Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL19-0411 - BOEING / VAULT 28 - ADD GENERATORS, SWITCH GEAR, FEEDER BREAKERS, TRANSFORMER WITH PANEL ETC
BOEING -VAULT 28 8123 EAST MARGINAL WAY SOUTH ELI 9-0411 Parcel No: Address: ~^ vx ^ ' "°"^U ~ U~ x n Tukwila Department ofCommunity Development G30BDouthcente,Boulevard, Suite #10O Tukwila, Washington 98188 Phone: 206~431,3670 Inspection Request Line: ZOG'43O-935V Web site: http://www.TukwilaWA.gov 3324049002 Project Name: BOEING -VAULT28 ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL19-04ll 7/9/2U19 l/5/ZO20 Owner Name: Contact Person: Name: Contractor: Name: License No; Lender: 8OE|NGCOMPANY THE POBOX 3707NyC20'59PROPERTY JJHUOnTON Phone: (206) 817-8442 gOIPOVVELAVE SE, RENTON.WA, 98057 FOYGROUP CORPORATION Phone: (206)937-0150 2400NvV80TH ST, STEll8'SEA ||LE, WA, 98117 FOYGRGC863LK Expiration Date: 6/12/2020 DESCRIPTION OF WORK: INSTALL TEMPORARY 500KW PORTABLE GENERATOR. INSTALL 1 600KW GENERATOR, REMOVE 100A MTS/45KVA TRANSFORMER & PANEL. REMOVE (4) D100 LIGHTS & GROUND CONNECTIONS, INSTALL (1) 27KV SWITCH GEAR WITH (3) 200DA BUSSES, (1)200DA TIE BUS, 11 FEEDER BREAKERS, INSTALL (1) 100A MANUAL TRANSFER SWITCH/(1) 4KVA TRANSFORMER WITH PANEL, INSTALL (3) EXIT SIGNS AND (5) M/13 FIXTURES. REINSTALL (4) D100 LIGHTS ETC Valuation nfsingle family: $0.00 Valuation ofmf/comm: $2'550,080.00 Type of Work: GENERATOR Fees Collected: $23,91937 Electrical Service Provided by: 5EATTLECITY LIGHT Water District: SEATTLEJUNW|iA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signatur amidto ,t/ ci)1/ Date: 7- 9-fq I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development peand agree to the conditions attached to this permit. Signature: Print Name: Date: _7— This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 7003 7002 7001 ELECTRICAL FINAL ROUGH -IN ELECTRICAL SERVICE UNDERGROUND/SLAB CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. -04-111 Project No. Date Application Accepted: fr;*-10-1C( Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.; 8123 E Marginal Way S, Tukwila, WA 98108 Site Address: Suite Number: Tenant Name: Boeing " Va_ I+ ZS' PROPERTY OWNER Name: Boeing Address: 8123 E Marginal Way S City: Tukwila State: WA Zip: 98108 CONTACT PERSON — person receiving all project communicatjon Name: IT Hjorten Address: 901 Powell Ave SW City: Renton State: WA Zip: 98057 Phone: 206-817-8442 Fax: Email: jerry.h@foygroup.net New Tenant: Floor: 0 Yes [XI „No ELECTRICAL CONTRACTOR INFORMATION Company Name: Foy Group Address: 901 Powell Ave SW City: Renton State: WA Zip; 98057 Phone: 206-817-8442 Fax: Contr Reg No.: 601930924 Exp Date: 12/31/2019 Tukwila Business License No.; BUS-0994437 Valuation of Project (contractor's bid price): $ 2,550,000.00 Scope of Work (please provide detailed information): Install (1) Temporary 500kw portable generator, Install (1) 600kw generator, remove 100a MTS/45kva transformer and panel, remove (4) dl lights and ground connections, install (1) 27kv switch gear with (3) 2000a busses/ (I) 2000a tie bus/(1I) feeder breakers, install (1J 100a manual transfer switch/ (1)4kva transformer with panel, install (3) exit signs and (5) m/13 fixtures, re install (4) d100 lights with ground connections. install 40#4/0 ground, install ip network equipment. Will service be altered? Ej Yes EXJ No Adding more than 50 amps? C3 Yes IJ No Type of Use: Type of work: [XI New CI Addition El Service Change El Remodel El Tenant Improvement 0 Low Voltage [SI Generator E Fire Alarm 0 Telecommunication El Temporary Service Property Served by: El Puget Sound Energy 0 Seattle City Light WAPennit Center Applications,.Handouts \Permit Applications\ PDPs\ Electrical Permit Application Revised I - 1 7-I9.doex RESIDENTIAL NEW RESIDENTIAL SERVICE D New single family dwellings ..... ................ $ I 80,00 (including an attached garage) El Garages, pools, spas and outbuildings $120.00 ea Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES E] Service change or alteration $120.00 (no added/altered circuits) Service change with added/altered circuits $100.00 number of added circuits $10.00 ea 0 Circuits added/altered without service change.....,„$60,00 (up to 5 circuits) El Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea 0 Meter/mast repair $80.00 LJ Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES Temporary service (residential) $60.00 0 Temporary service (generator) $90.00 0 Manufactured/mobile home service $100.00 (excluding garage or outbuilding) D Carnivals $100,00 Number of concessions $1 1.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 5/10/2019 Cory Simpson 206.937.6150 Print Name: Day Telephone: Mailing Address: 901 Powell Ave SW Suite #100 Renton WA 98057 City State Zip WAPeivnit CenterVApp I ications.H andouts \ Pemnt ApplicationsW DRAElectrical Permit Application Revised I -IT, I Rdocx Cash Register Receipt City of Tukwila Receipt Number R17880 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK EL19-0411 Address: 8123 E MARGINAL WAY 8' n: -3324049092 9319: ELECTRICAL $18 399 51 PERMIT FEEMULTI-FA COMM TECHNOLOGY FEE TOTAL FEES P TECHNOLOGY FEE R000.322.10 .00.00 R000.322.900.04.00 0.00 0.00 $18, 99.51 $919 98 • $919.98 ID BY RECEIPT: R17880 $19,319.49 Date Paid: Thursday, June 13, 2019 Paid By: FOY GROUP Pay Method: CHECK 104737 Printed: Wednesday, June 12, 2019 4:52 PM 1 of 1 CRWYSTEMS DESCRIPTIONS Cash Register Receipt City of Tukwila ACCOUNT I Q PermitTRAK E1.19-0411 Address: 8123 E MARGINAL WAY $ Apn: 3324049002 ELECTRICAL PLAN CHECK FEE R000.345.832.00.00 Receipt Number R17627 0.00 4,599.88 $4,599.88 $4,599.88 TOTAL FEES PAID BY RECEIPT: R17627 $4,599.88 Date Paid: Friday, May 10, 2019 Paid By: FOY GROUP Pay Method: CHECK 104702 Printed: Friday, May 10, 2019 9:26 AM 1 of 1 MS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (2'06) 431-367 Permit Inspection Request Line (206) 438-9350 Froject: Type of Inspection: Address: Date Called: Special lnstructi ns: Date Wanted: a.m. p.m. Requester: Phone No: 4 r Q 3 7 Approved per applicable codes. © Corrections required prior to approval. OMMENTS: n s pector: Da e: 0 REINSPECTION FEE REQUIRED. Prior to next inspection". fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0411 PROJECT NAME: BOEING - VAULT 28 SITE ADDRESS: 13985 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # DATE: 05/10/19 Revision # before Permit issued Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention Public Works Structural Planning Division Permit Coordinator • PRELIMINARY REVIEW: DATE: 05/14/19 Not Applicable ri (no approval/review required) Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 06/11/19 Approved Approved with Conditions 111 Corrections Required ri Denied ri (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Ej Fire D Ping EJ PW 0 Staff Initials: 12/18/2013 Department of Labor and Industries PO Box 44460 Olympia, WA 98504-4460 FOY GROUP CORPORATION 901 POWELL AVE SW #10a RENTON WA 98057 FOY GROUP CORPORATION Lic: EC FOYGRGC863LK UBI:601-930-924 Licensed as provided by Law a Electrical Contactor 41) - GENEML ate:612/2014 Date:‘, 6/12/2020 License #: BUS-099,1437 UBI: 601930924 Issued Date: 01/01/2019 Expiration Date: 12/31/2019 Bus Lio-Outside COntractOr City of Tuk4Ja Business License Nature of Business: ELECTRICAL CONTRACTOR Business Name: FOY GROUP CORP Business Address: 901 POWELL AVE SW, STE 100, RENTON, WA 98057 FINANCE DIRECTOR LICENSEE AGREES TO COMPLY WITH ALL THE_ REQUIREMENTS OF CITY ORDINANCES AND STATE LAWS APPLICABLE TO THE BUSINESS ACTIVITY LICENSED HEREUNDER. This license is to be displayed conspicuously at the location of business and is not tansferi'able or asgipable. Please note the following guidelines in the operation ot' your' bmAness: 1. It is necessary to contact the Finance Office at 206-431-3680 in the event your business: . MoVes within the city limits .of Tukwila . Mc ves outside the city limits . Ceases cperat'on . Changes ownership' . Changes use or type of operation . Will be having a special event (such as a tent sale, parking lot sale or any other event) outside its routine, operation. 2. Additlolai licenses are required if your business has live music/entertainment, tow imcks, amusement devices, solicitors/peddlers, or adult entertainment. 3. Any retail sales tax generated in Tukwila needs to be reported to the Washington State Department of Revenue, under sales tax code # 1729. Tukwila business license renewals are mailed to al; licensed businesses in December and payable without penalty until January 31. All) Washington Department of Labor & lnciustries Home Esprifiel Contact Safety & Health Claims & Insurance A-Z.tridux ROI) My L&I Workplace Rights Trades & Licensing FOY GROUP CORPORATION Owner or tradesperson Principals FOY, SHAWN L, PRESIDENT VAN DER VEEN, ERIC, VICE PRESIDENT FOY, SHAWN, AGENT FOY, DONNY, PRESIDENT (End: 06/21/2016) FOY, DONNY, AGENT (End: 06/21/2016) Doing business as FOY GROUP CORPORATION 901 Powell Ave SW #100 RENTON, WA 98057 206-937-6150 KING County VVA UBI No. Business type 601 930 924 Corporation Governing persons DONNY CHARLES FOY SHAWN LA RAE FOY; Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Registered training agent, Check their eligible programs and occupations. License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. FOYGRGC863LK Effective — expiration 06/12/2014— 06/12/2020 Designated administrator FOY, DONNY C License type Master Electrician Bond Contractors Bonding & Insurance Co Bond account no. Active. Meets current requirements. License no. FOr—DC977D0 $4,000.00 Help us mprove SD8393 Received by L&I 06/12/2014 Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Effective date 05/20/2014 Expiration date Until Canceled Workers' comp Public Works Requirements rWorkplace safety and health fff!. Vtpshington Stoto Dept of Labor intiostnes. Use of this site is pubfect to the lowe c.)f the stafff of Vfifishinotoo Help us improve