Loading...
HomeMy WebLinkAboutPermit EL19-0148 - AZ TRADING - 280 AMP SERVICE, FEEDER, PANEL, LIGHTING AND BRANCH CIRCUITSAZ TRADING INC (FRESH AND GREEN) 3425 S 146TH ST ELI9-0148 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-433. 3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 0040000827 Permit Number: 3425 S 146TH ST AZ TRADING INC (FRESH AND GREEN) Issue Date: Permit Expires On: EL19-0148 3/8/2019 9/4/2019 Owner: Name: Address: JOYA JORGE & MARIA 2130 S DUPONT DR ROOF CORP OF WA, ANAHEIM, WA, 92806 Contact Person: Name: DAVID MARX Address: 1308 CENTRAL AVE S - SUITE 1, KENT, WA, 98032 Contractor: Name: POWER FIX LLC Address: 27505 135 AVE SE , KENT, WA, 98042 License No: POWERFL842RG Lender: Name: Address: I Phone: (206) 349-6842 Phone: (206) 349-6842 Expiration Date: 12/7/2020 DESCRIPTION OF WORK: INSTALL 280 AMP SERVICE, FEEDER, PANEL, INSTALL LIGHTING AND BRANCH CIRCUITS. Valuation of single family: $0.00 Valuation of mf/comm: $36,000.00 Type of Work: TENANT IMP Fees Collected: $970,48 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date:3—F—(1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development permitand agree tothe conditions attached tuthis permit. � SignaturePrint Name: /co This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS' l: Acopy ofthe electrical work permit shall beposted orotherwise made readily accessible tuthe Electrical Inspector ateach work site* 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter Z964GBvVA[and the Washington Cities Electrical Code. S: When any portion of the electrical installation is to be hidden from view by permanent placement of parts ofthe building, such equipment shall not beconcealed until ithas been inspected and approved bythe Electrical Inspector. G: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes togrant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shal I require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)4]O-9350 2100 ELECTRICAL FINAL 7003 ROUG,H'|N[L[[TR|[AL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.upv Electrical Vermit No. 0 iff Project No. Date Application Accepted: Date Application Expires: (tor office we ofilY) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address:4511-5 CS N4711 ST— Suite Number: Tenant Name: Oil 4N/0 cit./ otrttaGen.Y New Tenant: PROP RTY OWNER Natne: ottCre oyii Address: 34/2S ....s. rif City: State: State: /01/4 iCiso / L-09 Zip: 918/8 CONTACT PERSON - person receiving ail project communication 11Mb iv Address: -50.? ca_jvfnite.... Ave _cilia". City: ie-t0A,/ State: ivio, Zip: 90 Phone:0 8 ti2 Fax: Email: e. X ('Crt.e.,AS Valuation of Project (contracto(s bid price): $ Scope of Work (please provide detailed information Floor: /37 WK-Y es El ..No ELEC FRICAL CONTRACTOR INFORMATION Company Name: X -Z-C_ Address: 27S45 /3577/ 46e- se City: ice-A/7-- State: Am. Zip: '?8a5)1 Phone:. .453-220-8f60Fax: / Contr Reg NoRweit. 