Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL19-0363 - ELEMENT BY WESTIN - ELECTRICAL SYSTEM IN SINGLE PHASE DEVELOPMENT OF 5-STORY HOTEL
ELEMENT BY WESTIN 515 INDUSTRY DR Apn: 0223400070 FINALED 04/14/2021 ELI 9-0363 Parcel No: Address: ^ xx m Tukwila *° ~ v n u n^ oa Department of Community Development 6]0OSouthoenuerBoulevard, Suiue#10O Tukwila, Washington 98188 Phone: 206'431'3670 Inspection Request Line:I06'43O'935N Web site: http://www.TukwilaWA.gov 0223400070 515 INDUSTRY DR Project Name: ELEMENT BY WESTIN ELECTRICAL PERMIT Permit Number: EL19'0363 Issue Date: 5/22/2019 Permit Expires On: 11/18/20I9 Owner: Address: TUKWILA HOTEL GROUP LLC 173SSOUTH 19THAVENUE SUITE 8, BOZEMAN,CO, S9718 Contact Person: Name: KULONKxUSSER Address: 4795O8KLAND3T'DENVE9,CO, 80239 Contractor: Name: Address: License No: Lender: RELIANCE ELECTRIC INC P0BOX 84U575'H|LLDAWE, U[84784 KELiAE1926RP Expiration Date: DESCRIPTION OF WORK: NEW ELECTRICAL SYSTEM FOR THE ELEMENT BY WESTIN HOTEL IN A SINGLE PHASE DEVELOPMENT CONSISTING OF 177 GUEST ROOMS IN A 5-STORY BUILDING. Valuation ofsingle family: $IOO Valuation ufmVtomnn: $2'717,545.00 TypeofWork: NEW Fees Collected: $25,152,03 Electrical Service Provided by: PUGETSOUND ENERGY Water District: TUKVV|LA Sewer0mthc1: TUKVV|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: international Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: ized Signa National Electrical Code: vVACities Electrical Code: VV4CZ95-46B: WA State Energy Code: 2017 2017 2017 2015 _ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions nflaw and ordinances governing this work will becomplied with, whether specified herein o,not. The granting of thispermit does not -presume togive authority toviolate orcancel the provisions ofany other state orlocal laws regulating cugo�q�tonorthe pe�ormanceufvvork. |amauthnhzedtosign and obtain this _ development rermit—Rrd, e conditions attached to this permit, Signature: Print Name: _/ Da�e:�� —Z-/� ( / / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended orabandoned for aperiod ofl8Udays from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)u3O-9B5U 2100 ELECTRICAL FINAL 7003 KOVGH'|NELECTR|[AL 7002 SERVICE 7001 UNDERGROUND/SLAB Parcel No: Address; City of Tquwila Department of Community Development 6300 Sowthcenter Boulevard, Suite #100 Tukwila, Washington 9Q188 Phone: 206-431'3670 inspection Scheduling: h«tpu://tukm-egov.anp0pvcnm/BP/indmw.htm| Web site. hUCu://vmww.Tukwi|mVVA.wpw 0223400070 S15INDUSTRY DR Project Name: ELEMENT BY WESTIN ELECTRICAL PERMIT Permit Number: EL19-0363 Issue Date: 5/22/2019 Permit Expires On: 7/4/2021 Contact Person: Name: Address - License No: Lender: Name; TUKWILA HOTEL GROUP LLC 173SSOUTH 19THAVENUE SUITE B, RU0NMUSSER 4795QAKLANDST,DENVER CO' 80239 RELIANCE ELECTRIC INC POBOX 84US7S,H|LLDALE,LIT, Q4784 REL|AE1926RP Phone: (720)250'7675 Expiration Date: 3/23/2021 DESCRIPTION OF WORK: NEW ELECTRICAL SYSTEM FOR THE ELEMENT BY WESTIN HOTEL IN A SINGLE PHASE DEVELOPMENT CONSISTING OFl77GUEST ROOMS |NAS-STORYBUILDING. "REVISION 1Z/J3/2O'ADDING LOW VOLTAGE TOPERMIT PER CUSTOMER REQUEST" Valuation of single family: $0.00 Valuation ofmf/comm: $2,767,545.00 Type ofWork: NEW Fees Collected: $26,201.21 Electrical Service Provided by: Puget Sound Energy Water District: Tukwila Sewer District: Tukwila Current Codes adopted bythe City ofTukwila: International Fire Code Edition: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVA[I9646B: Code: rEmN All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Scheduling: https://tukw-egov.aspgov.com/BP/index.html 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROU 0 LECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7002 SERVICE 7002 SERVICE 7002 SERVICE Tenant Name: CITY OF TUKWl r1 Community Developme ._ Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov RECEIVED Electrical Pet No. 0 97 Project No. Date Application Accepted: Date Application Expires: (For office use only) 0 6 2019 ELECTRICAL PERMIT APPLICATION COMMUNITY Applications and plans must be complete in order to be accepted for plan review. 