Permit EL19-0888 - WESTFIELD SOUTHCENTER MALL / RESTROOMS - DEMO LIGHTING AND ELECTRICAL FIXTURES, HOT WATER HEATER POWER, ETC
SOUTHCENTER MALL- RESTROOMS 2800 SOUTHCENTER MALL ELI 9-0888 Parcel No: Address: City of Tukwila a ent of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwfla, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 3597000150 Permit Number: EL19-0888 2800 SOUTHCENTER MALL Project Name: SOUTHCENTER MALL - RESTROOMS Issue Date: 12/23/20I9 Permit Expires On: 6/20/2020 Owner: Name: Address: ''WA, Contact Person: Name: STONE FAISON Address: 1326 FIFTH AVE SUITE 400'SEATTLE, WA, 98101 Contractor: Name: NEW LIFE ELECTRIC LLC Address: lOI38NEl44THPL,K|RKLAND'WA, 98034 License No: NBmULE892JH Lender: Name: Address: ''' Phone: (206) 342-0121 Phone: (206) 755-3606 Expiration Date: 4/8/2021 DESCRIPTION OF WORK: THIS PROJECT REQUIRES DEMOLITION OF EXISTING LIGHTING AND ELECTRICAL FIXTURES, LOW VOLTAGE FIXTURES FOR TOILETS AND WATER COOLERS AS WELL AS POWER FOR THE HOT WATER HEATER. NEW FIXTURES POWERED THROUGH EXISTING PANEL. Valuation ofsingle family: $0.00 Valuation of mf/cornm: $63,000.00 Type of Work: TENANT IMP Fees Collected: $1,55710 Electrical Service Provided by: Water District: Sewer District: Current Codes adopted by the City of Tukwila: International Building Code Edition: lnternational Residential Code Edition: Irfternational Mechanical Code Edition: Uniform Plumbing Code Edition: 2015International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 I hearby certify that | have read and examined this permit and know the same to be true and correct. AD provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:' Date:Print Name: 1202, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last irispection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical lnspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438f9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWC Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: 101.'?` Date Application Expires: )„.1, --)—ti (For office use onlv) 0 0 ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 920247-0010 site Address: 2800 Southcenter Mall, Seattle, WA 98188 Suite Number: Tenant Name: Unibail-Rodamco-Westfield New Tenant: PROPERTY OWNER Name: Stone Faison Name: Unibail-Rodamco- es ield City: Seattle State: WA Zip: 98101 Address: 2800 Southcenter Mall Email: StoneF@BurgessPNW.com City: Seattle State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Stone Faison Address: 1326 Fifth Ave, Suite 400 City: Seattle State: WA Zip: 98101 Phone: 206.342.0121 Fax: Email: StoneF@BurgessPNW.com Floor: 1 El Yes ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 63,000 Scope of Work (please provide detailed information): This project requires demolition of existing lighting and electrical fixtures, low voltage fixtures for toilets and water coolers as well as power for the hot water heater. New fixtures powered through existing panel. Will service be altered? El Yes No Adding more than 50 amps? [7.] Yes El No Type of Use: Restroom Type of work: ID New 0 Addition 0 Service Change 0 Remodel [it Tenant Improvement 0 Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: Puget Sound Energy 0 Seattle City Light WAPermit C,enter Applications-Handouts‘Permit ApplicationAPDMElectrical Permit Application Revised 1-17-19.docx PI C71. 1 rd RESIDENTIAL NEW RESIDENTIAL SERVICE O New single family dwellings $180.00 (including an attached garage) EJ Garages, pools, spas and outbuildings $120.00 ea O Low voltage systems (alarm) $60,00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES O Service change or alteration ......... ...... . ...... $120.00 (no added/altered circuits) o Service change with added/altered circuits .$100.00 number of added circuits $10.00 ea O Circuits added/altered without service change $60.00 (up to 5 circuits) O Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea O Meter/mast repair $80.00 O Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $60.00 O Temporary service (generator) $90.00 O Manufactured/mobile home service $100.00 (excluding garage or outbuilding) O Carnivals $100 00 Number of concessions $1 1.00 ea Each ride and generator truck $11.00 ea * * * EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Pemnt Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Stone Faison Mailing Address: 1326 Fifth Ave, Suite 400 Date: 10.29.19 Day Telephone: 206.342.0121 Seattle WA 98101 WAPertnit CenteMpplications-liandouts \Remit ApplicationAPDFAElectrical Permit Application Revised 1-17-19.docx City State Zip Pq OP of DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $1,265.15 EL19-0888 Address: 2800 SOUTHCENTER MALL Apn: 3597000150 $1,265.15 Credit Card Fee $36.85 Credit Card Fee R000.369.908.00.00 0.00 $36.85 ELECTRICAL $1,169.81 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,169.81 TECHNOLOGY FEE $58.49 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R19366 R000.322.900.04.00 0.00 $58.49 $1,265.15 Date Paid: Monday, December 23, 2019 Paid By: NEW LIFE ELECTRIC LLC Pay Method: CREDIT CARD 143795 Printori• NAnntiaw 11PromhPr y?ni R•VI AM 1 of 1 "IP CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 12/23/2019 08:39:15 AM CREDIT CARD SALE VISA CARD NUMBER: **********1841 K TRAN AMOUNT: $1,265.15 APPROVAL CD: 143795 RECORD #: 000 CLERK ID: Bill X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY I PAID $358.62 EL19-0888 Address: 2800 SOUTHCENTER MALL Apn: 3597000150 $292.45 ELECTRICAL $292.45 PLAN CHECK FEE R000.345.832.00.00 0.00 $292.45 M19-0180 Address: 2800 SOUTHCENTER MALL Apn: 3597000150 $66.17 MECHANICAL $66.17 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R18940 R000.322.102.00.00 0.00 $66.17 $358.62 Date Paid: Tuesday, October 29, 2019 Paid By: BURGESS DESIGN INC Pay Method: CHECK 016849 Printed: Tuesday, October 29, 2019 3:25 PM 1 of 1 CRIP11011rSYSTEM INSPECTION RECORD Retain a copy with permit INSPECTION NO. P REIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project rT of Inspection: J' Address. Date Called: SpecialIns tructions: Date anted: a.rn. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prim to approval. nspec REINSPECTI N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd_. Suite 100. Call to schedule rei spection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PRMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Special Instructions: Approved per applicable codes. © Corre ns required prior to approval. COMMENlTS: go, � l ",_ Inspector: Date: REINSPECTI©I+lf FEE REQUIRED. Prior to next inspection, fee frau §t be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. qERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0888 DATE: 10/3012019 PROJECT NAME: SOUTHCENTER MALL - RESTROOMS SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: de kV IC6 Eruilding Divison Public Works EIJ Fire Prevention Structural r Planning Division FlPermit Coordinator LI • PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/31/19 Structural Review Required REVIEWER'S INITIALS: DA 1E: LIi APPROVALS OR CORRECTIONS: Approved DUE DATE: 11/28/2019 Approved with Conditions E Corrections Required LJ Denied (corrections entered in Reviews) (ie: Zoning Issues) LI Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 Labor & riclustries (htips://lni.wa.clov) Cot &actors ElW LIFE ELECTRIC LLC Owner or tradesperson DORE, ANTHONY Principals DC RE, ANTHONY, PARTNER/MEMBER DCRE, JENNIFER A, PARTNER/MEMBER DORE, ANTHONY, AGENT Doing business as NEN LIFE ELECTRIC LLC WA UBI No, 6V 100 822 10138 NE 144TH Place KIRKLAND, WA 98034 206-755-3606 KING County Business type Limited Liability Company Governing persons ANTHONY DORE ::ense Veri/; the contractor's active registration / license / certification (depending on trade) and any past violations. Elci:trical Contractor Active Meets current requirements. Liconse specialties GENERAL Liciinse no. NEWLILE892JH Effective — expiration 04/08/2011— 04/08/2021 DeSignated administrator Dere, Anthony A Active Meets current requirements. License type License no. Master Electrician DORE'AA920PB Bend ....„ Ohio Cas Ins Co Bond account no. 251588C Re ;eived by L&I 08;26/2019 ie Bons) history ........... No.iiavings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. ifications & Endorsements OMWBE Certifications No octive certifications exist for this business. App Training Agent Not allowed to have apprentices. $4,000.00 Effective date 08/26/2019 Expiration date Until Canceled GENERAL SYMBOLS DETAILS SHEET NOTE LIGHT LINE INDICATES BACKGROUND LIGHT LINE INDICATES EXISTING WORK HEAVY LINE INDICATES NEW WORK MATCHLINE OR PROPERTY LINE LIGHT LINE WITH HEAVY X INDICATES x x * EXISTING WORK TO BE REMOVED / / / / / EXISTING WORK TO BE ABANDONED X K X SECTION IDENTIFICATION INDICATES DIRECTION OF CUTTING PLANE LETTER INDICATED SECTION SHEET NUMBER WHERE SECTION IS DRAWN RACEWAYS DETAIL IDENTIFICATION NUMBER INDICATES DETAIL SHEET NUMBER WHERE DETAIL IS DRAWN ELEVATION IDENTIFICATION NUMBER INDICATES ELEVATION SHEET NUMBER WHERE ELEVATION IS DRAWN CONDUITS CONCEALED IN CONSTRUCTION IN FINISHED AREAS, EXPOSED IN UNFINISHED AREAS — — — — — CONDUIT CONCEALED IN OR UNDER FLOOR SLAB RACEWAYS - INDICATORS 0 2'C4#1+1#6GND (2) 2"C 4#1 + 1#6 GND 1211/1,3 LIGHTING FIXTURES O❑A Iesi 4 9 ❑ 0 a 2 a 2 10 +48 CONDUIT STUB. TERMINATE WITH BUSHING OR CAP IF UNDERGROUND CONDUIT TURNING UP CONDUIT TURNING DOWN INDICATES TRADE SIZE 2" CONDUIT WITH (4) #1 AWG AND (1) #6 AWG GROUND INDICATES (2) TRADE SIZE 2' CONDUITS WITH (4) #1 AWG AND (1) #8 AWG GROUND CONDUCTORS IN EACH CONDUIT HOMERUN TO PANELBOARD. NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS. (EXAMPLE: HOMERUN TO PANEL L211 CKTS. #1 AND #3) LUMINAIRE: DRAWN TO APPROXIMATE SHAPE AND TO SCALE OR LARGE ENOUGH FOR CLARITY EXIT LIGHTING FIXTURE, ARROWS AND EXIT FACE AS INDICATED ON DRAWINGS (MOUNTING HEIGHTS TO BE DETERMINED BY PROJECT SPECIFICATIONS) WALL MOUNTED FIXTURE (SIZED TO SCALE) LUMINAIRE PROVIDING EMERGENCY ILLUMINATION STANDARD DESIGNATIONS FOR ALL LIGHTING FIXTURES = FIXTURE TYPE, REFER TO FIXTURE SCHEDULE "2' = CIRCUIT NUMBER "a' = SWITCH IDENTIFICATION MOUNTING HEIGHT INTERIOR = AFF EXTERIOR = AFG POWER 0' 0' as JUNCTION BOX EQUIPMENT CONNECTION FUSED DISCONNECT SWITCH UNFUSED DISCONNECT SWITCH PANELBOARD - 240V OR 208V LIGHTING OR POWER PANEL (SIZED TO SCALE) PANELBOARD - 480V LIGHTING OR POWER PANEL (SIZED TO SCALE) TRANSFORMER (SIZED TO SCALE) OUTLETS AND RECEPTACLES x SWITCHES $K 0 FIRE ALARM © 4 A CM 0 COMMUNICATION OM DIAGRAM i —ate® LlU..A.) Yrr n ts Y 1Y (3) 400:5A 0 NAME