4 s in leer.Exp Date:/z 07 Tukwila Business License No.; ic .os /4/s1a9e-1- berem•v&- 4A/0 Vc- Will service be alt ed? [Ees E] No Type of Use: LTV 6,11..cext.y Type of work: 11 New 111 Addition Li Service Change 11 Low Voltage LI Generator [11 Fire Alarm Property Served by: Puget Sound Energy Seattle City Light Adding more than 50 amps'? gtr<es Ej No [1] Remodel LJ Telecommunication Tenant Improvement Temporary Service 'to W: \ Permit Center \ Applications -Handouts \ Permit Apphcattons\ PDF's\ Electrical Permit Application Revised I -17- 19.doex Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $180.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $ I20.00 ea ❑ Low voltage system:; (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANCES ❑ Service change or alteration $120.00 (no added/altered circuits) ❑ Service change with added/altered circuits S100.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $60.00 (up to 5 circuits) ❑ Circuits added/altered without service change $60.00 (6 or more circuits)$i0.00 ea ❑ Meter/mast repair $80.00 ❑ Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $90.00 0 Manufactured/mobile home service $100.00 (excluding garage or outbuilding) 0 Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck................$11.00 ea EFFECf1VF:.IAWARY 1.. 20'I4 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE**: PERMIT APPLICATION NOTES - Value of Construction -- In all cases, a value of construction amount should he entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current tee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY TII AT I I LAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME 'TO BE TRUE UNDER PENALTY OF PERJURY BY TI11; LAWS OF THE STATE OF WASHINGTON, AND i AM AtJ'fIIORI/I?,D 1U APPLY FOR THiS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: .11-V I D M rt Mailing Address: Z 7Sos /3S"rN fir Date: l z f s 11 Day Telephone:2 3y 1512 Ghet 990412- Stale Zip WAPentnt Center\Applications-Hnndrrnts'Wermii Applicat,ons\PDF'stGlectncal Perm Application Rc, ised I ,1.7-19.doca Page 2ot2 Cash Register Receipt City of Tukwila DESCRIPTIONS. PermitTRAK ACCOUNT QUANTITY PAID $1,040.10 EL19-0139 Address: 3425 5 146TH ST Apn: 0040000827 $69.62 ELECTRICAL $66.30 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $66.30 TECHNOLOGY FEE $3.32 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.32 EL19-0148 Address: 3425 S 146TH ST Apn: 0040000827 ; $970.48 ELECTRICAL $933.15 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $746.52 PLAN CHECK FEE R000.345.832.00.00 0.00 $186.63 TECHNOLOGY FEE $37.33 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16882 R000.322.900.04.00 0.00 $37.33 $1,040.10 Date Paid: Friday, February 15, 2019 Paid By: POWER FIX LLC Pay Method: CHECK 1366 Printed: Friday, February 15, 2019 4:09 PM 1 of 1 r INSPECTION RECORD Retain a copy with permit INSPE TIQN NO. PE MIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: .. 