Loading...
HomeMy WebLinkAboutPermit EL19-0209 - RED DOT CORPORATION - INJECTION MOLDING MACHINEThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL19-0209 RED DOT CORPORATION 495 ANDOVER PARK E THE ABOVE MENTIONED Page # DIGITAL Code RECORDS PERMIT FILE INCLUDES Exemption (DR) EXEMPTION LOG THE FOLLOWING REDACTED INFORMATION Brief E> lanatory Description Statute/Rule Personal Information — The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 14 DR2 Financial Information — RCW 42.56.230(4 5) account numbers, which are exempt from disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. 42.56.230(5) Personal Information — Driver's License. RCW Redactions contain information used to prove RCW DR3 — identity, age, residential address, social security 42.56.230 (7a 42.56.230 (7a & c) number or other personal information required to apply for a driver's license or identicard. & c) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW DR4 Attorney -Client Privilege — RCW 5.60.060(2)(a); RCW disclosure pursuant to RCW 5.60.060(2)(a), which protects attorney -client privileged 5.60.060(2)(a); RCW 42.56.070(1) communications, and RCW 42.56.070(1), which protects, under the PRA, information exempt or prohibited from disclosure under another statute. 42.56.070(1) RED DOT 495 ANDOVER PARK E ELI 9-0209 Parcel No: Address: �~^�xx � lF �"°"^� ~~�^� ��x xK�x��m�va Department mfCommunity Development 63UUSputhcenterBoulevard, Suite #1U8 Tukwila, Washington 9818Q Phone: 206-431'3670 Inspection Request Line: 206'438'9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 2623049094 Permit Number: EL19-0209 Project Name: RED DOT Issue Date: 3/25/2019 Permit Expires On: 9/21/2019 Owner: Name; Address: Contact Person: Name: Address: Contractor: Name: License No: Lender: Name: Address: HIGHLAND PARK PROPERTIES L 49SANDOVERPARK 8LVDE' TUKVV|U\VV4 98188 PETER[WOLNEV Phone: (253)872-5553 7056S220ST'KENT WA, 98032 SEA TA[ELECTRIC INC (ELE[TR|[AL) Phone; (253)872'5553 7056S ZIOTH5T,KENT,WA, 98O3Z- l91U SEATAE077RVV Expiration Date: 12/17/2019 ^"I DESCRIPTION O FWORK: ADDITION OF A NEW INJECTION MOLDING MACHINE PER ELECTRIC PLANS. Valuation ofsingle family: $0.00 Valuation o[mf/comm: $20,000.00 Type otWork: ADDITION Fees Collected: $612�89 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKvV|LA Sewer District: TUKVV|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 National Electrical Code: WA State Energy Code: VVACities Electrical Code: VVA[Z96-4G13: 2017 2017 Date: �� c" ,2S » / ' The granting of this permit does not presume to give authority to violate or cancel the provisions of anV other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree tothe conditions attached tuthis permit. Signatue: ��� Print Name: �^�ei�c�r �w'«*~lov~a� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection, PERMIT CONDITIONS: l: 'ELECTRICAL PERMIT [OND|T|ONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector ateach work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 NEC, and requirements for electrical installations, Chapter 296468VVACand the Washington Cities Electrical Code. 5: When any portion ofthe electrical installation is tobehidden from view bypermanent placement ofparts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation ofthe provisions cf the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change inthe scope ufwork described bythe electrical work permit shall require additional work permits, Where approved plans have been issued, revisions to the plans and additional review may be PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2nG)438'935O ZlOO ELECTRICAL FINAL 7003 RDUGH'|NELE[TRYCAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW, Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Per Project No. Date Application Accepted: 3 -1-1 Date Application Expires: (For office use only) No. e(,l1- UZoq a ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 495 ANDOVER PARK E King Co Assessor's Tax No.: Suite Number: New Tenant: Tenant Name: RED DOT PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication — Name: PETE MOLNER Address: 7056 S 220TH STREET City: KENT State: WA Zip: 98032 Phone: (253) 872-5553 Fax: (253) 872-4112 Email: pETE.MOLNER@SEATACELECTRIC.Ctlr' Floor: Yes ® ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: SEA-TAC ELECTRIC Address: 7056 S 220TH STREET City: KENT State: WA Zip: 98032 Phone: (253) 872-5553 Fax: (253) 872-4112 Contr Reg No.: SEATAEIO77Pd Exp Date: 12/19/2019 Tukwila Business License No.; 01-212 Valuation of Project (contractor's bid price): $ 20,000 Scope of Work (please provide detailed information): PER ELECTRICAL PLANS. ADDITION OF A NEW INJECTION MOLDING MACHINE Will service be altered? ❑ Yes No Adding more than 50 amps? 66 Yes ❑ No Type of Use: COMMERCIAL Type of work: ❑ New ❑✓ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: ® Puget Sound Energy ❑ Seattle City Light W:\Permit Center\Applications-Handouts \Permit Applicat Revised: January 2017 bh ns\PDP's\Electrical Permit Application Revised 1-1- 17.docx Page 1 of 2 JAN, RESIDENTIAL NEW RESIDENTIAL SERVICE El New single family dwellings $155.91 (including an attached garage) Garages, pools, spas and outbuildings $83.54 ea LJ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES El Service change or alteration $83.54 (no added/altered circuits) 111 Service change with added/altered circuits $83.54 number of added circuits $12.00 ea El Circuits added/altered without service change $55.69 (up to 5 circuits) o Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea El Meter/mast repair $69.62 O Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES • Temporary service (residential) $66.30 ▪ Temporary service (generator) $82.52 111 Manufactured/mobile home service $87.98 (excluding garage or outbuilding) E] Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 03/07/2019 Print Name: PETE MOLNER Day Telephone: (206) 459-4729 Mailing Address: 7056 S 220TH STREET - KENT, WA 98032 City State Zip W:\Permit Center \ Applications-riandoutsWermit Applicatinns \PDPsTlectrical Permit Application Revised I-1-17.docx Revised: January 2017 bh Page 2 of 2 DESCRIPTIONS PerrnitTRAK ACCOUNT QUANTITY PAID $612.89 EL19-0209 Address: 495 ANDOVER PARK E Apn: 262 049094 $612. 