HomeMy WebLinkAboutPermit EL19-0949 - CELLNETIX - 3000A SERVICE, 200KW GENERATOR, POWER, LIGHTING, FIRE ALARM, TELE-DATACELLNETIX 12501 E MARGINAL WAY S FINALED 08/20/2020 ELI 9-0949 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206~431'3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 7345600580 Address: 12501 E MARGINAL WAY S Project Name: CELLNETIX ELECTRICAL PERMIT Permit Number: EL19-0949 Issue Date: I/24/2020, Permit Expires On: 7/22/2020 Owner: Name: INTERNATIONAL GATEWAY EAST Address: IZ2OlTUKVV|LA|NTRNTNL8L4TH , SEATTLE, WA, 98168 Contact Person: Name: JUSTIN TAYLOR Address: 1S323NE9OTH5T'REDMOND, WA, 98052 Contractor: PRECISION ELECTRIC GROLJP INC Address: 15323NE90THST,REDMOND, WA, 98052 License No; PRECIEG969PH Address: ''' Phone: (206) 948-9803 Phone: (425) 823-8600 Expiration Date: 10/9/2020 DESCRIPTION OF WORK: NEW 3000A SERVICE, NEW 200KW GENERATOR, POWER, LIGHTING, TELE -DATA, FIRE ALARM (UNDER SEPERATE Valuation of single family: $lOO Valuation of mf/comm: S500,000.00 Type of Work: TENANT IMP Fees Collected: $7,80713 Electrical Service Provded by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukw la: International Buiftiing Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National EIectric Code: WA Cities Electrical Code: WAC 296-46B: 2017WA State Energy Code: 20172017 2015 Permit Center Authorized Signature: Date: /�c(—l~��- 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or tocal laws regulaling construction o ' eperformance ofwork. 1 am authorized to sign and obtain this development permit and agree ions attached to this permit. Signature: Print Name: Date: /—E`(7020 This permit shall become null and void if the work is not commenced within 180 days for the date of ssuance, or if the work is suspended orabandoned for a period of 180 days from the Iast inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2O6)43O'935O 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE CITY OF TUK A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: (For ce use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 12501 E Marginal Way South, Tukwila, WA 98168 Tenant Name: Cellnetix King Co Assessor's Tax No.: Suite Number: New Tenant: PROPERTY OWNER Name: Justin Taylor Name: Sabey Corporation City: Redmond State: WA Zip: 98052 Address: 12201 Tukwila International Blvd 4th Floor Contr Reg No.: PRECIEG969PH Exp Date: 10/09/2020 City: Seattle State: WA Zip:98i68 CONTACT PERSON — person receiving all project communication Name: Justin Taylor Address: 15323 NE 90th Street City: Redmond State: WA Zip: 98052 Address: 15323 NE 90th Street Contr Reg No.: PRECIEG969PH Exp Date: 10/09/2020 Tukwila Business License No.; BUS -0993459 City: Redmond State: WA Zip: 98052 Phone: 206-948-9803 Fax: 425-823-8655 Email: justint@pegiinc.com Floor: E] Yes El ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Precision Electric Group Inc Address: 15323 NE 90th Street City: Redmond State: WA Zip: 98052 Phone: 206-948-9803 Fax: 425-823-8655 Contr Reg No.: PRECIEG969PH Exp Date: 10/09/2020 Tukwila Business License No.; BUS -0993459 Valuation of Project (contractor's bid price): $ 500,000.00 Scope of Work (please provide detailed information): New 3000A Service, New 200kW Generator, Power, Lighting, Tele -Data, Fire Alarm (Under Separate Permit) Will service be altered? III Yes El No Adding more than 50 amps? E] Yes El No Type of Use: Type of work: 0 New D Addition 0 Service Change 0 Remodel El Tenant Improvement 0 Low Voltage D Generator 0 Fire Alarm El Telecommunication 0 Temporary Service Property Served by: El Puget Sound Energy E Seattle City Light 1VAPermit CenteMpplications-HandoutskPermil Applicat ions1PDF skElectrica I Permit Application Revised I -17-19.docx RESIDENTIAL NEW RESIDENTIAL SERVICE O New single family dwellings $180.00 (including an attached garage) O Garages, pools, spas and outbuildings $120,00 ea 0 Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES O Service change or alteration $120.00 (no added/altered circuits) O Service change with added/altered circuits $100.00 number of added circuits 510.00 ea O Circuits added/altered without service change $60.00 (up to 5 circuits) O Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea O Meter/mast repair $80.00 O Low voltage systems560,00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $60.00 0 Temporary service (generator) $90.00 O Manufactured/mobile home service $100.00 (excluding garage or outbuilding) O Carnivals $100.00 Number of concessions ..... . ..... ... $11.00 ea Each ride and generator truck $1 1 ,00 ea ***EFFECTIVE JANUARY 1,2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction -- In all cases, a value of construction amount should he entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days, The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELE CAL CONTRACTOR: Signature: Date: 11/12/2019 Print Name: stin Taylor Day Telephone: 206-948-9803 Mailing Address: 15323 NE 90th Street Redmond WA 98052 City WAPem-iit CenterOipplicntions-liandoutsWermit Applications \ P )F'\ElecIricaIPerrnfl Appl ication Revised 1- 17-19.ducx State Zip OFF HOURS INSPECTION Reimbursement auto conduct iaspection inspection activities during offhours. Date: Permit Number: EL -0949 Requested By: Justin Taylor Contractor: Precision Electric Group Inc. Inspection Information Project Name: Cellnetix Project Address/Location: 12501 E Marginal Way S, Tukwila, WA 98168 Requested Date for Inspection: 4/11/2020 Requested Time: 3 PM AM / PM Contact Name: Rob Gleason Phone Number: (206) 948-1522 Inspection Requested: Service ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $105.00 per hour (minimum total of $315.00)' This is to be paid at the tirne of request. The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate irivoice will be issued for alt inspection time in excess of three (3) hours. Sharman ��������h�Fr� corn, :1:tric Group Inc, ';'''Atiat7g402s0804 1070510-M0' Signature: Date: 04/10/2020 Printed Name: Justin Taylor WA*rmit Hours Inspection a017.doc" Ott Approved: Disapproved: Paid: Receipt No: Date of Approval/Disapproval: Remarks: Authorized Reviewer: W:\Permit Center\Applications-Handouts \Templates \ Forms \Off Hours Inspection 1-2017.docx Revised: June 14, 2019 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206'493'1870 CITY OF TUKWILA 0017340000802374464500 Date: 04/10/2020 02:25:05 PM VISA CARD NUMBER: TRAN AMOUNT: APPROVAL CD: RECORD #: CLERK ID: X CREDIT CARD SALE **********0752 K $324.45 08075G 000 Rachelle {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 04/10/2020 VISA CARD NUMBER: TRAN AMOUNT: APPROVAL CD: RECORD #: CLERK ID: 02:25:05 PM CREDIT CARD SALE **********0752 $324.45 08075G 000 Rachelle Thank you! Customer Copy DESCRIPTIONS ACCOUNT QUANTITY I PAID PermitTRAK $324.45 EL19-0949 Address: 12501 E MARGINAL. WAY S Apn: 7345600580 ,$324.45 Credit Card Fee $9A5 Credit Card Fee R000. 69.90 .00.00 0.00 9.45 DEVELOPMENT $315.00 PERMIT REINSPECT FEE - AFTER HRS INSP FEE 8000.359.000.00.01 0.00 $315.00 , TOTAL FEES PAID BY RECEIPT: R20540$324,45 Date Paid: Friday, April 10, 2020 Paid By: KARISSA SHERMAN Pay Method: CREDIT CARD 08075G Printed: Friday, April 10, 2020 2:25 PM 1 of 1 CRWYSTEMS Cash Registei. Receipt City of Tukwila Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $6,269.59 EL19-0949 Address: 12501 E MARGINAL WAY 5 ,Apn: 7345600580 $6,269.59 ELECTRICAL $5,971.04 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $5,971.04 TECHNOLOGY FEE $298.55 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R19848 8000.322.900.04.00 0.00 $298.55 $6,269.59 Date Paid: Friday, January 24, 2020 Paid By: PRECISION ELECTRIC GROUP INC Pay Method: CHECK 014865 Printprl• 1=ririav Ian' Ian/ 7d 7n7n 11.c7 AM 1 of 1 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,537.54 EL19-0949 Address: 12501 E MARGINAL WAY S Apn: 7345600580 $1,537.54 Credit Card Fee $44.78 Credit Card Fee R000.369.908.00.00 0.00 $44.78 ELECTRICAL $1,492.76 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R19079 R000.345.832.00.00 0.00 $1,492.76 $1,537.54 Date Paid: Thursday, November 14, 2019 Paid By: TERRY DUBREAU Pay Method: CREDIT CARD 02673G Printorl• Thiircriav NnvPmher 14 7m 97.m PM 1 of 1 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 11/14/2019 02:00:55 PM CREDIT CARD SALE VISA CARD NUMBER: **********0227 K TRAN AMOUNT: $1,537.54 APPROVAL CD: 02673G RECORD #: 000 CLERK ID: Rachelle X (CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 1 1 /1 hill 0 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/14/2019 02:00:55 PM CREDIT CARD SALE VISA CARD NUMBER: **********0227 K TRAN AMOUNT: $1,537.54 APPROVAL CD: 02673G RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy haps://www.myvirtualmerehant.com/VirtualMerchant/transaction.do?dispatchMethod=pr... 1 1 /1 4/201 9 January 09, 2020 had City of Tukwila Department of Community Development JUSTIN TAYLOR 15323 NE 90TH ST REDMOND, WA 98052 RE: Correction Letter # 2 ELECTRICAL Permit Application Number EL19-0949 CELLNETIX - 12501 E MARGINAL WAY S Dear JUSTIN TAYLOR, 0 Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - C DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. CORRECTIONS/ #2 1). PROVISIONS OF 240.4(B) "NEXT HIGHER BREAKER" DOES NOT APPLY OVER 800 AMPS. SEE 240.4(C) AMPACITY OF CONDUCTORS TO BE EQUAL TO OR GREATER THAN OCPD. 2). GFPE REQUIRED FOR 2000 AMP MDP OCPD (SHEET E9.1) PER 240.13 3). NEW T-SB5 (SHEET E9.1) REQUIRES SECONDARY OCPD. PANEL SB5 (SHEET E10.3) INDICATES MLO. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No, EL19-0949 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development December 16, 2019 JUSTIN TAYLOR 15323 NE 90TH ST REDMOND, WA 98052 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL19-0949 CELLNETIX - 12501 E MARGINAL WAY S Dear JUSTIN TAYLOR, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. CORRECTION/ #1 1). PROVIDE OCPD VALUE FOR MDP FEEDER. FEEDER CALL OUT IS NOT SIZED FOR 2000 AMP. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. To better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Frankie Alexander Permit Technician File No, EL19-0949 _ 14 11111 " 112.4 P14, -.1a 711F_,171 -3K711 Frir1_q665 PERMIT COORD COPY t PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0949 PROJECT NAME: CALLNETIX SITE ADDRESS: 12501 E MARGINAL WAY S DATE: 01/10/2020 Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: uilding Divis on Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/14/2020 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 02/25/2020 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire D Ping [D PW D Staff Initials: 12/18/2013 PERM!T COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0949 DATE: 12/23/2019 PROJECT NAME: CELLENETIX SITE ADDRESS: 12501 E MARGINAL WAY S Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # DEPARTMENTS: Building ivision Public Works Fire Prevention Structural Revision # r after Permit Issued Planning Division LIIPermit Coordinator s PRELIMINARY REVIEW: Not Applicable E (no approval/review required) DATE: 12/24/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved P DUE DATE: 1/21/2020 Approved with Conditions E Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) r Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 11V Departments issued corrections: Bldg MI Fire D Ping LJ PW 0 Staff Initials: 12/18/2013 °PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19 0949 PROJECT NAME: CELLNETIX SITE ADDRESS: 12501 E MARG X Original Plan Submittal Response to Correction Letter # AY S Revision # DATE: 11/14/2019 Revision # before Permit Issued after Permit Issued DEPARTMENTS: fuildChlt)g Jy- Division Public Works n Fire Prevention Structural n Planning Division Permit Coordinator r • PRELIMINARY REVIEW: Not Applicable T (no approval/review required) REVIEWER'S INITIALS: DATE: 11/19/19 Structural Review Required DATE: P APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 12/17/2019 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date:01-09-2020 Plan Check/Permit Number: EL19-0949 LI LI Response to Incomplete Letter # Response to Correction Letter # 2 Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Deferred Submittal # Project Name: Cellnetix Project Address: 12501 E Marginal Way S Contact Person: Justin Taylor RECEIVED CITY OF TUKWIL, JAN 10 267n PERMIT CENTEP Phone Number: 206 948 9803 Summary of Revision: 1.) Ok, 2000A Frame LSIG breaker to be turned down to 1900a Ok, note added for breaker to be LSIG. 3.) Ok, added MCB Sheet Number(s): E9.1/E10.3 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Atil-) Entered in TRAKiT on 01 1)0 IP -001.6 RA1 9256-Cclinctix \ Drawinps \ Rcvisinn Stlhmittal Fnrm - Cit v Tukuri In hdor. City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. 