Loading...
HomeMy WebLinkAboutPermit EL19-0211 - BOWLERO - ELECTRICAL TENANT IMPROVEMENT AND NEW LIGHT FIXTURES & RECEPTACLESBOWLERO 100 ANDOVER PARK W SUITE 100 EXPIRED 11/10/19 ELI 9-0211 Parcel No: Address: �=^�x« °~� Tukwila "��~ «�o v��x����o�� � Department of Community Development 63005outhcenterBoulevard, Suite #1O0 Tukwila, Washington 981Q* Phnne:Z06-431'3G7O Inspection Request Line: 206438'9350 Web site: http://www.TukwilaWA.gov 0223000020 Project Name: 8OVYLEKD ELECTRICAL PERMIT Permit Number: EL19'02II Issue Date: 4/8/2019 Permit Expires On: 10/5/2019 Owner: Contact Person: Name: Address: Contractor: Name; License No: Lender: Address: OPEN FRAME iLC 923POWELL AVE SWBB101 C/O]SH PROPERTIES INC, RENTON, WA, 98057 APR|LHDLBE 3617SVV[HARLESTONST'5EATTLE WA, 98126 D[ELECTRIC INC 33lI763AVE VV,yWOUNTLAKE TERRACE, WA, 98043 D[ELEE1924ND ''' Phone: (206)478-0844 Phone: (206) 940-4963 Expiration Date: 8/18/2020 DESCRIPTION DFWORK: ELECTRICAL SCOPE FOR BOWLERO TENANT IMPROVEMENT, ASSOCIATED WITH PERMIT D18-0372, (12) NEW LIGHT FIXTURES, (Sl)RECEPTACLES Valuation of single family: $0.00 Valuation ofmVcomm: $117,000.00 Type ofWork: TENANT IMP Fees Collected: $2/44458 Electrical Service Provided by: PQGETSOUND ENERGY Water District: TUKVV|LA Sewer District: TUKVV|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: as Code: Permit Center Authorized Signature: National Electrical Code: VVACities Electrical Code: VVA[Z9646B: nergy Code: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work, I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. S: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: 3 —0 .19 Date Application Expires: 1 -` r 17 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 0223000020 Site Address: 100 Andover Park W, Tukwila, WA Suite Number: Tenant Name: Bowlero PROPERTY OWNER Name: Open Frame LLC Address: 14900 interurban Ave $ #130 City: Tukwila State: Wa Zip: 98168 CONTACT PERSON — person receiving all project communication Name: April House Address; 3617 SW Charlestown St City: Seattle State: WA Zip: 98126 Phone: Fax: 206-478-0844 Email: apnl©parolineassociates.com Floor: New Tenant: [ Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: DC Electric Address: 23117 63rd Ave W City: Mountainlake Terrace State: WA Zip: 98043 Phone: Fax: 206-940-0509 Contr Reg No.: DCELEEI924ND Exp Date: 08/18/20 Tukwila Business License No.; BvS,76,10999 / , Valuation of Project (contractor's bid price): $ 117,000 Scope of Work (please provide detailed information): Electrical scope for Bowlero tenant improvement, associated with permit #D18-0372: (12) new light fixtures, (52) receptacles. Will service be altered? ❑ Yes (K] No Adding more than 50 amps? Q Yes E No Type of Use: Tyne of work; ❑ New 51 Addition 0 Service Change 0 Remodel ❑x Tenant Improvement ❑ Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy 0 Seattle City Light W:\Permit Center\Applications-Handouts\Pcrmit Applications \PDFs \ Eletrical Permit Application Revised I-17-19.docx Page 1of2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm) $180.00 $120.00 ea $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $120.00 (no added/altered circuits) ❑ Service change with added/altered circuits $100.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $60.00 (up to 5 circuits) ❑ Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea ❑ Meter/mast repair $80.00 ❑ Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential)....... ............ ...... $60.00 ❑ Temporary service (generator) $90.00 ❑ Manufactured/mobile home service $100.00 (excluding garage or outbuilding) ❑ Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck $11,00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT' HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW OR ELECTRIC RACTOR: Signature: Print Name: Mailing Address: Z W:\Permit Center,Applications-nandouts\Pemnit Applications \PDF'slEkctricalPermit Application Revised I-17-19.docx State Zip Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK .`... PAID $2,444.58 E119-0211 Address: 100 ANDOVER PARK W 100 Apn: 0223000020 $2,444.58 ELECTRICAL $2,350.56 PERMIT FEE MULTI-FAM/COMM R000,322.101.00.00 0.00 $1,880.45 PLAN CHECK FEE R000.345.832.00.00 0.00 $470.11 TECHNOLOGY FEE $94.02 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17118 R000.322.900.04.00 0.00 $94.02 . $2,444.58 Date Paid: Friday, March 08, 2019 Paid By: PAROLINE & ASSOCIATES Pay Method: CHECK 8397 Printed: Friday, March 08, 2019 1:18 PM 1 of 1 $ STEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. P IIMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 'Project:' Type of Inspec on: . Address: 10 0It.f, Date Called: Special Instructions: ' Date Wanted: . . 5111 . Requester: Phone No: riApproved per applicable codes 1 1 Corrections required prior to approval. COMMENTS: *Inspect° Date:tos1/4 af REINSPECTI�N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspeclion. Q City of Tukwila Department of Community Development 10/1/2019 APRIL HOUSE 3617 SW CHARLESTON ST SEATTLE, WA 98126 RE: Permit No. EL19-0211 BOWLERO 100 ANDOVER PARK W - SUITE 100 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/10/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire: Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/10/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL19-021 l 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 C5 PERMIT COORD COPY o PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0211 PROJECT NAME: BOWLERO SITE ADDRESS: 100 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # DATE: 03/08/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 3-)-1-11 Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/12/19 Structural Review Required REVIEWER'S IN ALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 04/09/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg LJ Fire EJ Ping LJ PW LJ StaffInitials: 12/18/2013 Home Espanol Contact Search L&I Safety & Health Claims & Insurance Washington State Department of Labor & Industries A-Z Index Help My 1,&71 Workplace Rights Trades & Licensing D C ELECTRIC INC Owner or tradesperson Principals CASTOE, DANNY, PRESIDENT CASTOE, HEATHER, SECRETARY CASTOE, HEATHER, AGENT CASTOE, HEATHER, PRESIDENT (End: 07/30/2012) Doing business as D C ELECTRIC INC WA UBI No. 602 848 189 23117 63RD AVE W MOUNTLAKE TERRACE, WA 98043 206-940-4963 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License speciatties GENERAL License no. DCELEEI924ND Effective — expiration 08/04/2008— 08/18/2020 Designated administrator CASTOE, DANNY A License type Electrical Administrator Bond AMERICAN CONTRACTORS INDEM CO Bond account no. 100052096 Received by L&I 08/04/2008 ... No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. License no. CASTOD*98808 $4,000.00 Effective date 08/0112008 Expiration date Until Canceled Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. Help us improve 024,879-02 Doing business as D C ELECTRIC INC Estimated workers reported Quarter 4 of Year 2018 "4 to 6 Workers" L&I account contact T4 1 TERRI MADISON (360)902-4654 - Email: KIRT235@lnl.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects, Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period, itin; u7 Sta;e, Of,pt nt t_atp� r x , n'iustnP,, t,+se 0, thi cite fs s.tGjC Help us improve NOTE: GENERAL NOTES SHOWN HERE SHALL GOVERN FOR ALL ELECTRICAL SHEETS. CALLISOIRTKL ELECTRICAL SYMBOLS THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS OR ABBREVIATIONS ARE USED. V2.01 STANDARD MOUNTING HEIGHTS ANNOTATION LIGHTING (REFER TO LIGHT FIXTURE SCHEDULE FOR MORE INFO) LIGHTING CONTROL DEVICES, WIRING DEVICES & BOXES ELECTRICAL ONE -LINE & RISER DIAGRAM AUDIBLE APPLIANCES ALARMS ANNUNLIATOP PANELS CONTROLS (TOP C£DEVFDE) EXIT SIGNS (WALL MOUNTED) FIRE ALARM ANNUNCIATOR FIRE ALARM SELL {ROLPANR)(CEMERUNE)DISMAY FIRE ALARM CONTROL INTERCOM (AFEA ONLY) INTERCOMS (TOP OF PULL STATIONS (TOP PHOTOCELLS RECEPTACLES RECEPTACLES (EXTERIOR) RECEPTACLES (GARAGES) RECEPTMAES(POOLS) (CENTERLWE) B � (DISPLAY) SP• A6 9P PANEL (XSRAY) 80' 120' PANELINIT(DIBRAY) 8d SC DEVCE) •6 OF DEVICE) 18 14L• 16 241 24' 2T MECHANICAL O0. FIRE PROTECTION PLAN N3TEGLLCVr 1 PLUMBING PLAN NOTE O 0 ELECTRICAL OR FIRE ALARM PLAN MOTE CAL.WT TECHNOLOGY PLAN O PLUMBING EQUIPMENT DES/ONATIOIR.(CONRNCTOR FURNISHED AND F FIXTURE SINGLE POLE SWITCH MO LETTER DESIGNATION) SWITCH LETTER DE9IGNATdde AS FOLLOWS: 2 • TWO POLE 3=THREE-WAY RWAY 4 • DIMMER y F • FAN SPEED CONTROL K•KEYED I� lv ITIM ❑ IK••, AIM _ {• il ^PT I7 L�- {i m SWITCH (RATING AS INDICATED)0LIGHT DAWOUT CIRCUIT BREAKER(RATINGS AS INDICATED ) FUSED SWITCH (RATING. POLES AND FUSE TYPE AS INDICATED) COMBINATION FUSEDBWTH9MI CTARTERDSTARTERN2E CIRCUIT BRFAKFR(RATINGS A8 INDICATED) COMBINATION CIRCUIT BREAKEPSTARTER AND STARTER SIZE PANELBOARD, SINGLE OR MULTI -SECTION (REFER TO SCHEDULES) POWER PPNELBOMDW/INIEGRµ TMXSFOAEA (REFERBATED PANE TRANSFORMER OWE AND MTNGSg91HDICATW) SHIELDED TRANSFORMER TYPE AND RATINGS AS INDICATED) a"� O P • SWITCHED BY SWITCH -B' A =DIG TFIXTURETYPE'A' Q LC 1 • WALLMOLIYT TV 0 0> =ANROW INDICATES AIMING DIRECTION LOW VOL VOLTAGE OS LV •LOWVOLNCYSEMSdR P= SPST PILOT UUGHTme VS • VACANCY SENSOR WP • WEATHER PROOF DRAUTOMATIC LOAD CONTROL RELAYcur AB 1=j19 BRANCH CIRCUIT TRANSFER SWITCH m ►_, UGHT FIXTURE CIRCUITED AS A NIGHT LIMIT (NL) ( 1 ) INSTALLED), REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES ® EMERGENCY LIGHT FIXTURE WITH EMERGENCY LIGHTING BATTERY r. PACK OR CONNECTED TO EMERGENCY SOURCE RECEPTACLES ABOVELWNTEN ( RECEPTACLES IN EQUIPMENT REMOTE INDICATING REMOTE INDICATING SAFETY SWITCHES (TOP STARTERS (TOP OF DEVICE) SWEPHEBTOPCf DEVICE) TELEPHONE DATA OUTLETS TELEPHONELTERMINOUTLETS TELEVISION ARRANGES WSIBLEAPPLIAXCEg ROOMS •6'ABOVE BALKSPLABXKOUN1FA, b'IM% M• LIGHT (EQUIPMENT ROOMS) 48• LIGHT (FINISHED AREAS) CEILING OF DEVICE) 48' 48' O SAME AS ADJACENT DEVICE. UNO BOARD (BOTTOM) REFER TO ARCH DRAWINGS (CEXTERLIE) M' 1 EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) W MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED , NIGHT LIGHT,/EMERGENCY LIGHT FIXTURE WITH EMERGENCY BATTERY PACK OR CONNECTED TO EMERGENCY SOURCE PACK SIMPLEX RECEPTACLE-NEMA 5.20R, UNO y IJP DUPLEX RECEPTACLE- NEMA SBIR UNO J2 g DOUBLE WPtFY.RECEPTACLE-NEAHSSQ UNO 6 SPECIAL RECEPTACLE - NEMA TYPE AS NOTED . TWIST -LOCK TYPE RECEPTACLE AND INSTALLED UNLESS NOTED OTREAWIS V M S CONNECTION POINT OF NEW WORK TO EXISTING Q NAIL REFERENCE UPPERNVMET NUMBERTESDETAILNAIBER ® LOWER NUMBER INDICATES SHEET NUMBER LIGHT FIXTURE WHIR OVAL BALLASTS CIRCUITED SEPARATELY (SHADING IMPLIES EMERGENCY LIGHT FIXTURE) LIGHTING TRACK WITH LIGHT FIXTURE TYPES AS INDICATED USE THE DEFAULT MOUNTING DOCUMENTS MOUNTING FINISHED GMOE(AEG)TO COMPLIANCEWITHCURRENTAGANDLDLKREOUPDAENB. HEIGHTS SHOWN ABOVE UNO IN THE WMi1RUCTIOXvvo HEIGHTS LISTED ARE ABOVE FINISHED FLOOR (AFF) OR ABOVE BOTTOM OF OWLET BOX ALL DEVICES NViL�INSTALLED IN aL_1C MIRROR LIGHTS P.- I �� ' --- O�y1 FI O•,I, AUTOMATIC TRANSFER SWITCH (RATINGS AS [INDICATED)L_.r AUTOMATIC TRANSFER SWITCH WITH BYPASS (RATINGS AS INDICATED) fil SECTION CUT DESIGNATION ABBREVIATIONS /.// 'A_� 0•0 EXTERIOR SITE PARKING LOT LIGHT FIXTURE © EXTERIOR PEDESTRIAN POST TOP UGHT FIXTURE 0 EXTERIOR LIT BOLLARD LIGHT FIXTURE RI EXIT SIN- CEILING I WALL MOUNTED, ARROWS AS INDICATED. FACE ® Y HATCHED �p LIGHTING EQUIPMENT WITH BATTERY PACK- 1�3 LJ ILIN ALL OUNTED FOR SAWAI INDICATED 9T,WCE)EON -fEILINDWAl1 ® MOUNTED. MOUNTED. ARROW8A9 AF AMPERE FRAME SIZE AFC ABOVE FINISHED CEILING ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE PHJ AUTHORITY RAVING MC8 MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MFR MANUFACTURERAFF MIN MINIMUM MA MAIN LUGS ONLY 4OR0 L VOR0 a..-..E-. 