AMPS POLE DUPLEX CONVENIENCE RECEPTACLE SINGLE POLE SWITCH KEY OPERATED SWITCH CEILING MOUNTED OCCUPANCY SENSOR WITH OFF -AUTO OVERRIDE SWITCH HORN STROBE FIRE ALARM HORN MANUAL PULL STATION STROBE CONTROL MODULE CONTROL RELAY INTERCOM STATION SUBSCRIPT INDICATES: M = MASTER SPEAKER SUBSCRIPT INDICATES: X = ZONE GENERATOR GROUND FUSED DISCONNECT SWITCH POWER TRANSFORMER DELTA CONNECTION WYE GROUNDED WYE CT TRANSFORMER SUBSCRIPT INDICATES: 3 = QUANTITY 400:5A = RATIO AUTOMATIC TRANSFER SWITCH FEEDER CALLOUT CIRCUIT BREAKER DISCONNECT SWITCH ABBREVIATIONS A AC ADA AHU AIC AFF AP ARCH ATS BLDG BRKR C CB CKT CLG. C.O. COL CONC CONTR CR CS CT CTL CU DC DDC DET DIA DIAG DISC. ON DWG EA EF EL ELEC EMERG EMT EOL EWC EXP EXIST. FA FACC FACP FDR FIN FIO FIXT FLEX FLR FLUOR FOIC FT FU FUT GALV GEC GEN GFI GND H HH HID HOA HP HPS HZ WO IAC IC ID IN INST J-BOX KCMIL KVA KW L LAB LC LT LTG AMPS ALTERNATING CURRENT AMERICANS WITH DISABILITIES ACT AIR HANDLING UNIT AMPS INTERRUPTING CAPACITY ABOVE FINISHED FLOOR TO C OE DEVICE OR OUTLET BOX ACCESS PANEL ARCHITECTURAL AUTOMATIC TRANSFER SWITCH BUILDING BREAKER CONDUIT; CABLE; COIL CIRCUIT BREAKER CIRCUIT CEILING CONDUIT ONLY COLUMN CONCRETE CONTRACTOR CONTROL RELAY CONTROL SWITCH CURRENT TRANSFORMER CONTROL COPPER DIRECT CURRENT DIRECT DIGITAL CONTROL DETAIL DIAMETER DIAGRAM DISCONNECT DOWN DRAWING EACH EXHAUST FAN ELEVATION ELECTRICAL EMERGENCY ELECTRICAL METALLIC TUBING END OF LINE DEVICE ELECTRIC WATER COOLER EXPOSED EXISTING FIRE ALARM FIRE ALARM CONTROL CONSOLE FIRE ALARM CONTROL PANEL FEEDER FINISHED FURNISHED AND INSTALLED BY OWNER FIXTURE FLEXIBLE FLOOR FLUORESCENT FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR FEET; FOOT FUSE FUTURE GALVANIZED GROUND ELECTRODE CONDUCTOR GENERATOR GROUND FAULT INTERRUPTING GROUND HIGH (DIM) HANDHOLE HIGH INTENSITY DISCHARGE HAND -OFF -AUTOMATIC HORSEPOWER HIGH PRESSURE SODIUM HERTZ INPUT/OUTPUT PANEL INTERLOCKED ARMORED CABLE INTERRUPTING CAPACITY INSIDE DIAMETER INCH INSTANTANEOUS JUNCTION BOX THOUSAND CIRCULAR MILS KILOVOLT AMPS KILOWATT LONG LABORATORY LIGHTING CONTACTOR LIGHT LIGHTING MCC MCP MECH MFR MH MIN MLO MTD MTG MTR MTS MVA N.C. NEUT NIC N.O. NO. NTS OD PA PAR PC PF PH PL PNL POC PT PVC PWR QTY R REC RECEP RGS RM RQMTS SECT SFD SHLD SHT SPEC SQ STD STL STR SUBST SURF SW SWBD SWGR T TB TC TEL TEMP TP TSP TYP UG UON UH UV V VA VS W W/ WIo WF WP WT XFER XFMR XMTR Z 0 MOTOR CONTROL CENTER MOTOR CIRCUIT PROTECTOR MECHANICAL MANUFACTURER MANHOLE; METAL HALIDE MINIMUM MAIN LUGS ONLY MOUNTED MOUNTING MOTOR MANUAL TRANSFER SWITCH MEGAVOLT-AMPS NORMALLY CLOSED NEUTRAL NOT IN CONTRACT NORMALLY OPEN NUMBER NOT TO SCALE OUTSIDE DIAMETER PUBLIC ADDRESS PARALLEL PHOTO -ELECTRIC CELL; PULL CHAIN; PERSONAL COMPUTER POWER FACTOR PHASE PROPERTY LINE PANEL; PANELBOARD POINT OF CONNECTION POTENTIAL TRANSFORMER POLYVINYL CHLORIDE POWER QUANTITY RADIUS; RISER RECEPTACLE RECEPTACLE RIGID GALVANIZED STEEL CONDUIT ROOM REQUIREMENTS SECTION SMOKE FIRE DAMPER SHIELDED SHEET SPECIFICATION SQUARE STANDARD STEEL STRANDED SUBSTATION SURFACE SWITCH SWITCHBOARD SWITCHGEAR TRANSFORMER TERMINAL BLOCK TERMINAL CABINET TELEPHONE TEMPORARY; TEMPERATURE TWISTED PAIR TWISTED SHIELDED PAIR TYPICAL UNDERGROUND UNLESS OTHERWISE NOTED UNIT HEATER UNIT VENTILATOR VOLT(S) VOLT-AMPERES VERTICAL SCALE WATT(S), WIRE(DIM) WITH WITHOUT WATER FLOW ALARM WEATHERPROOF WATERTIGHT TRANSFER TRANSFORMER TRANSMITTER ZONE; IMPEDENCE NUMBER PHASE SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA98188 BURGESS DESIGN I NTERlORT • ARCHITECTURE At reprobation ! et1.e..ttr.l prow* Aphis rolw..d a 2017 REVISIONS • e S'.:ooe Sutra Uc r' SEPARATE PERMIT REEUIRED FOR: Mechanical Er Electrical Plumbing 01 Gas Piping City of Tukwila BUILDING DIVISION al` . 'evreW FILE COPY Ponta No. ii‘C‘6)1 11 t 1�7J Plan review approva: Is suplect to errors dto omissons .Approval et consuuci:on oocuments Toes ur autncnze r^e v.c arson of ary a3errs C.-ce o. 3rd,nance Rr.-:>:p; 9t 3uu':1veC on s a; now'e.Nec By C;,'J L31 /e1 Owe__ Wood Harbinger 929 to8th Ave NE, Suite woo Bellevue. WA 9Boo4 425.628.6000 woodharbioger.com Professional Beal REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City swim* Stang Location fEVIEWEc Fora ! { COMNFPA 70 PLIANCE" 1MT.i !If -• WEC f City of Tukwlra BUILDING DIVISION Drown by IAK Project Manager: RM PrcJ.ct Na: 19.0168.00 ELECTRICAL SYMBOLS & ABBREVIATIONS oryw Ia, Y 2." x 31r. Seer. oaks .o..raly $ Nana E.0.1 ELtR - og88 AC PENTHOUSE #7 (ON ROOF) 1 I I L 75KVA XFMR LDB SEC. 3 LDB SEC. 1 LDB SEC. 2 HDB SEC.1 HDB SEC. 2 RC I u I u I le O 00 I c ■ 1 Lo p AREA OF WORK OVERALL ELECTRICAL PLAN 6 LMlUL_Fl I I 0 16' 32' 48' 1/16" = 1'- 0" SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 BURGESS DESIGN INTERIORS • ARCHITECTURE Al npetolim 6t InIsbabad .