HomeMy WebLinkAboutPermit EL19-0168 - FUENTES RESIDENCE - INSTALL 8.64 KVW GRID-TIED, ROOF MOUNTED PV SYSTEM. 24 - SILFAB SLA360 SOLAR MODULES, 24 SOLAREDGEFUENTES RESIDENCE
4633 S 150TH ST
ELI9-0168
~^ xx " Tukwila
"~U~ * n v m^w oa
Department of Community Development
6]OV5outhcenterBoulevard, Suite #1OO
Tukwila, Washington 98188
Phwne:ZO6'431'367O
Inspection Request Line: 206-438'9350
VVebsite:h1tp://mwmw.Tukwi|aVVA.gov
Parcel No: 0043000375
Project Name: FUENTES RESIDENCE
ELECTRICAL PERMIT
Permit Number: EL19'0169
Issue Date: 3/13/2019
Permit Expires On: 9/9/2019
Owner:
Name:
Address
Contact Person:
Name:
YZAGU|RREEUlAK8+FUENT[5C
4633S150THST'TUKVVLA,WA,
98168
WILL HABENICHT
Address: lZ82UAVONDALEWAY, EVERETT
WA, 98204
Phone: (425)487-6000
Contractor:
Name: FORECAST ROOFING & SOLAR Phone: (425) 487-6GOO
Address 12D2DAVONDAL[WAY, EVERET[
WA, 98204
License No: FORE[RS883DG Expiration Date: 3/7/2020
Lender:
Name:
Address
'''
DESCRIPTION OF WORK:
INSTALL 8.64 KVW GRID-TIED, ROOF MOUNTED PV SYSTEM. 24 - SOLAR MODULES, 24 SOLAR EDGE POWER OPTIMIZERS, SOLAR EDGE INVERTER, MOUNTED ON SUNMODO EX=COMP MOUNTS, ADD 1 DEDICATED 20A, 120V CIRCUIT. REVISION #1 - ADD 200A SERVICE CHANGE/UPGRADEValuation ofsingle family: $16,50000
Valuation ofmf/c mm: $0.00
Type of Work: LOW VOLTAGE
Fees Collected: $28428
Electrical Service Provided by: SEAlTLECITY LIGHT
Water District: I25
Sewer District: VALLEY VIEW
Current Codes adopted bythe City of Tukwila.
International Building Code Edition:
international Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
VVACities Electrical Code:
VVACZ96-468:
Energy Code:
Permit Center Authorized Signature:
Date: 40 3
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting ofthis permit does not presume tngive authority to violate orcancel the provisions ufany other
state orlocal laws regulating construction orthe performance ofwork. |amauthorized tnsign and obtain this
development permit and agree to the conditions attached to this permit,
Signature:
Print Name:
/
Date: -3—/V-/'�'(
This permit shall become null and void ifthe work bnot commenced within l8Ddays for the date ofissuance, orif
the work is suspended orabandoned for aperiod of18Udays from the last inspection.
PERMIT CONDITIONS:
1: 'ELECTRICAL PERMIT [OND[F|ON5~**
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical
Inspector oteach work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical
Inspector.
4: All electrical work shall beinaccordance xithNFPA7O-NE[andrequiementsfnre|ectrica|instaUations,
Chapter Z96-4GBVVA[and the Washington Cities Electrical Code.
5: When any portion nfthe electrical installation is tobehidden from view bypermanent placement ofparts
of the building, such equipment shall not be concealed until it has been inspected and approved by the
Electrical Inspector.