9 Credit Card Fee $17,85 Credit Card Fee R000.369.908.00.00 0.00 $17.85 ELECTRICAL $572.15 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $457.72 PLAN CHECK FEE R000,345,832.00.00 0.00 $114.43 TECHNOLOGY FEE $22.89 TECHNOLOGY FEE TOTAL, FEES PAID BY RECEIPT: R17108 R000.322.900,04.00 0.00 $22.89 $612.89 Date Paid: Thursday, March 07, 2019 Paid By: PETER MOLNER Pay Method: CREDIT CARD 055184 Printed: Thursday, March 07, 2019 2:36 PM 1 of 1 SYSTEMS CO TVKWILx ETRAKIT 6200 S0UTH[ENTEV 8LVD TUKwIL4, WA 98188 205'4]]'1870 CITY OF TUKWILx 8017340000802374464500 Date: 03/07/2019 02:30:19 PM CREDIT CARD SALE VISA [xRo NUMBER: ***+******5014 K TRAm AMOUNT: $612.89 APPROVAL [D: 055184 RECORD #: 000 cLsnx ID: jazzcI X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE 4o8v[ TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) ` Thank you! Merchant Copy CO TUKWILa ETRAKIT ouoo SOuTHccNTpx oLvD TUKWTLA, WA 98188 206'433-1870 CITY OF TUKWILA Date: 03/87/2019 02:36:19 PM [xsozT cxxo SALE VISA CARD NUMBER: ****+*****5014 K TRAN AMOUNT: $612.89 AppnOv4L [o: 055184 RECORD #: 080 CLERK IQ: jazzel Thank you! Customer Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. P ' h/IIT NI CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type tat` Inspection: Address: . �Date Called: Special Instru tions: q5 , Date Wanted: a.m p.m. Requester: Phone No: 77f o 77 Approved per applicable codes. Corrections required prior to approval. Inspector: Date: 7 Q REINSPECTI©FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ,... { Type of Inspection: , i Address: � 'Date Called: Special Instructions: Date Wanted: c q Requester: Phone No: Z G `21 C Approved per applicable codes. El Corrections required prior to approval. OMM ENTS: kit\ Tz) L-tAfe" inspector: REINSPECTI©. FEE REQUIRED. Prior to next inspection. fee m7' 7 ust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. I Date: 0 0PEMIT COORD CON C) PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0209 PROJECT NAME: RED DOT SITE ADDRESS: 495 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # DATE: 3/7/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: SY) AwG Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 3/12/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CO Approved ECTIONS: Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues DUE DATE:_ 4/09/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire El Ping 0 PW 0 Staff Initials: 12/18/2013 SEA TAC ELECTRIC INC Horne L',spaiiol Contact Page 1 of 3 Safety & Health Claims & Insurance Washington State Department of Labor & industries A-Z 1 ndex Help My Uszl Workplace Rights Trades-& Licensing SEA TAC ELECTRIC INC Owner or tradesperson Principals HARGREAVES, TOM, PRESIDENT JORDAN, TOM, VICE PRESIDENT BEAN, ERIC, SECRETARY BEAN, ERIC, TREASURER HARGREAVES, TOM, AGENT HARGREAVES, KATHERINE, SECRETARY (End: 12/10/2008) BURKS, ROY, VICE PRESIDENT (End: 12/15/1995) Doing business as SEA TAC ELECTRIC INC WA UBI No. 601 510 212 7056 S 220TH ST KENT, WA 98032 253-872-5553 KING County Business type Corporation Governing persons KATHERINE M HARGREAVES THOMAS R HARGREAVES; TOM JORDAN; ILicense Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SEATAEI077RW Effective — expiration 12/16/1993— 12/17/2019 Designated administrator Jordan, Thomas License type Master Electrician Bond DEVELOPERS SURETY & INDEM CO Bond account no. 798649C Active. Meets current requirements. License no. JORDAT*914LR $4,000 00 Received by L&I Effective date 12/03/2008 12/16/2008 Expiration date Help us improve • r• nrrnr,fllr1 fl# 1 # fl T Tfl CIT-• A m A 70 C1 A Ix 7_ SEA TAC ELECTRIC INC Until Canceled Page 2 of 3 Savings (in lieu of bond) $4,000.00 Received by L&I Effective date 12/16/1993 Release date Impaired date N/A N/A Savings account ID License Violations Infraction no. ECHAP01667 Issue date 11/03/2014 Violation city KENT Type of violation ELECTRICAL CITATION Description Failing to request an inspection within 3 business days after completion of the installation or 1 business day after energizing, whichever occurs first as referenced in WAC 296-46B-901. Infraction no. EW HAO00205 Issue date 04/23/2014 Violation city KENT Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. ELY0D00293 Issue date 12/24/2013 Violation city KENT Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-468-901. Satisfied RCWANAC 19.28.101 RCW Violation amount $250.00 Satisfied RCWANAC 19.28.101 RCW Violation amount $1,250.00 Satisfied RCWANAC 19.28.101 RCW Violation amount $2,000.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 536,103-01 Doing business as Help us improve rrnT—cn1c1n71lo.TTr".—OL"A'T'AUTm'7UAI/ P.QA\IJ— / PIG /7nic SEA TAC ELECTRIC INC SEA TAC ELECTRIC INC Estimated workers reported Quarter 4 of Year 2018 "Greater than 100 Workers" LW account contact T1 / LINDSEY BOOTH (360)902-5596 - Email: BOOO235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/24/2014 Inspection no. 316973916 Location 1225 W Bakerview Rd Bellingham, WA 98226 Inspection results date 06/1412013 Inspection no. 316803055 Location 1900 SE Sedgwick RD Port Orchard, WA 98366 No violations Violations Page 3 of 3 r Washington State Dept. of Labor Si Industries. Use of this site is subject to the laws of the state of Washington. Help us improve 1_A.1- •---- ._---L----.L-m-a.