1 11 Date: Plan Check/Permit Number: EL 19-09L9 El Response to Incomplete Letter # [E] Response to Correction Letter # 1 • Revision # after Permit is Issued E Revision requested by a City Building Inspector or Plans Examiner E Deferred Submittal # Project Name: CELLNETIX Project Address: 12501 E MARGINAL WAY S Contact Person: Tim Nichols RECEIVED CITY OF TUKWILA DEC 2 0 2019 PERMIT CENTER Phone Number: 425-402-9400.x119 Summary of Revision: -Panel SB5 now fed via dedicated 30kVA xfmr. Panel revised to 100a and UPS now fed via SB5. See E2.2W, E9.1, and El 0.3 for additional information. - Lighting Level 1 Revised to linears as shown on E3.1 - New MSBWD Panel Schedule added to E9.1 for reference only. -Response to plan review comment: (5) runs of #750A1 is good for 1925 amps. Next standard breaker size s 2000a s. Existin MDP is fed via 2000A Circuit breaker with LSIG capabilities. Sheet Number(s): E2.2W/ E3.1W/ E9.1/ E10.3 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: E Entered in TRAKiT on R A I 9256-C614101i z11-)rnwi n nclRaviginn Submittal Fn n City Of Tilleata In due. , hip000k DII,T11111 v, Labor & Industries (https://lni.wa.qov) Contractors PRECISION ELECTRIC GROUP INC Owner or tradesperson Principals DAVIS, MARK D, PRESIDENT FRANKE, PATRICK J, AGENT Doing business as PRECISION ELECTRIC GROUP INC WA UB I No. 602 434 703 15323 NE 90th St REDMOND, WA 98052 425-823-8600 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active Meets current requirements. License specialties GENERAL License no. PRECIEG969PH Effective — expiration 10/08/2004— 10/09/2020 .. .....istrator .. DAVIS, MARK D License type Master Electrician Bond Merchants Bonding Co (Mutual) Bond account no WA28604 Active Meets current requirements. License no. DAVISMD962DH $4,00000 Received by L&I Effective date 10/10/2011 10/20/2011 Expiration date Until Canceled First National Ins Co of Ameri Bond account no. 6572196 Received by L&I 10/08/2008 Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. $4,000.00 Effective date 10/20/2008 Expiration date Until Canceled Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. dill SABA 2 Nickerson Street Suite Seattle, WA E E E 0 C MECHANICAL EQUIPMENT CONNECTION SCHEDULE TAG DESCRIPTION HP IKW NA VOLTS I PHASE MCA FUSE (MOCP) DISC. SWTCH STARTER EN PWR CIRCUIT COPPER FEEDER SIZE TAG REMARKS NOTES AHU-1 ROOF TOP UNIT - 480V 13P 392 400 400 VFD BY DIV 26 NO MSWB #2 (2) 21/7C4#25oKCMIL AL & 1#1 AL GND AH11-1 1 EF-1 EX -RUST FAN 20 HP 480V 13P - - 60 VFD BY DV 26 NO P5B 26,28.30 3/4"C4#8 & 1#10 GND EF-1 EF-2 EXHAUST FAN 15 HP 460V 13P - - 30 VFD BY DV 26 NO P5B32,34,36 1/7C-4#10 & 1#10 GND EF-2 EF-3 EX-AUST FAN 2 HP 480V 13P - - 30 MAG. BY DIV 26 YES SBD8,10,12 117C4#12 & 1#12 GND EF-3 CU-1 CONDENSING UNIT - 208V ! 1P 29 - 60 MAG BY DV 26 NO 58139,41 3/411C3#8 & 1 #1 D GND CU-1 CU-2 CONDENSING UNIT - 239V / 1P 29 - 60 MAG BY DV 28 NO 58440,42 3/4"C3# 8 & 1 #1 o GND CU-2 ECU-1-1 FAN COIL UNIT - 208V / IP 0.63 - Sm - NO SB1.39,41 11 C3#12 & 1#12 GND FCU-1-1 FED VIA CU-1 FCU.l-2 FAN C IL UNIT - 208V l 1P 0.63 - Sm - NO SB139,41 1/7'C3#12 & 1#12 GND FC11-1-2 FED VA CU-1 FCU-2-1 FAN CCIL UNIT - 208V / 1P 0.63 - Sm - NC S8440,42 1/2+03#12 & 1#12 GND FCJ-2-1 FED VIA CU-2 FC1.1-2.2 FAN COIL UNIT - 208V / 1P 0.63 - Sm - NO SB4-40,42 1/7C-3#12 & 1#12 GND FCU-2-2 FED VIA CU-2 HRP-1 HEAT RECOVERY PUMP 5 HP 48W / 3P - - 30 MAG BY DV 26 NO P5B37,39,41 112'C3#12 & 1#12 GND HRP-1 HRP-2 HEAT RECOVERY PUMP 5 HP 48W / 3P - - 30 MAG BY DV 26 NO P5B-37,39.41 1/2"C3#12 & 1#12 GND HRP-2 EWI+1-1 ELECTRIC WATER HEATER 5.5 KW 277V / 1P 20 - 30 - NO P1-24 1l7C2#10 & 1#10 GND EWH-1-1 EWI+2-1 ELECTRIC WATER HEATER 90 KW 480V 13P 108.3 - 200 - NO MSWBD6 1 1/4"C3#3/0 AL & 1# 4 AL GND EWH-2-1 EWH-2-2 ELECTRIC WATER HEATER 15 KW 480V! 3P 18 - 30 - NO P7-22,24,26 1/7C-3#10 & 1#10GND EWH-2-2 _HNRP-2-1 CRC PUMP 1112 I-P 120V / 1P - - Sm - NO P8C-40 1/2"G3#12 & 1#12 GND 7U-1-01 TERMINAL UNIT 6 KW 277V / 1P 21.68 - 30 - NIO P137 1l7C3#10 & 1#10GNO 1U-1-01 'RJ 2-01 TERMINAL UNT 10 KW 277V 11 P 36.1 • 80 - NO P9-1 3/4"C-2#8 & 1 #10 GND 1U-2-01 TU2-02 TERMINAL UNIT 10 KW 277V / 1P 36.1 - 60 - NO P9-7 3/4"C-248 & 1#10 GND TU-2-02 TU-2-03 TERMINAL UNIT 6 KW 277V / 1P 21.66 - 30 - NO P9-9 1/7C-2110 & 1#1 D GND TU-2-03 7U-2-04 TERMINAL UNIT 10 KW 277V / 1P 36.1 - 60 - NO P9-11 314"G2118 & 1#10GND 7U-2-04 1U-2-05 TERMINAL UNIT 10 KW 277V 11P 36.1 - 60 - NO P9-13 314"C-2#8 & 1#10 GND 7U-2-05 IU-2-08 TERMINAL UNIT 2 KW 277V ! iP 7.22 • 30 - NC P9-15 1!2'C-2#12 & 1#12 GND TU-2-06 1U-2-07 TERMINAL UNIT 6 KW 277V 11P 21.66 - 30 - NO P9-17 1/7'C-21110 & 1410 GND TLL2-07 TU-2-08 TERMINAL UNIT 8 KW 277V ! 1P 28.88 - 80 - NO P9-10 3/4"C218 & 1 #10 GND TU-2-08 111.2.09 TERMINAL UNIT 10 KW 277V 1 1P 38.1 - 60 - NO P9-12 314"C-2#8 & 1#1 D GND 111-2-09 TU-2-10 TERMINAL UNT 5 KW 277V 1 1P 18.05 - 30 - NO P9-2 1/7C2#10 & 1#10 GND 1U-2-10 TU-2-11 TERMINAL UNIT 5 KW 277V 1 1P 18.05 - 30 - NO P9-4 1/7'C-2#10 & 1#10 GND 1U-2-11 TU-2-12 TERMINAL UNT 5 KW 277V / 1P 18.05 - 30 - NO P9-3 1!2"C-2#10 81#10 GND TU-2-12 1U-2-13 TERMINAL UNIT 10 KW 277V / 1P 36.1 - 60 - ND P95 3/4"C-2#8 & 1#10 GND TU-2-13 T1.1-2-14 TERMINAL UNIT 8 KW 277V / 1P 28.88 - 30 - NC P9-18 314"C-2#8 & 1#10 GND TU2-14 TU-2-15 TERMINAL UNIT BKW 277V!1P 28.88 - 30 - NO P9-22 314C-2#881#10GND TU-2-15 11J-2-16 TERMINAL UNIT 9 KW 277V l 1P 32.4E - 60 - NO P9-20 3I4"C-2#8 8 1#10 GN0 TL12-16 1U-2-17 TERMINAL UNT 6 KW 277V ! 1P 21.66 - 30 - NO P9-24 1/7C2#10 & 1#10 GND 1U-2-17 1U 2-18 TERMINAL UNT 6 KW 277V I IP 21.66 - 30 - NO P9-26 117G2#10 & 1#10 GND 1U-2-18 TU2-19 TERMINAL UNIT 10 KW 277V / 1P 36.1 - 60 - NO P9-16 3/4'C-2#8 & 1#1 D GND TU-2.19 TU 2-20 TERMINAL UNIT 7 KW 277V / 1P 25.27 - 60 - NO P9-8 314"C-2#8 & 1#10 GND 1U-2-20 11J-2-21 TERMINAL UNIT 1 KW 277V / 1P 3.61 - 30 - NO P9-21 1/2"C-2#12 & 1#12 GND 1U-2.21 7U-2.22 TERMINAL UNIT 2 KW 277V 1 1P 14.44 - 30 - NO P9-19 1/7'C2#12 & 1#12 GND 7U-2-22 1U-2-23 TERMINAL UNIT 5 KW 277V / 1P 18.05 - 30 - NO P9-25 117'C-2#1D & 1#10 GND 11J-2-23 1L1.2.24 TERMINAL UNIT 4 KW 277V / 1P 14.44 - 30 - NO P9-14 1/7C2#12 & 1#12 GND 7U2-24 1U2-25 TERMINAL UNIT 2 KW 277V / 1P 7.22 - 30 - NO P9-27 1/2"O-2#12 8 1#12 GND TU2 25 11.L2-26 TERMINAL UNIT 4 KW 277V / IP 14.44 - 30 - NC P9-6 1/2"C-2#128 1#12GND 1U-2.26 1U2-27 TERMINAL UNIT 2 KW 277V 1 IP 18.05 - 30 - NO P9-23 1/7C-2#10 & 1#10 GND 1U-2 27 1U-2-28 TERMINAL UNIT 2 KW 277V l 1P 7.22 - 30 - NO P9-29 1/7C-2#12 & 1#12 GND 1U-2 28 FP-1B-14 FAN POWERED BOX EXISTING 277V / IP - - (E) - NO EXISTING EASING FP-1 B-14 RELOCATED UNIT FP-1B52 FAN POWERED BOX EXISTING 277V/1P - - (E) - NO EXISTING EXISTING FP-1B52 RELOCATED UNIT FP-1B-53 FAN POWERED BOX E)aS11NG 277V! 1P - - (E) - NO EXISTING EXISTING FP-1B53 RELOCATED WIT FP-23-01 FAN POWERED BOX EXISTING 277V 1 1P - - (E) - NO EXISTING EXISTING FP-2B-01 RELOCATED UNIT FP-28-02 FAN POWERED BOX EXISTING 277V! 1P - - (E) NO EXISTING EXISTING FP-20-02 RELOCATED WIT FP-26-03 FAN POWERED BOX EXISTING 277V / 1P - - (E) - ND DOSING EXISTING FP-28-03 RELOCATED UNIT FP-2B-12 FAN POWERED BOX EASING 277V / 1P - - (E) - NO EISTING EXISTING FP-28-12 RELOCATED UNIT FP-2633 FAN POWERED BOX E)4611NG 277V / 1P - - (E) - NO FISTING EXISTING FP-2B-33 RELOCATED UNIT FP-2840 FAN POWERED BOX EXISTING 277V 11P - (E) - NO EXISTING EXISTING FP-2840 RELOCATED UNIT FP-2841 FAN POWERED BOX EXISTING 277V! 1P - - (E) - NO E)SI1NG EXISTING FP-2B-41 RELOCATED UNIT FP-28-43 FAN POWERED BOX EXISTING 277V / 115 - - (E) - NO FISTING EXSTING FP-2B-43 RELOCATED UNIT FP-213-45 FAN POWERED BOX EASING 277V / 1P - - (E) - NO EASING EXSTING FP-2B-45 RELOCATED UNIT GENERAL (APPLIES A. B. C. D. E. F. SCHEDULE (APPLIES 1. EQUIPMENT CONNECTION TO ALL EQUIPMENT LISTED IN THE ABOVE INFORMATION IS FOR SUBMITTALS FOR ACTUAL LOADS, LOCATE ALL DISCONNEC11MG MEANS ABBREVIATIONS: FRS: HORSEPOWER RATED Sm: MOTOR RATED TOGGLE TS: TOGGLE SWITCH, 16-AMP ALL DISCONNECTS ARE 3 POLE PROVIDE A ROOFTOP WEATFERPROOF CONNECT FIRE SMOKE DAMPERS REFER TO MECHANCAL DRAWINGS PROVIDE DISCONNECT TOGGLE NOTES TO SPECIFIC EQUPMENT AS NOTED DUCT SMOKE DETECTOR SCHEDULE NOTES SCHEDULE) A SPECIFIC MANUFACTURER. THE ACTUAL MANUFACTURER FOR THE EQUPMENT MAY BE DIFFERENT COORDINATE WITH MECHANICAL EQUIPMENT CIRCUIT AMPACITY AND OVERCU2RENIT PROTECTION REQUREMENTS PRIOR TO ELECTRICAL ROI GHIN. PER NEC AND AMU REQUREMENTS. STARTERS ARE SEPARATELY MOUNTED UNLESS OTHERWISE NOTED. MOTOR DISCONNECT SWITCH WrMOVERLOAD PROTECTION, 16,AMP MINIMUM, RED PILOT LIGHT. PROVIDE 1-POLE OR 2-POLE AS REQURED. SWITCH. MINIMUM, RED PILOT LIGHT PROVIDE 1-POLE OR2-POLE AS REQURED. UNLESS NOTED OTHERWISE. GA DUPLEX RECEPTACLE WI1HIN 25 FEET OF ALL ROOF MOUNTED HVAC UNITS AS REQUIRED BY NEC. TO A 120VAC 20 AMP CIRCUIT ROWED THROUGH A RELAY CONTACT (NC.) IN THE FiRE ALARM CONTROL PANEL. FOR ALL FIRE SMOKE DAMPER LOCATIONS AND QUANTITIES. PROVIDE ALL APPURTENANCES AS REQUIRED. SWITCH WITHIN SIGHT OF THE DAMPER MOTOR CONTROLLER AND DAMPER MOTOR. IN 'TOTES" COLUMN) KEYPLAN ELi 9-0949 9057 6400 www.sabarch.com PRECISION ELECTRIC GROUP �-. INC �...-� 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 E CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT D C r 1 1 L. ` F EVIEgW D F01C ! LnNEPA 70 - NECTH 1 JAN 2 ,12020 City of Tukwila BUILDING DIVISION SPACE FOR OFFICIAL CITY USE ONLY 1 J MECHANICAL EQUIPMENT CONNECTIONSF DAT CHEDU"TT'-'11 /11 /2019 CHECKED BY TN PROJECT NUMBER 19256 B A RECEIVED CITY OF TUKWILA 1 3 4 5 6 NOV 1 4 2019 PERMIT CENTER SABA 2 m PARKING LOT SOUTH 124TH ST BUILDING A (NOT IN SCOPE) PARKING LOT EXISTING 1 500KVA XFMR TO BE REMOVED AND NEW XFMR INSTALLED IN EXISTING LOCATION. 1 1 1 1 PARKING LOT 1 PARKING LOT —(8)4"C-4#750KCMIL AL 1 11 11 12501 E MARGINAL WAY S BUILDING B (SCOPE OF WORK) (E) MD4 EXISTING ELEC RM NEW ELEC RM PARKING LOT PARKING LOT PARKING LOT PARKING LOT PARKING LOT ELECTRICAL SITE PLAN SOUTH 126TH ST S AVM 1VNIOWN 3 KEYPLAN SCALE: 1' = 40'—O" ELi 9-0949 °NORTH 2 Nickerson Street Suite &SOgUttlle, WA 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone:425-823.8600 Fax: 425-823-8655 E CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Pathway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT D C ✓ CMPU D FO1:( C -<OF. 7CC 0.{ECTM.1 tit 121213 .11 t 1 City o1 Tukwila UUILDING DIVISION SPACE FOR OFFICIAL CITY USE ONLY ELECTRICAL SITE PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 B E1.1 A RECEIVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER SABA 2 Nickerson Street Suite Seattle, WA 01 January, 2000 NORTH 1 ST FLOOR WEST POWER PLAN CLASS I, DMSION 2 HAZARDOUS AREA IN WASTE/HAZMAT STORAGE. PROVIDE PROPER INSTALLATION AS REQUIRED. AUTO®DOOR SB1-37 79,11 AUT ® 0R 5 PC2 561-37®1 re, I SB1-37 ®1 PRINTER 1® 3 0 4,(4) 4,(4) 9 2 4.