964GBvVA[and the Washington Cities Electrical Code.
S: When any portion of the electrical installation is to be hidden from view by permanent placement of parts
ofthe building, such equipment shall not beconcealed until ithas been inspected and approved bythe
Electrical Inspector.
G: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any
violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related
documentation that presumes togrant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shal I require additional work
permits. Where approved plans have been issued, revisions to the plans and additional review may be
required.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206)4]O-9350
2100 ELECTRICAL FINAL
7003 ROUG,H'|N[L[[TR|[AL
7002 SERVICE
7001 UNDERGROUND/SLAB
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
littp://www.TukwilaWA.upv
Electrical Vermit No. 0 iff
Project No.
Date Application Accepted:
Date Application Expires:
(tor office we ofilY)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.:
Site Address:4511-5 CS N4711 ST— Suite Number:
Tenant Name: Oil 4N/0 cit./ otrttaGen.Y New Tenant:
PROP RTY OWNER
Natne:
ottCre oyii
Address: 34/2S ....s. rif
City: State: State: /01/4
iCiso / L-09
Zip: 918/8
CONTACT PERSON - person receiving ail project
communication
11Mb iv
Address: -50.? ca_jvfnite.... Ave _cilia".
City:
ie-t0A,/ State: ivio, Zip: 90
Phone:0 8 ti2 Fax:
Email: e. X ('Crt.e.,AS
Valuation of Project (contracto(s bid price): $
Scope of Work (please provide detailed information
Floor: /37
WK-Y es El ..No
ELEC FRICAL CONTRACTOR INFORMATION
Company Name: X -Z-C_
Address: 27S45 /3577/ 46e- se
City: ice-A/7-- State: Am. Zip: '?8a5)1
Phone:.
.453-220-8f60Fax:
/ Contr Reg NoRweit. 4 s in leer.Exp Date:/z 07
Tukwila Business License No.;
ic .os
/4/s1a9e-1- berem•v&- 4A/0
Vc-
Will service be alt ed? [Ees E] No
Type of Use: LTV 6,11..cext.y
Type of work:
11 New 111 Addition Li Service Change
11 Low Voltage LI Generator [11 Fire Alarm
Property Served by:
Puget Sound Energy Seattle City Light
Adding more than 50 amps'? gtr<es Ej No
[1] Remodel
LJ Telecommunication
Tenant Improvement
Temporary Service
'to
W: \ Permit Center \ Applications -Handouts \ Permit Apphcattons\ PDF's\ Electrical Permit Application Revised I -17- 19.doex
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $180.00
(including an attached garage)
❑ Garages, pools, spas and outbuildings $ I20.00 ea
❑ Low voltage system:;
(alarm) $60.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANCES
❑ Service change or alteration $120.00
(no added/altered circuits)
❑ Service change with added/altered circuits S100.00
number of added circuits $10.00 ea
❑ Circuits added/altered without service change $60.00
(up to 5 circuits)
❑ Circuits added/altered without service change $60.00
(6 or more circuits)$i0.00 ea
❑ Meter/mast repair $80.00
❑ Low voltage systems $60.00
(alarm, furnace thermostat)
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $60.00
❑ Temporary service (generator) $90.00
0 Manufactured/mobile home service $100.00
(excluding garage or outbuilding)
0 Carnivals $100.00
Number of concessions $11.00 ea
Each ride and generator truck................$11.00 ea
EFFECf1VF:.IAWARY 1.. 20'I4 EACH
PERMIT WILL BE ASSESSED A 5%
TECHNOLOGY FEE**:
PERMIT APPLICATION NOTES -
Value of Construction -- In all cases, a value of construction amount should he entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current tee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY TII AT I I LAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME 'TO BE TRUE UNDER
PENALTY OF PERJURY BY TI11; LAWS OF THE STATE OF WASHINGTON, AND i AM AtJ'fIIORI/I?,D 1U APPLY FOR THiS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Print Name: .11-V I D M rt
Mailing Address: Z 7Sos /3S"rN fir
Date: l z f s 11
Day Telephone:2 3y 1512
Ghet 990412-
Stale Zip
WAPentnt Center\Applications-Hnndrrnts'Wermii Applicat,ons\PDF'stGlectncal Perm Application Rc, ised I ,1.7-19.doca
Page 2ot2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS.
