Loading...
HomeMy WebLinkAboutPermit EL19-0516 - TUKWILA FIRE STATION #51 - ELECTRICAL FOR NEW FIRE STATIONTUKWILA FIRE STATION 51 17951 SOUTHCENTER PKWY FINALED 08/11/2020 ELI 9-0516 Parcel No: Address: Cityof(;:iikwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206'431-3670 Inspection Request Line: 206-438'9350 Web site: http://mwvwx.Tukm||aVKA`Rmv ELECTRICAL PERMIT 3523049008 17951 SOUTHCENTER PK Y Project Name: TUKWILA FIRE STATION 51 Permit Number: EL19-0516 Issue Date: 11/15/2019 Permit Expires On: 5/13/2020 Owner: Name: CITY OF TUKWILA Address: 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KEN GOCHIS SO0S3RD AVE 5,SEATTLE, WA, 98134 MCKINSTRV CO LLC (ELECTRICAL) POBOX 24BG7,SEATTLE, WA, 98124 MCKINCL942DN ^'' Phone: (206) 471-9444 Phone: (206) 762-3311 Expiration Date: 3/15/2020 DESCRIPTION OF WORK: ELECTRICAL FOR NEW FIRE STATION 51 Valuation of single family: $0.00 Valuation of mf/comm: $1,240'000.00 Type ofWork: NEW Fees Collected: $15/404.37 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE Sewer District: NONE,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National ElectricaCode: WA Cities Electrical Code: WAC 296-46B: 2017WA State Energy Code: Date: 2017 2017 2015 |hearby certify that have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 am authorized to sign and obtain this development permit and agre10 e conditions attached to this permit. Signature:t4 Print Name: VAGNzkr— Date (( -1.----(q This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessibletotheBectrica| lnspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation ufthe provisions ofthe electrical code nrother ordinances cf the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUK Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Electrical Pennit No. E.. L 1ci -O5i(' Project No. Date Application Accepted: LP1g-i9 Date Application Expires: a - g. 1cj (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 11615k Site Address: 4-1 Southcenter Parkway Suite Number: Floor: King Co Assessor's Tax No.: Tenant Name: Tukwila Fire hall#51 PROPERTY OWNER Company Name: McKinstry LLC Name: City Of Tukwila Name: Ken Gochis Address: 6200 Southcenter BLV Contr Reg No.: 602569922 Exp Date: 12/31/20: City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Company Name: McKinstry LLC Address: 5005 3rd Name: Ken Gochis Phone: 206-762-3311 Fax: Contr Reg No.: 602569922 Exp Date: 12/31/20: Address: 5005 #rd Ave South City: S e at t 1 e State: WA Zip: 9 8 1 3 4 phone:206-471-9444 Fax: Email: keng@Mckinstry . com New Tenant: Ej Yes D ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: McKinstry LLC Address: 5005 3rd City: Seattle State: WA Zip: 98134 Phone: 206-762-3311 Fax: Contr Reg No.: 602569922 Exp Date: 12/31/20: Tukwila Business License No.; BUS —0994320 Valuation of Project (contractor's bid price): $ 1,240,000.00 Scope of Work (please provide detailed information): Electrical for new Firehall Will service be altered? ID Yes El No Adding more than 50 amps? ED Yes LJ No Type of Use: Commercial Type of work: a New 0 Addition 0 Service Change 0 Low Voltage 0 Generator 0 Fire Alarm Property Served by: a Puget Sound Energy 0 Seattle City Light WAPermit Center \ Applications-HandoutsTermit Applications \ PDFAElectrical Permit Application Revised 7- I 9.doex O Remodel 0 Tenant Improvement o Telecommunication 0 Temporary Service Pqrrolrlf, RESIDENTIAL NEW RESIDENTIAL SERVICE 0 New single family dwellings $180.00 (including an attached garage) O Garages, pools, spas and outbuildings $120.00 ea O Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES O Service change or alteration $120.00 (no added/altered circuits) • Service change with added/altered circuits $100.00 number of added circuits $10.00 ea O Circuits added/altered without service change $60.00 (up to 5 circuits) O Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea O Meter/mast repair ..... ................. ... . .. $80.00 O Low voltage systems $60.00 (alami, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $60.00 ID Temporary service (generator) $90.00 O Manufactured/mobile home service $100.00 (excluding garage or outbuilding) O Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules, Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 6/13/2019 Print Name: Ken GOchis Day Telephone: 206-471-9444 Mailing Address: 5005 3Rd Ave South Seattle WA 98134 City WAPermit Center\ Applications-Randouts \Permit Applications PIWAElectrical Permit Application Revised I-17-19.doex State Zip DESCRIPTIONS ACCOUNT QUANTITY PAID $65.00 $65.00 $65.00 $65.00 $65.00 PermitTRAK EL19-0516 Address: 17951 SOUTHCENTER PKWY Apn: 3523049008 TECHNOLOGY FEE TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R19087 8000.322.900.04.00 0.00 Date Paid: Friday, November 15, 2019 Paid By: CITY OF TUKWILA Pay Method: ACCOUNT 90830402.1000.107 AN Printed: Friday. November 15. 2019 12:11 PM 1 of 1 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS I ACCOUNT 1 QUANTITY PAID PermitTRAK $15,339.37 EL19-0516 Address: 17951 SOUTHCENTER PKWY Apn: 3523049008 $15,339.37 ELECTRICAL $14,811.89 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $11,849.51 PLAN CHECK FEE R000.345.832.00.00 0.00 $2,962.38 TECHNOLOGY FEE $527.48 TECHNOLOGY FEE 1 R000.322.900.04.00 0.00 $527.48 TOTAL FEES PAID BY RECEIPT: R17915 $15,339.37 Date Paid: Tuesday, June 18, 2019 Paid By: MCKINSTRY CO, LLC Pay Method: CHECK 10297384 Printed: Tuesday, June 18, 2019 10:02 AM 1 of 1 c SYSTEMS 11/1/2019 City of Tukwila Department of Community Development KEN GOCHIS 5005 3RD AVE S SEATTLE, WA 98134 RE: Permit Application No. EL19-0516 TUKWILA FIRE STATION 51 17951 SOUTHCENTER PKWY Dear KEN GOCHIS, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 6/18/2019, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of COMMENTS OUT and is due to expire on 12/18/2019. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL19-0516 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 July 18, 2019 City of Tukwila Department of Community Development KEN GOCHIS 5005 3RD AVE S SEATTLE, WA 98134 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL19-0516 TUKWILA FIRE STATION 51 - 17951 SOUTHCENTER PKWY Dear KEN GOCHIS, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. -SHEET E100 1). SPECIFY Cu CONDUCTORS FOR SERVICE AND FEEDERS. 2). ATS -MDP TO BE RATED 1000 AMP, NOT 800. 3). GENERATOR AND PORTABLE GENERATOR TO HAVE CAPACITY TO SUPPORT THE LOAD. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. To better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at . Sincerely, K:ndace Nichols Permit Technician File No. ELI9-0516 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 °PEW COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0516 DATE: 10/21/2019 PROJECT NAME: TUKWILA FIRE STATION 51 SITE ADDRESS: 17951 SOUTHCENTER PKWY Original Plan Submittal X Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENT: 1W2 K\ Fire Prevention Public Works Structural n Planning Division Permit Coordinator II PRELIMINARY REVIEW: Not Applicable (no approval/review required) DAIE: 10/22/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/19/2019 Approved Corrections Required Approved with Conditions r Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fi • 0 Ping 0 PW 0 Staff Initials: 12/18/2013 EMT COORD GOP? PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0516 PROJECT NAME: TUKWILA FIRE STATION 51 SITE ADDRESS: 17951 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Lette DATE: 06/18/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: CA) ite Building Division Public Works Fire Prevention Structural Planning Division r Permit Coordinator • PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 06/20/19 Structural Review Required DATE: ri APPROVALS OR CORRECTIONS: Approved P Corrections Required (corrections entered in Reviews) DUE DATE: 07/18/19 Approved with Conditions Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Ping D PW Staff In itials: 12/18/2013 eft, City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc Date: 70/2//Z4/ Plan Check/Permit Number: ELL9 Lo Response to Incomplete Letter # 51 Response to Correction Letter # j. Revision 1 before Permit is Issued O Revision # after Permit is Issued j Revision requested by a City Building Inspector or Plans Examiner O Deferred Submittal # Project Name: ---7?