Loading...
HomeMy WebLinkAboutPermit EL19-0841 - SHASTA BEVERAGE - ELECTRICAL AND CONNECTIONS TO REFRIGERATION COMPRESSORS, GAS LEAK DETECTION AND OUTSIDE CONDENSORSHASTA BEVERAGE 1227 ANDOVER PARK E EL19-0841 Parcel No: Address: City oPukwila � Department o° Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206'431'3670 Inspection Request Line: 206-438'9350 Web site: http://www.TukwilaWA.gov Fire Inspection Request Line: 206-575-4407, Option 2 ELECTRICAL PERMIT 3523049072 Permit Number: EL19-0841 1227 ANDOVER PARK E Project Name: SHASTA BEVERAGE Issue Date: 9/3/2030 Permit Expires On: 3/2/2021 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: NATIONAL BEVERAGE CORP 8100SVV10TH6TSTE4000' PLANTATION, WA, 33324 DAVID KEHLE 1916BONAJRDRSVV'SEATTLE, WA, 98116 DIAMOND BAR ELECTRIC INC l3961CENTRAL AVE ' CHINO, CA, 91710-5556 AEC3532 Phone: (206) 433-8997 Phone: (909) 860-6590 Expiration Date: 4/3/2021 DESCRIPTION OF WORK: INSTALL NEW ELECTRICAL AND LOW VOLTAGE CONNECTIONS TO REFRIGERATION COMPRESSORS, GAS LEAK DETECTION AND OUTSIDE CONDENSOR. Valuation of single family: $0.00 Valuation of mf/comrn: $2I000.00 Type of Work: TENANT IMP Fees Collected: $66927 Electrical Service Provided by: Ptiget Sound Energy Water District: Tukwila Sewer District: Tukwila Current Codes adopted by the City of Tukwila: International Fire Code Edition: International Buliding Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: 2015 20152015 2015 2015 2015 National Electrical Code: WACities Electrical Code: WAC 296-46B: WA State Energy Code:2015 2017 2017 2017 Permit Center Authorized Signature: Date: C.) 1 hearby certify tha1 have read and examined this permit and know the same to be true and correct. All provisions of law and occlinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or Iocal laws regulating construction or the performance of work. 1 am authorized to sign and obtain this development permit artd agree to the conditions attached to this permit. Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical worpermit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, anci requirementsfor electrical installations, Chapter 296-469 WAC and the Washngton Cities Electrical Code. 5: When any portion ofthe electrical installation is to be hidden from view by permanent placement of paris of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be corrstrued to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (20G)#38'835¢ Fire Permit Inspection Line: (20G)575-44O7,ext 2 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE CITY OF TUKWILA Community Development Department Permit Center 6300 Southeenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Z2&1 off Project No. Date Application Accepted: /0/1 5 b Date Application Expires: 04a15/a° (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 1 Tenant Name: 00462— fteihtle Ito King Co Assessor's Tax No.ite Suite Number: CiegbiToiJ 4 Co4fneix,e-a—. PROPERTY OWNER Name: Nook oeveizobcx itic. Address:1221 toczoleizzaz. ,ac.A... City:Tuctulac State ZipCibkft CONTACT PERSON — person receiving all project communication Name.-daltv to5s44Ae Address: tet Lu ot,i4ittrz. pm Nak,) City: oemne, Stat : ZiPq2pV V LC Phoneitm. 