01-V1 1 O1'MFNT Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 515 tr) 1.1.5 r4 E1 e mev. Uj t� Lc� es i-i ✓� PROPERTY OWNER Name: Tu�I'.UJ► �ei +(' ` C 6�e�7� C C Address: 17 35 5. lqi" Aye 5L. }-e .B City: State: Zip: C&V a g 90 Z e Mrlu. N my CONTACT PERSON — person receiving all project communication Name: ,�/� r\u...i` e n in, 5e-r Address: ii7ei 5 occ_kQAd J'1_,ee-1/2-- City: e_.-Aqt.,,e State: Zip:303I co�V Phone: 7 t. 0 .� 5 d _ .76.�5Fax: Email: c VA 0 f) ii MiAssteQ fel c Lir -CCiMsCOn King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: on Address: 4 7R5 ©a-ii ICctnd. 5+-ree_+ City: �Y1 Qe- f State: ,r^� Zip: go a37 Phone: 7x)�,..vi9 _a(t,sDFax: 7 o 7y4 —a85 1 Contr Reg No.: Exp Date: Tukwila Business License No.; rU u c— c g c t (I I Valuation of Project (contractor's bid price): $ t -% 17) 51-1 S o OD I (' Scope of Work (please provide detailed information): /1 f Q�g { (t 4 C.a mrnuf; C&Tip �11 +j t'e it w .tn d n\ n rax j pLU eIT - r new .E.I col c vv i- t-k.e i i 9 S 14e IA) o Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: is New ❑ Addition ❑ Service Change ❑ Remodel D Tenant Improvement gLow Voltage Generator yi Fire Alarm Telecommunication Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light W:\Permit Center\Applicat ions -Handouts \Permit Applications \PDF's\Electrical Permit Application Revised 1-17- 19.docx Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE LIJ New single family dwellings $180.00 (including an attached garage) 0 Garages, pools, spas and outbuildings $120.00 ea 0 Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES 0 Service change or alteration $120.00 (no added/altered circuits) 0 Service change with added/altered circuits $100.00 number of added circuits $10.00 ea 0 Circuits added/altered without service change $60.00 (up to 5 circuits) El Circuits added/altered without service change $60.00 (6 or more circuits) $10,00 ea 0 Meter/mast repair $80.00 0 Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES 0 Temporary service (residential) $60.00 0 Temporary service (generator) $90.00 El Manufactured/mobile home service $100.00 (excluding garage or outbuilding) 0 Carnivals $100,00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Nan Mailing Address: 7.0.esos 81-10G15 LLD ALE' tA,T Date: (10(41 2A 61 Day Telephone: City State Zip WAPermit Center\ Applications -Handouts \ Permit Applicat ionsaPDFAEleetrical Permit Application Revised ti 7-19.doex Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $15,411.72 EL19-0363 Address: 515 INDUSTRY DR Apn: 0223400070 $15,411.72 ELECTRICAL $14,449.86 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $14,435.31 PLAN CHECK FEE R000.345.832.00.00 0.00 $14.55 TECHNOLOGY FEE $961.86 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17704 R000.322.900.04.00 0.00 $961.86 $15,411.72 Date Paid: Wednesday, May 22, 2019 Paid By: RELIANCE ELECTRIC Pay Method: CHECK 11280 Printed: Wednesday, May 22, 2019 1:11 PM 1 of 1 CRWSYSTEMS taro Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID „ . . PermitTRAK '1809.31 EL19-0363 Address: 515 INDUSTRY DR Apn: 0223400070 4,809.31 ELECTRICAL $4,809.31 PLAN CHECK FEE PERMIT FEE MULTI-FAM/COMM R000. 45.832.00.00 R000.322.101.00.00 0.00 7. 