Permit EL19-0390 - SHASTA BEVERAGES - ADD PANELS, DROPS TO EQUIPMENT, CONVENIENCE OUTLETS, RECESSED LIGHT FIXTURES
SHASTA BEVERAGES, INC MAINTENANCE SHOP 1227 ANDOVER PARK E EXPIRED 12/15/19 ELI 9-0390 \ »^ �~^�xx m�� Tukwila ~~�~� v�u o ��~^��Uoa Department 63UO�ou�hcenu�rgow|evo Tu�mi|a�vVashin��on981W �~ n*u"=xos'u��'��rn Parcel No: Address: Project Name: �of t 63UO�ou�hcenu�rgow|evord'Suite #10O Tu�mi|a,vVashinQton981W8 Phnne�2O6��1'367O Inspection Request Line: IO6'438'9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT 3523849072 Permit Number: I2Z7ANDOVERPARK E Issue Date: Permit Expires On: SHASTABEVERAGE, INC ' MAINTENANCE SHOP ELl9-O39O 5/22/ZO19 11/1O/2OI9 Contact Person: Name: NATIONAL BEVERAGE CORP 8100SVV10THITITE4000, PLANTATION, WA, 33324 19l6DOmA|RDRSW, SEAlTUE,WA, 98116 Contractor: Name: AFFIDAVIT ARTUURMANDREHAN License No: Lender: Name; Address: ''' ^'' Phone: (206)433-8997 Phone: Expiration Date: DESCRIPTION OF WORK: INSTALL 2 NEW PANELS, 8 DROPS TO EQUIPMENT, 16 CONVENIENCE OUTLETS, 2 RECESSED LIGHT FIXTURES, 21 SURFACE MOUNTED 4'FIXTURES. Valuation ofsingle family: $lOO Valuation ofmf/connm: $15'100l0 Type cfWork: TENANT IMP Fees Collected: $504,07 Electrical Service Provided by: PUGETSOUND ENERGY Water District: TUKVV|LA Sewer District: TUKWILA Current Codes adopted bythe City ofTukwila: international Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: ized Signature: National Electrical Code: VVACities Electrical Code: VVx[29046B: WA State Energy Code: 05 21 05 21 2017 2017 2017 2015 /� � Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and adee to t/e c9nditions Signature: Print Name: /', I&�»'J � �� Date: ^ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended o,abandoned for aperiod ofl8Udays from the last inspection. PERMIT CONDITIONS: l: 'ELECTRICAL PERMIT [0ND[F0N5~~* Z: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector ateach work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical wm/kshall beinaccordance with NFPA70 NEC, and requirements for electrical installations, Chapter 296-468VVACand the Washington Cities Electrical Code. 5: When any portion ofthe electrical installation is tobehidden from view bypermanent placement ofparts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any vio|adonofthepmv|siynsufnhee|ect/ica|codeo/ntherordinancesnfthe/uhsdiction.Permitsorre|ated documentation that presumes togrant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required, PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2V6)438'93S0 2100 ELECTRICAL FINAL 7003 ROUGH'|NELE[TR|[AL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWIL4 Community Development Department Permit Center 6300 Southeenter Blvd, Suite 100 Tukwila, WA 98188 \ 11\ \ ilaVv Site Address: VPS1 Tenant Name: Electrical Permit No. EL 0 Project No. Date Application Accepted: 6 Date Application Expires: \ (For‘office are only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** PROPERTY OWNER Name: ft:41Z taveubcie i.*- Address: I /47 Aocevee. fitoc. 49. City: 17.1404146. State: to& Zipi CONTACT PERSON — person receiving all project communication Name:erotv ,Vjekt is Address: teu ut itiata. 1;12. 4.41( City: piebittep State: Zip:qm 1 47 Phone: We Z. • • ef0(001 Email: et smille W ,, lit Ilf)thk, itecjit . L/....KA.. ig King Co Assessor's Tax No.: Suite Number: New Tenant: Floor: .....Yes K N° ELECTRICAL CONTRACTOR INFORMATION Company Name: Tec) Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ iq trb Scope (4.,Work (please provide detailed information): 445-1A5. 2 gev 1:414,4442 IL( Uwamace etteic, 4 / 1/15MC-A10 Liwit vgt 4 -4 -0:awl Will service be altered? ED Yes Type of Use: Type of work: El New 0 Addition Ei Service Change El Remodel 0 Low Voltage 0 Generator El Fire Alarm El Telecommunication Property Served by: lig Puget Sound Energy 0 Seattle City Light WAPermit Cente6Applientions-HandoutsWerme ApplicationsTorslElecatical Pent* Application Revised 1-17-19.does Adding more than 50 amps? 24, Yes No pr Tenant Improvement Temporary Service Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE o New single family dwellings (including an attached garage) O Garages, pools, spas and outbuildings o Low voltage systems (alarm) $180.00 $120,00 ea $60.00 ea AESEDEN11AL REMODEL AND SERVICE CHANGES Ei Service change or alteration $120.00 (no added/altered circuits) O Service change with added/altered circuits $100.00 number of added circuits $10.00 ea El Circuits added/altered without service change $60,00 (up to 5 circuits) El Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea o Meter/mast repair $80.00 o Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES o Temporary service (residential) $60 00 O Temporary service (generator) $90.00 o Manufactured/mobile home service $100.00 (excluding garage or outbuilding) El Carnivals $100,00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea \in A;;Nd t PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension oftime for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE .4 Y CTRICAL CONTRACTOR: Signature: Print Name:T%0 46tkh6 Day Telephone: Mailing Address: \et I (4' ret4640. '11 City Zip WAPernit CentalApplications-HandooldPemlit Applications \ PDFs\ Electrical Permit Application Revised I-17-19,docx Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 PermitTRAK ACCOUNT QUANTITY I PAID $04.80 EL19-0390 Address: 1227 ANDOVER PARK E Apn: 3523049072 $404.80 ELECTRICAL $385.52 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $385.52 TECHNOLOGY FEE $19.28 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17606 R000.322.900.04.00 0,00 $19.28 $404.80 Date Paid: Wednesday, May 08, 2019 Paid By: SHASTA BEVERAGES Pay Method: CHECK 598080 Printed: Wednesday, May 08, 2019 11:46 AM 1 of 1 SY57TA45 411 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT f QUANTITY I PAID PermitTRAK 148.97 EL19-0390 Address: 1227 ANDOVER PARK E Apn 3523049072 $99.27 Credit Card Fee $2.89 Credit Card Fee R000.369.908.00.00 0.00 $2.89 ELECTRICAL $96.38 PLAN CHECK FEE R000.34 .832.00,00 0.00 $96.38 PG19-0069 Address: 1227 ANDOVER PARK E Apn: 3523049072 $49.70 Credit Card Fee 51.45 Credit Card Fee R000.369.908.00.00 0.00 51.45 PLUMBING $48.25 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R17565 R000.322.103.00.00 0.00 $48.25 $148.97 Date Paid: Thursday, May 02, 2019 Paid By: NICHOLAS HEATON Pay Method: CREDIT CARD 002814 Printed: Thursday, May 02, 2019 11:59 AM 1 of 1 05 C0 CITY OF TUKWIL4 0aI7340000802374464500 Date: 85/02/20I9 11:59:24 4M CREDIT CARD SALE VISA CARD NUMBER: **********9037 K TRxN AMOUNT: $148.97 APPROVAL [D: 002814 RECORD #: 000 CLERK ID: kanclace X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: Type of ln pection Address: Ip Date Called: Special nstructio s: Date Wanted: 40 'Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: PA-vi rec-p6L5 uo6Lcizi=p 4 rujMth tAW-0 fee,9 .vi I. tw 6,___ Inspector: Ak REINSPECTION1FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 06 ighting Summary LGT-SUM 2015 Washi 0 c plia orms fo ngs includit dat R1 Revised August 201 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Tt Applicant Information. Provide contact information for individual wh can respond to