6 y� yp TF [li] 11;6RECEPTACLE YWMw VB GFCI GFCI TYPE RECEPTACLE* ISOLATED GROUND TYPE RECEPTACLE" uEM EMERGENCY RECEPTACLE' RECEPTACLE INSTALLED ABOVE COUNTER OR BACKSPLASW RECEPTACLE INSTiLLEDINCE&IW RECEPTACLE INSTALLED w FLOUR• INSTALLED VIA DROP CORD• RECEPTACLE LETTER DESIGNATIONS AS FOLL0'N8: C•AUTOMATICALLY CCMROLED CH CLOCK HANGER TYPE D•DEMWI9HED EMT EMERGENCY EM=EGROUND-FAULT POLYER GFCI=NTALLY CIRCUIT INTERRUPTER H= HORIZONTALLY MOUNTED IG=ISOLATED GROUND R • RELOCATED S = SWITIT LED USB • DUPLEX WP • WEATHER PROOF COVER WR • WEATHER RESISTANT ASSEMBLY CIRCUITING & WIRING 753 IOMERUN TO PANELI3OARD. INFCRIMTION AT ARROWS ARE CIRCUIT OR-El P1.3.5.7 NUMBERS AND PANELBOARD FOR TERMINATOR REFER TO P1 PANELBOARD SCHEDULES FOR BRANCH CIRCUIT CONDUCTOR SEES. JURISDICTION AHU AIR HANDLING UNIT AIC AMPERE INTERRUPTING CAPACITY AS AMPERE SWITCH AT AMPERE TRIP SETTING AOR AV8 AUDIOSUAL TRANSFER SWITCH RASS BUILDING AUTOMATION SYSTEM BNfl BREN(ER C OONWR CAT CATEGORY CATY CABLE TELEVISION SYSTEM CCTV CLOSED CIRCUIT TELEVISION CO CANDELA CKT CIRCUIT CODE APPLICABLE CCOE ADOPTED BY JURISDICTION CT CURRENT TRANSFORMER CT0. GENTE0. CVD CUMULATIVE VOLTAGE DROP M0CP MAXIMUM OVERCURRENT PROTECTION MTD MOUNTED WA NOT APPLICABLE NE NON -FUSED NL NIGHT LIGHT (24HR ON) NRR TRAES1NOLABORA Y OB OCCWANCY SENSOR P POLE PPFT PARTAL CIRCUIT PHP PHASE PM. PANEL PNLBD PANELBOARD PROVIDE FURNISH AND INSTALL PT POTENTIAL TRANSFORMER OTT QUANTITY RCFT RECEPTACLE RELO RELOCATE RLA RUNNING LOAD IMPS RTU ROOFTOP UNIT w GENERATOR (RATINGS AS INDICATED) ' ^� T CIRCUIT CONTINUATION OR PARTIAL CIRCUIT � NON DERIVED -SEPARATELY SOURCE \ � --- N_ �1 CONDUIT CONCEALED - �_ CONDUIT INUNDER ROgVGROUND CONSTRUCTION EXPOSEDCONDUI /\ \/ FLEXIBLE COIDUR LOW VWTAf£CABLE (NOT ROUTED IN CONDUIT) MDP vne• SEPARATELY DERIVED SOURCE un BMIELBO AR. BWTBOARDRATING ANDIOR ION �- EVICES IDAC AS MD (TYPE RATING, DEVICES AND ACCESSORIES ESS AS INDICATED) POWER EQUIPMENT B DEVICES ©© COMBINATION DIGITAL VOLT MEIEWAMMETER wow ELECTRICAL PANELBOARD (SURFACE OR FLUSH MOUNT) p CIRCUIT IDENTIFICATION (REFER TOdRCIlT4dfEDJLE) G O TERMINAL CABINET(SURFACE OR PUSH MOUNT). TYPE AS NOTED PLYWOOD TERMINAL BOARD FOR TELEPHONE SYSTEM. UNO. SIZE AS GFR GROUND FAULT RELAY -0 CONDUT TURNING DOWN TURNING UP DEMO DEMOLITION OPDT DOUBLE POE, BCCR SHORT-CIRCUIT WF EKT PAYING NOTED PFR PHASE FAILURE RELAY DOUBLE -THROW mHT DOUBLE -POLE, SINGLE -THROW (E) EXISTING EC ELECTRICAL CONTRACTOR Ei EXHAUST FAN EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM ETR EXISTING TO REMAIN EWC ELECTRIC FAAP FIRE AARMNUTOR PANEL FACP FEE ALARM CONTROL PANEL FG FAULT CURRENT MAPS AVAJIABLE ECU FAN COIL UNIT SD SMOKE DUCT Ot 1Un SF SQUAREFEET-0 SPOT SINGLE -POLE, DOUBLE -THROW &PST SINGLE-POLE.HAM1IPERY SIXOLEIXROW ST SHUNT TRIP BWBD SWITCHBOARD SWGR SWITCHGEAR TBB TELECOMMUNICATIONS TBD DETERMINED TOB TELECOMMUNICATIONSMULTbUTLET GROUND BUS BAR T. TW191LOCK 1TELEWMMVNXATION4 Mary M[E CONDUIT ` CONNECTION POINT OR EQUIPMENT TERMINATION jj��, SWITCHBOARD OR MOTOR CONTROL CENTER ON HD I•FYFFPING PAD IUry KIRK -KEY INTERLOCK N INDICATES KEY PAIR) EQUIPMENT TERMINATION ����/ ELECTRICAL DISTRIBUTION PANELBOARD BT SHUNT TRIP umny" © El din AMMETER (RANGE AS SPECIFIED OR REQUIRED) VOLTMETER (RANGE AS SPECIFIED OR REQUIRED) UTILITY METER (AB REpmfEDBTUTLITY) O TRANSFORMER CONDUCTOR TICK MARK LEGEND 'O MOTOR 2oNalsorm DISCONNECT SWITCH- Z02/615036 DENOTES SP AMPEREOLE/FUSE/1EIM ENCLOSURE RATING. NF=NONFUSED. CB• CIRCUIT BRFAYFR(2WINE), NO VALUE (2009/IE4 FOR NEMA ENCLOSURE MEANS STANDARD NEMA I RATING COMBINATION DISCONNECT(SAFETY) SWITCH AND MOTOR STARTERGEC 9R '3WL1S'ATION DISCON AMPERESPOEFU CHANMOTORRQ ABSIZEINEMA m ® V TELEPHONE OUTLET V DATA OUTEf MULTLNILE OUTLET; TELEPNOXEANDDATA WUNIER TGFR WHERE TICK NARKS ARE SHOWN. THE FOLWnNG SHALL GOVERN SWITCHED HOT (PHASE)CONDUCTORS (SHOWNTRAILING NEUTRAL) NEUTRAL (GROUNDED)CONDUCTOR NOT(PASE) CONDCTORS(SOWN LEADING NEUILL 1OE9 NOTE: HASH MARKS INDICATE QGANTTY OF CONDUCTORS EQUIPMENT GROUNDING CONDUCTOR IN WJWT(GREEN OR BARE) METER jP 9 D 15 SWITCH VOLTMETER SWITCH WATT-HOUR METER, V DENOTES DEMAND REGISTER 'IS DENOTES MINUTES OF DEMAND INTERVAL CURRENTITWISFOMAER RATING ASSPECIFIED ORRpUIRED POTENTIAL TRANSFORMER FIRING AS SPECIFIED OR REQUIRED FF FINISHED FLOOR FIA FULL LOAD HIPS RR FLOOR GCE GENERALNCONTRACTOR GROUNDING EIELTRODB CONDUCTOR GROUNDING ELEOTRCOE SYSTEM GROUND FAULT RELAY O GROUND IG ISOLATED GROUND IBC SHORTINSULATION CIRCUIT CURRENT .IB/J-BOX LRA LOCKED ROTOR AMPS LTGLTS IMEEMP AIRUNI MA MuX'IMUMURIMT MCA MINIMUM CIRCUIT AMPACITY GROUND BUS OAR TX TRANSFORMER TYP TYPICAL UR UNDERFLOORU U10 UNDER U/S UNOE0.9lAB UNO UNLESS NOTED OTHERWISE4UNSWITCHED UH UNIT HEATER UPS UNINTEGRLPIIBLE POWER SUPPLY VD VOLTAGE DROP® W VARIABLE FREOUENCYORIVE WI WIITRH WP WEATHER PROOFm WI Wniertiw RESISTANT XP EXPLOSIONPRCOF ENCLOSURE RATING.NF= NONFUSED. CS=CIRCUITABQE BREAKER(SBnICB(1). NO VALUE(200T115W1) FOR NEMA ENCLOSURE ME.WSSTANDARD NEMAI ENCLOSURE RATING WALL, Tw Q FLOOR TIP A MULTI -SERVICE POWER POLE WITH TELEPHONE GTAPIDPCNIII OUTLETS A = TYPE. REFER TO PLANS. SCHEDULES AND aA MULTI -SERVICE FLOOR BOX WITH TELEPHONE. DATA AND POWER OUTLETS A = TYPE, REFER TO PLANS, SCHEDULES MO SPECIFICATIONS OA POKE THROUGH. A • TYPE. REFER TO PLANS, SCHEDULES AND SPECIFICATIONS THERMOSTAT ® JUNCTION BOX/OUTLET BOX • BLANK FACE GFCI FEED THROUGH DEVICE AAGNETIC MOTOR STIRRER. NEMA SIZE AS NOTED.3RXE, UFO 24 MANUAL MOTOR9TARTER DISCONNECT �%NSPECIFICATIONS a FRACTIONAL HORSEPOWER MANUAL CONTROLLER $th INTEGRAL HORSEPOWER MANUAL CONTROLLER VARIABLE FREQUENCY DRIVE ISOLATEOObUNdNGCONDUCTOR IN CONCUR (GREEN INSULATION WITH YELLOW TRACER) BRANCH CIRCUIT CONDUCTOR TABLE WHERE TICK MARKS P OF POLES ARE NOT SHOWN. THE HOT (PHASE)* FOLLOWING SHALL GOVERN: NEUTRAL (GROUNDED)" GR01ND*16•• SPD BURGEPROTELTIVEDEv10E .--III GROUND CONNECTION GROUND CONNECTION WITH TEST WELL SOH GROUND ROD IP (1) (1) WA (1) 2P (2) (1) MA (1) ® RELAY OR CONTACTOR (IN SCHEMATICS) CONTACTOR (SIZE. COIL VOLTAGE MID NUMBER OF POLES AS INDICATED) TIME SWITCH NORM P:EL_ INDICATING LIGHT EMERGENCY POWER OFF BUTTON 9P (3) (1) UNIT (1) NURSE CALL (HOSPITAL) II �.--III LIORTNING ARRESTER I H I 1 CAPACITOR = CONTACT (OPEN OR CLOSED) NM HEATER MOTORACY Q CODE BLUE PUSHBUTTON STATION ]'L BED RECEPTACLE • PROWDEAmITIOWLLCONDUCTORS GTIO DOLLMENB TIOND CU TTHROUGHOUTC CONSTRICTION UNSWITCHEDIEM.D ETC.) AS INDICATEEAND AND AS REQUIRED FORA COMPLETE AND WORKING SYSTEM. WORKING SYSTEM. ^ REFER TO SPECIFICATIONS FOR LIMI ATIONS ON SHARING NEUTRAL (GROUNDED) DO NOT CIRCUIT AS A MULTI -WIRE BRANCH CIRCUIT, UN]. 1"• PROVIDE ADDITIONAL ISOLATED GROUNDING CONDUCTORS WHERE INDICATED.® REFER TO SPECIFICATIONS. PLANS. NOTES. WIRING AND CONTROL DIAGRAMS FOR ADDITIONAL CIRCUITING REQUIREMENTS. _ r DUTY STATION 13CONDUCTORS. STAFF EMERGENCY ASSIST STATION ® PATIENT EMERGENCY PULL COO STATION 0 INTERCO/A 13 NURSE CALL KEY SCOTCH ® NURSE CALL BEDSIDE STATION -SINGLE PATENT N2 NURSE CALL BEDSIDE STATION DOUBLE PATIENT ® NURSE CALL VISUAL ANNUNCIATOR PANEL L�. STAFF STATION (NORMAL EMERGENCY SCOOE BLUE) �n NURSE CALL MASTER STATION yyI�•LT� ea., DONE LIGXT-CEILIN3MOUNTED,B•BUZZER GEFINITON98PEdFlC DEFINITIONS 'SYMBOL OTHER SSPECIFICTO IS DEVICEOJESCHEDULE FOR ADDITIONAL DEVICE BFMBM9AND TOTHIS PWJELT. DEMONSTRATED WITH DUPLEX RECEPTACLE. WHEN USED IN COMBINATION WITH DEVICES MEANING IS SIMILAR FOR THOSE DEVICE TYPES. LINETYPE LEGEND LINETYPES ARE USED N COMBINATION WITH THROUGHOUT THE THE STATUS OF THE SYMBOLS INDICATETOTHE STATU90F ITEMS AS EXISTING, TO BE DEMOLISHED. TO BE INCLUDED AS PART OF NEW WORHANDT ITEMS WHICHMEPMICIPATEDTO BE PROVIDED IN THE FUTURE. THE STATUS OF ITEMS USING THESE LINETYPES ARE RELATIVE TO THE VIEW IN WHICH THEY APPEAR. PHAS NO SHOWN IN DRAWINGS IS NOT INTENDED TO FULLY DESCRIBE ALL NECESSARY CONST UCTION PHASING, WHICH IS DETERMINED BY THE CONTRACTOR AS PART OF THEIR RESPONSIBILITIES, ANY SUCH PHASES DESCRIBED IN THE CONSTRUCTION DOCUMENTS ARE GE ERAL AND ONLY INTENDED TO INDICATEA BROAD ORDER FOR THE SAKE OF DESCRIBING THE PROJECT. THE FOLLOWING LINETYPES MAY BE USED ON ANY DEVICE, EQUIPMENT. NOTE ME SHAPE, ETC. EY BLOCK LOAD KW OR KW Q STOP -START PUSH BUTTONCCNROLSTATION XFB X FPS FAULT POINT REFERENCED IN SHORT CIRCUIT CURRENT AJO VOLTAGE DROP SPREADSHEET SIGNALING -II: HAND -OFF -AUTO PUSH BUTTON CONTROL STATION MUSHROOM -TYPE PUSH BUTTON Skim/ OVERHEAD PADDLE FAN D. j� SIGNALING BELL IL 17 A SIGNALING e112JFR LYTRANBFORMFR HD DOME ZB� IV DOME LIGHT - WALL MOUNTED. B• BUZZER EXISTING NEW FUTURE -- V ZONE DOME LIGHT. B • BUZZER ELECTRICAL GENERAL NOTES: READ THE SPECIFICATIONS MID REVIEW DRAWINGS OF ALL DIVISIONS OF WORK COORDINATE THIS WORK WITH ALL OTHER DIVISIONS OF WORK AND ALL SUBCONTRACTORS. PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2 ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND REPRESENT THE GENERAL SCOPE OF THE WORK. SIZES AND LOCATION OF EQUIPMENT AND WIRING ARE SHOWN TO SCALE WHERE POSSIBLE, BUT MAY BE DISTORTED FOR CLARITY ON THE DRAWINGS. FINAL LOCATION OF OUTLETS AND EQUIPMENT SHALL BE AS APPROVED BY THE ARCHITECT OR THEIR REPRESENTATIVE. IT IS NOT WITHIN THE SCOPE OF DRAWINGS TO SHOW ALL NECESSARY BENDS, OFFSETS. PULL BOXES MID OBSTRUCTIONS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL ALL WORK TO CONFORM TO THE STRUCTURE. PRESERVE HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAN. 3. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAY NOT REFLECT EXACT 'AS -BUILT CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. 4. SECURE MID PAY FOR ALL PERMITS AND FEES NECESSARY FOR EXECUTION AND COMPLETION OF ELECTRICAL WORK. FURNISH TO THE ARCHITECT A COPY OF INSPECTION REPORTS AND APPROVAL CERTIFICATES FROM LOCAL AND STATE INSPECTIONS. 5. ELECTRICAL CONTRACTOR SHALL REQUEST A SET OF ARCHITECTURAL PLANS FOR REFERENCE FROM THE GENERAL CONTRACTOR 8. OBTAIN A COPY OF AND REVIEW THE LANDLORD'S LATEST EDITION OF TENANT DESIGN AND CONSTRUCTION CRITERIA AND COMPLY WITH ALL REQUIREMENTS. WHERE CONFLICTS BETWEEN CRITERIA AND CONSTRUCTION DOCUMENTS ARISE. NOTIFY ARCHITECT/ENGINEER IMMEDIATELY. t. ALL ELECTRICAL WORK SHALL BE PERFORMED IN COMPLIANCE WITH CURRENT NEC. OTHER LOCAL CODES AND LANDLORD CRITERIA. UPON COMPLETION OF ALL ELECTRICAL WORK, ELECTRICAL CONTRACTOR SHALL ADJUST AND TEST ALL CIRCUITS, OUTLETS. SWITCHES, LIGHTS, MOTORS, MID ANY OTHER ELECTRICAL ITEMS. DAMAGED ITEMS SHALL BE IMMEDIATELY REPAIRED OR REPLACED WITH ALL NEW EQUIPMENT AND THAT PART OF THE SYSTEM SHALL THEN BE RETESTED. ALL SUCH REPLACEMENT OR REPAIR SHALL BE DONE AT NO ADDITIONAL COST TO THE OWNER 9. AFTER COMPLETION OF WORK UNDER THIS SECTION, CLEAN-UP ALL RESULTANT DEBRIS FROM THIS WORK AND REMOVE FROM THE SITE. 10. VERIFY LOCATIONS FOR ALL ELECTRICAL EQUIPMENT WITH ARCHITECTURAL DRAWINGS FOR INTERIOR DETAILS AND FINISH. IN CENTERING OUTLETS AND LOCATING BOXES AND OUTLETS, ALLOW FOR OVERHEAD PIPES, DUCTS AND MECHANICAL EQUIPMENT, VARIATIONS IN FIREPROOFING AND PLASTERING, WINDOW AND DOOR TRIM. PANELING, CEILING AND ASSOCIATED CONDITIONS. AND CORRECT ANY INACCURACY RESULTING FROM FAILURE TO DO SO WITHOUT EXPENSE TO OWNER. 11. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH ALL TRAnWS AND ELECTRICAL REFERENCES ON ARCHITECTURAL DRAWINGS. 12. COORDINATE ALL ELECTRICAL WORK OUTSIDE OF TENANT SPACE WITH LM4DLORD TO ENSURE MINIMAL DISRUPTION. ALARM AND EMERGENCY SYSTEMS SHALL NOT BE INTERRUPTED UNLESS APPROVED BY THE OWNER 13. COORDINATE EXACT ROUTE FOR INSTALLATION OF ELECTRICAL AND TELEPHONE SERVICES IN THE FIELD WITH LANDLORD OR BUILDING ENGINEER REFER TO ONE -LINE DIAGRAM FOR ADDITIONAL TELECOMMUNICATION SYSTEM REQUIREMENTS. 14. FIELD VERIFY EXACT LOCATION OF LANDLORD SHELL BUILDING DUCTWORK MID PIPING. NOTIFY ARCHITECT/ENGINEER IMMEDIATELY IF NEC REQUIRED CLEARANCES FOR TENANT PANELBOARDS ARE NOT MET DUE TO SHELL BUILDING SERVICES ROUTED ABOVE TENANT SPACE. 15. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING OF THE EXISTING CONSTRUCTION WORK WHICH MAY BE REQUIRED FOR THE PROPER INSTALLATION OF THE ELECTRICAL WORK ALL PATCHING SHALL BE OF THE SAME MATERIALS, WORKMANSHIP AND FINISH. AND SHALL ACCURATELY MATCH ALL SURROUNDING WORK. I6. FOR ALL SLAB PENETRATION& THE METHOD, DEPTHS, AND LOCATIONS SHALL BE PRE -APPROVED av BUILDNG FIELD REPRESENTATIVE PRIOR TO THE START OF WORK. SLAB REPLACEMENT SHALL BE INSTALLED WITH DOWELING AND REINFORCED CONCRETE OR AS DIRECTED BY FIELD REPRESENTATIVE. WHERE SLAB IS SAW -CUT AND REMOVED FOR TRENCHING THE CONTRACTOR SHALL INSTALL MOISTURE BARRIER PER LANDLORD'S REQUIREMENTS. 17. COORDINATE ALL CONCRETE TRENCHING TO ENSURE THAT ANY UNDER SLAB UTILITIES ETC. ARE NOT DAMAGED DURING FLOOR CUT. ANY DAMAGE INCURRED SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE. PRIOR APPROVAL AND COORDINATION WITH PROPERTY MANAGEMENT IS REQUIRED FOR ALL CONCRETE CUTTING. 18. ALL PENETRATIONS THROUGH FIRE RATED WALLS. FLOORS OR PARTITIONS SHALL BE PROPERLY SEALED TO PREVENT THE SPREAD OF SMOKE AND FIRE. THE RATING OF THE PENETRATION SEAL SHALL AT A MINIMUM BE THE SAME RATING AS THAT OF THE WALL, FLOOR OR PARTITION ASSEMBLY. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 19. PROVIDE A SEPARATE CODE SIZED GREEN EQUIPMENT GROUND CONDUCTOR IN ALL CONDUITS AND RACEWAYS CONTAINING LINE VOLTAGE CIRCUITS. FOR ALL 20A CIRCUITS. EQUIPMENT GROUND CONDUCTOR SIZE SHALL MATCH PHASE CONDUCTOR SIZE. FOR CIRCUITS UPSIZED FOR VOLTAGE DROP INCRFASF EQUIPMENT GROUNDING CONDUCTOR SIZE PER CODE. 20. ALL WIRING SHALL BE IN RACEWAY (EMT OR RIGID). FLEXIBLE METAL CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC.. MAXIMUM LENGTH (8) FEET. NO 'BX,'ROMEX ARMORED CABLE, ETC., ALLOWED. 21. EXPOSED CONDUIT SHALL BE INSTALLED IN STRNGHT LINES, PARALLEL WITH OR AT RIGHT ANGLES TO THE BUILDING STRUCTURE DO NOT LOOP EXCESS FLEXIBLE CONDUIT IN CEILING SPACE. 22. FLEXIBLE CONDUIT IS NOT PERMITTED WITHIN DEMISING WALLS AND IS ONLY ALLOWED FOR FINAL CONNECTIONS OF SO" OR LES& 23. HORIZONTAL OR CROSS RUNS OF CONDUIT AND WIRING IN WALLS AND PARTITIONS IS NOT PERMITTED. 24 PASS RACEWAYS OVER WATER AND OTHER PIPING WHEN PULL BOXES ARE NOT REQUIRED. NO RACEWAY WITHIN 3" OF HOT WATER PIPES, OR APPLIANCES, EXCEPT CROSSING WHERE RACEWAY SHALL BE AT LEAST 1" FROM PIPE COVER. 25. SECURE ALL SUPPORTS TO BUILDING STRUCTURE AS REQUIRED. SUPPORT HORIZONTAL RUNS OF METALLIC RACEWAYS NOT MORE THAN TEN FEET APART. 28. COORDINATE FINAL CONNECTION LOCATIONS, TYPES, AND REQUIREMENTS FOR DIVISION 15 EQUIPMENT WITH DIVISION 15 CONTRACTOR PRIOR TO ROUGH -IN. _ 27. PROVIDE NYLON BUSHINGS FOR ALL CONDUIT STUB -UP LOCATIONS TERMINATED WITHOUT A JUNCTION BOX UNLESS NOTED OTHERWISE. 28. ALL JUNCTION BOXES SHALL BE RIGIDLY ATTACHED TO STRUCTURE OR MILLWORK. 29. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO MILLWORK. CONFIRM FINAL CONNECTION LOCATION AND REQUIREMENTS WITH MILLWORK CONTRACTOR PRIOR TO ROUGH -IN. 30. PROVIDE ALL MISCELLANEOUS STEEL AS REQUIRED FOR THE PROPER INSTALLATION OF ELECTRICAL EQUIPMENT AND SYSTEMS. 31. ALL ELECTRICAL DEVICES AND COVER PLATES SHALL BE "DECORA' STYLE. 32. PROVIDE UPDATED TYPE -WRITTEN PANELBOARD SCHEDULES AT ALL EXISTING PANELBOARDS AFFECTED BY WORK AND FOR ALL NEWLY INSTALLED PANELS. SCHEDULES SHALL REFLECT AS -BUILT CONDITIONS. TRACE ALL EXISTING CIRCUITS TO VERIFY AND UPDATE SCHEDULES 33. COORDINATE FINAL LOCATION, MOUNTING HEIGHT, AM) COLOR OF ALL UGHT FUTURES, WALL MOUNTED AND CEILING MOUNTED DEVICES WITH ARCHITECT PRIOR TO ROUGH4N. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING MOUNTED DEVICES AND LOCATIONS. ALL CEILING MOUNTED DEVICES SHALL BE EVENLY SPACED FROM ADJACENT LIGHT FIXTURES WHEN POSSIBLE 34. LIGHT FIXTURES AND ASSOCIATED EQUIPMENT SHOWN ON ELECTRICAL DRAWINGS REPRESENT GENERAL ARRANGEMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR MORE EXACT LOCATIONS. COORDINATE LOCATIONS WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS. 35. ALL ELECTRICAL IN SHOW WINDOWS (FLOOR OR CEILING) MUST BE DISCRETE. PAINTED TO MATCH ADJACENT SURFACE MID FLUSH WITH SURFACE. 36. PROVIDE UN -SWITCHED HOT LEGS TO ALL EXIT SIGNS. EMERGENCY FIXTURES (EM), NIGHT LIGHTS (NL) AND FIXTURES EQUIPPED WITH BATTERY BACKUP RM I AST. REFER TO LIGHT FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. 37. PROVIDE NEUTRAL CONDUCTOR TO ALL WALL UGHT SWITCH LOCATIONS. IF NEUTRAL TERMINATION IS NOT REQUIRED, CAP CONDUCTOR AND TAG AS "NEUTRAL FOR FUTURE USE'. 38. PROVIDE A DEDICATED NEUTRAL FOR ALL DIMMED LIGHTING CIRCUITS. 39. PROVIDE ALL REQUIRED MOUNTING MID SUPPORT HARDWARE FOR UGHT FIXTURES TO MEET SPECIFIED MOUNTING HEIGHT& 40. PROVIDE A FACTORY -INSTALLED MAXIMUM WATTAGE LABEL THAT CORRESPOND TO THE MAX:MUM WATTAGE INDICATED IN THE LIGHT FIXTURE SCHEDULE ON ALL MEDIUM SCREW BASE LIGHT FIXTURES. 41, REFER TO ARCHITECTURAL SHEETS FOR POWER, SECURITY, AND AN DEVICE LEGENDS AND ADDITIONAL INFORMATION. 42. CONTRACTOR SHALL PROVIDE AND INSTALL ON ALL SWITCHBOARDS AND PANELBOARDS A CUSTOM DIGITALLY PRINTED AND HIGH -DURABILITY LAMINATED LABEL RATED FOR OUTDOOR APPLICATIONS. LETTERING SHALL BE A MINIMUM OF X" HIGH YELLOW BACKGROUND WITH BLACK LETTERING. AND SHALL INCLUDE THE FOLLOWING: LINE 1: FEEDER POWER SUPPLY FOR LINE 2: PANEL" "ORIGINATES LINE 3: AT PANEL' ELi 9-02 1 1 ELECTRICAL DEMOLITION GENERAL NOTES: COORDINATE DEMOLITION AND NEW WORK WITH ALL DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. PERFORM ALL WORK IN ACCORDANCE WITH THE NEC. O.S.HA. PERTINENT NFPA CODES, THE RULES AND REGULATIONS OF ALL LOCAL. STATE MID FEDERAL AUTHORITIES HAVING JURISDICTIONS, AND ALL STANDARDS APPLIED BY THE BUILDING MANAGEMENT. PROVIDE OWNER WITH CERTIFICATES OF INSPECTION. REFER TO ARCHITECTURAL DRAWINGS FOR AREAS OF DEMOLITION. EXISTING LIGHTING FIXTURES, EXIT SIGNS, AND OTHER CEILING MOUNTED DEVICES TO BE REMOVED IN THESE AREAS SHALL BE DISCONNECTED FROM ITS EXISTING SOURCE TO ALLOW FOR REMOVAL. UNLESS OTHERWISE NOTED ON ARCHITECTURAL DRAWINGS. WIRING AND CONDUIT SHALL BE REMOVED BACK TO SOURCE/PANEL. NO CONDUIT SHALL BE ABANDONED IN PLACE. 4. MISCELLANEOUS POWER DEVICES. TELECOMMUNICATION DEVICES, EXIT LIGHTS. LIGHTING FIXTURES, ETC. MOUNTED ON PARTITIONS TO BE REMOVED OR CONCEALED BY NEW CONSTRUCTION SHALL BE DISCONNECTED FROM THEIR SERVICE SOURCE TO ALLOW FOR REMOVAL. WIRING AND CONDUIT SHALL BE REMOVED BACK TO SOURCE/PANEL. NO COFAUrr SHALL BE ABANDONED IN PLACE. 5. MAINTAIN CONTINUITY OF ALL ACTIVE LIGHTING 8 POWER CIRCUITS. INTERRUPT WIRING AND REROUTE WHERE REQUIRED TO POWER EXISTING DEVICES TO REMAIN. PROVIDE AS -BUILT DRAWINGS INDICATING ALL RELOCATIONS AND CIRCUIT ADJUSTMENTS IN PANE( RMartS. UPDATE PANELBOARD CIRCUIT DIRECTORIES FOR ALL PANELBOARDS AFFECTED BY THE WORK 6. OWNER RETAINS RIGHTS OF SALVAGE FOR ELECTRICAL EQUIPMENT AND LIGHT FIXTURES TO BE REMOVED. COORDINATE WITH OWNER THE EQUIPMENT AND FIXTURES TO BE SALVAGED AND THE LOCATION FOR STORAGE. AVOID DAMAGE TO SALVAGED EQUIPMENT FIXTURES AND DEVICES DURING DEMOLITION WORK AND DURING TRANSPORT TO OWNER'S DESIGNATED STORAGE LOCATION. 7. ALL PREVIOUSLY ABANDONED OR OBSOLETE WIRING SHALL BE REMOVED IN ITS ENTIRETY. 8. REVIEW EXISTING CONDITIONS PRIOR TO DEMOLITION AND COORDINATE ANY POWER INTERRUPTIONS WITH OWNER'S REPRESENTATIVE. SEAL ALL PENETRATIONS THROUGH FLOORS. WALLS, CEILINGS, AND ROOF WHERE ELECTRICAL COMPONENTS ARE REMOVED MID WHERE THE EXISTING PENETRATION IS NOT USED FOR THE NEW INSTALLATION. REPAIR DAMAGED SURFACES TO MATCH ADJACENT AREA& 10. REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, FIXTURES, SYSTEMS. CONDUIT AND WIRING NO LONGER REQUIRED AFTER RENOVATION. SEPARATE PERMIT REQUIRED FOR: Tr MechaniCW 0 Seethe* 1!Yfmpipi C� Oe Ping City of TukWNa BUILDING DIVISION t EXPIRED NOV , '201,J REVISIONS No chances snail be made 10 Me scope .. T I HW fiuwilln. NOTE Remslons wilt e.:-::-,: .m plan MAMMA/ ,. -r. -Man renew. FILE COPY Permit No. Fl-I q - 011 1 Plan renew approval & soma IG ernrs and crn: ars AUrorove:of construct 'Ll COCti Ana does r1 autb'nze Inc violation or any mooted code Ur aralnalice Receipt of apemve° Feld Coo and ix D No BY BUILDING DIVISION RP1EVJE� FO' COMMP LI NFPA 0 A'7'0 - -•:C 'IS, a22MS Al Cry01Tukwl BUILDING DIVISION nEDFnyen CITY OF TUKV/ILA MAR 0tl 2013 PERMIT CENTER EL19•4 02.1! CallisonRTKL, Inc. The Woolworth Building 233 Broadway. lfith Floor New York, NY 10279 Tel: 212.354.9240 Fax: 212.354.9253 Calli3OnRTKL Project No: 003-160285.00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817.938.5860 ,n i.bowlero.com Consultant HENDERSON ENGINEERS 8345 LENEXA DRIVE, SUM 300 EXA, KS14 TEL (913) 7442- FAX 742.5001 WW W.HENDERSONENGINEERS.COM 1850004475 WA CORPORATE NUMBER:1754 EXPIRES 06/30/19 Amendment #1 Client/Owner/Project Address Bowlero Corporafon Client Address 22 W44111 Street, New York, NY 10036 Pro ad Address 100 Andover Park W #100, Tukwila, WA 981138 ISSUE/ Drawing Log ISSUED FOR PERMIT AMENDMENT Al 1110912MG LV012019 Sel Sheet Identification ELECTRICAL LEGEND AND GENERAL NOTES NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS 8 SITE VISITS AND MAY NOT REFLECT EXACT "AS -BUILT CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. ® 2016 CaHISmRTKL Inc E-000 O O A A Air near TX 75KVA (SUSPENDED) s. at War__y�� ///tea///re -At _///_ 4 ava afro-/ !�,, reof War ZIACZ Zee" fir+ fir- m?iiiiars /LS9� /mr,/9G1./ S Mr///// s 4_,;vs,,,.--..„ ilma_, a A /oit SA AIS nartrarsanZrwarezew i/�///yy� flflfl 4E/rAV�rrtr //4AWAI A IweiS r -�yyj���j'_p ALL EXISTING LIGHT FIXTURES, CONTROLS, AND CIRCUITING IN SHADED AREA ARE EXISTING TO REMAIN. FIELD VERIFY CIRCUIT ASSIGNMENT IN EXISTING PANELBOARD AND MAINTAIN CONTINUITY THROUGHOUT PROJECT. 4,7101.0 /5ra CIS r / ///t / /I ////1AA r/� L#� //ems -� - I//�E II I /IrAE:. i�'/_ _ _ _ / _ S --Ills/// I/s/ �, ZA r /7/ I///air' r F ra""� II/�I�II 1 I7I I /jfT�I:jrI�r'��^'-. EIWAWA!SG r.VFlE rAFaPWrrr-1 r rii . 7f1 Adi rar' i ,��y%�IIIH Ms_ Arr AreA ree�II I /�F Arre-tivr" "as arli 44.2 /rrrlAgrAgerraggra GIs: J ram A //a _ All//. war ///�� /%////,////////��/a�''/Is,'%a ai_�Soi�i�iT�•II�'��l'�iS�iLii9i?a�� %%%%%%/ V4VJJ®Z®/Y ' r�/////��/l///////////i�� I I / I ////////I%I.1 or, rAr nirraff, Frvzoirrnyfre,,, Am Or Salty ArtAly. Er Arre fraaraaaRrAt iii �� Fias���i a �� I� A / /' Aar aziviAs ArAdd irIu1 4. area A re 0 Fits 47 PNL/RIN RP### LIGHTING GENERAL NOTES: I. REFER TO SHEET E-000 FOR ADDITIONAL GENERAL NOTES. 2. REFER TO ARCHITECTS LIGHT FIXTURE PACKAGE FOR LIGHT FIXTURE INFORMATION. LIGHT FIXTURE SCHEDULE SHOWN ON SHEET E.200 IS FOR REFERENCE ONLY. 3. EMERGENCY EGRESS LIGHTING WITHIN THE ALTERATION SPACE IS EXISTING TO REMAIN. CONTRACTOR TO CONFIRM THAT MINIMUM LIGHT LEVELS OF 1.0 FOOTCANDLE AVERAGE, 0.1 FOOTCANDLE MINIMUM, AND 40/1 MAX/MIN RATIO ARE BEING MET IN CODE -REQUIRED ARF4A BY EXISTING EMERGENCY LIGHTING SCHEME. CONTRACTOR TO PROVIDE ADDITIONAL EMERGENCY LIGHTING FIXTURES TO MATCH EXISTING WHERE NECESSARY TO MEET CODE REQUIRED LIGHTING LEVELS. EXIT SIGNAGE WITHIN THE ALTERATION SPACE IS EXISTING TO REMAIN. CONTRACTOR SHALL VERIFY THAT EXISTING EXIT SIGNAGE IS IN GOOD WORKING CONDITION AND MEETS CURRENT CODE REQUIREMENTS. CONTRACTOR SHALL PROVIDE ADDITIONAL EXIT SIGNAGE TO MATCH EXISTING WHERE NECESSARY TO MEET CODE REQUIREMENTS. 