--11(-4)//9 FiCse. //I Project Address: 79/0- ,J;),..,,LA ,4 AA/a,' ;/L—:,—kr/,4 c8/8'8' Phone Number: ade • 7/f./vs--,) Contact Person: /4 a•ai. Sire, Summary of Revision: (7.46,- 1-0— JilAA.1 Aiks-/44--1 Sheet Number(s): "Cloud" or highlight all areas of revision including date ofrevision Received at the City of Tukwila Permit Center by: O Entered in TRAKiT on /o-24—/' CAUserakKaridace-MAppData‘LocaRMicrosoft \ Windows \ThietCache'Content.Outlook Q851.8YWORevision Submittal Form.doc Revised: August 2019 CWxhinglay 5. Dep.... IF Labor & Industries (https://lni.wa.gOv) Contractors MCKINSTRY CO LLC Owner or tradesperson Principals ALLEN, DEAN CHARLES, PARTNER/MEMBER Hagar, Joseph D, PARTNER/MEMBER Casey, Joy D, AGENT MOORE, DOUGLAS J, PARTNER/MEMBER (End: 03/09/2018) ALLEN, DAVID, PARTNER/MEMBER (End: 03/09/2018) TEPLICKY, JOSEPH W (BILL), PARTNER/MEMBER (End: 03/09/2018) BLACK, STEPHEN, AGENT (End: 03/09/2018) Doing business as MCKINSTRY CO LLC WA UBI No. 602 569 922 PO BOX 24567 SEATTLE, WA 98124 206-762-3311 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active Meets current requirements. License specialties GENERAL License no. MCKINCL942DN Effective — expiration 03/15/2006— 03/15/2020 Designated administrator Gochis, Kenneth License type Electrical Administrator Bond Western Surety Co Bond account no. 929523050 Active Meets current requirements. License no. GOCHIK*841 DU $4,000.00 Received by L&I Effective date 02/25/2011 03/06/2011 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Infraction no. EALRD00504 Issue date Satisfied RCW/WAC LIGHTING FIXTURE SCHEDULE TYPE LAMPS MANUFACTURER DESCRIPTION B-I G-I G-2 P-I P-2 PL-I LED 3W 3000K BEGA LEDGE 6081-030-900- SP-9-9075- TRN-SS NOT USED LED HUBBELL 21W BUL-IL4K-U SERIES 4000W LED 242W 4000K NOT USED. LED 72W 4000K FC LIGHTING FCFII05 SERIES LSI INDUSTRIES MIRADA XALM-FT-UE-ALSC- PCR/7P-PCI20-IL WITH AIR -LINK WIRELESS CONTROL SYSTEM. WITH LUMEWAVE SERIES WIRELESS ETHERNET GATEWAY ECHELON 100140 SERIES. LEOTEK LIGHTING AR-I830M2 SERIES ECHELON TOP900 AND PRUDENTIAL P46-LED4-HO-8-SAL- DI/CW-UNV PINNACLE EX3DI SERIES BOLLARD FIXTURE 23"H X 3.5"W X 2.2"THICK RECTANGULAR ALUMINUM HOUSING. UL LISTED FOR WET LOCATION. NOT USED. GROUND LIGHTING RATING. MOUNTING LIGHTING FIXTURE SCHEDULE TYPE LAMPS MANUFACTURER DESCRIPTION RL-3 RL-4 MOUNTED LANDSCAPE RL-5 LED FIXTURE. IP 65 PROVIDE WEATHERPROOF JUNCTION BOX. SINGLE HEAD SQUARE PARKING POLE RL-6 FIXTURE WITH TYPE FT DISTRIBUTION AND FULL CUTOFF OPTICS. RATED AT 27,000 LUMENS WITH EFFICACY OF 116 LUMENS PER WATTS. PROVIDE WITH INTEGRATED WIRELESS CONTROL AND INTEGRATED RL-6E PHOTOCELL SENSOR. UL WET LABEL, -20F DRIVER, IP66. PROVIDE 23- FOOT HIGH 5 INCH SQUARE ALUMINUM POLE. PROVIDE UTILITY RL-7 VAULT #24R-B-LB PRECAST POLE BASE WITH 24" ABOVE GRADE. NOT USED. PENDANT MOUNTED 4"x 8 DIRECT/INDIRECT LED FIXTURE WITH LENS RATED AT 14000 LUMENS. PROVIDE WITH 0-IOV DIMMING DRIVER. PI-IE LED SIMILAR TO PL-I EXCEPT WITH 72W INTEGRAL EMERGENCY BATTERY 4000K PACK. PL-2 PL-3 PL-4 LED 13W 4000K LED 30W LED 34.5W 4000K PL-4E LED 34.5W 4000K PL-5 LED 37.2W 4000K PL-5E LED 37,2W 4000K PL-6 NOT USED. PL-7 LED 65W 3500K RL-I RL-2 NOT USED LED 11.8W 3500K LUMENPULSE LACYN SERIES HK LIGHTING CZXL201 SERIES LITHONIA SB-40L SERIES METALUX 4WNLED SERIES PRUDENTIAL P46-LED4-SO-4-SAL- DI/CW-UNV PINNACLE EX4B SERIES PRUDENTIAL PRUI5-LED4-SO-4-D3- UNV-CA48 PINNACLE L8DI SERIES LITHONIA FEM SERIES GOTHAM EVO SERIES PORFOLIO LD6B SERIES CABLE HUNG 2.75" DIAMETER X 13" LONG ROUND DECORATIVE PENDANT WITH SUSPENDED DECO TIER LENS. PROVIDE 0-I0V DIMMING DRIVER. SIMILAR TO FIXTURE SL-I EXCEPT CHAIN HUNG. PENDANT MOUNTED 4"x 48" DIRECT/INDIRECT LED FIXTURE WITH LENS, PROVIDE WITH 0-I0V DIMMING DRIVER. SIMILAR TO PL-4 EXCEPT WITH INTEGRAL EMERGENCY BATTERY PACK CABLE HUNG LINEAR 4-FOOT LED WITH DIRECT/INDIRECT DISTRIBUTION. RATED AT 1300 LUMENS PER FOOT. PROVIDE WITH 0-I0V DIMMING DRIVER SIMILAR TO PL-5 EXCEPT WITH INTEGRAL EMERGENCY BATTERY PACK. NOT USED. PENDANT MOUNTED 8" X 8' LED FULLY GASKETTED FIXTURE. NOT USED. 6 INCH ROUND RECESSED LED DOWNLIGHT WITH INTEGRAL POLYCARBONATE LENS. SPECULAR CLEAR ALZAK REFLECTOR. RL-2E LED SIMILAR TO RL-2 EXCEPT WITH II.8W INTEGRAL EMERGENCY BATTERY 3500K PACK. CT ENCLOSURE AND METER PER PSE REQUIREMENTS NEMA 3R TO PSE TRANSFORMER (SEE SITE PLAN) (3)4"-4#600AL & GENERATOR SET 230 KW 208Y/120V,30,4W 1.25'C RL-8 RL-9 RL-10 SL-I SL-IE SL2-8 LED 14.3W NOT USED LED II.8W 4000K LED 14W 4000K LED 14W 4000K LED 28W 4000K LED 23.5W 4000K LED 3.5W 3500K NOT USED. LED 39W LED 39W LED 25.6W 3000K SL2-I2 LED 38.4W 3000K SL2-I6 LED 5I,2W 3000K SL-3 SL-4 SL-5 SL-6 GOTHAM EV030-I5-6-120 KIRLIN LIGHTING LRR-05 SERIES GOTHAM EVO-LW PORFOLIO 6LBSW SERIES FINELITE HP-4R-2-V-840 NEO-RAY SI24DR-S SERIES FINELITE HP-2R-4-V-840 NEO-RAY SI22DR-S SERIES GOTHAM EVO-SQ-40-20 PORFOLIO LDSQ4B20D010 SERIES WAC LIGHTING HR-LED-232R SERIES LITHONIA SB-40L SERIES METALUX 4VT3-LD5 SERIES LUMINII KSW-8-30K-SO SERIES LUMINI I KSW-I2-30K-SO SERIES LUMINI I KSW-I6-30K-SO SERIES LED WAC LIGHTING 3.5W LED-T024 SERIES PER FOOT NOT USED LED 31W 4000K LED 105W 4000K SL-6A LED 105W 4000K A PORTABLE GENERATOR QUICK CONNECTOR BOX WITH INTEGRAL DISCONNECT 800A, 208Y, 120V, 30, 4W NEMA 3R (2)4"-4#750AL & 1#1/OCU GND AUTO TRANSFER SWITCH (ATS-MDP) 1000A,4-POLE 65K AIC SERVICE ENTRANCE RATED tnt $o0A oc,PP (3)4"-4#600AL & QS( 25-0 At A 3otttl s,ot 6o4bit M 54.11ek 111 LT EaCL•SJAk PM ZSo. IOL (b)[r)•-(2) 1.25" WITH CONTROL WIRING 800/3 n 1000/9 • (2)4"-4#750AL & 1#1/OCU GND - TO ANNUNCIATOR PANEL. PROVIDE REQUIRED WIRING LITHONIA FEM LOW PROFILE SERIES WINONA WSL=105W-LSLMSL4- AOOADJ-IO0DEG- LLP4A-SGB WINONA WSL=I05W-LSLMSL4- I00FMC-I00DEG- LLP4A-SGB RECESSED SHOWER LIGHT, 6" DOWNLIGHT WITH DROPPED LENS. UL LISTED FOR WET LOCATION. NOT USED. RECESSED WALL WASHER DOWNLIGHT WITH LENS. 3000 RATED LUMENS RECESSED 4" X 24" LED FIXTURE WITH LENS, PROVIDE REQUIRED RECESSED MOUNTING TRIMS. 0-I0V DIMMING DRIVER. SIMILAR TO RL-6 EXCEPT WITH REMOTE EMERGENCY BATTERY PACK. RECESSED 2" X 48" LED FIXTURE WITH LENS. PROVIDE REQUIRED RECESSED MOUNTING TRIMS. 0-I0V DIMMING DRIVER. RECESSED DOWNLIGHT PROVIDE MOUNTING DRIVER. 4" SQUARE LED FIXTURE WITH LENS. REQUIRED RECESSED TRIMS. 0-10V DIMMING RECESSED ADJUSTABLE DOWNLIGHT, I" APERTURE. NOT USED. I'X4' LENSED SURFACE MOUNT WRAPAROUND FIXTURE SIMILAR TO SL-I EXCEPT WITH EMERGENCY BATTERY PACK. EXTERIOR BENCH MOUNTED 8' FIXTURE WITH LENS. UL LISTED FOR WET LOCATION. COORDINATE LOCATION WITH LANDSCAPE ARCHITECT. EXTERIOR BENCH MOUNTED 12' FIXTURE WITH LENS. UL LISTED FOR WET LOCATION. COORDINATE LOCATION WITH LANDSCAPE ARCHITECT. EXTERIOR BENCH MOUNTED 16' FIXTURE WITH LENS. UL LISTED FOR WET LOCATION. COORDINATE LOCATION WITH LANDSCAPE ARCHITECT. FLEXIBLE SILICON TAPE LIGHT. INSTALL AT THE BACKSIDE OF NUMBER SIGN. PROVIDE LEQUIRED LENGTH TO BE ADEQUATE FOR THE ENTIRE BACKSIDE OF SIDE. PROVIDE REQUIRED QUANTITY OF REMOTE POWER SUPPLY DRIVER. NOT USED. SURFACE CEILING MOUNTED 8" X 48" FIXTURE, FULLY GASKETTED WITH LENS. 0-IOV DIMMING DRVER. UL LISTED FOR WET LOCATION. PROVIDE WITH INTEGRAL OCCUPANCY SENSOR. SURFACE MOUNTED FIXTURE. UL LISTED FOR WET LOCATION. PROVIDE 0-IOV DIMMING DRIVER. PROVIDE REMOTE 120V POWER TRANSFORMER SURFACE MOUNTED FIXTURE. UL LISTED FOR WET LOCATION. PROVIDE 0-I0V DIMMING DRIVER• PROVIDE REMOTE I20V POWER TRANSFORMER FUTURE PV DISCONNECT AND PRODUCTION METER MAIN DISTRIBUTION PANEL (MDP) 1000A, 208/120V,30,4W 65K AIC 3 #6D0AL & (3 "4#600AL&' �- 1'i(r U GND 1 !0 U GND A I /X MANUAL TRANSFER{ /J`\ SWITCH 1 1000A / p GtJ 270 Lt., Hlo AL N(o kw 1.25" WITH CONTROL WIRING NOTE: ALL SERVICE AND DISTRIBUTION