inquiries about compliance form information provided. Name: Vik Com Company Address:W/Ngvore:14:7 p plicant Name: ‘146 plicant Phone: plicant Email: Project Description 0 New Building 0 Addition Da Fo uild • nt Use 0 2 _ Cit Cii(WIrd BUILCWG D;VI7! N rmt Alteration Plans Incl nclude PROJ-SUM fomi (included in envelape forms workbook) with lighting compliance forms. Building Additions Refer to Section C502.2.6 for additional requirements. RECEIVED CITY OF TUKWILA MAY 0 2 2099 Compliance Method Interior lighting Exterior lighting Ughting systems in addition area comply with all applicable provisions as a stand alone new construction project 0 Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance El Addition is combined with existing: For interior lighting projects, include new + existing inferior lighting fixture wattage in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form. nt*LAT1ifilltiEffiER Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures am replaced in some spaces, and 50% or more of the fixtures am replaced In others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for addi6onal requirements. No changes are being made to the Interior or exterior lighting systems and existing space uses and configuration are not changed. Ughting Power Interior lighting Parking garage erior lighting 0% or more of existing are replaced El El ess than 50% of existing are replaced mp and/or ballast replacement only — existing total wattage not increased 0 0 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5,2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. Less than 50% replaced- Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) New or moved lighting panel 0 Interior space is reconfigured - luminaires unchanged or relocated only New wiring or circuit - For interior fighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use 0 Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. ELli 31 n\ Interior Lighting - Space -By -Space Method LTG-INT-SPACE 2015 Washington State Energy Code Co Project Title: NW,' ITMAZb4erel . mbk-r. iop Date V 5 b 2('19 Calculation Area NpTE 9 0 0 Addition - 0 Addition stand alone + existing 0 Spaces where < 50% of a Spaces where a 50% of 0 luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type i • Standard 0 Additional Efficiency Package Option C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximunt Allowed Lighting Wattage NOTE 1 v. 44S, Z lz) Location (plan #, room #) Space Type Ceiling Height NOTE 2Area Gross Interior in fiz Allowed Watts per ftz Watts Allowed (wattslfiz x area) E Ito wonec ` ' 21 1 1.1,161 mC t lap lco Gllief' 1' Its4 S 4E1344 4( Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Total Area Retail Display w 7D LTG-INT-DISPLAY Allowed Watts Allowance from � t _ IA) Proposed Li ing Wattage NOTE 3 Location (plan #, room #) Fixture Description NOTE 4, 5. 6 Number of Fixtures Watts/ F' a NOTE 7 �� Watts Proposed etc/ tc .toti tx4 "kr,�ftx, L 2 qv e ten tab Ce YID t 4 �Y V ' 1, t ©'4 1 Proposed Retail Display Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1111 Interior Lighting Power Allowance Note 1- List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - list all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For lino voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance Is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the ovaraII existing building lighting systems to demonstrate compliance. Refer to C502.1. \ Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code Compliance Forrns for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: optimi ee167.44ef7 ige, i-Aitlf) Date Interior Lighting System Description Vx4 VD III VA100.7 - Me 1 , 1 IK*iop - hot r2Urfk* rftp, Lep Interior Lighting Power Allowance Method D Building Area Method 111 Space -by -space Method Select method used in project. Interior Lighting Contro s 0 All C405.2.1 - C405.2.8 Controls p C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) 0 Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. ,..... Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: ® 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA 0 C406.3 High Efficacy Lighting 0 Exterior Lighting System Description - Lighting, M©tor, and Electrical Permit Checklist, Pg. 1 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: /214b4911 PAA:90/Cier4 h'1bltr r /t lbr Date Gf Iz119 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents l3wtding Department Notes LIGHTING CONTROLS G405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken 1,.Z E. tva. C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves t-',as2 4 C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior Lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls ��� C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies 1 'TI C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50%-on, or serve a space eligible for automatic 100%-on per exception E lab Z• Ala C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% 47t" C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used � C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft gi� C405.2.4.2 C405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; Indicate toplight daylight zone areas on plans, include sq. ft; For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require specificppl g 9 per this section application lighting controls N% // C405.2.5 - Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method • i.i • • r 1 . a • . - .F MINIIMEMEIMI Revised August 2016 2015 Washington State Energy C�de Compliance Fomis for Co menial Buildings Inluding R2, R3, R4 over 3 stories and all R1 Project Title: 4If4. Date The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documonts Location in Documents Building Department Notes /VA C405.2.5 - Item 3 Hoteumetei guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room 1414 C405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting mitor C405.2.5 - Item 5 Lighting for non - visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control *ca C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space, Indicate method of manual lighting control and applicable automatic lighting confrOl if C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures t function as both normal and emergency means of ress illumination; Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0,02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicatemethod of automatic shut-off control /4104 C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For budding facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed openina/closing time; For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 C405.2.5 Area controls - Master control switches and circuit power limit Indicate 1003 ' of mastertrol s ' ch(es) intended to control multiple independent switches; Circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automat' trol is loaded beyond 80% C406.4 Enhanced digital lighting controls To complywith additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) C405.13 C408.3 Lighting system functional testing If claiming lighting system commissioning exemption provide supporting calculation; Identify applicable