HomeMy WebLinkAboutPermit EL19-0899 - FIRE STATION 52 / NEW BUILDING - SERVICE, LIGHTING, HVAC, GENERATOR AND POWERFIRE STATION 52 - BUILDING 15447 65TH AVE S Apn: 3597000320 FINALED 01/12/2021 ELI 9-0899 Parcel No: Address: City of Tukwila a t of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 3597000320 Permit Number: EL19-0899 15447 65TH AVE S Project Name: FIRE STATION 52 BUILDING Issue Date: I/8/2020 Permit Expires On: 7/6/2820 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA CITY OF 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 SCOTT DRISCOLL l662ONORTH RD'BOTMELL,WA, 98012 PACIFIC COAST ELECT CONTR INC l66ZONORTH ROAD 'BOTHELL,WA, 980ZI'S9O8 PA[|F|[E077xxA ''' Phone: (206) 919-2042 Phone: (425) 741-2700 Expiration Date: 7/8/2021 DESCRIPTION OF WORK NEW SERVCE, LIGHTING, HVAC, GENERATOR AND POWER FOR A NEW FIRE STATION Valuation of single family: $0.00 Valuation of mf/comm: $980\31230 Type of Work: NEW Fees Collected: $13,596/0 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: lnterriational Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: 2015 20152015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: 2017WA State Energy Code: 2017 2017 2015 Permit Center Authorized Signature: 4'��/'s, 44 I hearby certify that I have read and examined this permit and know the same to be true and correct. A]| provisions of law and ordinances governing this work wiU be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work, am authorized to sigr and obtain this development permit and agree to the conditions attached to this permit. ^ ^_ Signature: Print Name: 114 '�`~-/��J�c^// u Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: Alt electrical work shall be in accordance with NFPA 70 NEC, and requirements for electrical installations, Chapter 296-468 WAC and the Washington Cities Electrical Code, 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB , CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: it\ n Date Application Expires: S. —1 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 15447 65th Ave S Tukwila Tenant Name: Tukwila Fire Station 52 King Co Assessor's Tax No.: Suite Number: New Tenant: PROPERTY OWNER Name: Scott Driscoll Name: City of Tukwila Public Works Address: 1.6620 North RD Address: 6200 Southcenter Blvd Suite 100 City: Bothell City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Scott Driscoll Address: 16620 North Rd Address: 1.6620 North RD Phone: Fax: 425-741-2700 425-741-2600 City: Bothell WA State: Zip: 98012 Phone: 206-919-2042 Fax: 425-741-2600 Email: sdriscollancec.com Floor: EI Yes 0 ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Pacific Coast Electrical Contractors Address: 16620 North Rd City: Bothell State: WA Zip: 98012 Phone: Fax: 425-741-2700 425-741-2600 Conn Reg No.: Exp Date: PACIFCE077MA 06/30/2020 Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 980,312.30 Scope of Work (please provide detailed information): New Fire Station. New Service. lighting. HVAC. Generator. power. Will service be altered? ED Yes No Adding more than 50 amps? ED Yes 0 No Type of Use: Type ofwork: 51 New 0 Service Change El Remodel El Low Voltage 0 Fire Alarm 0 Telecommunication 0 Addition El Generator Property Served by: 0 Puget Sound Energy 11 Seattle City Light WAPermit Center \Applications -Handouts \ Permit Applications \PDFstElectrical Permit Application Revised -1 7- I 9.docis El Tenant Improvement 0 Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $180.00 (including an attached garage) • Garages, pools, spas and outbuildings $120.00 ea ❑ Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $120.00 (no added/altered circuits) ❑ Service change with added/altered circuits $100.