FEEDERS ARE ALUMINUM WITH COPPER GROUND CONDUCTORS UNLESS OTHERWISE NOTED. III 1000/3 100/3 (SPARE) 225/3 ISPOl (SPARE) 2.5"-4#250AL & 1#4CU GND 2.5"-4#250AL & 2" CONDUIT STUB ON ROOF FOR FUTURE PV SYSTEM WIRING 1"-4#10CU & 1#10CU GND 225/3 n 400/3 r\ 200/3 1#4CU GND 5"-4#250AL & U GND rF 3 co GROUND PER NEC PANEL A PANEL B PANEL M \\---RHRV 2.5"-4#250AL & 1#4CU GND LIGHTING FIXTURE SCHEDULE TYPE LAMPS MANUFACTURER DESCRIPTION UC WL-I WL-2 WL-3 LED 20W LED 20.5W 3500K LED 9W LED 40W 4000K WL-4 LED 55W WL-4A LED 18W 4000K WL-5 WL-6 WL-7 X X2 LED 13W 3000K LED 38W LED 8.4W LED IW LED IW KELVIX SCH409 SERIES WAC LIGHTING DWELLED WS-77624-35-AL WAC LIGHTING BL- I 630-WT EDGE LIGHTING NIGHT3-WH A -LIGHT NI-8-LH-40-U-A24-D SERIES SPI LIGHTING EIWI1906 SERIES PHILIPS GARDCO 101-55LA-PCB-120V PHILIPS GARDCO II IL-I6L-350-MN-G2- PCB SERIES CGF DESIGN AM-9-FT SERIES BEGA LIGHTING 33581-120 PERFORMANCE LIGHTING ALU WALL/S SERIES A -LIGHT A4-M48-LH-35-U-D BIRCHWOOD NOL-LED 125-SLO-35- 3-FW PHILIPS 45V SERIES EMERGILITE WLSNX SERIES LENGTH AS NEEDED TO ALIGN WITH UNDERCABINET WITH LENS COORDINATE WITH ARCHITECT. CONTROLLED BY WALL SWITCH AND AREA OCCUPANCY SENSOR, PROVIDE WITH REMOTE POWER SUPPLY DRIVER. 24" LONG VANITY LIGHT. WALL MOUNTED READING LIGHT WITH INTEGRAL SWITCH AND ADJUSTABLE ARM WALL CANTILEVER MOUNTED 8-FOOT LINEAR DIRECTIONAL LED FIXTURE. PROVIDE WITH 0-IOV DIMMING DRIVER. TRAPEZOIDAL SCONCE. DISTRIBUTION. OPTICS. UL LOCATION. WEDGE LED WALL FORWARD THROW FULL CUTOFF LISTED FOR WET MINI -TRAPEZOIDAL WEDGE SCONCE. FORWARD DISTRIBUTION. FULL OPTICS. UL LISTED LOCATION LED WALL THROW CUTOFF FOR WET WALL MOUNTED LIGHT FIXTURE. UL LISTED FOR WET LOCATION. WALL MOUNTED DIRECT/INDIRECT 48" LED FIXTURE. PROVIDE WITH WALL MOUNTING ACCESSORIES. VANITY LIGHT FIXTURE. MOUNTED ON THE SIDE OF MIRROR. CEILING/WALL MOUNT EDGE LIT LED EXIT SIGN WITH BATTERIES, SELF DIAGNOSTICS AND ALL MOUNTING ACCESSORIES REQUIRED. PROVIDE ARROWS AND FACES AS SHOWN ON DRAWINGS. PROVIDE WHITE BODY WITH GREEN LETTERS AND UNIFORM LENS OVER LED. SIMILAR TO FIXTURE X EXCEPT DOUBLE FACE. ALL COLORS, FINISHES, ETC. ARE BY ARCHITECT FROM MANUFACTURER'S STANDARD COLOR OPTIONS 01 o® O) 10E 4 O' • De -ID El+ OS os PC ter U U at en w wp AN AC Wjle WAP D @0 C) 0 ® 4 5 y� 0 ❑F D® OR OD SD® Q FS a AV 1,11 f=-C LEGEND CONDUIT CONCEALED IN CEILING OR WALLS CONDUIT CONCEALED UNDERGROUND OR UNDER FLOOR 3/4" CONDUIT. TICK MARKS INDICATE NUMBER OF #12 WIRES. NO TICK MARKS EQUALS 2#12. GROUND WIRE NOT SHOWN. PROVIDE GROUND WIRE IN ALL 120V AND ABOVE CIRCUITS. HOME RUN TO DESTINATION INDICATED. 1" MINIMUM UNLESS NOTED OTHERWISE. RECESSED LIGHT FIXTURE, LETTERS DENOTE SWITCHING SURFACE OR PENDANT MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE SURFACE OR PENDANT LIGHT FIXTURE WALL MOUNTED FIXTURE FIXTURE WITH EMERGENCY BATTERY PACK POLE TOP LIGHT FIXTURE/STREET LIGHT FIXTURE POLE LIGHT EXIT SIGN LIGHT FIXTURE TYPE X, EXCEPT AS NOTED WALL SWITCH, 1-POLE (SWITCH LEG INDICATED WHERE REQUIRED) WALL SWITCH, 3-WAY WALL SWITCH WITH INTEGRAL VACANCY SENSOR LOW VOLTAGE SWITCH , 1-POLE VACANCY SENSOR PHOTO CELL LIGHTING FIXTURE TYPE DESIGNATOR, SEE LIGHT FIXTURE SCHEDULE DUPLEX RECEPTACLE CONTROLLED DUPLEX RECEPTACLE. CONTROLLED BY ROOM/AREA OCCUPANCY SENSOR. DUPLEX RECEPTACLE WITH USB PORT DUPLEX RECEPTACLE WITH USB PORT DUPLEX RECEPTACLE ABOVE COUNTER DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE GFI TYPE WEATHERPROOF DUPLEX RECEPTACLE (GFI TYPE) FLUSH FLOOR BOX OUTLET WITH DEVICES AS SHOWN 10 SPECIAL RECEPTACLE AS NOTED DRYER OUTLET, NEMA 14-30R RANGE OUTLET, NEMA 14-50R HOOD OUTLET, CONNECT ALL LIGHTS MOTORIZED CONTROLLER PUSHBUTTON SWITCH ADA DOOR ACTUATOR EQUIPMENT CONNECTION MOTOR CONNECTION DISCONNECT SWITCH FUSED DISCONNECT SWITCH MANUAL MOTOR STARTER COMBINATION STARTER JUNCTION BOX FIRE ALARM PULL STATION FIRE ALARM HORN WITH ADA STROBE FIRE ALARM ADA STROBE WALL MOUNTED FIRE ALARM ADA STROBE SMOKE DETECTOR RESIDENTIAL COMBINATION SMOKE ALARM/CO DETECTOR, 120V WITH BATTERY BACK-UP DUCT SMOKE DETECTOR HEAT DETECTOR SMOKE DAMPER CONVECTION SPRINKLER CONNECTION TAMPER SWITCH ALARM CONNECTION FLOW SWITCH ALARM CONNECTION ALARM SWITCH CONNECTION AV SYSTEM ANALOG CLOCK, 12" ROUND ALERTING MESSAGE SIGN SPEAKER - WALL MOUNT SPEAKER - PENDANT CEILING MOUNT FLUSH CEILING SPEAKER WITH LED LIGHT le- TELEVISION OUTLET. PROVIDE 2-1/8" DEEP DOUBLE GANG BOX WITH SINGLE GANG MUDRING, BLANK FACEPLATE AND 1" CONDUIT TO ABOVE ACCESSIBLE CEILING. WALL PHONE SINGLE PORT OUTLET. PROVIDE 2-1/8" DEEP DOUBLE GANG BOX WITH SINGLE GANG MUDRING, BLANK FACEPLATE AND 1" CONDUIT TO ABOVE ACCESSIBLE CEILINGS. SINGLE PORT DATA OUTLET (NUMBER=NUMBER OF RJ45 JACKS). PROVIDE 2-1/8" DEEP DOUBLE GANG BOX WITH SINGLE GANG MUDRING, BLANK FACEPLATE AND 1" CONDUIT TO ABOVE ACCESSIBLE CEILING. WIRELESS ACCESS POINT SINGLE PORT DATA OUTLET. PROVIDE 2-1/8" DEEP DOUBLE GANG BOX WITH SINGLE GANG MUDRING, BLANK FACEPLATE AND 1" CONDUIT ABOVE ACCESSIBLE CEILING. B DATA AND VOICE OUTLET. PROVIDE 2-1/8" DEEP DOUBLE GANG BOX WITH SINGLE GANG MUDRING, BLANK FACEPLATE AND 1" CONDUIT TO ABOVE ACCESSIBLE CEILING. RE% 0 REQUEST TO EXIT CARD READER ELECTRIC LOCK CCTV CAMERA METER BASE 208V OR 240V PANEL LVR 480V PANEL TRANSFORMER GFI GROUND FAULT CIRCUIT INTERRUPTER wo AL - T CCTV WEATHERPROOF RADIO ANTENNA CIRCUITRY IN RACEWAY, 2" MINIMUM ACCESS CONTROL CIRCUIT AS REQUIRED BY MANUFACTURER. PROVIDE IN RACEWAY IN WALLS AND ABOVE NON ACCESSIBLE CEILINGS. ALERTING SYSTEM CIRCUITRY IN RACEWAY, 3/4" MINIMUM. TELEPHONE/DATA RACEWAY, 1" MINIMUM WITH PULLWIRE CLOSE CIRCUIT TELEVISION CIRCUIT AS REQUIRED BY MANUFACTURER. PROVIDE IN RACEWAY IN WALLS AND ABOVE NON -ACCESSIBLE CEILINGS. FA FIRE ALARM SYSTEM CIRCUITRY AS REQUIRED BY MANUFACTURER INSTALLED IN METALLIC RACEWAY LV TV LOW VOLTAGE CIRCUITRY AS REQUIRED BY MANUFACTURER IN RACEWAY WHERE IN WALLS, ABOVE NON -ACCESSIBLE CEILINGS OR EXPOSED. TV CIRCUIT, PROVIDE IN RACEWAY IN WALLS AND ABOVE NON -ACCESSIBLE CEILINGS FLAG NOTE SEPARATE PERMIT RE UIRED FOR: ad Mechanical Cif Electrical Plumbing a Gas Piping City of Tukwila BUILDING DIVISION I L�. F:'A..E COPY EL-I�1- b91b Permit N•i. '' ..: ....: .,, ea:c ,,..... c. ., ... iT`�r CORRECTION LTR# I CITY GP Tt.KVIL OCT 212019 PER:bliT TRAVIS a ASSOCIATES !M9We4MeA,AN Swe Sre n anae ma ITZMAURICE WA 99:J9 120-.95-72S4 32 10117/19 ASI-007 3 4/5/19 Addendum 9 1B 12111/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 443 1218 www.weinsteinau.com C 2018 Weinstein A+U - These documents have been prepared specifically for the above named project. They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. REVIMED >.011 ji COMPLIANCE 'MTrr NFPA 70 - ?NEC NOV 142019 JB gc-- City of Tukwila BUILDING DIVISION JURISDICTIONAL APPROVAL STAMP Issue Date REVISED BID SET 1/17/19 ARCHITECTS + URBAN DESIGNERS D Z LLJ I VI Z ONE LINE DIAGRAM NTS DETAIL INDICATOR WITH SHEET WHERE DRAWN INDICATED EL19-0516 EUCla0514 Sheet Title ONE LINE DIAGRAM, LIGHTING FIXTURE SCHEDULE, LEGEND Sheet E100 1 • C o5 / l I l/ f i MOTORIZED GATE jt GATE UPS CHARGER I z .---'] B- i"-3#8 56 8& & 1#12 GND B-64,66 1"-3#8 & 1#12 GND GROUND LOOP SENSOR (TYP) `' ITEL/INTERNET/FIBER OPTIC/CATV UTILITY SERVICE DEMARC COMMUNICATION BOARD 1" C TO TRAFFIC SIGNAI LLER FLAG POLE LIG TOFACP- \ \ FA POST INDICATOR I VALVE (PIV) f SL2-12 7 A-3 VIA LVR 1" 2#8 & 1#2 GND COMMUNICATION LINES (1)4" PVC (TEL) (2)4" PVC (INTERNET/FIBER OPTIC) (1)4" PVC (CATV) (1)4" PVC (SPARE) A-7 VIA LVR 1"- 2#10 & 1#12 GND FLUSH ON GRADE d B-1 5 V CT ENCLOSURE AND UTILITY METER ATS-MDP- PANEL MDP —.