Loading...
HomeMy WebLinkAboutPermit EL19-0175 - BOEING #9-08.2 - REMOVE ELECTRICAL IN OFFICE SPACE, NEW LED LIGHTING, BRANCH CIRCUITS AND MECHANICAL POWERBOEING #9-08.2 9725 E MARGINAL WAY S 9-008 ELI 9-0175 Parcel No: 0 City of Tukwila Department of Community Development 300 Southcente,Boulevard, Suite #1O0 Tukwila, Washington 98188 Phone:206-431-m670 Inspection Request Line: 206-438-9350 Web site: http://wmmv'Tukwi|aVVA.mov ELECTRICAL PERMIT 5624201032 Permit Number: EL19'0175 972EEMARGINAL WAY S8LOG9-008 Issue Date: 4/16/2019 Permit Expires On: 10/13/2019 Project Name: BOEING #9-08.2 Owner: Contact Person: Contractor: License No: Address: B0BNGCOMPANY THE POBOX 37O7w1/CZO'59PROPERTY TAX DEPT, SEAlTLE'WA, gOIZ4 SEQU0YAMELECTRIC LLC(ELECTR|[AU 15135NE 9ZND6T'REDMOND, WA, 9DD5Z'3Sl9 ''' Phone (425)766-2184 Phone: (425)814-6000 Expiration Date:1/30/2OZ1 DESCRIPTION OF WORK: REMOVE EXISTING ELECTRICAL |mOFFICE SPACE, INSTALL NEW LED LIGHTING, ASSOCIATED BRANCH CIRCUITS AND MECHANICAL POWER FOR OFFICE SPACE TI BUILD -OUT. Valuation ofsingle family: $0.00 Valuation ofmf/connm: $735'581.00 Type ofWork: TENANT IMP Fees Collected: $10,624.80 Electrical Service Provided by: SEx7TLECITY LIGHT Water District: TUKVV|LA Sewer District: TUKVVLA Current Codes adopted bythe City ofTukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVAC296-46B: Code: ermit Center Authorized Signature: / "�/'//a Date: oy//�'/7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this develo m : t e r it and agree'to thQ-yonditions attacM4'ed to this permit. Signature: Print Name: Date: H 1 b\ \ ct This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWIc Community Development epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Per No. Ei-19 ° (7 5 Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 9725 E Marginal Way S, Tukwila, WA 98108 Suite Number: 9-08.2 Floor: 2, Co1.D4 Tenant Name: The Boeing Company PROPERTY OWNER Name: The Boeing Company Address: PO Box 3707 J/C 20-59 Property Tax Dept City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Justin Horvath Address: 15135 NE 92nd Street City: Redmond State: WA Zip: 98052 Phone: (425) 766-2184 Fax: (425) 814-6003 Email: justin.horvath@sequoyah.com New Tenant: jJ Yes VI ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Sequoyah Electric, LLC Address: 15135 NE 92nd Street City: Redmond State: WA Zip: 98052 Fax: Phone: (425) 814-6000 (425) 814-6003 Contr Reg No.: SEQUOEL977t Exp Date: 01/30/2021 Tukwila Business License No.; BUS-099435 Valuation of Project (contractor's bid price): $ 735,581 Remove existing electrical in office space; Scope of Work (please provide detailed information): install new LED lighting, associated branch circuits, and mechanical power for office space/TI build -out. Will service be altered? J Yes GZI No Adding more than 50 amps? rip Yes El No Type of Use. commercial TI Type of work: 0 New 0 Addition 0 Service Change IZ1 Remodel 0 Tenant Improvement 0 Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served b 0 Puget Sound Energy 121 Seattle City Light W:Wermit Center\ Applications -Handouts Permit Applications PDE's Electrical Permit Application Revised I I - I 7.docx Revised: January 2017 bh RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: JUstin Horvath'" Day Telephone: (425) 766-2184 Mailing Address: 15135 Ne 92nd Street, Redmond, WA 98052 State Zip Date: 02/25/2019 City W:\Permit Center\Applications-Handouts\Permit Applications \PDF's\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT 1 PermitTRAK QUANTITY . I PAID $10,624.80 EL19-0175 Address: 9725 E MARGINAL WAY S BLDG 9-008 Apn: 5624201032 $10,624.80 ELECTRICAL $1O216.15 PERMIT FEE MULTI-FAM/COMM R000.322. 01.00.00 0.00 $8472.92 PLAN CHECK FEE R000.345. 2.00.00 0.00 $2,043.23 TECHNOLOGY FEE $408.65 TECHNOLOGY FEE R000.322.900.04.00 0.00 $408.65 TOTAL FEES PAID BY RECEIPT: R16975 .$10,624.80 Date Paid: Monday, February 25, 2019 Paid By: SEQUOYAH LLC Pay Method: CHECK 556675 Printed: Monday, February 25, 2019 1:25 PM 1 of 1 WYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-94..64 Project: l' a lop - - • L./ r:i Alitlof Address: 1Al..-&\ Date -lied: Special Instructions: Date Wanted: 7 7 a.m. p.m. Requester: Phone No: V(JIMMENTS: Approved per applicable codes. El Corrections required prior to approval. 11 L4 nspector. Date: in REINSPECT ON FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: S2 Type of Insp c on: , Address: Date Called: Special In uc ns: 0 I i bte Wanted: . . Re ester: Ph e No: 2 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 , ZREINSPECT! N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 047 17 9-08.2 Tenant Improvement 181-093.350 November 27, 2018 APPENDIX A PANEL SCHEDULES Boeing #: W5563002 Appendix A — Panel Schedules FIL EL 0-- o 17 APPENDIX A — PANEL SCHEDULES PAGE - 1 RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER 7) ELECTRICAL PANEL SCHEDULE Panel Designation 2A15-1 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 60A MCB 100A,208Y/120V, 3PH,4W 9-08-2E61 CASNE 1/26/2018 2A15-1 Location, bldg. 9.08 2ND FLR col. A.8/15.5 Date Installed TBD Feeder Size 1-1/2"C, 4#1, #8 GND Fed From 2C15/2,4,6 Revised Ckt Date Revised Job Number VIA 100A FILTER NEW PANEL 11.27.18 W5563002 Ckt Breaker Type 1 Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame Ph A la 20A #12 LED LIGHT FIXTURES 6.0 7-7 c - c,,,' 3b 20A #12 AMS ---. r 7'r: 5c 30A #10 (1) L5-30 RECEPT. *!P'c c ,,,,e. 7:,- r 24.0 7a 20A SPARE 9b 20A SPARE .7.7-: r ?„- a ,--.: r ilc 20A SPARE ,7 7. !.M. C ,- r D : f F 13a 20A SPARE 't- tt - c,i, 1-,,,! 15b 20A SPARE 17c ' 20A SPARE .7.'crq: c ',,,t- C'C r 2a 20A #12 (4) QUAD RECEPT. 12.0 ,.:- r -.# -..D.i-!. - T..- •i- 4b 20A #12 (3) QUAD RECEPT. r, r r, a 9.0 tFl.,, 6c 20A SPARE ,-" a C, :,.:- '.,r.rr,,c'F 8a 20A SPARE ..D:7,'. t!i^ 10b 20A SPARE r., -,.. 7 7-6 r.ii t., rr- 12c 20A SPARE ":. 7 6r. ,--c 14a 35A 3P HEAT PUMP HP2B16 25 '.,,,r - C, i,' c r 16b #8 ., ,,.,„ ,, ,:.- k.... .• c ''r a 25 -1,?-- p-- r 18c #8 '! r. a c 0 ... r (- a r. 25 TOTAL 43 34 49 ELECTRICAL PANEL SCHEDULE Panel Designation 2A15 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 100A MCB 150A,208Y/120V, 3PH,4W 9-08-2E61 CASNE 11/26/2018 ZA15 Location, bldg. 9.08 2ND FLR col. A.5/15.5 Date Installed TBD Feeder Size 1-1/2" 4#1/0, #6GND Fed From 2C15/1,3,5 Revised Ckt Date Revised Job Number VIA 150A FILTER NEW PANEL 11.26.18 W5563002 Ckt Breaker Type Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame Ph A la 20A #12 LED LIGHT FIXTURES 3.0 3b 20A #12 AMS 5c 30A 2P #10 (1) L6-30 RECEPT. •7: • f- 1- I i. r ,::` f: '/ 7a #10 ' - •-: "7 - ",- r'' ' 9b 30A #10 (1) L5-30 RECEPT. 11c 30A #10 (1) L5-30 RECEPT. 13a 45A 3P #6 HEAT PUMP HP2A15 35 8 r 15b #6 • , . 35 8 • 17c #6 : - -* 7,..-. - r •-• :,1 ' ri 35.8 2a 20A #12 (4) QUAD RECEPT. 4...„, .1.) , 1 •,.c, r., , ..r ? r: ,- ,, • :;, •o• ".• - 4b 30A 2P #10 (1) L6-30 RECEPT. r• .' .. •r. :‘ : , L. i 6c #10 8a 30A #10 (1) L5-30 RECEPT. r ' n. • '-'. 0 1` e '' 10b 30A #10 (1) L5-30 RECEPT. 12c 20A #12 (1) QUAD RECEPT. . f:. £0 r 1..1-4 :'`J .t.; , . . --8`r-17,11- 1 3 14a 40A 3P• #8 SPARE 16b #8 SPARE ., •,, r 0 - r,.7•-,tr .-.1 -% c r•rc 18c #8 SPARE •,•• xi •-• ''..c - r 1.; k". ,. t :tr .!...` ftr f TOTAL 51 36 39 / \ / ELECTRICAL PANEL SCHEDULE Panel Designation 2A17-1 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 60A MCB 1/26/2018 2A17-1 Location, bldg. 9.08 2ND FLR Date Installed Feeder Size 100A,208Y/120V, 3PH,4W Fed From 9-08-2E62 CASNE Revised Ckt Date Revised Job Number col. A.9/18 TBD 1-1/4"C, 4#4, #8 GND 2B14/18,20,22 VIA 60A FILTER NEW PANEL 11.27.18 W5563002 Ckt Breaker Type Wire Size Load Served Load Amps Location Frame Trip Ph A Ph B Ph C la 20A #12 LED LIGHT FIXTURES 2.3 3b 20A #12 (3) DUPLEX RECEPT. ' r r ‘ 4.5 fan r r r 5c 20A SPARE 7., 7a 20A 3P #10 HEAT PUMP HP2B18 16.0 9b #10 7 r - 7...: 16 11c #10 :f.7 nr.:, :-.7.r,f-1 16 13a 20A SPARE •r:r. f- n f r r n•-: r 15b 20A SPARE f..5!:' far 17c 20A SPARE - c f."; r. ','• " r 7 f 2a 20A #12 (3) DUPLEX RECEPT. 4.5 .rr - f„',,,::' 'or: f :: 4b 20A SPARE " 6c 20A SPARE -1.1 :•)r o : tr. r I 8a 20A SPARE u..: tr:5 5: 1 ' tic. .r. • 5, 1.' I? 1;.. 10b 20A SPARE '• ' ',. ' 7, r 0," 12c 20A SPARE -tr..,7,1'F 14a 20A SPARE c ,-- far 16b , 20A SPARE o, , ;h, a .•,,. c ,,,t 18c 20A SPARE .,," .• %,., n c, or c. V k: 14:cr.r: f TOTAL 23 21 16 ELECTRICAL PANEL SCHEDULE Panel Designation 2A17 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 60A MCB 100A,208Y/120V, 3PH,4W 9-08-2E62 CASNE 11/26/2018 2A17 Location, bldg. 9.08 2ND FLR col. A.5/18 Date Installed TBD Feeder Size 1-1/4"C, 4#4, #8 GND Fed From 2B14/13,15,17 Revised Ckt Date Revised Job Number VIA 60A FILTER NEW PANEL 11.27.18 W5563002 Ckt Breaker Type I Trip Wire Size Load Served Load Am s Location Frame Ph A Ph B 1 Ph C la 20A #12 LED LIGHT FIXTURES 2.3 4:' r c -.:.-t: ;-..,e..• ;',.f-- :. 3b 30A #10 (1) L5-30 RECEPT. 1 PC r C,r n,r c 5c 20A SPARE 7. t, CT. .. . i 4:. .. . 7a 35A 3P #8 HEAT PUMP HP2A18 25 1 r r - n i rr. r ' - 9b #8 - r - t7 25 r:c: •..• r 7 11c .,;tc a 25 13a 20A SPARE r r r,•.---r -- 15b 20A SPARE ,. - r ' - - — 17c 20A SPARE r, 1 0 :. 0 -, r 2a 20A #12 (3) QUAD RECEPT. 9.0 , t. ..... e,' ':-,..7:r: ''., r ; 1% r, c f.: r, •.- 4b 20A #12 (1) QUAD RECEPT. n.:- 11, r 3.0 6c 20A SPARE 8a 20A SPARE .:, t ;-. c.,t: , 7:r r c•-• v. ?- - t., t- • 1-t1 vl, • 10b 20A SPARE 7 r, Vr- AT C 'S". C.,,." 12c 20A SPARE ,r ..,,t.., 7:- r Et 1- iff, ,r r 0 r f 14a 20A SPARE 16b 20A SPARE . v, 4 ... - r.. r: r :.; ;:f:': 18c 20A SPARE -,c(Ic tr., TOTAL 37 28 25 ELECTRICAL PANEL SCHEDULE Panel Designation 2B14 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 60A MCB 100A,208Y/120V, 3PH,4W 9-08-2E61 CASNE Location, bldg. Date Installed Feeder Size Fed From Revised Ckt Date Revised Job Number col. 11/26/2018 2814 9.08 2ND FLR B14.5 TBD 1-1/2"C, 4#1, #8 GND 2C15/7,9,11 VIA 100A FILTER NEW PANEL 11.26.18 W 5563002 Ckt Breaker Type Wire Size Load Served Load Amps Location Frame Trip Ph A Ph B Ph C la 20A #12 LED LIGHT FIXTURES 4.0 3b 20A #12 AMS - r ,. r D r r 5c 20A SPARE - 7 r r 7, t, r .- r 7a 35A #8 HEAT PUMP HP2B15 24 - - a - 7 - .77 r • 9b #8 •, ft' a 24 11c #8 7:<:' Of , :,i- r'C:'; 24 13a 20A SPARE ,.r,-. tro tt 15b 20A SPARE ^.:. . . r. rr r 7 17c 20A SPARE 7 a r o 2a 20A #12 (4) QUAD RECEPT. 12.0- .. ..--' • 0 .• :0.r 4b 30A #10 (1) L5-30 RECEPT. •. -4, 1,,i '....; ;..,..., 6c 20A #12 (1) QUAD RECEPT. '' Cr.% C tU.- .7- 3.0 8a 20A SPARE .: rtt,..r r; r.,' .r'. V. 10b 20A SPARE ,- 77.r.c.'. r; r: ro c :-.' 7- 12c 20A SPARE 14a 20A SPARE 't' r r fl' z77 7' a' .7. 16b 20A SPARE ' rt r r -. 18c 20A SPARE TOTAL 40 24 27 Panel Designation Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer ELECTRICAL PANEL SCHEDULE 2B15 60A MCB 100A,208Y/120V, 3PH,4W 9-08-2E62 CASNE Location, bldg. Date Installed Feeder Size Fed From Revised Ckt Date Revised Job Number col. 11/26/2018 2815 9.08 2ND FLR B.8/16 TBD 1-1/2"C, 4#1, #8 GND 2C15/14,16,18 VIA 100A FILTER NEW PANEL 11.27.18 W5563002 Ckt Breaker Type Wire Size Load Served Load Amps Location Frame Trip Ph A Ph B Ph C la 20A #12 LED LIGHT FIXTURES 3,0 l'' -; 14 f 7.; 77 ".r: r 3b 20A #12 (2) DUPLEX RECEPT. l'' r r t' r - ; 3.0v'cr- 5c 20A SPARE :-. z f.,,f: 7a 15A #12 HP2C16 8.0: . . . . . , .` r; 9b 11C - 17 - i': 1 ir, '4 e : 13a 20A SPARE P., 044. fv, P° 0, V , 15b 20A SPARE ,-' ...\:; i.j. i'. i,r‘ rr• i:. r-A 17c 20A SPARE 1 c - r r v- 7,-,- . E r 2a 20A #12 AMS 4b 20A #12 (3) QUAD RECEPT. , k, ‘..i I: r:1-,:rpri 9.0 6c 20A SPARE $:„-- v,,I z? ;- 7' ;7,r s..-: ,,,,, tr. 8a 20A SPARE 10b 20A SPARE ' 12c 20A SPARE :. c c..., r (. t : !: rt r 14a ' - .. r t r •:,. z, r r 16b , ,, 1 c - r, 18c ir,--f:;- TOTAL 11 12 ELECTRICAL PANEL SCHEDULE Panel Designation 2B17 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 150A MCB 200A 208Y/120V, 3PH,4W 9-08-2E62 CASNE Location, bldg. Date Installed Feeder Size Fed From Revised Ckt Date Revised Job Number col. 11/26/2018 2817 9.08 2ND FLR B.7/17.3 TBD 2"C, 4#3/0, #6 GND 2C15/13,15,17 VIA 150A FILTER NEW PANEL 11.27.18 W5563002 Ckt Breaker Type I Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame Ph A la 20A #12 LED LIGHT FIXTURES 2.3 ',a:- 3b 20A #12 (2) QUAD RECEPT. r'7.•-r', r.: 6.0 "71-.:7 5c 20A #12 (3) QUAD RECEPT. ': r, .r.-- r: r...r7r,-;:r f: 9.0 7a 30A 3P #10 (1) L21-30 RECEPT. 9b #10 r :' '', C) - . , . . 11c #10 .77c- c -.7 ... r 17- z r,r. r 13a 30A 2P #10 (1) L6-30 RECEPT. c 1, 15b #10 ," r 17c 30A #10 (1) L5-30 RECEPT. - - "7, a ' c 7r ::::'• . , 19a 30A 2P #10 (1) L6-30 RECEPT. .„ . ,.. r•-4-r . ,. r.7- 21b #10 .,. . - r.;- :• 7 23c 30A #10 (1) L5-30 RECEPT. ,7r. „ , - o " r,.. 25a 45A #6 HEAT PUMP HP2B17 36 c.; 27b #6 . , ,;..-.7 Cl 36 , .. . . 29c #6 '.. 7 6,- o ' e-,-6-1. 36 31a 30A #10 (1) L5-30 RECEPT. 24 . ' r . . 33b 20A SPARE 7":- C" CC C"C C1 35c 20A SPARE :,,-- o ,- rs 37a 20A SPARE , `..: r..7:' f -- •_-;. a :: :r :7 39b 20A SPARE rr .7- 41c 20A SPARE '...c.": p•c. cc .c.c". 2a 20A #12 AMS r CI C" f r C1 ir,, 4b 20A #12 (3) QUAD RECEPT. - r 7r: r r-.. 9.0 - 6c 30A #10 (1) L5-30 RECEPT. -..r or- a CI r..Grg 8a 3P #10 (1) L21-30 RECEPT. 10b #10 -, r 12c #10 -r: i- Pr 14a 30A 2P #10 (1) L6-30 RECEPT. a qr. r r a " r r 16b #10 . - r r• i- c :- •-• , 18c 30A #10 (1) L5-30 RECEPT. 7'.rara crorr 20a 30A 2P #10 (1) L6-30 RECEPT. r 22b #10 -,- - - - 24c 30A #10 (1) L5-30 RECEPT. 7; r or 1:, . -^•. r :' r.4: c 26a 30A #10 (1) L5-30 RECEPT. c o r- ? 7 r. 7 r r 28b 30A #10 (1) L5-30 RECEPT. 7-rr r: r r rrr 30c 20A SPARE 32a 30A #10 (1) L5-30 RECEPT. _ r,,r r r 34b 20A SPARE ..77.r• r r r r,r,r zr7- r 36c 20A SPARE 17 of ri r,'• or't 38a 20A SPARE 40b 20A SPARE .i',.' e• en e r 42c 20A SPARE .-r. , r•pr el ,,, r, , TOTAL 62 51 45 7 11/26/2018 2C15-1 ELECTRICAL PANEL SCHEDULE Panel Designation 2C15-1 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer IEM "PIE" 225 AMP 480Y/277V, 3ph, 4w, 225A 9.08-2E112 CASNE Location, bldg. col. Date Installed Feeder Size Fed From short cirtcuit rating Revised Ckt Date Revised Job Number 9.08 2nd FLR C15(ELECTRICAL ROOM) 2D9-1/2abc 65,000 7,9,11 13,15,17 11.27.18 W5563002 Ckt Breaker Type Trip Wire Size Load Served Load Amps Location Frame I Ph A Ph B Ph C la TED 7 3P-30 30A 3P #10 HEAT PUMP 2613, 2612, 2611 ,, 1, , - -- 3b #10 _ 5c #10 14 P kr ,f SI - kr 14 7a TED 7 3P-30 30A #10 HEAT PUMP 2614 . 9b #10 . 11c #10 13a TED 7 3P-30 30A 3P SPARE .. : 15b 17c 19a TED 3P-30 30A 3P SPARE 21b 23c 14, 25a TED-1P 15 SPARE . Cr•-r Cf., . !.1 . '.$ ,. 14. ti . Ci 27b TED-1P 20 #10 HEAT PUMP 2A17 29c TED-1P 20 #10 HEAT PUMP 2A15, 2A19 ‘.., , 31a SPACE WITH HARDWARE . 33b SPACE WITH HARDWARE - 35c SPACE WITH HARDWARE 37a SPACE WITH HARDWARE .'13 _ - rli . 39b SPACE WITH HARDWARE 41c SPACE WITH HARDWARE 2a TED 7 3P-30 30A #10 HEAT PUMMP 2C15 (10.5 FLA) ._ ... . ,. .— FOR DATA CLOSET 4b #10 ,-,.'=;".2.-1.!.1. '4..4 l'- ii' -..-.1i4 - 4,2 6c #10 , 8a TED 7 3P-30 30A 3P #10 HEAT PUMP 2C14 10b #10 ,-.. -..,..,.. ,.-... . ..,-, 12c #10 .. . 14a TED 7 3P-30 30A 3P SPARE .. • ...7," . ;• .-- . i - '--, .,1 ',sr,— 4 :"..: 16b ,.. -:i.t-i'icl .... -,,,-.......- ..,,,- 18c 20a SPACE WITH HARDWARE ,I, r: , ., lj U:: 22b SPACE WITH HARDWARE ,,.,tr..71hti:. [k., : 44, •JA. 24c SPACE WITH HARDWARE , •..,,,..:.-1.-. 26a SPACE WITH HARDWARE If rit,KI.r: 28b SPACE WITH HARDWARE o , , 4 : • c .V.' Q . rQ ,..k. ..ii,....o, 30c SPACE WITH HARDWARE :.- f. ,;,-.;-• ,,,,, . 32a SPACE WITH HARDWARE 34b SPACE WITH HARDWARE : 1;1 • ti —.Lfri ' ,.1,.. •;:ir.'„1„) ._ kr :-.;-.1'..K.. ir ', kk 36c SPACE WITH HARDWARE -=- ,,,,,:--_:,ii. . 38a SPACE WITH HARDWARE . .....,....- ., , 1 ,,, , -,-,Z., ' .... 40b SPACE WITH HARDWARE L..., s....,,,,6,...... „, ,, -,tit,.,:r..' 42c SPACE WITH HARDWARE ,;.• ',I.', TOTAL / N „ ELECTRICAL PANEL SCHEDULE Panel Designation 2C15-2 Location, bldg. 9-08.2 col. C/15 Panel Type GE A SERIES TYPE AE Date Installed Main Bkr Rating 400A Feeder Size 3-500 MCM, 250 MCM, #2/0 Panel Rating 400A, 480Y/277V Fed From 2D10-1/(2,4,6) Ref. Dwg.No. 2E110 Revision Engineer Revised Ckt 8-24, 7-11 Date Revised 11.27.18 Job Number W5563002 Ckt Breaker Type Trip Wire Size Load Served Load Amps Location Frame Ph A Ph B Ph C la TED 100A 3P- #2 PNL BOARD 2C15-3 C/15 3b #2 ,- - - - r r ,,,, 71 • r. r , 5c #2 7a TED 175 3P 2/0 PNL BOARD 2C15 VIA XFMR -r r ••••= r . r r r , , C/15 9b 2/0 c r r.• r :;', f" r :4 r r r., t• rt-- ; r , r•• r - , 11c 2/0 13a SPACE W/ HARDWARE --,rre.,,z iP3nrr, 15b SPACE W/ HARDWARE 17c SPACE W/ HARDWARE tr • "4," 19a SPACE W/ HARDWARE , r • r r - rt 0 21b SPACE W/ HARDWARE r c t.,10 t, r nr - . • v. rtr 23c SPACE W/ HARDWARE r - r,- 25a SPACE W/ HARDWARE . r; • , r 0 1 27b SPACE W/ HARDWARE r 7 29c SPACE W/ HARDWARE c t ; • ; -c Li ''' 4 31a SPACE W/ HARDWARE - - (9,""kc ' n r 33b SPACE W/ HARDWARE r KM f, r - a - r • - r. r a; 35c SPACE W/ HARDWARE r f" Pr ,;-- -, 37a SPACE W/ HARDWARE -t r, - 39b SPACE W/ HARDWARE tot ....t. 41c SPACE W/ HARDWARE a - nr r 2a TED 70A PNL BRD 2C16 VIA XFMR C/16 4b #4 6c 8a TED 70A 3P SPARE 10b c.;- or r r; r r • ; r 7 r:i 12c r ^ r - r...- 14a TED 70A 3P SPARE 16b t-, ,,--. r t• rt r r 18c r r r• r C ""u r rttr.r 20a TED 70A 3P SPARE .tt" ;,, r 22b t,"-U,. r r .-:r r 1.t n t• 24c 26a SPACE W/ HARDWARE 28b SPACE W/ HARDWARE ft r 0 30c SPACE W/ HARDWARE t t, , t„ . r ;74: r,r ....; :. .,; t t, tr', 7.,r,r. 32a SPACE W/ HARDWARE 34b SPACE W/ HARDWARE 36c SPACE W/ HARDWARE r; E0 '00 ' r' r .! V ,, ',"'' 0,''•0. t..7 1 r r r r, 38a SPACE W/ HARDWARE 'fl-rt.' "F7=r-r•rr 40b SPACE W/ HARDWARE t:-. r,h.r. 42c SPACE W/ HARDWARE r r ..t a.. r. (.1, TOTAL 11/26/2018 2C15-2 / ELECTRICAL PANEL SCHEDULE Panel Designation 2C15-3 Panel Type Main Bkr Rating Panel Rating G.E. "A SERIES"TYPE AE G.E. TEL-100A-3P 480/Y277 100A Ref. Dwg.No. 9-08-2E12 Revision Engineer E CASNE Location, bldg. Column Date Installed Feeder Size Fed From Revised Ckt Date Revised Job Number 9-08.2 C/15 4#2 & 1#4 Panel 2C15-2/ 1,3,5 1,3,5 11.27.18 W5563002 Ckt Breaker Type I Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame Ph A la TED 20A #12 RC 2C15/R1,R2 ,:::::::::::: .'. -.. " - ..... 44 COL. C/11 3b TED 20A #12 RC 2C15/R3, R4 - ...... .14 COL. C/17 5c TED 20A SPARE 7a TED 20A #12 RC 2C15/R7,R8 .9gff.14i COL A-C / 19-20 9b TED 20A #12 RC 2C15/R9,R10 ::^v:ii::: COL A-C / 19-20 11c TED 20A #12 RC 2C15/R11,R12 44.4444,4«. ;ZI;;;i1M 4.44444444.: 'r4:'7,114,1;:,: COL. A-C / 19-20 13a TED 20A #12 RC 2C15/R13,R14 ithtf1::;:i iiii ' ' - COL. A-C / 19-20 15b TED 20A SPARE ,. 17c TED 20A SPARE 19a TED 20A SPARE 21b TED 20A SPARE ::;:,:;::•::z 23c TED 20A SPARE 25a TED 20A SPARE 11.mt4.44; t!:1!tiln11 27b TED 20A SPARE 29c TED 20A SPARE 31a SPACE W/ HARDWARE „...., . . . . 33b SPACE W/ HARDWARE 35c SPACE W/ HARDWARE 37a SPACE W/ HARDWARE 39b SPACE W/ HARDWARE NOR •Iiiiiiiiiiii. 41c SPACE W/ HARDWARE •*iiiii;IH4i iMiltii41.' 2a TED 20A 12 REST ROOM LIGHTS :71;aiiii:;:i 1: ... ::::::: COL C14 4b TED 20A SPARE6c TED 20A SPARE 8a TED 20A SPARE ....... 41;'71V4;;;; -4..t:.:11; !!Muir-f:T 10b TED 20A SPARE ..„. ... 12c TED 20A SPARE itfitfilt ni'thi 14a TED 20A SPARE 16b TED 20A SPARE 18c TED 20A #12 LIGHTING CONTROL PANEL 2C15 iiiiiia iiiiiiiiiii COL. C / 15 20a TED 20A SPARE iftn:::3Ri taltsFAni: 22b TED 20A SPARE muoi:m: 24c TED 20A SPARE Itm,”12, , 'r4V1r1.1r 26a TED 20A SPARE 28b TED 20A SPARE 30c TED 20A SPARE 32a SPACE W/ HARDWARE 34b SPACE W/ HARDWARE iliii! !F;5, iiglin 36c SPACE W/ HARDWARE 38a SPACE W/ HARDWARE 40b SPACE W/ HARDWARE -' - .. t ......;“ •.t.-,,n 42c SPACE W/ HARDWARE TOTAL \ ELECTRICAL PANEL SCHEDULE Panel Designation 2C15 Panel Type 400A Main Bkr Rating 300A MCB Panel Rating 208Y/120, 3PH,4W Ref. Dwg.No. Revision Engineer 9-08-2E62 CASNE Location, bldg. 9.08 2ND FLR col. C/15 Date Installed TBD Feeder Size (2) 2"C, 4#3/0, #3 GND Fed From 2C15-2 Revised Ckt Date Revised Job Number VIA 112.5KVA XFMR NEW PANEL 11.27.18 W5563002 Ckt Breaker Type Wire Size Load Served Load Amps Ph B 1 Ph C Location Frame Trip Ph A 150A 3P PANEL 2A15VIA POWER FILTER 2ND FLOOR A.5/12.2 3b #1/0 , 5c #1/0 ,,,,:..:,.,,,, :. ' •'.;'-',. 