Loading...
HomeMy WebLinkAboutPermit EL19-0824 - KAY RESIDENCE - PHOTO VOLTAIC SYSTEM WITH A LINE SIDE TAPKAY RESIDENCE 4727 S 144T" ST ELI 9-0824 Parcel No: Address: Project Name: CityTukwila of ent of Community Det 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206'431'3670 Inspection Request Line: 206'438'9350 Web site: htto://www.TukwilaWA.eov ELECTRICAL PERMIT 0040000505 Permit Number: EL19'0824 4727 S 144TH ST KAY RESIDENCE Issue Date: 12/5/I019 Permit Expires On: 6/3/2020 Owner: Name: Address: KAY MICHAELA+MICHAELJ 4727S144THST,TUKVV|b\WA, 98168 Contact Person: Name: NE|LGOVVL[R Address: Contractor: Name: Address: License No: Lender: Address: 2909FIRST AVE S'SEATTLE, WA, 98134 SOLTERRA GLOBAL LLC (ELECT) l9IOFIRST AVE S'SUITE ZO1, SEATTLE, WA98134 SOLTEGL838BS ''' Phone: (425) 773-6838 Phone: (206) 462-1103 Expiration Date: 1/18/2021 DESCRIPTION OF WORK: INSTALLATION OF 12.21 KW PHOTO VOLTAIC SYSTEM WITH A LINE SIDE TAP. Vaivation of single family: $15,000.00 Valuation of mf/comm: $0.00 Type of Work: SERV CHNG Fees Collected: $160.68 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: InternatonaI Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 Nationat Electrical Code: WA Cities Electrical Code: WAC 296-4613: WA State Energy Code: 2017 2017 2017 2015 �� Date: �°~~ �� � � 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and /eetothe cyitions attached to this permit. Signature: Date: /�� PhntName: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipnient shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax, **Please Print** SITE LOCATION King Co Assessor's Tax No.: 0040000505 Site Address: 4727 S 144th st Tukwila WA 98168 Suite Number: Tenant Name: Michaela Kay New Tenant: PROPERTY OWNER Name: . Nei] Gowler Address: 2909 1st AVE S Name:. : Michaela Kay Address: 2909 1st AVE S Contr Reg No.: SOLTEGL83ass Exp Date: 1 22 Address: 4727 S 144th st City: Seattle State: WA City:State: Tukwila WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: . Nei] Gowler Address: 2909 1st AVE S City: Seattle State: WA Zip: 98134 Address: 2909 1st AVE S Contr Reg No.: SOLTEGL83ass Exp Date: 1 22 Tukwila Business License No.; City: Seattle State: WA Zip: 98134 Phone: 425-773-6838 Fax: Email: ngowler@solterra.com Floor: 0 __Yes []..No ELECTRICAL CONTRACTOR INFORMATION Company Name: SolTetra Global LLC Address: 2909 1st AVE S City: Seattle State: WA Zip: 98134 Fax: Phone:Fax: Contr Reg No.: SOLTEGL83ass Exp Date: 1 22 Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 15,000 Scope of Work (please provide detailed information): Ins a 2.21 kw PV s stem with a line side tap Will service be altered? El Yes El No Type of Use: Type of work: O New El Addition El Service Change El Remodel 111 Tenant Improvement El Low Voltage El Generator LI Fire Alarm 0 Telecommunication 0 Temporary Service Adding more than 50 amps? ill Yes E No Property Served by: O Puget Sound Energy El Seattle City Light WAPermit CenternApplications-liandoutsWentnit Applications \ PDFsSElectrical Permit Application Revised 1.1 7-I9.docx RESIDENTIAL NEW RESIDENTIAL SERVICE 0 New single family dwellings . $180.00 (including an attached ganage) 0 Garages, pools, spas and outbuildings $120.00 ea E Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES E Service change or alteration $120.00 (no added/altered circuits) n Service change with added/altered circuits $100.00 number of added circuits $10.00 ea O Circuits added/altered without service change $60.00 (up to 5 circuits) • Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea O Meter/mast repair $80,00 O Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES • Temporary service (residential) $60.00 O Temporary service (generator) $90.00 El Manufactured/mobile home service $100.00 (excluding garage or outbuilding) • Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: /teda Bt.ti-EVA. Date: 9/23/2019 Print Name: Neil Gowler Mailing Address: 2909 1st AVE S WAPermit Center \ Applications-HandoutsTcrmit AppZications PDF's Electrical Permit Application Revised 1 -17-19.docx Day Telephone: 425-773-6838 Seattle City WA State 98134 Zip Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT 1 QUANTITY PermitTRAK :itikt.,.'ilt 4:,:lt,IiiNqifip,;:-VgiigifINVIII, '':y6Ifirl'e4. :r,,,,.:,,bira-v .. . _. ,. „,...„,,z--1.4-' ------,--- ,,,--, I PAID ..„,,,..,.!,,,,,i4:. Elli9 Address:16824Sri. '6,1-14fkilST 5r. __ __ _ - _ - - ::'' '' ,,,,,,2'. ri.„..4646(i6Tiik`;-' ---.' ' '''''' PH* -,,,r T':: ': ':-41111:V$71:60:;6431-1 Credit Card Fee „_ , .. $4.68 ' Credit Card Fee R000.369.908.00.00 1 0.00 $4.68 ELECTRICAL --' ' Tr ' $150.00 PLAN CHECK FEE R000.345.832.00.00 0.00 $30.00 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $120.00 TECHNOLOGY FEE $6.00 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18752 R000.322.900.04.00 0.00 $6.00 $160.68 Date Paid: Friday, October 04, 2019 Paid By: NEIL GOWLER Pay Method: CREDIT CARD 04204G Printed: Friday, October 04, 2019 11:48 AM 1 of 1 CRWYSTEMS 0 0 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206'433-1870 CITY OF TUKWILA Date: 10/04/2019 11:48:06 AM CREDIT CARD SALE VISA CARD NUMBER: **********6590 K TRAN AMOUNT: $160.68 APPROVAL CD: 042046 RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy INSPECTION NO. INSPECTION RECORD Retain a copy with permit P MITNO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Typ n ec on: Mr.