5. PROVIDE NEUTRAL CONDUCTOR TO EACH WALL SWITCH LOCATION. IF NEUTRAL TERMINATION IS NOT REQUIRED. CAP CONDUCTOR AND TAG AS NEUTRAL FOR FUTURE USE. 8. LUMINAIRE SPECIFICATIONS AND LOCATIONS SHOWN ON THIS SHEET WERE PROVIDED TO HENDERSON ENGINEERS BY OWNERS LIGHTING DESIGNER. HENDERSON ENGINEERS SCOPE OF WORK FOR THE LIGHTING SYSTEM IS STRICTLY LIMITED TO CIRCUITING AND CONTROL DESIGN. THE ENGINEERS SEAL AND SIGNATURE ON THIS SHEET APPLIES ONLY TO HENDERSON ENGINEERS SCOPE OF WORK LIGHT FIXTURE TAG LEGEND L# LIGHT FIXTURE TYPE PANELBOARD AND CIRCUIT NUMBER RELAY PANEL AND RELAY NUMBER NOTE: OWNER'S LIGHTING DESIGNER. NOT HENDERSON ENGINEERS, HAS RESPONSIBILITY TO DETERMINE IF LIGHTING DESIGN MEETS MINIMUM REQUIRED EGRESS LIGHTING LEVELS. LIGHTING ORDINANCES, OTHER CODE MANOATEO LIGHTING LEVELS AHD OWNER PROJECT REQUIREMENTS. HENDERSON ENGINEERS SCOPE OF SERVICE IS TO POWER AND CONTROL LIGHTING FIXTURES ONLY. OWNER LIGHTING DESIGNER IS RESPONSIBLE FOR LIGHTING FIXTURE SELECTION AND LOCATIONS. NOTE: COORDINATE FINAL LOCATIONS. MOUNTING HEIGHTS, AND FINISHES OF ALL WIRING DEVICES WITH ARCHITECTURAL PLANS, ELEVATIONS. AND DETAILS PRIOR TO ROUGH -IN. NOTIFY ARCHITECT AND ENGINEER OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO ROUGH -IN. LIGHTING PLAN KEYED NOTES: 1. ALL EMERGENCY LIGHTING FIXTURES. CIRCUITING, AND CONTROLS IN THIS AREA ARE EXISTING TO REMAIN. FIELD VERIFY CIRCUIT ASSIGNMENT IN EXISTING PANELBOARD AND MNNTAIN CONTINUITY THROUGHOUT PROJECT. FIELD VERIFY THE EMERGENCY LIGHT FIXTURES ARE IN GOOD WORKING ORDER. REPAIR OR REPLACE IF ANY DEFICIENCIES ARE FOUND. 2. LOCATION OF EXISTING LIGHTING CONTROL TOUCHSCREEN AND LANE LIGHTING TOGGLE SWITCHES AT SHOE DESK. 3. LOCATE NEW DIMMER SWITCHES FOR ARCADE LIGHTING. AND NEW ON/OFF SWITCH FOR ARCADE GAMES AND SIGNAGE AT SHOE DESK COORDINATE FINAL LOCATION WITH ARCHITECT AND EXISTING LIGHTING CONTROL SWITCHES AND TOUCHSCREEN. SEE SHEET E-200 FOR ADDRONAL INFORMATION. 4. RELAY PANEL. REFER TO SHEETS E-200 FOR REQUIREMENTS, SCHEDULES, AND ADDITIONAL INFORMATION. 5. NOT USED 8. EXISTING LIGHTING IN THIS AREA SHALL BE REMOVED. PROTECTED, AND RETURNED TO OWNER. COORDINATE EXTENT OF REMOVAL WITH ARCHITECTURAL PLANS PRIOR TO BID. EXISTING CIRCUITING AND CONTROLS SHALL BE REMOVED BACK TO ORIGINATION POINT. EXPIRE', NOV. l 0 tots 4 RECEIVED CITY OF TUKWILA MAR 08 2019 PERMIT CENTER CALLISOIQTKL CallisanRTKL, Inc. The Woolworth Building 233 Broadway, 18th Floor New Yak, NY 10279 Tel: 212.354.9240 Fax: 212.354.9253 CalliaonRTKL Project No: 003-160285.00 Owner Bowlsro 222 W 44th St. New York, NY 10036 Tel: 817.938.5060 www.bowlero.com Consultant HENDERSON ENGINEERS 8345 LENEXA DRIVE, SUITE 383 LENEXA,KS 66214 TEL (913) 742 FA% (913) 742.5001 WWW.HENDERSONENGINEER9.COM 1850004475 WA CORPORATE NUMBER:1754 EXPIRES 06G0119 I_u 1•u Client/Owner/Project Address Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Project Address 100 Andover Pak W #100, Tukwila, WA 98188 Issue Drawing Log 11XRR1118 LIED FOR PERMIT 0E01 d119 AMENDMENT#1 Seal Sheet Identification ELECTRICAL LIGHTING PLAN ELECTRICAL LIGHTING PLAN SCALE: 1/8'=1'-0w ELi 9-02 1 1 NOTE: LIGHT FIXTURE DESIGNATICNS, LOCATIONS. AND QUANTITIES ARE FOR REFERENCE ONLY. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS, QUANTITIES, AND FIXTURE SPECIFICATIONS. PROIPTLY BRING ANY AND ALL CONFLICTS OBSERVED TO THE ATTENTION OF THE ARCHITECT AND ENGINEER PRIOR TO PURCHASE OF ANY FIXTURES OR EQUIPMENT. REFER TO LIGHT FIXTURE SCHEDULE FOR ADDITIONAL ELECTRICAL REQUIREMENTS. 02016 CNRsonRTKL Inc. E-100 RI are TX 75KVA (SUSPENDED) A//�/////// Anne rAv 9LS . rif narr-n �/r Viet --- wnr""aAgraraalair Saw iiiii�i�®®®i / ,� nr.StAr 1 Ara ..... E • sal Pyliw/% ALL EXISTING LIGHT FIXTURES. CONTROLS. AND CIRCUITING IN SHADED AREA ARE EXISTING TO REMAIN. FIELD VERIFY CIRCUIT ASSIGNMENT IN EXISTING PANELBOARD AND MAINTAIN CONTINUITY THROUGHOUT PROJECT. ELECTRICAL POWER PLAN SCALE: VB•=T-0• i'I�iZ'�i'Simi_/i�_i/ilipiratafri:14:; Fi/Res �i""sarzyge rs r Ana— a-- Al"Farndlarfra ArrAirStr ArLAISS ZS AS AS SSA reAI _S ArAr/.AS .�/COtrr Ani staa rfraerzer Aspond s__// ��/ GI!!. wen aAPS ......� � s / l I Frinew i ArirjrireArar Sin fr tram SSW SASS SSA %ira ! 1 rJ 3� iii .G0/ s/iiAV ARa/ Icn/Ii //%' � ai FI..rs .aA ialI wt ra d ir v / eerr7- ' 1 //// 1//l/li/—I.�11� irpru " r rr r S . .e . r i®/i! '/i _ �®S / ta//�.� j �I/ oriiiii�il�ii����idi� Aril "irws tWAi i iiiiiiiiiiiiii ��-- I '/5///////////////q//�/////////// "./t r r e a n m rn W i z talre seit SAttlef AI: I r"ra raw__ )A _ad tiAlr _Tar 4 ir Ald 1r Ar • • 47"Arior 'Art a- tar - MIAMI ��Aar A POWER GENERAL NOTES: 1. REFER TO SHEET E-000 FOR ADDMON.LL GENERAL NOTES. 2. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT COLOR, LOCATION AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. POWER PLAN KEYED NOTES: 1. LOCATION OF EXISTING POWER DISTRIBUTION EQUIPMENT IN MAIN ELECTRICAL ROOM. COORDINATE INSTALLATION OF NEW TRANSFORMER, PANELBOARD, RELAY PANEL, AND CONTRACTORS WITH LOCATION OF EXISTING EQUIPMENT. CONFIRM ALL CODE REQUIRED CLEARANCES ARE MAINTAINED. 2. SIGNAGE. RELOCATE EXISTING JUNCTION BOX TO NEW LOCATION OF SIGNAGE. PROVIDE LOCKABLE TOGGLE DISCONNECT SWITCH AND CONNECT NEW POWER AND CONTROLS AS INDICATED, COORDINATE FINAL LOCATION AND CONNECTION REQUIREMENTS WITH SIGN VENDOR AND ARCHITECT PRIOR TO ROUGH -IN. SIGNAGE. PROVIDE JUNCTION BOX WITH LOCKABLE TOGGLE DISCONNECT SWITCH AND CONNECT TO SIGNAGE AS REWIRED. COORDINATE FINAL LOCATION AND CONNECTION REQUIREMENTS WITH SIGN VENDOR AND ARCHITECT PRIOR TO ROUGH -IN. DEDICATED CIRCUIT FOR POS. ALL ELECTRICAL DEVICES TO BE RECESSED IN MILLWORK. ALL WIRING SHALL BE HDDEN FROM VIEW IN COUNTER. COORDINATE FINAL DEVICE LOCATION AND INSTALLATION REQUIREMENTS WITH MILLWORK CONTRACTOR AND ARCHITECT PRIOR TO ROUGH N. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 5. TELEVISION. COORDINATE FINAL LOCATION AND INSTALLATION REQUIREMENTS WM-I ARCHITECT PRIOR TO ROUGH -IN. COORDINATE TELECOMMUNICATIONS REQUIREMENTS WITH OWNER PRIOR TO ROUGH -IN. 6. SAW CUT AND TRENCH AS REQUIRED FOR ELECTRICAL AND DATA CONDUITS. REPAIR TRENCH TO MATCH SURROUNDING CONSTRUCTION, MATERIALS AND FINISHES. REFERENCE ELECTRICAL GENERAL NOTES ON SHEET E-000 FOR SPECIFICS OF UNDER FLOOR CONDUIT. COORDINATE ALL CUTTING/TRENCHING WITH OWNER AND LANDLORD REPRESENTATIVE PRIOR TO STARTING WORK. REFER TO ARCHITECTURAL DEMOLITION AND NEW WORK PLANS FOR ADDITIONAL INFORMATION. T. ALL ELECTRICAL DEVICES TO BE RECESSED N MILLWORK. ALL WRING SHALL BE HIDDEN FROM VIEW N COUNTER COORDINATE FINAL DEVICE LOCATION AND INSTALLATION REQUIREMENTS WITH ARCHITECT PRIOR TO ROUGH -IN. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. & CONTRACTOR SHALL PROTECT EXISTING ISOLATED GROUND CROWS AT SHOE DESK DURING RENOVATION AND RE -USE FOR NEW RECEPTACLES SHOWN. COORDINATE ALL REQUIREMENTS WITH EXISTING CONDITIONS, AND FINAL NEW RECEPTACLE LOCATIONS WITH ARCHITECTURAL PLANS, PRIOR TO BEGINNING WORK VERIFY THAT EXISTING CIRCUITS ARE NOT OVERLOADED WITH NEW RECEPTACLE LOAD. NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. a CONTRACTOR SHALL PROTECT EXISTING BAR TELEVISION CIRCUITS DURING RENOVATION AND RE -USE FOR NEW RECEPTACLES SHOWN. COORDINATE ALL REQUIREMENTS WITH EXISTING CONDITIONS. AND FINAL NEW RECEPTACLE LOCATIONS WITH ARCHITECTURAL PLANS. PRIOR TO BEGINNING WORK VERIFY THAT EXISTING CIRCUITS ARE NOT OVERLOADED WITH NEW RECEPTACLE LOAD. NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 10. PROVIDE FLAT CONDUCTOR CABLE (FCC)SYSTEM ROUTED UNDER CARPET TILES. PROVIDE FLUSH MOUNTED DIRECT CONNECT FLOOR RECEPTACLES AND WALL CONDUIT TRANSITION BOXES. ALL FCC SYSTEM COMPONENTS SHALL BE FROM THE SAME MANUFACTURER. PREPARE SLAB ON GRADE PER MANUFACTURER'S RECOMMENDATIONS TO PREVENT WET/DAMP LOCATION CONDITIONS. SYSTEM SHALL BE INSTALLED PER NEC ARTICLE 324 FLAT CONDUCTOR CABLES. PROVIDE TYCO ELECTRONICS UNDER -CARPET POWER SYSTEM OR APPROVED EQUIVALENT. COORDINATE EXACT LOCATION AND ROUTING WITH ARCHITECT PRIOR TO ROUGH -IN. POWER DEVICE TAG LEGEND PNLYI R1A • PANELBOARD AND CIRCUIT NUMBER RELAY PANEL AND RELAY NUMBER (IF USED) CONTACTOR NUMBER (IF USED) EXPIRED EL1 9-021 1 Nov, ).,0 2019 V ' EQF NM F P D-M MU 2 toig 1 GXy el Tukwila I. BUILDING DNINON RECFIYEi1 CRY OF TUKWILA MAR 08 2012 PEF%MIT CENTER CALLISOIQTKL CallisonRTKL, Inc. The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 Tel: 212.354.9240 FaX: 212.354.9253 CallisonRTKL Project No: 003-180285.00 Owner Bowlero 222 W 44111SL New York, NY 10036 Tel: 817.938.5860 www.bowlero.com Consultant HENDERSON ENGINEERS 8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 88214 TEL (913) 7425000 FAX (913) 74250D1 WWW.NENDERSONENGNEER&COM 1850054475 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30I19 /' 1 : CIIerNOwnar!Praject Address Bowtero Corporation Client Address 22 W441h Street, New Yolk, NY 10038 Prolect Address 100 Andover Park W 010D, Tukwila, WA 98188 Issue Drawing Log ISSUED FOR PERMS AMENDMENT Pt 11/0912018 0301/2019 Seal Sheet Identification ELECTRICAL POWER PLAN © 2016 CallisonRTKL Inc. E-110 SPACE UTI ITY TRANSFORMER CIRCUIT SCHEDULE: ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATIONS. COPPER CONDUCTORS ARE BASED ON THHNRHWN-2 INSULATION. ALUMINUM CONDUCTORS (PREFIX 'Al ARE BASED ON XHHW-2 INSULATION. FOR ANY OTHER CONDITIONS ALLOWED PER SPECIFICATIONS, OR FOR TERMINATIONS OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70. ETR c1• ❑3 MSB 480Y/277V 30 4W 1600 AMPS C 1200A 31. (ETR) 125A (3)11. (1)16G, I-1/4' C EXISTING TO REMAIN GND #2 COPPER GROUND, 3/4' C USA. (4)/4/0. (1)/2 SSBJ. (1)f2 IG, 2-I/2' C R R R R R R R R R R R R R R MAIN SWITCHBOARD 12.5EKVVA_ �A (R ) f) F_ -a n ELECTRICAL ONE -LINE DIAGRAM NOT TO SCALE ARCADE L21,1 ZONE:G 01 ARCADE ARCADE LBI DMIE SRiNGE ZONE:Al D2 WE: RI 31 ZONE: S1 a1 2 LOCATION: MAIN ELEC ROOM (EXISTING) 300A E 3P (ETR) (ETR) _ .12(( ) 0 Q 3 2 12 3P (NEW) SPACE TX (NEW) ;480Y27N, 3PH. 4W 208Y/120V, 3PH, 4W (SUSPENDED) SWITCHBANK ELEVATION GENERAL NOTES' 1. ARRANGE SWITCHES AND LOCATE UNDER COMMON COVERPLATES AS INDICATED. FIELD MODIFY ARRANGEMENT TO COMPLY WITH SPACE LIMITATIONS AND CLEARANCE REQUIREMENTS. COORDINATE FINAL LOCATION WITH ARCHITECT AND OTHER ADJACENT HVAC, SECURITY, AND AUDIO DEVICES PRIOR TO ROUGH -IN. PROVIDE FACTORY ENGRAVED FACE -PLATES AND LABELS WITH TEXT AS INDICATED ABOVE FIXTURE, PROVIDE SWITCHES WITH INDICATOR LIGHTS. ALL MASTER SWITCHES TO SERVE AS MANUAL 2-HOUR OVERRIDE. 5. REFER TO RELAY BELOW EACH SWITCH FOR LIGHTING CONTROLLED BY THAT SWITCH. REFER TO DIMMER TAG UNDER RELAY FOR DEVICE TYPE. LIGHTING CONTROL SWITCHBANK ELEVATIONS NOT TO SCALE PANELBOARD: LC1 (NEW) FED FROM: MSB VIA TX(75KVA) LINE -SIDE LUGS: MECHAMCAL BUS AMPS: 225A AC RATING: Few +10% MINMJM FULLY RATE) EQUIPMENT GROUND MWN SIZE/TYPE: 225A MOB SERVES: BOWLERO ISOLATED GROUND VOLTS/PHASE: 208Y/120V, 3PH, 4W MOUNTING SURFACE SECTION:I • LOCATION. MAIN ELECTRICAL ROOM BUS BUS CKTI DESCRIPTION VOLTAMPSIPHISE WIRE BKR P P BKR WIRE! VOL TAMPS/PHASE DESCRIPTION CKT NO A B C NO. AMP AMP NO.I A B C NO. 1 LTG -ARCADE GENERAL 1,320 12 20 1 1 20 12 100 RELAY PANEL RI' 2 3 LTG - ARCADE DECORATNE 760 12 20 1 1 20 SPARE 4 S PAR - SHOE DESK SIGN 1,000 12 20 1 1 20 SPARE 6 7 SPARE 20 1 1 20 SPARE 8 9 SPARE 20 1 1 20 10 950 PWR- ARCADE A 10 11 SPARE 20 1 I 20 10 950 PWR- ARCADEB 12 13 RCPT-TICKETMACHINE A 1,000 12 20 1 1 20 10 950 POUR- ARCADE C 14 15 RCPT- TICKET MACHINE El 1,000 12 20 1 1 20 10 950 POUR- ARCADE D 18 17 RCPT-ATM 1000 12 20 1 I 20 10 950 PWR- ARCADE E 18 19 RCPT-ARCADE CONV. 720 12 20 1 1 20 10 950 PAIR -ARCADE F 20 21 RCPT- EVENTS DESK POS 500 12 20 1 1 20 10 950 PAR -ARCADE G 22 23 SPARE 20 1 1 20 10 950 POUR -ARCADE H 24 25 RCPT-LOUNGE NA 500 . 