Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL19-0529 - JOLLIBEE - ADDED EQUIPMENT, OUTLETS, CIRCUITS, LIGHT FIXTURES AND RELOCATED ELECTRICAL PANELS
JOLLIBEE 1372 SOUTHCENTER MALL ELI 9-0529 Parcel No: Address: City of Tukwila ent of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: httn://www/.TuhwUaVVA.Rox ELECTRICAL PERMIT 9202470090 Permit Number: EL19-0529 1372 SOUTHCENTER MALL Project Name: JOLLIBEE Issue Date: 12/17/2019 Permit Expires On: 6/14/2820 Owner: Name: Address: Contact Person: Name: WESTFIELD PROPERTY TAX DEPT POBOX l3O94O'[ARLSDAD'CA, 92013 LIZETTE GUITERREZ Address: 1000 CORPORATE CENTER DR SUITE 500 MONTEREY PARK, CA, 91754 Contractor: Name: GREAT WALL ELECTRIC INC Address: POBOX 38]8,SEATTLE, WA, S8l24 License No: GREATWE954CG Lender: Name: Address: Phone: (626) 288-6898 Phone: (206) 898-9168 Expiration Date: 2/7/I021 DESCRIPTION OF WORK: NEW ADDED EQUIPMENT, OUTLETSCIRCUITS, LIGHT FIXTURES AND RELOCATED ELECTRICAL PANELS. Valuation ef single family: $0.08 Valuatiori of mf/comm: $25'080.00 Type o[Work: TENANT IMP Fees Collected: $729A2 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International ResidentaI Code Edition: International Mechanical Code Editiori: Uniform Plumbing Code Edition: International FueI Gas Code: Permit Center Authorized Signatu 2015 20152015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Da 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or Iocal laws regula ing construction or the performance of work. I am authorized to sign and obtain this development permd gree to the conditions attached to this permit. Signature: - � ' Date ~�7� - - _ Print N���` --7� �U C This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector ateach work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accoroncewithNFPA7O-mBC,andrequirememsfove|ectrica|)nsmUations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2V6)43O'935V 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB 0 City of Tukwila ~� �___--°'�r.�'�~~~�.~° �� y� w�p�'nn*/� wxr `mn,xpn'�� ��vc/up'/'cx,^ u t B , `.`.u. Washington 98188 .°"�.~`~"=.�=.�"^"" Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: 9202470090 1372 SOUTHCENTER MALL Project Name: JOLLIBEE ELECTRICAL PERMIT Permit Number: EL19-0529 Issue Date: 12/17/2019 Permit Expires On: 6/14/2020 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: WESTFIELD PROPERTY TAX DEPT POBOX 13U94O,[ARLS8AD,CA, 92013 LIZETTE GUITERREZ 1000 CORPORATE CENTER DR SUITE 500 , MONTEREY PARK, CA, 91754 CORE CONSTRU wNLL[ 8435 47T ^VE5'SEATTLE, WA, 98118- 22 CO [CL92/18 1 Phone: (626) 288-6898 Phone: (206) 883-3037 Expiration Date: 5/3/2021 DESCRIPTION OF WORK: NEW ADDED EQUIPMENTOUTLETS, CIRCUITS, UGHT FIXTURES AND RELOCATED ELECTRtCAL PANELS. Valuation of single family: $O.00 Valuation of mf/comm: $25,000.00 Type of Work: TENANT IMP Fees Collected: $729.42 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Buliding Code Edition: International Residentia Code Edition: lnternational Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 20152017 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signatur /" Date: / //7 l'f T; Q 7` Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. _OA-oqlm Project No. Date Application Accepted: V) Date Application Expires: or oizce use onl ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 1971"1/ King Co Assessor's Tax No.: Site Address: 97SOUTHCENTER MALL TUKWILA, WA 98188 Suite Number: 368 Floor: LEVEL 1 Tenant Name: JOLLIBEE New Tenant: EJ Yes ..No PROPERTY OWNER Name: EMILY YEE Address: 4905 OLD ORCHARD CENTER STE. 060 City: SKOKIE State: i L Zip: 60077 CONTACT PERSON — person receiving all project communication Name: LIZETTE GUTIERREZ Address: 1000 CORPORATE CENTER DRIVE SUITE 550 City: MONTEREY PARK State: CA Zip:9754 Phone: 626-288-6898 Fax: Email: lizette@garywang.com ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 12°11.66 2CK Scope of Work (please provide detailed information): NEW ADDED EQUIPMENT, OUTLETS, CIRCUITS, LIGHT FIXTURES AND RELOCATED ELECTRICAL PANELS. Will service be altered? 0 Yes 0 No Adding more than 50 amps? [:: Yes 0 No Type of Use: COMMERCIAL RESTAURANT Type of work: O New 0 Addition 0 Service Change O Low Voltage 0 Generator 0 Fire Alarm Property Served by: O Puget Sound Energy 0 Seattle City Light WAPermit Center \ Applications-HandoutsTermit Applications \ PDF'alectrical Permit Application Revised 1-17-1 9.docx 0 Remodel 0 Telecommunication 12 Tenant Improvement 0 Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ED New single family dwellings $180.00 (including an attached garage) o Garages, pools, spas and outbuildings $120.00 ea o Low voltage systems (alarm)._ .$60.00 ea RESIDENTIAL REMODEL ANI) SERVICE CHANGES El Service change or alteration $120.00 (no added/altered circuits) o Service change with added/altered circuits $100.00 number of added circuits $10.00 ea o Circuits added/altered without service change $60,00 (up to 5 circuits) 1p Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea El Meter/mast repair ........................ .......... ..... . ..... El Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $60.00 O Temporary service (generator) $90.00 O Manufactured/mobile home service $100.00 (excluding garage or outbuilding) ID Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: /11 Print Name: Lc -4 0 Day Telephone: &2.(o).2c5(9" (03 s5 City 000 Pb Th CXTOVU71- 121 .5u ro -t14/tvoinzel r re-fe. 60- Mailing Address: WAPermit Center \Applications-Handouts\Permit ApplientionAPDFatElectrical Permit Application Revised 1 -1 7- 19. docx State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK 7210'' EL19-0529 Address: 1372 SOUTHCENTER M x1,::9202470090 72 Credit Card Fee 2.10 Credit Card Fee R000.369.908.00.00 0.00 2.10 ELECTRICAL; , $70.00 ADDITIONAL PLAN REVIEW R000.345.830.00.00 0.00 $ 70.00 TOTAL FEES PAID BY RECEIPT: R20807 $72.10 Date Paid: Thursday, May 21, 2020 Paid By: ANGEL NG FUNG Pay Method: CREDIT CARD 08153G Printed: Thursday, May 21, 2020 9:46 AM 1 of 1 CO5/21/2020 TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 286'433'1870 CITY OF TUKWILA 0017340000802374464500 Date: 05/21/2020 09:46:05 AM VISA CARD NUMBER: CREDIT CARD SALE *****~*+*8317 K TOTAL AMOUNT: $72.10 APPROVAL CD: 08153G RECORD #: 000 CLERK ID: Elisa X I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy 1m Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $4,574.87 D19-0207 Address: 1372 SOUTHCENTER MALL Apn: 9202470090 $2,753.58 Credit Card Fee $80.20 Credit Card Fee I R000.369.908.00.00 0.00 $80.20 DEVELOPMENT $2,587.62 PERMIT FEE R000.322.100.00.00 0.00 $1,715.23 PLAN CHECK FEE R000.345.830.00.00 0.00 $847.39 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $85.76 TECHNOLOGY FEE R000.322.900.04.00 0.00 $85.76 EL19-0529 Address: 1372 SOUTHCENTER MALL Apn: 9202470090 $585.58 Credit Card Fee $17.06 Credit Card Fee R000.369.908.00.00 1 0.00 I $17.06 ELECTRICAL $541.12 PERMIT FEE MULTI-FAM/COMM I R000.322.101.00.00 1 0.00 1' $541.12 TECHNOLOGY FEE $27.40 TECHNOLOGY FEE 1 R000.322.900.04.00 1 0.00 $27.40 M19-0103 Address: 1372 SOUTHCENTER MALL Apn: 9202470090 $786.67 Credit Card Fee $22.91 Credit Card Fee R000.369.908.00.00 0.00 $22.91 MECHANICAL $730.54 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $631.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $66.11 TECHNOLOGY FEE $33.22 TECHNOLOGY FEE 8000.322.900.04.00 0.00 $33.22 PG19-0086 Address: 1372 SOUTHCENTER MALL Apn: 9202470090 $449.04 Credit Card Fee $13.08 Credit Card Fee R000.369.908.00.00 0.00 $13.08 GAS $208.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PERMIT FEE R000.322.100.00.00 0.00 $143.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $30.66 Date Paid: Tuesday, December 17, 2019 Paid By: ANGEL NG FUNG Pay Method: CREDIT CARD 00092G Printed: Tuesday, December 17, 2019 2:31 PM 1 of 2 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK PAID $4,574.87 PG19-0086 Address: 1372 SOUTHCENTER MALL Apn: 9202470090. $449.04 PLUMBING $208.00 R000.322.100.00.00 0.00 $173.00 PERMIT ISSUANCE BASE FEE R000:322.100.00.00 0.00 $35.00 TECHNOLOGY FEE $19.30 TECHNOLOGY FEE R000,322.900.04.00 0.00 TOTAL FEES;:PAID BY RECEIPT: R19328 $19.30 $4,574.87 Date Paid: Tuesday, December 17, 2019 Paid By: ANGEL NG FUNG Pay Method: CREDIT CARD 00092G Printed: Tuesday, December 17, 2019 2:31 PM 2 of 2 YSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433'1870 CITY OF TUKWILA 0017]49000802]74464500 Date: 12/17/2019 82:30:02 PM CREDIT CARD SALE VISA CARD NUMBER: *********+8317 K TRAN AMOUNT: $4'574.07 APPROVAL CD: 00092G RECORD #: 000 CLERK ID: frankie X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT Thank you! Merchant Copy Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $143.84 EL19-0529 Address: 1372 SOUTHCENTER MALL Apn: 9202470090, 43.84 ELECTRICAL 43.84 PERMIT FEE MULTI-FAM/COMM PLAN CHECK FEE R000,322.101.00.00 R000.345.832.00.00 0.00 6.85 0,00 $136.99 TOTAL FEES PAID BY RECEIPT: R17966 $143.84 Date Paid: Friday, June 21, 2019 Paid By: GARY WANG & ASSOCIATES Pay Method: CHECK 16252 Printed: Friday, June 21, 2019 10:33 AM 1 of 1. SYSTEM5 INSPECTION RECORD Retain a copy with permit NSPECT0N NO. PRMJT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit Inspection Request Line (206) 43935O Project:. o nspe t Address: /372, ate Called: Special n tructions: DateWanted: a.m. . • Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. nsp cto REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit Inspection Request Line (206) 438-9350 Pt: �' Type o l s `Date Called: cti Address: 7 � ��� '" Special instructio s: ( 362 0 - , _ Tate Waned: a.m. p.m. Requester: 77 4r Phone No: 6 2? Coe Approved per applicable codes. D Corrections required prior to approval. COMMENTS: nspec 'tor: Date: REINSPECTIQM FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 11/1/2019 City of Tukwila Allan Ekberg, Mayor Department of Community Development LIZETTE GUITERREZ 1000 CORPORATE CENTER DR SUITE 500 MONTEREY PARK, CA 91754 RE: Permit Application No. EL 19-0529 JOLLIBEE 1372 SOUTHCENTER MALL Dear LIZETTE GUITERREZ, Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 6/21/2019, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 12/21/2019. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: ELI9-0529 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 July 19, 2019 City of Tukwila Department of Community Development LIZETTE GUITERREZ 1000 CORPORATE CENTER DR SUITE 500 MONTEREY PARK, CA 91754 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL19-0529 JOLLIBEE - 1372 SOUTHCENTER MALL Dear LIZETTE GUITERREZ, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. CORRECTION/ #1 1). SHEET E-100 REVISE PANEL B FEEDER CONDUIT TO (2) 2"C. WITH (N) 4 #3/0 & 1 #3 GND. PRESENTLY INDICATES 1 CONDUIT AND #6 GND. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. To better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, 6-04- Kandace Nichols Permit Technician File No, EL19-0529 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 o POINT COORD COPP PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0529 DATE: 03/31/2020 PROJECT NAME: JOLLIBEE SITE ADDRESS: 1372 SOUTHCENTER MALL Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision #. L after Permit Issued DEPARTMENTS: Building Division Public Works ..•••••••••• Fire Prevention Structural P Planning Division E Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 04/02/20 Structural Review Required DATE: P APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: Approved with Conditions Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: 05/28/20 Fire Fees Apply DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire D Ping 0 PW 0 Staff Initials: 12118/2013 CPERMIT COORD COPY C) PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL 1 9-0529 DATE: 09/06/19 PROJECT NAME: JOLLIBEE SITE ADDRESS: 1372 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: AU/ Btu ding Division Public Works r1 Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable El (no approval/review required) Planning Division Permit Coordinator n DATE: 09/10/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n DUE DATE: 10/01/2019 Approved with Conditions " Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: LI REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY `P•w PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0529 DATE: C16/21/19 PROJECT NAME: JOLLIBEE SITE ADDRESS: 1372 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 110 g?ldinCgasion Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/25/19 Structural Review Required REVIEWER'S T ALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/23/19 Approved Approved with Conditions n Corrections Required Denied (corrections entered in Reviews)(ie: Zoning Issues Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg J Fire 0 Ping 0 PW LJ Staff Initials: 12/18/2013 PROJECT NAME: Nib\ VINi& PERMIT NO: Et.H— SITE ADDRESS: 01/• SOW#ICAnter \ ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 CV Summary of Revision: -ez0 & \ Received by: Received by: C0d tit - l cl REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) Date: 08/09/19 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www,TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: EL19-0529 O Response to Incomplete Letter # O Response to Correction Letter # 1 O Revision # after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner O Deferred Submittal # Project Name: Jollibee Project Address: 1372 Southcenter Mall Contact Person: Lizette Gutierrez RECEIVED CITY OF TUKWILA SEP n 5 2019 PERMIT CENTER ( Phone Number: 626)288-6898 Summary of Revision: 1) SHEET E-100 REVISE PANEL B FEEDER CONDUIT TO (2) 2"C. WITH (N) 4 #3/0 & 1 #3 GND. PRESENTLY INDICATES 1 CONDUIT AND #6 GND. RESPONSE: PLEASE SEE -101 II "i a Sheet Number(s): "Cloud" or highlight all areas of revision including Received at the City of Tukwila Pe iit Center by: Entered in TRAKiT on WAPermit Center (Rachelle)1Kandace - Revision Submittal Form doe Revised: August 2015 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. 3/26/2020 EL -19-0529 Date: Plan Checic/Permit Number: O Response to Incomplete Letter # O Response to Correction Letter # EN Revision # 1 after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner O Deferred Submittal # Project Name: Jollibee Project Address: 1372 Southcenter Mall Grachel Cornellio 626-221-5638 Contact Person: Phone Number: Summary of Revision: Email: Grachel@garywang.com Electrical upgrade revision to single line diagram. See attached plans, changes are indicated in area. Sheet Number(s): E100, E200, E300, E301, E400, E500, E600, E700, E800 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on '3 -3( -a0 WAPermit Center \ TemplatestFormalRevision Submittal Form.doc Revised: August 2015 0 Some online services are currently unavailable. See a list of service outages. chttos://ini.wa.ciov/aaencv/system-statusl 214, V1,11.1,01N, kj Labor & Industries (https://lni.wa.govl GREAT WALL ELECTRIC INC Owner or tradesperson Principals LEE, YOUNG, PRESIDENT LEE, YOUNG, AGENT KEHLE, RON, AGENT (End: 03/07/2005) Doing business as GREAT WALL ELECTRIC INC WA UBI No. 602 434 633 PO BOX 3838 SEATTLE, WA 98124 206-898-9168 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active Meets current requirements. License specialties GENERAL License no. GREATWE954CG Effective — expiration 02/07/2005— 02/07/2021 Designated administrator LEE, YOUNG KONG License type Electrical Administrator Bond, CBIC Bond account no. SF9723 Active Meets current requirements. License no. LEE**YK973CR $4,000 00 Received by L&I Effective date 03/26/2005 03/24/2005 Expiration date Until Canceled §PYIP9§. No savings accounts during the previous 6 year period. License Violations Infraction no. EALRD00298 Issue date RCW/WAC 03/30/2017 19.28.271 RCW Violation city Violation amount SEATTLE $250.00 Type of violation ELECTRICAL CITATION Description Employing an individual for the purposes of chapter 19.28 RCW who does not possess a valid certificate of competency or training certificate to do electrical work, TAN, JIAN QUN an expired ET (TAN*JJQ976RS) Certifications & Endorsemen))..-- OMWBE Certifications No active certifications exist for this buness, Apprentice Training, Agent No active Washington registered apprentices exist for this business. Washington allows the use of apprentices registered with Oregon or Montana. Contact the Oregon Bureau of Labor & Industries or Montana Department of Labor & Industry to verify if this business has apprentices. Workers' Comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. Account is current. L&I Account ID 017,710-01 Doing business as GREAT WALL ELECTRIC INC Estimated workers reported Quarter 4 of Year 2019 "1 to 3 Workers" L&I account contact T3 / NICHOLE CAROW (360)902-5634 - Email: CANI235@lni.wa.gov Public Works Requirements Verify the contractor is eligible to perform work on publlic works projects. Required Training— Effective July 1, 2019 Needs to complete training, Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace Safety & Health Check for any past safety and health violations found on jobsites this business was responsible for. No inspections during the previous 6 year period. GENERAL NOTES LEGEND AND NOTES LIGHTING FIXTURE SCHEDULE 1. BEFORE SUBMITTING BID THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FULLY ACQUAINT HIMSELF WITH THE JOB CONDITION, SERVICE REQUIREMENTS BY UTILITY COMPANY AND CONNECTIONS, AND OTHER CONDITIONS INCLUDING TRANSFORMER PAD, ALL NECESSARY PULL BOXES, JUNCTION BOXES, SIZE AND NUMBER OF CONDUITS AND CONDUCTORS, CONDUIT FITTINGS, SERVICE COMPONENTS, PANELBOARDS, ETC., WHETHER . SHOWN ON DRAWINGS OR NOT, TO MAKE A COMPLETE AND OPERABLE ELECTRICAL SYSTEM WITHOUT ADDITIONAL COST TO OWNER. 2. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL LOCAL LAWS, RULES AND REGULATIONS OF ALL LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION. IN CASE OF CONFLICT BETWEEN REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY. FOLLOW THE LOCAL LAWS, RULES AND REGULATIONS FOR ANY CONFLICTS BETWEEN THE CONTRACT DRAWINGS AND THE LAWS, RULES AND REGULATION. 3. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND ARRANGE ALL REQUIRED INSPECTIONS FOR THE EXECUTION OF THE WORK UNDER THIS CONTRACT. HE SHALL FURNISH ALL INSTRUMENTS AND PERFORM ALL TESTS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. HE SHALL ALSO CORRECT ALL FAILURES AND REPLACE ANY DAMAGED PORTIONS OF THE WORK RESULTING FROM THESE TESTS. THE COST OF THE FOREGOING ITEMS SHALL BE PAID BY THE CONTRACTOR. 4. THE CONTRACTOR SHALL COORDINATE CLOSELY WITH THE OWNER AND OTHER TRADES FOR ALL PHASES AND SCHEDULING OF WORK, AND AUTHORIZED IN WRITING BY THE OWNER AT LEAST ONE WEEK PRIOR TO THE EXECUTION OF ANY WORK. 5. ALL MATERIAL FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE NEW AND UL LISTED, FREE FROM ALL DEFECTS, AND SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE OF THE WORK. 6. THE ELECTRICAL DRAWINGS. CONDUIT RUNS, WIRING AND ELECTRICAL INFORMATION ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE THE LOCATION OF EQUIPMENT OR OUTLETS. 7. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS OF ALL LIGHTING FIXTURES, CEILING MOUNTED OUTLETS AND EQUIPMENT. 8. ALL RECEPTACLES AND OUTLET MOUNTING HEIGHTS AND EXACT LOCATION SHALL BE COORDINATED WITH ARCHITECTURAL, DRAWINGS ELEVATIONS PRIOR TO ROUGH -IN WORK. 9. FT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY TYPES OF CEILING SYSTEMS AND TO FURNISH APPROVED LIGHTING FIXTURES OF THE TYPE REQUIRED FOR MOUNTING IN RELATED CEILINGS. FIXTURES SHALL BE COMPLETE WITH NECESSARY MOUNTING HARDWARE AND ACCESSORIES. FIXTURES LOCATED IN DAMP OR WET LOCATIONS SHALL BE LABELED FOR USE IN SUCH LOCATIONS. 10. ALL RECESSED LIGHTING FIXTURES, SPEAKERS, PANELBOARDS, SWITCHES, ETC., MOUNTED IN FIRE RATED STRUCTURES SHALL BE ENCLOSED WITH AN APPROVED ENCLOSURE CARRYING THE SAME FIRE RATING AS THE STRUCTURE. 11. ELECTRICAL OUTLETS ON OPPOSITE SIDES OF FIRE RATED WALLS AND PARTITIONS MUST BE SEPARATED BY DISTANCE OF 24 INCHES HORIZONTAL U.B.C. 4304 OPENINGS IN FIRE RATED WALLS GREATER THAN 16 SQ. INCHES MUST BE FIRE STOPPED. 12. SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS, CEILINGS, FLOORS, ETC., TO MAINTAIN THE FIRE RATING. FURNISH AND INSTALL FIRE RATED ENCLOSURE FOR ALL EQUIPMENT PENETRATING INTO FIRE RATED ENVELOPES, SPACES ETC. 13. PORTIONS OF THE CEILING SYSTEMS MAY BE INACCESSIBLE. THEREFORE, THE CONTRACTOR SHALL STRATEGICALLY LOCATE ACCESS BOXES, ETC., WHICH SHALL BE READILY ACCESSIBLE. ALL LIGHTING FIXTURE WIRING, BALLASTS, J-BOXES, ETC. SHALL BE ACCESSIBLE FROM FIXTURE OPENING. 14. ALL WIRING AND ELECTRICAL EQUIPMENT INSTALLED FOR MECHANICAL AND PLUMBING EQUIPMENT SHALL BE IN ACCORDANCE WITH DIVISION 15 AND ASSOCIATED DRAWINGS. CONTRACTOR TO OBTAIN THE REQUIRED MECHANICAL AND PLUMBING DRAWINGS AND PROVIDE ALL EQUIPMENT, RACEWAYS, WIRING, ETC., AS INDICATED THEREON AS PROVIDED UNDER THE ELECTRICAL WORK. 15. ALL FINAL CONNECTIONS TO OWNER FURNISHED EQUIPMENT SHALL BE MADE BY THE CONTRACTOR UNLESS OTHERWISE NOTED. VERIFY ELECTRICAL CHARACTERISTICS AND U.L. LISTING PRIOR TO CONNECTION. 16. THE CONTRACTOR SHALL VERIFY THE LOAD INPUT VOLTAGE OF ALL EQUIPMENT PRIOR TO INSTALLATION. ACCEPTING ANY EQUIPMENT RESULT IN LOAD INCREASE SHALL BE THE RESPONSIBILITY OF CONTRACTOR. 17. PROVIDE AN ADDITIONAL JUNCTION BOX [SIZE AS REQUIRED) WHERE THE NUMBER OF CONDUCTORS EXCEEDS THE MAXIMUM ALLOWED FOR A GIVEN JUNCTION POINT OR OUTLET. 18. CONDUCTORS SHALL BE THHN/THWN 600 VOLT INSULATION COPPER UNLESS OTHERWISE NOTED. USE PROPER TEMPERATURE RATING OF CONDUCTORS BASED ON THE AMBIENT AIR TEMPERATURE WHERE CONDUCTORS ARE BEING USED. HIGHER AMPACITY CONDUCTORS AND LARGER RACEWAY SHALL BE PROVIDED TO OFFSET THE AMPACITY CORRECTION FACTORS AS INDICATED IN NEC TABLE 310 AND ELSEWHERE IN CODE. 19. DO ALL DRILLING, CUTTING, CHANNELING AND PATCHING REQUIRE TO ELECTRICAL WORK AND INDICATED OR HEREIN SPECIFIED. ALL HOLES, CURBS, ETC., IN FLOORS, CEILINGS AND WALLS SHALL BE PATCHED, UNLESS INDICATED OTHERWISE. PAINT ALL EXPOSED ELECTRICAL RACEWAYS, CABINETS, ENCLOSURES AND FITTINGS TO MATCH IN COLOR ADJACENT SURFACES IN FINISHED AREAS. 20. EMERGENCY LIGHTING SHALL BE PROVIDED PER U.B.C. OR LOCAL CODE AND SHALL BE DESIGN TO PROVIDE MINIMUM REQUIRE FOOTCANDLES AND LUMENS. 21. BRANCH CONTROL CIRCUITING MAY NOT BE INDICATED ON THESE PLANS. CONTRACTOR IS RESPONSIBLE TO COMPLETE THE BRANCH CIRCUIT WIRING IN ACCORDANCE WITH PLAN NOTES AND AS PERMITTED BY 2014 NATIONAL ELECTRICAL CODE (N.E.C.) AND ANY LOCAL SUPPLEMENT. CONTRACTOR SHALL SUBMIT FINISH DRAWINGS AS A PART OF SHOP DRAWING SUBMITTAL TO ARCHITECT AND AUTHORITY HAVING JURISDICTION. 22. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND SUBMITTALS FOR ELECTRICAL EQUIPMENT SHOWN ON THE PLANS AND SPECIFICATION FOR THE ENGINEERS APPROVAL. THE ENGINEER MAY REQUIRE THE CONTRACTOR TO REDO ANY WORK, WHICH WAS NOT APPROVED, OR THE ENGINEER MAY REQUIRE A CREDIT TO THE OWNER. PROVIDE A SET OF AS BUILTS AFTER THE JOB S COMPLETED. THIS SET SHALL BE CONTINUOUSLY UPDATED DURING CONSTRUCTION PERIOD. e Sa $1 4) Sm e Q WALL MOUNTED OCCUPANCY SENSOR. SINGLE POLE TOGGLE SWITCH 20 AMP, 120 V, 0 44" AFF DOUBLE POLE TOGGLE SWITCH 20 AMP, 120 V, @ 44" AFF THREE WAYSWITCH2OAMP, 120V, @44"AFF DIMMER SWITCH I B00 WATTS, 15 AMP MINIMUM, 120 V, ®44" AFF MOTOR RATED SWITCH, HP RATED SINGLE RECEPTACLE, NEMA RATING AS NOTED DUPLEX RECEPTACLE 20 AMP, 120 V GROUNDING TYPE, @ 15" AFF CONTROLLED DUPLEX RECEPTACLE 20 AMP, 120 V GROUNDING TYPE, 1915" AFF DUPLEX RECEPTACLE 20 AMP 120V GROUNDING TYPE, ® CEILING DOUBLE DUPLEX RECEPTACLE 20 AMP 120V GROUNDING TYPE, @ 15" AFF DUPLEX RECEPTACLE 20 AMP 120V GROUNDING TYPE. FLOOR MOUNTED GFCI RECEPTACLE, 20 AMP 120V GROUNDING TYPE, 0 42' AFF, U.N.O. DEDICATED RECEPTACLE, 208V, 30 TELEPHONE OUTLET WITH 3/4" CONDUIT TO TELEPHONE BACKBOARD TEL. OUTLET & DATA OUTLET WITH (2) 3/4" CONDUIT DMA OUTLET WITH 3/4" CONDUIT. JUNCTION BOX TO SUIT THE FIELD CONDITIONS MOTOR OUTLET NOTES: 1. SUBSCRIPT LETTER NEXT TO THE ABOVE SYMBOLS INDICATES DEVICE CONTROLLED 2. DEVICES AND COVER PLATE COLOR AS SELECTED BY ARCHITECT, SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF OUTLET, UNLESS NOTED. COORDINATE REFRIGERATION OUTLET REQUIREMENT WITH HILLS REFRIGERATION PLAN. 3. RECEPTACLES IN BATHROOM, LAUNDRY ROOM, AND KITCHEN SINK AND EXTERIOR LOCATIONS SHALL BE GROUND FAULT TYPE (GFI) EMERGENCY CIRCUIT. LOCK ON DEVICE FOR BREAKER SERVING CIRCUIT BREAKER -` o- SWITCH AND FUSES 0-I DISCONNECT SWITCH I� COMBINATION MAGNETIC STARTER & FUSED DISCONNECT m MANUAL MOTOR STARTER 3-P, W / OVER LOAD PRETECTION QM WATT/HOUR METER SOCKET ® SMOKE DETECTOR TRANSFORMER m PAD MOUNTED TRANSFORMER U CURRENT TRANSFORMER TLC SWITCHBOARD PANELBOARD ® TELEPHONE CABINET WITH BACKBOARD NOTES: 1. BREAKERS, SWITCHES, FUSES, METER SOCKETS, AND CURRENT CARRYING DEVICES SHALL BE DESIGNED TO WITHSTAND MAXIMUM AVAILABLE FAULT CURRENT (AFC( ESTABLISHED BY SERVING UTILITY 2. SWITCHBOARDS AND PANELBOARDS.BUSSING SHALL BE BRACED TO WITH- STAND MAXIMUM AVAILABLE FAULT A-1,3,5 > CONDUIT HOME RUN TO SOURCE INDICATING PANEL "A" CIRCUITS #1, 3 & 5 VIt #10 -T - CONDUIT RUN CONCEALED IN CEILING SPACE OR IN WALL CONDUIT RUN BELOW FLOORS OR IN GRADE HASH MARKS INDICATE QUANTITY OF CONDUCTORS. NO HASH MARK INDICATES 2 #12 AWG. U.O.N. (#10INDICATES #10 AWG. CONDUCTORS) SIZE OF CONDUIT SHALL BE BASED ON TABLE I, CHAPTER 9 OF N.E.C. AMD TABLE 3A AND 3B SHALL DETERMINE THE CONDUIT SIZES. MINIMUM CONDUIT SIZE SHALL BE 1 /2". TELEPHONE CABLE IN 3/4" CONDUIT -TV- TELEVISION ANTENNA CABLE IN 3/4" CONDUIT - S - CONDUIT RUN FOR SPEAKER SYSTEM. 3/4" C. U.O.N. - F- CONDUIT RUN FOR FIRE ALARM SYSTEM. 3/4" C. U.O.N. D. NOTES: 1. TELEPHONE AND TELEVISION CABLES MAY BE PREWIRED BY LOCAL TEL/COMM/CABLE T.V. COMPANY. 2. ALL CONDUIT SHALL BE RIGID STEEL OR EMT. FLEXIBLE CONDUIT SHALL BE LIMITED TO 72" FOR FINAL CONNECTION TO LIGHTING FIXTURES OR MOTORS, INCLUDE GROUNDING CONDUCTOR. P.V.C. CONDUIT SHALL BE USED ONLY FOR UNDERGROUND. SHEET INDEX SHEET # SHEET NAME E-100 GENERAL NOTES, SINGLE LINE DIAGRAM E-200 SITE ELECTRICAL PLAN E300 POWER PLAN E-301 KITCHEN EQUIPMENT SCHEDULE E-400 LIGHTING PLAN E-500 ELECTRICAL ROOF PLAN E-600 PANEL SCHEDULE E-700 ELECTRICAL DETAILS E-800 INTERIOR LIGHTING COMPLIANCE LEGEND FIXTURE TYPE LAMPS 2TW TYPE INPUT WATTAGE VOLTAGE BALLAST DESCRIPTION FINISH MOUNTING LOCATION REMARKS A / AE LED 42 UNI LED DRIVER 2' X 4' RECESSED MOUNTED TROFFER LED LIGHT COMMERCIAL LIGHTING INDUSTIES: FOR A TYPE: CLI-NAJOLA FOR AE TYPE CLI-NAJOLAE RECESSED INDOOR 0-10V DIIMMING/ 90 MINUTES BATTERY BACK UP B/BE X LED LED 25 4.5 UNI 120 / 277 LED DRIVER 2' X 2' RECESSED MOUNTED TROFFER LED LIGHT COMMERCIAL LIGHTING INDUSTIES: FOR B TYPE: CLI-NAJOLB FOR BE TYPE :NAJOLBE UNIVERSAL MOUNTED EXIT SIGN COMMERCIAL LIGHTING INDUSTRIES: CLI-NAJOLEXIT ANODIZED ALUMINUM RECESSED WALL INDOOR INDOOR 0-I0V DIIMMING/ 90 MINUTES BATTERY BACK UP 90 MINUTES BATTERY BACK UP / • M (E) 200A 3 (E) 2"C, 4 #3/0 & 1 #6 GND I f (E) PANEL A i L - - -J (E) MAIN DISTRIBUTION BOARD "MS" (E) 1200A, 120/208V, 34), 4W BUS 42KAIC • • • M (E) 200A 3 / (E) 2"C, 4 #3/0 & 1 #6 GND r----1 i 1 4E) PANEL L---J SINGLE LINE NOTES: 1. ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO ORDERING NEW EQUIPMENT/DEVICES. 2. ELECTRICAL CONTRACTOR / OWNER TO REQUEST A NEW SERVICE FROM THE LOCAL ELECTRICAL SERVICE PROVIDER. 3. ELECTRICAL CONTRACTOR / OWNER TO REQUEST A NEW AIC (AMPERE INTERRUPTING CAPACITY) PROTECTION FROM THE LOCAL ELECTRIC UTILITY COMPANY. 4. ALL CONDUCTOR SIZES FOR THIS PROJECT SHALL BE THHN/THWN COPPER AWG OR KCMIL PER 2014 NEC TABLE310.15 (B) (16). 5. TRANSFORMER SHALL HAVE A DISCONNECTING MEANS LOCATED :N REMOTE LOCATION AND FIELD MARKED ON THE TRANSFORMER AS PER 2014 NEC ART. 450.14. LEGENDS: NEW WORK EXISTING TO REMAIN, U.O.N. DEMOLITION (E): EXISTING. FIELD TO VERIFY. (EF): EXISTING FEEDER. FIELD TO VERIFY. (N): NEW (R): EXISTING TO BE RELOCATED. 1! COMPLI NC Ne .� t14? 13 City T Tukwila BUILDING DIVISION SINGLE LINE DIAGRAM SCALE: NTS 1 JSuib.. CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4 # r."n'.:OII^I Pt'ip L1i„,CCn c ,,,. 114 E. IATELLA AVENUE ANAHEIM, CALIFORNIA 12105 F (714) 385.1835 F(714) 315-1134 'nwpiAPmFAm STAMP pit D. A. p �� ,G�pF was* `G4 Bak. Ke 0 q 34218 p < ' "est T E ' \G `. :NA L EXP. 03/19/21 PROJECT NAME/ADDRESS: Jdlibn • TUKWILA, SPACE 372 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER TUKWILA, WA & 368 LEVEL 1 MALL WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE 053119 CORPORATE REVISION 3 061819 1ST PERMIT SUBMITT 4 061819 HEALTH SUBMITTAL £z 071119 MECHANICAL CORRECT! A 072419 ELECTRICAL CORRECTIO A 080919 ELECTRICAL CORRECTIO A 031620 ADDENDUM 1 JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT GENERAL SINGLE LINE NOTES DIAGRAM & SHEET NO E-100 V-i - 05a9 GENERAL NOTES SEE ENLARGED POWER & LIGHTING PLAN r Jollibee 1, CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITION AT THE JOB SITE BEFORE COMMENCING ANY PHASE OF THE WORK. ADJUSTMENT FOR FIT AND COORDINATION SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 2. ELECTRICAL CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL, MECHANICAL & STRUCTURAL DRAWINGS AND SPECIFICATION FOR ANY ADDITIONAL REQUIREMENTS. 3. CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES. 4. ALL CONDUIT SHALL BE AS STRAIGHT AS POSSIBLE AND PARALLEL OR PENPENDICULAR TO THE BUILDING LINES. 5. PROVIDE MULTI -CONDUCTOR HOMERUNS AS SHOWN AND USE #10 AWG NEUTRAL. PROVIDE GREEN GROUND WIRE IN ALL RACEWAYS. 6. SEAL ALL WALL, ROOF AND FLOOR PENETRATION WITH UL LISTED FIRE SEALANT. 7. ALL CONDUIT SHALL BE ROUTED CONCEALED WITHIN WALLS AND OR ABOVE CEILINGS. 8. REFER TO ALL ARCHITECTURAL ELEVATIONS FOR EXACT MOUNTING HEIGHTS OF ALL DEVICES. 9. REFER TO All MECHANICAL DRAWINGS FOR ALL HVAC EQUIPMENT LOCATED ON ROOF. _` I ,-pp Fo 1 COMPLIANCE 'TN NFPA 70 - sec tiV f 31020 CRy of Tukw DUILTrNG DlV13ilaION NORTH ELECTRICAL SITE PLAN SCALE: 1 Jdlibs CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 1# RUPAPOROUP 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92005 P 1714) 311.1100 F(114) 115-1534 'wx FSWC V.wm STAMP 0,02D A. pl �G�aF IIASij'4. C� o z A 4 ;i q 34218 e.s est �F8 C151E�\�, %�� EXP. 03/19/21 PROJECT NAME/ADDRESS: Joflibss TUKWILA, SPACE 372 & WESTFIELD SOUTHCENTER 1374 SOUTHCENTER TUKWILA, WA 368 LEVEL 1 MALL WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE A 053119 CORPORATE REVISIONS 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL 2 071119 MECHANICAL CORRECTIONS 3 072419 ELECTRICAL CORRECTIONS Q 080919 ELECTRICAL CORRECTIONS /s\ 031620 ADDENDUM 1 JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT ELECTRICAL SITE PLAN SHEET NO F E200 1N6"=11-0" liaq—cczq ■ (E) D-23 • • SCOPE OF WORK D-23 (E) • (E) PNL "D" N 5 / D-23 (E) 35 C-35 C-14 L L f B 1-1. 30/32 L14-20R Al-9,11 C-30/32 C-40/42 C-36/38 A1-29/31 4 B-20 &7 25/2 C-29/31 c::B-4 15 L6-20R ■ -30/32 B-1 /21 C-12 Zi (E) PNL "A" 11 I91 19/ 17 B-4 6-20R 91/ B 14 16 AI-10 Al-12 Al-14 AI-16 Al-18 (ON ROOF) Al-20 (ON ROOF) L6-20R C-15 B-26 4 C-28 13 6 B-6 r ALL 120VOLTS, 20 AMP RECEPTACLES LOCATED UNDER COUNTERS WITHIN SERVICE AREA AND KITCHEN AREA TO BE SERVED FROM GFCI TYPE CIRCUIT BREAKERS PER 2017 NEC 210.8 (8) (2). GENERAL NOTES KEY NOTES 1. REFER TO ARCHITECTURAL PLANS FOR ALL DEVICE FINISHES. 2. CONTRACTOR SHALL REFER TO KITCHEN EQUIPMENT DRAWINGS FOR ALL EQUIPMENT AND CONTROLS (QUANTITIES AND LOCATIONS), AND REQUIRED CONTROL WIRING. 3. ALL RECEPTACLES AND SWITCHES PLATES SHALL BE IN COLOR SPECIFIED BY ARCHITECT. 4. E.C. SHALL REFER TO KITCHEN DWG(S) FOR ELEVATION EXACT HEIGHTS FOR ALL RECEPTACLES AND SWITCHES. 5. ALL WIRING, INCLUDING LOW VOLTAGE, SHALL BE IN CONDUITS. 6. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOMERUNS. PROVIDE AND INSTALLED CONDUITS, CONDUCTORS BOXES, MISC. FITTINGS, ETC. FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION AND N.E.C. 2017. 7. ALL 125V, SINGLE PHASE, 20A RECEPTACLE(S) INSTALLED IN THE KITCHEN SHALL HAVE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL, 2017 NEC ART. 210.8(B). 8. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET 24" MINIMUM. 9. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. 10. ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR. 1❑ DENOTES CIRCUIT DESIGNATION MINIMUM BRANCH CIRCUIT WIRING SHALL BE MINIMUM OF #12 AWG (HOT), #12 NEUTRAL PLUS #12 GROUND IN 3/4" CONDUIT (MIN.) TWO OR MORE CIRCUITS MAYBE INSTALLED IN ONE CONDUIT FOR BRANCH WIRING AND HOMERUN TO PANEL PER PROVISION OF 2014 N.E.C. PROVIDE #10 AWG WHEN TWO OR THREE CIRCUITS SHARE A COMMON NEUTRAL. PROVIDE 100A, 120/208V 3 PHASE, 4 WIRE, PANEL "Al" E EXISTING 200A, 120/208V, 3 PHASE, 4 WIRE, PANEL "B" TO BE DEMOLISHED AND REPLACE WITH NEW 200A, 120/208V, 3 PHASE. 4 WIRE, PANEL "B" LOCATED BESIDE TO PANEL "C". EC TO VERIFY EXACT LOCATION BEFORE ROUGH -IN. D E, 4 REPLACE WITH NEW 100A, 120/208V, 3 PHASE 4 WIRE, 42 SPACES, PANEL "C". ❑5 KEEP 3 FEET CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT PER 2017 N.E.C. CODE REQUIREMENTS. 15 THE 11 A, 1/ 1: 3P RE SPA ES, P EL AN © WALK-IN COOLER AND WALK-IN FREEZER MUST COMPLY INSTALLATION RACEWAY SYSTEM PENETRATIONS MUST BE SEALED AS PER 2014 NEC ART. 300.7. Q7 E.C. TO PROVIDE 1" CONDUIT WITH PULL CORD STUB AT ACCESSIBLE CEILING SPACE RUN THRU EXISTING MAIN TELEPHONE BACKBOARD. EC TO COORDINATE WITH TELEPHONE/DATA INSTALLER BEFORE ROUGH -IN. PROVIDE 208V, 10, 2P, 3W, 20 AMP RECEPTACLE NEMA 6-20R WITH 3 #10 & 1 #I0 GND. PROTECTED BY GFC CIRCUIT BREAKER AS PER 2017 NEC ART. 210.8 (B). ❑9 PROVIDE 125/25DV, 10, 4P. 4W, 20 AMP RECEPTACLE, NEMA LI 4-20R WITH 4 #10 & 1 #10 GND. PROTECTED BY GFC CIRCUIT BREAKER AS PER 2017 NEC ART. 210.8 (B). 10 PROVIDE 250V, 30, 4P, 4W. 50 AMP RECEPTACLE, NEMA 15-50R WITH 4 #8 & 1 #10 t2 13 GND. PROTECTED BY GFC CIRCUIT BREAKER AS PER 2014 NEC ART. 210.8 (B). PROVIDE 250V, 10, 2P, 3W, 20 AMP RECEPTACLE, NEMA L6-20R WITH 3 #10 & 1 #10 GND, PROTECTED BY GFC CIRCUIT BREAKER AS PER 2014 NEC ART. 210.8 (B). HEAT TRACE GROUND FAULT PROTECTION OF EQUIPMENT SHALL BE PROVIDED FOR HEAT TRACING AND HEATING PANELS. B-33/35 Al .35 B-12 B-31- I i POWER PLAN 1 i COMPLIANCEF NFPP. TO - NEC I'".' 2 3 DE City of Tukwila OULLDING DIVISION NORTH SCALE 1/4"=1'-0" 1 MIPS, CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4. 