-11 .-_----nTmT—Cn1 C1 n'11'10_TTI",—OT7 A T' A T'Tn'7'7T)NZr 0-0 nII]— ? PICI'ln1n 3/7/2019 11:31 AM T: \DESICN PROJECTS - PENDING\RED DOT\CAD\E0.01.DWG NEW WIRING. HASH MARKS INDICATE NUMBER OF #12 AWG WIRE UNLESS NOTED OTHERWISE, NO HASH MARKS INDICATES TWO WIRES PLUS GROUND UNLESS NOTED OTHERWISE. LONG HASH MARKS DENOTES NEUTRAL. INDICATES GROUND WIRE. INDICATES ISOLATED GROUND WIRE, WHERE SHOWN. NEW WIRING RUN IN OR BELOW SLAB OR BELOW GRADE. EXISTING RACEWAY OR WIRING (IF HASH MARKS ARE SHOWN PULL NEW CONDUCTORS) RACEWAY STUB —OUT WITH BUSHING HOME RUN TO PANEL OR LOCATION NOTED CIRCUIT CONTINUATION OO /1-OO JUNCTION BOX, CEILING/WALL Ps PULL BOX NH HANDHOLE ----P/T/c---- P/T/c C 0 UNDERGROUND UTILITY SERVICE — POWER, TELEPHONE & CABLE AS INDICATED OVERHEAD UTILITY SERVICE — POWER, TELEPHONE & CABLE AS INDICATED POWER POLE/GUY G c' GROUND WIRE Cfl O•- EP z' CD M !CRAP IRREVERSIBLE COMPRESSION TYPE CONNECTION CADWELD TYPE GROUND CONNECTION GROUND TEST WELL GROUND ROD DUPLEX RECEPTACLE 120V DOUBLE DUPLEX RECEPTACLE 120V DUPLEX / QUAD RECEPTACLE — EMERGENCY POWER DUPLEX RECEPTACLE — GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLE — GROUND FAULT CIRCUIT INTERRUPTER TYPE, STANDBY POWER DOUBLE DUPLEX RECEPTACLE — GROUND FAULT CIRCUIT INTERRUPTER TYPE DEDICATED DUPLEX / QUAD RECEPTACLE DUPLEX RECEPTACLE — SAFETY TYPE DUPLEX RECEPTACLE — ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GFI DUPLEX RECEPTACLE — ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ON PLAN — ATTACH TO DROP CORD FROM CEILING SINGLE RECEPTACLE 120V TRIPLE RECEPTACLE SPLIT SWITCHED DUPLEX RECEPTACLE FLUSH FLOOR BOX WITH DEVICE AS INDICATED FLUSH MOUNTED CEILING RECEPTACLE PEDESTAL TYPE FLOOR BOX WITH DEVICES AS SHOWN FLUSH FLOOR POKE THROUGH — DEVICES AS INDICATED SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED DRYER RECEPTACLE DISCONNECT SWITCH FUSED DISCONNECT MOTOR STARTER COMBINATION MOTOR STARTER, DISCONNECT MOTOR CONNECTION MOTOR, THREE PHASE EQUIPMENT CONNECTION CLOCK HANGER AND OUTLET ON CRITICAL BRANCH CIRCUIT CONTACTOR MOTOR RATED SWITCH GENERATOR REMOTE ANNUNCIATOR PANEL PANEL — 208/120 VOLT SYSTEM, +6' TO TOP U.N.O. PANEL — 480 VOLT SYSTEM, +6' TO TOP U.N.O. O MAGNETIC DOOR HOLD —OPEN. INTERNAL TO CLOSER HARDWARE WHERE SHOWN AT HINGE. FIRE ALARM MANUAL STATION +48" SMOKE DETECTOR "D" SUBSCRIPT INDICATES DUCT DETECTOR "H" SUBSCRIPT INDICATES HEAT DETECTOR "R" SUBSCRIPT INDICATES 120V RESIDENCE DEVICE WITH AUDIBLE TONE ALARM, BATTERY BACK—UP COMBINATION SPEAKERS/STROBE, WALL MOUNTED AT +80" UNLESS NOTED OTHERWISE "R" SUBSCRIPT INDICATES AUDIBLE ALARM FOR RESIDENCE UNIT WIRED TO ACCOMODATE UPGRADE TO ALARM/STROBE. I>0 COMBINATION HORN/STROBE, CEILING MOUNTED FIRE ALARM STROBE ONLY, WALL MOUNTED AT +80" >0 FIRE ALARM STROBE ONLY, CEILING MOUNTED CI FIRE ALARM REMOTE INDICATOR LIGHT Cfp FIRE ALARM BELL/CHIME FACP W R FIRE ALARM CONTROL PANEL TELEPHONE OUTLET: "W" INDICATES WALL PHONE AT +54" D DATA OUTLET -0-0- DSI 0-1 COMBINATION TELE/DATA OUTLET COMBINATION FIRE/SMOKE DAMPER CONNECTION MOTORIZED DAMPER — 120V MAGNETIC CONTACTS FOR WINDOW OR DOOR MONITORING PEDESTAL TYPE FLOOR BOX WITH DEVICE TYPE AS SHOWN CABLE RING ROUTE ELECTRIC CLOCK TV COAXIAL CONNECTION CEILING MOUNTED SPEAKER WALL MOUNTED SPEAKER MICROPHONE TELEPHONE RISER FLOOR CORE FOR VOICE/DATA ONLY CARD READER AUDIBLE DOOR ALARM VOLUME CONTROL AT +54" EMERGENCY POWER OFF BUTTON XX EM 0 0-1 EM a OS 3 D DF os TC 0 FLUORESCENT FIXTURE, TYPE AS INDICATED ON PLAN "XX" INDICATES FIXTURE TYPE, "EM" INDICATES EMERGENCY OPERATION FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE FIXTURE CEILING MOUNTED FIXTURE WALL MOUNTED FULL —SHADED FIXTURES SHALL BE CONNECTED TO EMERGENCY POWER SERVICE PANEL, "EM" INDICATES EMERGENCY OPERATION POLE MOUNTED EXTERIOR LIGHT FIXTURE BATTERY PACK EMERGENCY LIGHTING UNIT BATTERY POWERED EXIT SIGN — ARROWS AS INDICATED, SHADING INDICATES SIDE(S) ILLUMINATED. BATTERY POWERED EXIT SIGN WITH INTEGRAL EMERGENCY LIGHTS, ARROWS AS INDICATED SINGLE POLE SWITCH (LETTER INDICATES SWITCH LEG) OCCUPANCY SENSOR WALL SWITCH 3 WAY SWITCH INCANDESCENT DIMMER/SWITCH FLUORESCENT DIMMER/SWITCH DAYLIGHT SENSOR, # INDICATES CONTROLLED CIRCUIT DESIGNATION CEILING OCCUPANCY SENSOR PHOTO —CELL SWITCH MOUNTED UNDER SOFFIT, ORIENT NORTH TIMECLOCK I FIXTURE PENDANT MOUNTED WALL SCONCE SURFACE MOUNT 2X4 � I TRACK LIGHTING A TRANSFER SWITCH CIRCUIT BREAKER -{� »}- DRAW OUT CIRCUIT BREAKER FEEDER DESIGNATION ----FIFTH FUSED SWITCH GROUND PANEL (-` -- \ /// XXX xx- x x x PANEL GROUND FAULT CIRCUIT BREAKER TRANSFORMER CABLE TO BUS CONNECTION AVAILABLE SHORT CIRCUIT CURRENT METER FLAG NOTE REVISION SYMBOL EXISTING EQUIPMENT OR DEVICE REMOVE EXISTING ELECTRICAL EQUIPMENT EQUIPMENT IDENTIFIER TYPICAL ROOM DETAIL REFERENCES: XX — INDICATES DETAIL NUMBER M — INDICATES THAT DETAIL IS MIRROR IMAGE OF REFERENCED LOCATION EY.Y — INDICATES SHEET WHERE DETAIL IS FOUND — DIRECTION OF ARROW INDICATES PLAN ORIENTATION IN RELATION TO DETAIL PROPERTY LINE FENCING CABLE TRAY CQ INDICATES COMBINATION POWER/TELE/DATA POKE—THRU FLUSH 0 FURNITURE FEED JUNTION BOX. AFF A, AMP ATS AWG (BTS) CB CKT DED DW (E) EPO EWC FA FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FI FILM ILLUMINATOR G, GND GROUND- GD GARBAGE DISPOS'\L GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER HT HEIGHT HWT HOT WATER TANK IGN IGNITION IH INSTA HOT J—BOX JUNCTION BOX MW MICROWAVE — COORDINATE MOUNTING HEIGHT N NEUTRAL P POLE PNL PANEL