12 20 1 I 20 10 950 POUR- ARCADE I 20 27 RCPT-LOUNGE1VB 1,000 8 20 1 1 20 10 950 PMR- ARCADE J 28 29 RCPT-CONCOURSE POS 500 10 20 1 1 20 10 - 950 POUR- ARCADE K 30 31 RCPT-VIPPOS 1000 12 20 1 1 20 10 950 PAIR -ARCADE L 32 33 SPARE 20 1 1 20 10 950 POUR- ARCADE M 34 35 SPARE 20 1 1 20 10 950 PWR-MCADEN 36 37 SPARE- 20 1 I 20 10 950 POUR -ARCADE 0 35 39 PVVR-EXIERIORSIGNAGE 1200 10 20 1 1 20 10 950 PAR - ARCADE P 40 41 POUR-ENTRY/ARCADE SIGN 1,400 8 20 1 1 20 10 950 PWR-ARCADE O 42 43 PVuR- CONC. SIGNAGE 780 12 20 1 1 20 10 950 PWR- ARCADER 44 45 POUR- EVENT/SHOE DESK SIGN 1,400 8 20 1 1 20 10 950 POUR - ARCADES 45 47 PWR - LANE SIGNAGEA 1,248 8 20 I 1 20 10 950 POUR -ARCADET 48 49 POUR - LANESIGNAGEB 1,248 8 20 I 1 20 10 950 POUR- ARCADE U 50 51 PURR- LANE SIGNA(,EC 1,248 6 20 1 1 20 10 950 POUR- ARCADE V 52 53 POUR - LANESIGNAGED 1248 6 20 1 1 20 10 950 PWR- ARCADE W 54 55 PWR-LANE SIGNAGE E 1,248 6 20 1 1 20 10 950 PWR-ARCADEX 50 57 PAR- LANE SIGNAGE F 1.248 4 20 1 1 20 10 950 PAR -ARCADE Y 58 59 POUR- LANE SIGNAGE G 1248 4 20 1 1 20 10 950 POUR- ARCADE Z 60 61 PAR- LANE SIGNAGE H 1,248 1 4 20 1 1 20 10 950 PWR- ARCADE M 02 63 PAR -LANE SIGNAGE I 1,248 4 20 1 1 20 10 950 POUR -ARCADE AB 54 65 PAR - LANE SIGNAGE J 1240 4 20 1 1 20 10 950 PWR-ARCADE AC 68 67 SPARE 20 1 1 20 SPARE 68 69 SPARE 20 1 1 20 SPARE 70 71 SPARE 20 1 1 20 SPARE 72 SUBTOTAL 9,064 9,604 8,892 8,650 9,500 9,500 SUBTOTAL TOTAL PHASEA VA 17714 LOAD CONN. VA DF LOAD CONN. VA OF MPS 148 CORING 1.00 HE IG 1.00 TOTAL PHASE B-VA 19,104 HEATING 0 SIGNIDISP 18,260 1.25 MPS 159 LIGHTING 2,080 125 KITCHEN 1.00 TOTAL PHASE C-VA 18,392 RECEPTACLES 720 1.0/.5 EMS fWG 1.00 AMPS 153 MOTORS 1.00 LRG MOTOR 1.25 TOTAL DEMAND TOTAL PNLBD-VA 55,210 SUPP HEAT 1.00 SHOWWNDW 1,25 60.295 VA MPS 153 MSC EQUIP 34,150 1.00 LTG TRACK 1.00 167A PANELBOARD NOTES RP RELAY PANEL IG- ISOLATED GROUND CIRCUIT SINGLE SECTION PANELBOARD -VIA SIGN/DISPLAY-SIGNPQE S DISPLAVCASE 2P 2P 2P iP iP 2P RP iP 2P 2P iP RP 2P RP 2P 2P 2P RP RP RP RP RP RP RP RP RP RP RP GENERAL ONE -LINE NOTES: 1. INFORMATION SHOWN ON DRAWINGS IS INTENDED TO INDICATE MINIMUM REQUIREMENTS TO MEET THE NEEDS OF THE OWNER. VERIFY EXISTING CONDITIONS. CAPACITIES, MID OTHER PROVISIONS BY OTHERS PER BUILDING/TENANT LEASE AGREEMENT PRIOR TO BEGINNING CONSTRUCTION. 2, ALL CONDUCTOR LENGTHS PROVIDED IN THESE DESIGN DOCUMENTS ARE INTENDED SOLELY FOR USE IN THE DESIGN CALCULATIONS BY THE DESIGN PROFESSIONAL UNLESS SPECIFICALLY NOTED OTHERWISE IN THE DOCUMENTS. THEY SHALL NOT BE USED BY CONTRACTORS IN BIDDING OR CONSTRUCTING THE PROJECT. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MATERIAL QUANTITIES REQUIRED TO BID AND CONSTRUCT THE COMPLETE PROJECT. 3. PROVIDE COMPLETE TYPEWRITTEN IDENTIFICATION DIRECTORY CARD FOR ALL MAIN AND BRANCH CIRCUITS IN THE PANELBOARD DOORS. 4. ALL NEW WORK SHALL BE COORDINATED WITH LANDLORD AND SHALL BE IN ACCORDANCE WITH LANDLORD'S REQUIREMENTS. 5. THE USE OF 'BX, ROMEX', OR 'AC' IS NOT PERMITTED. 6. 'F# REPRESENTS FAULT POINT FP AS CALCULATED IN TABLE BELOW. 7. V IN FEEDER TAG INDICATES FEEDER SIZES HAVE BEEN INCREASED FOR VOLTAGE DROP. REFER TO CIRCUIT SCHEDULE FOR FEEDER SIZES. B. CONTRACTOR SHALL PROVIDE AND INSTALL A LABEL ON THE FIRST PIECE OF SERVICE EQUIPMENT INDICATING THE AVAILABLE FAULT CURRENT AT THE EQUIPMENT. LABEL SHALL BE CUSTOM DIGITALLY PRINTED AND HIGH -DURABILITY LAMINATED LABEL RATED FOR OUTDOOR APPLICATIONS. LETTERING SHALL BE A MINIMUM OF 1/4" HIGH YELLOW BACKGROUND WITH BLACK LETTERING. AND SHALL INCLUDE INFORMATION AS INDICATED IN LABEL #1 BELOW. 9. CONTRACTOR SHALL PROVIDE MID INSTALL A LABEL ON ALL SWITCHBOARDS MID PANELBOARDS INDICATING WHERE THE EQUIPMENT IS FED FROM. LABEL SHALL BE CUSTOM DIGITALLY PRINTED AND HIGH -DURABILITY LAMINATED LABEL RATED FOR OUTDOOR APPLICATIONS. LETTERING SHALL BE A MINIMUM OF 1/4- HIGH YELLOW BACKGROUND WITH BLACK LETTERING. AND SHALL INCLUDE INFORMATION AS INDICATED IN LABEL #2 BELOW. 10. CONTRACTOR SHALL PROVIDE AND INSTALL A LABEL ON ALL TRANSFORMERS INDICATING WHERE THE TRANSFORMER IS FED FROM AND THE LOCATION OF THE PRIMARY DISCONNECTING MEANS. LABEL SHALL BE CUSTOM DIGITALLY PRINTED AND HIGH -DURABILITY LAMINATED LABEL RATED FOR OUTDOOR APPLICATIONS. LETTERING SHALL BE A MINIMUM OF 1/4-HIGH YELLOW BACKGROUND WITH BLACK LETTERING, AND SHALL INCLUDE INFORMATION AS INDICATED IN LABEL 113 BFI OW. ❑ ONE -LINE DIAGRAM KEYED NOTES: 1. EXISTING UTILITY METER INSTALLED IN METER SOCKET TO REMAIN. COORDINATE EXACT REQUIREMENTS WITH LANDLORD AND UTILITY COMPANY. 2. CONTRACTOR TO CONFIRM THIS IS POINT OF SERVICE ENTRANCE MID THAT NEUTRAL AND GROUND ARE BONDED TOGETHER AND TO THE GROUNDING ELECTRODE SYSTEM. REPORT ANY DISCREPANCIES TO THE ENGINEER. I PRIOR TO CONNECTING NEW LOADS. CONNECT A RECORDING METER TO THE EXISTING 1200 AMP FEEDER FOR A PERIOD OF 30 DAYS AND REPORT PEAK DEMAND (kW) WITH TIME AND DATE TO ENGINEER IF THE PEAK LOAD MEASURED DURING THIS TIME PERIOD IS GREATER THAN 600kW, DO NOT PROCEED WITH CONSTRUCTION AND IMMEDIATELY CONTACT THE ENGINEER AND PROVIDE THE FOLLOWING DATA PEAK DEMAND (kW) TIME AND DATE PEAK DEMAND OCCURRED 4. ADD NEW CIRCUIT BREAKER DISCONNECT IN EXISTING SERVICE ENTRANCE MAIN SWITCHBOARD. COORDINATE REQUIREMENTS WITH MANUFACTURE CONFIRM ALL RATINGS OF NEW CIRCUIT BREAKER MATCH THAT OF THE EXISTING EQUIPMENT. SWITCHBANK ELEVATION KEYED NOTES: E GANG SWITCHES TOGETHER UNDER COMMON COVERPLATE AS INDICATED. E COORDINATE STYLE OF DIMMING WITH FIXTURE AND SWITCH MANUFACTURERS PRIOR TO PURCHASE. VERIFY DERATED CAPACITY OF DIMMER SWITCH CAN HANDLE WATTAGE LOAD, PROVIDE PERMANENT LABELS FOR DIMMER NUMBER AND LOAD CONTROLLED FOR EACH SWITCH. BUILDING ELECTRICAL SERVICE LOAD SUMMARY BUILDING OCCUPANCY TYPE: A BUILDING SQUARE FOOTAGE: 506106 SERVICE DESCRIPTION. 480Y/277V, 3PH LOAD DESCRIPTION Connected KVA Demand FACTOR Demand KVA `EXISTING LOAD ON 'MSS' N/A 100% 798.00 HVAC- SUMMER(ETR) 0.00 100% 0.00 HVAC-WINTER (ETR) 0.00 100% 0.00 LIGHTING (PER NEC-220) 2.08 125% 2.60 RECEPTACLES 0.7210096;5096 0.72 MISCELLANEOUS EQUIPMENT 34.15 100% 34.15 DISPLAY CASE/SIGNAGE 18.26 125% 22.83 EXSTING LOAD TO BE DELETED 0.00 100% 0.00 55.21 KVA 858.30 TOTAL LOAD TOTAL AMPACITY 66.41 AMPS 1032.3 1200 AMPS 1200.00 SERVICE AMPACEN SPARE CAPACITY AMPS 168 `80% OF MAIN SWITCHBOARD MSB' RATED CAPACITY 798 KW ELECTRICAL DISTRIBUTION EQUIPMENT IS EXISTING TO REMAIN, UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW FEEDER BREAKERSARE REQUIRED TO MATCH THE EXISTING AIC RATING OF THE DISTRIBUTION PANELBOARD IN WHICH IT IS INSTALLED, OR TO EXCEED THE CALCULATED FAULT CURRENT BYA MINIMUM OF 10%, WHICH EVER VALUE IS GREATER LABEL #1: SERVICE DISCONNECT VOLTAGE AND HERTZ] (EQUIPMENT BUS RATING] SHORT-CIRCUIT CURRENT RATING (SCCR): (EQUIPMENT RATING) MAXIMUM AVAILABLE FAULT CURRENT: (FCAI DATE CALCULATED: (MMIDD/YYYY] LABEL #2 LABEL#3: DEDICATED CIRCUIT FOR RELAY PANEL POWER I POWER PANEL FEEDER POWER SUPPLY FOR PANEL NAME(ORIGINATES AT PANELJNAMEI. FEEDER POWER SUPPLY FOR TRANSFORMER NAME ORIGINATES IN PANELBOARD NAME'. CIRCUIT NUMBER NUMBER] LOCATED IN (ROOM NAME]. RELAY PANEL RP E S BRANCH CIRCUITS PER PANEL SCHEDULES (TYPICAL U.N O.) DIMMABLE FIXTURES SWITCHED LOADS AND FIXTURES ARCADE GAMES AND SIGNAGE LIGHTING CONTROL DIAGRAM IS DIAGRAMMATIC AND REPRESENTS THE GENERAL SCOPE OF WORK MID THE LOCATION OF DEVICES IN RELATION TO EACH OTHER ALONG THE POWER CIRCUIT. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MANUFACTURER FOR INSTALLATION INFORMATION. PROVIDE ALL PARTS AND PIECES REQUIRED FOR A FULLY FUNCTIONAL SYSTEM. LIGHTING CONTROL DIAGRAM NOT TO SCALE UTILITY COMPANY: PUGEf SOUND ENERGY CALCULATION BASED ON AN AVAILABLE FAULT CURRENT OF 64,000 AMPS AT THE SERVICE ENTRANCE MAIN SWITCHBOARD'MSB' PER BASE BUILDING DRAWINGS DATED 05.23.05 PROVIDED TO HENDERSON ENGINEERS IN THE DESIGN PROCESS. CONTRACTOR SHALL FIELD VERIFY EXISTING AVAILABLE FAULT CURRENT AT THE LOCATION INDICATED AND REPORT FINDINGS TO ENGINEER. Short -Circuit and Voltage Distances are for calculation purposes only and shall The following calculations are based on the "Point-byPolnr ISC r4= SCo, xMrn ISC m= short circuit current at fault point l ISC ,a= short circuit current atfault point 2 IP= Primary short circuit current W = PdmarywItage IS= Secondary shod circuit current VsR= L• Length Secondary L• Length of circuit C ='C Factor from Buss man table where Feeder Types= NM- Non Magnetic Conduit. M- Magnetic Conduit, not be used for wntraclor Drop Calculations takeoffs nor bidding -Contactor shall flatly where: Feeder: fry,= Feeder fae• to line volts per linear root Busway, PB - Plug-in Busway. TX -Transformer Engineer of any 1.732xLxlsc field condition that results in a Change )iFMR: fNo= *MR: foe= o110% or greater circuit distance IP(sca)xW x1.73 x%2 IS_)= W xM KIP, VOLTAGE DROP (30): %VD= ((Rxwe(arcws(pg) +Xxsln (ar VOLTAGE DROP (10): %VD= ((R xcos(arowa(pg)+ Xx sin(amoos(p0)) %VD OWN CumulaBLe Voltage Drop resistance in ohms per X= reactances in ohms per s(pg)) horn Fault LF LF x Lift xlx1.73)/E x2 MAT xl)/E Point 1 to Fault Point# method M= 1/(1,1) E•Line 'C'=1 /Impedance FB Feeder C xE 2 AL xlsc 100,000 x KVA F(sca)xVp x%Z Vs CxE 100,000x KVA Fault Point (F9) BusFeeder Description Source (Fault Point) Phase Source Mc (amps) Feeder Condo r C'VBlue Buswayt' Value(E) L-L Voltage Circuit Length (L) Load Power Factor CO Clrwll Load (AInparage) Conducbr Transformer f M Fault Current (amps) Voltage Drop (%VD) CumuleSe Voltage Drop (MC) Fault Point Mt) Resistance (R) Reactance N Prccos(i) Type Degree Rise WA New XfinrZ ENetizg AmrZ Secondary Voltage Tap Selling Conduit Type/TX Material Quantih of Parallel Sets and Bus/ Phase & Neutral SIN (Radians) SerNce Point 64,000 at to Ana t meted g switchboard Source Hc+ 6X Motor Conbibution• 64000 1 1 UBliy Contibudon The connected MI load motor amps (includes compressors) on the system A Attar TO TRANSFORMER TX 1 3 64000 M CU 1 Set(s) of I AWG 7293 - 480 40 0.9 90 0.000160 0.000057 0.451027 1.267 044 28236 -022% -0.22% 2 2 TRANSFORMER 'TX 2 3 28236 TX 480 DOE 150 75 3.61 208 11.299 0.08 5298 -0.22% 3 3 4 TOPMELBOARD 'LCY 3 3 5298 M CU 1 Segs) of 410 AAG 15082 - 480 10 0.9 180 0.000083 0.000051 0.451027 0.013 0,99 5232 -0.05% -0.27% 4 REFERENCE LIGHTING FIXTURE SCHEDULE NOTE: REFER TO ARCHITECTURAL AND LIGHTING CONSULTANT PLANS AND SPECIFICATIONS FOR FIXTURE CATALOG NUMBERS. ACCESSORIES. FINISHES, MOUNTING, LAMP BEAM SPREAD. AND OTHER INFORMATION. TAG DESCRIPTION LAMPS BALLAST/ DRIVER INPUT WATTS INPUT VA - VOLTAGE DINNING TYPE NOTES NO. TYPE L9.1 JELLYJAR PENDANT 1 SOWING - 60 60 120 INC FIXTURE SHALL BE PROVIDEDWT-IFACTORY INSTALLED.W0MUM WATTAGE LABEL: 'MAXIMUM 60 WATT' L21.1 4' SUSPENDED LINEAR FLUORESCENT 1 F28T5 ELECTRONIC 30 34 120277 0-10y GEE RAL NOTES: A REFER TO ARCHITECTURAL DRAWINGS AND DETAILS FOR MODEL NUMBERS, EXACT LOCATIONS, MOUNTING HEIGHTS AND ADDITIONAL MOUNTING INFORMATION. CONTACT ARCHITECT IM.EDLATELY IF THERE ARE DISCREPANC ES BETWEEN THE ARCHITECTURAL AND ELECTRICAL LIGHTING PLANS. B. REFER TO OMSION 16 SPECIFICATIONS FOR ACCEPTABLE LAP AND BALLAST MANUFACTURERS AND ADDITIONAL INFORMATION. C. SEASON ( BURN IN) DIMMED FLUORESCENT LAMPS AT FULL LIGHT OUTPUT FOR 12 CONTINUOUS HOURS PRIOR TO DINNING. D. REFER TO LIGHTING DIMING RELAY PANEL SCHEDULE AND PANELBOARD SCHEDULES FOR CONTROL INFORMATION. SUPPORT SYSTEM SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER INSTALL TRANSFORMER ABOVE AND IN FRONT OF ELECTRICAL PANELBOARD MINIMUM DISTANCE item PANELBOARD WORKING SPACE CLEARANCE AS REQUIRED BY NEC LIGHTING CONTROL DEVICE SCHEDULE WALL SWITCHES SYMBOL TYPE MANUFACTURER MODELISERES EQUIVALENT MANUFACTURER DEVICE DESCRIPTION VOLTAGE NOTES i LUTRON VAREO LEMON LEGRAND SINGLE BUTTON ON/OFF SWITCH FOR CONTROL OF ARCADE GANESVA RELAY PANEL. SHALL BE COPATIBLE WITH RELAY PANEL. 120V 277V WALL DIMMINGSWITDHES SYMBOL TYPE MANUFACTURER MO0EJSER S EQUIVALENT MANUFACTURER DEVICE DESCRIPTION LOAD TYPE WATTAGE VOLTAGE NOTES g' LUTRON NOVAT NT1000 LEVTTON LEGRAND LINE VOLTAGE SLIDER -TYPE WALL BOXDINEER FOR MANUAL ON/OFF AND DIMNNGCONTROL. LOCATE DOWNSTREAM OF RELAY PANEL. INC 1000 120V 277V LUTRON NOVAT NTS1V-DV LENTON LEGRAND 0-10V LOW VOLTAGE SLIDER -TYPE DETER SINK TO 30mAVATH INTEGRAL MANUAL ON/OFF PADDLE STYLE SWITCH. 