7a 100A 3P #1 PANEL 2B14VIA POWER FILTER 2ND FLOOR B.5/15 9b #1 11c #1 , 13a 150A 3P #1/0 PANEL 2617 VIA POWER FILTER ' ' ' ' ' ' ''' 2ND FLOOR A,5/17.3 15b #1/0 . r'' ,, ;:,4:!li::,:';i:',.' 17c #1/0 19a 21b 23c 25a 27b 29c 31a 33b '-..'• '':.'-':-Z , 35c 37a 39b ..., , 41c 2a 4b 6c 100A 3P #1 #1 #1 PANEL 2A15-1 VIA POWER FILTER 2ND FLOOR A.8/15.8 8a 10b 12c 150A 3P #1/0 #1/0 #110 PANEL 2C18 VIA POWER FILTER 2ND FLOOR C/18 14a 16b 18c 100A 3P #1 #1 #1 PANEL 2B15 VIA POWER FILTER 2ND FLOOR B.8/15.8 20a 22b 24c 26a 28b 30c 32a 34b 36c 38a 40b 42c ELECTRICAL PANEL SCHEDULE 11/26/2018 2C16 Panel Designation 2C16 Panel Type Main Bkr Rating Panel Rating IEM TYPE "PlB" 100A-3P TQD 100A, 208/120V, 3P, 4W Ref. Dwg.No. 9-08-2E61 Revision Engineer CASNE Location, bldg. 9-08.2 Column Date Installed Feeder Size 4#4 Fed From C- 16 Revised Ckt Date Revised Job Number PNL 2C15-2/2,4,6 VIA XFMR 11.0 11.27.18 W5563002 Ckt Breaker Type Trip Wire Size Load Served Load Amps Ph B 1 Ph C Location Frame I Ph A la THQB 20A #12 (3) DUPLEX RECEPT , t4 k. 0 44 t 't*':nt,t, ., kk ... ,, .. ''t11 *Pr COL. C - 16 3b THQB 20A #12 LOAD UNKNOWN 5c THOB 20A #12 (6) DUPLEX RECEPT ro rt ;`0041*. COL. A -14/17 7a T H Q B 20A #12 (2) DUPLEX RECEPT & 4-13.5W LED Lights = - $1.117 $ -, o r o t. Elevator Lobby 9b THQB 20A #12 LOAD UNKNOWN 11c THQB 20A #12 (1) DUPLEX - DED, - DAS RECEPT 1. r o o o ,* o , r I 21C15 13a HOB 20A #12 LOAD UNKNOWN 15b THQB 20A #12 (1/2) 4-PLEX RECEPT.- COFFEE POTS -. = o ,, o : * c ; 1 A/11 17c THQB 20A #12 (1/2)4-PLEX RECEPT. - COFFEE POTS o I o I,' A111 19a THQB 20A #12 (1) DUPLEX RECEPT, - MICROWAVE t's evo , e: of . A/11 21b THQB 20A SPARE ); Q P P 0, r 0 23c THQB 20A SPARE :Oz.,P0 .ortsrf 25a THQB 20A SPARE f. t, ttr:r ttr t ot- 27b SPACE WITH HARDWARE - 29c SPACE WITH HARDWARE 31a SPACE WITH HARDWARE oroo$ aoo --r 33b SPACE WITH HARDWARE o o . o 00000 NA kk kk N. 35c SPACE WITH HARDWARE tAl 04 ft Vt 0 r 4 37a SPACE WITH HARDWARE • o tto$ „.., ,..-. •to-! or ,f,4•0.44 39b SPACE WITH HARDWARE k f+k 1 4) 0 41c SPACE WITH HARDWARE 2a GFI-THQB 20A #12 (4) DUPLEX RECEPT -RESTROOMS AND WTR CLR. ,roort .. of o -17 . COL. C - 14 4b THQB 20A #10 (3) DUPLEX AND (1) 4-PLEX RECEPTS. 1 o o , o COL C-D/15-18 6c THQB 20A #10 (3) DUPLEX IN CORRIDOR AND (1) POWER POLE oro€ o oroot „ , «, ... COL. C- 18 8a THQB 20A #12 (6) DUPLEX RECEPT ' ''' '', l''' "r` r " COL. A - 17/19 10b THQB 20A #12 (7) DUPLEX RECEPT . 0 ; o o .. et. r, l' '" 4' rl t; V4 i, it I. .14 COL. A - 17/19 12c THQB 20A #12 (4) DUPLEX RECEPT SI Pe rt 0 01 COL. A - 15/17 14a THQB 20A #12 (4) DUPLEX RECEPT k " " ' " ' 't ' t COL. A - 12/14 16b THQB 20A SPARE - r, r. Is P • 0 " P 18c THQB 20A SPARE .:,cro roorf 20a THQB 20A SPARE r $ oef -Pert\--et,r er: or 22b THQB 20A SPARE -noon t-,•: V ;"J . never 24c THQB 20A 26a THQB 20A SPARE o o . 0: 0 --1 28b THQB 20A (1) DUPLEX 0 o , o * o o . t: q , n p 42" AFF B/14.5 30c SPACE WITH HARDWARE 32a SPACE WITH HARDWARE 34b SPACE WITH HARDWARE + A. N .,.. ka• -; :I $te II irk .A k.; 1N. I+ 1 r 36c SPACE WITH HARDWARE i St .A. kk AA AAA ko A lk. 38a SPACE WITH HARDWARE $ororf\:-toror 40b SPACE WITH HARDWARE 42c SPACE WITH HARDWARE ,,,* CPO ;,.•OPP$ TOTAL ELECTRICAL PANEL SCHEDULE Panel Designation 2C18 Panel Type Main Bkr Rating Panel Rating Ref, Dwg.No. Revision Engineer 100A MCB 150A 208Y/120V, 3PH,4W 9-08-2E62 CASNE 11/26/2018 2C18 Location, bldg. 9.08 2ND FLR col. C18 Date Installed TBD Feeder Size 1-1/2"C, 4#1/0, #6 GND Fed From 2C15/8,10,12 Revised Ckt Date Revised Job Number VIA 150A FILTER NEW PANEL 11.26.18 W5563002 Ckt Breaker Type Wire Size Load Served Load Amps Location Frame Trip Ph A Ph B Ph C la 20A #12 LED LIGHT FIXTURES 13.5 r 3b 20A #12 AMS 5c 20A #12 (4) QUAD RECEPT. - . 6-1 • r 4- r i f 12.0 7a 20A #12 (4) QUAD RECEPT. 12.0 -7 ' t - t • • - ,' t.: 9b 20A #12 (1) QUAD RECEPT. 0: t: -7' 3 3 C r r3 r 1 1 c 30A #10 (1) L5-30 RECEPT. 7 /' Pc rr r7 41C r 13a 3P PANEL 2A17 15b #4 _ 17c #4 7 " t r r ri: 19a 20A #12 (1) QUAD RECEPT. 3 ,,r r 21b 20A #12 (1) QUAD RECEPT. - f ' - n 3 , '.- 23c 20A #12 (1) QUAD RECEPT. - - - , 0.1- 7 ':0.7 r3 25a 20A SPARE 27b 20A SPARE r1 ' / - 4" 29c 20A SPARE ' r :-. r 0.; t - c :.-• r : 31a 20A SPARE r i0 , C ::: - r 33b 20A SPARE - r rrr' 70 7 35c 20A SPARE 37a 20A SPARE :r-r-r01 c- r -t 39b 20A SPARE 41c 20A SPARE -0. r rt- r • r - t00- 7 2a 20A SPARE 7 7 Cr " 4 .... . "7 4b 20A #12 (4) QUAD RECEPT. • .7. r' r.'. 0 _ 12.0 :-- r 0- r 6c 20A #12 (3) QUAD RECEPT. - r :0 r: 7 c - rr r r 9.0 8a 20A #12 (3) QUAD RECEPT. 9 r 10b 20A #12 (1) QUAD RECEPT. -, r 7 cr 3 12c 20A #12 (1) QUAD RECEPT. — 74 7 '74 74- 43 14a 20A #12 (1) QUAD RECEPT. 3 , ci 16b 20A SPARE - , r r 18c 20A SPARE q fi r r r.0 Id 7 .."C a 20a 20A SPARE tr. f !...... r v C,• 22b 20A SPARE r'' - - — ,- "77-7 - r -- - 24c 20A #12 HEAT PUMP HP2A19 13 26a 60A #4 PANEL 2A17-1 H r '. 7 r C i C 4 28b #4 30c 32a 20A SPARE r , t,i0t. t - r „. r 7, r 34b 20A SPARE t0i 1'1- Cr ,, 36c 20A SPARE -, 7 .., , 38a 35A #8 HEAT PUMP HP2B19 24 r .• r r 7 C 7 4 -.- 40b #8 7 !, ' r 24 - ' 42c #8 7 rt" 7, fr fi 44 r- r 24 TOTAL 1 651 451 671 9-08.2 Tenant Improvement 181-093.350 November 27, 2018 APPENDIX A PANEL SCHEDULES Boeing #: W5563002 Appendix A — Panel Schedules -'1 71 ' -1 ' . 1 _ ELF! 0175 APPENDIX A — PANEL SCHEDULES PAGE - 1 RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER / ELECTRICAL PANEL SCHEDULE Panel Designation 2A15-1 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 60A MCB 100A,208Y/120V, 3PH,4W 9-08-2E61 CASNE 1/26/2018 2A15,1 Location, bldg. 9.08 2ND FLR col. A.8/15.5 Date Installed TBD Feeder Size 1-1/2"C, 4#1, #8 GND Fed From 2C15/2,4,6 Revised Ckt Date Revised Job Number VIA 100A FILTER NEW PANEL 11.27.18 W 5563002 Ckt Breaker Type Trip Wire Size Load Served Load Amps Location Frame i Ph A Ph B Ph C la 20A #12 LED LIGHT FIXTURES 6.0 , v C' " t` f :" r 3b 20A #12 AMS -,- ir-- -./ ....,. — 5c 30A #10 (1) L5-30 RECEPT. - r.r, pc t - r r . 24.0 7a 20A SPARE cr r.. 9b 20A SPARE - - c:r -1 . - - r 7 C 1 1 c 20A SPARE r: - a -;.- .rc.- f r 13a 20A SPARE 15b 20A SPARE - r ,2 C l',7 " ' r .'"' ?: 17c 20A SPARE - r Pc 2a 20A #12 (4) QUAD RECEPT. 12.0 ::•,.;. :,,..r..,''; 4b 20A #12 (3) QUAD RECEPT. ,, '1, ' ' Pr 0. 9.0 ,. , • t .,r.r.-F, -- 6c 20A SPARE vr t5 .r 8a 20A SPARE -zr r :: r.. n r' 7' 7' 10b 20A SPARE . . ir ..Y ':•A -: Dr X1 ..-,i, 12c 20A SPARE ., :,,,':- 0 (I' ' C. 14a 35A 3P #8 HEAT PUMP HP2B16 25 -,....-.--.:-I.pir °. :. 16b #8 25 18c #8 P 7 r 0. . f';' tt r. 25 TOTAL 431 34 49 r ELECTRICAL PANEL SCHEDULE 11/26/2018 2815 Panel Designation 2A15 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 100A MCB 150A,208Y/120V, 3PH,4W 9-08-2E61 CASNE Location, bldg. 9.08 2ND FLR col. A.5/15.5 Date Installed TBD Feeder Size 1-1/2" 4#1/0, #6GND Fed From 2C15/1,3,5 Revised Ckt Date Revised Job Number VIA 150A FILTER NEW PANEL 11.26.18 W5563002 Ckt Breaker Type I Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame Ph A la 20A #12 LED LIGHT FIXTURES 3.0 ::. -;7..r:- 3b 20A #12 AMS , 5c 30A 2P #10 (1) L6-30 RECEPT. 7a #10 9b 30A #10 (1) L5-30 RECEPT. ,-,.-:.. ,or- a 11C 30A #10 (1) L5-30 RECEPT. . 13a 45A #6 HEAT PUMP HP2A15 3578 15b #6 ... 35.8 . ... 17c #6 .. ..-zf,':- , r ..., r 35.8 2a 20A #12 (4) QUAD RECEPT. 12.0 ' `.''. ' ',;.:, ,,.. , 4b 30A 2P #10 (1) L6-30 RECEPT. . '...', r r 6c #10 , 8a 30A #10 (1) L5-30 RECEPT. 7 1..,.. . r.,,,-.;.... , ,. -1, o k. r r 10b 30A #10 (1) L5-30 RECEPT. ' .-! r •.`": !- r:` 12c 20A #12 (1) QUAD RECEPT. 1,-. ;.- r-.., t °-, c.'!:: r If 3 14a 40A 3P #8 SPARE -,:r c77 r: r, 11 ,',`,.' r: r - r 16b #8 SPARE ,' ';'• •.. ...'), "'?..' 18c #8 SPARE ,- : c- r. t' 1, TOTAL 51 36 39 \ ELECTRICAL PANEL SCHEDULE Panel Designation 2A17-1 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 60A MCB 100A,208Y/120V, 3PH,4W 9-08-2E62 CASNE 1/26/2018 2A17-1 Location, bldg. 9.08 2ND FLR cal. A.9/18 Date Installed TBD Feeder Size 1-1/4"C, 4#4, #8 GND Fed From 2B14/18,20,22 Revised Ckt Date Revised Job Number VIA 60A FILTER NEW PANEL 11.27.18 W5563002 Ckt Breaker Type Wire Size Load Served Load Amps Location Frame I Trip Ph A Ph B Ph C la 20A #12 LED LIGHT FIXTURES 2.3 z. 7 r: r ' 3b 20A #12 (3) DUPLEX RECEPT. : .$' a.- r$ 4.5 5c 20A SPARE 7a 20A 3P #10 HEAT PUMP HP2B18 16.0 r - r$$ 9b #10 - r. -" - 16 11c #10 - r r c r — '.; s $ 16 13a 20A SPARE ;$ f: r ,r,r 7 t 15b 20A SPARE 17c 20A SPARE r $, 1. 2a 20A #12 (3) DUPLEX RECEPT. 45 4b 20A SPARE ,;,. . 1 D :' 6c 20A SPARE , *: r, ,.-- r,' rr.:., 8a 20A SPARE $$- r c r. n-r ;-$.•$.1 10b 20A SPARE . ,... s. - r ' r 12c 20A SPARE ,-.. r. 71 r'';': C.' 14a 20A SPARE 16b 20A SPARE -'6 r. r$4 18c 20A SPARE z$-:: GC. c. , C : n r. I TOTAL 23 211 16 ELECTRICAL PANEL SCHEDULE 11/26/2018 2A17 Panel Designation 2A17 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 60A MCB 100A,208Y/120V, 3PH,4W 9-08-2E62 CASNE Location, bldg. Date Installed Feeder Size Fed From Revised Ckt Date Revised Job Number col. 9.08 2ND FLR A.5/18 TBD 1-1/4"C, 4#4, #8 GND 2B14/13,15,17 VIA 60A FILTER NEW PANEL 11.27.18 W 5563002 Ckt Breaker Type I Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame Ph A la 20A #12 LED LIGHT FIXTURES 2.3 r - 5 — Li 7 r • 3b 30A #10 (1) L5-30 RECEPT. - r— r -- - • , 5c 20A SPARE 7a 35A #8 HEAT PUMP HP2A18 25 , r • - r c,,, - - - z- 9b #8 25 e . , ' ' '.• r ''' 110 #8 - ' r,r r ... r • -- $ 25 13a 20A SPARE i'..• - n,- - v ,. ', 15b 20A SPARE 17c 20A SPARE 2a 20A #12 (3) QUAD RECEPT. 9.0 r , ..7,,, 4b 20A #12 (1) QUAD RECEPT. 0 a v " e, . „ ... .. . 6c 20A SPARE 7.7 8a 20A SPARE r -r c - 10b 20A SPARE - 1.7' 12c 20A SPARE 7- - v- 0 r r, - 14a 20A SPARE 16b 20A SPARE 18c 20A SPARE 0 • it, , s4 ': rts zs CJ ' .0 i r ,•_ ..-,, F TOTAL 37 28 25 ELECTRICAL PANEL SCHEDULE Panel Designation 2B14 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 60A MCB 100A,208Y/120V, 3PH,4W 9-08-2E61 CASNE Location, bldg. Date Installed Feeder Size Fed From Revised Ckt Date Revised Job Number col. L11/26/2018 2814 9.08 2ND FLR B14.5 TBD 1-1/2"C, 4#1, #8 GND 2C15/7,9,11 VIA 100A FILTER NEW PANEL 11.26.18 W5563002 Ckt Breaker Type Wire Size Load Served Load Amps Location Frame Trip Ph A Ph B Ph C la 20A #12 LED LIGHT FIXTURES 4.0 3b 20A #12 AMS 5c 20A SPARE ' r .'" ':''. I 7a 35A #8 HEAT PUMP HP2B15 24 .'r•r r i t. i.• ;! r,:.:: --. 9b #8 : r.: ,','',7-..1 24 .-. ,...!,. 11c #8 7' !,"r.k, .af- a': i 24 13a 20A SPARE C.,' l' r i 7 fl C n r- 15b 20A SPARE R ,' 17c 20A SPARE r' r•P' 0 r 7 r := f 2a 20A #12 (4) QUAD RECEPT. 12.0 4b 30A #10 (1) L5-30 RECEPT. ' 6c 20A #12 (1) QUAD RECEPT. r -,i•• r tf r 'r t 3.0 8a 20A SPARE ,-- 7' t• r--,.-.7-t- 10b 20A SPARE iArr- f 12c 20A SPARE - z 14a 20A SPARE r 16b 20A SPARE 18c 20A SPARE TOTAL 40 24 27 ELECTRICAL PANEL SCHEDULE Panel Designation 2B15 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 60A MCB 100A,208Y/120V, 3PH,4W 9-08-2E62 CASNE 11/26/2018 2815 Location, bldg. 9.08 2ND FLR col. B.8/16 Date Installed TBD Feeder Size 1-1/2"C, 4#1, #8 GND Fed From 2C15/14,16,18 Revised Ckt Date Revised Job Number VIA 100A FILTER NEW PANEL 11.27.18 W5563002 Ckt Breaker Type Trip Wire Size Load Served Load Am s Location Frame I Ph A Ph B 1 Ph C la 20A #12 LED LIGHT FIXTURES 3.0 -.:' r :--; .'.. '..• ikk• 3b 20A #12 (2) DUPLEX RECEPT. ': • r'' rt 3.0 5c 20A SPARE "; - !I,' 0 7a 15A #12 HP2C16 8.0 r , t'k' k ii t., . 9b r : • n :' '-'i. 11C 13a 20A SPARE ,. .. .. 15b 20A SPARE - r r ri 17c 20A SPARE . , r ,s, 2a 20A #12 AMS •tl r , - 4b 20A #12 (3) QUAD RECEPT. .; t,4 1 p ',. 17,' it n .1/41 r, 1.• 41, , ,P , 6c 20A SPARE 7 - rp r' 8a 20A SPARE -t!‘!' 10b 20A SPARE - r 7 C.:. 12c 20A SPARE - c , f ,-'' CI rf ,:"41 ;[ 14a }-r-ri r4 16b 18c • 7 rk.1" TOTAL 11 12 ELECTRICAL PANEL SCHEDULE Panel Designation 2B17 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 150A MCB 200A 208Y/120V, 3PH,4W 9-08-2E62 CASNE 11/26/2018 2817 Location, bldg. 9.08 2ND FLR col. B.7/17.3 Date Installed TBD Feeder Size 2"C, 4#3/0, #6 GND Fed From 2C15/13,15,17 Revised Ckt Date Revised Job Number VIA 150A FILTER NEW PANEL 11.27.18 W5563002 Ckt Breaker Type Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame Ph A 1 a 20A #12 LED LIGHT FIXTURES 2.3 - c:-, 3b 20A #12 (2) QUAD RECEPT. 7, - c - 0 6.0 5c 20A #12 (3) QUAD RECEPT. ',-. ,,:‘ 7 0 1 f" t'' :7 7 9.0 7a 30A 3P #10 (1) L21-30 RECEPT. 9b #10 - 11c #10 13a 30A 2P #10 (1) L6-30 RECEPT. 15b #10 , - 17c 30A #10 (1) L5-30 RECEPT. 7 ' .., 19a 30A 2P #10 (1) L6-30 RECEPT. .t• r cr. r 7 n 1 21b #10 - :'• 7 n , r r 23c 30A #10 (1) L5-30 RECEPT. - c ..' c r ''r r; `.."r. t 25a 45A #6 HEAT PUMP HP2B17 36 t., 0 - tl 4 , r; r t, 27b #6 r: c 36 29c #6 -..t ,.-• t 36 31a 30A #10 (1) L5-30 RECEPT. 24 tr• c - 7 f ,. t1, "'"' it"' i., 33b 20A SPARE c t' " 35c 20A SPARE - c . 37a 20A SPARE 7:.c,c c ..,1 r r 7 7 39b 20A SPARE • •-• or, r- , 7c,- 41c 20A SPARE 2a 20A #12 AMS c r .7-?..r4 t . _ ..f. 17 ! r2 r 4b 20A #12 (3) QUAD RECEPT. . ., ' 9.0 6c 30A #10 (1) L5-30 RECEPT. 8a 3P #10 (1) L21-30 RECEPT. ,.','..' ;'..7-,, c' 10b #10 ' ' c7,• c.rc 12c #10 ;...-.:7.t'.- l' r5 tf..r ..:- r' 14a 30A 2P #10 (1) L6-30 RECEPT. . r c.f tr. - 16b #10 . , .. ..., 18c 30A #10 (1) L5-30 RECEPT. , c 20a 30A 2P #10 (1) L6-30 RECEPT. Fr , v.11 c, ci r r 22b #10 . . . . 24c 30A #10 (1) L5-30 RECEPT. 26a 30A #10 (1) L5-30 RECEPT. :. c r7 t , .--r 28b 30A #10 (1) L5-30 RECEPT. 7:t,"'t" 7 rt, r r• f 30c 20A SPARE ' t-- cf. c. 32a 30A #10 (1) L5-30 RECEPT. c - c,i, t- 7 fr .c-,r_' L., . . ... E 34b 20A SPARE , '7,r.E-- rt ...-- ,,,, ,... . 36c 20A SPARE cc. c - c r :.. 38a 20A SPARE ,-.”:::, •••••1';.ri,,F n.:14.t. L44,4:4i 40b 20A SPARE 77c.c 7. r r,”-,.. v -...c 42c 20A SPARE TOTAL J 621 51 45 11/26/2018 2C15-1 ELECTRICAL PANEL SCHEDULE Panel Designation 2C15-1 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer IEM "PIE" 225 AMP 480Y/277V, 3ph, 4w, 225A 9.08-2E112 CASNE Location, bldg. 9.08 2nd FLR col. C15(ELECTRICAL ROOM) Date Installed Feeder Size Fed From 2D9-1/2abc short cirtcuit rating 65,000 Revised Ckt 7,9,11 13,15,17 Date Revised Job Number 11.27.18 W5563002 Ckt Breaker Type Frame Trip Wire Size Load Served Ph A Load Amps PhB PhC Location la 3b 5c TED 3P-30 30A 3P #10 #10 #10 HEAT PUMP 2B13, 2B12, 2B11 7a 9b 11c TED 3P-30 30A 3P #10 #10 #10 HEAT PUMP 2B14 I 13a 15b 17c TED 3P-30 30A 3P SPARE 1 I , 19a 21b 23c TED 3P-30 30A 3P SPARE :). 25a TED-1P 15 SPARE • 27b TED-1P 20 #10 HEAT PUMP 2A17 29c TED-1P 20 #10 HEAT PUMP 2A15, 2A19 31a SPACE WITH HARDWARE 33b SPACE WITH HARDWARE 35c SPACE WITH HARDWARE 37a SPACE WITH HARDWARE 39b SPACE WITH HARDWARE 41c SPACE WITH HARDWARE 2a TED 3P-30 3P #10 HEAT PUMMP 2C15 (10.5 FLA) FOR DATA CLOSET 4b #10 r:-.,,,,,--:, . !'-, ,.'1,,441,.! .., , ----- .. -.4., : ::...,,:., 6c #10 Fr7.:;.-:,•.:;'. :----,,7_,:l. 7-, -.:-..,.. 8a TED 3P-30 30A 3P #10 HEAT PUMP 2C14 10b #10 . ris -, _ 12c #10 14a TED 3P-30 30A 3P SPARE b,i',-,k;!" 16b - 18c 20a SPACE WITH HARDWARE 4.o :!(..H,,,•L'; -,.:: =,f t 1,., > •p,D 22b SPACE WITH HARDWARE ,'L;44'',:- 24c SPACE WITH HARDWARE 26a SPACE WITH HARDWARE .-,•-,:-,q1.,:g.t.-:',. :_,!.::: ,r:---.• l' ,. 28b SPACE WITH HARDWARE ...'•;.'-''':-.. ,44 - i.--- 0 , 30c SPACE WITH HARDWARE , • ',.- '• .1" ,•,4 32a SPACE WITH HARDWARE , . ._.•,., ,.,:.; ...,'. ,,.,I..14,, 34b SPACE WITH HARDWARE 36c SPACE WITH HARDWARE 4-..i„, C., • . 17 PL, L7 --,',.Li.r.., ',..- 10 38a SPACE WITH HARDWARE .;.,:: 2. .= L 2, , ;. 40b SPACE WITH HARDWARE ,;,..,41, 1. !,iff 42c SPACE WITH HARDWARE -:',..v, ti!":': '13 ti"-Ai, TOTAL N 4./ ELECTRICAL PANEL SCHEDULE Panel Designation 2C15-2 Location, bldg. 9-08.2 col. C/15 Panel Type GE A SERIES TYPE AE Date Installed Main Bkr Rating 400A Feeder Size 3-500 MCM, 250 MCM, #2/0 Panel Rating 400A, 480Y/277V Fed From 2D10-1/(2,4,6) Ref. Dwg.No. 2E110 Revision Engineer Revised Ckt Date Revised Job Number 8-24, 7-11 11.27.18 W5563002 Ckt Breaker Iype # Trip Wire Size Load Served Load Am.as Location Frame Ph A Ph B Ph C la TED 100A 3P #2 PNL BOARD 2C15-3 'It c0';.' C/15 3b #2 r- c ' T1, : t'Y ri-A. 5c #2 t f, 7a TED 175 2/0 PNL BOARD 2C15 VIA XFMR -:=0",r•V.-?.' ,...,re.ri, C/15 9b 2/0 t- ..' "' r .T.T. 7 r t '..,"..f 11c 2/0 cr: 0- rt- r rn.r .=r, r: r r -,er, r 13a SPACE W/ HARDWARE -,--•;.. r - 4- r ' 15b SPACE W/ HARDWARE r, •r•- rt, r ,. r" r.,. ,- c 17c SPACE W/ HARDWARE 19a SPACE W/ HARDWARE -4, ',', tt..;- t • t10 21b SPACE W/ HARDWARE 23c SPACE W/ HARDWARE 77 r ---- rt 25a SPACE W/ HARDWARE r - r ;,- r. .;; - 27b SPACE W/ HARDWARE r r r .-. ''''' r--. !'' 29c SPACE W/ HARDWARE t . ;.-• rt- -14,- 31a SPACE W/ HARDWARE -,, * ;- I; ) ,. r1 n' :;,.t • o4; F"' 33b SPACE W/ HARDWARE ,,- r .717 35c SPACE W/ HARDWARE 37a SPACE W/ HARDWARE 39b SPACE W/ HARDWARE it c t-t 41c SPACE W/ HARDWARE 4,, r i'.• c . ,.. t7..-t i,*.- 2a TED 70A PNL BRD 2C16 VIA XFMR C/16 4b #4 i. t) r r n n 6c #4 r . r, r 8a TED 70A 3P SPARE lob -- - - 12c 14a TED 70A SPARE r 16b 18c r 1.,..t t 20a TED 70A 3Pr SPARE 22b 0 - - • 24c 26a SPACE W/ HARDWARE t. kt 4 r ', 28b SPACE W/ HARDWARE 2 ff i5 r 55 n, r 30c SPACE W/ HARDWARE t t-t - • t- r r- - C' '1 r " 32a SPACE W/ HARDWARE -. 34b SPACE W/ HARDWARE ni: C n3 36c SPACE W/ HARDWARE r n' n r n - r''' -' 38a SPACE W/ HARDWARE r '..'" . -rrr,'• 40b SPACE W/ HARDWARE 42c SPACE W/ HARDWARE ' f; ' f' TOTAL 11/26/2018 2C15-2 ELECTRICAL PANEL SCHEDULE Panel Designation 2C15-3 Panel Type Main Bkr Rating Panel Rating G.E. "A SERIES7YPE AE G.E. TEL-100A-3P 480/Y277 100A Ref. Dwg.No. 9-08-2E12 Revision Engineer E CASNE Location, bldg. Column Date Installed Feeder Size Fed From Revised Ckt Date Revised Job Number 9-08.2 C/15 4#2 & 1#4 Panel 2C15-2/ 1,3,5 1,3,5 11.27.18 W5563002 Ckt Breaker Type Trip Wire Size Load Served Load Amps Ph B 1 Ph C Location Frame 1 Ph A la TED 20A #12 RC 2C15/R1,R2 =ma; -.....*".. mmmw. .,....--:. COL, C/11 3b TED 20A #12 RC 2C15/R3, R4 EMU !MIEN COL, C/17 5c TED 20A SPARE "gill * i2 Min 7a TED 20A #12 RC 2C15/R7,R8 u1;1;:.: ; ,,,":: ': ; - . : ;.., COL. A C / 19-20 9b TED 20A #12 RC 2C15/R9,R10 ..'"A:-`11 COL. A-C / 19-20 11c TED 20A #12 RC 2C15/R11,R12 III 1 114 ii ii#iiii COL. A-C / 19-20 13a TED 20A #12 RC 2C15/R13,R14 1!,:iiq :::::;;;;„„1. i:m m; : ;;;,..;;; COL. A-C / 19-20 15b TED 20A SPARE mmtlt::: 17c TED 20A SPARE 19a TED 20A SPARE lniiml ::immm 21b TED 20A SPARE mmmg: 23c TED 20A SPARE 25a TED 20A SPARE 27b TED 20A SPARE .:..4.:, „:... 29c TED 20A SPARE 31a SPACE W/ HARDWARE 33b SPACE W/ HARDWARE 35c SPACE W/ HARDWARE 37a SPACE W/ HARDWARE 39b SPACE W/ HARDWARE "giRTIT !HUMP 41c SPACE W/ HARDWARE ,...a.: .,„.. ,,..... 2a TED 20A 12 REST ROOM LIGHTS 'iiiiiifliii " ' ' -; COL C14 4b TED 20A SPARE 6c TED 20A SPARE 80 TED 20A SPARE 10b TED 20A SPARE 12c TED 20A SPARE 14a TED 20A SPARE 16b TED 20A SPARE 18c TED 20A #12 LIGHTING CONTROL PANEL 2C15 iiiiiiWiiiiiiiiiii COL. C / 15 20a TED 20A SPARE liri'i Ai! P , 22b TED 20A SPARE 24c TED 20A SPARE 26a TED 20A SPARE 28b TED 20A SPARE 30c TED 20A SPARE ungt==== mmutu:;;;;n2147. 32a SPACE W/ HARDWARE 34b SPACE W/ HARDWARE . - 36c SPACE W/ HARDWARE 38a SPACE W/ HARDWARE 40b SPACE W/ HARDWARE 42c SPACE W/ HARDWARE tratitift 44 ifiS141n TOTAL ELECTRICAL PANEL SCHEDULE Panel Designation 2C15 Panel Type 400A Main Bkr Rating 300A MCB Panel Rating 208Y/120, 3PH,4W Ref. Dwg.No. Revision Engineer 9-08-2E62 CASNE Location, bldg. 9.08 2ND FLR col. C/15 Date Installed TBD Feeder Size (2) 2"C, 4#3/0, #3 GND Fed From 2C15-2 Revised Ckt Date Revised Job Number VIA 112.5KVA XFMR NEW PANEL 11.27.18 W5563002 Ckt Breaker Type I Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame Ph A 150A 3P PANEL 2A15VIA POWER FILTER 2ND FLOOR A.5/12.2 3b #1/0 5c #1/0 7a 100A 3P #1 PANEL 2B14VIA POWER FILTER 2ND FLOOR B.5/15 9b #1 . ,: - 11c #1 13a 150A 3P PANEL 2B17 VIA POWER FILTER 2ND FLOOR A.5/17.3 15b #1/0 17c #1/0 ,. . L • :' 19a 21b . --- 23c 25a 27b 29c 31a 33b 35c 37a 39b 41c 2a 4b 6c #1 100A #1 3P #1 PANEL 2A15-1 VIA POWER FILTER 2ND FLOOR A.8/15.8 8a 10b 12c #1/0 150A #1/0 3P #1/0 PANEL 2C18 VIA POWER FILTER 2ND FLOOR C/18 14a 16b 18c 20a 100A 3P #1 #1 #1 PANEL 2B15 VIA POWER FILTER = 2ND FLOOR B.8/15.8 22b 24c 26a 28b 30c 32a 34b 36c 38a 40b 42c f ELECTRICAL PANEL SCHEDULE r 11/26/2018 2C16 Panel Designation 2C16 Panel Type Main Bkr Rating Panel Rating IEM TYPE "PIB" 100A-3P TQD 100A, 208/120V, 3P, 4W Ref. Dwg.No. 9-08-2E61 Revision Engineer CASNE Location, bldg. Column Date Installed Feeder Size Fed From Revised Ckt Date Revised Job Number 9-08.2 C- 16 4#4 PNL 2C15-2/2,4,6 VIA XFMR 11.0 11.27.18 W5563002 Ckt Breaker Type Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame I Ph A 1 a THQB 20A #12 (3) DUPLEX RECEPT r ; t: r } •± . '( COL. C - 16 3b THQB 20A #12 LOAD UNKNOWN 4 ±:X i r ; r I, 4`544 : 0: 0. 