(4)01 I®6 2 RIF 8 ELEV-1 14@H 2 AUT0®D0OR 5 P1-3,5,7 CAB LTS KD ELEV-2 ELEVATOR SHUNT TRIP 'ELEV' I ELEV-3 10,00) 10,(10) 10,00) H 12 12 SCALE: 1/4" = 1'-0" GENERAL NOTES 1, CIRCUIT NUMBERS SHOWN REFER TO PANEL P2A UNLESS OTHERWISE NOTED. 2. CIRCUIT NUMBERS SHOWN WITHIN (—) ARE TO BE CONTROLLED VIA CLOSEST RELATIVE OCCUPANCY SENSOR. SEE E3.1 FOR SENSOR LOCATIONS. IF NONE PRESENT, PROVIDE OCCUPANCY SENSOR FOR RECEPTACLE CONTROL FLAG NOTES DOCK LEVELER. 208V/3P/20A. COORDINATE EXACT LOCATION PRIOR TO ROUGH —IN. KEYPLAN ELi 9-0949 20P957 6400 www.sabarch.com E PRECISION ELECTRIC GROUP 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT ,.0149PL At7OC FOTT I - Nee ...i2 i32a city of Tuk*ils iiUILOING DIVISION 7 SPACE FOR OFFICIAL CITY USE ONLY E E D C B 1ST FLOOR WEST POWER PLAN DATE CHECKED BY PROJECT NUMBER 11/11/2019 TN 19256 E2.1W A RECEIVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER 1 2 3 4 5 6 SABA 2 Nickerson Street Suite S®uttle, WA w NPA Nvv N ROTOR 84-4 GENETIC C08A5 84-10 B4-6 ROTOR 84-8 CODAS B4-6 P6C-15 B4-2,4, 6,8,10 P6D-3 4 5 P6D-3 LICE 84-14 P6C-17 84-12,14. 16,18 NEXUS 84-14 THERMAL 94-16&18 4 -30 64-1 80• 83-111 i V HOOD FRZR� rP6C-32 B3-1 'I B3F 2 RE84 r8 --3 II i -2 'I B4-5 REF 0I 83-26 ... B3-28 ij MW P6C-23 P6C-19,21, 23 84-20,22, 24 B4-24 -20• 64-9 DNA B4-11 M1YS85-1 585-2,4 SB5-33 ® aSB5-7 SB5-6,8 S85-59 9 2 SB5-10,12 5 DRYING P6C-25 INC B4-25 INC 84-27 9 DRYINGI91 P6C-27 I ISO 0! P6C-29 1 5841 P6C-31,33 84-23 j� i(E) I I ' o P8B-11,13,(15) 1(E) HISEO 5 0 84-133D6C-22 REF FRZ 84-15 64-19 B4-17 NEXUS 84-13_I B4-7,9,11 P8C-37,39,41 PBA-26,(26) P84-26,(26) +60- IA to P8A-26 1I (E) Ki] P8B-24,(26) j P8A-384 84-21 I i IKDPB.A-27,(29) 'RIMER P8A-31 * PRINTER P8A-33 PRINTER P8-25 P8-23 P8A-26,(26) C t91/110 P8-27,(27) P8A-26 P8A-26,(26) 0 P8-227,(27) P8A-35,37,(39)04 OP8B-21 0P8B-21 P8-1133,(13) 145P8-13,(13) P8 j3 P8-27,(27) P8-27,(27) S P8B-23,(23) P8-23,(23) P88-23,(23) P88-23,(23) P88-25,(25) P88-25,(25) ICI 60 P88-25 P88-17,07) ®) P88-25(25) id P88419 P868-19 P8A- ROE l#F REF P8A-2 OW* P8A-10 P8A-4 P8i 34 *PBB-27 *P8-29 DM0 PBB-10 DISP P8B-8 MW to +44'60' */+P88-14,16,18P86-34 IA 28,30,32 P8A-12giw AUU 0 00R P8B-21 COPIER *P8-33 P88-12 *COFFEE P8-31 DW *MW P8-35 * 8-29 P8A-23 DISPOSER P8-12 *REF P8A-21 P8-®(11) P8-111,,(11) P8-11,(11) I0PB-11,01) P8-9,(9) ®I10P8-9.(9) P89,(9) P84(9) P8B�34 (E) E) COPIER *P8-20 P8C---2• 0 P8i 22 5 +QP8A-6 P8A-6,(6) (E)©li tE_'{E) (E) kQ(E) (E)C-�i 5 P8-17 KDP8-37,39,(41) 2ND FLOOR EAST POWER AND COMMUNICATIONS PLAN (E) P8-2,4,(6) ®I (E) (E) (E) (E) (E) (E) 5 ((E) ((EE) P88-35,(35) 191 PBB-35,(35) t31 Cl P8A-6,(6) P8+A68�1 PP8A-6,(6) PP88A-6,(6) 01 PP8A-6,(6) 9 P8A-6,(6) (E),c)I P8i,(8) (E) iP 5 (E) 45 (E) (E) 5 (E) COPIER P8-10 P8-8,(8) 16 00 P8-8 PB-8,(8) P8-8 ?01 +60 ( E ) (E) (E) co co co (E) (E) (E) P8A-14,(14) " 01 0:)(E) P8A-14 P8A-14,(14) ICI P8A-14,(14) PgA=14 tQ (E) • P8A-14,(14)0I P8A-14,(14) 45 (E) gg (E) PBC-17,(17) leP8C-17,(17) t`(E) (E)t3' ((E) (E) 1: (E) (E»l (E) t6(E) (E) (E) 45 ) 45 (E) 5 (E) (E) 1114 (E) (E)(0 mud (E)Q1 {E)�1 tQ(E) P8C-17,(17) P8C-19,(19) P8C-17,(17* (E) (E) (E) Al I. (E)QI (E)� COPIER P8C-180 (-5 (E) I> E) P8-19,(19) (E)e t®(E) P8-19,09) (E)gii SCALE: 1/8" = 1'-0" CIRCUIT NUMBERS PREFIX: 'P6' ' P6A' 'P6B' 'P6C' 'P6D' '61' 'B2' '63' ' B4' 'B5' 'P8' 'P8A' ' P8B' 'P8C' PANEL: P6 (208V) P6A (208V) P6B (208v) P6C (208V) P6D (2084) SB1 (208V) 562 (208V) SB3 (208V) SB4 (208v) SB4 (208V) P8 (208V) P8A (208V) P8B (208V) P8C (208V) FLAG NOTES 16KVA UPS. 208V/1P/100A FEEDER. GENERAL NOTES 1. PROVIDE WIREMOLD 3000 SERIES WITH RECEPTACLES EVERY 24" ON CENTER. 2. CIRCUIT NUMBERS SHOWN WITHIN (_) ARE TO BE CONTROLLED VIA CLOSEST RELATIVE OCCUPANCY SENSOR. SEE E3.2 FOR OCCUPANCY/SWITCH LOCATIONS. PROVIDE ADDITIONAL SENSORS IF NONE PRESENT. WIREMOLD TYPE 1 (GP CKTS) +48" NORM CKTS -TYPICAL SB CKTS GP CIRCUITS WIREMOLD TYPE Z WIREMOLD TYPE 3 (GP & SPECIFIC CKTS) (SPECIFIC CKTS ONLY, NO GP) DIFFERENT CKT ij CKT FOR SPECIFIC 0 EQUIP +48" NORM CKTS SB CKTS TYPICAL 24"O.C. GP CKTS & SPECIFIC EQUIP CKS CKT lii CKT #2 0 +48" as KEYPLAN ELi 9-0949 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 E CASE PIF ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA D C CONSTRUCTION DEVELOPMENT ItEViEWEL FOR COMPLIANCE WITH! RrPc YC-Nee 1 1 city of Tukwila UUILDING DIVISION SPACE FOR OFFICIAL CITY USE ONLY 2ND FLOOR EAST POWER PLAN DATE CHECKED BY PROJECT NUMBER 11/11/2019 TN 19256 B E2.2E A RECEIVED CITY OF TUKWILA NOV 142019 PERMIT CENTER 1 S A B Architects E E A 0 a) LE csd as 'U 0 FP6A-2,4 81-1 I 106.113- P8-31 EMB P6-29 lc EMB P6-33 U P6-21 6A-18 1-23,25 REF 81-23 EMB P68-9� DAB ' P6B-9,11,13 P6B-11 81-9 EMB {P61113 I } EMBEDDING W201A 81-19,21 ▪ P6A-IS---- . 81-25 i P6-19 1182-1 P6A-24 B2-3,5 _ t 7911 +1e 0e1,�1 B1-11 81-15 B1-27 SPECIALS W225 , P6A-14 P6k-16 PROCESSING W223 i l FRZ FRZ REF - COPIER P8B-17,19 B-5 B-7 P6B-3 P6B-7 P6 P6A P5 P6D I; l©P6A-34 P5B PBC; T B1-13 81-17 COPIER P6-19 REF REF B1-2 B-4 B1-12, 14,16 18 20 IHC INC B1-20 B1-12 IHC IHC IHC B1-18 IHC B1-12 I HC 81-10 B1-14 B1-29 CLOSET I' MICROTOMY W201C STRAIN B1-30 P6A-30 B1-30 nSB2 PGA-34 . SaISBCFI IESBDL GROSSING W201D 86-15,17, 86-6,8,10,12 2,4 IHC B1-16 IHC B1-14 01-24 STRAIN B1-28 P6A-8 B2-2 CRYO_QI P6A-33e6 ''h REF • 82-4 HISTOLOGY STORAGE •.- -. .T W�Zrr I I LL L___1 is Lae Eli P6A-20 83-30 B6-14,16 B6-22,24,26 18,20 P68-16 i> TISSUE TISSUE. TISSUE TISSUE 83-1 P68-17P60-19 P60-21 6-20R P68-23 P6B-28,30 n P68-18 81-6 01-26 CYTO PROCESSING LW?01 I BSC BSC P65-39 P68-27 P66-27,32,39 83-5 B3-3 P6B-33 "'P6B-37 81-32 81-34 P8A_29 P6A-21 " P6A-17 B2-10 82-12 ACCESSIONING IW2O1E1" P6-40 B2-18 P6A-19 'I B2-14 I CENT PC6-1', CENT P6C-3 CITIr P68-34,36 P6C- PSC-1,3,5 83-7 7,9,11 83-9 PAP STORAQE ,Wr201 H P6A-29,(26'. CIP6A-29,(29) V K-IN W219 r _82- L P6A-13,(13 P6A-15 q 82-16 I®P6A-13,(13) i I PE -354114 P6A-37 +60- aP6A-29 QP6A-29'( I' rr U R ''MO ! I .le WPM-11 I PM-11 82-28 pap_.1 P6A-I3,(13) P6A-13,(13) ®i I r \IW P6-30 P6A-23,(23)00tP6A-23,(23) ' 132 22 le u..____. �...... -.. COPIER P6A-23,(23) I P6A-23,(23) P6-4,(4) 4' . P6-25,(2S)I: ._-P6-25 (25)'Ii Er, P6A-2 P6A-20I CAT 1 PANTHER B3-15 B3-21 B3-15,17,19,21 PANTHER B3-17 P50-38,40 83-11 ii r S83 >1 aP6-6,(6) ari 1ti PB-6,(6)S P6-4,(4) MO P6-4,(4)®Ip-8,(6) DOP6-6 P6-6,(6) P6-6 12 o�R III 'i� 2ND FLOOR WEST POWER PLAN SCALE: 1 /8" = 1'-0' CIRCUIT NUMBERS PREFIX: 'P6' 'P6A' 'P6B' 'PSC' 'P6D' '61' '82' 'B3' '64' '86' PANEL: P6 (208V) P6A (208V) P68 (208V) P6C (208V) P6D (208V) SB1 (208V) S82 (208V) S83 (208V) SB4 (208V) S86 (208V) FLAG NOTES CEILING PANEL. PROVIDE CIRCUITS SHOWN FOR EQUIPMENT BELOW. WALK-IN EVAPORATOR. 120V/1 P/0.8A/SB. ALK- CON • S0 OR XAW • ATION PRIOR TO ROUGH -IN. 12b /1P /SB STACK 30KVA TRANSFORMER ABOVE 150KVA TRANSFORMER. GENERAL NOTES PB_4,(4) s P6-25,(25) 1. PROVIDE WIREMOLD 3000 SERIES WITH RECEPTACLES EVERY 24" ON CENTER. 2. CIRCUIT NUMBERS SHOWN WITHIN (_) ARE TO BE CONTROLLED VIA CLOSEST RELATIVE OCCUPANCY SENSOR. SEE E3.2 FOR OCCUPANCY/SWITCH LOCATIONS. PROVIDE ADDITIONAL SENSORS IF NONE PRESENT. WIRFMOLD TYPE 1 (GP CKTS) +48" NORM CKTS TYPICAL 24"O-C. SB CKTS GP CIRCUITS WIREMOLD TYPF 7 WIREMOLD TYPE i (GP & SPECIFIC CKTS) (SPECIFIC CKTS ONLY, NO GP) CKT 6 CKGT #2 +48" +46" NORM CKTF TYPICAL 24'O.C. GP SB CKTS CKTS & SPECIFIC EQUIP CK5 DIFFERENT CKT j CKT FOR SPECIFIC a EQUIP P6=25,(25)61 BSC P6C-18 P6C-6 B3-25,27, 29,31,33MISEQ B3-31 --Ti lJr- UCR `' COPIER 83-12 P6C-28 • PSC-24,26,28 B3-10,12 ELi 9-0949 I 4 I City at Tukwila BUILDING DIVISION KEYPLAN va if A I WWI WA PA rl EILI9e0cMci 2 Nickerson Street Suite SUQttle, WA 20P957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425.823-8600 Fax: 425-823-8655 E (PFCASE ENGINEERING Consulting Electrical Engineers E 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 E REVISIONS: A 1 \ MECHANICAL CHANGES 11-13-19 A LIGHTING CHANGES 11-21-19 A TUKWILA COMMENTS 12-19-19 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT D C CORRECTION LTR# 1 RECEIVED CITY OF TUKWILA DEC 2 9 2019 PERMIT CENTER SPACE FOR OFFICIAL CITY USE ONLY B 2ND FLOOR WEST POWER PLAN DATE CHECKED BY PROJECT NUMBER 11/11/2019 TN 19256 E2.2W A 1 2 3 4 5 6 5 A B Architects' E E E D c B 1A w. ie RIX r 4.*TEORHAZMAT "• •..... i .. ' S TA'GE .. : ......... : ... . wT0 I..i• x1. .1 r 1 ST FLOOR WEST LIGHTING PLAN c Re 1 R6 1 R6 1 Li(44') en, L18RARY ` STORAG ::..W102.::. L_ LI (4'). L1X(4') L1(36) M•P.\\\\\\\tiM•h.................•M................ .•F. 1b Ib. 1b • L1(4') .......... .. .......... .. ............................................. .. FICE R2 1 1 ........................... LI(41 .. . R6X i 1 1 R6 R6 1 STOCKROOM' W105 R6 R6 1 R6 1 Tr R�� T 1 L1(4) ..................... ............... L1X(4') 1 s .L td i i 1 LI X(4') L1(4') 1 Six ElEV-6 I-0 art/ PI T -1 R2 1 R2 1 . r-j1 L..1i 1.i ,i MECH �!..�-! SP Wa , six ! ELEV-4 ELEV-6 a R2X ELEV-4 C i SCALE: 1/4- = 1'-0" 0. GENERAL NOTES 1. CIRCUFT NUMBERS SHOWN REFER TO PANEL SDB UNLESS OTHERWISE NOTED. 2. REFER TO THE LIGHTING FIXTURE SCHEDULE, SHEET E0.1, FOR ADDITIONAL INFORMATION. FLAG NOTES PER WSEC C405.2.2 EXCEPTION #3, AUTOMATIC TIME CONTROLS WOULD ENDANGER OCCUPANT SAFETY AND THEREFORE MANUAL CONTROLS PROVIDED. PRIMARY DAYLIGHT ZONE PER WASHINGTON STATE ENERGY CODE. SECONDARY DAYLIGHT ZONE PER WASHINGTON STATE ENERGY CODE. a �if?SI+"-Y(1 - RAgC i 2 1Uti, Y. 1 ;Ay of Tukwila [WILDING DIVISION KEYPLAN EL1 9-0949 4'. 2 Nickerson Street Suite S1ttle, WA 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 E ea. CASE lir ENGINEERING Consulting Electrical Engineers E 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 E REVISIONS: A 1 \ MECHANICAL CHANGES � 11-13-19 A\ LIGHTING CHANGES 11-21-19 A TUKWILA COMMENTS 12-19-19 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT I I I I RECEIVED CITY OF TUKWILA DEC 202019 PERMIT CENTER L SPACE FOR OFFICIAL CITY USE ONLY 1ST FLOOR WEST LIGHTING PLAN DATE 11 /11 /2019 CHECKED BY TN PROJECT NUMBER 19256 E3.1W 1 2 3 4 5 6 2 SABA 01 January, 2000 RI 7 121 3 R1 3 121 3 R1 3 R1 3 R1 3 R1 3 121 3 X1 vizi 5/R1 2 HOUR 1 S OVERRIDE RI 7 ER72X $LY SLY IX 2ND FLOOR WEST LIGHTING PLAN SCALE: 1/8" = 1.-0" SECONDARY DAYLIGHT ZONE PER WASHINGTON STATE ENERGY CODE. 121 3 3 R1 3 R1 3 R1 3 31 V 121 3 121 3 3 R1 IR1X 3 R1 3 121 3 RI 3 R1 3 x1 3g 13 R1 11 R1 13 R1 Iii RIX 11 R1 11 P2 P2X 5/R1 5at sot 501 X 5/aR1 5/+R1 5/R1 P2X P2 P2 P2X X1 P2 Sys V �R1 7 Nv €47 R1 7 RI R1 7 IR1X 7 R1 7 R1 7 ER1 7 X1 7igt 71 71 71 IR1X 7 71 R1 7 71 R1 7 Al 7 71 7aRtx 7 71 5LV5LV 2 HOUR OVERRCE 121 7 71 R1 7 R1 7 9 R1 3 RI 11 li• t3b ... 13b. 13b . . • R1X RI Rl . ... R1X• . .�.13b 13b 413 RI RI 11 riR1X 11 R11 R1 11 NR I 11 �R1 ER, \RI1 `11 P2 P2X P2 Q] 5/R t 0 0 0 g P2 5/R1 5/R1 5/RI 5/R1 5/R1 5//RR1 5*1 5 ER1 XI 13114 R1 3 R1 NR1 Ill RIX 11 11 R1 11 R1 11 R1 �RI 11 11 R1 11 1 R1 IR1X 111 R1 13 R1 11 R2 9 582-23 E R2 9 U R2 9 R2 9 R2 9 R2 9 R2 9 t ER92 9 V Ir 0 R2 9 Vega R2 9 9 9 9 E R2 C+T R2 9 9 P2 9 R2 9 P2X R2 9 X1 9 19W R2X SVs 9 lir 9250 XI 9 R2 9 9 R2 9 R2 9 P2 P2 P2X X1 ci 2 HOUR J 616 OVERRIDE FLAG NOTES PER WSEC C405.2,2 EXCEPTION #3, AUTOMATIC TIME CONTROLS WOULD ENDANGER OCCUPANT SAFETY AND THEREFORE MANUAL CONTROLS PROVIDED. GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL SBD UNI FSS NOTED OTHERWISE. 2. REFER TO THE LIGHTING FIXTURE SCHEDULE, SHEET E0.1, FOR ADDITIONAL INFORMATION. NORTH ELi 9-0949 w N La 4, KEYPLAN 2 Nickerson Street Suite Seattle, WA 20P957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 E CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT D C ;ev CEWITHI ICOMPUq DO ' i I 2• ,.