— auhaw ' Address: 4/ 717 i . e Called: Special Instructions: Date Wanted: /1 a.i . p.m. Requester: Phone No: Approved per applicable codes. - 1 1 Corrections required prior to approval. COMMENTS: n pector Date: REINSPECT, N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PROrIOSED 12.21 KW DC (7YSTEM (STC) AT 4727 S 144T Pv.1.0 PV -1.1 PV -2.0 PV -2.1 PV -3.0 PV -3.1 PV -4,0 PV -4.1 Attached Plot Plan Photovoltaic Layout Project Notes Racking Layout Mounting Details Fire Labels & Equipment Elevation Fire Placard Conduit Run & Grounding Details 3 Line Diagram Manufacture Spec. Sheets OCCUPANCY GROUP: R-3 TYPE OF CONSTRUCTION: TYPE V -B AUTHORITY HAVING JURISDICTION: TUKWILA ASSESSORS PARCEL NUMBER: #0040000505 NUMBER OF STORIES: 2 -Story ROOF PITCH: 30.5' 1 Sheet Index & Site Information Scale: NTS 2 AHJ Notes Scale: NTS (N) (33) Hyundai HIS-5370RI (N) (33) SolarEdge P400 (HD) Optimizers N 3 Plot Plan Scale: 1" = 40' 4'.S ST, TL KWI LA`WA 98168 4727 S 144th St 120'-B" To N L 0 w IONS No r •,: les sraP 2F naoe i0 Inc scope 0) worw w11n0U1 D G' aooroval Of the Tukwila Building Division NOTE: Revisions will require a new plan submittal and may include additional plan review. /1 a 0 m N! Plan renew approval Issub)e to omissions. Approval of consmalion aoormcnIs does 1W authorize the violation of any adopted code or ordmarce. Receipt of approved Field Copy and ronolt s IS aqui ro a) 0 w ///r Duo: /1 S- 2n I City of Tukwlo BUILDING DIVISION (5) SolarEdge TechnologiesSE11400HiUS(2400) (N) 60A Utility Fused AC Disconnect #1 (N) Utility Performance Meter (E) Standalone Meter (E) 200A MSP w((E) 200A Main Break (Inside Garage) (E) Single Family Ho 36'-11" - (E) Fence (N)JUNCTION BOX (E) Fence 120-7' City of Tukwila UILDING D)VISIONJ Project # z 0 0 z Ir 0 F U CC z 0 SEPARATE PERMIT RE2UIRED FOR: Mechanical Electrical Plumbing g Gas Piping City of Tukwila BUILDING DIVISION 0 0 to m tD 0 W J 0 0 5- 0 V?� 0) N x z 0 Q 2 tY 0 z 10 } V1 NN vN tnOn�5Eo a PEHH Nmzw 10� 0 UVm 12 3,� N � I TA min 0 RECEIVED CITY OF TUKWILA d U. �zc�0) zcoNo OCT 01n1p °3o0IN m PERMIT CENTER o YrN , yflZ 1 r -Q 0 REVISION BLOCK 0 DESCRIPTION DATE Inita/DraftofPiens 95/19 Roof Access Point Property lines Fence Line Block Wall Conduit On Roof Conduit In Attic Conduit In Trench 0 PROTECT: Kay, Michael 916(19 01` SHEET PV -1.0 2017 NATIONAL ELECTRICAL CODE Applicable Codes Scale: NTS CODE BOOK: BREAKER SIZES: WIRE AMPACITY TABLE: MAX SYSTEM VOLTAGE CORRECTION: NUMBER OF CONDUCTORS CORRECTION: AMBIENT TEMPERATURE CORRECTION: AMBIENT TEMPERATURE ADJUSTMENT: DC GROUNDING ELECTRODE CONDUCTOR: AC GROUNDING ELECTRODE CONDUCTOR: RACK GROUNDING ELECTRODE CONDUCTOR: MAXIMUM OCPD (120% RULE): 2 2017 NEC® NEC 240,6(A) NEC 310.15(8)(16) NEC 690.7(A) NEC 310.15)B)(3)(A) NEC 310.15(B)(2)(A) NEC 310.15(B)(3)(C) UNGROUNDED DC SYSTEM NEC 250.50 NEC 690.47(B) NEC 705.12 Electrical Code References Scale: NTS 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 11026. 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 69031(A)6(C), NEC 310.15(B)(3)(C), AND NEC TABLE 310.15(BI(2)(A), 3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 4. ADDITIONAL ACDISCONNECT(S) SHALL BEPROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 5. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 6, ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE 3 Equipment Location Scale: NTS 1. LOAD -DDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH NEC 705.12(B). 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120% OF BUSBAR RATING NEC 705.12(32)(31. 3. WHEN SUM OF THE PV SOURCES EQUALS >100% OF BUSBAR RATING, P0 DEDICATED BACKFFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD NEC 705.12(0)(2)(3). 4. AT MULTIPLE PV OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVER CURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVER CURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705,12(D)(2)13)(C). 5, FEEDER TAP INTER CONNECTION (LOAD SIDE)ACCORDING TO NEC 705,12)D52)(11 6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 BACK FEEDING BREAKER FOR UTILITY -INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING NEC 705,12(35), 4 Interconnection Notes Scale: NTS \ j 5 Vicinity Map Scale: NTS 1, MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 5, ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6. ALL CONDUCTORS SHALL BE 6000, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7. WHEN REQUIRED,A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY, 9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING 6 General Notes Scale: NTS 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH NEC 250.134 AND 250.136(41. 3. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICRO INVERTER MANUFACTURER'S INSTRUCTIONS. 4, EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 5, THE GROUNDING CONNECTION TOAMODULESHALLBEARRANGEDSUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 6. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER NEC 250.119 7, THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 8. GROUND -FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B) AND NEC 690,41(B)(1) SPECIFICALLY. 