PermitTRAK
ACCOUNT
QUANTITY
PAID
$1,040.10
EL19-0139 Address: 3425 5 146TH ST
Apn: 0040000827
$69.62
ELECTRICAL
$66.30
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$66.30
TECHNOLOGY FEE
$3.32
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$3.32
EL19-0148 Address: 3425 S 146TH ST
Apn: 0040000827 ;
$970.48
ELECTRICAL
$933.15
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$746.52
PLAN CHECK FEE
R000.345.832.00.00
0.00
$186.63
TECHNOLOGY FEE
$37.33
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R16882
R000.322.900.04.00
0.00
$37.33
$1,040.10
Date Paid: Friday, February 15, 2019
Paid By: POWER FIX LLC
Pay Method: CHECK 1366
Printed: Friday, February 15, 2019 4:09 PM 1 of 1
r
INSPECTION RECORD
Retain a copy with permit
INSPE TIQN NO. PE MIT NO,
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 438-9350
Project: ..
7ype of Inspection:
Address:
Date Called:
Special Instructions:
fDate
Wanted:
a
Requester:
Phone No:
7
2>
proved per applicable codes.
Corrections required prior to approval.
COMMENTS:
nspector:
Date: 011
REINSPECTIfl1 FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Suuthcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. EMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspection:
'Address:
Date Called:
SpecialSpecaal tnsuct,ons:
Date Wanted:
. •
Requester:
Phone No:
?
EjApproved per applicable codes.
Correctlons required prior to approval.
COMMENTS:
--- 1-74/1f1
k..)
P
REINSPECTIOt4 FEE REQUIRED. dor to next inspection. fee mtist be
paid at 6300 Southcenter Btvd.. Suite 100. Call to schedute reinspection.
INSPECTION RECORD
Retain a copy with permit
P CTION NO. PRMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 4 -9350
Project:
"ik-1
1
e o n ction:
1 t
Address:
(..
i
a Called:
.
Special Instruc io
:
1
Date Wanted:
a.
.
.
•
Requester:
Phone No:
Approved per applicable codes.
orrections required prior to approval.
ENT
of
In :
Date:
REINSPECT1ON FEE REQUIRED. Prior to next inspection. feemust be
paid at 6300 Southcenter Blvd.. Suite 100. Calf to schedule reinspec ion.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PEMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 67
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspec on:
Address
Date Called:
Special5pecial Instructions:
-. -
Date Wanted:
a.
•
•
Requester:
Phone No:
pOApproved per applicable codes.
MM ENTS:
Corrections required prior to approval.
Inspector:
Date:
REINSPECT ON FEE REQUIRED. Prior to next inspectiorr, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspecti-on.
oPERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL19-0148
PROJECT NAME: AZ TRADING INC
SITE ADDRESS: 3425 S 116 ST
X Original Plan Submittal
Response to Correction. Letter #
DATE: 02/15/19
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
rty
Building Division
Public Works
Fire Prevention Planning Division
Structural
Permit Coordinator II
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 02/19/19
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Corrections Required Denied
(corrections entered in Reviews) (ie: Zoning Issues
DUE DATE: 03/19/19
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg Fire ID Ping Li PW E Staff Initials:
12/18/2013
Home Espanol (..:Oritact.
Search L&I
Safety & Health Claims & Insurance
AilliWashington State Department of
alk)Labor& Industries
A-Z Index Hell)
My lid
Workplace Rights Trades & Licensing
POWER FIX LLC
Owner or tradesperson
Principals
MARX, DAVID M, DIRECTOR
Doing business as
POWER FIX LLC
WA UBI No,
603 539 248
27505 135TH AVE SE
KENT, WA 98042
206-349-6842
KING County
Business type
Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations,
Electrical Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
POWERFL842RG
Effective — expiration
12/07/2016— 12/07/2020
Designated administrator
Marx, David M
License type
Master Electrician
Bond
Travelers Cas and Surety Co of America
Bond account no.