-a t MSS mired a 2017 Wood Harbinger 929 roSth Ave NE, Suite wooBellevue. WA 98004 425.6t8.6000 woodharbinger.com Professional seal REVIEW SET 09.16.19 PRICINGS SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City EMatronlc Stomp Location �. fR pIE�NCCEFN P.470 'AEG WV 2G 2019 EL14--0889 ctiyol Tukwila I.111.DING DIVISION I Drown by: MN Project Manager RM Project No: 19.0188.00 OVERALL ELECTRICAL PLAN OrI f I drawly Y 24' x 36'. Ses wee ealrandle61/ 0 rrtnd E.1.0 (E) FAUCET (E) WATER HEATER LDB SEC 3/2 LDB SEC 3/1--�_ (E) FAUCET LDB SE LDB SEC 3/8 G (E) TOILET LOB SEC 3/6 (E) TOILET LDB SEC 3/6 (E) TOILET LDB SEC 3/ (E) TOILET LDB SEC 3/6 (E) HAND DRYER LDB SEC 319 (E) WATER COOLER LDB SEC 3110 (E) FAUCET LDB SEC 3/2 (E) WATER COOLER LDB SEC 3112 (E) FAUCET LDB SEC 3/2 (E) HAND DRYER LDB SEC 3/11 LDB SEC 3/8 0- G (E) URINAL LDB SEC 3/6 (E) URINAL LDB SEC 3/6 (E) TOILET LDB SEC 3/6 (E) TOILET LDB SEC 3/6 r ENLARGED DEMOLITION POWER PLAN f�l-I 1/4" 0 4' 8' 12' (E) WATER HEATER HDB SEC 2/38 n O.Q ENLARGED DEMOLITION SYSTEMS PLAN 0 I I 4' 8' 12' 1/4" = 1'— 0" 0 HDB SEC 1135 HOB SEC 1/35 0 HDB SEC 1/35 HDB SEC 1/35 HOB SEC 1/35 HDB SEC 1/35 HDB SEC 1/35 HDB SEC 1135 HDB SEC 1/35 n n Z n: (D 0 LDB SEC 111 0 LDB SEC 1/1 HDB SEC 1/35 0 LDB SEC 1/1 LDB SEC 111 0 LDB SEC 1/1 N LDB SEC 111 fff 0 LDB SEC 1/1 OO LDB SEC 111 L xs HDB SEC 1/35 HDB SEC 1/35 11 HDB SEC 1/35 64 1DBSEC111 tips r LDB SEC 1/1 0 LDB SEC 1/1 0 LDB SEC 111 ENLARGED DEMOLITION LIGHTING PLAN 11 0 4' 8' 12' 1/4" = 1'- 0" GENERAL NOTES: 1. REFER TO ARCHITECTURAL FOR ADDITONAL DETAILS. 2. TRACE AND VERIFY ALL REVISED CIRCUITING PRIOR TO DEMOLITION. SHEET NOTES: RELOCATE SPEAKER. ELftO�B 8 SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800SOUTHCENTER MALL TUKWILA, WA 98188 B BURGESS DESIGN INTERIORS • ARCHITECTURE M Npt&otlon s ;vitiated wily nib R..R..e0 o 2017 Wood Harbinger 929 Eo8th Ave NE. Suite 1000 Bellevue. WA 98004 425.628.6o00 woodharbinger.com Professional seal No. Issue D..atptlon Dab REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 ate Electronic Stamp location r REVIL--WED FSFt I iOOMPLt NCE THI } NM:1:1 NotC, k3D 2: 1019 Ghy or-ukwila rtVILDING DIVISION Drown br• MK Proj.ct Mo ng.r: RM Proj.ct No: 19.0188.00 ENLARGED DEMOLITION ELECTRICAL RESTROOM PLAN Original Saabs M 24 a 7S'. Scab rem maim* S 'educed E.1.1 P-10 LDB SEC 318 LDB SEC 319 LDB SEC 3/2 LDB SEC 3/2 LDB SEC 3111- LDB SEC 3/2 LDB SEC 312 of C O LDB SEC 312 LDB SEC 3/2 LDB SEC 3113 LDB SEC 3/2 LDB SEC 3/2 LDB SEC 3/15 P-2 P-2 P-2 P-2 J LDB SEC 318 P-4 P-4 P-2 P-2 0- ENLARGED POWER PLAN m n I I 0 4' 8' 12' 1/4" = 1'- 0" 0 O O n u u C ENLARGED SYSTEMS PLAN 0 4' 8' 12' 1/4" = 1'- 0" 104 r HDB SEC 1/35 C) HDB SEC 1135 (L4 HDB SEC 1/35 HDB SEC 1/35 r HDB SEC 1/35 HDB SEC 1135 00 HDB SEC 1/35 L2 (c) LDB SEC 111 / tR LDB SEC 1/1 0 0 LDB SEC 1/1 LDB SEC 111 HDB SEC 1/35 HDB SEC 1/35 f LDB SEC 111 L3 >--- LDB SEC 1M 0 LDB SEC 1! co:1 O UU L3 07-0 r HDB SEC 1135 te- LOB SEC 1/1 O LDB SEC1/1 J< L2 LOB SEC 111 J D O LDB SEC 1M 0 0 LDB SEC 111 0 LDB SEC 111 0 LDB SEC 1/1 ENLARGED LIGHTING PLAN 0 4' 8' 12' 1 /4" = 1'- 0" GENERAL NOTES: 1. REFER TO ARCHITECTURAL FOR ADDITONAL DETAILS. SHEET NOTES: PROVIDE ACCESS PANEL FOR RELOCATED ELECTRICAL EQUIPMENT. ELtRO 889 OCT53-1:IT 29 _I.5 SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 W UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 BURGESS DESIGN INTERIORS • ARCHITECTURE AI repe01m0Rn ! MiaYd pepey dike reeereed a 2017 Wood Harbinger 929 loath Ave NE, Suite moo Bellevue. WA 98004 425.628.6000 woodharbingercom Professional seal No. ken Deecdptlon Data REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City Beetronk Stamp Location REVIEWED FOR `COMPLIANCE W ; i NFPA 70 - NEC 1'' 2 E 2019 :By of Tukwi', c.UILDING DIVISIOti Dram by: MK Project Manager RM PrnJtat No: 19.0168.00 ENLARGED ELECTRICAL RESTROOM PLAN Ott rr •awlS b 21' x JS'. as. gala taxed py II resmee E.2.1 • CEN T iR AC PENTHOUSE#7 UTILITY COMPANY METER PAD MOUNTED UTILITY TRANSFORMER (PROVIDED BY PSE) PANEL LDB SEC. 3 208Y/120V 30,4W PANEL LDB SEC. 1 208Y1120V 30.4W PANEL LDB SEC. 2 208Y1120V 30,4W XFMRXX A 75 KVA mm V 480: 208Y/120V 30,4W PANEL PANEL HDB HDB SEC.1 — SEC.2 480Y1277V 480Y1277V 30,4W 30,4W T � 2000A FIRST FLOOR TO PNL TO PNL TO PNL TO PNL TO PNL TO PNL TO PNL TO PNL TO PNLTO PNL LHD HJB HHA HDA HHB PA HGA HJA HKA PB -- -- — -- — -- ---- — -- jA (200A C 400A \ 600A (400A \ 400A \ 400A (100A (400A ( 400A (600A I1 1 I 1 11 SERVICE POINT ELECTRICAL ONE -LINE DIAGRAM MAIN SWITCHBOARD 2000A, 480Y/277V, 30, 4W, 65 KAIC GENERAL NOTES: 1. ALL ELECTRICAL EQUIPMENT SHOWN ARE EXISTING UNLESS NOTED OTHERWISE. SHEET NOTES: PANEL AFFECTED BY THIS PROJECT. ELt9O 88$ SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 1 BURGESS DESIGN INTERIORS • ARCHITECTURE M npoduclkn it eda4anral er.Ort7 Arita ntror. d o 2017 Wood Harbinger gag loath Ave NE, Suite i000 Bellevue, WA 0004 425.628.6000 woodharbingercom Prof000kmd not No. Sus D.eeriptbn Date REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City D.atronto Stamp Location 1 taw:. 