433 Vag.lAkp- &Nil Email: 4164311.e e jaiewearm, com, Floor: New Tenant: J Yes 54,.No ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No., Valuation of Project (contractor's bid price): $ LJ Scope of Work (please provide detailed information): tWitZgA• N5N acretza4, bev tam V� LTIAig GAKEEXtax., Vern(4.1517/317c4-) C116/ki Wte'ingoi) .AV Stoptve Co4easeg_. Will service be altered? EJ Yes rg, No Adding more than 50 amps? ED Yes 24 No Type of Use: Type of work: 0 New E] Addition 0 Service Change D Remodel X, Tenant Improvement 0 Low Voltage [1] Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: Puget Sound Energy D Seattle City Light Wi Permit Cent erlApplications-liandaucs1Perrnit ApplicationstPDF's \Electrical Permit Application Revised 1-17-1 9.doca Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE O New single family dwellings $180.00 (including an attached garage) E-.1 Garages, pools, spas and outbuildings ..... ,$120.00 ea 0 Low voltage systems (alarm) $60,00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES O Service change or alteration $120 00 (no added/altered circuits) O Service change with added/altered circuits $100_00 number of added circuits $10.00 ea O Circuits added/altered without service change $60.00 (up to 5 circuits) O Circuits added/altered without service change $60,00 (6 or more circuits) $10.00 ea O Meter/mast repair $80.00 O Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES EJ Temporary service (residential) $60.00 EJ Temporary service (generator) ............ $90.00 O Manufactured/mobile home service $100_00 (excluding garage or outbuilding) • Carnivals .... ............. ........ ...... $100,00 Number ofconcessions ....... ...... $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% 1ECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TI -IE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THJS PERMIT. BUILDING OWNER 0 CTRJCAL CONTRACTOR: Signature: Date: lei 141 Print Nam11419 )6eikke Mailing Address: kcitU ftc4i,ta. Ve. 42\Y Day Telephone: tag - q - City WAPerrnii Cenier1Applicalions-Handouts \ Permit Applications1PDPsElecirical Permit Application Revised I-17-19.docx VI) State eibtl Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PsAiI3D1.81 '.., v., PermitTRAK o's „u„,,,,r„ ,, ,„1„„„ ,,,„„,,,,,,p,,,,,,II„,,,,,7„,,,i ' ;„1, ,,,, ,., , , , !,. ,,, , 31.81 EL19-0841 Address: 1227 ANDOVER PARK Pn• 49072 Credit Card Fee $3.84 Credit Card Fee R000.369,908.00,00 0.00 $3.84 ELECTRICAL $127.97 PLAN CHECK FEE R000.345.832.00.00 0.00 $127.97 TOTAL FEES PAID BY RECEIPT: R18821 $131,81 Date Paid: Tuesday, October 15, 2019 Paid By: WILLIAM N JOHNSON Pay Method: CREDIT CARD 01629P Printed: Tuesday, October 15, 2019 10:17 AM 1 of 1 CRWS Y5 TEM5 CO TUKWILA ETRAKIT 620e SOUTHCENTER BLVD TUKWILA, WA 98188 206-433 -1870 CITY OF TUKWILA 0017340000802374464500 Date: I8/15/2819 10:17:20 AM MASTERCARDCREDIT CARD SALE CARD NUMBER: **********7168 K ToAN AMOUNT: $131.81 APPROVAL CD: 01679P RECORD #: 000 CLERK ID: Laurie x {CARDHOLDER'S SIGNATURE} T AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Payment Processing Complete Your payment was received and processed successfully. Permit Number: EL19-0841 Permit Type: ELECTRICAL Address: Permit Date: Receipt Number: 358775108 Fees Paid Fee Description TECHNOLOGY FEE ELECTRICAL Total 1227 ANDOVER PARK E 10/15/2019 + Amount Showing 1 to 3 of 3 entries $2559 $511.87 $537.46 1/1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PIIRMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project. Type of Inspection_ Address: . 'Date Called: � i Special Instruction : 4 m Date Wanted: a.m. p.m. `kequester: Phone No: Approved per applicable codes. Corrections required prior to ap aroval. COMMENTS Inspector: -Date: RE1NSPECTI N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. )City of Tukwila Department of Community Development November 19, 2019 DAVID KEHLE 1916 BONAIR DR SW SEATTLE, WA 98116 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL I9-0841 SHASTA BEVERAGE - 1227 ANDOVER PARK E Dear DAVID KEHLE, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. • CORRECTIONS/ #1 1) 4th PAGE (NO SHEET NUMBERS FOR REFERENCE) PROVIDE WIRE AND OCPD SIZES FROM MOTOR STARTER PANEL (RFMCP) TO HEATERS AND MOTORS. 2) PROVIDE AMPERAGE AND WIRE SIZES TO CN4101. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. EL19-0841 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 david kehle arc !tact October 14, 2019 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: Mr. Jerry Hight RE: Shasta Beverage Inc, 1227 Andover Park E Tukwila, WA 98118 Tenant Improvement Electrical Refrigeration, Gas Detection System and Condenser Dear Mr. Hight, As the Design Professional In Responsible Charge, I have reviewed the attached permit submittal, drawings for the new electrical and gas detection system for the Glycol/ Ammonia room and outside condenser. They are not stamped by and engineer but show what is being done. I believe these are adequate for permit submission and initial review. Please accept for permit review. Sincere ly, David Kehle 1916 Bonair Drive S.W. Seattle, WA 98116 RECEIVED CITY OF TUKWILA OCT 15 2019 PERMIT CENTER ELM MN 1 (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch.com aavid kehle architect June 29, 2020 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn; Mr. Jim Benner RE: Shasta Beverage EU 9-0841 Glycol Room 1227 Andover Park E Dear Jim, RECEVED CITY I OF TUKVVILA JUL 1 4 2020 PERMIT CENTER This is in response to your correction letter #1 dated November 19,2019 where there were two comments on the KHS drawings. Item 1 is now corrected and shown with sizes and voltages from the motor starter panel and item 2 was wire sizes to CN4101. The changes are clouded on the two sheets with a revision date of 6/25/20. I trust this will suffice to answer your comments. If you have any other concerns or comments, please let me know. Si David Kehle Encl. Revision Submittal form Revised two sheets clouded 1916 Bonair Drive S.W. Seattle, WA 98116 (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch.com davd kehle architect March 24, 2020 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: Mr. Jerry Hight Requesl. for Permit Application Extension # 1 Current Expiration Date: Extension '1-ecitiest: 1)(1 Approved For f days 12-020 Den ICC, (providc RE: Shasta Beverage Inc, 1227 Andover Park E Tukwila, WA 98118 Tenant Improvement Permit Extension EL19-0841 Glycol Low Voltage Dear Mr. Hight, Signature/Initials I am in receipt of letters from Bill Rambo, permit tech, that the above permit will expire on 4-15-20 and that there are outstanding comments. I am asking for an extension to this permit for the following reasons: 1. There has been a hold up of work at the plant due to the pandemic issues going on to keep the plant staff safe. 2. There is a delay in the response from the engineers due to the pandemic. They are working on the responses to the correction letter. These issues are being resolved but construction will not be completed nor inspections called for before the expiration date. I believe these are adequate to allow for the extension of the permits. Sincerely, David Kehle 1916 Bonair Drive S.W. Seattle, WA 98116 RECEIVED CITY OF TUKWILA MAR 25 2020 PERMIT CENTER (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch.com 3/5/2020 City of Tukwila Department of Community Development DAVID KEHLE 1916 BONAIR DR SW SEATTLE, WA 98116 RE: Permit Application No. EL19-0841 SHASTA BEVERAGE 1227 ANDOVER PARK E Dear DAVID KEHLE, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 10/15/2019, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of COMMENTS OUT and is due to expire on 4/15/2020. If you still plan to pursue your project, you are hereby advised to do one of the following: I) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL19-0841 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0841 PROJECT NAME: SHASTA BEVERAGE SITE ADDRESS: 1227 ANDOVER PARK E DATE: 7/14/2020 Original Plan Submittal X_ Response to Correction Letter # _1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: <S?, 1-)C11-0,0 Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator 1 PRELIMINARY REVIEW: Not Applicable El (no approval/review required) REVIEWER'S INITIALS: DATE: 7/14/20 Structural Review Required DATE: Lil APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) DUE DATE 9/10/20 Approved with Conditions ra— Fire Fees Apply El Denied (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPP PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0841 DATE: 10/15/2019 PROJECT NAME: SHASTA BEVERAGE SITE ADDRESS: 1227 ANDOVER PARK E X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 0-0 1k \1 ilding Division Public Works Fire Prevention Structural r Planning Division Permit Coordinator LJ 1 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/15/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews Notation: DUE DATE: 11/12/2019 Approved with Conditions E Denied (ie: Zoning Issues) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg g Fire 0 Ping LJ PW D Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA,gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date:aelox Plan Check/Permit Number: EL19-0841 E] Response to Incomplete Letter # • Response to Correction Letter # 1 [l] Revision # after Permit is Issued ▪ Revision requested by a City Building Inspector or Plans Examiner ▪ Deferred Submittal # Project Name: Shasta Beverages, Inc ..d27 Andover Park E Project Address: k‘f7 4EVkA, Contact Person: Summary pf Revision: 1.1%-rakka0 RECEIVED CITY OF TUKVVILA JUL 14 ?MI PERMIT CENTER Phone Number:IC& 34 vtu 4315e5WM*totz 47110-02 giet. lex Iwripep 2) tvtgc v, tAarop -0 61-1 41o1 Sheet Number(s): "lei3V) CetWIA9 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: OAA -L' Entered in TRAKiT on 7 1 q- CAUsers \bill -r \Desktop \Revision Submittal Form.doc 9/3/2020 Diamond Bar Electric Inc L&I regional offices are closed to public visits until further notice. Offices can still help you by phone from 8 a.m. to 5 p.m. weekdays (except state holidays). Use the phone number for your closest regional office (logps://lnima goviagengy/contact/Itoffice-locations), or you can call the Office of Information and Assistance at 360-902-5800. w.hington Stale Df Labor & Industnes(mpswinimasggy). Diamond Bar Electric Inc Owner or tradesperson Principals Bogy, Matthew B, PRESIDENT Bogy, Therese L, VICE PRESIDENT CT Corporation System, AGENT Doing business as Diamond Bar Electric Inc WA UBI No. 604 355 870 13961 Central Ave CHINO, CA 91710 909-860-6590 Business type Corporation Governing persons MATTHEW B BOGY THERESE L BOGY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active Meets current requirements. License specialties GENERAL License no. DIAMOBE812DH Effective — expiration 04/02/2019— 04/02/2021 Designated administrator Active ST CLAIR, DENNIS RYAN Meets current requirements. License type License no. Electrical Administrator STCLADR994PF Bond Developers Surety & Indem Co $4,000.00 Bond account no. 658031C Received by L&I 04/02/2019 Savings No savings accounts during the previous 6 year period. License Violations No license viOlations during the previous 6 year period. Effective date 03/01/2019 Expiration date Until Canceled Certifications & Endorsements OMWBE Certifications https://secure.lni.wa.gov/verify/Detail.aspx?UB1=6043558708,LIC=DIAMOBE812DH&SAW= 1/2 0 (U Nimal • lU 0 0 m 1 a 0, fU .. 