• 1 City of Tukwila BUILDING DIVISION I SPACE FOR OFFICIAL CITY USE ONLY 2ND FLOOR WEST LIGHTING PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 B E3.2W A RECEVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER 1 4 5 6 4 a v 2 Nickerson Street Suite SQtttle, WA N w N N M rd FWW FWVI W W W 2 2 SLY S3 P2 5a 1 SS P2 5a X1 2 HOUR ®17 OVERRIDE-- 6 $S 1X R1 15 P2X 5/ 1 R2X R2 R2 17/R1 17/R1 L1 R2 13 13 P2 5//RR1 R2 R2 R2 R2 R1 R1 15 15 1X R1 5 15 S3 =15 RI 15 R1 15 LR1X 15 R1 X 15 � 1553 P2X 5, 1 P2 SLv R2 19 R2 R2 X1 ® SLY 13 17/R1 17/R1 13 13 R2X iy 19 ® 19 17/R1 R5 P2X 5a 1 R2X R2 R2X R2 R2 19 19 19 R5a R1 15 R1 15 ® 115 R1X R2 R2 R2 R2 SLY P2 50/R1 19 R5a R2 1R1X 15b 121 15 P2 R1 0 15 5/RI P2X R1 15 5 R1 19 P2X 5®1 R2 R2X ® R2 19 ' 19 19 R2 17/R1 R2 Lef1199S R2X 17/R1 17/R1 R2 19 �v1 9( �V1 �R22 19 1g1`� 19 R2 R2 17/R1 2ND FLOOR EAST LIGHTING PLAN SLY RSa i R2X R2 l/a R2 R2 15 15 15 [15 rct R2 9 19 R2 R2 OVERRIDE 2 X1 P2XHOUR 17 N S 17/R1 19 19 19 R2 R2 17/R1 19 19 2 HOUR OVER RID 19 19 R2X s, PPr R2 ®. 156 15b... .. ..1 b. . ............... ........... R2 /1 P1 015 R2 1 15 P1 015 R2 P1 015 R2 15 vox 2 15 2 R2 15 17115 5 ® 15 5 SLY®15 2 HOUR OVERRIDE P2 P2 OR177//R1 177//R1 sLV v f2117 R2X 17 R2® 17 R2X R2 19 R2 R2 R2X Pr R2 15 15 �15 R2 5 2 2 15 R2 R2 R2 R2X 15 15 15 15b gX 2 15 15 15 15 x1 2® SLY R2 R2 R2 R2 v SLY P2X 17/ 1 HOUR 15 OVERRIDE P2 15 177/R1 P2 15 0 17/R1 15 R2 R2 R2 15 15 15 P2X P2 P2 X 0 0 17/R1517® a 17/R1 17/R1 17/R1 %1®g� R2 R2 R2 �2 HOUR �a R2 19 19 / d19 I�19 19 11 AA Sn R2 17/R1 R2 R2 17/R1 R2X 17 17/R1 17/R1 gJi'5-0----2 HOUR OVERRIDE R3 17/R1 17/R1 17/R1 19 v. R1 19 R1 R1 19 19 R2 17/R1 R2 17/R1 SLY R2 R1 19h R1X I 19h R1 R2X -1-R3--2 HOUR R2 OVERRIDE 17/RI xi EEO 17 Pr 17/R1 R2 17/R1 R2X 17 19h R2� RI 1$g R1 .i .19g_;19g R2 19 19 19 19 S R2 Svf 19 R2 SY5R2 R2 SysR2 R2 19 19 19 19 19 OVERRIDE R2 17/R1 R2 R2 15 R2 15 15 15 r cn x1 R2X 17g' 17/R1 R2 R2 I/a R6 R6 15 15 SLy-11-22 HOUR R2 SIDE 19 19 19 19 19 19 19 19 R2 R2 R2 Sv5 I/a R2 17/R1 17 Lai 17f/R1 • R2X R2 R2X Prr R2 19 19 19 19 PRIMARY DAYLIGHT ZONE PER WASHINGTON STATE ENERGY CODE. SECONDARY DAYLIGHT ZONE PER WASHINGTON STATE ENERGY CODE. FLAG NOTES PER WSEC C405.2.2 EXCEPTION #3, AUTOMATIC TIME CONTROLS WOULD ENDANGER OCCUPANT SAFETY AND THEREFORE MANUAL CONTROLS PROVIDED. PER WSEC C405.2.4 NO MORE THAN TWO GENERAL LIGHTING FIXTURES WITHIN PRIMARY AND SECONDARY DAYLIGHT ZONES, THEREFORE DAYLIGHT RESPONSIVE CONTROLS NOT REQUIRED. GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL SBD UNLESS NOTED OTHERWISE. 2. REFER TO THE LIGHTING FIXTURE SCHEDULE, SHEET E0.1, FOR ADDITIONAL NORTH KEYPLAN EL19-0949 9M°857 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT ClONIPLItsNCE WITH! City oi Tukwila BUILDING DIVISION SPACE FOR OFFICIAL CITY USE ONLY 2ND FLOOR EAST LIGHTING PLAN DATE CHECKED BY PROJECT NUMBER 11/11/2019 TN 19256 E3.2E A RECEIVED CITY OF TUKWILA PERMIT CENTER SABA. 2 Nickerson Street Suite S&®ttle, WA 01 January, 2000 .0.8 4.3 5.2... 1.4 '. to:. a4.7 to . . 0.8 5.3 Pir to 3.9 . 3.3 /8 1E2 to 4.9 '4.2 1.3 4.3 5.4 43 4.9 4.2 0.6 0.3 RI 0.0 O.e 1.3 2.4 to 2.9 2.8 2.4 1.1 1.9 2.1 2.2 2.2 2.0 Svs Svs R2 R2 1 2.6 3.z 2.7 3.3 2.1 Is 1.8 1.4 1.7 1.5 1.4 R2 R2 R6 '1.4 11.8 1.0 1.3 1.7 2.o 2.1 1.1 R6X 1 2.2 /9 2.9 3.3 1.1 '1.6 2.2 3.1 '4.0 R6 1.0 0.7 0F6 a 0.8 0 1.3 ♦e 2.6 3.e ♦as ♦s.o fa.7 ♦ .7 12 1.3 ♦os a 0.5 13.4 0.9 1.3 1.8 6 9.e '4.7 5.1 0.9 1 B 3.3 '4 6 ' ' 3.5 5.8 '2.8 3 �♦ ; 2.a 1 1 b.e 1.o 1.3 1.7 2.2 2.8 1.9 1.3 0.9 0.6 0.5 0.4 Ix1 ' '0.9 1 316 'at '0.8 0 2.8 2.6 +22 1.s 1.3 1.0 0.7 0.5 0.4 '0.4 0.7 0.8 1.0 1.3 to 1.8 1.9 1.9 1.6 1.4 1.1 '0.8 to '0.5 0.4 '0.3 0.8 0 6 1.2 1 .6 1.z :im. 0sbs O� 0.9 1. 0.9 0.5 0.4 0.5 to 0.6 hi he 0.8 0.8 1.7 0.6 '0.6 0.5 '0.4 ha 0.3 `0.2 Sp six ELEV-6 Fo 1 ST FLOOR WEST EMERGENCY LIGHTING CALCULATION 2.7 4.7 R6 +3.7 1.8 `3.8 RB 1 4.8 4.8 3.4 2.3 i.e 1.1 13.9 5.1 4.7 to 2.7 '1.9 1.4 1.0 4.3 2.4 2.5 1.8 1.3 1.0 4.4 `4. 2.1 516 3.8 2.5 2.9 2.2 1.e 1.2 0.9 2.5 2.9 3.0 2.8 '2.4 1.8 1.4 1.1 0.8 '20 2.3 1.4 2.2 1.8 1.3 1.0 0.9 0.7 1.5 R6 1.9 2. 11.6 is a1.7 1.7 2.1 2.1 2.1 2.6 2.s R6X 4.5 R2 1R I12 3.2 .3c Svs 4.2 '4.3 0.6 5.2 4.9 X10.3 '5.8 SLY ®1 to '8.5 5.s St X ELEV-6 1.s Sp ELEV-4 R2 12 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL P1 UNLESS OTHERWISE NOTED. 2. REFER TO THE UGHTING FIXTURE SCHEDULE, SHEET E0.1, FOR ADDITIONAL INFORMATION. FLAG NOTES PER WSEC C405.2.2 EXCEPTION #3, AUTOMATIC TIME CONTROLS WOULD ENDANGER OCCUPANT SAFETY AND THEREFORE MANUAL CONTROLS PROVIDED. PRIMARY DAYLIGHT ZONE PER WASHINGTON STATE ENERGY CODE. SECONDARY DAYUGHT ZONE PER WASHINGTON STATE ENERGY CODE. SCALE: 1/4- = 1'-0' Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min LIBRARY STORAGE_Floor Illuminance Fc 2.63 6.5 0.7 3.76 9.29 STOCKROOM W105_Floor Illuminance Fc 1.52 5.1 0.2 7.60 25.50 WASTE-HAZMAT STORAGE_Floor Illuminance Fc 3.30 6.0 0.7 4.71 8.57 NORTH ELi 9-0949 KEYPLAN 2040957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 E CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT D C r '1 I I I I I I L J SPACE FOR OFFICIAL CITY USE ONLY i 6080E L1wt T L ,'f N-PA a - I CITY of Tukwila 1 PUILOING ovIsi_ 1ST FLOOR WEST EMERGENCY LIGHTING CALCULATION DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 B ELX3.1W A RECEIVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER 1 5 6 SABA 2 Nickerson Street Suite SIAttie, WA 01 January, 2000 L L L 4 L L . ....... ......... .......... ...... I 1; 4' ' .1 . 1. 1. 1.4..1 • to t,.1..L.Yo. .4 .4. L. .Y, L. .L .L. L. L.L. .1 1. L. .4.L. .11 L. 1. .L .L. .L .i.'L. ............. . .L . L..4. L. V.:'::L•:.. V 4aa_Y L ' L' ' L . .... .. .. .... .. .. -tr4i:1,..ra 2ixL.4 I!' K>41d 4•L 4 1 is '.11 IA41i'1,' 4•'L R1 3d it•ii vtb. • .L L L 11 L 4 L 1 ��js)••1ISi t. 1i L L 4 E1111414)s �Y.L L IfI�LLL�It4•i..] to L L LL L L L L L L 4 4 L L L L L L L L 1. b b t.r L L L L Se L L L 4 bto L to L Sr is L L L 1r tr 4 t, L to 5s `n Ss to L L L to t+ is 1a L L L Si311L L L 4 L 1 4 L 12 So y L L 4 4 L L 1 t,' to ti'ta L. to. .L . to. .L .to. L. .Ys X'v ' L 1?b'M. 1,3a::tr...ti W 1' ',i 1, ' 4 ' 4' Qt� 4' la to{i 1. 1. . L �1�.4 . 4 . 1. !y' } . •U . L 1,36. t,. .t. 13b 1t'i' L '1 l to t1�b A:. t• i3b 4.•,'A: ' 1' '4 u'4 Lab 1;.'.t. LL L4 L L to L L L L L Ss L 1r f. 1, L L L L L L L L L L L to L L Is L L L L lA L le L L L L L L L L L 14 1r L L le L L 1A 1r 1e to 1a 1A L 1. L le to L to L to 4 L L L 4 to is 1s 11 x L L .a�..yyy,.�.�...,r.LL .��..�1}..���..,e. 0 1. t, L �iL L iif, L to 4 L L L to L S 1 } L to to lrL�.y�,Sa U i, 1•t.X1r L L Itv If�fl.�ItT..I t,L L to �j'L.L\\\III L L t., t •1.--1 i is Si L L L L 1!.Si L 1r L Is Egt. 10 L �1t\�v.1.�I1I) L ��K■l 4 L U S. L���t . �.1j U1rL)a LL21L• L L �'!l )a 4 2I L L L L r T/ LLL L L So L L L L } L• lL to is 1 1 4 U }e L L '`V } S ! ) {, U 4 U U 4i 1s11.1 tr 41 L )s 1 S L 1. L la la L L L L y So L 14 lA L L L L L 1i le to t+ L L L 1a 4 la L L la L y 10 y 1A L L L L to .j.� L t. L t, 4L LL L L L sela Is 44 Is 14 211 L L • laL is E31lti la I 4 RI +35s Is 12 1 1 tr y Sa RIX yLt+ 1 it to L 1. L L L�iXLL��y.��+�.3i,,.��.{{{,.�o�--�,,�i4 1a• LL la It`+ 11i11, 1aI111 ▪ 1.r L U S L 1111�1\Mt\V1111 }r Io {s 1 to L ,t la Se Sr 4 Sa Sr 10 L le L L '4,. L�L LL �1t1to'tl ,a ,a , L ,a ,A 12, 12 ,. Li fto 4 4 1 1 5 1 L \a t. ))x to 1 i1la L ��Itt\1, 111Fa1.L1Zl ,r L 1 1\ 11�t11L to to tr t+ 4 So L 4 L b L /�LL\\7/� 1 L L .r la L 1a I. L to Is L is 1A to to L L L to L to L 4 1A 10 1a L is 4 4 L 4 le 1. to �tii. L L 1.to LL �y1..�1 �}A�▪ �\}.���it 4 L 1 >,1 laL 1 ><iIt`A,Itl1+ le IIIIIt.,vt\Y'IIIs„, }, L L, IiLI1\ fl 4S.a L lr1t1 11!1 1 I ! 4 1. L�L��\,y�t 1 1 n 1.. to Is 12 to la Sr 12 is Is Is to to 1A 1A I. 4 la to la L Is 1A 1.r to to Is 10 to L to I, 1. L Is 1.r b l.a Is L L L L is 11 L is L IA is to L to la 1A Is to to la IA Is t. Sr la to L to • la �IfilA�111L 1to Ia1• Ytost L.tr is •�L L LUt ML LSa i.r Lbs 4la L,, is5s i.r 11\ I', L 1. IM1,Y'I.▪ L1 �i la 1A i. 4 4 4 hr Sr 1 U tr 1 I 1 L L Sr 1 1 t 1nI I I L L S+ t 1 t U 14 is ER11. 1e L L Sr 'M,a,A4,,,.��1I.,6>ai1AL �.1,. ,a �],., u1 t1\ L to L 1 t 4 \1 LIA I.i..��iL 4r�Kl1. 1> L L1 to1 L L So L L 1r L to U to iA So 1ttr1i1 Lis L t+ l4 1a L L IS to b.. 1> 4 to hs L L !r 1. to Sr L L le L it L la I• le to SA Ss t. Ss 1.e L L to 1A to 1a L ,. L L L Is L to Is la L So IA L 4o L Is L Ss Sr L 1a 1, L 1s L L lA L L 1. L Sr 12 L to L tr L as s t'L to L L L Xle to 4 to L is Xi 1r 10 to 4 Sr L is 1e L L 1a 10 to 1s L L L L L to L L is TA 12 is L S, Sr 4 to L 4 1A Io t. L 1A L L L L L L to ,A L toL L L L L L L to L L y 5a fa 4 L 1A fa L L P2 P2XP2P2 P2X %1 P2P2PZ%P2 P2P2X P2 P2 P2X P2P2 P2x4 L L6, L L L L � 5fR1 1, L U • �e� to {. Ss L S�a �i4 t.SA So4 }5•J.Rt▪ L 1. t. ,a .� L L tr L L L L tr L L � L LaQ Sr Ss to•®S 5�R1S�RI5�R15�R15�R1 5/R1 5�R1__glt5(Rt54RI • 54Rt 5(Rt 5.RR1 54R1 54R1 5{R1 LX1y L 4 L L y L 4 e./�. A Ir L L L L 1. 1a a to 4 LL 1r U Sr 1. 1,L y y "'SS'''' 1A 1. L y lA 1aLtoLtr bL L1aL it 1a A L 12 Io 1A5 L LIV 2 HOUR S Sos OVERRIDE V Rt Ri 3 3 RI R1 3 3 R2X 7 RI 7 R1 7 7 R1 7 la L L la 10 L !. s L la to is to is I., Is ya, �o la to L L L L 1 ▪ 1 lil t I7fl I. t� 92... L L is Ifl is to IA 1 L is L L L to L 1 1 t IS7 7 to la L L 1.a la to E 7 1 L 12 HOUR .11, OV RIDE le 1e Si S. L L L la L L 1. 1a to ,s L to t2 Sr 1. L �If77l% L L So to L Si L L t. L L L to 4 1A la L 4 12 4 t. L to is Si L L L to Sr la to L 4 L R1 is i i Ss to 7L to is 7 is E17tr 1, L IfLI }a L tole Ir I. 1 1 I 7 1a t, �7ti i L1.,E I I 4 t 12 is L to Sr to 1 SA stv t. OF5a L R2.4 to t Si to to Ss ® L la IA L L to L 1. Sr Si 4 la la A lA Is Is L L So Is L L 1. 1s le L SA to L le 1nAiJrt4, I. to L L 9 1. 5. L L L le to 1e to t.+ 1s L 4 to to to Is to to to {A L IsL t.r tr to to 1a L 12 tr Ss 4 Ito SW SW i.. S77i t, to L 1.s I. Eh t. L 5LV 4 is L L L L L L L L L to 4 b 1A 1 L L L L to 1a 1 \.e ,s L 1, to le it to t.r SA is L is 4 L L is L la L L L to L L L to 4 L L to L 4 L L L to to t 1. 7 t y L 1 1 4 to is L L 4 L 1. le to to is to to L to 1s L L L U 4 L 4 L to I2 h_1 Is L la S. S, S�to L to L la is L 12 �o y Erb y ..�..yyy,���,..ya 7• a��..--eo�a�KL4L• 4�K1X44L�7▪ 4�K77X to isla 4 L4L l� 4.44 4aL fA 4 L12 44 L is to 4 toL L t L to L L to 4 L 4 4 10 L L L L L L to to .'4', L, /1,'. L','4_ ,L 4, L ,L L_ ,L� 4.4 L L L is L L .4 01X f7�p. •4, . 4..4 Or." . Se \A 4 L • t, lfA Sr .L L 'L L. SA b Ir IA to 12 SA El! K7 I I L .1' 1 L 4 4'1.'L'4:7y 4'4 is L. .►a . to . t.. .4 . it. .4 4 . 4 7 di L L �77XL L 77i ,a !o to L L 1s L Kr to L L L 4 L ), 1 1 L to tr Is L L L to to L L t. 1. L L L I L 1.2 L L L L Se It Ss L L is 4 t,' L .J to %i t> Si ' 4 ' L' ... .. ... ... ..... .. ... .... ... ,, l\ 119:14 1: J\ �39 t. 1s to to Is L 1. So 1. 11: 11' to 10 I+ -14 1. I. 4 1' L IS R2 9 R2 Na 71,t, 1. ▪ 4.�7K7111.,.�'Th is to I7tl 1;. 1. }q\'1t RA. S. ! .. as V' 4 U Sh L to 1 {� is> s 5171\\171j1 L to t� L SA S 1a Si y� 'L Is Is 4 li L L to 4 to 2 ! to 1. is L L L L Sr to L L !. to to to 92 9 Ss 9 R2 92 R2 L 14 io ,e le to 14 I.r to R2 9 R2 9 Si 'L �7 to L Ef„7a. L,e�7ie7,�'a��9LS, Ut9se Ss�L L1 IaQ. la Ia 1 le 1A liL: 1r LD4 11 1 1 1 L 1.A 1. 1 I b h A 4 4 to L• L 4 t. to to Is is Is in la S• L 1a t, 12 to to. tr :. to t. 10 -L S. be to.. bA to 12. L •..t. '' ...L.. �A. I... 1. ...1e... L. 2ND FLOOR WEST LIGHTING CALCULATION PLAN L R2 9 R2 9 R2 9 R2 9 9 R2 R9545 Is to 4 to to to RA R2 9 R2 9 xi 2 HOUR Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min MODECULAR PRE_Floor Illuminance Fc 2.69 6.1 0.4 6.73 15.25 SCREENING_Floor Illuminance Fc 3.26 6.3 0.8 4.08 7.88 NORTH KEYP LAN EL19-0949 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Ns CASE Pr ENGINEERING Consulting Electrical Engineers Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT SPACE FOR OFFICIAL CITY USE ONLY 2ND FLOOR WEST LIGHTING CALCULATION DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 ELJ(3.2W A RECEIVED CITY OF TUKWILA PERMIT CENTER SABA 2 Nickerson Street Suite Seattle, WA 01 January, 2000 603 t�':'IL3a•'' . .