7 irounding Notes 4i ale: NTS 8 Aerial Map Scale: NTS 1. RACKING SYSTEM & PV ARRAY WILL BEINSTALUEDACCORDING TO CODE -COMPLIANT INSTALLATION TOP CLAMPS REQUIREA DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAYISUBARRAY, ACCORDING TO RAIL MANUFACTURER'S INSTRUCTIONS. 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF -PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS, 3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 5. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL 8E STAGGERED AMONGST THE ROOF FRAMING MEMBERS, 9 Structural Notes Scale: NTS Project # Z 0 2 0 Z CC 0 U CC 1- z 0 z 0 2 1, ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. LL CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE Z REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2. CONDUCTORS SIPEDACCORDING TONEC 6903,NEC 650,7. 3. DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING f W SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE F- WIRING CLIPS. 4. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE BOR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3 - BLUE, YELLOW, ORANGE', OR OTHER CONVENTION NEUTRAL WHITE OR GREY IN 4 -WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE NEC 110.15. 10 Wiring & Conc Scale: NTS uit Notes 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH 15 OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE° (TYPICALLY THE UPPER TERMINALS). 2. DISCONNECTS TO BEXCCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE ' LOCKABLE, AND BEA VISIBLE -BREAK SWITCH 3. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS <30V AND <240VA [NEC 690.121. LOCATION OF LABEL ACCORDING TO AHJ. 4, ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.B, NEC 690.9 AND 240. 5. MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(8(. 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC -FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B, 11 Disconner'ion & OCPD Notes Scale: NTS \J ruv Amro '=.+m 0 0 0 m 0 0 w 0 J 0 w REVISION BLOCK DESCRIPTION DATE Initial Draft of Plano 915119 PROJECT: Kay, Michael 916119 ,eP'\ SHEET PV -1.1 Array Quantity Mounting Ty -� Array Tilt Azimuth rvSpacing Roof Type AR -01 18 Rush Mountk / 30.5° 180 \ 72" Asphalt Shingle" AR -02 13 Flush Mounted 30.5° 180 72° Asphalt Shingle" AR -03 2 Flush Mounted 30.5` 180 72" Asphalt Shingle" "(See PV"2.1 for Additional Information & Detai s) PV Modules Fire Clearance 0bp fictions Penetration Points Rafters f lls J O AR -03 0 a 1 PV Racking & Roof Framinc Plan Scale: 1/8" =1' " fl 1////17/41,/h Th I I II _ H--t--H f—t —'— i � I —r 1- T AR-01— 4-- 1 H I —t - AR -a2 — 18" Clearance 1 PInpp LIANC WITH NFPA 70. N2C OCT2810li CO of Tukwila UILDING DIVISION RECEIVED CITY OF TUKWILA OCJ042019 PERMIT CENTER Project# 0 u. F U W 1 0 a 0 " 0 0.000 u0Q00 st N0 smZ Q REVISION BLOCK DESCRIPTION DATE Initial Draft 0 Plans 915/19 PROJECT: Nay, Mi _916119 (-4,, SKEET PV -2.0 • AttakhmentSpacidg:6' Attachment Point rw l 30.5° Slope I I 0 (7.12) d. Max Ca r 33% Span: Span: 72" x 3%= 24" I I 2 Roof 1 Attachment Spacing Detail Scale: NTS 3 T -Bolt End Clamp Iron Ridge Support Rail Flash Foot PV Module Min. 3.5" Above Roof Roof Information Roof Material: Roof Framing: Framing Size & Spacing: Framing Span & Roof Pitch: Framing Species & Grade: Racking Information Racking I Rail Manufacture: Attachment Manufacture: Number of Attachments: Racking Weight: Module Information Modules: Module Dimensions: Module Weight & Sq.Ft.: Array Sq.Ft.: Weight Calculations Weight w/Racking & Add On Weight (Lbs.) I Attachment: Distributed Weight on Roof: Roof 1 Calculations Scale: NTS Asphalt Shingle. Rafter. 2" x 4", 24" O.C. 6'-0", 30,5° or (7:12) Pitch Douglas Fir Larch 42. IronRidge 14 Ft. Rails IronRidge FlashFoot, 72 Attachments 3.56 Lbs, I Module (33) Hyundai HIS-S370RI 77.17" x 39.29" x 1.57" 48.72 Lbs. , 21.06 Sq.Ft. 694.98 Sq.Ft. s: 1791.24 Lbs. 24,88 Lbs, I Attachment. 2.58 Lbs. I Square Foot. Flashing wfSealant Asphalt Shingle Roof (1) 5116"x4" Lag Bolt (Min. 2.5" Embedded) Roof 1 Attachment Detail , Scale: NTS Project # 0 3mo REVISION BLOCK DESCRIPTION DOTE lortial Draft of Plans 915119 PROJECT: Kay, ta{hael 916119 SHEET PV -2.1 LABEL PLACEMENT l )ELS SWITCH TO THE JUNCTION BOX 1, 2 LA DC CONDUIT 9,11 VTHE ARRAY INVERTER 3, 4, 6, 7, 8,10,19 AC DISCONNECT 1, 5, 7 PERFORMANCE METER 12 MAIN SERVICE DISCONNECT 1, 2, 7, 12, 14, 16, 17, 18 This equipment fed by multiple sources.Total rating of all overcurrent devices,excluding main supply overcurrent devices,shall not exceed ampacity of busbar. To Street For Line -Side Tap: This load center is in compliance with NEC 2017 Article 705,12(A): "The sum of the ratings of all overcurrent devices connected to power production sources shall not exceed the ratings of the service," PV Equipment Location & Fire Label Placement Table 2 Scale: NTS WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION PER NEC 690.13(B) A WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL PER NEC 110.27(C) & 1910.145(f)(7) p WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT PER NEC 690.13(B) 9, PHOTOVOLTAIC DC DISCONNECT 2 Fire La Scale: NTS )els PER NEC 690.13(8) 10. PHOTOVOLTAIC AC DISCONNECT PER NEC 690.13(B) MAXIMUM VOLTAGE: MAXIMUM CIRCUIT CURRENT: A MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC -TO -DC CONVERTER (IF INSTALLED): Inveaer Ilntegraled DC DismnneOO Enke Garage Meter 1 12, PER NEC 690.53 13. PHOTOVOLTAIC AC DISCONNECT RATED AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE 47.5A PER NEC 690.54 0 WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTORS(S) MAY RESULT IN OVERVOLTAGE OF THE EQUIPMENT PER NEC 690.31(1) WARNING: PHOTOVOLTAIC POWER SOURCE PER NEC 69D 31(G1131141 15. 