0-10V 960 120V 27N GENERAL NOTES: A OCCUPANCY SENSOR MANUFACTURER -SPECIFIC B AYWUFACTUNERS CONSIDERED CUTSHEETS AND SHOP C SHOP DRAWINGS FOR SCHEMATICS AND SCHEDULES. CONSTRAINTS, D OCCUPANCY SENSOR SENSOR. ALSO INCLUDE RETURN GRILLES. SPRINKLERS, E PROVIDE ALL OCCUPANCY F VERIFY COLOR(S) FOR G PROVDE COPIES OF OPERATK)N H ALL WALL SWATCH MID I DO NOT INSTALL LINE J LIGHTING CONTROLS PRICING (UNIT OR MNI-LOT) K INSTALL WALL BOXDIM,ERS L CONTRACTOR SHALL M PROVIDEA NEUTRAL CONDUCTOR SCHEDULED NOTES: 1. MONENTAPY SNITCH LAYOUT BASED ON WATTSTOPPER COVERAGE PATTERNS. ADJUST QUANTITIES AND LOCATIONS FOR EQUIVALENTM ANUFACTURERS SPACING CRITERIA EWNALENT FOR SUBMSSION ARE LISTED INEQUIVALENT MNUFACTURER COLUMN IN SCHEDULE. DURING LISTED BELOW PER SUBMTTALS, PROVIDE PRODUCT SPECIFIC LKNTNO CONTROL WITHIN PROJECT SPACE AREAS FOR EACH OCCUPANCY LOTTED TO HVAC SUPPLY AND SUBMITTED Will LIGHTFIXNRE TO OPERATE TOGETHER. DRAWINGS (AS FURTHER LIGHTING CONTROL ALSO, AT ENGINEER'S SHOP DRAWINGS SHALL ON PLANS OTHER AND LIGHT SENSORS BYTHE ALL WALL AND CEILING INSTRUCTIONS CEILING SENSORS SHALL VOLTAGE SENSORS ON PRICING SHALL BE COMPLETELY WILL BE INNEDIATELY TOACHIEVE FULL BE RESPONSIBLE FOR DEFINED IN GENERAL NOTES Or THIS SCHEDULE) FOR ENGINEERS RENEW DEVICES THATAPE INTENDED FOR USE AS ALIGHTING CONTROL SYSTEM SHALL INCLUDE PROJECT REQUEST, PROVIDE ASCALED EQUIPMENT PLAN FOR REVIEW OF EQUIPMENT LOCATIONS INCLUDE LIGHTING PLANS SHOWING LOCATION, MOUNTING HEIGHT, ORIENTATION AND COVERAGE CEILING MOUNTED SYSTEMS. SHOVING COORDINATION WITH CEILING DEVICES INCLUDING BUT NOT FIXTURES. SAME MANUFACTURER. MOUNTED LIGHTING CONTROL DEUCES WITH THE ARCHITECT. FOR ALL DEVICES TO OWNER. HAVE AN ADJUSTABLE TINE DELAYRANGE OF 0-30 MN, UNO. GFCI PROTECTED CIRCUITS. SEPARATE OF ANY LIGHT FIXTURE PRICING. ANY LIGHTING CONTROLS PRICING THAT IS REJECTED IN ITS ENTRETY. RATING SPECIFIED AND INDICATED AFTER DE -RATING FOR GANGING PS INSTRUCTED BY MANUFACTURER. ENSURING COMPATIBILITY OF ALL LIGHTING CONTROL DEVICES IN THIS SCHEDULE THAT ARE INTENDED BOX DRAPERS. DO NOT SHARE NEUTRAL CONDUCTOR ON LOAD SEE OF WMMER. VURH ITS CONNECTED LIGHTNG CONTROL DEVICE (I.E. OCCUPANCY SENSOR, RELAY PANEL, ETC.) TO ALL WALL SHALL BE COMPATIBLE LIGHTING CONTROL DIAGRAM GENERAL NOTES: 1. LIGHTING CONTROL DIAGRAM IS DIAGRAMMATIC AND REPRESENTS THE GENERAL SCOPE OF WORK AND THE LOCATION OF DEVICES IN RELATION TO EACH OTHER ALONG THE POWER CIRCUIT. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH SELECTED MANUFACTURER PROVIDE AL PARTS AND PIECES REQUIRED FOR A FULLY FUNCTIONAL SYSTEM. LIGHTING CONTROL SYSTEM INCLUDING. BUT NOT LIMITED TO INTEGRAL TIME CLOCK, RELAYS, AND DIGITAL LIGHTING CONTROL SWITCHES SUPPLIED BY LIGHTING VENDOR 3. LIGHTING VENDOR SNAIL BE RESPONSIBLE FOR CONFIRMING COMPATIBILITY OF ALL LIGHTING CONTROL DEVICES AND DIMMING SWITCHES WITH LIGHT FIXTURES. 4. INTEGRAL TIME CLOCK SHALL BE ASTRONOMIC AND PROGRAMMABLE WITH 365 DAY AND HOLIDAY SCHEDULING AND 24 HOUR BATTERY BACK-UP. RELAYS SHALL BE MECHANICALLY HELD, SINGLE POLE. 20A RATED, NORMALLY CLOSED CONTACTS. LIGHTING CONTROL SYSTEM SHALL COMPLY WITH ALL LOCAL AND STATE ENERGY CODES. 5. CIRCUITING SHOWN ON THE PLAN CORRESPONDS TO THE LIGHTING CONTROL SCHEME. IF CIRCUITING IS CHANGED IN THE FIELD. ENSURE THAT SYSTEM PROGRAMMING WITH REVISED CIRCUITING MEETS THE ORIGINAL LIGHTING CONTROL SCHEME. UPDATE RELAY PANEL SCHEDULES IN RECORD DRAWINGS 6. COORDINATE WITH OWNER AND LANDLORD FOR PROGRAMMABLE TIME CLOCK SCHEDULES. CONTRACTOR TO PROVIDE TRAINING OF LIGHTING CONTROL SYSTEM AND OPERATIONS MANUAL TO THE STORE MANAGER AFTER JOB IS COMPLETE. A COPY OF THE RECORD DRAWINGS AND RELAY SCHEDULE WITH ANY FIELD CONDITION CHANGES IDENTIFIED SHALL BE LEFT IN THE DOOR OF THE PANEL ❑ LIGHTING CONTROL DIAGRAM KEYED NOTES: 1. STAND-ALONE LIGHTING CONTROL RELAY PANEL INFORMATION: e. MANUFACTURER: ICED #GR1408-LT-INTNCL-DTCMOD-DV AND INTEGRAL TIME CLOCK b. ENCLOSURE: SURFACE MOUNT #GR140B-LT-ENCSM-NEI, NEMA 1 c. INTEGRAL TIME CLOCK: REFER TO CASS AND RELAY PANEL SCHEDULES ON THIS SHEET FOR TIME CLOCK AND RELAY PROGRAMMING. 2. DIMMING LIGHTING CONTROL SWITCH. REFER TO LIGHTING CONTROL DEVICE SCHEDULE AND TO LIGHTING PLAN FOR ADDITIONAL INFORMATION. 3, PROVIDE ALARM INPUT FROM SECURITY. COORDINATE ALL REQUIREMENTS WITH SECURITY CONTRACTOR. 4. PROVIDE CONNECTION TO DEDICATED TELEPHONE OUTLET FOR CONNECT TO MANUFACTURER PROVIDED REMOTE PROGRAMMING SERVICE. COORDINATE CONNECTION TO OWNERS TELEPHONE SERVICE WITH OWNER 5. NOT USED. 8. ON/OFF SWITCH FOR CONTROL OF ARCADE LOADS. REFER TO LIGHTING CONTROL DEVICE SCHEDULE AND TO LIGHTING PLAN FOR ADDITIONAL INFORMATION. CASS: CLOCK AUTOMATION (GLOBAL CONTROL OF ALL RELAYPMELS) SCENARIOS SCHEDULE ZONE DESCRIPTION AUTOMATION SCENARIO SCHEDULE ON/OFF MANUAL ON/ SCHEDULE OFF ASTRONOMIC ON/OFF I MANUAL ON/OFF Al ACCENT LIGHTING X G1 GENERAL LIGHTING X RI ARCADE CONTROLLED RECEPTACLES X SI INTERIOR SIGNAGE X SXI EXTERIOR SIGNAGE X SECURITY AND FIRE ALARM INPUT RECEIVES INPUT FROM SECURITY SYSTEM TO TJRN ALL LIGHTS ON TYPICAL SCHEDULE: ^ CONFIRM FINAL TIME SCHEDULE FROM OWNER PRIOR TO SYSTEM PROGRANING OCCUPIED HOURS: MON-FRI: 12:00 PM-1 00 AM SATURDAY: 11'00 AM-2D0 AM SUNDAY: 9:30 AM- 1200 AM FLICK WARN 5 MNUTES-2 HOUR OVERRIDE ELi 9-02 1 1 DEDICATED ELECTRICAL SPACE. EXTENDS TO 6' ABOVE PANEL BOARD OR TO STRUCTURAL CEILING, WHICHEVER IS LOWER. LOCATE TRANSFORMER 5" MINIMUM FROM ALL WALLS. MAXIMUM OF 10 SECONDARY CONDUCTOR LENGTH. FLEXIBLE CONDUIT RIGID CONDUIT ELECTRICAL PANELBOARD SUPPLIED BY TRANSFORMER DEDICATED ELECTRICAL SPACE (BOTTOM OF PANELBOARD TO FLOOR) FLOOR SUSPENDED ()TRANSFORMER MOUNTING DETAIL NO SCALE UTILITY TRANSFORMER SERVICE ENTRANCE CONDUCTORS SERVICE ENTRANCE PANELBOARD 0 C' tTh CONDUIT BONDING JUMPER RELAY PANEL SCHEDULE PANEL MANE: RI LOCATION: RELAY CIRCUIT LOAD CONTROLLED ZONE 1 LC1-I LTG -ARCADE GENERAL G1 2 LCI-3 LTG- ARCADE DECORATIVE Al 3 LC15 PAR -SHOE DESK SIGN S1 4 LC139 PAR- EXTERIOR SIGNAGE SX1 5 LC141 PAR - ENTRY/ARCADE SIGN Si 6 LC143 PAR - CONC. SIGNAGE SI 7 LC145 PVUR- EVENT/SHOE DESK SIGN Si 8 LC147 PAR - LONE SIGNAGE A SI 9 LC149 PAR - LANE SIGNAGE B SI 10 LCI51 PAR - LANE SIGNPGEC SI 11 LC153 POUR - LANESIGNAGED S1 12 LC1-55 PAR - LANE SIGNAGE E SI 13 LC157 PAR -LANE NONAGE SI 14 LC1-59 POUR- LANE SIGNAGE G SI IS LC1-81 PAR -LANE SIGNAGE H SI 16 LC1-63 PVUR- LANE SIGNAGE I SI 17 LCI-65 PWR- LANE SIGNAGE J SI 18 LC1-10 POUR -ARCADE A RI 19 LC1-12 PAR -ARCADE B RI 20 LC1-14 PVMR-ARCFDEC RI 21 LC1-16 PAR - ARCADE D RI 22 LC1-18 PAR -ARCADE E RI 23 LC1-20 PAR - ARCADE F RI 24 LC1-22 PAR -ARCADEG RI 25 LC1-24 PAR - ARCADE H RI 29 LC1-26 PAR - ARCADE I RI 27 LC1-28 PAR - ARCADE J RI 28 LCI-30 FAR - ARCADE K RI 29 LC132 PAR - ARCADE L RI 30 LC134 PAR - ARCADE M RI 31 LCI-36 PAR - ARCADE N R1 32 LC138 PAR - ARCADE O RI 33 LC140 PAR-ARCADEP RI 34 LC142 PAR - ARCADE O R1 35 LC144 PAR-ARCADER R1 36 LC146 PAR -ARCADES RI 37 LC148 POUR- ARCADE T RI 38 LC1-50 PAR - ARCADE U RI 39 LC152 MAR - ARCADE V RI 40 LC154 PWR-ARCADE W RI 41 LC156 PM -ARCADE % RI 42 LC158 PURR - ARCADE Y RI 43 LC1-60 POUR -ARCADE Z RI 44 LCI-62 PWR-ARCADE AA RI 45 LC1-64 PAR - ARCADE AB RI 46 LC1.66 PAR -ARCADE AC R1 47 SPACE 48 SPACE EXPIRED POWER FEEDER SEPARATELY DERIVED SOURCE CONDUIT BONDING JUMPER SERVICE ENTRANCE LOCAL GROUNDING ELECTRODES GROUNDING ELECTRODE NOV. u 2019 DERIVED CIRCUIT IG BRANCH PANELBOARD /\ r• ;. r. AM M ST CONDUIT BONDING JUMPER MAIN BONDING JUMPER BRANCH CIRCUIT ISOLATED GROUND RECEPTACLE N IG G 4 4 CONDUIT BONDING JUMPER rIr-Piyr TIC: F'JH �.,. N PAO-YNB+NC City of Tukwila ILDING DIVISION FLEX CORD AND PLUG SENSITIVE LOAD RECEIVED CITY OF T UKWILA MAR 08 ZI)19 ISOLATED CONDUCTOR WIRING WITH PERMIT CENTER SEPARATELY DERIVED SOURCE DETAIL NO SCALE CALLISOIQT CalliSonRTKL, Inc. The Wodworth Building 233 Broadway, 16th Floor New Yolk, NY 10279 Tel: 212.354.9240 Fax 212 354 9253 CallisonRTKL Project No: 003-160285.00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817.938.5660 www.bowlero.com Consultant isseor HENDERSON ENGINEERS 8345 LENEXA DRNE, SUITE300 LENEXA KS 66214 TEL (913) 7425000 FAX (913) 7425001 WYM..NENDERSONENGNEERSCOM 1850004475 WA CORPORATE NUMBER:1754 EXPIRES 08/30/19 Ct z I- 0 a) 0 CO Client/Owner/Project Address A.� t C p Bowlero Corporation Client Address 22 W44N Street, New York, NY 10036 Project Address 100 Andover Park W #100, Tukwila, WA 96188 Issue Drawing Log ISSUED FOR PERMIT AMENDMENT81 11D&2010 03/012319 Seal Sheet Identification ELECTRICAL ONE -LINE, SCHEDULES, AND DETAILS E-200 J 2016 CallisonRTKL Inc. CALLISOIQTKL CaIlIsonRTKL, Inc. Lighting Summary LTG -SUM EnergyCode Compliance Fomabr Cwm,rdel the sldudllg m, R3, R4Ovet 3 stories and Y RI Revised Nsv2017 2015 WasNrymn Stale Project Info Cempaince do nod requite• Project Slue: Bowie Tukia Dale 11/14/2018 respond %M,akvL Rat mama irabmelion bimaidel Wes on ApptlmMforms quires about emplanes ones form Mbm.Sar pawed Fa Building OpMM aMUse Company Nemm: Password I snse rev and cekublrq colts are AM- protaMd CanpanY Address: PryeGnt Hone: •O&n( Rene: Afplkant Suet Project Description 0taw adding 0 Addition la Alteration 0 No Lighting Scope Mdjde PRO -SUM tam (included M antelope ,bins '*boo )who ka41g rowlance hone. Interim Lighting System Description order LgMn9 pins Ncatled Ragacemem of nogg in Arcade area, Power Space -by -space Method Interior Lighting Allowance Method 0 Bulling Area Midas O sera mated Used In project. Interim Lighting Controls ON C405.2.1- G05.18 L'gMlg Controls 0 CA05.2 Eaplbn 5 Lunlreke Level Ltyrdy Controls Onc) 0 Additional ERnGpinn U06 a Enhanced Digital Lghang Controls To comply fin 090e,4, no Mnthn 90%or the total Mazda/ Mader lighting poner shell meWj MT Me requ✓ed mmrob perC4c8,4, Dwelling Unit Interior Lighting pemenenlY Mssued lnmrror/ghrng Metres M dwasng units con* WM: • No Dyeemg 004052 thoum C405.5 CuerdM Lighting Controls and LPA Units 0 U063 t(]h Efficacy Lighting 0 R4041 Wlldnllel Mph Efficacy Lighting, peeling use Nphmg comFaes who WSEC Read iWl pews os M Neu of WSEC Camera& pmaioa Exterior Lighting Description System h GNded MA 0 Reg Lffillting Building Additions Wert SedM C50226 W ad/MOAN ree0e ena_ Compliance Method Lightig s logs as m dSo mnMrw applicable seNM alone wnWum pled __ Lighting gams in addition are conned WM Wtlng Miming lgm htig swears to demonstrate rpence MeaSpAiy I Edefa1geMg CI T 0 _ -_l._ 0 I 0 1 Wader lWMrg Rama wattage in tare egeder Adding litre ROMP en AJNbn le am*M.d with elleSlnp For Marla lghap peg eels, include new aaysing 0-ramafi Proposed Lighting Weflpetable M LTG INTdD a LTG-INT-SPACE Fa *fleet( *IMO anima. include new. a elig4A'aeln Proposed Tradable end Proposed 6.6mTradWe Lghlne Wattage MOOS M LTGIXT Wm Lighting, Motor, and Electrical Permit Checklist, Pg. 2 L - e e and al RI RMNO Nov 2017 2016. Washington State Enemy Code Compliance Forms W COrWnerdS B rising Gudng R2. R3. R4 over 3 stales Project lie BwleroTukWs Date 11/14/2010 The ktrawl rg inkimSlags the neceelay to Mack perm fplmioo for comp nor wild the lighting. mdpr, and eleGCS rw regents1 Applicability (yeano.na) Code Section tampon's* Compliance information required in permit document Location In Documents Bathing Department Note C4ro26- Item IYxWmkel siren roans indicate method of automatic control - vecontrol - vacancy Or COtis'6 key control of at installed luminaires and d f :Mlbces In guest roan m G06.25 Item Supplemental task lifting method and location of automatic shut-off vacancy controlfor supplementaltask lighng. including under -shelf or under -cabinet lighting NA Uro26- Items Lighting nOn- moral applicationsindependently Indents on plans eligible non nasal light applications. include sg. It. area of each li ifing petrol zone: Indicatefor on plans that en -visual lanais re cmnoled from both general area lathing end oar 110M° appllraeons within the same space; Indicate method of manual lightly control and applicable automatic lamas wnbol NA CI0626 Mm6 DBMppupmem for sale or demonstration Indicate on plans that light rig euignant Ia sale or demonstration are controlled independently from both general area lighting and other lighting app'als'Oren the same Inthcate method of manual lighting Intro and applicable automatic lighting c005o - - - - YesCA052 5- Ilem 7 Mof egress Means egre fghing IdeMny on plane egress mores that (Linden as both normal and emergency meanSNegress Iunnnd n: Provide calculationof lighting power density of total agrees. lighting: n mml egress