6: The issuance ofanelectrical work permit shall not beconstrued tobpapermithor,oranappnma|of,any
violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits urrelated
documentation that presumes togrant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work
permits. Where approved plans have been issued, revisions tothe plans and additional review may be
required.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (2V6)43O985V
2100 ELECTRICAL FINAL
7003 ROUGH'|NELE[TR|[AL
7002 SERVICE
7001 UNDERGROUND/SLAB
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
0042000375
4633 S 150TH ST
Project Name: FUENTES RESIDENCE
ELECTRICAL PERMIT
Permit Number: EL19-0168
Issue Date: 3/13/2019
Permit Expires On: 9/9/2019
Owner:
Name:
Address:
YZAGUIRRE ELISA M+FUENTES C
4633 S 150TH ST, TUKWILA, WA,
98168
Contact Person:
Name: WILL HABENICHT Phone: (425) 487-6000
Address: 12820 AVONDALE WAY , EVERETT,
WA, 98204
Contractor:
Name: FORECAST ROOFING & SOLAR Phone: (425) 487-6000
Address: 12820 AVONDALE WAY, EVERETT,
WA, 98204
License No: FORECRS883DG Expiration Date: 3/7/2020
Lender:
Name:
Address:
DESCRIPTION OF WORK:
INSTALL 8.64 KVW GRID -TIED, ROOF MOUNTED PV SYSTEM. 24 - SILFAB SLA360 SOLAR MODULES, 24 SOLAREDGE
SE-P370-72c POWER OPTIMIZERS, 1- SOLAREDGE SE-7600H-US INVERTER, MOUNTED ON SUNMODO EX COMP
MOUNTS, ADD ONE DEDICATED 20A, 120V CIRCUIT
Valuation of single family: $16,500.00
Valuation of mf/comm: $0.00
Type of Work: LOW VOLTAGE
Fees Collected: $160.68
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125
Sewer District: VALLEY VIEW
Current Codes adopted by
he City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Permit Center Authorized Signature:
Da
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions oflaw and ordinances governing this work will becomplied with, whether specified herein nrnot.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state orlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this
development permit and agree tothe conditions attached tnthis permit.
Signature:
Print Name: /'7c=.L C,?
Date: f3_/�_/0y
This permit shall become null and void if the work bnot commenced within l8Odays for the date ofissuance, orif
the work is suspended urabandoned for aperiod ofl8Odays from the last inspection.
PERMIT CONDITIONS:
l: 'ELECTRICAL PERMIT C0NDnn0N5'
Z: Acopy ufthe electrical work permit shall bpposted orotherwise made readily accessible tothe Electrical
Inspector ateach work site.
3: Approved plans shall be maintained at the construction site and shall be readily available tnthe Electrical
Inspector.
4' All electrical work shall beinaccordance withNFPA70 NEC, and requirements for electrical installations,
Chapter l9646BVVACand the Washington Cities Electrical Code.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts
of the building, such equipment shall not be concealed umd| it has been inspected and approved by the
Electrical Inspector,
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any
violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits o/related
documentation that presumes ,ogrant this authority are therefore not valid,
7: Any change in the scope of work described by the electrical work permit shall require additional work
permits. Where approved plans have been issued, revisions tothe plans and additional review maybe
required.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (ZOb)43W-935V
2I00 ELECTRICAL FINAL
7003 ROUGH'|NELE[TR|[Ai
7002 SERVICE
CITY OF TUKRI
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
littp://1.vww,TukwilaW Lgov
Electrical Permit Na. E. 26____
Project No.
Date Application Accepted:
Date Application Expires: -t9
(For office use only)
ELECTRICAI, PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 0042000375
4633 S 150th St
Site Address: Suite Number: Floor:
Tenant Name: Chris Fuentes
PROPERTY OWNER
Name: Chris Fuentes
Address:4633 S 150th St
City: Tukwila
State: WA
Zip: 98188
CONTACT PERSON — person receiving all project
communication
Name: Will Habenicht
Address: 12820 Avondale Way
City: Everett stale: WA zip: 98204
Phone: 425-487-6000 Fax:
Email: office@forecastsolarcom
New Tenant: EI Yes V.No
ELECTRICAL CONTRACTOR INFORMATION
Company Name:Forecast Solar LLC
Address: 12820 Avondale Way
City: Everett State: WA ziP:98204
P e : 425-487-6000 Fax:
Contr Reg No.: FORECRS883DG Exp Date: 03/07/2020
Tukwila Business License No.;
Valuation of Project (contractor's bid price): $ 16,500
Scope of Work (please provide detailed information): Install 8.64 kW grid -tied, roof -mounted PV system.
24 - Silfab SLA360 solar modules, 24 SolarEdge SE-P370-72c power optimizers, 1 - SolarEdge
SE-7600H-US inverter, mounted on Sunmodo EZ Comp mounts. Add one dedicated 20A, 120V circuit.
Will service be altered? Elj Yes ID No Adding more than 50 amps? L:1 Yes ur No
Type of Use.