5c THQB 20A #12 (6) DUPLEX RECEPT r ir r , s u , a, COL. A -14/17 7a THQB 20A #12 (2) DUPLEX RECEPT & 4-13.5W LED Lights a' _ 14 .. (s r' Elevator Lobby 9b THQB 20A #12 LOAD UNKNOWN , o :0 ` 0' C a. 11c THQB 20A #12 (1)DUPLEX -DED.-DASRECEPT .:icrr c rr; 21C15 13a THQB 20A #12 LOAD UNKNOWN. i r sr r: is 'i r' 15b THQB 20A #12 (1/2) 4-PLEX RECEPT: COFFEE POTS a i:. <; A/11 17c THQB 20A #12 (1/2) 4-PLEX RECEPT. - COFFEE POTS . # + + A/11 19a THQB 20A #12 (1) DUPLEX RECEPT. - MICROWAVE 10 t is _ r n r N11 21b THQB 20A SPARE • "='r, 23c THQB 20A SPARE o_;� 25a THQB 20A SPARE •r nrt .%ir 27b SPACE WITH HARDWARE ,, 4: ; 1.; 0 V t s} 1' I. 29c SPACE WITH HARDWARE ` {? " n ° r. t 31a SPACE WITH HARDWARE "`"0 r '' ` .r 33b SPACE WITH HARDWARE ''r' 35c SPACE WITH HARDWARE : i' ; 4, Pt f 37a SPACE WITH HARDWARE 39b SPACE WITH HARDWARE ' r' "" c e r ' " f' 41c SPACE WITH HARDWARE 0..4, 0"f• "nnr:+:rr:c. 2a GFI-THQB 20A #12 (4) DUPLEX RECEPT -RESTROOMS AND WTR CLR. r. %x } " r: • j COL. C - 14 4b THQB 20A #10 (3) DUPLEX AND (1) 4-PLEX RECEPTS. . , ?' R COL. C D/15 18 6c THQB 20A #10 (3) DUPLEX IN CORRIDOR AND (1) POWER POLE ; n ; r 1, ' µ # COL. C- 18 8a THQB 20A #12 (6) DUPLEX RECEPT "` rt ",r °1 'r COL. A - 17/19 10b THQB 20A #12 (7) DUPLEX RECEPT . r;, ' ^;; !' r COL. A- 17/19 12c THQB 20A #12 (4) DUPLEX RECEPT „ ` COL. A - 15/17 14a THQB 20A #12 (4) DUPLEX RECEPT £':, COL. A 12/14 16b THQB 20A SPARE 18c THQB 20A SPARE 20a THQB 20A SPARE e- or cesr r.s nt,vnr%t t+x-e++.t 22b THQB 20A SPARE n n ;' ti r n I.a 24c THQB 20A SPARE "0 4, ...- "; 0 zs 26a THQB 20A SPARE .. 0; { s[rir.rrr- of ;- ex r 28b THQB 20A (1) DUPLEX rs y R r r `: iz r 42" AFF B/14.5 30c SPACE WITH HARDWARE c4. a %: c ,, r, i 32a SPACE WITH HARDWARE s' r r 47 r t ; . t 34b SPACE WITH HARDWARE ^ r , r s. 36c SPACE WITH HARDWARE o ; 44 4 38a SPACE WITH HARDWARE 40b SPACE WITH HARDWARE a rsr 42c SPACE WITH HARDWARE , a 1 a;• _: a : �t x TOTAL ELECTRICAL PANEL SCHEDULE Panel Designation 2C18 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 100A MCB 150A 208Y/120V, 3PH,4W 9-08-2E62 CASNE 11/26/2018 2C18 Location, bldg. 9.08 2ND FLR col. C18 Date Installed TBD Feeder Size 1-1/2"C, 4#1/0, #6 GND Fed From 2C15/8,10,12 Revised Ckt Date Revised Job Number VIA 150A FILTER NEW PANEL 11.26.18 W5563002 Ckt Breaker Type Trip Wire Size Load Served Load Amps Ph B I Ph C Location Frame I Ph A la 20A #12 LED LIGHT FIXTURES 13.5 3b 20A #12 AMS 5c 20A #12 (4) QUAD RECEPT. "' ' r ' u • s - 12.0 7a 20A #12 (4) QUAD RECEPT. 12.0 r c • t c ro 9b 20A #12 (1) QUAD RECEPT. ' , 11c 30A #10 (1) L5-30 RECEPT. -- tt• .1 _ ,r -,— I 3 13a 3P #4 PANEL 2A17 rrrrrrrz-t 15b #4 , " - r L., _... r- ks Ft r 17c #4 , 19a 20A #12 (1) QUAD RECEPT. 3 r c r 7 r .!' ... ; 21b 20A #12 (1) QUAD RECEPT. 3r, - rt -r 23c 20A #12 (1) QUAD RECEPT, 25a 20A SPARE 27b 20A SPARE - . — 29c 20A SPARE - .1:-' o- rt• - - — C r; Or 1 31a 20A SPARE 33b 20A SPARE 35c 20A SPARE r 37a 20A SPARE ,,,,streamlvon,s 39b 20A SPARE r . • :- 41c 20A SPARE • c 2a 20A SPARE 4b 20A #12 (4) QUAD RECEPT. -1, rk r. 12.0 ,- r 6c 20A #12 (3) QUAD RECEPT. , ti ,- o ' r, i' a ,-, P 9.0 8a 20A #12 (3) QUAD RECEPT. 9 10b 20A #12 (1) QUAD RECEPT. - c ! c z 3 12c 20A #12 (1) QUAD RECEPT. . r c r: ',' 7-f. tr,,,*f:.0 3 14a 20A #12 (1) QUAD RECEPT. 3 xr-roc. 16b 20A SPARE 7 7 7 18c 20A SPARE 7" C7 c. 20a 20A SPAREi:•:- 22b 20A SPARE , 24c 20A #12 HEAT PUMP HP2A19 -, n r,i'. r,; . . ‘4.t,t,cocl 13 26a 3P„ #4 PANEL 2A17-1 r . . . 28b #4 ... f-. r.- c TtIc c c=c 30c #4 nr ,,„' 32a 20A SPARE t., r t r , *r 34b 20A SPARE : P r,i, - , . % h 36c 20A SPARE - =,,,,,,,,,-,,,,,,,-,, 38a 3P #8 HEAT PUMP HP2B19 24, ;r t.. r,r;r , .7' c ryc 40b #8 t '..77 24 42c #8 --..• rtr, Z7 ,r,r,,,,,e.r.r, !,s- :'.-',."'i 24 TOTAL 65 45 67 City of Tukwila Department of Community Development March 12, 2019 JUSTIN HORVATH 15135 NE 92ND ST REDMOND, WA 98052 Correction Letter # 1 ELECTRICAL Permit Application Number EL19-0175 BOEING #9-08.2 - 9725 E MARGINAL WAY S Dear JUSTIN HORVATH, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. • CORRECTION 1). SHEET E4B PANEL 2D10-1 RATED 1000 AMP PROTECTED BY 1200 AT BREAKER IN SWITCHGEAR. REVISE. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. ELI9-0175 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 eb4 PERMIT COORD COP? PLAIN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0175 DATE: 03/26/19 PROJECT NAME: THE BOEING COMPANY SITE ADDRESS: 9725 E MARGINAL WAY S #9-08.2 Original Plan Submittal X Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: hcr 111+11 Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/28/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (ie: Zoning Issues (corrections entered in Reviews) DUE DATE: 04/25/19 r Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0175 PROJECT NAME: BOEING #9-08.2 SITE ADDRESS: 9725 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # DATE: 02/25/19 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: ACorrZ ing Division Public Works Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable (i10 approval/review required) Planning Division Permit Coordinator DATE: 02/26/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews Approved with Conditions Denied (ie: Zoning Issues Notation: DUE DATE: 03/26/19 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire LJ Ping fl PW E Staff Initials: 12/18/2013 City of Tukwila REVISION SUBMITTAL RECEIVED CITY OF TUKWILA MAR 26 2019 PERMIT CENTER Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date; 3/25/19 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431.3670 Web site: ty://www.TukwilaWA,gov Plan Check/Permit Number: EL19-0175 O Response to incomplete Letter # Response to Correction Letter # 1 a Revision # after Permit is Issued 0 Revision requested by a City Building Inspector or Plans Examiner 0 Deferred Submittal # Project Name: Boeing #9-08.2 Project Address: 9725 E Marginal Way S Contact Person:JuStin Horvath Summary of Revision: towrra FA-e eefirae ..144240 A Phone Number: 425-766-2184 Sheet Number(s): eL4 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 444/,_ Entered in TRAKiT on O/c-(' fi C Witeadt. t tt F Revised August SEQUOYAH ELECTRIC LLC Hoene Espafiul Contact Page 1 of 3 Search L&I Safety & Health Claims & Insurance /C Washington State Department of Labor & Industries A-Z Index Help My E.,&" Workplace Rights Trades & Licensing SEQUOYAH ELECTRIC LLC Owner or tradesperson Principals Nichols, David E, PARTNER/MEMBER GHASSEMI, MAHMOOD, PARTNER/MEMBER Angeline, Scott R, PARTNER/MEMBER Jeffrey, Peter Casino, PARTNER/MEMBER Trocano, Rick, PARTNER/MEMBER Nagel, Cheryl L, PARTNER/MEMBER Nichols, Christopher R, PARTNER/MEMBER Doing business as SEQUOYAH ELECTRIC LLC WA UBI No. 602 252 591 15135 NE 92ND ST REDMOND, WA 98052 425-814-6000 KING County Business type Limited Liability Company Governing persons DAVID E NICHOLS MAHMOOD GHASSEMI; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SEQUOEL977S9 Effective — expiration 01/29/2003— 01/30/2021 Designated administrator Nichols, Christopher License type Electrical Administrator Bond HARTFORD CAS INS CO Bond account no. 52BSBAB5541 Active. Meets current requirements. License no. NICHOC*835RE $4,000.00 Received by L&I Effective date 01/29/2003 01/29/2003 Expiration date Until Canceled Help us improve F1T—Kfl'IlG1G01 ,PrT TO--Curvr TrlUT 017Q02-C A \IT= A /1G/1/110 \D=X OF RAW \GS INCLUDED IN SET SHEET NO. DRAWING TITLE REV DATE DRAWING NO. ARCHITECTURAL • 9-08-Al Al COVER SHEET — 11.27,18 9-08-A2 A2 SHEET INDEX — 11.27.18 • 9-08-A3 A3 GENERAL DESIGN NOTES — 11.27.18 r 9-08-A4 A4 ICD ROOM CONSTRUCTION DETAILS — 11.27.18 r 9-08-2A01 2A01 EXITING PLAN D 11.27.18 5-08-2AIlR 2AIlR FLOOR PLAN - REMOVAL — 11.27.18 • 9-08-2AIl 2AIl FLOOR PLAN C 11.27.18 • 9-08-2Al2R 2Al2R FLOOR PLAN - REMOVAL — 11.27.18 i 908-2Al2 2Al2 FLOOR PLAN H 11.27.18 • 9-08-2A282R 2A282R REFLECTED CEILING PLAN - REMOVAL — 11.27.18 • 9-08-2A282 2A282 REFLECTED CEILING PLAN C 11.27.18 • 9-4)8-A351 A351 SCHEDULES — 11.27.18 9-08-A378 A378 INTERIOR ELEVATIONS — 11.27.18 9�08-A379 A379 INTERIOR ELEVATIONS — 11,27.18 � 9-08-A502 A502 MISC SECTIONS AND DETAILS — 11,27,18 � 9-08-A503 A503 MISC SECTIONS AND DETAILS — 11.27.18 � 9-08-A504 A504 MISC SECTIONS AND DETAILS -- 11.27.18 � 9-08-A505 A505 MISC SECTIONS AND DETAILS -- 11.27.18 \iX OF DRAW\CS INCLUDED IN SET SHEET NO. DRAWING TITLE REV DATE DRAWING, NO, VECHA\ICAL • 9-08-M4 M4 EQUIPMENT SCHEDULES N 11,27.18 • 9-08-2MIIR 2MIIR SECOND FLOOR HVAC PLAN - REMOVAL C 11,27,18 • 9-08-2M12R 2M12R SECOND FLOOR HVAC PLAN - REMOVAL J 11.27,18 � 9-08-2M11 2M11 SECOND FLOOR HVAC PLAN C 11.27.18 • 9-08-2M12 2M12 SECOND FLOOR HVAC PLAN J 11.27.18 • 9-08-2M62R 2M62R SECOND FLOOR PIPING PLAN - REMOVAL D 11.27.18 • 9-08-2M62 2M62 SECOND FLOOR PIPING PLAN D 11.27.18 • 9-08-2M262R 2M262R FIRE PROTECTION 2ND FLOOR PLAN - REMOVAL A 11.27.18 • 9-08-2M262 2M262 FIRE PROTECTION 2ND FLOOR PLAN A 11.27.18 • 9-08-M527 M527 HVAC SECURITY DETAILS - REFERENCE ONLY A 11,27.18 • 9-08-M529 M529 HVAC DETAILS A 11.27.18 SEPARATE PERMIT AND APPROVAL REQUIRED 1 \DIX OP DRAW \CS INCLUDE) IN SET SHEET NO. DRAWING TITLE REV DATE DRAWING NO, ELECTRICAL • 9-08-E4CR E4CR ONE LINE DIAGRAM MAIN SWITCHGEAR #2 (2ND FLR, I OF 2) B 11.27.18 • 9-08-2E6BR 2E6BR PAGING SYSTEM - SECOND FLOOR - REMOVAL C 11.27,18 • 9-08-2E6CR 2E6CR PAGING SYSTEM - SECOND FLOOR - REMOVAL B 11.27.18 • 9-08-2E9CR 2E9CR SIGNAL REFERENCE GRID - SECOND FLOOR - REMOVAL B 11.27.18 • 9-08-2E12R 2E12R SECOND FLOOR LIGHTING PLAN -REMOVAL K 11,27.J8 • 9-08-2E62R 2E62R 208Y/120V POWER PLAN - REMOVAL W 11.27,18 • 9-08-2E112R 2E112R 480Y/277V POWER PLAN SECOND FLOOR - REMOVAL D 11.27.18 • 9-08-2E362R 2E362R TELEPHONE SECOND FLOOR - REMOVAL C 11.27.18 • 9-08-2E412R 2E412R LAN SYSTEM SECOND FLOOR - REMOVAL C 11.27.18 • 9-08-E311BR E311BR LOW VOLTAGE LIGHTING CONTROL SCHEDULE SECOND FLOOR - REMOVAL B 11.27.18 • 9-08-E4B E4B ONE LINE DIAGRAM MAIN SWITCHGEAR SG-2 A 11.27.18 • 9-08-E4C E4C ONE LINE DIAGRAM MAIN SWITCHGEAR #2 (2ND FLR, I OF 2) B 11.27.18 • 9-08-2E6B 2E6B PAGING SYSTEM - SECOND FLOOR C 11.27.18 • 9-08-2E6C 2E6C PAGING SYSTEM - SECOND FLOOR B 11.27.18 • 9-08-2E9C 2E9C SIGNAL REFERENCE GRID - SECOND FLOOR B 11.27.18 • 9-08-2E11 2E11 SECOND FLOOR LIGHTING PLAN C 11.27.18 � 9-08-2E12 2E12 SECOND FLOOR LIGHTING PLAN K 11.27.18 • 9-08-2E62 2E62 208Y/120V POWER PLAN W 11.27.18 • 9-08-2E112 2E112 480Y/277V POWER PLAN SECOND FLOOR D 11.27,18 • 9-08-2E260 2E260 SMOKE DETECTION SYSTEM - SECOND FLOOR A 11.27,18 • 9-08-2E362 2E362 TELEPHONE - SECOND FLOOR C 11,27,18 • 9-08-2E412 2E412 LAN SYSTEM - SECOND FLOOR C 11.27,18 • 9-08-E311B E3116 LOW VOLTAGE LIGHTING CONTROL SCHEDULE SECOND FLOOR B 11.27,18 • 9-08-E313 E313 LIGHTING SCHEDULE AND DETAILS F 11.27.18 • 9-08-E527 E527 SHIELDING AND TEMPEST ROOM REQUIREMENTS A 11.27,18 • 9-08-E528 E528 SHIELDING AND TEMPEST ROOM REQUIREMENTS A 11,27.18 • 9-08-E529 E529 SHIELDING AND TEMPEST ROOM REQUIREMENTS A 11.27.18 • 9-08-E530 E530 LIGHTING CONTROL WIRING A 11.27.18 • 9-08-E531 E531 ENLARGED PLAN DETAILS - 11.27.18 REVISIONS ONS No changes shall be made to the scope of work without prior approval of the Tukwila Building Division. NOTE: Pevisions will require a new plan submittal aniy may include additional plan review. SEPARATE PERMIT UIRED FOR: Mechanical ❑ Electrical Pltmibing, Gas Piping City of Tukwila BUILDING DIVISION FOL1t COYL6 Permit No. Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fieta Copy and ditlonstis acknowledges: By} Date: lc r(o City of Tukwila BUILDING DIVISION 13 COf PLNOEEC Wf TH NFPA O.. APR 12 2019 15 City of Tukwila JS BUILDING DIVISION REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 9-08.2 TENANT IMPROVEMENT W5563002 SITTS BKL 11.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN L. McVay CHECKED B. Leslie SS L 0 NOT YET ISSUED PREVIOUSLY ISSUED, NOT IN THIS ISSUE IN THIS ISSUE PREL PRELIMINARY ISSUE FOR REVIEW OR INFORMATION ONLY NOT FOR CONSTRUCTION ORIGINAL ISSUE FOR PERMIT, BID, PROCUREMENT OR CONSTRUCTION A FRO DRAWING REVISION -SEE SPECIFIC DRAWING FOR NATURE OF REVISION FOR REFERENCE ONLY RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 SITTS & HILL ENGINEERS, INC. CIVIL ■ STRUCTURAL • SURVEYING 4815 CENTER STREET 1 TACOMA, WA. 98409 PHONE: (253) 474-9449 1 FAX: (253) 474-9449 http:llwww.sitts-hill-englneers.comr Project No.: 18035 Project Mgr.: WJJ Proj. Engineer: DCB Proj. Drafter: LAM DATE 05.04.18 05.04.18 SUBTITLE SHEET INDEX CURRENT REVISION W5563002 SYMBOL DATE 11.27.18 APPROVED BY DEPT. DATE ENGINEER D.Boileau CHECKED W. Jones 05.04.18 05.04.18 APPROVED APPROVED TITLE GENERAL 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 SHEET A2 JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG No. 9-08-A2 LEGEND NOTES \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008—E4CR.dwg 10/16/18 9:27:44 SWITCHGEAR NO. 2 CONTINUED ON < SHEET E4B , SG-2 MAIN SWITCHGEAR NO. 2 480Y/277 V, 4000 A, 3 PH, 4 W (65,000 AMPS RMS SYM. BRACING) FEEDERS FOR PANELS 2C6-2 & 2D6-2 CONTINUED ON SHEET E4K FEEDER SCHEDULE *30 KVA o 208Y/120 V 2C15-3 100 A M. BKR 480/277 V 3 PH, 4 W LIGHTING TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG 4000 A 14 4" 3-500 MCM 250 MCM A 1600 A 6 3" 3-350 MCM #2/0 #1/0 B 1200 A 4 3" 3-350 MCM #2/0 #1/0 � 1000 A 3 3-1/2" 3-500 MCM 250 MCM #2/0 D 800 A 2 3-1/2" 3-500 MCM #4/0 #2/0 © 600 A 2 3" 3-350 MCM #2/0 #1/0 fi 400 A 1 3-1/2" 3-500 MCM 250 MCM #2/0 � SYM REVISION BY APPROVED 2C15-2 400 A M. BKR 480/277 3 PH, 4 FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL CND IG 400 A 1 3-1/2" 3-500 MCM #2/0 © 225 A 1 3" 3 #4/0 500 MCM #2 #2 © 225 A 1 2-1/2" 3 #4/0 #4/0 #2 O 150 A 1 2-1 /2" 3 #1/0 250 MCM #4 #4 0 150 A 1 2" 3 #1/0 #1/0 #4 O 125 A 1 2" 3 #1 #1 #4 0 � 125 A 1 2" 3 #1 #4 DATE SYM REVISION BY 1600 AF 1000 AT I 2D10-1 1000 A M.L.O. 480/277 V 3 PH, 4 W LT ST GF K 2 2nd FLOOR DISTRIBUTION **30 KVA o IJI,JJ r mm 208Y/120 V 2D15-3 100 A M. BKR 480/277 V 3 PH, 4 W LIGHTING **30 KVA o IJI.,JJ Fi9S" 208Y/120 V 2D16 100 A M. BKR 208/120 V 3 PH, 4 W UTILITY FEEDER SCHEDULE 2D15-2 400 A M. BKR 480/277 V 3 PH, 4 W **30 KVA oU,J) 208Y/120 V 2D14 100 A M. BKR 208/120 V 3 PH, 4 W RED (TYP) **30 KVA n^m 208Y/120 V 2D15 100 A M. BKR 208/120 V 3 PH, 4 W RED 2D14-1 100 A M. BKR 208/120 V 3 PH, 4 W BLACK SWITCHGEAR NO. 2 > CONTINUED ON SHEET E4D , o45 KVA 240 V 2E18 150 A M. BKR 240 V 3 PH, 3 W S.E. PROGRAM AREA TYPE RATING CONDUIT CONDUCTORS .PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG 100 A 1 1-1/2” 3 #2 #2/0 #4 #4 P 100 A 1 1-1/2" 3 #2 #2 #4 Q 80 A 1 1-1/2" 3 #4 #6 R APPROVED DATE A RECORD DRAWING JMK MJB 10.01.90 B 9-08.2 TENANT IMPROVEMENT W5563002 CASNE EEK 11.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DATE DRAWN R. HAMMET DATE CHECKED W. KUHLMAN ENGINEER R. HAMMET CHECKED J. KOKOCZKA APPROVED M. BENSTON APPROVED D. SEPTELKA 2D9-2 100 A M. BKR 480/277 V 3 PH, 4 W TRANSFORMERS WITH KVA RATINGS PRECEEDED BY "**" ARE DERATED TO THE VALUE SHOWN. THE ACTUAL MANUFACTURER'S NAMEPLATE RATINGS SHALL BE PER THE FOLLOWING SCHEDULE: DERATED KVA **75 KVA **45 KVA **30 KVA **20 KVA NAMEPLATE KVA 112.5 KVA 75 KVA 45 KVA 30 KVA ALL DERATED TRANSFORMERS ARE TO BE IDENTIFIED BY DERATING NAMEPLATES AS SHOWN ON DETAIL 2, SHEET E502. PROVIDE BREAKER TRIP FUNCTIONS INDICATED ADJACENT TO SWITCHGEAR AIR CIRCUIT BREAKERS. BREAKER SETTINGS TO BE MADE IN ACCORDANCE WITH THE SCHEDULE SHOWN ON SHEET E508. 45 KVA 208Y/120 V 2D10-2 150 A M. BKR 208/120 V 3PH, 4W LIGHTING UTILITY NON -PROGRAM AREAS ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 SUBTITLE TITLE 10.01.90 ELECTRICAL REFRE\CE DRAWINGS CO\S-RUCTIO\ \OTES DISCONNECT AND REMOVE CONDUIT, CONDUCTORS, TRANSFORMERS, PANEL BOARDS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. RELOCATE ANY REMAINING LOADS AFTER OFFICE AREA DEMOLITION TO PANEL 2C16. RE -LABEL BRANCH CIRCUIT DEVICES AND PROVIDE RED LINE DRAWINGS AND SCHEDULE MARKUPS TO ENGINEERING TEAM. SINGLE LINE DIAGRAM MAIN SWITCHGEAR #2 (2ND FLR, 1 OF 2) 9-08.2 TENANT IMPROVEMENT BUILDING 09-08 COLA-F/1-20 GAb 106 EN yVl AIFP,4 0 _ EC APR 1 2 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL 3 DATE 11.27.18 SHEET E4CR JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG No. 09-08-E4CR DEPT. \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E6BR.dwg 0/16/18 9:34:52 SYM A C 1 /2"C, 1#18 .SH.PR. J REVISION RECORD DRAWING MODIFY FOR F-22 BDS LAB PACKAGE 6 SCIF 2 J#910583-12 W5563002 BY APPROVED DATE JMK S.TERRY CASNE MJB W.MARTIN CEC 10.01.90 11-20-91 11.27.18 SYM 4/C#20 3/4"C, (2) #18 TW.SH.PR. 2UNS� 0 0 .S (D) 0 0 REVISION DISCONNECTED AT THIS POINT FOR F22 SECURITY (3 TYP) 1/2"C, 1#18 TN SH.PR. DN DN 3/4"EMT 1_PULLCOR TYP. 4 PL 1 /2"C, (1)F.O. CABLE TO RACK ,A1 I T T 1/2"C, 4/C #20 2 SH. & 2 UNSH, 1/2"C, 1#18 TV,SH,PR, :1111► PR. 0 PARTIAL SECOND FLOOR PLA\ SCALE: 1/8"=1'-0' J ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DATE DRAWN KOKOCZKA DATE CHECKED KUHLMAN SY V 3OLS LECE\D WALL/PARTITION TYPES: , STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. 0 PAGING SPEAKER, FLUSH MOUNTED W/SPEAKER, TRANSFORMER, ENCLOSURE, AND WHITE BAFFEL. MOUNT WITH T-BAR MOUNTING RAILS. MICROPHONE, DESK MOUNT CONDUIT ABOVE FALSE CEILING CONDUIT BELOW RAISED FLOOR ® SOUND MASKING SPEAKER, SEE DETAIL SHT 1E6A, GE ERAL NOTES 1. ALL SPEAKER LINES ARE TWISTED PAIR, SHIELDED CABLE. INSTALLED IN 1/2" FERROUS CONDUIT, MINIMUM, UNLESS OTHERWISE NOTED. 2. THERE ARE NO PAGING SPEAKERS LOCTAED IN MECHANICAL/ELECTRICAL/TELEPHONE ROOMS, STAIRWELLS, CONFERENCE ROOMS OR PRIVATE OFFICES. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A20 FOR IDENTIFICATION OF PROGRAM AREAS. 4. LABEL J-BOXES, "PAGING SYSTEM". 5. MICROPHONE #2 ON SECRETARY'S DESK, AT COLUMN A.5/9. CO\STRUCTIO\ NOTES DISCONNECT AND REMOVE CONDUIT, WIRE, AND ANCILLARY HARDWARE. 2. NO HOME -RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE-ROUTED TO AREA BORDERED E./W. BY GRIDLINES A-C/11.5-12.6 AND N./S. BY GRIDLINES B.8-C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN -USE RACEWAY IS MINIMIZED. KEY PLAN NO SCALE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 NFPA 0 - EC APR 12 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 'KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 SUBTITLE PAGING SYSTEM - SECOND FLOOR CURRENT REVISION W5563002 SYMBOL DATE C 11.27.18 ENGINEER KOKOCZKA CHECKED APPROVED BENSTON APPROVED SEPTELKA 10/1/90 TITLE ELECTRICAL MASTER BDS LAB PACKAGE 6 SCIF 2 BUILDING 9-08 COL. A-F/7-14 SHEET 2E6BR JOB NO. W5563002 COMP NO. DEV, CENTER, WA DWG ND. 9-08-2E6BR DEPT. SY U30LS LEGE\D \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E6CR.dwg 0/16/18 9:40:16 SYM REVISION BY APPROVED DATE SYM REVISION 1 /2"C, 1#18TW.SH.PR. c 0 P n 0 1 1 SECO\D FLOO PLA\ SCALE: 1/8 )=1' -0" BY APPROVED DATE A RECORD DRAWING JMK MJB 10.01.90 B 9-08.2 TENANT IMPROVEMENT W5563002 CASNE CEC 11.27.18 UP DN H v3 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN KOKOCZKA DATE CHECKED KUHLMAN SUBTITLE WALL/PARTITION TYPES: ■u•u • . Mil IN NI IMO STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. PAGING SPEAKER, FLUSH MOUNTED W/SPEAKER, TRANSFORMER, ENCLOSURE, AND WHITE BAFFEL. MOUNT WITH T-BAR MOUNTING RAILS. Q MICROPHONE, DESK MOUNT - CONDUIT ABOVE FALSE CEILING CONDUIT BELOW RAISED FLOOR Kg SOUND MASKING SPEAKER, SEE DETAIL SHT IE6A, GE\HAL \OTES 1. ALL SPEAKER LINES ARE TWISTED PAIR, SHIELDED CABLE. INSTALLED IN 1/2" FERROUS CONDUIT, MINIMUM, UNLESS OTHERWISE NOTED. 2. THERE ARE NO PAGING SPEAKERS LOCTAED IN MECHANICAL/ELECTRICAL/TELEPHONE ROOMS, STAIRWELLS, CONFERENCE ROOMS OR PRIVATE OFFICES. 