8 0.00 $4,801.93 TOTAL FEES PAID BY RECEIPT: R17668 $4,809.31 Date Paid: Wednesday, May 15, 2019 Paid By: RELIANCE ELECTRIC INC Pay Method: CHECK 11268 Printed: Wednesday, May 15, 2019 4:45 PM 1 of 1 APWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY • PAID PermitTRAK $lo,892.83 EL19-0363 Address: 515 INDUSTRY DR Apn: 0223400070 $4,931.00 Credit Card Fee $143.62 Credit Card Fee R000.369.908.00.00 0.00 $143.62 ELECTRICAL $4,787.38 PLAN CHECK FEE R000.345.832.00.00 0.00 $4,78738 M19-0071 Address: 515 INDUSTRY DR Apn: 0223400070 $2,778.87 Credit Card Fee $80.94 Credit Card Fee E R000.369.908.00.00 0.00 $80.94 MECHANICAL $2,697.93 PLAN CHECK FEE 7 R000.322.102.00.00 0.00 $2,697.93 PG19-0064 Address: 515 INDUSTRY DR Apn: 0223400070 $3,182.96 Credit Card Fee 92.71 Credit Card Fee I_ R000.369.908.00.00 0.00 $92.71 PLUMBING $3,090.25 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R17504 R000.322.103.00.00 0.00 $3,090.25 $10,892.83 Date Paid: Friday, April 26, 2019 Paid By: TIMOTHY WILSON Pay Method: CREDIT CARD 06281G Printed: Friday, April 26, 2019 3:12 PM 1 of 1 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 04/26/2019 03:12:09 PM CREDIT CARD SALE VISA CARD NUMBER: **********3824 K TRAN AMOUNT: $10,892.83 APPROVAL CD: 06281G RECORD #: 000 CLERK ID: kandace X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Permit Inspections City of Tukwila Permit Number: EL19-0363 Applied: 4/26/2019 Approved: 5/14/2019 Issued: 5/22/2019 Finaled: 4/14/2021 Status: FINALED Parent Permit: Parent Project: Details: Description: ELEMENT BY WESTIN Site Address: 515 INDUSTRY DR City, State Zip Code:TUKWILA, WA98188 Applicant: ELEMENT BY WESTIN Owner: TUKWILA HOTEL GROUP LLC Contractor: RELIANCE ELECTRIC INC NEW ELECTRICAL SYSTEM FOR THE ELEMENT BY WESTIN HOTEL IN A SINGLE PHASE DEVELOPMENT CONSISTING OF 177 GUEST ROOMS IN A 5-STORY BUILDING. **REVISION 12/23/20 - ADDING LOW VOLTAGE TO PERMIT PER CUSTOMER REQUEST** N P CTIO 5 SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS PM UNDESLGARB UND Jim Benner Nephi - 435-414-3256 Notes: SERVICE Jim Benner Nephi - 435-414-3256 / low voltage LV4 Notes: ROUGH IN ELECTRICAL Jim Benner Nephi - 435-414-3256 Notes: 6/19/2019 AM 6/19/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 414157 Notes: PARTIAL APPROVAL/#1 O.K. -UFER AND CONDUITS THROUGH FOOTING AT ELECTRICAL ROOM PARTIAL APPROVAL/#1 O.K. -UFER AND CONDUITS THROUGH FOOTING AT ELECTRICAL ROOM 6/24/2019 AM 6/24/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 241581 Notes: PARTIAL APPROVAL/#2 O.K. -SLAB CONDUITS IN ELECTRICAL ROOM -LV SERVICE CONDUITS UNDER FOOTING PARTIAL APPROVAL/#2 O.K. -SLAB CONDUITS IN ELECTRICAL ROOM -LV SERVICE CONDUITS UNDER FOOTING Printed: Thursday, 14 October, 2021 1 of 13 it SUPERION Permit Inspections City of Tukwila 7/5/2019 AM 7/5/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 335636 Notes: INSPECTION PERFORMED BY ROGER CHICK WITH BHC CONSULTANTS PARTIAL APPROVAL FITNESS ROOM SLAB - POWER & LOW VOLTAGE8 FLOOR BOXES LOBBY - 9 FLOOR BOXES - A/C CONFERENCE ROOM - 4 FLOOR BOXES - A/C & CONFERENCE PVC CONDUITE & BOXES PARTIAL 8/2/2019 8/2/2019 SERVICE Jim Benner APPROVAL Notes: PARTIAL APPROVAL/#4 O.K. -TEMP. SERVICE PARTIAL APPROVAL/#4 O.K. -TEMP. SERVICE UNDERGROUND 8/2/2019 PM 8/2/2019 Jim Benner CANCELLED 295469 SLAB Notes: CANCELLED -SERVICE WANTED UNDERGROUND PARTIAL 8/14/2019 AM 8/14/2019 SLAB Jim Benner APPROVAL 14918 Notes: PARTIAL APPROVAL/#5 O.K. -SITE LTG. CONDUITS NORTH.2 x 1" UNDERGROUND PARTIAL 8/15/2019 AM 8/15/2019 SLAB Jim Benner APPROVAL 542547 Notes: PARTIAL APPROVAL/#6 O.K. -SITE LTG. CONDUITS EAST 8/16/2019 AM 8/16/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 482423 