911 E. AATELLA AVENUE ANAHEIM. CALIFORNIA 9700E P (714) 70F1E76 F1711) 706.18N WPOSPO N10.tom STAMP �G��F 2, pR(lA.p pi WMy o z 9 34218 1/4, fS% (C/SiEE‘‘C\a4 EXP• 03/19/21 PROJECT NAME/ADDRESS: JSlib.. TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE Ai 053119 CORPORATE REVISIONS 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL A 071119 MECHANICAL CORRECTIONS A 072419 ELECTRICAL CORRECTIONS A 080919 ELECTRICAL CORRECTIONS 5 031620 ADDENDUM 1 JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT POWER PLAN SHEET NO E300 as-osof mt 2 W 1_- REMARKS PLUMBING ELECTRICAL JOLLIBEE 12/27/2018 LJ M, t F M, r - REMARKS PLUMBING ELECTRICAL JOLLIBEE 1/15/2019 GAS WASTE HOT WATER COLD WATER CONNECTION LOAD PHASE VOLTS IINSTALLED BY PURCHASED BY' MODEL NUMBER MANUFACTURER < = CI DESCRIPTION GAS WASTE HOT WATER COLD WATER CONNECTION LOAD PHASE tn INSTALLED BY PURCHASED BY MODEL NUMBER MANUFACTURER r Z j DESCRIPTION SIZE RIH MBTU TYPE SIZE RIH SIZE RIH SIZE RIH TYPE AMPS KW HP SIZE RIH MBTU TYPE SIZE RIH SIZE RIH SIZE RIH TYPE AMPS KW HP 58 FS D 120 1 (E) WALK-IN FREEZER 58 JOLLIBEESERVINGAREA EQUIPMENT 59 GC GC MILLWORK BY GC 1 CREW TABLE 591 GC TO MODIFY PER PLAN GC CUSTOM BY GC 1 EXISTING FRONT COUNTER 1 60 0 0 2 CREW CHAIR 602 C 120 0 0 5-LINE II PIONEER POS 2 EXISTING POS TERMINAL 2 61 SEECAPTIVAIRE GC GC CAPTIVEAIRE 2 FIRE SUPPRESSION CABINET 613 NEMA5-15P SC 10AFF C 4.9 0.2 1 115 GC 0 TSSU-27-12M-B-ADA TRUE 1 COLD TABLE 3 61.1 GC GC 1 FIRE SUPPRESSION PULL BOX 61.14 GC 0 CUSTOMS/S ALLSTRONG 1 ICE SHAVER TABLE 4 62 FOR FRENCH FRIES FRYER GC 0 CUSTOM S/S ALLSTRONG 1 12" S/S WORK TABLE 62 4.1 FS GC 0 CUSTOM S/5 ALLSTRONG 1 ICE BIN 4.1 62.1 FOR GRIDDLE GC 0 CUSTOMS/S ALLSTRONG 1 12" S/S WORK TABLE 62.1 4.2 NEMA5-15P FS C 3.8 0.225 1 115 GC 0 HC-8E HATSUYUKI 1 ICE SHAVER 4.2 62.2 FOR HALO HALO - GC 0 CUSTOMS/S ALLSTRONG 1 24"X30"WORKTABLE 62.25 NEMA5-15-P SC C 4 115 GC 0 2SF GLOBAL INC. 1 CHEST TYPE FREEZER 5 63 - 2 TRASH BIN 63 6 _ GC 0 CUSTOM S/S ALLSTRONG 1 BACK COUNTER 6 64 NOTE USED 64�6.1 D 1/2 1/2 GC 0 HS-16151N ALLSTRONG 1 DROP IN HAND SINK 6.1 65 C 1.5 120 GC 0 EV9437-42 EVERPURE 1 MAIN WATER FILTER 65 6.2 GC 0 CUSTOM S/5 ALLSTRONG 1 S/S ICE BIN 6.2 66 NEMA 5-15P C 5.4 1/2 1 115 GC 0 T-49-HC TRUE 1 2 DOOR CHILLER 66 7 _ GC 0 CUSTOMS/5 ALLSTRONG 1 ASSEMBLY COUNTER 67 NEMA 5-14 C 13 1.55 1 120 GC 0 RCS1OTS AMANA 1 CREW MICROWAVE 67 8 GC 0 CUSTOM 5/5 ALLSTRONG 1 STEAM TABLE 8 68 NOT USED NOTE USED 68 8.1 STEAM TABLE INSERT FS D 8.7 1.8 1 208 GC 0 MOD-200D WELLS 1 FOOD WARMER 8.1 67 NOT USED _ _ NOTE USED 69 8.2 STEAM TABLE INSERT 3/8 GC GC B-0208 T & S BRASS 1 FAUCET FILLER 8 2 JOLLIBEE MISCELLANEOUS 8.3 STEAM TABLE INSERT FS 3/4 3/8 GC 0 3041 FISHER 1 DIPPER WELL 8.3 GC TO PROVIDE MOUNTING 8.4 STEAM TABLE INSERT GC 0 CUSTOMS/S ALLSTRONG 1 OVERHEAD SHELF 8.4 70 BRACKET AND DATA OUTLET C 1 115 GC 0 48" SAMSUNG 5 MENU BOARD 70'8 5 STEAM TABLE INSERT D 9.3 1.12 1 208 GC 0 GRAHL-24D HATCO 1 HEAT LAMP 8.5 GC TO PROVIDE MOUNTING 9 NEMAL14-20P C 17.5 4.2 1 120/208 GC 0 GRSDH-60D HATCO 1 HORZONTALFOODWARMER 9 71 BRACKET AND DATA OUTLET C 1 115 GC 0 TD222021 VIEWSONIC 2 ORDER MONITOR 71 10 NOT USED NOTE USED 10 73 84AFF C 55 1 115 GC 0 MAXIMA ECOLAB 2 FLYTRAP 7311 NOT USED NOTE USED 11 JOLLIBEE OFFICE ACCESSORIES 12 NEMA 5-15P C 3 0.34 0.16 1 115 GC 0 D15-3 CRATHCO 2 JUICE DISPENSER 12 80 SEE ENLARGED PLAN - GC GC MILLWORK BY GC 1 MANAGER'S DESK 80 13 NEMAS-15P C 131 1.57 1 120 GC 0 VP17-2-BLK BUNN-O-MATIC 1 COFFEE DISPENSER 13 81 SEE ENLARGED PLAN GC 0 1 MANAGER'S CHAIR 81 1 4 GC 0 C2410C SAN JAMAR 2 (E) CUP DISPENSER 14 82 SEE ENLARGED PLAN C 1 115 GC GC 522E4050B SAMSUNG 1 CCTV MONITOR 82 14.1 GC 0 C2410C SAN JAMAR 1 (N) CUP DISPENSER 14.1 =Y12. SEE ENLARGED PLAN C 1 115 GC 0 1 COMPUTER MONITOR 8315 1 ( E) BEVERAGE COUNTER 15 SEE 15.1 1 (E)COUNTER TOP TRASH RECEPTACI 15.1 84 32CHANNELDPLAN C 1 115 GC GC CSMA 1220 JBL 1 AMPLIFIER 8416 FS 3/4 3/8 C 9.3 1 115 IDC215 CORNELIUS 2 (E) SODA DISPENSER 16 84.1 SEE ENLARGED PLAN C 1 115 GC GC BDP-5590 SONY 1 DVD PLAYER 841 16.1 W/ FILTERED COLD WATER FS 3/4 3/8 48ACH C 20.1 6.8 1 115 CIM053OR ICE-O-MATIC 2 (E) ICE MAKER 16.1 85 SEE ENLARGED PLAN 1 115 GC 0 1 COMPUTER/KEYBOARD 8516.2 ON ROOF D 6 1 115 RCA-1001 ICE-O-MATIC 2 (E)REMOTECONDENSER 16.2 86 SEE ENLARGED PLAN 1 115 GC 0 TRIPP LITE 1 SERVER CAGE 86 16.3 BELOW COUNTER C 120 2 (E)SODA MACHINE COMPRESSOR 16.3 87 SEE ENLARGED PLAN C 1 115 GC 0 MFC-9130CW BROTHER 1 PRINTER/SCANNER/FAX 87 JOLLIBEE KITCHEN AREA EQUIPMENT 88 SEE ENLARGED PLAN GC GC MILLWORK BY GC 1 FILE CABINET 88 21 3/410ACH 112 GC 0 IHPA-2-24 IMPERIAL 1 2 BURNER HOT PLATE 21 89 SEE ENLARGED PLAN GC GC MILLWORK BY GC 1 WALLSHELVINGS 8921.1 GC 0 CUSTOMS/S ALLSTRONG 1 s/sBURNERSTAND 21.1 90 ON 6" CONC. CURB _ GC 0 1 VAULT 90 22 NEMA 15-SOP FS 3/4 3/4 8.5 ACH C 42 15 3 208 GC 0 E62083E150 ACCUTEMP FS - INDIRECT WASTE TO FLOOR SINK D - DIRECT CONNECTION ACH - ABOVE 0 - OWNER SC- SIGN CONTRACTOR W/ CW FILTERED WATER 1 RICE STEAMER 22 D- DIRECTWASTE C- CONVENIENCEOUTLET COUNTER HEIGHT GC - GENERAL CONTRACTOR KEC-KITCHEN EQUIPMENT CONTRACTOR 22.1 GC 0 CUSTOMS/S ALLSTRONG 1 EQUIPMENT STAND W/ CASTERS 22.1 LEGENDS SC - SELF CONTAINED FS- FLOORSTUB-OUT EC - ELECTRICAL CONTRACTOR 23 3/4 90 FS 11/4 3/8 C 1 120 GC 0 FGP55 FRYMASTER 1 RETHERMALIZER 23 ACH - ABOVE COUNTER HEIGHT DC - DROPPED CORD ES - EQUIPMENT SUPPLIER 24 W/ FILTERED COLD WATER 3/4 5.3 AFF 80 FS 1 1/4 1/4 5.3AFF C 8 120 GC 0 GPCRB FRYMASTER 1 PASTA COOKER 24 25 NOT USED NOTE USED 25 26 NEMA 5.15P 3/4 7ACH 50 7ACH C 4 120 GC 0 GGF201A2400-TI ACCUTEMP 1 GRIDDLE 26 26.1 GC 0 CUSTOMS/S ALLSTRONG 1 EQUIPMENT STAND W/ CASTERS 26.1 27 NOT USED NOTE USED 27 28 NEMA5-15P C 15 1.75 1 120 GC 9 300NDNL THERMODYNE 1 BURGER HOLDING CABINET 28 28.1 NEMA S-15P SC C 5 0.3 1 115 GC 0 TUC-27F-HC TRUE 1 FREEZER BASE 28.1 29 NEMA 5-15P SC C 4.9 0.2 1 115 GC 0 TSSU-27-12M-B-ADA TRUE 2 SANDWICH TABLE 29 29.1 SC GC 0 CUSTOMS/S ALLSTRONG 2 OVERHEAD SHELF 29.1 29.2 NEMA6-20P C 15.4 3.2 1 208 GC 0 RC2252 AMANA 2 MICROWAVE 29.2 30 NEMA5-15P C 14.7 1.8 120 GC 0 VCT-25 ROUNDUP 1 BUN TOASTER 30 30.1 GC 0 CUSTOM S/S ALLSTRONG 1 S/S BUN TOASTER STAND 30.1 31 GC 0 CUSTOMS/S ALLSTRONG 1 STEAM TABLE 31 31.1 STEAM TABLE INSERT FS 1/2 D 6.9 0.8 1 208 GC 0 HSW-60 WELLS 1 FOOD WARMER 31.1 31.2 STEAM TABLE INSERT FS 1/2 D 10 1.2 1 120 GC 0 MOD-100D WELLS 1 FOOD WARMER 31.2 31.3 STEAM TABLE INSERT FS GC 0 CUSTOMS/S ALLSTRONG 1 SMALL COLD PAN 31.3 31.4 NEMA 6-20P C 22 4.5 208 GC 0 FR-4 HATCO 1 ELECTRIC WARMERS 31.4 31.5 STEAM TABLE INSERT 3/8 GC GC B-0580 T&SBRASS 1 POT FILLER 31.5 31.6 _ GC 0 CUSTOM S/S ALLSTRONG 1 OVERHEAD SHELF 31.6 31.7 NEMA 14-20P C 11.2 1.34 1 120 GC 0 GRSDS-41 HATCO 1 HORZONTAL FOOD WARMER 31.7 32 NEMA 5-15P 3/4 7 AFF 100 C 10 1.2 1 120 GC 0 PFG-691 HENNY PENNY 4 CHICKEN JOY FRYER 32 33 3/4 80 C 9 120 GC 0 FPH155-2CSE FRYMASTER 2 FRENCH FRIES FRYER 33 34 C 5 0.3 1 115 GC 0 TUC-27F-HC TRUE 1 FREEZER BASE 34 35 NEMA 5.15P SC C 3 1/5 1 115 GC 0 T-23-HC TRUE 1 REACH IN REFRIGERATOR 35 36 GC 0 CUSTOMS/S ALLSTRONG 1 BREADING TABLE 36 36.1 FS 3/8 GC 0 2901-6" FISHER 2 FAUCET 36.1 36.2 GC 0 CUSTOM VS ALLSTRONG 3 BREADING PAN 36.2 36.3 GC 0 CUSTOM S/5 ALLSTRONG 3 ICE BIN 36.3 37 C 0.1 120 GC 0 WRS-1088B5 SMART CHEF 2 RICE WARMER 37 37.1 GC 0 CUSTOM S/S ALLSTRONG 1 MOBILE RICE WARMER TABLE 37.1 38 NEMA-15P 24AFF C 4.2 0.5 1 120 GC 0 82060 SERVER PRODUCT 2 FOOD WARMER 38 38.1 NEMA-5-15P 25AFF C 4.6 1 120 GC 0 6100A NEMCO 1 BURGER GRAVY DISPENSER 38.1 39 FS 3/4 3/8 D 27.7 1 208 GC 0 ICE1806HR ICE-0-MATIC 1 ICE MAKER 39 39.1 FS 1 GC 0 B100PS ICE-O-MATIC 1 ICE BIN 39.1 39.2 ON ROOF D 2.6 1 208 GC 0 VCR-5061B ICE-O-MATIC 1 REMOTE CONDENSER 39.2 40 PROVIDE DATA OUTLET C 20 120 GC 0 RT1 2 EXISTING OIL POLY TANK 40 41 41"AFF GC 0 RTI 1 EXISTING OIL POLY TANK FILL BOX 41 42 18x24x12TUB FS 1 1/2 1/2 GC 0 53E11824-2024-C ALLSTRONG 1 3-COMPARTMENT SINK 42 42.1 GC GC B-0231 T & S BRASS 1 FAUCET 42.1 42.2 GC GC B-0133-ADF12-B T&S BRASS 1 PRE -RINSE FAUCETw/ FAUCET 42.2 42.3 GC 0 CUSTOM S/S ALLSTRONG 2 S/SWALL SHELF 42.3 42.4 NEMA 5-15 FS C 12 15 1 110 GC GC 40GAL CHEMX WORKS 1 D-CARBONATOR 42.4 43 GC 0 CUSTOM S/S ALLSTRONG V S/S SPLASH GUARD 43 44 18x18x12TUB FS 1 1/2 1/2 GC 0 S1B1818-1D18-C ALLSTRONG 1 PREP SINK 44 44.1 GC GC T&SBRASS 1 FAUCET 44.1 45 PREP SINK GC 0 CUSTOM S/S ALLSTRONG 2 60" X 15" S/S WALL SHELVES 45 45.1 HALOHALO STATION GC 0 CUSTOM S/S ALLSTRONG 1 72" X 15" S/S WALL SHELF AT 45.1 45.2 CREW STATION GC 0 CUSTOM S/S ALLSTRONG 1 36" X 15" S/S WALL SHELF 45.2 46 W/ SPLASH GUARD D 1/2 1/2 GC 0 HAS ALLSTRONG 2 WALL MOUNT HAND SINK 46 46.1 GC 0 CUSTOM CUSTOM 3 PAPER TOWEL & SOAP DISPENSER- 46.1 46.2 ACCESSORY TO HAND SINK GC 0 GUAG1100 ACKLANDS GRANGER 2 EYE WASH 46.2 _ 47 GC 0 METRO V S/S WIRE SHELVING 47 47.1 V (E) WETWIRESHELVINGS 47.1 48 1 (E) BAG -IN -A -BOX 48 49 2 (E) CO2 TANK 49 49.1 2 (E)CO2FILLBOX 49.1 3 (E) LOCKER 50 51 1 (E)BACKDOORAIRCURTAIN 51 52 1 (E) BACK OF HOUSE S/S MOP SINK 52 52.1 1 (E) CHEMICAL SHELF W/ MOP RACK 52.1 52.2 SEE PLUMB. DWG 1/2 1/2 1 (E) MOP SINK FAUCET 52.2 53 SEE PLUMB. DWG 3/4 18" 199 C 120 CYCLONE AO SMITH 1 (E) GAS WATER HEATER 53 54 SEE MECH. DWG GC GC SEE MECH. DWG. CAPTIVEAIRE 1 EXHAUST HOOD TYPE I 54 SCALE: 55 SEE MECH. DWG GC GC SEE MECH. DWG. CAPTIVEAIRE 1 EXHAUST HOOD TYPE I 55 KITCHEN EQUIPMENT SCHEDULE 1 56 3/4 C 14.7 3 1 208 GC 0 HHC990 HENNY PENNY 1 CHICKEN HOLDING CABINET 56 NTS 57 FS _ D 120 1 (E) WALK-IN COOLER 57 - CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4 PLOUPI 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 82805 P IT14) 385.1835 F(714) 385-1834 STAMP V,, p,R D. A. p< �0 WAS*�yC??,,o z s ,p 34218 4Q ��S, cO LEc/ ICNr\a� EXP. 03/19/21 PROJECT NAME/ADDRESS: Jdlibss TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE Qf 053119 CORPORATE REVISIONS 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL A 071119 MECHANICAL CORRECTIONS Es 072419 ELECTRICAL CORRECTIONS A 080919 ELECTRICAL CORRECTIONS s 031620 ADDENDUM 1 �F/LVIC1:1 Ft,...;V .1 1 City of Tukwila 1 !<;N4€P4'C JVVCIC/4 ' JOB NUMBER MEP # 1901069 DRAWN BY DRAWN BY CHECKED BY PEI PEI SHEET CONTENT KITCHEN EQUIPMENT SCHEDULE SHEET NO E-301 GENERAL NOTES r58.3 59 60 61 61.8 1. FIXTURES SHALL BE COMPLETELY FACTORY ASSEMBLED, WIRED AND EQUIPPED WITH ALL NECESSARY SOCKETS, LED DRIVER, SUPPORTING HARDWARE AND ACCESSORIES. PLEASE REFER TO ARCHITECTURAL DWG(S) FOR INDIVIDUAL FIXTURE DESCRIPTION. 2. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS, BOXES, MISC. FITTINGS, ECT, FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION AND N.E.C. (2017). 3. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURES LOCATION AND DETAILS. SUBSCRIPTS IN LIGHTING PLAN DENOTES SWITCH. EXAMPLE: 2A, 2 DENOTES CIRCUIT NUMBER AND A DENOTES SWITCH THAT CONTROLS CORRESPONDING LIGHTS. 4. HALF -SOLID HATCHED FIXTUREIS) INDICATES EMERGENCY FIXTUREIS). 5. VERIFY ALL LIGHTING FIXTURES AND SWITCHES MOUNTING HEIGHTS AND LOCATIONS IN THE FIELD. 6. VERIFY EXACT LOCATION AND MOUNTING HEIGHT OF LIGHT FIXTURES AND DOT SIGNS WITH ARCHITECTURAL PLANS AND TENANT, PRIOR TO ROUGH -IN. COORDINATE EXACT LIGHT FIXTURE LOCATIONS WITH CABINETRY, MILLWORK. TABLES, REFRIGERATION PIPING, DUCTWORK AND OTHER TRADES TO AVOID CONFLICTS. CONTRACTOR SHALL BE RESOLVED PRIOR TO INSTALLATION OF LIGHT FIXTURES. 7. PROVIDE A MINIMUM OF 6'-0" SLACK CONDUCTORS AT EACH JUNCTION BOX CONNECTING POWER TO LIGHT FIXTURES. 8. THROUGH WIRING OF RECESSED LIGHT FIXTURES, IN SUSPENDED CEILINGS, IS NOT PERMITTED. CONNECT EACH LIGHT FIXTURE BY A WHIP TO JUNCTION BOX. 9. PROVIDE CABLE WHIPS OF SUFFICIENT LENGTHS TO ALLOW FOR RELOCATING EACH LIGHT FIXTURE WITHIN A 5-FOOT RADIUS OF ITS INSTALLED LOCATION, BUT NOT EXCEEDING 6 FEET IN UNSUPPORTED LENGTHS. 10. AU. LIGHTING FIXTURES SHALL BE SUPPORTED PER 2017 NEC ART. 410.16 (C). KEY NOTES �1 REPLACE EXISTING SWITCH WITH A NEW DIMMER. W NEW VACANCY SENSOR. PROVIDE ULTRASONIC OCCUPANT SENSOR WITH 500 SQUARE FEET CONTROL AREA, OR APPROVED EQUAL. E CONNECT NEW EXIT SIGN TO THE NEAREST LIGHTING BRANCH CIRCUIT. ■ ■ / \\ SCOPE `\ OF WORK \\ JEN'. III (E) PNL "D" • 7 la 1a (E)PNL "A"I la L (N) PNL "B" (N) PNL "C" �-i 3 (N) PNL la 1b 1b l0 E.1 NORTH F LIGHTING PLAN SCALE: CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS, THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4 0 PLUPAPOROUP 911 E. AATELLA AVENUE ANAHEIM, CALIFORNIA 92$09 P (TN 3/9.1931 F(714) 385.1134 TNN/FANC11111911.11 STAMP p,R D. A. p PA G��F WAS41 `G4, 0 y 342113O -Me CCIT, STF.N�t �� EXP. 03/19/21 PROJECT NAME/ADDRESS: "sibs. TUKWILA, SPACE 372 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER TUKWILA, WA & 368 LEVEL 1 MALL WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE A 053119 CORPORATE REVISIONS 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL t32 071119 MECHANICAL CORRECTIONS 072419 ELECTRICAL CORRECTIONS i080919 ELECTRICAL CORRECTIONS 031620 ADDENDUM 1 JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT LIGHTING PLAN SHEET NO E400 1/4"=1'-0" ulqr 0tz5 KEY NOTES: (E) 6 1 (E) D-25/27/2 (E) C-18 26/28/30 (E) c., `J n 7 (E) 7E (ET (N) (E) (RTU \ (N) 6 /J 7/39/41 1 7 C-18 wit O 0 �1 HOMERUN TO PANELBOARD CIRCUITS & RECEPTACLES SHOWN ARE TO BE TIED/ CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS DESIGNATED. (TYPICAL FOR ALL HOMERUN CIRCUITS). 2Q ELECTRICAL CONTRACTOR TO PROVIDE SERVICE DISCONNECTS. O PROVIDE WEATHERPROOF GFI ROOF MOUNTED SERVICE RECEPTACLES LOCATED WITHIN 25 FEET OF ANY MECHANICAL EQUIPMENT AS PER 2014 NEC ART. 210.63. [J 30AS, 3P, 250V DISCONNECT SWITCH, WITH 30A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURERS INSTALLATION RECOMMENDATIONS. PROVIDE 3/4°C, 3 #8 & 1 #10 GND. 5❑ PROVIDE COMBINATION WEATHERPROOF MAGNETIC STARTER/DISCONNECT WITH NEMA 00 STARTER AND FUSES PER MANUFACTURERS NAMEPLATE RATINGS. © 30AS, 3P, 250V DISCONNECT SWITCH, WITH 25A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 3/4"C, 3 #10 & 1 #10 GND. M 30AS, 3P, 250V DISCONNECT SWITCH, WITH 20A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 3/4"C, 3 #12 & 1 #10 GND. ® 30AS, 2P, 250V DISCONNECT SWITCH, WITH 20A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 3/4"C, 3 #12 & 1 #10 GND. W PROVIDE 3/4"C, 3 #10 & 1 #10 GND. 10 ALL WIRING SHALL BE COPPER, #12 AWG MINIMUM, TYPE THNN/THWN AND RATED FOR 600 VOLTS. LI 60AS, 3P, 250V DISCONNECT SWITCH, WITH 50A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 1 1/4"C, 3 #6 & 1 #10 GND. GO FPF T !W 11t i . J LJ;u CRy of Tukwila BUILDING DIVISION NORTH ELECTRICAL ROOF PLAN SCALE: CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 41# PL 0um 911 E. AAUELLA AVENUE ANANEIN, CALIFORNIA 92506 P (711) 96Y1035 9714) 366.1631 NINA0UIWWNIF.0211 STAMP c ltedA p,R R A. A, G a OF W AS/j 4. C 0 34218 ometSOC/STEENN\$�� EXP. 03/19/21 PROJECT NAME/ADDRESS: "lib.. TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE ,A, 053119 CORPORATE REVISIONS 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL A 071119 MECHANICAL CORRECTIONS 3 072419 ELECTRICAL CORRECTIONS 080919 ELECTRICAL CORRECTIONS A 031620 ADDENDUM 1 JOB NUMBER MEP # 1901089 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT ELECTRICAL ROOF PLAN SHEET NO E500 1/4"=1'-0" VAck-091 (N)PANEL "Al" VOLTS:120/208V PHASE: 3 A.I.C. RATING: 10,000 AMP MAIN: 100A C.B. MOUNTING: SURFACE WIRE: 4 BUSSING: 225 AMP LOAD ' A -VA B-VA C-VA BKR CT CT BKR A -VA B-VA C-VA * LOAD CREW MICROWAVE K 1560 20/1 1 2 20/1 720 R CASHER FLY TRAP C 300 20/1 3 4 30/2 2600 K SOFT SERVE FREEZER FLYTRAP C 300 20/1 5 6 - 2600 K --• AIR CURTAIN K 612 20/1 7 8 20/1 600 K COLD TABLE FOOD WARMER K 1008 20/1 9 10 20/1 1116 K SODA DISPENSER RICE WARMER, GRAVY DISPENSER K 1108 20/1 11 12 20/1 1768 K ICE MAKER SPARE 0 20/1 13 14 20/1 1236 K SODA DISPENSER CASHER R 1080 20/1 15 16 20/1 1788 K ICE MAKER CASHER R 720 20/1 17 18 20/1 720 K ICE MAKER COND. CASHER R 720 20/1 19 20 20/1 720 K ICE MAKER COND. CASHER/PRINTER R 360 20/1 21 22 20/1 SPARE RTI RECEPTACLES R 1000 20/1 23 24 20/1 720 K JUICE DISPENSER STORAGE RM RECEPTACLES R 360 20/1 25 26 20/2 500 R KITCHEN AREA EASTSIDE RECEPT CASHER R 720 20/1 27 28 - • 500 R --- FOOD WARMER K 1498 20/2 29 30 2011 200 N SD & SF DETECTOR -.. K r 1498 -- 31 32 20/1 456 K ICE SHAVER EF-2 M 2041 25/3 33 34 20/1 480 K CHESTTYPEFREEZER -- M 2041 - 35 36 20/2 ' 1340 K DRIVE THRU FOOD WARNER M 2041 -- 37 38 - r 1340 K --- ICE MAKER K 2881 35/2 39 40 20/1 SPARE K r 2881 - 41 42 20/1 SPARE PHASE TOTALS: 12363 14874 16916 44153 =TOTAL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 102.9 123.9 140.9 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS: 1.25 X 0 = 0 VA C=CONT1NUOUS LOADS, OTHER: 1.25 X 600 = 750 VA M=MOTOR LOADS (INCL LGST): 1.00 X 6123 = 6123 VA LARGEST, VA: 0.25 X 0 = 0 VA R=RECEPTACLES: 1ST 10K: 1.00 X 6680 = 66130 VA BALANCE: 0.50 X 0 = 0 VA K=KITCHEN LOADS: QTY: 17 0.65 X 30550 = 19858 VA N=NONCONTINUOUS LOADS, OTHER: 1.00 X 200 = 200 VA NOTES: (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 33611 VA = 93.3 AMPERES (N)PANEL "C" A VOLTS:120/208V PHASE: 3 A.I.C. RATING: 10,000 AMP MAIN: LO MOUNTING: SURFACE WIRE: 4 • AMP LOAD ' A -VA B-VA OVA BKR CT - CHICKEN FRYER K 1200 20/1 2 20/1 1600 K COFFEE DISPENSER CHICKEN FRYER K 1200 20/1 3 CHICKEN FRYER K 1200 20/1 5 6 20/1 1800 K HONDING CABINET CHICKEN FRYER K 1200 20/1 7 8 20/2 1602 K MICROWAVE RICE STEAMER K 5041 60/3 9 10 - ' 1602 K --- -- K r 5041 -- 11 12 20/1 648 K 2 DOOR CHILLER K r 5041 - 13 14 20/1 1080 K FRENCH FRIES FRYER RETHERMALIZER K 120 20/1 15 16 20/1 1080 K FRENCH FRIES FRYER SPARE 20/1 17 18 20/1 r 1080 R ROOF RECEPTACLES SPARE 20/1 19 20 20/3 300 M (E)MUA-1 FROZEN BEVERAGE FREEZER K 1768 25/2 21 22 - 300 M - K r 1768 -- 23 24 - 300 M - AR CURTAN M 612 20/1 25 26 20/1 SPARE SPARE 20/1 27 28 20/1 1200 K LIGHT DOORMEATER INC ROWAVE K 1602 20/2 29 30 20/2 967 C HEAT LAMP K n 1602 -- 31 32 - ' 967 C --- PASTACOOKER K 960 20/1 33 34 20/1 480 K GRIDDLE 36 20/2 900 K FOOD WARNER RTU-6 M r 3879 50/3 37 8 - 900 K ___ M 7 3879 -- 39 40 2012 1560 K HORIZONTAL FOOD WARMER --. M 3879 -- 41 2 - 1560 K - PHT TALQ S� 983 622 2 =T AL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) `JE �� J`�1 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS: 1.25 X 0 = 0 VA C=CONTINUOUS LOADS, OTHER: 1.25 X 1934 = 2418 VA M=MOTOR LOADS (INCL LGST): 1.00 X 13149 = 13149 VA LARGEST, VA: 0.25 X 0 = 0 VA R=RECEPTACLES' 1ST 10K: 1.00 X 1080 = 1080 VA NOTES: BALANCE: 0.50 X 0 = 0 VA K=KITCHEN LOADS: (DIY: 23 0.65 X 46119 = ' 29977 VA N=NONCONTINUOUS LOADS, OTHER: 1.00 X 0 = 0 VA (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 46624 VA = 129.4 AMPERES "B" (N)PANEL VOLTS:120/208V PHASE: MOUNTING: SURFACE WIRE: 3 A.I.C. RATING: 10,000AMP MAIN: LO 4 BUSSING: 225 AMP LOAD A -VA B-VA OVA BKR CT CT BKR A -VA B-VA C- ' L AD �_ LIGHTING L 600 20/1 1 2 20/1 1100 LIGHTING L 200 20/1 3 4 20/1 r 720 R ORDER MONITOR HOTDOGSTEAIvER K 1800 20/1 5 6 20/1 1000K WALK-IN COOLER SAJDVv1CH TABLE K r 1176 20/1 7 8 20/2 1040 K COOLER COMP F000 WARMER K 1008 20/1 9 10 - r 1040 K --- R • F 12 20/1 1000 K WALK-IN FREEZER SPARE 0 20/1 13 4 20/2 1040 K FREEZER COMP SPARE 0 20/1 15 6 - ' 1040 K --- SPARE 0 20/1 17 18 20/1 900 R MENU K 6 20 20/1 1200 K FOOD WARMER K r 1602 -- 21 22 20/1 SPARE DINING AREA2 RECEPTACLES K 1r 540 20/1 23 24 20/1 r 360 R KITCHEN AREA EASTSIDE RECEPT FOOD WARMER K ' 717.6 20/2 25 26 20/1 1440 K D-CARBONATOR --- K A 717.6 - 27 28 20/1 360 R TEL BACKBOARD MANAGER OFC R ' 1080 20/1 29 30 