3. LABEL J-BOXES, "PAGING SYSTEM". CO \STRUCTIO\ \OTES: DISCONNECT AND REMOVE PAGING SPEAKER. DISCONNECT AND REMOVE CONDUIT, WIRE, AND ANCILLARY HARDWARE. DISCONNECT AND REMOVE CONDUIT, WIRE, AND ANCILLARY HARDWARE TO NEAREST J-BOX. KEY PLAN NO SCALE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 PAGING SYSTEM SECOND FLOOR RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL 3 DATE 11.27.18 ENGINEER KOKOCZKA CHECKED APPROVED BENSTON APPROVED SEPTELKA 10/1/90 TITLE 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 ELECTRICAL MASTER COL. A-F/14-20 DEV. CENTER, WA SHEET 2E6CR JOB NO. W5563002 COMP NO. DWG NO. 9-08-2E6CR REVISION A RECORD DRAWING B 9-08.2 TENANT IMPROVEMENT APPROVED REVISION PARTIAL SECO\D FL0N PLA\ SCALE: 1 /8"=1'-0" • .77iairr/7, TYPICAL APPROVED W5563002 CASNE 10.01.90 11.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN J. KOKOCZKA CHECKED W. KUHLMAN ENCINEER J. KOKOCZKA CHECKED J. KOKOCZKA APPROVED M. BENSTON KEY PLAN NO SCALE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 SUBTITLE AD ROVED 10.01.90 ELECTRICAL MASTER SIGNAL REFERENCE GRID SECOND FLOOR 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 COL. A-F/14-20 SYN30LS LEGEND WALL/PARTITION TYPES: STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. PIGTAIL GROUND CABLE, 3'-0" #1/0 BARE COPPER THERMOWELD TYPE CONNECTION, THERMOWELD ONE END WITH 1/8 X 1 SINGLE HOLE LUG. CADWELD NO. B121 CE09 GROUND CABLE ATTACHED TO PEDESTAL, 0-Z/GEDNEY TYPE ABG GROUNDING FITTING. GENERAL \OTES #2 BARE STRANDED COPPER GROUND CABLE ATTACHED TO FLOOR PEDESTAL, SEE DETAIL 2 SHEET E501. #2 GROUND CABLE IN 1/2" C WITH GROUND BUSHINGS. CO\STRUCTIO\ NOTES DISCONNECT AND REMOVE GROUND CABLE. APR 12 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKCWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 JOB NO. DWG NO. SYMBOL 2E9CR W5563002 DATE. 11.27.18 COMP NO. 9-08-2E9CR LEGEND \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E12R.dwg 10/16/18 9:42:58 SYM REVISION [Ei'EfEi'E BY v UL (TYP) APPROVED DATE SYM REVISION (TYP.) i CD cn N •sib' N RC2D15/ — 7a/7aR7,R8 1XD9-1/23c (2 PLS) SECO\D FLOO LICHT\C PLA\ SCALE: 1/8' =1'-0" BY APPROVED DATE A RECORD DRAWING WF JK JK RB 3-3-92 F 9-08 LOWER STAIRWELL LIGHTS 700890-00 VAVREK MOORE 4-6-00 B CONVERT EMERG LIGHT C F-22 AVIONICS EXPANSION D F-22 AVIONICS CONFERENCE RM 75739300 167029 160082 P.T. G SECURE 9-08.2 140641-00 AKC VAVREK 6/29/04 R.H. MEHTA 2-27-96 H F-22 EXPANSION J#557704-00 BAT CJB 06.06.06 P.T. MEHTA J RECORD DRAWING FROGGE BARKER 08.18.06 E CONVERT 9.08 WESTSIDE JSF 774442-00 AISAKA ERICKSON 10-2-97 K 9-08.2 TENANT IMPROVEMENT W5563002 CASNE CEC 11.27.18 �BOE/NG° (TYP) TYP) TYPICAL POWER HOMERUN CALLOUT EXAMPLE: RC2DI5/9b/9bR9,RI0 * RC2DI5 INDICATES LIGHTING CONTROL PANEL * /9b INDICATES A NON —RELAY CONTROLLED CIRCUIT * /9bR9,RI0 INDICATES CONTROL FROM RELAYS R9 & RIO #I2 CONDUCTORS IN I/2"C (UNLESS NOTED OTHERWISE) TYPICAL LOW VOLTAGE HOMERUN CALLOUT EXAMPLE: RC2DI5/R9,RI0 * RC2DI5 INDICATES LIGHTING CONTROL PANEL * /R9,RI0 INDICATES INPUTS TO RELAYS R9 & RIO /2"C, 5/C #I8 (UNLESS NOTED OTHERWISE) REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN R. HAMMETT DATE CHECKED W.KUHLMAN ENGINEER R. HAMMETT CHECKED J.KOKOCZKA APPROVED M.BENSTON APPROVED D.SEPTELKA 10-01-90 SUBTITLE TITLE O • zo ir KIPP/ KEY PLAN NO SCALE M❑ INFRARED MOTION SENSING LIGHT SWITCH U.E.C. MODEL SOM-1000—A INFRARED MOTION SENSING LIGHT SWITCH U.E.C. MODEL SOM-1000—A INSTALLED WITH TWO LINE VOLTAGE SWITCHES 21M EI INFRARED MOTION SENSOR — CEILING MTD. U,E.C. MODEL AICS GE\ ERAL NOTES 1. CONDUIT SHOWN SHALL BE 1/2" EMT UNLESS OTHERWISE NOTED. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 LEFT BUS IN PNL) BLACK BROWN B 0 CENTER BUS IN PNL) RED ORANGE C 0 RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES AS DETAILED. 7. RETURN REDLINE MARKUP DRAWINGS TO ENGINEERING UPON COMPLETION OF JOB. REFERE\CE DAW\GS 7. REFER TO SHEET E313 FOR LIGHTING FIXTURE SCHEDULE. 8. REFER TO SHEET E310 FOR LOW VOLTAGE LIGHTING CONTROL DIAGRAMS. 9. REFER TO SHEET E311 B FOR LOW VOLTAGE LIGHTING CONTROL SCHEDULE AND SWITCH MOUNTING CONFIGURATION. 10 > REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU Al 4 FOR IDENTIFICATION OF PROGRAM AREAS. CONS-RUCTIO\ \OTES DISCONNECT AND REMOVE LIGHT FIXTURE, CONDUIT, CONDUCTOR, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE BACK TO SOURCE. LABEL SOURCE BREAKER AND LIGHTING RELAY AS SPARE. RETAIN LUMINAIRE FOR RE —USE ON THIS PROJECT. DISCONNECT AND REMOVE CONDUIT, CONDUCTORS, AND ALL ANCILLARY HARDWARE TO NEAREST J—BOX NORTH OF COLUMN LINE 14.3. DISCONNECT AND REMOVE LIGHT SWITCH. REMOVE CONDUIT AND CONDUCTORS. ENSURE CONDUIT RUN IS IN HALLWAY, OUTSIDE OF CLOSED ROOMS. 5. REMOVE ALL CONDUIT, CONDUCTORS, BOXES FITTINGS SUPPORTS, AND ANCILLARY HARDWARE WITHIN THE REMOVAL AREA BACK TO J—BOX IN HALLWAY. RE —CIRCUIT LIGHTS TO NEW CIRCUIT AND SWITCH, SEE DRAWING 1E12 FOR NEW CIRCUIT INFORMATION ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 SECOND FLOOR LIGHTING PLAN gOiggiNT BUILDING 9-08.2 ELECTRICAL MASTER COL. A—F/14-20 RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION SYMBOL DATE W5563002 • r\ 11.27.18 SHEET 2E12R JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG NO. 9-08-2E12R FEEDER SCHEDULE LEGE\D \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E62R.dwg 03 0 0 m cO 0 20A,IG,R TYP 9 PLACES 2C14/30,32,34 28 IG 2C16/10 2C 4/22,24 22 24 G 24 2C16-1/14,16,18 2C16-1/18,19 OUTLINE OF FURNITURE (TYP) +42" GFI (TYP) 2C16 r' 017 16/9 11 2D1. 13,15 2D16/ c. 2D16 4,1: 3b 18,E GFI (TYP) 2XSD9 8� 2XSD9-2/5,1 DOORBE BOUNDARY (TYPICAL) !/ FLAT CABLE UNDER CARPET 2C16-1/1,3,13 2C14/26,28 ON CEILING FOR BARCO PROJECTOR (500W) PLAN VU—FOIL PROJECTOR (350W) pIf$\---2 D 15/25, 27, 29 2D14 2D14-1 \ D14-1/1,3,5,",9,10 2D14/20,22,24 2XSD9-2/12,14� 2D15/19,21,23 UN 1D16 1a JE DN SCALE: 1/8" = 1'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE W 9-08.2 TENANT IMPROVEMENT W5563002 CASNE CEC 11.27.18 R F-22 EXPANSION J#557704-00 BAT CJB 06.06.06 S RECORD DRAWING FROGGE BARKER 08.18.06 M SECURE 9-08.2 140641-00 AKC VAVREK 6/29/04 T RELOCATE OUTLET 9-08.2 J#3776223 VAVREK VAVREK 12.11.06 N RECONFIGURE EMERGENCY POWER 53416810 BEIER 2/11/05 U INSTALL OVERHEAD PROJECTOR 4521905 VAVREK VAVREK 05.02.07 P ROOM 21E15/21E16 MOD J#1001694472 SANTOS VAVREK 5/24/05 V INSTALL DOORBELL C187089 M.SANIDAD M.SANIDAD 04.23.18 T2E18 45 kVA 7,29 \ r 16,21,23 26 2D 4-1/26, 28,30 3pp 2D14/3 HB O go 1 /h 2D 14-1 /36,38,40 36 38 TYPE QP RATING 100A CONDUIT CONDUCTORS PER CONDUIT QV' SIZE PHASE NEUTRAL GND. IG Q 150A 1 1 1/2" 3#2 #2/0 #4 #4 2" 3#1/0 — — #4 CO\STUCTIO \ \OTES: DISCONNECT AND REMOVE TRANSFORMER, TRANSFORMER IS LOCATED ABOVE DROP CEILING AT ABOUT B.5, AND NOT AS SHOWN ON DRAWING DISCONNECT AND REMOVE PANELBOARD, PATCH WALL OVER CAVITY REVEALED BY PANELBOARD REMOVAL DISCONNECT AND REMOVE CONDUIT, CONDUCTORS, AND ALL ANCILLARY HARDWARE TO NEAREST J—BOX NORTH OF COLUMN LINE 14.3. NO HOME —RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE—ROUTED TO AREA BORDERED E./W. BY GRIDLINES A—C/11.5-12.6 AND N./S. BY GRIDLINES B.8—C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN —USE RACEWAY IS MINIMIZED. SEE SHEET 2E62 FOR NEW HOMERUN FOR CKTS REMAINING ON WEST SIDE OF WALL 6. DISCONNECT AND REMOVE RECEPTACLES AND ASSOCIATED 600V CONDUCTORS, CONDUIT, AND ANCILLARY HARDWARE BACK TO SOURCE. LABEL SOURCE BREAKER AS SPARE. 7 RELOCATE ANY REMAINING LOADS AFTER OFFICE AREA DEMOLITION TO PANEL 2C16. RE —LABEL BRANCH CIRCUIT DEVICES AND PROVIDE RED LINE DRAWINGS AND SCHEDULE MARKUPS TO ENGINEERING TEAM. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN W.HEDMAN DATE CHECKED W.KUHLMAN SUBTITLE SYMBOL AMP VOLT, POLE WIRE MANUF, RECEPT. ISO, GRD. NEMA 15 120 2 3 HUBBELL IG5262 X 5-15R " ,G':c t3gc 20 120 2 3 HUBBELL IG5362 X 5-20R t omA 30 240 2 4 HUBBELL 9630 NO 331 50 240 3 4 BRYANT 9450 NO 14-50R 33r 30 240 3 30 HUBBELL 9430 NO 14-30R t-0- 20 120 2 3 HUBBELL IG2310A X L5-20R p — AS REQ'D, — — DIR. CONN. — — — SEE GENERAL NOTE 10 ® INDICATES TELEPHONE/POWER POLE WITH POWER ONLY (POWER SERVICE POLE) JUNCTION BOX FOR FURNITURE WHIP CONNECTION. 4" HOLE THRU RAISED FLOOR DIRECTLY ABOVE. NEMA 5—L5R RECEPTACLE (HUBBELL 5262-1) 10 (2) NEMA 5—L5R RECEPTACLE (HUBBELL 5262-1) I-0 NEMA L6-20R RECEPTACLE (HUBBELL 2320) D#12 REPRESENTS (8) #12 WIRES CONSISTING OF THE FOLLOWING: (3) PHASE CONDUCTORS, (3) NEUTRALS (1) ISOLATED GROUND (1) SYSTEM GROUND GE\E�AL \OTES 1. CONDUIT SHOWN SHALL BE 1/2" EMT UNLESS OTHERWISE NOTED. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B 0 (CENTER BUS IN PNL) RED ORANGE C 0 (RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES AS DETAILED. 7. RETURN REDLINE MARKUP DRAWINGS TO ENGINEERING UPON COMPLETION OF JOB. 8. RECEPTACLES AND JUNCTION BOXES WITH THE LETTER 'R' ADJACENT, DENOTE RED POWER SOURCE. 9. CONDUITS HAVING MULTIPLE CIRCUITS HAVE #10 AWG NEUTRAL CONDUCTOR, UNLESS OTHERWISE NOTED. 10. NEUTRAL CONDUCTOR IS NEXT SIZE LARGER FOR THESE DEVICES. (E.G., FOR #12 AWG PHASE CONDUCTORS, USE #10 NEUTRAL) 11. FLOOR PENETRATION: (PROGRAM AREAS ONLY) POWER GROMMET A MINIMUM OF 6" (EDGE TO EDG) FROM THE DATA AND/OR TELEPHONE GROMMET. 12. POLE SEPARATION: (PROGRAM AREAS ONLY) POWER SERVICE POLE A MIN. OF 6" (EDGE TO EDGE) FROM THE DATA AND/OR TELEPHONE SERVICE POLE. 13. ALL DERATED TRANSFORMERS ARE TO BE IDENTIFIED BY DERATING NAMEPLATES AS SHOWN ON DETAIL 2, SHEET E502 14 OUTLET 12" ABOVE SUSPENDED CEILING FOR SECURITY SYSTEM. 115 > OUTLET AT 7'-0" AFF FOR SECURITY SYSTEM USE. CIRC. 2XD9-2/17 ENERGIZES ACCESS MANAGEMENT SYSTEM. 16 >100VA, SINGLE PHASE, 120/16VAC, TRANSFORMER WITH BUSSMAN TYPE "HPM" FUSE HOLDER ON PRIMARY SIDE. 1A, TYPE "FNM" FUSE IN HOLDER. DEVICES 12" ABOVE SUSPENDED CEILING. (FOR SECURITY SYSTEM) 7>CONNECTION TO MECHANICAL SMOKE DAMPERS CONNECTED TO CIRCUIT 2XD9-2/11, CIRCUIT LINES NOT SHOWN. 18 >CONNECTION TO MECHANICAL SMOKE DAMPERS CONNECTED TO CIRCUIT 2XD9-2/13b, CIRCUIT UNES NOT SHOWN. 1 ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 ENGINEER J.MORAN CHECKED J.KOKOCZKA APPROVED J.BENSTON APPROVED D.SEPTELKA TITLE ELECTRICAL MASTER 208Y/120V POWER PLAN 9-08.2 TENANT IMPROVEMENT BUILDING 9-08.2 COL. A—F/8-13 19 CONNECTION TO FIRE PROTECTION SYSTEM PAD-2 (ALARM EXTENSION UNIT) CONNECTED TO CIRCUIT 2XD9-2/5, CIRCUIT LINES NOT SHOWN. SEE D FO 00 PA 70 p��NFPTI9 APR 12 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 25 2019 PERMIT CENTER O 0 KEY PLAN CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL DATE 11.27.18 SHEET 2E62R JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG ND. 9-08.2-2E62R FEEDER SCHEDULE \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E112R.dwg 10/16/18 10:03:09 SYM A B C D REVISION RECORD DRAWING F-22 AVIONICS CONFERENCE ROOM PROVIDE COOLING TO IDF ROOM 9-08.2 TENANT IMPROVEMENT J#160082-00 #770175-00 W5563002 BY JMK P.T. AISAKA CASNE APPROVED MJB J.V. N.M. VAVREK CEC DATE 10/01/90 08.21.86 04.02.97 11.27.18 SYM T2C14 T2C14-1 HI52C'14 3HP 30/15 #10 2C 15-1 /(8,10,12) 2D10-1/(2,4,6) 2C15-2/(1,3,5) 2C15-1/2,4,6 #10 2C15-2/(2,4,6 REVISION (2,4,6) 2C15-3 2C15-I/(27) FLOOR PLA\ SCALE: 1 /8"=1'-0" BY H,F 17 \I HP/ 2D15-1/ (19,21,23) 30/20 APPROVED H21�CIf \2HP/ DATE T2D14 14-1 15 H 2DI4 30/15 #10 2D15-1/(7,9,11) 2D 10-1 /(8,10,12) 2D15-2/(2,4,6) 2D15-2/(1,3,5) T2E18 2D15-1 (2,4,6 2D15-1 (13,15,17) 2D15-1 (14,16,18)1 P0 30/15 �E \2HP/ 2D15-1/(29 #12 �P2E16 4HP% ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE J. KOKOCZKA CHECKED W. KUHLMAN 0 2E110 iLE1 1 12E111 RECEIVED KEY PLAN CITY OF TUKWILA NO SCALE FEB 2 5 2019 PERMIT CENTER SUBTITLE TYPE RATING CONDUIT QTY CONDUC I OHS PER CONDUI I � 400 A 1 SIZE 3-1/2" PHASE 3-500 MCM NEUIHAL 250 GND #2/0 O 225 A 1 MCM 100 A 1 2-1/2" 3 #4/0 #4/0 #2 Q 80 A 1 1-1/2" 3 #2 #2 #4 R 1-1/2" 3 #4 #G IEED FO 00 PLIANCE WITH NFPA770-NEC APR 12 2019 City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 480Y/277V POWER PLAN SECOND FLOOR SYMBOLS LEGEND REFER TO SHT. El FOR GENERAL SYMBOLS LEGEND WALL/PARTITION TYPES: .••a••• IOU .®® STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. GENERAL NOTES 1. ALL CONDUIT 1/2" E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE #12 AWG THWN/THHN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS IS OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS: "A" PHASE (LEFT BUS IN PANEL) "B" PHASE (CENTER BUS IN PANEL) "C" PHASE (RIGHT BUS IN PANEL) NEUTRAL EQUIPMENT GROUND 208/120V 480/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GREEN GRAY GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS ARE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC. WITH CIRCUIT IDENTIFICATION. 6. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. TRANSFORMERS ARE DERATED TO THE VALUE SHOWN. THE ACTUAL MANUFACTURER'S NAMEPLATE RATINGS ARE PER THE FOLLOWING SCHEDULE: DERATED KVA 75 KVA 45 KVA 30 KVA 20 KVA NAMPLATE KVA 112.5 KVA 75 KVA 45 KVA 30 KVA ALL DERATED TRANSFORMERS ARE IDENTIFIED BY DERATING NAMEPLATES AS SHOWN ON DETAIL 2, SHEET E502. 8. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A20 FOR IDENTIFICATION OF PROGRAM AREAS. CONSTRUCTION NOTES: 1. MECHANICAL EQUIPMENT TO BE REMOVED. CONTRACTOR TO DISCONNECT AND REMOVE ASSOCIATED 600V CONDUCTORS, CONDUIT, DISCONNECTS, AND ANCILLARY HARDWARE BACK TO SOURCE. DISCONNECT AND REMOVE TRANSFORMER. TRANSFORMER NOT LOCATED AS SHOWN. TRANSFORMER IS MOUNTED ABOVE FUTURE SCIF DROP CEILING. RELOCATE EXISTING HEAT PUMP TO HALLWAY OUTSIDE OF CLOSED ROOMS, COORDINATE RELOCATION WITH MECHANICAL DRAWING 2M12. REINSTALL WITH THE SAME DISCONNECTS AND CIRCUITS CURRENTLY FEEDING EQUIPMENT. CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL D DATE 11.27.18 ENGINEER J. KOKOCZKA CHECKED J. KOKOCZKA APPROVED M. BENSTON APPROVED D. SEPTELKA TITLE 10.01.90 ELECTRICAL MASTER 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 SHEET 2E112R JOB NO. W5563002 COMP NO. COL. A-F 8-13 DEV. CENTER, WA DWG NO. 9-08-2E112R SY\430LS LECE\D WALL/PARTITION TYPES: 0 0 0 SYM A RECORD DRAWING B INSTALL PHONE C REVISION 9-08.2 TENANT IMPROVEMENT () O TELE. BACKBOARD ED) O L TELE. BACKBOARD L 1 (1) 2 1/2" C.O. (1) 2 1/2' C.O. LLJ L�J -J LOJ a L-XJ UP DN BY WF JK J#1001271981 VAVREK W5563002 CASNE SYM REVISION PARTIAL SECO\D FL00PLA\ APPROVED APPROVED DATE JK RD 3/3/92 VAVREK CEC 06.29.04 11.27.18 35276 rISTEga?'. Z7 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN KOKOCZKA DATE CHECKED KUHLMAN 0 MEM j/ KEY PLAN NO SCALE 1 RED FO,,. PLI NC W1TH FPA 7O -NEC APR 12 2019 City of Tukwila BUILDING DNISION ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 0■■000■ O 0® 0 MIN O M III 1011 STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & CONSTRUCTION DETAILS. PARTITION [0] INDICATES RAISED FLOOR TELEPHONE GROMMET. Q WALL MOUNT TELEPHONE CONDUIT BELOW RAISED FLOOR TQ INDICATES TELEPHONE SERVICE POLE. GE\PAL NOTES 1. LABEL ALL J—BOXES, "TELEPHONE SYSTEM". 2. ALL TELEPHONE CONDUIT SHALL BE MANDRELED, BRUSHED, AND EQUIPED WITH PULL TAPE. 1/2" MIN., UNLESS OTHERWISE NOTED. 3. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A20 FOR IDENTIFICATION OF PROGRAM AREAS. INSTALL 1/2" C.O. (ONLY) TO NOTED LOCATIONS FROM SECURED PROGRAM TELEPHONE ROOM FOR STU 3 AND SECURED FACSIMILE COMMUNICATION LINES. 5. EXACT LOCATION OF GROMMET INSTALLATION WILL BE DETERMINED BY THE LOCATION OF FURNITURE. 6 > REFER TO DETAIL 7, SHEET E502 FOR TYPICAL PHONE GROMMET INSTALLATION. 7. FLOOR PENETRATION: (PROGRAM AREAS ONLY) A. INSTALL POWER GROMMET A MINIMUM OF 6" EDGE TO EDGE FROM THE DATA AND/OR TELEPHONE GROMMET. B. INSTALL DATA GROMMET A MINIMUM OF 3' FROM TELEPHONE GROMMET. 8. POLE SEPARATION: (PROGRAM AREAS ONLY) A. INSTALL POWER POLE A MINIMUM OF 6' EDGE TO EDGE FROM THE DATA AND/OR TELEPHONE POLE. B. INSTALL DATA POLE A MINIMUM OF 3' FROM TELEPHONE POLE. PROVIDE WIREMOLD G-4000 RACEWAY FROM SPACE BELOW FLOOR TO SPACE ABOVE FLOOR; EXTEND 3" INTO EACH SPACE. SURFACE MOUNT, CENTERED ON COLUMN FACE. PROVIDE GROMMET MATERIAL AROUND ENTIRE EDGE OF EACH OPENING. GROUND RACEWAY ABOVE CEILING TO NEAREST BUILDING STEEL WITH #12 WIRE. I 9 > CONS-RUCTIO\ \OTES REMOVE RAISED FLOOR TELEPHONE GROMMET. NO RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE—ROUTED TO AREA BORDERED E./W. BY GRIDLINES A—C/11.5-12.6 AND N./S. BY GRIDLINES B.8—C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN —USE RACEWAY IS MINIMIZED. REMOVE RAISED FLOOR WIREMOLD, AND FLOOR GROMMET. RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNECOM JOB NO. 181-093 SUBTITLE TELEPHONE SECOND FLOOR CURRENT REVISION W5563002 SYMBOL DATE C 11.27.18 ENGINEER KOKOCZKA CHECKED APPROVED BENSTON APPROVED SEPTELKA TITLE 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 SHEET 2E362R JOB NO. W5563002 COMP NO. ELECTRICAL MASTER COL. A—F/14-20 DEV. CENTER, WA DWG NO. 9-08-2E362R J LLI 0-I r�, L_J L_J IV] I I SYM REVISION B REVISION DRAWING B C ROOM 21E15/21E16 MOD 9-08.2 TENANT IMPROVEMENT J#1001694472 W5563002 BY KOKOCZKA SANTOS CASNE LLJ L APPROVED RB VAVREK CEC J 4 ' C.O. DATE 3/3/92 5/24/05 11.27.18 SYM COMMUNICATION CABINETS CABLE TRA MOUNTED IN THESE ROOMS AT 8'-6"A.F.F. C u II 9 > 4" C.O. L�J 1:73 I I L�J LOJ 1 C ri J LJ TYPICAL LLJ rvi LLJ LLI J PARTIAL SECO\D FLOOR PLA\ SCALE: 1 /8"=1'-0" REVISION BY APPROVED UP DN DATE 17 CA3LE TRAY SCHEDULE ITEM MFG ITEM NO. DESCRIPTION O P—W # 2401 4" X 6" CABLE TRAY W/9" RUNG © P—W # 2401 4" X 12" CABLE TRAY W/9" RUNG p—W # 2401 4" X 18" CABLE TRAY W/9" RUNG 4 p-W #-0118-12 18" TO 12" REDUCER SERIES 1 � P—W #-0118-06 18" TO 6" REDUCER SERIES 1 6 P—W #-0112-06 12"TO 6" REDUCER, SERIES 1 0 P—W #9012-12 12" ELBOW WITH 12" RADIUS 8 P—W #9012-18 18" ELBOW WITH 12" RADIUS 9 p—W #2012-12 12" TEE WITH 12" RADIUS 10 P—W #2012-18 18" TEE WITH 12" RADIUS REPRESENTS END OF CABLE TRAY CONSTRUCTIO\ \OTES DISCONNECT AND REMOVE DATA GROMET AND UNDERFLOOR CONDUIT. DATA CABLING TO BE REMOVED BY OTHERS. DISCONNECT AND REMOVE CABLE TRAY, ACCESSORIES, AND ANCILLARY HARDWARE. NO RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE—ROUTED TO AREA BORDERED E./W. BY GRIDLINES A—C/11.5-12.6 AND N./S. BY GRIDLINES B.8-C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN —USE RACEWAY IS MINIMIZED. REMOVE RAISED FLOOR WIREMOLD, AND FLOOR GROMMET, 1 19) C2 21 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN KOKOCZKA DATE CHECKED KUHLMAN SUBTITLE KEY PLAN NO SCALE SY V30L5 LEGEND WALL/PARTITION TYPES: •s••••• milmmommm ®a_® STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & CONSTRUCTION DETAILS. [p] INDICATES RAISED FLOOR DATA GROMMET. OD INDICATES DATA SERVICE POLE. — D 4" IMC DATA CONDUIT P 6" X 6" X 12" PULLBOX WITH CONTINUOUS HINGED COVER AND HASP. PARTITION GENERAL NOTES 1. CABLE TRAY MOUNTED UNDER RAISED FLOOR. 2. CABLE TRAY MOUNTED AT 6" ABOVE SLAB. 3. REFER TO DETAIL ON SHEET 1E410 FOR CABLE TRAY MOUNTING SUPPORT DETAIL. REFER TO DETAIL ON SHEET 1E412 FOR DATA CABLE ENTRANCE DETAIL. REFER TO DETAIL 7, SHEET E502 FOR TYPICAL DATA GROMMET INSTALLATION. 6. EXACT LOCATION OF GROMMET INSTALLATION DETERMINED BY THE LOCATION OF FURNITURE. 7. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THROUGH A14 FOR IDENTIFICATION OF PROGRAM AREAS. 8 > PROVIDE WIREMOLD G-4000 RACEWAY FROM SPACE BELOW FLOOR TO SPACE ABOVE CEILING; EXTEND 3" INTO EACH SPACE. SURFACE MOUNT, CENTERED ON COLUMN FACE. PROVIDE GROMMET MATERIAL AROUND ENTIRE EDGE OF EACH OPENING. GROUND RACEWAY ABOVE CEILING TO NEAREST BUILDING STEEL WITH #12 WIRE. DATA CONDUITS: 9 > 4"C TO CONTAIN 4 — 1 " CARLON OPTIC—GARD CONDUITS. 10. COLOR CODING OF CONDUIT CONFORMS TO THE CHART BELOW: FLOOR BAND 1 BAND 2 NUMBER & COLOR QUADRANT COLOR BAND 3 SECURITY STRIPE #1 BLUE NW — YELLOW NE — GREEN SW — PURPLE SE — ORANGE RED - EVERY 5 FEET (ONLY IN PROGRAM AREA, & 3rd FLR SWITCHROOM.) #2 WHITE NW — YELLOW NE — GREEN SW — PURPLE SE — ORANGE RED — EVERY 5 FEET (ONLY IN PROGRAM AREA, & 3rd FLR SWITCHROOM.) #3 BLACK NW — YELLOW NE — GREEN SW — PURPLE SE — ORANGE RED — EVERY 5 FEET (ONLY IN PROGRAM AREA, AND SWITCHROOM.) #4 ORANGE N — YELLOW S — ORANGE NO BAND #5 GREEN N — YELLOW S — ORANGE NO BAND COLOR BANDS ARE 1" WIDE, PAINTED NOT TAPED NO BANDING IN THE VERTICAL CHASE. BAND 1, AT THE 3rd FLOOR SWITCHROOM END ONLY. BAND 2, AT THE 3rd FLOOR SWITCHROOM END ONLY. ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 LAN SYSTEM - SECOND FLOOR VOICE APR 121019 City of TUkWiie BUILDING DIVISION RECEIVED? CITY OF TUKWILA FEB 25 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL DATE C 11.27.18 ENGINEER KOKOCZKA CHECKED APPROVED BENSTON APPROVED SEPTELKA 10/1/90 TITLE ELECTRICAL MASTER 9-08.2 TENANT IMPROVEMENT BUILDING 09-08 COL. A-F/14-20 DEV. CENTER, WA SHEET 2E412R JOB NO. W5563002 COMP NO. DWG NO. 09-08-2E412R LOW VOLTAGE LIGHTING CONTROL SCHEDULE - NORTH HALF LOW VOLTAGE LIGHTING CONTROL SCHEDULE — SOUTH HALF E 0 E 0 1- O 0 0 V) 0 co N 0 0 .o W N 0 0 O 0 W L.V. LIGHTING CONTROL PANEL LTG. /CKT, PANEL NO. AREA CONTROLLED PLAN SHT. DWG, REF. SWITCHING REMARKS PANEL N0. LOCATION RELAY NO LOCATIONS) DET. N0. SWITCH REF. RC2C6 RC2D6 RI 2C6-3I/1a CORRIDOR (C/3-10) 2E11, 2E12 C4, CIOIi I A2 R2 i i i i Al R3 2C6-3/3b A—C/3-4 2E12 C4, C8 3 A2 R4 � i 1 j j Al R5 2C6-3/5c A—C/4-6 2E12 C4, C8 3 B2 R6 � � i' � � BI R7 2C6-3/7a A—C/6-7 2E12 C4, C8 3 A2 R8 i 1 � � � CI R9 2C6-3/9b A—C/7-9 2E11 C8, CIO 2 A2 RIO � 1 � � � Al RII 2C6-3/Ilc A—C/9—II 2E11 C8, CIO 2 B2 R12 i � � � 1 BI R13 2C6-3/13a SPARE R14 1 i RI5 2C6-3/I5b SPARE R16 R17 2C6-3/17c SPARE RI8 � j RI9 2C6-3/19a SPARE R20 R21 2C6-3/21b SPARE R22 1 i' _ R23 2C6-3/23c SPARE R24 1 i' RI 2D6-3/la D—E/2-3 2E12 D4, DIO 6IF2 R2 1 i i 1 i FI 2D6-3/3b D—F/2-4 2E12 D4, DIO 6 E2 R4R3 iEl R5 2D6-3/5c D—F/4-6� 2E12 D4, DIO 6 D2 R6 � j i j DI 2D6-3/7a D—F/6-7 2E12 D4, DIO 6 C2 R8R7 � CI R9 2D6-3/9b D—F/7-9 2E11 D4, DIO 6 B2 RIO 1 j j � + BI RII 2D6—I/Ilc D—F/9—I10 2E11 D4, DIO 6 A2 R12 j j � 1 � Al 2D6-3/13a C—D/8-9 2E11 C9, D9� I A2 R14 2D6-3/I5b C—D/2-3 2E12 C3, D2 A2 R16 i t �I AI R17 2D6-3/I7c SPARE R18 11 R19 2D6-3/I9a SPARE R20 1 1 R21 2D6-3I/21b SPARE R22 j 1 R23 2D6-3/23c SPARE R24 � 1 SK-2 Al A2 SWITCH LAYOUT Di DETAIL #I 10/16/18 10:23:35 SYM REVISION SK-22 Al A2 BI B2 SWITCH LAYOUT DETAIL #2 BY APPROVED SK-23 Al A2 BI B2 CI C2 DATE SWITCH LAYOUT DETAIL #3 SYM REVISION SK-24 Al A2 BI B2 CI C2 DI D2 SWITCH LAYOUT DETAIL #4 BY APPROVED DATE A RECORD DRAWING JMK MJB 10.01.90 B 9-08.2 TENANT IMPROVEMENT 34355 CASNE EEK 11.27.18 SK-25 L.V. LIGHTING CONTROL PANEL LTG. PANEL ,� AREA �, ;� � PLAN DWG. SWITCHING 3 REMARKS PANEL NO, LOCATION RELAY �0. !'. 0 .. \e RC2C RC2D15 15 /1,1/r/t._ / r. R8 i 1 1 1 CI R9 2C15-3/9b A—C/12-14 2E11 CII, C17 6 B2 RIO � 1 � � � BI RII 2C15-3/Ilc A—C/10-12 2E11 CII, C17 6 A2 R12 1 i � � � Al R13 2C15-3/13a C—D/I2-13 2E11 C13 1 A2 R14 1 1 � '1 � Al RI5 2C15-3/9b SEE REMARKS 2E10,2E11 A.3/13.25 1 A2 A—A.25/13.25-14,75 RI6 1 � � � i Al R17 2C15-3/Ilc SEE REMARKS 2E11 A.3/11.25 1 A2 A—A.25/11.2-12.1 R18 � l' � � � Al RI9 2C15-3/Ilc SEE REMARKS 2E11 A.3/11.75 I A2 A—A:25/10,75—II.5 R20 � i � � � Al R21 2C15-3/21b SPARE R22 'i R23 2C15-3/23c SPARE R24 RI 2D15—I3/1a C,5—D/17.5-19 2E10 C.5, 17,5 1 A2 R2 t � � � 1 Al R3 2D15—I3/3b D—F/16-17 2E10 DI7 1 A2 R4 + � � � � Al R5 2D15—I3/5c D—F/I5I-17 2E10 DII, DIS 4 A2 R6 t + � i � Al R7 2D15—I3/7a D—F/14I —IS 2EI10 DII, 4 B2 R8 i i i i i BI R9 2D15—I3/9b D—F/12-14 2E11 DII, DIS 4 C2 RIO j � � 1 � CI RII 2D15—I3/Ilc D—F/III-12 2E11 DII, DI5 4 D2 R12 t i � j � DI R13 2D15—I3/13a SPARE R14 t RI5 2D15—I3/I5b SPARE R16 t + R17 2D15-3/17c SPARE RIS + R19 2D15-3/19a SPARE NPA��- R20 APR 12 Y019 R21 2D I5-3/21 b SPA ��.�r,�„�, RCF.iVED R22 � IRE + ��?�N° D1`^�N � CITY �F TUKWILA R23 2D I5� 3/23c SPARE FEB 25 2019 R24 PERMIT CENTER AI A2 BI B2 CI C2 DI D2 El E2 SWITCH LAYOUT DETAIL #5 SK-26 (TYP) (TYP) Al A2 BI B2 CI C2 DI D2 El E2 FI F2 SWITCH LAYOUT DETAIL #6 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN R. HAMMET DATE CHECKED W. KUHLMAN ENGINEER R. HAMMET CHECKED J. KOKOCZKA APPROVED M. BENSTON APPROVED D. SEPTELKA SUBTITLE TITLE CONSTRUCTION NOTES 1. DISCONNECT AND REMOVE LIGHT FIXTURE, CONDUIT, CONDUCTOR, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE BACK TO SOURCE. LABEL SOURCE BREAKER AND LIGHTING RELAY AS SPARE. RETAIN LUMINAIRE FOR RE —USE ON THIS PROJECT. ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 LOW VOLTAGE LIGHTING CONTROL SCHEDULE - SECOND FLOOR 9-08.2 TENANT IMPROVEMENT BUILDING 09-08 10.01.90 ELECTRICAL COLA—F/1-20 NOTES I. REFER TO SHEETS 2E10, 2E11 & 2E12 FOR PLANS SHOWING THE CONTROLS LISTED ON THIS DRAWING. 2. REFER TO SHEET E3I0 FOR LOW VOLTAGE LIGHTING CONTROL DIAGRAM. PASS & SEYMOUR CATALOG NUMBERS INCLUDE WALL PLATE AND MOUNTING STRAPS. ALL LOW VOLTAGE MOMENTARY CONTACT SWITCHES ARE PASS & SEYMOUR CATALOG NUMBER 10911. CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL 3 DATE 11.27.18 SHEET E3IIBR JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG No. 09-08—E31 1BR LEGEND \babbage\documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008—E4B.dwg 0 1) Ods rn M 1 8C 8D 1600AF SPACE NORTH SWITCHYARD BRKR #1 I3,8kV FDR TO 9-08 TRANSFORMER T-1 4000 AF 4000 AT r L r 150 L 150 J PAD MOUNT FUSIBLE SWITCH SOUTH OF 9-77 BLDG. 13,800 V 2500/3000 kVA 5.75% IMP 480Y/277V 4000A BUS FROM INCOMING SECT TO SG-2 3 FU 3 PT 120V \./ A3 480 3 CT E 4000:5 T-2 J MULTI— FUNCTION METER PAD MOUNT LIQUID FILLED TRANSFORMER EAST OF BLDG. 480V, 4000A, 3 PHASE, 4 WIRE (65,000 A.I.C.) 4000A BUS FROM SG-2 INCOMING SG-2 MAIN SECT 1 2 3 4 5 6 7 8 9 10 SG-2 INCOMING UNE LUGS BOTTOM SG-1 INCOMING LINE LUGS BOTTOM BLANK SPACE SPACE METERING PANEL 5D10-1 PANEL 3010-3 PANEL 31)10-1 PANEL 4010-1 PANEL 2010-1 PANEL 1010-1 SG-2 MAIN BLANK BLANK SPACE SPACE 9A 1600AF 1600AF SPACE 400AT v REVISION REDRAWN FROM ORIGINAL 9-08.2 TENANT IMPROVEMENT 9B PNL 3D10-1 400A DIST PANEL BY D. OTTEN W5563002 CASNE 9-08.2 TENANT IMPROVEMENT —PERMIT REVISION W5563002 CASNE �9C 1600AF 1000AT v PNL 1D10-1 1000A DIST PANEL APPROVED EEK DAT DATE 08.18.14 11.27.18 03.26.19 SYM 9D 1600AF SPACE REVISION 8A 1600AF SPACE 8B 1600AF T 1200AT PNL 3D10-3 1200A DIST PANEL 0\E-LINE DIAGAv SCALE: SCALE: NONE BY APPROVED DATE 7A 7B 1600AF 1000AT 0 PNL 5D10-1 1000A DIST PANEL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE �7C 1600AF 1000AT v � U Qw M W DM 00 PNL 4D10-1 1000A DIST PANEL DRAWN R. HAMMETT DATE CHECKED W. KUHLMAN SUBTITLE 7D CONTINUED TO SWITCHGEAR #1 SEE SHEET E4a PERMIT REVISION MARCH 26, 2019 SINGLE LINE DIAGRAM MAIN SWITCHGEAR SG-2 TABLE 1: FEEDER SCHEDULE TYPE CONDUIT CONDUCTORS PER CONDUIT Q1Y SIZE PHASE NEUTRAL GND AO 14 4" 3-500 MCM 250 MCM 0 6 3" 3-350 MCM #2/0 #1/0 0 4 3" 3-350 MCM #2/0 #1/0 3 3-1/2" 3-500 MCM 250MCM #2/0 V 2 3-1/2" 3-500MCM #2/0 #2/0 OF 2 3" 3-350 MCM #2/0 #1/0 1 3-1/2" 3-500 MCM 250MCM #2/0 0 1 3-1/2" 3-500 MCM #2/0 0 1 3" 344/0 500MCM #2 OJ 1 2-1/2" 344/0 #4/0 #2 OK 1 2-1/2" 3—#1/0 250MCM #4 0 1 2" 341/0 #1/0 #4 0 1 2" 3—#1 #1 #4 1 2" 3—#1 #4 GE\RAL \OTES REFRE\CE DRAWI\GS CO\ST UCTIO\ \OYES APR I 2 2019 City of Tukwila BUILDING DIVISION CORREC' LTR# RECEIVED CITY OF TUKWILA MAR 2 0 2019. PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE. COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL A 1 DATE 03.26.19 ENGINEER R. HAMMETT CHECKED J. KOKOCZKA APPROVED M. BENSTON APPROVED D. SEPTELKA 10.01.90 TITLE ELECTRICAL MASTER 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 SHEET E4B JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG No. 9-08—E4B LEGEN 1 \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008—E4C.dwg rn 'n 0 0 SWITCHGEAR NO. 2 CONTINUED ON < SHEET E4B SYM A RECORD DRAWING B SG-2 MAIN SWITCHGEAR NO. 2 480Y/277 V, 4000 A, 3 PH, 4 W (65,000 AMPS RMS SYM. BRACING) FEEDERS FOR PANELS 2C6-2 & 2D6-2 CONTINUED ON SHEET E4K REVISION 9-08.2 TENANT IMPROVEMENT 2A15 100A M.C.B 208Y/120V W5563002 BY JMK CASNE *30 KVA o lJ..1J.J - mm 208Y/120 V 2C15-3 100 A M. BKR 480/277 V 3 PH, 4 W LIGHTING 2A15-1 60A M.C.B 208Y/120S APPROVED MJB EEK DATE 10.01.90 11.27.18 2C16 100 A M. BKR 208/120 V 3 PH, 4 W UTILITY 2B14 60A M.C.B 208Y/120S SYM 2C15-2 400 A M. BKR 480/277 V 3 PH. 4 W 112.5 KVA 208Y/120 V 2C15 400A M.C.B 208Y/120V 2B15 60A M.C.B 208Y/120S REVISION 2817 150A M.C.B 208Y/120S 1600 AF 1000 AT 2C18 100A M.C.B. 208Y/120S PF06 PF06 2A17 60A M.C.B 208Y/120V BY I 2D10-1 1000 A M.L.O. 480/277 V 3 PH, 4 W 2A17-1 60A M.C.B 208Y/120V APPROVED DATE LT ST GF K 2 2nd FLOOR DISTRIBUTION **30 KVA o U. JIJ fr mnn 208Y/120 V 2D15-3 100 A M. BKR 480/277 V 3 PH, 4 W LIGHTING **30 KVA ,r(Ym 208Y/120 V P 2D16 100 A M. BKR 208/120 V 3 PH, 4 W UTILITY 2D15-2 400 A M. BKR 480/277 V 3 PH, 4 W **30 KVA o U , JJ r mm 208Y/120 V 2D14 100 A M. BKR 208/120 V 3 PH, 4 W RED (TYP) **30 KVA rmm 208Y/120 V 2D15 100 A M. BKR 208/120 V 3 PH, 4 W RED 2D14-1 100 A M. BKR 208/120 V 3 PH, 4 W BLACK o�IJfi45KVA 240 V SWITCHGEAR NO. 2 > CONTINUED ON SHEET E4D 2E18 150 A M. BKR 240 V 3 PH, 3 W S.E. PROGRAM AREA FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG 4000 A 14 4" 3-500 MCM 250 MCM 1 A 1600 A 6 3" 3-350 MCM #2/0 #1/0 B 1200 A 4 3" 3-350 MCM #2/0 #1/0 � 1000 A 3 3-1/2" 3-500 MCM 250 MCM #2/0 � 800 A 2 3-1/2" 3- 500 MCM #4/0 #2/0 � 600 A 2 3" 3-350 MCM #2/0 #1 /0 GO 400 A 1 3-1/2" 3-500 MCM 250 MCM #2/0 � 21 2D9-2 100 A M. BKR 480/277 V 3 PH, 4 W 3 NOTE PF061 pF� a pF151 POWER FILTER: UNIVERSAL SHIELDING CORP. AC POWER FILTER. SIZE AS NOTED ON DRAWING 09-008-1E60, 2E62 & E531. - USC-50-4X60: 208/120V, 3PH, 4W, 60A - USC-50-4X100: 208/120V, 3PH, 4W, 100A - USC-50-4X150: 208/120V, 3PH, 4W, 150A TRANSFORMERS WITH KVA RATINGS PRECEEDED BY "**" ARE DERATED TO THE VALUE SHOWN. THE ACTUAL MANUFACTURER'S NAMEPLATE RATINGS SHALL BE PER THE FOLLOWING SCHEDULE: DERATED KVA NAMEPLATE KVA **75 KVA **45 KVA **30 KVA **20 KVA 112.5 KVA 75 KVA 45 KVA 30 KVA ALL DERATED TRANSFORMERS ARE TO BE IDENTIFIED BY DERATING NAMEPLATES AS SHOWN ON DETAIL 2, SHEET E502. PROVIDE BREAKER TRIP FUNCTIONS INDICATED ADJACENT TO SWITCHGEAR AIR CIRCUIT BREAKERS. BREAKER SETTINGS TO BE MADE IN ACCORDANCE WITH THE SCHEDULE SHOWN ON SHEET E508. AfY 45 KVA 208Y/120 V 2D10-2 150 A M. BKR 208/120 V 3 PH, 4 W LIGHTING UTILITY NON -PROGRAM AREAS FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT , , ► IG 200 A 1 2" 3 #3/0 1 #3/0 #6 411 0 o1 150 A 1 2" 3 #1/0 #1/0 #4 O 0 GI ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN R. HAMMET DATE CHECKED W. KUHLMAN *Lf1U9Nttk R. HAMMET CHECKED J. KOKOCZKA APPROVED M. BENSTON APPROVED D. SEPTELKA 10.01.90 SUBTITLE TITLE REFERENCE DRAWI\GS CO\STUCTON \OTES 1. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. PROVIDE AND INSTALL 208Y/120V, 30, 4W, NEMA 12, SURFACE MOUNT PANELBOARD AND 600V CONDUCTORS, CONDUIT, AND ANCILLARY HARDWARE BACK TO SOURCE VIA POWER FILTER. PROVIDE AND INSTALL 400A, 208Y/120V, 30, 4W, NEMA 12, SURFACE MOUNT PANELBOARD PROVIDE AND INSTALL 112.5KVA 480V-120/208V TRANSFORMER RECEIVED CITY OF TUKWILA FEB 25 2019 PERMIT CENTER FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG P 100 A 1 1-1/2" 3 #2 #2/0 #4 #4 Q 100 A 1 1-1/2" 3 #2 #2 #4 80 A 1 1-1/2" 3 •4 ;6 3 R 60 A 1 1"- 3#4 1 #4 #10 � O 400 A 2 2" 3 #3/0 1 #3/0 #3 150 A 1 1-1/2" 3 #1/0 1 #1/0 #6 O 0 100 A 1 1" 3 #1 1 #1 #8 ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 ELECTRICAL SINGLE LINE DIAGRAM MAIN SWITCHGEAR #2 (2ND FLR, 1 OF 2) 9-08.2 TENANT IMPROVEMENT BUILDING 09-08 COL.A-F/1-20 DEV. CENTER, WA CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNECOM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL 3 DATE 11.27.18 SHEET E4C JOB NO. W5563002 COMP NO. DWG NO. 09-08-E4C I:\ES\Projects\18\181-093 SH Boe 9-08 Lab Package 6 CLOSED 2\_Drawings\09-008-2E6B.dwg rn N SYM 1 /2"C, 1#18 TW.SH.PR. 2 1/2"c, _A 4 C#20 3/4"C, (2) #18 TW.SH.PR. i� 0 0 /2"C 1 MN H.'R. O 0 0 REVISION BY APPROVED DATE SYM 1 4 1/2"c, 1#1 1/2 c, (1)F.0. CABLE TO RACK#A1 3/4"E (TYP. TTYYP. 4 'I. TW.SH.PR I T T REVISION c 1 /2"C, 4/C #20 (7) (8) (9) DISCONNECTED AT THIS POINT FOR F22 SECURITY (3 TYP) 0 0 S H P� PARTIAL SECOND FLOOR PLAN SCALE: 1/8'=1'-0" BY APPROVED DATE A RECORD DRAWING JMK MJB 10.01.90 B MODIFY FOR F-22 C BDS LAB PACKAGE 6 CLOSED 2 J#910583-12 W5563002 S.TERRY CASNE W.MARTIN CEC 11-20-91 11.27.18 1 J ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN KOKOCZKA DATE CHECKED KUHLMAN 1 z; SUBTITLE SYM3OLS LEGE\D WALL/PARTITION TYPES: ■ sass.■ N MI .IIII Inn STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. Co PAGING SPEAKER, FLUSH MOUNTED W/SPEAKER, TRANSFORMER, ENCLOSURE, AND WHITE BAFFEL. MOUNT WITH T—BAR MOUNTING RAILS. lc/ MICROPHONE, DESK MOUNT CONDUIT ABOVE FALSE CEILING CONDUIT BELOW RAISED FLOOR SOUND MASKING SPEAKER, SEE DETAIL SHT 1E6A, GE HAL \OTES 1. ALL SPEAKER LINES ARE TWISTED PAIR, SHIELDED CABLE. INSTALLED IN 1/2" FERROUS CONDUIT, MINIMUM, UNLESS OTHERWISE NOTED. 2. THERE ARE NO PAGING SPEAKERS LOCTAED IN MECHANICAL/ELECTRICAL/TELEPHONE ROOMS, STAIRWELLS, CONFERENCE ROOMS OR PRIVATE OFFICES. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A20 FOR IDENTIFICATION OF PROGRAM AREAS. 4. LABEL J—BOXES, "PAGING SYSTEM". 5. MICROPHONE #2 ON SECRETARY'S DESK, AT COLUMN A.5/9. KEY PLAN NO SCALE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 PAGING SYSTEM - SECOND FLOOR VI " E(D POW-- GONFPA PLIAN0DCPIE WIECTH - APR 12 2019 City of Tukwila @UILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION SYMBOL c DATE 11.27.18 ENCINEER KOKOCZKA CHECKED APPROVED BENSTON APPROVED SEPTELKA 10/1/90 TITLE ELECTRICAL MASTER BDS LAB PACKAGE 6 CLOSED 2 BUILDING 9-08 COL. A-F/7-14 SHEET 2E6B JOB NO. 1001694472 COMP NO. DEV. CENTER, WA DWG ND. 9-08-2E6B PRS3637. 5 /17 /2005 1.43.25 PM \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E6C.dwg c0 0 co SYM A B REVISION RECORD DRAWING 9-08.2 TENANT IMPROVEMENT W5563002 BY JMK CASNE APPROVED MJB CEC DATE 10.01.90 11.27.18 SYM REVISION 1 /2"C, 1 # 18TW.SH.PR. SECOND SCALE: 1/8 '=1'-0" 0 H UP DN FLOO� APPROVED 1 PLA DATE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED Ai'PROVED BY DATE DRAT'N KOKOCZKA 19 2 CHECKED KUHLMAN ENUINEL KOKOCZKA CHECKED APPROVED BENSTON APPROVED SEPTELKA SUBTITLE RIEM KEY PLAN NO SCALE SYIV30LS LEGEND WALL/PARTITION TYPES: STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. 0 PAGING SPEAKER, FLUSH MOUNTED W/SPEAKER, TRANSFORMER, ENCLOSURE, AND WHITE BAFFEL. MOUNT WITH T-BAR MOUNTING RAILS. V MICROPHONE, DESK MOUNT CONDUIT ABOVE FALSE CEILING CONDUIT BELOW RAISED FLOOR SOUND MASKING SPEAKER, SEE DETAIL SHT IE6A. ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 PAGING SYSTEM SECOND FLOOR GENERAL \OTES 1. ALL SPEAKER LINES ARE TWISTED PAIR, SHIELDED CABLE. INSTALLED IN 1/2" FERROUS CONDUIT, MINIMUM, UNLESS OTHERWISE NOTED. 2. THERE ARE NO PAGING SPEAKERS LOCTAED IN MECHANICAL/ELECTRICAL/TELEPHONE ROOMS, STAIRWELLS, CONFERENCE ROOMS OR PRIVATE OFFICES. 3. LABEL J-BOXES, "PAGING SYSTEM". CO\STRUCTION \OTES: 1. PAGING SYSTEM REMOVED • r`O QIDNFPPL 70 - NEC APR 12 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL 3 DATE 11.27.18 10/1/90 TITLE ELECTRICAL MASTER 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 COL. A-F/14-20 SHEET 2E6C JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG NO. 9-08-2E6 C DEPT. \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E9C.dwg rn M Oo 0 oo (o 0 r. SYM REVISION - BY APPROVED DATE SYM REVISION ED) DOOR F" i�• #1/0 CU WIRE 4 ,TO COLUMN C/15 #1/0 CU WIRE TO COLUMN C/17 PARTIAL SECO\D FLOOR PLA\ SCALE: 1 /8"=1'-0" BY APPROVED DATE A RECORD DRAWING JMK MJB 10.01.90 B 9-08.2 TENANT IMPROVEMENT W5563002 CASNE CEC 11.27.18 Q TYPICAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN J. KOKOCZKA DATE CHECKED W. KUHLMAN ENGINEER J. KOKOCZKA CHECKED J. KOKOCZKA APPROVED M. BENSTON APPROVED D. SEPTELKA 10.01.90 SUBTITLE TITLE SYN BOLS LEGEND WALL/PARTITION TYPES: ■...... mommil ®.® STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. -� PIGTAIL GROUND CABLE, 3'-0" #1/0 BARE COPPER THERMOWELD TYPE CONNECTION, THERMOWELD ONE END WITH 1/8 X 1 SINGLE HOLE LUG. CADWELD NO. B121 CE09 GROUND CABLE ATTACHED TO PEDESTAL, O-Z/GEDNEY TYPE ABG GROUNDING FITTING. GROUND BAR, 1/4" X 2" X 10" COPPER BAR WITH 6 - #6-32 HOLES, 2 - MOUNTING BRACKET AND #2 PIGT AS MANUFACTURED BY CADWELD GENERAL NOTES #2 BARE STRANDED COPPER GROUND CABLE ATTACHED TO FLOOR PEDESTAL, SEE DETAIL 2 SHEET E501. #2 GROUND CABLE IN 1/2" C WITH GROUND BUSHINGS. CO\STRUCTIO\ \OTES PROVIDE AND INSTALL GROUND BAR ABOVE DOOR. SEE DRAWING E528 FOR GROUND BAR DETAILS. PROVIDE AND INSTALL CU GROUND WIRE FROM GROUND BAR TO DOOR FRAME. PROVIDE AND INSTALL CU GROUND WIRE FROM GROUND BAR TO POWER FILTER PLATE AND TO DATA FILTER PLATE. PROVIDE AND INSTALL GROUND STUD ASSEMBLY AND CU GROUND WIRE FROM GROUND STUD ASSEMBLY TO BUILDING STEEL. SEE DRAWING E527, DETAIL 1, FOR GROUND STUD ASSEMBLY INSTALLATION INSTRUCTIONS. PROVIDE AND INSTALL CU GROUND WIRE FROM FLOOR PEDESTAL AND ACCESS SLEEVE TO ROOM GROUND BAR. PROVIDE 18" OF EXTRA SPACE ON ROOM FILTER PLATE PROVIDE AND INSTALL BETWEEN ROOM ACCESS: 4" OUTER SLEEVE, METAL CONDUIT, CUT IN HALF AND SEPARATED WITH A I" GAP. LEAVE 3" STICKING OUT OF THE WALL ON BOTH SIDES, 3" PVC I SLEEVE END SPANNING METAL SLEEVE. NNER SLEEVE. INNER SHALL RUN FROM END TO THE I" GAP LEFT BY THE PROVIDE THREADED CAP FOR EACH END. CAP IS TO BE USED TO COVER EACH END WHEN ACCESS SLEEVE IS NOT IN USE. GROUND BOTH END OF METAL SLEEVE TO FACILITY GROUND. KEY PLAN NO SCALE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 SIGNAL REFERENCE GRID SECOND FLOOR 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 ELECTRICAL MASTER COL. A-F/14-20 PROVIDE AND INSTALL 4"RGS CONDUIT ONLY PROVIDING BETWEEN ROOM ACCESS. V�gqlrD� PA 7OC 0T}•i APR 12 2019 ChY of TAMW �UIEDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER A CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 D.C. CURRENT REVISION W5563002 SHEET JOB NO. DWG NO. SYMBOL 2E9C 86062 3 DATE 11.27.18 COMP NO. 9-08-2E9C \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E11.dwg I/2'C, 5 18 RC2CI5/R19,R20 /2"C,5#IE� RC2C15/RI5, S OFFI 16 SYM REVISION N \ LV (TYP) BY 9b APPROVED RC2C6/9b/9bR9,R10 1 /2"C, 5 #18 RC2C6/R1,R2 RC2C6/11c 11cR11,R12 1/2"C, 9 #18 RC2C6/R9-R12 0) x N I/2"C, 5#I8 RC2C15/IR17,RI DATE SYM � � RC2C6/RX 3 4"C 8#18 VIA LCP RC2C15 RELAYS R9,R10,R15 R 6 It._ MEP gionimour p— r RC2C15/9b/9bR9, R10,R15,R16 0 N CO CN 2XD9-1/9b 0 "C, SPAR 1' r, 2CI5-3/2a am2C15-3/2a STAIR TYP i N r€) RC2D6 13aR13,R14 RRIDOR CONFEREN REVISION 2XD9-1� 3/4"C, 17 RC2D15/R5— cn RC2C15/13aR13,R14 2XD9-1/7a SECOND FLOOR LIGHTI SCALE: 1/8' =1'-0" BY APPROVED 1/2'C, 5 #18 RC2D6/R13,R14 0 RC2D6/11c/11cR11,R12 3/4"C, 25 #18 RC2D6/R 1—R 12 RC2D15/11c/11cR11,R12 OFFIC RC2D15/9b/9bR9,R1 3 P.) —QI PROGRAM BOUNDARY 110 'LD �Tb'P3�2a \G PLA\ DATE 0 N in 0 o A F-22 EXPANSION J#557704-00 B RECORD DRAWING C 9-08.2 TENANT IMPROVEMENT W5563002 BAT FROGGE CASNE CJB BARKER CEC 06.06.06 08.18.06 11.27.18 0 � r MWIIMM 9h OFFI E ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DATE (8) TYP) TYP) DRAWN R. HAMLETT DATE 1.1 C 3� CHECKED W. KUHLMAN ENGINEER R. HAM LETT CHECKED J. KOKOCZKA APPROVED M. BENSTON APPROVED D. SEPTELKA 10-01-90 2$ INFRARED MOTION SENSING LIGHT SWITCH U.E.C. MODEL SOM-1000—A INFRARED MOTION SENSING LIGHT SWITCH U.E.C. MODEL SOM-1000—A INSTALLED WITH TWO LINE VOLTAGE SWITCHES INFRARED MOTION SENSOR — CEILING MTD. U.E.C. MODEL AICS WALL/PARTITION TYPES: STC 45 .■■■■■■ KNAMAMA ommoi 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. CE\EAL NOTES 1. CONDUIT SHOWN SHALL BE 1/2", 2#12, #12GND UNLESS OTHERWISE NOTED. 2. ALL WIRE #12 AWG THWN/THHN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS IS OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS: 208/120V "A" PHASE BLACK (LEFT BUS IN PANEL) "B" PHASE (CENTER BUS IN PANEL) "C" PHASE (RIGHT BUS IN PANEL) NEUTRAL WHITE EQUIPMENT GROUND GREEN 480/277V BROWN RED ORANGE BLUE YELLOW GRAY GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS ARE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC. WITH CIRCUIT IDENTIFICATION. 6. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 7. REFER TO SHEET E313 FOR LIGHTING FIXTURE SCHEDULE. 8. REFER TO SHEET E310 FOR LOW VOLTAGE LIGHTING CONTROL DIAGRAMS. 9. REFER TO SHEET 2E311 FOR LOW VOLTAGE LIGHTING CONTROL SCHEDULE AND SWITCH MOUNTING CONFIGURATION. 10> REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A14 FOR IDENTIFICATION OF PROGRAM AREAS. REFER TO DWG 9-08—E310 "SYSTEM TYPE 1D" FOR LIGHT SWITCHING DETAILS. CO\STUCTIO\ NOTES 1. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. 