HomeMy WebLinkAboutPermit EL19-0460 - BOEING #13-03 - YARD - REPLACE EXISTING FEEDERS WITH NEW; REPLACE EXISTING, WORN OUT DISCONNECTS WITH NEW; UPGRADEBOEING #13-03 YARD 10002 E MARGINAL WAY S ELI 9-0460 Parcel No: Address: City of Tukwila a ent of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 306-438'935V Web site: http://www.TukwilaWA.gov 0003400021 10002 E MARGINAL WAY S Project Name: BOEING #13-03 - YARD ELECTRICAL PERMIT Permit Number: EL19'0460 Issue Date: 6/13/2019 Permit Expires On: 12/10/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE P}BOX 37O7M/C28-5BPROPERTY TAX DEPT, SEATTLE, WA, 98124 JEFFREY MCNEAL 15135NE92ST'REDMOND, WA, 98052 Phone: (425) 814-6000 SEQUOYAH ELECTRIC LLC (ELECTRICAL) Phone: (425) 814-6000 15135 NE 92NDST,REDMOND, WA, 98052-3519 SEQUOEL977S9 Expiration Date: 1/30/2021 DESCRIPTION OF WORK: REPLACE EXISTING FEEDERS WITH NEW; REPLACE EXISTING, WORN OUT DISCONNECTS WITH NEW;UPGRADE ILLEGAL WIRING METHODS TO CLA5S 1, DIV 1 HAZERDOUS METHODS (THROUGH 13-03 BUILDING OUT EAST DOOR TOFLIGHT LINE, NORTH TONORTH EAST OFCORNER) SE[l#ll640. Valuation of single family: $0.00 Valuation of mf/comm: $241,000.O0 Type of Work: REMODEL Fees Collected: $4,702.95 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2015International Fuel Gas Code: Lt._ Permit Center Authorized Signature: ) 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: c Date: /.? This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: 05(31 I Date Application Expires: 1 l (31 (1 Q (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: King Co Assessor's Tax No.:6603 `600,2/ 10002 East Marginal Way South, through 13-03 bl Tenant Name: Boeing PROPERTY OWNER Name: The Boeing Company Address: PO Box 3707 M/C 20-200 Property City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Jeffrey McNeal Address: 15135 NE 92nd Street City: Redmond State: WA Zip: 98052 Phone: (425) 766-3414 Fax: (425) 814-6003 Email: Suite Number: 3-03 BLl Floor: Flight Line New Tenant: ❑ Yes ®..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Sequoyah Electric LLC Address: 15135 NE 92nd St City: Redmond State: WA Zip: 98052 Phone: (425) 814-6000 Fax: (425) 814-6003 Contr Reg No.: SEQUOEL977S9 Exp Date: 12/31/2016 Tukwila Business License No.;. 0994355 Valuation of Project (contractor's bid price): $ 241,000 Scope of Work (please provide detailed information): Replace existing feeders with new; Pepl'ace existing, worn out disconnects witrh new; Upgrade illegal wiring methods to Class 1, Div 1 hazardous methods (Through 13-�'3 building out East Door to Flight Line, Norht to North East Corner) — cl. ltbg© Will service be altered? ❑ Yes ® No Adding more than 50 amps? ❑ Yes [J No Type of Use: Flight Line Type of work: ❑ New 0 Addition 0 Service Change ® Remodel 0 Tenant Improvement O Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy 2 Seattle City Light n:\Applications\Forms-Applications On Line \2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 1 of 2 4 RESIDENTIAL NEW RESIDENTIAL SERVICE O New single family dwc]lings $152.85 (including an attac garage) O Garages, pools, s and outbuildings $81.90 ea O Low volta• systems , furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES O Service change or alteration $81,90 (no added/altered circuits) O Service change with added/altered circuits $81.90 number of added circ s $11.55 ea O Circuits added/altered withi service change $54.60 (up to 5 circuits) O Circuits added/al without service change $54.60 (6 or mor $7.65 ea O Meter/m repair $68.25 O Lo oltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ▪ Temporary service (residential) $65.00 O Temporary service (generator) $80.90 O Manufactured/mobile home service $86.25 (excluding garage or outbuilding) O Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PE IT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Print Name: /4/Vere7.—e4 Mailing Address: 15135 NE 92nd St. City Date: 05/3a/2019 Day Telephone: (425) 766-1030 Redmond WA 98052 11:1ApplicationsWerms-Applications On Line \2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $3,798.54 EL19-0460 Address: 10002 E MARGINAL WAY S Apn: 0003400021 $3,798.54 Credit Card Fee $110.64 Credit Card Fee R000.369.908.00.00 0,00 $110.64 ELECTRICAL$3,512.29 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $3,512.29 TECHNOLOGY FEE $175.61 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17887 R000.322.900.04.00 0.00 $175.61 $3,798.54 Date Paid: Thursday, June 13, 2019 Paid By: SEQUOYAH PERMITS Pay Method: CREDIT CARD 054603 Printed: Thursday, June 13, 2019 11:57 AM 1 of 1 CriWSYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 286-133'1870 CITY OF TUKWILA Date: 06/13/I819 1I:57:17 AM CREDIT CARD SALE VISA CARD NUMBER: *+.********8707 � TRAN AMOUNT: $3,798.54 APPROVAL CD: 054603 RECORD #: 000 CLERK ID: Bill Thank youl Customer Copy Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $904.41 EL19-0460 Address: 10002 E MARGINAL WAY S BLDG 13-03 Apn: 0003400021 $904.41 Credit Card Fee $26.34 Credit Card Fee R000.369 908.00 00 0,00 $26.34 ELECTRICAL $878.07 PLAN CHECK FEE R000.345.832.00 TOTAL FEES PAID BY RECEIPT: R17770 00 0.00 $878,07 $904.41 Date Paid: Friday, May 31, 2019 Paid By: SEQUOYAH PERMITS Pay Method: CREDIT CARD 078438 Printed: Friday, May 31, 2019 10:00 AM 1 of 1 YSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206'433'1870 CITY OF TUKWILA Date: 05/31/2019 09:59:48 AM CREDIT CARD SALE VISA CARD NUMBER: **********8707 K TRAN AMOUNT: $904.41 APPROVAL CD: 078438 RECORD #: 000 CLERK ID: Laurie Thank you! Customer Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. P RO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)_ 431-3670 Permit Inspection Request Line (206) 438-9350 Project: .rt I Type of Inspection: Address: Date Called: Special Instructions: I0 rt tid3 NU()Phone `Date Wanted: a.m. p.m. Requester: No: fir" � a+ ► V" f Approved per applicable codes. Corrections required prior to approval. COMMENT Inspector: Date: REINSPECTIO FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd, Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P T NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Type of Inspection: T Address: A ->e" Date Called: Special Instructions: 1 Date Wanted: a.m. p.m. Requester: Phone No: tf2A..