106636850
Received by L&I
12/07/2016
•Savings
No savings accounts during the previous 6 year period.
License Violations
No license violations during the previous 6 year period.
Workers' comp
Active.
Meets current requirements.
License no.
MARX*DM886N6
$4,000 00
Effective date
11/28/2016
Expiration date
Until Canceled
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID Account is current.
637,530-00
Doing business as
GLOBE ELECTRIC
Estimated workers reported
Quarter 4 of Year 2018 "4 to 6 Workers"
L&I account contact
Help us improve
75 / MARVIN GREEN (360)902-4967 - Email: G 235@lni.wa.gov
Pubtic Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been Issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against thls contractor.
Workplace safety and health
No inspections during the previous 6 year period.
tljt Wu:Isar-Igloo State Dept. or Labor & Industries. Use of this site is subject to ate laws of the slate of titiatthlatttolt.
Help us improve
S 143.54' PROPERTY LINE
HALLER
ARCHITECTS LLC
EXISTING GRAVEL DRIVE
E 210.00' PROPERTY LINE
WAREHOUSE PARKING
EXISTING
ASPHALT
PAVING
NEW GATE
C o 6'-0" HIGH
CHAIN LINK
\ TRASH
C = ENCLOSURE
16'-6" TYP
EXISTING
ASPHALT
PAVING
EXISTING BUILDING
OVERALL = 7,090 SF
EXISTING WAREHOUSE
= 4,800 SF
200A Feeder From Service
[3] 250 XHHW AL PH
[1] 3/0 XHHW AL NEUT
[1] #2 XHHW AL GND
DELIVERY
DOOR
FIRST FLOOR INTERIOR SPACE
TO BE REMODELED = 2,135 SF
EXISTING
ASPHALT
PAVING
\ /'1
_I Y _
NE I GATE
2ND FL*IR
OFFICE E T
DOOR
12 POWER /
UTILTY POLE
EXISTING GATE
POWER LINE ABOVE \
(1=20LABOVE GROUN \--
EXISTING 6'-0" H METAL \
FENCE \
EXISTING
WAREHOUSE
TRUCK ROUTE
EXISTING 61-0"
METAL FENCE
ON TOP OF 2'-O"
HIGH CMU
RETAINING WALL
REQUIRED PARKING SPACES PER TUKWILA MUNICIPAL CODE SECTION 18.56.050:
REQUIREMENTS
PARKING PROVIDED
BIKE PARKING PROVIDED
WAREHOUSE
1 SPACE / 2,000 SF USABLE
FLOOR AREA
(3) SPACES
MIN. (2) SPACES REQ'D, (2)
SPACES PROVIDED
SECOND FLOOR
OFFICE
3.0 SPACES FOR EACH 1,000 SF OF
USABLE FLOOR AREA.
(6) SPACES
MIN. (2) SPACES REQ'D, (2)
SPACES PROVIDED
FIRST FLOOR
MARKET (T.I.)
1/ 300 SF USABLE FLOOR AREA
(18) SPACES
MIN. (2) SPACES REQ'D, (2)
SPACES PROVIDED
Replace/Upgrade existing 200A 120/240V 1 PH OH Tenant Service.
200A OH 120/240V Delta 3PH w/ Manual Bypass Meter Socket and Service Panel
EXISTING DECORATIVE
GRAVEL STRIP
EXISTING CONCRETE
WALK LEVEL W/
ASPHALT (NO STEP)
EXISTING '—
ASPHALT
PAVING
N 163.50' PROPERTY LINE
POWER / UTILTY POLE
New Service for Fresh and Green T.I.
200A OH 120/240V Delta 3PH w/ Manual Bypass Meter Socket and Service Disc.
SEPARATE PERMIT
R UIRED FOR:
Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
FILE C P�tici
Permit No. trr u
Plan review approval is subject to errors and
omissions Approval of -construction documents does
not auth.'nze the violation of any adopted code or
ordinance. Receipt of approved Field Copy and
`irsItloKra le g
By:
Date:T
City of Tukwila
BUILDING DIVISION
'7 I k. N J .