0 WARNING 0 PHOTOVOLTAIC POWER SOURCE ONDePC V2VNlF.SSREUEDINEOCTLZATI7N•PVPDIIEAGACDITaAEMYoPrPN PER NEC 692.31(G)(1 ARMING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM PER NEC 690.59 & NEC 705.12(D)(3) \1OM t\AL OPERATING AC VOLTAGE QOM AL OPER GAC FREQJENCV MAXIMUM AC POWER MAXIMUM ACMIRE \T MRN UVERCURRET DEVICE RATING FOR AC MODJLE PROTECTIO\ FOR AC MODULES ONLY 14. RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PER NEC 690,56)C33) PER NEC 690.52 AWARNING SINGLE 120 -VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUITS PER NEC 710.15(C) & NEC 692.9(C( DO NOT DISCONNECT UNDER LOAD PER NEC 690,15(C) & NEC 690.33(E)(2) UTILITY METER SEPARATE FROM 0 SERVICE PANEL 16. 17. 18, 19. > To Backyard r� Project# RECEIVED CITY OF TUKWIL OCJ 04 PQ19 A CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED PER NEC 690.13(F) & NEC 705.12(8)(3.4) & NEC 69059 VAIN P OTOVOLTAIC SYSTEM DISCONNECT PER NEC 510.13(5( L WARNI VG POWER SOURCE OUTPUT CONNECTION, DO NOT RELOCATE THIS OVERCURRENT DEVICE, PER NEC 105.12(BN2)1e1 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN _ TURN RAPIOSHUTDOWN SWITCH TO THE A 'OFF' POSITION TO SHUT DOWN PV SYSTEM LA AND REDUCE SHOCK HAZARD VTHE ARRAY PER IFC 625.1 2) & NEC 690.56(C)(1((a) FORMAT: (1) WHITE LETTERING ON A RED BACKGROUND (2) MINIMUM 3(8 INCH LETTER HEIGHT (3) ALL LETTERS SHALL BE CAPITALIZED (4) ARIAL OR SIMILAR FONT, NON -BOLD MATERIAL: (1) REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL -969( AS STANDARD FOR WEATHER RATING. DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT, z 0 2 Ir 0 z 0 1— Q O z 0 z 0 2 r 11. 0 z 2 W 1— m } 0 z 1— uJ -r 0 lY 0. R 5.VIEWED F0� GO vIPLIANCE IM NFPA 70 • NEC 08T281019 City of Tukwila BUILDING DIVISION D 03 m ro 0 m 1 0 w 5- 0 N w REVISION BLOCK DESCRIPTION DATE Initial Draft of Plans 915119 PROJECT: Kap. Michael 916119 SHEET ERT DI N&S141A1ON PROKSCAeeL PV -3.0 3H 2" 511 411-- I Fire Placard Scale: NTS CRUTION POWER TO THE BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AT SHOWN 4127 S 144th St UTILITY METER UTILITY FUSED DISCONNECT SOLAR PV ARRAY WITH OPTIMIZERS ROOF MOUNTED SERVICE POINT UTILITY METERING (Panel inside GaragelMeter Outside) PV INVERTER WITH INTEGRATED DC DISCONNECT NOTE: THE PLAQUE SHALL BE METAL OR PLASTIC, WITH ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE, INCLUDE THE LOCATION OF METER, DISCONNECTS, INVERTER, THE ARRAY AND A FOOTPRINT OF THE ENTIRE BUILDING AND SITE. THE PLAQUE WILL BE ATTACHED BY POP -RIVETS, SCREWS OR OTHER APPROVED FASTENERS. Project # z 0 1 0 tl z 1 0 Q 1 z 0 z 0 F - Q 1 0 L.z W F } to 0 m m TTI 0 J w F J 0 0 REVISION BLOCK DESCRIPTION DATE Initial Draft o!Plaos 915119 PROJECT: Kay, Michael 916119 SHEET CERTIFIED PDFES CW r orfs .xk PV -3.1 CONDUIT RUN ABOVE ROOF Raceway Above Roof: Maximum Height: 3-1/2" Minimum Height: 1" Strut Strap 2" X 6" Block Rain Tight, Steel EMT Connector Junction Box — Strain Relief — Module —• DC (PV) or AC (Microlnverter) Cable Roof Framing Conduit Run Details Scale: NTS ODULE TO vODULE OLLE TO RAIL CONDUIT RUN THROUGH ATTIC Raceway Above Roof: Maximum Height: 3.1/2" Minimum Height 1" Strut Strap 2" x 6" Block Rain Tight, Steel EMT Connector Junction Box Strain Relief Module DC (PV) or AC (Microlnverter) Cable EPMD Flashing Roof Framing EMT Conduit FLEX Conduit Through Attic (18" Below Roof Material) IRDNRIDGE UFO PV MODULE FRAME IRDNRIDGE RAIL UNIVERSAL FASTENING OBJECT (UFO) THE UFO SECURELY BONDS SOLAR MODULES TO XR RAILS. IT COMES ASSEMBLED AND LUBRICATED, AND CAN FIT A WIDE RANGE OF MODULE HEIGHTS. 2 Grounding Details Scale: NTS RAIL TO THE SA CONDUIT RUN THROUGH ATTIC WITH SOLADECK SolaDeck with Flashing & Sealant Module Manufactures (AC Module) Cable Strain Relief Roof Framing 3/4" FLEX Conduit Penetrating Through Roof t12 Romex SELF TAPING SCREW NTS REMOVAL OF ONE PIECE OF EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN ANY OTHER PIECES. PV MODULE IRO RIDGE RAIL RAIL SPLICE CONDUIT RUN THROUGH TRENCH Trench Grade //< 1114" Sch 40 PVC ZGIL TO RAIL E DIFFERENT SOWS) SOLID COPPER GROUND WIRE NTS REMOVAL OF ONE PIECE OF EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN ANY OTHER PIECES. RECEIVED ITY OF TUKWILA OC1041019 PERMIT CENTER EQUIPMENT ATTACH ILSCO GBl•4DBT GROUND LUGS WISTAINLESS STEEL MACHINE SCREW (FOR EXTERIOR, WET LOCATIONS) Project # 0 z H W -n 0 0 DFD` 00 PLIANCF NTH NFPA 770 • NNEC OCT281019 CNy of Tukwila ILDING DIVISION 00 ro 2:7 °:c 7Q�0 liTnz F Q REVISION BLOCK DESCRIPTION DATE Initial Draft of Plans 915119 PROJECT: Kay, Michael_9(6119 %W'• SHEET CERTIFIED vvxsruum+ NOES I PV -4.0 Wire Tag Conductor Qty. Size & Type Neutral