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $60.00 (up to 5 circuits) ❑ Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea ❑ Meter/mast repair $80.00 ❑ Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $90.00 ❑ Manufactured/mobile home service $100.00 (excluding garage or outbuilding) ❑ Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% 1`ECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature;. Print Name: Scott Driscoll Mailing Address: 16620 North RD W:Tennit Center\Applications-Handouts\Permit Applications NPBF'ssEtectrical Permit Application Revised t -t 7-I9.docx Date: Day Telephone: 206-919-2042 Bothell City WA State 98012 Zip Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $10,981.71 EL19-0899 Address: 15447 65TH AVE S April: 3597000320 $ 0,981.71 ELECTRICAL $10,458.77 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $10,458.77 TECHNOLOGY FEE $522.94 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R19592 R000.322.900.04.00 0.00 $522.94 $10,981.71 Date Paid: Wednesday, January 08, 2020 Paid By: CITY OF TUKWILA Pay Method: CITY ACCOUNT 90830405.1000.107 3 Printed: Wednesday, January 08, 2020 10:41 AM 1 of 1 Y5TEM5 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,614.69 EL19-0899 Address: 15447 65TH AVE S Apn: 3597000320 $2,614.69 ELECTRICAL PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R19110 R000.345.832.00.00 0.00 $2,614.69 $2,614.69 $2,614.69 Date Paid: Tuesday, November 19, 2019 Paid By: CITY OF TUKWILA Pay Method: ACCOUNT Printed: Tuesday, November 19, 2019 1:58 PM 1 of 1 CRWYSTEMS Permit Number: EL19-0899 Permit Inspections City of Tukwila Applied: 11/1/2019 Approved: 1/4/2020 Issued: 1/8/2020 Finaled: 1/12/2021 Status: FINALED Parent Permit: Parent Project: Details: Description: FIRE STATION 52 - BUILDING Site Address: 15447 65TH AVE S City, State Zip Code:TUKWILA, WA 98188 Applicant: FIRE STATION 52 - BUILDING Owner: TUKWILA CITY OF Contractor: PACIFIC COAST ELECT CONTR INC NEW SERVICE, LIGHTING, HVAC, GENERATOR AND POWER FOR A NEW FIRE STATION CV INS ECTIO S SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS ROUGH -IN ELECTRICAL Jim Benner Notes: UNDERGROUND SLAB Jim Benner Notes: UNDERGROUND PARTIAL 1/17/2020 Any 1/17/2020 SLAB Jim Benner APPROVAL eTRAKiT Inspection Request Notes: 1/16/2020 1:51 PM Scott Driscoll Contact Name: Mit Site Address: 15447 65TH AVE 5 Phone: 4257412700 e -Mail: sdriscoll@pcec.com 1/16/2020 1:53 PM Scott Driscoll Contact Name: Mitch Moore Site Address: 15447 65TH AVE S Phone: 2537929428 e -Mail: sdriscoll@pcec.com PARTIAL APPROVAL/#1 O.K. -2x4" LV SERVICE CONDUITS S.W. PARTIAL APPROVAL/#1 O.K. -2x4" LV SERVICE CONDUITS S.W. Printed: Thursday, 14 October, 2021 1 of 5 SUPERION Permit linspections City of Tukwila 1/27/2020 Any 1/27/2020 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL eTRAKiT Inspection Request Notes: 1/24/2020 12:14 PM Scott Driscoll 2nd Floor Slab inspections, (6) Floor boxes and Conduit Sleeves through deck Contact Name: Mitch Moore Site Address: 15447 65TH AVE 5 Phone: 2537929428 e -Mail: sdriscoll@pcec.com PARTIAL APPROVAL/#2 O.K. -L2 SLAB CONDUITS AND BOXES UNDERGROUND PARTIAL 2/6/2020 Any 2/6/2020 Jim Benner eTRAKiT Inspection Request SLAB APPROVAL Notes: 2/5/2020 3:08 PM Scott Driscoll Generator under ground conduit South end of site Contact Name: Mitch Moore Site Address: 15447 65TH AVE S Phone: 2537929428 e -Mail: sdriscoll@pcec.com PARTIAL APPROVAL/#3 O.K. -CONDUITS AT GEN. PAD ROUGH -IN PARTIAL 4/2/2020 Any 4/2/2020 ELECTRICAL Jim Benner APPROVAL eTRAKiT Inspection Request Notes: 4/1/2020 7:21 AM Scott Driscoll Contact Name: Mitch Site Address: 15447 65TH AVE 5 Phone: 4257412700 e -Mail: sdriscoll@pcec.com 4/1/2020 7:22 AM Scott Driscoll Exterior wall cover 1st and 2nd floor Contact Name: Mitch Moore Site Address: 15447 65TH AVE 5 Phone: 2537929428 e -Mail: sdriscoll@pcec.com PARTIAL APPROVAL/#4 O.K. -ALL WALLS t2 -EXTERIOR WALLS AND 8ft WALLS L1 PARTIAL APPROVAL/#4 O.K. -ALL WALLS 1_2 -EXTERIOR WALLS AND 8ft WALLS Ll Printed: Thursday, 14 October, 2021 2 of 5 r1 SUPERION Permit Inspections City of Tukwila 5/14/2020 AM 5/14/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 