7ype of Inspection: Address: Date Called: Special Instructions: fDate Wanted: a Requester: Phone No: 7 2> proved per applicable codes. Corrections required prior to approval. COMMENTS: nspector: Date: 011 REINSPECTIfl1 FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Suuthcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. EMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: 'Address: Date Called: SpecialSpecaal tnsuct,ons: Date Wanted: . • Requester: Phone No: ? EjApproved per applicable codes. Correctlons required prior to approval. COMMENTS: --- 1-74/1f1 k..) P REINSPECTIOt4 FEE REQUIRED. dor to next inspection. fee mtist be paid at 6300 Southcenter Btvd.. Suite 100. Call to schedute reinspection. INSPECTION RECORD Retain a copy with permit P CTION NO. PRMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 4 -9350 Project: "ik-1 1 e o n ction: 1 t Address: (.. i a Called: . Special Instruc io : 1 Date Wanted: a. . . • Requester: Phone No: Approved per applicable codes. orrections required prior to approval. ENT of In : Date: REINSPECT1ON FEE REQUIRED. Prior to next inspection. feemust be paid at 6300 Southcenter Blvd.. Suite 100. Calf to schedule reinspec ion. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PEMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 67 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspec on: Address Date Called: Special5pecial Instructions: -. - Date Wanted: a. • • Requester: Phone No: pOApproved per applicable codes. MM ENTS: Corrections required prior to approval. Inspector: Date: REINSPECT ON FEE REQUIRED. Prior to next inspectiorr, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspecti-on. oPERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0148 PROJECT NAME: AZ TRADING INC SITE ADDRESS: 3425 S 116 ST X Original Plan Submittal Response to Correction. Letter # DATE: 02/15/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: rty Building Division Public Works Fire Prevention Planning Division Structural Permit Coordinator II PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/19/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues DUE DATE: 03/19/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ID Ping Li PW E Staff Initials: 12/18/2013 Home Espanol (..:Oritact. Search L&I Safety & Health Claims & Insurance AilliWashington State Department of alk)Labor& Industries A-Z Index Hell) My lid Workplace Rights Trades & Licensing POWER FIX LLC Owner or tradesperson Principals MARX, DAVID M, DIRECTOR Doing business as POWER FIX LLC WA UBI No, 603 539 248 27505 135TH AVE SE KENT, WA 98042 206-349-6842 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations, Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. POWERFL842RG Effective — expiration 12/07/2016— 12/07/2020 Designated administrator Marx, David M License type Master Electrician Bond Travelers Cas and Surety Co of America Bond account no. 106636850 Received by L&I 12/07/2016 •Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Workers' comp Active. Meets current requirements. License no. MARX*DM886N6 $4,000 00 Effective date 11/28/2016 Expiration date Until Canceled Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 637,530-00 Doing business as GLOBE ELECTRIC Estimated workers reported Quarter 4 of Year 2018 "4 to 6 Workers" L&I account contact Help us improve 75 / MARVIN GREEN (360)902-4967 - Email: G 235@lni.wa.gov Pubtic Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been