0 0 I 11 A. B. C. D. E. F. G. H. ntake Vent to Room 14 t 15 I 16 1 17 1 18 I 19 I 110 111 I 112 113 I 114 115 116 I 117 I 118 I 119 I 120 I 121 I 122 123 1 124 I 125 I 126 127 I 128 I 129 I 130 , p1815 WIRE PULL w D cc U 65 w >� co O Z 0 CN 4103 CN 4102 Gas Sensor, Ammonia 0-250 ppm, GG-NH3_250 Gas Sensor NH3, 0-2%, GG-NH3-2% Gas Sensor, Vent Line, GG-VL2-NH3 Gas Detection Control Panel, GG-6 Uninterruplible Power Supply, UPS-1000VA-LCD Gas Detection Entrance Monitor, GG-EM Horn/Strobe, SHA-24_BLUE Remote Display, GG-RD CN 4101 Ammonia\Glycol Room HVP O r Z 0 SEPARATE PERMIT IREDMechanicFOelR: REf I— Electrical Plumbing Gas City aI TukwilaPiping BUILDING DIVISION Ec rc) 1 FAN i8 FAN N. 1 y .._ ' 'i t✓ / 'J Oa :. 1 /�i �.�c' _24 E &n.r ON s NOS OD OE as MOO lOIell NE Nl1aelNa M ae-alell M .R NW ID It NO Ile morsOo Re ■a RINK NNW St ws ee Maallr orNR! 2fla Iao atVIEVaEC Fo l r r, 2 7 2020 `'�� �Clty of Tukwila "4,.ynC.. BUILDING DIVISION A riEcElimn CITY of 'tU;eW!L A OCT 15 2019 PERMIT CENTER WAUKESHA, imm 9-63 (U 0 co Id, a M fL SWSTA WAORA. WA REIION 10015 'au 1e limns Innnnn Idle • ele PROCESS do INSTRUMENT. DIAGRAM MID D eel a PROCESS WIRE PULL 18815 WIRE PULL 0 I1 12 13 14 15 16 17 8 19 - I10 11 12 113 114 115 116 117 118 119 20 121 122 23 24 25 elr. a/-aalt 26 CAE 5 127 ' lee ' 129 Of et SA la SS aSS Me -Iae2 *3 130 31 ' 132 ' 0 11 2 13 4 5 16 17 8 9 12 . 113 114 15 116 117 118 19 120 121 122 23 . 124 125 126 27 128 _ 129 30 1 815 WIC PULL mmol s0 v CV) cu 0 n In 0) cu BLUE 14 AWG BLUE 14 AWG PAGE 5, HORN/STROBE SHA-24 BROWN 22 AWG BLUE 22 AWG WHT 22 AWG SHIELD PAGE 5, ENTRANCE MONITOR, GG-EM 413, 4131-, BLACK 22 AWG 413, 4130+, WHT 22 AWG SHIELD BLUE 14 AWG BLUE 14 AWG PAGE 5, HORN/STROBE SHA-24 BROWN 22 AWG BLUE 22 AWG WHT 22 AWG SHIELD PAGE 5, GAS SENSOR, GG-VL2-NH3 FAN51-SAFE, 10 HP 3ph/60Hz/460V BLUE 14 AWG BLUE 14 AWG PAGE 5, HORN/STROBE SHA-24 BROWN 22 AWG BLUE 22 AWG WHT 22 AWG SHIELD PAGE 5, GAS SENSOR, GG-VL2-NH3 FAN52-CONT, 2 HP 3ph / 60Hz / 460V BLUE 14 AWG BLUE 14 AWG PAGE 5, HORN/STROBE SHA-24 BLUE 14 AWG BLUE 14 AWG RS485 COMPLIANT CABLE PAGE 5, REMOTE DISPLAY, GG-RD BROWN 22 AWG BLUE 22 AWG WHT 22 AWG SHIELD PAGE 5, GAS SENSOR, GG-NH3-250 RED 14 AWG WHITE 14 AWG PAGE 5, UPS, UPS-1000VA-LCD BROWN 22 AWG BLUE 22 AWG WHT 22 AWG SHIELD PAGE 5, GAS SENSOR, GG-NH3-250 ETHERNET CABLE BROWN 22 AWG BLUE 22 AWG WHT 22 AWG SHIELD PAGE 5, GAS SENSOR, GG-NH3-2% 424, 2170, BLUE 14 AWG 424, 1200300, BLUE 14 AWG 425,1200301, BLUE 14 AWG 426, 1200302, BLUE 14 AWG 427, 1200303, BLUE 14 AWG 428, 1200304, BLUE 14 AWG 429, 1200305, BLUE 14 AWG BROWN 22 AWG BLUE 22 AWG WHT 22 AWG SHIELD PAGE 5, ENTRANCE MONITOR, GG-EM 400, 3 CONDUCTOR (22AWG) W/ SHIELD 402, 3 CONDUCTOR (22AWG) W/ SHIELD 403, 3 CONDUCTOR (22AWG) W/ SHIELD 404, 3 CONDUCTOR (22AWG) W/ SHIELD 406, 3 CONDUCTOR (22AWG) W/ SHIELD -- tio REVI€GJEC FOit 1 COMPLIANCE m I NFPA 70 • PIEC 0.UG 2 " 1021 1 City o1 TukwiI? aUILOING DIVISION nceFi e CITY C4:; T :;Rw LA OCT 15 2019 PERMIT CENTER v • (V O OS co n vt • N 11N Na MI) it S MOM telex MI IMPICIN NO OWNSUNID NOR M1ECOM loll NO R MI � U INK alas a MOW OF Na 114 moat ao Alas KHS. INC. WAUKESFA, WI SHASTA A MPIA. 1M " PROCESS & INSTRUMENT. DIAGRAM .. n 0 NOM 10010 0 1 12 13 4 5 16 17 8 9 12 113 114 15 116 - 117 - 118 19 - 120 121 122 23 - 124 125 A son woos oswairocols is000n a et to I - rs ore arc 26 27 ' 128 ' 129 PROCESS WIRE PULL Din 1n 18815 WIRE PULL uIt= 30 NW US Ie Ise 3 at 3 0 31 32 0 I1 _ 12 3 14 5 16 17 18 9 I10 11 12 113 114 115 116 117 118 _ 119 20 121 122 123 124 25 26 27 28 29 30 111815 WIC PULL 0 fU Cfs It 1' fU 0 0� m '0 In e A. B. C. D. E. F. G. H. Intake Vent to Room Gas Sensor, Ammonia 0-250 ppm, GG-NH3_250 Gas Sensor NH3, 0-2°/0, GG-NH3-2% Gas Sensor, Vent Line, GG-VL2-NH3 Gas Detection Control Panel, GG-6 Uninterruplible Power Supply, UPS-1000VA-LCD Gas Detection Entrance Monitor, GG-EM Horn/Strobe, SHA-24_BLUE Remote Display, GG-RD Ammonia\Glycol Room �H J RFMCP /10 \ / / \ \1 / .,. C;.;V 1. CITY IL:(WILA OCT 15 2019 ,s O.M. N. x MS /AI el NO Par EIK /VDst SO 