PROVIDE FURNISH AND INSTALL (R) RELOCATED (INDICATES EXISTING EQUIPMENT TO BE RE —INSTALLED AS SHOWN) RO RACEWAY ONLY REC RECEPTACLE REF REFRIGERATOR S SAFETY TYPE SWBD SWITCHBOARD TYP TYPICAL UC UNDERCABINET UNO UNLESS NOTED OTHERWISE ✓ VOLT W WIRE OR WATT PHASE W/0 WITHOUT WP WEATHERPROOF AC INDICATES ABOVE COUNTER MOUNTING AT +4" ABOVE BACKSPLASH OR +6" ABOVE COUNTERS WITHOUT BACKSPLASH ABOVE FINISHED FLOOR AMPERE AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAGE BASE TRANSFER STATION CIRCUIT BREAKER CIRCUIT DEDICATED DISHWASHER EXISTING EMERGENCY POWER OFF ELECTRIC WATER COOLER FIRE ALARM NOTE REGARDING DRAWINGS: THESE DRAWINGS ARE PROVIDED FOR YOUR USE RELATING EXCLUSIVELY TO THE PROJECT CONTAINED HEREIN. SEA—TAC ELECTRIC, INC. PROVIDES THESE DRAWINGS WITH THE FOLLOWING STIPULATIONS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF SEA—TAC ELECTRIC, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN CONSENT OF SEA—TAC ELECTRIC, INC. THE DESIGNS CONTAINED HEREIN ARE PROTECTED BY THE RULES AND REGULATIONS OF U.S. COPYRIGHT LAWS. THESE DRAWINGS AND DOCUMENTS WERE COPIED FROM COMPUTER DATA CREATED AS A STEP IN THE PRODUCTION OF PHYSICAL DATA FOR THIS PROJECT. THERE MAY BE DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE COMPUTER DATA. WHERE SUCH DISCREPANCIES EXIST, ONLY THE PHYSICAL DOCUMENTS AND DRAWINGS CAN BE RELIED ON TO REFLECT THE WORK OF SEA—TAC ELECTRIC, INC., WHO MAKES NO GUARANTEES OR WARRANTIES REGARDING THESE DOCUMENTS OR THE DATA THEREIN. IN ACCEPTING THESE DOCUMENTS, YOU ASSUME ALL LIABILITY FOR THE ACCURACY, UTILITY, OR SUITABILITY FOR ANY PURPOSE FOR ANY DATA THESE DRAWINGS CONTAIN. COPYRIGHT© 2019 GENERAL NOTES: NOTE:"CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", "PROVIIDE", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE: THE INTENT OF THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PERMITS AND FEES: THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. WARRANTY: THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANTY ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. CODES: PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE, STATES, CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE EC SHALL SATISY CODE, AHJ, DRAWINGS, AND SPECIFICATIONS AS A MININUM STANDARD WITHOUT ANY EXTRA COST. STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. COPYRIGHT© 2019 REVISIONS No changes shall be made to the scoO of work without prior approval of the Tukwila Building Division. NOTE: Revisions wilt require a new plan submittal and may include additional plan review: FILE COPY . - 14 PlanPermlt review NoapprovalE2Is subject to errors ano omissions. Approval of construction documents does not auth"nze the violation of any adopted code or ordinance. Receipt of approved Fiala Copy and conditions is acknowledged: By: Date: / City of TuKwlla BUILDING DIVISION REVIEWS FOR — COMPLI Ewit�I�n NFPA 0-NEC R2220 4 S City of Tukwila BUILDING DIVISION E0.01 E0.02 — ELECTRICAL NOTES E2.01 — NORTH POWER PLAN E5.01 — ONE —LINE RISER DIAGRAM SEPARATE PERMIT REQUIRED FOR: (.Y Mechanical ❑ Electrical ER/ Plumbing LGas Piping City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 072019 PERMIT CENTER — SYMBOLS & ABBREVIATIONS (.5 z 0 LEI J W PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 Z O H ct o OZ ao cto o m Nft- 0 ct o THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY RED DOT CORPORATION AS A DESIGN BUILD CONCEPT. THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF SEA-TAC ELECTRIC, INC. FOR INFORMATION CONTACT: COREY MCKINNON - DIRECTOR OF DESIGN @ (253) 872-5553 REV # DATE DRAWN CM CHECKED CM DATE 03/07/2019 SYMBOLS & ABBREVIATIONS EOO1 PLAN SPECIFIC GENERAL NOTES: GENERAL ELECTRICAL NOTES: RACEWAYS TADESIGN PROJECTS - PENDING\RED DOT\CAD\E0.02.DWG 3/7/2019 11:31 AM it 1. THE FOLLOWING GENERAL NOTES APPLY TO ALL DRAWINGS ITEMS NOTED AS "TYPICAL" ON ANY DRAWING REFERS TO ALL DRAWINGS. 2. PROVIDE NYLON PULL STRING IN ALL EMPTY RACEWAYS. 3. NO STRUCTURAL MEMBERS SHALL BE CUT OR ALTERED WITHOUT PRIOR APPROVAL OF THE ARCHITECT AND STRUCTURAL ENGINEER. 4. LOCATIONS OF ALL MOUNTED DEVICES ARE SHOWN SCHEMATICALLY. COORDINATE WITH THE ARCHITECTURAL DRAWINGS, ELEVATIONS AND CASEWORK SUPPLIERS SHOP DRAWINGS FOR EXACT LOCATION OF DEVICES PRIOR TO ROUGH IN. 5. RACEWAYS IN FINISHED SPACES SHALL BE CONCEALED. 6. PROVIDE 2" EMT SLEEVES FOR LOW VOLTAGE WIRING RUNNING THROUGH NON -RATED WALLS, FLOORS AND CEILINGS. 7. PROVIDE STI "EZ-PATH" ASSEMBLIES AT EACH LOCATION WHERE LOW VOLTAGE WIRING PENETRATES A RATED WALL OR CEILING. ASSUME 50 ARE TO BE PROVIDED. 8. SEAL PENETRATIONS IN RATED FLOORS AND CEILINGS WITH A UL APPROVED FIRE STOP SYSTEM. 9. PROVIDE A COMPLETE DESIGN -BUILD PATHWAY SYSTEM FOR ALL POWER & SPECIAL SYSTEMS WIRING, SEE SPECIFICATIONS. QUANTITY AND SIZE OF RACEWAYS SHOWN ON POWER & SPECIAL SYSTEMS PLANS ARE THE MINIMUM TO BE PROVIDED. CONTRACTOR SHALL PROVIDE ALL RACEWAYS AS REQUIRED. 10. LOW VOLTAGE WIRING NOT RUN IN A METALLIC RACEWAY SHALL BE PLENUM RATED. 11. EQUIPMENT, LUMINAIRES, RACEWAYS, DEVICES, ETC. SHALL BE UL LISTED. 12. MOUNT DEVICES ABOVE COUNTERS 6" ABOVE BACKSPLASH UNLESS NOTED OTHERWISE, 13. WHERE A CONFLICT EXISTS THE MOST EXPENSIVE OPTION SHALL GOVERN. 14. PROVIDE RACEWAYS AND WIRING REQUIRED TO INSTALL ELECTRONIC DOOR HARDWARE. REFER TO DOOR HARDWARE SPECIFICATION, SCHEDULES AND DIAGRAMS. EQUIPMENT CONNECTIONS 1. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER SHOP DRAWINGS PRIOR TO ROUGH -IN. 2. INSTALL AND WIRE EQUIPMENT PER MANUFACTURER SHOP DRAWING. 3. PROVIDE ALL RACEWAYS, WIRING ONLY AS SHOWN ON MANUFACTURER SHOP DRAWINGS. 