\`a aE MTS-MDP—. iti A-5 VIA LVR—' 1"- 2#10 & 1#12 GND B-1 5 CABLE TV VAULT 2' X 4' _ (VERIFY AND COORDINATE WITH SERVICE PROVIDER) EXISTING TELEPHONE AND FIBER OPTIC VAULT (VERIFY IN FIELD) EXISTING COMCAST VAULT / iv(VERIFY LOCATION IN FIELD) FUTURE PV,, SYSTEM DISCONNECT AND PRODUCTION METER TRANSFORMER PAD WITH VAULT B-1 B-5Q52� hI 1"C, STUB AT ELEC. ROOM PANEL B" FUTURE DUAL 1 -ELECTRIC VEHICLE !! CHARBjNG'STATION J A-1 VIA LVR-- 1"- 2#8 & 1#12 GND -1 1"C, STUB AT ELEC. ROOM P ELB A-1 VIA LVR 1"- 2#� & 1#12 GND "N FUTURE DUAL ELECTRIC VEHICLE CHARGING STATION GENERATOR BLOCK/COOLANT HEATER P-1 A-311 FIRE STROBE 2000 CONTROLLER J.BOX PHOTODIODE ASSEMBLY 1" 2#18 & 1#14 GND TO GATE CONTROLLER NG GATE GATE UPS CHARGER B-60,62 GRCUND LOOP. SENSOR (TYP) _. -- (2)4" PVC PSE ELECTRIC SERVICE CONNECTION APPROXIMATE: 300' - - e N i - E EXISTING CENTURY LINK FIBER OPTIC AND COPPER LINES - - SITE PLAN - ELECTRICAL SCALE 1/16" =1'-0" ELi 9-0516 GENERAL NOTES: 1. ALL WORKS RELATED TO UTILITY POWER SERVICE CHALL MEET THE REQUIREMENTS AND STANDARDS OF PUGET SOUND ENERGY (PSE) UTILITY PRIOR TO ROUGH -IN. 2. ALL WORKS RELATED TO TELEPHONE, INTERNET AND CABLE TELEVISION SERVICES SHALL MEET THE REQUIREMENTS OF SERVICE PROVIDERS. COORDINATE WORK PRIOR TO ROUGH -IN. 3. VERIFY WITH UTILITY SERVICES COMPANIES FOR EXACT LOCATIONS OF THEIR RESPECTIVE SERVICE POINT OF CONNECTION PRIOR TO ROUGH -INS. FLAG NOTES: COORDINATE FINAL LOCATION OF UTILITY SERVICE CONNECTION POINT WITH RESPECTIVE UTILITIES. FUTURE ELECTRIC VEHICLE CHARGING STATION. PROVIDE CONDUIT INFRASTRUCTURE ONLY TERMINATE AT ELECTRICAL ROOM. POWER CONNECTION TO LED BACK LIT SIGNAGE LETTER. PROVIDE CONNECTION PER SIGNAGE LETTER. TYPICAL FOR 20 LETTERS. ENTRY GATE SECURITY KEY PAD MOUNTED ON PEDESTAL. POWER TRANSFORMER J. BOX FOR FLAG POLE LIGHT. OPTICOM TRAFFIC CONTROL PUSH BUTTON MOUNTED ON PEDESTAL. SEE DETAIL 3/E701. COORDINATE FINAL LOCATION WITH ARCHITECT. MANUAL PUSH BUTTON MOUNTED ON PEDESTAL FOR GATE CONTROL TO VEHICLE EXIT. WEATHERPROOF J.BOX TO HOUSE LIGHT FIXTURE REMOTE DRIVER. MOUNT ON UNDERSIDE OF BENCH. COORDINATE FINAL LOCATION WITH LANDSCAPE ARCHITECT. PHOTO -EYE SAFETY SENSOR. PROVIDE CONTROL WIRING TO GATE CONTROLLER. PHOTODIODE ASSEMBLY MOUNTED AT PARKING POLE LIGHTS AT +8'6" ABOVE GROUND. PROVIDE REQUIRED MOUNTING BRACKET. FIRE STROBE 2000 CONTROLLER J.BOX. SEE DETAIL 4/E701. MAINTAIN 12" SEPARATION BETWEEN POWER LINE AND GAS LINE DUCT WORK • FITZMAURICE & ASSOCIATES I200 WMgk• An. 11_ Sub V Sane ,WA 99109 p 286-285.7228 1206285.1294 3 4/5/19 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com C 2018 Weinstein A+U - These documents have been prepared specifically for Ole above named project. They am not salable for use on other projects or in other locations without he approval and participation of the Architect. R)=VIEi�VF_�- FOR COMPLIANCE WITH1 NFPA 70 - NEC i I N3I 1 •< 2D19 City or Tukwila BUILDING DIVISION • JURISDICTIONAL APPROVAL STAMP Issue Date Sheet Title Sheet REVISED BID SET 1/17/19 SITE PLAN • ELECTRICAL E101 ARCHITECTS + URBAN DESIGNERS D Z W I z W 3 / L WL De A-9 OR PL 3 PL 3 21 21 CORRIDIA ®X RL-2E135 RL_y ®X 21 21 21 21 $ CLEAFY PL-S RL-2 1 121 ...Y. 2106 I SC 137 (21 UC - 21 up X® 21 PL-3 21 PL-3 21 WL5 , 21 akuji CORRIDOR V A2t RL-201 ® RL-2 X 21 21 21 PL 3 21 co MECH 133 PL-3 21 WL-4 A-9 APP BAY +sq.' WL-4 A9 SL-1 19 SL-1 19 RL-2E® -2 A1tWW SH Jo 1128 to SL- 19 19 b PL-3 19 oaf AIRLOCK 1J �RL(ORL.2 15 15 PL-3 19 EAR rnP I 1._.-_... PL-3 129 PL-3 M 19 19 i I PL-3 PL-3 19 ® 19 PL-3 PL-3 19 19 O RL-6 as 15 LAJAN\ coe fO RL- 19 -L " II eAII1MCI� RL-2E109 R- _2 15 15 n SL3 * SL-3 A A-11 VIA LVR 1"- 2#10 & 1#12 GND G ;\ /' �. c' - bt-4 A-9 WL A-9 1 QRL. ATH •L ) 19 WL 19 RL-3 E� �DA ®T R1163 )1814 !Rile 2S PL-5 PL-5 PL-5E 3 STAT7 OFFIC1 7 Os • I� 2 9 ] BATH , RL-3 A-19 it14 19 19 RL-5 RL-5 815 815 CORRID }119. RL-6E $ 16 I RL-6E 15 os RL-6 15 a CORR 110 I 1 18A RL-6 5 tl BUNK 116 Q RL-2 17 Luigi I 116 RL-6 15 B OL-2 ikian VVL-2 17) • 2 17i, R�3E 1124 CAP,@RL-2 �� RL-617 ._ VA • -2 L17 •�� FFB�II p., S A-17 L-2ERInkD v C RL-2Er 5 L__55 �X2 RL-5 5 L� VIAS 3a7 nrr os RL-7 1 15 LVR PL-2 13a G-2 3 G-2 3 I WL-5 A-s I COURTYARD (OPEN TO ABOVE) IQ A-3 VIA LVR AL-6 ., A-9 • I PL-5 17 CAP OFFICE \ i 1 RL-8 RL 15 15 ENTRIST RL-8 RL-B 5 15 IoRL-8 • 15 RL-8 „G"I 15 ik. k. 1 - 9 -9 1 3 1 - 9 1 1 1 1 13b I 1� Q PL-2 PL-2 13b 13b rI4—mi KITCHEN RL-7 104A 13a 13a QRL-2 QRL-�RL- E 13a os 13a 2 • 13a S ORL-2 13c RL-2 13c RL-2E PL-4 13 101 FUTURE DETO)L NC 1 PL-4 13 PL-4E PHYS TRAI L'Y 4 13 106 13 a PL-4 13 PLC 13 1: RL-2E 13c RL-2 ®O v L_2E• X 13c 1 -- a PL-4 13 PL-4E 13 RL-2 013c A- 4 DAYROOM 104E RL-2 Q13c P �L- 13 A-13 LLVVR 105 a 1 SHEET NOTES: 1. REFER TO ARCHITECTURAL PLAN, REFLECTIVE CEILING PLAN, AND ELEVATIONS FOR EXACT LOCATIONS OF LIGHT FIXTURES. VERIFY, COORDINATE AND PROVIDE REQUIRED FIXTURE TRIMS TO MATCH CEILING SYSTEM. 2. CONNECT ALL LIGHT FIXTURES TO DESIGNATED ASSIGNED CIRCUIT SHOWN. PROVIDE CONTROL WRING TO NOTED CONTROL SWITCHES AND DEVICES TO CONTROL FIXTURES WITHIN ROOM/AREA. 3. EXIT SIGN FIXTURES AND FIXTURES WITH EMERGENCY BATTERY PACKS SHALL BE PROVIDED WITH UNSWITCHED CIRCUIT FOR CONNECTION TO FIXTURE'S BATTERY CHARGING UNIT. • WL-4A GAS METER ALCQVE TING CONTROL PANEL (LVR) PL-3 • SL-6A -6A ' SL-6 SL-6 SL-6 SL-6 -= -- A-9 VIA LVR 1"-2#10& 1#12GND N A-9 VIA LVR 1"-2#10 & 1#12 GND FIRST FLOOR - LIGHTING SCALE: 1/8" =1'-0" FLAG NOTES: POWER CONNECTION TO LED BACK LIT NUMBER SIGNS. REFER TO LIGHT FIXTURE SCHEDULE FOR SL-3 REQUIREMENTS. SURFACE MOUNTED CANOPY LIGHT FIXTURE. TWO (2) TYPE SL-6A MOUNTED UNDER CANOPY AND FOUR (4) TYPE SL-6 MOUNTED TOP OF CANOPY TO ILLUMINATE SIGN. REFER TO ARCHITECTURAL DETAIL FOR MOUNTING LOCATION. CFli-T. OF 3 4/5/19 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com ® 2018 Weinstein A+U -These documents have been prepared specifically for the above named project. They we not suitable for use on other projects or in other locations withal the approval and participation of the Architect r REVIEWED F514- .' OOMPLIANCE WITH! NEPA 70-NEC Ij3j Nv'la; 2010 City of Tukwila BUILDING DIVISION JURISDICTIONAL APPROVAL STAMP Issue Date Sheet Title Sheet REVISED BID SET 1/17/19 FIRST FLOOR - LIGHTING E201 ARCHITECTS + URBAN DESIGNERS ELi 9-0516 to I PL-7 21 MECp ORCH 203 PL-7 21 to PL-1 21 CP PL-1E 21 MECH PLATFORMri 202 21 to PL-3 21 STORAGE D mH' II /lam A-21 PL-3 21 A-23 VIA LVR `4 RV N SHEET NOTES: 1. REFER TO ARCHITECTURAL PLAN, REFLECTIVE CEILING PLAN, AND ELEVATIONS FOR EXACT LOCATIONS OF LIGHT FIXTURES. VERIFY, COORDINATE AND PROVIDE REQUIRED FIXTURE TRIMS TO MATCH CEILING SYSTEM. 2. CONNECT ALL LIGHT FIXTURES TO DESIGNATED ASSIGNED CIRCUIT SHOWN. PROVIDE CONTROL WRING TO NOTED CONTROL SWITCHES AND DEVICES TO CONTROL FIXTURES WITHIN ROOM/AREA. 3. EXIT SIGN FIXTURES AND FIXTURES WITH EMERGENCY BATTERY PACKS SHALL BE PROVIDED WTH UNSWITCHED CIRCUIT FOR CONNECTION TO FIXTURES BATTERY CHARGING UNIT. \ FLAG NOTES: 1 ' VACANCY SENSOR SUITABLE // FOR HIGH CEILING MOUNTING. 2 > DAYLIGHT HARVESTING PHOTOCELL SENSOR MECHANICAL PLATFORM & LOWER ROOF - LIGHTING SCALE: 1/8" = 1'-0" C!TYC: ITZMAURICE & ASSOCIATES IMO Wale. An N. SW Sena 'AOMB r 206415.7211 1106.215,MS 3 4/5/19 Addendum 9 16 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.coni V 2018 Weinstein MU - These documents have been prepared specifically for the above named project. They am not suitable for use on other projects or in other bmtorre without the approval and partlopstlon of the Architect i VI' JFD Ott, i I GOMPLIANC NJ!TKi f NFPA 770 - NEC I UV 2019 9 qn�n Ile f City of Tukwila BUILDING DIVISION ; JURISDICTIONAL APPROVAL STAMP Issue Date REVISED BID SET 1/17/19 MECHANICAL Sheet Title PLATFORM & LOWER ROOF - LIGHTING ARCHITECTS -F URBAN DESIGNERS ELi 9-0516 Sheet E202 EUH-1 MDP-13,15,17 1.5"- 4#3 81#6 GND wP. OF1 43 BREATHING AIR COMPRESSOR MOTORIZED DAMPER M-82,84 MOTORIZED DAMPER UNDER COUNTER REFRIG. M-61,63 M-65 wP On a M-17 EUH-4 PANEL M — COMP-2 AIR COMPRESSO CORRIDOR LEAN a136 +30" c 52 an 17111 EUH 3 CORRIDOR '--_131cf 'It' Y 'If an4h17 YIP 24• GARAGE DOOR vIP CONTROLLER J 44 CFI ' 1 2D WITH RECEPTACLE A 5-30R M-77 PART WASHER NEMA G-20R HUBBELL 2320A M-81,83 EU H-1 M-8 M-67,69 GARAGE DOOR M-79 CEILING FAN SWITCH DROP CORD WITH RECEPTACLE 20A,NEMA 5-20R GARAGE DOOR CONTROLLER M-8,j,87,89 CEILING FAN SWITCH CEILING FAN SWITCH 1 24" WP Gil 48 46' +WI' M-91, 93,95 A-30 FM-20& nr \PANEL1� 1fi5 flJon 126. 