• Sa .1, It is Se 1.' fill' I�°I%. .. Fit gd1.. .. I % �l 10 L. 13h 11 to 1 t\ I�a?. t.. So t11 I\ib L L Oh is 4't..'.1a" L 'fie LJ%, to 1 1 I fill. to 4 la 2 4 n L u 4 la 45LY 4 3 to L L to to to L t' L to L t, L ts t1 10 10 Lti-11 b to L 10 4 fie 1,. 11 10 la h" 1._ I I 1 12 It L L S. to I, la 4 I., t, to a0 t' to 0. L L to to to to te t, fill t, i, 4 So L SO Is 1. I to to to to L L to la to L to to S. to L S. t1 S. 1 to ty L to to to to to to to to t t. 4 S. to to to L L L to tr 1. 1. ih% 5. Se i5 1 4 L 4 to b. 1, la L to L . L to L L L to L L L L L 1. L 1, 4 L $SOI 4 L to 1s to 4 I. Is to 14 la to 14 to to 1a 4 L to to to 4 4 L 4 to L 4 L L to to SA 1. 1. Is Is » 9d 11 L L to Is 5s to L to tr L L X is b Sa L L 4 L L 17 to L 1M1Y-1 L Is S3 to L t. R1X $5 is 5, �15SA, to fix tR1 1a 1 4 to 4 L 4 to L In to II 1.0 IS3 sot fill .................. 1 R11 t 1 R4Is .bt1 i 15g L t6g - 1. 1 L S to. '.1% to, -'l is R11• IT, 154a3( RleslitI .L b. i 1 R7X R7 .. -. .... ..... ... ... -. 1 1111/ RI t o l Alg,L ell 1 R1 or L 1 t\ 1\V71159, L t 15A t. 15 r L 1 t S + 5. 5 1 5a 12 R1L .L R1k'.•." .i 15¢ 1,11514 . Sr .1 1 iL to1 1 . L. .1, -4t fill. 1 5q .L to R1" 5' R71� 1519t.14 1 LI R11 1 Rt..��,�,��,++1y��' 15g fill 1 t 1JJI \N11 1 1s 1. Ir 1. t to to 5 1a to to to S Si Is t, to 1 to 1, 1a fill L L fill. L 11 LOLV oa to L 1a It 4 to L L 19 t. L Ecistt, n L Lk1 151,, L eS5 iL to L to to te to to to 4 to to to 1s Io L to Sr L to to P2X to L to t. 4 5/R1 o to P2 P2 P2X P2 P1%2`t 1s I, to la Se to o to Se 14 L Sa Sr 4 to L F:./ 11 to 5 0R1 5�RIs S. t. 1 5R1 5 R1 5/R1 1 to to 1.1 s t• to t. lo 4 S. to 5. L 4 to t4 ill to is 1, to to SLV Ire is 4 4 L I L R L la L 19 5 is to L to 1 1i1 fill 15 'so 515 1. L 1r L Ill. Is itiT5 1X1' 1I L to t. t. 11 to 4 L 11 So to L is L to to 1, Lb L to VSLVSo to I, Io L to L to So to to 14 la to P2X t. L to O L Ir to I. to to to P2 to 514 5aR1 L to to . 1a ,♦ to 2,1 t • in to to • 0O.©y to Sr . a." 1i - 4151 4 ta to 4 to to to S. R7 I.. 10 to L 15 L Ito bar L 122 1* 105 to Ito Ito Ira Ira 11 L R2X R2 t. 11 it los to fill 1;s15 t. to to .75 to to to la t. to L to polo I. 1a 11 4 Sr 11P212 R2 fill 1:415112 is 1. 15% 115 to to 015 P1 [44,5 fir tot to L. 1, L L 10 5o P2X Ss to to 5/R1 So le to to L to to 1a Se L L Si L L L 11 to to fill R2X I L L R2. t. 1.. 4 R , ,9 __ L19 4 1z tr S to 1s Is to to L 17 L to fill 12 Is s is L tI 4 11 L Is R2 IA to L 1. L L So 51 al.1 to tll 15 R2 5, 15 1. L Pa15 to Si L' 1a Is to 14 L 16 t, ,R/�7 ILJ to. t. b. 15b 1 L 50 Iv' fie. St to I, So b< to to is L 1.4 I. 1. Si 5 I to is t• 4 t. to to 2 bs L 1s 1, 1.o Io \v los R7X L 1,' '4 - Isto fill o 1. Ls to too too to 10 L 15b to 1a to 4 to to 1s. L L 12. to to to L 10 5 to to L 1z to 1s to i, Ise to 4 L to So. 5.. 1.' 4 to Is L L In I,., L L X1 L to 'IA lu to 12®fill 2 +? L L Iva Ioo too to to 5LYb L 1A.2 1. 1, 1s 1R2 I. It 1s 1:t2xlaa t' 4 1R2 L 141,5 to Ft115 L 1;11115 S. So , t. to 12 s 4 IA 111 a 1• So Se t1 L So So 4 la 1, 15 to t. R2 to 1. is • 1♦ L L to I, to 0 4 L to to 1a S, 1. So 1' is L L to 1s R2 1. It 1., //rye L So R2 to to fill t1 Se / fill 11.5 1, to 12 fill 1• Stasis--2 HOUR QVESSIDf1. Is Is X� P2X 517g tut. R2X1e le I, I a L e L to 4 4 Is L �,R21i t/' ` sS. ®15L 25.74I HOUR OVERRIDE L 1., I, to to S. t / 4 1g4 IiR 1+ /J/Ri to L 1.7/R1 Sty L to 1SLV Sit Ir In t, ®17 R2 t., 4 to L to R2X L to to LIl to o la to to to to L tg 1. Is L 11 L L t 4 te L Is L 1. to L L 4 to L IA 4 1. Is to to to to L 1. 4 1. R IL MI 19 V1 1• L 10 4 L So So L L L t, to Se to to to to 4 L I R2 L L t L_-qi L to Is Is fill to to 14 to to 4 la to L to to So le tots 4 R2_ ,. 4 is R2x L R2 1 1, R2 19 19 I�(�19 to l.1 l♦ l: t t L f. 4 to C� 4 to L L to to L to to to to to to ., L L fill 4 to 1, la to Is Is L L L to to to 4 to to to L to 4 Is 14 L 1i 4 4 L 4 L L to L to 4 to 4 L 4 'la to L L L L L 4 4 I. to 4 la R2 4 Lila L L R2. R R 1 1 L to S 1 �(�19 19 (�19 1919 is to 5 t to 5a * I 1 1 1 l 4 to x1 4® j'li 4 S. 1.e Is L to to to to to I, 4 Is Is 1a to S. to S. 13 L to to In to Ss to 1, I, 11 to II to 1a 4 So R2X R2 R2 rR22---�1 Xi to/R1LQ%Ei11%/R1n_1Yi/R1 117/R1 to o to to L1 tI7 L 1, a . L 4 1'1. ,, t 2 HOUR > OVERRIDE---a-al 4 to to L 10 1. L 4 L Se to L to I. L to L to 1.1 to la .. 5a is L to to to Si R2 R2 19 19 1 " to to to Si to Ills 1, L to 1s S. to to L L L 1s 1, L to L L �R-22� II--R2 R2X rR22� R2X R2 to to E113//Rta�i)/R1t'1 1IVOti"raiil 17/R1 Se : to 1, L L L to 4 fills L L fill Sr L to R2 R2 13 13 R2 VU 13 1 R2 19 R2 R2 9 9 R2 to to 17 So to L Io L 11 11 to to Si to to L Is Si fill. L R2 R2 to by to 1e to Ie ♦ Is a Is 1. Ia . to to 1a 15i.•Ia . to L Is 1'7.//RR tr is L Si L to is 17 L R2 xmq 19 4 L 13 19 19 R2 919 19 is Is 10 17/R1'0 Ir I, I. fill, S. L Is So Sr t. fir L to R2X R2 L is to fill L OVEIARRIDE: :j>r: :A 211 211,:ovriito R: opyRi 8 Ito R2 L L 1017+/R11. So R2 so 17/R1t• S. to to 11 1, Si L to 10 to to L to L R2X R2 to ta R2 to tr 4 15 to Is So So 12 ® 1e 1.o to 1R2 ' is is L 1e 15 1, 4 to IIto to 1. L So 5o R2 1s t, IC415 So to to . to to S.r is L So Is R2 R2 t, to is 4 14 5P25. to 4 1 Ri to Is to to to to Si to 4 t. to R2X to to to 11:1813X1:1 Ste 110 to to to la la la to 1.4 lot tr to le Ss 19 19 R3 14141 13 R3 to to R211 to 10 to 11. total ts, 11 to R2X 9 19 R2 2ND FLOOR EAST LIGHTING CALCULATION PLAN to le Sly RI to Is Is to toR1 Is to te la Is 12 11 1.1 if la I la la to 1943 to. So to lo le to to to le 10 tfl to to to to to la St 14 it to to to to to a So so to t. • too o 13 to 14 ▪ ts to to to to itto 10 SO to R2 R2 19 19 15 6 15 15 L 4 ....... .... '.'.':. ....... 150to. 15a 5, I 150 s 3ye 15a t, te tA Is Ita to t V 15 to R2 It to to Is la Is o to te So Pr 1, to Roz lt to le it to RZX %a 15b 1;711ab to t. to to to to is is is SW L to Fab HOUR tOVERRIDE to to to So to to 411.4 15 0 to to to to ts to to 12 to 17 x imp R2 19 19 19 19 19 15 15 R2 15 2 HOUR OVERRIDE 14 14 to to to to to to 10 11 11 IS 1.4 R2 R2 Sys 15 15 15 15 15 15 15 Tna X1 R2X R2 19 14 to to 13 ts • 15 fool IS Is to to to Is lo to Is to So Se le to ts to 19 19 19 19 19 19 19 alrIo Walk R2 R2 • • • to is Ss iz So is to in to to to Is Is Is to So St 14 11 13 Iv So le to tt In 12 14 Iv So 14 le Is to 11 to to ta ts to is 13 is to to to 17 lo R2 1e to is a la to to I to te to Is R2 127419 iszp 19 19 19 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min °NORTH KEYPLAN EL19-0949 PRECISION ELECTRIC GROUP 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 CASE or ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. TulcwIla, WA CONSTRUCTION DEVELOPMENT City of Tukwill SPACE FOR OFFICIAL CITY USE ONLY 2ND FLOOR EAST LIGHTING CALCULATION DATE CHECKED BY PROJECT NUMBER 11/11/2019 TN 19256 EL.X3.2E A RECEIVED CITY OF TUKWILA PERMIT CENTER O SABA 2 Nickerson Street Suite SQOttle, WA TU-1-I L_J 1 ST FLOOR WEST POWER PLAN FSD 2 581-35 SCALE: 1/4' = 1'-0" EWH-1-1 FCU-1-1 FCU-1-2 NORTH GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL P2A UNLESS OTHERWISE NOTED. 2. REFER TO THE MECHANICAL EQUIPMENT CONNECTIONS SCHEDULE, SHEET EO,2, FOR ADDITIONAL INFORMATION. FLAG NOTES RELOCATED EXISTING MECHANICAL UNIT. PROVIDE LABOR AND MATERIALS AS REQUIRED TO INTERCEPT EXISTING FEEDER AND EXTEND TO LOCATION SHOWN. AS —BUILT CIRCUIT. PROVIDE CONNECTION TO FIRE ALARM PANEL AS REQUIRED. KEYPLAN ELi 9-0949 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone:425-823.8600 Fax: 425-823-8655 E CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT D C REVL IANC FFCC COMPLIANCE wl- NFPA C - 412G City of wila L34JLOING DNTukISIOr'• SPACE FOR OFFICIAL CITY USE ONLY B 1ST FLOOR WEST POWER PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 E4.1W A RECEIVED CITY OF TUKWILA NOV 1 4 2019 1 2 3 4 PERMIT CENTER SABA 01 January, 2000 TU-2-01 TU-2-13 ®-a LJ TU-2-12 L_J TU-2-02 TU-2-03 �gl ®-a LL TU-2-14 �1il -a LJ TU-2-26 L _ J TU-2-11 TU-2-10 Ill-2-09 712 L _l TU-2-20 TU-2-08 N-2-24 2ND FLOOR WEST MECHANICAL CONNECTIONS PLAN TU-2-19 TU-2-04 TU-2-15 TU-2-16 n20 Is -a L_J TU-2-17 TU-2-18 MSWBO-6 0 1 P7-22,24,26�,--y 1 L -l*RP-1] C`®) P8C-40 (S EWH-2-2 SCALE: 1/8" = 1'-0" CIRCUIT NUMBERS PREFIX: PANEL: 'P6' P6 (208V) 'PEA' P6A (208V) 'P661' P6B (208V) 'PBC' P6C (208V) 'P6D' P6D (208V) 'B1' SB1 (208V) '62' SB2 (208V) '63' SB3 (208V) 'B4' SB4 (208V) FLAG NOTES GENERAL NOTES RELOCATED EXISTING MECHANICAL UNIT. PROVIDE LABOR AND MATERIALS AS REQUIRED TO INTERCEPT EXISTING FEEDER AND EXTEND TO LOCATION SHOWN. AS -BUILT CIRCUIT. 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL P9 UNLESS NOTED OTHERWISE. NORTH TU-2-28 KEYPLAN ELi 9-0949 2 Nickerson Street Suite gSgeaittlle, WA 2060957 6400 www.sabarch.corn PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone:425-823.8800 Fax: 425-823-8655 E ClikPir CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax:425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT O C RE !COMPLIANCE A.7 S1FYC - FI G ,. i ... �. es'Li: City of Tukwila BUILDING DIVISION I SPACE FOR OFFICIAL CITY USE ONLY 2ND FLOOR WEST MECHANICAL CONNECTIONS PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 B E4.2W A RECEIVED CITY OF TUKWILA NOV 1 4 2013 PERMIT CENTER 1 SABA. 2 Nickerson Street Suite Seattle, WA E E E D C B 1L co 3 w N N N U IL w LJ ii TU-2-25 TU-2-05 TU-2-06 TU-2-23 25 CFO FCU-2-1 L _ 1 9134-40.42 FCU-2-2 5B4-40,42 TU-2-21 r2j, CO-® TU-2-07 1U-2-27 I23 .-0 L TU-2-22 2ND FLOOR EAST MECHANICAL CONNECTIONS PLAN 7P-2B-04 P8C-19,(19) P8C-19,(19) SCALE: 1/8" = 1'-0" CIRCUIT NUMBERS PREFIX: PANEL: P6 (08V) ' P6A' P6AP6 (2208V) 'P6B' P6B (208V) 'P6C' P6C (208V) 'P6D' P6D (208V) '61' SB1 (208V) '62' SB2 (208V) ' B3' SB3 (208V) 'B4' SB4 (208V) '65' SB4 (208V) 'P8' P8 (208V) ' P8A' A ((208V) 'P86' P8PSB 208V) ' PSC' P8C (208V) GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL P9 UNLESS NOTED OTHERWISE. NORTH a KEYPLAN ELi 9-0949 98 0957 6400 www.sabarch.com PRECISION ELECTRIC GROUP 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8855 CASE Pr ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT REV'IEWc FOS ! COMPLIANCE WITH• NFPA 70-NEC City of Tukwila BUILDING DIVISION ? SPACE FOR OFFICIAL CITY USE ONLY E E E D 2ND FLOOR EAST MECHANICAL CONNECTIONS PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 C B E4.2E A RECEIVED CITY OF TUKWILA NOV 142Ol9 PERMIT CENTER 1 2 3 4 5 6 SABA 2 Nickerson Street Suite Seattle, WA 1 EF-3 w P5D-2 SBD-8.10,12 CU-1 PBD-2 N3R L i 581-39,41 L r ANU-1 -- lj AISNBD-2 N3R J ROOF WEST MECHANICAL CONNECTIONS PLAN SCALE; 1/8" 0 1'-0" IHRP-2) P5B-37,39,41 EF-2 r L � 'P5B-32,34,36 R EF-1 -P8D-2 wp r r tl P58-37,39,41 I J L j P58-26,28,30 N3R HRP-1 NORTH 1 LeCj W W N cn KEYPLAN ELi 9-0949 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 E tCASE iir ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone:425-402.9400 Fax: 425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT D C I COMPLIANCE h; NFPA D -WEC h Ctty of Tukwila : BUILDING DIVISION SPACE FOR OFFICIAL CITY USE ONLY ROOF WEST MECHANICAL CONNECTIONS PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 E4.RW B A RECEIVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER Y SABA 2 Nickerson Street Suite &Kittle, WA 01 January, 2000 CU-2 P8C-42 WP SB4-40,42 R ROOF EAST MECHANICAL CONNECTIONS PLAN SCALE 1/8" = 1'-0" NORTH KEYPLAN ELi 9-0949 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 E CASE lir ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Sulte 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT .,�.:1;evi srvi.pp FCFf compANCE WIT LIH I Clty of Tukwib, 'UILDING DIVISION E E D SPACE FOR OFFICIAL CITY USE ONLY ROOF EAST MECHANICAL CONNECTIONS PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 C B E4.RE A RECEIVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER 1 2 3 4 5 6 Z v r� SABA 2 Nickerson Street Suite Settle, WA E E D C B 01 January, 2000 1ST FLOOR WEST LOW VOLTAGE PLAN SCALE: 1/4" = 1'-0" a a a 'ELEY' i111G 0 NORTH GENERAL NOTES 1. PROVIDE DATA DROPS AS SHOWN. KEYPLAN ELi 9-0949 9060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8800 Fax: 425-823-8655 E CASE ENGINEERING Consulting Electrical Engineers 19515 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT .:1p0/PLIAN CE lM City or 7uk'aril;. ij JIL ?' iG UIVISIOi" SPACE FOR OFFICIAL CITY USE ONLY E E D 1ST FLOOR WEST LOW VOLTAGE PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 E5.1W C B A RECEIVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER 2 3 4 5 6 L I J 4 SABA 2 Nickerson Street Suite SUOttle, WA 01 January, 2000 —._._._._ _._.. ._, ens ._._._._._._._._._._I_._.min _._._._._._._._oil COPIER 1 I I i i i 1 I I I I I I I I I 4 1 I I I jo�.._._._._._._._._ 4 I I I I I I I I i I I I I I i i 2ND FLOOR WEST LOW VOLTAGE PLAN SCALE: 1/6" = 1'-0" FLAG NOTES Imo ._._._._._._._._._._._._._._._._._._._,_. awn _._._._._...o CEILING PANEL. PROVIDE DATA DROP QUANTITY SHOWN FOR EQUIPMENT BELOW. +48. COPIER GENERAL NOTES 1. PROVIDE WIREMOLD 3000 SERIES WITH DATA EVERY 24" ON CENTER. 