No : ie to tn: scope
of Worn ol!o' ap:.+roval of the
Tuh.wlla Building Dlvlslo .
NOTE: Revisions wilt require = new plan
Submittal and may include additional plan review.
9AR07 2219
RECEIVED
CITY OF TUKWILA
FEB 15 2019
PERMIT CENTER
EL194 149
12216 Corliss Avenue North
Seattle, WA 98133
TEL 206.235.0935
email: boyerscottl@gmail.com
PROJECT:
Fresh & Green Produce
Market T. I.
LOCATION:
3425 S 146th St
Tukwila, WA 98168
PREPARED FOR:
Abdi Adan
15006 Military Rd South
Tukwila, WA 98188
KEY MAP
NO. DATE REVISION
11/3/18 DEMOLITION PERMIT
12/17/18 T/I PERMIT
PROJECT DIRECTOR
SB
PROJECT MANAGER
SB
PROJECT ARCHITECT
SB
PROJECT TEAM MEMBER
CHECK
ARCHITECT SE
8117
REGISTERED
ARCHIT T
SCOTT A, B R
STATE OF WASHINGTON
TITLE
SITE PLAN
PROJECT NO.
18008.00
DATE
DECEMBER 17, 2018
PROJECT NETWORK PATH
SITE PLAN
SOUTH 146TH STREET
SHEET NUMBER
A1.01 SET
HALLER
ARCHITECTS LLC
CCESSIBLE TOI
UP
EXISTING
OVERHEAD DOOR
ENTRY 2ND
FLOOR OFFICE
( 111
REFLECTED CEILING / LIGHTING PLAN
LIGHT
FIXTURE
SCHEDULE
F1
1 x 4 SURFACE MOUNTED FLUORESCENT
FIXTURE w/LENS
%fi /A
•
F2
SURFACE MOUNTED LED FIXTURE
®
F3
COOLER / FREEZER LIGHT FIXTURE
PER MANUFACTURER
EXIT SIGN - ONE SIDE ILLUMINATED
EXIT
ib
M
BOTTOM OF EXISTING WD
GLULAM BEAM 8'-11" A.F.F.
EXISTING UNPAINTED WD
3X CAR DECKING TYP
EXISTING UNPAINTED
GLULAM BEAM TYP
FURRED PTD GWB
CEILING TYP
Lighting Alterations, Renovations & Building Additions
0 Less than 60% 0 60% or more • 0 Stand alone 0 Addition
Notes:3425
a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be
combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3.
b. For retrofits and building additions, provide Space Types and gross interior areas in the
Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall
existing builidng, include all applicable existing Space Types and gross interior areas.
c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table.
d. if less than 60% of existing fixtures will be replaced, provide total existing lighting wattage
(prior to retrofit) in the space provided in the Maximum Allowed Lighting table.
For Building Department Use
Lighting Budget
S 146th St
Tukwila, WA 98188
Building Area Method selected. Use LTG-INT-BLD form.
Location (plan #,
room #)
Space Type*
Allowed
Watts per ft2
Gross Interior
Area in ft2
Watts Allowed
(watts/ft2 x area)
Storefront
Sales area
1. 68
1473
2475
Storeback
Food preparation
0. 99
662
655
Atrium** Enter fleigltt:.
Existing Li htin EnteiEzist;.Watts;;
Retail Display Allowance frorri`MAT; DISPLAY; r".;,
* Select Table C405.5.2(2) category from drop down menu.
** For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W/ft. ht.,
above 40 feet is 0.02 W/ft. ht.
Building Area Method selected. Use LTG-INT-BLD form.
Total
Area
Allowed Watts
2135
3130
Location (plan #,
room #)
Fixture Description***
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Storefront
FMLWL48840 LED
22
40
880
Storeback
2GTL44400LMLP84
8
35
276
Storeback
Philips Lighting 8.5A19/LED/827 ND 120V
3
9
26
Storeback
FMLWL48840 LED
3
40
120
Retail Display Lighting from LTG-INT-DiSPL`AY .
Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt
1302
U
V
OO • PLIANC
NFPA 0. C
HAR 0 7 2019
•
City of Tukwila
BUILDING DIVISION
RECitIVLi)
CITY OF TUKWILA
jOk FEB1520+9
PERMIT CENTER
12216 Corliss Avenue North
Seattle, WA 98133
TEL 206.235.0935
email: boyerscottl@gmail.com
PROJECT:
Fresh & Green Produce
Market T. I.
LOCATION:
3425 S 146th St
Tukwila, WA 98168
PREPARED FOR:
Abdi Adan
15006 Military Rd South
Tukwila, WA 98188
KEY MAP
NO. DATE REVISION
11/3/18 DEMOLITION PERMIT
12/17/18 T/I PERMIT
PROJECT DIRECTOR
SB
PROJECT MANAGER
SB
PROJECT ARCHITECT
SB
PROJECT TEAM MEMBER
CHECK
ARCHITECT SEXL
8117
REGISTERED
ARCHIT _ T
SCOTT A. B R
STATE OF WASHINGTON
RTLE
REFLECTED
CEILING / LIGHTING
PLAN
PROJECT NO.
18008.00
DATE
DECEMBER 17, 2018
PROJECT NETWORK PATH
SHEET NUMBER
A2.02 SET
PANEL NO. P1A
SECTION: 1 OF 1
Bus: 120/240
30 4 Wire 225 AMP
O Main C.B. AMP
Q Main Lugs Only
Location: Meat Dept
Serving: Fresh and Green Grocery
A.I.C. Rating
Fully Rated Series Rated
I 'Feed
Thru Lugs
Lugs
Iso. Gnd. Bus
I 'Flush
Mount ,
Mount
I V 'Top Feed
E]
nSubFeed
n
'Surface
I -]Bottom Feed
Load
Type
Circuit Description
CONN
KVA
Circuit Breaker
PH
Circuit Breaker
CONN
KVA
Circuit Description
Load
Type
AMP
Pole
CKT
CKT
Pole
AMP
5 Door Freezer Cond.
824
15
3
1
A
2
3
20
1135
Meat Slicer Vertical 1
5 Door Freezer Cond.
824
15
3
3
B
4
3
20
1135
Meat Slicer Vertical 1
5 Door Freezer Cond.
824
15
3
5
c
6
3
20
1135
Meat Slicer Vertical 1
Walk In Cooler Cond.
747
15
3
7
A
8
3
20
1135
Meat Slicer Vertical 2
Walk In Cooler Cond.
747
15
3
9
B
10
3
20
1135
Meat Slicer Vertical 2
Walk In Cooler Cond.
747
15
3
11
C
12
3
20
1135
Meat SlicerVertical 2
I13
A
14
15
B
16
17
C
18
19
A
20
21
B
22
23
C
24
25
A
26
27
B
28
29
C
30
31
A
32
33
B
34
SUB FEEDPANELP1B
2252
35
C
36
2
225
SUB FEEDPANELP1B
SUB FEED PANEL P1B
225
2
37
A
38
2
225
SUB FEED PANEL P1B
39
B
40
41
C
42
CONNECTED LOAD
DEMAND LOAD
Total General -Purpose Receptacle (R) Load
@ 180VA/ea. KVA
Total General -Purpose Receptacle ( R ) Load @ 180VA/ea.,
100% for first 10 KVA & 50% for remainder KVA
Total Specific -Purpose (SP) Receptacles KVA
Total Specific -Purpose (SP) Receptacles KVA
Total Motor (M) Load KVA
Total Motor (M) Load KVA
Total Lighting (L) Load @ 125% KVA
Total Lighting (L) Load @ 125% KVA
Total HVAC (H) Load KVA
Total HVAC (H) Load KVA
TOTAL CONNECTED LOAD KVA
Largest Motor @ 125% KVA
CONNECTED AMP
Total / Phase
A
B
C
MINIMUM FEEDER CAPACITY
KVA AMP
TOTAL DEMAND LOAD KVA
PANEL NO. P1 B
SECTION:1 OF 1
Bus: 120/240
10 3 Wire 225 AMP
O Main C.B. AMP
Q Main Lugs Only
Location: Meat Dept
Serving: F resh and Green Grocery
A.I.C.