commissioning documentationu ent per Section C408 or eligibilitt_for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response • • I 2015 Washington • . • I • 0. . State Energy Code Cornplianoe Forms for Conimercial Buildings including R2, R3, R4 over 3 stones and all R1 Revised August 2016 Project Title: *I.iblit' VA3)eak.16;7 gbii-t eCO Date The following information is necessary to check a permit appbcation for m ian with lighting, motor, and electrical requirements the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY • C405.4.1 C405.4.1 C405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) e 44/A C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). gikr C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with tamps that have this efficacy rating (min 95% to comply with option). Lighting Power Calculation - Indicate compliance path taken C405.4.2.1 Building Area Method Complete required compliance forms - proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans C405.4.2.2 Space -By -Space Method Complete required compliance forms - total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable I.Vpir C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method EXTERIOR LIGHTING POWER & EFFICACY gikt C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category Vilis. Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ ‘,iittr C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule 141‘ C405.5.2 Exterior lighting power calculations Complete required compliance form - proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director February 5, 2020 David Kehle 1916 Bonair Dr SW Seattle, WA 98116 RE: Request for Expired Permit Reinstatement — EL19-0390 Shasta Beverages, Inc. — Maintenance Shop — 1227 Andover Park E Dear Mr. Kehle, This letter is in response to your request to re -open the already expired permit EL19-0390. The Building Official has reviewed your letter and determined that the City of Tukwila Building Division will not be re -opening the permit. A notice was mailed to the designated contact for this permit (David Kehle) a full month ahead of expiration (letter was dated and mailed November 1, 2019) which provided two options to keep the permit in good standing. The first was to continue construction and have an inspection and the second option was to submit for extension at least (7) days in advance of the expiration date. The request we did receive was received (7) days after the actual expiration of the permit. This is why your request for extension has been denied. In order for work to continue and inspections be conducted, a new permit will need to be issued. To do this, complete and submit a new application with two copies of drawings and documents. As with the original submittal of the permit, this submittal will need to be made in person. If you wish to discuss the determination made, please contact the Building Official directly at 206 431- 3675. Sincerely, aQ Bill Rambo Permit Technician File: Permit No. EL19-0390 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98 8 • 206-4 00 • We i e: TukwilaWA.gov davitd ke le January 15, 2020 Request for PerAxtension # I Current Expiration Date: 1 /5.16f Extension Request: H, I .ApproVCCI for Denied wide e \plink) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: Mr. Jerry Hight RE: Shasta Beverage Inc, 1227 Andover Park E Tukwila, WA 98118 Tenant Improvement Permit Extension EL19-0287 OC Lab Permit Extension EL19-0390 Maintenance shop Permit Extension D19-0177 Catwalk Dear Mr. Hight, e;r44 " days Signature/Initials I am in receipt of letters from Bill Rambo, permit tech, that the above permit will have expired. I am asking for an extension to this permit for the following reasons: 1. There are ongoing owner revisions due to construction inadequacies that need to be resolved that will impact the permits. QC Lab had a revision resubmittal and has not been re approved. 2. The maintenance shop electrical inspection was dropped by Shasta due to a personnel change _recently impacting call for inspections. 3. There are sequences of projects that need to be completed prior to having final inspections occur due to limitations on space in the facility ( ie build this first and then build the next which takes longer to complete). This has impacted the Catwalk construction and therefore there was nothing to inspect. This was scheduled to be constructed this next week, so extension on this is critical. 4. There are on going City concerns that are being addressed delaying construction and inspections. This impacts the QC room and Glycol Room 5. There are some cost implications of the construction which impact cash flow for construction. I believe these are adequate to allow for the extension of the permits. Sincerely, 1916 Bonair Drive S.W. Seattle, WA 98116 RECEIVED CITY OF TUKWILA JAN 1 5 2070 PERMIT CENTER (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch,com City of Tukwila Department of Community Development 11/1/2019 DAVID KEHLE 1916 BONAIR DR SW SEATTLE, WA 98116 RE: Permit No. EL19-0390 SHASTA BEVERAGES, INC - MAINTENANCE SHOP 1227 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/15/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/15/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL19-0390 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 architect May 2, 2019 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: RE: Mr. Jerry Hight Shasta Beverage Inc, 1227 Andover Park E Tukwila, WA 98118 Tenant Improvement Maintenance Shop Air and Electrical Dear Mr. Hight, RECEIVED CITY OF TUKWILA MAY 0 2 2019 PERMIT CENTER As the Design Professional In Responsible Charge, I have reviewed the attached permit submittal, drawings and calculations, for the Maintenance Shop located under the metal mezzanine, prepared by the Plump Group. I have included the lighting energy code form showing compliance. I believe these are adequate for permit submission. Please accept for permit review. Sincerely, David Kehle ELM-. 031v 1916 Bonair Drive S.W. Seattle, WA 98116 (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch.com •", PERMIT COORD GOP? PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0390 DATE: 05/02/19 PROJECT NAME: SHASTA BEVERAGE INC - MAINTENANCE SHOP SITE ADDRESS: 1227 ANDOVER PARK E X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # --Revision # after Permit Issued DEPARTMENTS: \1A1 Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator a PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/07/19 Structural Review Required REVIEWER'S INIT ALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 06/04/19 Approved with Conditions 111 Corrections Required Denied (ie: Zoning Issues (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff1nitias 12/18/2013 CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 432-3670 FAX (206) 431-3665 E-mail: tukplan@ci.tuicwila.wa.us STATE OF WASHINGTON) ) ss. COUNTY OF KING Permit Center/Building Division 206 431-367o Public Works Department 206 433-0179 Planning Division 206 432-367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: 1)19-0 58 EL-19 -0q0 r A [please print name] , states as follows: 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.2.7.