65 DU-1 AUCET --131 qp6 11g3,40,42 CTOR—�� 1167 GEAR STOR 129 B-24,26 B-47,49 HRV-2 BC-1 STATION OFFICE • 107 BUZZER 4a, ®CFI A-42,44,46 WP FOUR -FOLD DOOR MOTOR 208V, 30 OVERHEAD MDF RACK', RECEPTACLE 661 LAUUi/JA EUH-7 117 CCTV PANEL ACCESS CONTROL/ SE • EL B-87,89 MASTER CLOCK 45 +36" BUNK 121 F 4V-i 121A B-29,3 CORRIDO 103 -F37,39 CAPOF-CE C 108 . GENERATOR ANNUNCIATOR RECESSED IN WALL A-43,45 BUNK S AID ENTRY VESTIB 4)33 101 DISPO E A-20 -3 -63 On B-21,23 B-25,27 A-47,49,51,53 -69,71,73,75 2 COURTYARD (OPEN TO ABOVE) B-72 OI1 wPq 141 GAS INGNITER SWITCH B-GF1 ® A50 GAS SOLENOID VALVE KITCH+ CFI 04 +30' _t A7476 INSTA 76 " 70 HOT _ 60 I DISH ��`•' .._. _ B-81,83 A-52,54 WASHER AUTO DOOR ASSIST 0.6KVA, 120V GAS RANGE IGNITER SWITCH A-68,70,72 IDU-12 FUTU 68 DETO MC B-68,70,72 48 PH S TRAIN 79 106__j B-16,18 75 �IDU-13 B-74,76,78 B-75,77,790r+72", TV 724111170 F COFFEE MAKER TO EF-8 56 FLAG NOTES: PLUG MOLD WITH DUPLEX RECEPTACLES AS SHOWN. NOT USED LINE VOLTAGE THERMOSTAT. PROVIDE POWER CONNECTION. COORDINATE WITH MECHANICAL FOR CONTROL OPERATION. NOT USED FLUSH FLOOR DUPLEX OUTLET. CONNECTION FOR CO/NO2. PROVIDE SWITCH AND LINE VOLTAGE BELL AS REQUIRED. NOT USED NOT USED REMOTE CONTROL SIGNAL RECEIVER TO OPEN GARAGE DOOR. PROVIDE CONTROL WIRING TO INTERFACE WITH ACCESS CONTROL PANEL. GARAGE DOOR PHOTO -EYE SENSOR, +36"AFF FOR GARAGE DOOR TO AUTO CLOSE. WALL MOUNTED TIMER SWITCH TO INTERFACE WITH HOOD EXHAUST FAN AND MOTORIZED DAMPER. COORDINATE WITH MECHANICAL FOR CONTROL OPERATION. - --- LINE VOLTAGE THERMOSTAT, CONNECT TO EF-8 POWER. INTERFACE OPERATIONS TO EXHAUST FAN AND MOTORIZED DAMPER. COORDINATE WITH MECHANICAL FOR CONTROL OPERATION. >PROVIDE 11.0KVA BUCK/BOOST TRANSFORMER MOUNTED IN ACCESSIBLE CEILING TO BOOST VOLTAGE FROM 108V, SINGLE PHASE TO 240V, SINGLE PHASE SERVING THE DUAL FUEL RANGE. GAS SOLENOID VALUE CONTROL PANEL MOUNTED IN ACCESSIBLE CEILING. REFER TO CONTROL DIAGRAM 1/E7.01. COORDINATE FINAL LOCATION WITH MECHANICAL. OCCUPANCY SENSOR WITH RELAY PACK TO CONTROL RECEPTACLE WITHIN ROOM/AREA. r PORTABLE GENERATOR QUICK CONNECTOR BOX ;Sic B-74 CT ENCLOSURE AND METER FIRE ALARM PANEL (FACP) PANEL B PANEL A LIGHTING RELAY PANEL LVR ALERTING CONTROL PANEL ATS-MDP MTS-MDP MAIN DIST PANEL (MDP) �( FIRST FLOOR - POWER N 1 SCALE. 1/8" = 1' 0" GEN. SET TO ATS-MDP GEN L003 29 A-25,27,29 1"-5#10& 1#12 GND 25,27 RASR- 002 BATTERY CHARGER BLOCK/COOLANT HEATER CITY OF TUKWILA OCT 2 1 2019 PERMIT CENTER TRAVIS ASSOCIATES 12N Vitstirbc Ave tt.&It 509 V2Oi.8S I12tl ITZMAURICE . A BRIO] 1202920ST2N 32 10/17/19 ASI-007 3 4/5/19 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.welnsteinau.com 02018 Weinstein AFU - These documents have been prepared specifically for the above named project. They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. ( FIEv EWER FOF1 100 PLIANCE WITH • t NFPA 70 - NEC 1 1 i City of Tukwile BUILDING DIVISION i.w 11 2819 JURISDICTIONAL APPROVAL STAMP Issue Date Sheet Title Sheet REVISED BID SET 1/17/19 FIRST FLOOR - POWER E301 ARCHITECTS + URBAN DESIGNERS �F EL19-0516 BID ALTERNATE #3 M-47 VEF M-57 M-11 EUH-5 P M-39,41 EF-5 15 M-53 E J MECH PORCH -326 28 30 11tglc r EF 3 }F4 IF �� M-55 M-3 -2 EF- 2 M-49 M-35,37 MECH PLATFORM 202 15 13 13 DHWH-1 (�-74 fff OHWH-2 M 51 UH-2 M-78 qiitiV5/ M-76 —COMP-1 AIR —1 -401U • COMPRESSOR UH-1 c • M9 M-54,56 M-58,60 M-1 CF-1 —CF-2 MOP-19,21,23 2"-4#310 & 1#4 GND MAGNA-RAIL 1.0KVA,208V,10 WAS B-36 `. N MDP-20;22,24 1.25"-4#4 & 1#8GND B-36 0 0 B-36 C41�,.4111 MI ifs 00U OUTDOOR UNIT ODU MOD2 VRF-ODU MOD1 B-36 MOTORIZED DAMPER IMP-14,16,18 1.25"-4#4 & 1#BGND B-34 'II II II l c ■ B-32 RV B-36 MOTORIZED DAMPER B32 cn EF B-30 N EF-8 FLAG NOTES: MOUNT DUPLEX OUTLET ADJACENT TO DISCONNECT SWITCH ON UNI-STRUT. >LINE VOLTAGE THERMOSTAT. PROVIDE POWER CONNECTION. LINE VOLTAGE THERMOSTAT TO INTERFACE WITH EXHAUST FAN AND MOTORIZED DAMPER OPERATION. COORDINATE MECHANICAL FOR CONTROL OPERATION. TO LINE VOLTAGE THERMOSTAT AT ELEC. ROOM 105. MECHANICAL PLATFORM & LOWER ROOF - POWER SCALE: 1/8" =1'-0" • Lrt ITZMAURICE dAS50Cl6TES 12Ve Woos* 4v.. N. AS Smite. .a0 ome.2as.m" r2oesauw 3 415/19 Addendum 9 1B 12111/18 Design Revisions 1A 12111/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 0 2018 Weinstein MU - These documents have been prepared specifically for the above named project. They are not suitable for use on other projects or in other locations without the approval and participation otthe Architect. c-f4EV"-- IEWV G F-lP1 '.GO FPIANCEdE r'I I e I:_': 1... Z019 = City cl Tukwil+t i BUILDING DIVISION JURISDICTIONAL APPROVAL STAMP Issue Date Sheet Title Sheet REVISED BID SET 1/17/19 MECHANICAL PLATFORM & LOWER ROOF - POWER E302 N A+ U ARCHITECTS+ URBAN DESIGNERS L.LJ ELi 9-0516 2"c, STUB AND CAPPED AT ROOF FOR FUTURE PV SYSTEM MOTORIZED DAMPER IC-wp tM-9 EF-8 M-20,22,24 0 0 0 2"e, STUB AND CAPPED AT ROOF FOR FU MOTORIZED RE PV SYSTEM TO ELEC. ROOM TO ELEC. ROOM J / A \ I 1 UPPER ROOF PLAN - POWER SCALE: 1/8" =11-0" FLAG NOTES: 1 > MOUNT DUPLEX OUTLET ADJACENT TO DISCONNECT SWITCH ON UNI-STRUT. Ci1Y ITZMAURICE : ASS taus 1200 WwSb Are. N. AN , SOD 5re e.'WA lA 9206.295.7221 12064511294 3 4/5/19 Addendum 9 18 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 02018 Wein:dein A+U - These documents have been prepared specifically for the above named project They are not suitable the use on other projects or in other locations without the approval and beradpaton of the Archftect. y' REVIEWED FOR t �NrpA. 70C'NECE � i t City of Tukwila ' BUILDING DIVISION I::: 1 2019 JURISDICTIONAL APPROVAL STAMP Issue Date REVISED BID SET 1/17/19 Sheet Title UPPER ROOF PLAN - POWER ARCHITECTS + URBAN DESIGNERS D z to z a ELi 9-0516 Sheet E303 C STOR 138! SCBA 137I CORRIDOR 135 it VP CLEAN 136 a_ -L I 0 BREATHING AIR COMPRESSOR COMM. LINES K f SHOP 134 iuP EMS 132 CORRIDOR 131 MECH 133' W, APP BAY 130 COMM. BOARD TEUINTERNET/CATV DEMARC. 6 HIGH x 1" THICK FIRE RATED PLYWOOD (2)2"C WITH RADIO ANTENNA CIRCUIT ELECTRONIC WAP DECON AST CL e K M. INE ASH GEA STOR 1r9 RECEIV 122 AIRLOCK 123 , LA UN/JA 117 ADA BAT 113 DOOR BUZZER GROUND TERMINATION COPPER BAR MDF RACK 4 POST, BOLT ON FLOOR CCTV PANEL COMM. LINES ACCESS/SECURITY COMM. LINES BUNK 121', N, 121A WAP CORRIDOR EMERGENCY CALL PHONE OUTLET MOUNTED ON PEDESTAL. COORDINATE WITH ARCHITECTURAL PLAN. PROVIDE EMERGENCY CALL PHONE. VIKING SECURITY AND COMMUNICATIONS E-1600A-EWP. BUNK 114 CAP BUNK 112 ENTRY VESTIB L 101 TO MDF OOR BUZZER PUSH BUT -ON. MOUNTED ON MULLION. COORDINATE WITH ARCHITECTURAL PLAN. COURTYARD (OPEN TO ABOVE) PHYS TRAIN 106 • 1NAP V FUTURE DETOX, NIC SHEET NOTES: 1. HOMERUN DATA AND VOICE TO MDF RACK. CABLES SHALL ROUTE IN CONDUIT (1" EMT MINIMUM) WHERE IN WALLS, ABOVE NON -ACCESSIBLE CEILINGS AND EXPOSED. OPEN CABLING ALLOWED ABOVE ACCESSIBLE CEILING. 2. HOMERUN TV CABLES TO TELEVISION DEMARC BOARD. CABLES SHALL ROUTE IN CONDUIT (1" EMT MINIMUM) WHERE IN WALLS, ABOVE NON -ACCESSIBLE CEILINGS OR EXPOSED. OPEN CABLING ABOVE ACCESSIBLE CEILINGS. FLAG NOTES: COORDINATE WITH OWNER FOR FINAL LOCATION OF RADIO SYSTEM EQUIPMENT PRIOR TO ROUGH -IN. FIRE ALARM PANEL COMM. LINES ALERTING PANEL COMM. LINES FIRST FLOOR - COMMUNICATIONS SCALE: 1/8" = 1'-0" Nan ITZMURICE A 1ASSOCKTES I1 Ow.m.i.Ar1 rt. VS 5101. WA 10109 1 264.211712i M12152294 3 4/5/19 Addendum 9 18 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 02018 Weinstein M U - These documents have been prepared specifiealy for the above named project. They are not suitable for use on other projects or in other locations without the approval end participation of the Archtect R V4tWEETF�J' tut `• COMPLIANCE 1MYM i I TOP:, 70 - NEC I I I IIJ: 1 1Yqr1 1 i 1 City of Tuxvnla UUILOING DIVISION JURISDICTIONAL APPROVAL STAMP Issue Date REVISED BID SET 1/17/19 ARCHITECTS + URBAN DESIGNERS ELi 9-0516 • Sheet Title FIRST FLOOR - COMMUNICATIONS Sheet E401 I.S MECH PORCH 203 TO MDF AN / C (4)4"C WITH RADIO ANTENNA CIRCUITRY TO COMM. RM 127. PROVIDE 2" WEATHERHEAD FOR EACH CONDUIT STUB ON ROOF MECH PLATFORM 202 STORAGE 201__ l 1 1#2/0 BC TO GROUND 00 re I FLAG NOTES: PROVIDE RADIO ANTENNA MAST. MOUNTED ON UPPER ROOF. ANTENNAS SHALL BE MONOPOLE OMNI DIRECTIONAL ANTENNA WITH N CONNECTOR FOR RADIO 800 MHZ, DIAMOND X5ONA 144/440 MHZ BASE FIBERGLASS VERTICAL ANTENNA, 66" TALL, N CONNECTOR FOR D-STAR HAM RADIO 144/440 MHZ AND 1.2GHZ MAGI ANTENNA AIMED AT REPEATER AT THE OLD STATION 51 FOR DATA HAM RADIO 1.2 GHZ. PROVIDE REQUIRED MOUNTING BRACKET AND SUPPORT STRUCTURE. COORDINATE FINAL LOCATION WITH ARCHITECT. p ' STUB CONDUIT AT COMM. ROOM 127. PROVIDE RADIO ANTENNA CABLE TO MATCH EXISTING. COORDINATE WORK WITH OWNER. 