10• OM EPOS t MIN OaINIONCID r V MS IN l Fct 00 PLLIAyN�C- vVl,:,.f III 2 7 2020 1 Chy of Tukwils BUILDING DIVISION I Aims KHS, INC. WAUKESHA, WI o • c� 0 0' m n ID v 01 SHASTA 1 REFROERCION sw PROCESS do INSTRUMENT. DIAGRAM PROCESS WIRE PULL 0 0 11 12 ' 13 ' 14 15 ' 16 17 18 19 ' 110 ' 111 ' 112 ' 113 ' 114 ' 115 ' 116 ' 117 ' 118 ' 119 120 ' 121 1 PERMIT CENTER 22 123 1 124 10015 25 A lln. rw I - NON 126 flws u�[ Dr 18815 WIRE PULL �x93.sems P° *MR _n wwrtr B 127 ' 128 129 —1,K1 043 N r SO /It SIf 130 31 1 132 0 0 L 9 10 12 14 1 E) :7 19 20 21 23 _24 25 26 27 28 29 30 1§,815 WIR PULL OUTDOOR TEMP TRANS 2-BLUE 16 AWG 2-BLUE 16 AWG GLYCOL SUPPLY LINE PRESSURE TRANSMITTER PT 5402 /14 \ / 2-BLUE 16 AWG / N".-"‘,-1-1,*--•!"1-1 460 VAC 460 VAC 460 VAC 34 AMP.3PH 19.6 AMP,3PH 19.6 AMP,3PH 8 AWG WIRE 10 AWG WIRE 10 AWG WIRE COMPRESSOR COOLING CONDENSER FAN 1 UP-4303 111 9 KW (T) 9 KW CONDENSER HEATER CONDENSER HEATER 2-BLUE 16 AWG HTR-4302 HTR-4301 HSD PRESSURE TRANSMITTER PT 4102 / 2-BLUE 16 AWG 15j HPL PRESSURE TRANSMITTER HPR SUCTION LINE GLYCOL BUFFER TANK PRESSURE TRANSMITTER PRESSURE TRANSMITTER LEVEL TRANSMITTER PT 4203 460 VAC 3.4 AMP,3PH 14 AWG WIRE 65 2 HP CONDENSER COOLING AMMONIA PUMP UP-4201 2-BLUE 16 AWG 460 VAC 11 AMP,3PH 14 AWG WIRE / \ 61/ 7.5HP CONDENSER COOLING WATER PUMP UP-4401 PT 4101 \ 460 VAC 100 AMP,3PH AWG WIRE 111 GLYCOL BUFFER TANK PUMP UP-5402 2-BLUE 16 AWG / \ 8 460 VAC 100 AMP,3PH 6 AWG WIRE A /A\ C59 40HP GLYCOL BUFFER TANK PUMP UP-5401 1-WHT 14 AWG 12-RED 14 AWG HIGH POWER WITH GROUND 3PH, 60 HZ, 480 VAC 400 AMP SERVICE 460 VAC 360 AMP,3PH 500 KCMIL WIRE I CN4103 COMPRESSOR MOTOR STARTER PANEL 1-WHT 14 AWG 12-RED 14 AWG 3 MOTOR LEADS & GND 500 KCMIL WIRE 1-WHT 14 AWG 12-RED 14 AWG / \4/ 1-WHT 14 AWG 12-RED 14 AWG +RFMCP MOTOR STARTER PANEL LT l /\ 5401 \ 9 GLYCOL RETURN TEMP TRANSMITTER TT 5402 GLYCOL SUPPLY TEMP TRANSMITTER PRESSURE TRANSMITTER TT 5401 GLYCOL SUPPLY LINE PT 5401 GLYCOL TANK TEMP TRANSMITTER TT 5403 LS 201 LS 4202 I V1 High Pressure Receiver 'AUTO -PURGER AP-4101 120 VAC. 15 AMP 26 1-WHT 14 AWG 1-RED 14 AWG SV-4101 HSS AUTO PURGE 1-WHT 14 AWG 460 VAC 360 AMP,3PH 500 KCMIL WIRE CN4102 COMPRESSOR MOTOR STARTER PANEL EM3 VILTER 4516XLB 300 HP BELT DRIVE 1-WHT 14 AWG 12-RED 14 AWG 3 MOTOR LEADS & GND 500 KCMIL WIRE 1-WHT 14 AWG 12-RED 14 AWG ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ +MCP PLC PANEL 48 AV-4001 7"--\ X-x SV-4001 AV-4002 X-X SV-4002 49 PT 4001 PT 4002 0 LS 4002 0 LS 4001 36 1-RED 14 AWG SV-4102 HPL LINE AUTO PURGE 1-WHT 14 AWG AMMONIA CHILLER TK-4001 1-RED 14 AWG SV-4303 FOUL GAS STRAINER/ SOLENOID VALVE 1-WHT 14 AWG 24 / 29 1-RED 14 AWG SV-4304 FOUL GAS STRAINER/ SOLENOID VALVE LINE A CP LINE A GLYCOL CHILLER 120 VAC, 5 AMP LINE B 460 VAC 180 AMP,3PH 3/0 AWG WIRE CN4101 COMPRESSOR MOTOR STARTER M2 VILTER 4516XLB 300 HP BELT DRIVE (3 MOTOR LEADS & GN 3/0 AWG WIRE M1 VILTER VMC448 150 HP EXISTING A' D O SV-4203 LIQUID RETURN VALVE KING VALVE E-SHUTOFF PUSHBUTTON 0 REMOTE E-STOP (NORTH EXIT) REMOTE E-STOP (SOUTH EXIT) REMOTE ALARM HORN 48 �\ REMOTE ALARM LIGHT HPR PUMP PRESSURE RELIEF 47 S SV-4202 KING SOLENOID VALVE FALSE LOAD VALVE PCV-4201 70 FAN CONTROL PANEL ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ LAB COMPUTER CP LINE B GLYCOL CHILLER i 120 VAC, 5 AMP 42 NEW EPROMIX NEW CAN LINE CP3 NEW CAN LINE GLYCOL CHILLER i 120 VAC. 5 AMP . 0 City of Tukwila UILDING DIVISION 0RRF4TION Cu o U-7 M 6" CO u- RECEIVE Y=TuKJ9,_ E► MI+ NOTE: ELECTRICAL CLASSIFICATION EQUAL NO CLASSIFICATION tlr %\ AKHS KHS, Ih . WAL'KESHA, WI SHASTA TUKWILA, WA REFRICE RATION PROCESS & INSTRUMENT. DIAGRAM PACJfC1. 