Rating
Fully Rated
Rated
Feed
Thru Lugs
Lugs
Iso. Gnd. Bus
❑
Flush Mount
Surface Mount
I I Top Feed
❑
❑ Series
❑SubFeed
❑
❑
n Bottom Feed
Load
Type
Circuit Description
CONN
KVA
Circuit Breaker
PH
Circuit Breaker
CONN
KVA
Circuit Description
Load
Type
AMP
Pole
CKT
CKT
Pole
AMP
Lighting Storefront
880
20
1
1
A
2
1
20
1500
Sign Circuit
Lighting Kitchen/Bathrooms
276
20
1
3
B
4
1
20
1800
Receptacles - S how Window
Receptacles - Point of Sale
360
20
1
5
A
6
1
20
1440
3 Door Beverage Cooler
Receptacles - Point of Sale
360
20
1
7
B
8
1
20
1800
2 Door Cooler
Receptacles - Credit Station
720
20
1
9
A
10
1
20
1308
Turbo Air TGM-50RS #1
Receptacles - Credit Station
720
20
1
11
B
12
1
20
1308
Turbo AirTGM-5ORS #2
Receptacles - Storefront
1080
20
1
13
A
14
1
20
1128
Display Cooler
Receptacles - Bathrooms
720
20
1
15
B
16
1
20
360
5 Door Freezer Lights/Controls
Meat Dept. - Deli Slicer
708
20
1
17
A
18
2
30
2537
5 Door Freezer Defrost
Meat Dept - Shrink Wrap
480
20
1
19
B
20
2
30
2537
5 Door Freezer Defrost
Receptacle - Meat Dept
1500
20
1
21
A
22
1
20
360
Walk In Freezer Lights/Controls
Receptacle - Meat Dept
1500
20
1
23
B
24
2
20
1500
Walk In Freezer Evaporator
25
A
26
2
20
1500
Walk In Freezer Evaporator
27
B
28
2
20
1236
Walk In Freezer Condenser
29
A
30
2
20
1236
Walk In Freezer Condenser
31
B
32
1
20
492
Walk In Cooler Evaporator
33
A
34
2
30
2500
HW Tank
35
B
36
2
30
2500
HW Tank
37
A
38
2
60
4692
Air Conditioner
39
B
40
2
60
4692
Air Conditioner
41
A
42
CONNECTED LOAD
DEMAND LOAD
Total General -Purpose Receptacle (R) Load
@ 180VA/ea. KVA
Total General -Purpose Receptacle ( R ) Load @ 180VA/ea.,
100% for first 10 KVA & 50% for remainder KVA
Total Specific -Purpose (SP) Receptacles KVA
Total Specific -Purpose (SP) Receptacles KVA
Total Motor (M) Load KVA
Total Motor (M) Load KVA
Total Lighting (L) Load @ 125% KVA
Total Lighting (L) Load @ 125% KVA
Total HVAC (H) Load KVA
Total HVAC (H) Load KVA
TOTAL CONNECTED LOAD KVA
Largest Motor @ 125% KVA
CONNECTED AMP
Total / Phase
A
B
MINIMUM FEEDER CAPACITY
KVA AMP
TOTAL DEMAND LOAD KVA
Fresh and Green Tenant Improvement
3425 S 146th St Tukwila, 98188
Power Plan - Service and Feeder Detail
2/15/19
FRESH AND GREEN GROCERY - One Line Block Riser
3425 S 146th St Tukwila, WA
EXISTING TENANT UPGRADED
SERVICE: ROOF CORP 120/240V 1 PH
NEW
120/240V 200A
3PH Delta OH
Mast
3X250 AL Phase
1 X3/0 AL Neutral
2.5" GRC Conduit
NEW 225A 3PH Safety Socket
Manual Bypass
SCL METER#: 2161712
3X250 AL Phase
1 X3/0 AL Neutral
1X#4 AL EGC
2.5" PVC
EXISTING
200A
120/240V
1 PH Panel
NEW
120/240V 200A
3PH Delta OH Mast
3X250 AL Phase
1 X3/0 AL Neutral
2.5" GRC Conduit
NEW 225A 3PH
Safety Socket
Manual Bypass
NEW
200A MCB
120/240V
3PH Panel
Service
Disc.