1 RV El j EF N MECHANICAL PLATFORM & LOWER ROOF - COMMUNICATIONS SCALE: 1/8" = 1'-0" e ASSoct4TEs 12WWaw Ave N.S. s Suitt A I/I09 94140t7I2S rtaaillal ITZMAURICE titer 3 4/5119 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Westem Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 02018 Weinstein MU - These documents have been moored specifically for the above named poled. They am not suitable for use on otter projects or In other locations without the approval and partdpaton of the Architect I00 PL ANCVVEDE WaM NFPA 70-NEC 1.,.11 2019 1 1 Clty of '. ukvila ttUILDING 3IVISIO' JURISDICTIONAL APPROVAL STAMP Issue Date REVISED BID SET 1/17/19 MECHANICAL Sheet Title PLATFORM & LOWER ROOF - COMMUNICATIONS Sheet ARCHITECTS -I- URBAN DESIGNERS NSTEINA+U EL1 9-0516 P RtXT cc:'El-:P E402 W 3 c STOR Tin _138 UP CORRIDOR 135 EMS 132 ; C 131 DOR MECH 133 TO FACP L APP BAY 1 TO ACP Ltr VYC 126. i TO ACP DECON 126 FM-200 SYSTEM CONTROLLER CLOSE CIRCUIT TELEVISION ZNTROLLER(CCTV) CESS CONTROL PANEL (ACP) 127 TO FACP CEIV 22 MASTER CLOCK CONTROLLER-" tEA WASH 128,. LI LI i LAUNIJAN\ 117_._. ).C, IT GEAR STOR 129 STATION OFFICE 107 BATH I11 COR !DOR TOACCP 1 9 R sg 11 FA 11S FAC i R©. R© `qV9 I Rey SO SD A TO I APA BATA 110 [R© A-41 O CORRIDOR 103 A'DA 102_: - CAP OFFICE 108® FIRE ALARM ANNUNCIATOR .A FA TO FACP 1" C WITH FIRE ALARM WIR NG TO FACP TO FACP TO FACP TO FACP COURTYARD (OPEN TO ABOVE) NTRY VESTIB 101 TO ACP AC L KITCHEN 104A rri DAYROOM 104E PHTRAIN if FUTURE DETOX, NIC ELEC 105 GAS E :R SHEET NOTES: 1. PROVIDE FIRE ALARM CIRCUITRY AS REQUIRED BY MANUFACTURER TO ALL FIRE ALARM DEVICES. ROUTE CIRCUITRIES IN RACEWAY (3/4" EMT MINIMUM), WHEREIN WALLS NON ACCESSIBLE CEILING OR EXPOSED. OPEN CABLING ALLOWED IN ACCESSIBLE CEILINGS. 2. PROVIDE ACCESS CONTROL AS REQUIRED BY MANUFACTURER FOR ALL ACCESS CONTROL DEVICES. ROUTE CIRCUITRY IN RACEWAY (3/4" EMT MINIMUM) AND CONNECT TO ACCESS CONTROL PANEL. 3. PROVIDE CCTV CIRCUITRY AS REQUIRED BY MANUFACTURER FOR ALL CCTV CAMERAS. ROUTE CIRCUITRY IN RACEWAY (3/4" EMT MINIMUM) WHERE IN WALLS, ABOVE NON -ACCESSIBLE CEILINGS OR EXPOSED. CONECT ALL CCTV CIRCUITRY TO CCTV CONTROLLER. 4. PROVIDE CLOCK SYSTEM CIRCUITRY AS REQUIRED BY MANUFACTURER. ROUTE CIRCUITRY IN RACEWAY (3/4" EMT MINIMUM). CONNECT ALL CIRCUITRY TO CLOCK SYSTEM CONTROLLER. IRE ALARM PANEL (FACP) TO CCTV -HE FLAG NOTES: MOUNT CARD READER IN DOOR MULLION FIRST FLOOR - FIRE ALARM/SECURITY/CLOCK SCALE: 1/8* = CCTV GEN 003 TRASH 002 &A O TE 11aatwas/ra N.f,U pmm4m rsswrm 3 4/5/19 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections#1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com C 2018 Weinstein A+U - These documents have been prepared specifically for the above named project. They am not suitable for use on other projects or In other locations without the approval and participation of the Architect VI G FO1fii GOMP'UPINCF� WITH NF?c, P i t;; ! 1 2019 f • City 01 Tukwila suit DING DIVISION .1 JURISDICTIONAL APPROVAL STAMP Issue Date REVISED BID SET 1/17/19 ARCHITECTS + URBAN DESIGNERS ELi 9-0516 Sheet Title FLOOR PLAN - FIRE ALARMISECURITYICLOCK Sheet E501 MECH PORCH 203 MECH PLATFORM 202 I/ L STORAGE e 201 (Zh • .I.; h. 1 0 0 1F1 I V, I Ii EF SHEET NOTES: 1. PROVIDE FIRE ALARM CIRCUITRY AS REQUIRED BY MANUFACTURER TO ALL FIRE ALARM DEVICES. ROUTE CIRCUITRIES IN RACEWAY (3/4" EMT MINIMUM), WHEREIN WALLS NON ACCESSIBLE CEILING OR EXPOSED. OPEN CABLING ALLOWED IN ACCESSIBLE CEILINGS. 2. PROVIDE ACCESS CONTROL AS REQUIRED BY MANUFACTURER FOR ALL ACCESS CONTROL DEVICES. ROUTE CIRCUITRY IN RACEWAY (3/4" EMT MINIMUM) AND CONNECT TO ACCESS CONTROL PANEL. 3. PROVIDE CCTV CIRCUITRY AS REQUIRED BY MANUFACTURER FOR ALL CCTV CAMERAS. ROUTE CIRCUITRY IN RACEWAY (3/4" EMT MINIMUM) WHERE IN WALLS, ABOVE NON -ACCESSIBLE CEILINGS OR EXPOSED. CONECT ALL CCTV CIRCUITRY TO CCTV CONTROLLER. 4. PROVIDE CLOCK SYSTEM CIRCUITRY AS REQUIRED BY MANUFACTURER. ROUTE CIRCUITRY IN RACEWAY (3/4" EMT MINIMUM). CONNECT ALL CIRCUITRY TO CLOCK SYSTEM CONTROLLER. MECHANICAL PLATFORM & LOWER ROOF - FIRE ALARM/SECURITY/CLOCK SCALE: 1/8" = 1'-O" t :1[: .EN.E— J C:TYu: E4iC:�it_'. ITZMAURICE &ASSOQATES IX9 N.494,. M. SOS 539 pN0 y5•Pna 5.101*.'AA iA109 IID&2r53294 3 415119 Addendum 9 1 B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 02018 Weinstein A+U • These documents have been prepared spedficalh for the above named project They are not suable for use on other projects or in other Iocebwm viitoA the approval and participation of the Architect. REVIEWED FOR COMPLIANCE WITH] I NFPA7m-NEC TO% City i f Tukwii3 j BUILDING DIVISION JURISDICTIONAL APPROVAL STAMP Issue Date REVISED BID SET 1/17/19 MECHANICAL Sheet Title PLATFORM & LOWER ROOF - FIRE ALARM/SECURITY/CLOCK ARCHITECTS + URBAN DESIGNERS ELi 9-0516 ¢W�•...r L.-. t .,F.11 L• ,C 1 r Sheet E502 FUTURE CHECK -IN STATUS PANEL AT BUNK ROOM (TYP. FOR 6) STROBE LIGHT AT PHYSICAL TRAINING TO 120V CIRCUIT ALERTING SYSTEM COLORED INDICATING LIGHTS SPEAKERS, SEE FLOOR PLAN FOR LOCATIONS, QUANTITIES AND TYPES (TYP) TO 120V SOURCE ALERTING SYSTEM STATION CONTROLLER TO 120V SOURCE PAGING AMPLIFIER CABINET STOR _ 138: CORRIDOR 1- .. 135 .i EMS 132 -- LIGHTING CONTROL SYSTEM —I GAS SOLENOID FOR RANGE --I GAS SOLENOID FOR BBQ PAGING ZONE #1 -APPARATUS BAY PAGING ZONE #2 - STATION OFFICES PAGING ZONE #3 - COMMON AREAS PAGING ZONE #4 - BUNK ROOMS © PAGING ZONE #5 - DOOR CHIME .31 ALERTING MESSAGE SIGN. SEE FLOOR PLAN FOR LOCATIONS AND QUANTITIES. GAS SOLENOID VALVE CONTROL PANEL. REFER TO 2/E6.1 ALERTING SCHEMATIC NTS ALERTING STROBE -TO ALERTING PANEL ALERTING STROBE VYC ;125 APP BAY 130 DECON 126 COMM 127 00 7 A AIRLOCK TO ALERTING PANEL CONNECT TO ADJACENT DUPLEX OUTLET CIRCUIT RECEIV 122 OPTICOM TRAFFIC CONTROL PANEL TRAFFIC CONTROL MOMENTARY SWITCH CONNECT TO ADJACENT DUPLEX OUTLET CIRCUIT TO SIGNAL EMITTER A; 128 GEAR STOR 129 AIRLOCK 109 1: l II571 STATION OFFICE 107 LAUN/JA S, 117 a ?Et BATH -C-3)� 115. ADA BAT 113 BATH 111! 1 ‚-4 121A CORRIDOR 119 118A' CORR 110. 1144 ?Ai CORRIDOR 103, _ 120 120A BUNK 118 BUNK 116 BUNK 114 AY BUNK 112 ADA 102 CieP OFFICE 108 _. ENTF I VESTIB 101 UI I! COURTYARD (OPEN TO ABOVE) ALERTING STROBE KITCHEN ! 104A: • FUTURE DE X MC PHYS TRAIN 106 CONNECT TO ADJACENT DUPLEX OUTLET CIRCUIT. TO ALERTING PANEL DAYROOM 1048 1 SHEET NOTES: 1. PROVIDE ALERTING SYSTEM CIRCUITRY AS REQUIRED BY MANUFACTURER. ROUTE ALL CIRCUITRY IN RACEWAY (314" EMT MINIMUM). CONNECT ALL CIRCUITRY TO ALERTING SYSTEM CONTROL PANEL. ALERTING SYSTEM COLOR CODED INDICATING LIGHTS (PROVIDE 4 COLORS) TO ALERT1 PANEL GAS METER a AL VE EL EC v� 105 ALERTING SYSTEM CONTROLLER FLAG NOTES: BUNK ROOM FUTURE CHECK -IN STATUS PANEL. PROVIDE ROUGH -IN BOX AND CONDUIT TO ALERTING CONTROLLER. A TO ALERTING PANEL FIRST FLOOR - ALERTING SYSTEM N SCALE: 1/8" =1'-0" /S -4- GEN 0031 L TRAS}I- 002 J Cif1 yr i i%N i.., . PER2iT _. Ta &ASSOCWIS tags PrN.ar rarm73r ITZMAURICE tl1iyL7fM 3 4/5119 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com C 2018 weinabin MU • These doaments have been prepared specifically for the above named project. They are not suitable for use on ether projects or in other locations without the approval and participation of the Architect - VIr 1F.^. 