4 I I I I I I I I NORTH U KEYPLAN ELi 9-0949 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 E litirCASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA 0 C CONSTRUCTION DEVELOPMENT GREVIEVitz O:MPL,A NCE LN!,n k^c� e. P!wC ;A '>1 LMwile uuan!NG oviSIOi': SPACE FOR OFFICIAL CITY USE ONLY 2ND FLOOR WEST LOW VOLTAGE PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 B E5.2W E5.2W A RECEIVED CITY OF TUKWILA NOV 142019 PERMIT CENTER 1 3 4 5 6 SABA' 2 Nickerson Street Suite S&ttle, WA 01 January, 2000 NN W 4P II II II II II II II II II II II II II N N N SI Zren a +60" o �3 4j®[12] I. 1(E) I !Iva] <21(E) 41(E) le[6] I I 9 I l®[4] Qi PRINTER a PRINTER PRINTER (E) m S© ®© ©S & m S (i © z 0 S m m (01> © ®® © © ®® 2ND FLOOR EAST LOW VOLTAGE PLAN gi+60" wart> aCOPIER t (E) (E) (E) (E) 88 88 o �) (E) (E) ® 8 +60"p wpprt> +60 0 [6)©I iffiV ICOPIER (E) (E) (E) (E) 8 8 I 4(E) 4(E) (E)> 4(E) (E) (E) (E) (E) (E) (E) (E) (E) 8 8 W W W W WW C (E)® SCALE: 1/8" = 1'-0" FLAG NOTES CEILING PANEL. PROVIDE DATA DROP QUANTITY SHOWN FOR EQUIPMENT BELOW. GENERAL NOTES 1. PROVIDE WIREMOLD 3000 SERIES WITH DATA EVERY 24" ON CENTER. NORTH KEYPLAN ELi 9-0949 200957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC ✓� 15323 NE 90th Street Redmond, WA 98052 Phone:425-823.8600 Fax: 425-823-8655 E CASE Pr ENGINEERING Consulting Electrical Engineers E 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT E D C Y F:EVIEF CDAV:ANCE MPPA7C"N 21. City of Tukwila GUILDING DIVtSION SPACE FOR OFFICIAL CITY USE ONLY 2ND FLOOR EAST LOW VOLTAGE PLAN DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 B E5.2E A RECEIVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER 1 2 3 4 5 6 SABA 2 Nickerson Street Suite BSg&6tt!le, WA 2060957 6400 P4B 60 P4A P4 15INA UPS T-P48 75 WA XFMR T-P4 75 WA »MR I PBD P6C PBB ! i I UPS RISER DIAGRAM NOT TO SCALE P3 200 PEA P6 T-P6B 75 WA XFMR T-P8 75 WA XFMR P58 P5 BUILDING B (SCOPE OF WORK) P2B P P2 T-P2B 75 kVA XFMR P1 P1B ACU-1 ACU-2 P7B ELEVATOR MDP 2000A 480Y/277V 30, 4W MOP (E) 2000A � /27 57,426I T-PBC 75 kVA XFMR T-P8 75 WA XFMR 3"C. 4#500KCMIL AL & 112 AL GND INC 200 PM P6 P8B EF-3 3/CC.-Vs Cu & 1j110 Cu GND SBD (N) 300A 480Y/277V 30, 4W T-S85 30kVA XFMR -01 1/0 Al. 1 1/2"C.-4/1 AL & 1#6 AL GND- -2 1/2"C--3#250KCMIL AL & 114 AL GND 9,768 Xr- 20,834 MSWBD DISTRIBUTION (N) 480Y/277V 30, 4W MSWBD C/r INCOMING 3bObA 480Y/277V 30, 4W 1-(5)4"C.-4/750KCMIL AL & 1j400KCMIL AL GND --! 63,469 NEC_ I702 LE (N) 150 WA XFMR CC-4#1 AL & 116 AL GND SBOL I/O AL SB1 5B2 (2)2 I/2"C. 4#250KCMIL Al. & Ij1/0 AL GNO 300A7 40040A/ (N) SB3 -3"C.-4/500KCMIL AL & 1j2 AL GND 300A SB4 LEGEND ■ SB6 SB5 1,788 EXISTING FEEDER SIZE IN AMPS SCUD SHADING IN HEAVY LINES INDICATES NEW EQUIPMENT. PARTIAL SHADING IN LIGHT ONES INDICATES EXISTING EQUIPMENT BEING MODIFIED. X---J32,500 AVAILABLE FAULT CURRENT (IN AMPS) (E) SCL 1500KVA XFMR j \ --(8)4"C. 4#750KCMIL AL TO SCL NETWORK FLAG NOTES e NEW MSWBD (NOTE 1) PROJECT NAME: CELLPETIX PROJECT 4. 19268 LOCATION: TUKWILLA WA FED FROM NOTE CKT NO. CIRCUT NAME 8 CB SIZE LOAD (KVA) AMP P R H M L K 0 TOTAL PANE. DESCRIPTION 2 1 MOP A 1900 3 __ __......_. __. � PANEL AMPS FEEDER AMPS : : : : : x - j( 4000 3000 480 277 3 4 - B - .. - C - - L -L VOLTS: 2 AH -1 A 400 3 108.6 106.6 L - N VOLTS - B - - 108.6 108.6 PHASE - C - - 108.6 108.6 VMRE 3 SBD A 300 3 14.5 12.5 11.0 18.2 26.5 82.8 - B - - 10.4 142 8.6 15.8 30.6 79.8 - C - - 9.3 174 5.3 8.5 25.4 66.0 4 SPARE A 1000 3 M.L.O. MAN CB - C - - FLUSH 5 PARE A 600 3 SURFACE - B - - ISO GND - C - FEEDhIHRU 6 EVU+2-1 A 150 3 30.0 30.0 - B - - 30.0 30.0 - C - - 30.0 30.0 LOAD SUMMARY ( TOTAL,ALL SECTIONS I REM KVA : 34.3 FEAT KVA ; 90.0 MOTOR KVA : 369.9 LIGHTNG KVA : 24.9 KITCHEN KVA : 42.6 OTHER KVA : 82.4 PNASEA KVA : 221.4 AMPS : 799.1 PHASES KVA : 218.2 AMPS : 787.6 PHASE KVA : 204.5 AMPS : 738.4 CONNECTED LOAD KVA : 644.1 AMPS : 774.7 DEMAND LOAD KVA : 661.0 AMPS : 795 1 NOTES$EQAR(S: 094AND1 DIVERSITY FACTORS 1. SHOWN 2. LSIG 3. 4. 6. 6. FOR REFEFENCE ONLY, SEE LOAD CALC BREAKER LOAD DESCRPTION DEMAND R RECEPTACLES -TO 10KVA 100% = 10.0 REMANNG OVER 10KVA 50% = 12.1 H HEATNG 100% = 90.0 M MOTORS 100% = 261.3 LM LARGEST MOTOR 125% = 135.7 LM LCFITNG 125% = 31.1 K KITCHEN 90% = 38.3 0 OTHER 100% = 82.4 3 DEMAND SUMMARY Project: CELLNETIX MDP 2000A SWBD Job Number 19256 Voltage: 480 Volt Phase: 3 0 Existing Peak Demand: (12-MONTH UTILITY BILLS) Code Multiplier (NEC 220.87) LEO ASTELLAS New Load: PANEL P1 PANEL P2A/P2 PANEL P5/P5B PANEL P6B/6C/6D PANEL P6AIP6 PANEL P7IP7B PANEL P8CIP8 PANEL P8A/P8B Total new load added: Total new Demand Load: 1.25 394.76 kVA 493.45 kVA 705. kVA 50.5 kVA 11.4 kVA 2.53 WA 43.22 WA 32.7 kVA 2.39 kVA 39.28 kVA 36.42 kVA 218.43 kVA 1416.88 kVA 1704 Amps (480V) MATCH AIC RATING OF PANEL Pa. DEMAND SUMMARY Project: CELLNETIX MDP 3000A MSWBD Job Number. 19256 Voltage: Phase: New Load: MDP PANEL SBD 480 Volt 30 Total new load added: Total new Demand Load: 1416.88 kVA 213.81 kVA 1630.69 kVA 1630.69 WA 1961 Amps (480V) KEYPLAN RECEIVED CITY OF TUKWILA JAN 10 2020 PERMIT CENTER ELi 9-0949 EL1% o,q CORRECTION LTR#__1.. www.sabarch.corn PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax:425-823.8855 CASE Pr ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax:425-402.9402 REVISIONS: A I \ MECHANICAL CHANGES 11-13-19 .4 \ LIGHTING CHANGES 11-21-19 TUKWILA COMMENTS � 12-19-19 /4\ TUKWILA COMMENTS 1-10-2020 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT r iI 00WFPA,7G-&ccT City ofTukt�,ils i!IJILDING DIVISION L J SPACE FOR OFFICIAL CITY USE ONLY RISER DIAGRAM AND DEMAND SUMMARIES DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 E9.1 I 1 2 3 4 PANEL 'ELEV' FRO.ECF MANE: PROJECT*: LOCATION: FED FROM: PANG P2A NOTE CKT NO CIRCUT NAME CB SIZE LOAD (KVA) PANE- DESCRIPTION a AMP P R H M L K 0 TOTAL 1 REC - B.EV PR A 20 1 0.2 0.2 PANEL AMPS : : : : - 60 60 208 12[ 1 3 10K 3 REC -IAE B 20 1 0.2 0.2 FEEDER ANPS: L- L VOLTS L- N VOLTS PHASE: VASE A.LC.: M.L.O.'_X MAN W_ FLUSH SLRFACEX_ SO GND FEED-THRU 5 SPARE A 20 1 7 SPARE B 20 1 9 SPACE A - 1 11 SPACE B - 1 13 SPACE A - 1 15 SPACE B - 1 17 SPACE A - 1 LOAD SUMMARY (TOTAL. ALL SE C TUNS I RED KVA FEAT KVA MOTOR KVA : 0.4 : : : 0.3 : : : 0.5 : 3.9 : 02 : 1.8 1.8 2 LTS-ELEVATOR CAB A 20 1 0.2 0.2 4 LTS - ELEV ROOM B 20 1 0.0 0.0 6 LTS - B-EV PIT A 20 1 0.1 0.1 8 SPARE B 20 1 LIGHTING KVA 10 SPACE A - 1 KITCHEN KVA 12 SPACE B - 1 OTHER KVA 14 SPACE A - 1 16 SPACE B - 1 PHASE A KVA 18 SPACE A - 1 AMPS PHASE B KVA AMPS CONVECTED LOAD KVA : 0.7 : 3.2 AMPS CESAND LOAD KVA : 0.8 : 3.6 AMPS NOTES/RE A ARKS : 1. 2. 3. DOA AND I DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES -TO 10KVA 100% = 0.4 RBIANNG OVER 10KVA 50% = H HEATNG 100% = M MOTORS 100% = LM LARGEST MOTOR 125% = L LIGHTNG 125% = 04 K KITCHEN 100% = 0 011-82 100% = (E) PANEL'P6A' (SECTION 2) FRO,ECT NAME CELLNETIX PROJECT#: 19268 LOCATION: TLKIMLLA WA FED FROM: PANEL F6 CKT CIRCUIT NAME CB SIZE LOAD (KVA) NOTE NO.6 AMP P R H I M L K 0 TOTAL PANEL DESCRIPTION 1 1 REC - RESTROOM A 20 1 0.5 ... 0.5 PANEL AMPS : 225 .... T T- NATFIR FOUNFA N --- --'-- B 20 1 "-- 0.1 0.1 FEE3)EL-R AMPS : 200 1 VAV CONTROL C 20 1 0.1 0.1 L - L VOLTS : 208 1 7 FI:SMOKE DANCERS A 20 1 0.2 0.2 L- N VOLTS : 120 1 9 REC- ROOF B 20 1 0.4 0.4 PHASE : 3 2 11 RED - MOTHERS RM C 20 1 0.4 0.6 1.0 CORE : 4 2 13 RED- OFFICES WEST A 20 1 1.4 1.4 2 15 WREVOLD- ACCESSIONNG B 20 1 0.4 04 2 17 CELNG PANE_ -ACCESSDNNG C 20 1 0.4 0.4 M.L.O. X 2 19 WREMOLD- ACCESSONNG A 20 1 0.5 0.5 MAN CB 2 21 CEL NG PANEL - ACCESSIONNG 8 20 1 04 0.4 FLUSH 2 23 REC- OFFICES WEST C 20 1 14 1.4 SURFACE X 25 SPARE A 20 1 SO GND 27 SPARE B 20 1 FEED•THRU- 2 29 REC-COFFEE GP C 20 1 0.7 0.3 1.0 2 31 REF - COFFEE A 20 1 0.8 0.8 2 33 DEPOSER/OW - COFFEE B 20 1 1.8 1.8 2 35 MW-COFFEE C 20 1 1.5 1.5 2 37 COFFEE -COFFEE A 20 1 1.5 1.5 LOAD SUMMARY 39 SPARE B 20 1 (TOTAL,ALL SECTIONS 41 SPARE C 20 1 2 2 WIREAOLD-EMBBDDNG A 20 1 0.5 0.5 RED KVA: 13.5 2 4 AIRBAOLD - EMISSCONG B 20 1 0.5 0.5 HEAT KVA : 2 6 CELNG PANG- ACCESSIONING C 20 1 0.4 0.4 MOTOR KVA : 0.3 2 8 WREMOLD-ACCESSIONNG A 20 1 0.9 0.9 LIGHTNG KVA : 2 10 CFLNG PANEL - ACCPARIONNG B 20 1 0A 0.4 KITCHEN KVA : 6.2 2 12 CEL NG PANEL -ACCESSIONING C 20 1 0A 0.4 -OA OTHER KVA: 2.2 2 14 AUTODOOR - FROCESSNG A20 1 0.4 2 18 REC -FROCESSNG B 20 1 02 0.2 PHASEA KVA : 8.1 2 18 VIREhOLD-SPECIALS C 20 1 0.9 0.9 AMPS: 87.3 2 20 WIRBrOLD-AL1.SSONNG A 20 1 0.9 0.9 PHASES KVA: 5.0 2 22 CEL NG PANEL - SPECIALS B 20 1 0.4 04 AMPS: 41.3 2 24 CEL NG PANEL -PROCESS C 20 1 0.4 04 PEASE KVA: 9.2 28 SPARE A 20 1 AMPS : 78.3 28 SPARE B 20 1 2 30 CELNG RANG-STANNG C 20 1 0.4 0.4 2 32 CELNG PANEL - STANNG A 20 1 0.4 0.4 CONNECTED LOAD 2 34 REC- CLOSET/STORAGE B 20 1 0.5 0.5 KVA : 22.2 2 36 CRY° - HISTOLOGY STORAGE C 20 1 14 1.4 AMPS: 61.6 38 SPARE A 20 1 DEMAND LOAD 40 SPARE B 20 1 KVA : 18.7 42 SPARE C 20 1 AMPS : 51 8 NOTES/REMARKS : DEMAND I DIVERSITY FACTORS 1. EXISTING LOAD. LOAD DESCRIPTION DEMAND 2. NEW LOAD. 3. R RECEPTACLES-TO10KVA 100% = 10.0 REMANNG OVER 10KVA 50% = 1 7 H HEATNG 100% = M MOTORS 100% = 0.1 LM LARGEST MOTOR 125% = 0.3 L LIGHTNG 1259E = K KITCHEN 70% = 4.3 0 OTHER 100% = 22 (E) PANEL 'P2' (SECTION 2) FRO.ECT NAME CELLNETIX PROJECT*. 