Milting power density is greater than 002 Msg. it, Indicate on plans egress fixtures npunng automatic NNoff during unoccupied periods: Indicate method of autornatiC NULdlantrol - - ¢1e8.ETB - _ Hot 0406.z.] Exterior lathing Gongola Indicate on exbador IigMng dans and fixture sdte/l% We automatic fighting control method. control sapience. and locations served; For building facade and landscape fighting indicate automatic Controls shut off lignOno as a function ofdawn/dusk and had opening/closing lime; _. __ For a other clear polder, kdbte automatic conlds Nut Off lighting as a tendon of available da3lght: Include Word sequence that also reduces Ightng power by at least 30% between l 2am-m, or from l hour Sr dosing to tel hour before opening, a based upon motion sensor - XA Ca05.s.1 EiterW Wikdy grounds lighting controls For butting grounds 'figures pwatts dureeler than 100 waManta on whether ndures seta emery greater than e0 lumens or: ere mntroled by motion send or are exempt lighting ng pet xA U05.25 Plated after C422]) Area controls - Master control switches and circuit n power location/0of menet control switch/se) intended to control multiple independent switches; circuit breaker may not be used as master control r conSwitch: Vaiy that a 20 amp circuit controlled by a single switch or a W mho end is loaded beyond 80% ADDITIONAL EFFICIENCY G060 PACKAGE Enhanced clamant Ightng ands OPTION - ENHANCED DIGITAL LIGHTING CONTROLS To ("Angry with WIWnd efficiency package pen, idksa on pens all interior fighting fixtures that are Mdhieualy addressed provided with song nuous diexception, or exception taken; Induce calculation of percent total Installed interior lighting Owe tat is configured wth required enhanced lighting aafd funlonelmin 90% to campy with at/digonal emceri pelage pap) NA Lighting Summary, cont. Fame for Canners* Buildings irgWine LTG -SUM stales and al RI Reviled nav2017 2015WENM01m-'ter Energy Code CmFince R2, R1, 0.4 over 3 Prolog TNM: 6owlerolukwlle Dale 11/14/2018 Change of Space Use O IncEWIinterirlghting systems in areas hider -going a change 'n[TAM use ere rgurWenm co Mth LAPS for the new space types per Tires U05.42(1) or U06.42(2). ist* IMwro, spans 'puffing LPD upgnda to the current Code in Reposed LpmGp Welpe the M OG-INT nD orLTG-INTSPACE Form Interior and Exterior Lighting Alterations Select a9 Lighting Poner and Lglr4Yg elements Mel°PPM tome nags 011ie retro,a project. Ifprolsd n[Ydesa ndnate of spaces ewe less Mn 50% of the adding adores ere replacedMuMaspM9ced Lighting Power nluerlglmre Peminp garage E4.Mr ltlbtlng Sox a more of casting are replaced 1 0 a --- - l _ 0 0 a - a fixtures ,ell Mane TG XT km form. nuns NIMRUW➢WIgMYrg garages, 0 _- - a corm). MM iota/AMlnsmnpYceo In Proposed e2rP01KKe»mnkig and roll ru arempimt Lwtlw Sn%M.aseCI Lang mlabNWlrpananwdmey -existing total wattage not increased 50% or mare replaced - Total I Warp )pod per Sectors C4054.2 ant C405.52. I skimp Wattage taws a LTGINT5Lo than Spareplaced . lttNIiMM WattgeltabpoewGM,b8LO,LTG.l 50% thrsho MppGslonum,eof INTSPACfrranorsacesa SaxgreMdanfgres5rnrllumin luminaires. na.Wtl wn.g. for aae,b,nmmalrea. 50% more Whoa Momeh. Men prattle We npneb lighting to pop' options. Space undethe Mogshes Op. of conditions. Spaces may undergoing shesamelam ryyaM power conbe UanMdrW MW era IgNbgeatar enpWrmee isms RWrrownts. C50.J66v efdMmal requirements. Ipubarenh. Al alteration dp.rCmnled. mate wmnvmetl Per CMa3. M [aanprmbeM9madaro 0 MCMMbrorasbbNp *W'g ,� and existing d MTflplmdn rend changed over Wnew• Austin.toresn Include new . eaetTg-to.emah LTG-INT-SPACE or powerewraw.[psngbnenlnunsMures PCF •Of LTGtmpr for ;Manor epesa.MPerkbg lighting Controls thaw owing insulted b nrve added fixtures snits fixtures relocated to new awtoo New orrrovmo-11IgINg panel interior lgn0y l 0 I 0 PeMpgnage EewnrliglNng I 0 I j 0 0 0 btraepegimngedrgered - MntiMre, unwnmewreamban& rerca062T.WyFymlrespMtln a r .: moSOr =gruSpace New wiring n circuit For :Maier Fabling. prmpa reamed menus coMMs per C405.2.3 ocwpmy Lcnlrohper c405zsend applk (m specific lgmag controls per 040625 For eaeh, IgnIbp. amide required controls per C4051] New eased panel -Roude all epplxada Irhrng controls es noted for New Wring end automatic N'W s*gch COMMIS per Caw.22 Ragnyred NlnIYawe.-povide al/ raptured lghng COMMA Mal apply a new Mlakr,pm. AopLORgn speak 1phStg control provisions per C40525 donorWA fr to resnogured Maces Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG-CHK State Energy Cede Compliance FOmabr COmmerdel Buedjge iry]uyng R2, 0.3, R4 over 3 sNMs Yd all RI Revised Nov2017 2015Washi glen Paget 'MN: Bewerorukwlla Date 11/14/2010 The Mb,n Inbnrellm is lghang.=tor. requirements inith necessary b leak pmO W Jason b comp lance with the and elechicel Appkadny (ys.no.ner Code Salon Component Com}Jance nbrmaon epulled in gem* documents Location in Documents Building Department Notes INTERIOR UGHTING POWER & EFFICACY T.p C405.4.1 C4054.2 ladW ell NmlnalrsnIgllnmupon scheated nabs Sale ryma lamps, ballasts, and mniacmrers rated was per E-3W NA NA NA Teal Cemented IMNr Miffing Pager fnw: non dale aver exception Ne^4Nepema ce forms ads compliance forme indicate Me exception applied; 10en1N rigging equipment eligible for llgnln power exemption in Uwe schedule and in complanoeforms;kd'wate the exception apples' Indicate that ep lighting equipment Is In addition b general area lahang and is con roved uMependeng NA Com.3 E,Ixagne Indicate location of exit signs on plans and rated wage pet plus In Ip0ON fixture schedule (maximum 5 watts per We) ET0. NA U65.1 LMJlgyndwallg LnNntarmgNscy If high efficacy exception is pled to pemone,ny Installed lighting enures dwelling indicate In lighting a Ore schedule Vamp m ( g efficacy per 0.404.1. calculate percentage of Nl with high efficacy lamps in projectgn75% tocomply who exception). interior LlBM1tlnp ancaw at mdbaNsmpleaepMMrn NA 0405 21 Sniffing Am Method Complete required mmpaence forme pmWsed xattage per bdWpaadw notsaed maximum al wed wattage per gaffing area, IdentifyIaaMns of building areas on ohms YeeGOSa2$ Method fos - total proposed wattage Complete required complianceforms does not exceed maximum allowed wattage; itiy1St s0 specs trifles on plans. including retail display areas, lobby an A exhibit display areas. and ceiling heights as applicable 1-1ea ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY NA C40Ba ed Miffing Power dandy To comply efficiency package option.strin compliance forms that total Connected interiorReN lighting wattage's 25% less than the total maximum allowed lighting wattage via Building Area Method Or SpaCeSy-Spate Method NA C40.3 Reduced lighting power density dweller unit lamp dwelOV proles* with dwelling units. to ppmpy with alemnal ardency package option indicate in lighing for W schedule it in'nleer fixtures have el6mry rang W W emcee pa watt or more. cakulste percentage W fixtures with lamps that wag have this efficacy rang (mho ge% to comply with tplkn) EXTERIOR LIGHTING POWER & EFFICACY NA CA05d2 Total connected amNg Power Include all luminaires in liehln0 fixture Schedule; indicate roes. types, lamps, ballasts, and mnufcluers rated watts per fixture Identify exterior pptmlins eligible ter kgdrgpaw s m mptnn on plans end'' nplinceform% indicant exceudon applied; Indicate that exempt exterior lighting is controlled Independently from non-exempt exterior ygming, include exception dawned for each fixture or group of fixtures under exception category NA Table bz(1) Exterior fighting acne Indicate building extern ugh' g zone s defined by the AHl XA Exterior building grounds Exterior bgang building grounds fixtures rated thany at greater 100 watts that are complying based on efficacy, Indicate rated lamp efficacy tin lumens per watt) in fixture schedule U0S'S'1 HA Un55.R Ex4nolBMag Power m9htki9lculati Complete required compliance form- proposed wattage for exterior lighting plus base site allowed does not exceed maximum alerted Interior Lighting - Space -By -Space Method LTG-INT-SPACE 2015 Washagion Sate Erayy Code Co lance Fong for GOn,mrcil Bulpn08 MSS tlq R2. R4over3&ones and al RI Revised PropdTlle; BOW.remkwlle pit 11/14/2018 CdICllldilOR Area'. RN &IIMg Depvarblt L e 0 New Construction eaWdltion. Addition stand alone Qwising O Spam eMlere c 50%of . Spares wherea so%M Q s pass allere Me W 4minalm ererepeal umnares are replaced la Mrgl B(CSON LPA calculation Type • senor 0 Additional Efficiency Pacyage DOA" C406.3 Reduced Interior Lighter PowerPor TomreH nth C400.3 Me Proposed LP() ant. 25% aaw than tie T rya LPA. Referb C[CB J for additional requirements, Lyn We Maximum Allowed Lighting Wattage'''`' Location (plan N. MOMS) Space Type Legg Iffightlan2 GAMS Intent Ares fin' flossed Ware per It' Waits Meted (stls/K setae) 1124cade Loungethrealzoonx all other 3700 0.560 2146 Lobby NNENLM LVspley Allowance from LTBMT-DF tAV 1CTE Proposed Lighting Wattage"' Total Area 3700 Retail Display Moreno. from LTG- W T-DI3I.AY Allowed Watts 2146 Lore ((plan A. room g) Fbaur.D Iplk„mnEA3E Number of Fixtures Wt2 AlgaeAlgaePnymd Welts 112 Made a'BLyaded LinearFlumaant F28T5: Bectrorec Banat44 30 Ill Arcade .My 3a Pendant BOIL incandescent 11 e0 660 Proposed Retail Display lighting from LTG Nr-DISPLAY TommopuM Wass nay not fumed Tot aMonad Wane f inted&LliMag T col Proposed Watts 1980 Interior Lighting Power Allowance COMPLIES HOS I -UVeN unique space rapes per Taal 0405.e 2(2)Wx mom In the project scope. Saba apace Wu category from drop Lion menu. Note 2- fridieate miMO heghl for atriums an spent u1mLMp the cagy Mghl adjustment per Table C4054.2(2). Fabomadtmll Nos 3- Lis, all proposed lighting fiuures Me tdng esnpt Iglbng eWneot and euskg twrxei Mures. Note For proposed Spurs DescripUon.Mdicete Sure type. Mnp :We fag. T-8). mar Oa °ISM& in ther and baba lyp (IMriude4 For track aghl g, fist1 9 ofM track in feet) in addition lamaMae. lam end belles, info Notes For lighting equmment eAgible for [weapon per C4054.1 note exception number nd IOWA Masi; WManx. Naafi Editing ''Wares shell be included M the Proposed lighting WMage table hi the sane manner as new Suns. Wenttly es westing s Sure description. Note) Farproposed Wetts94ore°MNaiM MOlra*e wattage for mashed lamp endbalba uMsg nano( ofoNarapproved source. For Irsractumt OWln9 e'tom iwninares er the we�eh screw -in Md theel'eibmwc Forter Me / line Image udnaG way systems, maximum input genoM the f the n(ofMe terrywanege).awetFor rW0(5 larger Mac, seltama✓e welbge w50 eetMwel root orenter the wattage MA ofprmanen/ current limiting SeNee. Note S- Lobby ANEMib Display Allowance is independent of Me Magnum Armed Lighting Wattage. Enter W proposed lobby erWurhfr display Sures h LTG-INTDISP(AY form only Role 9 -calculation Area DeleAs' a. Lighting fixtures Si a buikrng edditon tiny comply aea stand alone project. w theymay be Lanined wish the overall egging boning NghMg systems Io demonstrate compliance. Rele to 05021. b. For Aerations end bulldog eddllons. prods Space Type and grog Mirioe areas M the Magnum flexed Lighting Wattagetable la hulkingss�tre n eta oomph as combined run Ise overall meting Mimingyhtne system & Include ell apMT be misting Space Types reas. s fl n 50% M eustog IglMg Mures wll be replaced, provide total meeting fighting wattage /poor to abnlon)in ma space provided d m.Motown Mond Lighting Wattage table. c If WW1; alteration project includes some building areas or spaces wh/a a 50% of kmMsires era replaced, and other areas or spaces whore 250% elNmmares are replaced. then Mese areas or spaces may be documented Separately Ifm"nrpre forms lb m be Nreted to dMatmmte compliance Mr uMMMl scope of the alteration project, describe scope twee ' u Nor r Lighting, Motor, and Electrical Permit Checklist, Pg. 4 NI15 WaNngmn State Em,gV COW Comnlmnce Fwme m,Ccmme,clal B,tlldinos incudino R2, R3, R4 era 3 dab end eIR1 