511 ! COMPLIANCE WITH NFPF. C .. IIEC I;.. L. 2019 City M TUKwifa BUILDING DIVISION 1 JURISDICTIONAL APPROVAL STAMP Issue Date REVISED BID SET 1/17/19 ARCHITECTS + URBAN DESIGNERS ELi 9-0516 Sheet Title FIRST FLOOR - ALERTING SYSTEM Sheet E601 - MECH PORCH 203 DN A '� TO ALERTING PANEL MECH PLATFORM 202 STORAGE 201 00 I - ICI 00 0 I W SI SHEET NOTES: PROVIDE ALERTING SYSTEM CIRCUITRY AS REQUIRED BY MANUFACTURER. ROUTE ALL CIRCUITRY IN RACEWAY (3/4" EMT MINIMUM). CONNECT ALL CIRCUITRY TO ALERTING SYSTEM CONTROL PANEL. MECHANICAL PLATFORM & LOWER ROOF - ALERTING SYSTEM SCALE: 1/8" =1'-0" C: e `1• V: E l,`.N. t!... ITZMAURICE & ASSCCtTES 12%Antee"Ati N. sa 5)9 p 33.1.2151228 Se WA 101% 1.2M 2e5 1Ss 3 4/5119 Addendum 9 1B 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein MU Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 02018 Weinstehl AEU - These documents have been prepared specifically for the above named project They am not suitable for use on other projects or in other locations without the approval and participation oldie Architect. RtvlEWED Ft_1Ft • COMPLIANCEl?VNTH! . 1 te. ! 1 •: 2019 City of nitwits I 8UILOING DIV!SION JURISDICTIONAL APPROVAL STAMP Issue Date Sheet Title Sheet REVISED BID SET 1/17/19 MECHANICAL PLATFORM & LOWER ROOF - ALERTING SYSTEM E602 ARCHITECTS + URBAN DESIGNERS D a z I tIn z ELi 9-0516 GROUNDING CONDUCTOR UNGROUNDED CONDUCTOR NC OPTICUM 794M EMITTER CABLE SUPPLIED WITH EMITTER, MAXIMUM LENGTH 25 FEET. DO NOT SPLICE JUNCTION BOX 120V TO 12V DIC 5 AMP POWER SUPPLY INGRAM PART #PSD60.12 TIME DELAY RELAY/DELAY OFF MACROMATIC RELAY PART # TR-51622-13 AND SOCKET PART #70170-D GROUNDED CONDUCTOR NC 120V RATED MOMENTARY SWITCH TRAFFIC SIGNAL EMITTER WIRING DIAGRAM NTS r1 LOCATED AT APPARATUS BAY CPI CHATSW❑RTH 4X10 GROUND BUS BAR KIT W/ WALL M❑UNTING BRACKETS AND INSULATORS #10622-010 GROUND BAR ASSEMBLY NTS 1" C, 3#12 120V, MOMENTARY PUSH BUTTON LOCATED AT EXIT GATE (SEE SITE PLAN) R1 TIMER R2 CONTROL R4 AAS SOLENOID R3/ COOKTOP, OVEN, R4 BBQ SOLENOID C1 DISPATCH STROBE C2 RANGE PHOTODIODE ASSEMBLY MOUNTED ON PARKING LIGHT POLE, AT 81-6" ABOVE FINISH GROUND. PROVIDE REQUIRED MOUNTING ACCESSORIES. ROUTE PORTIONS OF CABLES INSIDE POLE 1/C-2#18 CONTROLLER J.BOX 12" X 12" X 6" DEEP NEMA 3R MOUNTED ON STEEL UNI-STRUT AT 6" ABOVE FINISH GROUND POWER SUPPLY MODULE/RELAY PLUG-IN 12 VAC TRANSFORMER. PROVIDE DUPLEX OUTLET INSIDE ENCLOSURE. 120V SOURCE CIRCUIT A-39 1/C-2#18 SHIELDED CABLE ROUTE PORTIONS OF CABLES IN 1" CONDUIT CONTROLLER CIRCUIT BOARD "C-2#18 & 1#14 GND TO GATE CONTROLLER/OPERATOR FIRE STROBE 2000 EMERGENCY VEHICLE STROBE DETECTOR GATE OPENER SCHEMATIC DIAGRAM NTS 0.0 TO 2 MIN ADJUSTABLE OFF DELAY ON/OFF NO DELAY ON/OFF NO DELAY ON/OFF NO DELAY HOLDING CONTACT 600V/20A/3 POLE DEFINITE PURPOSE CONTRACTOR SQUARED CLASS 8910 120V/20A/1 POLE/NEMA CONTRACTOR SIZE 2 IN SEPARATE NEMA 1 ENCLOSURE. SQUARE D CLASS 8502 RELAY R1 TO BE SQUARE D CLASS 9050-JCK70 TIMING RELAY, SET FOR TIME DELAY ON DROP OUT AT 2 MINUTES. OTHER RELAYS TO BE SQUARED CLASS 8501. RUN 2-CONDUCTOR CONTROL ALERTING SYSTEM CONTROLLER. MOUNT RELAYS IN 18"X18"X4" MINIMUM DEEP HINGED RELAY CABINET. PROVIDE 100VA MINIMUM 120/24V CONTROL POWER TRANSFORMER & 5A FUSES. 120 VAC N 24V 5A R1 n LOCUTION _ I TDDO I LED LIGHTS ALERTING R2 SYSTEM /R2 C1 R1 TDDO R3 -Il RESET PUSHBUTTON R4 di RESET PUSHBUTTON DISPATCH STROBES R2 R2 R3 .YC R3 GAS RANGE SOLENOID R2 R4 H ® R3 R4 Ida GAS BBQ GRILL SOLENOID GAS RANGE AND BBQ GRILL CONTROL RELAY PANEL DIAGRAM NTS C2 GAS RANGE RE -STRIKE IGNITION POWER MECHANICAL/PLUMBING EQUIPMENT SCHEDULE MOTOR ELECTRICAL DATA ELECTRICAL CONNECTION EFFICIENCY REMARKS EQUIPT (%) W/KW/HP VOLTS PHASE AMPS CONNECTION IDU-1 0.21 KVA 208 1 1 SEE AC IDU-1!ODU-1 IDU-2 0.07 KVA 208 1 0.34 DISC. SW. IDU-3 0.07 KVA 208 1 0.34 DISC. SW. IDU-4 0.07 KVA 206 1 0.34 DISC. SW. IDU-5 0.07 KVA 208 1 0.34 DISC. SW. IDU-6 0.07 KVA 208 1 0.34 DISC. SW. IDU-7 0.07 KVA 208 1 0.34 DISC. SW. IDU-8 0.08 KVA 208 1 0.39 DISC. SW. IDU-9 0.08 KVA 208 1 0.39 DISC. SW. IDU-10 0.69 KVA 208 1 3.33 DISC. SW. IDU-11 0.47 KVA 208 1 2.25 DISC. SW. IDU-12 0.69 KVA 208 1 3.33 DISC. SW. IDU-13 0.69 KVA 208 1 3.33 DISC. SW. ODU-VRF-MOD1 89.5 15.12 KVA 208 3 42 DISC. SW. ODU-VRF-MOD2 89.5 15.12 KVA 208 3 42 DISC. SW. HRV-1 .65 KW 208 1 3 DISC. SW. HRV-2 1.3 KW 208 1 6 DISC. SW. HRV-3 0.3 KW 208 1 1.4 BC-1 0.21 KVA 208 1 1.08 DISC. SW. RHRV 91.7 66.6 KVA 208 3 185 DISC. SW. 200A13 MOCP CF-1 100 W 120 1 J. BOX/HARDWIRED NOTE 5 CF-2 100 W 120 1 J. BOX/HARDWIRED NOTE 5 CF-3 100 W 120 1 J. BOX/HARDWIRED NOTE 5 CF-4 100 Vd 120 1 J. BOX/HARDWIRED NOTE 5 EF-1 250 Vd 120 1 DISC. SW./STARTER NOTE 2 EF-2 500 VI 120 1 DISC. SW./STARTER NOTE 2 EF-3 50 W 120 1 DISC. SW./STARTER NOTE 2 EF-4 350 W 120 1 DISC. SW.ISTARTER NOTE 2 EF-5 125 VI 120 1 DISC. SW./STARTER NOTE 2 EF-6 77 0.75 EP 208 3 3.5 DISC. SW./STARTER NOTE 2 EF-7 1/3 HP 120 1 7.2 DISC. SW./STARTER I NOTE 2 EF-8 1/4 HP 120 1 5.8 DISC. SW./STARTER NOTE 2 EF-9 3/4 HP 120 1 13.6 DISC. SW./STARTER NOTE 2 AC IDU-1 208 1 1 DISC. SW. AC ODU-1 77 208 1 17.1 DISC. SW. 15A/3 MOCP UH-1 0.55 KVA 120 1 4.6 DISC. SW. UH-2 0.55 KVA 120 1 4.6 DISC. SW. EUH-1 2.0 KW 208 1 DISC. SW. EUH-2 1.5 KW 208 1 DISC. SW. EUH-3 1.5 KW 208 1 DISC. SW. EUH-4 1.5 KW 208 1 DISC. SW. EUI4-5 2.0 KW 208 1 DISC. SW. EUH-6 1.5 KW 208 1 DISC. SW. EUH-7 1.5 KW 208 1 DISC. SW. BENCH EXH HOOD 84 1.5 HP 120/208 1 8.5 DISC. SW. VEF 91.7 7.5 HP 208 3 24.2 DISC. SW. NEDERMAN RAIL 77 1 HP 208 1 DISC. SW. COMP-1 89.5 5.0 HP 208 3 16.7 DISC. SW. COMP-2 85.5 2.0 HP 208 1 13.2 DISC. SW. FUEL MGT SYSTEM 77 1.0 HP 120/208 1 J. BOX/HARDWIRED FUEL PUMP 77 1.0 HP 120/208 1 DISC. SW. FUEL DISP 1.0 KVA 120.0 1 J. BOX/HARDWIRED BF-1 260 W 120 RECEPTACLE DI-IWH-1 0.6 KVA 120 1 5 DISC. SW. DI-IWCP 1/4 HP 115 1 5.8 DISC. SW. BREATHING AC 93 20 HP 208 3 59.4 DISC. SW. NOTES: 1) COORDINATE FINAL EQUIPMENT LOCATIONS AND POWER MECHANICAUPLUMBING EQUIPMENT SUPPLIERS. 2) PROVIDE MOTOR STARTER/CONTROLLER AND DISCONNECT ' 3) CONTROLLED BY LINE VOLTAGE THERMOSTAT. PROVIDE 4) PROVIDE INTERFACE WIRING AND DRY CONTACT RELAY CONTROLLER TO INTERLOCKED WITH TUBE HEATERS DOOR OPENS AT APP BAY THE TUBE HEATER WILL THE TUBE HEATER WILL AUTOMATICALLY RESTART. MECHANICAL FOR SEQUENCE OF OPERATION. 5) PROVIDE CONTROL WIRING FROM CEILING FAN TO REQUIREMENTS WITH RELAYS. GARAGE DOOR THE RESPECTIVE DOOR SHUTS WITH SWITCH. REQUIRED CONTACTOR AT RESPECTIVE SUCH THAT WHEN TURN OFF. WHEN THE REFER AND COORDINATE SWITCH. LIGHTING CONTROL SCHEDULE ("LVR") CIRCUIT SWITCH RELAY CONTROL A-1 1 EXTERIOR -PHOTOCELL, TIMER A-3 2 EXTERIOR -PHOTOCELL, TIMER A-5 3 EXTERIOR -PHOTOCELL, TIMER A-7 4 EXTERIOR -PHOTOCELL, TIMER A-7 5 EXTERIOR -PHOTOCELL, TIMER A-9 8 EXTERIOR -PHOTOCELL, TIMER A-11 10 EXTERIOR -PHOTOCELL, TIMER A-13 11 LV SWITCH, DAYLIGHT SENSOR, OCC SENSOR, ALERTING A-15 13 LV SWITCH, DAYLIGHT SENSOR, OCC SENSOR, ALERTING A-17 15 LV SWITCH, DAYLIGHT SENSOR, OCC SENSOR, ALERTING 17 SPARE 18 SPARE 19 SPARE A-23 20 LV SWITCH, DAYLIGHT SENSOR, OCC SENSOR, ALERTING 27 SPARE 28 SPARE 29 SPARE 30 SPARE 31 SPARE 33 SPARE 34 SPARE 35 SPARE 36 SPARE 37 SPARE 38 SPARE 39 SPARE 40 SPARE 41 SPARE 42 SPARE 43 SPARE 46 SPARE 47 SPARE 48 SPARE 49 TO 64 SPARES PEP r.".: CENTER ITZMAURICE [ASSOCIATES i2GCfMSN,A» N.Sw $.Ss WA HAS p216 li7221 1106,2117294 3 4/5/19 Addendum 9 113 12/11/16 Design Revisions 1A 12/11/18 Permit Comsctions#1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 02018 weUshi A+U-These documents have been prepared specifically far the stave named project. They me not suitable tar use on other prtteds or In otherloSiona without the approval and participation at the McNtac. ICOD.4 'r.',Ccf 1.11-•. i:..' 