Qty. Size 0 Type Ground Qty., Size & Type Raceway Size & Type Raceway Location Raceway Height Above Roof Output Current 125% of Output Current Min. OCPD Wire De -Rate Calculation Dist. (Ft) Voltage Voltage Drop % Conduit Fill Wire Rating Ambient Temp # of Cond. Final Ampacity DC.1 DC.2 AC.1 AC.2 (6) #10 AWG PV Wire (6) 010 AWG THWN-2 (2) #6 AWG THWN-2 (2)#6 AWG THWN-2 (1) #6 AWG THWN-2 (1)06 AWG THWN-2 (1)#6 AWG Bare Copper (1) 010 AWG THWN-2 (1) #10 AWG THWN-2 Not Applicable 314" EMT Conduit,Above 314° EMT Conduit 314"Sch. 40Pipe Under Array Roof Exterior Wall Exterior Wall 1"To3-112" 1" To 3.112" "NIA" "NIA" 154 15A 47,54 47.54 18.84 18.8A 20A 20A 60A 60A 40A X1 X1 =40A 40A X 1 X 0.8 = 32A 75A X 1 x 1 = 75A 75A X1 X1 =754 10 Ft. 20 Ft. 5 Ft. 5 Ft 4000 400V , 2400 240V 0.09°% 0.190 0.1% 0.10 27,80 32,60 34,20 PV Module 1 (33) Hyundai H15.537081 Power at STC: 370W Power at PTC: W V-oc: 47,8V V-mp: 39.50 I-sc: 9.94 I-mp:9.4A V-oc Temp Coefficient: -0.29%1C Output (I-sc x 1.25 x 1.25):15.54 z Qa 0 00 >0 aW PV Optimizer 1 (33)SolarEdge P400(86) Max 1-sc Input: 10,14 Max V-oc Input: 60V Max Power Per String: 6000W Inverter 114070WI400V) =10.24 Inverter 1 SolarEdge TechnologiesSE11400H-US (2407) Max Output Current 47.5A Safety Rating: (47.5A x 1.25) = 59.4A Minimum OCPD: 60A Max Number of Strings: 3 Number of MPPT's:1 Maximum Input Voltage: 4800 Transformerless (YIN): Yes Operating Current: 10.24 Operating Voltage: 400V Maximum System Voltage: 4800 Short Circuit Current: 45A MSP NOTE: "AN ELECTRIC POWER PRODUCTION SOURCE SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PERMITTED IN 230.82(6). THE SUM OF THE RATINGS OF ALL OVERCURRENT DEVICES CONNECTED TO POWER PRODUCTION SOURCES SHALL NOT EXCEED THE RATING OF THE SERVICE." 000 2 PR oe 0 1 J -BOX INVERTER 1 1 2 0 2 u 10 1 Three Line Diagram Scale: NTS / a a G2 1 F a 2 UL Listed DC Disco, N ri u Performance Meter 1 Utility Performance Meter 2 Pole, Feeder Entrance: Standard KWH METER FORM 25,100416000 PER NEC 705.12 Main Panel Interconnection Information Bus Bar 1 Rating: 200A Main Breaker 1 Rat ng: 2004 PV Back Feed (Actual Load): NIA PV OCPD: NIA Interconnection Calculation:120°0 Rule Not Applicable PM AC DISCO.1 AC Disconnect #1 60A Utility Fused AC Disconnect #1, 2 Pole, 01604 Fuses, 240V, Lockable, Visible, Rated NEMA 3R Ambient Temperature Information Extreme Min Temp: -60 Ambient Temp: 290 Ambient Temp. Adjustments 0" to 7I8" Above Roof: 620 Voltage Drop Information DC Voltage Drop: 0.280 AC Voltage Drop: 0.2% Total System Voltage Drop: 0.48% 1 Phase 160 Hz. (E) 200A Rated MSP —N Line -Side Tap r Main Breaker y (E) 202A f Ins Main Service Panel 1 Existing 200A MSP, Top -Fed 10, 3W,1201240V Utility: Seattle City Light Interconnection: Line -Side Tap Main Breaker pe;Rated:No — Existing Wires #6 AWG AUXILIARY GROUNDING — ELECTRODE CONDUCTOR ATTACHING TO EXISTING GROUNDING ELECTRODE round Rod (E)GROUNDING ELECTRODE 0/ — Tota 210 Lf Underground L24— Se,vu Utilifu Meter Project # 0 b 2 f 0 LL z 0 Q Z co 0 u 0 N z 0 I— z O 0 z 2 W 61 1)0 0 4 0 0 .000 ro ico'D0 X0000 �3md 0 N08 >0.0 Yr`s�Z e 74,0. c REVISION BLOCK DESCRIPTION DATE Initial Drah of Plans 915119 PROJECT: Kay„ 0 heel 916119 IICW M14 PRpiFSSGILL Swan PV -4.1 (1 HYUNDAI SOLAR MODULE RI SERIES Mon11•CrystaHine)(go HiS•S3WRI HiS•S366RI HiS•S310RI HiS•S315RI 72 � HYUNDAI CELL For Coln & More Powe Hyundai Cel. UI Oy Ap cal ons Generation In Low light PERC Technology PERE technology provides uNra•high eifidemry with better performance In low Irradiation, Matdmkes installation capacity In limited space, Reliable Warranty rmwrau Global brand with powerful financial strength provide reliable 30•year warranty, Hyundai's Warranty Provisions 2-YearProduct Warrant/ hip (1)30 -Hear Performance Warranty Initial year: 97.6% linear warranty after second year: with 0.6%p annual degradation, 802%b guaranteed uP to 30 years Certification DUS � E r®w una Dm Data Sheets Scale: NTS Ga NV dao V Anti•UDIPID Both LIDILIght Induced Degradation) and PID(Potenlal Induced Degradation) are strictly eliminated to ensure higher actual yield during lifetime. Corrosion Resistant Various tests under harsh environmental conditions such as ammonia and sag -mist passed, r1 t t t Mechanist Strength Tempered glass and reinforced frame design withstand rigorous weather conditions such as heavy snow and strong wind, 00 UL I VDE Test Labs Hyundai's R&D center is an acoedded test laboratory of both UL and VDE About Hyundai Solar EstabfAhed In 1972, Hyundai Heavy Industries Gird Is one of the most trusted names In the heavy industries sector with 48,007 employees and more Ian 40 Bea USD in annual sales (2215). As a global leader and Innovator, Hyundai Healy Industries is committed to budding a future grownh ergine by developing and Investing heavily in the fled of renewable energy, Started as a core business daidon of HITT, Hyundai War (Hyundai Heavy Industr%s Green Energy) now stands as an irdependentcompany and an afiliale of HHI as from December 1016. We have Wong pride in providing high-quality th' products to more than 3,000 custoniers worldwide. HYUNDAI GREEN ENERGY Puna g ratell/M1 Electrkal Characteristics Nominal °ulpal71 rti Open Circuit Voltage,Vuc1 Shoe Circuit