Notes: PARTIAL APPROVAL/#7 O.K. -UG SITE LTG. CONDUITS S.E. PARTIAL APPROVAL/#7 O.K. -UG SITE LTG. CONDUITS S.E. UNDERGROUND PARTIAL 8/20/2019 AM 8/20/2019 SLAB Jim Benner APPROVAL 21038 Notes: PARTIAL APPROVAL/#8 O.K. -ALL SITE LTG. CONDUITS COMPLETE Printed: Thursday, 14 October, 2021 2 of 13 rI4 SUPERION Permit Inspections City of Tukwila 2/10/2020 Any 2/10/2020 ROUGH -IN ELECTRICAL Jim Benner NOT APPROVED eTRAKiT Inspection Request Notes: 2/8/2020 10:22 AM Al Jeffs Need a PM inspection for level 5 Contact Name: Al Jeffs Site Address: 515 INDUSTRY DR Phone: 3163035123 e-Mail: apjeffs@keyconstruction.com CORRECTIONS/ #9 -MC CANNOT BE SECURED INSIDE STUD WITHIN 1 1/4" OF DRYWALL -FA BOXES TO BE SUBSTANTIALLY RED INSIDE AND OUT ROUGH -IN PARTIAL 2/11/2020 Any 2/11/2020 ELECTRICAL Jim Benner APPROVAL eTRAKiT Inspection Request Notes: 2/10/2020 2:21 PM Al Jeffs Need a AM inspection for level 5 Contact Name: Al Jeffs Site Address: 515 INDUSTRY DR Phone: 3163035123 e-Mail: apjeffs@keyconstruction.com PARTIAL APPROVAL/#10 CORRECTIONS MADE O.K. -UNITS 524 THRU 544 EXCEPT 543 ROUGH -IN PARTIAL 2/26/2020 Any 2/26/2020 ELECTRICAL Jim Benner APPROVAL eTRAKiT Inspection Request Notes: 2/21/2020 9:38 AM Al Jeffs Need a late PM inspection for level 5 guestrooms. Contact Name: Al Jeffs Site Address: 515 INDUSTRY DR Phone: 3163035123 e-Mail: apjeffs@keyconstruction.com 2/24/2020 8:12 PM Al Jeffs Need a late PM inspection for level 5. Please call Nephi Keate when onsite 435-414-3256 Contact Name: Al Jeffs Site Address: 515 INDUSTRY DR Phone: 3163035123 e-Mail: apjeffs@keyconstruction.com PARTIALA PPROVAL/#11 O.K. -L5 UNITS EXCEPT 543 PARTIALA PPROVAL/#11 O.K. -L5 UNITS EXCEPT 543 ROUGH -IN PARTIAL 5/12/2020 AM 5/12/2020 ELECTRICAL Jim Benner APPROVAL 203470 Notes: PARTIAL APPROVAL/#12 O.K. -GUEST SUITES L4 NORTH EXCEPT 443 Printed: Thursday, 14 October, 2021 3 of 13 5,•'E PARTIAL APPROVAL/#12 O.K. -GUEST SUITES L4 NORTH EXCEPT 443 5/14/2020 5/14/2020 ROUGH IN Jim Benner PARTIAL AL 316-303-5123 ELECTRICAL APPROVAL Notes: PARTIAL APPROVAL/#13 O.K. -GUEST UNITS L4 SOUTH PARTIAL APPROVAL/#13 O.K. -GUEST UNITS L4 SOUTH 5/29/2020 AM 5/29/2020 ROUGH IN Jim Benner PARTIAL 293682 ELECTRICAL APPROVAL Notes: PARTIAL APPROVAL/#14 O.K. -L3 GUEST SUITES EXCEPT 343 AND VERTICAL SHAFT IN 325. -L3 LINEN ROOM 6/2/2020 AM 6/2/2020 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 52241 Notes: PARTIAL APPROVAL/#15 O.K. -POOL SHELL BONDING AND JACUZZI PARTIAL APPROVAL/#15 O.K. -POOL SHELL BONDING AND JACUZZI 6/2/2020 6/2/2020 ROUGH IN ELECTRICAL Jim Benner NOT APPROVED Notes: CORRECTION/ #15 -REMOVE DRYWALL VERTICAL SHAFT 25 STACK FOR CABLE SUPPORT INSPECTION CORRECTION/ #15 -REMOVE DRYWALL VERTICAL SHAFT 25 STACK FOR CABLE SUPPORT INSPECTION 6/5/2020 AM 6/5/2020 ROUGH IN ELECTRICAL Jim Benner NOT APPROVED FROM THURSDAY 115524 Notes: CORRECTION/ #16 -NOT READY CORRECTION/ #16 -NOT READY 6/9/2020 AM 6/9/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 365555 Notes: PARTIAL APPROVAL/#17 O.K. -COVER EXTERIOR WALLS N. WING GUEST SUITES AND COMMONS -STAIRWELL2 EXCEPT L5 CEILING -STAIRWELL1 EXCEPT L1 WALLS Printed: Thursday, 14 October, 2021 4 of 13 i1 SUPERION Permit Inspections City of Tukwila 6/19/2020 AM 6/19/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 381148 Notes: PARTIAL APPROVAL/#18 O.K. -L2 NORTH GUEST SUITES EXCEPT 243 -VERTICAL SHAFT IN 25 STACK -ELEVATOR LOBBIES 12 THRU L5 PARTIAL APPROVAL/#18 O.K. -L2 NORTH GUEST SUITES EXCEPT 243 -VERTICAL SHAFT IN 25 STACK -ELEVATOR LOBBIES 12 THRU L5 6/25/2020 AM 6/25/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 151493 Notes: PARTIAL APPROVAL/#19 Q.K. -L2 GUEST SUITES WEST PARTIAL