96 yFc 2C2019 "t ,of ;uKWll'A y ICIf,^. Drawn by. MK Project Manager RM Project No: 19.0168.00 ELECTRICAL ONE -LINE DIAGRAM onrar teat, la M' * W. Sods San aa....a 4 W Said E.5.1 LUMINAIRE SCHEDULE TYPE DESCRIPTION MODEL LAMPS WATTS LUMENS MOUNTING VOLTAGE REMARKS L1 2' SQUARE DOWNLIGHT GOTHAM: ICO SQADJ-30-15-2AR-FL-LSS-45D LED 3500K 22 1500 RECESSED UNIV 1201277V L2 COVE LIGHT AXIS: BBPRLED-400-90-35-FL-X-W-UNV-DP-1-DF LED 3500K 3.61FT 400/FT COVE UNIV 120127N OWNER PROVIDED L3 WALL SCONCE TRADE WINDS WIRE CAGE LED WALL SCONCE: 161101 LED 3500K 100 SURFACE UNIV 120/277V L4 2X2 TROFFER LED 3500K RECESSED UNIV 120127N MOTOR AND EQUIPMENT WIRING SCHEDULE EQUIPMENT ID HP/KW VOLTS PH PANEL WIRE CONDUIT DISCONNECT SIZE FUSE STARTER NEMA COMB'N REMARKS DESCRIPTION AMPS AMPS SIZE YES NO P-2 TOILET 0.1KW 120 1 LDB SEC 3 2#12, 1#12 EGC 3/4" X P-4 URINAL 0.1KW 120 1 LDB SEC 3 2#12, 1#12 EGC 3/4" X P-10 DRINKING FOUNTAIN 0,46KW 120 1 LDB SEC 3 2#12, 1#12 EGC 3/4" X WH-1 WATER HEATER 6.0 KW 480 3 HDB SEC 2 2#12, 1#12 EGC 3/4" 30 X EL1 9o899 SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800SOUTHCENTER MALL TUKWILA, WA 98188 BURGESS DESIGN INTERIORS • ARCHITECTURE nice-mtlen t MrIEtlRadr i pops* rljrb nunwd . tlD/7 Wood Harbinger 929 io8th Ave NE. Suite woo Bellewe, WA Sod 425.628.600a woodharbinger.com Profewloral seal No. issue oaEatpdon Date REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.18.19 City Electronic Stamp Location REl/f-"'- tN'ferr li.T i 6 "$;1 ,�NC 4EG �s�c v - 21Z019 c y ofluxwdt olVisION Drove h^• MK Project Manager: RM Project No: 19.0168.00 ELECTRICAL SCHEDULES M S droving Is u c 7.". Sob MIS ...Franey II reduced E 6.1 PANEL NAME: MAIN SWITCHBOARD LOCATION: ELECTRICALRM FED FROM: UTILITY kAIC SYM 2000 AMP PANEL SCHEDULE 480Y1277 VOLT SECTION: 1 OF 1 3 PHASE, 4 WIRE FLOOR MOUNT SWBD MAIN FUSED SW 2000 AMP BUS CU BUS MFGR: CAT # 100% NEUTRAL CU, NO. CIRCUIT DESCRIPTION CB kVA P H kVA CB CIRCUIT DESCRIPTION Ckt No. AMPS POL AMPS POL 1 PNL LHD 2001 3 0.00 a 0.00 4001 3 PNL PA 2 - • 0.00 b On - - - 0.00 c 0.00 - - 3 PNL HJB 4001 3 0.00 a 0.00 100/ 3 PNL HGA 4 - • 0.00 b On - - - 0.00 c O.00 - • 5 PNL HHA 6001 3 0.00 a 0.00 4001 3 PNL HJA 6 - • 0.00 b 0.03 - • - 0.00 c O.00 - - 7 PNL HDA 4001 3 0.00 a 0.00 4001 3 PNL HKA 8 - • 0.00 b 0.00 - • - 0.00 c 0.00 - - 9 PNL HHB 400/ 3 0.00 a 0.00 600/ 3 PNL PB 10 - - 0.00 b O.00 - - . - 0.00 c On- - 11 PNL HDB 4001 3 6.41 a 0.00 12 • - 4,96 b O.00 • - 6.97 c 0A0 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. NOTES SHOWN. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT MOTOR 2.26 kVA 125% 0.36 kVA 50%>10kVA 0.00 kVA 100% 0.00 kVA 125% 0.00 kVA 100% 15.72 kVA 100% 0.00 kVA 0% 2.83 kVA 0.36 kVA 0.00 kVA 0.00 kVA 0.00 kVA 15.72 kVA 0,00 kVA EXISTING CONDITION TOTAL 18.34 kVA 22.1 AMPS 18.91 kVA 22.7 AMPS PANEL NAME: HOB SEC. 1 (EXIST) LOCATION: AC PENTHOUSE #7 (ROOF) FED FROM: MAIN SWITCHBOARD kAIC SYM 400 AMP PANEL SCHEDULE MFGR: 480Y/277 VOLT SECTION: 1 OF 1 CAT # 3 PHASE, 4 WIRE SURFACE MOUNT PNL MLO 400 AMP BUS CU BUS 100% NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB kVA P H kVA CB CIRCUIT DESCRIPTION Ckt No. AMPS POL AMPS POL 1 PRIH-24 15/ 3 0.00 a 0.00 15/ 3 PWR-7 2 3 - • 0.00 b 0.00 - - 4 5 - • 0.00 c 0.00 • - 6 7 PRIR-7 15/ 3 0.00 a 0.00 15/ 3 PRM31 8 9 • - 0.00 b _ 0.00 - - 10 11 - • 0.00 c _ On • - 12 13 MEF 1 SWAMP FAN 15/ 3 0.00 a 0.00 301 3 SUB MAIN 14 15 - - 0.00 b _ 0.00 - - 16 17 - - 0.00 c 0.00 - 18 19 PRWE-12 20V 3 0.00 a 0A0 1001 3 HDB SECTION 2 20 21 - - 0.00 b 0.00 • 22 23 - • 0.00 c _ 0.00 - 24 25 LDB SEC 175KVA XFMR 125/ 3 4.41 a 0.00 225/ 3 PRIS-7 26 27 - - 2.96 b 0.00 •- 28 29 - • 4.11 c 0.00 - • 30 31 DOWNLITES 201 1 0.00 a 0.00 201 1 COVE LTG 32 33 DOWNLITES 20/ 1 0.00 b 0.00 201 1 COVE LTG 34 35 DOWNLITES 20/ 1 0.86 c 0.00 201 1 COVE LTG 36 37 SPACE 20/ 1 0.00 a 0.00 201 1 SPACE 38 39 SPACE 201 1 0.00 b 0.00 2011 SPACE 40 41 SPACE 20/ 1 0.00 c _ 0.00 20/ 1 SPACE 42 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. NOTES SHOWN. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT MOTOR 2.26 kVA 125% 0.36 kVA 50%>10kVA 0.00 kVA 100% 0.00 kVA 125% 0.00 kVA 100% 15.72 kVA 100% 0.00 kVA 0% 2.83 kVA 0.36 kVA 0.00 kVA 0.00 kVA 0.00 kVA 15.72 kVA 0.00 kVA EXISTING CONDITION TOTAL 18.34 kVA 22.1 AMPS 18.91 kVA 22.7 AMPS PANEL NAME: MAIN SWITCHBOARD LOCATION: ELECTRICAL RM FED FROM: UTILITY kAIC SYM 2000 AMP PANEL SCHEDULE 480Y/277 VOLT SECTION: 1 OF 1 3 PHASE, 4 WIRE FLOOR MOUNT SWBD MAIN FUSED SW 2000 AMP BUS CU BUS MFGR: CAT # 100% NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB kVA P H kVA CB CIRCUIT DESCRIPTION Ckt No. AMPS POL AMPS POL 1 PNL LHD 2001 3 0.00 a 0.00 4001 3 PNL PA 2 • 0.00 b 0.00 - - - 0.00 c 0.00 - • 3 PNL HJB 4001 3 0.00 a 0.00 1001 3 PNL HGA 4 - OM b 0.00 - - 0.00 c 0.00 - - 5 PNL HHA 6001 3 0.00 a 0.00 4001 3 PNL HJA 6 - 0.00 b 0.00 - - • 0.00c 0.90 - - 7 PNL HDA 400/ 3 0.00 a 0.00 400/ 3 PNL HKA 8 - - 0.00 b 0.00 - - - 0.00 c 0.00 - - 9 PNL HHB 4001 3 0.00 a 0.00 600/ 3 PNL PB 10 - • 0.00 b 0.00 - - - 0.00 c 0.00 - - 11 PNL HDB "R 4001 3 5.08 a 0.00 12 - - 4.79 b 0.00 • - 4.88 c 0.00 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. NOTES LOAD. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT MOTOR 0.97 kVA 125% 0.36 kVA 50%>10kVA 0.00 kVA 100% 0.00 kVA 125% 0.00 kVA 100% 13.42 kVA 100% 0.00 kVA 0% 1.21 INA 0.36 kVA 0.00 kVA 0.00 kVA 0.00 kVA 13.42 kVA 0.00 kVA "' INDICATES REVISED TOTAL 14.75 kVA 17.7 AMPS 14.99 kVA 18.0 AMPS PANEL NAME: HDB SEC. 1 (REVISED) LOCATION: AC PENTHOUSE #7 (ROOF) FED FROM: MAIN SWITCHBOARD kAIC SYM 400 AMP PANEL SCHEDULE MFGR: 480Y1277 VOLT SECTION: 1 OF 1 CAT # 3 PHASE, 4 WIRE SURFACE MOUNT PNL MLO 400 AMP BUS CU BUS 100% NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB kVA P H kVA CB CIRCUIT DESCRIPTION Ckt No. AMPS POL AMPS POL 1 PR/H-24 15/ 3 0.00 a 0.00 151 3 PR/R-7 2 3 - - 0.00 b 0.00 - 4 5 - - 0.00 c 0.00 6 7 PRIR 7 151 3 0.00 a 0.00 151 3 PR/H31 8 9 - - 0A0 b 0.00 • - 10 11 - • 0.00 c 0.00 - • 12 13 MEF 1 SWAMP FAN 15/ 3 0.00 a 0.00 30l 3 SUB MIN 14 15 • - 0.00 b 0.00 •- 16 17 - - 0.00 c 0.00 - - 18 19 PRIE-12 201 3 0.00 a 0.00 1001 3 HDB SECTION 2 20 21 - - 0.00 b 0.00 • - 22 23 - - 0.00 c 0.00 - • 24 25 LDB SEC 175KVA XFMR R" 1251 3 3.08 a 0.00 2251 3 PR/S-7 26 27 - - 2.79 b 0.00 •- 26 29 - • 2.53 c 0.00 - - 30 31 DOWNLITES 201 1 0.00 a 0.00 201 1 COVE LTG 32 33 DOWNLITES 201 1 0.00 b 0.00 201 1 COVE LTG 34 35 DOWNLITES R" 201 1 0.35 c 0.00 201 1 COVE LTG 36 37 SPACE 20/ 1 0.00 a 0.00 201 1 SPACE 38 39 SPACE 20/ 1 0.00 b 0.00 201 1 SPACE 40 41 SPACE 20/ 1 0.00 c 0.00 201 1 SPACE 42 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. NOTES CIRCUIT. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT MOTOR 0.97 kVA 125% 0.36 kVA 50%>10kVA 0.00 kVA 100% 0.00 kVA 125% 0.00 kVA 100% 13.42 kVA 100% 0.00 kVA 0% 1.21 kVA 0.36 kVA 0.00 kVA 0.00 kVA 0.00 kVA 13.42 kVA 0.00 kVA "R INDICATES REVISED TOTAL 14.75 kVA 17.7 AMPS 14.99 kVA 18.0 AMPS ELl9O 889 SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA98188 1 BURGESS DESIGN INTERIORS • ARCHITECTURE Al rptoduel en 4 MENed-A parlay lights Rows! a 2017 Wood Harbinger gag loath Ave NE, Suite moo Bellevue. WA g8004 425.6x8.6000 woodhathingercom Profeeatonal seol No. Issue Dncdption Data REVIEW SET 09.18.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.18.19 City Electronic Stomp Location COMPLIANCE WITH; NcPA to - NEC I I.;: 2 L 2019 Cky cr TUAwih: 180I101HG CMShi,n• Drawn by MK Project Ma oger: RM Project No: 19.0188.00 ELECTRICAL SCHEDULES QWrol flag Is 24" x x. sore raise aoe.J.4 a NSW E.6.2 PANEL NAME: HDB SEC. 2 (EXIST) PANEL SCHEDULE MFGR: LOCATION: AC PENTHOUSE #7 (ROOF) 480Y1277 VOLT SECTION: 1 OF 1 CAT # FED FROM: HDB SEC. 1 3 PHASE, 4 WIRE SURFACE MOUNT PNL kAIC SYM 225 AMP MLO 225 AMP BUS CU BUS 100%NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB kVA P H kVA CB CIRCUIT DESCRIPTION Ckt No. AMPS POL AMPS POL 1 SEF-3 151 3 0.00 a 0.00 20! 1 EAST HALL CEILING CANS 2 3 • - 0.00 b 0.00 20/ 1 PC & TC SCONCE 4 5 • - 0.00 c 0.00 20/ 1 EMS OUTSIDE EAST W 6 7 EMS COVE STRIPS 20/ 1 0.00 a 0.00 151 3 SEF-4 8 9 EMS CANS 20/ 1 0.00 b 0.00 - - 10 11 EMS ARCH 20/ 1 0,00 c 0.00 - - 12 13 COMPACTOR LIGHT LIGHT BACK CORRIDOR 20/ 1 0.00 a 0.00 30/ 3 AIR DOOR 14 15 CDF-1 EMB SYSTEM 301 2 0.00 b 0.00 - 16 17 - - 0.00 c 0.00 18 19 SEF-2 15/ 3 0.00 a 0.00 151 3 SEF-1 20 21 - - 0.00 b 0.00 •- 22 23 • - 0.00 c 0.00 - - 24 25 SPF-1 151 3 0.00 a 0.00 15/ 3 SPF-3 26 27 - - 0.00 b 0.00 - - 28 29 - - 0.00 c 0.00 - - 30 31 SPF-2 15/ 3 0.00 a 0.00 15/ 3 UHE-1 32 33 - - 0.00 b 0.00 - - 34 35 - - 0.00 c 0.00 - - 36 37 UNIT HEATER 2 301 3 O,00 a 2.00 151 3 HWT STORAGE RM 38 39 - - 0.00 b 2.00 - - 40 41 - - 0.00 c 2.00 . - 42 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. NOTES SHOWN. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT 0.00 kVA 125% 0.00 kVA 0.00 kVA 50%>10kVA 0.00 kVA 0.00 kVA 100% 0.00 kVA MOTOR 0.00 kVA 125% 0.00 kVA 0.00 kVA 100% 0.00 kVA 6.00 kVA 100% 6,00 kVA 0.00 kVA 0% 0.00 kVA EXISTING CONDITION TOTAL 6.00 kVA 6.00 kVA 7.2 AMPS 7.2 AMPS PANEL NAME: LDB SEC.1 (EXIST) PANEL SCHEDULE MFGR: LOCATION: AC PENTHOUSE #7 (ROOF) 208Y/120 VOLT SECTION: 1 OF 1 CAT # FED FROM: HDB SEC. 1 3 PHASE, 4 WIRE SURFACE MOUNT PNL kAIC SYM 225 AMP MLO 225 AMP BUS CU BUS 100% NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB kVA P H WA CB CIRCUIT DESCRIPTION Ckt No, AMPS POL AMPS POL 1 TOILET RM LTS HEATERS 201 1 1.40 a 0,00 201 1 EXHAUST FAN RR 2 3 SIGN LIGHT 201 1 0.00 b 0.00 20(1 SPARE 4 5 TOILET RM HEAT 201 1 0.00 c 0.00 20! 1 MECH RM LTS CONTACTOR COIL 6 7 7? 201 1 0.00 a _ 0.00 20! 1 MECH RM RECEPT 8 9 H-1BCIRC PUMP 301 1 0.00 b 0.00 15/ 1 E-9 EXH FAN 10 11 H-23CIRCPUMP 3011 0.00 c 0.00 2011 MECHRMLTSENT#5 12 13 BOILER CONTROL 201 1 0.00 a 0.00 201 1 E-10 HEAT UNITS ENT #5 & #6 14 15 HIGH BAY LTS 20/ 1 0.00 b 0.00 201 1 HIGH BAY LTS 16 17 HIGH BAY LTS 20/ 1 OA0 c 0.00 20/ 1 HIGH BAY LTS 18 19 HIGH BAY LTS 201 1 0.00 a 0.00 201 1 NIGHT LIGHTS SKYLIGHT BY EAST ENTRY DOORS 20 21 HIGH BAY LTS 20! 1 0.00 b 0.00 201 1 HIGH BAY LTS 22 23 HIGH BAY LTS 201 1 0.00 c 0.00 201 1 CAN LIGHTS FRONT OF JCP 24 25 HIGH BAY LTS 20/ 1 0.00 a 0.00 201 1 HIGH BAY LTS 26 27 HIGH BAY LTS 201 1 0.00 b 0.00 20/ 1 CAN LIGHTS FRONT OF JCP 28 29 HIGH BAY LTS 201 1 0.00 c 0.00 201 1 HIGH BAY LTS 30 31 HIGH BAY LTS 20! 1 0.00 a 0.00 201 1 HIGH BAY LTS 32 33 HIGH BAY GLOBE LTS 201 1 0.00 b 0.00 20/ 1 HIGH BAY LTS 34 35 HIGH BAY LTS 201 1 0.00 c 0.00 20/ 1 HIGH BAY LTS 36 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. NOTES SHOWN. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT 1.40 kVA 125% 1.75 kVA 0.36 kVA 50%>10kVA 0.36 kVA 0.00 kVA 100% 0.00 kVA MOTOR 0.00 kVA 125% 0.00 kVA 0.00 kVA 100% 0.00 kVA 9.72 kVA 100% 9.72 kVA 0.00 kVA 0% 0.00 kVA EXISTING CONDITION TOTAL 11.48 kVA 11.83 kVA 31.9 AMPS 32.8 AMPS PANEL NAME: HDB SEC. 2 (REVISED) PANEL SCHEDULE MFGR: LOCATION: AC PENTHOUSE #7 (ROOF) 480Y/277 VOLT SECTION: 1 OF 1 CAT# FED FROM: HDB SEC.1 3 PHASE, 4 WIRE SURFACE MOUNT PNL kAIC SYM 225 AMP MLO 225 AMP BUS CU BUS 100% NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB kVA P H kVA CB CIRCUIT DESCRIPTION Ckt No. AMPS POL AMPS POL 1 SEF-3 15/ 3 0.00 a 0.00 201 1 EAST HALL CEILING CANS 2 3 • - 0.00 b 0.00 20! 