Currant Voltage al Emu Nnppl Current al Peat pPt11 Module Efficiency Celllype I Maximum System Voltage Temperature content al Nat Tem eratur¢coelfcienlalSot Temacrtturc coefficient al 1st Mechanical Characteristics O Project # MaooiCrys0liioe Module jNiSS_Nl ahi 360 47A 410 99 9,9 9,9 100 &11.1 12 —ass 17 92 9.3 911 9.4 1&4 117 199 192 6',m0.ov Pan -029 01139 1,962 mm (77,11414 a 40 mm (1.5flH) 72callsInsalet6z12mab14lN Neal Peas) 1 mm' i12AN able with pat* watwpraol annastors, ECceti9ad 81IthtedandUL4703arUlkdl,length1.2mP1.1j KliPea9ropmd,ECcerded AIL I 3gpassdodosthpeuwdpowerdarasebyAMA dada Ram ; N &mJledon paledgleno, 32 mn (0.126) EncapsolantiEVAI6adtSheet:Weal4rproolflm DDM Mmdb¢d aluminum a1 by nos 65&3 Module Diagram wm.mo Dmau nsrau esorasoe seoreaae INUMNISTUWDINAdtlItrtMAIMANAIDONtaIIMM2, Installation Safety Guide • Only qualified personrel should instal or perform maintenance. Be aware of dangerous high IX voltage, Do not damage or scratch the rear surface of the module Dont handle or install modules when they are wet NmthmlOperWg 46'8±2 OpwatingTmgamen .10-95'9 NadmmnSydanHo q vow cehAo9m 015(9) MadmwnRarwaeCumd 744( 1 I V Curves Ong RECEIVED TY OF TUKI OCT 042019 -wam.ma+ VI IT CENTER AHYUNDAI GREEN ENERGY 90050ate:00 019 Sales &Marketing 55iBu ang-r4EuMangyu,SeongnamsiGyeoglas,13591,Korea I rilomhhiyeenr Te: Pena: r1-211.3201704Ueda :+81.3-6717.7415 I Faa:+82-31-93054 67 6uaPa: x49.89-11011.2023, Auslrala:'11.21238-7M GO PUANCEVVI NFPA 70. 0C 0CT2B 1019 City of Tukwila 9UHLDING DIVISION A m m F J 0 00 00 NHm0 0.00m0 ug—,00 inti REVISION BLOCK DESCRIPTION DATE Aalal Craft of Plans 915119 PROJECT:' day, Michael 916119 Aa,, ERTIFIED DATA S-EET Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800F -US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US sapid jrpw,,e 0 ) 0 0 0 ■%: 0000 0 0 0 0 0000 1 0 0 '/ \ r 11 Optimized installation with HD -Wave technology 1 Specifically designed to work with 1 Extremely small power optimizers 1 Record-breaking efficiency 1 Built-in module -level monitoring 1 fixed voltage inverter for longer strings 1 Outdoor and indoor installation 1 Integrated arc fault protection and rapid shutdown for 1 Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 1 UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com Inverter Data Sheets Scale: NTS Class 0,5 (0,5% accuracy) sola m / Sin le Phase Inverter wit HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000--US / SE11400H-US SE3000H-US SE3800H-US SESOOOH-US SE6000H-US SE7600H-US SE1000OH-US SE11400N-US OUTPUT Pined AC Poxn output 3000 3915@2405 330002 5000 6M@240V S000 0 2082 1645 5000 11400 0 240V 10000 0 2085' VA Marn*umACPsrmOai 3000 ��@2405 3300@21.92 5'000 60N@2455 505@208V 7 MN 11400@2405 10000020814 VA AC Ovipin voltage Min. -Nom. -Mad 2111.240-2641 V V V d 1 1 t Vac AC Output Voltage Min;NomnMax. 093.208 229) Nominal DC input Voltage 345 400 vdc Maximum Ing, Current@240455 vol AC Frzquemcp Mornhe8 59.3-60-4555 Ho reanmmcon6wasCutpt Cwm1 @240v 125 16 n 25 32 42 . 47 y • A Maximum Con6nuanatpul Ca'Anl 03195 16 - 24 45 1423 A GFDIThreshold A Nig Monilor¢tg, Isandog Praectul Country Cosf ss bN Thresholds Ya Sane -Rout IsoiaomDe;eaon INPUT ManimrmDCRawer @2409 4650 5900 7750 9345 11840 15500 17550., W Medlin DCPower 0208V - 5100 Weighty/Rh Saleg 5nich 7750 - - 75504 14 Transforme,less,Ungrounded Nang Yes OoerahrgTemperature Range Maintop Ingo Voltage 'S It 480 NEMA 44 (Ireatenvith Safety S1Ach) 335 Nominal DC input Voltage 345 400 vdc Maximum Ing, Current@240455 85 10.5 135 165 20 27 32.5 Ad( 4455<5<57<9/7(52225<5 9 - 133 27 Ado Max. Input Shin Cirmll Comenl 45 Ado Renerse-fdarrty Protection Yes Sane -Rout IsoiaomDe;eaon 5014<SenH5n'ry Ma53mumInverter E6ciieny 99 93,2 % CECWegh(edEfromy 99 99@24Gv 98.50208V % Nighrdm Parer Consumpdm 525 el ADDITIONAL FEATURES Supported Commun'aalm Imsrtac4s Revenue Grade Data, ANSI Cato Rapid Shmcam - NEC 2014 and 201764512 STANDARD COMPLIANCE Safety God Connection Standards 85495, Ethernet Zig9re (op tbnal6 Celli (opdernap 0455155 Autom114 Rapid Shutdown upon AC Grid 00sconr 4 011741, 011741 SA, 0115999, C5AC222, Canadian MCI according to 111 4-17 5EE1547, Rule 21,8u1e W Pei Emssima FCC Pan 15 Class 8 INSTALLATION SPECIFICATIONS ACOuqutConduit SaelAwG Range 3/4'minmss/14.6 AWG 3/4'm5nIlium /14.4 AWG CC lnpnCordial Sloe IMo Sidings l 02 Rmge 374"minimum/I-2virgs/14-6AWG 3/4'minimum/1.325957-6 81'/G Dimensions vnthSafttySvmd1 (034453/ 17.7<R.6x68 /4S0<370x174 213d46e7.3/540x370P165 in/ mm Weighty/Rh Saleg 5nich 22110 251/7.4 26.2/119 38.9/17.6 I4/43 9urse 525 ( 550 199 Nang Na5ralCnmtlmn OoerahrgTemperature Range -40 to<140/.25lo, (FI.40'Cop55n)< 'S It Protection Ralirg NEMA 44 (Ireatenvith Safety S1Ach) ^ 45 other 595,i selirOasermun Swuf4e sorc P A hiyFer caret sme may te used et here al Grp u mpA Nrml m Ire rales altd eReen,egrdde hemrPM S6v9s{SP NC2 nr« enEnsninn reiernatrellen'«aiare6gemNssneraCdlena-eprahM omrarraµi -41))1K sic)) P,M: SEnoa)KUSDAN9u4 5Wegtinnaloginlrc POsmt:LW: IASarl6LebggONIZED SWAM( rem'.iba nIrredutlrmW10535+3016** k41 otlbodmptmimod lin in tMenaeoul*rapt&UmnmYe IYNtAnLN'IA SAjnim elwp h4l mon RoHS Project # 0 0 z 0 U 1 z 0 U 0 CF Ct 0 tL zz W F to )- a X REVISION BLOCK