LTG-CHK Revised Nov 2017 Bowlerorukwlle IDW 11/14/201* The W lain information is necessary to check a permit application for compliance With he lighting. re W, and datum regalia/tents n the Appbwlry (yams,M) Code Section Component Compliance inMmlbn required In permit documents Location In Documents Building Department Notes LIGHTING ALTERATIONS Yes C5036 interior and Parkingexceed garplighbrg Nbre alterations where s so% of existing lum:nsres in interior epm(v) orW order garage are replaced:indicate compliant.path 1W Idry space -by -space orspace-by-space method): include all new m andisting remain luminairesin compliance form (LTG-INT BLD or LTG wattage doest t INTSPACE); indicate proposed lighting no maxim allowed pe p-nce pah Where < 50% of existing luminaires in interior space(a)or peeing garage replaced, inthcate total existing igMYrg wattage in each space poor to alteration: 'dude all new and existing -to -remain luminaires in LTG-INT-SPACE form: Indicate proposed total lighting wattage in alteration area does not exceed total existing lghtng wattage prior to alteration EA*5400 NA Exteriorlighting Where 50% et existing exterior lighting wattage is replaced: include all new and existing -to -remain lin LTGEXT form, indicate proposed total exterior lghting wattage does not exceed maximum allowed Where r50%1 existing exterior lighting wattagepl a:ficure�aw aindicateaonttelxe lygtlghy - ge - 1 Lnes ' not: ode qe Indicateproposed total exterior lighting wattage does not exce total 'Matingwattage prmr to alteration Yes C%UB IMeiwl4Ntly MNy Im'tnna a(01.05.2.3): Ymete new wingis ..installed to serve new interior luminaires and W luminaires lii indicate ght applicable)manual Ing controlsprovidedl s occupancy sensor (C40521), daylight responsive (Uea247 specific pp' IC405251 exit signs(C405.3) tl Elea. ae NA C503.6 Exterior lighting wlnrp auaratina Where new wiring is isW and Wwmma relocated to new circuit indicate exterior rla.'IMg controls are provided (C40527) Yes C503.6 Lgnarq panel alrabpg Whore a new Ignmp panel rs metalled or an existing panel is moved(all new raceway and conductor wiring), 'pesetafighting controls are provided (as applicable). same provisions as wiring alteration: time switch controls and manual light reduction controls r C40522) E100. 520 NA cS0.9.0 !Marta space figuration where interior space(s) is reconfigured (permanently ialled walls orcaging gh pa li indicate gnu g controlsare provided as applicable)- same provisions as lighting panel alterations NA C5042 Lighting rpm Identify existing luminaires being upgraded with Pug, and/or ballast replacement: indicate fixture aleatin does not Increase existing fixture wattage NA C5051 change Oreganoua Identify spaces on plans where the bulIng area type or space uYIneeobeR2am(is )bwdorne(seemchanuxged(ahfrovmvOpm mpatoanemothi a oYpesTmaNn method); Include all new and mklingiotmwn lu"lnam In compliance form (LTGINTELD a LTGNT-SPACE): indicate proposed lighting wattage does not exceed maximum allowed per compliance path RECEPTACLES Yes U0.5.10 Dontrolled 1pmg B IdentNalcontMM and uncontrolled receptacles on electrical plans in each space In Mud/ they are requited: lnctude receptacle configuration such as spacing between controlled an0 uncontrolled. duplex devices, etc: Indeed on plant whether the method of automate control for each controlled receptacle zone is by compnt sensor or programmablefine fdsy OOM1 5.-110 E-200 ELi 9-02 1 1 Lighting, Motor, and Electrical Permit Checklist, Pg. 1 mmwdal Bvadnoe uMWbq R$ P3, R4 over 3 stories and sli Rf LTG-CHK Revised Nov2017 Prefect TItle. aoMxoTuMN Date 11/14/2018 Theta:win intonation l namfay to Neck a permd application Oar mnplince with the lighting. motor, and decokd requirements in the ApplicMM (Ywno$e) Cale Section Longmont EmplageInkmlWm rewired in permkhaument Location In Documents Building Deportment Noted LIGHTING CONTROLS Yes LiOia Lghing controls, general For all lighting futures, indicate Potty cMbd method on plans for spaces and lighting scoots) served, or exception taken BtgO'F2g0 eA C405.3 Lumi aire level Iyyy collude (LLtC) Indicate on plans all fixtures provided with LLLC In lieu of CA052 fighting commie' provide description of/noes Ages and penormonce paremebn NA UKt Lightingvi dwelling unite For permanently installed lighting fixtures in Tway unit, indicate lyhling contra method on plans for spaces and lighting zones) served, or demonstrate compliance with hgh eigry exoeplion Yes G0523 C40521-I ULS22a L.pgeg.d G0525 Manual contras belmte on plans the method of manual lighting control (wtelhet combined with cmrpancy sensor, automatic light reduction. daylight responsive or specific appbmtm controls). location of manual control.device and scth area or eapplication r serves E100,E200 Yes C4052.2.I CA0522.2 U05.21 Manual interior light reduction controls Indicate on plans which method of manual 60% lighting load reduction Is provided. Cr whether lighting load is reduced via A E100, B0 occupancy sensors or delight responsive commie Yea C40522 Method of automate shutoff controlIndicate indicate on plans the method of automatic shut -en u.Mrol during unoccupied periods (occupancy sensor. time switch or digital , switch). for allghtbg zones; wham wheautomatic shutoff is provided by other methods occupancysensorw digital Inner switch) or wntA tea switch control exception applies E100.8200 C405.2.1 C4055.2.1.1 Occupancy sensor controls Indicate on plans the spaces sertN by occupancy sensor¢ Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50%an or serve a space eligible to automatic 100%-on per exception NA Ure.2.1.zcontrols, Occupancy sensor warehouses Indicate alsleways and open areas in warehouse spaces provided with occuwe-/ Sensor controls that reduce ightiy power by 50% Ys G0622.1 Automatic time swrh controls mimic locations cif override switches on plans and the lighting um(s) served, include area sq. IL due.E100 NA UW25 DIMS arcrswllsh Indicate digital timer switch control indigos- manualWoff, time delay. midges and visual indication of impending lime -out NA G062Aa U062A.3 Deylpmzmea- 9keII2Mand toplight octets primary and secondary sidelight daylight zone areas On piers. bdude sq. if.; Placate WplgMNNgt zone areas n ears Include M.A.; For smell vertoel HIMbY)M assemblies (rough Wady teas then 10 percent of Amery deyigh' zone) wiles dayl9M responsive controls are not required. provide Mnnl mien a- todaytighlzoneakulatvh(s) HA C4F.2A Daylgmaamsie colter !negate On pans ggMy zone(*) served by daylight reepnahe COMOS; ldenlN wde ghl and mpgM daylight zones that are net provided with daylight seMSng Confide and the exceplcn(q that spry', Indicate on plans the lotting load reduction method continuous dimming. stepped dimming that provides BOSSES two evensteps between 0%-100%of rated power Indolethat daylight sensing controls are configurMm completely shut Oil all cOMrolbd lights in the lighting zone 14 C40623 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that requite spedec application lighting controls per this section NA CMSz.s- Ions 182 Di play.Mewzrl lighting Indicate on plans that display and accent llghling, and display case lighting are controlled led independently from bothgeneral area lightingand other lighting appicatpe within he same space: Indicate manual and automatic lighting control Method Lighting, 2015 Washi Motor, and Electrical Permit Checklist, Pg. 5 LTG-CHK Oren State Energy Coda Compliance Forms for Commercial Buildings mduding R2, R3, 0.a Dew S abies and all RI Revised Nov 2017 BawlmTukila Date 11/14/2018 The grown intamaan ISneceesay b ehak a pemltappimbon for compliance tit the lightng, motor and electrical tyulre'nnlsIn the Applicema,y Oetnonal Cede Section Cempnent compliance Information required n permit documents Location in Documents Building Department Notes MOTORS TRANSFORMERS, ELECTRIC METERS. INTERIOR TRANSPORTATION Ts U05.8 eeclnml transformers Include electrical transformer schedule on Seaga! plans: Indium transformer Mae.efficiency. or exception taken Ea00, Edp NA C405.7 Nulling unM Secaaa edgy wraumplo Indicate on electrical plane that each dwelling unit n Group R-2 has a Separate electrical energy meter NA COMB 83 effienog Include all mobs including Mannar hp rn06a. In electric molar schedule an electrical plans:indicateindicatehp. rpm. rated eflmency or exception appal Nam U069.1 Revetucae For luminaires In each elevator cabprovide calculated average efficacy of combined fixtures that Indicates efficacy Is not less than 35 lumens per watt: Indicate ratch railed watts per n W elevatorfe vator cab ventilation do not exceed 033 watts per des' Indicate automatic controls the/ de -energize lIMng are ventilation fans when elevator is stopped end unoccupied fore period of 5mnutes Of more NA CA05.92 Escalators and mdMywaka Indicate escalators comply with ASME AI 7.1/CSA BM: automatic controls are configured mr 1,m operations speed to the minimum permitted when not use NA U05.9J Bgpr,eetivedrM Indicate all oe-way down or reversible escalators are provided Sib a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING Cx) NAPow M3 Scope of electrical commissioning lighting systems donln9 Indicate that all ethnical systems (receptacles, transformers. 'Mors, secs and horizontal transportation) for w,Ich the WSEC requires l fns and / or configuration to perform specific functions required m be com,edped; Where total building lighting bed a> 20 kW or where Mal Igbting load of mmmaires respiring daylight setting and I a occupancy control S 10 kW indbe that all aubnubc lighting control system/sae required W be ep,mgkned or provide building lighting power calculation demonstrating eligibility for except': NA C405.13 GCB.I1 C408.1.2 C408.1.42 L103e Commls¢bnYN ,orpkemaMn COMIllucern documents Indicate Cx requ iremna In plans and epecifimlra for all applicable electrical end IehM° control Syeterre per UMi Include general summary with at minimum Items 1 hm4ol the Cx plan per C40012 including: nonage description of acavles.rStpnddmndhe Cx team schedule of activities including serficsm of pmMo close out Mwmedetbn per CI03.6 and ammo r Interest pn fireweed); Include M general summary that a Cr( project spat or Compiawn Checked (Figure CAM 1 A2) MN be completed by The certified Cx Professional end pleaded to the owner Moe to the final eleddmsl inspection NA C408s1 Functions performance toting Identify in plans and Spec'( 'of the intended operation of all equipment and controls during all males of operation, induding interlacing between new and exdnBMreman systems Meath PROJECT CLOSE OUT DOCUMENTATION NA e1036.3 Project dose out daaneMdkn requremeeffi Indicate in plans that project dose out documentation is required inducting WSEC tlghling compliance forms end calculations that document all interior and exterior lighting area and / Or surface types fighting pawn' allowances and installed densities If anon is s for any question, pros explanation: End of Lighting, Motor & Transfomew Permit Documents Checklist EXPIRED NOV -10 2Qt9 N Pap 0-NEC ' ata22DE City of Tukwila WILDING DIVISION fECi:IVEt1 CITY OF rl'UtONLA NAft0®1018 PERMIT CENTER The Woolworth Building 233 Broadway, 161h Floor New York, NY 10279 Tel: 212.354.9240 Fax: 212.354.9253 CMlisonRTKL Project No: 003-180285.00 Owner Bow lero 222 W 44th St. New York, NY 10038 Tel: 817.938.5860 www.bowlero.Lvm Consultant ru HENDERSON ENGINEERS 8345 LESUITE 300 LNEXA, KS DRIVE.4 TEL (913) 7425000 FAX(913) 742-5001 %W N.HENDERSONENGINEERS.COM 1850004475 WA CORPORATE NUMBER:1754 EXPIRES 06/30119 Amendment #1 CllenUOwner/Project Address Bowlem Corporation Client Address 22 W44th Street. New Yolk, NY 10036 Project Address 100 Andover Perk W #100, Tukwila, WA 98188 Issue Drawing Log ISSUED FOR PERMIT AMENOMEM81 11MR2018 RW1)2019 Seal Sheet Identification ENERGY CODE COMPLIANCE ® 2016 CMIIsonRTKL Inc. E-400