NEW FEEDER
3X250 AL Phase
1 X4/0 AL Neutral
1X#2 AL EGC
#4 CU GEC
NEW TENANT SERVICE
FRESH & GREEN 120/240V 3PH
NEW
SEC 1
P1A
200A MLO
120/240V
3PH Panel
NEW
SEC 2
P1B
200A
MLO
120/240V
1PH
Panel
NEW
225A
3PH
Service
Disc.
3X250 AL Phase
1 X3/0 AL Neutral
1X#4 AL EGC
2.5" PVC
NEW FEEDER
3X250 AL Phase
1 X4/0 AL Neutral
1X#2 AL EGC
#4 CU GEC
Tenant: Fresh and Green Grocery New Service: 120/240V 3PH Delta 225A
Loads
Description
Quantity
Voltage
Phase
VA Each
Amps Each
Demand
Total VA
Demand VA
Receptacle
General Purpose
20
120
1
180
1.5
100%
3600
3600
Receptacle
Show Window.
6
120
1
180
1.5
100%
1800
1800
Receptacle
Microwave
1
120
1
1050
8.8
65%
1050
682.5
Equipment
Food Warmer
1
120
1
1200
10
65%
1200
780
Equipment
Tea Warmer
1
120
1
1800
15
65%
1800
1170
Equipment
Espresso Machine
1
240
1
3600
15
65%
3600
2340
Equipment
Meat Slicer Vertical
2
240
3
3404.64
8.2
65%
6809.28
4426.032.
Equipment
Meat Slicer Deli
1
120
1
708
5.9
65%
708
460.2
Equipment
Shrink Wrap
1
120
1
480
4.0
65%
480
312
Equipment
Beverage Cooler 3 Door
1
120
1
1440
12.0
65%
1440
936
Equipment
2 Door Cooler
1
120
1_
1800
15.0
65%
1800
1170
Equipment
Turbo Air TGM-50RS
2
120
1
1308
10.9
65%
2616
1700.4
Equipment
Display Cooler
1
120
1
1128
9.4
65%
1128
733.2
Equipment
5 Door Freezer
1
240
1
5075
21.1
65%
5075
3298.75
Equipment
5 Door Freezer Comp.
1
240
3
4235
10.2
65%
4235
2752.75
Equipment
Walk In Cooler Evap.
1
120
1
492
4.1
65%
492
319.8
Equipment
Walk In Cooler Comp.
1
240
3
2242
5.4
65%
2242
1457.3
Equipment
Walk In Freezer Evap.
1
240
1
3000
12.5
65%
3000
1950
Equipment
Walk In Freezer Comp.
1
240
1
2472
10.3
65%
2472
1606.8
Equipment
Hot Water Heater
1
240
1
5000
20.8
65%
5000
3250
Equipment
4' LED FMLWL48840
25
120
1
40
0.3
125%
1000
1250
Equipment
2GTL44400LMLP84
8
120
1
34.5
0.3
125%
276
345
Lighting
LED A19 Bulb
3
120
1
9
0.1
125%
27
33.75
Lighting
Sign
1
120
1
1500
12.5
125%
1500
1875
HVAC
AC 5 Ton (LM)
1
240
1
9384
39.1
100%
9384,
9384
Voltage
VA
Demand VA
Amps
Demand Amps
Fresh and Green Grocery
120V 1PH
20917
17168
87
72
225A 120/240V Delta
240V 1PH
28531
21830
69
69
New LOAD
240V 3PH
13286
8636
32
21
TOTAL
Total
62734
44033
188
160.9
RECEIVED
CITY OF TUKWILA
FEB 15 2019
PERMIT CENTER
BOMPLIANCEWITH
NFPA 0-
MAR07 2019
City of Tukwila
BUILDING DIVISION