Type of work:
New 0 Addition ce Service Change Vei Remodel 0 Tenant Improvement
0 Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service
Property Served by:
Si Puget Sound Energy 0 Seattle City Light
TVAPermit CentoMpplicatiorishlarodozarAPornit ApplkatioarAPTIFAFI. ectri.nl Pcnith Appl ication %visa)? I-17- I 9.docs
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $180.00
(including an a*>Arhed garage)
❑ Garages, pools, spas and outbuildings $120.00 ea
❑ Low voltage systems
(alarm) $60.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $120.00
(no added/altered circuits)
ttii Servicechange with added/altered circuits $100.00
number of added circuits .....................$10.00 ea
❑ Circuits added/altered without service change.,.....—$60.00
(up to 5 circuits)
❑ Circuits added/altered without service change.......... $60.00
(6 or more circuits) $I0.00 ea
0 Meter/mast repair $80.00
❑ Low voltage systems $60.00
(alarm, furnace thermostat)
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical. contract,
j4IISCELLA]HEOUS FEES
❑ Temporary service (residential) $60.00
❑ Temporary service (generator) $90.00
❑ Manufactured/mobile home service $100.00
(excluding garage or outbuilding)
O Carnivals $100.00
Number aeon .......................... $11.00 ea
Each ride and generator truck.......... ...... $11.00 ea
***EFFECTIVE JAN ARY 1., 2014 EACI-'I
PERMIT` WILL BE ASSESSED A 5%
TECHNOLOGY FEE***
PERMIT APPLICATION NOTE
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fec schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR
Signature: Gt/:�t.// Date: 02/21/2019
Print Name: Will Habenicht
Mailing Address: 12820 Avondale Way Everett
City
VIVannit ColtatAppl sAandotRaNPavetAlylienipaPUFelElectrcal.Peru Application Reviwd 1-17-19.dnex
Day Telephone: 425-487-6000
WA 98204
Stan Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
Receipt. Number
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$123.60
E119-0168 Address: 4633 5 1SOTH ST
Apn: 00420003'75
$123.60
Credit Card Fee
$3.60
Credit Card Fee
R000.369,908.00,00
0,00
$3 60
ELECTRICAL
$120.00
PERMIT FEE SINGLE FAMILY
TOTAL. FEES PAID BY RECEIPT: R17 64
R000.322.101.00 00
0 00
$120.00
$123.60
Date Paid: Thursday, March 14, 2019
Paid By: FORECAST ROOFING [IC
Pay Method: CREDIT CARD 06995G
Printed: Thursday, March 14, 2019 3:53 PM 1 of 1
T
CO TUKWILA ETKAKIT
6200 SOUTH[ENTEK BLVD
TUKWILA, WA 98188
206'433'1870
CITY OF TUKWILA
Date: 03/I4/20I9 03:52:3.3 PM
CREDIT [«no 3xLs
VISA
CARD NUMBER: **********9130 K
TRAN AMOUNT: $123.00
APPROVAL [D: 86995G
RECORD #: 000
CLERK ID: Laurie
Thank you!
Customer Copy
•
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$160,68
EL19-0168 Address: 4633 $ 150TH ST Apn: 0042000375
$160.68
Credit Card Fee
$4.68
Credit Card Fee
R000.369.908,00.00
0.00
$4.68
ELECTRICAL
$150.00
PLAN CHECK FEE
R000.345.832.00.00
0,00
$30.00
PERMIT FEE SINGLE FAMILY
R000.322.101.00.00
0,00
$120.00
TECHNOLOGY FEE
$6.00
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R16959
R000.322.900.04.00
0.00
$6.00
$160.68
Date Paid: Friday, February 22, 2019
Paid By: KEVIN IVES
Pay Method: CREDIT CARD 022982
Printed: Friday, February 22, 2019 10:49 AM 1 of 1
SYSTEMS
CO TUxWIL4 ETKxKIT
0I00 S0UTHCENTEK BLVD
TUKWILA, W4 98188
206'433'1870
CITY OF TUKWILA
Date: 02/22/2919 10:48:38 4M
CnsozT [Axo SALE
VISA
CARD NUMBER: **********5626 K
TRAN AMOUNT: $188.68
APPROVAL CD: 022982
RECORD #: 000
CLERK ID: Bill
Thank you!