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.2.7.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.09o, I consider the work authorized under this permit to be exempt under number and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I mighOtherwise have under state law in any decision to engage an unregistered contractor to perform constructioi/work. 4:--rfier/ er s' en d sworn to before me this ay of G- al - Ns' AR PUBLICin and for the State of Washington Ki, County Name as commissioned9. /-'01//•e' +aid e Residing at , 20 19. My commission expires: (2,5 (.46/(d-i- 18.27.090 Exemptions. The registration provisions of this 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; to. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to Bearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed chapter do not apply to: by a registered contractor; II. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; t5. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; t6. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid'electrical contractor's license under chapter 19.28' RCW that employs a certified journeyman electrician, a certified residential 'specialty electrician, or an electrical trainee meeting the. requirements of chapter 19.281 RCW to perform plumbing work that is incidentally, dire4tly, and immediately appropriate to the like -in -kind. replacement of'a. household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while'performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. DEMOLITION NOTES GENERAL NOTES ELECTRICAL SYMBOLS LIST 1. DEMOLOION WORK SHALL BE PERFORMED ACCORDING TO THE ARCHITECTURAL PLANS. 2. ALL MATERIALS, LIGHTING FIXTURES, CONVENIENCE OUTLETS, WIRES, CONDUITS. JUNCTION BOXES AND ALL OTHER DEVICES SHALL CONFORM TO MATCH THE EXISTING CONDITIONS AND EQUIPMENT ON THE JOB SITE, UNLESS OTHERWISE NOTED. 3. REMOVE, REROUTE AND REWIRE EXISTING FIXTURES. RECEPTACLES AND JUNCTION BOXES AND PROVIDE NEW BRANCH CIRCUITS. PANEL FEEDERS, AND DEVICES AS SHOWN ON THE PLANS OR AS REQUIRED FOR A COMPLETE OPERABLE SYSTEM, IN FULL ACCORDANCE AND COMPLIANCE WITH ALL APPLICABLE CODES. 4. ALL EQUIPMENT WHICH IS DISCONNECTED AND REMOVED SHALL BE RETURNED TO THE OWNER. 5, FURNISH AND INSTALL ALL NECESSARY CONDUITS, WIRES, JUNCTION BOXES, BLANK COVER PLATES, ETC. AT ALL LOCATIONS AFFECTED BY RELOCATION OF OUTLETS. 6. WHERE INTERRUPTION OF A CIRCUITS FEEDING EXISTING EQUIPMENT OCCURS DUE TO NEW WORK, THIS CIRCUIT SHALL BE REHABILITATED AND MADE CONTINUOUS FROM PANEL TO LAST EXISTING OUTLET. 7. THE CONTRACTOR SHALL REUSE EXISTING CONDUIT RUNS AND HOMERUNS WHERE POSSIBLE ACCORDING TO CODES HAVING JURISDICTION, PULL NEW WIRES AS REQUIRED. ALL OTHER EXISTING UNUSED CONDUITS AND WIRES SHALL BE REMOVED BACK TO LAST EXISTING OUTLET. 8. UPDATE PANEL DIRECTORIES AT EXISTING PANELS TO REFLECT NEW WORK. 9. THE CONTRACTOR SHALL VERIFY THE CURRENT IN EXISTING FEEDERS AND BRANCH CIRCUITS THAT ARE AFFECTED BY THIS PROJECT PRIOR TO ADDING LOAD TO EXISTING CONDUCTORS, BREAKERS: PANELS, TRANSFORMERS OR SWITCHGEAR. NOTIFY ARCHITECT IMMEDIATELY IF ANY EXISTING EQUIPMENT IS FOUND TO BE OVERLOADED OR WILL BECOME SO IF NEW LOAD IS ADDED. 10. THIS DRAWING IS BASED ON EXISTING DRAWINGS AND OWNER SUPPLIED INFORMATION. THERE HAS BEEN NO VERIFICATION OF PRECISE LOCATIONS, WIRING OR OPERATION OF EXISTING EQUIPMENT. CONTRACTOR SHALL VERIFY ALL JOB CONDITIONS PRIOR TO BID. CONTRACTOR SHALL THOROUGHLY EXAMINE AND VERIFY POINTS OF CONNECTION, ACCESSIBILITY. SIZES. LOCATIONS, ELEVATIONS, ETC. EXISTING CONDITIONS FOUND UNACCEPTABLE OR IN VIOLATION OF CODES AND AUTHORITIES HAVING JURISDICTION SHALL BE CORRECTED. 11. CONTRACTOR SHALL PERFORM ALL VERIFICATION, OBSERVATION,TEST, AND EXAMINATION WORK PRIOR TO THE ACTUAL CONSTRUCTION. HE SHALL ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE ARCHITECT LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. 12. ADDITIONAL LABOR AND MATERIAL REQUIRED TO PROVIDE A COMPLETE AND OPERABLE SYSTEM IN ACCORDANCE WITH CODES AND ALL AUTHORITIES HAVING JURISDICTION NOT LISTED N THE WRITTEN NOTICE TO THE ARCHITECT SHALL BECOME PART OF THE CONTRACTOR'S WORK JUST AS IF IT WERE INDICATED AND IMPLIED ON THE PLANS. ABBREVIATION AFF AFG AIC BC BKBD CO E,(E) ECP EG EM ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMP INTERRUPTING CURRENT BARE COPPER BACKBOARD CONDUIT ONLY EXISTING ENVIRONMENTAL CONTROL PANEL EQUIPMENT GROUND EMERGENCY FLA FSP GFCI G, GND, GRD IG LCL N,(N) NF NL FULL LOAD AMPS FIRE SUPPRESSION PANEL GROUND FAULT CIRCUIT INTERRUPTER GROUND ISOLATED GROUND LONG CONTINUOUS LOAD NEW NON -FUSED NIGHT LIGHT R.(R) SCC SAD SMD UNO VL WP WT REMOVE RELOCATE SHORT-CIRCUIT CURRENT SEE ARCHITECTURAL DRAWING SEE MECHANICAL DRAWING UNLESS NOTED OTHERWISE VERIFY LOCATION WEATHERPROOF WATER TIGHT 1. ELECTRICAL CONTRACTOR SHALL VERIFY VOLTAGE, HORSEPOWER RATINGS, EXACT LOCATIONS OF ALL ELECTRICAL AND OTHER EQUIPMENT PRIOR TO ANY ROUGH -IN. IF DISCREPANCIES ARE NOTED, ADVISE THE ARCHITECT/ENGINEER IMMEDIATELY. 2. SEE RELATED WORK SHOWN ON CONSTRUCTION DOCUMENTS PREPARED BY THE ARCHITECT TOR WORK AND MATERIALS TO BE FURNISHED AND INSTALLED UNDER THIS WORK. 3. LOCATE LIGHT FIXTURES SO AS TO AVOID ALL EQUIPMENT FURNISHED BY OTHER TRADES. COORDINATE ALL ASPECTS OF INSTALLATION PRIOR TO ROUGH -IN. 4. THE ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2014 EDITION OF THE NATIONAL ELECTRICAL CODE, AND ALL LOCAL CODES HAVING JURISDICTION. 5. ALL LIGHT FIXTURES SHALL BE FURNISHED TO MATCH WITH THE CEILING TYPE IN WHICH THEY ARE INSTALLED. PRIOR TO BID, CONTRACTOR SHALL VERIFY CEILING TYPE INDICATED ON ARCHITECTURAL DRAWINGS. LOCATE ALL LIGHT FIXTURES AS SHOWN ON THE REFLECTED CEILING PLAN, 6. ALL ELECTRICAL EQUIPMENT EXPOSED TO THE WEATHER OR DAMP AND WET AREAS SHALL BE WEATHERPROOF AND HAVE UL LABEL CONSISTENT WITH APPLICATION (NEMA 3RJ. 7. CONTRACTOR SHALL FURNISH AND INSTALL AN AUXILIARY JUNCTION BOX AT ALL LOCATIONS WHERE A RECESSED LIGHT FIXTURE IS SHOWN WITH MORE THAN EIGHT (8) WIRES CONNECTING OR RUNNING THROUGH IT. SEE NEC 370-6 AND 410-11. 8. CONTRACTOR SHALL OBTAIN THE EQUIPMENT SUPPLIER'S DRAWINGS AND INFORMATION RELATIVE TO THIS PROJECT. HE SHALL IIRLIZE THIS INFORMATION FOR EXACT POINTS OF CONNECTION. NO INSTALLATION SHALL BE PERMITTED IN VIOLATION OF MANUFACTURER'S RECOMMENDATIONS. 9. ALL ELECTRICAL EQUIPMENT SHALL BE NEW AND U.L. LISTED. 10. LIGHTING FIXTURE CATALOG NUMBERS, VOLTAGES, AND LAMP TYPES ON THE FIXTURES SCHEDULE SHALL BE TREATED AS MINIMUM REQUIREMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION OF ALL VOLTAGES, NUMBERS, LAMP TYPES AND MOUNTINGS. 11. CONTRACTOR SHALL FURNISH AND INSTALL A GROUND WIRE N ALL CONDUITS. GROUND WIRES MAY NOT BE SHOWN, BUT SHALL BE INCLUDED IN THE ELECTRICAL CONTRACTOR'S BASE BID AND SIZED PER NEC ARTICLE 250-94 AND 250-96, OR AS NOTED ON DRAWINGS. 12. FACILITIES SYSTEMS: AT NO TIME SHALL ANY WORK BE DONE THAT MAY INTERRUPT THE OPERATIONS OF ANY EXISTING FACILITIES WHICH AFFECTS PEOPLE OR EQUIPMENT OUTSIDE THIS SCOPE. IF, IN THE OWNER'S OPINION THERE IS NO POSSIBLE WAY TO AVOID SUCH DISRUPTION. THE CONTRACTOR SHALL CONTACT APPROPRIATE AUTHORITIES, SUBMIT A PLAN FOR APPROVAL TO THOSE RESPONSIBLE. OBTAIN ALL AGREEMENTS, AND THEN COMPLY WITH THOSE AGREED UPON PROCEDURES IN ALL ASPECTS, COORDINATION OF OUTAGE OF ANY SYSTEM SHALL BE EXECUTED WITH SUFFICIENT ADVANCE NOTICE SO AS TO MINIMIZE THE IMPACT OF THE INTERRUPTION OF SERVICES. 