331354 Notes: PARTIAL APPROVAL/#5 O.K. -ALL WALLS Li & 2 SOUTH OF APP. BAY -HARDLIDS SAME EXCEPT STAIRWELLS PARTIAL APPROVAL/#5 O.K. -ALL WALLS L1 & 2 SOUTH OF APP. BAY -HARDLIDS SAME EXCEPT STAIRWELLS 6/9/2020 6/9/2020 ELECTRICAL FINAL Jim Benner NOT APPROVED Notes: CORRECTIONS/ #6 -MAX OCPD TO BE INSTALLED ON LINE SIDE OF BRANCH CIRCUIT CONDUCTORS FOR RTUs. -IN LINE EXHAUST FANS GFCI RESET TO BE READILY ACCESSIBLE 6/18/2020 AM 6/18/2020 I ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 55699 Notes: PARTIAL APPROVAL/#7 O.K. -WALL COVER APP BAY NORTH WALL -2nd FLOOR W. HARD LIDS AND SOFFITS PARTIAL APPROVAL/#7 O.K. -WALL COVER APP BAY NORTH WALL -2nd FLOOR W. HARD LIDS AND SOFFITS 6/23/2020 AM 6/23/2020 SERVICE Jim Benner PARTIAL APPROVAL 132874 Notes: PARTIAL APPROVAL/#8 O.K. -ENERGIZE MDP -ATS FEEDER TERMS PARTIAL APPROVAL/#8 O.K. -ENERGIZE MDP -ATS FEEDER TERMS 6/23/2020 6/23/2020 ROUGH IN ELECTRICAL Jim Benner NOT APPROVED Notes: CORRECTION/ #8 -WOOD SLAT CEILING 15 NOT ACCESSIBLE. 1 BOXES ABOVE TO BE RLOCATED CORRECTION/ #8 -WOOD SLAT CEILING IS NOT ACCESSIBLE. J BOXES ABOVE TO BE RLOCATED 6/25/2020 AM 6/25/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 12050 Notes: PARTIAL APPROVAL/#9 O.K. -L2 STAIR EAST HARD LID PARTIAL APPROVAL/#9 O.K. -L2 STAIR EAST HARD LID Printed: Thursday, 14 October, 2021 3 of 5 i4 SUPERION Permit Inspections City of Tukwila 6/30/2020 AM 6/30/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 414454 Notes: PARTIAL APPROVAL/#10 O.K. -ALL WALLS AND HARDLIDS COMPLETE PARTIAL APPROVAL/#10 O.K. -ALL WALLS AND HARDLIDS COMPLETE 7/22/2020 AM 7/22/2020 ROUGH -IN Jim Benner PARTIAL 431539 ELECTRICAL APPROVAL Notes: PARTIAL APPROVAL/#11 O.K. -APP BAY EXT. SOFFIT EAST PARTIAL APPROVAL/#11 O.K. -APP BAY EXT. SOFFIT EAST 8/13/2020 AM 8/13/2020 SERVICE Jim Benner 1 r PARTIAL APPROVAL 242149 Notes: PARTIAL APPROVAL/#12 O.K. -MBPE, PANELS A, 8, C -ELEVATOR PANEL AND DISCO PARTIAL APPROVAL/#12 O.K. -MBPE, PANELS A, B, C -ELEVATOR PANEL AND DISCO 8/13/2020 AM 8/13/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 224551 Notes: PARTIAL APPROVAL/#12 O.K. -T BAR CEILINGS L2 8/14/2020 AM 8/14/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 32310 Notes: PARTIAL APPROVAL/#13 O.K. -L1 CORRIDOR CEILINGS 8/14/2020 8/14/2020 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL Notes: PARTIAL APPROVAL/#13 O.K. -CONCRETE BOLLARDS & BENCHES PARTIAL APPROVAL/#13 O.K. -CONCRETE BOLLARDS & BENCHES 8/25/2020 AM 8/25/2020 SERVICE Jim Benner APPROVED 593297 Notes: Cancelation confirmation Number: 574097; APPROVED/ #13 O.K. -ATSs -MTS -GENERATOR -SERVICE COMPLETE Printed: Thursday, 14 October, 2021 4 of 5 S..'E R ON Permit Inspections City of Tukwila APPROVED/ #13 O.K. -ATSs -MTS -GENERATOR -SERVICE COMPLETE 12/11/2020 AM 12/11/2020 ELECTRICAL FINAL Jim Benner NOT APPROVED Derek - 206-484-2984 - 7AM inspection Notes: CORRECTIONS/ #14 -LAUNDRY ROOM RECEPS ALL REQUIRE GFCI. RESET TO BE READILY ACCESSIBLE. -APP BAY STORAGE N.E. GFCI PROTECTION REQ'D WITHIN6OF SINK. -PANEL M SCHEDULES NOT ACCURATE. -GFCIs AT WATER FOUNTAINS TO BE READILY ACCESSIBLE, -SPARKGUARDS/SPACERS IN WORKOUT ROOM MIRROR. -GFCI DISPOSAL. -GFCI FOR DISH/DISP LUNCH ROOM. -GROUND FLAG POLE. 12/29/2020 AM 12/29/2020 ELECTRICAL FINAL Jim Benner NOT APPROVED Nathan - 360-421-4309 Call 15 Min ahead Notes: CORRECTIONS/ #15 -LAUNDRY GFCIs NEED TO BE READILY ACCESSIBLE AND ALL RECEPS TO BE GFCI. -BREAKROOM DISWASHER RECEP. TO BE GFCI -MOUNT ROOFTOP RECEP. BOXES. -ROOF CONDENSORS REQUIRE LABELS TO MATCH DISCOS. -ALL OTHER CORRECTIONS MADE 1/12/2021 AM 1/12/2021 ELECTRICAL FINAL Jim Benner APPROVED Nathan - 360-421-4309 Call 15 Min ahead Notes: APPROVED/ #16 CORRECTIONS MADE O.K. -FINAL Printed: Thursday, 14 October, 2021 5 of 5 rk SUPERION City of Tukwila Department of Community Development December 02, 2019 SCOTT DRISCOLL 16620 NORTH RD BOTHELL, WA 98012 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL19-0899 FIRE STATION 52 - BUILDING - 15447 65 AVE S Dear SCOTT DRISCOLL, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each depai talent must be addressed at the same time and reflected on your drawings. 