20/2 1534 K CHICKEN HOLDING CABINET MANAGER OFC R ' 540 20/1 31 32 - ' 1534 K -•- REMOTE CONDENSER K 270.4 15/2 33 34 20/1 820 C GAS HEATER/WATER FILTER --- K r 270.4 -- 35 36 20/1 576 K FREEZER BASE SPACE 37 38 100/3 ' 12363 N PANEL "A1' SPACE 39 40 - '14874 N --- SPACE 41 42 - n 16916 N -- PHASE TOTALS: 24353 22652 26636 73641 =TOTAL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 202.8 188.6 221.8 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS: C=CONTINUOUS LOADS, OTHER: M=MOTOR LOADS (INCL LGST): LARGEST, VA: R=RECEPTACLES: 1ST10K: BALANCE: K=KRCHENLOADS: OTY: N=NONCONTINUOUS LOADS, OTHE 1.25 X 800 = 1000 VA 1.25 X 820 = 1025 VA 1.00 X 0 = 0 VA 0.25 X 0 = 0 VA 1.00 X 5060 = 5060 VA 0.50 X 0 = 0 VA 1.00 X 44153 = 44153 VA NOTES: (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 66063 VA = 183.4 AMPERES (E)PANEL "D" VOLTS:120/208V PHASE: 3 A.I.C. RATING: 10,000AMP MAIN: LO MOUNTING: SURFACE WIRE: 4 BUSSING: 225 AMP LOAD * A -VA B-VA C-VA BKR CT CT BKR A -VA B-VA C-VA ' LOAD RTU-1 M 1872 25/2 1 2 20/1 1250 L LIGHTING M 1872 -- 3 4 20/1 1250 L LIGHTING RTU-2 M 1872 25/2 5 6 20/1 1050 L LIGHTING --- M 1872 -- 7 8 20/2 950 L LIGHTING RTU-3 M 2520 35/3 9 10 20/1 950 L LIGHTING -- M ' 2520 -- 11 12 20/1 1150 L LIGHTING --- M 2520 -- 13 14 20/2 360 R CONVENIENCE OUTLET RTU-4 M 2520 35/3 15 16 20/1 0 SPARE -- M T 2520 -- 17 18 20/1 0 SPARE --- M ' 2520 -- 19 20 45/3 3720 M RTU-5 ROOF RECEPTACLES R 540 20/1 21 22 -- ' 3720 M --- CONVENIENCE OUTLET R 900 20/1 23 24 - r 3720 M -- MUA•1 & MUA•2 M 1830 20/3 25 26 20/3 1740 M CU•3 -- M 1830 27 28 - 1740 M -- --- M 1830 -- 29 30 - A 1740 M -•- SPARE 20/1 31 32 20/3 2568 M CU•2 SPARE 20/1 33 34 - r 2568 M --- SPARE 20/1 35 36 -• ' 2568 M -- 17.3 M 1321 20/3 37 38 2011 SPARE •-- M ' 1321 - 39 40 20/1 SPARE - M ' 1321 - 41 42 20/1 SPARE PHASE TOTALS: 22523 20831 21191 64545 =TOTAL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 187.5 173.5 176.5 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS: 1.25 X 6600 = 8250 VA C=CONTINUOUS LOADS, OTHER 1.25 X 0 = 0 VA M=MOTOR LOADS (INCL LGST): 1.00 X 56145 = 56145 VA LARGEST, VA: 0.25 X 0 = 0 VA R=RECEPTACLES: 1ST 10K: 1.00 X 1800 = 1800 VA BALANCE: 0.50 X 0 = 0 VA K=KITCHEN LOADS: OTY: 0 1.00 X 0 = 0 VA N=NONCONTINUOUS LOADS, OTHER: 1.00 X 0 = 0 VA NOTES: (P=PANEL. INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 66195 VA = 183.7 AMPERES A REVIE'A FJCj COMPLIANCE L^J!TI-I L No2; 7t, - EC. 1 I i iI City of Tukwila i L3UILDING DIVISION I PANELBOARD SCHEDULE SCALE 1 Jollibee CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION 81DS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 1 PLILOUP1 2 I 4 E. KATELLA AVENUE ANAHEIM. CALIFORNIA 22805 P (714) 383d835 F(714) 385.1034 w oopl nOYaPcan STAMP NGypF Pow PRD.A, p YIAsH �G�q cam, 0 4) 34218 `toisskvc. ��`t �ss/�NAL1EENc, E%P. O3/18/D PROJECT NAME/ADDRESS: Joflibss TUKWILA, SPACE WESTFIELD 1374 SOUTHCENTER TUKWILA, WA 372 & 368 LEVEL 1 SOUTHCENTER MALL WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE Qf 053119 CORPORATE REVISIONS 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL Qs 071119 MECHANICAL CORRECTIONS 0 ELECTRICAL CORRECTIONS t43 080919 ELECTRICAL CORRECTIONS A 031620 ADDENDUM 1 JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT PANEL SCHEDULE SHEET NO E-600 t,o0-052-cl m 9 6 2 C 6 8 0 7 6 10 f- FINISHED FLOOR lid F COUNG H 0 3 11 0 0 n 0 F.E.C. SUPPLIED AND INSTALLED ANSUL R-102 STORAGE TANK WITH ENCLOSURE AND MICROSWITCH. ELECTRICAL CONTRACTOR SUPPUED AND INSTALLED 4° OCTAGONAL JUNCTION BOX WITH 1/2"0 EMPTY E.M.T. TO EXTEND TO +12" ABOVE FINISHED CEILING. F.E.C. SUPPUED AND INSTALLED FLUSH MOUNTED MANUAL PULL DEVICE. F.E.C. SUPPUED AND INSTALLED CONDUIT AND PULL CABLES. F.E.C. SUPPUED AND INSTALLED WET CHEMICAL LINE FROM ENCLOSURE TO EXHAUST H000 PLENUM AND COOKING EQUIPMENT BELOW EXHAUST H000. ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED CONDUIT AND WIRING. ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED JUNCTION BOX. ELECTRICAL CONTRACTOR SUPPUED WIRING TO EXTEND TO BUILDING ALARM SYSTEM. ELECTRICAL CONTRACTOR SUPPLIED WIRING TO EXTEND TO POWER SOURCE. 10 F.E.C. SUPPUED MANUAL RESET RELAY TO BE INSTALLED BY ELECTRICAL CONTRACTOR. F.E.C. SUPPLIED GAS SOLENOID VALVE TO BE INSTALLED BY PLUMBING CONTRACTOR. ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED CONTACTORS (SHALL SHUT-OFF ALL ELECTRICAL DEVICES LOCATED UNDER THE EXHAUST HOOD). 13 ELECTRICAL CONTRACTOR SUPPUED AND INSTALLED ON/OFF POWER SWITCH. FIRE SUPPRESSION SYSTEM DETAIL 2 NOTE: PROVIDE ENCLOSURE TO MATCH WALL RATING IF PANEL OCCURS IN FIRE RATED WALL. CONTRACTOR SHALL FIELD VERIFY WITH ALL LOCATIONS. STEEL STUD BUILDING STRUCTURE ENGRAVED NAMEPLATE ON FRONT PANEL TYPEWRITTEN CIRCUIT DIRECTORY LOCATED ON INSIDE FACE OF DOOR HINGED, LOCKABLE AND FLAT DOOR FLUSH LOCK HANDLE AND MECHANISM BOLT TO STRUCTURE, BOTH SIDES, WITH 1/4" DIAMETER BOLTS, THREE PER SIDE AND FRAME , AS REQUIRED r r L J 120V SOLENOID NTS INCOMING POWER 120V. NHL 1 PH. 4 � `--A COIL - SERVICE / SWITCH ( TEMPERATURE CONTROL L (PENN MODEL # A19BBC-2) r J 1- I COIL 8 VALVE BLOWER (SPORLAN MODEL FAN(S) MOTOR #MKC1 & EBS130) - r TERMINAL BOX ON COIL 1 PILOT LIGHT& SWITCH 0 LIGHT INCOMING POWER 230/208V. EOHZ.1 PH. L1 L2 Esia I 1 EVAP COIL FUSED DISCONNECT SWITCH BY ELECTRICIAN 2P-30AS-15AF ELECTRICAL BOX ON EVAP COIL. COORDINATE FINAL CONNECTIONS INCLUDING MEANS FOR DISCONNEC W 'JFO 1 WITH REFRIGERATION I GOMPLI EVIEEVIE F. TM f INSTALLER. I NFQA 7C - NEC OBy O1 Tukwila BUILDING DIVISION RECESSED MOUNTING PANEL 4 COOLER EVAPORATOR COIL 3 FREEZER EVAPORATOR COIL 1 %Wks CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 1# PLUIAPGROUP 914 E. KATELLA AVENUE ANAHEIM. CALIFORNIA 92805 P ITIM 3554535 F(714) 390.1534 IFFITO IPONPW1 STAMP ot p,R E1 A. p< Q. 1 Cd W A Sy 4, ,.0 o ,y 34218 O �Q ��JSONALTLENikc �� EXP. 03/19/21 PROJECT NAME/ADDRESS: Joflibn TUKWILA, SPACE WESTFIELD 1374 SOUTHCENTER TUKWILA, WA 372 & 368 LEVEL 1 SOUTHCENTER MALL WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE QQ 053119 CORPORATE REVISIONS 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL A 071119 MECHANICAL CORRECTIONS A 072419 ELECTRICAL CORRECTIONS A 080919 ELECTRICAL CORRECTIONS A 031620 ADDENDUM 1 JOB NUMBER MEP # 1901089 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT ELECTRICAL DETAILS SHEET NO E-700 NTS NTS NTS €c(9- cjcj Lighting Summary LTG -SUM 2015 Washington State Energy Code CompRance Forme for Commercial Buid'ngs Icludig R2, R3, R4 over 3 stories and a RI Revered Nov 2017 Project Info Compliance !armada not requires to patuse. Insnuctiod endca(cWdag cells ens write- protected.Applicant Project Tole: JOLLIEEETUINNLA Dale 9/6/2019 Applicant information. HaidecmfectiMvmel/mfor lndviduWWYMbcan respond to Inquiries about compasrcetam lydormelbnfronded. For Budding Deparonent Use Co"W1Y Name: PLUMP GROUP Company Address: 914 EKATELLA AVE ANAHEM, CA, 92805 Applicant Nana: ADEL POURBHl4RF Krone: 714.385.1835 Applicant Email: APOURSHARF@PBCA.COM 4ae�e Project Description No Lghting Scope ❑ New Building ❑ Addenn t7 Alteration • include PROJ-StAAtont (included in envelope forms ,workbook) with lighingcomp/anceforms Interior Lighting System Description &Yiehydescribe interiorligmng system type err features. R Interior Lighting Plans Included Interior Lighting Power Allowance Method ❑ Building Area Method (y] Space -by -space Method Selectmetcdusedin prefect. interior Lighting Controls SMedmethod of compliance falfpMhp codrols. Exception 5 Lunhdre Leval Conhds (LLLC) p Al C40S.2. i-c4os. 25 Lighth9Codmb • C405.2 L'gMhg ■ Additional ETc!encY Package0pr C4064 Enhanced DOW Lighting Controls Tocompywith C40S4, no less Man 90%d thetotalinaaVadirtehorlgfingpawrshWfconnlywithihe requlredccdmlaperC406.4. Dwelling Unit Interior Lighting Permnernyinadiedirdabrlgldn96A1ures in dtel8ngunlla complywMh: 4) No Dealing 0 C4052 m thru C405.5 Caieresl Lightingand Controls d LM Units 0 C408.3 He Efficacy L'ghthg O R404.1 Resident. High Efficacy Lghtrg. Nei ling LSIighdngcempibswi#i WSECReadnf/al provisions inlieu of WSEC Conmercldprovisions. Exterior Lighting Description &fsllyd ascribe extenorIghung type and features. System system Included • Exterior Lighting Pans Building Additions Wert* Sectln c502.2.6 for additions/ requirements . Compliance Method Interior lighting &terbr leant Lighting systems n add4icn area comply with a applicable provisions as a stand alone new constructionproject ❑ ■ Lightingsystems Ohtlrsystems ton are combined w Maisano o demonstrate compliance■ 0 Additionlscombinedwlth elating: ForintWorlghdngprgsds, Include new ♦exiatirg-orsmahidenbrlght gfixhne swage (nPreposes Lighting Wafegetabre MLTO-INf-BLDorLTG-MT-SPACETa n. For exterior llghthgproyede MOM, wdtagein Proposed Traders; eand RopoaedNon-TdedebbLigleingWsfrgetables in LTO-DRWm. Lighting, Motor, 2015 Washhgtn State Energy and Electrical Code Comp/ante Permit Checklist, Pg. 2 LTG-CHK and al R7 Revised Nov 2017 Forme for Commercial Buidngs hckid ha R2 R3, R4 over 3 stories Project Title: JOLL,BEETUIIMILA pate 8/6/2019 The felow ing nfonnaton is necessary to check enema application for compliance w ith he lighting. motor. and electrical requirements h the Applicability (Winona) Code Section Component Onpliance!nformation required n permit documents Location In Documents Biding Department Notes NA C405.2.5 - lam 3 Hotel/motel guest rooms indicate method of automatic coned - vacancy or cpUve key contd of all luminaires luelres and sw itched receptacles n guest room SHEET 5400 NA C405.2.5 - tan 4 Supplemental task lightingcont'Wing,d indicate method and beaten of automatic shut -elf vacancy for supplemental task 'Wing, inducingunder-shelf or under -cabinet Ighthg SHEET 6400 NA C405.2.5 - 5 Lighting for nor- visual applications ideate on pans elgble non -visual lighting pplcatio s, include sq. ft area of each lighting coned zone; SHEET E400 ideate on plans that non -visual lightingare controlled independently tram both general area lighting and other lghtng applications wahh the same space: SLEET 6400 Ram Indicate method of manual Sonilg control and apple able automatic Ightng coned SHEET 6400 C405.2.5 - Items Ligin9 equipment far lade or demonstration Indicate on plans that lighting equipment for sale or tlanwnstratn am contrclled independently from both general Ightng lighting Mn the 811�T G400 area and other applications w saneNA space, indicate method or manual Ightng control and welt &le .._-... automatic Ightng control SHEET FA00 Yea C4052.5- Item 7 Means of egress Ightng Identify on plans egress fkures that function as both normal aid emergency mans d egress domination: SHEET 6400 Rovkle calulaton of lighting power density of total egress lighting; SIC rAOa E total egress lighting power danty s greater than 0.02 Wes. ft. WMicate on plans egress Mures requiring automatic shut- ell during unoccupied weds; SHEET 6400 Indicate method d aulflc shut -elf contrd -steer 6400 NA C405.2.7 Bxtembr Ightng controlspemwtgtelakg Idicateon exterior lighting plans and fklure schedules the automatic Ightng cntrd method, coned sequence, and locations served; STET 5100 For buildig facade and landscape lighting. indicate automatic controls shut elf lighting as a function of dawntuak Med time; SHEET BIT 6100 For al other exterior lighting, hdeate automate cntrob shut elf leMhg as a function of available daylight: Include control sequence that also reduces Ightng pow er by at least 30% between 12.14am, or Trani hour after dosing to 1 how before penhg, or based upon motion sensor SHER 15100 NA C405.5.1 Exterior buildingFor grounds Ightng controls bolding grounds flxures greater Than 100w ans. tide ate on plans whethe tenures have efficacy greater than 80 lumens or: are controlled by motion sensor, or are ex errant Ighthg per C405.52 SHEET Ea00 Yes C405.2.5 (fated after C405.2.7) Area controls Muter tontrd tones Indicate locationrasters) of ster coned swtch(es) mended to contra mult'ple hdependent sw itches; crook breaker may net be used as anaster contra sw&oh; SHEET 6100 sw and tireut power 14N Very that no 20anp clout omlroled by a single swtcha contrd isloaded beyond 80% SHEET E400automatic ADDITIONAL EFFICIENCY PACKAGE OPTION -ENHANCED DIGITAL LIGHTING CONTROLS NA C908.a Enhanced dgee fighting controls To tartly w kh additional efficiency pac ageoption, Indicate on plans al nterior Ightng Rehires that are hdivldually addressed and provided w kh conbnuous dimming, or exception taken: SHEET 6100 Include calculation of percent total Metaled nterior lighting power that Is eonfgured with required enhanced lighting control functions (min 90% to cape w M addilbnd et fklency package option) SHEET G00 Lighting Summary, cont. LTG -SUM 2015 Westin ton State Energy Code Complance Forms tor Corrmercal Bolan Inebd'np R2, R3, R4 aver 3 stories and al R1 Reviled Nov 2017 Project Tide: JOLLIBEETUKWILA We 8/6/2019 Change of Space Use ❑ Bating Interbrlotting systems inareas under -going a change in space use are upgraded to coney w Xh LPAs for the new space types per Tables C405.4.2(1) orC405.4.2(2). kee er,Interiorspacesrequirng LPD upgrade to the tuned Code In Proposed Lighting Waaagefable /n LTG 4NT-8L D a LTG4NTSPACE hum. Interior and Exterior Lighting Alterations Selected Lighting PoaerandLighting Control elements Metapptyro the scope of the retrofit project. if target, includes@ continetindapacesi.terelesathan 50% of the existingflxtussare replaced in some spaces. and 50%ormore of e fixturesfixturesam roplacedin others. then provide separate lighting power conplience forms forth. Moretrohf confirms. Spaces undergoing the sane type d',gammay becombinedlNom, rghtingpowerconpllance form. Refero Section C503.8br addition/ reguiremens. All alteration llgMlnpentroa shell be commissioned perC408.3. Lighting Power Wrier lighting Psrldngarea Stenorighting 5096orreproof exletingare replaced 0 p ■ Las than 50%ofexstln arereplaced g❑ • • Lane androrballast replacenentonly - exeVng total adagenotinereased • • ■ r� ormorereplaced- Total lightygpower ofnew+ existing -to -remain fixtures shascontplywith total LPA per Section C405.4.2end C405.52. Include now+ sxlstM Wedgesb!em 17( LTG-INT.8LD.LTG•7NT-SPACEorLTG-Tkrmi. ananrtxtursaln Pmpoaed[lpllvg Lap then 50%replaced- Total lightly paten ol new + existing -to -remain haloes exceedte tots/ lighting poser prloroaherallon. Include new+existinp+. tomuMe nMumsMProposed Wattage table in LTG•INT431.0.LTG-INT•SPACEorLTG-EXThrm. SO% threshold applies to number olfurdnairesfor insdorspecesandparking garages, and total instal/edentate. t rexbdorlundnetea Lighting Controls hterbr lighting Parldnp garage &tenor lighting New w king installed to serve added fixtures andbrfixtures rebooted new circuit(s) CI • ■ New or moved baffling panel • • ■ Interior space is reconfigured- 'unlearn unchanged or relocated onty ■ New ofringorcircuit- For intoner Ugh imp. provide rp ersdmanualcntrolsper C405.2.3. occupancy sensorcontrdsper C405.2.!. *light responsive contobpe C405.2.4 and applicationsped&Ilphlbg controls perC405.2.5. For extenorlightng, provderequired controls per C405.2.7. New or moved panel. Provide alappl able!/ghfngcmtnlses noted torNew Wiring and automatic tmeswiohcontrols perC403.2.2. Reconfigured interior space• Provideelf required lighting cnfmasthaspplytoa new Interior specs. Appl/cetinspecMc IghMgconbolprovlebnsperC405.2.5 do not epprgic reconfigured spaces Nochangetare being made to •the interior orerternorIIghWpg systems and<naring space uses and con/ igurationare not changed. Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG-CHK 2015 Wash hpton State Energy Code Complaints Forms for Cammerclal BUNhgs including R2, R3, R4 own 3 stabs and a R1 Revised Nov 2017 Project Title: JOLLIIIETUKWLA ICate 8/6/2019 The fellow hg hfarmalbn is necessary tochecks' pen. application for camplineew kin he fighting, nxxor, end electrical requirements h he Applcabily (Yes.no,na) Code Section Component Compliancenfomslion regWred in paint documents Location In Documents Bidding Department Notes INTERIOR LIGHTING POWER & EFFICACY Yes 040&enhance4.1 C405.4.2 _ Totalconnected Interior lighting power Include all Winates In lighting fkbre schedule; Indicate fixture types, lamps. ballasts. and manufacturers rated watt per fixture; BIET 6400 Merdy spaces eigble for Ightng power exeption on plans and h enhance forms; hdeata the exception applied; sire FAOD Identify lighting eguprnent elgble for Ightng pow er exemption h falure schedule and in deplane toms; indicate the exception poled; SHEET MOO ideate thal exempt Ighthg equOmen! is in addebn to general area Ightng and is controlled hdepnanly &� moo Yes G06.3 Brit spa Indicate location of exit signs nan tts pland rated waper fixture In Ightng facture schedule (maximum 5 watts per side) SHEET MOO NA C405.1 Lighting in dw Nanglighting units -lamp efficacy if high efficacy exception is ppaed to pnronentlY instaled fixtures n dw ailing units, indicate h lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures w th high efficacy lamps in project (min 75% to copy w kin exception). SHEET 6400 Interior Lighting Power Calculation - Indicate compliance path taken C405.4.21 Bolding Area Method Complete requked cnplence fans -proposed w adage per buWhg area does net exceed maximum allowed wattage per buWhg area: identify locations of bolding areas on pans SHEET 6400 Yes CA05.4.22 Space -Sy -Space Infatad Complete reflect cmplance forms -total proposed wattage does not exceed maximum Sowed wattage; identify locations of space types n plans, hcudirg reran dsplay areas, lobby art & exhbl display areas, and ceing heghts as applicable & Err BOO ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY Yes C406.3 Reduced lightingdemonstrate power density To cclrply with addltbnal efficiency package peon, in copiance forms that blaI connected harbr lighting wattage iskn 25% less ban the total max Mum Sowed lighting wattage via BuMdirg Area Method or Space -By -Space Method SHT13400 E NA 0408.3 Reduced IgMig power d ,s I dw ding For project w ills dw dlkg units, to comply w kh eddSonal efcsncy package peon indices in fighting fixtureschedule 1 lanes n interior fnures have efficacy rating of BO lumens per wanes more. Calculate percentage of fixtures w In lanps that have he of bacy rang (corn 95470 to comply w ith open) SHEET MOO amp unefficacy EXTERIOR LIGHTING POWER & EFFICACY NA G08.5.2 Total connected exterior Ighthg Power Include al lunwnaires in lahthg fkure schedule; indicate fkure types, lamps, balasts. and manufacturers rated was per Nature SHEET 6400 identify exterior applications eleble for horning power exemption on plans aid in compliance forms; iMkae exception *Pied: 00 M00 hdicab that exempt exterior lighting is emanated independently from non-exempt exterior lighting; include exception clamed for each fixture or group of fixtures under eaceptbn category SHEET 6400 NA Table C405.5.2(1) Bernortghtngzne Indicate bolding exterior Ightng zone as defined by theIIET AEU SE400 NA C405.5.1 Fxterbr boldingFor grounds Ightng binding grounds fixtures rated at greater than 100w acts that based tide Tamp SHEET MOO are complying on efficacy, ate rated efficacy (n umens per watt) h fixture schedule NA 0405.5.2 &ter'xx Ightng power calculations Compete requked carpliance form- premed wattage for extarldr lighting plus baseske Slowed does not exceed maxhnumalowed SHEET GOO Interior Lighting - Space -By -Space Method LTG-INT-SPACE 2015 Washington State Energy Code Commence Forma for Commerce' Bullrings hdudinp R2. R3. R4 over 3 abries and al R1 Revised Nov 2017 Project Title: JOLUBEE TIIKWLA Date 8/6/2019 Cakulatlon Area MDIR. O New Construction 0 Addiemstanda- ore 0 Addt on sting 0 Our 0 Spaces here<50%of 0 Spaces herez50%d 0 Spaces w herethe use bnw,ares are replaced 4minaires arerepaced S chengig (C505) For Bolding Department Use LPA Calculation Type • standard 0 Addeonal Efficiency PackageOption 017ear C4013.3 Reduced Interior Lghthg Power Tocamp/ywlfh C4063, the PrcposedtPD Shell be25%lower than The Target LPA Relents C408.3for additional requirements. Use Notel Maximum Allowed Lighting Wattage NO�E1 Location (plan It, room M) Space Type Caking HeghtNOTE2 Dose Intro' Area In ft' Akowed Watts per ff Hoes Allayed (watts/fir x area) VJTCHEJ Food preparation 939 0. t)C EE! MANAGERS CFFCE ON ice: Ewlceed 52 0. 44 CC 4E Lobby ArVFxhibi Dlaplay Allow once from LTGM-DtSRAY InTE8 Total Area R etai Display 891 LTGNr-CISRAY Allowed Watts Alum once from 710 Proposed Lighting WattageNO1Ea Locaton (plan M. room#) RXIUeDescriptkon NdrE460 Nunter of Fkuras Wan/ FkureNOOET Woes Reposed KITCHEN LEDA/AE24113AR 42 W 13 42 596 MANAGERS CFFICE LEDB/BE 2'2TEAR25W 2 25 50 Proposed Retal Ds lay Lghting Iran LTGINT•OSRAY rota/Proposed Watts magnet exceed Total Mowed Watts for lighting Total Propoe.d Waite 596 Interior Lighting Power Allowance COMPLIES Lighting, Motor, and Electrical Permit Checklist, Pg. 4 2015 Washington Stab Energy Code Conplance Farms for Conesrels Bolding' including R2, R3, R4 ever 3 stories and al RI LTG-CHK Rooked Nov 2017 JOLUEEE TINOMLA Date B/6/2019 The fdbw ng informationis necessary bcheck a game pplbalbn for compliance w th the lighting, motor, and electrical requirements in the Applkabilty (yes,no,ne) Code Section Component Compliance information required in permit documents Location in Documents Bolding Department Notes LIGHTING ALTERATIONS Yes C503.6 Interior and parking garage holding fixture alteratons Mere 2 So% of existing lumhakes ii interior space(s) or parkhg garage are replaced; ideate compliance path (bolding area or space -by -space method); include al new and exbthg- to-remainlumnatesincompliance form (LTGM-BLD or LTG NT-SPA CB; indicate proposed Ighthg wattage does not exceed nsxmum allow ed per compliance path SHEET 6100 Were <50% of existing luminaires In Interior space(s) er parking garage are replaced: indicate total ex lithe Ighting w atbge in each space prior to alteration; Include all new and existing-toremeh luminaires in LTGINTSPACEfornz hdkate proposed total lightag w attage in alteration area does not exceed iota! existing lighting w attage prior to alteration &IEr 6100 NA C503.8 Exterior Ighthg fkure dleralism Where 2 50% of existing exterior thing w allege is replaced; Studs all new end sxbtng-toremain luminaires in LTGEXT form; indicate proposed total exterior lighting wattage does not exceed max Mum slowed MOO Were <50%d ex bring exterior Ightng wadage is replaced: indoate total math]Ightng g p wattage pnor to alteration; include al new and existing -to -remain luminaires h LTG -Ea form: indicate proposed total exterior Ighthg w attage does not exceed total exetr e w attage prior to Sheraton SHEET E40o Yes C503.6 Interior lighting w.. alterations Mere new w iring s instated to serve new interior luminaires and /or luminaires are relocated boa new clrcult indicate controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C4052.1); daylight responsive (C405.2.3); (C4052.4); specific appkatbn (C4052.5); exit sgns (C405.3) SHEET E40 SHEET NA C503.8 Exterior lighting alterations Sawa new w king b installed to serve new exterior luminates and /or luminaires are relocated tonew circuit Indicate exterior Ighthg controls are provided (C405.27) SHEET 6400 Yes C503.6 Lighting panel akerSons Mere a new Ightng panel is installed a an ex inky panel is moved (al new' raceway and conductor w iring); indicate lighting controls are provided (as applicable) • same provisions as w ring iterations; tine sw kh contrds and manual tight reductbn controls (C405.2.2) SHEET 6400 Yeas (503.6 anterior space recce gurabn Were interior space(s) Is reconf loured (permanently installed walls or cellhg•heght partition); indicate lighting controls are provided (as applicable)- same provisions es lighting pans alterations 6400 Yes C504.2 Lighting repairs kleney existing uminares being upgraded with but aid for hal alreplacemenL imitate fkure alteration does net ncrease ex sing fixture w atop' stir 6100 Yes C5051 Change of space use Mondry spaces on plans w here the bulling area type or pace use types being changed Iran one type to another per Tables C405.42(1) a (2) sneer 6400 Indicate canplence path (buldlnp area or space•byspace method); include al new and exbng-o-remain lu mil aims In compliance form (LTG-M•BLD or LTGM•SPACEn indicate prpoaed Ightng wattage dose not exceed maximum abw ed percompllence path SHEET BA00 RECEPTACLES Yes C405.10 Cntrdled receptacles Identify all controlled and uncontrolled receptacles on electrical in each n w hich they are required: inc lade SHEET B400 plans pace receptacle configuration such as spacing g beecontr.. and uncontrolled. duplex devices. eto: Indicate on plans whether the frothed of auomdk coned tor each controlled receptacle zone is by occupant sensor or programmable tine -of -day control SHEET 6100 Lighting, Motor, and Electrical Permit Checklist, Pg. 1 2015 Washington State Energy Code Compliance Fonns for Conmercial BuWhgs hcudhg R2, R3, R4 over 3 stories and at R1 LTG-CHK Revised Nov 2017 Project Title: JOLUBEETUKWLA Date 8/6/2019 The folow hg Information 's necessary to check perms application for comp Hance w ith the lighting. motor, and electrical requiernents in he Washington State Energy Code, Commercial Rovabns. Applicabiy (yes !nuns) Code Section Component Compliance nfomadon required in permit documanb Laeation in Documents Bulling Department Notes LIGHTING CONTROLS Yes C40&2 Lighting controls. general For at lighting fixtures, indicate Ightng control method on plans for spaces and lighting zone(.) served, or sensation taken Gs00 Yes G05.2 Luminaire level Nghtlnp controls (LLLC) hdoate on plans alfkures provided will LLLC it lieu of C405.2 lighting controls; provdedescrpecn of control capalies and performance parameters SHEET 6400 NAunits ri1051 Lighting In dw For pamanntty installed Ightng fixtures hi dw Sang unt. indicate Ighling control method on plans fa spaces and lighting zones) served, or demonstrate compliance w di high efficacy exception ding Yen C405.23 G05.21.1 CA05.22.2 C406.24 0405.25 Manual controls hdkate on plans the method or manual Ightng control (whether combined w in occupancy sensor. automatic lght reduction. daylight responsive or spec kk application contras). beaten of manual tontrd device and area or spec Inc apical. It serves SHEET E400 Yes C405.22.1 C405.222 C405.2.3 Manual interior light reduction ccntrds hdkate on plan which method of manual 50%IigMing bad reductions provided, or w tether lighting Iced s reduced via occupancy sensors or daylight response. centrals SHEET 6400 Yes G105.2.2 Method of automatic shut-off ccMrd hdkate on plan the method of automatic shut -elf control during unoccupied palods (occupancy sear, tine switch or ifyisl timer sw itch) for alllghtng zones; SHEET 6400 Nicole locations w hero aubmatc shutoff Is provided by other methods (occupancy sensor or digitaltimer taw Itch) or w Nch Ins switch tontrd excetnbn applies SHEET E400 Yes C105.2,1 0405,2.1.1 Occupancy sensor controls Whoa* on plans the spaces served by occupancy sensors; SHEET 6400 Indbefew hither occupancy sensor controls are configured to be maivaFon, aubmatb 50%-on, or serve a space asp be for automatic 100%-ce per exemption SHEET 6400 -- NA C405.2.1.2 Occupancy sensor controls • warehouses Indicate. slew rya and open areas In w arehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% SHEET 6400 Yes CAOS.22.1 Automatic tine law Itch contras hdbate locations of override sw aches n and d the Ightng zone(s) served. hcude area sq. ft me 64D0 C90S.2B Dplal Imam sw itch Indicate digital tkrer switch control heludes: manual on/off. ale delay, audios and visual Wheaten d impending tanrout SHEET 6400 NA C905.2.4.2 C9052.4.3 Daylight zones SMdghtand tpIgM indicate primary and secondary sidelight daylght zone areas on pens, include sq. ft; SHEET 5400 hdbaetdptght daylight zone areas an plans, Include sq. ft.; SHEET 5400 Forsmelvertical fenestration assembles (rough opening less then 10 percent of pinery daylight zone) wheredaylight responsive controls are not required, provide fenestration area b daytght sane ealedabn(s) SHEET 6400 NA CA05.24 Daylight responsive contrds hdkate on plans Nghing zone(s) served by daylight responsive controls; SHEET 6400 Identify s1delgM and bpleht daylight zones that are not provided w tlh daylight sensing cmtrds and the exceptbn(s) SHEET 6400 thatppty, hdbatenplans the lighting load reduction method - continuous diming. or stepped dimming that provides at least SHEET 6400 two even steps bate en 0%-100% of rated pow er; hdkate that daylight sensing controls weconfigured to carpingly shut off al controlled Ighb in the Ighthg zone SHEET FA00 NA C405.2.5 Additional contrds - Specific pploatbn Ightng contrds identify spaces and lighting fixtures n plans that require specific application lighting controls per the section MEET 6100 NA C405.25 • terns l&2 Display and accent lighting hdkate on plans that display aid accent Ighthg, and display ease Ilati g re cntrdled independently Iran both general area lighting and other Pahtlng applications w ithh the same space; 6000 hales. manual and albnatic lighting cntrd method Lighting, Motor, and Electrical Permit Checklist, Pg. 5 2015 Washbatn State Energy Code Conpsnce Forms for Camera. ercs Bolding. including la. R3, R4 over 3 stories and all R7 LTG-CHK Revised Nov 2017 JOLUBETUI4MLA Cate 8/6/2019 The fellowhg Mamatbn is necessary ocheck a permit pplical i for compliancew Rh the homing. motor. and electric Sr equiamnb in he Appbablty (yes,nora) Code Section Component Conptence hlornain required In part documents Location in Documents Buldhg Department Notes MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION NA C40S5 Beet bat transformers Include electrical transformer schedule n etectrcal plans; Indcate transform sae, efficiency. or exception take SHEET 6400 C005.7 Ow ding ink ebctrical energyhas consumption indicate on electrical plans that each dwsling unit in Group R2NA a separate electrical energy meter SHEET 6400 NA C4058 Bectrb moor efficiency Include ail rnotas, including fractional hp moors, it electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency. or eicepton applied SHEET 6400 NA C405.9.1 Bevabr Baba For kirma'ses in each elevator cab. provide calculated average efficacy of combined tortures that indicates efficacy is not less than 35 linens per watt: __ ...__.. SHEET 1400 forel_.._ s Indicate rated wails pa cfm la kvda cab ventilation Ina do net exceed 0.33wats per cfm; &MEET 6100 Indicate automatic contrds That de-energae lghthg and vendetta fans when elevator is stopped and unoccupied for a period of 15nnutes or nitre SHET 6400 NA G05.9.2 Escalators and moving wens indicate escalates campy wan ASh£A17.1(CSA B44: SHEET 6400 automate controls are eon guree reduce operational speed tome mnnum permitted w hen not h use NA G05.9.3 Regenerativedrive Indtae ail one-way dawn or reversble escalators are provided w mh a varable,requency regenerative drive SHEET E400 DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (ex) Yes 0408.3 Scored electrical power and Ightng systems cammsskonag Indicate that al electrical systems (receptacles. transformers, moors, vertical and horizon's/ transportation) for wheh the 1eruEC requires control functions and / or cnfgurabon to perform speckle functions are required to be commissioned: SHEET &00 Mere total bolding lighting Iced 1 > 20 kW or w here total lighting bad d luminaires ',goring daylight sensing and f or occupancy contd > 10 kW, Skate that all ariomabc Whig tontrd systems are required to be commissioned: or provide building lighting Dew er calculation demonstrating e(gbiky for exception: SHEET 6/00 Yes C405.13 C408.1.1 C408.1.2 C408.1.4.2 C103.6 Comntnsbnig requirements construction docurenb Wit ate On requirements h plans and specifications for al applicable electrical and IigMhg control systems per C408; SHEET 6/00 Wide general summary w Rh at mnhum keen 1 thru 4 of the Co plan per C408.1.2 including: narrative desorption of activities, reep0nsh1tln of the Ck team schedule of activities incudng verlkabn of project close out documentation per C103.6, and end conflict interest plan Of required): SHEET 15400 Include in general summary that a Ca project report or Ccopence Oeckst (Flours C408.1.42) shall becarpaled by the Certified On Rdessbnal and provided to the taw ner prior to the final electrical inspection MEET E400 Yes C408.3.1 Functional performance tesing criteria Identify n plans and specticabns the Intended operation of al equipment and contrds during all modes of operation, including Merfaehg between new and existing -to -remain systems SHEET 6400 PROJECT CLOSE OUT DOCUMENTATION Yes C103.8.3 Rgeet dose out documentation requirements Indicae rioters MS prefect close out documentation is required including WSEC lehkng compliance fors and calculatons that document al inter'ror and exterior 'Ohba area and/ or surface types, lighting power allow antes and installed densces SHEET 6400 no Is selected for any clue on, provide explanation: 00NFPA P E NC ? j D-E4.r2C C City of Tukwila BUILDING DIVISION End of Lighting, Motor & Transformer Permit Documents Checklist INDOOR LIGHTING COMPLIANCE SCALE: NONE 1 CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4 # PLOUP 914 E. KATELLA AVENUE ANAHEIM. CALIFORNIA 92805 P1711) 386.183E F(714) 30-1/34 wAx kareme.wn STAMP ,, � p,RaA.p< S. G�1 WASy; et, eilS 0 SI z 9 34218 p IC' ccf 4Q LTEL0\a4 IXP. U3/19/21 PROJECT NAME/ADDRESS: Joflibn SPACE WESTFIELD 1374 TUKWILA, TUKWILA, SOUTHCENTER 372 SOUTHCENTER WA & 368 LEVEL 1 MALL WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE A 053119 CORPORATE REVISIONS 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL -4\ 071119 MECHANICAL CORRECTIONS 072419 ELECTRICAL CORRECTIONS 4 080919 ELECTRICAL CORRECTIONS /5\ 031620 ADDENDUM 1 JOB NUMBER MEP # 1901089 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT INDOOR COMPLIANCE LIGHTING SHEET NO E800 GENERAL NOTES LEGEND AND NOTES LIGHTING FIXTURE SCHEDULE 1. BEFORE SUBMITTING BID, THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FULLY ACQUAINT HIMSELF WITH THE JOB CONDITION, SERVICE REQUIREMENTS BY UTILITY COMPANY AND CONNECTIONS, AND OTHER CONDITIONS INCLUDING TRANSFORMER PAD, ALL NECESSARY PULL BOXES, JUNCTION BOXES, SIZE AND NUMBER OF CONDUITS AND CONDUCTORS. CONDUIT FITTINGS. SERVICE COMPONENTS, PANELBOARDS, ETC., WHETHER . SHOWN ON DRAWINGS OR NOT, TO MAKE A COMPLETE AND OPERABLE ELECTRICAL SYSTEM WITHOUT ADDITIONAL COST TO OWNER. 2. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL LOCAL LAWS• RULES AND REGULATIONS OF ALL LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION. IN CASE OF CONFLICT BETWEEN REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY. FOLLOW THE LOCAL LAWS, RULES AND REGULATIONS FOR ANY CONFLICTS BETWEEN THE CONTRACT DRAWINGS AND THE LAWS, RULES AND REGULATION. 3. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND ARRANGE ALL REQUIRED INSPECTIONS FOR THE EXECUTION OF THE WORK UNDER THIS CONTRACT. HE SHALL FURNISH ALL INSTRUMENTS AND PERFORM ALL TESTS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. HE SHALL ALSO CORRECT ALL FAILURES AND REPLACE ANY DAMAGED PORTIONS OF THE WORK RESULTING FROM THESE TESTS. THE COST OF THE FOREGOING ITEMS SHALL BE PAID BY THE CONTRACTOR. 4. THE CONTRACTOR SHALL COORDINATE CLOSELY WITH THE OWNER AND OTHER TRADES FOR ALL PHASES AND SCHEDULING OF WORK, AND AUTHORIZED IN WRITING BY THE OWNER AT LEAST ONE WEEK PRIOR TO THE EXECUTION OF ANY WORK. 5. ALL MATERIAL FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE NEW AND UL LISTED, FREE FROM ALL DEFECTS. AND SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE OF THE WORK. 6. THE ELECTRICAL DRAWINGS, CONDUIT RUNS, WIRING AND ELECTRICAL INFORMATION ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE THE LOCATION OF EQUIPMENT OR OUTLETS. 7. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS OF ALL LIGHTING FIXTURES, CEILING MOUNTED OUTLETS AND EQUIPMENT. 8. ALL RECEPTACLES AND OUTLET MOUNTING HEIGHTS AND EXACT LOCATION SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS ELEVATIONS PRIOR TO ROUGH -IN WORK. 9. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY TYPES OF CEILING SYSTEMS AND TO FURNISH APPROVED LIGHTING FIXTURES OF THE TYPE REQUIRED FOR MOUNTING IN RELATED CEILINGS. FIXTURES SHALL BE COMPLETE WITH NECESSARY MOUNTING HARDWARE AND ACCESSORIES. FIXTURES LOCATED IN DAMP OR WET LOCATIONS SHALL BE LABELED FOR USE IN SUCH LOCATIONS. 10. ALL RECESSED LIGHTING FIXTURES, SPEAKERS, PANELBOARDS, SWITCHES, ETC., MOUNTED IN FIRE RATED STRUCTURES SHALL BE ENCLOSED WITH AN APPROVED ENCLOSURE CARRYING THE SAME FIRE RATING AS THE STRUCTURE. 11. ELECTRICAL OUTLETS ON OPPOSITE SIDES OF FIRE RATED WALLS AND PARTITIONS MUST BE SEPARATED BY DISTANCE OF 24 INCHES HORIZONTAL, U.B.C. 4304 OPENINGS IN FIRE RATED WALLS GREATER THAN 16 SQ. INCHES MUST BE FIRE STOPPED. 12. SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS, CEILINGS, FLOORS, ETC, TO MAINTAIN THE FIRE RATING. FURNISH AND INSTALL FIRE RATED ENCLOSURE FOR ALL EQUIPMENT PENETRATING INTO FIRE RATED ENVELOPES, SPACES ETC. 13. PORTIONS OF THE CEILING SYSTEMS MAY BE INACCESSIBLE. THEREFORE, THE CONTRACTOR SHALL STRATEGICALLY LOCATE ACCESS BOXES, ETC., WHICH SHALL BE READILY ACCESSIBLE. ALL LIGHTING FIXTURE WIRING. BALLASTS, J-BOXES, ETC. SHALL BE ACCESSIBLE FROM FIXTURE OPENING. 14. ALL WIRING AND ELECTRICAL EQUIPMENT INSTALLED FOR MECHANICAL AND PLUMBING EQUIPMENT SHALL BE IN ACCORDANCE WITH DIVISION 15 AND ASSOCIATED DRAWINGS. CONTRACTOR TO OBTAIN THE REQUIRED MECHANICAL AND PLUMBING DRAWINGS AND PROVIDE ALL EQUIPMENT, RACEWAYS, WIRING, ETC., AS INDICATED THEREON AS PROVIDED UNDER THE ELECTRICAL WORK. 15. ALL FINAL CONNECTIONS TO OWNER FURNISHED EQUIPMENT SHALL BE MADE BY THE CONTRACTOR UNLESS OTHERWISE NOTED. VERIFY ELECTRICAL CHARACTERISTICS AND U.L. LISTING PRIOR TO CONNECTION. 16. THE CONTRACTOR SHALL VERIFY THE LOAD INPUT VOLTAGE OF ALL EQUIPMENT PRIOR TO INSTALLATION. ACCEPTING ANY EQUIPMENT RESULT IN LOAD INCREASE SHALL BE THE RESPONSIBILITY OF CONTRACTOR. 17. PROVIDE AN ADDITIONAL JUNCTION BOX (SIZE AS REQUIRED) WHERE THE NUMBER OF CONDUCTORS EXCEEDS THE MAXIMUM ALLOWED FOR A GIVEN JUNCTION POINT OR OUTLET. 18. CONDUCTORS SHALL BE THHN/THWN 600 VOLT INSULATION COPPER UNLESS OTHERWISE NOTED. USE PROPER TEMPERATURE RATING OF CONDUCTORS BASED ON THE AMBIENT AIR TEMPERATURE WHERE CONDUCTORS ARE BEING USED. HIGHER AMPACITY CONDUCTORS AND LARGER RACEWAY SHALL BE PROVIDED TO OFFSET THE AMPACITY CORRECTION FACTORS AS INDICATED IN NEC TABLE 310 AND ELSEWHERE IN CODE. 19. DO ALL DRILLING, CUTTING, CHANNELING AND PATCHING REQUIRE TO ELECTRICAL WORK AND INDICATED OR HEREIN SPECIFIED. ALL HOLES, CURBS, ETC., IN FLOORS, CEILINGS AND WALLS SHALL BE PATCHED. UNLESS INDICATED OTHERWISE. PAINT ALL EXPOSED ELECTRICAL RACEWAYS, CABINETS, ENCLOSURES AND FITTINGS TO MATCH IN COLOR ADJACENT SURFACES IN FINISHED AREAS. 20. EMERGENCY LIGHTING SHALL BE PROVIDED PER U.B.C. OR LOCAL CODE AND SHALL BE DESIGN TO PROVIDE MINIMUM REQUIRE FOOTCANDLES AND LUMENS. 21. BRANCH CONTROL CIRCUITING MAY NOT BE INDICATED ON THESE PLANS. CONTRACTOR IS RESPONSIBLE TO COMPLETE THE BRANCH CIRCUIT WIRING IN ACCORDANCE WITH PLAN NOTES AND AS PERMITTED BY LATEST NATIONAL ELECTRICAL CODE (N.E.C.) AND ANY LOCAL SUPPLEMENT. CONTRACTOR SHALL SUBMIT FINISH DRAWINGS AS A PART OF SHOP DRAWING SUBMITTAL TO ARCHITECT AND AUTHORITY HAVING JURISDICTION. 22. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND SUBMITTALS FOR ELECTRICAL EQUIPMENT SHOWN ON THE PLANS AND SPECIFICATION FOR THE ENGINEERS APPROVAL. THE ENGINEER MAY REQUIRE THE CONTRACTOR TO REDO ANY WORK. WHICH WAS NOT APPROVED, OR THE ENGINEER MAY REQUIRE A CREDIT TO THE OWNER. PROVIDE A SET OF AS BUILTS AFTER THE JOB IS COMPLETED. THIS SET SHALL BE CONTINUOUSLY UPDATED DURING CONSTRUCTION PERIOD. e $3 Sm e • NOTES: WALL MOUNTED OCCUPANCY SENSOR. SINGLE POLE TOGGLE SWITCH 20 AMP, 120 V, @ 44" AFF DOUBLE POLE TOGGLE SWITCH 20 AMP, 120 V, @ 44" AFF THREE WAY SWITCH 20 AMP, 120 V, @ 44" AFF DIMMER SWITCH 1800 WATTS, 15 AMP MINIMUM, 120 V, @ 44" AFF MOTOR RATED SWITCH, HP RATED SINGLE RECEPTACLE, NEMA RATING AS NOTED DUPLEX RECEPTACLE 20 AMP, 120 V GROUNDING TYPE, @ 15" AFF CONTROLLED DUPLEX RECEPTACLE 20 AMP, 120 V GROUNDING TYPE, @ 15" AFF DUPLEX RECEPTACLE 20 AMP 120V GROUNDING TYPE, @ CEIUNG DOUBLE DUPLEX RECEPTACLE 20 AMP I20V GROUNDING TYPE, @ 15" AFF DUPLEX RECEPTACLE 20 AMP 120V GROUNDING TYPE, FLOOR MOUNTED GFCI RECEPTACLE, 20 AMP 120V GROUNDING TYPE, @ 42" AFF, U.N.O. DEDICATED RECEPTACLE, 208V, 30 TELEPHONE OUTLET WITH 3/4" CONDUIT TO TELEPHONE BACKBOARD TEL. OUTLET & DATA OUTLET WITH (2) 3/4" CONDUIT DATA OUTLET WITH 3/4" CONDUIT JUNCTION BOX TO SUIT THE FIELD CONDITIONS MOTOR OUTLET 1. SUBSCRIPT LETTER NEXT TO THE ABOVE SYMBOLS INDICATES DEVICE CONTROLLED 2. DEVICES AND COVER PLATE COLOR AS SELECTED BY ARCHITECT, SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF OUTLET, UNLESS NOTED. COORDINATE REFRIGERATION OUTLET REQUIREMENT WITH HILLS REFRIGERATION PLAN. 3. RECEPTACLES IN BATHROOM, LAUNDRY ROOM, AND KITCHEN SINK AND EXTERIOR LOCATIONS SHALL BE GROUND FAULT TYPE (GFI) EMERGENCY CIRCUIT. LOCK ON DEVICE FOR BREAKER SERVING CIRCUIT BREAKER SWITCH AND FUSES 0-1 DISCONNECT SWITCH ( COMBINATION MAGNETIC STARTER & FUSED DISCONNECT O MANUAL MOTOR STARTER 3-P, W / OVER LOAD PRETECTION MQ WATT/HOUR METER SOCKET • SMOKE DETECTOR El TRANSFORMER m PAD MOUNTED TRANSFORMER WI u SWITCHBOARD CURRENT TRANSFORMER - PANELBOARD TELEPHONE CABINET WITH BACKBOARD NOTES: 1. BREAKERS, SWITCHES, FUSES, METER SOCKETS, AND CURRENT CARRYING DEVICES SHALL BE DESIGNED TO WITHSTAND MAXIMUM AVAILABLE FAULT CURRENT (AFC) ESTABLISHED BY SERVING UTILITY 2. SWITCHBOARDS AND PANELBOARDS BUSSING SHALL BE BRACED TO WITH- STAND MAXIMUM AVAILABLE FAULT rA-1,3,5 > CONDUIT HOME RUN TO SOURCE INDICATING PANEL "A" CIRCUITS # I, 3 & 5 CONDUIT RUN CONCEALED IN CEILING SPACE OR IN WALL CONDUIT RUN BELOW FLOORS OR IN GRADE HASH MARKS INDICATE QUANTITY OF CONDUCTORS. NO HASH MARK INDICATES #10 2 #12 AWG. U.O.N. (#10 INDICATES # 10 AWG. CONDUCTORS) SIZE OF CONDUIT SHALL BE BASED ON TABLE 1. CHAPTER 9 OF N.E.C. AMD TABLE 3A AND 3B SHALL DETERMINE THE CONDUIT SIZES. MINIMUM CONDUIT SIZE SHALL BE 1/7'. TELEPHONE CABLE IN 3/4" CONDUIT TELEVISION ANTENNA CABLE IN 3/4" CONDUIT - S - CONDUIT RUN FOR SPEAKER SYSTEM. 3/4" C. U.O.N. - F- CONDUIT RUN FOR FIRE ALARM SYSTEM. 3/4" C. U.O.N. D. NOTES: 1. TELEPHONE AND TELEVISION CABLES MAY BE PREWIRED BY LOCAL TEL/COMM/CABLE T.V. COMPANY. 2. ALL CONDUIT SHALL BE RIGID STEEL OR EMT. FLEXIBLE CONDUIT SHALL BE LIMITED TO 77' FOR FINAL CONNECTION TO LIGHTING FIXTURES OR MOTORS, INCLUDE GROUNDING CONDUCTOR. P.V.C. CONDUIT SHALL BE USED ONLY FOR UNDERGROUND. SHEET INDEX SHEET # SHEET NAME E-100 GENERAL NOTES, SINGLE LINE DIAGRAM E-200 SITE ELECTRICAL PLAN E-300 POWER PLAN E-301 KITCHEN EQUIPMENT SCHEDULE E-400 LIGHTING PLAN E-500 ELECTRICAL ROOF PLAN E-600 PANEL SCHEDULE E-700 ELECTRICAL DETAILS E800 INTERIOR LIGHTING COMPLIANCE LEGEND FIXTURE TYPE LAMPS TYPE INPUT WATTAGE VOLTAGE BALLAST DESCRIPTION FINISH MOUNTING LOCATION REMARKS A / AE NAE 1 LED 42 UNI LED DRIVER 2' X 4' RECESSED MOUNTED TROFFER LED LIGHT COMMERCIAL LIGHTING INDUSTIES: FOR A TYPE: CLI-NAJOLA FOR AE TYPE CLI-NAJOLAE RECESSED INDOOR 0-10V DIIMMING/ 90 MINUTES BATTERY BACKUP B/BE LED 25 UNI LED DRIVER 2' X 2' RECESSED MOUNTED TROFFER LED LIGHT COMMERCIAL LIGHTING INDUSTIES: FOR B TYPE: CLI-NAJOLB FOR BE TYPE :NAJOLBE RECESSED INDOOR 0-10V DIIMMING/ 90 MINUTES BATTERY BACK UP ® q) x 1 LED 4.5 120/277 UNIVERSAL MOUNTED EXIT SIGN COMMERCIAL LIGHTING INDUSTRIES: CLI-NAJOLEXIT ANODIZED ALUMINUM WALL INDOOR 90 MINUTES BATTERY BACK UP -- - -- --- -- (Mi (E) 30 0A 01 Z. 0; (E) PANEL A L___J (E) MAIN DISTRIBUTION BOARD "MS" (E) 1200A, 120/208V, 30, 4W BUS 42KAIC , WITHIN) 4 #3/0 & 1 #3 GND N (NI PANEL 'B' 100A 100A 3P 0 z IN) PANEL ' Al' 0 0 4t IN) PANEL 'C' I (E) �� 32p00A / SINGLE LINE NOTES: 1. ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO ORDERING NEW EQUIPMENT/DEVICES. 2. ELECTRICAL CONTRACTOR / OWNER TO REQUEST A NEW SERVICE FROM THE LOCAL ELECTRICAL SERVICE PROVIDER. 3. ELECTRICAL CONTRACTOR / OWNER TO REQUEST A NEW AIC (AMPERE INTERRUPTING CAPACITY) PROTECTION FROM THE LOCAL ELECTRIC UTILITY COMPANY. 4. ALL CONDUCTOR SIZES FOR THIS PROJECT SHALL BE THHN/THWN COPPER AWG OR KCMIL PER 2014 NEC TABLE 310.15 (B) (16). 5. TRANSFORMER SHALL HAVE A DISCONNECTING MEANS LOCATED IN REMOTE LOCATION AND FIELD MARKED ON THE TRANSFORMER AS PER 2014 NEC ART. 450.14. LEGENDS: NEW WORK --- EXISTING TO REMAIN, U.O.N. r' / , DEMOLITION (E): EXISTING. FIELD TO VERIFY. (EF): EXISTING FEEDER. FIELD TO VERIFY. (N): NEW (R): EXISTING TO BE RELOCATED. FILE COPYf GG FarmIt No, ' L. )C(.li 'vie* appicva' IS SubRCt tC effort an0 '•sS.cr•, Acpe.,ve! of constructer eocurflelis aloes .1E e.pial n Ot any aeoolea GIOe ov -'aorovscF;ecisnvaae aWr+d Iv:SsJN REVISIONS Tak.wtla Bui c i s,(j,• ke��sibns ea u will r NOTE: � �� E• a new Wan suarnittal anc 7rlav slcude a 3 li ona plan rev*w ry- iO°NF I I` • 1352•C'Z7'Mt /L City of Tukwila 6UI'.P1NG cIvIAION� SEPARATE PERMIT RE UIRED FOR: Mechanical ❑ Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION Ilio. EIs ::.v crry OF TLJKWiL;;. SEP 0 5 2019 ?ERMIT CENTER CORRkCTION LTR# SINGLE LINE DIAGRAM SCALE: 4- 1) NTS 1 Jollibee CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP PLUMPGIFIOUP c."Ire,:rusF a division 914 ANAHEIM. P (114) 4# A Fxo NeER PJC, ul ?Lmo En9ineedng, Inc. E. KATELLA AVENUE CALIFORNIA 92305 385.1935 F(114)995-1534 awisioneourscm STAMP ..Jff �`af ixR D A. p WAS4, A , co N O a‘fss�NALTEE*3 7 ,p 34218 cz, �', EXP. 03/19/20 PROJECT NAME/ADDRESS: Jdlibss TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 1 020719 BID ISSUE 2 022519 BID ISSUE Qi 053119 CORPORATE REVISIONS 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL s% 071119 MECHANICAL CORRECTIONS Q 071919 ELECTRICAL CORRECTIONS A 072519 BUILDING CORRECTIONS 5 090519 2ND RESUBMITTAL JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT GENERAL SINGLE LINE NOTES DIAGRAM & 0 SHEET NO E-100 SEE ENLARGED POWER & LIGHTING PLAN 1 L 77777- / / /7/ ;r/ //-7'/77`/T/- ` I F / / / //////// ///// / / // / / /////// (/r�% ////// ///// / /// //////////r-N.aA'///////�/// I/ / / //////// //L�€ r:✓/777 // ///// / / / A / / //////// // ////// ///// / / / // 2 //////// //////// /////// / // / %1 ///////, ///////i,%///, ///11zi -- == L� r L- I - - - - - P L 1 4 I I I! I I 1 • \ • • • \ • \ • • • • • • • • • • • • \ \ \ • \ \ \ • • \ \• \ • • • • • • • \ •\ • • \• • \ • • • • \ \ \ • \ • • • • • • • • • \ \ \ \ \ \ \ • \ • • • \ \ •• • \ • • \ \ • • • • • • • • \ • • \ • \ • • • \ • • \ • \ \ • \ • • • \ • GENERAL NOTES 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITION AT THE JOB SITE BEFORE COMMENCING ANY PHASE OF THE WORK. ADJUSTMENT FOR FIT AND COORDINATION SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 2. ELECTRICAL CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, CIVIL MECHANICAL & STRUCTURAL DRAWINGS AND SPECIFICATION FOR ANY ADDITIONAL REQUIREMENTS. 3. CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES. 4. ALL CONDUIT SHALL BE AS STRAIGHT AS POSSIBLE AND PARALLEL OR PENPENDICULAR TO THE BUILDING LINES. 5. PROVIDE MULTI -CONDUCTOR HOMERUNS AS SHOWN AND USE #10 AWG NEUTRAL. PROVIDE GREEN GROUND WIRE IN ALL RACEWAYS. 6. SEAL ALL WALL ROOF AND FLOOR PENETRATION WITH UL LISTED FIRE SEALANT. 7. ALL CONDUIT SHALL BE ROUTED CONCEALED WITHIN WALLS AND OR ABOVE CEILINGS. 8. REFER TO ALL ARCHITECTURAL ELEVATIONS FOR EXACT MOUNTING HEIGHTS OF ALL DEVICES. 9. REFER TO ALL MECHANICAL DRAWINGS FOR ALL HVAC EQUIPMENT LOCATED ON ROOF. of Tukwila BUILDING DNI.¢Inu 7 ;1'r3 NORTH ELECTRICAL SITE PLAN SCALE: 1/16"=11-0" 1 CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED 10 THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4 Pr,HICeG.0 E .6 tii.alNeLP:t1,3 a divisional Plump Engineering. Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92105 P I114)315-1885 Fp141885-1134 kwfuwwfwatom STAMP Ap DW A. A! ,� _-- \\p,R 4G OF WASy/ Ck, — z 9 34218 O �fSS�NALTEENO��F EA'. 03/19/20 PROJECT NAME/ADDRESS: Jdlibss TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT ELECTRICAL SITE PLAN SHEET NO E-200 GENERAL NOTES c)y D-23 SCOPE OF WORK (E) PNL „D” 7 tD+15,17 KEY NOTES r Al-1B - tON ROOF) II L6-201R LB-24R 8x 36 r a 6 30/32 C m, -30/32 • t?.v 0.9 i"r ...fin. L...- / • 111 1- ■ 1 Itnr,MA.* t»..Wlll VfAVM•.811)l.!!t.]lM l\}.)N i. yul NTa Fin0 18xE J ::Mir watrWRi wMerrdW'ion or ..1.71VArvrr•ttvnr•unn'. J 04 .• N ?elr'ri•1r)isi''i•Lr+`•••:/G'•'iOi:i:oi:i°i :•nrne" b:d0.16s•h ri..!rirti .;Y't6..Q•n'biY a'4.:}h n'4n n4 1 8)(72 ALL 120VOLTS, 20 AMP RECEPTACLES LOCATED UNDER COUNTERS WITHIN SERVICE AREA AND KITCHEN AREA TO BE SERVED FROM GFCI TYPE CIRCUIT BREAKERS PER 2017 NEC 210.8 (B) (2). 1. REFER TO ARCHITECTURAL PLANS FOR ALL DEVICE FINISHES. 2. CONTRACTOR SHALL REFER TO KITCHEN EQUIPMENT DRAWINGS FOR ALL EQUIPMENT AND CONTROLS (QUANTITIES AND LOCATIONS). AND REQUIRED CONTROL WIRING. 3. ALL RECEPTACLES AND SWITCHES PLATES SHALL BE IN COLOR SPECIFIED BY ARCHITECT. 4. E.C. SHALL REFER TO KITCHEN DWGIS) FOR ELEVATION EXACT HEIGHTS FOR ALL RECEPTACLES AND SWITCHES. 5. ALL WIRING, INCLUDING LOW VOLTAGE. SHALL BE IN CONDUITS. 6. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOMERUNS. PROVIDE AND INSTALLED CONDUITS, CONDUCTORS BOXES. MISC. FITTINGS. ETC. FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION AND N.E.C. 2017. 7. ALL 125V, SINGLE PHASE, 20A RECEPTACLE(S) INSTALLED IN THE KITCHEN SHALL HAVE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL, 2017 NEC ART. 210.8(B). 8. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET 24" MINIMUM. 9. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL. 10. ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C. RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR. • DENOTES CIRCUIT DESIGNATION MINIMUM BRANCH CIRCUIT WIRING SHALL BE MINIMUM OF # 12 AWG (HOT), # 12 NEUTRAL PLUS # 12 GROUND IN 3/4" CONDUIT (MIN.) TWO OR MORE CIRCUITS MAYBE INSTALLED IN ONE CONDUIT FOR BRANCH WIRING AND HOMERUN TO PANEL PER PROVISION OF 2014 N.E.C. PROVIDE #10 AWG WHEN TWO OR THREE CIRCUITS SHARE A COMMON NEUTRAL. ❑2 PROVIDE 100A, 120/208V, 3 PHASE, 4 WIRE, PANEL "Al". g DEMOLISHED THE 200A, 120/208V. 3 PHASE, 4 WIRE, 42 SPACES, PANEL'S" AND REPLACE WITH NEW 400A, 120/208V, 3 PHASE, 4 WIRE. 42 SPACES, PANEL "B". ® DEMOLISHED THE 100A. 120/208V, 3 PHASE, 4 WIRE. 24 SPACES, PANEL "C" AND REPLACE WITH NEW 100A, 120/208V, 3 PHASE. 4 WIRE 42 SPACES, PANE. "C". ▪ KEEP 3 FEET CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT PER 2017 N.E.C. CODE REQUIREMENTS. © WALK-IN COOLER AND WALK-IN FREEZER MUST COMPLY INSTALLATION RACEWAY SYSTEM PENETRATIONS MUST BE SEALED AS PER 2014 NEC ART. 300.7. O7 E.C. TO PROVIDE 1" CONDUIT WITH PULL CORD STUB AT ACCESSIBLE CEILING SPACE RUN THRU EXISTING MAIN TELEPHONE BACKBOARD. EC TO COORDINATE WITH TELEPHONE/DATA INSTALLER BEFORE ROUGH -IN. n PROVIDE 208V, 10. 2P, 3W, 20 AMP RECEPTACLE, NEMA 6-20R WITH 3 # I0 & 1 # 10 GND. PROTECTED BY GFC CIRCUIT BREAKER AS PER 2017 NEC ART. 210.8 (B). • PROVIDE 125/250V, 10, 4P, 4W. 20 AMP RECEPTACLE, NEMA L14-20R WITH 4 #10 & 1 #10 GND. PROTECTED BY GFC CIRCUIT BREAKER AS PER 2017 NEC ART. 210.8 (B). 10 PROVIDE 250V, 30, 4P. 4W, 50 AMP RECEPTACLE. NEMA 15-50R WITH 4 #8 & 1 #10 GND. PROTECTED BY GFC CIRCUIT BREAKER AS PER 2014 NEC ART. 210.8 le). 12 PROVIDE 250V. 10, 2P, 3W, 20 AMP RECEPTACLE, NEMA L6-20R WITH 3 # 10 & I #10 GND. PROTECTED BY GFC CIRCUIT BREAKER AS PER 2014 NEC ART. 210.8 CB). El HEAT TRACE GROUND FAULT PROTECTION OF EQUIPMENT SHALL BE PROVIDED FOR HEAT TRACING AND HEATING PANELS. _Ir...T ---1 T r $ii•Di.O •SSOA'9'' i'.••w'O":1?4`.:'Ao..v:,:wd:+.' 