13. CONTRACTOR TO TAG/IDENTIFY ALL CONDUCTORS FOR EQUIPMENT INSTALLATION. 14. CONDUIT AND DUCT RUNS ARE SHOWN SCHEMATICALLY. BUILDING CONDITIONS WILL DETERMINE THE ACTUAL RUNS. 15. THE CONTRACTOR MUST VISIT THE SITE PRIOR TO SUBMITTING A BID AND INCLUDE ALL REQUIREMENTS FOR EXISTING FIELD CONDITIONS IN HIS PRICE. 16. ALL SWITCHES AND RECEPTACLES SHALL BE SPECIFICATION GRADE AND 20 AMPERE MINIMUM. WALL - PLATES SHALL BE TYPE 302 STAINLESS STEEL COLOR OF DEVICES TO BE SELECTED BY ARCHITECT. 17. ALL WIRING SHALL BE INSTALLED IN RACEWAYS. 18. ALL WIRING SHALL BE COPPER, #12 AWG MINIMUM, TYPE THWN AND RATED FOR 600 VOLTS. 19. RACEWAYS ALLOWED: RIGID METAL CONDUIT (REQUIRED IN MECHANICAL, ELECTRICAL AND EQUIPMENT ROOMS), EMT, STEEL FLEXIBLE CONDUIT (MAXIMUM LENGTH SHALL BE 6 FEET) AND PVC COATED METAL CONDUIT (REQUIRED UNDERGROUND AND IN EXISTING SLABS). MINIMUM SIZE HOMERUN SHALL BE 3/4", OTHERWISE I/2' MINIMUM ALLOWED. ANY RACEWAYS WITH 6 OR MORE CONDUCTORS SHALL BE 3/4" MINIMUM (INCLUDING GROUNDING CONDUCTOR). ALUMINUM FLEXIBLE CONDUIT SHALL NOT BE USED. FLEXIBLE CONDUITS EXCEEDING 6 FEET IN LENGTH SHALL INCLUDE AN GREEN INSULATED CODE -SIZED EQUIPMENT GROUNDING WIRE, PROPERLY BONDED AT EACH END TO MAINTAIN GROUNDING CONTINUITY AS REQUIRED BY CODE. 20. FIRINGS: GALVANIZED STEEL TYPE; SETSCREW TYPE. 21. SLEEVES: PROVIDE SLEEVES FOR ALL RACEWAYS AND/OR WIRING THROUGH FIRE -RATED WALLS, CEILINGS AND CONCRETE OR STEEL FLOORS. SEAL SLEEVES, AFTER INSTALLING RACEWAYS, WITH APPROVED FIRE -RATING MATERIAL OF EQUAL RATING AS ORIGINAL FIRE -RATING. CABLES AND WIRING THROUGH SLEEVES SHALL BE SEALED ON BOTH ENTRIES. 22. ALL EXISTING AND NEW PANELBOARDS SHALL HAVE TYPE -WRITTEN DIRECTORIES ADDED BY THE CONTRACTOR INDICATING EXISTING CONDITIONS, PRESENT MODIFICATIONS AND NEW WORK. 23. SEAL ALL PENETRATIONS THOUGH FLOOR OR FIRE RATED WALLS WITH FIREPROOFING MATERIAL THAT HAS AN EQUIVALENT FIRE RATING AS THAT OF THE EXISTING CONDITION. 24. THE ELECTRICAL WORK SHALL BE GUARANTEED FOR A PERIOD OF NO LESS THAN ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER. ANY WORK, MATERIAL OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE UPON WRITTEN NOTIFICATION AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. 25. ALL CONDUIT ONLY (C.O.) SHALL HAVE A PULL WIRE OR ROPE. 26. PROVIDE THE OWNER WITH ONE SET OF COMPLETE ELECTRICAL REPRODUCIBLE DRAWINGS AT THE COMPLETION OF THE JOB SHOWING ACTUAL DIMENSION AND CIRCUITS. 27. ALL BROCHURES, OPERATING MANUALS, CATALOGS. SHOP DRAWINGS. ETC. SHALL BE TURNED OVER TO THE OWNER AT JOB COMPLETION. 28. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDITION. 29. PATCH, REPAIR, AND PAINT TO MATCH SURROUNDING CONDITION, ANY AREA DAMAGED IN THE COURSE OF THE ELECTRICAL WORK. CLG. WALL FLR. DESCRIPTION FUSED SWITCH, SEE AS SHOWN - V.L. NON -FUSED SWITCH, SIZE AS SHOWN - V.L. TIME CLOCK - 7 DAY, SKIP -A -DAY FEATURE WITH MANUAL BY-PASS SWITCH MOTOR OUTLET - IDENTIFICATION SURFACE MOUNTED PANEL 120/208V, 3-PHASE, 4-WIRE MAIN SWITCHBOARD OR POWER DISTRIBUTION BOARD FLEXIBLE CONNECTION /)'CP 'PROVIDE CORD AND PLUG CONDUIT CONCEALED ABOVE CEILING OR IN WALLS CONDUIT UNDER SLAB OR BELOW GRADE. 3/4" MINIMUM HASH MARKS INDICATE QUANTIFY OF #12 WIRES IN CONDUIT, EXCEPT NO HASH CONDUIT RUN EXPOSED , 5Y MARKS DESIGNATE 2 #12 WIRES. OTHER CONDUIT AND WIRE AS INDICATED , 55' HOMERUN TO PANEL "A", CIRCUITS # 1 AND #3 - T - TELEPHONE 3/4" C.O. - U.O.N. T1 = I-1 /4" C.O.: T2 = T-I /2" C.O. INDICATES PLAN NOTE NUMBER "1", SEE PLAN CONDUIT STUB OUT, 3/4" MINIMUM - SEE PLANS FOR NOTES 0 FO LIGHTING FIXTURE OUTLET - VERIFY MOUNTING WITH FIXTURE SCHEDULE lel HEI EXIT LIGHT FIXTURE - ARROWS AS SHOWN (90 MINUTES MINIMUM) DUPLEX RECEPTACLE AT+18" / rpDUPLEX MOUNTED ABV. COUNTER 143 DOUBLE DUPLEX/ DUPLEX RECEPTACLE AT +18"= CONTROLLED NL NIGHT LIGHT 0 CEILING -MOUNTED PHOTOCELL SENSOR 0 JUNCTION BOX AT+18" WALL MOUNTED U.O.N GROUND FAULT INTERRUPTING RECEPTACLE/MN= GFCI MOUNTED ABOVE COUNTER / WP DUPLEX/DOUBLE DUPLEX RECEPTACLE, FLUSH FLOOR MOUNTED ®CL DUPLEX RECEPTACLE, CEILING MOUNTED DEDICATED RECEPTACLE, 208V. 10 DEDICATED RECEPTACLE, 480V, 30 (N) PANEL 'HMS' VOLTS:277/480V PHASE: 3 A.I C. RATING: 42,00D AMP MAIN: MLO MOUNTING: SURFACE WIRE: 4 BUSSING: 225 AMP LOAD • A -VA B-VA C-VA BKR CT' CT BKR A -VA 13-VA C-VA ' LOAD LATHE M 12008T - j , 20/3 1 2 50/3 4400' sM WELDER --- M 1200 - 3 4 - 4400 M -- ---. M 1200 - 5 6 - - 4400 M -- 7 8 20/1 1146 L 1ST LEVEL LIGHTING 9 10 20/1 1496 L 2ND LEVEL LIGHTING 11 12 20/1 SPARE M 45KVAXFMR1T2' 13 14 50/3 14868 15 16 - 14708 M ' 17 18 - " 15420 M --- PHASE TOTALS: 21614 21804 21020 64438 =TOTAL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 78.0 78.7 75.8 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS: 1.25 X 2642 = 3303 VA Cr-CONTINUOUS LOADS, OTHER: 1.25 X 0 = 0 VA M=MOTOR LOADS (INCL LOST): 1.00 X 61796 2t 61796 VA LARGEST, VA: 0.25 X 12000 = 3000 VA R=RECEPTACLES: 1ST10K: 1.00 X 0 = OVA BALANCE: 0.50 X 0 = 0 VA K=KrrCHEN LOADS: QTY: 0 0.65 X 0 = 0 VA N=NONCONTRAJOUS LOADS, OTHER: 1.00 X 0 = 0 VA NOTES: (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 68099 VA = 81.9 AMPERES (N) PANEL 'LMS' VOLTS:120/208V PHASE: 3 A.I.C. RATING: 22,000 AMP MAIN: 150A MOUNTING: SURFACE WIRE: 4 BUSSING: 225 AMP LOAD ' A -VA B-VA IC -VA BKR CT CT BKR A -VA B-VA C-VA ' LOAD 208VSHOPRECEPT R 3000 30/2 1 2 20/3 -"'' SPARE -- R ,, 3000 - 3 4 - ` ._- SHOPRECEPT R [._.. j 720 20/1 5 6 - -. - SHOP/DFFICERECEPT R 1620 20/1 7 8 AC-1 M 120E ' 20/2 9 10 M ' ' 1200 - 11 12 AC$ M 1200 i - 20/2 13 14 -- M ,, .. 1200 - 15 16 SHOPRECEPT R ','; 1 720 20/1 17 18 5012 '. SPARE SHOPRECEPT R 720 - 20/1 19 20 - -- SHOPRECEPT R 720 20/1 21 22 302 -. 3000 '. M TEMP WELDER SHOPRECEPT R /20 20/1 23 24 - "�:,�„ 300E M ----- PHASE TOTALS: 6540 9120 6360 22020 =TOTAL CONNECTED LOAO,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 54.5 75.9 53.0 "DEMAND LOAD CALCULATION: L=LIGHTING LOADS: 1.25 X 0 = 0 VA C=CONTTNUOLS LOADS, OTHER: 1.25 X 0 = 0 VA M=MOTOR LOADS (INCL LGST): 1.00 X 10800 = 10800 VA LARGEST, VA: 0.25 X 12000 = 3000 VA R=RECEPTACLES: 1ST10K: 1.00 X 10000 = 10000 VA NOTES: BALANCE: 0.50 X 1220 = 610 VA K=KITCHEN LOADS: QTY: 0 0.65 X 0 = 0 VA N=NONCCNT1N000S LOADS, OTHER 1.00 X 0 a 0 VA (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 24410 VA = 67.8 AMPERES LIGHTING FIXTURE SCHEDULE 1 SINGLE POLE SWITCH AT 48" U.O.N. - V.L. #2 DOUBLE POLE SWITCH AT +48" U.O.N. - V.L. SYMBOL FIXTURE TYPE WATTAGE VOLTAGE LAMPS DESCRIPTION MANUFACTURER CAT. NO. FINISH MOUNTING REMARK 13 THREE-WAY SWITCH AT +48" U.O.N. - V.L. f4 C 45 277 INTEGRAL 40K LED 2'x4' LED RECESSED MOUNTED LIGHT FIXTURE W/TROFFER LRHONIA LIGHTING EPANL 2X4 4000LM 80CRI 40K MINI MVOLT EIOWCP NLTAIR2 RIO WHITE RECESSED LED DRIVER 0-10V DIMMING TO 10% FOUR-WAY SWITCH AT +48" U.O.N. - V.L. "a" INDICATES OUTLET CONTROLLED AT+48" U.O.N. (PROVIDE SEPARAT SWITCH FOR EACH DESIGNATION) MOTOR CONTROL TOGGLE SWITCH H.P. RATED CE 45 277 SAME AS TYPE "C" EXCEPT WITH EMERGENCY LED