APPROVAL/#19 O.K. -L2 GUEST SUITES WEST 6/30/2020 AM 6/30/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 574081 Notes: PARTIAL APPROVAL/#20 O.K. -L1 SHEAR WALLS AT TELEVISION ROOM, BACK OF HOUSE LINE4 AND E 7/2/2020 AM 7/2/2020 ROUGH IN ELECTRICAL Jim Benner NOT APPROVED ( 383054 Notes: CORRECTIONS/ #21 -L5 NOT READY -UNSUPPORTED MC FEEDER -INCOMPLETE EMT CORRECTIONS/ #21 -L5 NOT READY -UNSUPPORTED MC FEEDER -INCOMPLETE EMT 7/2/2020 7/2/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL Notes: PARTIAL PPROVAL/#21 O.K. -L4 CORRIDOR HARDLID PARTIAL PPROVAL/#21 O.K. -L4 CORRIDOR HARDLID 7/8/2020 AM 7/8/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 262219 Notes: PARTIAL APPROVAL/#22 O.K. -WALL COVER BACK OF HOUSE OFFICES AND LAUNDRY Printed: Thursday, 14 October, 2021 5 of 13 1 SUPERION 7/10/2020 AM 7/10/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 16876 Notes: PARTIAL APPROVAL/#23 O.K. -L5 CORRIDOR HARD LIDS EXCEPT SOUTH 20 FT, AND EAST END 10 FT. -L5 LINEN & ELEC. RM. WALLS 7/14/2020 AM 7/14/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 123756 Notes: PARTIAL APPROVAL/#24 O.K. -L1 GUEST SUITES EXCEPT EAST END UNIT PARTIAL APPROVAL/#24 O.K. -L1 GUEST SUITES EXCEPT EAST END UNIT 7/24/2020 AM 7/24/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 82064 Notes: PARTIAL APPROVAL/#25 O.K. -WALL COVER Ll SOUTH 2 ROOMS EAST SIDE OF CORRIDOR AND SOUTH OF ENTRY EXCEPT AT PANEL 7/29/2020 AM 7/29/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 223377 Notes: PARTIAL APPROVAL/#26 O.K. -HARDLIDS L3 CORRIDOR AND ELEVATOR LOBBIES2-5 -WALLS IN MEETING ROOM, CLOSET, SHEAR WALL BAR STORAGE 7/30/2020 AM 7/30/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 57175 Notes: PARTIAL APPROVAL/#27 O.K. -543, 443, 343 -DOUBLE SHEAR WALLS LOBBY -WEST EXTERIOR WALL 8/4/2020 AM 8/4/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 575358 Notes: PARTIAL APPROVAL/#28 O.K. -WALL COVER PBX ROOM, TELECONF. & BOARDROOMS. 8/7/2020 AM 8/7/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 35493 Notes: PARTIAL APPROVAL/#29 O.K. -ALL WALLS AND HARDLIDS L2 -ALL WALLS Li SOUTH MEETING ROOM/CLOSETS -NORTH ENTRY VESTIBULE WALLS -L1 LAUNDRY AREA WALLS -ICE MACHINE CLOSET WALLS NOTE: -EXPOSE AND GROUND/BOND BLDG. STEEL Printed: Thursday, 14 October, 2021 6 of 13 r SUPERION Permit Inspections City of Tukwila 8/12/2020 AM 8/12/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 482944 Notes: PARTIAL APPROVAL/#30 O.K. -WALL COVER FITNESS ROOM COMPLETE 8/18/2020 AM 8/18/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 394950 Notes: PARTIAL APPROVAL/#31 O.K. -WALLS AND LIDS 143 -L1 EAST CORRIDOR HARD LID -HARD LIDS BOARDROOM, MDF, TELECONF. LOBBY, BAR 8/20/2020 AM 8/20/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 55505 Notes: PARTIAL APPROVAL/#32 O.K. -L1 HARDLIDS SOUTH OF ENTRY EXCEPT MEETING ROOM PARTIAL APPROVAL/#32 O.K. -L1 HARDLIDS SOUTH OF ENTRY EXCEPT MEETING ROOM 8/21/2020 AM 8/21/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 151939 Notes: PARTIAL APPROVAL/#33 O.K. -MEETING ROOM LIDS AND SOFFITS PARTIAL APPROVAL/#33 O.K. -MEETING ROOM LIDS AND SOFFITS 8/25/2020 AM 8/25/2020 ROUGH IN ELECTRICAL Jim Benner CANCELLED 42472 Notes: CANCELLED/ #34 9/8/2020 AM 9/8/2020 ELECTRICAL FINAL Jim Benner CANCELLED 13460 Notes: CANCELLED -NO POWER 9/8/2020 9/8/2020 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL Notes: PARTIAL APPROVAL/#35 O.K. -UG CONDUITS FOR BOLLARDS W BBQAREA 9/9/2020 9/9/2020 SERVICE Jim Benner PARTIAL APPROVAL 1 435 414 3256 Notes: PARTIAL APPROVAL/#36 O.K. -ENERGIZE SERVICE Printed: Thursday, 14 October, 2021 7 of 13 i4 SUPERION 9/9/2020 9/9/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL Notes: PARTIAL APPROVAL/#36 O.K. -COVER WALLS AND LIDS L5 GUEST LAUNDRY AND ELECTRICAL RM. 9/18/2020 PM 9/18/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#37 O.K. -L1 CORRIDOR AND POOL HARDLIDS 9/23/2020 PM 9/23/2020 ROUGH -IN ELECTRICAL Jim Benner NOT APPROVED Nephi - 435-414-3256 Notes: CORRECTION/ #38 -NOT READY 9/29/2020 PM 9/29/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#39 O.K. -T GRIDS L4 CORRIDOR, L1 KITCHEN & OFFICES 10/13/2020 PM 10/13/2020 ELECTRICAL FINAL Jim Benner CANCELLED Nephi - 435-414-3256 Notes: CANCELLED/ #40 -PER CONTRACTOR 12/23/2020 AM 12/23/2020 ELECTRICAL FINAL Jim Benner NOT APPROVED Nephi - 435-414-3256 / Level 5 Guestroom Notes: CORRECTIONS/ #40 -536 OPEN NEUTRAL -543 NOT READY -NO PANEL SCHEDULES -535 SPARK GUARD MICRO 12/29/2020 AM 12/29/2020 ROUGH -IN ELECTRICAL Jim Benner CANCELLED Nephi - 435-414-3256 Notes: CANCELLED -FINAL WANTED 12/29/2020 12/29/2020 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Nephi 435-414-3256 / Level 5 Guestroom Notes: PARTIAL APPROVAL/#41 O.K. -L5 UNITS EXCEPT 543 AND 536 12/30/2020 AM 12/29/2020 SERVICE Jim Benner CANCELLED Nephi - 435-414-3256 Notes: CANCELLED -FINAL WANTED Printed: Thursday, 14 October, 2021 8 of 13 iA SUPERION Permit Inspections City of Tukwila 12/30/2020 12/30/2020 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Nephi 435-414-3256 / Level 5 Guestroom Notes: PARTIAL APPROVAL/#42 O.K. -L4S EXCEPT 409 CKT.4 BREAKER -GEN. 3 x ATS & ELEVATOR DISCO 11 1/5/2021 1/5/2021 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 / Level 5 Guestroom Notes: PARTIAL APPROVAL/#43 O.K. -UNITS L4N EXCEPT 443 (NOT READY) 431, 436 (SPARK GUARD). NOTE: -COMPLETE PANEL SCHEDULES 1/12/2021 AM 1/12/2021 ROUGH -IN ELECTRICAL Jim Benner CANCELLED Nephi 435-414-3256 / Level 3 guestroom Notes: CANCELLED -FINAL WANTED 1/12/2021 AM 1/12/2021 SERVICE Jim Benner CANCELLED Nephi - 435-414-3256 / low voltage LV4 Notes: CANCELLED -ROUGH IN WANTED 1/12/2021 1/12/2021 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 / Level 3 guestroom Notes: PARTIALA PPROVAL/#43 O.K. -L4 CORRIDOR LIDS 1/12/2021 1/12/2021 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Nephi 435-414-3256 / Level 5 Guestroom Notes: PARTIAL APPROVAL/#43 O.K. -L3N EXCEPT 326 UC LTG. SW. AND COUNTER PLUG SWAPPED -1 BED PANEL SCHED. 1/13/2021 1/13/2021 ROUGH -IN ELECTRICAL Jim Benner CANCELLED Nephi 435-414-3256 / Level 3 guestroom Notes: CANCELLED -NOT READY 1/13/2021 1/13/2021 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Nephi 435-414-3256 / Level 5 Guestroom Notes: PARTIAL APPROVAL/#44 O.K.-L3S UNITS 1/14/2021 1/14/2021 ROUGH IN ELECTRICAL Jim Benner CANCELLED 1 Nephi - 435-414-3256 / Level 3 guestroom Notes: CANCELLED -NOT READY Printed: Thursday, 14 October, 2021 9 of 13 i1 SUPERION 1/14/2021 1/14/2021 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Nephi 435-414-3256 / Level 5 Guestroom Notes: PARTIAL APPROVAL/#45 O.K. -L2S UNITS 1/15/2021 1/15/2021 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 / Level 5 Guestroom Notes: PARTIAL APPROVAL/#46 O.K. -L2N EXCEPT 220, 226, 243. 1/15/2021 1/15/2021 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 / Level 3 guestroom Notes: PARTIAL APPROVAL/#46 O.K. -COVER CORRIDOR GRID CEILING L2 EXCEPT SOUTH. COVER L3N. -FITNESS ROOM SOFFITS, WALLS 1/21/2021 PM 1/21/2021 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#47 O.K. -L3S CORRIDOR 2 NORTHMOST T-GRID CEILINGS 1/21/2021 1/21/2021 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Nephi 435-414-3256 / Level 5 Guestroom Notes: PARTIAL APPROVAL/#47 O.K. -UNITS L1N EXCEPT 143 1/22/2021 AM 1/22/2021 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#48 