2. NO HOME —RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE—ROUTED TO AREA BORDERED E./W. BY GRIDLINES A—C/11.5-12.6 AND N./S. BY GRIDLINES B.8—C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN —USE RACEWAY IS MINIMIZED. RE —USE REMOVED LOW VOLTAGE DIMMING SWITCH FROM OFFICE AREA DEMO KEY PLAN NO SCALE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 ©O PLIANCEEWIT NFPA 0 e P !C APR 12 2019 City of Tukwila BUILDING DIVISION 8' 4' 0 RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER 4' 8' 16' SCALE: 1 /8"=1'-0" cCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 SUBTITLE SECOND FLOOR LIGHTING PLAN TITLE ELECTRICAL MASTER 9-08.2 TENANT IMPROVEMENT BUILDING 9-08.2 COL. A—F/7-14 CURRENT REVISION W5563002 SYMBOL DATE 11.27.18 SHEET 2E11 JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG NO. 9-08-2E11 DEPT. LEGE\D INFRARED MOTION SENSING LIGHT SWITCH U.E.C. MODEL SOM-1000—A \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E12.dwg m SYM 10/16/18 10:49:35 A 3/4"C, 4#12, #12G 3/4"C, 4#12, #12G 3/4"C, 4#12, #12G 3/4"C, 4#12, #12G 3/4"C, 4#12, #12G (A) REVISION 4#12, 8#18, #12G —3/9b, VIA LCP RC2C15 YS R9,R10,R15,R16 INV 12 40 3/4"C, 4#12, 3 4"C, 2#18, RC2C 15/R 1 12G 3/4' C, 412, #12G 3/4"C, 4#12, 2# 18, . 1 BY APPROVED 3/4"C 4#12, #12G DATE SYM REVISION TYP) 0 T (TYP.) T Aar I I[k:' WI! jaw A Malik re Iry ed 0 N L) N C2C15 2015-3 2D15-3 RC2D1 2C15-3/4b RC2D15/ —, 7a/7aR7,R8 S s 2D15-3/2a 3b 3bR3.R4 1XD9-1/23c (2 PLS) SECO\D FL0N LIGHTI\G PLA\ SCALE: 1 /8' =1'-0" BY APPROVED DATE RECORD DRAWING WF JK JK RB 3-3-92 F 9-08 LOWER STAIRWELL LIGHTS 700890-00 VAVREK MOORE 4-6-00 0 X N � r moo 3/4"C, 17 #18 RC2D15/R5—R12 :�- 1/2"c, 5 #18 RC2D15/R3,R4 (TYP) 13E.0 was�rlr�, ACCEPTABILITY C� G> t THIS DESIGN AND/OR SPECIFICATION IS APPROVED TYP) C1/ DRAWN R. HAMMETT 0 0 $ DM 2'X4' LED RECESSED TROFFER 2'X4' EMERGENCY LED RECESSED TROFF 2'X2' LED RECESSED TROFFER LINE VOLTAGE DIMMER WALL SWITCH WATTSTOPPER# RH4FBL3PW R 2$M MC INFRARED MOTION SENSING LIGHT SWITCH U.E.C. MODEL SOM-1000—A INSTALLED WITH TWO LINE VOLTAGE SWITCHES INFRARED MOTION SENSOR — CEILING MTD. U.E.C. MODEL AICS TYPICAL EXAMPLE * RC2DI * /9b * /9bR9 #I2 CON POWER HOMERUN CALLOUT RC2DI5/9b/9bR9,RI0 5 INDICATES LIGHTING CONTROL PANEL NDICATES A NON —RELAY CONTROLLED CIRCUIT ,RIO INDICATES CONTROL FROM RELAYS R9 & RIO DUCTORS IN I/2"C (UNLESS NOTED OTHERWISE) TYPICAL EXAMPLE * RC2DI * /R9,R /2"C, LOW VOLTAGE HOMERUN CALLOUT RC2D15/R9,RI0 5 INDICATES LIGHTING CONTROL PANEL 10 INDICATES INPUTS TO RELAYS R9 & RIO 5/C #I8 (UNLESS NOTED OTHERWISE) j CO\S-RUCTIO\ \OTES 1. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. 2. NO HOME —RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE—ROUTED TO AREA BORDERED E./W. BY GRIDLINES A—C/11.5-12.6 AND N./S. BY GRIDLINES B.8—C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN —USE RACEWAY IS MINIMIZED. � RE USE LUMINAIRES REMOVED DURING DEMO PROVIDE AND INSTALL 2x2 TROFFER STYLE LUMINAIRE PROVIDE AND INSTALL LINE VOLTAGE SWITCHES WITH BUILT IN 0-10V DIMMING PROVIDE AND INSTALL EMERGENCY FIXTURE WITH BATTERY OPERATED DRIVER RE —USE REMOVED LOW VOLTAGE DIMMING SWITCH FROM OFFICE AREA DEMO PROVIDE ENGINEERING TEAM WITH RELAYING INFORMATION FOR LUMINAIRE FOR RECORD DRAWING UPDATE DATE CHECKED W.KUHLMAN ENGINEER R. HAMMETT SUBTITLE 0 0 zo KEY PLAN NO SCALE 10 GE\ EAL NOTES 1. CONDUIT SHOWN SHALL BE 1/2", 2#12, #12GND UNLESS OTHERWISE NOTED. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: A 0 LEFT BUS IN PNL) B 0 (CENTER BUS IN PNL) C 0 (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND 208Y/120V BLACK RED BLUE 480Y/277V BROWN ORANGE YELLOW WHITE GRAY GREEN GREEN GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES AS DETAILED. 7. RETURN REDLINE MARKUP DRAWINGS TO ENGINEERING UPON COMPLETION OF JOB. 8. REFER TO SHEET E310 FOR LOW VOLTAGE LIGHTING CONTROL DIAGRAMS. 9. REFER TO SHEET E311B FOR LOW VOLTAGE LIGHTING CONTROL SCHEDULE AND SWITCH MOUNTING CONFIGURATION. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A14 FOR IDENTIFICATION OF PROGRAM AREAS. EMERGENCY FIXTURES IN CLOSED ROOMS ARE EQUIPPED WITH BODINE EMERGENCY, BATTERY POWERED, LED DRIVER WITH SELF TEST BUTTON, SEE LIGHTING FIXTURE SCHEDULE FOR PART INFO. BATTERY DRIVER IS GOOD FOR MIN 90MIN AT 10W DEFERENCE NAWI\GS 09-008—E313 LIGHTING SCHEDULE AND DETAILS 09-008—E530 LIGHTING CONTROL WIRING ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 SECOND FLOOR LIGHTING PLAN 430NFPA' P JANCF�PMTi-I O - EC APR 12 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILIA FEB 2 5 2019 PERMIT CENTER 8' 4' 0 4' 8' 16' SCALE: 1 /8"=1'-0" CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE COM JOB NO. 181-093 CURRENT REVISION SYMBOL DATE 11.27.18 SHEET B CONVERT EMERG LIGHT 75739300 P.T. G SECURE 9-08.2 140641-00 AKC VAVREK 6/29/04 C F-22 AVIONICS EXPANSION 167029 R.H. MEHTA 2-27-96 H F-22 EXPANSION J#557704-00 BAT CJB 06.06.06 D F-22 AVIONICS CONFERENCE RM 160082 P.T. MEHTA J RECORD DRAWING FROGGE BARKER 08.18.06 CONVERT 9.08 WESTSIDE JSF 774442-00 AISAKA ERICKSON 10-2-97 K 9-08.2 TENANT IMPROVEMENT W5563002 CASNE CEC 11.27.18 ArdiglEZAW e ti ,. 35'276 4P4bISTE� G1 ONAL ° 21 APPROVED BY DEPT. DATE CHECKED J.KOKOCZKA APPROVED M.BENSTON APPROVED D.SEPTELKA TITLE 9-08.2 TENANT IMPROVEMENT BUILDING 9-08.2 10-01-90 ELECTRICAL MASTER COL. A—F/14-20 2E12 JOB NO. 86062 COMP N0. DEV. CENTER, WA DWG NO. 9-08-2E12 TYPE CKTs L5-30 ' 8 L6-30 4,6 L5-30 9 3/4"C, 6#10,#10GND 3/4" C 2#12, #12GND 1 "C, 3#6, #10 GND/13,15,17 TYPE L5-30 L6-30 L5-30 CKTs 10 5,7 12 1 "C, 6#10, 2#12 #10GND 3/4"C, 4#12 #12GND 3/4"C, 2#12, 12GND 3/4"C, 2#12, 2#10, #10GND _•30 3 >60A NF GND/14,16,18 3/4"C, 4#12, #12GND 2A17 1-1[52A19 HP 7 30A 3/4"C, 4#12, #12GND 10 1 "C, 2#10, 2#12 pomp 2C16 2C15/1,3,5 2C15 7,9,11 - 1-1 2"C, 4# 1 /0, #6 1-1 /2"C, 4#1, #8 GNIt GND 25,27,29,31,33,35 HP2B1§ HP-6 4 1 "C, 2#10, 4#12 #12GND H02BI$ 3 / '� 4 3 4"C, 3 8, #10 GND/7,9,11 1-1/2"C, 8#4, # 0 GND 13,15,17,26,28,30 2C1 /14, 1"C #10 GN 2E62 E531 3/4"C, 3#12, #12 GND/7,9,11 3/4"C, 6#12,#12 GND 3/4"C, 2#12, 3#8, #8 GND/38,40,42,24 _ - 3/4"C, 4#12, 10 6 #12 GND 8 11. 3/4"C, 2#12, #12 GND/24 3/4"C, 2# 10, #10 GND REVISION W 9-08.2 TENANT IMPROVEMENT SECURE 9-08.2 RECONFIGURE EMERGENCY POWER ROOM 21E15/21E16 MOD W5563002 140641-00 53416810 J#1001694472 ...5 3/4"C, 6# 1 CASNE BEIER SANTOS 6 5 4.. #12 GND- APPROVED VAVREK VAVREK 3/4"C, 6#12, #12 GND H152Bi30A HP-6 NF 3/4"C, NM #12 GND 14 11.27.18 6/29/04 2/11/05 5/24/05 R F-22 EXPANSION S RECORD DRAWING T RELOCATE OUTLET 9-08.2 U V +42" CFI (nP) 2C 15/8,10,12 1-1/2"c, 4# 1 /0, #6 GND 3/4"C, 4#12, #12 GND REVISION INSTALL OVERHEAD PROJECTOR INSTALL DOORBELL PLA SCALE: 1/8" = 1'-0" J#557704-00 J#3776223 4521905 C187089 FROGGE VAVREK VAVREK M.SANIDAD 3b v , $ K--2D15/25,27,29 2D14 APPROVED BARKER VAVREK VAVREK M.SANIDAD _ 2D4/2, 2D15/15,17 2D14/6,8,10 ,12 2 r---2 0 Q 1El • 1 f),n 25,2 r,29 MENEM me.ft, • 2015/19,21,23 06.06.06 08.18.06 12.11.06 05.02.07 04.23.18 120A 12 T2E18 45 kVA CO\STUCTO\ OYES: • PROVIDE AND INSTALL CONDUIT, CONDUCTORS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. NO HOME -RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE-ROUTED TO AREA BORDERED E./W. BY GRIDLINES A-C/11.5-12.6 AND N./S. BY GRIDLINES B.8-C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN -USE RACEWAY IS MINIMIZED. PROVIDE AND INSTALL 1-POLE, NEMA 12 DISCONNECT. PROVIDE AND INSTALL ROOM RECEPTACLES. SEE LEGEND FOR DEVICE TYPE. RE-ROUTE HOME RUN OUTSIDE OF SECURE ROOMS TO PANEL 16� 2D 14-1 /36,38,40 36 38 PROVIDE AND INSTALL 208Y/120V, 30, 4W, NEMA 12, SURFACE MOUNT PANELBOARD AND 600V CONDUCTORS, CONDUIT, A ILLARY HARDWARE BACK IU R FILTER. SEE SCH FOR PANEL SI PROVIDE AND INSTALL 400A, 208Y/120V, 30, 4W, NEMA 12, SURFACE MOUNT PANELBOARD PROVIDE AND INSTALL 112.5KVA 480V-120/208V TRANSFORMER PROVIDE AND INSTALL 480V, 30A AND 60A, NEMA 12 DISCONNECT. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DRAWN W.HEDMAN CHECKED W.KU HLMAN ENGINEER J.MORAN CHECKED J.KOKOCZKA APPROVED J.BENSTON APPROVED D.SEPTELKA LECE\D SYMBOL AMP VOLT. POLE WIRE MANUF. RECEPT. ISO. GRD, NEMA 1G 15 120 2 3 HUBBELL IG5262 X 5-15R 3:c 20 120 2 3 HUBBELL IG5362 X 5-20R J 30" 30 240 2 4 HUBBELL 9630 NO eV 50 240 3 4 BRYANT 9450 NO 14-50R 3B" 30 240 3 30 HUBBELL 9430 NO 14-30R t-O 20 120 2 3 HUBBELL IG2310A X L5-20R p - AS REQ'D. - - DIR. CONN. - - - SEE GENERAL NOTE 10 -- (13 INDICATES ESERVICE POLE) POLE WITH POWER JUNCTION BOX FOR FURNITURE WHIP CONNECTION. 4" HOLE THRU RAISED FLOOR DIRECTLY ABOVE. 4-PLEX FLOORSTACK NEMA 5-L5R RECEPTACLE (HUBBELL 5262-1) 4 (2) NEMA 5-L5R RECEPTACLE (HUBBELL 5262-1) NEMA L6-20R RECEPTACLE (HUBBELL 2320) GE\EAL \OYES 1. CONDUIT SHOWN SHALL BE 1/2" EMT UNLESS OTHERWISE NOTED. 2. CONDUCTORS SHOWN: #12AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS IN ACCORDANCE WITH THE LATEST NEC (USING TAPE), COLOR CODE AS FOLLOWS: A0 (LEFT BUS IN PNL) B0 (CENTER BUS IN PNL) C0 (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND 208Y/120V BLACK RED BLUE WHITE GREEN GRN/YEL* 480Y/277V BROWN ORANGE YELLOW GRAY GREEN GRN/YEL* *GREEN WITH YELLOW TRACER DYNO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 6. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES AS DETAILED. 7. RETURN REDLINE MARKUP DRAWINGS TO ENGINEERING UPON COMPLETION OF JOB. 8. 8. RECEPTACLES AND JUNCTION BOXES WITH THE LETTER 'R' ADJACENT, DENOTE RED POWER SOURCE. SUBTITLE TITLE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 208Y/120V POWER PLAN 9-08.2 TENANT IMPROVEMENT BUILDING 9-08.2 ELECTRICAL MASTER COL. A-F/8-13 4-PLEX UNDER FLOOR RECEPT. DUPLEX UNDER FLOOR RECEPT. 20A, 125V, 1 PHASE 4-PLEX RECEPTACLE NEMA 5-20R, WALL MOUNT 1 20A, 125V, 1 PHASE DUPLEX RECEPTACLE, NEMA 5-20R, WALL MOUNT 30 30A, 125V, 1 POLE SINGLE RECEPTACLE, NEMA L5-30R 4. 30A, 250V, 2 POLE SINGLE RECEPTACLE, 30 NEMA L6-30R ao 30A, 208V, 3 POLE SINGLE RECEPTACLE, 30 NEMA L21-30R THREE PHASE, 60A POWER FILTER, UNIVERSAL SHIELDING CORP. USC-50-60B4 POWER FILTER PLATE 208Y/120V, 30, 4W, PANELBOARD TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL EQUIPMENT SIZE. SEE SCHEDULE ON 09-008-M4 FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY. SIZE PHASE NEUTRAL GND. IG 0 100A 1 1 1/2" 3#2 #2/0 #4 #4 0 150A 1 2" 3#1/0 - - #4 9. CONDUITS HAVING MULTIPLE CIRCUITS HAVE #10 AWG NEUTRAL CONDUCTOR, UNLESS OTHERWISE NOTED. 10. NEUTRAL CONDUCTOR IS NEXT SIZE LARGER FOR THESE DEVICES. (E.G., FOR #12 AWG PHASE CONDUCTORS, USE #10 NEUTRAL.) FLOOR PENETRATION: (PROGRAM AREAS ONLY) POWER GROMMET A MINIMUM OF 6" (EDGE TO EDGE) FROM THE DATA AND/OR TELEPHONE GROMMET. 12. POLE SEPARATION: (PROGRAM AREAS ONLY) POWER SERVICE POLE A MIN. OF 6" (EDGE TO EDGE) FROM THE DATA AND/OR TELEPHONE SERVICE POLE. 13. ALL DERATED TRANSFORMERS ARE TO BE IDENTIFIED BY DERATING NAMEPLATES AS SHOWN ON DETAIL 2, SHEET E502 OUTLET 12" ABOVE SUSPENDED CEILING FOR SECURITY SYSTEM. OUTLET AT 7'-0" AFF FOR SECURITY SYSTEM USE. CIRC. 2XD9-2/17 ENERGIZES ACCESS MANAGEMENT SYSTEM. 16 > 100VA, SINGLE PHASE, 120/16VAC, TRANSFORMER WITH BUSSMAN TYPE "HPM" FUSE HOLDER ON PRIMARY SIDE. 1A, TYPE "FNM" FUSE IN HOLDER. DEVICES 12" ABOVE SUSPENDED CEILING. (FOR SECURITY SYSTEM) CONNECTION TO MECHANICAL SMOKE DAMPERS CONNECTED TO CIRCUIT 2XD9-2/11, CIRCUIT LINES NOT SHOWN. 118 > CONNECTION TO MECHANICAL SMOKE DAMPERS CONNECTED TO CIRCUIT 12XD9-2/13b, CIRCUIT LINES NOT SHOWN. 19 > CONNECTION TO FIRE PROTECTION SYSTEM PAD-2 (ALARM EXTENSION UNIT) CONNECTED TO CIRCUIT 2XD9-2/5, CIRCUIT LINES NOT SHOWN. SEE DRAWING 2E261. CX)PLI'y NFPA 0 APR 12 2019 City of sTitI lts f 3UIUDt IDik/itii9l�l , RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER O 0 KEY PLAN DEV. CENTER, WA CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWWCASNE.COM JOB NO. 181-093 CURRENT REVISION JOB NO. DWG NO. W5563002 SYMBOL W5563002 DATE 11.27.18 COMP NO. 9-08.2-2E62 FEEDER SCHEDULE \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E112.dwg CAD REVISION BY APPROVED DATE SYM 2D115-1 2C1 -1 2D9-1/(2,4 6) 2C15-1 2C16 REVISION FLOO PLA\ SCALE: 1/8"=1 -0" BY E) 1111 D9-1/(8, 1 2D15-3 -2C15-2/ 2C 15-2/(1 2D15-1/ (19,21,23) 30/20 APPROVED DATE RECORD DRAWING JMK MJB 10/01/90 F-22 AVIONICS CONFERENCE ROOM J#160082-00 P.T. J.V. N.M. 08.21.86 PROVIDE COOLING TO IDF ROOM #770175-00 AISAKA VAVREK 04.02.97 9-08.2 TENANT IMPROVEMENT W5563002 CASNE CEC 11.27.18 T2D 14 D14-1 T"i15 30/15 #10 2D15-1/(7,9,11) 2D 10-1 /(8,10,12) 2D15-2/(2,4,6) 2D15-2/(1,3,5) T2E18 2D15-1/I (2,4,6 2D15-1 (13,15,17) 2D15-1 (14,16,18) 12FI4 2D15-1/(29 4 2HP% ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN J. KOKOCZKA DATE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND � 400 A 1 3-1/2" 3-500 MCM 250 MCM #2/0 O 225 A 1 2-1/2" 3 #4/0 #4/0 #2 Q 100 A 1 1-1/2" 3 #2 #2 #4 � 175 A 1 2" 3 #2/0 #6 SYMBOLS LEGEND REFER TO SHT. El FOR GENERAL SYMBOLS LEGEND WALL/PARTITION TYPES: STC 45 MIN III NOMIll STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. TYPICAL HEAT PUMP NUMBERING SYSTEM: --EQUIPMENT NUMBER FOR MAINTENANCE & LABEL EQUIPMENT SIZE. SEE SCHEDULE ON 09-008-M4 CONSTRUCTION NOTES: 1. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. 2. oft 6 NO HOME -RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE-ROUTED TO AREA BORDERED E./W. BY GRIDLINES A-C/11.5-12.6 AND N./S. BY GRIDLINES B.8-C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN -USE RACEWAY IS MINIMIZED. PROVIDE AND INSTALL 112.5KVA 480V-120/208V TRANSFORMER RELOCATE EXISTING HEAT PUMP TO HALLWAY OUTSIDE OF CLOSED ROOMS. REINSTALL WITH THE SAME DISCONNECTS AND CIRCUITS CURRENTLY FEEDING EQUIPMENT. SEE MECHANICAL DRAWINGS FOR FINAL LOCATION PROVIDE AND INSTALL 3-POLE, 175A CB IN PANEL. MATCH MANUFACTURER, STYLE, AND AIC RATING CHECKED W. KUHLMAN r CINEER J. KOKOCZKA CHECKED J. KOKOCZKA APPROVED M. BENSTON APPROVED D. SEPTELKA 2E110 0 sos SUBTITLE KEY PLAN NO SCALE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 480Y/277V POWER PLAN SECOND FLOOR GENERAL NOTES ALL CONDUIT 1/2" E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE #12 AWG THWN/THHN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS IS OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS: "A" PHASE (LEFT BUS IN PANEL) "B" PHASE (CENTER BUS IN PANEL) "C" PHASE (RIGHT BUS IN PANEL) NEUTRAL EQUIPMENT GROUND 208/120V 480/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GREEN GRAY GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS ARE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC. WITH CIRCUIT IDENTIFICATION. 6. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 7. TRANSFORMERS ARE DERATED TO THE VALUE . SHOWN. THE ACTUAL MANUFACTURER'S NAMEPLATE RATINGS ARE PER THE FOLLOWING SCHEDULE: DERATED KVA NAMPLATE KVA 75 KVA 112.5 KVA 45 KVA 30 KVA 20 KVA 75 KVA 45 KVA 30 KVA ALL DERATED TRANSFORMERS ARE IDENTIFIED BY DERATING NAMEPLATES AS SHOWN ON DETAIL 2, SHEET E502. 8. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A20 FOR IDENTIFICATION OF PROGRAM AREAS. RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL DATE 11.27.18 10.01.90 TITLE ELECTRICAL MASTER 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 COL. A-F/8-13 SHEET 2E112 JOB NO. 53416810 COMP NO. DEV. CENTER, WA DWG NO. 9-08-2E112 \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E260.dwg 10/16/18 11:05:24 SYM REVISION (2) BY 7A+C+D--e 6A+C+D APPROVED DATE SYM 29A +3C+2 +3T TO 3RD FLOOR RISER 36A+4C+2 +3T TO FACP REVISION BY APPROVED 3 SECO\D FLOOR PLAN SCALE: 1 /16' =1'-0" DATE A 9-08.2 TENANT IMPROVEMENT W5563002 CASNE CEC 11.27.18 II i!i o r'li ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN ACUNA DATE CHECKED PETE PIZA ENGINEER CHECKED SUBTITLE 3A+C+D uoLF ooN X'1,1-)ftr.7, APR 12 2019 City of Tukwila BUILDING DIVISION CU SYv 30LS LEGEND WALL/PARTITION TYPES: STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS, 0 IONIZATION DETECTOR HEAT DETECTOR DUCT MOUNTED SMOKE DETECTOR OD MANUAL PULL STATION ® MAGNETIC DOOR HOLDER OS&Y VALVE SUPERVISORY CIRCUIT WATER FLOW DETECTION SWITCH POST INDICATING VALVE CIRCUIT FIRE ALARM HORN GE\ERAL OTES WON DOOR CONTROLLER 2. REFER TO SHT. E300 FOR ELEVATOR FIRE PROTECTION SYSTEM. 3. REFER TO SHT 1E261 FOR FIRE ALARM SYSTEM RISER DIAGRAM & WIRING SCHEDULE. 4. ALL WIRING INSTALLED IN MINIMUM 1/2" E.M.T. UNLESS OTHERWISE NOTED. 5. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A20 FOR IDENTIFICATION OF PROGRAM AREAS. 6 > SEE DRAWING 9-08—E525 FOR DETAILS ON THE PYROTRONICS `PAD-2' ADDITION. CO\S-RUCTIO\ NOTES: PROVIDE AND INSTALL CONDUIT, CONDUCTORS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. ALL FIRE CONTROL CONDUIT AND WIRE TO BE ROUTED THROUGH ROOM FILTER PLATE PROVIDE AND INSTALL ALARM HORN/STROBE; WITH LOW DECIBEL AUDIBLE ALARM, 96"AFF NO HOME —RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE—ROUTED TO AREA BORDERED E./W. BY GRIDLINES A—C/11.5-12.6 AND N./S. BY GRIDLINES B.8—C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN —USE RACEWAY IS MINIMIZED. RECEIVED CITY OF TUKWILA FEB 252019 PERMIT CENTER ISSUED FOR CONSTRUCTION NOVEMBER 27.2018 SMOKE DETECTION SYSTEM SECOND FLOOR 00 KEY PLAN NO SCALE CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL A DATE 11.27.18 APPROVED PETE PIZA APPROVED 7-9-89 TITLE ELECTRICAL MASTER 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 COL. A—F/1-20 SHEET 2E260 JOB NO. W5563002 COMP NO. DWG NO. D.C. 9-08-2E260 \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008-2E362.dwg m SYM co 0 HVAC COMM FILTER (3) DUAL CIRCUIT ANALOG PHONE FILTERS (TYP) (TYP) (TYP) 14 (TYP) DATA FILTER PLATE HVAC COMM FILTER (1) DUAL CIRCUIT ANALOG PHONE FILTERS REVISION DATA FI LT 3/4" C_0 HVAC COMM FILTER (4) DUAL CIRCUIT ANALOG PHONE FILTERS 3/4" C.O. 3/4" C.O. 3/4" C.O. - 3/4" C.O. DATA FILTER PLATE R PLATE DATA FILTER PLATE DATA FILTER PLATE (1) DUAL CIRCUIT 4 ANALOG 'HONE FILTERS HVAC CO M FILTER BY APPROVED DATE SYM REVISION I'I ,III III:;,- �Iii ;.!!!J HVAC COMM FILTER V!y 'I ) DUAL CIRCUIT �K! I1I !'IiALOG PHONE FILTE ,I III_ I HVAC COMM FILTER (2) DUAL CIRC ANALOG PHON LE. CKBOAR HVAC COMM FILTER HVAC COMM FILTER (18) DUAL CIRCUIT q ANALOG PHONE FILTERS PARTIAL SECO\ SCALE: 1 /8"=1 ' -0" BY LE. ACKBOARD D FLOC PLAN APPROVED DATE A RECORD DRAWING WF JK JK RD 3/3/92 B INSTALL PHONE J#1001271981 VAVREK VAVREK 06.29.04 C 9-08.2 TENANT IMPROVEMENT W5563002 CASNE CEC 11.27.18 (1) 2 1/2" C.O. 1111111111111 nominumi 111111iividl ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PPROVED BY DATE 9-08-E527 SHIELDING 9-08-E528 SHIELDING 9-08-E529 SHIELDING 9-08-E531 DUAL. 20 RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER W KOKOCZKA AT CHECKED KUHLMAN ENGINEER KOKOCZKA CHECKED APPROVED BENSTON APPROVED SEPTELKA SUBTITLE TITLE & TEMPEST ROOM REQUIREMENTS & TEMPEST ROOM REQUIREMENTS & TEMPEST ROOM REQUIREMENTS ANALOG FILTER SCHEDULE CD' 0 2 °NPL gj�1EC WIH 1NFPA 0 - LC APR 12 2019 City of Tukwila BUILDING DIVISION KEY PLAN NO SCALE SYVOLS LEGEND WALL/PARTITION TYPES: STC 45 STC 45 AND PROGRAM STC 50 AND PROGRAM SEE SHEET A37 FOR DETAILS OF WALL & CONSTRUCTION DETAILS. 0 INDICATES RAISED FLOOR TELEPHONE G Q WALL MOUNT TELEPHONE CONDUIT BELOW RAISED FLOOR Q*INDICATES TELEPHONE SERVICE POLE - VE DOR TI 'RIVIIE PERIMETER PERIMETER PARTITION ROMMET. FURNITURE GE\E.AL \OTES 1. LABEL ALL J-BOXES, "TELEPHONE SYSTEM". 2. ALL TELEPHONE CONDUIT SHALL BE MANDRELED, BRUSHED, AND EQUIPED WITH PULL TAPE. 1/2" MIN., UNLESS OTHERWISE NOTED. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THRU A20 FOR IDENTIFICATION OF PROGRAM AREAS. 4. INSTALL 1/2" C.O. (ONLY) TO NOTED LOCATIONS FROM SECURED PROGRAM TELEPHONE ROOM FOR STU 3 AND SECURED FACSIMILE COMMUNICATION LINES. 5. EXACT LOCATION OF GROMMET INSTALLATION WILL BE DETERMINED BY THE LOCATION OF FURNITURE. 6 > REFER TO DETAIL 7, SHEET E502 FOR TYPICAL PHONE GROMMET INSTALLATION. 7. FLOOR PENETRATION: (PROGRAM AREAS ONLY) A. INSTALL POWER GROMMET A MINIMUM OF 6" EDGE TO EDGE FROM THE DATA AND/OR TELEPHONE GROMMET. B. INSTALL DATA GROMMET A MINIMUM OF 3' FROM TELEPHONE GROMMET. 