19256 LOCATON: 1U(1MLLA WA FED FROM P2A CRT CIR CUT NAME CB SIZE LOAD (KVA) NOTE NO. a AMP P R H M L K 0 TOTAL PANEL DESCRIPTION 1 1 REC-CORE LOBBY A 20 1 0.7 0.7 PANEL AMPS : 225 1 3 REC-CORE LOBBY 6 20 1 0.7 0.7 FEECERAMPS : 200 1 5 LIGHTNG CONTACTOR C 20 1 0.2 0.2 L - L VOLTS : 208 1 7 FACP A 20 1 0.5 0.5 L -N VOLTS : 120 1 9 REC- RESTROOMS B 20 1 0.4 0.4 SASE 1 3 1 11 REC- CRNKNG FOUNTAN C 20 1 0.6 0.8 WRE : 4 1 13 REC- C A 20 1 0.9 0.9 1 15 REC -N B 20 1 0.9 0.9 1 17 REC -C C 20 1 0.9 0.9 M1.0. X 1 19 REC -N A 20 1 09 0.9 MAN CB_ 1 21 REC-N B 20 1 0.9 0.9 FLUSH 1 23 REC-N C 20 1 0.9 0.9 SURFACE X 1 25 REC-C A 20 1 09 0.9 60 GND 1 27 REC- N B 20 1 0.9 0.9 FEES -THRU _ 1 29 RE' -N C 20 1 0.9 0.9 1 31 REC -N A 20 1 0.9 0.9 1 33 COPER-RMW-120 B 20 1 1.5 1.5 1 35 REC - N C 20 1 04 0.4 1 37 SFD A 30 3 LOADSUMMARV --,a - B - - I TOTAL. ALL SECTIONSI 41 - C - - 1 2 REC A 20 1 0.9 0.9 REC KVA : 19.1 1 4 RED REC B 20 1 0.9 0.9 HEAT KVA : 3.0 1 6 LTS- ELEVATOR CAB C 20 1 0.1 0.1 MOTOR KVA : 3.5 1 8 LTS- ELEV MACHNERM A 20 1 0.2 0.2 LIGHTNG KVA : 0.3 1 10 REC-ELEVATORPIT B 20 1 0.4 0.4 KITCHEN KVA: 1 12 VAV CONTROL C 20 1 0.5 0.5 OTHER KVA : 4.7 1 14 RRGATCN CONTROLLER A 20 1 0.5 0.5 1 16 REC-C B 20 1 0.9 0.9 FHASEA KVA : 11.5 1 18 COPER C 20 1 1.5 1.5 AMPS : 95.9 1 20 RED-C A 20 1 0.9 0.9 PHASEB KVA : 10.0 ' 1 22 REC -N B 20 1 0.9 0.9 ANDS: 83.8 1 24 REC- POWER POLE EAST SCE C 20 1 0.9 0.9 PHA,SEC KVA: 9.1 1 26 TRIB-18,.17 A 20 1 1.1 1.1 AMPS : 75.7 1 28 REC- C B 20 1 0.7 0.7 1 30 RE- C C 20 1 0./ 0.7 1 32 am- lEXHAUST FAN A 20 1 1.6 1.6 CONNECTED LOAD 1 34 CRCPUvP B 20 1 0.2 0.2 KVA : 30.8 1 36 WATER HEATER C 30 2 1.5 1.5 AMPS : 85.0 38 - A - - 1.5 1.5 DEMAND LOAD 1 40 REC B 20 1 0.7 0.7 KVA : 28.5 42 SPARE C 20 1 AMPS : 733 NOTES/REMARKS : DEMAND / DIVERSITY FACTORS 1. EXISTING LOAD LOAD CESCRPTION CBAAND 2. NEW LOAD 3. R RECEPTACLES -TOI0KVA 100% = 10.0 REMANNG OVER 10KVA 50% = 4.5 H HEATNG 100% = 3.0 M MOTORS 100% 2.0 LM LARGEST MOTOR 125% = 2.0 L LGHTNG 125% = 0.4 K KITCHEN 100% 0 OTHER 100% = 4.7 (E) PANEL 'PS' (SECTION 1) PROJECTNAME: CILLNETIX FROJECr#: 1928E LOCATON: TUKWILLA WA FED FROM: PANG PS VIA XFMR CKT CIRCUIT NAME CB SIZE LOAD (KVA) NOTE Na e A• P R H M L K 0 TOTAL PANEL DESCRIPTION 1 1 REC- RESTROOM A 20 1 0.5 0.5 PANEL AMPS : 225 1 3 WATER FOUNTAN E 20 1 0.1 0.1 FEEDER AMPS : 200 1 5 VAV CONTROL 20 1 07 0.1 L -L VOLTS : 208 1 7 FRE SMOKE DAMPERS 999 20 44 0.2 0.2 L - N VOLTS : 120 1 9 REC- ROOF 20 jJ PHASE : 3 11 SPARE 20 WI7E : 4 13 SPARE 20 .... 15 SPARE 17 WREMOLD-GROSSNG 20 1.1 1.1 M1.0. 2 19 WREMOLD- FROCESSNG 20 0.5 0.5 MAN C8 X 200A 2 21 CRY 0-EMBECONG 20 1.4 1.4 FLUSH 1 23 SPD 30 SURFACE X 25 - - BO GND X 27 - - FfffiTHRU 2 29 EOUIFMBNT - EMBEDONG 20 1.1 1.1 TO PANEL F6 2 31 EQUIPMENT-EMSECONG 20 1.1 1.1 2 33 EOUPMBNT-EMBED:MG 20 1.1 1.1 35 SPARE 20 37 SPARE 20 LOAD SLUT MARY 39 SPARE 20 (TOTAL. ALL SECTIONSI 41 SPARE 20 2 2 REC -TELEPHONEUNISBQHALL a 20 0.1 0.7 REC KVA : 19.9 2 4 REC- OFFICE WEST = 20 1.4 1.4 HEAT KVA : 2 8 REC - CONFERENCE WEST 20 1.1 0.3 1.4 MOTOR KVA : 0.6 SPARE 20 LIGHTNG KVA : ........ SPARE _ 20 KITCHEN KVA : 6.2 SPARE 20 OTHER KVA : 8.2 SPARE A 20 18 SPARE 20 1 PHASEA KVA : 11.5 18 SPARE 20 1 AMPS : 95.7 20 SPARE 20 1 FHASEB KVA : 9.4 22 SPARE 20 1 AMPS : 78.2 2 24 COPIER - ACrEASDNING 20 1 0.8 0.8 PHASE C KVA : 14.0 26 SPARE 20 1 ASPS : 116.7 28 SPARE 20 1 2 30 CELING PANG- ACCFRSIONNG 20 1 0.4 0.4 32 SPARE 20 1 CONNECfEDLOAD 34 SPARE 20 1 KVA : 34.9 38 SPARE 20 1 ANDS : 96.8 2 38 CELING PANEL-ACCESSIONNG 20 1 0.4 0.4 CaAANDLOAD 2 40 CELING PANEL -ACCESSIONNG 20 1 0.4 0.4 KVA : 28.1 78.0 42 SPARE C 20 1 AMPS : NOTES/REMARKS : DEM ANC/ DIVERSITY FACTORS 1. EXISTING LOAD. LOAD DESCRPTON DEMAND 2. NLANL OA D. 3. PROVIDE CIRCUIT BREAKER INDICATED. R REBCEPTACLES- TOIOKVA 100% = 10.0 RIMMING OVER IOKVA 50% = 5.0 H HEATNG 100% = = 0.4 M MOTORS 100% LM LARGEST MOTOR 125% = 0.3 L LIGHTNG 125% = K KITCHEN 70% = 4.3 0 OTHER 100% = 8.2 (E) PANEL'P2A' (SECTION 1) FROECT MANE cELLPET1x FRO,ECT#. 19268 LOCATON: TUKWILLA WA FED FROM:'ANB- P1 VIA VIAL NOTE 2 2 2 CKT IC. 1 CIRCUIT NAME REC - STORAGE 3 FRNTER - LBRARY 2,3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 2 4 6 AUTO DOORS DOCK LEVELER REC -C RED - N REC - C REC - C REC- N REC -C REC - N REC - C REC - N REC - C RISC-N REC -C REC - N RED-N TFIB-15 REC - STOCKROOM REC- LBRARY OFFICES RED - LBRARY COUNTER 2 2 2 2 2,3 8 10 12 14 16 1e REF- LBRARY RED - LBRARY OFFICES REC- LBRARY REC- LBRARY FLOOR PANEL ELEV 20 22 24 28 1 1 28 30 32 34 SPARE SPARE SPARE SPARE RED -C REC - C SPARE REC - COFFEE A PEA 1 1 36 38 40 42 REC - COFFEE AREA RED- W126 SPARE SPARE MOTES/RBI ARKS : 1. EXISTING LOAD. 2. NEWLOAD. 3. PROVIDECIRCLAT BREAKER INDICATED. CB SIZE LOAD(KVA) e - PR HPAL K 0 TOTAL A 20 1 0.2 20 1.0 10 1.0 09 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.7 1A 0.4 1.4 0.7 0.4 0.2 0.2 0.9 0.9 0A C 20 1 0A A 20 1 0.7 B 20 1 C 20 1 DOI MIN DIVERSITY FACTORS LOAD CESCRFION R RECEPTACLES -TO 10KVA REMANNG OVER 10KVA H HEATNG M MOTORS LM LARGEST MOTOR L LIGHTNG K KITO-BN 0 OTHER 0.2 1.5 0.2 PANS DESCRIPTION 1.0 1.0 1.0 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.7 1.4 0.4 1.4 0.7 0.4 0.5 0.7 PANEL AMPS : FEEDER AMPS : L -L VOLTS: L -N VOLTS: PHASE : WRE: ML.O. MAN C8 x 200A FLUSH SURFACE ISO GND FEED-THRU TO PANEL P2 225 200 208 120 3 4 x x LOAD SUMMARY I TOTAL , ALL SEC TO NSI RED KVA HEAT KVA MOTOR KVA LIGHTNG KVA KITCHEN KVA OTHER KVA FHASEA KVA AMPS PHASEB KVA AMPS PHASE KVA A'S 41.4 3.0 6.5 0.6 0.8 6.4 19.8 164,9 21.6 180.3 17.3 144.4 CONNECTED LOAD KVA : 58.8 AMPS : 163.1 DEMAND LOAD KVA : 44.0 AMPS : 122.0 DEMAND 100% 50% 100% 100% 125% 125% 100% 100% = 100 157 3.0 35 3.8 0.8 = 0.8 = 64 (E) PANEL 'P5B' (SECTION 2) FRO,ECT NAME CELL NETI X PROJECT* 19266 LOCATION: TUKW1LLA WA FED FROM: PANG PS CIRCUIT NAME CB SIZE LOAD(KVA) NO scKT NO. a AMPIP R H M L K 0 TOTAL PANEL DESCRIPTION 1 1 FP2B-16 A 20 3 3.2 3.2 PANE AMPS : 400 3 - B _ _ 3.2 3.2 FEEDER AMPS : 400 5 C _ _ 3.2 3.2 L- LVOLTS : 480 1 7 IP16-17 A 20 1 i 4.2 4.2 L- N VOLTS : 277 1 9 FP28-46 B 40 1 8.8 6.6 PHASE : 3 1 11 FP2B-47 C 15 1 2.9 2.9 CORE : 4 1 13 9928-19 A 25 1 5.8 5.6 1 15 FP28-18 B 20 1 42 4.2 1 17 FP2B-50 C 20 1 4.2 4.2 M.L.O.X 1 19 FP2B•52 A 20 1 4.2 4.2 MAN CB 1 21 EDH2B-52 B 15 1 2.0 2.0 FLUSH 23 SPARE 20 SURFACE X FP26-52 42 4.2 BO GND El1 SPARE I �� FTSITHRU SPARE 20 1 31 SPARE 2D 1 33 SPARE 20 1 C - 1 35 SPACE 37 HRP-1 &HRP-2 A 20 3 4.0 4.0 LOAD SUMMARY 39 - B - - 40 4.0 (TOTAL ,ALL SECTIONS I 41 - C - - 40 4.0 2 SPARE A 20 1 REC KVA : 4 SPARE B 20 1 HEAT KVA : 8 SPARE C 20 1 MOTOR KVA : 103.5 8 SPARE A 20 1 LIGHTNG KVA : 2.5 10 SPARE B 20 1 2.5 2.5 KITCHEN KVA : 12 SPARE C 20 1 OTHER KVA : 14 SPARE A 20 1 16 SPARE B 20 1 PILASEA KVA : 40.0 18 SPARE C 20 1 AMPS : 144.3 20 SPARE A 20 1 PHASES KVA: 37.2 22 SPARE B 20 1 MARS : 134.2 24 SPARE C 20 1 PHASEC KVA : 28.9 2,3 26 ff-1 A 40 3 9.0 9.0 AMPS : 104.2 a - B - - 9.0 9.0 30 C - - 90 9.0 - E -2 A 30 3 ' . 5.6 5.6 CONNECTED LOAD Iii32 - Q - - 5.6 5.6 KVA : 106.0 36 - C - 0 5.6 5.6 AMPS : 127.5 38 SPACE - 1 OBAAND LOAD 40 SPACE B - 1 KVA : 113.4 42 SPACE C - 1 AMPS : 138.4 NOTES/REM ARKS : DEMAND I CIVERSITY FACTORS 1. EXISTING LOAD. LOAD 06CRPfgN CBIAND 2. NEW LOAD 3. PROVIDE CIRCUIT BREAKER INDICATED. R RECEPfACLES - TO IOKVA 100% = REMANNG OVER 10KVA 50% = H HEATNG 100% = M MOTORS 100% = 76.4 LM LARGEST MOTOR 125% = 33.9 L LIGHTNG 125% = 3.2 K KITCHEN 100% = 0 OTHER 100% = (E) PANEL 'P1' PROJECT NAME CELLNET1X FRO,ECT it: 19268 LOCATION: TLKWILLA WA FED FROM: MOP CKT CIRCUIT NAME CB SIZE LOAD (KVA) NOTE P10 a AMP P R H M L K 0 TOTAL PANEL DESCRIPTION 1 1 LTS- WEST ENTRANCE A 20 1 1.6 - ---_. 1.6 PANG ANDS : 400 3,4 3 30HELEVATOR B 90 3 16.E 76.E FEECER APPS: 400 6 6 - C - - 16.3 18.3 L -L VOLTS: 480 7 - A - - 18.3 16.3 L -N VOLTS : 277 1 9 LTS B 20 1 3.8 3.8 PHASE : 3 1 11 LTS C 20 1 3.8 3.8 WIRE : 4 1 13 LTS A 20 1 2.8 2.6 1 15 LTS B 20 1 2.4 2.4 1 17 LTS C 20 1 2.9 2.9 1 19 FPIB-13 A 20 1 4.2 4.2 M.L.O. X 1 21 FPIB-19 B 20 1 1.7 1.7 MAN C8 1 23 FPIB-12 C 20 1 4.2 4.2 FLUSH 1 25 FB1B-11 A 25 1 5.2 5.2 SURFACER 1 27 FPIB-20, FPIB-21 B 30 1 4.0 4.0 EO GND _ 1 29 FP1B-14 C 20 1 3.6 3.8 FE -THRU_ 1 31 LTS -BNOLLARDS A 20 1 2.7 2.7 1 33 LTS -PARKNG LOT B 20 2 2.7 27 35 - C - - 2.7 2.7 3,4 37 TU-1-01 A 30 1 LOAD SUMMARY 1 39 LTS -SOUTHPARKNG B 20 2 2.7 2.7 -3.7 (TOTAL. ALL SECTIONS 41 - C - - 2.7 1 2 HAT A 30 1 4.5 4.5 REC KVA : 41.4 3 4 SPARE 8 20 1 1.5 1.5 HEAT KVA : 35.8 1 8 MOF AC UNIT C 25 3 3.8 3.6 MOTOR KVA : 124.4 8 - A - - 3A 3.6 LIGHTNG KVA : 32.8 10 - B - - 3.6 3.6 KITCHEN KVA : 0.8 1 12 FP1B-2 C 30 1 5.9 5.9 OTHER KVA : 19.7 1 14 FPIB-15,16 A 20 1 3.6 3.6 1 16 FP1B-17,18 B 20 1 34 3.4 P ASEA KVA : 88.4 1 18 FP1B-22,23,24 C 30 1 3.9 3.9 AMPS : 319.3 1 20 FPIB-1 A 30 1 8.2 8:2 PHASEB KVA : 82.5 1 22 LTS-2ND FL LOBBY B 20 1 1.0 1.0 AMPS: 297.8 3,4 24 am-1-1 C 30 1 5.5 5.5 PHASEC KVA: 83.7 1 28 PANG P1B A 100 3 14.0 14.0 AMPS : 302.3 28 - B - - 12.9 12.9 30 C - _ 73 7.3 1,2 32 PANEL P2B V IA 75KVA A 100 3 4.3 4.3 CONNECTED LOAD B _ _ 4.9 4.9 KVA : 254.7 38 _ _ C _ _ 4.1 4.1 AMPS : 306.3 38 PANEL P2 (P2A) VIA 75KVA A 100 3 12.E 1.5 3.7 0.2 0.8 1.0 19.8 CEMAND LOAD 40 - B - - 17.1 1.2 0.3 3.0 21.6 KVA : 259.4 312.0 42 - C - - 11.7 1.5 1.6 0.1 2.4 17.3 AMPS : NOTES/RBA ARKS : DEMAND/DIVERSITY FACTORS 1, EXISTING LOAD. LOAD DESCRPTON DEMAND REC ORD [RAVINGS. R RECEPTACLES -TO10KVA 100% = 10.0 2. LOAD TAKEN AT100%OF 3. NEW LOA D. 4. PROVIDE CIRCUIT BREAKER INDICATED. REMANNG OVER 10KVA 50% = 15.7 H HEATNG 100% = 35.8 M MOTORS 100% = 75.3 LM LARGEST MOTOR 125% = 61.3 L LIGHTNG 125% = 40.7 K KITCHEN 100% = 0.8 0 OTHER 100% = 19.7 (E)PANEL'P5' (SECTION 1) FROJECT#: 19268 FRO,ECT NAME CELL NETI X TUCWIL LA WA FED FROM MOP LOCATION: CKT CIRCUIT NAME CB SIZE LOAD (KVA) NOTE SO. e AMPI P R H M L K 0 TOTAL PANEL DESCRIPTION 1 1 LTS-RESTROOMS A 20 11 1.2 1.2 PANEL AMPS: 400 3 SPARE B 20 1 FEEDERAMPS : 400 5 SPARE C 20 1 L- L VOLTS : 480 1 7 FP28-01 A 15 1 2.9 2.9 L - N VOLTS : 277 1 9 FP2B-02 B 15 1 32 3.2 PHASE : 3 1 11 FP2B-23 C 20 1 4.2 4.2 WRE : 4 1 13 FP2B-24 A 20 3 2.5 2.5 15 - B _ _ 2.5 25 17 - C - - 25 2.5 M.L.O. X 1 19 FP25-26 A 15 1 32 3.2 MAN CB 1 21 FP26-27 B 15 1 2.9 2.9 FLUSH 1 23 FP2B-29 C 15 1 2.9 2.9 SURFACE X 1 25 FP25-25 A 40 1 _ 6.6 8.8 ISO GND 1 27 FP2B-03 Q 20 1 4.2 4.2 FEW-THRU X 1 29 FP2B-04 20 1 4.2 4.2 TO PANE 1 31 FP29-30 ' 20 3 2.5 2.5 PSB 33 - - - 2.5 2.5 - - 2.5 2.5 35 - 1 37 FP2B-28 ' 2011 4.2 4.2 LOAD SUMMARY 39 SPARE : 20 1 ITOTAL,ALL SECTIONS 1 41 LTS - aEC RMYSTA RWEL 20 1 1.0 1.0 1 2 FP2B-20 ' 20 3 2.9 2.9 REC KVA : 40.8 4 - B - - ' 2.9 2.0 HEAT KVA: 6 C - _ 2.9 2.9 MOTOR KVA : 192.0 4.7 1 8 F82B-51 A 20 1 42 4.2 LIGHTNG KVA : 1 10 FP2B-21 B 25 1 58 5.8 KITCHEN KVA : 84 1 12 FP2B-22 C 20 1 3.2 3.2 OTHER KVA : 28.5 1 14 FP26-49 A 20 1 3.2 3.2 18 SPARE B 20 1 PHASEA INA : 102.3 20 1 3.2 3.2 AMPS : 369.4 1 18 FP2B-38 C 20 SPARE A 30 1 FHIASEB KVA: 88.0 22 SPARE B 20 1 AMPS : 310.5 24 SPARE C 20 1 PHASE KVA : 88.1 28 PANEL 68 V IA 75KVA XFMR A 100 3 7.2 8.4 15.6 AtvPS : 310.7 28 - B - - 7.9 0.5 5.2 13.6 30 C - - 5.8 2.2 6.7 14.7 1 32 ff-1 15 ..-. 2.0 2.0 CONNECTED LOAD - 2.0 2.0 KVA : 274.4 330.1 36 -- 2.0 2.0 AMPS : DEMAND LOAD 38 PANEL P6 (F6A) VA 75KVA XFMR A 100 3 7.3 0.4 -n 1.5 11.5 40 - B - - 4.9 0.2 1.8 2.5 9.4 KVA : 265.E 319.1 42 - C - - 7.7 2.1 4.2 14.0 AMPS : NOTES/REMARKS : DEMAND I DIVERSITY FACTORS 1. EXISTING LOAD LOAD CFSCRIPTION CS%AND 2. NEW LOAD 3 R RECEPTACLES -TO10KVA 100% = 100 REMANNG OVER 10K VA 50% = 154 H HEATNG 100% = M MOTORS 100% = 164.9 LM LARGEST MOTOR 125% = 33.9 L LGH7NG 125% = 5.9 K KITCIBN 80% = 6.7 0 OTHER 100% = 28.5 ELi 9-0949 SABA 2 Nickerson Street Suite SOOttle, WA 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Redmond, WA 98052 Phone:425-823-8800 Fax;425-823-8855 E •CASE ENGINEERING I Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax:425-402-9402 E F CELLN ETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT D C r L 1 mEVIT -r APJCE TE"; MFVA'70 - MEC n City of Tukwila UUILDING DIVISION SPACE FOR OFFICIAL CITY USE ONLY 1 J PANEL SCHEDULES DATE CHECKED BY PROJECT NUMBER 11/11/2019 TN 19256 B E10.1 A RECEIVED CITY OF TUKWILA 01 January, 2000 1 S 4 5 6 NOV 1 l 2019 PERMIT CENTER O 4 D O S 4\ B A 1 C. E E E D C B A 2 at LL r (E) PANEL 'PT' (SECTION 1) PROJECT NAME CELLNEUX PROJECT A. 19256 LOCATION TUIONLLAWA FEDFRCM ACP NOM CKT IC CIRCUIT NAME CB SIZE LOAD(KVA) PANG DESCRIPTION B AMA R H I M L K O TOTAL 1 SPARE A 20 3 S PANEL AMPS: : : : : _ X X I 400 400 480 277 3 4 3 6 - 8 C - - i I 4.2 2.9 FEEDBRAMPS L- L VOLTS L- NVOLTS: PHASE - - 1 7 FP23-14 _ A 8 20 15 1 1 4.2 2.9 - 1 9 FP2B43 F- I 1 11 FP2B-32 C 20 1 4.2 4.2 COTE 1 13 FP2B33 A 50 1 9.3 as 1 15 FP2B-34 B 15 1 3.6 3.6 1 17 FP213•36 C 20 1 52 6.2 MLO. MAIN C8 FLUSH SURFACE SO MO FEED-THRU TO PANE. F7B 1 19 EOM 28.44 FP2644 A B 15 20 1 1 20 4.2 2.0 4.2 1 21- 1 23 FF2042 C 40 1 6.6 , ( 6.6 1 25 ECM 26-15 A 15 1 2.0 2.0 1 27 FP2B-15 B 20 1 4.2 4.2 29 SPAR C 20 1 31 SPARE A 20 1 33 SPACE B - 1 35 SPARE C 30 1 37 SPARE A 20 3 LOAD5LM1 MARY !111I•I.