DESCRIPTION DATE Initial Draftof Plans 915119 PROJECT: Kay, Michael_916119 Wen CERTIFIED DATA S-EET Power Optimizer For North America P320/P340/P370 /P400 /P405/P505 PV power optimization at the module -level 1 Specifically designed to work with SolarEdge 1 fast installation with a single bolt inverters 0 1 Next generation maintenance with module - 1 Up to 25% more energy level monitoring 1 Superior efficiency (99.5%) 1 Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading 1 Flexible system design for maximum space utilization solaredge.com Optimizer Data Sheets Scale: NTS 1 Meets NEC requirements for arc fault protection (MCI) and Photovoltaic Rapid Shutdown System IPVRSS) 1 Module -level voltage shutdown for installer and firefighter safety 1 Power Optimizer For North America P320/P340/P370/P400/P405/P505 Optimizer model (typical module compatibility) P340 P310 P400 P505 P320 (for higher. P40S (forhigh• forl?&46 (for higher (f or 60 -cell power Iforthin flm modules) Pnodules, Goand72-cell ell modules) current modules) modules) modules) modules) INPUT Rated leg DC be 320 1 340 370 N6 405 3123 W 4bsdum Maximum lopul Voltage *at 48 19116 453/ 5.1x63x23 60 60 125, 83m /33 MPPT Ope26rg Range 8-48 InpaComic( 8-W 8.80 2.S -10S 2363 %e Maxrnum Short Grtuh(rent PRI Odgratwaslelghl 11 q.1 14 Adc MaamumXITV Current 09eaurg T mperdure Ra rg¢ 1375 1233 173 Ada McKmum Efficiency Relate Humidity 495 % Weighted Efficiency 99.8 98.6 % Ovewttige Campo/ OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TOOPERATING SOIAREDGE INVERTER) Maamum O,nput foment Maine a pn Voltage OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOIAREDGE INVERTER OFF) SafMr4A vtge Per Powe °Omar STANDARD COMPLIANCE 412c Sdc 85 1E 01 EMC Safely BONS fCC Pard/ Class d IEC61000•6-2IEC67000-6-3 IEC62159-1(dass II safety/ U11141 INSTALLATION SPECIFICATIONS Maumum /Mond S9eem sdmge 1000 Compatible im inters A6 Sdar3dge Singe Phase NM Three Phaseimermvs 129 x163x2151S.1r6x1.1 591/361355/ 1Dimensicros:ILO) 3.1x6x1.3 '19x1/9449./1 3.146.3119 19116 453/ 5.1x63x23 m1M Weightprddig cahksi 630/1,4 73011.1 873/1.9 1064/23 gr/to InpaComic( MC40 ()quiOff reType/CmrmCtdr Double 1/334md;MC4 Odgratwaslelghl 0.95/3.0 I 12/3.9 m/ ft Nut Wirelergrh 0.16/032 mIft 09eaurg T mperdure Ra rg¢ -40-65/-40-+185 'C /'E Praecdmfialing 433/NEMA6P Relate Humidity 0.100 % tWtcdSRpnedae*A,, MMofuedupm apaetdeattdand ,,NEC Anrep es whptatge to rm mat tan IN ro okr comma ;Am p'eme maz Sdaddge P5 System Design Using aSolarEdge Inverter i' Minimum S6irg le RomrOpamuell 4403 / 9505 Single Phase Singlephase Three Phase 2085 Three Phase480V HD -Wave Maximum Poorm463/i44 Project# z 0 4 1 0 z 1 0 1 4 1 z 0 U z 0 cc 0 z iU f— ln 0 11 z U RECEIVED W TUKI�'ILAO its Fa de* Eng leartdoreIe m: tpemtwlatdgemrytirrrdela3nfey Nslugnapdf he Nxab le mmhPNSy7SC4w'4aPMP3e6'Vi1 R4O meeOng 04mhgWm me 3aoptimal doesztmMNEC *Mow atrrrmmsAMYamproxgot th 3M rtgumnmt afaSE11.411502Ml4nalma Nal 6.2),N per ming wtrn311-ircNwmtrenMmu4mensp ergspa atb H4321115)andrdei me mmlmma pare gene bow fie stn q b up m 1AAv era SE3CCME333116,1SEkEWSAEttO4uS:nif rehired*Ira;to 5,03061:km g wfen3 sags art rcnnene Oienep¢mp per for SEEMYSEMUSI aNden the maim pxerddaxxeb eMm the ON3 aWm2a0Bu' C bWVectro u4NOm* SfUEA Wife to CPIED BISOAUD3nodrtrta gond indroM dSolaWdnbjnh 01 1019 O PLIANCEFWITH NFPA TO • NEC OCT 28 CNy of Tukwila UIIDING DIVISION e�E REVISION BLOCK PERMIT CENTERDESCRIPTION DATE Initial Draft of Plans 9/5/19 Alone Etat imunIte0 n Mont A 4b'rngal4e wen* 1110,11% kW*CAnptIrroaC (E ROIL$ PROJECT: Kay, Mithae1916119 DATA SHEET Attaciment 1 Attaciment Data Sheets Scale: NTS Project # 0 1 0 LL rZ 1 0 o Q 000 Hm17 m4,p40 uImQID0 H3Lnma mwo �NyTz N# ID F Q REVISION BLOCK DESCRIPTION DATE Initial Draft of Plana 915/19 PROJECT: Kay, Michael 916/19 ICERJJFJEDi I"e1AUM inrFOM DATA SHEET ixt18i� '!: Installation Overview Tools Required: tape measure, chalk line, stud finder, roofing bar, caulking gun with an approved sealant, drill with 114" bit and 112" socket. Df/\ IRONRIDGE Rapid & Secure Solar Attachments IronRidge FlashFootTM is an all -in -one solar mounting product for composition shingle roofs that eliminates the need for separate standoffs, flashings, and L•feet• FlashFoot incorporates a number of structural and waterproofing features to securely attach IronRidge� Rails to roof structures, while also protecting against water intrusion and weather damage. FlashFootTM rhNlir� jjjj 1 ,' ? T Rafter r� �,� �� v k d p' sr, w d o u F eeerses ist verse fit* r ,,' Load A solid increases strength ol the 0 a n CP 40 Distribution Plate metal Ole below the Hoot765 the FlashFom's structural and prevents any deformation flashing during installation. at IRCaty mc, •` Dual Mechanical Seal 0OecoreofIteFlasloot,apre-installed rubber bushing fors a dual mechanical seal, wgh its exterior compressed against the cavity of the Hoot and its interior lightly wrapping around the shah of the lag bolt = ° t' e° •t�y '¢ Tilt r , ',' gq 3? " Water Shedding Design A wide flashing layer combined wtlh an elevated sealingplatlormmaximizesth�e FlashPool's water shedding ability, Locate rafters and snap vertical and horizontal lines Slide flashing, between 1st and 2nd course, so