O.K. -HOUSE LAUNDRY, LINEN STORAGE, LAUNDRY CHUTE ROOM CEILINGS 1/26/2021 AM 1/26/2021 ELECTRICAL FINAL Jim Benner CANCELLED Nephi - 435-414-3256 Notes: CANCELLED -ROUGH IN WANTED 1/26/2021 1/26/2021 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi -435-414-3256 Notes: PARTIAL APPROVAL/#49 O.K. -T BAR CEILINGS CORRIDOR L1N & L3S EXCEPT FURTHEST SOUTH 2/2/2021 AM 2/2/2021 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL Al Jeffs - 316-303-5123 Notes: PARTIAL APPROVAL/#50 O.K. -POOL SKIRT EQUIPOTENTIAL GROUNDING Printed: Thursday, 14 October, 2021 10of13 �1— i1 SUPERION Permit Inspections City of Tukwila 2/3/2021 AM 2/3/2021 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#51 O.K. -FITNESS ROOM CEILING 2/9/2021 AM 2/9/2021 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#52 O.K. -WALLS AND HARDLID POOL EQUIP. RM, RESTROOMS, VESTIBULE 2/11/2021 2/11/2021 ELECTRICAL FINAL Jim Benner NOT APPROVED RS Nephi - 435-414-3256 Notes: Rescheduled from 2/10. CORRECTIONS FOR ROOF/#53 -INCOMPLETE GROUNDING, WIRING, BUSHINGS 2/11/2021 2/11/2021 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#53 O.K. -COMPLETED CORRIDOR LIDS 52-5 2/16/2021 PM 2/16/2021 ROUGH -IN ELECTRICAL Jim Benner CANCELLED Nephi - 435-414-3256 Notes: CANCELLED -FINAL WANTED 2/16/2021 2/16/2021 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL RS Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#54 O.K. -OFFICE AREA, BREAK ROOM, RESTROOM 2/24/2021 AM 2/24/2021 ROUGH -IN ELECTRICAL Jim Benner CANCELLED Nephi - 435-414-3256 Notes: CANCELLED -FINAL WANTED 2/24/2021 2/24/2021 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL RS Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#55 O.K. -HOUSE LAUNDRY AND LINEN AREA/ROOMS 2/25/2021 2/25/2021 ELECTRICAL FINAL Jim Benner I NOT APPROVED I RS Nephi - 435-414-3256 Notes: CORRECTION/ #56 -NOT READY Printed: Thursday, 14 October, 2021 11 of 13 SUPERION Permit Inspe ion City of Tu k uii a 3/4/2021 3/4/2021 SERVICE Jim Benner PARTIAL APPROVAL Nephi - 435-414-3256 / low voltage 1V4 Notes: PARTIAL APPROVAL/#57 O.K. -ELEVATOR DISCOS#1 & #2 ROUGH -IN PARTIAL 3/5/2021 PM 3/5/2021 ELECTRICAL Jim Benner APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#58 O.K. -POOL NICHE LIGHTS PARTIAL 3/17/2021 PM 3/17/2021 ELECTRICAL FINAL Jim Benner APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#59 O.K. -LOBBY BUSINESS CENTER, FIREPLACE, COLUMNS, FLOOR BOXES, CONV. RECEPS -ELEVATOR LOBBY ROUGH -IN 3/18/2021 PM 3/18/2021 ELECTRICAL Jim Benner CANCELLED Nephi -435-414-3256 Notes: CANCELLED -FINAL WANTED PARTIAL 3/18/2021 PM 3/18/2021 ELECTRICAL FINAL Jim Benner APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#60 O.K. -ROOF TOP EQUIPMENT -LOBBY CORRIDOR & BATHROOMS -BOARDROOM PARTIAL 3/23/2021 PM 3/24/2021 ELECTRICAL FINAL Jim Benner APPROVAL Nephi - 435-414-3256 Notes: PARTIAL APPROVAL/#61 O.K. -RECEPTION, RESTORE, LUGGAGE, BUSINESS CENTER, FITNESS -ROOM 110 & LOBBY -L1 ALL NORTH OF LOBBY EXCEPT POOL 3/26/2021 PM 3/26/2021 ELECTRICAL FINAL Jim Benner NOT APPROVED Nephi - 435-414-3256 Notes: CORRECTION/ #62 -SPARK GUARDS REQ'D FOR RECEPS IN CABINETS OF BREAKFAST BAR PARTIAL 3/30/2021 3/30/2021 ELECTRICAL FINAL Jim Benner APPROVAL Nephi -435-414-3256 Notes: PARTIAL APPROVAL/#63 O.K. -ALL SOUTH OF LOBBY EXCEPT KITCHEN -BREAKFAST BAR AND LOBBY BAR Printed: Thursday, 14 October, 2021 12 of 13 rk SUPERION P7effmit Inspettions ���tm���o �v��� � kwAlal 3/31/20I1 3/31/021 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Nephl'435-414-3256 Notes: PARTIAL AppnovAL/#64 O.K.