Issued against this contractor. Contractors not allowed to bid No debarments have been issued against thls contractor. Workplace safety and health No inspections during the previous 6 year period. tljt Wu:Isar-Igloo State Dept. or Labor & Industries. Use of this site is subject to ate laws of the slate of titiatthlatttolt. Help us improve S 143.54' PROPERTY LINE HALLER ARCHITECTS LLC EXISTING GRAVEL DRIVE E 210.00' PROPERTY LINE WAREHOUSE PARKING EXISTING ASPHALT PAVING NEW GATE C o 6'-0" HIGH CHAIN LINK \ TRASH C = ENCLOSURE 16'-6" TYP EXISTING ASPHALT PAVING EXISTING BUILDING OVERALL = 7,090 SF EXISTING WAREHOUSE = 4,800 SF 200A Feeder From Service [3] 250 XHHW AL PH [1] 3/0 XHHW AL NEUT [1] #2 XHHW AL GND DELIVERY DOOR FIRST FLOOR INTERIOR SPACE TO BE REMODELED = 2,135 SF EXISTING ASPHALT PAVING \ /'1 _I Y _ NE I GATE 2ND FL*IR OFFICE E T DOOR 12 POWER / UTILTY POLE EXISTING GATE POWER LINE ABOVE \ (1=20LABOVE GROUN \-- EXISTING 6'-0" H METAL \ FENCE \ EXISTING WAREHOUSE TRUCK ROUTE EXISTING 61-0" METAL FENCE ON TOP OF 2'-O" HIGH CMU RETAINING WALL REQUIRED PARKING SPACES PER TUKWILA MUNICIPAL CODE SECTION 18.56.050: REQUIREMENTS PARKING PROVIDED BIKE PARKING PROVIDED WAREHOUSE 1 SPACE / 2,000 SF USABLE FLOOR AREA (3) SPACES MIN. (2) SPACES REQ'D, (2) SPACES PROVIDED SECOND FLOOR OFFICE 3.0 SPACES FOR EACH 1,000 SF OF USABLE FLOOR AREA. (6) SPACES MIN. (2) SPACES REQ'D, (2) SPACES PROVIDED FIRST FLOOR MARKET (T.I.) 1/ 300 SF USABLE FLOOR AREA (18) SPACES MIN. (2) SPACES REQ'D, (2) SPACES PROVIDED Replace/Upgrade existing 200A 120/240V 1 PH OH Tenant Service. 200A OH 120/240V Delta 3PH w/ Manual Bypass Meter Socket and Service Panel EXISTING DECORATIVE GRAVEL STRIP EXISTING CONCRETE WALK LEVEL W/ ASPHALT (NO STEP) EXISTING '— ASPHALT PAVING N 163.50' PROPERTY LINE POWER / UTILTY POLE New Service for Fresh and Green T.I. 200A OH 120/240V Delta 3PH w/ Manual Bypass Meter Socket and Service Disc. SEPARATE PERMIT R UIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION FILE C P�tici Permit No. trr u Plan review approval is subject to errors and omissions Approval of -construction documents does not auth.'nze the violation of any adopted code or ordinance. Receipt of approved Field Copy and `irsItloKra le g By: Date:T City of Tukwila BUILDING DIVISION '7 I k. N J . No : ie to tn: scope of Worn ol!o' ap:.+roval of the Tuh.wlla Building Dlvlslo . NOTE: Revisions wilt require = new plan Submittal and may include additional plan review. 9AR07 2219 RECEIVED CITY OF TUKWILA FEB 15 2019 PERMIT CENTER EL194 149 12216 Corliss Avenue North Seattle, WA 98133 TEL 206.235.0935 email: boyerscottl@gmail.com PROJECT: Fresh & Green Produce Market T. I. LOCATION: 3425 S 146th St Tukwila, WA 98168 PREPARED FOR: Abdi Adan 15006 Military Rd South Tukwila, WA 98188 KEY MAP NO. DATE REVISION 11/3/18 DEMOLITION PERMIT 12/17/18 T/I PERMIT PROJECT DIRECTOR SB PROJECT MANAGER SB PROJECT ARCHITECT SB PROJECT TEAM MEMBER CHECK ARCHITECT SE 8117 REGISTERED ARCHIT T SCOTT A, B R STATE OF WASHINGTON TITLE SITE PLAN PROJECT NO. 18008.00 DATE DECEMBER 17, 2018 