1 PC & TC SCONCE 4 5 - • 0.00 c 0.00 201 1 EMS OUTSIDE EAST W 6 7 EMS COVE STRIPS 20/ 1 0.00 a 0.00 151 3 SEF-4 8 9 EMS CANS 201 1 0.00 b 0.00 - 10 11 EMS ARCH 20/ 1 0.00 c 0.00 - - 12 13 COMPACTOR LIGHT LIGHT BACK CORRIDOR 20/ 1 0.00 a 0.00 30! 3 AIR DOOR 14 15 CDF•1 EMB SYSTEM 30/ 2 0.00 b 0.00 - - 16 17 - - 0.00 c 0.00 - - 18 19 SEF-2 15/ 3 0.00 a 0.00 151 3 SEF-1 20 21 - - 0.00 b 0.00 - - 22 23 - - 0.00 c 0.00 - - 24 25 SPF-1 151 3 0.00 a 0.00 15/ 3 SPF-3 26 27 - • 0.00 b 0.00 - 28 29 - - 0,00 c 0.00 - - 30 31 SPF-2 15/ 3 0.00 a 0.00 15/ 3 UHE-1 32 33 • - 0.00 b 0.00 - - 34 35 - - 0.00 c 0.00 - - 36 37 UNIT HEATER 2 301 3 0.00 a 2.00 151 3 WH-1 JANITOR RM '" 38 39 - - 0.00 b 2.00 - - 40 41 - - 0.00 c 2,00 • - 42 LOAD SUM CONN LOAD FACTOR CALC LOAD 1, NOTES CIRCUIT. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT 0.00 kVA 125% 0.00 kVA 0.00 kVA 50%>10kVA 0.00 kVA 0.00 kVA 100% 0.00 kVA MOTOR 0.00 kVA 125% 0.00 kVA 0.00 kVA 100% 0.00 kVA 6.00 kVA 100% 6.00 kVA 0.00 kVA 0% 0.00 kVA ' INDICATES REVISED TOTAL 6.00 kVA 6.00 kVA 72 AMPS 7.2 AMPS PANEL NAME: LDB SEC.1 (REVISED) PANEL SCHEDULE MFGR: LOCATION: AC PENTHOUSE #7 (ROOF) 208Y/120 VOLT SECTION: 1 OF 1 CAT # FED FROM: HDB SEC. 1 3 PHASE, 4 WIRE SURFACE MOUNT PNL kAIC SYM 225 AMP MLO 225 AMP BUS CU BUS 100% NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB kVA P H kVA CB CIRCUIT DESCRIPTION Ckt No, AMPS POL AMPS POL 1 TOILET RM LTS HEATERS ' 20/ 1 0.62 a 0.00 20! 1 EXHAUST FAN RR 2 3 SIGN LIGHT 201 1 0.00 b 0.00 20! 1 SPARE 4 5 TOILET RM HEAT 20! 1 0.00 c 0.00 20/ 1 MECH RM LTS CONTACTOR COIL 6 7 ?? 20! 1 0.00 a 0.00 20/ 1 MECH RM RECEPT 8 9 H-1B CIRC PUMP 301 1 0.00 b 0.00 151 1 E•9 EXH FAN 10 11 H-23 CIRC PUMP 301 1 0.00 c 0.00 20/ 1 MECH RM LTS ENT #5 & #6 12 13 BOILER CONTROL 201 1 0.00 a 0.00 20! 1 E-1O HEAT UNITS ENT #5 & #6 14 15 HIGH BAY LTS 201 1 0.00 b 0.00 201 1 HIGH BAY LTS 16 17 HIGH BAY LTS 201 1 0.00 c 0.00 20! 1 HIGH BAY LTS 18 19 HIGH BAY LTS 20! 1 0.00 a 0.00 20/ 1 NIGHT LIGHTS SKYLIGHT BY EAST ENTRY DOORS 20 21 HIGH BAY LTS 20/ 1 0.00 b 0.00 201 1 HIGH BAY LTS 22 23 HIGH BAY LTS 20! 1 0,00 c 0.00 20! 1 CAN LIGHTS FRONT OF JCP 24 25 HIGH BAY LTS 20/ 1 0.00 a 0.00 201 1 HIGH BAY LTS 26 27 HIGH BAY LTS 20/ 1 0.00 b 0,00 20! 1 CAN LIGHTS FRONT OF JCP 28 29 HIGH BAY LTS 20/ 1 0.00 c 0.00 20/ 1 _ HIGH BAY LTS 30 31 HIGH BAY LTS 20/ 1 0.00 a 0.00 20/ 1 HIGH BAY LTS 32 33 HIGH BAY GLOBE LTS 20/ 1 0.00 b 0.00 20/ 1 HIGH BAY LTS 34 35 HIGH BAY LTS 20/ 1 0.00 c 0.00 201 1 HIGH BAY ITS 36 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. NOTES CIRCUIT. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT 0.62 kVA 125% 0.77 kVA 0.36 kVA 50%>10kVA 0.36 kVA 0.00 kVA 100% 0.00 kVA MOTOR 0.00 kVA 125% 0.00 kVA 0.00 kVA 100% 0.00 kVA 1.42 kVA 100% 7.42 kVA 0.00 kVA 0% 0.00 kVA "' INDICATES REVISED TOTAL 8.40 kVA 8.55 kVA 23.3 AMPS 23.7 AMPS SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 B BURGESS DESIGN iNTERIOR5 • ARCHITECTURE NI reproduction & hbkctud property rights weaned c 2017 Wood Harbinger 929 1o8th Ave NE, Suite woo Bellevue, WA 98°04 425.628.6000 woodharbmger.com Professional seal No. issue Description Date REVIEW SET 09.16.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.16.19 City Electronic Stamp Location -fI-Nti FOET:COMPLIANCE MPG• Hsi 21 2019 i C'ty M'ukwry LBUILDING DNISiON Drown by: MK Project Manager: RM Project No: 19.0168.00 ELECTRICAL SCHEDULES angkal *nftg r 24• s 36-. Seale India omarirdy If reduced E.6.3 PANEL NAME: LDB SEC. 2 (EXIST) PANEL SCHEDULE MFGR: LOCATION: AC PENTHOUSE #7 (ROOF) 208Y/120 VOLT SECTION: 1 OF 1 CAT # FED FROM: LDB SEC. 1 3 PHASE, 4 WIRE SURFACE MOUNT PNL kAIC SYM 225 AMP MLO 225 AMP BUS CU BUS 100% NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB kVA P H kVA CB CIRCUIT DESCRIPTION Ckt No. AMPS POL AMPS POL 37 FA SYSTEM 20! 1 0.00 a 0.00 30! 1 PLANTER RECEPT MI52 38 39 MALL CEIL. RECEPT 201 1 0.00 b 0.00 20! 1 WALKWAY LTS 40 41 SEASONAL ROOF RECEPT 201 1 0.00 c 0.00 20! 1 WALKWAY LTS 42 43 SEASONAL ROOF RECEPT 20/ 1 OAO a 0.00 20/ 1 SIGN LIGHT 44 45 SEASONAL ROOF RECEPT 20/ 1 0.00 b 0.00 20! 1 PENNY 46 47 RECEPT IN MALL NE 201 1 0.00 c 0.00 20/ 1 CONTROL POWER FA 48 49 RECEPT IN MALL NE 201 1 0.00 a 0.00 20/ 1 ?? 50 51 RECEPT IN MALL NE 20! 1 0.00 b 0.00 20! 1 RECEPT IN NE CORR HALL 52 53 SMOKE DETECTOR JSC 20! 1 0.00 c 0.00 40/ 2 RECEPT IN NE CORR HALL 54 55 LIGHTING CONTROL CIRC 2011 0.00 a 0.00 - - 56 57 PLANTER RECEPT M158 201 1 0.00 b 0.00 20/ 1 PLANTER RECEPT 58 59 PLANTER RECEPT 20! 1 0.00 c 0.00 20! 1 PLANTER RECEPT 60 61 PLANTER RECEPT 20! 1 0.00 a 0.00 100/ 3 #9 COMPACTOR 62 63 TOILET RM HW HEAT 201 2 0.00 b 0.00 • - 64 65 - - 0.00 c 0.00 - - 66 LOAD SUM CONN LOAD FACTOR CALC LOAD 1, NOTES SHOWN. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT 0.00 kVA 125% 0,00 kVA 0.36 kVA 50%>10kVA 0.36 kVA 0.00 kVA 100% 0.00 kVA MOTOR 0.00 kVA 125% 0.00 kVA 0.00 kVA 100% 0.00 kVA 9.72 kVA 100% 9.72 kVA 0.00 kVA 0% 0.00 kVA EXISTING CONDITION TOTAL 10.08 kVA 10.08 kVA 28.0 AMPS 28.0 AMPS PANEL NAME: LDB SEC. 3 (EXIST) PANEL SCHEDULE MFGR: LOCATION: AC PENTHOUSE #7 (ROOF) 208Y1120 VOLT SECTION: 1 OF 1 CAT# FED FROM: LDB SEC. 1 3 PHASE, 4 WIRE SURFACE MOUNT PNL kAIC SYM 100 AMP MLO 100 AMP BUS CU BUS 100%NEUTRAL CKT, NO. CIRCUIT DESCRIPTION CB kVA P H WA CB CIRCUIT DESCRIPTION Ckt No. AMPS POL AMPS POL 1 JC PENNEY POP MACHINE OUTLET, KARAOKE BOX 201 2 0.00 a 0.40 201 1 SINK FLUSHERSITRANS 2 3 - - 0.00 b 0.00 20/1 RECEPTJANITORIE•ROO 4 5 SPARE 20! 