the to mark locations of flashings. Drill 114" pilot holes, top is at least 314" above the edge of the 3rd course then backfill with an approved sealant and the bottom is above the edge of the 1st course. "" r- 11 E � Line up pilot hole with flashing hole and insert lag The FlashFoot is now installed and ready for bolt through bonded washer, L•Foot, and flashing. IronRidge Rails. With provided Ldoot fasteners pre. Tighten lag bolt until fully seated. loaded into rails, drop rails into open L•foot slots. Testing & Certification FlashFoot is certified for compliance with the International Building Codes (IBC) & International Residential Codes (IRC) by IAPMO•ES. Mechanical testing conformed to the standard for Testing and Analysis of Joist Hangers and Miscellaneous Connectors (EC002-2011), and rain testing conformed to the Underwriters Laboratory Standard for Gas Vents (UL 441.96 Section 25). 00661a5 N, Lerch 32 0° d" E"' E044 Sm. 1mgemusmenrsa105011nyveo as zas 1150,77 He/67i7{10 .45 7135 &Am ane ss sa sp�w'cvan w 015 Spno,,Rie•Ar1E d 1n550566 6 7 50025 of 10800E12 .Sa 7513para L,a•...5"tuyesmoo „AiivAMoAsroomn,..emrmimw l'�gb...q".a 'lir 6 ;uA.a'h'A �", lnitk. 07`1‘1'n •' 'z1'6 //ilk Attaciment 1 Attaciment Data Sheets Scale: NTS Project # 0 1 0 LL rZ 1 0 o Q 000 Hm17 m4,p40 uImQID0 H3Lnma mwo �NyTz N# ID F Q REVISION BLOCK DESCRIPTION DATE Initial Draft of Plana 915/19 PROJECT: Kay, Michael 916/19 ICERJJFJEDi I"e1AUM inrFOM DATA SHEET IRONRIDGE Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame, XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail Family Force•Stabilizing Curve Sloped roofs generate both vedice and later! forces on mounting rails which can cause them M bend and twist. The curved shape of XR Rails is specially desgned to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are IronRidge offers compatible with a range of tilt leg �r^n` FlashFootand options for hat other Oohed roof roof mounting ahedrments. applications. 1 Rail Data Sheets Scale: NTS Corrosion -Resistant Materials All XR Rails are made of marine -grade aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more allractive appearance. Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with Ight or no snow. It achieves 6 fool spans, while remaining light and economical • 6'spanningcapability • Moderate load capability • Clear & black anodized finish • Internal splices available Rail Selection XR100 XR100 is the ultimate residential mounting rail. 11 supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8'spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR1000 001000 is a heavyweight among solar mounting rails. Its bui0 to handle extreme dimates and spans 12 feet or more for commercial applications. • 12' spanning capability • Extreme load capability • Clear anodized finish • Internal splices availablo The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7.10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load Snow (PSF) Wind (MPH) None 100 120 Rail Span 140 XR10 160 100 120 10.20 1- 140 40 60.90 160 160 100 30 160 100 160 50-70 160 5 4 XR100 8 10' 061000 RECEIVED —CA PERMIT CENTER 20141 NO, Irx. All fights remelt 0 I w vioN219e.com or ca111.800-227.95T2 for more information. wrslon 1.12 Project # z 0 4 CC 0 u. z O 0 F Q O z 0 Z 0 Q O 0 u. z W } U1 0 U. z W 0 O a ' VI ED FO OOMPLIANC WITH NFPA 770 NEC CT28 19 City of Tukwila EUILDING DIVISION REVISION BLOCK DESCRIPTION DATE nitialDraft ofPlans 911119 ii�- PROJECT: Kay,Michael916119 VFECEP CERTIFIED PIMAD SS DATA SHEET PERMIT WORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0824 PROJECT NAME: KAY RESIDENCE SITE ADDRESS: 4727 S 144 ST X Original Plan Submittal DATE: 10/03/19 Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: t Division Public Works Fire Prevention Structural ri Planning Division Permit Coordinator • PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/08/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (ie: Zoning Issues (corrections entered in Reviews) DUE DATE: 11/05/19 ....••••••••• Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 0 Some online services are currently unavailable. See a list of service outages. rhtws://lnima,poviagency/system-stalusl 116 Labor 8, industries (httpviliiimaxj,v1 Contractors SOLTERRA GLOBAL LLC Owner or tradesperson Principals Heather, Brian, PARTNER/MEMBER CARPENTER, AIMEE MARIE, PARTNER/MEMBER COLUCCIO, MARC, PARTNER/MEMBER Carpenter, Aimee, AGENT Heather, Brian, AGENT (End: 07/11/2019) Doing business as SOLTERRA GLOBAL LLC WA UBI No. 604 041 594 2910 1st Ave S #201 SEATTLE, WA 98134 206-462-1103 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active Meets current requirements. License specialties GENERAL License no. SOLTEGL838BS Effective — expiration 01/10/2017— 01/10/2021 min!§trAt9t: Fekete, C Timothy Active Meets current requirements. License type License no. Electrical Administrator FEKETCT882JS Bond International Fidelity Ins Co Bond account no. SAFSU0712189 Received by L&I 01/10/2017 Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. $4,000,00 Effective date 12/21/2016 Expiration date Until Canceled Certifications & Endorsements OMWBE Certifications No active certifications exist for this business,