-- ( e..7, i WO' Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4e5PP A ->e" . . Inspector: Date,,, REINSPECT FEE REQUIRED. Prior to next inspection, fe must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. I'iERMtT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: 0 /.3 0 Type of Inspection: , Address: Date Called: Special instructions: Date Wanted: a.m. P.m. 'Requester: (10(6 ii Phone No: 'f 2G, L(o l�J © Approved per applicable codes. COMMENTS: poCorrections required prior to approval. nspecto Date: 0 2 REINSPECTI©FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 *Project: .rte Type f nspection:', , Address: — Date al d: Special Instructions: 4-1 •. -Date Wanted: a.m. p.m.. Requester: Phone No: VA-- 766 _ le -05 I Approved per applicable codes. orrections required prior to approval. COMMENTS: ns pector: Date: 0 REINSPECTIO FEE REQUIRED. Prior to next inspection, fee ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 0 FILE ELECTRICAL PANEL SCHEDULE Panel Designation 72E Panel Type IEM SWITCHBOARD Main Bkr Rating 200A Panel Rating Ref, Dwg.No. Revision Engineer 225A, 480V, 3PH, 3W 13 -YD -E310 10/31/2018 72E.xls SUB 97F4 Location, bldg, East Utility Vault Stall 72 col. Date Installed Feeder Size Fed From SHORT CKT. RTG. Revised Ckt Date Revised Job Number TBD 3"C-(3)#35Cikcmil, #6G 745/55, 57, 59 , Isym 65k 38.8k AVAIL 10.31.18 W5581119 Ckt Breaker Type Frame Trip Wire Size Load Served o d A Ph A Cable No./Location la 3b 5c 7a 9b 11c SGLA 100A SGLA 15A 90A 3P 15A 3P #3 #3 #3 #12 #12 #12 30kVA MPZ PANELBOARD 72EMPZ 3KVA TRANSFORMER 4 4 13a 15b 17c SGLA 30A 30A 3P SPARE MEM STALL 72 (EAST) MUSEUM OF FLIGHT GATE 19a 21b 23c 25a 27b 29c 31a 33b 35c 37a 39b 41c 43a 45b 47c 49a 51b 53c SGLA 20A 30A 3P SPARE SPACE SPACE SPACE SPACE SPACE • #568 STALL 74 2a 4b 6c SGLA 60A 60A 3P SPARE 8a 10b 12c SGLA 60A 60A 3P SPARE 111111111 11111111111 14a 16b 18c SPACE MEM REVIEWED FOIC COMPLIANC WI NFPA 70 - NEC JUN 1 2 2019 City of Tukwila UIL IN DIVISIO 20a 22b 24c 26a 28b 30c 32a 34b 36c 28a SPACE 1111111111 SPACE RECEIVED CITY OF TUKWILA SPACE MAY 3 1 2019 PERMIT CENTER Page 1 of 2 • ; Panel Designation Panel Type Main Bkr Rating Panel Rating Ref. Dwg,No. Revision Engineer 40b 42c ELECTRICAL PANEL SCHEDULE 10/31/2018 72E.xls SUB 97F4 72E Location, bldg. East Utility Vault Stall 72 IEM SWITCHBOARD 200A 225A, 480V, 3PH, 3W 13 -YD -E310 SPACE col. Date Installed TBD Feeder Size 3"C-(3)#35(1kcmil, #6G Fed From 74S/55, 57, 59 SHORT CKT. RTG., Isym 65k 38.8k AVAIL Revised Ckt Date Revised 10.31.18 Job Number W5581119 44a 46b 48c SPACE 50a 52c 56c SPACE PHASE TOTAL AMPS TOTAL CONN LOAD Page 2 of 2 4 4 4 3 KVA Location : MDC STALL 72 EAST Panel Type : SqD MPZ Electrical Panel Schedule Building : 13YD-N Panel Name : AIC Rating (amps) : 25,000 72EMPZ Installation Date : Main Feeders Rev Date Bkr : FAL34090/ 003100 Rating : 83A, 120/208, 3PH, 4W Br Bkrs : SqD 'QO' : 3#3, #8G From : PNL 72E/1,3,5 FIL Revised Circuits : NEW PANEL Date Revised : 10/31/18 Engineer : Casne Engineering, Job number : W5581119 Ref Dwg : 13-YRD-E624 Rev : Ckt No Breaker - Amps/Poles Wire Size Load Description Amps Location a la / #10 - 8a SqD '00' - 20/1 3b SqD 'QO' - 30/3 #10 (1) 30A T -L RE PT - CABANA POWER SqD 'QO' - 