1 BY6D E.1 CRY O + SEP 17 26SE Clty of Tukwila NORTH 1 POWER PLAN SCALE: 1/4"=1-0" 1 Jdlibss CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4 OP PLUMPGROUPI AVLxnrc[VR a *loon of Pbrtp Engineering, Inc. 911 E. XATELLA AVENUE ANAHEIM. CALIFORNIA 12105 P 17111355.1535 F(711) 3154834 N..aM:T19Aleam STAMP NC/ Pp FfvsoNaLTiE���� p,R D. A. p e- WASP <<'4 z y 34218 EXP. 03/19/20 PROJECT NAME/ADDRESS: Jdlib.s TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT POWER PLAN SHEET NO E-300 W 1- REMARKS GAS PLUMBING WASTE N AOTER COLD WATER ELECTRICAL CONNECTION LOAD SIZE RIH MBTU TYPE SIZE RIH SIZE RIH I SIZE RIII TYPE AMPS KW HP i VOLTS a JOLLIBEE ca u z a MODEL NUMBER MANUFACTURER zz a 8 DESCRIPTION 12/27/2018 2 1- a 2 REMARKS PLUMBING ELECTRICAL JOLLI BEE 1/15/2019 GAS SIZE RIH MBTU WASTE TYPE SIZE HOT COLD WATER WATER RIH SIZE RIH SIZE CONNECTION LOAD RIH I TYPE AMPS KW I HP 1 VOLTS INSTALLED BY PURCHASED BY MODEL NUMBER MANUFACTURER 1- z CI DESCRIPTION u 2 58 FS 59 60 61 61.1 SEE CAPTIVAIRE 62 62.1 FOR FRENCH FRIES FRYER FOR GRIDDLE 62.2 '63 FOR HALO HALO r64 65 66 67 68 r 67 NEMA 5-15P NEMA 5-14 NOT USED NOT USED D 120 GC GC O 0 GC GC GC GC GC 0 GC 0 GC 0 MILLWORK CUSTOM 5/S CUSTOM S/5 CUSTOM S/5 BY GC CAPTIVEAIRE ALLSTRONG ALLSTRONG ALLSTRONG 1 (E) WALK-IN FREEZER 1 2 2 1 CREW TABLE CREW CHAIR FIRE SUPPRESSION CABINET FIRE SUPPRESSION PULL BOX 1 12" S/S WORK TABLE 1 12"S/SWORKTABLE 1 24"X30" WORK TABLE 2 TRASH BIN 58 59 60 61 61.1 62 62.1 62.2 63 C 1.5 C 5.4 C 13 1.55 1/2 120 1 115 1 120 GC 0 GC 0 GC 0 EV9437-42 T-49-HC RCS1OTS EVERPURE TRUE AMANA 1 1 NOTE USED MAIN WATER FILTER 2 DOOR CHILLER CREW MICROWAVE NOTE USED NOTE USED 64 65 66 67 68 69 JOLLIBEE MISCELLANEOUS 70 r 71 73 GC TO PROVIDE MOUNTING BRACKET AND DATA OUTLET GC TO PROVIDE MOUNTING BRACKET AND DATA OUTLET C C 84AFF C 80 SEE ENLARGED PIAN 81 SEE ENLARGED PLAN 55 1 115 1 115 1 115 GC 0 GC 0 GC 0 GC GC GC 0 48" TD 2220 21 MAXIMA MILLWORK SAMSUNG VIEWSON IC ECOLAB BY GC 5 2 2 MENU BOARD ORDER MONITOR FLYTRAP JOLLIBEE OFFICE ACCESSORIES 1 1MANAGER'S DESK 1 MANAGER'S CHAIR 741 GC TO MODIFY PER PLAN 2 3 NEMA5.15P 4 4.1 4.2 5 r6 r6.1 r 6.2 7 8 8.1 8.2 8.3 8.4 NEMA 5-15P NEMA 5-15-P STEAM TABLE INSERT STEAM TABLE INSERT STEAM TABLE INSERT STEAM TABLE INSERT 8.5 STEAM TABLE INSERT 9 71 10 7%11 12 9113 81 82 SEE ENLARGED PLAN =Y12 SEE ENLARGED PLAN C 1 115 1 115 GC GC GC 0 522E4050B .SAMSUNG 1 1 CCTV MONITOR COMPUTER MONITOR 82 83 SEE ENLARGED PLAN, 32 CHANNEL C 1 115 GC GC CSMA 1220 1BL 1 AMPUFIER 84 84.1 SEE ENLARGED PLAN C 1 115 GC GC BDP-5590 SONY 1 DVDPLAYER 841 85 SEE ENLARGED PLAN 1 115 GC 0 1 COMPUTER/KEYBOARD 85 86 87 88 89 SEE ENLARGED PLAN SEE ENLARGED PLAN SEE ENLARGED PLAN SEE ENLARGED PLAN C 1 115 1 115 GC 0 GC 0 GC GC GC GC MFC-9130CW MILLWORK MILLWORK TRIPP LITE BROTHER BY GC BY GC 1 SERVER CAGE 1 PRINTER/SCANNER/FAX 1 FILE CABINET 1 WALL SHELVINGS 86 87 88 90 ON 6" CONC. CURB GC 0 1 VAULT 90 LEGENDS FS - INDIRECT WASTE TO FLOOR SINK D- DIRECT WASTE SC - SELF CONTAINED ACH - ABOVE COUNTER HEIGHT D- DIRECT CONNECTION ACH - ABOVE C-CONVENIENCEOUTLET COUNTER HEIGHT FS - FLOOR STUB -OUT DC - DROPPED CORD 0-OWNER GC- GENERAL CONTRACTOR EC- ELECTRICAL CONTRACTOR ES - EQUIPMENT SUPPLIER SC- SIGN CONTRACTOR KEC-KITCHEN EQUIPMENT CONTRACTOR KITCHEN EQUIPMENT SCHEDULE SCALE: NTS 1 14 14.1 15 15.1 16 NEMA L14-20P NOT USED NOT USED NEMA 5-15P NEMA 5-15P 16.1 W/ FILTERED COW WATER 16.2 ON ROOF 16.3 BELOW COUNTER 21 21.1 22 NEMA 15-50P W/ CW FILTERED WATER 22.1 23 24 W/ FILTERED COLD WATER 25 NOT USED 25 NEMA5-15P 25.1 27 NOT USED 28 NEMA5-15P 28.1 NEMA 5-15P 29 NEMA 5-15P 29.1 29.2 NEMA6-20P 30 NEMA5-1SP 30.1 31 31.1 STEAM TABLE INSERT STEAM TABLE INSERT STEAM TABLE INSERT NEMA 6-20P STEAM TABLE INSERT 31.6 31.7 NEMA 14-20P 32 NEMA 5-15P 33 34 35 NEMA 5-15P 36 36.1 38.1 NEMA-5-15P 39 39.1 39.2 40 41 42 42.1 42.2 42.3 42.4 43 ON ROOF PROVIDE DATA OUTLET 41" AFF 18x24x12TUB NEMA 5-15 44 183dSx 12 TUB 44.1 45 PREP SINK 45.1 HALOHALO STATION 45.2 CREW STATION 46 W/SPLASH GUARD 46.1 46.2 ACCESSORY TO HAND SINK 47 47.1 48 49 49.1 50 51 52 52.1 52.2 SEE PLUMB. DWG 53 SEEPLUMB.DWG 54 SEE MECH. DWG 55 SEE MECH. DWG 56 57 3/410ACH 112 SC FS FS SC D FS FS 3/4 FS 3/4 FS 3/4 FS 3/4 3/4 90 FS 11/4 3/45.3AFF 80 FS 1 3/4 7ACH 50 3/4 7AFF 3/4 3/4 18" SC SC SC FS 1/2 FS 1/2 FS 100 80 SC 199 FS FS FS 1 F5 10AFF 1/2 3/8 3/8 3/8 C C 4.9 C 3.8 j 0.225 C 4 D 8.7 1.8 D 9.3 1.12 C 17.5 ! 4.2 C 3 C 131 C 9.3 0.2 0.34 0.16 1.57 3/8 48ACH C 20.1 6.8 3/4 &5ACH 3/8 1/4 1/4 5.3AFF 3/8 7 ACH 3/8 24AFF 25AFF 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 15 6 C 42 1 8 C 4 c . 15 L75 C 5 C 4.9 j C C 15.4 14.7 3.2 1.8 D 6.9 F 0.8 D 10 C 22 ; 4.5 1.2 C 1L2 ! 1.34 C 10 1.2 C 9i C 5 C 3 0.1 C 4.2 I 0.5 C 4.6 0 27.7 I D 2.6 C 20 C 12 ! 15 C C 14.7 I 3 D 1 1 1 120 115 115 115 208 GC 0 0 GC 0 GC 0 CUSTOM S-LINE II TSSU-27-12M-8•ADA CUSTOM S/5 GC 0 CUSTOM S/5 GC 0 HC-8E GC 0 25F GC 0 CUSTOM S/5 GC 0 HS-16151N GC 0 CUSTOM 5/S GC 0 CUSTOM S/S GC 0 CUSTOM S/5 GC 0 MOD-2000 GC GC B-0208 GC O 3041 GC 0 CUSTOM S/S 1 208 GC 0 GRAHL-24D 1 1 1 120/208 GC 0 115 120 1 115 1 115 1 115 3 120 GRSOH-60D GC 0 D15-3 GC 0 VP17-2-BLK GC 0 C2410C GC 0 C2410C IDC215 CIM053OR RCA-1001 GC 0 IHPA-2.24 GC 0 CUSTOM 5/S 208 GC 0 GC 0 120 GC 0 120 GC 0 E62083E150 CUSTOM 5/5 FGP55 GPCRB 120 GC 0 GGF201A2400-TI GC 0 CUSTOM 5/5 1 120 GC 0 300NDNL 0.3 1 115 GC 0 TUC-27F-HC 0.2 1 115 GC 0 TSSU-27-12M-B-ADA GC 0 1 208 GC O 120 GC 0 GC 0 GC 0 1 208 GC O 1 1 1 0.3 1 1/5 1 1 1 1 120 GC 0 GC 0 208 GC 0 GC GC CUSTOM S/S RC2252 VCT-25 CUSTOM S/5 CUSTOM S/S HSW-6D MOD-100D CUSTOM 5/5 FR-4 B-0580 GC 0 CUSTOM 5/S 120 GC 0 GRSDS-41 120 120 115 115 120 208 1 208 120 GC 0 GC 0 GC 0 GC 0 GC 0 GC 0 PFG-691 FPH155-2CSE TUC-27F-HC T-23-HC CUSTOM 5/5 2901 - 6" GC 0 CUSTOM 5/S GC 0 CUSTOM S/5 GC 0 WRS-108885 GC 0 CUSTOM S/S GC 0 82060 GC 0 GC 0 GC 0 GC 0 GC 0 GC GC GC GC GC 1 110 GC 120 6100A ICE1806HR B100P5 VCR-5051B 0 O 5361824-2D24-C GC 8-0231 GC B-0133-ADF12 B O CUSTOM S/S GC 40GAL GC 0 GC 0 CUSTOM 5/5 S1B1818.1D18-C GC GC GC 0 CUSTOM S/5 GC 0 GC 0 GC 0 GC 0 GC 0 GC 0 CUSTOM 5/5 CUSTOM S/S HAS CUSTOM GUAG1100 CYCLONE GC GC SEE MECH. DWG. GC GC SEE MECH. DWG. 1 208 GC 0 HHC990 120 BY GC PIONEER POS TRUE ALLSTRONG ALLSTRONG HATSUYUKI GLOBAL INC. ALLSTRONG ALLSTRONG ALLSTRONG ALLSTRONG ALLSTRONG WELLS T&SBRASS FISHER ALLSTRONG HATCO HATCO CRATHCO BUN N-O-MATIC SAN JAMAR SAN JAMAR CORNEUUS ICE-O-MATIC ICE-O-MATIC IMPERIAL ALLSTRONG ACCUTEMP ALLSTRONG FRYMASTER FRYMASTER ACCUTEMP ALLSTRONG THERMODYNE TRUE TRUE ALLSTRONG AMANA ROUNDUP AUSTRONG AUSTRONG WELLS WELLS ALLSTRONG HATCO T& $ BRASS ALLSTRONG HATCO HENNYPENNY FRYMASTER TRUE TRUE ALLSTRONG FISHER ALLSTRONG AU -STRONG SMARTCHEF AUSTRONG SERVER PRODUCT NEMCO ICE-O-MATIC ICE-O-MATIC ICE-O-MATIC RTI RTI ALLSTRONG T & 5 BRASS T & S BRASS ALLSTRONG CHEMX WORKS ALLSTRONG ALLSTRONG T&SBRASS ALLSTRONG ALLSTRONG ALLSTRONG ALLSTRONG CUSTOM ACKLANDS GRANGER METRO AO SMITH CAPTIVEAIRE CAPTIVEAIRE HENNY PENNY JOLUBEE SERVING AREA EQUIPMENT 1 EXISTING FRONT COUNTER 2 EXISTI NG POS TERMINAL 1 COLD TABLE 1 ICE SHAVER TABLE 1 ICE BIN 1 ICE SHAVER 1 CHEST TYPE FREEZER 1 BACK COUNTER 1 DROP IN HAND SINK 1 S/S ICE BIN 1 ASSEMBLY COUNTER 1 STEAM TABLE 1 1 1 1 1 FOOD WARMER FAUCET FILLER DIPPER WELL OVERHEAD SHELF HEAT LAMP HORZONTAL FOOD WARMER NOTE USED NOTE USED 1 2 3 4 4.1 4.2 5 6 6.1 6.2 7 8 8.1 8.2 8.3 8.4 8.5 9 10 11 2 JUICE DISPENSER 12 1 COFFEE DISPENSER 13 2 (E) CUP DISPENSER 14 1 (N) CUP DISPENSER 14.1 1 (E) BEVERAGE COUNTER 15 1 (E)COUNTERTOPTRASHRECEPTACI 15.1 2 (E) SODA DISPENSER 16 2 (E) ICE MAKER 16.1 2 (E)REMOTE CONDENSER 16.2 2 (E)SODAMACHINECOMPRESSOR 16.3 JOLLIBEE KITCHEN AREA EQUIPMENT 1 2 BURNER HOT PLATE 1 1 1 1 1 s/s BURNER STAND RICE STEAMER EQUIPMENT STAND W/ CASTERS RETHERMALIZER PASTA COOKER NOTE USED 1 GRIDDLE 1 EQUIPMENT STAND W/ CASTERS NOTE USED 1 BURGER HOLDING CABINET 1 FREEZER BASE 2 SANDWICH TABLE 2 OVERHEAD SHELF 2 MICROWAVE 1 BUN TOASTER 1 S/5 BUN TOASTER STAND 1 STEAM TABLE 1 1 1 1 1 1 OVERHEAD SHELF 1 HORZONTAL FOOD WARMER FOOD WARMER FOOD WARMER SMALL COLD PAN ELECTRIC WARMERS POT FILLER 4 CHICKEN JOY FRYER 2 FRENCH FRIES FRYER 1 FREEZER BASE 1 REACH IN REFRIGERATOR 1 BREADING TABLE 2 3 3 2 1 2 1 1 1 1 2 1 1 1 1 2 1 V 1 1 2 1 1 2 3 2 V V 1 2 2 3 1 1 1 1 1 1 1 1 1 FAUCET BREADING PAN ICE BIN RICE WARMER MOBILE RICE WARMER TABLE FOOD WARMER BURGER GRAVY DISPENSER ICE MAKER ICE BIN REMOTE CONDENSER EXISTING OIL POLY TANK EXISTING OIL POLY TANK FILL BOX 3-COMPARTMENT SINK FAUCET PRE -RINSE FAUCET w/ FAUCET S/S WALLSHELF 0-CARBONATOR 5/5 SPLASH GUARD PREP SINK FAUCET 60" X 15" 5/5 WALL SHELVES 72" X 15" S/5 WALL SHELF AT 36" X 15" 5/5 WALL SHELF WALL MOUNT HAND SINK PAPER TOWEL& SOAP DISPENSER EYE WASH 5/S W IRE SHELVING (E) WET WIRE SHELVINGS (E) BAG -IN -A -BOX (E) CO2 TANK (E) CO2 FILL BOX (E) LOCKER (E) BACK DOOR AIR CURTAIN (E) BACK OF HOUSE 5/S MOP SINK (E) CHEMICAL SHELF W/ MOP RACK (E) MOP SINK FAUCET (E) GAS WATER HEATER EXHAUST H000 TYPE I EXHAUST HOOD TYPE I CHICKEN HOLDING CABINET (E) WALK-IN COOLER 21 21.1 22 22.1 23 24 25 26 26.1 27 28 28.1 29 29.1 29.2 3C 30.1 31 31,1 31.2 31.3 31.4 31.5 31.E 31.7 32 33 34 35 36 36.1 36.2 36.3 37 37.1 38 38.1 39 39.1 39.2 4C 41 42 47.1 42.7 42.3 42.4 43 44 44.1 47 47.1 48\ fir) a CI RiJIL 55 57 tug of CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED 10 THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4 OP PLUPPGROUP 914 E. KATELLA AVENUE STAMP PROJECT NAME/ADDRESS: imam TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL JOB NUMBER r ?Snarl BY CHECKED BY PEI PEI SHEET CONTENT IEWEte OW N 'sc. EQUIPMENT -IEDULE Enzaq SHEET NO of Tukwila NG DIV ION .. 30 1 i..;:4, .4 ... 40') GENERAL NOTES 1. FIXTURES SHALL BE COMPLETELY FACTORY ASSEMBLED, WIRED AND EQUIPPED WITH ALL NECESSARY SOCKETS, LED DRIVER, SUPPORTING HARDWARE AND ACCESSORIES. PLEASE REFER TO ARCHITECTURAL DWG(S) FOR INDIVIDUAL FIXTURE DESCRIPTION. 2. PLANS ARE PREPARED WITH REQUIRED BRANCH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS, BOXES, MISC. FITTINGS, ECT, FOR A COMPLETE OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION AND N.E.C. (2017). 3. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURES LOCATION AND DETAILS. SUBSCRIPTS IN LIGHTING PLAN DENOTES SWITCH. EXAMPLE: 2A, 2 DENOTES CIRCUIT NUMBER AND A DENOTES SWITCH THAT CONTROLS CORRESPONDING LIGHTS, 4. HALF -SOLID HATCHED FIXTUREIS) INDICATES EMERGENCY FIXTURE(S). 5. VERIFY ALL LIGHTING FIXTURES AND SWITCHES MOUNTING HEIGHTS AND LOCATIONS IN THE FIELD. 6. VERIFY EXACT LOCATION AND MOUNTING HEIGHT OF LIGHT FIXTURES AND EXIT SIGNS WITH ARCHITECTURAL PLANS AND TENANT, PRIOR TO ROUGH -IN. COORDINATE EXACT LIGHT FIXTURE LOCATIONS WITH CABINETRY, MILLWORK, TABLES, REFRIGERATION PIPING, DUCTWORK AND OTHER TRADES TO AVOID CONFLICTS. CONTRACTOR SHALL BE RESOLVED PRIOR TO INSTALLATION OF LIGHT FIXTURES. 7. PROVIDE A MINIMUM OF 6'-0" SLACK CONDUCTORS AT EACH JUNCTION BOX CONNECTING POWER TO LIGHT FIXTURES. 8. THROUGH WIRING OF RECESSED LIGHT FIXTURES, IN SUSPENDED CEILINGS, IS NOT PERMITTED. CONNECT EACH LIGHT FIXTURE BY A WHIP TO JUNCTION BOX. 9 PROVIDE CABLE WHIPS OFSUFFICIENT LENGTHS TO ALLOW FOR RELOCATING EACH LIGHT FIXTURE WITHIN A 5-FOOT RADIUS OF RS INSTALLED LOCATION, BUT NOT EXCEEDING 6 FEET IN UNSUPPORTED LENGTHS. 10. ALL LIGHTING FIXTURES SHALL BE SUPPORTED PER 2017 NEC ART. 410.16 (C). KEY NOTES El REPLACE EXISTING SWITCH WITH A NEW DIMMER. lj NEW VACANCY SENSOR. E❑ PROVIDE ULTRASONIC OCCUPANT SENSOR WITH 500 SQUARE FEET CONTROL AREA. OR APPROVED EQUAL. O CONNECT NEW EXIT SIGN TO THE NEAREST LIGHTING BRANCH CIRCUIT. r, p is -=-'I 1 7-77..7 jam,/ --- ////////////TTT // ////4//Azz.zzz/ //A /- f ///I '///////////i:. ////////// 1 '/ i// ////////////A // U ////////////SSS//////////// ///////////7 ///////////// ////////////// //j///////////// /////////////// ///r I //////////// //I ///////////// ///1//////////// • •///////////////2 ///r///7 ////z�/./ ////////%/////// // V-i/////////////////// 1.../.../...I.LL.ZZ_/////////1... SCOPE OF WORK 7-7-7-7-7-777"77 7777TTJ,,.j 777-7j7r7/ / // / 77 ///4 // /// // 1//// 747/ /7// //Y//, /// 7/// //i /i / 1 77/x7-ri/ /7 ///% /i/i/ / //// 7 7%7%7777 rf l /////// / / 777. ' //////////// //////////// / // / / ////7///// / // / // //ii/ii/ii//////// 7 ,4)//r / ////// 7 / / /// /' / //// ////// ///7// ////// / /// / /I/ / /0 ////// // / /// f <7. /////////// 7/ /✓//////// /// / /2////// ///// ' /////////.////// .fi/////(r///// // //// ////////// /7%7c :/�///'/// /1A/v;I ;'///////t////////////// ///// / // / //:7///,:✓/////% % /// //,✓ i / /// /// /// // ///// r 1//f11,�//A ,+/ ...<// V/// // // I/ // // // // ////// /7-///f,1.//////Y://///7///////✓////////////// ////// //A r/k'/// M:// ////////////!///////!/// ////// /// ////i/// / /////// ///( )////////'1//////////// //////////} // ///�7////A i/., )'- /// -/r/'/ n////s/// //////////// //////////////, Y/. }/ ///////'///////////////////) T ...I SEP 17 2019 City of Tukwila I QUILOINC. rinnclfA NORTH 1 LIGHTING PLAN SCALE: 1 Jdlibs. CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 1 RAIMPNEUR 0.i<PP!!Iu c.ruJ a OMobn of r'k np EngineSnq. ht. 914 E. KATELLA AVENUE ANAHEIM. CALIFOFNIA 12905 P (T14) 395.1135 9114) 315'1e34 weNP1PWP.P.0.T STAMP N. �0 -4' p,R D A. p4 r. WAgy G� 2� ,P 34218 O Ck- 61 / i i. (,.\a4 L ,,--- EXP. 03/19/2o PROJECT NAME/ADDRESS: Joliibss TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT LIGHTING PLAN SHEET NO E-400 e6529 KEY NOTES: V / 7-71L/ T/-- C/ 7 / /._ . / / / / --7.----7 -------2 / ...... / / --.. / ..-, -.._/ .. r / / / / 7 7 --7 -T --T ...7 i 7 / T — / 7 7- / 7-7-T T 7— 7 / / / / --/ / r ---- --- T---7__ ,, r:..../.:t f- Z -f= - r=:-7 -- ---/—/rt - / / y /- / ,�._./ -- / r / —/ ,, - / /- - IL// / / / / / / / / / ♦ / ♦ / / / / ♦ / / / �' / / / / / / / / / / / / / / 1 ♦ / % /' / / ---- / / y ♦ ♦ ♦ ♦ ♦ ♦ ♦ / / � / / / / / / / / / / / / / / / / / / / / / / / / / / / / / V h �/ /i / / / / / / /-._T._ / / T_. / / / / / / / / / ♦ / ♦ / / / ♦I ,/ / / / / / / / / / / / / / / / / / / 1 / / / ,/ / / / 7> V I f-' j / / / / / / / / / /' / / / / / / / / / / / / / / / / / �// V// /// ////k/ //////,i/4//////A//2/1//////♦// // // / / / / / / / / / // 4 // /// /// / ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / T.../_..../...../..../ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦/// ♦ / ♦ / ♦ / / / ♦ // // r/ /// /// / / / / / / / / / / / / / /-/ / / ♦ / / / / ✓ /n / / / / / / / / / // // // / / / / / / / ♦/ /// /// /// / / / / / / / / / / / / / / /(i /:. / / / / / /W/ / / / / / / / / //; // ✓/ / / / / / / / / / /// I I/ / / / / / / / / / / / / / / / / / / / / / / / / / / / 4 / / / / / / / / / / / // / / / / / / / / / / / / / / / / 1 r/ f / / / / / / / Al♦ - _4 / / / / / / / / / / / ♦ / / / / / / A ♦ / ♦ / / / / / / / / / / / / / / / / / / / / / / / / / / 1/ / / / / / / /E. / V / / / / / / / / / / //� / / / / / I/ / / / / / / / / / // / / / / / / / / / / / / / / / / / ♦'I/ /�//, / / / >, �E)/I/ / /i / / / / / / / )/max% -d / / / / / / / / / / / / / / // / / / / / p/ / / / / / / / / / / / / / / / / / / / / --. ,.,' _ _ f / / / / / / / / / /...---2' / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / r / / ♦ ♦ ♦ ♦ ♦ / Mk / / ♦ j /nm Al_31/33/3 .� '' ♦ ♦ ♦ ♦ . ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦/ ♦ / / ♦ ♦ / ♦ /IT, ♦ / / / / ♦ / / / / / ♦ / / / / / / / / / / / W / / / xi / / ♦ ?I ♦ / / yL / / / / / / / / / / / g 13p5/17/ / / / / / / Y / / / / / / / / / / / / / r/ / ♦ / / / / / / / / / / ♦ / / / Am \ �� / / / / '5/ f / / / / / / / / / ♦ / / / / / / / / / / / / / / / / / / / / / / / / ♦ ♦ ♦ ; ♦ ♦ ♦ ♦ ♦ / / / / / / ♦ ♦ / w XiNY ♦ / / ♦/ G' \ / / ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ / ♦ / / ♦ / ♦ ♦ ♦ ♦I ,/ ,/ / / / ♦ / / / / / / / / { •` 1 ♦ / / / ♦ ♦ ♦ / / / ♦ ♦ / / / / ♦ / / / / / / . __ L.._ Z / / _ / / / /...... / /.l ... /_._...../ /...._/......_/._.. / _/ _/. ../ / (E) X (E) L (E) D-25/27/2 WPZI C-18 _/ -.,! 1 / / / / / / / / / ♦ / / / / / / / / ♦ / / / / / / / / / ♦ / / ♦ ♦ / ♦ ♦ / ♦ / / / / ♦ / / / / ♦ / / , 1 (N) / / ♦ / / ♦ // / / ..✓ / / / / ♦ / / / / / / / / _ N 25fu!"1Y 0 . / / ♦ / - / /... / / / / / ♦ / { / --f ..l .. / .t.: *-i- is D-26/28/30 WP C-18 41 (N) -37/39/41 1 7 m W C-18 e=, 0 / O 0 • HOMERUN TO PANELBOARD CIRCUITS & RECEPTACLES SHOWN ARE TO BE TIED/ CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS DESIGNATED. (TYPICAL FOR ALL HOMERUN CIRCUITS). 2❑ ELECTRICAL CONTRACTOR TO PROVIDE SERVICE DISCONNECTS. 3❑ PROVIDE WEATHERPROOF GFI ROOF MOUNTED SERVICE RECEPTACLES LOCATED WITHIN 25 FEET OF ANY MECHANICAL EQUIPMENT AS PER 2014 NEC ART. 210.63. ® 30AS, 3P, 250V DISCONNECT SWITCH, WITH 30A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 3/4"C, 3 #8 & 1 #10 GND. n PROVIDE COMBINATION WEATHERPROOF MAGNETIC STARTER/DISCONNECT WITH NEMA 00 STARTER AND FUSES PER MANUFACTURER'S NAMEPLATE RATINGS. © 30AS, 3P, 250V DISCONNECT SWITCH, WITH 25A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURERS INSTALLATION RECOMMENDATIONS. PROVIDE3/4"C, 3 #10 & I #10 GND. 7❑ 30AS, 3P, 250V DISCONNECT SWITCH, WITH 20A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 3/4"C, 3 #12 & 1 #10 GND. ® 30AS, 2P, 250V DISCONNECT SWITCH, WITH 20A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 3/4"C, 3 #12 & 1 # 10 GND. 9❑ PROVIDE3/4"C.3#10& 1 #10GND. n ALL WIRING SHALL BE COPPER, #12 AWG MINIMUM, TYPE THNN/THWN AND RATED FOR 600 VOLTS. n 60AS, 3P, 250V DISCONNECT SWITCH, WITH 5DA DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 11/4"C.3 #6 & 1 #10 GND. Y \J. \. tCTt' T.F -.j2 z SEP 17 2019 C8y O1 Tukwile rn 11' 41; nnnc,nu NORTH ELECTRICAL ROOF PLAN SCALE: 1/4"=1'-0" 1 J.flibss CITY (N) -37/39/41 1 7 m W C-18 e=, 0 / O 0 • HOMERUN TO PANELBOARD CIRCUITS & RECEPTACLES SHOWN ARE TO BE TIED/ CONNECTED PER ASSIGN ZONE AREAS WITH CIRCUIT NUMBERS DESIGNATED. (TYPICAL FOR ALL HOMERUN CIRCUITS). 2❑ ELECTRICAL CONTRACTOR TO PROVIDE SERVICE DISCONNECTS. 3❑ PROVIDE WEATHERPROOF GFI ROOF MOUNTED SERVICE RECEPTACLES LOCATED WITHIN 25 FEET OF ANY MECHANICAL EQUIPMENT AS PER 2014 NEC ART. 210.63. ® 30AS, 3P, 250V DISCONNECT SWITCH, WITH 30A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 3/4"C, 3 #8 & 1 #10 GND. n PROVIDE COMBINATION WEATHERPROOF MAGNETIC STARTER/DISCONNECT WITH NEMA 00 STARTER AND FUSES PER MANUFACTURER'S NAMEPLATE RATINGS. © 30AS, 3P, 250V DISCONNECT SWITCH, WITH 25A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURERS INSTALLATION RECOMMENDATIONS. PROVIDE3/4"C, 3 #10 & I #10 GND. 7❑ 30AS, 3P, 250V DISCONNECT SWITCH, WITH 20A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 3/4"C, 3 #12 & 1 #10 GND. ® 30AS, 2P, 250V DISCONNECT SWITCH, WITH 20A DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 3/4"C, 3 #12 & 1 # 10 GND. 9❑ PROVIDE3/4"C.3#10& 1 #10GND. n ALL WIRING SHALL BE COPPER, #12 AWG MINIMUM, TYPE THNN/THWN AND RATED FOR 600 VOLTS. n 60AS, 3P, 250V DISCONNECT SWITCH, WITH 5DA DUAL ELEMENT FUSES PER EQUIPMENT MANUFACTURER'S INSTALLATION RECOMMENDATIONS. PROVIDE 11/4"C.3 #6 & 1 #10 GND. Y \J. \. tCTt' T.F -.j2 z SEP 17 2019 C8y O1 Tukwile rn 11' 41; nnnc,nu NORTH ELECTRICAL ROOF PLAN SCALE: 1/4"=1'-0" 1 J.flibss CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 41 10 P.._.....LtI a Uivsiun al Plw90ERainseag, be. 914 E. NATELLA AVENUE ANAHEIM, CALIFORNIA 92805 9 0141 886-1138 FI3141395•1834 STAMP TT ' p,R El A. p . �- CT p WASH , ..0 re J 0 34218 % 'Pen �� FSS/a.xP.aI OSLO/ PROJECT NAME/ADDRESS: Joflibss TUKWILA, SPACE WESTFIELD 1374 SOUTHCENTER TUKWILA, WA 372 & 368 LEVEL 1 SOUTHCENTER MALL WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT ELECTRICAL ROOF PLAN SHEET NO E-500 (N)PANEL "Al" VOLTS:120/208V PHASE: 3 A.I C. RATING: 10,000 AMP MAIN: 100A C.B. MOUNTING: SURFACE WIRE: 4 BUSSING: 225 AMP LOAD ' A -VA B-VA C-VA BKR CT CT BKR A -VA B-VA C-VA ' LOAD CREWMCROWAVE K 1560 20/1 1 2 20/1 720 R CASHER FLY TRAP C 300 20/1 3 4 30/2 2600 K SOFT SERVE FREEZER FLYTRAP C 300 20/1 5 6 - 2600 K --- AIRCURTAIN K 612 20/1 7 8 20/1 600 K COLD TABLE FOOD WARMER K 1008 20/1 9 10 20/1 1116 K SODA DISPENSER RICE WARMER, GRAN DISPENSER K 1108 20/1 11 12 20/1 1788 K ICE MAKER SPARE 0 20/1 13 14 20/1 1236 K SODA DISPENSER CASHER R 1080 20/1 15 16 20/1 1788 K ICE MAKER CASHER R 720 20/1 17 18 20/1 720 K ICE MAKER COND. CASHER R 720 20/1 19 20 20/1 720 K ICE MAKER COND. CASHER/PRINTER R 360 20/1 21 22 20/1 SPARE RTI RECEPTACLES R 1000 20/1 23 24 20/1 720 K JUICE DISPENSER STORAGE RM RECEPTACLES R 360 20/1 25 26 20/2 500 R KITCHEN AREA EASTSIDE RECEPT CASHER R 720 20/1 27 28 - ' 500 R --- FOOD WARMER K 1498 20/2 29 30 20/1 200 N SD 8 SF DETECTOR -- K' 1498 -- 31 32 20/1 456 K ICE SHAVER EF-2 M 2041 25/3 33 34 20/1 480 K CHEST TYPE FREEZER -- M 2041 - 35 36 20/2 r 1340 K DRIVE THRU FOOD WARMER - M 2041 -- 37 38 - r 1340 K ICE MAKER K 2881 35/2 39 40 20/1 SPARE -- K r 2881 - 41 42 20/1 SPARE ea PHASE TOTALS: 12363 14874 16916 44153 =TOTAL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 102.9 123.9 140.9 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS• 1.25 X 0 = 0 VA C=CONTINUOUS LOADS, OTHER: 1.25 X 600 = 750 VA M=MOTOR LOADS (INCL LGST): 1.00 X 6123 = 6123 VA LARGEST. VA: 0.25 X 0 = 0 VA R=RECEPTACLES, 1ST 10K: 1.00 X 8680 = 6680 VA BALANCE: 0.50 X 0 = 0 VA K=KITCHEN LOADS: OW: 17 0.65 X 30550 = 19858 VA N=NONCONTINUOUS LOADS, OTHER: 1.00 X 200 - 200 VA NOTES: (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 33611 VA = 93.3 AMPERES (N)PANEL "C" VOLTS:120/208V PHASE: 3 A.I.C. RATING: 10,000AMP MAIN: 100A C.B. MOUNTING: SURFACE WIRE: 4 BUSSING: 225 AMP LOAD ' A -VA B-VA C-VA BKR CT CT BKR A -VA B-VA C-VA ' LOAD CHICKEN FRYER K 1200 20/1 1 2 20/1 SPARE CHICKEN FRYER K 1200 20/1 3 4 20/1 1764 K BUN TOASTER CHICKEN FRYER K 1200 20/1 5 6 2011 1800 K HONDING CABINET CHICKEN FRYER K 1200 20/1 7 8 20/2 1602 K MICROWAVE RICE STEAMER K 5041 60/3 9 10 - rr 1602 K --- -- K ' 5041 - 11 92 20/1 648 K 2 DOOR CHILLER -- K F 5041 -- 13 14 20/1 1080 K FRENCH FRIES FRYER RETHERMALIZER K 120 20/1 15 16 20/1 1080 K FRENCH FRIES FRYER SPARE 20/1 17 18 20/1 ' 1080 R ROOF RECEPTACLES SPARE 20/1 19 20 20/3 300 M (E)MJA-1 FROZEN BEVERAGE FREEZER K 1768 25/2 21 22 - 300 M - -- K r 1768 - 23 24 - 300 M - AIR CURTAIN M 612 20/1 25 26 20/1 SPARE SPARE 20/1 27 28 20/1 1200 K LIGHTDOOR)HEATER MICROWAVE K 1602 20/2 29 30 20/2 967 C HEAT LAMP K ' 1602 -- 31 32 - r 967 C •-- PASTA COOKER K 960 20/1 33 34 20/1 480 K GRIDDLE FREEZER BASE K 600 20/1 35 36 20/2 900 K FOOD WARMER COFFEE DISPENSER K 1600 20/1 37 38 - 900 K -- 20/1 39 40 20/2 1560 K HORIZONTAL FOOD V17ARMER 20/1 41 42 - 1560 K - PHASE TOTALS: 16104 17075 17466 50645 =TOTAL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 134.1 142.2 145.4 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS: 1.25 X 0 = 0 VA C=OONTINUOUS LOADS, OTHER: 1.25 X 1934 = 2418 VA M=MOTOR LOADS (INCL LGST): 1.00 X 1512 = 1512 VA LARGEST. VA: 0.25 X 0 = 0 VA R=RECEPTACLES: 1ST 10K: 1.00 X 1080 = 1080 VA BALANCE: 0.50 X 0 = 0 VA K=KITCHEN LOADS: OTY: 23 0.65 X 46119 = 29977 VA N=NONCONTINUOUS LOADS, OTHER: 1.00 X 0 = 0 VA NOTES. (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 34987 VA = 97.1 AMPERES (N)PANEL "B" VOLTS:120/208V PHASE: 3 A.I.C. RATING: 10,000AMP MAIN: LO MOUNTING: SURFACE WIRE. 4 BUSSING: 400 AMP LOAD ' A -VA B-VA C-VA BKR CT CT BKR A -VA B-VA C-VA • LOAD LIGHTING L 600 20/1 1 2 20/1 1100 R HOOD LIGHTING L 200 20/1 3 4 20/1 F 720 R ORDER MONITOR HOTDOG STEAMER K 1800 20/1 5 6 20/1 1000 K WALK-IN COOLER SANDWICH TABLE K r 1176 20/1 7 8 20/2 1040 K COOLER COMP FOOD WARMER K 1008 20/1 9 10 - r 1040 K -- REACH-IN REFRIGERATOR K 660 20/1 11 12 20/1 1000 K WALK-IN FREEZER RTU-6 M 3879 50/3 13 14 20/2 1040 K FREEZER COMP -- M ' 3879 -- 15 16 - 1040 K --- -- M ' 3879 -- 17 18 20/1 900 R MENU MICROWAVE K 1602 20/2 19 20 20/1 1200 K FOOD WARMER -- K r 1602 - 21 22 20/1 SPARE DINING AREA2 RECEPTACLES K R 540 20/1 23 24 20/1 r 360 R KITCHEN AREAEASTSIDE RECEPT FOOD WARMER K P 717.6 20/2 25 26 20/1 1440 K D-CARBONATOR K ' 717.6 -- 27 28 20/1 360 R TEL BACKBOARD MANAGER OFC R ". 1080 20/1 29 30 20/2 1534 K CHICKEN HOLDING CABINET MANAGER OFC R� 540 20/1 31 32 - ~ 1534 K --- REMOTE CONDENSER K 270.4 15/2 33 34 20/1 820 C GAS HEATERM/ATER FILTER -- K ' 270.4 - 35 36 20/1 576 K FREEZER BASE PANEL "C" R r 16104 100/3 37 38 100/3 r 12363 N PANEL "Al' R ' 17075 -- 39 4D - P 14874 N --- R r 17466 - 49 42 - ' 16916 N --- PHASE TOTALS: 44336 43606 47981 135923 =TOTAL CONNECTED LOAD,VA (FOR DEMAND LOAD SEE BELOW) PHASE AMPERES: 369.2 363.1 399.5 'DEMAND LOAD CALCULATION: L=LIGH11NG LOADS: 1.25 X 800 = 1000 VA C=CONTINUOUS LOADS, OTHER: 1.25 X 820 = 1025 VA M=MOTOR LOADS (INCL LGSTy: 1.00 X 11637 = 11637 VA LARGEST, VA: 0.25 X 0 = 0 VA R=RECEPTACLES: 1ST 10K: 1.00 X 10000 = 10000 VA BALANCE: 0.50 X 45705 = 22853 VA K=KITCHEN LOADS: OTY: 20 0.65 X 22608 = 14825 VA N=NONCONT1NUOUS LOADS. OTHER: 1.00 X 44153 = 44153 VA NOTES: (P=PANEL. INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 105493 VA = 292.8 AMPERES (E)PANEL "D" VOLTS:120/208V PHASE: 3 A.I.C. RATING: 10,000 AMP MAIN: LO MOUNTING: SURFACE WIRE: 4 BUSSING: 225 AMP LOAD ' A -VA B-VA C-VA BKR CT CT BKR A -VA B-VA C-VA " LOAD RTU-1 M 1872 25/2 1 2 20/1 1250 L LIGHTING -- M 1872 -- 3 4 20/1 1250 L LIGHTING RTU-2 M 1872 25/2 5 6 20/1 1050 L LIGHTING •-- M P 1872 -- 7 8 20/2 950 L LIGHTING RTU-3 M 2520 35/3 9 10 20/1 950 L LIGHTING --- M r 2520 -- 11 12 20/1 1150 L LIGHTING M' 2520 - 13 14 20/2 360 R CONVENIENCE OUTLET RTU-4 M 2520 35/3 15 16 20/1 0 SPARE -- M ' 2520 -- 17 18 20/1 0 SPARE M ' 2520 -- 19 20 45/3 3720 M RTU-5 ROOF RECEPTACLES R 540 20/1 21 22 - ' 3720 M --- CONVENIENCEOUTLET R 900 20/1 23 24 - 3720 M -- MUA-1 8 MUA-2 M 1830 20/3 25 26 20/3 1740 M CU-3 M 1830 - 27 28 - ' 1740 M -- - M 1830 -- 29 30 - ' 1740 M --- SPARE 20/1 31 32 20/3 2568 M CU-2 SPARE 20/1 33 34 - ' 2568 M - SPARE 20/1 35 36 - 2568 M -- EF-3 M 1321 20/3 37 38 20/1 SPARE -- M r 1321 - 39 40 20/1 SPARE -- M P 1321 - 41 42 20/1 SPARE PHASE TOTALS 22523 20831 21191 64545 =TOTAL CONNECTED LOAD.VA (FOR EMAND LOAD SEE BELOW) PHASE AMPERES: 187.5 173.5 176.5 'DEMAND LOAD CALCULATION: L=LIGHTING LOADS: 1.25 X 6600 = 8250 VA C=CONTINUOUS LOADS, OTHER: 1.25 X 0 = 0 VA M=MOTOR LOADS (INCL LGST): 1.00 X 56145 = 56145 VA LARGEST, VA: 0.25 X 0 = 0 VA R=RECEPTACLES: 1ST 10K: 1 00 X 1800 = 1800 VA BALANCE: 0.50 X 0 = 0 VA K=KITCHEN LOADS: CITY: 0 1.00 X 0 = ' 0 VA N=NONCONTINUOUS LOADS. OTHER: 1.00 X 0 = 0 VA NOTES: (P=PANEL, INCL. IN ABOVE) TOTAL N.E.C. DEMAND LOAD = 66195 VA = 183.7 AMPERES 4 CMy of Tukwila PANELBOARD SCHEDULE SCTSE: 1 Jduibs. CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4 # PIOt a I}vson o. . K rp E.ny.viomng. 14¢ 914 E. KATELLA AVENUE ANAHEIM. CALIFORNIA 92805 P (714) 305.1035 FOIL} 385.'834 ".wPUmppoi ccm _ STAMP �G e.� S 'F � 02 D A. A< _E W A Sy G,g, /cam t 0 s y 34218 p - ecis/A L NT E EN'\a� EXP. 03/19/20 PROJECT NAME/ADDRESS: Joflibss TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI PEI SHEET CONTENT PANEL SCHEDULE SHEET NO E-600 �uq-osa9 619 C FINISHED FLOOR CEILING 12 0 0 0 0 0 0 0 m 13 F.E.C. SUPPLIED AND INSTALLED ANSUL R-1D2 STORAGE TANK WITH ENCLOSURE AND MICROSWITCH. ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED 4" OCTAGONAL JUNCTION BOX WITH 1/2"0 EMPTY E.M.T. TO EXTEND TO +12" ABOVE RNISHED CEILING. F.E.C. SUPPLIED AND INSTALLED FLUSH MOUNTED MANUAL PULL DEVICE. F.E.C. SUPPLIED AND INSTALLED CONDUIT AND PULL CABLES, F.E.C. SUPPLIED AND INSTALLED WET CHEMICAL LINE FROM ENCLOSURE TO EXHAUST HOOD PLENUM AND COOKING EQUIPMENT BELOW EXHAUST HOOD. ELECTRICAL CONTRACTOR SUPPUED AND INSTALLED CONDUIT AND WIRING. ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED JUNCTION BOX. ELECTRICAL CONTRACTOR SUPPUED WIRING TO EXTEND TO BUILDING ALARM SYSTEM. ELECTRICAL CONTRACTOR SUPPLIED WIRING TO EXTEND TO POWER SOURCE. F.E.C. SUPPLIED MANUAL RESET RELAY TO BE INSTALLED BY ELECTRICAL CONTRACTOR. F.E.C. SUPPLIED GAS SOLENOID VALVE TO BE INSTALLED BY PLUMBING CONTRACTOR. ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED CONTACTORS (SHALL SHUT-OFF ALL ELECTRICAL DEVICES LOCATED UNDER THE EXHAUST HOOD). ELECTRICAL CONTRACTOR SUPPLIED AND INSTALLED ON/OFF POWER SWITCH. FIRE SUPPRESSION SYSTEM DETAIL NOTE: PROVIDE ENCLOSURE TO MATCH WALL RATING IF PANEL OCCURS IN FIRE RATED WALL. CONTRACTOR SHALL FIELD VERIFY WITH ALL LOCATIONS. STEEL STUD BUILDING STRUCTURE ENGRAVED NAMEPLATE ON FRONT PANEL TYPEWRITTEN CIRCUIT DIRECTORY LOCATED ON INSIDE FACE OF DOOR HINGED, LOCKABLE AND FLAT DOOR FLUSH LOCK HANDLE AND MECHANISM BOLT TO STRUCTURE, BOTH SIDES, WITH 114" DIAMETER BOLTS, THREE PER SIDE AND FRAME , AS REQUIRED INCOMING POWER 120V.60HZ.1 PH. r r I ^. • � a COIL SERVICE I LEp 3 SWITCH / 1 TEMPERATURE I J (CONTROL ___J (PENN MODEL 120V SOLENOID RA19BBC•2) COIL & VALVE (SPORLAN MODEL M MKC1 & E6S130) r TERMINAL BOX ON COIL ✓ Z_ BLOWER G FAN(S) MOTOR 1 T & LIGHPILOT/ SWITCH 0 L UGHT r EVAP COIL 2 Nt NTS JSNb.. CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP PL =RC YIT54IU V.k G ENfi1NEE FFPINO a d,5ioo of Plump En9bteNn9, Inc. 914 E. KATELLA AVENUE ANAHEIM, CALIFORNIA 92505 P 171113151135 W1413/5-1694 STAMP EKP. 03/19/20 PROJECT NAME/ADDRESS Jdlib.. TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS! ISSUE DATE NO. DATE DESCRIPTION 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL INCOMING POWER 230P208V.60HZ. 1 PH. L2 WMPLIANNC EJOJFWITW NFPA 70 - LBO SCP 17 619 Cky or Ttx NI+ QULLAWiG DIN BK1n FUSED DISCONNECT SWITCH BY ELECTRICIAN 2P30t3oar REVIEWED CODE COMPL APPROVE ELECTRICAL BOX ON EVAP COIL. COORDINATE FINAL CONNECTIONS INCLUDING MEANS FOR DISCONNECT WITH REFRIGERATION INSTALLER. SEP172 JOB NUMBER MEP # 1901069 FOR ANF DII )19 City of Tukurila BUILDING DI. ISI DRAWN BY PEI CHECKED BY PEI SHEET CONTENT ELECTRICAL DETAILS RECESSED MOUNTING PANEL 4 COOLER EVAPORATOR COIL 3 FREEZER EVAPORATOR COIL 1 SHEET NO E-700 NTS NTS NTS COMcheck Software Version 4.1.1.0 illInterior Lighting Compliance Certificate Protect Information Energy Code. Project Tile. Project Type: 2015 IECC ,IOLLIBEE TUKWILA Alteration Construction Site: OwnetrAgaril: WESTFIELD SOUTHCENTER CORTLAND MORGAN ARCHITECT 1374 SOUTHCENTER MALL 711 N. FIELDER: RD. TUKWILA. WA 98188 ARLINGTON-Tx 16012 Allowed interior Lighting Power A Area Category DesignariConaeinor PLUMP GROUP 914 E KATELLA AVE ANAHEIM, NY 92805 T143851835 8 Flout Attie (a1 C. D Attend Allowed Watts WatsHR2 roXC) 1-KITCHEN (Common Spas Typoe:Food Preparation) 2-MANAGER'S OFFICE (Common Space Types:O8lce • Enclosed) Proposed Interior Lighting Power A Fixture ID : Description 1 Lamp 1 Wattage Per Lamp / Ballast 839 1.21 52 111 TOW Allowed Wens: 1015 58 1013 H C 6 E lampaf Not Flxhlre (C X 0) Fixture Fixtures Watt. KITCHEN (Cnmmnn Spar4Type&Fnod Preparation Alp sq.R3 LED 1: NAE: 2X4 TBAR LED RECESSED LIGHT: LED Panel 41 W. MANAGERrS-QEE(GE(S4omtO BABI* Tvpes:O6te - Enclosed 52 aq.0,1 LED 2 B&BE: 2X2 TEAR LED RECESSED LIGHT: LED Other Fixture Unit PAW 1 1 15 42 540 2 25 Taal Prbpoeed Was nterior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed intenor lighting alteration project represented in this document is consistent with the building plans, specifications. and other calculations submitted with this permit application. The proposed interior lighting tystems have been designed to meet the 2015 IECC requirements In COMchetk Version 4.1.1.0 and to comply with any dppbCable mandatory requirements listed In the Inspection Checklist. Adel POVrrharlf- Electrical Engineer 01-21-2019 Name -Yale Signature bete Project Tltie: JOLUSEE TUKWILA Report date: 01/21119 Data filename: J:\Gary Wang\M.1901069Jaliiboe Tukwllla\ACAD\ElecMcal\COMCHECK.CCk Page 1 of 5 COMcheck Software Version 4.1.1.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text In the 'Comments/Assumptions" column Is provided by the user in the COMcheck Requirements screen. for each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception Is being claimed. Where compliance Is itemized in a separate table. a reference to that table is provided. Section At Plan ReVlew dt.Ra544_:.... C193.2 Plans, specifications. and/or !PRO calculations provide ail Intgmlation with which compliance can be determined for the Interior lighting and elecklcai systems and equipment and document where exceptions to the standard are claimed. Information provided should Include Interior lighting power calculations, wattage of bales and ballasts, transformers and control devices. Complies? • CommentsfAssumptlons CDComplles Requirement wlu be incr. Dooes Not ONot Observable Location en plans(spec: SHEET E400 ONot Applicable Additional Comments/Assumption: 1.1 ;High Impact (Ter 1) ,2s{Madlum Imps¢ ITlar 2) --- _'Low 1°E.1 t(Tisr 31 ;roject Title: JOLL18EE TUKWILA ate filename: ):\Gary Wang\M.1901069 jolllbee TukwllIMACAD\Elecfcal\COMCHECK.cck Mahan !. 6 ltsq.t6 Final Inspection Complies? Comments/Amu' mptlons C303,3. Furnished O&M instructions for C408.2.5. systems and equipment to the 2 building owner or designated jfi17j .representative. °Complies :Requirement will be met. °Does Not ONot Observable; °Not Applicable C405.4.1 ;interior Installed lamp and fixture :°Complies [FI18]1 jlightlng power is consistent with what Oboes ;is shown on the approved lighting ;pans. demonstrating proposed watts °Not fare less than or equal to allowed '.Not !watts. ;See the interior Lighting fixture 'Onside Fovaaes. Not • Observable Applicable C406.2.5. !Fumished as -built drawings for 1 : electric power systems within 90 days [FI1611 of system acceptance. .Complies Dopes Not °Not Observable ONot Applicable Requirement will be met. C408.3 ;Lighting systems have been tested to [F133]' lensure proper calibration, adjustment, 'programming, and operation. i °Complies Oboes Not ONot Observable '°Not Applicable Requirement will be met. LocaNen on plenslspec: SHEET MOO Additional Comments/Assumptions: -- _._....._.. Milian Impact (Tier 1) liTMeMedlum Impact (filer 2) 37Low Impact (Tier 3) Project Title: JOLUBEETUKWILA Report date: 01/21/19 Data filename: ):\Gary Wang\M.1901069 Jollibee TukwlllaIACAD\ElectrkaRCOMCHECK.cck Page 4 of 5 Report date: 01)21119 Page 2 of 5 Section 4 Roughdn Electrical Inspection C405 2,1 Lighting controls installed to uniformly 1E4151' reduce the lighting load by at least S0%. C405.2.1 Occupancy sensors installed in (E41811 required spaces. 15403:2i, Independent lighting controls installed C44€2:21 per approved lighting plans and all 3' " "` `.manual controls readily accessible and (EL23Jt visible to occupants. C4054:2i' AutOmBNc controls to shut on all 1 - ' building lighting installed in all RL22Jx` buildings. C405.2. t; Daylight zones provided with (EL/6r . Indivldual controls that control the lights Independent of general area .lighting. C405.2.3, Primary sidelighted areas are C405.2.3. equipped with required lighting 3, controls. C405.2.3. 2 ik2o)1 Complies? OCompeos °Does Not ONot Observable ONot Applicable Comnwme/Aseuutptions Requirement will be met Location on plans/spec. SHEET 6400 Lleomplles Requirement will be met. ❑Goes Not ONot Observable ['Not Applicable °Complies Requirement will be met. °Gees Not Location at glens/spec: SHEET 6400 ONot Observable ONot Applicable Location on plans/spec SHEET 6400 °Compiles Requirement will be met. °Does Not []Not Observable ONot Applicable °Compiles Ogees Not ONot Observable Location on plans/spec: SHEET E400 ONot Applicable °Complies Exception; Requirement does not apply. °00e5 Not ONot Observable 'satin" on planalepac: SHEET 6400 °Not Applicable Location on plansispece SHEETE400 Requirement will be met. C405.2.3, Enclosed spaces with daylight area OCompliez Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors C7 1, are equipped with required leghtlng Location on plans/spec SHEET E900 e405.2.3. controls. ONot Observable 3 IEL21)t C405.2.4 Separate lighting control devices for (E141' specific uses Installed per approved lighting plans. C405.2.4 Additional intenor lighting power I460 allowed for special functions per the approvedlighting plans and Is automatically controlled and separated from general lighting. C405.3 Exit signs do not exceed 5 watts per (EL61t :face. Dom Not ONot Applicable °Complies Requirement will be met. Oboes Not ONot Observable Location on pleat/ton: SHEET E400 ONot Applicable °Compiles Requirement will be met °Does Not ONot Observable ONot Applicable °Complies °Does Not °Not Observable ONot Applicable Laotian on plans/spec: SHEET 6400 Requirement w10 be met. Location en plans/env SHEET E400 Additions, Cen s•bts/Aswmpttotra: l l 'High Impact (Tier 11 2 Med,iom impact;Tier 27 3 LOW In10ac111 ei 3i Project Title: JOWUBEE TUKWILA Data filename: ):‘Gary Wang\M.1901069 Jolllbee Tukwltla AcAP\Electneal\COMCHECK.ccK Project Title: IDU.IBEE TUKW ILA Data filename: J:1Gary Wang\M.1901069 Jollibee TukwillalACAD\EleCtdcalICOMCHECK.cck Report date: 01121/19 Page 5 of 5 Report date: 01/21/19 Page 3 of 5 qr. ). • : iSGr vl;i. or,1 p 40p City of Tukwila INDOOR LIGHTING COMPLIANCE SCALE: NONE Joflibss CITY SUBMITTAL BUILDING DEPARTMENT REVISIONS HAVE NOT BEEN ADDED TO THESE CONSTRUCTION DRAWINGS. THE ARCHITECT AND HIS CONSULTANTS ASSUME NO RESPONSIBILITY FOR CONSTRUCTION BIDS OR CONSTRUCTION PERFORMED FROM THESE DRAWINGS. MEP 4 OP PLUFWGIROUP n.:ai fie c •uue e a a ViviSiun of Hump Ercnxixarine, Inc 914 E- KATELLA AVENUE ANAHEIM. CALIFORNIA 92605 P17141345.1635 F(7141 365-1944 vmebnppwpwa STAMP p,R A A. p G�OF WASij, . A c..A o se l_ -2, ,p 34218 % 1.,"1,3,s E DNA Li ENc,` EKP. 03/19/20 PROJECT NAME/ADDRESS: Jdlib.. TUKWILA, WA SPACE 372 & 368 LEVEL 1 WESTFIELD SOUTHCENTER 1374 SOUTHCENTER MALL TUKWILA, WA 98188 REVISIONS / ISSUE DATE NO. DATE DESCRIPTION 3 061819 1ST PERMIT SUBMITTAL 4 061819 HEALTH SUBMITTAL JOB NUMBER MEP # 1901069 DRAWN BY CHECKED BY PEI I PEI SHEET CONTENT INDOOR COMPLIANCE LIGHTING SHEET NO E-800