18815 SC: PROCESS WIRE PULL PERMIT UPDATES MJH 6/25 20 c of rPE. > n f. KEFRIGERATF;N VTS ?G%JCr'a 5,7f.' 017/0 18815 WIRE PULL 10 11 12 13 14 17 18 119 20 2 r3 24 25 va, ?ft FASf cw ar: SJS AP! SJS Lc1; -1917. I Or: 3 126 127 I 128 I 129 130 131 I 132 1 110 111 I12 Intake Vent to Room 113 1'4 EVAPORATIVE CONDENSER amol 6u!Ioo3 r • • • • • • • 20 • • • CN4103 VERTICAL IGH PRESSURE RECEIVER 0 0 ^N` W • • CN4102 CN4101 3 3- 0) 0 0 3 GLYCOL TANK v AUTO PURGER () I15 New Switch Gear New Switch Gear Current Switch Gear Current Switch Gear MIINIMO Jossadwop i!V Water In -Feed 116 119 I 120 1 121 122 I I23 124 I25 [26 I27 128 I29 130 I1 815 WIffe PULL -1 VJ —1 VJ =co =co v r a) J�co UU 10 D 0 sOAleA .aossaaduo3 ;Novato/ .aossa.adwo3 oluowwy .aossaadwo3 oM�rL•u�c� .aossaadwo3 %%Noway I�It !1 .p itp: . ... 1ii:i11:ieuhilw. m 0 r Li • 4a3 gal d • to \/ pro PLI NFPA ran Gary thEA1 1lEl:t-iVEr) CITY Cell': I C:;:4 f.A OCT 15 20i9 PERM T CENTER }I n 0 H I1 a M fU 0 0 so lab C9 1111 MIS MO a* a MOON SI MM1 NM NOWIONINDO Ye NOR 10110011111 AWR w .-- n mat M NM. M6 awast AKHs WAUKESHA WI ISHASTA MAR WA 110102,101011 PROCESS & INSTRUMENT. DIAGRAM PROCESS WIRE PULL Mx M111-Malt INK IOW MUM I 186115 gar SINEWAMPWW3 Pm/Ma 1 12 3 4 5 6 7 8 9 10 11 12 113 114 115 116 117 118 19 120 21 122 123 24 25 26 27 128 129 JED 18815 WIRE PULL Mr= uwsus aer so 3 M^3 0 30 31 32 10 11 12 1 13 1 14 15 16 117 18 19 20 121 122 23 1 24 25 26 127 28 129 30 1 §815 WI i PULL 1 1 I 2118, 7001, WHT 14 AWG 2101, 21010, RED 14 AWG 2102, 21020, RED 14 AWG 2103, 21030, RED 14 AWG 2104, 21040, RED 14 AWG 2105, 21050, RED 14 AWG 2106, 21013, RED 14 AWG 2107, 21070, RED 14 AWG 2109, 21090, RED 14 AWG 2111, 21110, RED 14 AWG 2113, 21130, RED 14 AWG 2115, 21150, RED 14 AWG 2117, 21170, RED 14 AWG 1325, 8050, BLUE 14 AWG 1325, 1070901, BLUE 14 AWG 1107, 8050, BROWN 22 AWG 1107, 8051, BLUE 22 AWG 1107,1070104, WHT 22 AWG SHIELD AUTO -PURGER XXXX, XXXX, RED 14 AWG XXXX, XXXX, WHITE 14 AWG 1239, 0070604, BLUE 14 AWG 1239, 8051, BLUE/WHT 14 AWG 41 ETHERNET CABLE 1416, 0071202+, WHITE 22 AWG 1419, 0071202-, BLACK 22 AWG SHIELD ETHERNET CABLE 064 UP4404, 15 HP 3ph / 60Hz / 230-460V 2118, 7001, WHT 14 AWG 2101, 0080100, RED 14 AWG 2102, 1080900, RED 14 AWG 2103,1080901, RED 14 AWG 2104,1080902, RED 14 AWG 2105,1080903, RED 14 AWG 2106, 21013, RED 14 AWG 2107, 0080500, RED 14 AWG 2109, 0080501, RED 14 AWG 2111, 0080502, RED 14 AWG 2113, 0080503, RED 14 AWG 2115, 0080800, RED 14 AWG 2117, 7190, RED 14 AWG 1340, 8050, BLUE 14 AWG 1340,1071005, BLUE 14 AWG 1102, 8050, BROWN 22 AWG 1102, 8051, BLUE 22 AWG 1104, 1070102, WHT 22 AWG SHIELD AUTO -PURGER XXXX, XXXX, RED 14 AWG XXXX, XXXX, WHITE 14 AWG (34) 1240, 0070605, BLUE 14 AWG 1240, 8051, BLUE/WHT 14 AWG ETHERNET CABLE 1203, 1070701, BLUE 14 AWG 1103, 0070301, BLUE 14 AWG 628, 6281, BLUE 14 628, 6282, BLUE 14 629, 6291, BLUE 14 629, 6292, BLUE 14 24COM, 6051, WHITE/BLUE ETHERNET CABLE 2218, 7001, WHT 14 AWG 2201, 22010, RED 14 AWG 2202, 22020, RED 14 AWG 2203, 22030, RED 14 AWG 2204, 22040, RED 14 AWG 2205, 22050, RED 14 AWG 2206, 22013, RED 14 AWG 2207, 22070, RED 14 AWG 2209, 22090, RED 14 AWG 2211, 22110, RED 14 AWG 2213, 22130, RED 14 AWG 2215, 22150, RED 14 AWG 2217, 22170, RED 14 AWG 1337, 8050, BLUE 14 AWG 1337,1071002, BLUE 14 AWG 1111, 8050, BROWN 22 AWG 1111, 8051, BLUE 22 AWG 1109,1070106, WHT 22 AWG SHIELD AUTO -PURGER XXXX, XXXX, RED 14 AWG XXXX, XXXX, WHITE 14 AWG 1516, 8050, BLUE 14 AWG 1516,1071602, BLUE 14 AWG 1203,1070701, BLUE 14 AWG 1104, 0070302, BLUE 14 AWG 628, 6280, BLUE 14 628, 6281, BLUE 14 629, 6290, BLUE 14 629, 6291, BLUE 14 24COM, 6051, WH E/: U UP5401, 40 HP 3 MOTOR LEADS & GND 6 AWG WIRE UP4201, 2 HP HTR4301, 9 KW 3 MOTOR LEADS & GND 3 HEATER LEADS 14 AWG WIRE 10 AWG WIRE (74) 2218, 6001, WHT 14 AWG 2201, 0080200, RED 14 AWG 2202, 1081000, RED 14 AWG 2203, 1081001, RED 14 AWG 2204,1081002, RED 14 