Customer Copy
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
P ' MIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431
Permit Inspection Request Line (206) 438- -50
Project:
Address:
ti 3)
Special Instructions:
s.
proved per applicable codes.
f
at Called:
?date Wanted:
Requester:
Phone No:�
' o3`f
rections required prior to approval.
COMMENTS:
as pecto
Date:
REINSPECTIO FEE REQUIRED. Prior to next inspection.'l`ee must be
paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspectbon.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. EMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 67
Permit Inspection Request Line (206) 438-9350
Projec :Iti4i(2,
Type of nspe
on: ,
Address:
-
0
Date Called:
special Ins
uc
s:
...
Date Wanted:
a. .
. .
Reque e :
Phone No:
a
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
Inspector:
Date:
REINSPECT ON FEE REQUIRED. Prior to next inspection. fee biut be
paid at 6300 Southcenter Blvd_ Suite 100. Call to schedule reinspection.
FILE COPY
Permit No. 110
Plan review approval is subject to errors and
omissions. Approval of construction aocuments aoes
not authorize the vioiation of any adopted code or
ordinance. Receipt of approved Fieia Copy and
coiitpns is a gea:
City of Tukwila
BUILDING DIVISION
REVISIONS
No chances snail be made to the scope
of work witnout prior approval of the
Tukwila Building Division.
NOTE: Revisions wili require a new plan
submittal and mav include additional plan review.
SEPARATE PERMIT
REQUIRED FOR:
0114 Mechanical
Electrical
Plumbing
CV Gas Piping
City of Tukwila
BUILDING DIVISION
IIAR07 ll
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 22 2019
PERMIT CENTER
w
FORECAST
SOLAR
(425) 487-6000
Designer Forecast Solar LLC
Address: 12820 Avondale Way
Everett, WA 98204
Email: info@ForecastSolar.com
Customer. Chris Fuentes
Address: 4633 S 150th St
Tukwila, WA 98188
Parcel #: 0042000375
Array Size
Modules
Module Wattage
Module Color
Inverter
Inverter Model
Optimizer
Racking System
Racking Color
Mounts
HR250.5m rail
HR250 - 4m rail
HR250 -3m rail
HR250.2m rail
HR250.1m rail
Equipment
8.64 kW
24 Silfab SLA360M
360
Clear
SolarEdge
SE•1600H•US
SE-P370.72c
Sunmodo
Clear
EZ Comp
2
2
6
4
4
Splice Kits
Grounds
End Clamp
Mid Clamps
8
36
30
ShelJob Details
Roof Type
Roof Pitch
Roof Hight
Azimuth
Mount Spacing
Wind Speed
Snow Load
Designer
Comp
6:12, 4:12
1.2stories
90,180, 270
6'
110
30
Will Habenicht
Installation
Electrician
Net Meter
Production
Meter
Inverte
Main Service
Panel
See One -Line diagram
for electrical specifications
aintain 18" from Ridge
314" EUT Conduit
#10 PV Wire, #8 EGC
FORRCASI
SOLAR
(425) 487.6000
Designer. Forecast Solar LLC
Addmss: 12820 Avondale Way
Everett, WA 98204
Email: info@ForecastSolar.com
Customer. Chris Fuentes
Address: 4633 S 150th St
Tukwila, WA 98188
Parcel #: 0042000375
Array Size
Modules
Module Wattage
Module Color
Inverter
Inverter Model
Optimizer
Racking System
Racking Color
Mounts
HR250.5m rail
Equipment
8.64 kW
24 Sidab SLA360M
360
Clear
SolarEdge
SE-7600H-US
SE-P370.72c
Sunmodo
Clear
EZ Comp
2
HR250.4m rail
HR250.3m rail
HR250 - 2m rail
HR250.1m rail
2
6
4
4
Splice Kits
Grounds
8
End Clamp
36
Mid Clamps
30
Roof Type
Roof Pitch
Roof Height
Azimuth
Mount Spacing
Wind Speed
Snow Load