8. POLE SEPARATION: (PROGRAM AREAS ONLY) A. INSTALL POWER POLE A MINIMUM OF 6' EDGE TO EDGE FROM THE DATA AND/OR TELEPHONE POLE. B. INSTALL DATA POLE A MINIMUM OF 3' FROM TELEPHONE POLE. 9 > PROVIDE WIREMOLD G-4000 RACEWAY FROM SPACE BELOW FLOOR TO SPACE ABOVE FLOOR; EXTEND 3" INTO EACH SPACE. SURFACE MOUNT, CENTERED ON COLUMN FACE. PROVIDE GROMMET MATERIAL AROUND ENTIRE EDGE OF EACH OPENING. GROUND RACEWAY ABOVE CEILING TO NEAREST BUILDING STEEL WITH #12 WIRE. 110 > 4" x 4"' x 36 PULL BOX. (TYPICAL) CO\SRUCTIO\ \OYES 1. PROVIDE AND INSTALL CONDUIT, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. DATA CABLING TO BE PROVIDED BY OTHERS, NO HOME -RUNS SHALL BE ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE-ROUTED TO AREA BORDERED E./W. BY GRIDLINES A-C/11.5-12.6 AND N./S. BY GRIDLINES B.8-C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN -USE RACEWAY IS MINIMIZED. PROVIDE AND INSTALL SURFACE MOUNT ANALOG PHONE LINE DROPS DISTRIBUTED AMONG THE LOCATIONS SHOWN. EXACT PLACEMENT OF ANALOG PHONE DROPS TO BE COORDINATED WITH ROOM FURNITURE PLACEMENT. PROVIDE AND INSTALL DUAL CIRCUIT ANALOG PHONE FILTERS, MOUNTED HIGH ON THE OUTSIDE WALL, ACROSS EACH DATA FILTER PLATE. SEE DRAWING E529 FOR FILTER MOUNTING DETAILS. PROVIDE AND INSTALL HVAC COMM. FILTER MOUNTED HIGH ON THE OUTSIDE WALL ACROSS EACH DATA FILTER PLATE. PROVIDE AND INSTALL SURFACE MOUNT SECURE TELEPHONE LINE DROP DISTRIBUTED AMONG THE LOCATIONS SHOWN. EXACT PLACEMENT OF ANALOG PHONE DROPS TO BE COORDINATED WITH � ROOM FURNITURE PLACEMENT. PROVIDE 18" OF EXTRA SPACE ON ROOM FILTER PLATE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 ELECTRICAL MASTER TELEPHONE SECOND FLOOR 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 COL. A-F/14-20 CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL C DATE 11.27.18 SHEET 2E362 JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG No. 9-08-2E362 DEPT. N 0) co 0 SYM B B C 12 (TYP) I3> (TYP) I4> (TYP) p► DATA FILTER PLATE - DATA FILTER PLATE j 3/4" C.O. 6—FIBE 3/4" C.O. TO NETWORK CABINET 3/4" C.O. TO NETWORK CABINET DATA FILTER PLATE 3/4" C.O. REVISION REVISION DRAWING ROOM 21E15/21E16 MOD 9-08.2 TENANT IMPROVEMENT J#1001694472 W5563002 BY KOKOCZKA SANTOS CASNE WAVEGUIDE<3 6—FIBER WAVFGUIDF DATA FILTER PLATE DATA FILTER PLATE 3/4" C.O. TO NETWORK CABINET 4 APPROVED RB VAVREK CEC DATE 3/3/92 5/24/05 11.27.18 SYM 0 1 C 4" C. NETWOR CABLE TRAY MOUNTED IN THESE PARTIAL SECOND FLOOR PLA\ REVISION BY APPROVED DATE 9 >4" C.O. TYPICAL 21 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE CABLE TRAY SCHEDULE ITEM MFG ITEM NO. DESCRIPTION P—W # 2401 4" X 6" CABLE TRAY W/9" RUNG © P—W # 2401 4" X 12" CABLE TRAY W/9" RUNG P—W # 2401 4" X 18" CABLE TRAY W/9" RUNG 4 P—W #-0118-12 18" TO 12" REDUCER SERIES 1 © P—W #-0118-06 18" TO 6" REDUCER SERIES 1 6 P—W #-0112-06 12'1-0 6" REDUCER, SERIES 1 0 P—W #9012-12 12" ELBOW WITH 12" RADIUS 8 P—W #9012-18 18" ELBOW WITH 12" RADIUS g P—W #2012-12 12" TEE WITH 12" RADIUS 10 P—W #2012-18 18" TEE WITH 12" RADIUS REPRESENTS END OF CABLE TRAY DRAWN KOKOCZKA REFERE\CE NAWI\GS 9-08—E527 9-08—E528 9-08—E529 CO\STUCTION \OTES SYM 30LS LEGEND WALL/PARTITION TYPES: ■assess STC 45 STC 45 AND PROGRAM PERIMETER STC 50 AND PROGRAM PERIMETER SEE SHEET A37 FOR DETAILS OF WALL & PARTITION CONSTRUCTION DETAILS. [ ] INDICATES RAISED FLOOR DATA GROMMET. OD INDICATES DATA SERVICE POLE. — 4" IMC DATA CONDUIT 6" X 6" X 12" PULLBOX WITH CONTINUOUS HINGED COVER AND HASP. PROVIDE AND INSTALL CONDUIT, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. DATA CABLING TO BE PROVIDED BY OTHERS, NO HOME —RUNS SHALL BE' ALLOWED TO PASS THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE—ROUTED TO AREA BORDERED E./W. B GRIDLINES A—C/11.5-12.6 AND N./S. BY GRIDLINES B.8—C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN —USE RACEWAY IS MINIMIZED. PROVIDE AND INSTALL SURFACE MOUNT BEN DATA DROPS DISTRIBUTED AMONG THE LOCATIONS SHOWN. EXACT PLACEMENT OF DATA DROPS TO BE COORDINATED WITH ROOM FURNITURE PLACEMENT, PROVIDE AND INSTALL SURFACE MOUNT BEN DATA DROP FOR HALLWAY CAMERA, BOX FOR DROP TO BE MOUNTED XX" A.F.F. PROVIDE AND INSTALL SECURITY CONDUITS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE FROM BADGE READER TO NETWORK CABINET. PROVIDE PULL STRING FOR CONDUCTOR INSTALLATION BY OTHERS. BADGE READER PROVIDED BY OTHERS, PROVIDE AND INSTALL DATA FILTER PLATE. PROVIDE AND INSTALL 6—FIBER WAVEGUIDE FILTER MOUNTED HIGH ON THE OUTSIDE WALL ACROSS EACH DATA FILTER PLATE. COORDINATE NETWORK FIBER PULL THROUGH WAVEGUIDE WITH MECHANICAL INSTALLER. PROVIDE 18" OF EXTRA SPACE ON ROOM FILTER PLATE DATE CHECKED KUHLMAN -ENGIN tk KOKOCZKA CHECKED SUBTITLE KEY PLAN NO SCALE. DATA FILTER PLATE GENERAL \OTES 1. CABLE TRAY MOUNTED UNDER RAISED FLOOR. 2. CABLE TRAY MOUNTED AT 6" ABOVE SLAB. 3. REFER TO DETAIL ON SHEET 1E410 FOR CABLE TRAY MOUNTING SUPPORT DETAIL. REFER TO DETAIL ON SHEET 1E412 FOR DATA CABLE ENTRANCE DETAIL. REFER TO DETAIL 7, SHEET E502 FOR TYPICAL DATA GROMMET INSTALLATION. 6. EXACT LOCATION OF GROMMET INSTALLATION DETERMINED BY THE LOCATION OF FURNITURE. 7. REFER TO DETAIL 6, SHEET E502 FOR SPECIAL CONDUIT INSTALLATION REQUIREMENTS AT PROGRAM BOUNDARIES. REFER TO SHEETS A6 THROUGH A14 FOR IDENTIFICATION OF PROGRAM AREAS. 8 > PROVIDE WIREMOLD G-4000 RACEWAY FROM SPACE BELOW FLOOR TO SPACE ABOVE CEILING; EXTEND 3" INTO EACH SPACE. SURFACE MOUNT, CENTERED ON COLUMN FACE. PROVIDE GROMMET MATERIAL AROUND ENTIRE EDGE OF EACH OPENING. , GROUND RACEWAY ABOVE CEILING TO NEAREST BUILDING STEEL WITH #12 WIRE. DATA CONDUITS: 9 > 4"C TO CONTAIN 4 — 1" CARLON OPTIC—GARD CONDUITS. 10. COLOR CODING OF CONDUIT CONFORMS TO THE CHART BELOW: FLOOR BAND 1 BAND 2 NUMBER & COLOR QUADRANT COLOR BAND 3 SECURITY STRIPE #1 BLUE NW — YELLOW NE — GREEN SW — PURPLE . SE — ORANGE RED — EVERY 5 FEET (ONLY IN PROGRAM AREA, & 3rd FLR SWITCHROOM.) #2 WHITE NW — YELLOW NE — GREEN SW — PURPLE SE — ORANGE RED — EVERY 5 FEET (ONLY IN PROGRAM AREA, & 3rd FLR SWITCHROOM.) #3 BLACK NW — YELLOW NE — GREEN SW — PURPLE SE — ORANGE RED — EVERY 5 FEET (ONLY IN PROGRAM AREA, AND SWITCHROOM.) #4 ORANGE N — YELLOW S — ORANGE NO BAND #5 GREEN N — YELLOW S — ORANGE NO BAND COLOR BANDS ARE 1 NO BANDING IN THE BAND 1, AT THE 3rd BAND 2, AT THE 3rd ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 LAN SYSTEM - SECOND FLOOR r rf 00 FPPVIPOI APR 12 2019 City of TWWW " WIDE, PAINTED NOT TAPED VERTICAL CHASE. FLOOR SWITCHROOM END ONLY. FLOOR SWITCHROOM END ONLY. RECEIVED) CITY OF T UKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUI7E 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNECOM • JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL DATE 11.27.18 TITLE 9-08.2 TENANT IMPROVEMENT BUILDING 09-08 ELECTRICAL MASTER COL. A—F/14-20 SHEET 2E412 JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG NO. 09-08-2E412 LOW VOLTAGE LIGHTING CONTROL SCHEDULE — NORTH HALF LOW VOLTAGE LIGHTING CONTROL SCHEDULE — SOUTH HALF m M W I co 0 0 0 i c 0 0 E 2 L.V. LIGHTING CONTROL PANEL LTG. /CKT. PANEL NO. AREA CONTROLLED PLAN SHT. DWG. REF. SWITCHING REMARKS PANEL N0. LOCATION RELAY N0. LOCATIONS) DET, N0. SWITCH REF. RC2C6 RC2D6 2C6-3/Ia CORRIDOR (C/3-10) 2E11�1 2EIZ C4, CIO 1 A2 R2RI Al 2C6-3/3bR3 A—C/3-4 2E12 C4, C8 3 R4 1 1 1 Al R5 2C6-3/5c A—C/4-6 2E12 C4, C8 3 B2 R6 iBI R7 2C6-3/7a A-C/6-7 2E12 C4, C8 3 A2 R8 1 � i i 1 CI R9 2C6-3/9b A—C/7-9 2E11 C8, CIO 2 A2 RIO i '1 1 � � Al RII 2C6-3/Ilc A—C/9—II 2E11 C8, CIO 2 B2 R12 i � � i � BI R13 2C6-3/I3a SPARE R14 R15 2C6-3/15b SPARE RI6 R17 2C6-3/I7c SPARE RIS R19 2C6-3/I9a SPARE R20 R21 2C6-3/21b SPARE R22 j 1 R23 2C6-3/23c SPARE R24 RI 2D6-3/la D—E/2-3 2E12 D4, DIO 6 F2 R2 1 1 i 1 1 FI 2D6-3/3b D—F/2-4 2E12 D4, DIO 6 E2 RR3 4 � El 2D6-3/5c D—F/4-6 2E12 D4, DIO 6 D2 RR5 6 � 1 DI R7 2D6-3/7a D—F/6-7 2E12 D4, DIO 6C2 R8 1 I 1 1 i CI R9 2D6-3/9b D—F/7-9 2E11 D4, DIO 6 B2 RIO 1 i + + � BI RII 2D6—I/Ilc D—F/9—I10 2E11 D4, DIO 6 A2 R12 � 1 + � � Al R13 2D6-3/13a C—D/8-9 2E11 C9, D9 I A2 R14 � t + � � Al RI5 2D6-3I/I5b C—D/2-3 2E12 C3, D2 1 A2 RI6 1 j � � � Al RI7 2D6-3/I7c SPARE R18 i 1 R19 2D6-3/19a SPARE RZ0 i '1 R21 2D6-3I/21b SPARE R22 R23 2D6-3/23c SPARE R24 1 t SK-2 Al A2 SWITCH LAYOUT DETAIL #I SYM REVISION SK-22 AI A2 BI B2 SWITCH LAYOUT DETAIL #2 BY APPROVED SK-23 Al A2 BI B2 CI C2 DATE SWITCH LAYOUT DETAIL #3 SYM REVISION SK-24 Al A2 BI B2 CI C2 DI D2 SWITCH LAYOUT DETAIL #4 BY APPROVED DATE A RECORD DRAWING JMK MJB 10.01.90 B 9-08.2 TENANT IMPROVEMENT W5563002 CASNE EEK 11.27.18 10/ SK-25 L.V. LIGHTING CONTROL PANEL LTG. PANEL CKT. NO, AREA CONTROLLED PLAN SHT, DWG, REF, SWITCHING REMARKS PANEL N0, LOCATION RELAY �C. INN 1E , 0 W T .EF RC2CI5 RC2DI5 RI 2CI5-3/la C/I4—I8 2E12 CII 6 F2 R2 1 1 1 1 1 FI R4 1 1 R5 2CI5-3/5c SPARE R6 1 1 R7 2CI5-3/7a SPARE R9 2CI5-3/9b A—C/I2—I4 2E11,2E12 CII, CI7 6 B2 RIO 1 1 1 1 1 BI _ �- ;, RI2 1 1 1 1 1 Al RI3 2CI5-3/I3a C—D/I2-13 2E11 C13 I A2 RI5 2CI5-3/9b SEE REMARKS 2E11,2E12 A.3/13.25 1 A2 .25/13,25-14,75 RI6 1 1 1 1 1 Al —A.25/I1.2-12.1 RI8 1 1 1 1 1 Al R19 2CI5-3/IIc SEE REMARKS 2E11 A,3/I1.75 1 A2 A—A.25/10,75—II,5 R20 1 1 1 1 1 Al R2I 2CI5-3/2Ib SPARE R22 1 1 R23 2CI5-3/23c SPARE R24 1 1 RI 2DI5-3/Ia C.5—D/I7,5—I9 2E10 C.5, 17.5 1 A2 R2 1 1 1 1 1 Al R3 2DI5-3/3b D—F/I6—17 2E10 DI7 I A2 R4 1 1 1 1 1 Al R5 2DI5-3/5c D—F/I5-17 2E10 DII, DI5 4 A2 R6 1 1 1 1 1 Al R7 2DI5-3/7a D—F/I4-15 2E10 DII, D15 4 B2 R8 1 1 1 1 1 BI R9 2DI5-3/9b D—F/I2-14 2E11 DII, DI5 4 C2 RIO 1 1 1 1 1 CI RII 2DI5-3/IIc D—F/II-12 2E11 DII, DI5 4 D2 RI2 1 1 1 i 1 DI R13 2DI5-3/13a SPARE R14 1 1 R15 2DI5-3/I5b SPARE R16 i 1 R17 2DI5-3/I7c SPARE R18 1 1 R19 2D15-3/19a SPARE R20 1 1 R2I 2D15-1 3/2Ib SPARE - QEmvl8WWo Foir O PAANEWTH R22 R23 2D 15-3/23c SPARE APR 12 2019 R24 1 1 BUILof Tukwila DING DIVISION Al A2 BI B2 CI C2 DI D2 El E2 SWITCH LAYOUT DETAIL #5 SK-26 (TYP) (TYP) Al A2 BI B2 CI C2 DI D2 El E2 FI F2 SWITCH LAYOUT DETAIL #6 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DATE DRAWN R. HAMMET DATE CHECKED W. KUHLMAN SUBTITLE CONSTRUCTION NOTES 1. TIE CIRCUITS INTO SHOWN POSITIONS TO CONTROL LIGHTS IN AREAS ADJACENT TO CLOSED ROOMS BETWEEN A—C/11.5-14.3 RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER NOTES I. REFER TO SHEETS 2E10, 2E11 & 2E12 FOR PLANS SHOWING THE CONTROLS LISTED ON THIS DRAWING, 2, REFER TO SHEET E3I0 FOR LOW VOLTAGE LIGHTING CONTROL DIAGRAM. ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 LOW VOLTAGE LIGHTING CONTROL SCHEDULE - SECOND FLOOR PASS & SEYMOUR CATALOG NUMBERS INCLUDE WALL PLATE AND MOUNTING STRAPS. ALL LOW VOLTAGE MOMENTARY CONTACT SWITCHES ARE PASS & SEYMOUR CATALOG NUMBER 10911. CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SURF 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL 3 DATE 11.27.18 ENGINEER R. HAMMET CHECKED J. KOKOCZKA APPROVED M. BENSTON APPROVED D. SEPTELKA 10.01.90 TITLE 9-08.2 TENANT IMPROVEMENT BUILDING 09-08 ELECTRICAL COLA—F/1-20 SHEET E311B JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG No. 09-08—E311B DEPT. M W 0 0 I 0 i on 0 0 E 0 I N CO 0 I 0 G) 0 03 • 0 U 0 0) W c 0 0 0 a LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING LAMPS VOLTAGE BALLAST INPUT WATTS MANUFACTURERS CATALOG SERIES NUMBER REMARKS SYMBOLS 2' x 4' RECESSED DETAIL 1 34 WATT 277 V 114 LITHONIA OPTIMAX FURN. IN FACTORY WIRED Al FLUORESCENT TROFFER THIS SHT. F4OCW AVERAGE 2PMOGB 340 27S 277 TANDEM BALLASTED -3,4 TANDEM BALLASTED 2750 LUM PER FIX. -ES-LST-GLR PAIRS w/ 3 2-LAMP 0 (OWNER) BALLASTS PER PAIR 2' x 4' RECESSED DETAIL 1 34 WATT 277 V 114 LITHONIA FURN. IN FACTORY WIRED /TA F FLUORESCENT TROFFER THIS SHT. F4OCW AVERAGE 3" DEEP, 24 CELL PARAMAX TANDEM BALLASTED TANDEM BALLASTED 2750 LUM ,4 PER FIX. 2PM3GB 340 24S 277 PAIRS w/ 3 2-LAMP (OWNER) -ES-LST-GLR BALLASTS PER PAIR 2' x 4' RECESSED - DETAIL 1 34 WATT 277 V 120 LITHONIA OPTIMAX 1 2-LAMP AND 1 61 FLUORESCENT TROFFER THIS SHT. F4OCW 2MPOGB 340 27S 277 1-LAMP BALLAST 0 4,4 DEDICATED BALLASTS 2750 LUM -ES-GLR (OWNER) 2' x 4' RECESSED DETAIL 1 34 WATT 277 V 120 LITHONIA 1 2-LAMP AND 1 B2 FLUORESCENT TROFFER THIS SHT. F4OCW 3" DEEP, 24 CELL PARAMAX 1-LAMP BALLAST -3,4 DEDICATED BALLASTS 2750 LUM 2PM3GB 340 24S 277 (OWNER) -ES-GLR 1' x 4' SURFACE CEILING 34 WATT 277 V 76 HOLOPHANE 1 2-LAMP BALLAST 0 FLUORESCENT WRAPAROUND SURFACE F4OCW PRISMAWRAP Z,4 _,�_ DEDICATED BALLAST 2750 LUM K7100-4-277 (OWNER) 2' x 2' RECESSED SIM. TO 34 WATT 277 V 76 LITHONIA 1 2-LAMP BALLAST D1 FLUORESCENT TROFFER DETAIL 1 F4OCW/U/6 -3,4 DEDICATED BALLAST THIS SHT. 2600 LUM 3" DEEP, 12 CELL PARAMAX 2PM3GB 2U40 12S 277 u (OWNER) -ES-GLR 2' x 2' RECESSED SIM. TO 34 WATT 277 V 76 LITHONIA 1 2-LAMP BALLAST 72 FLUORESCENT TROFFER DETAIL 1 F4OCW/U/6 2SPG 2U40 Al2.125 QQ 14 DEDICATED BALLAST THIS SHT. 2600 LUM -ES-GLR A-12 DIFFUSER (OWNER) .125" 2' x 2' RECESSED SIM. TO 34 WATT 120 V 90 LITHONIA 2-LAMP DIMMING BALLAST IITA FLUORESCENT TROFFER DETAIL 1 F4OCW/U/6 2,4 DEDICATED BALLAST THIS SHT. 2600 LUM 3" DEEP, 12 CELL PARAMAX 2PM3GB 2U40 12S 120 UNIVERSAL 502A-TC-P, ADVANCE DIM240-H-TP OR u (OWNER) -ES-GLR G.E. 8G5007 ONLY 2' x 2' RECESSED SIM. TO 34 WATT 277 V 76 LIGHTOLIER 1 2-LAMP BALLAST 154 FLUORESCENT TROFFER DETAIL 1 F4OCW/U/6 LYTECEL HP 2,4 DEDICATED BALLAST THIS SHT. 2600 LUM NO. 67471UV-GLR 1-1 /2"X1-1 /2"X1" CELLS (OWNER) 9" DIAMETER CEILING 13 WATT 277 V 30 GOTHAM © FLUORESCENT RECESSED 13TT AF 13TT 9AR 277 HPF DOWNLIGHT w/CLEAR 0 OPEN REFLECTOR POLE MOUNTED POLE 100 WATT 277 V 120 STERNER /T\ HIGH PRESSURE SODIUM HPS EX20A283N100S277C 2z-L190 FIXTURES (2 HEADS) WITH CENTRECON POLE .� WITH POLE NO. SBQ5-313 POLE MOUNTED POLE 70 WATT 277 V 85 STERNER iT\ HIGH PRESSURE SODIUM HPS EX20A283N70S277C 2-,0 FIXTURES (2 HEADS) WITH CENTRECON �p� WITH POLE POLE NO. SBQ5-313 2' x 4' RECESSED DETAIL 1 32 WATT 277 V 68 LITHONIA AVANTE 2-LAMP ELECTRO. BALLAST /71 \ FLUORESCENT METAL DIFFUSER THIS SHT. 32WT8 2AV GV 2 32 MDR ROUND HOLES 3,500K MVOLT ADOPRL HTC GMF ADVANCE #I0P2S32SC COOL -WHITE METAL HALIDE CEILING 175 WATT 277 V 200 LITHONIA fT\ SQUARE RECESSED MET. HAL. LASH12-175MP-RMCLB-SF 175, DOWN LIGHT MS175 DL FIXTURE /C/HOR 1' x 4' PENDENT PENDANT 34 WATT 277 V 76 COLUMBIA 1 2-LAMP BALLAST fr\ INDUSTRIAL FLUORESCENT 9 FT F4OCW MODEL-17. 2 10% UPLIGHT moo- ,4 AFF 2900 LUM CAT. NO. F1-UC-240-M17 (OWNER) RECESSED INCANDESCENT CEILING 75 WATT 120 V N/A LIGHTOLIER LABYRINTH LIGHTING /Y\ DOWNLIGHT RECESSED PAR-30 B7705-BK/B600 INSTALL IN R.F. BOXES 75 w/NO. 1968 0 SOCKET EXTENDER HPS SURFACE WALL 70 WATT 277 V 85 HOLOPHANE WALLPACKETTE SURFACE HPS WP2A070HP27BZ 22, WXATHER-RESISTANT XX HPS STANCHION STANCHION 70 WATT 277 V 85 CROUSE-HINDS © WEATHER-PROOF 1-1/4" C HPS CHAMP HID 2_, FIXTURE 8' TO BOTTOM NO. VMVSJ070GP ° w/GLOBE & GUARD OF FIXTURE HPS WALL 70 WATT 277 V 120 STERNER P\ WALL SURFACE HPS EX20A103N100S277C ,100, FIXTURE STYLE M g FLUORESCENT EXIT SIGN CEILING 6 WATT 277 V 20 PRESCOLITE PROFILE SERIES EX1 GREEN LETTERS ON WHITE SURFACE F6T5 CATALOG NO. 74322 &5 BACKGROUND, STENCIL STYLE, COMPACT UNIVERSAL ARROW, TWIN FACE FLUOR. FLUORESCENT EXIT SIGN WALL 6 WATT 277 V 20 PRESCOLITE PROFILE SERIES Ala GREEN LETTERS ON WHITE RECESSED F6T5 CATALOG NO. 74412 5 BACKGROUND, STENCIL STYLE, COMPACT NO ARROW, SINGLE FACE FLUOR. 4FT WALL 32 WATT 120 V 64 LITHONIA MOUNT ON WALLS R1 TWO TUBE SURFACE T8 NO. DM232-120GEB OF ELEVATOR PITS =o= FLUORESCENT DAMP LOCATION/IMPACT RESISTANT FLUORESCENT DOWNLIGHT CEILING 13 WATT 277 V 39 PRESCOLITE /7-\ w/SPECULAR CLEAR ALZAK RECESSED 13TT CRF813-B572 (277V) HPF REFLECTOR WITH BLACK COMPACT MILLIGROOVE BAFFLE FLUOR. 6" SQUARE x 4' WALL 34 WATT 277 V 76 GUARDCO FOCUS ONE /7\ FLUORESCENT FIXTURE SURFACE F4OCW S6ODWL-240RS-04 2,-: ,4 6" ABOVE 2900 LUM -PC4-277-FP-CL ` 2' 4' RECESSED LED UNV 36 FINELITE# / \ x TROFFER CEILING RECESSED 4743 LUM FINELITE# HPRLED-A-2x4- 0-10V DIMMING 0 33 DCO-B-935-UNV-SC SYM A RECORD DRAWING B ADD NEW EXIT LIGHT C ELEVATOR CHANGE D REVISION RAPTOR SIMULATION LAB (RSL) BY JMK J#76270500 DARCY J#53517400 J#16065600 TEB SANTOS APPROVED MJB MEHTA VAVREK VAVREK DATE SYM 10/01/90 F 7/12/96 10/14/03 10/23/07 REVISION 9-08.2 TENNANT IMPROVEMENT 86062 BY CASNE APPROVED EEK FROM LIGHTING PANELBOARD DATE 11.27.18 LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING LAMPS VOLTAGE BALLAST INPUT S MANUFACTURERS CATALOG A REMARKS SYMBOLS 2' x 4' RECESSED LED B5 TROFFER CEILING RECESSED 4278 LUM UNV N/A 0 FRK6EASAMJIN# 0454-0E10US-120-277-10V DIMMING 0 2' x 4' RECESSED LED BB TROFFER 45 CEILING RECESSED 4300 LUM UNV N /A PHILIPS DAY-BRITE# 2FGG43L8404DSUNVDIM BODINE EMERGENCY DRIVER BSL310LPST 0-10V DIMMING 2' x 2' RECESSED LED BC TROFFER CEILING RECESSED 3276 LUM UNV N /A FINELITE# HPRLED-A-2x2-DCO-S-835 -UNV-SC 0-10V DIMMING 0 TUT\ 0 INCANDESCENT WALL WASHERS • TRACK 0250CL/DC 5000 LUM T-4 D.C. LITE CAPSULE TLC-6WH TS21WH CONNECTORS T44 WIREWAY COVER TS13WH BOX FEED ALL V SERIES FIXTURES RESERVED FOR VTSS ROOM LIGHTING SEE SHEET E523 /\ 2' x 4' RECESSED FLUORESCENT METAL DIFFUSER ROUND HOLES SUSPENDED 18" CABLE 32 WATT 32WT8 3,500K COOL -WHITE 277 V 68 FINELITE S8-FP-32-2T8-SC-91 W-277- AC18"-FE 2-LAMP ELECTRONIC DIMMING BALLAST ADVANCE #VEZ-2S32-SC 150 8" DIAMETER INCANDESCENT DOWNLIGHT CEILING RECESSED 150 WATT PAR-38/FL 2000 LUM 120 V N/A LIGHTOLIER NO. 7709-A2 SPECULAR BLACK ALZAK CONE X2 150, 8" DIAMETER INCANDESCENT ADJUSTABLE ACCENT LIGHT CEILING RECESSED 150 WATT PAR-38/FL 2000 LUM 120 V N /A LIGHTOLIER NO. 7776-A2 SPECULAR BLACK ALZAK CONE p--7\ 1,-34 4FT SINGLE TUBE FLUORESCENT WRAPAROUND CEILING SURFACE 34 WATT F4OCW 2750 LUM (OWNER) 277V 44 KEYSTONE NO. AD140-A-277V USED IN TELEPHONE CLOSETS WALL SCONCE 2 LAMP FLUORESCENT INDIRECT (UPLIGHT) WALL SURFACE +6'-6" 13 WATT 13TT 277V 39 LIGHTOLIER NO. 40040/974/SP277 FOR ENTRANCE TO MGMT. COMPLEX; WITH 277V BALLAST UNDERCABINET BLACK TRACK AND TRACK LIGHTS FRONT EDGE OF BOTTOM OF CABINET 9 WATT 9TT 120V 13 (EACH) LIGHTOLIER NO. 8395 TRACK AND (4) NO. 8367 LIGHTS CUT TRACK TO LENGTH OF CABINET AB 1-7 "IN USE" SIGN LETTERS ON WHITE ACRYLIC PANEL WALL RECESSED +5'-0" 7 WATT 7TT 120V 11 COLE NO. S152-"IN USE"-ROF-PL7 FOR MIC ROOMS; SEE ARCH. FOR DETAILS ON TRIMMING FIXTURE AC 1-34 4FT SINGLE TUBE FLUORESCENT WRAPAROUND CEILING SURFACE 34 WATT F4OCW 2750 LUM (OWNER) 120V 44 KEYSTONE NO. AD140-A-120V USED IN COAT CLOSETS ,\ DIRECT BURIAL LIGHT WITH ROUNDEL LENS AND CAST BRONZE HOUSING DIRECT BURIED IN TREE PLANTER 70 WATT HPS 277 V 82 KIM 5126HPS277 O BOLLARD LIGHT LIGHT GRAY ALUMINUM COLOR ELECTROLUMINESCENT EXIT SIGN 6"Hx3/4"W GREEN LETTERS BRUSHED ALUMINUM FACE WHITE BODY,SINGLE FACE ELECTROLUMINESCENT EXIT SIGN 6"Hx3/4"W GREEN LETTERS BRUSHED ALUMINUM FACE WHITE BODY, DOUBLE FACE GROUND BOTTOM OF BASE FLUSH WITH WALKWAY WALL OR CEILING WALL OR CEILING 70 WATT HPS 0.31 WATT 0.62 WATT 277 V 277 V 277 V 82 NA NA KIM SL5/70HPS277-MOD/NA-E ENERGY SMART PRODUCTS CATALOG #EL1600-WH-S ENERGY SMART PRODUCTS CATALOG #EL1600-WH-D ORIENT FIXTURE TO SHINE LIGHT TOWARD BUILDING EL CONCEPTS (206)525-1970 RICHARD S. COLLEY EL CONCEPTS (206)525-1970 RICHARD S. COLLEY 1A 277V I [220V N 3A II II OFF 'HAND f „AUTO nH --}--0 —0 PHOTO SWITCH o II o 7.7 IA B LOCATIONS: 1st FLOOR, COLUMN F12 - REFER TO SHEET 1E11 ROOF, COLUMN D9 - REFER TO SHEET RE10 o LIGHTING CONTACTOR ASSEMBLY - 6 POLE, 20 AMP, 480 VAC CONTACTOR; NEMA 12 ENCLOSURE; FUSED CONTROL CIRCUIT WITH 277/120V TRANSFORMER; HAND -OFF -AUTO SELECTOR SWITCH. SQUARE D CLASS 8903, TYPE LA-60 WITH FORM FF1T FUSED TRANSFORMER, FORM C HAND -OFF -AUTO SELECTOR SWITCH, FORM N SOLID NEUTRAL TERMINAL BLOCK AND FORM N1 ENCLOSURE GROUND LUG OR APPROVED. • PHOTO SWITCH - 1800 VA MIN. AT 277 VAC. TORK MODEL NO. 2102 OR APPROVED I Co Fw HO c • 11 N EXTERIOR LIGHTING CONTROL CABINET - WIRING DIAGRAM ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE o I DRAWN HAMMETT DATE CHECKED KUHLMAN ENGINEER HAMMETT TO LIGHTING LOADS SUBTITLE FIXTURE SUPPORT WIRE (TYP) 1/2" FLEXIBLE STEEL CONDUIT TO J-BOX (6" MAX. LENGTH) TYPICAL RECESSED FIXTURE INSTALLATION DETAIL SCALE: NONE ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 LIGHTING SCHEDULE AND DETAILS E313 E313 FIXTURE CEILING SUPPORT GRID GX7' VI ED PO Ni=RI 7'� ggril APR 12 2019 City of Tukwila 6UILDING DIVISION RECEIVED CITY OF TUKWILA FEB 252019 CEILING TILE PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL DATE 11.27.18 CHECKED KOKOCZKA APPROVED BENSTON APPROVED SEPTELKA TITLE 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 COL. (ALL) SHEET E313 JOB NO. W5563002 COMP NO. 0 E 9-08.1 TENANT IMPROVEMENT 34355 CASNE WS 10.09.18 10/01/90 ELECTRICAL MASTER DEV. CENTER DWG NO. 9-08-E313 \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008—E527.dwg DRYWALL AND PLYWOOD BACKING FILTER ENCLOSURE (BACK WALL) CONDUIT LOCKNUT POWER FILTER \IPPLE DETAIL ALL -THREAD NIPPLE RF NUT- RF GASKET SHIELD PLATE ALL -THREAD NIPPLE OPTION AND LENGTH MUST BE SPECIFIED TO FILTER MANUFACTURER. BE I ER TO BE TOO LONG RATHER THAN TOO SHORT. IRON LB CONDUIT BODY (REMOVE COVER GASKET) RIGID OR IMC CONDUIT TO PANEL. FIELD DETERMINE LENGTH AND ANGLE. #1/0 CU WIRE TO BUILDING STEEL ROOM GROUND STUD 1/2-13 BRASS THREADED ROD. MUST EXTEND AT LEAST 3" PAST WALL INSIDE AND 2" PAST PLYWOOD BACKER OUTSIDE OF ROOM. USE BRASS NUTS AND WASHERS. OUTSIDE ROOM, CONNECT #1/0 COPPER WIRE TO BUILDING STEEL. INSIDE ROOM, CONNECT #2/0 COPPER BRAID TO GROUND BAR. AC POWER FILTER: UNIVERSAL SHIELDING USC-50-2X5. 