20/1 'SPARE 5c / #10 - 14a SqD '00' - 20/1 7a / #10 SqD '00'-20/1 a T' SPARE 9b SqD '00' 30/3 #10 (1) 3OA T -L RECPT, - CABANA POWER 20a 11c 13a i #10 24c SqD GFCI - 30/1 q #10 (1) 30A T -L RECEPTACLE 24c 15b SqD 'QO' GFCI- 30/1 #10 (1) 30A T -L RECEPTACLE 17c SqD 'QO' GFCI - 15/1 #12 VAULT WATER PIPING HEAT TRACE 19a / SPACE 21b / SPACE . ._ 23c / SPACE Notes : MDC STALL 72 POWER UPGRADE �{ VI WEDFFO UANC NFPA 70 -- P4EC JUN 122019 City of Tukwila UILDING DIVISION RECEIVED CITY OF TUKWILA MkAY 3 1 2019 PERMIT CENTER EL\ 0460 2a SqD 00' GFCI - 30/1 #10 (1) 30A T -L RECEPTACLE 4b Sq '00' GFCI - 30/1 #10 (1) 30A T -L RECEPTACLE 6c SgD'Q0' - 20/1 #12 (1) DUPLEX GFCI RECEPTACLE 8a SqD '00' - 20/1 SPARE 10b SqD 'QO' - 20/1 'SPARE 12c SqD 'QO' - 20/1 (SPARE SPARE 14a SqD '00' - 20/1 16b SqD '00'-20/1 SPARE 18c / SPACE 20a / SPACE 24c / SPACE 24c / SPACE Notes : MDC STALL 72 POWER UPGRADE �{ VI WEDFFO UANC NFPA 70 -- P4EC JUN 122019 City of Tukwila UILDING DIVISION RECEIVED CITY OF TUKWILA MkAY 3 1 2019 PERMIT CENTER EL\ 0460 FILE ELECTRICAL PANEL SCHEDULE Panel Designation 74S Panel Type Main Bkr Rating Panel Rating Ref, Dwg.No. Revision Engineer IEM SWITCHBOARD MAIN LUGS ONLY 1600A, 480V, 3PH, 3W 13 -YD -E310, 13 -YD -E311 D, E CASNE 10/31/2018 74S,XLS SUB 97F4 Location, bldg. Service Island 74/76 col. Date Installed 9/97 Feeder Size (4)4"C-(4)#750MCM per phase Fed From Northeast Substation #97F4 SHORT CKT. RTG., Isym 65k 38.8k AVAIL Revised Ckt Date Revised Job Number 55,56,57,58,59,60 10.31.18 W5581119 Ckt Breaker Type Wire Size Load Served Load Arms Cable No./Location Frame Trip Ph A Ph B Ph C la SGLA 600A 600A 3P (2) 350MCM Feeds F/A-22 AIL/MFC (13-09 Bldg iii::1lil. l.liill] STALL 74.) 3bIiII "iiiiiiii 5c iilii i'iiii•il 7a 320 #561 —9—b— SGLA 600A 400A 3P (2)#4/0 400A RECEPT ii:iii:iii 320 " - STALL 74 11cIliiMilliy 320 13a SFLA 200A 200A RECEPT 160 ii!i!;11 i'lil #568 STALL 74 -- #4/0 lii "l'i'l'i'lli —57 250A 3P : ill.:iii; 160 19a SPACE W/250A HDWR.nk i -Mi eilil 21b ili.ii: :••+4':iiii 23c 25a SELA 100A 100A 3P 100A RECEPT 80 t.iiill'illIiiIMi''' . #572 STALL 74 27b #2 80 i!iMii 29c . i iiiiiililii 80 31a SELA 60A 60A 3P CREW SHELTER #1 52 11a11 l'iiiii #578 STALL 74 33b# 4 lliliiiiii liiiiiiiiiiii 35c i!i]iiil .,,t, iiiiigi 52 37a SELA 60A 60A 3P 60A RECEPT i-iiiii iiMI #575 STALL 74 39b # 4 ilililli 48 Illilllilliiii 41c i. .ii qIiiii 48 43a SELA 30A 30A 3 P 30A RECEPT 24 *i.M:ill'iiill #579 STALL 74 45b # 8 liiillii'l 24 47c ..ii lijiill;i4 24 49a SE0ALA 3 30A 3P #10 LIGHTING WEST SIDE & NORTH SIDE 2lilllilliill llilililiil #684 STALL 74 --- 51 b 53c # 10 i:ii:.:ili E:iiii2 SGLA 600A 200A 3P STALL 72 57b 350KCMIL 200A DISTRIBUTION PANEL 72E ilillIlil-i 59c lililillIli',jillilirtill EV E ED FO 61aUMP SPACE W/100A HDWR VVITHLIANC NFPA 70 - NEC 63b lilililililli" ' liillill , il SPACE W/100A HDWR JUN I 2 2019 69b 71c ' - 73a .