Designer
SitelJob Details
Comp
6:12, 4:12
1.2stories
90,180, 270
6'
110
30
Will Habenichl
Installation
Electrician
String 1
20 modules connected in serie
with SE 320.60c optimizers
EGC
Stung 2
20 modules connected in series
with SE 320.60c optimizers
STRING 1
STRING 1
Max Power-Pku (W)
Max Power V-V (V)
Max Power C - Ike (A)
Dper ''pit V-V«(V)
Sh—or��c'uit C - Isc (A)
4320
Max Power-PNax (W)
4320
480
Max Power V - Vw (V)
480
15
Max Power C - IMP (A)
15
480
Open Circuit V - V« (V)
480
15
Short Circuit C - Isc (A)
15
I Inve
EGC4_
L1
Pt
ucuon
Meter
Net
Meter
UTILITYIGRID
in Electrical Panel
1
200A
40A
OPTIMIZER SPECS
FORECAST
SOLAR
(425) 487-6000
Designer Forecast Solar LLC
Address: 12820 Avondale Way
Everett, WA 98204
Email: info@ForecastSoIar,com
Customer. Chris Fuentes
Address: 4633 S 150th St
Tukwila, WA 98188
Parcel #: 0042000375
Equipment
Array Size
Module
Wattage
Module
Module Color
Inverter
Comm. Equip,
Optimizer
ManufacturerlModel
Max Output Current
SE 370-72c
15
Roof Type
Roof Pitch
8,64 kW
24 Silfab SLA360M
360
Clear
SE 7600HD
Zigbee
SE-P37Q-72c
SitelJob Details
Comp
4,6:12
Max Output Voltage
60
Installation
Max Sting DC Power (STC)
Max Input DC Power (STC)
Max Input Voltage
5250W
370
60
Max Input Current
13.75
Designer
Sales Person
Morgan Zehrung
Kevin Ives
MODULE SPECS
Max Short Circuit Current
11
ManufacturerlModel
Silfab SLA360
Efficiency (%)
99,5
Max Power-Pkz (W)
360
DC SIDE
AC SIDE
VuPp(V) 39,3
C - ILIA) 9,2
V-V«(l� 47.9
C -Isc (A) 9,71
18,5
INVERTER SPECS
Max Power U-
Max Power
A) 24 - Silfab PV module with one SE P370-72Cc per module, Rapid shutdown compliant
B) WT 2 gang 5-hole metal J-box.
C) SE 7600HD line inverter. Weather proof and rapid shutdown compliant
1-
z
a
5
0
w
0) Production meter 125A,14.4AWG,
E) Main electrical panel. 200A Cutler -Hammer BR. Point of Interconnection 40A 2-pole breaker.
1) 4 X #10 PV Wire, 2 X #8 bare copper EGC. 314' EMT conduit.
TEMP SPECS
CALC NOTES
DC WIRE SIZING CALCS
AVE. AMBIENT TEMP: 77F
RECORD LOW: -6F
CONDUIT HIGHT: 2'
n ROOF ADDER TEMP: 40F
ROOFTOP TEMP: 117
CONDUCTOR TEMP RATING:
TEMP CORRECTION: 90C
WIRE OCP = AMP
RATING X CONDUIT FILL
X TEMP DE -RATE
MAX AC 8 DC ISC TO BE
LESS OR EQUAL TO
WIRE OCP FOR WIRE TO
BE APPROVED BY 2017
kl:C 11n 7C iovmr,\ n oo KICP
NOTE: DC -to -DC CONVERTER
STRINGS 1 & 2 MAX ISC: 15A
WIRE GAUGE: #10
AMP RATING: 35A
CONDUIT FILL: 0.8
TEMP DE -RATE: 0.82
WIRE OCP: 23A
3) 3 X AWG #8 THWN
z
Open Circuit
Short Circuit
Efficiency (%)
ManufacturerlModel
Rated Output Power (W)
Max Cont. Output Current
Nominal Output Voltage
SE7600HD
7600
32
240
Nominal Output Frequency
Max Input DC Power (STC)
Max Input Voltage
Max Input Current
Efficiency (%)
59.3-60.5
11800W
480
20
99
ectrical S • ecificatons
SILFAB Si-t1—onocrystal fine
Test Conditions
STC NOCT
Module Power(Pmax)
Maximurnyower voltage (Vpmax)
Maximum power current (Ipmax)
Open circuit voltage (Voc)
Short circuit current (Isc)
Module efficiency
Maximum system volt!_ge (VDC)
Series fuse rating
Power Tolerance
V
A
V
A
360 272
35.37
7.73
9.20
47.9
9.71
18.5
V 1000
„
A 20
Wp -0/+5
Measurement conditions: STC 1000 Wfm2 • AM 1.5 • Temperature 25 *C • NOCT 800 WM& • AM 1.5 • Measurement uncertainty s 3%
Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by -0/+5W.
44.3
7,96
17.4
Tem • erature Ratings
Sti-FAI$ MOnOtr sta Ina
Temperature Coefficient Isc %/K__
Temperature Coefficient Voc %/K
Temperature Coefficient Pmax
NOCT (± 2°C)
Operating tem •erature
%/K
°C
°C
0.03
-0.30
-0.38
45
-40/-1-85
Mechanicat Pro. -rties and Com • onents
SILFAB SLG Monocrstailine
Module weight (± 1 kg)
Dimensions (H x L x D; ± 1mm)
Maximum surface load (wind/snow)*
Hail impact resistance
Cells
Glass
Backsheet
Frame
Bypass diodes
Cables and connectors (See installation manual)
kg
23
mm 1970 x 990 x 38
N/mz
2400 Pa upward / 5400 Pa downward
25 mm at 83 km/h
72 - Si rnonociystalline: 4 or 5 busbar - 156.75 x 156.75 mm
3.2 mm high transmittance, tempered, antireflective coating
Multilayer polyester -based
Anodized Al
3 diodes-45V/12A, IP67/1P68
1200 mm co 5.7 mm (4 mm2), MC4 compatible
Warranties
SILFAB SLG Monocr*staltine
Module product workmanship warranty
Linear power performance guarantee
Certifications
Product
25 years
30 year
ULC ORD C1703, UL 1703, IEC 61215, IEC 61730-1 and IEC 61730-2 Certified.
FSEC and CEC listed. IEC 62716 Ammonia Corrosion, IEC 61701:2011
Salt Mist Corrosion Certified
UL Fire Rating: Type 2 (Type 1 upon request)
Factory
*Please refer to the Safety and Installation Manual for mounting specifications.
A Warning: Read the installation and User Manual before handling, installing and operating modules.
Third -party generated pan files from
Fraunhofer-Institute for Solar Energy
Systems ISE are available for download
at: www.silfabsolar.com/downloads
S Ifa b
SOLO
El 0 tri
Silfab Solar Inc.
240 Courtneypark Drive East
Mississauga ON L5T 2Y3 Canada
Tel +1 905-255-2501 I Fax +1 905-696 267
EH Modules Per Pallet: 25
EH Pallets Per Truck: 30
Modules Per Truck: 750
RECEIVED
CITY OF TUKWILA
FEB 22 2019
PERMIT CENTER
D rair
"NAFPPLA TO1 Ear
info@silfabsolar.com 1 www.silfabsola ,com MAR 0 7 2019
Silfab Solar Inc.
800 Cornwall Ave City of Tukwila
Bellingham WA 98225 USA UILDING DIVISION
Tel +1 360-569-4733
ISO9001:2015
04.2 (a)
Grounding
Halo
ata and information is subject to modifications without notice. OSilfab,
Silfab-SIG-M•360-SF-OG-20190201-K • No reproduction of any kind is
or Orientations
sofa
Power Optimizer
P320 / P370 / P400 / P405 / P505
OPTIMIZER MODEL
P320
(for high -power
P370
(for higher -power
P400
(for 72 & 96-tell
P405
(for thin film
P505
I
(for higher
(typical module compatibility)
6i? cell modules)
60 and 72-cell
modules)
modules)
modules)
current modules) I
INPUT
Rated Input DC Power(i)
320
370
400
405
W
Absolute Maximum Input Voltage
(Voc at lowest temperature)
48
60
80
125
83
Vdc
MPPT Operating Range
8-48
8-60
8-80
12.5 - 105
12.5 - 83
Maximum Short Circuit Current (Isc)
11
10.1
14
Vdc
Adc
Maximum DC Input Current
13.75
12.63
17.5
Adc
Maximum Efficiency 99.5
Weighted Efficiency 98.8
Overvoltage Category Ii
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current 15
98,6
Maximum Output Voltage 60
Adc
85 Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power
Optimizer 1 ± 0.1
STANDARD COMPLIANCE
EMC
Safety
FCC Part15 Class 8, IEC61000-6-2, IEC61000-6-3
IEC62109-1 (class II safety), UL1741
RoHS
Yes
Vdc
INSTALLATION SPECIFICATIONS
Maximum Allowed System Voltage
1000
Vdc
Compatible inverters
All SolarEdge Single Phase and Three Phase inverters
Dimensions (W x Lx H) 128 x 152 x 28 / 5 x 5.97 x 1.1
128x152x36/
5 x 5.97 x 1.42
128x152x50/
5 x 5.97 x 1.96
128x152x59/
5x5.97x2.32
mm / in
Weight (including cables)
630/1.4
750/1.7
845/1.9
1064 / 23
Input Connector
MC41n
gr / Ib
Output Wire Type / Connector Double Insulated; MC4
Output Wire length 0.95 / 3:0 [[ 1.2 / 3.9 m / ft
Operating Temperature Range -40 - +85 / -40 - +185 °C / "F
Protection Rating IP68 / NEMA6P
Relative Humidity
0-100
Rated STC power of the module. Module of up to +5% power tolerance allowed.