120V, 1 PHASE, 5 AMPS. EMERGENCY POWER CIRCUIT FOR EMERGENCY LIGHTS. TO 208Y/120V SOURCE • UNIVERSAL SHIELDING CORP. AC POWER FILTER. SIZE AS NOTED ON DRAWING 1E60/2E60. - USC-50-4X60: 208/120V, 3PH, 4W, 60A - USC-50-4X100: 208/120V, 3PH, 4W, 100A - USC-50-4X150: 208/120V, 3PH, 4W, 150A FILTER IS LARGE AND HEAVY, APPROX 28"X40"X17" AND 275-300LBS. • SOURCE POWER IS FED AT BOTTOM SECTION. • FILTERED POWER COMES FROM TOP SECTION. • MOUNT HIGH ON THE WALL SO IT DOESN'T INTRUDE INTO WORKING SPACE. • NIPPLE TO INSIDE IS 2" ALL THREAD - SPECIFY REQUIRED LENGTH WHEN ORDERING. • NOTE: FILTER ASSEMBLY MAY NOT BE UL LISTED. MAY NEED TO HAVE CERTIFIED BY WASHINGTON APPROVED NRTL. 3/4" PLYWOOD FOR FILTER MOUNTING, GROUND STUD SUPPORT, ETC. STRUT MAY BE ADDED ON TOP OF PLYWOOD IF DESIRED TO MOUNT FILTER. E527 A504 GROUND STUD ASSEMBLY INPUT POWER FILTER 208/120V, 30, 4W, XXA 2 E527 E529 OTHR \OTES: • WALL HEIGHT DRAWN IS MUCH SHORTER THAN ACTUAL WALL. • INSTALL FILTER WHEN OUTSIDE DRYWALL AND PENETRATION PLATE HAVE BEEN INSTALLED (PRIOR TO INTERIOR DRYWALL OR FOILING). • GROUND PLATE ONLY NEEDS TO BE 1 STUD CAVITY WIDE (AT FILTER ALL -THREAD NIPPLE). • GROUND STUD TO BE INSTALLED IN SAME PLATE AS POWER FILTER. • HOLES IN EXTERIOR WALL/BACKING TO BE LARGE ENOUGH TO ALLOW REMOVAL OF PENETRATION ASEEMBLIES FOR MAINTENANCE AND TO ALLOW PENETRATIONS TO BE PERFECTLY PERPENDICULAR TO THE PLATE. FOAM AROUND GAP IN PLYWOOD AFTER PENETRATIONS ARE INSTALLED. POWER FILTER SCALE: NONE SOU\D STUD ASSE THREADED ROD BRASS NUTS BRONZE LOCKWASHER 1/2" RING TERMINAL BRASS WASHER DRYWALL AND PLYWOOD BACKING -RF GASKET BRASS NUT SHIELD PLATE BRASS WASHER BRASS NUT BRASS WASHERS 1/2" RING TERMINAL BRONZE LOCKWASHER BRASS NUT NUT AGAINST PLYWOOD TO BE FINGER TIGHT (ONLY FOR ROD STABILITY). ALL OTHER MUST BE WRENCH TIGHT. RF GASKET TO FILL VOID BETWEEN PLATE HOLE AND ROD. APPLY RF CAULK TO THREADS OF NUT BEHIND SHIELD ONCE PROPER POSITION HAS BEEN ESTABLISHED. & PA\EL #2/0 CU BRAID TO GROUND BAR 3/4" ALL -THREAD NIPPLE - IRON LB FITTING W/0 GASKET 3/4"GRS, 2#12, #12G TO EMERGENCY LIGHTS 2" ALL -THREAD NIPPLE, 4#4, #10G - IRON LB FITTING W/0 GASKET E 27 E5 7 PENETRATION PLATE 2"GRS 208Y/120V PANEL STEEL CHANNEL v0U\TI\G (Th 1E9A,1E60,1E360,1E410,2E362,2E412IE527 61 STUD WALL (I \SIDE ICD oov VIEW) r r r ACOUSTIC SEAL AROUND BACK SIDE OF PLATE PERIMETER TO SEAL GAPS IN SPACER STOCK AND PLATE. • 1/8" THICK GALVANIZED STEEL FEED THROUGH PLATE. MOUNT WITH #10 SELF TAPPING STAINLESS STEEL SCREWS INTO STUD THROUGH SQUARE SPACER STOCK. • SCREW INTO EACH STUD AND SPACER SEGMENT WITH AT LEAST 2 SCREWS PER SQUARE SPACER SEGMENT. • COUNTERSINK SCREW HOLES AT ANGLE MATCHING SCREW HEAD SO HEADS ARE FLUSH AND TIGHT. • COVER HALF OF STUD WIDTH (3/4") SO DRYWALL CAN ALSO BE SCREWED TO STUD. • 1/2" SQUARE STAINLESS OR GALVANIZED STEEL SPACER AROUND PERIMETER OF PLATE AND ANY INTERMEDIATE METAL STUDS. • SMALL GAPS TO ADJACENT PIECES (SEGMENTS OR CORNERS) ARE OK. • DRILL CLEARANCE HOLES FOR SCREWS. OTHER \OTES: • PENETRATION PLATE MINIMUM DIMENSION TO BE 8" TO ALLOW ROOM FOR SHIELD FOIL AND TAPE TO OVERLAP WHILE STILL HAVING ROOM FOR PENETRATIONS. • IN GENERAL, SMALLER PENETRATIONS SHOULD BE ON 4" CENTERS WITH CENTER AT LEAST 4" FROM THE EDGE OF THE PLATE. LARGER PENETRATIONS (2" PIPE OR LARGER) SHOULD USE A LARGER SPACING. • WIDTH AND HEIGHT OF PLATE TO BE SIZED FOR PLANNED NUMBER OF PENETRATIONS AND LIKELIHOOD OF ADDITIONAL FUTURE PENETRATIONS. • PLATE MUST BE FULLY SUPPORTED ALONG ITS PERIMETER (USE SPACER STOCK). TEVPEST ROOM WALL PENETRATIO\ PLATE DETAIL rA1 SCALE: NONE E527,E529 E527 LEGEND/SCHEDULE: GENERAL \OTES: 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN. ON SHEETS E2 AND E3 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWI \GS: STUD (SIDE VIEW) ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 9-08-1E9A 9-08-1 E60 9-08-1 E360 9-08-2E362 9-08-1 E410 9-08-2E412 9-08-E528 9-08-E529 SIGNAL REFERENCE GRID FIRST FLOOR 208Y/120V POWER PLAN TELEPHONE FIRST FLOOR TELEPHONE SECOND FLOOR LAN SYSTEMS - FIRST FLOOR LAN SYSTEMS - SECOND FLOOR SHIELDING AND TEMPEST ROOM REQUIREMENTS SHIELDING AND TEMPEST ROOM REQUIREMENTS CO\STUCTIO\ NOTES: PROVIDE PANELBOARD, GROUNDING PLATE, FOIL GROUNDING ASSEMBLY AND OTHER FEATURES INDICATED IN THE DETAIL IN EACH OF THE ICD-705 ROOMS. PROVIDE PENETRATION PLATE ASSEMBLY AT EACH WALL PENETRATION IN EACH OF THE ICD-705 ROOMS, AS SHOWN. PROVIDE POWER FILTER AND ASSOCIATED HARDWARE REQUIRED TO MOUNT IT TO THE OUTSIDE OF EACH ICD-705 ROOM WALL. SEE ARCHITECTURAL DRAWINGS FOR ACCURATE WALL, CEILING, AND RF-SHEILINDING CONSTRUCTION DETAILS. RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE COM JOB. NO. 181-093 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE SHIELDING & TEMPEST ROOM REQUIREMENTS CURRENT REVISION W5563002 SYMBOL DATE A 11.27.18 oo - 9-08.1 TENANT IMPROVEMENT 34355 CASNE WS 07.24.18 A 9-08.2 TENANT IMPROVEMENT W5563002 CASNE EEK 11.27.18 APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL 9-08.2 TENANT IMPROVEMENT BUILDING 09-08 SHEET E527 JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG No. 09-08-E527 OTHER \OTES: LEGE\D/SCHEDULE: \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008—E528.dwg o DRILL AND TAP 1/4-28 HOLES INTO PLATES AND DOOR FRAME. ATTACH RING TERMINALS WITH 1/4-28 BOLT AND LOCK WASHER. REMOVE PAINT ON DOOR FRAME WHERE RING LAYS. ° RUN GROUNDING JUMPERS TO THE PENETRATING PIPES, NOT THE SLEEVES (SLEEVES ARE ALREADY GROUNDED TO THE PLATE). o HVAC DUCT HAS NON-METALLIC ISOLATOR SO INTERIOR DUCTS ARE NOT TO BE GROUNDED. 2/0 EQUIVALENT BRAID 1/4" RING TERMINAL BOTH ENDS #4 XHHW 1/4" RING TERMINAL TO PLATE, BARE END TO GROUND CLAMP. o USE PIPE CLAMP FOR 5/8" TUBE AND 1/2" OR LARGER PIPES. o USE SPLIT BOLT FOR 3/8" TUBE. TO EMERGENCY LIGHTS 4—PLEX RECEPTACLE 4'-0" DATA FILTER PLATE FIBER FUTURE WAVEGUIDE PENETRATIONS ETHERNET ETHERNET ETHERNET FILTER FILTER FILTER r--Ir--Ir--I I II II I I II II I L_J L_J L_J Or C�crl PIPE PIPE PIPE CN FUTURE PENETRATIONS ETHERNET ETHERNET ETHERNET FILTER FILTER FILTER ®II ®II I II II I L_J L_J L_J 208Y/120V PANEL 10 POWER FILTER PLATE ® I ® I PIPE FUTURE FIRE WAVEGUIDE A FILTELARMR EMERGENCY 1 I POWER FILTER I I CO 0 1'-4" L _ J 12" FUTURE PENETRATIONS ETHERNET ETHERNET ETHERNET FILTER FILTER FILTER II II ® I II II I L_J L_J L_J IHVA 'PHONE' 'PHONE' I FILTER 1 I FILTER I I FILTER 0 0 0 0 0 0 0 0000000 ,0 [1/4 X 2 X 12,'¼ 18 (7/16") HOLE `, GROUND BAR -.. II II 1 II II I _JL_JL_J 39-3/4" '--POWER FILTER DOOR FRAME SEE RESPECTIVE PLAN VIEW DRAWINGS FOR EXACT NUMBER OF FILTERS FOR EACH CLOSED ROOM AND MAKE PENETRATIONS ACCORDINGLY. (NOT ALL CLOSED ROOM'S HAVE THE SAME DATA FILTER PLATE PENETRATIONS) 00V 30\DING SCALE: 1-1 /2"=1'-0" 1 E60,1 E360,1 E410,2E362,2E412 E528 ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 CENRAL NOTES: 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERE\CE NAWI\GS: 9-08-1 E9A 9-08-1 E60 9-08-1 E360 9-08-1 E410 9-08-2E362 9-08-2E412 9-08-E527 9-08-E529 SIGNAL REFERENCE GRID FIRST FLOOR 208Y/120V POWER PLAN TELEPHONE FIRST FLOOR LAN SYSTEMS - FIRST FLOOR TELEPHONE SYSTEMS - 2ND FLOOR LAN SYSTEMS - 2ND FLOOR SHIELDING AND TEMPEST ROOM REQUIREMENTS SHIELDING AND TEMPEST ROOM REQUIREMENTS CO\S-RUCTIO\ NOTES: APR 12 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER GRAPHIC SCALE: SCALE: 1-1/2"= )1 CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN C. ALLISON DATE SUBTITLE SHIELDING & TEMPEST ROOM REQUIREMENTS CURRENT REVISION W5563002 SYMBOL A DATE 11.27.18 0 co 9-08.1 TENANT IMPROVEMENT 34355 CASNE WS 07.24.18 A 9-08.2 TENANT IMPROVEMENT 34355 CASNE EEK 11.27.18 APPROVED BY DEPT. DATE CHECKED D. TOWNSEND ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL 9-08.2 TENANT IMPROVEMENT BUILDING 09-08 DEV. CENTER, WA SHEET E528 JOB NO. W5563002 COMP NO. DWG NO. 09-08-E528 LECE\D/SCHEDULE: \BABBAGE\ Documents \ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008—E529.dwg FI3ER WAVEGUIDE DETAIL WGF-6 WAVEGUIDE RF NUT RF GASKET SHIELD PLATE RF NUT WCN-6 COUPLING NUT WEB6 EXTENSION TUBE NUT (OPTIONAL) WASHER (OPTIONAL) DRYWALL AND PLYWOOD BACKING WET-18A TUBE MAY BE BEIIER IF IT CAN BE CUT TO CUSTOM LENGTH AND USE A GLUED TERMINAL FITTING INSTEAD OF THREADED. DATA FILTER CONNECTOR RF NUT RF GASKET SHIELD PLATE \IPPLE DETAIL RF NUT FILTER BACKPLATE DRYWALL AND PLYWOOD BACKING ALL —THREAD NIPPLE ALL —THREAD NIPPLE OPTION AND LENGTH MUST BE SPECIFIED TO FILTER MANUFACTURER. BETTER TOO LONG RATHER THAN TOO SHORT. \SIDE ICD ROOK E529 A504 STEEL PLATE E529 E529 FILTH PAST \UN3ES: * FIBER WAVEGUIDE: FIBERPLEX WGF-6 WITH WEB-6 & WET-18—A EXTENSION TUBES AND WCN-6 COUPLING NUT. * ANALOG PHONE FILTER: GENISCO GF58270-1 * ETHERNET FILTER: UNIVERSAL SHIELDING CORPORATION GIGAFOIL V3 USC-1061 * HVAC CONTROLS ANALOG DATA FILTER: GENISCO GF58270-10 * FIRE ALARM COMMUNICATION FILTER: GENISCO GF58270—XX OR APPROVED ALTERNATE. EXACT FIRE ALARM FILTER TO BE CHOSEN BASED ON THE NAC POWER SUPPLY SPECIFICATIONS TO PREVENT A GROUND FAULT CONDITION ON THE CIRCUIT. OUTSIDE ICD ROOfv ICD ROOM WALL (SECTIO\ VIEW) COVNUNICATIO\ ® 1/2" TO 3/4" PLYWOOD FOR FILTER MOUNTING, WAVEGUIDE SUPPORT, ETC. SIZE AND THICKNESS CAN VARY BASED ON WHAT IS MOUNTING ON OUTSIDE WALL. FIBER WAVEGUIDE * — INSTALL NEXT TO FILTERS. LEAVE ROOM FOR A 2ND ONE. KEEP CENTER 4" OR MORE FROM ADJACENT PENETRATIONS. PUT PIPE SLEEVE FEED—THROUGHS IN THIS PLATE. A INSIDE ICD ROOM • FIRST INTERIOR LAYER OF 5/8" DRYWALL. ® FILL GAPS AROUND SHIELD PLATE AND 1" DRYWALL LAYER WITH ACOUSTIC CAULK E529 E527 \ l� FILTERS: ® MOUNT SIDE BY SIDE AND THE FOLLOWING ARE ANTICIPATED: — XX DUAL ANALOG PHONE LINE * — XX ETHERNET (EACH NEEDS 120V PWR) * — XX HVAC CONTROLS ANALOG DATA * • — XX FIRE ALARM COMMUNICATION FILTER * SEE RESPECTIVE PLAN VIEW DRAWINGS FOR EXACT NUMBER OF FILTERS FOR EACH CLOSED ROOM. (NOT ® ALL CLOSED ROOM'S MAY HAVE THE SAME NUMBER OF FILTERS.) FILTER NIPPLES ARE TYPICALLY 1" ALL THREAD — SPECIFY REQUIRED LENGTH WHEN ORDERING AS DEFAULT LENGTH OF 3" WILL BE TOO SHORT. 4—PLEX RECEPTACLE — SOME FILTERS REQUIRE POWER — NEED POWER OUTLET ON OUTSIDE WALL NEAR THEM. • SEE DRAWING 1 E60 & 2E62 FOR FILTER POWER OUTLET LOCATIONS AND QUANTITIES OTHER \OYES: • WALL HEIGHT DRAWN IS MUCH SHORTER THAN ACTUAL WALL. • INSTALL FILTERS WHEN OUTSIDE DRYWALL AND PENETRATION PLATE HAVE BEEN INSTALLED (PRIOR TO INTERIOR DRYWALL OR FOILING). • GROUND PLATE SHOULD BE 48" WIDE TO ALLOW ROOM FOR MORE FILTERS AND PIPES/WAVEGUIDES. • GROUND PLATE TO BE MOUNTED HIGH ON WALL AS INTERIOR WALL SPACE BELOW 6' IS RESERVED FOR ALARM AND AMS BOXES. • HOLES IN EXTERIOR WALL/BACKING TO BE LARGE ENOUGH TO ALLOW REMOVAL OF PENETRATIONS. FOAM AROUND GAP IN PLYWOOD AFTER PENETRATIONS ARE INSTALLED. FILTER I\STALLATIO\ � SCALE: NONE 1E360, 1E410, 2E362, 2E412 E529 • GALVANIZED STEEL PENETRATION PLATE (WHEN INSTALLED) 1/8", 24"x48", McMASTER 8943K32 Li LLJ CL • FINAL INTERIOR WALL LAYER OF 5/8" DRYWALL WITH ALL SEAMS STAGGERED FROM FIRST LAYER. • CUT "WINDOW OPENING" FOR PENETRATION PLATE, EDGES JUST SHORT OF FIRST DRYWALL LAYER SO PLATE CAN BE REMOVED IF TRIM IS ADDED. • USE CONDUCTIVE SCREWS (STAINLESS, PHOSPHATE COATED, OR GALVANIZED STEEL) EVERY 6" AND MUST PENETRATE TO METAL STUD. ® USE ULTRA NT FOIL SHIELD (48" WIDE) WITH ADHESIVE ON WALLS, THEN CEILING AND FLOOR. J 0 LL_ LLJ 0 F- O Li J 0 OUTSIDE ICD ROOv4 ® 16 GA OR THICKER STEEL STUDS, 3-5/8" DEEP OR DEEPER. • SOUND INSULATION IN WALL CAVITY, ANCHORED SO IT DOESN'T GAP AT TOP. • 1/2" TO 3/4" PLYWOOD FOR FILTER MOUNTING, NIPPLE SUPPORTS, ETC. SIZE AND THICKNESS CAN VARY BASED ON WHAT IS MOUNTING ON OUTSIDE WALL. • SCREW AT LEAST EVERY 12" TO STUDS AS SOME FILTERS ARE HEAVY. SCREW TYPE NOT IMPORTANT OTHER THAN SHEAR STRENGTH AND ABILITY TO PENETRATE AND THREAD INTO STUD. STUD (SIDE VIEW) WALL A\D SHIELD ASSEV 3LY DETAIL 2 SCALE: NONE E527, E529 E529 ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 CE\ERAL \OTES: 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG—IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. EFERE\CE DRAWINGS: 9-08-1E360 9-08-2E362 9-08-1E410 9-08-2E412 9-08—E527 9-08— E528 9-08-1E60 TELEPHONE FIRST FLOOR TELEPHONE SECOND FLOOR LAN SYSTEMS — FIRST FLOOR LAN SYSTEMS — SECOND FLOOR SHIELDING AND TEMPEST ROOM REQUIREMENTS SHIELDING AND TEMPEST ROOM REQUIREMENTS 208Y/120V POWER PLAN �o\srucrio\ \orEs: INSTALL THE COMMUNICATION FILTERS SHOWN ON DRAWINGS 2E361, 2E362 AND 2E411, 2E412 AS SHOWN IN DETAIL 1. SEE ARCHITECTURAL DRAWINGS FOR ACCURATE WALL, CEILING, AND RF—SHEILINDING CONSTRUCTION DETAILS. P A7O c NFPA 12 201g City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 g SYM m 0 REVISION 9-08.1 TENANT IMPROVEMENT 34355 BY CASNE APPROVED WS DATE 07.24.18 SYM REVISION BY APPROVED DATE A 9-08.2 TENANT IMPROVEMENT 34355 CASNE CEC 11.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE CHECKED D. TOWNSEND ENGINEER CHECKED APPROVED APPROVED SUBTITLE SHIELDING & TEMPEST ROOM REQUIREMENTS TITLE ELECTRICAL 9-08.2 TENANT IMPROVEMENT BUILDING 09-08 CURRENT REVISION W5563002 SYMBOL A DATE 11.27.18 SHEET E529 JOB NO. W5563002 COMP NO. DEV. CENTER, WA DWG No. 09-08—E529 SWITCHED HOT LEGEND O r�) W I O 0 I m 0) 0 0 E 0 0 0 E 00 0, 0 m M a) co 0 0 O W -. C E O O 0 W ui SYM NORMAL t Neutral Wht AC Hot BIk POWER t 120 or 277 Red Yel LIGHTING ZONE 1 I I I I I I I I I 1 I I I I) 1 1 1 1 0 0 LMRC-212 DIMMING ROOM CONTROLLER 0 0 LMRJ SERIES PRE —TERMINATED CABLES OR CAT5e. FREE TOPOLOGY-- & SPLITTER ACCEPTABLE DT-300 OCCUPANCY SENSOR LMRJ—C8 COUPLER CAT5e (TYPICAL) *NOTE: CEILING MOUNT SENSOR HAS TWO RJ45 PORTS. CO\FETE\CE CO\TOL WR sw RJ45 (TYP) LIGHTING ZONE 2 RJ45 PORT (TYP) LMDM-101 Vio Gry _Yo _ 0-10V DIMMING CONTROL WIRING SWITCH OPERATION EACH DOOR HAS TWO WALL SWITCHES SWITCH 1: ZONE 1 ON/OFF & DIMMING SWITCH 2: ZONE 2 ON/OFF & DIMMING $w LMDM-101 LMDM-101 oov ucHri\c G DIAnAvI sw LMDM-101 $w 1 SCALE: NONE 1 E10 I E530 I 3-WAY HOTO SWITCH NEUTRAL 0 L---J FOR SINGLE SWITCH ROOMS, ELIMINATE FIRST SWITCH & TRAVELER SINGLE POLE/3-WAY SWITCH 0-10V DIM 0-10V DIM LED DIMMING DRIVER LED DIMMING DRIVER 3WAY LI\E VOLTAGE 0-10V Dlvly SCALE: NONE 1 E10, 2E12 E530 NOTE: ALL WIRING SHALL BE #12 THHN REVISION BY APPROVED DATE SYM REVISION BY SWITCHED HOT SWITCHED NEUTRAL 0-1OV DIMMING WIRES REGULAR HOT REGULAR NEUTRAL EMERGENCY HOT EMERGENCY NEUTRAL APPROVED DATE 9-08.1 TENANT IMPROVEMENT 34355 CASNE CEC 08.07.18 A 9-08.2 TENANT IMPROVEMENT W5563002 CASNE CEC 11.27.18 co 0 REGULAR NEUTRAL - 3 - 1 OR 2 - 4- 5 BLUE REGULAR HOT DIMMED NEUTRAL BALLAST/DRIVER VIOLET(+) GRAY(-) CAPOFF BLACK RED 1 1 I 1 1 ELCR-6A-010D EMERGENCY POWER • TEsr O swam • unun POWER 0 L VIOLET(+) EMERGENCY GRAY(-) DIMMED BALLAST/DRIVER HOT NEUTRAL REGULAR HOT DIMMED NEUTRAL BALLAST/DRIVER VIOLET(+) GRAY(-) J — — TO ADDITIONAL REGULAR LOADS VIOLET(+) GRAY(-) EMERGENCY LOAD VIOLET(+) GRAY(-) VIOLET(+) EMERGENCY GRAY(-) DIMMED BALLAST/DRIVER HOT NEUTRAL J RELAY: LSI INDUSTRIES #ELCR-6A-010D ENEKENCY LIGHTI\G BELAY TYPICAL WRI\G DETAIL TO ADDITIONAL EMERGENCY LOADS EMERGENCY SWITCH HOT EMERGENCY NEUTRAL SCALE: NONE 10 E5 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN C. LINDER CHECKED D. TOWNSEND '1Nt WiELR DATE 05.30.18 05.30.18 SUBTITLE GENERAL \OTES EFRE\CE DAW\GS 9-08-1E10 FIRST FLOOR LIGHTING PLAN 9-08-2E12 SECOND FLOOR LIGHTING PLAN CO\STRUCTIO\ \OTES PROVIDE AND INSTALL LIGHTING CONTROL SYSTEM COMPONENTS AND WIRING AS SHOWN. PROVIDE COMPLETE SETUP, PROGRAMMING, AND TESTING OF LIGHTING CONTROL SYSTEM. ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 00 PLIANCF NFPA77O- E APR 12 2019 City of Tukwila 6UILDING DIVISION RECfiVED CITY OF ` UKWILA FEB 2 5 2019 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-093 LIGHTING CONTROL WIRING CURRENT REVISION W5563002 SYMBOL A DATE 11.27.18 C. LINDER CHECKED APPROVED APPROVED 05.30.18 TITLE 9-08.2 TENANT IMPROVEMENT BUILDING 9-08 ELECTRICAL MASTER COL. (ALL) SHEET E530 JOB NO. W5563002 COMP NO. DEV. CENTER DWG NO. 9-08-E530 1 0 LEGEND \BABBAGE\Documents\ES\Projects\18\181-093 SH Boe 9-08.2 Tenant Improvement\_Drawings\09-008—E531.dwg SYM 3/4"C, 6#10 #10 GND 3/4"C, 3#10 #10 GND 3/4"C, 6#10 #10 GND REVISION 8,10,1 3/4"C 040 /Ii18 2,l6 110 3#10 #10 GND SERVE; OOM #1 E\ SCALE: 1/4" = 1' BY APPROVED p HP B17 HP 9 �4• 2,2 OA40 60A NF 3/4"C, 3#6, #10 GND /25,27,29 2C 15/ 13,15,17 2"C, 4#3/0, #6 GND 0 0 2B17 3/4"C, 6#10 #10 GND 3/4"C, 6#10 #10 GND 3/4"C, 6#12 #12 GND LARGED PLAN n 2E62 E53 DATE SYM REVISION BY APPROVED DATE co U) cii co 0 0 9-08.2 TENANT IMPROVMENT W5563002 CASNE EEK 11.27.18 DUAL ANALOG FILTER SCHEDULE REMARKS ROOM ANALOG DROPS DUAL FILTERS AREA #1 & WORK /DISCUSSION ROOM 29 18 INCLUDES 1 DROP AND (1) FILTER IN WORK ROOM AND 2 DROPS AND (1) FILTER IN COMPARTMENT #1 SERVER ROOM #1 1 2 SECURITY 4 2 AREA #2 2 4 SERVER ROOM #2 1 3 AREA #3 2 2 DUAL A\ALOG FILTER SCHEDULE 2 SCALE: N/A ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PROVED BY DEPT. DATE DRAWN 2E362 E531 DATE CHECKED SUBTITLE 20A, 125V, 1 PHASE 4-PLEX RECEPTACLE NEMA 5-20R, WALL MOUNT -0 30A, 125V, 1 POLE SINGLE RECEPTACLE, NEMA L5-30R 30A, 250V, 2 POLE SINGLE RECEPTACLE, 30 NEMA L6-30R 30A, 208V, 3 POLE SINGLE RECEPTACLE, 30 NEMA L21-30R THREE PHASE, 60A POWER FILTER, UNIVERSAL ® SHIELDING CORP. USC-50-60B4 POWER FILTER PLATE 208Y/120V, 30, 4W, PANELBOARD CE\EAL \OTES 1. UNLESS OTHERWISE NOTED ALL WIRING SHALL BE 3/4"C, 2#12 THHN/THWN. 2. CONDUCTORS SHOWN: #12AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS IN ACCORDANCE WITH THE LATEST NEC (USING TAPE), COLOR CODE AS FOLLOWS: AO (LEFT BUS IN PNL) BO (CENTER BUS IN PNL) CO (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND 208Y/120V BLACK RED BLUE WHITE GREEN 480Y/277V BROWN ORANGE YELLOW GRAY GREEN GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER DYNO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES AS DETAILED. 7. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. EFEE\CE DRAW\GS 09-008-2E62 208Y/120V POWER PLAN CO\STUCTO\ \OTES ISSUED FOR CONSTRUCTION NOVEMBER 27, 2018 ENLARGED PLAN DETAILS PROVIDE AND INSTALL CONDUIT, CONDUCTORS, BOXES, FITTINGS, SUPPORTS, AND ALL ANCILLARY HARDWARE. NO HOME -RUNS SHALL BE ALLOWED TO PASS 2. THROUGH CLOSED ROOMS. CONDUIT SHALL BE RE-ROUTED TO AREA BORDERED E./W. BY GRIDLINES A-C/11.5-12.6 AND N./S. BY GRIDLINES B.8-C/11.5-14.3. INSTALL NEW RUNS PRIOR TO CLOSED ROOM CONSTRUCTION SUCH THAT DOWNTIME FOR IN -USE RACEWAY IS MINIMIZED. PROVIDE AND INSTALL 480V, 60A, NEMA 12 DISCONNECT. 4. PROVIDE AND INSTALL ROOM RECEPTACLES. SEE LEGEND FOR DEVICE TYPE. PROVIDE AND INSTALL 208Y/120V, 30, 4W, NEMA 12, SURFACE MOUNT PANELBOARD AND 600V CONDUCTORS, CONDUIT, AND ANCILLARY HARDWARE BACK TO SOURCE VIA POWER FILTER. SEE SCH FOR PANEL SIZING AOMPLIANCF WI NFPA 770 - EC APR 1 2 2019 City of Tukwila aUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 5 2019 PERMIT CENTER CASNE .ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE COM JOB NO. 181-093 CURRENT REVISION W5563002 SYMBOL DATE 11.27.18 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER 9-08.2 TENANT IMPROVEMENT BUILDING 9-08.2 DEV. CENTER, WA SHEET E531 JOB NO. W5563002 COMP NO. DWG NO. 09-08.2-E531