1 have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. • CORRECTIONS/ #1 1). SHEET E100 MDP TO BE RATED 1200 AMP MINIMUM 2). SHEET E100 EQUIPMENT GROUNDING CONDUCTORS TO BE SIZED ACCORDING TO TABLE 250.122 BASED ON THE SIZE OF THE OCPD AHEAD. 3). SHEET E100 SUPPLY SIDE BONDING JUMPERS ON UNPROTECTED CONDUCTORS TO BE SIZED PER 250.102 TABLE 250.102(C)(1) Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Frankie Alexander Permit Technician File No, ELI9-0899 63nn Condit -ardor Rmilow-yrd Cnito 341111) a Tydru,11.7 141,-rchi.ntrm OR RR a Phnri, 71.1F_A 1 _zx7n a 'MK A / 2(X ERM1T COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0899 DATE: 11/01/19 PROJECT NAME: FIRE STATION 52 - BUILDING SITE ADDRESS: 15447 65 AVE S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Pennit Issued after Pei, lit Issued DEPARTMENTS: Bui ding Division COPc 11416\ Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/05/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DA 1E: 12/03/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ht Fire 0 Ping PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0899 DATE: 12/11/19 PROJECT NAME: FIRE STATION 52 - BUILDING SITE ADDRESS: 15447 65 AVE S Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building ivision Public Works Fire Prevention Structural Planning Division Permit Coordinator IN PRELIMINARY REVIEW: Not Applicable fl (no approval/review required) REVIEWER'S INITIALS: DATE: 12/12/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 01/09/20 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: hup://www .Tukwi I aWA .gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: December 9, 2019 Plan Check/Permit Number: EL19-0899 El] Response to Incomplete Letter # 11 Response to Correction Letter # 1 • Revision # after Permit is Issued [l] Revision requested by a City Building Inspector or Plans Examiner E] Deferred Submittal # Project Name: Fire Station 52 - Building Project Address: 15447 65th Ave S RECEIVED CITY OF TUKWILA DEC 1 1 2019 PERMIT CENTER Contact Person: Rocxy Juan — TFWB Engineers Phone Number: (206) 285-7228 Summary of Revision: 1). Sheet E100: Clarified the rating of Panel MDP to 1200 Amp, 208Y/120 Volts, 3 -Phase, 4 -Wire 2) Sheet E100: Revised ground conductor sizes to meet NEC Table 250.122 3) Sheet E100: Revised and indicated bonding jumper ground conductor sizes to meet NEC 250.102 Table 250.102(C )(1). Sheet Number(s): "Cloud" or highlight all areas of revision including dateofrevisio Received at the City of Tukwila Pelinit Center by: —Entered in TRAKiT on - k O:\cd\TukwiIa FS #52 18-068\001 - ProjectWERMIT COMMENTS\Revision Submittal Form.doc . _ CJiIns (https://lni.wa.gov) Contractors PACIFIC COAST ELECT CONTR INC Owner or tradesperson Principals BLACKBURN, R DAVID, PRESIDENT ROTHERMEL, RICK A, VICE PRESIDENT BLACKBURN, R DAVID, AGENT Doing business as PACIFIC COAST ELECT CONTR INC WA UBI No. 601 473 603 16620 NORTH ROAD BOTHELL, WA 98012-5908 425-741-2700 SNOHOMISH County Business type Corporation Governing persons R DAVID BLACKBURN RICK ROTHERMEL; DALE M CAMPBELL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active Meets current requirements. License specialties GENERAL License no. PACIFCE077MA Effective — expiration 07/01/1993— 07/08/2021 Designatedadministrator. BLACKBURN, RALPH DAVID License type Electrical Administrator Bond Federated Mutual Ins Co Bond account no 6055752 Received by L&I 09/27/2017 Bond history No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active Meets current requirements. License no. BLACKR0066CE 54,000.00 Effective date 09/21/2017 Expiration date Until Canceled Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent