Loading...
HomeMy WebLinkAboutPermit EL19-0449 - SHASTA BEVERAGES / GLYCOL - ADD SUBPANEL, NEW LIGHTING, CABINET PUMPS AND EQUIPMENTSHASTA BEVERAGES, INC GLYCOL ROOM 1227 ANDOVER PARK E E L19-0449 Parcel No Address: Project Naurp: City of Tukwila a ent of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 3523049072 Permit Number: 1227 ANDOVER PARK E Issue Date: Permit Expires On: SHASTA BEVERAGES, INC - GLYCOL ROOM EL19'O449 7/25/2019 1/21/2020 Owner: Name: NATIONAL BEVERAGE CORP Address: 81005YV10TMST5TE4000, PLANTATION, WA, 33324 Contact Pen: n: Name: DAVID KEHLE Address: 19l6B0NA|RDKSw'SEA/|LE, WA, 98116 Contracqc Name: Address; License No: Lender: Name: Address: OWNER AFFIDAVIT - NICHOLAS HEATON 1 ''' Phone: (206) 433-8997 Phone: Expiration Date: DESCRIPTION Of WORK: INSTALL NEW SUBPANEL FOR EQUIPMENT AND LIGHTS,INSTALL NEW LIGHTING, CABINET PUMPS AND EQUIPMENT Valuation of sirg. family: $0.00 Valuation of mf/umm: $18,008l0 Type of Work: TENANT IMP Fees Collected: $1,249.20 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: lnternational Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: 2017WA State Energy Code: 2017 2017 2015 Date: ~7'2S- f '^��. I hearby certify that I have read and ,:xamined this permit and know the same to be true and correct, All provisions of Iaw and ordinances go'erning this work will be complied with, whether specified herein or not. The granting of this permit does not oresume to give authority to violate or cancel the provisions of any other gateur|oca||axoregu|adnOconstrucdonnrthpperformvnoeofwmrk. am authorized to sign arid obtain this development permit and agree to th? conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issualce, or if the work is suspended or abandonen for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITI9NS*** 2: A copy of the &ectrical work permit shall be posted or otherwise made readily accessible to the EectricaI Inspector at each work site, 3: Approved plans shall be maintaineo at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 NEC, and requirements for electrical insallations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the pnmidunsofthee|ecthca| code or other ordinances of the jurisdiction. Permft; or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additionl work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUJRED Permit Inspection Line: (206) 438- 350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROU'ND/SLAB ' . CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. E - 0447 Project No. Date Application Accepted: Date Application Expires: -15 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: In ee_ Tenant Name: ,01-117646 Vesteth (Jeri tt PROPERTY OWNER Name: Ovitis 15evouco" tit. Address: Ivo 4,cate. Roc es4-- City: Statewb ‘ Zip:Cibibb CONTACT PERSON — person receiving all project communication Name:avio Kake iwitierit Address: 11 up EtAtige Oz., C),,V CitYjM State\»h . Zip, Phone ft . 4.35,,.1944 Fax: Email: elbevik t ctifielikeveh . crovg State: King Co Assessor's Tax No.: 54/ Z,04 '61017_ Suite Number: New Tenant: Floor: 0 .....Yes JNo ELECTRICAL CONTRACTOR INFORMATION ;.. Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No. Valuation of Project (contractor's bid price): Scope of Work (please provide detailed info 1.144109trn4,kIJO $ I 70 OtiC, nation):61bt&14evi i7UEt vJger,r Fttipm. tUpMt4 u23r4, Will service service be altered? D Yes Adding more than 50 amps? ran Yes E No Type of Use: Type of work: 0 New 0 Addition $. Tenant Improvement 0 Low Voltage 0 Generator 0 Temporary Service 0 Service Change 0 Fire Alarm Property Served by: Puget Sound Energy 0 Seattle City Light W:Terinit CenterVmplications-Handouts Permit Applications \ PDFsWlectricel Permit Application Revised 1-17-19. does 0 Remodel 0 Telecommunication Page) of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $180.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $120.00 ea ❑ Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $120.00 (no added/altered circuits) ❑ Service change with added/altered circuits $100.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $60.00 (up to 5 circuits) ❑ Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea ❑ Meter/mast repair $80.00 ❑ Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $6000 ❑ Temporary service (generator) $90.00 ❑ Manufactured/mobile home service $100.00 (excluding garage or outbuilding) ❑ Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: jj�� Print Nam b�IV $etike Mailing Address: i Ora 901+ Date: b*/frSi�WI+t Day Telephone: '�/-1Ilk' City W:IPermit Center\Applications-HandoutsWern it Applications lPDP's\Electrical Permit Application Revised I-17-19.docx ' '@ State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $477.06 E119-0449 Address: 1227 ANDOVER PARK E Apn: 3523049072 $70.00 ELECTRICAL $70.00 ADDITIONAL PLAN REVIEW R000.345.830.00.00 0.00 $70.00 M19-0132 Address: 1227 ANDOVER PARK E Apn: 3523049072 $407.06 MECHANICAL $387.68 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $354.53 TECHNOLOGY FEE $19.38 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18623 R000.322.900.04.00 0.00 $19.38 $477.06 Date Paid: Thursday, September 19, 2019 Paid By: NATIONAL BEVERAGE CORP Pay Method: CHECK 477.06 Printed: Thursday, September 19, 2019 2:54 PM 1 of 1 WY5 TEMS DESCRIPTIONS . _ ACCOUNT QUANTITY PA D PermitTRAK 2,092.33 D19-0171 Address: 1227 ANDOVER PARK E Apn: 3523049072 $736.59 Credit Card Fee $21.45 Credit Card Fee R000.369.908.00.00 0.00 $21.45 DEVELOPMENT $715.14 PLAN CHECK FEE R000.345.830.00.00 0.00 $715.14 E119-0449 Address: 1227 ANDOVER PARK E Apn: 3523049072 $701.09 Credit Card Fee $20.42 Credit Card Fee R000.369.908.00.00 0.00 $20.42 ELECTRICAL $680.67 PLAN CHECK FEE R000.345.832.00.00 0.00 $680.67 M19-0086 Address: 1227 ANDOVER PARK E Apn: 3523049072 $341.93 Credit Card Fee $9.96 Credit Card Fee R000.369.908.00.00 0.00 $9.96 MECHANICAL $331.97 PLAN CHECK FEE R000.322.102.00.00 0.00 $331.97 M19-0087 Address 1227 ANDOVER PARK E Apn: 3523049072 $123.58 Credit Card Fee $3.60 Credit Card Fee R000.369.908.00.00 0.00 $3.60 MECHANICAL $119.98 PLAN CHECK FEE R000.322.102.00.00 0.00 $119.98 M19-0088 Address: 1227 ANDOVER PARK E Apn: 3523049072 $49.78 Credit Card Fee $1.45 Credit Card Fee R000.369.908.00.00 0.00 $1.45 MECHANICAL $48.33 PLAN CHECK FEE R000.322.102.00.00 0.00 $48.33 M19-0089 Address: 1227 ANDOVER PARK E Apn: 3523049072 $105.11 Credit Card Fee $3.06 Credit Card Fee R000.369.908.00.00 0.00 $3.06 MECHANICAL $102.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $102.05 Date Paid: Wednesday, May 29, 2019 Paid By: NICHOLAS HEATON Pay Method: CREDIT CARD 029702 Printed: Wednesday, May 29, 2019 2:29 PM 1 of 2 STEM .5 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 PermitTRAK$2,092.33 ACCOUNT QUANTITY PAID PG19-0075 Address: 1227 ANDOVER PARK E Apn: 3523049072 $34.25 Credit Card Fee $1.00 Credit Card Fee R000.369.908.00.00 0.00 $1,00 PLUMBING $33.25 PLAN CHECK FEE TOTAL FEES, PAID BY RECEIPT: R17750 8000.322.103.00.00 0.00 $33.25 $2,092.33 Date Paid: Wednesday, May 29, 2019 Paid By: NICHOLAS HEATON Pay Method: CREDIT CARD 029702 Printed: Wednesday, May 29, 2019 2:29 PM 2 of 2 SYSTEMS CO TUKWILA ETRAKIT 0288 SOUTHCENTER BLVD TUKWILA, WA 98188 206'433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 05/29/2019 02:27:59 PM CREDIT CARD SALE VISA CARD NUMBER: ******p*+9037 K TRAN AMOUNT: $2,092.33 APPROVAL CD: 029702 RECORD #: 000 CLERK ID: Bill X {CARDHOLDER'S SIGNATURE} Z AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $5,803.30 D19-0171 Address: 1227 ANDOVER PARK E Apn: 3523049072 $2,585.75 DEVELOPMENT $2,475.72 PERMIT FEE R000.322.100.00.00 0.00 $1,100.21 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 STRUCTURAL CONSULTANT R000.345.830.01.00 0.00 $250,30 PERMIT FEE R000.322.100,00,00 0.00 $1,100,21 TECHNOLOGY FEE 5110.03 TECHNOLOGY FEE R000.322.900.04,00 0.00 $110.03 EL19-0449 Address: 1227 ANDOVER PARK E Apn: 352 049072 $548.11 ELECTRICAL $527,03 PERMIT FEE MULTI-FAM/COMM R000,322.101.00.00 0.00 $421,62 PLAN CHECK FEE R000.345.832.00,00 0.00 $105,41 TECHNOLOGY FEE $21.08 TECHNOLOGY FEE R000.322.900.04,00 0.00 $21.08 M19-0086 Address: 1227 ANDOVER PARK E Apn: 3523049072 $1,394.27 MECHANICAL $1,327.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322,100.00,00 0.00 $1,294.73 TECHNOLOGY FEE $66.39 TECHNOLOGY FEE R000.322.900.04.00 0.00 566,39 M19-0087 Address: 1227 ANDOVER PARK E Apn: 3523049072 $503.93 MECHANICAL $479.93 PERMIT ISSUANCE BASE FEE R000.322.100.00,00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $446.78 TECHNOLOGY FEE $24.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $24.00 M19-0088 Address: 1227 ANDOVER PARK E Apn: 3523049072 $203.00 MECHANICAL $193.33 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100,00.00 0.00 $160.18 TECHNOLOGY FEE 59,67 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.67 Date Paid: Thursday, July 25, 2019 Paid By: SHASTA BEVERAGES, INC Pay Method: CHECK 602062 Printed: Thursday, July 25, 2019 10:10 AM 1 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT 1 QUANTITY PAID PermitTRAK $5,803.30 M19-0089 Address: 1227 ANDOVER PARK E Apn: 3523049072 $428.59 MECHANICAL $408.18 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 533.15 PERMIT FEE R000.322.100.00.00 0.00 5375.03 TECHNOLOGY FEE $20.41 TECHNOLOGY FEE R000.322.900.04.00 0.00 $20.41 PG19-0075 Address: 1227 ANDOVER PARK E Apn: 3523049072 ' $139.65 PLUMBING $133.00 PERMIT FEE 8000.322.100.00.00 0,00 598.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 TECHNOLOGY FEE $6.65 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R18190 $6.65 $5,803.30 Date Paid: Thursday, July 25, 2019 Paid By: SHASTA BEVERAGES, INC Pay Method: CHECK 602062 Printed: Thursday, July 25, 2019 10:10 AM 2 of 2 Y TEM5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PRMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit Inspection Request Line (206) 438-9350 Project: A Typeo Inspection: , Address: Date Ca led: Special Instructi7 s: L. Rti iDate Wanted: 1 t am. p.m. Reque e : Phone No: Approved per applicable codes. Corrections required prior to approval. pector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPEC ION NO. INSPECTION RECORD Retain a copy with permit T NO. ITV OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-357 Permit Inspection Request Line (2O6) 438-9350 PrDject� tt _ � j..r- Type of Inspection: Address: Date Called. Special Instruct ons: gate Wanted: p.m. ^' Requester Phone No: 7 7af,Z- Approved per applicable codes. rections required prior to approval. nspecto Date: REINSPECTIN FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. \ Lighting Summary LGT-SUM 2015 Washington State Energy Code Comptance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write- protected. Project Title: _ , ..1 Date A r MIIIIIIIIIIIIII For Buildingpa en Use — - • -----' , ... . — . Applicant Information. Provide contact information for individual who can respond to inquiries about compliance fom, information provided. Company Name: . • Company Address:tn. , Applicant Name: Applicant Phone: , , - .. Applicant Email:, • we Q a 6ell • Ary>t . 014A Project Description 0 New Building 0 Addition PA Alteration Wiens Included Include PROJ-SUM form (included in envelope forms woritbook) with lighting complliance fotms. Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method lnteriortgtfl1ng Exterior lighting Lighting systems in addition area comply with all applicable ; 0 0 provisions as a stand alone new construction project Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance 0 0 Addition Is combined with existing: For interior lighting projects, include new + existing interior ligMing fixture wattage in Proposed Lighting Wattage table in LTG -INT -BW or LTG -INT -SPACE km For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior Lighting Select all Control elements the retrofit combination 50% of the some spaces, fixtures are provide separate compliance conditions. type of retrofit lighting power Refer to requirements. All alteration commissioned 0 No theirormi16ii1gIrErig systems uses changed. and Exterior Alterations Lighting Power and Lighting that apply fa the scope project. If project includes of spaces where less than existing fixtures are replaced and 50% or more of the replaced in others, then lightir ng power forms fo the two mbofit Spaces undergoing the same may be combined into compliance form Section C503.6 for additional lighting controls shall be per C408.3. REVIEWED IT COMPLIANCE WITH NFPA '70 - PJL1C JUN 06 2019 City of Tukwila emagoveheavaiimi and exisling space and configuration are not of a in one Lighting Power i Interior lighting . Parking garage Exterior lighting 50% or more of existing are replaced 0 I 1 0 0 Less than 50% of existing are replaced lig I 0 0 Lamp and/or ballast replacement on existing total wattage not increased 0 I 0 0 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD. LTG -INT -SPACE or LTG -EXT form. Less than 50% replaced- Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to afferation. Include new + existing-to-renerin fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD. LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaites. Lighting Controls ! Interior lighting Parldngsarage ' Exterior lighting New wiring installed to serve added 1 ... — E-IEVi, -:r.") FOR fixtures and/or fixtures relocated to new ; :if , • e. Ej RVi1 6 circuit(s) CODEcaPLIAN -i- aFf '3FiTil,:D i New or moved lighting panel 0 Interior space is reconfigured - luminaires unchanged or relocated only 0JON 0 6 2019 New wiring or circuit - For interior lighting, provide required manual irols per C405.2.3, occupancy sensor contiols per C4052.1, daylight responsive controls per c4052. and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls c4o5Crty of Tulcwila New or moved panel- Provide all applicable lighting controls as • AtticvEmmt envisci 0 time switch controls per 0405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per 0405.2.5 do not apply to reconfigured spaces. Change of Space Use 0 Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). identify interior spaces requiring LPD upgrade to the current Corte in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. ELlq 0449 CITY LA MAY 2 9 2019 PERMIT CENTER Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington State Energy Code F n udi R2, R3, R4 over 3 stories and all R1 Revised August 2018 Project Title; Ti `". r,� Date Calcination Area "1.'9 © O Addition - © Addition stand alone + existing ib Spaces where < 50% of o Spaces where a 50% of 0 luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type i Standard © Additional Efficiency Package Option p C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting WattageNOTh' Location (plan #, room #) Space Type Ceiling fieigllt 2 Gross Interior Area in its Allowed Watts per ftp Watts Allowed (watistR2 x area) Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 8 Total Area Retail Display 1 J LTG -INT -DISPLAY Allowed Watts Allowance from 1'b2,. Proposed Lighting Wattage NOS' Location (plan #, room #) Fixture Description NOTE 4, 5, 6 Number of Fixtures Watts' Fixture NOTE 7 Watts Proposed Mat Cry - ix 107 Gwen Aitot IOn-. 1VItp Proposed Retail Display Lighting from LTG -INT -DISPLAY Tota! Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1,10i (. Interior Lighting Power Allowance Note 1- List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting l rtu►es including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track fighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per 0405.4.1, note exception number end leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For fine voltage tnacWbusway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent curent limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building liohtino systems to demonstrate compliance. Refer to C502.1. Lighting Summary, cont. 2015 Washingtn State Energy Code Compkance Forms for Commercial ial Buildings including R2, R3, R4 over 3 stories and all R1 LGT-SUM Re sed August 2016 Project Title: ► _ r Date . Interior Lighting System Description . 4. ,1y Interior Lighting Power Allowance Method 0 Building Area Method % Space -by -space Method Select method used in project. Interior Lighting Controls yl All C405.2.1- C405.2.8 Controls p 0405.2 Exception 5 Luminaire Level Lighting Control (LLLC) o Additional Efficiency Package Option 0406.4 Enhanced digital lighting controls To comply with 0406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406,4. Dwelling Unit Interior Lighting 14,*fre Permanently installed interior lighting fixtures in dwelling units comply twih: 0 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA 0 C406.3 High Efficacy Lighting 0 Exterior Lighting System Description / Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG -CHK 2015 Washington State Energy Code Compttanee Fomn fo ConinectatBuildings indudtng R2, R3, R4 over 3 stories and an R1 Revised August 2016 ProjectT : . • . Date The Howng information s necessary 10 check a permit application for compIancelighting, motor, and - I requirements in the Washtngton State Energy Code, Commercial Provisions. Aplbihty (yes,no,na) Code Section Component Compliance information required in permit documents LoCabon in Documents tuitdIflg Uepartment Notes LIGHTING CONTROLS . C405 2 Lighting , general For all lighting fixtures, indicate lighting control method on plans lbr spaces and hghtingzone(s) served, or exception taken 41 C405.2 Luminaire level Iighting (LLLC)controls icate on plans all tlxtures provided with LLLC in lieu o 0405.2 lighting controls; provide description of control copabllities and performance parameters uk C405.1 Lighting in dwelling units Fof permanentiy installed lighting fixtures in dwelling units, indicate Fighting control method on plans for spaces and Ughlirig zone(s) served, or demonstrate compliance with high efflcacy exception 0405.2.3 C405.2.1.1 0405.2.2.2 C405.2,4 C405.2.5 Manual controls Indicate on plans the method ofmanual lighting control (wtiether combined whit occupancy sensor, automatic light reduction, QM lei daylight responsive or specific application controls), location of rnanual control device and area or specifice application it serves C405.2.2. 1 0405.2.2.2 0405.2.3 Manual interior h ligting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls tli CC, f ;CPI C405.2.2 Method of automatic shut-off control tndicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; " Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which •time switch control exception applies C405.2.1 0405.2.1.1 Occupancy sensor controls lndicate on plans the . - ces served. occupa sensors; e iipt Indisate controls are confi9ured to , automatic 50% -on, or serve a space eligible for automatic1 exception 0405.2.1.2 Occupancy controls - warehouses •cate aisleNays and open areas in warehouse spaces pravided wthreduce lighting power by 50% 0405.2.6 Digital timer switch ' ired digital timer switch control function when control is used 0405 .221 Automatic time switch controls Indicate locations of override switches on plans and the lighting served, include sq. ft. Hjbr 05.2.4.2 0405.2.4.3 Daylight r - Sidelight topligh a Indisate pnmarysidelight daylight zone areas on plans, include sq. It; Indicate toplight d!yf.! on plans, include sq. It.; --1 For small vertical fenestra • assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to dayliqht zone calculation(s)4 040524 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; lndicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power, Indicate that daylight sensing controls are configured to cornpletety shut off all controlled lights in the lighting zone uJ qp 0405.2.5 Additional controls - Specific application lightirl) controls identify spaces and lighting fixtures on plans that require specific application lighting controls per this section C405.Z 5 - tems 182 Display andaccen lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general lighting and other lighting applications within the same ; lndicate manual and automatic lighting control method Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG -CHK zulo vvasomgcon 1,31.5 mangy t-,ose tAITIpilaTICO FORTIS Tor 1.01TIFIRCITS31 tnaltlinys int -lumina rtc, ma, r... um .) *WI VOT. NA ..... Project T : }4 t2b , 74 , Date. . The owing information is necessary to check a permit application for compliance compiance withighting, motor, and electiical �quireTflefltsin e Washington State Energy Code, Commercial Provisions, Applicability (yes,no,na) Code Section Component Compliance information required in permit documents LoCat2On n Documents Buiiding cepa en Notes VtC405.2.5 - Item 3 Hotel/motel guest s Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in !. uest room C405.2.5 - Item 4 Supplemental task lighting Indicate method andlocation of automatic shut-off vacancy control for task lighting, including under -shelf or supplemental under -cabinet . . ng C405.2.5 - Item 5 Lighting for non- visual applications Indicate plans eligible non -visual lighting applications, rtclude sq. ft. area of each lighting control zone; lndicate on plans that non -visual lighting are controlled ndependenhly from both general area lighting and other lighting apphcationswithin the same space; IndicateI lighting control and applicable autornalicr. ti . controt C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space: Indicate method of manual lighting control and applicable automatic li. hti ,. control C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; e isf,1 Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control v4LA C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served' . For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed ning/dosing time; For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after dosing to 1 hour before opening, or based upon motion sensor C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or, are controlled by motion sensor, or are exempt lighting per C405.5.2 C405.2.5 Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded 80% C406.4 Enhanced digital lighting controls To comply with additional efficiency package option, indicate on plans ail interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package o on C405.13 C408.3 n functional testing I claiminglighting I exemption provide p ' teflon; - a • ble commissioning documentation requirements per Sectionr eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response 4 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director February 5, 2020 David Kehle 1916 Bonair Dr SW Seattle WA 98116 RE: Request for Permit Extension Electrical Permit EL19-0449 Shasta Beverages, Inc. — Glycol Room —1227 Andover Park E Dear Mr. Kehle, This letter is in response to your written request for an extension of permit number EL 19-0449 received in our office on January 15, 2020. It has been determined that the City of Tukwila Building Department does not need to extend the permit at this time as an inspection was requested on January 17, 2020 and performed on January 21, 2020. Based on the inspector's report, this inspection automatically extends the permit 180 days. The new expiration date is July 19, 2020. If you have any concerns or questions, feel free to contact me in the permit center at 206 431-3670. Sincerely, 12)Ac.Le Bill Rambo Permit Technician File: Permit No. EL19-0449 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov david kehle January 15, 2020 0 Request for Pe471i$1Extension # Current Expiration Date: 1—)--1-2-02--0 Extension Request: :407, Approved AJ Afor L_! Denied (provide explanation) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: Mr. Jerry Hight RE: Shasta Beverage Inc, 1227 Andover Park E Tukwila, WA 98118 Tenant Improvement Permit Extension EL19-0449 Glycol Room Permit Extension M19-0010 Glycol Room Permit Extension M19-0086 Can Line 2 Permit Extension PG19-0114 Water Main Rev. Dear Mr. Hight, days Signature/Initials RECEIVED CITY OF TUKWILA JAN 1 5 2020 PERMIT CENTER I am in receipt of letters from Bill Rambo, permit tech, that the above permits will be expiring soon. I am asking for an extension to these permits for the following reasons: 1. There are ongoing owner revisions due to construction inadequacies that need to be resolved and correction comments from Fire will impact the permits. Glycol Room has had a revision resubmittal and has not been re approved. 2. The Can Line 2 and Water Main inspection was dropped by Shasta due to a personnel change recently impacting call for inspections. 3. There are sequences of projects that need to be completed prior to having final inspections occur due to limitations on space in the facility ( ie build this first and then build the next which takes longer to complete). This has impacted the Can Line 2 and Water Main Revision construction and therefore there was nothing to inspect. Can Line 2 can have inspections called for now. 4. There are on going City concerns that are being addressed delaying construction and inspections. This impacts the Glycol Room from Fire. 5. There are some cost implications of the construction which impact cash flow for construction. I believe these are adequate to allow for the extension of the permits. Sincerely, David Kehle 1916 Bonair Drive S.W. Seattle, WA 98116 Ir (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch,com 12/3/2019 City of Tukwila Department of Community Development DAVID KEHLE 1916 BONAIR DR SW SEATTLE, WA 98116 RE: Permit No. EL19-0449 SHASTA BEVERAGES, INC - GLYCOL ROOM 1227 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/21/2020. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/21/2020, your, permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL19-4449 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 FIR david kehle August 5, 2019 BHC Consultants, LLC 1601 Fifth Avenue, Suite 500 Seattle, WA 98101 Attn: Mr. William Hill RE: Shasta Beverage Inc, 1227 Andover Park E Tukwila, WA 98118 Tenant Improvement Glycol Room D19-0171 Glycol Room M19-0089 Venting Glycol Room PG19-0075 floor drains Glycol Room M19-0010 Refrigeration Dear Mr. Hill, REVISION NOL flECEIVEf) CITY OF TUKWILA AUG 08 2019 PERMIT CENTER As the Design Professional In Responsible Charge, I have reviewed the attached revised permit drawings based on your correction letter of April 22, 2019 and owner revisions. I am including new KHS drawings which is the refrigeration piping which was under M19-0010 which was reviewed by Allen Johnannessen previously and response to his comment letter were sent to the city in July. Building Review 019-0171 1. Previous comment letter items were addressed 2. Revised sheets, G000 -G008, A000, A100, P110, P101, E001, E101, E102, M100,M101,M200,M201 are revised by owner dated 6/7/19 rev 3. 3. New drawings from KHS, refrigeration, dated 6/7/19 "construction" sheets 1-14, should be attached to the overall building plans for reference. 4. All other drawings have not been revised. Electrical EL19-0449 1. While this permit has been issued, these changes should be incorporated, owner revisions' Plumbin and Gas PG19-0076 Owner revisions but no change in that water only is being discharge Mechanical Venting M19-0089 1. Owner revision and coordination with KHS refrigeration drawings L ci 9 1916 Bonair Drive S.W. Seattle, WA 98116 (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch.com Fire Department Comments for M19-0089 and D19-0117 1. Mr Metzler had requested a stamped letter regarding IFC Section 606.12.1 and IIAR-1 and IIAR-7. This comment was written prior to the KHS drawings being revised and submitted under M19-0010. The KHS drawings have several sections that respond to pressure relief systems for the installation as are noted on Pages 2, Pages 11 and 12. Safety systems are noted on Page 14. Page 5 shows the emergency manual shutoff. I am writing a separate cover response to Mr. Metzler noting these items on the KHS drawings. I trust this will answer his concerns. I believe that this will expedite the Glycol Room permit and I look forward to your approval and the permit issuance from the City. If you have any other comments regarding these permits, please let me know. Sincerely, arl David Kehle Encl: 2 copies Revised sheets Glycol Bldg, 2 copies revised sheets for P,E,and M and KHS drawings Cc: Mr Jerry Hight david kehle architect June 12, 2019 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: Mr. Bill Rambp RE: Shasta Beverage Inc, 1227 Andover Park E Tukwila, WA 98118 Tenant Improvement Electrical Glycol Room EL19-0449 Dear Bill, As we discussed earlier, the valuation of project was miss read and was to be $18,000.00. Please amend the application and re compute the fees owing. David Kehle 1916 Bonair Drive S.W. Seattle, WA 98116 RECEIVED CITY OF TUKWILA AUG 0 5 2019 PERMIT CENTER (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch.com TO: FROM: DATE: SUBJECT: Sherry Wright Rachelle Ripley June 7, 2019 Refund for Electrical Permit EL19-0449 MEMORANDUM Please draw a check in the amount of $701.09 (seven hundred -one dollars and nine cents) to be payable to Shasta Beverages Inc. c/o Nicholas Heaton, at 1227 Andover Park E, Tukwila WA 98188. The fees were paid with a personal credit card and the payee (Nicholas Heaton) has already been reimbursed by Shasta Beverages Inc. The fees were calculated incorrectly. Please provide the refund as follows: Account ; - ,,, ,Amount 000.345.832.00.00 $680.67 000.369.908.00.00 $20.42 Total $701.09 Thank you! May 28,2019 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: Mr. Jerry Hight RE: Shasta Beverage Inc, 1227 Andover Park E Tukwila, WA 98118 Tenant Improvement Glycol Room Dear Mr. Hight, As the Design Professional In Responsible Charge, I have reviewed the attached permit submittal, drawings and calculations for the single story Glycol and Ammonia Storage room, prepared by Plump Group including structural engineering. This is a semi heated space and so no change to the building envelope. Also included for permits are Electrical, Plumbing, and Venting for this room and equipment (tanks) inside. I believe these are adequate for permit submission and initial review. Please accept for permit review. David Kehle ELVt 1916 Bonair Drive S.W. Seattle, WA 98116 RECEIVED CITY OF TUKWILA MAY 2 9 2019 PERMIT CENTER (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch.com t, PERMIT WORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0449 DATE: 08/08/19 PROJECT NAME: SHASTA BEVERAGES, INC - GLYCOL ROOM SITE ADDRESS: 1227 ANDOVER PARK E Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: 11"iO Wit u dinguvistoA Public Works Fire Prevention Structural Planning Division Permit Coordinator gp PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 08/13/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 09/10/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 1:1 Fire D Ping LJ PW Staff Initials: 12/18/20D PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0449 DATE: 05/29/19 PROJECT NAME: SHASTA BEVERAGES, INC - GLYCOL ROOM SITE ADDRESS: 1227 ANDOVER PARK E X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works n Fire Prevention Structural Planning Division Permit Coordinator Li 1 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/30/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 06/27/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping PW D Staff Initials: 12/1812013 PROJECT NAME: SITE ADDRESS: PERMIT NO: El -4H 0L114 ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS r Summary of Revision: Up ofrvi-14,YZAW iltS Received by: Received by: 0), REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Steven M. Mu1kt, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: littp:#www,ci.tukwila.wa.us SVve Lancaster, Director REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, far, etc. Date: (*oratiel Plan Check/Permit Number: D Response to Incomplete Letter # LJ Response to Correction Letter # LJ Revision # 1 after Permitistssnuct 151 LJ Revision requested by a City Building Inspector or Plans Examiner Project Name:*trisig ii3e4X4446 Project Address: V2 -1.1 -e• Contact Person:VANPO Ve.O.Le Phone Number: lap Summa721Revlsion: 1.47-1ee 16 1366 61-111 IIECEIVEL CITY OF TUKWILA AUG 08 2019 Sheet Number(s): ecet , g ict "Cloud" or highlight all areas of revision including date o Received at the City of Tukwila Permit Center by: Entered in Permits Plus on ?)--- NTER kapplications‘forrns-appLicauons on linerevisian submittal Created: 8-13-2004 Revised: CITY OF LA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: tukplan(ci.tukwila.wa.us Permit Center/Building Division 206 431-367o Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACT OR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING di4g9tAS �4/ (,. 7)-r [please print name] , states as follows: PERMIT NO: L 1 J CF 0 I TV)19- o n F 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a peg mit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number I ( , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. GE K vom%%%1 t 4, 00. C P144.5 rA✓,a i4e_ ,-rot Owner/Owner's Agent* Signed and sworn to before me this � 2S ay of SL&+ ,20 1 j N t ' Y PUBLIC in and for the ate of Washington Residing at s sf3 S 3Vs,` / / , CG oounty 9/�"" Name as commissioned: 6t.v1(Slttr'? K Aic hd /$ My commission expires: 1 18.27.090 Exemptions. The registration provisions of this 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who -only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed 1 1 chapter do not apply to: by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in-kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. 5 0 a 2 DEMOLITION NOTES GENERAL NOTES ELECTRICAL SYMBOLS LIST I. DEMOLITION WORK SHALL BE PERFORMED ACCORDING TO THE ARCHITECTURAL PLANS. 2. ALL MATERIALS, LIGHTING FIXTURES, CONVENIENCE OUTLETS, WIRES, CONDUITS, JUNCTION BOXES AND ALL OTHER DEVICES SHALL CONFORM TO MATCH THE EXISTING CONDITIONS AND EQUIPMENT ON THE JOB SITE, UNLESS OTHERWISE NOTED. 3. REMOVE, REROUTE AND REWIRE EXISTING FIXTURES, RECEPTACLES AND JUNCTION BOXES AND PROVIDE NEW BRANCH CIRCUITS, PANEL FEEDERS, AND DEVICES AS SHOWN ON THE PLANS OR AS REQUIRED FOR A COMPLETE OPERABLE SYSTEM, IN FULL ACCORDANCE AND COMPLIANCE WITH ALL APPLICABLE CODES. 4. ALL EQUIPMENT WHICH IS DISCONNECTED AND REMOVED SHALL BE RETURNED TO THE OWNER. 5. FURNISH AND INSTALL ALL NECESSARY CONDUITS, WIRES, JUNCTION BOXES. BLANK COVER PLATES, ETC. AT ALL LOCATIONS AFFECTED BY RELOCATION OF OUTLETS. 6. WHERE INTERRUPTION OF A CIRCUITS FEEDING EXISTING EQUIPMENT OCCURS DUE TO NEW WORK, THIS CIRCUIT SHALL BE REHABILITATED AND MADE CONTINUOUS FROM PANEL TO LAST EXISTING OUTLET. 7. THE CONTRACTOR SHALL REUSE EXISTING CONDUIT RUNS AND HOMERUNS WHERE POSSIBLE ACCORDING TO CODES HAVING JURISDICTION, PULL NEW WIRES AS REQUIRED. ALL OTHER EXISTING UNUSED CONDUITS AND WIRES SHALL BE REMOVED BACK TO LAST EXISTING OUTLET. 8. UPDATE PANEL DIRECTORIES AT EXISTING PANELS TO REFLECT NEW WORK. 9. THE CONTRACTOR SHALL VERIFY THE CURRENT IN EXISTING FEEDERS AND BRANCH CIRCUITS THAT ARE AFFECTED BY THIS PROJECT PRIOR TO ADDING LOAD TO EXISTING CONDUCTORS, BREAKERS, PANELS, TRANSFORMERS OR SWITCHGEAR. NOTIFY ARCHITECT IMMEDIATELY IF ANY EXISTING EQUIPMENT IS FOUND TO BE OVERLOADED OR WILL BECOME SO IF NEW LOAD IS ADDED. 10. THIS DRAWING IS BASED ON EXISTING DRAWINGS AND OWNER SUPPLIED INFORMATION. THERE HAS BEEN NO VERIFICATION OF PRECISE LOCATIONS, WIRING OR OPERATION OF EXISTING EQUIPMENT. CONTRACTOR SHALL VERIFY ALL JOB CONDITIONS PRIOR TO BID. CONTRACTOR SHALL THOROUGHLY EXAMINE AND VERIFY POINTS OF CONNECTION, ACCESSIBILITY, SIZES, LOCATIONS, ELEVATIONS, ETC. EXISTING CONDITIONS FOUND UNACCEPTABLE OR IN VIOLATION OF CODES AND AUTHORITIES HAVING JURISDICTION SHALL BE CORRECTED. 11. CONTRACTOR SHALL PERFORM ALL VERIFICATION, OBSERVATION,TEST, AND EXAMINATION WORK PRIOR TO THE ACTUAL CONSTRUCTION. HE SHALL ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE ARCHITECT LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. 12. ADDITIONAL LABOR AND MATERIAL REQUIRED TO PROVIDE A COMPLETE AND OPERABLE SYSTEM IN ACCORDANCE WITH CODES AND ALL AUTHORITIES HAVING JURISDICTION NOT LISTED IN THE WRITEN NOTICE TO THE ARCHITECT SHALL BECOME PART OF THE CONTRACTOR'S WORK JUST AS IF IT WERE INDICATED AND IMPLIED ON THE PLANS. ABBREVIATION AFF AFG AIC BC BKBD CO E,(E) ECP EG EM ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMP INTERRUPTING CURRENT BARE COPPER BACKBOARD CONDUIT ONLY EXISTING ENVIRONMENTAL CONTROL PANEL EQUIPMENT GROUND EMERGENCY FLA FSP GFCI G, GND, GRD IG LCL N,(N) NF NL FULL LOAD AMPS FIRE SUPPRESSION PANEL GROUND FAULT CIRCUIT INTERRUPTER GROUND ISOLATED GROUND LONG CONTINUOUS LOAD NEW NON -FUSED NIGHT LIGHT R,(R) SCC SAD SMD UNO VL WP WT REMOVE, RELOCATE SHORT-CIRCUIT CURRENT SEE ARCHITECTURAL DRAWING SEE MECHANICAL DRAWING UNLESS NOTED OTHERWISE VERIFY LOCATION WEATHERPROOF WATER TIGHT EKG LLH LED LINEAR HIGHE3AY DESCRIPTION A cost-effective solid state LED solution for highbay and lowbay applications, repladng up to 250watt and 400 watt HID fixtures and multi -lamp fluorescent luminaires. FEATURES • >130 Ipw ultra -high efficiency delivers superior performance over fluorescent and HID, saving up to 60% of energy costs • Universal 0-10V driver for continuous dimming • 15 items feature pre -installed adjustable microwave occupancy sensor LISTINGS • UL Listed for damp locations • DesignLights Consortium+Premium Qualified • meets the requirements for the highest DLC qualification for efficacy and lumen maintenance PERFORMANCE • Rated lifetime L70 >100,000 @ 40°C (104°F) >72,000 @ s0°C (122°F) • 4000K, 5000K CCT • CRI; 801- ELECTRICAL Input voltage: 120.27TV, 347-480V Dimmable power supply (0-10V) Driver efficiency: >8596 Power Factor >.9 THD: <20% SEPARATE PERMIT REQUIRED FOR: (i,2f Mechanical E. Electrical [� Plumbing 12/ Gas Piping City of Tukwila BUILDING DIVISION THERMAL • -22°Fto 122°F(•30°C to 50°C) operating temperature CONSTRUCTION • Heavy gauge steel body with welded frame construction resists twisting and bowing • Diffuse frosted acrylic lens to control glare (standard) or optional clear lens for higher light output (sold separately) • 10 ft. Y-toggle aircraft cable mounting hardware included • Built-in 2.5kV surge protection WARRANTY • 5 year limited warranty; see elko.com for warranty details ORDERING INFORMATION LLH : LED Linear Hlghbay 1 '1C-110W;14,0001m 2C -162W: 21.0001m 3C - 223W: 29.000 Im _ )r.SW 'iS IYN1 Im ,numb.. jSC-321W,42,0001m I 40K- 4000K I SOK- 5000K project name caUNgnuniber . comments __.._.._ _..... approved by APPLICATIONS • Warehouses • Manufacturing Plants • Distribution Centers • Grocery Stores • Gymnasiums 9pe voltage date.. t.; 2c L..,. 3C •R. L .0 L 'c • Indoo' Recreational Facilites • Cold Sorage • Big Bc• Retail • Service Repair Centers CoHSfR nt OOUS ROHS 1 ' IU - 120-277V V-.i41-480v I E+KCUSA:1800 85.22217 I FAO T anada: l: EXAMP.2: LLH-IC-SOK-U-15 1S • 0:cupancy Sensor (Wank) - No sensor 11 I, 1 eikp.corn 61 • 3 raw air i i3n feiPew. 1. ELECTRICAL CONTRACTOR SHALL VERIFY VOLTAGE, HORSEPOWER RATINGS, EXACT LOCATIONS OF ALL ELECTRICAL AND OTHER EQUIPMENT PRIOR TO ANY ROUGH -IN. IF DISCREPANCIES ARE NOTED, ADVISE THE ARCHITECT/ENGINEER IMMEDIATELY. 2. SEE RELATED WORK SHOWN ON CONSTRUCTION DOCUMENTS PREPARED BY THE ARCHITECT FOR WORK AND MATERIALS TO BE FURNISHED AND INSTALLED UNDER THIS WORK. 3. LOCATE LIGHT FIXTURES 50 AS TO AVOID ALL EQUIPMENT FURNISHED BY OTHER TRADES. COORDINATE ALL ASPECTS OF INSTALLATION PRIOR TO ROUGH -IN. 4. THE ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2014 EDITION OF THE NATIONAL ELECTRICAL CODE. AND ALL. LOCAL CODES HAVING JURISDICTION. 5. ALL LIGHT FIXTURES SHALL BE FURNISHED TO MATCH WITH THE CEILING TYPE IN WHICH THEY ARE INSTALLED. PRIOR TO BID, CONTRACTOR SHALL VERIFY CEILING TYPE INDICATED ON ARCHITECTURAL DRAWINGS. LOCATE ALL LIGHT FIXTURES AS SHOWN ON THE REFLECTED CEILING PLAN. 6. ALL ELECTRICAL EQUIPMENT EXPOSED TO THE WEATHER OR DAMP AND WET AREAS SHALL BE WEATHERPROOF AND HAVE UL LABEL CONSISTENT WITH APPLICATION (NEMA 3R). 7. CONTRACTOR SHALL FURNISH AND INSTALL AN AUXIUARY JUNCTION BOX AT ALL LOCATIONS WHERE A RECESSED LIGHT FIXTURE IS SHOWN WITH MORE THAN EIGHT (8) WIRES CONNECTING OR RUNNING THROUGH IT. SEE NEC 370-6 AND 410-11. 8. CONTRACTOR SHALL OBTAIN THE EQUIPMENT SUPPLIER'S DRAWINGS AND INFORMATION RELATIVE TO THIS PROJECT. HE SHALL UTILIZE THIS INFORMATION FOR EXACT POINTS OF CONNECTION. NO INSTALLATION SHALL BE PERMITTED IN VIOLATION OF MANUFACTURER'S RECOMMENDATIONS. 9. ALL ELECTRICAL EQUIPMENT SHALL BE NEW AND U.L. LISTED. 10. UGHTING FIXTURE CATALOG NUMBERS, VOLTAGES, AND LAMP TYPES ON THE FIXTURES SCHEDULE SHALL BE TREATED AS MINIMUM REQUIREMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION OF ALL VOLTAGES, NUMBERS, LAMP TYPES AND MOUNTINGS. 11. CONTRACTOR SHALL FURNISH AND INSTALL A GROUND WIRE IN ALL CONDUITS. GROUND WIRES MAY NOT BE SHOWN, BUT SHALL BE INCLUDED IN THE ELECTRICAL CONTRACTOR'S BASE BID AND SIZED PER NEC ARTICLE 250-94 AND 250-96, OR AS NOTED ON DRAWINGS. 12. FACILITIES SYSTEMS: AT NO TIME SHALL ANY WORK BE DONE THAT MAY INTERRUPT THE OPERATIONS OF ANY EXISTING FACILITIES WHICH AFFECTS PEOPLE OR EQUIPMENT OUTSIDE THIS SCOPE. IF, IN THE OWNER'S OPINION THERE IS NO POSSIBLE WAY TO AVOID SUCH DISRUPTION, THE CONTRACTOR SHALL CONTACT APPROPRIATE AUTHORITIES. SUBMIT A PLAN FOR APPROVAL TO THOSE RESPONSIBLE. OBTAIN ALL AGREEMENTS. AND THEN COMPLY WITH THOSE AGREED UPON PROCEDURES IN ALL ASPECTS, COORDINATION OF OUTAGE OF ANY SYSTEM SHALL BE EXECUTED WITH SUFFICIENT ADVANCE NOTICE SO AS TO MINIMIZE THE IMPACT OF THE INTERRUPTION OF SERVICES. 13. CONTRACTOR TO TAG/IDENTIFY ALL CONDUCTORS FOR EQUIPMENT INSTALLATION. 14. CONDUIT AND DUCT RUNS ARE SHOWN SCHEMATICALLY. BUILDING CONDITIONS WILL DETERMINE THE ACTUAL RUNS. 15. THE CONTRACTOR MUST VISIT THE SITE PRIOR TO SUBMITTING A BID AND INCLUDE ALL REQUIREMENTS FOR EXISTING FIELD CONDITIONS IN HIS PRICE. 16. ALL SWITCHES AND RECEPTACLES SHALL BE SPECIFICATION GRADE AND 20 AMPERE MINIMUM. WALL - PLATES SHALL BE TYPE 302 STAINLESS STEEL, COLOR OF DEVICES TO BE SELECTED BY ARCHITECT. 17. ALL WIRING SHALL BE INSTALLED IN RACEWAYS. 18. ALL WIRING SHALL BE COPPER, #12 AWG MINIMUM, TYPE THWN AND RATED FOR 600 VOLTS. 19. RACEWAYS ALLOWED: RIGID METAL CONDUIT (REQUIRED IN MECHANICAL ELECTRICAL AND EQUIPMENT ROOMS), EMT, STEEL FLEXIBLE CONDUIT (MAXIMUM LENGTH SHALL BE 6 FEET) AND PVC COATED METAL CONDUIT (REQUIRED UNDERGROUND AND IN EXISTING SLABS). MINIMUM SIZE HOMERUN SHALL BE 3/4", OTHERWISE 1/2" MINIMUM ALLOWED. ANY RACEWAYS WITH 6 OR MORE CONDUCTORS SHALL BE 3/4" MINIMUM (INCLUDING GROUNDING CONDUCTOR). ALUMINUM FLEXIBLE CONDUIT SHALL NOT BE USED. FLEXIBLE CONDUITS EXCEEDING 6 FEET IN LENGTH SHALL INCLUDE AN GREEN INSULATED CODE -SIZED EQUIPMENT GROUNDING WIRE, PROPERLY BONDED AT EACH END TO MAINTAIN GROUNDING CONTINUITY AS REQUIRED BY CODE. 20. FITTINGS: GALVANIZED STEEL TYPE; SET -SCREW TYPE. 21. SLEEVES: PROVIDE SLEEVES FOR ALL RACEWAYS AND/OR WIRING THROUGH FIRE -RATED WALLS, CEILINGS AND CONCRETE OR STEEL FLOORS. SEAL SLEEVES, AFTER INSTALLING RACEWAYS, WITH APPROVED FIRE -RATING MATERIAL OF EQUAL RATING AS ORIGINAL FIRE -RATING. CABLES AND WIRING THROUGH SLEEVES SHALL BE SEALED ON BOTH ENTRIES. 22. ALL EXISTING AND NEW PANELBOARDS SHALL HAVE TYPE -WRITTEN DIRECTORIES ADDED BY THE CONTRACTOR INDICATING EXISTING CONDITIONS, PRESENT MODIFICATIONS AND NEW WORK. 23. SEAL ALL PENETRATIONS THOUGH FLOOR OR FIRE RATED WALLS WITH FIREPROOFING MATERIAL THAT HAS AN EQUIVALENT FIRE RATING AS THAT OF THE EXISTING CONDITION. 24. THE ELECTRICAL WORK SHALL BE GUARANTEED FOR A PERIOD OF NO LESS THAN ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER. ANY WORK, MATERIAL, OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE UPON WRITTEN NOTIFICATION AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. 25. ALL CONDUIT ONLY (C.O.) SHALL HAVE A PULL WIRE OR ROPE. 26. PROVIDE THE OWNER WITH ONE SET OF COMPLETE ELECTRICAL REPRODUCIBLE DRAWINGS AT THE COMPLETION OF THE JOB SHOWING ACTUAL DIMENSION AND CIRCUITS. 27. ALL BROCHURES, OPERATING MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE TURNED OVER TO THE OWNER AT JOB COMPLETION. 28. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDITION. 29. PATCH, REPAIR, AND PAINT TO MATCH SURROUNDING CONDITION, ANY AREA DAMAGED IN THE COURSE OF THE ELECTRICAL WORK. LIGHTING FIXTURE SCHEDULE CLG. WALL FLR. DESCRIPTION FUSED SWITCH, SIZE AS SHOWN - V.L. NON -FUSED SWITCH, SIZE AS SHOWN - V.L. TIME CLOCK - 7 DAY, SKIP -A -DAY FEATURE WITH MANUAL BY-PASS SWITCH MOTOR OUTLET - IDENTIFICATION SURFACE MOUNTED PANEL 120/208V, 3-PHASE. 4-WIRE 41 MAIN SWITCHBOARD OR POWER DISTRIBUTION BOARD FLEXIBLE CONNECTION %a'CPPROVIDE CORD AND PLUG CONDUIT CONCEALED ABOVE CEILING OR IN WALLS CONDUIT UNDER SLAB OR BELOW GRADE, 3/4" MINIMUM HASH MARKS INDICATE QUANTITY OF #12 WIRES IN CONDUIT, EXCEPT NO HASH CONDUIT RUN EXPOSED MARKS DESIGNATE 2 #12 WIRES. OTHER CONDUIT AND WIRE AS INDICATED HOMERUN TO PANEL "A", CIRCUITS # 1 AND #3 - T- TELEPHONE 3/4" C.O. - U.O.N. TI = 1-1 /4" C.O.; T2 = 1-1/7C.O. INDICATES PLAN NOTE NUMBER "1", SEE PLAN CONDUIT STUB OUT, 3/4" MINIMUM -SEE PLANS FOR NOTES 0 HO LIGHTING FIXTURE OUTLET - VERIFY MOUNTING WITH FIXTURE SCHEDULE ►e► EXIT LIGHT FIXTURE - ARROWS AS SHOWN (90 MINUTES MINIMUM) lagt 0 DUPLEX RECEPTACLE AT+18" / It DUPLEX MOUNTED ABV. COUNTER fac DOUBLE DUPLEX/ DUPLEX RECEPTACLE AT+18"= CONTROLLED NL NIGHT LIGHT 0 CEILING -MOUNTED PHOTOCELL SENSOR Fo JUNCTION BOX AT+18" WALL MOUNTED U.O.N 11-Ig GROUND FAULT INTERRUPTING RECEPTACLE/I.= GEC MOUNTED ABOVE COUNTER / WP DUPLEX/DOUBLE DUPLEX RECEPTACLE, FLUSH FLOOR MOUNTED CL DUPLEX RECEPTACLE, CEILING MOUNTED DEDICATED RECEPTACLE, 208V, 10 SINGLE POLE SWITCH AT 4B" U.O.N. - V.L. 12 3 DOUBLE POLE SWITCH AT +48" U.O.N. - V.L. THREE-WAY SWITCH AT+48" U.O.N. - V.L. $4 FOUR-WAY SWITCH AT +48" U.O.N. - V.L. SYMBOL FIXTURE TYPE WATTAGE VOLTAGE LAMPS DESCRIPTION MANUFACTURER CAT. NO. FINISH MOUNTING REMARK so "a" INDICATES OUTLET CONTROLLED AT+48" U.O.N. (PROVIDE SEPARAT SWITCH FOR EACH DESIGNATION) iM MOTOR CONTROL TOGGLE SWITCH H.P. RATED E 321 120 INTEGRAL 40K LED 1'x4' LED LINEAR HIGHBAY LIGHT FIXTURE EIKO LLH-5C-50K-U-1S WHITE SURFACE LED DRIVER 0-10V DIMMING TO 10% CELING-MOUNTED MOTION/OCCUPANCY SENSOR EE 321 120 SAME AS TYPE "E' EXCEPT WITH EMERGENCY LED DRIVER, AND WITH MIN. OF 90 MINUTES BATTERY BACK-UP. SPECIFICATIONS; INFORMATION ADJACENT TO CALL -OUT INDICATES HORSE DENOTES MECHANICAL EQUIPMENT SEE MECHANICAL DRAWINGS FOR EXACT POWER (H.P.) AND VOLTAGE RATING XE 2.3 120 LED EXIT SIGN WITH 90 MINUTES BATTERY BACK-UP. LITHONIA LQMSW3R I20ELN WHITE UNIVERSAL (E) PANEL 'AR' VOLTS:120/208V PHASE: 3 A.I C. RATING: 22,000 AMP MAIN: 60A MOUNTING: SURFACE WIRE: 4 BUSSING: 125 AMP LOAD • A -VA B-VA C-VA BKR CT CT BKR A -VA B-VA C-VA • LOAD EXHAUST HIGH VELOCITY& LOUVER M 1200 20/3 1 2 60/3 1080 - N 60A WINN -- M 1200 - 3 4 -- 360 - N --- ---- M - 1200 - 5 6 -- 1800 N R L --- ROLL UP DOOR M 1200 20/1 7 8 20/1 360 - ROOFGCFI RECEPTACLES LOW VELOCITY FAN M 800 20/1 9 10 20/1 1284 LIGHTING EM EXITS M 200 20/1 11 12 20/1 1284 L LIGHTING PHASE TOTALS: 3840 3644 4484 11968 =TOTAL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 32.0 30.3 37.3 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS: 1.25 X 2568 = 3210 VA C=CONTINLOUS LOADS, OTHER: 1.25 X 0 = 0 VA M=MOTOR LOADS (INCL LOST): 1.00 X 5800 = 5800 VA LARGEST, VA: 0.25 X 12000 = 3000 VA R=RECEPTACLES: 1ST 10K: 1.00 X 360 = 360 VA BALANCE: 0.50 X 0 = 0 VA K=KITCHEN LOADS: QTY: 0 0.65 X 0 = 0 VA N=NONCONTINUOUS LOADS, OTHER: 1.00 X 3240 = 3240 VA NOTES: (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 15610 VA = 43.3 AMPERES TO EXISTING MAIN SWITCHBOARD PROVIDE MATCHING BREAKER IN EXISTING SPARE OR SPACE (E) PANEL 'AR' 60A 1 2CKT 1 "C. 4# I THHN CU + 1 #8 GND QPORC MOUNT JUNCTION BOX WITH BLANK COVER PLATE 6" ABOVE ACCESSIBLE CEILING FOR MODULAR FURNITURE POWER POLE BY OWNER. "P" INDICATES POWER SUPPLY, "C" INDICATES DATA AND TELEPHONE SUPPLY 4/0 PULL BOX 1 iaD DIMMER/ OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCHING AT +48" 1120 VOLT) OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCHING AT +48" (120 VOLT) fob OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH BI-LEVEL SWITCHING AT+48" (120 VOLT) iabD DIMMER/OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH BI-LEVEL SWITCHING AT+48" (120 VOLT) 7 DATA/TELEPHONE OUTLET, WALL -MOUNTED I DATA OUTLET, WALL -MOUNTED SHEET LEGEND E001 E101 GENERA_ NOTES, SYMBOLS LIST, LIGHT FIXTURE/PANEL SCHEDULES & SLD UGHTING & ROOF POWER PLAN SINGLE LINE DIAGRAM NOTES S1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDUITS ALL NEV 'j 1 po Y g S2. CONDUCTOR SHALL BE COPPER. v 54d¢ S3. ALL EQUIPMENT AND CONDUITS SHOWN ARE EXISTING UNLESS NOTED OTHERWISE. S4. VISIT SITE BEFORE BIDDING PROJECT TO SEE ALL EXISTING CONDUITS. QUALIFY ANY EXISTING CONDITIONS IN BID THAT WERE FOUND DURING SITE VISIT. IF NO SITE VISIT IS DONE IT WILL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO DO PROJECT COMPLETE PER PLANS WITH NO EXTRA COST N NO. 1 RECEIVED CITY OF 1'L t(W ILA AUG 08 2019 P EMIT CENTER EL19- oq-'/ PLUMP ENGINEERING INC CONSULTING ENGINEERS STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, CNIL, SURVEYING, ARCHITECTURAL 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835, F (714) 385-1834 www.peica.com Slamp: �PRDA.p4 Qr ryF WASy r- O -Po Gy , 34218 e cr FR/ S T tS' \�4' s/DNA L EIS t■P. 03/te/20 6/18/19 0 O a. 227 Andover Park E co c000 0 Y F- REVISIONS FOR FOR CITY SUBMITTAL 04/04/19 A PLAN CHECK 4/2212019 CLIENT REVISIONS 2 05/22/2019 CLIENT REVISIONS 06/07/2019 REVIEWED FOE('' COMPLIANCE 1MTH' NFPA 70-Alec AUG 27 2019 JCNy of Tukwila OUILDINC DIVICIDN Project Manager: CR Date 6/18/19 Scale: Project Number: 1903079 'H- V J 1- V) J N J 0 00 fn W 0 J W ,L LJJ V ai m oo c rc cc 0 0 = 0 cc 0 0 a tu a: au a 0. 0 0 a cc • 0 _ 0 CI J V) LLJ J � 6 0 W LL U C) _J LJJ fL LU ` LL SHEET NUMBER EOO1 » a i 8 u 9 7 0 0 0 UZo 8V0 PO 1a, C use. GENERAL NOTES: a PLUMP ENGINEERING c CONSULTING ENGINEERS G1. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS BOXES, MISC. FITTINGS, ECT, FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION AND C.E.C. (2016). G2. ALL PENETRATIONS THROUGH FIRE WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. 1 /:•`/; %/: /: i i/%%%//.�%%/_ \` . _� I -- - --- ------- -------._-. .. / --- ---"' - •---'I / "'"�- -- STRUCTURAL, MECHANICAL, PLUMBING, G3. WHERE A SHARED NEUTRAL CONDUCTOR IS USED FOR MULTIPLE BRANCH CIRCUITS, 1 � -'- / .-_ __.-_ .._ _._.—._.___—_—..__ __. _,_.__„— ,__.. _"...._ _ ? -__-..__.. -. _._-_ _______ ......_ _ _ _ . .___— _ ___ _ ..__.____ _._.___ .. ___-._ _ ___.__..._ _...—... .._.. _.—_ ELECTRICAL CIVIL, SURVEYING, ARCHITECTURAL CONTRACTOR SHALL GROUP CIRCUITS TOGETHER IN PANEL AND PROVIDE A MANUFACTURER FURNISHED HANDLE -TIE TO SIMULTANEOUSLY TRIP ALL OF THE CIRCUITS SHARING THE NEUTRAL 1 j � � ! 1 _ I , jk.. CON / / • TO CONNECT ' I TO CONHIECTTO - ` T ^�. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835, F (714) 385-1834 www.peica.com G4. VOLTAGE DROP IN ACCORDANCE WITH ENERGY CONSERVATION CODE 505.7.3. ALL 120V CIRCUIT LENGHTS GREATER THAN 100 FT SHALL BE INCREASED TO # 10 1 - ---' 1 ! ,;� _ { (E) DB l I,: ( (E) CAB-1 (E) DB l illiG5. I (E) PANEL 'AR'-, I __ _ .-_-__ 2 ` -_ - CONNECT TO \ / 1 (E) DB-1 1 I / I• 5Wit, AWG AND TO #8 AWG WHEN GREATER THAN 160 FT, INCREASE CONDUIT SIZE FOR /Iii� / / i , 11///A _ _ 6 Q// ////��� 1 __ _ _ _ i.T.T'��/• /� 7 111/21 ' /7. 40%FILL. ,,.. I' f_,, F I I„•. AR-1,3.5 1 _... __ . ( "" " I CSCP F l I rAS;250AF,3P t L SOOAS 5�OAP,3P SOOAS SOOAF 3P J(2)21/2"C,3#250,F a e ROLL UP DOOR 1 / KEY NOTES: (2)21/2`C,3#250, C'UG 1. - 3P #2CUG 3p Elect cal Switch Gear \Sere ! I '.fe 1 HOMERUN TO PANELBOARD CIRCUITS & RECEPTACLES SHOWN ARE TO BE 1 , 1 _. 1#2CUGND 1#2CUGND 3"C,3#500,1# WP �m e,GND DB-11600A I , I 1 1 1 � TIED/CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS - - 0 DESIGNATED. (TYPICAL FOR ALL HOMERUN CIRCUITS) - -- I 1 L,_.____ - _ < - - O '�% m EXHAUST FAN 41 o � 2 3 ELECTRICAL CONTRACTOR TO PROVIDE SERVICE DISCONNECTS. PROVIDE WEATHERPROOF GFCI ROOF MOUNTED SERVICE RECEPTACLES LOWER EXHAUST FAN AR-9 i, I o ti w H %', r/ LOCATED WITHIN 25 FEET OF ANY MECHANICAL EQUIPMENT. ill Z Y _ III GFCI 1 z 4 rr// 4 SEALING: WHERE PORTIONS OF INTERIOR RACEWAY SYSTEM ARE ,ii' I a 1 " 1 WP 2 EXPOSED TO WIDELY DIFFERENT TEMPERATURES, CIRCULATION OF AIR FROM • O - �I GFC - f7tr • '----- --i - EXHAUST FAN -- ---- _,.. -� Stamp: WARMER TO COLDER SECTION SHALL BE PREVENTED. c O \ I ( 5 E.C. SHALL PROVIDE THE REQUIRED CATS CABLE TO THE HMI PANEL. 11i 1 , iiL,' 1 '71 TF A * z, �` ! 1 , .! I 1I ' - CQNN - E) DB _a _ ' - {� j1 I� YCOI BUFFER TANK ��. -'C" ii 1 1 1 R Q A. P< (2)LOUVERS 1 ._. , w '( 1 3 j__ I. ..._.) r -� T •_LT + o...u• t. �_ R L._.. 1 `3,P G F WA %y o y v S /y� H a T ! , ,e mo R o. fb I 1 '( I t ap ON FUSEDSAFETY 1 TYFjICAL J-OG .e I 1 ` J� 3 I ( ® t DISCONNECT SWITCH 1 I '0.- �'`.b `. 1 -:. :.I j � F "a ' { ry '• E. o �+ 34218 �FSsf�ISTE� `` WEATHBLPROOFBOR - ' tJ, FURNISHED BY DIV.23 WIRED BYDN.26 ; 1 ! FT ��} ,..., AMMONIA/GLYCOL —225AS,325AF{3 ! 2"C,1#4!'0,1)k2�C \ j+V 1 . n \ v l \ J -- I I yj I f : 1 L-_ G�� /ONAL EN E>tP. D3/19/20 6 18 79 - 11 1 7 ,,.f..'.- 20A I20VAC WP1WR % DUPLE( RECEPTACLE �LIMMk J __ - J .. J i / 1 �" • (MI PROTECTED) j - -_. _._ _._..-..._ . _ _...--__ --- T I 1 ]--------.. -= --- - -------i--.. WITH SELFCLOSING / .. _. _ - -- - _..--F. � - .... L- ---- . _'--"-'--'--- --'- - --- Gas COYCit �j __LOUVER_ LOUVER LOUVER _ . - 1 1 f 1 l m pebiai — i I I 1 1 Meter) 1 ROOF F COBELOW (-------- ALL CONDUIT RUNS FOR ROOF MOUNTED EQUIPMENT OR DEVICES SHALL BE RUN ROOF, NOT EXPOSED. PROVIDE AND FILL PATCH POCKETS FOR ALL CONDUIT/ROOF PENETRATIONS, Z i\ PLAN U� • REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL HVAC EQUIPMENTS. lily NORTH � Z 0 ROOF EXHAUST FAN 3 FLOOR POWER PLAN 2 w RECEPTACLE MOUNTING NTS V GENERAL NOTES: G1. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS, BOXES, MISC. FITTINGS, ECT, FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION. 1 1 I 1 O > W o w N i/: //; /,/.:///////; F///// G2. SUBSCRIPTS IN LIGHTING PLAN DENOTES SWITCH. EXAMPLE: 2a, 2 DENOTES CIRCUIT NUMBER AND a DENOTES SWITCH THAT CONTROLS CORRESPONDING LIGHTS. G3. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL -__... , 1 1 1 ---.----.-------- AR-12 / l 2 ; ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE (11 LUX) A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT-CANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT F 1 i _ _I I I I -----..-..-- --'-) 1 EM EXITS Q /1 / 1 (E) PANEL'AR' I , \� 1 3 ' 1 \ `/ I OF 0.06 FOOT-CANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME I 10, //' /// / //' ./// ////% /' ./' 1-Y_-. V///// ,//�/,' % '; /"/,%%/////% • i 1 1' DURATION, A MAXIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO -"` - _ T I / -� -TO -MINIMUM 1 SHALL NOT BE IXCEEDED. H. a ' 1 1 ! 1 EE E D 3 AR-10 XE ,D EE E XE 1 j 73 O m mz c2 a, -I vrp o i GG m o m 2 C x p+ < 5n < a 2 0, (n o Z e Z ° n g a ioN <oco al mrr-- KEY NOTES: 1 1 3 4 I CCUPANCYSENSOR 1 HOMERUN TO PANELBOARD CIRCUITS & RECEPTACLES SHOWN ARE TO BE j j :( (TYPICAL) GLYCOL RM •; TIED/CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS DESIGNATED. 9 5 PHOTOCELL AR-12 (TYPICAL FOR ALL HOMERUN CIRCUITS) 11I g 2 ROUTE CONDUITS OVERHEAD & PROVIDE NECESSARY SUPPORT PER CEC. ):( T1 3 EXIT SIGN AND EMERGENCY LIGHT LIGHTING SHALL BE PROVIDED WITH A BATTERY1 E E E aloE BACK-UP UNIT WITH MINIMUM OF 90 MINUTES AND MUST BE WIRED AHEAD OF ANYi-I SWITCHING DEVICES. ; I i \ \ / , 4 5 ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A CONSTANT HOT CONNECTION TO THE CHARGING LEAD. PROVIDE A PHOTOCELL LIGHTING CONTROL DEVICE CEILING MOUNTED, 6' FROM WINDOW TO CONTROL ALL DAYLIGHT FIXTURES AS REQUIRED. 1 1 I I '� .-....._--__.__. ._....._.. ._ _._... _...._ __. .-..------. __ 1 i , /' - / nECEPlEn F{ /� CITY OF i�I 1�•i1LA _ . FJH Y. NFPA 0 - EC 9r ; • O ` O C 06 BUILDING DIVISION I^ V Z _ _ MIS I I 1 I j 1 \ } —Gas I �t _ 1 ' Meter PERMIT CENTER I I I Project Ma,a er: CR J < j I_J_...----------- ( / Cei VA Ai\ PLAN lir rj NORTH Dale: 8/18/19 scale: m I'IojecI Number 1903079 c SHEET NUMBER LIGHTING PLAN 1 E1O1 re 1 /4"=1'-0" 0 Lu W Lu a re 0 re re 0 V • z • z W 0 w • 0 6 0 0 a w 0 0 re 0 IE) GND BUS (E) CONDUIT & CABLES —47 REFERENCE NOTES: lO (E) TO MAIN SWITCHBOARD 1E600AF 1600AT 3P W/GFCIL (E) DISTRIBUTION BOARD -1 1600A, 3PH, 4W , NEMA 3R, 65 KA SCR - SQUARE D QED-2 SWITCHBOARD r LOAD CALC: 277/480, 30, 4W, 1600A 7 r 1 I 6OAF 1(E) 250AF 000O 60AT ddd 250AT 3P 3P SPARE SPARE (E) DISTRIBUTION BOARD-1"@ 277/480V, 1600 A, 30, 4W COMPRESSOR-1 COMPRESSOR-2 COMPRESSOR-3 = 382 A = 382 A = 189 A CHILLER = 133 A COOLING SYSTEM = 304 A COOLING TOWER 48 A TOTAL LOAD = 1438 AMP 1 T (El ) 5TOAF 500AT c 500AT 3P 3P (2)21/7'C12)21/2" 3# 250 C, 3# 250 KCMIL& KCMIL& 1 #2CU GND. 1 #2CU GND. AMMONIA COMP. 1 382 A 286 KW 3PH, 3W 1 T I r r r r 1 (E) (El �) IE) 512 5 (E) b) (E) ° IEI b) 60AF 6O AF 250AF 5 250AF 40DAF El 125AF 125AF 125AF 60AF 6AF 250AT 250AT ° 400AT 125AT 125AT ° 125AT 6OAT ° 6OAT ° 6OAT 3P 3P 3P 3P 3P 3P 3P 3P 3P 21/2"C, 7'C, 3# 250 3#4/0 AWG KCMIL& &1#2GND. 1#2 CU GND. AMMONIA COMP.2 382 A 286 KW 3PH, 3W AMMONIA COMP.3 189 A 141 KW 3PH, 3W CHILLER COOLING 133 A SYSTEM CP 100KW 304A 3PH, 3W 227.5 KW 3PH, 3W SPARE SPARE SPARE SPARE SPARE a' C,3#500 KCMIL 1-#2 GND. COOLING TOWER 48 A 35.8 KW 3PH, 3W 1 3/4" C. 3#6 AWG 1 #10GND. TO EXISTING MAIN SWITCHBOARD PROVIDE MATCHING BREAKER IN EXISTING SPARE OR SPACE 1 "C. 4# 1 THHN CU + 1 #8 GND (El PANEL 'AR' 60A 12CKT (E) PANEL 'AR' VOLTS:120/208V PHASE: 3 A.I.C. RATING: 22,000 AMP MAIN: 60A MOUNTING: SURFACE WIRE: 4 BUSSING: 125 AMP LOAD ' A -VA B-VA C-VA BKR CT CT BKR A -VA B-VA C-VA ' LOAD EXHAUST HIGH VELOCITY & LOUVER M 1200 20/3 1 2 60/3 1080 N 60A MAIN ---- M 1200 - 3 4 -- 360 N --- M 1200 - 5 6 - 1800 N R L --- ROLL UP DOOR M 1200 20/1 7 8 20/1 360 _.. ROOF GCFI RECEPTACLES LOWVELOCITYFAN M 800 20/1 9 10 20/1 1284 LIGHTING EM EXITS M 200 20/1 11 12 20/1 ' 1284 L LIGHTING PHASE TOTALS: 3840 3644 4484 11968 =TOTAL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 32.0 30.3 37.3 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS: 1.25 X 2568 = 3210 VA C=CONTINUOUS LOADS, OTHER: 1.25 X 0 = 0 VA M=MOTOR LOADS (INCL LGST): 1.00 X 5800 = 5800 VA LARGEST, VA: 0.25 X 12000 = 3000 VA R=RECEPTACLES: 1ST 10K: 1.00 X 360 = 360 VA BALANCE: 0.50 X 0 = 0 VA K=KITCHEN LOADS: OTY: 0 0.65 X 0 = 0 VA N-NONCONTIN000S LOADS, OTHER: 1.00 X 3240 = 3240 VA NOTES: (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 15610 VA = 43.3 AMPERES RECEIVE: CITY OF 11;14 ILA AUG 08 2019 PERMIT CENTER �J-+9 - at-I9 PLUMP ENGINEERING INC. CONSULTING ENGINEERS STRUCTURAL. MECHANICAL PLUMBING, ELECTRICAL. CIVIL, SURVEYING, ARCHITECTURAL 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835, F (714) 385-1834 www.peica.com Stamp: 6/18(19 1227 Andover Park E Tukwila, WA 98188 REVISIONS FOR CITY SUBMITTAL 04/04/19 /� PLAN CHECK /1\ 4122/2019 CLIENT REVISIONS 2 05122/2019 CLIENTREVISIONS 3 \ 06107/2019 OO kPL ,P4C G AUG 27 2019 CRy of Tukwila BuItDt$G DIVISION Project Manager: CR Dote: 6118)19 Scale: Protect NVmbec 1903079 PARTIAL ONE LINE DIAGRAM N 0, N SHEET NUMBER E102 0 s te 0 • 0 N Og 0 u 0 0 O. 6 0 0 N 2 cc x 0 cc 0 3 0 w 0 cc 0 0 0 0 0 CC m 0 0 0 • 0 0 PARTIAL ONE LINE DIAGRAM 1 N.T.S. 6. DEMOLITION NOTES GENERAL NOTES ELECTRICAL SYMBOLS LIST 1. DEMOLITION WORK SHALL BE PERFORMED ACCORDING TO THE ARCHITECTURAL PLANS. 2. ALL MATERIALS, LIGHTING FIXTURES, CONVENIENCE OUTLETS, WIRES, CONDUITS, JUNCTION BOXES AND ALL OTHER DEVICES SHALL CONFORM TO MATCH THE EXISTING CONDITIONS AND EQUIPMENT ON THE JOB SITE, UNLESS OTHERWISE NOTED. 3. REMOVE, REROUTE AND REWIRE EXISTING FIXTURES, RECEPTACLES AND JUNCTION BOXES AND PROVIDE NEW BRANCH CIRCUITS, PANEL FEEDERS, AND DEVICES AS SHOWN ON THE PLANS OR AS REQUIRED FOR A COMPLETE OPERABLE SYSTEM, IN FULL ACCORDANCE AND COMPLIANCE WITH ALL APPLICABLE CODES. 4. ALL EQUIPMENT WHICH IS DISCONNECTED AND REMOVED SHALL BE RETURNED TO THE OWNER. 5. FURNISH AND INSTALL ALL NECESSARY CONDUITS, WIRES, JUNCTION BOXES, BLANK COVER PLATES, ETC. AT ALL LOCATIONS AFFECTED BY RELOCATION OF OUTLETS. WHERE INTERRUPTION OF A CIRCUITS FEEDING EXISTING EQUIPMENT OCCURS DUE TO NEW WORK, THIS CIRCUIT SHALL BE REHABILITATED AND MADE CONTINUOUS FROM PANEL TO LAST EXISTING OUTLET. 7. THE CONTRACTOR SHALL REUSE EXISTING CONDUIT RUNS AND HOMERUNS WHERE POSSIBLE ACCORDING TO CODES HAVING JURISDICTION, PULL NEW WIRES AS REQUIRED. ALL OTHER EXISTING UNUSED CONDUITS AND WIRES SHALL BE REMOVED BACK TO LAST EXISTING OUTLET. 8. UPDATE PANEL DIRECTORIES AT EXISTING PANELS TO REFLECT NEW WORK. 9. THE CONTRACTOR SHALL VERIFY THE CURRENT IN EXISTING FEEDERS AND BRANCH CIRCUITS THAT ARE AFFECTED BY THIS PROJECT PRIOR TO ADDING LOAD TO EXISTING CONDUCTORS, BREAKERS, PANELS, TRANSFORMERS OR SWITCHGEAR. NOTIFY ARCHITECT IMMEDIATELY IF ANY EXISTING EQUIPMENT IS FOUND TO BE OVERLOADED OR WILL BECOME SO IF NEW LOAD IS ADDED. 10. THIS DRAWING IS BASED ON EXISTING DRAWINGS AND OWNER SUPPLIED INFORMATION. THERE HAS BEEN NO VERIFICATION OF PRECISE LOCATIONS, WIRING OR OPERATION OF EXISTING EQUIPMENT. CONTRACTOR SHALL VERIFY ALL JOB CONDITIONS PRIOR TO BID. CONTRACTOR SHALL THOROUGHLY EXAMINE AND VERIFY POINTS OF CONNECTION. ACCESSIBILITY, SIZES, LOCATIONS, ELEVATIONS, ETC. EXISTING CONDITIONS FOUND UNACCEPTABLE OR IN VIOLATION OF CODES AND AUTHORITIES HAVING JURISDICTION SHALL BE CORRECTED. 11. CONTRACTOR SHALL PERFORM ALL VERIFICATION, OBSERVATION,TEST, AND EXAMINATION WORK PRIOR TO THE ACTUAL CONSTRUCTION. HE SHALL ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE ARCHITECT LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. 12. ADDITIONAL LABOR AND MATERIAL REQUIRED TO PROVIDE A COMPLETE AND OPERABLE SYSTEM IN ACCORDANCE WITH CODES AND ALL AUTHORITIES HAVING JURISDICTION NOT LISTED IN THE WRITTEN NOTICE TO THE ARCHITECT SHALL BECOME PART OF THE CONTRACTOR'S WORK JUST AS IF IT WERE INDICATED AND IMPLIED ON THE PLANS. ABBREVIATION AFF AFG AIC BC BKBD CO E,(E) ECP EG EM ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMP INTERRUPTING CURRENT BARE COPPER BACKBOARD CONDUIT ONLY EXISTING ENVIRONMENTAL CONTROL PANEL EQUIPMENT GROUND EMERGENCY FLA FSP GFCI G, GND, GRD IG LCL N,(N) NF NL FULL LOAD AMPS FIRE SUPPRESSION PANEL GROUND FAULT CIRCUIT INTERRUPTER GROUND ISOLATED GROUND LONG CONTINUOUS LOAD NEW NON -FUSED NIGHT LIGHT R,(R) SCC SAD SMD UNO VL WP WT REMOVE, RELOCATE SHORT-CIRCUIT CURRENT SEE ARCHITECTURAL DRAWING SEE MECHANICAL DRAWING UNLESS NOTED OTHERWISE VERIFY LOCATION WEATHERPROOF WATER TIGHT Ei1QCf LLH LED LINEAR N GHDAY DESCRIPTION A cost-effective solid state LED solution for highbay and lowbay applications, replacing up to 250 watt and 400 watt HID fixtures and multi -lamp fluorescent luminaires. FEATURES • >130 Ipw ultra -high efficiency delivers superior performance over fluorescent and HID, saving up to 6096 of energy costs Universal 0-10V driver for continuous dimming 1S Items feature pre -installed adjustable microwave occupancy sensor LISTINGS • UL Listed for damp locations • DesignLights Consortium* Premium Qualified - meets the requirements for the highest DLC qualification for efficacy and lumen maintenance PERFORMANCE • Rated lifetime L70 >100,000 @ 40°C (104°F) >72,000 @ 50°C (122°F) • 4000K, 5000K CCT • CRL 80+ ELECTRICAL • Input voltage: 120-277V, 347-480V • Dimmable power supply (0-10V) • Driver efficiency. >85% • Power Factor: >.9 • THD:<20% THERMAL • -22°F to 122°F (-30°C to 50°C) operating temperature CONSTRUCTION Heavy gauge steel body with welded frame construction resists twisting and bowing • Diffuse frosted acrylic lens to control glare (standard) or optional dear lens for higher light output (sold separately) • 10 ft. Y-toggle aircraft cable mounting hardware included • Built-in 2.5kV surge protection WARRANTY • 5 year limited warranty see eiko.com for warranty details Project name type catalog number comments voltage approved by (ins APPLICATIONS • Warehouses • Manufacturing Plants • Distribution Centers • Grocery Stores • Gymnasiums LLH-1C LLH-2C LLH-3C (sncwr. W:u` optional vme guard assembly) LLH-4C LLH-5C • Indoor Recreational Facilities • Cold Storage • Big Box Retail • Service Repair Centers 11.5111 CCoompllant Cols DLC ORDERING INFORMATION EXAMPLE: LLH-1C-50K-U-15 Model Package CCT Voltage Sensor LLH : LED Linear Highbay 1C - 110W, 14,000Im 2C-162W:21,000Im 3C - 223W; 29,000 Im 5C-321W 4 0001m 40K - 4000K 50K-50JOK U • 120.277V Il V-34/-4Buv 1S - Occupancy Sensor (Blank) - No sensor 1 E K,i USA 800.8'22217I < Jlldtl;l 1 SS9410 sls: I Pilw 1. ELECTRICAL CONTRACTOR SHALL VERIFY VOLTAGE, HORSEPOWER RATINGS, EXACT LOCATIONS OF ALL ELECTRICAL AND OTHER EQUIPMENT PRIOR TO ANY ROUGH -IN. IF DISCREPANCIES ARE NOTED, ADVISE THE ARCHITECT/ENGINEER IMMEDIATELY. 2. SEE RELATED WORK SHOWN ON CONSTRUCTION DOCUMENTS PREPARED BY THE ARCHITECT FOR WORK AND MATERIALS TO BE FURNISHED AND INSTALLED UNDER THIS WORK. 3. LOCATE LIGHT FIXTURES SO AS TO AVOID ALL EQUIPMENT FURNISHED BY OTHER TRADES. COORDINATE ALL ASPECTS OF INSTALLATION PRIOR TO ROUGH -IN. 4. THE ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2014 EDITION OF THE NATIONAL ELECTRICAL CODE, AND ALL. LOCAL CODES HAVING JURISDICTION. 5. ALL LIGHT FIXTURES SHALL BE FURNISHED TO MATCH WITH THE CEILING TYPE IN WHICH THEY ARE INSTALLED. PRIOR TO BID, CONTRACTOR SHALL VERIFY CEILING TYPE INDICATED ON ARCHITECTURAL DRAWINGS. LOCATE ALL LIGHT FIXTURES AS SHOWN ON THE REFLECTED CEILING PLAN. 6. ALL ELECTRICAL EQUIPMENT EXPOSED TO THE WEATHER OR DAMP AND WET AREAS SHALL BE WEATHERPROOF AND HAVE UL LABEL CONSISTENT WITH APPLICATION (NEMA 3R). 7. CONTRACTOR SHALL FURNISH AND INSTALL AN AUXILIARY JUNCTION BOX AT ALL LOCATIONS WHERE A RECESSED LIGHT FIXTURE IS SHOWN WITH MORE THAN EIGHT (8) WIRES CONNECTING OR RUNNING THROUGH IT. SEE NEC 370-6 AND 410-11. 8. CONTRACTOR SHALL OBTAIN THE EQUIPMENT SUPPLIER'S DRAWINGS AND INFORMATION RELATIVE TO THIS PROJECT. HE SHALL UTILIZE THIS INFORMATION FOR EXACT POINTS OF CONNECTION. NO INSTALLATION SHALL BE PERMITTED IN VIOLATION OF MANUFACTURER'S RECOMMENDATIONS. 9. ALL ELECTRICAL EQUIPMENT SHALL BE NEW AND U.L. USTED. 10. LIGHTING FIXTURE CATALOG NUMBERS, VOLTAGES, AND LAMP TYPES ON THE FIXTURES SCHEDULE SHALL BE TREATED AS MINIMUM REQUIREMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION OF ALL VOLTAGES, NUMBERS, LAMP TYPES AND MOUNTINGS. 11. CONTRACTOR SHALL FURNISH AND INSTALL A GROUND WIRE IN ALL CONDUITS. GROUND WIRES MAY NOT BE SHOWN, BUT SHALL BE INCLUDED IN THE ELECTRICAL CONTRACTOR'S BASE BID AND SIZED PER NEC ARTICLE 250-94 AND 250-96, OR AS NOTED ON DRAWINGS. 12. FACILITIES SYSTEMS: AT NO TIME SHALL ANY WORK BE DONE THAT MAY INTERRUPT THE OPERATIONS OF ANY EXISTING FACILITIES WHICH AFFECTS PEOPLE OR EQUIPMENT OUTSIDE THIS SCOPE. IF, IN THE OWNER'S OPINION THERE IS NO POSSIBLE WAY TO AVOID SUCH DISRUPTION, THE CONTRACTOR SHALL CONTACT APPROPRIATE AUTHORITIES, SUBMIT A PLAN FOR APPROVAL TO THOSE RESPONSIBLE. OBTAIN ALL AGREEMENTS, AND THEN COMPLY WITH THOSE AGREED UPON PROCEDURES IN ALL ASPECTS, COORDINATION OF OUTAGE OF ANY SYSTEM SHALL BE EXECUTED WITH SUFFICIENT ADVANCE NOTICE SO AS TO MINIMIZE THE IMPACT OF THE INTERRUPTION OF SERVICES. 13. CONTRACTOR TO TAG/IDENTIFY ALL CONDUCTORS FOR EQUIPMENT INSTALLATION. 14. CONDUIT AND DUCT RUNS ARE SHOWN SCHEMATICALLY. BUILDING CONDITIONS WILL DETERMINE THE ACTUAL RUNS. 15. THE CONTRACTOR MUST VISIT THE SITE PRIOR TO SUBMITTING A BID AND INCLUDE ALL REQUIREMENTS FOR EXISTING FIELD CONDITIONS IN HIS PRICE. 16. ALL SWITCHES AND RECEPTACLES SHALL BE SPECIFICATION GRADE AND 20 AMPERE MINIMUM. WALL - PLATES SHALL BE TYPE 302 STAINLESS STEEL, COLOR OF DEVICES TO BE SELECTED BY ARCHITECT. 17. ALL WIRING SHALL BE INSTALLED IN RACEWAYS. 18. ALL WIRING SHALL BE COPPER, #12 AWG MINIMUM, TYPE THWN AND RATED FOR 600 VOLTS. 19. RACEWAYS ALLOWED: RIGID METAL CONDUIT (REQUIRED IN MECHANICAL, ELECTRICAL AND EQUIPMENT ROOMS), EMT, STEEL FLEXIBLE CONDUIT (MAXIMUM LENGTH SHALL BE 6 FEET) AND PVC COATED METAL CONDUIT (REQUIRED UNDERGROUND AND IN EXISTING SLABS). MINIMUM SIZE HOMERUN SHALL BE 3/4", OTHERWISE 1/2" MINIMUM ALLOWED. ANY RACEWAYS WITH 6 OR MORE CONDUCTORS SHALL BE 3/4" MINIMUM (INCLUDING GROUNDING CONDUCTOR). ALUMINUM FLEXIBLE CONDUIT SHALL NOT BE USED. FLEXIBLE CONDUITS EXCEEDING 6 FEET IN LENGTH SHALL INCLUDE AN GREEN INSULATED CODE -SIZED EQUIPMENT GROUNDING WIRE, PROPERLY BONDED AT EACH END TO MAINTAIN GROUNDING CONTINUITY AS REQUIRED BY CODE. 20. FITTINGS: GALVANIZED STEEL TYPE: SET -SCREW TYPE. 21. SLEEVES: PROVIDE SLEEVES FOR ALL RACEWAYS AND/OR WIRING THROUGH FIRE -RATED WALLS, CEILINGS AND CONCRETE OR STEEL FLOORS. SEAL SLEEVES, AFTER INSTALLING RACEWAYS, WITH APPROVED FIRE -RATING MATERIAL OF EQUAL RATING AS ORIGINAL FIRE -RATING. CABLES AND WIRING THROUGH SLEEVES SHALL BE SEALED ON BOTH ENTRIES. 22. ALL EXISTING AND NEW PANELBOARDS SHALL HAVE TYPE -WRITTEN DIRECTORIES ADDED BY THE CONTRACTOR INDICATING EXISTING CONDITIONS, PRESENT MODIFICATIONS AND NEW WORK. 23. SEAL ALL PENETRATIONS THOUGH FLOOR OR FIRE RATED WALLS WITH FIREPROOFING MATERIAL THAT HAS AN EQUIVALENT FIRE RATING AS THAT OF THE EXISTING CONDITION. 24. THE ELECTRICAL WORK SHALL BE GUARANTEED FOR A PERIOD OF NO LESS THAN ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER. ANY WORK, MATERIAL, OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE UPON WRITTEN NOTIFICATION AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. 25. ALL CONDUIT ONLY (C.O.) SHALL HAVE A PULL WIRE OR ROPE. 26. PROVIDE THE OWNER WITH ONE SET OF COMPLETE ELECTRICAL REPRODUCIBLE DRAWINGS AT THE COMPLETION OF THE JOB SHOWING ACTUAL DIMENSION AND CIRCUITS. 27. ALL BROCHURES, OPERATING MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE TURNED OVER TO THE OWNER AT JOB COMPLETION. 28. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDITION. 29. PATCH, REPAIR, AND PAINT TO MATCH SURROUNDING CONDITION, ANY AREA DAMAGED IN THE COURSE OF THE ELECTRICAL WORK. LIGHTING FIXTURE SCHEDULE CLG. WALL FLR. DESCRIPTION FUSED SWITCH, SIZE AS SHOWN - V.L. DJ NON -FUSED SWITCH, SIZE AS SHOWN - V.L. TIME CLOCK - 7 DAY, SKIP -A -DAY FEATURE WITH MANUAL BY-PASS SWITCH MOTOR OUTLET - IDENTIFICATION SURFACE MOUNTED PANEL 120/208V, 3-PHASE, 4-WIRE 12220 MAIN SWITCHBOARD OR POWER DISTRIBUTION BOARD FLEXIBLE CONNECTION /)/CP')PROVIDE CORD AND PLUG CONDUIT CONCEALED ABOVE CEILING OR IN WALLS CONDUIT UNDER SLAB OR BELOW GRADE, 3/4" MINIMUM HASH MARKS INDICATE QUANTITY OF #12 WIRES IN CONDUIT, EXCEPT NO HASH CONDUIT RUN EXPOSED ---204- MARKS DESIGNATE 2 #12 WIRES. OTHER CONDUIT AND WIRE AS INDICATED 1 HOMERUN TO PANEL "A", CIRCUITS #1 AND #3 - T- TELEPHONE 3/4" C.O. - U.O.N. T1 = I-1/4"C.O.;T2= 1-1/2"C.O. ❑t INDICATES PLAN NOTE NUMBER "1". SEE PLAN CONDUIT STUB OUT, 3/4" MINIMUM - SEE PLANS FOR NOTES O LIGHTING FIXTURE OUTLET - VERIFY MOUNTING WITH FIXTURE SCHEDULE 101 EXIT LIGHT FIXTURE - ARROWS AS SHOWN (90 MINUTES MINIMUM) tet DUPLEX RECEPTACLE AT +18" / I$DUPLEX MOUNTED ABV. COUNTER DOUBLE DUPLEX/ DUPLEX RECEPTACLE AT +18"= CONTROLLED NL NIGHT LIGHT PC CEILING -MOUNTED PHOTOCELL SENSOR 0 JUNCTION BOX AT +18" WALL MOUNTED U.O.N GROUND FAULT INTERRUPTING RECEPTACLE/I=g1= GFCI MOUNTED ABOVE COUNTER / WP ®® DUPLEX/DOUBLE DUPLEX RECEPTACLE, FLUSH FLOOR MOUNTED EICL DUPLEX RECEPTACLE, CEILING MOUNTED DEDICATED RECEPTACLE, 208V, 10 SINGLE POLE SWITCH AT 48" U.O.N. - V.L. 42 43 DOUBLE POLE SWITCH AT +48" U.O.N. - V.L. THREE-WAY SWITCH AT +48" U.O.N. - V.L. t4 FOUR-WAY SWITCH AT +48" U.O.N. - V.L. SYMBOL FIXTURE TYPE WATTAGE VOLTAGE LAMPS DESCRIPTION MANUFACTURER CAT. NO. FINISH MOUNTING REMARK is #M "a" INDICATES OUTLET CONTROLLED AT +48" U.O.N. (PROVIDE SEPARAT SWITCH FOR EACH DESIGNATION) MOTOR CONTROL TOGGLE SWITCH H.P. RATED E 321 120 INTEGRAL 40K LED 1'x4' LED LINEAR HIGHBAY LIGHT FIXTURE EIKO LLH-5C-50K-U-1 S WHITE SURFACE LED DRIVER 0-10V DIMMING TO 10% 00 CEILING -MOUNTED MOTION/OCCUPANCY SENSOR EE 321 120 SAME AS TYPE "E" EXCEPT WITH EMERGENCY LED DRIVER, AND WITH MIN. OF 90 MINUTES BATTERY BACK-UP. 2 F� 20V t SPECIFICATIONS; INFORMATION ADJACENT TO CALL -OUT INDICATES HORSE DENOTES MECHANICAL EQUIPMENT SEE MECHANICAL DRAWINGS FOR EXACT POWER (H.P.) AND VOLTAGE RATING XE 2.3 120 LED EXIT SIGN WITH 90 MINUTES BATTERY BACK-UP. LITHONIA LQMSW3R120ELN WHITE UNIVERSAL SEPARATE. PERMIT aE rRED FOR: r Mecharlicei Jw E Iectf1cal Plumbing rGas Piping City of TUkwiia BUILDING DIVISION (E) PANEL 'AR' VOLTS:120/208V PHASE: 3 .A.I C. RATING: 22,000 AMP MAIN 60A MOUNTING: SURFACE • .WIRE: 4 BUSSING:125AMP LOAD • A -VA B-VA C-VA BKR CT CT BKR A -VA B-VA C-VA • LOAD EXHAUST HIGH VELOCITY & LOUVER M 1200 q v g, T : 20/3 1 2 60/3 1080 '-��, c : f} N 60A MAIN -- M ; X ' '' 1200u� - 3 4 - ; 360 P S$ , 1. N ---- M •R2 1200 - 5 6 - ;1,+ s 1800 N -... ROLL UP DOOR M 1200;T . s+tF= 20/1 7 8 20/1 360 1° 6k 1 ;i R ROOF GCFI RECEPTACLES LOW VELOCITY FAN M T r" 800 ;3x� 20/1 9 10 20/1 ;; i34,t 1284 • i(L LIGHTING EM EXITS Ma, e..- ,s:"4?"s 200 20/1 11 12 20/1 ., ^ 1284 L LIGHTING PHASE TOTALS: 3840 3644 4484 11968 =TOTAL CONNECTED LOAD • (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 32.0 30.3 37.3 *DEMAND LOAD CALCULATION: • L=LIGHTING LOADS: 1.25 X 2568 = 3210 VA C=CONTINUOUS LOADS, OTHER: 1.25 X 0 = 0 VA M=MOTOR LOADS (INCL LGST): 1.03 X 5800 = 5800 VA LARGEST, VA: 0.25 X 12000 '= 3000 VA R=RECEPTACLES: 1ST 10K: 1.00 X 360 = 360 VA BALANCE: 0.50 X 0 = 0 VA K=KITCHEN LOADS: QTY: 0 0.65' X 0 = 0 VA N=NONCONTINUOUS LOADS, OTHER: • 1.00 X 3240 = 3240 VA NOTES: (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 15610 VA = 43.3 AMPERES TO EXISTING MAIN SWITCHBOARD PROVIDE MATCHING BREAKER IN EXISTING SPARE OR SPACE (E) PANEL 'AR' 60A 12CKT •1`);uniS `toes 1"C. 4# 1 THHN CU + 1 #8 GND DP MOUNT JUNCTION BOX WITH BLANK COVER PLATE 6" ABOVE ACCESSIBLE CEILING FOR MODULAR FURNITURE POWER POLE BY OWNER. "P" INDICATES POWER SUPPLY, "C" INDICATES DATA AND TELEPHONE SUPPLY 4/0 PULL BOX 4aD DIMMER/ OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCHING AT +4E' (120 VOLT) OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH SINGLE LEVEL SWITCHING AT+48" (120 VOLT) 3ab OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH BI-LEVEL SWITCHING AT+48" (120 VOLT) iabD DIMMER/OCCUPANCY AUTOMATIC WALL SWITCH SENSOR WITH BI-LEVEL SWITCHING AT+48" (120 VOLT) 7 DATA/TELEPHONE OUTLET, WALL -MOUNTED DATA OUTLET, WALL -MOUNTED SHEET LEGEND E001 GENERAL NOTES, SYMBOLS LIST, LIGHT FIXTURE/PANEL SCHED1,fj1.Ft' & SLD } E101 LIGHTING & ROOF POWER PLAN a • SINGLE LINE DIAGRAM NOTES Si. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDUITS ALL NEW. S2. CONDUCTOR SHALL BE COPPER. S3. ALL EQUPMENT AND CONDUITS SHOWN ARE EXISTING UNLESS NOTED OTHERM'ISE. S4. VISIT SITE BEFORE BIDDING PROJECT TO SEE ALL EXISTING CONDUITS. QUALIFY ANY EXISTING CONDITIONS IN BID THAT WERE FOUND DURING SITE VISIT. IF NO SITE VISIT IS DONE IT WILL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO DO PROJECT COMPLETE PER PLANS WITH NO EXTRA COST CIT OF TUKW1LA AY 2 9 2019 PEF MIT CENTER EL1.OL.ILI9 Inc PLUMP ENGINEERING INC. CONSULTING ENGINEERS STRUCTURAL MECHANICAL, PLUMBING. ELECTRICAL CIVIL SURVEYING, ARCHITECTURAL 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835, F (714) 385-1834 www.peica.com 5, Stamp: PR D A, p� a N OE gASi, (✓� k�yc s 1 S ,p 34218 p "krs ONA LT f t*) EXP. 03/19/20 5/22/19 o 4c-_� )M Al REVISIONS FOR CITY SUBMITTAL 04104/19 H PLAN CHECK 1 4122)2019 s-i "" 1 0 CLIENT REVISIONS 2 05/22/2019 ( C/j J • � LJJ J 0D CO LL1 S v) U � W' OZ Z < J CI- LL1 CZ CZ L11 Z I- L1J %< P'oject Manager: CR Dote: 5/22/19 ai Scats: 15 i ' P-oject Wmber. 1903079 m 4 H SHEET NUMBER , EOO1 0 W K Cle 1- 0 n 0 01 x 0 c. 0 0 GENERAL NOTES: G1. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS BOXES, MISC. FITTINGS, ECT, FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION AND C.E.C. (2016). G2. ALL PENETRATIONS THROUGH FIRE WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. G3. WHERE A SHARED NEUTRAL CONDUCTOR IS USED FOR MULTIPLE BRANCH CIRCUITS, CONTRACTOR SHALL GROUP CIRCUITS TOGETHER IN PANEL AND PROVIDE A MANUFACTURER FURNISHED HANDLE -TIE TO SIMULTANEOUSLY TRIP ALL OF THE CIRCUITS SHARING THE NEUTRAL. G4. VOLTAGE DROP IN ACCORDANCE WITH ENERGY CONSERVATION CODE 505.7.3. G5. ALL 120V CIRCUIT LENGHTS GREATER THAN 100 FT SHALL BE INCREASED TO #10 AWG AND TO #8 AWG WHEN GREATER THAN 160 FT. INCREASE CONDUIT SIZE FOR 40% FILL. /////////////////////// i I 1-- , i % ; ; PANEL 'AR' / (E) AR-7 I 2 / ,' , ///i,1///// ///_// A '. Lr//�,I 0 /////7/////////r/////// /////./// 3 _ _ - ---� — -- i •I 1 cores i I CO+W j 3 C P e AR-1,3,5 ROLL UP DOOR BecMadAMcn cieo�Se re / I I i - 20AF 3P • KEY NOTES: WP/ I I 1 2 3 4 HOMERUN TO PANELBOARD CIRCUITS & RECEPTACLES SHOWN ARE TO BE TIED/CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS DESIGNATED. (TYPICAL FOR ALL HOMERUN CIRCUITS) ELECTRICAL CONTRACTOR TO PROVIDE SERVICE DISCONNECTS. PROVIDE WEATHERPROOF GFCI ROOF MOUNTED SERVICE RECEPTACLES LOCATED WITHIN 25 FEET OF ANY MECHANICAL EQUIPMENT. SEALING: WHERE PORTIONS OF INTERIOR RACEWAY SYSTEM ARE EXPOSED TO WIDELY DIFFERENT TEMPERATURES, CIRCULATION OF AIR FROM WARMER TO COLDER SECTION SHALL BE PREVENTED. - - i /' .019 M EXHAUST FAN LOUVER I EXHAUST FAN AR-9 / / �/ I i P III, GEC' WP ', O GEC! GLYCl11LlRM AUST FAN ' EXHAUST FAN / WP - COS) % (2)LOUVERS it 1,- (TYPICAL)C AR-8 -- / l 1 (TYPICAL) NON -FUSED SAFETY DISCONNECT SWITCH 1. FURNISHED BY DIV. 23 WIRED BY DN. 26 WEATHERPROOF BOX e J J G r....—'] 20A, 12ovAC //� aitt /rT , Gas Pik (GFCI PROTECTED) ) LOUVER LOUVER LOUVER 1 Meter WffH SELF -CLOSING COVER 'r '%s_ I ROOF ALL CONDUIT RUNS FOR ROOF MOUNTED EQUIPMENT BELOW ROOF, NOT EXPOSED. PROVIDE AND FILL PATCH OR DEVICES SHALL BE RUN POCKETS FOR ALL CONDUIT/ROOF PENETRATIONS. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL HVAC EQUIPMENTS. Ali\ PLAN litp/ NORTH ROOF EXHAUST FAN 3 ROOF POWER PLAN 2 RECEPTACLE MOUNTING NTS ' GENERAL NOTES: G1. G2. G3. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS, BOXES, MISC. FITTINGS, ECT, FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION. SUBSCRIPTS IN LIGHTING PLAN DENOTES SWITCH. EXAMPLE: 2a, 2 DENOTES CIRCUIT NUMBER AND a DENOTES SWITCH THAT CONTROLS CORRESPONDING LIGHTS. EMERGENCY UGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE (11 LUX) A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT-CANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM -TO -MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO I SHALL NOT BE EXCEEDED. j ' AR- orV. , .<i - «.. - ,/ II ' EM EX �, // (E) PANEL 'AR' 3 e "j/ ' — /� �/% /f////�/��/////f/1/// � // / t///////////// ///////// ///// / c> I I c!_J �� I ;.,�, c 3Ar j ; c L_ ' rI 5'>`� M D 3 1 __ XE ( / j 1 �«ol����.on�. EE --Ait to , EL EE --� I E 1 1 XEI _ Wei KEY NOTES: \-OCCUPANCYSENSOR -El l (TYPICAL) GLYCOL RM / _ I 1 2 3 4 5 I HOMERUN TO PANELBOARD CIRCUITS & RECEPTACLES SHOWN ARE TO BE TIED/CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS DESIGNATED. (TYPICAL FOR ALL HOMERUN CIRCUITS) ROUTE CONDUITS OVERHEAD & PROVIDE NECESSARY SUPPORT PER CEC. EXIT SIGN AND EMERGENCY LIGHT LIGHTING SHALL BE PROVIDED WITH A BATTERY BACK-UP UNIT WITH MINIMUM OF 90 MINUTES AND MUST BE WIRED AHEAD OF ANY SWITCHING DEVICES. ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A CONSTANT HOT CONNECTION TO THE CHARGING LEAD. PROVIDE A PHOTOCELL LIGHTING CONTROL DEVICE CEILING MOUNTED, 6' FROM WINDOW TO CONTROL ALL DAYLIGHT FIXTURES AS REQUIRED. 5 PHOTOCELL AR-12 / F fi`7'''� OHY - f._ i ad NNW )2( - . 7 'p�� qq !' f �II.ILA �u j ' :T� " li ;iir iOi E(-;� el YCOL &IffER TANK �� 1 I . -•. '- lv vill - - - e - - a I -•-�. .� e N i ---.� -- a � -;�SR'�+)���� _ _,, .. ,,.s,l Ais ; muhl il�q.:At 0101.o. .� rl _ q" 1 I Jt ! 11 S •ram.,.. ..,. ` ' ?`- '' 1 _ 1 i i 41 i� ? t 1 • • ` "_'>.•�-~--_ _ _ - . - _ - ice u.. —, ��"� --� --f'• ..- , - -" 6ea+ — _ / ......_ __ �- - - - -� �_ (�� — — (I , A�HMCMWGLYCOL=�, Y CHUM _Q _ Li ,�, al i • ' ' / RECEIVED CITY OF TliKWtLA �0' v .�,'/p MAY 29 2019 p PERMIT CENTER Gas Pip 1 . Meter- 411\ foolosek aro Dtitikl, PLAN IR/ NORTH LIGHTING PLAN 1 1 /411=1'-0" inc PLUMP ENGINEERING INC. CONSULTING ENGINEERS STRUCTURAL MECHANICAL, PLUMBING. ELECTRICAL. CIVIL. SURVEYING, ARCHITECTURAL 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92805 P (714) 385-1835, F (714) 385-1834 www.peica.com 5tigi.t.„ Stamp: it,/ p,R a A. p F WASy "E a ,p 34215cC/Sp �� ��ss E NA 0\G\�rxP. LT 03/19/20 5/22/19 RAGI )M A REVISIONS Sheet Title: LIGHTING & ROOF POWER PLANS FOR CITY SUBMITTAL 04/04/19 APLAN CHECK 1 4/2212019 nCLIENT REVISIONS 2 05/2212019 PROIect MOnoge,: ^� Date' 5/22/1V9` Stole: Proect Number 1903079 SHEET NUMBER E1O1 w n oe grt 0 x oe 0. 0 u