Iz� For other connector types please contact SolarEdge
PV SYSTEM DESIGN USING
A SOLAREDGE INVERTERt3x°I
Minimum String Length P320, P370, P400
(Power Optimizers)
P405 / P505
SINGLE PHASE
HD -WAVE
SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
6
8
18
14
Maximum String Length
(Power Optimizers)
25
25
50j5l
Maximum Power per String
5700 (6000 with
SE7600-US - 5E11400- 1 5250
US)
6000
12750
W
Parallel Strings of Different Lengths
Yes
I'I For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf.
°I It is not allowed to mix P405/P505 with P320/P370/P400/P600/P700/P800 in one string.
Isl A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement
RECEIVED
CITY OF TUKWILA
S
S
000H-US j SE3800H-US ! SE5000H-US
OM -US/ SE7600H-US! SE10000H-USf SE11400H-US
LOUTPUT
Rated AC R5wer0u.7ua
Al AC Paw OupA
It Gu iii 1i�lgq.MJ 4aoeri.-M .••.•
.1/41,:21:225]--
AC 0uIu vas;0* I 1iters4 ta:4
FC ftniucercYil►�mt-'��..
Marrnxm Carts moos Culp.A Cu 'rem
.lam
Maririuxt Corelrwuxa C J pZA Cu.Yrw
240Y
LAttJ
GiiYl Strra.t+oFd
:yM,x irirs:ttlandog
Cuomo Gros LJ4'ae+e ttrs
612xb'u.n17iOwer 140Y
le4zrinLrn DC R.naxr_,C?S ' _..
Ib9DK�k6tai[#FC_'"ttO. AER.ra......�..,.
Ma Inpwt Stwxt Ckxtf CuMrtsl...»..,,
Gevu^d#ut lx, a[1m Or4
rt:Mtarne Fora CCrr.''vial
4650 .A00 TT50 9300; t» ;
5IA0 ' _.-- 'x?
,
IO.S i.iS...,._., 7.65
.................. 45...~».....
FOUYaSanttiti
.
:::::��........ ..........w.
'- 2.S
7.I I0
,........„.-.-
itk
3ra5C0 37 50
�1CT
4•
2#" 3t1.'6
4Y
A.
._....
W"
, ADDITIONAL FEATURES
17 C-4-r, iettkr, t+elaaoes
. YF.'7trCtCNaioIAiF:Jhi5iS.3.....
W r:d Shutdown . sac 1064 and 301T
P1435 Piitierre i{ 9aa tloey CR s�tar� Ajgr'y...,.............,._�T.,..,,.,.......,,,,-,..
»...,...,,..,.,....,..»,.,»,..,..,....,..,«...,,..,.....`.i7lS+aN1:.._„«.,..........................................«...,...
Roam ask Rapd'alLtdown xpcn X GAdiksrmr.-ct
«...,,,..»..,.
rSTANPAROCCl i1APia
..... ...........
94.4.1.—.......... .........:
LT4i tl1T4I SALif 1FJ5ri E5A Q2-1x Gt a9 AiCI +�Y5ii9 y L.I,C.. IN-02.».....b„n..,.,,....