1 0.00 c 0.80 20f 1 URINAL FLUSHERS! TRANS 6 1 HWT 20! 1 2.00 a 0.36 201 1 RECEPT BATH HALL 8 9 HAND DRYER 30! 1 1.40 b 0.46 201 1 DRINKING FOUNTAIN 10 11 HAND DRYER 30! 1 1.40 c 0.46 20/ 1 DRINKING FOUNTAIN 12 13 HAND DRYER 301 1 'AO a 0.00 201 1 RECEPT & SOFFIT READER 14 15 HAND DRYER 301 1 1.40 b 0.00 201 1 RECEPT MAIN ENTRY 16 17 PLUGS UPPER SOFFIT 201 1 0.00 c 0.00 201 1 RECEPT MAIN ENTRY 18 19 SIGN LIGHT 20/ 1 0.00 a 0.00 201 1 RECEPT MALL SOFFIT 20 21 TREE PITS LIGHTS 20! 1 0.00 b 0.00 20! 1 RECEPT MALL SOFFIT 22 23 TREE PITS RECEPT 20! 1 0.00 c 0.00 201 1 RECEPT SIGN MALL 24 25 MALL DIRECTORIES NE CORR. 20! 1 0.00 a _ 0,00 601 3 C DOCK COMPACTORS 26 27 RECEPT COMPACTOR 20! 1 0.00 b 0.00 - - 28 29 TREE PITS RECEPT 201 1 0.00 c 0.00 - - 30 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. NOTES SHOWN. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT 0.00 kVA 125% 0.00 kVA 0.36 kVA 50%>10kVA 0.36 kVA 0.00 kVA 100% 0.00 kVA MOTOR 0.00 kVA 125% 0.00 kVA OR kVA 100% 0.00 kVA 9.72 kVA 100% 9.72 kVA 0.00 kVA 0% 0.00 kVA EXISTING CONDITION TOTAL 10.08 kVA 10.08 WA 28.0 AMPS 28.0 AMPS PANEL NAME: LDB SEC. 2 (REVISED) PANEL SCHEDULE MFGR: LOCATION: AC PENTHOUSE #7 (ROOF) 208Y1120 VOLT SECTION: 1 OF 1 CAT # FED FROM: LDB SEC. 1 3 PHASE, 4 WIRE SURFACE MOUNT PNL kAIC SYM 225 AMP MLO 225 AMP BUS CUBUS 100% NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB kVA P H kVA CB CIRCUIT DESCRIPTION Ckt No. AMPS POL AMPS POL 37 FA SYSTEM 20/ 1 0.00 a 0.00 301 1 PLANTER RECEPT IW52 38 39 MALL CEIL. RECEPT 20/ 1 0.00 b 0.00 20/ 1 WALKWAY LTS 40 41 SEASONAL ROOF RECEPT 20/ 1 0.00 c 0.00 201 1 WALKWAY LTS 42 43 SEASONAL ROOF RECEPT 20/ 1 0.00 a 0.00 201 1 SIGN LIGHT 44 45 SEASONAL ROOF RECEPT 20/ 1 0.00 b 0.00 20! 1 PENNY 46 47 RECEPT IN MALL NE 20/ 1 0.00 c 0.00 201 1 CONTROL POWER FA 48 49 RECEPT IN MALL NE 20/ 1 0.00 a 0.00 201 1 ?? 50 51 RECEPT IN MALL NE 201 1 0.00 b 0.00 20! 1 RECEPT IN NE CORR HALL 52 53 SMOKE DETECTOR JSC 201 1 0.00 c 0.00 40! 2 RECEPT IN NE CORR HALL 54 55 LIGHTING CONTROL CIRC 20/ 1 0.00 a 0.00 - - 56 57 PLANTER RECEPT W58 20! 1 0.00 b 0.00 20! 1 PLANTER RECEPT 58 59 PLANTER RECEPT 20/ 1 0.00 c O.00 20! 1 PLANTER RECEPT 60 61 PLANTER RECEPT 20/ 1 0.00 a 0.00 100/ 3 #9 COMPACTOR 62 63 TOILET RM HW HEAT 201 2 0.00 b 0.00 - - 64 65 • - 0.00 c OM • - 66 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. NOTES ONLY. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT 0.00 kVA 125% 0.00 kVA 0.36 kVA 50%>10kVA 0.36 kVA 0.00 kVA 100% 0.00 kVA MOTOR 0.00 kVA 125% 0.00 kVA 0.00 kVA 100% 0.00 kVA 7.42 kVA 100% 7.42 kVA 0.00 kVA 0% 0.00 kVA PANEL FOR REFERENCE TOTAL 7.78 kVA 7.78 kVA 21.6 AMPS 21.6 AMPS PANEL NAME: LDB SEC. 3 (REVISED) PANEL SCHEDULE MFGR: LOCATION: AC PENTHOUSE #7 (ROOF) 20817120 VOLT SECTION: 1 OF 1 CAT # FED FROM: LDB SEC. 1 3 PHASE, 4 WIRE SURFACE MOUNT PNL 'LAIC SYM 100 AMP MLO 100 AMP BUS CU BUS 100% NEUTRAL CKT. NO. CIRCUIT DESCRIPTION CB WA P H kVA CB CIRCUIT DESCRIPTION (act No. AMPS POL AMPS I POL 1 JC PENNEY POP MACHINE OUTLET, KARAOKE BOX 20! 2 0.00 a 0.40 20/ 1 SINK & SOAP DISPENSERS "' 2 3 - • 0.00 b 0.00 20/ 1 RECEPT JANITORIE-R00 4 5 SPARE 201 1 0.00 c 0.80 20! 1 P2, P4 M" 6 7 SPARE ' 20! 1 0.00 a 0.36 201 1 RECEPT BATH HALL 8 9 HAND DRYER "' NOTE 2 20/ 1 1.44 b 0.46 201 1 P-10 " 10 11 HAND DRYER "' NOTE 2 201 1 1.44 c 0.00 20/ 1 SPARE "' 12 13 HAND DRYER *" NOTE 2 20! 1 1.44 a 0.00 20/ 1 RECEPT & SOFFIT READER 14 15 HAND DRYER "' NOTE 2 20! 1 1.44 b 0.00 20! 1 RECEPT MAIN ENTRY 16 17 PLUGS UPPER SOFFIT 201 1 0.00 c 0.00 20/ 1 RECEPT MAIN ENTRY 18 19 SIGN LIGHT 20! 1 0.00 a 0.00 20! 1 RECEPT MALL SOFFIT 20 21 TREE PITS LIGHTS 201 1 0.00 b 0.00 20! 1 RECEPT MALL SOFFIT 22 23 TREE PITS RECEPT 201 1 0.00 c 0.00 20! 1 RECEPT SIGN MALL 24 25 MALL DIRECTORIES NE CORR. 201 1 0.00 a 0.00 60! 3 C DOCK COMPACTORS 26 27 29 RECEPT COMPACTOR 2011 0.00 b 0.00 - - 28 TREE PITS RECEPT 201 1 0.00 c 0.00 • - 30 LOAD SUM CONN LOAD FACTOR CALC LOAD 1. 2. NOTES CIRCUIT. NEW 20A BREAKER. LIGHTING RECEPTACLES ALL MOTORS LRGST KITCHEN MISCELLANEOUS NON -COINCIDENT 0.00 kVA 125% 0,00 kVA 0.36 kVA 50%>10kVA 0.36 kVA 0.00 kVA 100% 0.00 kVA MOTOR OEOO kVA 125% 0.00 kVA 0.00 kVA 100% 0.00 kVA 7.42 kVA 100% 7.42 kVA 0.00 kVA 0% 0.00 kVA '" INDICATES REVISED REMOVE AND PROVIDE TOTAL 7.78 kVA 7.78 kVA 21.6 AMPS 21.6 AMPS SEAFOOD CITY RESTROOMS WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 w UNIBAIL-RODAMCO-WESTFIELD URW WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL TUKWILA, WA 98188 B BURGESS DESIGN INIERIORS • ACIITCTUAE All reproduction & trteseelual properly rt rh reared c 2017 Wood Harbinger 929 1o8th Ave NE, Suite moo Bellevue, WA 98004 425.628.6000 woodharbinger.com Professional seal No. Issue Description Date REVIEW SET 09.18.19 PRICING SET 10.04.19 PRICING SET REVISION 1 10.11.19 PERMIT SET 10.18.19 City Electronic Stomp Location REVIEWED FO1 1 NF I COMPLIPA 70 AqNCE \M T l+l - NE?G 1 I l City al E Tukwila L194 98s I BUILDING DIVISION , O.' TUKVV;LA R.V. 2.. ZOk1 Drawn by MK Project Manager. RM Project No: 19.0188.00 ELECTRICAL SCHEDULES M¢d &eesq Y 24• R 3e. So* wain aooardingy r retold OCT 29ti E.6.4