AWG 2205, 1081003, RED 14 AWG 2206, 22013, RED 14 AWG 2207, 0080600, RED 14 AWG 2209, 0080601, RED 14 AWG 2211, 0080602, RED 14 AWG 2213, 0080603, RED 14 AWG 2215, 0080801, RED 14 AWG 2217, 7200, RED 14 AWG 1125, 8050, BROWN 22 AWG 1125, 8051, BLUE 22 AWG 1126, 1070201, WHT 22 AWG SHIELD XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG 1515, 8050, BLUE 14 AWG 1515,1071601, BLUE 14 AWG 1009, 6050, BROWN 22 AWG 1009, 6051, BLUE 22 AWG 1009, 1070105, WHT 22 AWG SHIELD UP5402, 40 HP 3 MOTOR LEADS & GND 6 AWG WIRE HTR4302, 9 KW 3 HEATER LEADS 10 AWG WIRE 2318, 7001, WHT 14 AWG 2301, 23010, RED 14 AWG 2302, 23020, RED 14 AWG 2303, 23030, RED 14 AWG 2304, 23040, RED 14 AWG 2305, 23050, RED 14 AWG 2306, 23013, RED 14 AWG 2307, 23070, RED 14 AWG 2309, 23090, RED 14 AWG 2311, 23110, RED 14 AWG 2313, 23130, RED 14 AWG 2315, 23150, RED 14 AWG 2317, 23170, RED 14 AWG 1326, 8050, BLUE 14 AWG 1326,1070902, BLUE 14 AWG 1123, 8050, BROWN 22 AWG 1123, 8051, BLUE 22 AWG 1124, 1070200, WHT 22 AWG SHIELD C29 ETHERNET CABLE XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG XXXX, XXXX, XXX 14 AWG 45 1237, 0070602, BLUE 14 AWG 1237, 8051, BLUE/WHT 14 AWG 1514,1071600, BLUE 14 AWG 1514, 8050, BLUE 14 AWG UP4401, 7.5 HP 3 MOTOR LEADS & GND 14 AWG WIRE 1518, 8050, BLUE 14 AWG 1518,1071604, BLUE 14 AWG 2318, 7001, WHT 14 AWG 2301, 0080300, RED 14 AWG 2302, 1081100, RED 14 AWG 2303,1081101, RED 14 AWG 2304,1081102, RED 14 AWG 2305,1081103, RED 14 AWG 2306, 23013, RED 14 AWG 2307, 0080700, RED 14 AWG 2309, 0080701, RED 14 AWG 2311, 0080702, RED 14 AWG 2313, 0080703, RED 14 AWG 2315, 0080802, RED 14 AWG 2317, 7210, RED 14 AWG 1136, 8050, BROWN 22 AWG 1135, 8051, BLUE 22 AWG 1131, 1070206, WHT 22 AWG SHIELD 1113, 8050, BROWN 22 AWG 1113, 8051, BLUE 22 AWG 1110,1070107, WHT 22 AWG SHIELD ETHERNET CABLE 1237, 0070601, BLUE 14 AWG 1237, 8051, BLUE/WHT 14 AWG ETHERNET CABLE (6-2) UP4303, 20 HP 3 MOTOR LEADS & GND 8 AWG WIRE (6-9) 1517, 8050, BLUE 14 AWG 1517,1071603, BLUE 14 AWG 1237, 6050, BLUE 14 AWG 1237, 1071002, BLUE 14 AWG 1104, 8050, BROWN 22 AWG 1103, 8051, BLUE 22 AWG 1105,1070102, WHT 22 AWG SHIELD 1340, 8050, BLUE 14 AWG 1340,1071004, BLUE 14 AWG 1133, 8050, BROWN 22 AWG 1133, 8051, BLUE 22 AWG 1130, 1070204, WHT 22 AWG SHIELD 1414, 0071200+, WHITE 22 AWG 1419, 0071200-, BLACK 22 AWG SHIELD 1126, 8050, BROWN 22 AWG 1126, 8051, BLUE 22 AWG 1126, 1070202, WHT 22 AWG SHIELD UP4403, 15 HP 3ph / 60Hz / 230-460V 70 ETHERNET CABLE (8) 1324, 8050, BLUE 14 AWG 1324,1070900, BLUE 14 AWG 1106, 8050, BROWN 22 AWG 1105, 8051, BLUE 22 AWG 1106,1070103, WHT 22 AWG SHIELD AUTO -PURGER XXXX, XXXX, RED 14 AWG XXXX, XXXX, WHITE 14 AWG 1131, 8050, BROWN 22 AWG 1131, 8051, BLUE 22 AWG 1129,1070203, WHT 22 AWG SHIELD 1415, 0071201+, WHITE 22 AWG 1419, 0071201-, BLACK 22 AWG SHIELD 700, 7000, RED 14 AWG 700, 7001, WHT 14 AWG 800, 8000, BLUE 14 AWG 800, 8051, WHT/BLU 14 AWG 823, 8231, BLUE 14 AWG 823, 8232, BLUE 14 AWG 823, 8051, WHT/BLU 14 AWG 830, 8300, BLUE 14 AWG 831, 8310, BLUE 14 AWG 834, 8341, BLUE 14 AWG EC f oOMPLI�(JCEr, H MFPU 7C .. EC City of Tukwila BUILDING DIVISIGN 1217, 1070404, BLUE 14 AWG 1218,1070405, BLUE 14 AWG 1219, 1070406, BLUE 14 AWG 1220, 1070407, BLUE 14 AWG 1317,1070804, BLUE 14 AWG 1318,1070805, BLUE 14 AWG 1319,1070806, BLUE 14 AWG 1320, 1070807, BLUE 14 AWG 1424, 1071300, BLUE 14 AWG 1425, 1071301, BLUE 14AWG 1426, 1071302, BLUE 14 AWG 1438, 1071402, BLUE 14 AWG 1439, 1071403, BLUE 14 AWG 1440, 1071404, BLUE 14 AWG 1241, 1071405, BLUE 14 AWG ETHERNET CABLE 0-11- DV\ A dmis KI-IS, INC. WAUKESHA, WI S-AS A yFF- GEPATI3N PROCESS & INSTRUMENT. DIAGRAM PROCESS WIRE PULL PERMIT UPDATES MJH 8/25/20 FF-1 ,1 1 18815 WIRE PULL 1 4 l 14 15 I 116 18 19 20 1 121 1 122 1 23 24 25 26 127 1 28 129 30 31 32