..._ Cf#f1541RJ¢21,Rre.]4Qt] .__.. _....�__....,.
rCCPaet IS Gass33
.....,
Grid Wsrxu►.i3ordud;
fmrsans
NSTAt1A170:V 2PECTf1CliTki d5
[1C :'P-ea C> xA.Rt 3da j aCEI SY'rFz{3¢ /
.^,Y"v..,...........................,n»s....,..,»,.....«,.,».«
xonsiornveinSa'C.ySr;YetiFlmrxty
.''ni!? :wjri t s"2d' »,........
curtrye
.5,1 [ : ts'iMt.rein-.......,
Ferx'almWthL _-------_-__--
314"ettY^ €t .,?S It-6 WAG ..�_.
3/4 rnnirnum / 3,2 sv4 / 14-6 Ariz
.,..,.,,.«.........,.....,..,..,»....o.....x.........- .............,..rn.».,»,»
ITT x14.6x6.E/4S0x3T0x 174
ii:.g................„.
1. *QC.Ffili
SwhC!'1__
y4'mry. 1/14.4 AYYG
3/4 m rw.'exurn / I.3 silirxy ,/
..kl_3 x 9A.if$f11k9 = ............--.....,6x'F.3 540,eii0
F
.,.—
kre/mrn
_
.i 1.:4..
.
M eQ ream roman! .aata phew. rtriad s.,e..agpr ax+P.
Baum_ iad.irna.br ejM LC* 01.4.3 L01MCl
••rr: wawaQHaim'Nrmwua. mere. ram. N,..+.alarm•i+mr+.w IsMaithari,Tia.frawisraparalmwalaratrmaornanapdf
Jxa..Icni4h riruMLSQ7UMK
RECEIVED
CITY OF TUKWILA
FEB 22 2019
PERMIT CENTER
gRMIT MORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL19-0168 DATE: 02/22/19
PROJECT NAME: FUENTES RESIDENCE
SITE ADDRESS: 4633 S 150 ST
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
tv? 1121
Building Divisio
Public Works
Fire Prevention
Structural
Planning Division 1-1
Permit Coordinator s
PRELIMINARY REVIEW:
Not Applicable
n
DATE: 02/26/19
Structural Review Required
(no approval/review required)
REVIEWER'S INMALS: DATE:
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Corrections Required
(corrections entered in Reviews)
Denied
(ie: Zoning Issues)
DUE DATE: 03/26/19
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg El Fire E] Ping El PW Ej Staff initials:
I2/18/2013
City of Tukwila
REVISION
SUBMITTAL
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: 14'-' Plan Check/Permit Number:
Ej Response to Incomplete Letter #
El Response to Correction Letter #
LJ Revision # t after Permit is Issued
E Revision requested by a City Building Inspector or Plans Examiner
El Deferred Submittal #
Project Name: 1-z.4.
Project Address: qc-33
Contact Person:/li (e- Phone Number: ?— 5-7 -7 5- ce (Mg
Summary of Revision:
Ctdc, X
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
El Entered in TRAKiT on
WAPermit CenteetTemplatesWorrns‘Revision Submittal Formdoc
Revised: August 2015
Horn Espanol Contact
Safety & Health Claims & Insurance
0 Washington State Department of
Labor & Industries
(:)
[Search L &I
A-Mndex Help My 1,&1.
Workplace Rights Trades & Licensing
Forecast Roofing & Solar
Owner or tradesperson
Principals
Gorsuch, Greg S, PARTNER/MEMBER
Zehrung, Morgan, MANAGER
Zehrung, Morgan, AGENT
Doing business as
Forecast Roofing & Solar
WA UBI No.
602 515 428
Parent company
Forecast Roofing LLC
12820 Avondale Way
EVERETT, WA 98204
425-487-6000
SNOHOMISH County
Business type
Limited Liability Company
Governing persons
GREGORY
SCOTT
GORSUCH
MORGAN ZEHRUNG;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Electrical Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
FORECRS883DG
Effective — expiration
03/07/2012— 03/07/2020
Designated administrator
HERTZOG, KYLE R
License type
Electrical Administrator
Bond
Western Surety Co
Bond account no.
61291236
Received by L&I
03/07/2012
Savings
No savings accounts during the previous 6 year period.
License Violations
No license violations during the previous 6 year period.
Active.
Meets current requirements.
License no,
HERTZKR951 DU
$4,000.00
Effective date
03/06/2012
Expiration date
Until Canceled
0q11. ic8
Workers' comp
Help us improve