-.:,.. ilill.ill:: - iiii: • + •z: ,illUILDINGIVI City of Tukivila , DIVISION 75b SPACE W/100A HDWR . .: • . : : i:- -,,,,...:. „ . _— — 77c liQliiilL, 79a SPACE W/100A HDWR lliT:iiiiiiIIMlii 81b 83c ii-!iiiiiiiiiil 85a SPACE W/100A HDWR RECEIVED lli!Itlilill 87b ;iiiiiiiii iiill 89c CITY OF TUKWILA MAY 3 1 2019 pER„„,,Tagc.,,,TER ELECTRICAL PANEL SCHEDULE 10/31/2018 74S.XLS SUB 97F4 Panel Designation 74S Location, bldg. Service Island 74/76 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer IEM SWITCHBOARD MAIN LUGS ONLY 1600A, 480V, 3PH, 3W 13 -YD -E310, 13 -YD -E311 D, E CASNE col. Date Installed 9/97 Feeder Size (4)4"C-(4)#750MCM per phase Fed From Northeast Substation #97F4 SHORT CKT, RTG., Isym 65k 38.8k AVAIL Revised Ckt 55,56,57,58,59,60 Date Revised 10.31.18 Job Number W5581119 Ckt Breaker Type Frame Trip Wire Size Load Served Load Am DS Ph C Ph A Ph B Cable No./Location 2a 4b 6c SGLA 600A 400A 3P (2)#4/0 400A RECEPT 320 320 320 #562 STALL 74 8a 10b 12c SGLA 600A 400A 3P (2)#4/0 400A RECEPT 320 320 320 #567 STALL 74 14a 16b 18c SFLA 250A 200A 3P #4/0 200A RECEPT 160 160 160 #569 STALL 74 20a 22b 24c SPACE W/250A HDWR 26a 28b 30c SELA 100A 100A 3P SPARE 32a 34b 36c SELA 60A 60A 3P # 4 CREW SHELTER #2 52 52 #577 STALL 74 38a 40b 42c SELA 60A 60A 3P #4 60A RECEPT 48 48 48 #576 STALL 74 44a 46b 48c SELA 30A 30A 3P 30A RECEPT 2 #8 And Gate Operator Motor 2 2 #580 STALL 74 50a 52b 54c SELA 30A 30A 3P SPARE 56a 58b 60c SGLA 600A 400A 3P 500KCMIL (3)200A RECEPTs STALL 72 62a 64b 66c SPACE W/100A HDWR 68a 70b 72c SPACE W/100A HDWR !1!111!1!1111 74a 76b 78c SPACE W/100A HDWR 80a 82b 84c 86a 88b 90c SPACE W/100A HDWR SPACE W/100A HDWR PHASE TOTAL AMPS TOTAL CONN LOAD Page 2 of 2 1588 1482 1588 1319 KVA F ELECTRICAL PANEL SCHEDULE Panel Designation 76N Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer IEM SWITCHBOARD MAIN LUGS ONLY 1600A, 480V, 3PH, 3W 13 -YD -E310, 13 -YD -E311 D, E CASNE 10/31/2018 76NALS SUB 96F1 Location, bldg. Service Island 74/76 col. Date Installed 8/97 Feeder Size (4)4"C-(4)#750MCM per phase Fed From Northeast Substation #96F1 SHORT CKT. RTG., Isym 65k 39k AVAIL Revised Ckt Date Revised Job Number 55, 57 59 10.31.18 W5581119 Ckt Breaker Type Wire Size Load Served Load Amos Cable No./Location Frame Trip Ph A Ph El Ph C la20 ililil'-'Vilill #563 3b SGLA 400A (2)#4/0 400A RECEPT 320 '':,.. i:i STALL 76 50 600A 3P iiiiiii 320 7a SGLA 600A 400A 3P 400A RECEPT 320 iiiiiiiii -,, #566 STALL 74 9b (2)#4/0 iiii! 320 11c 320 13a SFLA 250A 200A 3P 200A RECEPT 160 iiiiiiiiiiiiIiiii #570 STALL 74 15b # 4/0 160 iiiiiiiiilii 17ciii iiiiIiill. 160 19a SFLA 250A 200A 3P 200A RECEPT 160 iiiiiiillrieii.::' .166 #581 STALL 74 21b # 4/0 ,:::::; 160 25a SELA 100A 100A 3P 100A RECEPT 80 iiIiiIii iiillili #573 STALL 74 27b # 2 iiiiliiiiii 80 29c iiiiiiiiili iiiiiiiiii'ili 31a SELA 60A 60A 3P 60A RECEPT 48 liiiiiiiiiii: iiii #583 STALL 76 33b # 4 iiiii iii 48 35c ili.iiiiiii iiiiiiiiiiii48 SELA 60A spare 39b 7.7 80A 3F) -.F_ ii; 43a SELA 30A 30A 3 P 30A RECEPT 24 iiiiiiiiiii; ' #582 45b # 8 i iiiiiiii 24 STALL 76 47c liiiiitilliiiillii 24 49a SELA 30A # 10 LIGHTING SOUTH SIDE 2 liiiiiiiiiir:iiii''' #686 5sz. 30A 3P #10 iiiiili illiiiliiii 2 55a SGLA 400A 400A RECEPT 320 iiiiiiiiiii;:i i iiiii STALL 72 57b600A 500KCMIL i.il:liElii 320 :I i 59c 3P 320 61a SPACE W/100A HDWR - 63b ilii . • , 65c iiiiiiiiill 67a SPACE W/100A HDWR il!il 'l i i F° 01g41,16AWNEWtTh NFPA To - PIEC 69b . ' 71c •-• 73aiiiiiEiiiiiV SPACE W/100A