DRIVER, AND WITH MIN. OF 90 MINUTES BATTERY BACK-UP. CEILING -MOUNTED MOTION/OCCUPANCY SENSOR I=1 D I10 277 INTEGRAL 152' LED LINEAR HIGHBAY 40K LED LIGHT FIXTURE EIKO WHITE SURFACE LED DRIVER 0-10V LLH-5C-50K-U-1S DIMMING TO 10% SPECIFICATIONS; INFORMATION ADJACENT TO CALL.OUT INDICATES HORSE DENOTES MECHANICAL EQUIPMENT SEE MECHANICAL DRAWINGS FOR EXACT POWER (H.P.) AND VOLTAGE RATING lal DE 110 277 SAME AS TYPE "D" EXCEPT WITH EMERGENCY LED DRIVER. AND WITH MIN. OF 90 MINUTES BATTERY BACK-UP. EIPORC MOUNT JUNCTION BOX WITH BLANK COVER PLATE 6" ABOVE ACCESSIBLE CEILING FOR MODULAR FURNITURE POWER POLE BY OWNER. "P' INDICATES POWER SUPPLY, "C" INDICATES DATA AND TELEPHONE SUPPLY 1-0-1 F 49 277 INTEGRAL 40K LED 4' LED GENERAL LNEAR LIGHTING SERIES 0C4-LED SERIES 2-OCE-LED-5000L-DIM 10-MVOLT-30K WHITE SURFACE LED DRIVER 0-10V DIMMING TO 10% 4/0 PULL BOX iT; FE 49 277 SAME AS TYPE "E' EXCEPT WITH EMERGENCY LED DRIVER, AND WITH MIN. OF 90 MINUTES BATTERY BACK-UP. 3 3aD DIMMER/ OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCHING AT+48" (120 VOLT) OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCH NG AT +48" (120 VOLT) XE 2.3 277 LED EXIT SIGN WITH 90 MINUTES BATTERY BACK-UP. LITHONIA LQMSW 3 R120 EL N WHITE UNIVERSAL Jab OCCUPANCYAUTOMATIC WALL SWITCH SENSOR WITH BI-LEVEL SWITCHING AT+48" (120 VOLT) (E) 6 @ 4"C., 4 #500 MCM & 1 #4/0 GND TO (E) POWER UTILITY FACILITIES WoltOREPONAI FILE C P„ m' 33-mit ?; �:. .-..,1( ae11K...-W.. 4 L (E) 277/480V, 3 0, 4 WIRE MAIN SERVICE "MS' 65KAIC (E) 277/480V, 3 0, 4 WIRE FULLY BUSSED 7 Tg -i9 N 7'C 4#3/0 THHN CU + 1 #2 GND 11 II II J O� J (E) (E) (E) CWP UFER (N) \200A `PROVIDE MATCHING BREAKER 50A 3P I"C.3#1 THHN CU+ 1#4GND 45KVA, XFMR 72' PRI:480V, 30, 3W-Delta SEC:208V, 30, 4W-Wye 1 #4 GND I� ) 3OA �) 3POA r ♦ ♦ r TO (E) LOAD/CIRCUITRY TO REMAIN PROTECT IN PLACE 1 1 /2C.4#1 THHN CU+ I#6 GND MAX. L=I0' VD%=NEG SEPARATE PERMIT RE:f;2UIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION E002 ELECTRICAL DETAILS E100 FIRST FLOOR POWER PLAN E102 FIRST LIGHTING PLAN E103 SECOND FLOOR LIGHTING PLAN iabD DIMMER/OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH BI-LEVEL SWITCHING AT+48" (120 VOLT) Y DATA/TELEPHONE OUTLET, WALL -MOUNTED I DATA OUTLET, WALL -MOUNTED SHEET LEGEND E001 GENERAL NOTES, SYMBOLS LIST, LIGHT FIXTURE/PANEL SCHEDULES & SLD 114 ii J DEG.1 SINGLE LINE DIAGRAM NOTES SI. S2. 53. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDUITS ALL NEW. CONDUCTOR SHALL BE COPPER. ALL EQUIPMENT AND CONDUITS SHOWN ARE EXISTING UNLESS NOTED OTHERWISE. S4. VISIT SITE BEFORE BIDDING PROJECT TO SEE ALL EXISTING CONDUITS. QUALIFY ANY EXISTING CONDITIONS IN BID THAT WERE FOUND DURING SITE VISIT. IF NO SITE VISIT IS DONE IT WILL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO DO PROJECT COMPLETE PER PLANS WITH NO EXTRA COST 5 201$ 4 0 1 uJ _ a 4T PLUMPGROUPB a division of Plump Engineering, Inc. 914 E. KATELLA AVENUE ANAHEIM. CALIFORNIA 92805 P (714) 385-1835 F(714) 385-1834 www.pklmpgroup.com =:::PROCON C. 1,4ene DEVELOPMENT INC. - COPYRIGHT 0 a .44 -J a. 0 PROCON DEVELOPMENT J 4522 Katella Ave. Los Alamitos, CA 90720 s REC._ I.1 CITY OFT(,',,II , MAY 0 2119 PERMIT C6\LrE s� ;.: 1st VIEWEgra-FE 4 12A1970 -Ease HAY 2 0 20 of TUkvale UILOING DIVISION EL 19- 03d10 Stamp: 1 0 0 le PIIM,p a DV nwmua = Plump = ENc=uS a E=Rkhap ump®.ir .Ina i C"'PNmp EMirominp. GNuRIl,c.', r: un Runt Richard Plump o I.000dan: PIMP Enpnse4np, Reason: I amine author al this Cohn= Info: (714) 385-1835 Data 201903.26 16:15.330T00 - w CO p cement LLJ 03/26/2019 z_ Z Q N LLJ LL I LLI Z Z Z 1227 Andover Park E. TUKWILA, WA, 98188 REVISIONS FOR CITY SUBMITTAL 3/4/19 Need Menace: SP Dale; Scab: Prat Numbe: 190209?1 0 J 1-- J J 0 m >- LU F- 0 Z J LLJ LJJ 0 0 LE- ) LJJ LU 0 V) J LJJ a_ LJJ X LL SHEET NUMBER E001 0 0 CONCEPT, 0 0 0 DOCUMENTS 0 cc 0 REFER r C0 IRO LCHEDULE TO SCHEDULE �� � LUMINNRE MANUFACTURER'S® EARTHQUAKE 0.1P. (4) AT CORNERS ATTACH METAL SCREW FIXTURE WHIP FROM JUNCTION BO% 6 FT. LONG MAX LUMINNRE REFER(QO IN RE REFEf ' PER FIXTURE WITH SHEET �, , LUMINNRE NINJ STRUCTURE CORNER) 3 TWIST SUSPENSION WIRES ATTACHED TO (TYP. 0 EACH MINIMUM (TYP.)sensor+ 5 3/ 47,www.plumpgroup.eom ilh I 20"Ia 1111r IIP II ill IIII NOTE: WALL RATING IF PANEL OCCURS IN PROVIDE ENCLOSURE TO MATCH() FIRE RATED WALL. CONTRACTOR SHALL FIELD VERIFY WITH ALL LOCATIONS. STEEL STUD BUILDING STRUCTURE914 ENGRAVED NAMEPLATE ON FRONT PANEL TYPEWRITTEN CIRCUIT DIRECTORY LOCATED ON INSIDE FACE OF DOOR HINGED, LOCKABLE AND FLAT DOOR PLUMP division ANAHEIM, (714)385-1835 4 E. 10P of Plump KATELLA Engineering, CALIFORNIA F(714) AVENUE 92805 385-1834 E $applications, Inc EiK Catalog name ' Catalog number i.ieF� . LED LINEAR.SWAY r DESCRIPTION A costeffeaive solid state LED solution for highbay replacing up to 250 watt and 400 watt fluorescent luminaires. PE 130low - >130 Ipw uhra•high, ePocienq delivers superior and HID, savi u to 6016 of ene n8 p• Universal 0-10V driver for continuous dimming - is items feature pre -Installed adjustable microwave LISTfNC5 - UL Listed for damp locationsDesign Lights Consortiums Premium Qualified -meets for the highest DLC qualification maintenance ?GRFDRMRNCE� • Rated lifetime L70 >700,000@40°C (104°F) • 4WOK SOOOKCCT - CBI: 80e ELECTRICAL - Input voltage:124277V,347-480V • Dimmable powersupply(0.101.0 • Driver efficiency:>85% • Power Fattor: >.9 - THD: <20% THERMAL • -22°F to 122°F630°C to 50°C) operating temperature CONSTRUCTION • Heavy gauge steel body with welded frame construction twisting and bowing . Diffuse frosted acrylic lens to control glare (standard) clear lens for higher light output (sold separately) • 10ft. Y-toggleaircraflcable mounting hardware , Built-in 2.5kV surge protection WARRANTY ' 5 year limited warranty: see eiko.com for warranty ORDERING INFORMATION •ENTRANCE Mndet." Package-- 1C-110W 14000 (comments : voltage r . _ WPlawd d :sae and lowboy HID fixtures and A.multi-lamp 4'-- performance overfluorescent costs LIM IC UM 2c occupancy t Lr' 3C therequirements for of cacy andMCHTECTURALIlumen -'' 1. I. 4C. LLIrSi APPLICATIONS • Warehouses • Indoor Recreational - Manufacturing Plants Facilities • Distribution Centers • Cold Storage • Grocery Stores • Big Box Retail resists • Gymnasiums • Service Repair Centers or optional included Compila�®nt C R details EXAMPLE:LLH1C-50K-U-1S ccT VoMsye sensor- . hn DLC - ' ••■PROCON DEVELOPMENT !NC. G, ,t d",,. PROCON DEVELOPMENT 4522 Katella Ave. Los Alamitos, CA 90720 FLUSH LOCK HANDLE AND MECHANISM w. ����► 11111 G II BOLT TO STRUCTURE, BOTH SIDES, WITH ACOUSTICAL COUNG TIE (np.) 114" DIAMETER BOLTS, THREE PER SIDE AND FRAME , AS REQUIRED Stamp: R v. A. p N. o `ufg�2A,?y= ' s ; �34218 F' -"e "ets1ER``��4`�� s/DNA L , • 0311919/20 2X4 LIGHTING FIXTURE DETAIL SCALE: SCALE: -ACT. NOT TO SCALE NOT TO SCALE MAIN SERVICE CONDUIT SLEEVE PER SEAL ENTIRE ANNULAR SPACE A Ol :WILA, WA-13 E MEZZANINE 3 MO; ra? g R gpp��pag�r'� U R.A�Y p p o _ _ 4aA 3 yh :RP &911 i 8w 0 EQUIPMENT "MSB" SPECIFICATIONS SECURED IN WALL AROUND SLEEVE/CONDUIT INTERFACE WITH FIRE RETARDANT n 'a2W L1 VouX1 ARK.4MOK J yy tzppaa77V ' 1S•OccupancySensor PER SPECIFICATIONS LLH: LED Linear Highbay 9C-223w2o0001m K - 265w. 3SD00 Im f S01t. 5WOK J 341dkOJ Manic) • No sensorSEALANT PANELBOARD sr._ SC • 321 W: 42,000 Im - EikO USA:1430Q52,2217 I .iKO Canada: i 888.4141Sl }': o CDT ,r SERVICE FEEDER (l } � 4, PHASE BUSES " r- NEC 250.28 LES SEAL ENTIRE ANNULAR CONDUIT PER LED GENERAL LINEAR «4.LED i Catalog Number 0C4-LED LIGHTING SERIES ----------- SERIES LED GENERAL UGHTING LINEAR CURVE LUMINAIRE Project Name (SURFACE OR SUSPENDED MOUNT) ripe EQUIP. BONDING JUMPER, Q /— SPACE AROUND SPECIFICATIONS NEC250.102(C) m SLEEVE/CONDUIT INTERFACE STAND 'DWALL BUILDING WALL/FLOOR P ° z � WITH NON -SHRINK WATER COPPER SERVICE . GROUNDING CONDUCTOR, MINIMUM ELECTRODE SIZE � 0 J TIGHT SPECIFICATIONS GROUT PER a AS SHOWN ON GROUNDING ELECTRODE CONDUCTOR #4/0 CU CONDUIT SLEEVE PER UL LISTED FILL, VOID SCHEDULE R `INTERSYSTEM BONDING SPECIFICATIONS SECURED IN WALL IN OR CAVITY MATERIAL FOR USE IN THROUGH (1ST), FIRESTOPS PER i '-..