Loading...
HomeMy WebLinkAboutPermit EL19-0595 - SABEY SDC4 ACCESS CONTROL - CONVERT ACCESS CONTROL SYSTEM TO LENEL, ADD ENCLOSURES, POWER SUPPLIES AND CIRCUIT BOARDS ETCSABEY SDC4 ACCESS CONTROL 3433 S 120 PL EXPIRED 01/19/2020 ELI 9-0595 Parcel No: Address: City of Tukwila a Department of Community Development 630O6outhcenterBoulevard, Suite #1UU Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1023049081 3433SlZOTMPLBLDG 4 ELECTRICAL OTC PERMIT Project Name: SABEY SDC4 ACCESS CONTROL Permit Number: EL19'0595 Issue Date: 7/23/2019 Permt Expires Ori: 1/19/2020 Owner: Name: Address: SABEY CORPORATION 12201TUNWILA|NTLBLVD 4TH B' SEATTLE, WA, 98168 Contact Person: Name: BURT MAXWELL Address: 12500 AURORA AVE N , SEATTLE, WA 98133 Contractor: Name: [UCHRAm|N[(ELECTR|CAU Address: PVBOX J35Z4'SEATTLE, WA, gD133 License No: [OCMR|~O805 Lender: Name: Address: ''' Phone: (206) 963-3517 Phone: (206) 367-1900 Expiration Date: 4/11/2020 DESCRIPTION OF WORK CONVERT EXISTING ACCESS CONTROL SYSTEM FROM AMAG TO LENEL. INSTALL NEW ENCLOSURES, POWER SUPPLIES, AND CIRCUIT BOARDS. RUN ASSOCIATED CABLING WHERE NECESSARY. PERFORM (1) 120VAC CONNECT, 9 CONTROL UNITS, 33 DEVICES, APPROX 4000 SF Valuation of single family: $0.00 Valuation of mf/comm: $80,126.00 Type of Work: LOW VOLTAGE Fees Collected: $1,477.02 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEYVIEW Current Codes adopted by the City of Tukwila: International Buliding Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: D 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date:? Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: or olice use onl 6tg ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION /33 Site Address: 3.3"1 S 120TH ST. TUKWILA WA 98168 Suite Number: King Co Assessor's Tax No.: Tenant Name: SABEY SDC4 ACCESS CONTROL J# 514771 PROPERTY OWNER _ Name: BURT MAXWELL Name: SABEY (J# 514771) City: SEATTLE State: WA Zip: 98133 Address: 3344 S 120TH ST. Email: BMAXWELL@COCHRANINC.COM City: TUKWILA State: WA Zip: CONTACT PERSON — person receiving all project communication _ Name: BURT MAXWELL Address: 12500 AURORA AVE N City: SEATTLE State: WA Zip: 98133 Phone: (206) 963-3517 Fax: Email: BMAXWELL@COCHRANINC.COM New Tenant: Floor: Yes ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: COCHRAN, INC. Address: 12500 AURORA AVE N City: SEATTLE State: WA Zip: 98133 Phone: (206) 367-1900 Fax: Contr Reg No.: COCHRI*088JS Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 80,126 Scope of Work (please provide detailed information): CONVERT EXISTING ACCESS CONTROL SYSTEM FROM AMAG TO LENEL. INSTALL NEW ENCLOSURES, POWER SUPPLIES, AND CIRCUIT BOARDS. RUN ASSOCIATED CABLING WHERE NECESSARY. PERFORM (1) 120VAC CONNECT 9 CONTROL UNITS, 33 DEVICES, APPROX 4000 SQ FT. Will service be altered? Ej Yes [j No Adding more than 50 amps? CD Yes [Z] No Type of Use: SECURITY, LOW VOLTAGE Type of work: 0 New 0 Addition 0 Service Change EJ Remodel [2] Tenant Improvement Low Voltage 0 Generator 0 Fire Alarm El Telecommunication 0 Temporary Service Property Served by: [1] Puget Sound Energy 0 Seattle City Light HAApplicationaorms-Applications On Line \ 2014 Applications\Electrical Permit Application Revised t-1-14.docx Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $8L90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $1L55 ea. ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***ENFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% 'TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT' HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: KIM ZIN Date: 03/01/2017 Day Telephone: (206) 368-3236 Mailing Address: 12500 A " ORA AVE N SEATTLE, WA 98133 City State Zip H:.Applications\Forms-Applications On Line \2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Pave 2nf2 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,477.02 EL19-0595 Address: 3433 S 120TH PL BLDG 4 Apn: 1023049081 $1,477.02 ELECTRICAL $1,406.69 PERMIT FEE MULTI-FAM/COMM R000.322,101.00 00 0.00 $1,406.69 TECHNOLOGY FEE $70.33 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18178 R000.322 900.04 00 0,00 $7033 $1,477.02 Date Paid: Tuesday, July 23, 2019 Paid By: COCHRAN INC (ELECTRICAL) Pay Method: CHECK 14365 Printed: Tuesday, July 23, 2019 1:47 PM 1 of 1 12/3/2019 City of Tukwila Department of Community Development BURT MAXWELL 12500 AURORA AVE N SEATTLE, WA 98133 RE: Permit No. EL 19-0595 SABEY SDC4 ACCESS CONTROL 3433 S 120TH PL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/19,'2020. Based on the above, you are hereby advised to: I) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/19/2020, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: ELI9-0595 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 COCHRAN INC Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries A-4 1 nciex 1 kip 1\1\'1,&1 Workplace Rights Trades & Licensing COCHRAN INC Owner or tradesperson Principals COCHRAN, ROBERT L COCHRAN, GORDON W COCHRAN-OLSEN, LEEANN G COCHRAN, ROBERT L, AGENT Doing business as COCHRAN INC WA UBI No. 578 042 134 PO BOX 33524 SEATTLE, WA 98133-0524 206-367-1900 KING County Business type Corporation Governing persons RAE BROWN GORDON W COCHRAN; ROBERT L COCHRAN; DONNA J HEITMAN; Certifications & Endorsements License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. COCHRI*088JS Effective — expiration 04/10/1992— 04/11/2020 Designated administrator Heywood-cochran, Michael D Active. Meets current requirements, License type License no. Master Electrician HEYWOMD901 RF Bond TRAVELERS CAS & SURETY CO Bond account no. 081S103533100BCM $4,000.00 Received by L&I Effective date 01/08/2001 04/09/2001 Expiration date Until Canceled Savings Help us improve // 1 • / TrIT—C'70/1An 1 IA 0...T Tn—r‘nr,T_IDT*CO Q TC' Pre A 1.17— P-) 1 0 COCHRAN INC No savings accounts during the previous 6 eriod. License Violations Infraction no. EZINS00889 Issue date 05/17/2019 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Failing to ensure an electrical installation is in strict conformity with electrical statutes, rules, regulations, and ordinances for safety to life and property by working without a permit in the jurisdiction of a city or town or electrical supply agency which has established an electrical inspection jurisdiction pursuant to RCW 19.28.010 or RCW 19.28.141. Infraction no. ETUCP00595 Issue date 10/23/2018 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Failing to obtain an electrical/telecommunications work permit and post the permit or permit number on the jobsite, or post a provisional electrical work permit prior to beginning the electrical/telecommunication Installation or alteration. Infraction no. ESACE00509 Issue date 04/06/2017 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Employing an individual for the purposes of chapter 19.28 RCW who does not possess a valid certificate of competency or training certificate to do electrical work. Infraction no. ERADJ00249 Issue date 11/05/2013 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Employing an individual for the purposes of chapter 19.28 RCW who does not possess a valid certificate of competency or training certificate to do electrical work. Satisfied RCW/WAC 19.28.010 RCW Violation amount $1,000.00 Satisfied RCW/WAC WAC 296-46B-901(5) Violation amount $250.00 Satisfied RCW/WAC 19.28.271 RCW Violation amount $250.00 Satisfied RCW/WAC 19.28.271 RCW Violation amount $250.00 Page 2 of 3 Help us improve httns://secureini.wa.poviverifv/Detail.asnOUBI=5780421348LLIC=COCHRI*088JS&SAW= 7/23/2019