4. PROVIDE HARDWIRED CONNECTION, RECEPTACLE OR FUSED DISCONNECT SWITCH ON MANUFACTURER SHOP DRAWINGS. POWER & SPECIAL SYSTEMS PLANS THE FOLLOWING GENERAL NOTES APPLY TO ALL POWER & SPECIAL SYSTEMS PLANS. 1. CIRCUIT ALL FIRE/SMOKE DAMPERS AND SMOKE DAMPERS FROM NEAREST 120V EMERGENCY PANEL WITH i" EMT CONDUIT, (3) #12 AWG. RECORD CIRCUITING ON AS -BUILT DRAWINGS. REFER TO MECHANICAL DRAWINGS FOR DAMPER LOCATIONS. 2. PRIOR TO ORDERING EQUIPMENT OR ROUGH -IN, COORDINATE WITH THE MECHANICAL CONTRACTOR TO ESTABLISH THE ACTUAL LOAD AND OVERCURRENT PROTECTION REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. 3. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR EQUIPMENT RATINGS AND FEEDER SIZES. 4. PROVIDE DISCONNECT SWITCH OR COMBINATION STARTER FOR EACH PIECE OF EQUIPMENT AS SHOWN ON MECHANICAL EQUIPMENT CONNECTION SCHEDULE. 5. PRIOR TO ROUGH -IN OF ALL EQUIPMENT SPECIFIED BY OTHER DIVISIONS COORDINATE WITH THE EQUIPMENT MANUFACTURER TO ESTABLISH ALL REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. 6. EXTERIOR RECEPTACLES SHALL BE WP/GFCI. 7. HOMERUNS OVER 100' SHALL BE #10 AWG MINIMUM. 8. POWER AND SPECIAL SYSTEMS TO SHARE A COMMON FLOOR BOX. 9. FEEDER ROUTING SHOWN IS APPROXIMATE. COORDINATE WITH MECHANICAL SYSTEMS AND BUILDING STRUCTURE. PROVIDE OFFSETS AS REQUIRED. 10. RECEPTACLES WITHIN 6 FEET OF A SINK SHALL BE A GFCI TYPE. 11. MINIMUM RACEWAY SIZE SHALL BE i" FOR ALL OTHER SYSTEMS. 12. POWER AND SPECIAL SYSTEMS WIRING SHALL BE RUN UTILIZING OPEN WIRING METHOD ABOVE ACCESSIBLE CEILINGS. PROVIDE METALLIC RACEWAYS FOR WIRING INSTALLED IN WALLS, ABOVE INACCESSIBLE CEILING, WHERE EXPOSED OR WHERE SUBJECT TO PHYSICAL DAMAGE. RACEWAY FILL SHALL NOT EXCEED 40%. 13. PROVIDE FIRE ALARM CONNECTION TO FIRE SPRINKLER TAMPER, FLOW, AND PRESSURE SWITCHES. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS. 14. PROVIDE i" A-C FIRE RETARDANT PLYWOOD ON SERVER ROOM WALLS FORE TELE/DATA BACKBOARD. MOUNT 8' DIMENSION VERTICAL. 15. STAPLES SHALL NOT BE USED TO SECURE LOW VOLTAGE CABLING. 16. CABLING NOT RUN IN A METALLIC RACEWAY SHALL BE PLENUM RATED. ONE LINE DIAGRAM 1. FEEDERS ARE ALUMINUM WITH THHN/THWN INSULATION. 2. PROVIDE PULL BOXES AS REQUIRED BY THE NEC. 3. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELS AND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN. 4. THE ONE -LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THE ACTUAL ROUTING OF RACEWAYS. 5. FOR TWO SECTION PANELS PROVIDE FULL SIZE FEEDER CONNECTIONS FROM SECTION 1 TO SECTION 2. 6. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL AND SWITCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARE CIRCUIT BREAKERS. BRANCH CIRCUIT WIRING THE FOLLOWING GENERAL NOTES APPLY TO ALL DRAWINGS 1. IN GENERAL ONLY CIRCUIT NUMBERS HAVE BEEN SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED RACEWAYS AND WIRING. 2. SHOW RACEWAYS AND WIRING ON AS -BUILT DRAWINGS. 3. GENERAL: 3.1. MINIMUM RACEWAY SIZE SHALL BE i" EMT 3.2. NO MORE THAN 6 #12 AWG CONDUCTORS SHALL BE INSTALLED IN A RACEWAY, 3.3. HOMERUNS GREATER THAN 100 FEET TO THE FIRST DEVICE SHALL BE #10 AWG. 3.4. LIGHTING, POWER AND MECHANICAL EQUIPMENT CONDUCTORS SHALL NOT BE COMBINED IN THE SAME RACEWAY. 3.5. PROVIDE A GROUND CONDUCTOR IN ALL RACEWAYS. 3.6. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULTI -POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 4. LIGHTING: 4.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUITING AND SWITCHING DUTY AS SHOWN ON THE DRAWINGS. 4.2. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULTI -POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 5. POWER: 5.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUITING SHOWN. 5.2. FOR OTHER THAN 15 OR 20 AMP SINGLE PHASE RECEPTACLE BRANCH CIRCUITS PROVIDE A DEDICATED HOMERUN TO THE PANEL. 5.3. FOR 30 AMP BRANCH CIRCUITS PROVIDE #10 AWG CONDUCTORS. FOR 40 AMP AND LARGER BRANCH CIRCUITS PROVIDE RACEWAYS AND WIRING AS SHOWN ON THE DRAWINGS. 5.4. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULTI -POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 6. MECHANICAL EQUIPMENT: PROVIDE RACEWAYS AND WIRING AS SHOWN ON THE MECHANICAL EQUIPMENT CONNECTION SCHEDULE. 1. EC SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND BE RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL THE FULL SCOPE OF WORK. IN ADDITION, THE EC SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. 2. EC SHALL COORDINATE WITH THE GC TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 3. EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE MOUNTED TO WALLS, COORDINATE WITH OWNER OR OWNER'S REPRESENTATIVE FOR APPROVAL AND SEE SPECS FOR FURTHER INFORMATION. 4. VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS, OWNER OR OWNER'S REPRESENTATIVE AND EXISTING SITE CONDITIONS. VERIFY FINAL DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE TRANSITIONS, ETC. 5. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM(S). FOLLOW DRAWINGS IN LAYING OUT WORK AND COORD. WITH OTHER TRADES TO VERIFY SPACE CONDITIONS AND CLEARANCES. MAINTAIN HEADROOM AND SPACE CONDITION. MAKE APPROPRIATE ADJUSTMENTS AT OWNER OR OWNER'S CONTRACTOR'S DIRECTION. 6. COORDINATE WITH OTHER TRADES FOR ANY NEEDED LOW VOLTAGE CONTROL WIRING AND DEVICES THAT IS NEEDED BUT MAY NOT BE SHOWN IN THESE DRAWINGS. 7. TEMPORARY POWER: REUSE EXISTING PANEL (IF IN GOOD CONDITION) AND SERVICE FOR TEMPORARY CONSTRUCTION POWER. ALL RECEPTACLES TO BE USED DURING CONSTRUCTION SHALL BE GFI PROTECTED. 8. ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUITS LOADS BETWEEN THE PHASES OF THE SYSTEM TO WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANELBOARD. 9. THE EC SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) SHUTDOWNS WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL SHUTDOWNS SHALL OCCUR BETWEEN 11:OOPM AND 5:OOAM. GENERAL NOTE:"CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", "PROVIIDE", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE THE INTENT OF THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANTY ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. CODES PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE, STATES, CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE EC SHALL SATISY CODE, AHJ, DRAWINGS, AND SPECIFICATIONS AS A MININUM STANDARD WITHOUT ANY EXTRA COST. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. BASIC MATERIALS AND METHODS MATERIALS: PROVIDE ALL NEW MATERIAL AND EQUIPMENT UNLESS NOTED OTHERWISE. ALL EQUIPMENT SHALL BE UL APPROVED, LABELED, AND LISTED OR OTHER APPROVED TESTING ORGANIZATION WHICH HAS ACCEPTANCE BY THE AUTHORITIES HAVING JURISDICTION FOR THE PURPOSE FOR WHICH THEY ARE USED. IN ADDITION, MEETING ALL REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS. NO SUBSTITUTION OF MATERIALS SPECIFIED WILL BE ALLOWED UNLESS NOTED OTHERWISE. ALL ITEMS ARE NEW UNLESS OTHERWISE NOTED. CUTTING AND FITTING: PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF THE WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WITHOUT THE CONSENT OF THE ARCHITECT, CONSTRUCTION MANAGER, GC, AND/OR OWNER. PROPERLY FILL, SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES AND HOLES IN SLABS, WALLS, AND CASEWORK. PROVIDE CODE APPROVED WIRING METHODS .FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT CONDUIT WITH COPPER CONDUCTORS OR MC CABLE (PROVIDED IT IS CONCEALED FROM VIEW AND NOT EXPOSED). ALL ABOVE GROUND CONDUITS SHALL BE EMT OR RIGID, MINIMUM 1/2" IN SIZE (UON). CONDUITS SHALL BE SIZED PER CODE AND AS NEEDED TO INSTALL CONDUCTORS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. PVC CONDUITS ARE NOT ALLOWED ABOVE SLAB UNLESS CODE AND AHJ APPROVED/LISTED FOR THAT USE. CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE CONCEALED AND BE RIGID STEEL CONDUIT WITH WEATHER TIGHT, CORRISION-RESISTANT FITTINGS (OR PVC WHERE LISTED FOR EXTERIOR -SUNLIGHT USE). CONDUIT SHALL NOT BE RUN EXPOSED WITHOUT SPECIFIC PERMISSION FROM THE CONSTRUCTION MANAGER. WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON PULL STRINGS END TO END WITH A LABEL ON BOTH ENDS STATING USE AND LOCATION OF OTHER STUB (E.G. DATA -FRONT POS). PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T&B FLAME SAFE OR OTHER METHOD APPROVED THE ARCHITECT AND AHJ. CONDUIT RUNS CONCEALED IN CONCRETE OR UNDERGROUND SHALL BE 3/4" MINIMUM, UNLESS OTHERWISE NOTED W/RIGID STEEL ELBOWS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. IF CONDUIT RACEWAYS CANNOT BE RECESSED IN WALLS DUE TO CONSTRUCTION OR EXISTING CONDITIONS, PROVIDE A STEEL SURFACE MOUNTED RACEWAY SYSTEM (WIREMOLD, HUBBEL OR APPROVED EQUAL) WITH ALL COMPATIBLE DEVICES. THIS TYPE OF SYSTEM IS ONLY ALLOWED WHERE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE INCLUDING LAYOUT. CONFIRM COLOR AND ANY CUSTOM FINISHES WITH OWNER OR OWNER'S REPRESENTATIVE. CONDUCTORS AND TERMINATIONS CONDUCTORS: SHALL BE ALUMINUM, INSULATED FOR 600V, TYPE THWN/THHN, NUMBER 12 AWG MIMIMUM UNO. MOTORS AND OTHER WIRING: THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NEEDED CONDUIT, WIRING, CONNECTIONS, AND SAFETY SWITCHES FOR ALL MOTORS, AND EQUIPMENT, EVEN IF THE MOTORS AND EQUIPMENT ARE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. MAY BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL. ALL ELECTRICAL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WITH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT PRIOR TO ROUGH -IN. GROUNDING ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITED T0, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES AND OTHERS DEFINED BY CODE, SHALL BE PROPERLY GROUNDED. METALLIC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS TO PROVIDE GROUND CONTINUITY. SWITCHES AND RECEPTACLES SWITCHES: GRADE OR APPROVED EQUAL WITH DURABLE COVERPLATES. COORDINATE WITH OWNER OR OWNER'S REPRESENTATIVE DM FOR COVERPLATE TYPE (E.G. STAINLESS STEEL) AND FOR COLOR OF SWITCH AND PLATE. RECEPTACLES: GRADE OR APPROVED EQUAL WITH DURABLE COVERPLATES. COORDINATE WITH OWNER OR OWNER'S REPRESENTATIVE DM FOR FOR COVERPLATE TYPE (E.G. STAINLESS STEEL) AND FOR COLOR OF RECEPTACLE AND PLATE. INSTALL RECEPTACLES PLUMB, LEVEL, AND SECURE TO J-BOX. PROVIDE GFCI TYPE WHERE INDICATED AND WHERE REQUIRED BY CODE AND AHJ. GFCI RECEPTACLES SHALL BE CLASS A RATED FOR PERSONNEL PROTECTION.ALL RECEPTACLES ARE TO BE MOUNTED 18" ABOVE FINISHED FLOOR TO CENTER OF DEVICE UNLESS NOTED OTHERWISE. OCCUPANCY SENSORS: SENSORSWITCH WSD SERIES FOR SINGLE OCCUPANT RESTROOMS AND CLOSETS AND SENSORSWITCH CONTRACTOR CHOSEN/OWNER APPROVED (PIR AND ULTRASONIC SOUND ACTIVATED) FOR PARTITIONED RESTROOMS. LOW VOLTAGE ALL LOW VOLTAGE WORK SHALL COMPLY, BE PERMITTED AND INSPECTED PER STATE (AND LAHJ) REQUIREMENTS. ALL LOW VOLTAGE WORK SHALL BE INSTALLED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH THE STATE AND LAHJ REQUIREMENTS. ALL LOW VOLTAGE CABLING INSTALLED UNDERGROUND SHALL BE ROUTED IN A CONDUIT RACEWAY AND CABLING/CONDUCTORS SHALL BE LISTED FOR USE IN WET LOCATIONS, FOR LOW VOLTAGE APPLICATION AND PER LAHJ. ALL LOW VOLTAGE CABLING ROUTED INDOORS SHALL BE ROUTED CONCEALED IN WALLS/CEILINGS IN A CONDUIT RACEWAY (UNLESS OWNER AND LAHJ AUTHORIZE IT TO BE ROUTED EXPOSED THROUGH WALL/CEILING). IF APPROVED BY OWNER & LAHJ TO BE ROUTED EXPOSED, CABLING SHALL BE PROPERLY FASTENED/SUPPORTED PER CODE, LAHJ, AND INDUSTRY STANDARDS. CABLING NOT ROUTED IN CONDUIT SHALL BE PLENUM RATED WHERE REQUIRED BY CODE OR LAHJ (CONFIRM WHETHER CEILING SPACE IS BEING USED AS AN AIR PLENUM.) ALL LOW VOLTAGE CABLING OUTDOORS (E.G. ON ROOF) SHALL BE ROUTED IN CONDUIT PER CODE AND LAHJ REQUIREMENTS UNLESS SPECIFICALLY LISTED AND LABELED FOR EXTERIOR USE. PANELBOARDS PANELBOARDS SHALL HAVE PLUG-IN OR BOLT ON BREAKERS AND MAIN LUGS ONLY OR MAIN BREAKERS AS NEEDED OR REQUIRED. PANELBOARDS SHALL BE CONSTRUCTED WITH ALUMINUM BUS AND BE ENCLOSED IN NEMA 1 HOUSING (OR AS REQ'D BY CODE). ENCLOSURE(S) SHALL BE COMPLETE WITH A HINGED DOOR, CYLINDER LOCK, AND A NEATLY TYPED CIRCUIT BREAKER DIRECTORY UNDER PLASTIC COVER IN EACH PANEL. ALL MULTIPLE POLE BREAKERS (AND OTHER BREAKERS REQ'D BY CODE) SHALL HAVE A COMMON TRIP HANDLE. FUSED SWITCHES FUSED SWITCHES: HEAVY DUTY TYPE, HORSE POWER RATED WITH INTERLOCKING COVER. NEMA 1 TYPICAL. OUTDOORS AND WET LOCATION SWITCHES SHALL BE RAINTIGHT TYPE NEMA 3R. ALL SWITCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600A OR LESS SHALL BE UL CLASS RK1 DUAL -ELEMENT, TIME DELAY, CURRENT LIMITING FUSES. FUSES IN CIRCUITS RATED AT 601A OR LARGER SHALL BE UL CLASS L TIME -DELAY, CURRENT LIMITING SWITCHES. MOUNTING MOUNT DISCONNECTS TO STRUCTURE, INDEPENDENT OF THE MECHANICAL UNIT HOUSING OR WITH INDEPENDENT UNISTRUT SUPPORT. DISCONNECTS MOUNTED TO UNITS ARE ONLY ALLOWED WHERE ACCEPTED BY THE LOCAL CODE AUTHORITY AND LOCATED SO AS TO NOT BLOCK ACCESS OR LABELS OF UNIT. NAMEPLATES PROVIDE PHENOLIC NAMEPLATES ON ELECTRICAL DEVICES SUCH AS DISCONNECTS AND PANELS WITH THEIR DESIGNATION (E.G. "PANEL A"). PROVIDE DIRECTORY FOR PANELS AND LABEL ALL BREAKERS. IF A TRANSFORMER IS INSTALLED, PROVIDE NAMEPLATE ON TRANSFORMER AS FOLLOWS: "HOT SURFACE, DO NOT PLACE ANY ITEMS ON TOP OR ON SIDES OF TRANSFORMER". REVIEWEQp FOPL OOMPLIANCE WITH I�IFPA 770 - @C WAR 2 2 2019 City of Tukwila pUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 0 7 2019 PERMIT CENTER d z ELECTRIC PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 Et 0 oz ao Ct 0 5 Lo W Et THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY RED DOT CORPORATION AS A DESIGN BUILD CONCEPT. THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF SEA-TAC ELECTRIC, INC. FOR INFORMATION CONTACT: COREY MCKINNON - DIRECTOR OF DESIGN @ (253) 872-5553 REV # DATE DRAWN CM CHECKED CM DATE 03/07/2019 ELECTRICAL NOTES TADESIGN PROJECTS - PENDING\RED DOT\CAD\E2.01.DWG 3/7/2019 PANEL L1 (SEC 1+2) 150kVA XFMR PANEL H1 (SEC 1+2+3) .•.. I 1 .. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • iza tri SUB —DISTRIBUi",� 1AN 1200A, 480Y/277V, 3P, 4W, NENIA 1 • • • 1 Fastenal i NEW INJECTION MOLDING MACHINE • • • • • i 0-411 0 • animme • • • • • • • • • ICJ n (D. crg • 1■. "EN 11% • • • • • • • • • •• • \ 1..\\ mm. "ffill\ ma\:".1°%\al \\iv aim% \C.. \ %IL \ .1\ mi. ow • • • • irk \\-\\NR:%., N\h"•. • • • • • —MAIN DISTRIBUTION SWITCHGEAR (MDS) 1600A, 480Y/277V, 3P, 4W, NEMA 1 65,000 AIC r T T T I 1 L__ (2) 2-1/2" EMT (4) 250 KCMIL AL —' I i I . . . . \\,.\\\. NR.„ l __J L • fi (4) 3" EMT (4) 500 KCMIL AL ()#2GAL (2) 3" EMT (4) 500 KCMIL AL (1) #2G AL ------------------------------------------- • • • • • %\\::\\\\m"\\\\.\\\::%\\ \,_.<mm\S.N_\ ".°1 \ mi.• mi • • • % mn\\:\:\ ..%\\:\\"%.\\\*.t.\\% 11%.\\\%.1 W%\:%% \\\m\N:gl%\ a\ \\ %.\\ \las %-\\\:\ \\-\\...\\ \:\.\\ \\:\ \\:\ \\•.\•,. \Ns. \ \\\—\\. ma• • l • • • • • • • 1 1 Consignment • • • • • \\\•<%\:\\°••%%:9\:\-\\\''sna% ff•.\\ \\N, ,°. ��. �� °�. "°°._..� �'°■- •`. - . °■°■_•. ■, ■ems■. ■ Nik— \•:51 \1661\1 man_ \IN:°°_ ■ _ I '°4_ °- 7-/i POWER PLAN SCALE: 1/8" = 1'-0" -. \\\.\\ w%N. Ni\aa • ■° ■■° s s N "EL NI% \ "211,1 %%_ °■_ ■- °� 6 :L • • • BE\ PANEL COMP 0 GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. MULTI —WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4 REQUIREMENTS. 3. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALL BE AS SELECTED BY THE ARCHITECT, U.N.0.. VERIFY WITH ARCHITECT PRIOR TO ORDERING. 4. COORDINATE ALL CABLE PATHWAY ROUTING IN STRUCTURE, FINISHES AND OTHER TRADES PRIOR TO ROUGH —IN. 5. EQUIPMENT SHOWN BOLD IS NEW. 6. EQUIPMENT SHOWN DASHED IS EXISTING. • i • • °C°MPLIWED FOIL NFPA 70 -NEC �9AR 2 2 2019 City of Tukwila 15UILDIi4G DIVISION s 0 RECEIVED CITY OF TUKWILA MAR 0 7 2019 PERMIT CENTER U z 0 0 W J W PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY RED DOT CORPORATION AS A DESIGN BUILD CONCEPT. THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF SEA-TAC ELECTRIC, INC. FOR INFORMATION CONTACT: COREY MCKINNON - DIRECTOR OF DESIGN @ (253) 872-5553 REV # DATE DRAWN CM CHECKED CM DATE 03/07/2019 NORTH POWER PLAN E2.01 ISP OOct T: \DESIGN PROJECTS - PENDING\RED DOT\CAD\E5.01.DWG 3/7/2019 11:31 AM FEEDER SCHEDULE ALUMINUM EMT AMPACITY! ID NO RACEWAY WIRE COUNT SIZE OCP SIZE NOTES 03N 314" 4 - #8, 1#8 G. 30 / 30 60-deg rating 03 3/4" 3 -#8 1#8 G. 30 / 30 60-deg rating 04N 1" 4- #6, 1#8 G. 40 / 40 60-deg rating 04 1" 3 - #6, 1#8 G. 40 / 40 60-deg rating 05N 1 1/4" 4 - #4, 1#8 G. 55 / 50 60-deg rating 05 1" 3 - #4, 1#8 G. 55 / 50 60-deg rating 06N 1 1/4" 4 - #3, 1#8 G. 65 / 60 60-deg rating 06 1 1/4" 3 - #3, 1#8 G. 65 / 60 60-deg rating 07N 1 1/4" 4 #2, 1#6 G. 75 / 70 60-deg rating 7 1 1/4" 3 - #2, 1#6 G. 75170 60-deg rating 08N 1 1/4" 4 - #1, 1#6 G. 85 / 80 60-deg rating 8 1 1/4" 3 - #1, 1#6 G. 85 / 80 60-deg rating 10N 2" 4 - #1/0, 1#6 G. 120 / 100 75-deg rating 10 1 1/2" 3 - #1/0, 1#6 G. 120 / 100 75-deg rating 12N 2" 4 - #1/0. 