-STACK 43 'L3, 4,5100% 'L2EXCEPT CORRIDOR SOUTH 4/6/2021 AM 4/6/2021 ELECTRICAL FINAL Jim Benner NOT APPROVED mephi'43s'414'azso Notes: cuxnscTmws/wns -GROUND LIGHT POLES -HOT BOX FEED Toosxc'nouTso.uFCANNOT os/mCONTACT wyCONCRETE -FIRE PIT GFC|TOgEREADILY ACCESSIBLE -K.V.SEALS |m6x6BOXES 4/9/2021 pxx 4/9/2021 ELECTRICAL FINAL Jim Benner PARTIAL xrpnovAL wephi 435'414'3256 Notes: PARTIAL APpnUvAL/#66 / o.x.'mT[*sm -ALL EXTERIOR EXCEPT HOT BOX 4/13/2021 AM 4/13/2021 ELECTRICAL FINAL Jim Benner NOT APPROVED mcnhi-4ms4z4-32sn Notes: cnxnscTmws/w*r -CANNOT GET BONDING CONTINUITY ATPOOL WINDOW MULLIONS -LIFT TO BEPART OFPOOL BONDING SYSTEM 4/1*/2021 AM */14/2021 ELECTRICAL FINAL Jim Benner ArPxovco wephi *35'41*'325* Notes: APPRCmEry#68 ALL CORRECTIONS MADE Printed: Thursday, 14October, ZVZ1 13nf13 ,%A supsn/om City of Tukwila Department of Community Development 1/2/2020 RULON MUSSER 4795 OAKLAND ST DENVER, CO 80239 RE: Permit No. EL 19-0363 ELEMENT BY WESTIN 515 INDUSTRY DR Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/16/2020. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/16/2020, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, R4 Bill Rambo Permit Technician File No: EL19-0363 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 °PERMIT COORD COP? PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0363 DATE: 04/26/19 PROJECT NAME: ELEMENT BY WESTIN SITE ADDRESS: 515 INDUSTRY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: < to Building Division Public Works Fire Prevention Structural El Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable El (no approval/review required) DATE: 04/30/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved El Corrections Required (corrections entered in Reviews) DUE DATE: 05/28/19 Approved with Conditions n Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping El PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: December 22, 2020 Plan Check/Permit Number: EL19-0363 El Response to Incomplete Letter # Response to Correction Letter # 0 Revision # before Permit is Issued Revision # 1 after Permit is Issued 0 Revision requested by a City Building Inspector or Plans Examiner El Deferred Submittal # Project Name: Element Hotel Project Address: 515 Industry Drive Tukwila Washington Contact Person: Rulon Musser Summary of Revision: RECEIVED DEC 3 2020 TUKWILA PUBLIC WORKS Phone Number: 720.250.7675 Add Low Voltage Scope to Existing permit E19-0363 Valuation is additional $50,000 Sheet Num ber(s): Please reference the following list of plan pages for Low Voltage (if needed) E101, E102, E103, E104, E105,E300, E301, E302 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on td-P-30-001-d CAUsers\ Teminy \Desktop\Revi stem Submittal for Permit EL19-0363.doe Revised: August 2019 Home 1.;spafiof Contact Search L&I A-1, Index Help Mv 1.SH Safety & Health Claims & Insurance Workplace Rig.nts Trades & Licensing 4111114 Washington State Department of Labor & industries RELIANCE ELECTRIC INC Owner or tradesperson Barlow, Randall J Principals Barlow, Randall J, PRESIDENT Barlow, Randall J, SECRETARY Barlow, Randall J, DIRECTOR INCORP SERVICES INC, AGENT COX, THOMAS, PRESIDENT (End: 09/27/2016) WA UBI No. 602 850 908 PO BOX 840575 HILDA LE, UT 84784 435-874-1250 Business type Corporation License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. RELIAEI926RP Effective — expiration 01/20/2009— 03/23/2021 Designated administrator Barlow, Preston License type Electrical Administrator Bond Guarantee Company of North America USA, The Bond account no. 11130378 Active. Meets current requirements. License no. BARLOP*911B3 $4,000 00 Received by L&I Effective date 07/25/2016 06/09/2016 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Workers' comp Help us improve