PROJECT NETWORK PATH SITE PLAN SOUTH 146TH STREET SHEET NUMBER A1.01 SET HALLER ARCHITECTS LLC CCESSIBLE TOI UP EXISTING OVERHEAD DOOR ENTRY 2ND FLOOR OFFICE ( 111 REFLECTED CEILING / LIGHTING PLAN LIGHT FIXTURE SCHEDULE F1 1 x 4 SURFACE MOUNTED FLUORESCENT FIXTURE w/LENS %fi /A • F2 SURFACE MOUNTED LED FIXTURE ® F3 COOLER / FREEZER LIGHT FIXTURE PER MANUFACTURER EXIT SIGN - ONE SIDE ILLUMINATED EXIT ib M BOTTOM OF EXISTING WD GLULAM BEAM 8'-11" A.F.F. EXISTING UNPAINTED WD 3X CAR DECKING TYP EXISTING UNPAINTED GLULAM BEAM TYP FURRED PTD GWB CEILING TYP Lighting Alterations, Renovations & Building Additions 0 Less than 60% 0 60% or more • 0 Stand alone 0 Addition Notes:3425 a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. if less than 60% of existing fixtures will be replaced, provide total existing lighting wattage (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. For Building Department Use Lighting Budget S 146th St Tukwila, WA 98188 Building Area Method selected. Use LTG-INT-BLD form. Location (plan #, room #) Space Type* Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) Storefront Sales area 1. 68 1473 2475 Storeback Food preparation 0. 99 662 655 Atrium** Enter fleigltt:. Existing Li htin EnteiEzist;.Watts;; Retail Display Allowance frorri`MAT; DISPLAY; r".;, * Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. Building Area Method selected. Use LTG-INT-BLD form. Total Area Allowed Watts 2135 3130 Location (plan #, room #) Fixture Description*** Number of Fixtures Watts/ Fixture Watts Proposed Storefront FMLWL48840 LED 22 40 880 Storeback 2GTL44400LMLP84 8 35 276 Storeback Philips Lighting 8.5A19/LED/827 ND 120V 3 9 26 Storeback FMLWL48840 LED 3 40 120 Retail Display Lighting from LTG-INT-DiSPL`AY . Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 1302 U V OO • PLIANC NFPA 0. C HAR 0 7 2019 • City of Tukwila BUILDING DIVISION RECitIVLi) CITY OF TUKWILA jOk FEB1520+9 PERMIT CENTER 12216 Corliss Avenue North Seattle, WA 98133 TEL 206.235.0935 email: boyerscottl@gmail.com PROJECT: Fresh & Green Produce Market T. I. LOCATION: 3425 S 146th St Tukwila, WA 98168 PREPARED FOR: Abdi Adan 15006 Military Rd South Tukwila, WA 98188 KEY MAP NO. DATE REVISION 11/3/18 DEMOLITION PERMIT 12/17/18 T/I PERMIT PROJECT DIRECTOR SB PROJECT MANAGER SB PROJECT ARCHITECT SB PROJECT TEAM MEMBER CHECK ARCHITECT SEXL 8117 REGISTERED ARCHIT _ T SCOTT A. B R STATE OF WASHINGTON RTLE REFLECTED CEILING / LIGHTING PLAN PROJECT NO. 18008.00 DATE DECEMBER 17, 2018 PROJECT NETWORK PATH SHEET NUMBER A2.02 SET PANEL NO. P1A SECTION: 1 OF 1 Bus: 120/240 30 4 Wire 225 AMP O Main C.B. AMP Q Main Lugs Only Location: Meat Dept Serving: Fresh and Green Grocery A.I.C. Rating Fully Rated Series Rated I 'Feed Thru Lugs Lugs Iso. Gnd. Bus I 'Flush Mount , Mount I V 'Top Feed E] nSubFeed n 'Surface I -]Bottom Feed Load Type Circuit Description CONN KVA Circuit Breaker PH Circuit Breaker CONN KVA Circuit Description Load Type AMP Pole CKT CKT Pole AMP 5 Door Freezer Cond. 824 15 3 1 A 2 3 20 1135 Meat Slicer Vertical 1 5 Door Freezer Cond. 824 15 3 3 B 4 3 20 1135 Meat Slicer