1 2919 i ty el --ukwl s 4111LDiN'G DIVIsiON JURISDICTIONAL APPROVAL STAIR Issue Date Sheet Title Sheet REVISED BID SET 1/17/19 DETAILS E701 ARCHITECTS + URBAN DESIGNERS D Q Z W I Z LLI ELi 9-0516 PANEL MDP LOCATION MOUNTING AIC FED FROM CCT NO. ELEC ROOM 105 SURFACE 65,000 PSE TRANSFORMER CCT DESCRIPTION BRKR VOLTS 208 /120 3 PHASE, 4 WIRE, WYE AMPS 1000 MAIN CIRCUIT BREAKER GROUND BUS SERVICE ENTRANCE LABEL LOAD CCT CCT KVA NO. BRKR DESCRIPTION LOAD KVA I 200/3 PANEL A 3 200/3iPANEL B 80/3 SCBA COMP 200/3iRHRV 100/3iSPARE 20/ SPACE 20/ SPACE 20/ SPACE 20/ SPACE 20/ SPACE 41 20/ SPACE CONNECTED LOAD 5 7 9 II 13 15 17 19 21 23 25 27 29 31 33 35 37 39 KVA 51.69 64.93 21.38 66.60 2 400/3 4 6 8 30/3 10 12 14 16 18 20 22 24 0.00 26 0.00 28 0.00 30 0.00 32 0.00 34 0.00 36 0.00 38 0.00 40 0.00 42 DEMAND FACTOR 6I/3 6I/3 100/3 20/ 20/ 20 20/ 20 20/ PANEL M 73.86 SPD CM -I MOD2 15.12 CM -I MODI 15.12 SPACE SPACE SPACE SPACE SPACE SPACE SPACE DEMAND LOAD 0 00 0,00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 KVA AMPS LIGHTS 7.73 RECEPTACLES 26.64 HEATING 17.50 LARGEST MOTOR 30.09 OTHER MOTORS 137.66 MISCELLANEOUS 89.08 KITCH. APPLIANCES 0.00 PANEL A LOCATION MOUNTING AIC FED FROM CCT NO. 308.70 I SECTION ELEC ROOM 105 SURFACE 42,000 PANEL MDP CCT DESCRIPTION BRKR 25% 00% 00% 25% 00% 00% 00% VOLTS 208 /120 AMPS 225 MLO 9.67 26.64 17.50 37.61 137.66 89.08 0.00 26.83 73.95 48.58 104.40 382.11 247.26 0.00 318.16 883.12 3 PHASE, 4 WIRE, WYE GROUND BUS PROVIDE SURGE PROTECTOR NOTE: *-DENOTES AFC! TYPE BREAKER LOAD KVA CCT CCT DESCRIPTION NO. BRKR LDAD KVA I 20/ 3 20 57 2020/ 9 20/ II 20/ 13 20/ 15 17 22023 2 19 20/ 21 20/ 25 20/2 27 20I 29 31 20/ 33 20 5 20/ 37 20/ 39 41 20/ 43 20/ 45 20/ * 47 20/ 49 20/ s 51 20/ s 55 2053 / s 61 2059 65 20/ 57 20/ 63 20/ 69 20/ 71 73 20/ 75 20/ 77 20/ 79 20/ 81 20/ 83 20/ SECTION TOTAL CONNECTED LOAD KVA LIGHTS 0.97 LIGHTS 0.43 LIGHTS 0.53 LIGHTS 0.29 LIGHTS 0.77 LIGHTS 0.50 LIGHTS 0.80 LIGHTS 0.90 LIGHTS 0.34 LIGHTS 0.71 LIGHTS 0.60 LIGHTS 0.90 BLOCK HEATER 2.00 0.00 BATT CHARGER 1.00 RECEPTS 0.36 RECEPTS 0.36 DOOR BUZZER 0.20 RECEPTS 0.36 FIRE STROBE 0.20 SMOKE DETECTO 0.12 RECEPTS* 0.54 RECEPTS: 0.54 RECEPTS* RECEPTS* RECEPTS* RECEPTS* RECEPTS RECEPTS RECEPTS RECEPTS RECEPTS RECEPTS RECEPTS REFRIG REFRIG REFRIG REFRIG SPARE SPARE SPARE SPARE 0.54 0.54 0.54 0.54 0,18 0.18 0.18 0.72 0.90 0.90 0.72 1.50 1.50 1.50 1.50 0.00 0.00 0.00 0.00 13.02 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 DEMAND FACTOR 30/3 20% 20/ 20/ 20/ 20 20/ 0/20, 20% 20/ 202020 / 20/ 20/ 20/ 20/ 2520/ 20/ 20/ 0/ 20/ 202020 / 20/ 20/ 20/ 20/ 20 20/ 20/ 20 20/ SURGE PROTECT 0.00 0.00 0.00 FACP .00 ACCESS HE .00 CCTV HE .00 LVR PANEL .00 CLOCK SYSTEM .00 ALERTING PNL .00 AUTO DOOR 0.60 FUEL DISP 1.50 FUEL DISP 1.50 FUEL CONTROL 2.00 0.00 FM200 1.00 RECEPTS 0.36 RECEPTS 0.36 RECEPTS 0.36 RECEPTS 0.36 RECEPTS 0.36 RECEPTS 0.72 RECEPTS 0.72 RECEPTS 0.72 COFFEE MAKER 1.50 SOLENOID/IGN 0.20 RECEPTS 0.18 RECEPTS 0.18 RECEPTS 0.54 RECEPTS 0.54 RECEPTS 0.72 RECEPTS 0.18 RECEPTS 0.i8 HOOD 1.00 DISHWASHER 1.20 RECEPTS 0.18 INSTA HOT 1.50 DISPOSER 1,50 RECEPTS 0.18 SPARE 0.00 SPARE 0.00 SPARE 0.00 SPARE 0.00 DEMAND LOAD KVA AMPS LIGHTS RECEPTACLES HEATING LARGEST MOTOR OTHER MOTORS MISCELLANEOUS KITCH. APPLIANCES 7,73 14.94 0,00 0.00 0.00 29.02 0.00 51.69 25% 00% 00% 25% 00% 00% 65% 9.67 14.94 0.00 0.00 0.00 29.02 0.00 26.83 41,47 0.00 0.00 0.00 80.55 0.00 53.63 148.85 PANEL B LOCATION MOUNTING AIC FED FROM CCT NO. I SECTION VOLTS 208 /120 ELEC ROOM 105 AMPS 225 MLO SURFACE 42,000 GROUND BUS PANEL MDP CCT BRKR PROVIDE SURGE PROTECTOR DESCRIPTION LOAD KVA CCT NO. 3 PHASE, 4 WIRE, WYE CCT DESCRIPTION BRKR LOAD KVA 3 5 7 9 II 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 81 83 85 87 89 91 93 95 15/2 15%2 15%2 15%2 15%2 15%2 15%2 15%2 15%2 I5%2 20/I 15/2 15/2 20%2 40%2 40%2 30%2 30/2 20/I 20/I 20/I 20/I 20/I 50/2 20%1 15/2 20/I 20/1 20/I CONNECTED LOAD KVA IDU-I IDU-2 IDU-3 IDU-4 IDU-5 IDU-6 IDU-7 IDU-8 IDU-9 IDU-10 SPARE HRV-I HRV-2 HVAC CONTROL EV CHARGING EV CHARGING DRYER DRYER WASHER WASHER RECEPTS RECEPTS RECEPTS RANGE GAS SOL PNL HRV-3 SPARE SPARE SPARE 0.07 0.00 0.07 0.00 0.07 0.00 0.07 0.00 0.07 0.00 0.07 0.00 0.07 0.00 0.08 0.00 0.08 0,00 0.69 0.00 0.00 0.75 0.00 0.75 0.00 0.50 0.00 6.24 0.00 6.24 0.00 5.00 0.00 5.00 0.00 1.50 1.50 0.43 0.18 0.18 8.80 0.00 1.00 0.75 0.00 0.00 0.00 0.00 38.82 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 DEMAND FACTOR 30/3 SURGE PROTECT 15/12 15/2 15%2 20%2 15%2 20%1 20/I 20/1 20/I 20/1 20/3 20%2 20%1 20/2 201 20/2 20%2 20I2 20/ 20 20/ 20/ 202020/2 20 20/ 20/ 220 0/ 20/ IOU -II IDU-12 IDU-13 AC-ODU BC -I EF-7 EF-8 RECEPTS RECEPTS DAMPERS EXTRACTOR EUH-I CF-3/CF-4 GATE OPERATOR SPARE GATE OPERATOR BATT CHGR BATT CHGR RECEPTS RECEPTS RECEPTS RECEPTS RECEPTS RECEPTS EUH-I FSD FSD SPARE SPARE SPARE SPARE SPARE 0.00 0.00 0.00 0.47 0.00 0.69 0.00 0.69 0.00 2.50 0.00 0.22 0.00 0.86 0.70 0.36 0.36 0.20 3.82 0.00 0.00 2.00 0.00 0.50 2.25 0.00 0.00 2.25 0.00 1.20 0.00 1.20 0.00 0.18 0.36 0.54 0.36 0.18 0.18 1.50 0.00 0.40 0.80 0.00 0.00 0.00 0.00 0.00 DEMAND LOAD KVA AMPS LIGHTS RECEPTACLES HEATING LARGEST MOTOR OTHER MOTORS MISCELLANEOUS KITCH. APPLIANCES 0.00 3.06 3.50 0.00 15.57 42.80 0.00 64.93 25% 00% 00% 25% 00% 00% 65% PANEL M I SECTION VOLTS 208 /120 LOCATION MECH 133 AMPS 400 MLO MOUNTING SURFACE AIC 22,000 FED FROM PANEL MDP CCT NO. CCT BRKR DESCRIPTION 0.00 3.06 3.50 0.00 15.57 42.80 0.00 0.00 8.49 9.72 0.00 43.22 118.80 0.00 64.93 180.23 3 PHASE, 4 WIRE, WYE GROUND BUS PROVIDE SURGE PROTECTOR NOTE: *-DENOTES GFCI TYPE BREAKER LOAD I CCT CCT DESCRIPTION KVA NO. BRKR LOAD KVA 3 5 7 9 II 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 81 83 85 87 89 91 93 95 97 99 101 103 105 107 20 20/ 20/ 20/ 20 20/ 20/ 20/ 20 20/2 20%2 20%2 20%2 20%2 20%2 20% 20/ 25 20/ 20/ 20 20/ 25/ 202020 / 20/ 20/ 20/ 20/ 25/ 25/ 25 25/ 20/2 20%3 20/13 20% 20 20/ 20/ 20 20/ CONNECTED LOAD KVA CF-I/CF-2 UH-2 UH-3 DAMPERS RECEPTS RECEPTS RECEPTS RECEPTS RECEPTS EUH-I EUH-2 EUH-3 EUH-4 EUH-5 EUH-6 RECEPTS CO & NO2 EF-9 EF-2 EF-3 EF-5 EF-4 EF-I SPARE RECEPTS RECEPTS REFRIG RECEPTS RECEPTS RECEPTS GARAGE DOOR GARAGE DOOR GARAGE DOOR GARAGE DOOR PART WASHER FOUR -FOLD DR FOUR -FOLD DR SPARE SPARE SPARE SPARE SPARE SPARE 0.50 0.55 0.55 0.20 0.18 0.54 0.36 0.36 0.36 2.00 0.00 2.00 0.00 2.00 0.00 1.00 0.00 2.40 0.00 1.50 0.00 0.72 0.20 1.66 0.60 0.10 0.20 0.40 0.30 0.00 0.72 0.72 0.50 0.36 0.18 0.36 1.66 1.66 1.66 1.66 2.00 0.00 2.34 0.00 0.00 2.34 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 15.66 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 DEMAND FACTOR 30/3 SURGE PROTECT 20/I* REC-DROP CORD 30/Is REC-DROP CORD 30/I* REC-DROP CORD 30/Is REC-DROP CORD 30/Is REC-DROP CORD 20/Is REC-DROP CORD 20/3 EF-6 30/3 VEF 20/I CONTROL PNL 20/I SPARE 20/2 BENCH HOOD 20% SPARE 20/ RECEPTS 20/ RECEPTS 20/ RECEPTS 20/ RECEPTS 20/ RECEPTS 20/ RECEPTS 20/2 MAGNA-RAIL 20%2 MAGNA-RAIL 20%3 COMP-2 30/3 COMP-1 20/I DHWH-I 20/I DHWH-2 20/1 DHWCP 20/I MAP (FUT) 201 RECEPTS 20/I RECEPTS 20/2 EUH-I 20/ SPARE 20/ SPARE 20/ SPARE 20/ SPARE 20/ SPARE 20/ SPARE 20/ SPARE 20/ SPARE 20/ SPARE 20/ SPARE 0.00 0.00 0.00 .00 .50 .50 .50 .50 .00 .26 0.00 0.00 8.71 0.00 0.00 1.00 0.00 1.16 0.00 0.00 0.36 0.36 0.36 0.36 0.90 0.72 1.00 0.00 1.00 0.00 2.70 0.00 0.00 6.01 0.00 0.00 0.60 0.60 0.70 0.50 0.36 0.36 2.00 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 DEMAND LOAD KVA AMPS LIGHTS RECEPTACLES HEATING LARGEST MOTOR OTHER MOTORS MISCELLANEOUS KITCH. APPLIANCES 0.00 8.64 14.00 8.71 25.25 17.26 0.00 73.86 25% 00% 00% 25% 00% 00% 65% 0.00 8.64 14.00 10.89 25.25 17.26 0.00 0.00 23.98 38.86 30.22 70.09 47.91 0.00 76.04 211.06 ITZMAURICE &ASSOCWES Iaoow.as.Av. R. So s.MO. Ira rmeas.ru 12049'5.12 . 3 4/5/19 Addendum 9 18 12/11/18 Design Revisions 1A 12/11/18 Permit Corrections #1 Rev Date Issue Tukwila Fire Station 51 Project No. Designed by Drawn by Checked by 17001 RJ AS,KH,KU KW Weinstein A+U Architects + Urban Designers, LLC 2200 Western Ave Seattle, WA 98121 T 206 443 8606 F 206 4431218 www.weinsteinau.com 02018 Weinstein Mil • These documents have been prepared specifically for the above named project They am not suitable for use on other projects or in other locations without the approval and participation of the Arch ted. flF\/Ir_A C- FOri QC)rot?-. 1ANCE ItIri ;;:! i 2019 r::t1 or "ukv.;Y. L 1:11.0;NC; 111V'^ION JURISDICTIONAL APPROVAL STAMP Issue Date REVISED BID SET 1/17/19 ARCHITECTS + URBAN DESIGNERS ELi 9-0516 Cr>'Y '37 Sheet Title PANEL SCHEDULES Sheet E801