HDWR - i li-zi JUN 12 2019 75b 77c 79a SPACE W/100A HDWR ' : ' City City of Tukwila BUILDING DIVISION 81b . , 83c ' • - 85a SPACE W/100A HDWR ];iliiiii • 87b 89c Page 1 of 2 0 ELECTRICAL PANEL SCHEDULE 10/31/2018 76N.XLS SUB 96F1 Panel Designation 76N Location, bldg. Service Island 74/76 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer IEM SWITCHBOARD MAIN LUGS ONLY 1600A, 480V, 3PH, 3W 13 -YD -E310, 13 -YD -E311 D, E CASNE col. Date Installed 8/97 Feeder Size (4)4"C-(4)#750MCM per phase Fed From Northeast Substation #96F1 SHORT CKT. RTG., Isym 65k 39k AVAIL Revised Ckt 55, 57 59 Date Revised 10.31.18 Job Number W5581119 Breaker Type Ckt 2a 4b 6c Frame Trip SGLA 600A Wire Size Load Served Load Amos Ph A Ph B Ph C Cable No./Location 400A 3P (2)#4/0 400A RECEPT 320 #564 320 STALL 76 320 8a 101) 1 2c SGLA 600A 400A 3P (2)#4/0 400A RECEPT 320 #565 320 STALL 74 320 14a 16b 8c SFLA 250A 200A 3P # 4/0 200A RECEPT 160 #571 160 STALL 76 160 20a 22b 24c SPACE WITH 250A HARDWARE 26a 28b 30c 32a 34b 36c SELA 100A SELA 100A 100A 3P 100A 3P # 2 #2 100A RECEPT PANEL 7476R VIA 45 KVA TRANSFORMER 80 80 80 80 80 #574 STALL 76 #682 38a 40b 42c SELA 60A 60A 3P spare 44a 46b 48c SELA 30A 30A 3P spare 50a 52b 54c SELA 30A 30A 3P spare 56a 58b 60c SGLA 600A 400A 3P (2)#4/0 Feeds F/A-22 AIL/MFC (13-09 Bldg.) STALL 74 62a 64b 66c SPACE W/100A HDWR 68a 70b 72c 74a 76b 78c SPACE W/100A HDWR SPACE W/100A HDWR 80a 82b 84c SPACE W/100A HDWR 86a 88b 90c SPACE W/100A HDWR PHASE TOTAL AMPS TOTAL CONN LOAD Page 2 of 2 2394 2392 2394 1988 KVA °PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0460 DATE: 05/31/19 PROJECT NAME: BOEING #13-03 - YARD SITE ADDRESS: 10002 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: <SB Atvc Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/04/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 07/02/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire D Ping E.] PW 0 Staff Initials: 11/18/2013 SEQUOYAH ELECTRIC LLC Washington State Departrnent of k Labor & Industries tio;ne 1,,r,w601 Cnnl,ut Safety & Health Claims & Insurance Page 1 of 2 Farch L&I A-Zfmlex Help IVIV Workplace Rights Trades & Licensing SEQUOYAH ELECTRIC LLC Owner or tradesperson Principals Nichols, David E, PARTNER/MEMBER GHASSEMI, MAHMOOD, PARTNER/MEMBER Angeline, Scott R, PARTNER/MEMBER Jeffrey, Peter Casino, PARTNER/MEMBER Troceno, Rick, PARTNER/MEMBER Nagel, Cheryl L, PARTNER/MEMBER Nichols, Christopher R, PARTNER/MEMBER Doing business as SEQUOYAH ELECTRIC LLC WAUBINo 602 252 591 15135 NE 92ND ST REDMOND, WA 98052 425-814-6000 KING County Business type Limited Liability Company Governing persons DAVID E NICHOLS MAHMOOD GHASSEMI; Certifications & Endorsements License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no, SEQIJOEL977S9 Effective — expiration 01/2912003— 01/30/2021 Designated administrator Nichols, Christopher License type Electrical Administrator Bond HARTFORD CAS INS CO Bond account no. 52BSBAB5541 Active. Meets current requirements. License no. NICHOC`835RE $4,000.00 Received by L&I Effective date 01/29/2003 01/29/2003 Expiration date Help us improve TI)T-4/1"11C')1 )2,1 1n—QUrT Tr1rT Cl'77C09,Q A III— 411111n1