Vertical 1 5 Door Freezer Cond. 824 15 3 5 c 6 3 20 1135 Meat Slicer Vertical 1 Walk In Cooler Cond. 747 15 3 7 A 8 3 20 1135 Meat Slicer Vertical 2 Walk In Cooler Cond. 747 15 3 9 B 10 3 20 1135 Meat Slicer Vertical 2 Walk In Cooler Cond. 747 15 3 11 C 12 3 20 1135 Meat SlicerVertical 2 I13 A 14 15 B 16 17 C 18 19 A 20 21 B 22 23 C 24 25 A 26 27 B 28 29 C 30 31 A 32 33 B 34 SUB FEEDPANELP1B 2252 35 C 36 2 225 SUB FEEDPANELP1B SUB FEED PANEL P1B 225 2 37 A 38 2 225 SUB FEED PANEL P1B 39 B 40 41 C 42 CONNECTED LOAD DEMAND LOAD Total General -Purpose Receptacle (R) Load @ 180VA/ea. KVA Total General -Purpose Receptacle ( R ) Load @ 180VA/ea., 100% for first 10 KVA & 50% for remainder KVA Total Specific -Purpose (SP) Receptacles KVA Total Specific -Purpose (SP) Receptacles KVA Total Motor (M) Load KVA Total Motor (M) Load KVA Total Lighting (L) Load @ 125% KVA Total Lighting (L) Load @ 125% KVA Total HVAC (H) Load KVA Total HVAC (H) Load KVA TOTAL CONNECTED LOAD KVA Largest Motor @ 125% KVA CONNECTED AMP Total / Phase A B C MINIMUM FEEDER CAPACITY KVA AMP TOTAL DEMAND LOAD KVA PANEL NO. P1 B SECTION:1 OF 1 Bus: 120/240 10 3 Wire 225 AMP O Main C.B. AMP Q Main Lugs Only Location: Meat Dept Serving: F resh and Green Grocery A.I.C. Rating Fully Rated Rated Feed Thru Lugs Lugs Iso. Gnd. Bus ❑ Flush Mount Surface Mount I I Top Feed ❑ ❑ Series ❑SubFeed ❑ ❑ n Bottom Feed Load Type Circuit Description CONN KVA Circuit Breaker PH Circuit Breaker CONN KVA Circuit Description Load Type AMP Pole CKT CKT Pole AMP Lighting Storefront 880 20 1 1 A 2 1 20 1500 Sign Circuit Lighting Kitchen/Bathrooms 276 20 1 3 B 4 1 20 1800 Receptacles - S how Window Receptacles - Point of Sale 360 20 1 5 A 6 1 20 1440 3 Door Beverage Cooler Receptacles - Point of Sale 360 20 1 7 B 8 1 20 1800 2 Door Cooler Receptacles - Credit Station 720 20 1 9 A 10 1 20 1308 Turbo Air TGM-50RS #1 Receptacles - Credit Station 720 20 1 11 B 12 1 20 1308 Turbo AirTGM-5ORS #2 Receptacles - Storefront 1080 20 1 13 A 14 1 20 1128 Display Cooler Receptacles - Bathrooms 720 20 1 15 B 16 1 20 360 5 Door Freezer Lights/Controls Meat Dept. - Deli Slicer 708 20 1 17 A 18 2 30 2537 5 Door Freezer Defrost Meat Dept - Shrink Wrap 480 20 1 19 B 20 2 30 2537 5 Door Freezer Defrost Receptacle - Meat Dept 1500 20 1 21 A 22 1 20 360 Walk In Freezer Lights/Controls Receptacle - Meat Dept 1500 20 1 23 B 24 2 20 1500 Walk In Freezer Evaporator 25 A 26 2 20 1500 Walk In Freezer Evaporator 27 B 28 2 20 1236 Walk In Freezer Condenser 29 A 30 2 20 1236 Walk In Freezer Condenser 31 B 32 1 20 492 Walk In Cooler Evaporator 33 A 34 2 30 2500 HW Tank 35 B 36 2 30 2500 HW Tank 37 A 38 2 60 4692 Air Conditioner 39 B 40 2 60 4692 Air Conditioner 41 A 42 CONNECTED LOAD DEMAND LOAD Total General -Purpose Receptacle (R) Load @ 180VA/ea. KVA Total General -Purpose Receptacle ( R ) Load @ 180VA/ea., 100% for first 10 KVA & 50% for remainder KVA Total Specific -Purpose (SP) Receptacles KVA Total Specific -Purpose (SP) Receptacles KVA Total Motor (M) Load KVA Total Motor (M) Load KVA Total Lighting (L) Load @ 125% KVA Total Lighting (L) Load @ 125% KVA