1#4 G. 120 / 110 75-deg rating 12 1 1/2" 3 - #1/0, 1#4 G. 120/ 110 75-deg rating 13N 2" 4 - #210, 1 #4 G. 135 / 125 75-deg rating 13 2" 3 -#2/0, 1 #4 G. 135 / 125 75-deg rating 15N 2" 4 - #3/0, 1 #4 G. 155 / 150 75-deg rating 15 2" 3 - #3/0, 1 #4 G. 155 / 150 75-deg rating 18N 2 1/2" 4 -#4/0, 1 #4 G. 180 / 175 75-deg rating 18 2" 3 - #410, 1 #4 G. 180 / 175 75-deg rating 20N 2 1/2" 4-250kcmil, 1 #4 G. 205 / 200 75-deg rating 20 2 1/2" 3-250kcmil, 1 #4 G. 205 / 200 75-deg rating 22N 2 1/2" 4-300kcmil, 1 #2 G. 230 / 225 75-deg rating 22 2 1/2" 3-300kcmil, 1 #2 G. 230 / 225 75-deg rating 25N 3" 4-350kcmil, 1 #2 G. 250 / 250 75-deg rating 25 2 1/2" 3-350kcmii, 1 #2 G. 250 / 250 75-deg rating 27N 3" 4-400kcmil, 1 #2 G. 270 / 250 75-deg rating 27 2 1/2" 3-400kcmil, 1 #2 G. 270 / 250 75-deg rating 30N 3" 4-500kcmil, 1 #2 G. 310 / 300 75-deg rating 30 3" 3-500kcmil, 1 #2 G. 310 / 300 75-deg rating 34N 3 1/2" 4-600kcmil, 1 #1 G. 340 / 300 75-deg rating 34 3" 3-600kcmil, 1 #1 G. 340 / 300 75-deg rating 40N (2) 2 1/2" 4-250kcmil, 1 #1 G. 410 / 400 75-deg rating 40 (2) 2 1/2" 3-250kcmil, 1 #1 G. 410 / 400 75-deg rating 45N (2) 2 1/2" 4-300kcmil, 1 #1/0 G. 460 / 450 75-deg rating 45 (2) 2 1/2" 3-300kcmil, 1 #1/0 G. 460 / 450 75-deg rating 50N (2) 3" 4-350kcmil, 1 #1/0 G. 5001 500 75-deg rating 50 (2) 2 1/2" 3-350kcmil, 1 #1/0 G. 500 / 500 75-deg rating 60N (2) 3" 4-500kcmil, 1 #2/0 G. 620 / 600 75-deg rating 60 (2) 3" 3-500kcmil, 1 #2/0 G. 620 / 600 75-deg rating 75N (3) 3" 4-350kcmil, 1 #3/0 G. 750 / 750 75-deg rating 75 (3) 2 1/2" 3-350kcmil, 1 #3/0 G. 750 / 750 75-deg rating 80N (3) 3" 4-400kcmil, 1 #3/0 G. 810 / 800 75-deg rating 80 (3) 2 1/2" 3-400kcmil, 1 #3/0 G. 810 / 800 75-deg rating 90N (3) 3" 4-500kcmil, 1 #4/0 G. 930 / 900 75-deg rating 90 (3) 3" 3-500kcmil, 1 #4/0 G. 930 / 900 75-deg rating 100N (3) 2 1/2" 4-600kcmil, 1 #4/0 G. 1020 / 1000 75-deg rating 100 (3) 3" 3-600kcmil, 1 #4/0 G. 1020 / 1000 75-deg rating 120N (4) 3" 4-500kcmil, 1 #250 G. 1240 / 1200 75-deg rating 120 (4) 3" 3-500kcmil, 1 #250 G. 1240 / 1200 75-deg rating 150N (5) 3" 4-500kcmil, 1 #350 G. 1550/1500 75-deg rating 150 (5) 3" 3-500kcmil, 1 #350 G. 1550/1500 75-deg rating 160N (6) 3" 4-400kcmil, 1 #350 G. 1620/1600 75-deg rating 160 (6) 2 1/2" 3-400kcmil, 1 #350 G. 1620/1600 75-deg rating 200N (6) 2 1/2" 4-600kcmil, 1 #400 G. 2040/2000 75-deg rating 200 (6) 3" 3-600kcmil, 1 #400 G. 2040/2000 75-deg rating NOTE: Based on THHN insulation, EMT conduit and Chapter 9, Table 4 and Table 5a for compact AL wire, of the NEC, 2008 edition. * - Indicates acceptable overcurrent device rating for single feeder. This rating shall not be used for sizing parallel feeders. ** - Indicates overcurrent protective device rating that may be used for this feeder. The Contractor shall install feeder size indicated even if Code allows smaller to be used. GRADE EXTERIOR NEMA 3R EXISTING PSE UTILITY TRANSFORMER > 1 { < -LOOPED SWITCH L- XFM R VAULT INTERIOR NEMA 1 1SEKVICE LOAD CALCULATIICN SERVICE VOLTAGE 1-) 1EXISTIIdG MAIN SWWCH t1ARs) Si}ttB? 0 ESCRIPTION DEMAND PF KVA 1.25% TOTAL PEAK, DEMAND 412J2212017 O t2412G18, PSE MET ER. r420189137a5 4W..1& �J_90 449.L,? 112.27 IV IANUFACTC1RII`1G EQUIPMENT LOADS; €QViTIOlYTALWVY,tNEf DESCRIPTION HP V PH IPA,' EQWP l:W EQ IP AMPS A wV QTY NEC DMA la N€S REFERENCE TC'A<. NE:W EQUIP •41 NTLOA{) 1 4g0 I 3 375 321 _ 17.5•N 3 =i. 71 KVA TOTAL ANUFACT S)RIN?-. EOUFPMENT LOASPS=> KVA 0TAL L1 ART Ut LDLNG TOTAL EXISTING 1mAIN SWITCHBOARD SWIM 1 TOTAL Q LM,AND=> 561.33 KVA A TOTAL NEW MANUFACTURING EQUCPMENT LOADS===> 3S9 71 KVA TOTALzmw> 351.a KVA 11I1a3 Ai._:! 4$Liv' GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. RISER DIAGRAM IS NOT REPRESENTATIVE OF ACTUAL SWITCHBOARD LAYOUT. SEE ELECTRICAL ROOM(S) (SHEET E2.01) AND PANEL SCHEDULES (SHEET E5.02) FOR PHYSICAL LAYOUT WITH RESPECT TO ACTUAL MANUFACTURED AND POTENTIAL INSTALLED CONDITIONS. 3. EQUIPMENT SHOWN BOLD IS NEW. 4. EQUIPMENT SHOWN DASHED IS EXISTING. 5. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES PER NEC 408.4(B). r ELECT ROOM (6 SETS) 4" PVC-40 (4) 750KCMIL AL (EACH) T 1 0 0 LtD LID \ 1 1 T r-� JB , r-- JB JB T JB ,-'I I ( I II 1=74 ALL �y .LL ry 'LLit =1 < OLJ < QLJ < QLJ Q QL-' < QLJ O OCP O OCP O CD S O OS O Or-., 0-N 0 v C0(.0 , d-d- 1; �d- p, O(NN v 0_ 1'0 LL1 U 0_ (/) MAIN DISTRIBUTION SWITCHGEAR (MDS) 1600A, 480Y/277V, 3P, 4W, NEMA 1 65,000 AIC -1- T F JB T JB IP0_ I II ALL ALL rD < <L-J < QLJ DOr-.� 00'Tr r 0 O \ O O `, t , CO CO 1 -1 # --r r_-----• JB JB J3 AREA OF WORK NEW INJECTION MOLDING MACHINE (375A) • 400A 400AF k a_ Q p 0_ V) L1J U 0_ (1) 0_ LLJ U I - MAIN WATER PIPE EXOTHERMIC WELD OTHER APPROVED -r 3/0 CU PROVIDE UFER GROUND: 20' BARE COPPER CABLE IN CONCRETE FOOTING SIZED AND OR INSTALLED PER NEC 250-81(c) METHOD BOND TO MAIN WATER PIPE. PARTIAL ONE -LINE RISER DIAGRAM JB JB SCALE: NTS COMP ROOM L PANEL COMP 1000A MCB r 480Y/277V BRANCH DIST PANEL H1 (SEC1) 400A M LO L- T MACHINE SHOP PANEL H1 (SEC2) 400A MLO 1 J 208Y/120V BRANCH DIST PANEL L1 400A MCB _r_111J k-- I 150kVA ;vis XFMR 750 55 TON .j, I 753 330 TON 754 200 TON #3G I T • 751 460AF 100A r- j 100A J 50AF V J 50AF T � 80 TON 752 300 TON rr• .r, I 753 125AF 1lJ 125AF 1 330 TON r 754 200 TON 755 200 TON 756 55 TON I I I 100A ; lT, ;100A ; -100A ; �- J 100A 80AF �J 70AF �J 60AF ' T 50AF 757 P P Ld U a_ (f) 80 TON 758 .r. ?u 100A J 50AF 3- 720 TON T200AF 200AF 1 NEW SUB -DISTRIBUTION PANEL (SDP-1) 1000A, 480Y/277V, 3P, 4W, NEMA 1 65,000 AIC I qNED W O PA 70C NE TH N FC WAR 2 2 2919 City of Tukwila UILDING DIVISION RECEIVED Crry OF TUKWILA MAR 0' 2019 MIT CENTER PHONE (253) 872-5553 7056 SOUTH 220TH STREET FAX (253) 872-4112 KENT, WA 98032 0 5 0 74- •1 THESE DRAWINGS WERE DEVELOPED FOR EXCLUSIVE USE BY RED DOT CORPORATION AS A DESIGN BUILD CONCEPT. THEY ARE TO BE USED ONLY WITH WRITTEN PERMISSION OF SEA-TAC ELECTRIC, INC. FOR INFORMATION CONTACT: COREY MCKINNON - DIRECTOR OF DESIGN @ (253) 872-5553 REV # DATE DRAWN CM CHECKED CM DATE 03/07/2019 ONE -LINE RISER DIAGRAM