-"e"--------__ NERM 250 9ION SPECIFICATIONS am ) ` 1 • BUILDING STEEL, NEC 250.52(2) MIN 1 I P. e' 3000 4000 5000 8000 ® DRIVEN 5/8"X 10' COPPER CLAD SLAB REBAROR#4 UFERGROUND, SEAL ENTIRE ANNULAR CONDUIT PER 50,004NRs (SPACED 10' APART) NEC 250.52(3) SPACE AROUND SPECIFICATIONS 30 40 49 82, APPMCanaN. • :ea • le.nirtedan kir aeon?da tayuud • Laarydada and swage arms • IkMa icoman dice bdklings. scads. hospilab. pudic Tamar areas. parking Ck • Design for general or task Bald' g and Mara • Etonantal alternative 10 meet OW and Naar ten aemma • Retail ass er bog norm stole lama i 1 i 1 SLEEVE/CONDUIT WITH NON INTERFACE WATER FIRE -RATED WALL BUILDING WALL/FLOOR ♦ -SHRINK L e TIGHT GROUT PER COLD WATER PIPE, NEC 250.52(1) SPECIFICATIONS SERVICE GROUNDING SYSTEM SCALE: 4 SCALE: PROOUCTFEATURE • viewed IDordure Igntapaead� lordpolo50.000roarsofeto170• Frosted entailed lens detains Lidlyelftidu rnvrareIgM • tested to 1M-19 and LM-80slaaads • grebe segr is Ideal for commercial and rdusha maces reoumg general Illummalic • Ikm1'day 20 euge tied diced mranda lot CUratd0 eta LPOe condoms • S,abe Inr dry and damp en.rannrms •Pretreated Wan Imeld aan phachate cocas to ertn sinner part adieson • Salta For surface a a&wended MVltMg DIAGRAM NOT TO SCALE CONDUIT PENETRATION PANEL NOT TO SCALE 3 $EYED NOTF� fD N G C)1 11E - ....... f LJ air L L• i vl•uYl-11 2 2019 f LFD'. • Pamed h b-glas Caked Mite enamel • Inrvidtml of cadlnueus Iv; morn fx4 • at reflector comes in white fo y rdk[km flit • tighlveght Mien enables ease inssta'Ia»an ernes Ina ached enuded ddna ens d the 0C4-ED gamer me Sat fCallerc by the Or1IO% -Freer% cal be s,mmd pm 'walled tarn dayhgd Weeding conmis. Onanarcy LED Cho aid dowers HOW emcel vdumeec 1pd,rd b any enactment LEDs ore saced sensors.endyal Mver pan.N®aabc madadlea antis include Lehr. Wale m bard dear amr*Nery lade aro LED Image Men final le Metalled and pattered a. Aravaaan, and °ten. the Wamtgwer-MS-EMIa5 &net Hign Frecuency Demon lbe lens on be easily rammed yahoo the use d look, making me unit wadable and Senses Is a he voltage senses Ina tars lgtny on and al based on=loamy. and tat %Lay naml lnd. old alms at wenn macaw daylight i5 available II delalla n'UIiM vN firer 1gb Inguen:; {SW eleeanagMlt waves and Ina DC ear amdC. MS FMI051s MAW bennd rind PFIIEOWASIE- NIRO engines lard in ore OCa-LED ate rased al 80. al ax are lenses am Hach iron nem � amikhle krnwpe tens 3o7DK 3slIX COOK and saat. Raludaroksledm LN 79 r. ad1M•80aa'XMIQS. Re LEDs de also baled to a 3-sta sworn eraees to acme* WMUfl CONTROL- Nay lMWeslanedmaC' toted by as OC DepalmM m western Cola from NumtoMane awe Or" o ruled b Is and Canadian samads fd tors:towel1?0-2M lrpd,pcdma leas than MS -man haw a maw form cl.D ELECTRICAL Powered M IegM1 aWdy alawR NroM pond lE0 ddrcrs Wick ore ratM IVARR -Y - laded g,.ao. YAMAl/1 umgBdsMee; Meanly — maw •the ROLLED comes standard Mm 0,10r 1% ammhc a moo Mix 2gN ••**PROMr a Tar°,nn Also awisdeit Laren dimmigoptimm.Cadualacwy'lerammeroermatbiliy y DAYI• • •©' �A,,1E REVISIONS Sheet Title: ELECTRICAL DETAILS FOR CITY SUBMITTAL 3f4f,9 f MAY 0 1 TYPCAL FOR WOOD AND METAL STUD ROUGH —IN. E RECEPTACLE ,II i' C OUTLET BOX PERMIT CENTER 2 PLASTER RINGS NOT SHOWN, COORDINATE RING GROUNDING In 1 MI DEPTH TO BE FLUSH IL - LUG SCREW la. a 11 - WITH FINISHED SURFACE• UNLESS NOTED 5 U� OTFERWISE. B 9 --- —_ - ,,�.� 3 GROUNDINGEXPIR.F...., _ LOCATE ALL OUTLET BOXES IN ACCORDANCE • //��_. �-��._.`, , f __ Eta t / (GREEN) ,1 3 m_ ,=ra ,," "- - WITH ARCH AND MECH. . •.. .� aTff r/ e .. - �11� ;'�t �- - - DRAWINGS AND WITH ALL APPLICABLE SHOP DRAWINGS. G /'—� ; , 1 ©E�-L glll TAPPED HOLE IN BOX. c-- 3 Ordering Information: Example:2-OC4-LED-4000L-DIM10-MVOLT-30K (TYP.) 4 OUTLET BOXES ON OPPOSITE SIDES OF WALLS "�� 4 a.4 LEA R I ... ff L_-- rr 1. l_ I .-__• q���yy OR PARTITIONS IN THE SAME STUD SPACE MUST a r — T "�i:r.D BE SEPARATED BY A MIN. OF 6" HORIZONTAL DISTANCE. 'FP 0 i �� ettquallitiMalaillik- NxlgaSIN $ THE WRENS OREMIaO VOLTAM ear Ca SIERREMT OTHER OPTIONS Or4OxY orb 4'ra,ife se Palo mob may Kr Mao % 6 memte MNIIa ,edn limns e-e erg,,,„, Ton WA,4mbosxxr. oar• da•MOM aznaxaoo, u.a, aaa -ISeee mrg 'coma wa.Iwaro Ixass.Snpt•nyM' lymnsn am.ISNaI'arog1° Maladag Lx,srn War e4 �� a GROUNDING SCREW-#1032x3/8" 0CW1 vHai r Kam MIS orlon USA uMa�nAmnia m•d.0 VI"' q . yes .��, 5 ELECTRICAL BOXES INSTALLED IN FIRE RESISTANT WALLS OR PARTITIONS SHALL COMPLY WITH IBC itt SLOTTED HEXAGON HEAD, WASHER FACE SCREW. (TYPICAL) aagLla0la Lr-& rrYamorFaa a>v Fuu�' SM- bWral 9m Box Fwe Ma• sadorademu away t0 ��Ip__' �• per _ 11 _ �' 714,3.2. STRIP INSU L. AND LOOP BASE - VI WEC. FO ;z- CONDUCTOR AROUND (TYP) w p�.g� �NFPA %NEC - 6 INSULATED THROAT EMT CONNECTOR. PHASE SCREW WITHOUT 70 70 CUTTING CONDUCTOR OR - --- - BRANCH CIRCUIT FEEDER I o I ,- yzt. D� : 7 CADDY FASTENER, THROUGH STUD CAB_E�CONDUIT SUPPORT. 8 ADJUSTABLE BAR HANGER. PROVIDE ADDITIONAL WIRE NUT TERMINATION EQUAL TO NEUTRAL. WIRE NUT (TYPICAL) HAY 2 0 7019 CRy of Tukwila BUILDINGDIVISION ^O�GM1OO°° SP oat&: [MC CABLE] 5 4 g TYP:CAL DEVICE JUNCTION BOX. CONDUIT TYP. FOR ALL C • GROUNDING CONDUCTOR SHALL BE CONTINUOUS SO THAT REMOVAL OF DEVK E WILL NOT INTERFERE WITH �O OR�INUITY. EL I gigs Prd.ct Number. 1902097 SHEET NUMBER SCALE: 7 TYPICAL ROUGH DETAIL SCALE: SCALE: E002 LIGHTING FIXTURE CUT SHEET NOT TO SCALE —IN Q TYPICAL RECEPTACLE GROUNDING DETAIL NOT TO SCALE NOT TO SCALE 0 cc su se ce 0 z ou 0 V // I Q ® i PLUM,yw a division 914 ANAHEIM. P (714)F(71) 4 E. 385-1835 www.plumpgroup.com of Plump KATELLA # �Aw�Ay. OUt GAP Engineering, AVENUE CALIFORNIA 92805 F(714) 385-1834 Inc. GENERAL NOTES: GI. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS BOXES, MISC. FIRINGS, ECT, FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION AND C.E.C. 12016). G2. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE AND OFFSET 24" MINIMUM. G3. ALL PENETRATIONS THROUGH FIRE WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. G4. ALL UNDERGROUND CONDUITS SHALL BE PVC. SCHEDULE 40, MINIMUM 3/4"C. RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR. G5. WORKING CLEARANCE SHALL BE AFFORDED TO ALL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC 110.26. G6. WHERE A SHARED NEUTRAL CONDUCTOR LS USED FOR MULTIPLE BRANCH CIRCUITS, CONTRACTOR SHALL GROUP CIRCUITS TOGETHER IN PANEL AND PROVIDE A MANUFACTURER FURNISHED HANDLE -TIE TO SIMULTANEOUSLY TRIP ALL OF THE CIRCUITS SHARING THE NEUTRAL. G7. VOLTAGE DROP IN ACCORDANCE WITH ENERGY CONSERVATION CODE 505.7.3. G8. ALL 120V CIRCUIT LENGHTS GREATER THAN 100 FT SHALL BE INCREASED TO # 10 AWG AND TO #8 AWG WHEN GREATER THAN 160 FT. INCREASE CONDUIT SIZE FOR 40% FILL. ::::PROCON DEVELOPMENT INC. Ge,..... 