Total HVAC (H) Load KVA Total HVAC (H) Load KVA TOTAL CONNECTED LOAD KVA Largest Motor @ 125% KVA CONNECTED AMP Total / Phase A B MINIMUM FEEDER CAPACITY KVA AMP TOTAL DEMAND LOAD KVA Fresh and Green Tenant Improvement 3425 S 146th St Tukwila, 98188 Power Plan - Service and Feeder Detail 2/15/19 FRESH AND GREEN GROCERY - One Line Block Riser 3425 S 146th St Tukwila, WA EXISTING TENANT UPGRADED SERVICE: ROOF CORP 120/240V 1 PH NEW 120/240V 200A 3PH Delta OH Mast 3X250 AL Phase 1 X3/0 AL Neutral 2.5" GRC Conduit NEW 225A 3PH Safety Socket Manual Bypass SCL METER#: 2161712 3X250 AL Phase 1 X3/0 AL Neutral 1X#4 AL EGC 2.5" PVC EXISTING 200A 120/240V 1 PH Panel NEW 120/240V 200A 3PH Delta OH Mast 3X250 AL Phase 1 X3/0 AL Neutral 2.5" GRC Conduit NEW 225A 3PH Safety Socket Manual Bypass NEW 200A MCB 120/240V 3PH Panel Service Disc. NEW FEEDER 3X250 AL Phase 1 X4/0 AL Neutral 1X#2 AL EGC #4 CU GEC NEW TENANT SERVICE FRESH & GREEN 120/240V 3PH NEW SEC 1 P1A 200A MLO 120/240V 3PH Panel NEW SEC 2 P1B 200A MLO 120/240V 1PH Panel NEW 225A 3PH Service Disc. 3X250 AL Phase 1 X3/0 AL Neutral 1X#4 AL EGC 2.5" PVC NEW FEEDER 3X250 AL Phase 1 X4/0 AL Neutral 1X#2 AL EGC #4 CU GEC Tenant: Fresh and Green Grocery New Service: 120/240V 3PH Delta 225A Loads Description Quantity Voltage Phase VA Each Amps Each Demand Total VA Demand VA Receptacle General Purpose 20 120 1 180 1.5 100% 3600 3600 Receptacle Show Window. 6 120 1 180 1.5 100% 1800 1800 Receptacle Microwave 1 120 1 1050 8.8 65% 1050 682.5 Equipment Food Warmer 1 120 1 1200 10 65% 1200 780 Equipment Tea Warmer 1 120 1 1800 15 65% 1800 1170 Equipment Espresso Machine 1 240 1 3600 15 65% 3600 2340 Equipment Meat Slicer Vertical 2 240 3 3404.64 8.2 65% 6809.28 4426.032. Equipment Meat Slicer Deli 1 120 1 708 5.9 65% 708 460.2 Equipment Shrink Wrap 1 120 1 480 4.0 65% 480 312 Equipment Beverage Cooler 3 Door 1 120 1 1440 12.0 65% 1440 936 Equipment 2 Door Cooler 1 120 1_ 1800 15.0 65% 1800 1170 Equipment Turbo Air TGM-50RS 2 120 1 1308 10.9 65% 2616 1700.4 Equipment Display Cooler 1 120 1 1128 9.4 65% 1128 733.2 Equipment 5 Door Freezer 1 240 1 5075 21.1 65% 5075 3298.75 Equipment 5 Door Freezer Comp. 1 240 3 4235 10.2 65% 4235 2752.75 Equipment Walk In Cooler Evap. 1 120 1 492 4.1 65% 492 319.8 Equipment Walk In Cooler Comp. 1 240 3 2242 5.4 65% 2242 1457.3 Equipment Walk In Freezer Evap. 1 240 1 3000 12.5 65% 3000 1950 Equipment Walk In Freezer Comp. 1 240 1 2472 10.3 65% 2472 1606.8 Equipment Hot Water Heater 1 240 1 5000 20.8 65% 5000 3250 Equipment 4' LED FMLWL48840 25 120 1 40 0.3 125% 1000 1250 Equipment 2GTL44400LMLP84 8 120 1 34.5 0.3 125% 276 345 Lighting LED A19 Bulb 3 120 1 9 0.1 125% 27 33.75 Lighting Sign 1 120 1 1500 12.5 125% 1500 1875 HVAC AC 5 Ton (LM) 1 240 1 9384 39.1 100% 9384, 9384 Voltage VA Demand VA Amps Demand Amps Fresh and Green Grocery 120V 1PH 20917 17168 87 72 225A 120/240V Delta 240V 1PH 28531 21830 69 69 New LOAD 240V 3PH 13286 8636 32 21 TOTAL Total 62734 44033 188 160.9 RECEIVED CITY OF TUKWILA FEB 15 2019 PERMIT CENTER BOMPLIANCEWITH NFPA 0- MAR07 2019 City of Tukwila BUILDING DIVISION