0 O O 0 PROCON DEVELOPMENT 4522 Katella Ave. Los Alamitos, CA 90720 b I 9 e e e e O O O O O O LMS-17 4ROV _ 1 JP 3P 0 F WELDER 0 KEY NOTES: Sfamp: ,RDA. p I 2 HOMERUN TO PANELBOARD CIRCUITS 8. RECEPTACLES SHOWN ARE TO BE TIED/CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS DESIGNATED. (TYPICAL FOR ALL HOMERUN CIRCUITS) ELECTRICAL CONTRACTOR TO PROVIDE SERVICE DISCONNECTS. 0 LMS-7 4 .cLSi�1i • ~ " o z Po q 34218 p c� ,off.ONA L1i - .4S xP. 0 ° ° C 0 _ _.. , 0 7 only•gma W Rimera DM'us. E=RbnrEpWmpein oom. Engineering, O Plunp Engineering, Inc.", CN=Riiaid Plump Plumpllipr,pa�Ergllaen^9. Reason: I am to next delis on �71) 3051895 1e18:11.0708r COPIER O f O — LMS-19 LMS-17 E C OS 0 G EQUIPMENT KEY NOTES: O OFFICE 101 �— L IJ 03/26/2019 I " I TORRANT SAND BLASTER MAINTENANCE "` I el B I CLAUSING LATHE • LMS-9 11 C DRILL PRESS 1P D OSIER 435 POWER VISE 411V • Z Z I D E BAND SAW III s N N W • 208V 11) LMS-13,15 . F COMPRESSOR TANK UCOMPUTER DESK • C `'' 17 U LMS-19 OFFICE LMS-70 •0 J LMS H 3 GRINDING WHEELS • — 102 CC w • O SZ _ U b D I� _ Z s° 1 1 < Q_ Cs‘ • LMS-7 I o Z Q 45 Q 0 C � p I _. I (TYPICAL) 2 J < O 0 < = Q N SZ V N D — ~ HMS-2,4,6 :: LMS-23 WEL ER 1"C3#8CU+1#10CUGND _ B 480V f— ,, F ❑ (TYPICAL) 1 3P [ V 3P �A 480V A 3P i WELDER ,r LMS-50 REVISIONS HMS-1,3, 5 % Tr FOR CITY SUBMITTAL 3/4f19 IP EXPiJ!. I DEC. 15 2019 0 A LMS-23 0 H H H U * LMS-21 LiZ Q LMS-1,3 o 30A " D_ fY b 3/4"C-2#10+1#10CUGND JP 208V $ LMS-5 LL ) p T2 0 RECEIVED CITY OF TUKWILA 0 CL XFMR'T2 —/ \—(N) PANEL'HMS' MAY 0 2 2019 1 DEF LI PIec I 0 (N) PANEL'LMS' IOC/ PERMIT CENTER WAY 2 6 2019 OIn of Tukwila IL cn ___ — _ ... .. __. _____.-_. .._.__. . ..- ...._..... .... ._ ._.._..... . _.. I \ScDale:SP PLAN "pi NORTH tp E)._P i'` 0 3 9 WRLINf31MI61Cp1..�L_ Cr) Ce LL Project Nlmog•C di cde: Protect Number. 198209E SHEET NUMBER FIRST FLOOR POWER PLAN 1 E 1 00 1 /4"=1'-0" 0 • 0 N 0 0 u iz 5 J 28 0Rg Yh eLL /�_\\ ,\�O_.//1 Q 1 EIIiIII; Jf PLUMPGROUPB a division 9 1 ANAHEIM, P (714) 4 4 E. 385-1835 www.plumpgroup.com of Plump K It Engineering, A T E L L A AVENUE CALIFORNIA F(714) 385-1834 92805 Inc. GENERAL NOTES: G1. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS. CONDUCTORS, BOXES, MISC. FITTINGS, ECT, FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION. G2. SUBSCRIPTS IN LIGHTING PLAN DENOTES SWITCH. EXAMPLE: 2a, 2 DENOTES CIRCUIT NUMBER AND a DENOTES SWITCH THAT CONTROLS CORRESPONDING LIGHTS. G3. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE 111 LUX) A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT-CANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM -TO -MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. ::::PROCON „,,..,. DEVELOPMENT INC. KEY NOTES: 1 2 3 4 HOMERUN TO PANELBOARD CIRCUITS & RECEPTACLES SHOWN ARE TO BE TIED/CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS DESIGNATED. (TYPICAL FOR ALL HOMERUN CIRCUITS) ROUTE CONDUITS OVERHEAD & PROVIDE NECESSARY SUPPORT PER CEC. EXIT SIGN AND EMERGENCY LIGHT LIGHTING SHALL BE PROVIDED WITH A BATTERY BACK-UP UNIT WITH MINIMUM OF 90 MINUTES AND MUST BE WIRED AHEAD OF ANY SWITCHING DEVICES. ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A CONSTANT HOT CONNECTION TO THE CHARGING LEAD. PROCON DEVELOPMENT 4522 Katella Ave. Los Alamitos, CA 90720 ❑ Up I XE •_ O 0 �z�o�� -% Stamp: G oR D. A. Toz 07yya p 34218 �Frs ONA LT E t�''\�crr. 4@ 9/20 I ❑ ❑ XE F_ E F --we•F F ( __,— -_. 0 _ in,OS/ ////I/� . WPM P1'Wawa Pune DN' CUS E=Rc srtl IurmCpNa.Pan, O•'pWmp Engiroe,inD. Irt.'. Richard Plum L 2rdEnNRuEp p ILaatirc m Pump Eneineennp, Reason' am Ma auNadtl,s mamm Date: 2019.0Content Info:T261385�1836 1616:31.0707 ❑ F ❑ OS - _ F 1 ^ • • C / MAINTENANCE r �� LU 03/26/2019 i100 v OFFICE / F FE F lot z Q • 1 z %XE OFFIC / Q `N IV w i OCCUPANCY % —102 ❑ ElSBJSOR (TYPICAL) I ❑ C _ J F 0•F I W I •F SZ DU w°° a co 1 < o_ 0. F (TYPICAL) F 3 4 FE F Z N Q O f— i 1 Q Z c Q o Cn a` sz _ N l— ❑ ❑ ❑ -- 3 (TYPICAL) FE F OS F F -Frei REVISIONS FOR CITY SUBMITTAL • EXPIRED »XE XE ; _ DEC.15 2rn9 Q U o_ C�J� L HMS-8 "T �� Ate_ YM.Na�'tsid`isileb J 1 FLU 1- CD �(N) PANEL 'HMS' EL '0390 0 0 0 RECEIVPD LL CITY OF TUKWILA MAY 0 2 2019 PER 11 t1[�`�� L.L MSc, Manager: SP Dole: hi'RE.. 1- POP- _ 1 ESOMPLIANCE VNTh i j MPAP. 70 • NEC i Mt 2 O 2� I :Try of T. ukwiI 1 WILDING DIVISION Stile; A" I)11 prdea Number: 1902097 N SHEET NUMBER FIRST FLOOR LIGHTING PLAN 1 E 1 02 1 /4"=1'-0" RIGHTS RESERVED (\�Q//, C92 \ ` PLUMPGROUP$ a division 9 1 ANAHEIM, P (714) 4 4 E. 385-1835 www.plumpgroup.com of Plump K OP Engineering. A T E L L A AVENUE CALIFORNIA 92805 F(714) 385-1834 Inc. GENERAL NOTES: GI. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS, BOXES, MISC. FIRINGS. ECT, FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION. G2. SUBSCRIPTS IN LIGHTING PLAN DENOTES SWITCH. EXAMPLE: 2a, 2 DENOTES CIRCUIT NUMBER AND a DENOTES SWITCH THAT CONTROLS CORRESPONDING LIGHTS. G3. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE 1 FOOT-CANDLE 1 LUX) A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE ((1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL ILLUMINATION LEVELS SHALL BEPERMIREDTO DECLINE TO 0.6 FOOT-CANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM -TO -MIN MUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. :=::PROCONe.,f,,,.,,. DEVELOPMENT INC. KEY NOTES: 1 2 3 4 HOMERUN TO PANELBOARD CIRCUITS & RECEPTACLES SHOWN ARE TO BE TIED/CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS DESIGNATED. (TYPICAL FOR ALL HOMERUN CIRCUITS) ROUTE CONDUITS OVERHEAD & PROVIDE NECESSARY SUPPORT PER CEC. EXIT SIGN AND EMERGENCY LIGHT LIGHTING SHALL BE PROVIDED WITH A BATTERY BACK-UP UNIT WITH MINIMUM OF 90 MINUTES AND MUST BE WIRED AHEAD OF ANY SWITCHING DEVICES. ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A CONSTANT HOT CONNECTION TO THE CHARGING LEAD. PROCON DEVELOPMENT 4522 Katella Ave. Los Alamitos, CA 90720 — -- DN LANDING ,) X E 0 I ° Stamp: R a A. p _ DE D D - , !L Ogi `� ` 0 0 u+ a -0 e, 'Pic34,,%, c. Cr" ONA LT L E�'\�Exp. 03/19/20 _ I 1 0 III t _ _ I Ipea PY mmw Plump ON: c=us E=RichrdplwrpOpeia cap oesunu Enainemirp. Inc?% CN=R°Aard Rung Richard Plumply:�Enpineeenp,, Realm: I amM autiv ul thisCo Calla ,rmp11 38-1a 35 DC a319..113.26 15:16:53.0100 D D D `� _�of OS LLJ 03/26/2019 Z MEZZANINE D 200 DE D Z Q Q N w �41 XE C I 3 (TYPICAL) i® XE w SZ OD OCCUPANCY SENSOR (TYPICAL) D 0 D LL co r Z 1 Q Q_ o' LLJ O 3 f7— J ` Q Q = o a Q T. SL N I- D D (TYPICAL) 3 4 1 1 DE REVISIONS Sheet Rile: SECOND FLOOR LIGHTING PLAN FOR CITY BUBMrTTAL Sans 0 0 \� ) ►`l -1' . HMS 10 1 DEGAS S 2019 f 'I XE (--I 31,1 LANDING • RECEIVED CITY OF TUKWILA MAY 022019 —_— PERMIT CENTER -.... ..._ 0 FOP. ' I PqNCE VJITi- HAY 20 20E 19 City of Tukwils pUILDING DIVISIOri NORTH r�' EL'q`031S Pry. SP Dale: ProlectNun°°r 1902097 SHEET NUMBER SECOND FLOOR LIGHTING PLAN 1 E 1 03 1 /4"=1'-0"