• in .III.I:I 39 _ B - - 41 - C - FEC KVA : 66.9 HEAT KVA : 155.2 MOTOR KVA : 0.4 LGHETGKVA : 3.4 KITCHEN KVA : 21.4 OTHER KVA : 24.2 PIPSEA KVA : 1055 AMPS : 3809 RASES KVA : 78.4 AMPS: 263.2 RSECKVA : 87.6 iA AMPS: 316.0 1 2 FP2836 A 40 1 6.2 6.2 1 1 4 6 LIGHTING /ESTAR LIGHTS B 20 1 6.6....................__.._. 1.0 .._ ___ 1.0 13.6 FF2B-08 C 40 1 ._.. 1 8 FP2B-07 A 20 1 4.2 : 4.2 1 ._.l 10 12 ELXI2B-07 FF2B-05 B C 20 20 1 1 ..._. 2.0 I _.. 5.2 ......... 2.0 6.2 1 14 FP2B31 A 50 1 9.3 ; ! 9.3 1 16 FP2B-45 8 20 1 42 4 a. 42 i 18 EEN 2B-06 C 20 1 32 ! --1 3.2 1 20 FF28-06 A 15 1 52 1 6.2 2,3 22 24 26 6N142-2 B 30 3 5.0 i I 5.0 5.0; '-� 50 50 5.0 - C A - - - - - 28 SPACEONLY 8 - 1 ._....._._.. 30 32 SFACECN Y -'-"_. C - 1 j.__._._ ._.__....... 1 F 4.9 1.7 16.6 SLIME DPANE 08A &EBB A 100 3 11.E CON!'ECrED LOAD 34 XFMR B - . 8.4 02 1 7.0 1.0 16.6 KVA : 271.5 AMPS : 326.6 36 - C - - 12.2 4.1 0.9 17.2 38 SLBFEE7 PANEL PSC & F8 A 100 3 11.6 1.5 7.3 20.5 COMM LOAD 40 XFMR B - - 12.4 Q2 7.0 19.7 KVA : 237.5 AMPS : 285.6 42 - C - - 10.3 1 3.9 6.2 20.3 NOTES/RBAARKS : 1. EXIST NG LOAD. 2 NBN LOAD. 3. PROVI OE CIRCUIT BREAKER I NDCATE] DEMAND! DIVERSITY FACTORS LOAD DESCF9:110V MAW R H M LM L K 0 RECEPTACLES HEATING MOTORS LIGHTING -T010KVA 100% = 10.0 10KVA 50% = 28.5 100% = 155.2 100% = 0.4 125% = 125% = 4.2 70% = 16.0 100% = 24.2 REMAINING OVER LARGST MOTOR FORO-ie'i OTHER (E) PANEL 'P8A' (SECTION 1) Ei4OJECT NAME CELLNETIX PROCT# 19256 LOCATION TLLAWA FED FROM PANEL F7 VA XFMR 1,,s3TE CKT NO. CJRCLIT NAME BAMPIP CB SIZE LOAD (KVA) R H M L K 0 TOTAL PAM .DESCRIPTION 1 1 REC- N A 20 11 1.1 1.1 RANG AMPS : • . X X 200 200 208 120 3 4 200A 1 3 RBC-N B 2D 1 1.3 1.3 FT3373R AMFS: 1 5 REC-N C 20 1 1.3 1.3 L-LVCLT8: 1 i 1 7 9 11 REC-C A 2D 1 0.8 ....................... 0.6 0.6 0.6 L -NVC TS PHASE W. RFC-C _PBC-_C B 20 1 0.6 ....... C 20 1 0.6 1 13 IBC-C A 20 1 0.6 0.6 1 15 Rt C- N B 20 1 0.9 0.9 1.3 ML.O. MAIN CS 1 17 RE3C-N C 20 1 1.3 1 19 REC- C A 20 1 0.6 0.6 ._...2.....21 2 23 REF- COFFEE MC- GF COFFEE 6 C 20 20 1 1 0.2 0.8 0.8 02 FLUSH SURFACE ISOCiND FEECTFi31X 25 SPARE A 2D 1 2 2..... 2 27 29 FUIdITU€ FEW- SIFFORT SERVICES B 20 1 0.7 .__.._....--._. ............. 0.7 0.4 -- _ SW RAN F®- SUiiXif SHiV1�.5 �---' C 20 1 0.4........ 2 31 PRNrBR- SUPPORT SE3RVOE A 20 1 0.8 0.8 2 2 33 36 PRIMER -SLPFORrSERVICE B 20 1 _..._. 0.8 0.8 0.7 FUERNITUREFFED-SLPPJRTSO?JCES C 20 1 0.7 LOADSUMMA , .. 2 39 41 SW.FIfB'L FEED-SUPDRr SEMMES B 2D 1 0.7 a.7 SPARE C 20 1 I3 KVA 32.6 FEAT KVA MOTOR KVA : 0.2 LGHTINGKVA : KITCHENKVA : 16.3 CRIER KVA : 3.7 P-ASEA KVA 18.6 AMPS : 154.8 RASED KVA ; 16.6 AWE : 138.7 R{ASECKVA : 17.2 AMPS: 143.7 2 2 2 4 REF- BREAK RM A 20 1 0.8 0.8 .._._._._.. 0.8 0.8 TEEN- BREAK RM __.._-10 2 6 SEC- BREAK RM C 20 1 0.5 0.9 1.4 8 SPARE A 20 1 2 __2. 2 10 -_ ❑N- BREAK RM B C 20 20 1 1 1.2 1.2 12 .........AK.. _... [15FDSBR-BAEAKtall'-------._._.--..._.__ -.--_1.1._..._._..._,- 1.1 2 14 NEC- N® CONFERENCE RM A 20 ! 1 0.9 0.3 1.2 1 16 IBC- N REC- N B 20 11 1.3 1.3 1 18 C 20 1 1.3 1.3 1 20 PBC- N A 20 1 1.3 1.3 1 22 F - N B 2D 1 0.4 0.4 1 24 FEC-N C C 20 1 0.5 0.5 2 26 14E-CONFE3RE4CE A 20 1 0.9 0.3 1.2 1 1 28 30 E F - f3EC ROOM R£C- 0 B 20 20 Y1 1 0.2 '-� 0.2 ,., 0.6 0.6 1 32 PLO- C A 20 1 0.6 0.6 OCN'ECTE D LOAD 1 34 PBC- C B 20 11 0.6 0.6 KVA : 62.5 AMPS : 145.6 1 36 fEC- C C 20 1 0.6 0.6 2 38 WRa11LD-FISH PREP A 20 1 0.4 0.4 CJEMF'DLOAD 40 SPARE B 20 1 KVA : 36.4 AMPS • 101.1 42 SPARE C 20 1 NOTEBRE MARKS : 1. EXISTING LOAD. 2 NEW LOAD. 3. DEMAND/ rxVEEEITY FACTORS LOAD CESCRIPTION DEMAND R RECEPTACLES H HEATING M MOTORS LM L Ha/TING K KITCHEN 0 OLHEi - TO ItMANING OVER LA RUES' MOTOR 10KVA 100% = 10.0 10KVA 50% = 11.3 100% = 100% _ 125% = 0.3 125% _ 70% = 11.2 100% = 3.7 (E) PANEL 'POD' (SECTION 3) PROECT NAME caLNETIx PROJECT A. 19256 LOCATION TUKVVILLAWA FEDFROM NOTECKT Na ORCUTNAME CB SIZE LOADfKVA) PANG DESCRIPTION 8 AMP! P R H M L K 0 TOTAL 1 SPARE A 20 1 PANEL AMPS FEEDER AMPS: L- LVOLTS: L - N VOLTS PHASE VVRE ML.O. MAN CB FLUS SURF •= SOGN• REED- : : : : X - X 225 200 208 120 3 4 2 3 REC-HALLWAY B 20 1 0.4 0.4 5 7-SPARE 9 SPARE C 20 1 SPARE A 20 B 20 1 1 __..- ,_ ...._.~ 1' 11 SNARE C 20 1 13 16 SPARE SPARE A 20 B 20 1 1 1 17 SPARE C 20 1 ? 19 21 SPARE SPARE -...- A 20 1 j B 20 1 23 SPARE C 20 1 I _..-__.... 25 27 29 SPARE 20 B 20 C 20 .._ 1 .. __... . ........._.._ ..._._.._._:_._..._.....r .._....L_ , _.-_.. SPARE -_..._ ---A SPARE .._. 31 33 35 S SPARE A 20 1 SPARE ---- ---- B 20 1 ------ ---- SPARE C 20 1 - _ __. ............._....-................. 37 SPARE A 20 1 i LORE/SUMMARY II,.1.•1 .1..1.111. I 39 SPARE B 20 1 41 C 20 1 REC KVA : 09 I -EAT KVA : MOTORKVA : 0.5 LGF(ElNG KVA : KITCHEN KVA : OTHERKVA : FH&SEA KVA : 0.5 ANDS : 4.5 PHASES KVA : 0.9 AMPS : 7.2 RAASECKVA : AMPS : 2 2 4 MC- ROOF GEO A 20 1 0.6 I 0.5 SPARE E El 20 1 ...__ i..._.__._..1 .._._...._...... 8 SPARE C 20 1 8 SPARE A 20 1 1 10 TFAN25 B 20 1 05 0.5 12 SPARE ... _.... . _. __...__ . _..__... C20 1 14 SPARE A 20 1 - 16 18 SPARE 0 20 1 SPARE _ C 20 1 20 SPARE A 20 1 22 SPARE B 20 1 24 SPARE C 20 1 26 SPARE ..... A 20 1 28 SPARE B 20 1 30 34 SPATE SFAREE C 20 1 A 20 1 CP•ECKLOAD ON 34 SPARE B ZO 1 KVA : 1.4 V AMPS : 39 36 38 SPARE _.. ..----'-_..---------..___._--- SPARE C 20 1 A A 20 1 OB44NDLCAD 40 sPARE B 20 1 KVA : 1.5 AMPS : 42 42 SPARE C 20 1 NCTEESIREMARKS : DEMANDI DVERSTY FACTORS 1. DOSTNG LOVtD. LOAD DESCRPTC*l CEIMND 2. NEW LOAD. 3. PROVICEORCUT BREAKER INCICATED R RI- ACLE3- TO 10K3/A 100% = 0.9 IeAAING OVER 10KVA 50% = H HEATN3 100% _ M MOTORS 100% = LM LARGEST MOTOR 125% = 0.6 L LGHfNG 125% - K KITCHEN 1C0% _ 0 OTHER 100% (E) PANEL 'P8' (SECTION 2) PROJECT mane CELLNETIX PROJECT 19256 LOCATOR TUIW.!LLA WA FED FROM PSC NOTE CIO'CIRCUIT Na NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION B AMP P R H M L K 0 TOTAL 1 SURGE FROTECT!r_.N rift - A 30 3 PANG AMPS: FE3D9RAMAS L-L VOLTS: L- N VOLTS PRASE CORE: ML.Q-5C 1a1r4 C8 FLUSH SURFACE ;so ay_ FATE RU : : : _ 200 200 208 120 3 4 3 B - - 5 - C - - _ 2 2 7 9 11 SPARE A 20 1 . f�C-OFFICES FAST B 20_.... 1 1.4 I _. _.. 1 I _. _... 1.4 REC- OFFICES EAST C 2 1 1.4... _._,_ _ 1.-0_. 2 13 REC• OFFICES EAST A 2 1 1.4 I 1.4 ..,.2 15 .17 SPARE AEC -RPM B 20 C 20 1 1 0.2 ' p.2 2 19 PBC- OFECES EAST A 20 1 D.7 D.7 1 2 21 23 REC-C B 20 1 0.6 0.6 RE3C- RECEPTION! C 20 1 0.6 i - ' ---_- Os- 2 25 PRNTER- RECEPTION A 20 1 i as D.8 2 2 2 27 29 REC• OFHCYS EAST MN -COFFEE --- B 20 1 1.4 I 1.4 C 20 1 ---._ I ._.'. _.15 b.._..- 1.5 2 31 COFFEE -COFFEE A 20 1 1.5 1.5 2 2 33 35 COPIER. COFFEE B 20 1 Q8 0.8 t7Nf-00FFff C 20 1 ..... ._... _.. __. .._.12_.. ,2 '2 37 FURJrRAEFEED- BROOM A 20 1 0.5 0.5 LOAD SUM MARY . 1111.411 :II: u.,:I 2 39 FUR4[fl. FEED -IT ROOM B 2 1 DA D.4 2 41 SW FURNITURE FEED - B ROOM C 20 1 1.1 1.1 REC KVA : 20.8 PEAT WA : MDTOR INA : US-1T C KVA : KITCHEN KVA : 5.4 OTHER kVA : 3.7 FHASEA KVA : 96 AMPS: 80.0 RASE B KVA : 94 AMPS : 78.0 RASE CKVA : 10.7 ALPS : 89.5 2 2 2 4... FURN ITURE FEED- IT ROOM A 20 "B 1 0.4 0.4 FIRNRUREr®-BROOM 20 1 0.4-.._.-_- _._........ .._..._...... _.....--.... 0.4 2 6 SW, FURS. F®- R ROOM C 20 1 0.7 0.7 2 8 FEC- SMALL ODNFEREPCE EAST A 20 1 0.9 0.3 1.2 2 10 CORER -OPENCFFICEEiAST B 2D 1 0.8 0.8 - 2 12 DISPOSER - COFFEE C 20 1 1.2 1.2 1 14 FEC-N A 20 1 1.1 1.1 1 1 16 18 REC-C REC-C B 20 1 0.6 0.6 C 20 1 .1 0.6 __.---- 0.6 2 20 as 0.8 OJD-OFENOFFIE l-..--•--T--------A--20 1 22 REC-C B 20 1 DES 0.6 1 24 EEC-N ---'-'--'-' ......... ... b 20 1 1.1...--- --__ ... 11 26 SPARE A 23 1 .._..- ---_-- ----- --_.-___- 1 28 REC-C B 20 1 0.6 ....0.6 0.6 1 30 ,,,.,.. MC-C C201 ------- ---- 0.6 32 SPARE A 20 1 COM 1WLOAD 1 34 REC-C B 20 1 0.6 0.6 KVA: 29.7 AMPS: 82.4 1 1 36 38 SEC -C FCC-N C 20 1 D.6 D.6 A 20 1 1.1 1.1 DESANCLOAD 1 40 REC-N 8 20 1 1.1 1.1 KVA: 23.3 AME : 64.7 42 SPARE C 20 1 NOTESIFMA APB : DBlIAND ! DVBRSITY FACTORS 1. EXISTING LOAD LOAD C6CRPTCN DEMAND 2 NEW LOA ❑ a R RECEPTACLES - TO 10KVA 100% - 10.0 RB.ANNG OVER 10KVA 50% = 5.3 H MA WC 100% = M MOTORS 100% = LM LARGEST ACTOR 125% = L UGITNG 125% _ K 10TM EN 80% = 4.3 0 OTHER 100% = 3.7 (E) PANEL 'PSC' (SECTION 2) CELLNETIX PROJECT #: 19256 PROJECT NAME LOCATION TUNVILLAWA F®FROM FSB NDIE CKr NC CIRCUIT NAME 8 CBSIZE LOAD(KVA) PANEL DESCRIPTION AMP! P R` H NI L K I 0 TOTAL 2 1 CaTO Cate PAWL A 20 1 i 1.4 1.4 ' FAIVaALIFS FEtCBi AIWS: L-LVOLTS L- NVOLTS: PEASE WIRE: MLO. MAIN CB� R_ - SURFACE SO a FEED- - : : : Li X X 226 200 208 120 3 4 2 3 N CELG PANEL -CENTRE GE-CY TO B 20 1 i- 1.4 1.4 2 5 CEILING PANEL -C N1TIFU3E-CYTO C 20 1 14 1.4 2 _...2 .. 7 9 CaNGPANEL-034TRFUGE-GYP] A 20 1 I I.1.4 �.. ........_ 1 1.4 0.4 CELING PANEL -CYTO B 20 1 0.4 2 11 CEILING PANEL -CYTO C 20 1 0.4 0.4 2..... 13 15 SPARE ---if- A 20 26 1 'f 0.4 1 ____.. ..... _.. ._.__.. Q4 CatGPANEl-MOLHALARPOST 2 17 CELNGPANEL-MC ECUARPOST C 20 1 DA - 0.4 2 -.2_... 19 21 CPANEL_MOLECU_AR POST A WI; 20 1 1 0.4 0.4.... -... I f. 0.4 0.4 CaINGPANEL-MCLECI.LARPOST 2 23 CANGPANEL - MW- MOLECUAR POST C 20 1 1 221 2.2 2 2__ 2 25 27 29 tiEC- Oi'lING- MOLECULAR POST A B 0 20 20 1 1 I 1 1.8 •8 0,2 1.8 18 0.2 MC- POST WR MOLD-ISO-MOL67AARFOST 20 1 2 _..2... 31 33 WReCLD-FISH A 20 1 0.7 I ' 0.7 WRDnD- FSH 8 20 1 0.7. 36SPARE C20 1 + 37 SPARE A 20 1 -f LOAD SUMMARY 111I•I.., :,1:,111"• 4 _._.._.- 39 41 SPARE B 20 1 ---..._.+....._.1 1 SPACE - --- C - 1 "---- RICKVA: 10.3 FEATKVA: MOTORKVA : 0.5 LGHfNGKVA : KRGENKVA : 22 OTFBRKVA : 123 A-IASEA KVA : 8.7 AMPS: 721 FRASEBKVA; 8.7 AMPS: 722 PHASECKVA : 7.9 AMPS: 66.0 2 2 •- 2 2 4 6 CaPGPANEL-h10L. POST A B C 20 20 20 1 1 0.4 0.4 I '.._....._.. 0.4 0.4 CaNGPAN3.-MOLEJIARFOST--- CELPCPAr.a- MOLBXLARR)ST .......... 1 0.4 0.4 8 SPARE A 20 1 10 SPARE WMAOLD-FLOW _ _ ._.__ .. ...... B C20 20 1 1 --- 0.9 2 12 0.9 ------- 2 14 CSNG PANEL -FLOW A 20 1 0.4 0.4 2 16 CEILING PANEL- FLOW B C 20 1 0.4 0.4 1.4 2 18 CaNGPANEL-BSC-FLOW 20 1 1.4 2 20 CaNGPANEL -MOLIELLARPRE A 20 1 0.4 0.4 2 --2-124 2 22 WRBIQ.D- MOLau.AR PRE B 20 1 0.9 0.9 26 CaNGPANEL-FLOW C tGPANEL-FLOW C A 20 1 0.4 0.4 0.4 20 1 0.4 2 28 CELNCPANEL-COPIER-FLCNV B 20 1 0.8 0.8 2 30 WRINOLD-MOLOUARFRE C 20 1 0.4 0.4 2 32 WRB'AOLD- HOOD- MOLECULARPRE A 20 1 0.6 Q6 OCNNBLiwLOAD 34 SPARE B 20 1 KVA : 26.2 AMPS : 70.1 36 SPARE C C 20 1 2 38 CatGPANEL-CYTO A 20 1 0.4 0.4 L'B4ANDLCAD 2 40 CEILING PANEL-CYTO B 20 1 0.4 Q4 KVA : 26.2 ANPS : 70.0 42 SPACE C - 1 NOTESJREMARI6: 1. IXIS11N0 LOW. 2. NE3NLCIAD: 3. PRI7VIDEWRCUT BREAKER INDCJATEC E7EMANDT DVBRSTY FACTORS LOAD DESC78PTON 01344N3 R H M LM L K C RECEPTACLES -TO10KVA 103% = 10.0 RBA INNG OVER 10K1A 50% = 0.1 100% _ 100% = LARGEST MOTOR 125% = 0.6 125% - 100% = 22 100% = 123 HEATNG MOTORS LIGHTING KRCI•B4 OTHER (E) PANEL 'PBC' (SECTION 1) CELLNETIX PROJECT# 19258 PROJECT NAM'_ LOCATION TUKWILLA WA FED FROM PANE. P7 VIAXFMR NOTE CKT PC CIRCUIT NAME 8 CBSZE LOAD(KVA) PANG cBBcNFT ON AMP! P R H M L K 0 TOTAL 1 1 1 REC-C A B 20 20 1 1 0.6 0.6 0.6 PANG AMPS FEEDER AMPS L-LVCJLTS L- NVCLTS FNASE: V11RE: ML.Q WINOS FLUSH SURFACE : : : : X _ 200 200 208 120 3 4 ROOM 3 RO-C 0.6 1 5 REG-C C 20 1 0.6 0.6 1 ...�� 7 8 Yt" iREC -N R L-C-N A -6-1-5 C_... 20 1 1 1.1 _-.... 1.1 ._. N....... ,..... - I I f _... - 1.1 1.1 SPACE i 1 13REC-C A 20 1 0.6 t 0.6 1 2 15 .17 AEC -C Ra-'OFFICES BAST B C 20 20 1 1 0.6 1.4-. .... ------ i .F... ..............t_.___. 0.6 __ 1.4 19 SPARE A 20 1 21 23 SPARE B 20 1 I I (--------- SPARE C 20 1 ISO G'D FEEDTFRUX 25 SPARE A 20 1 1 1 i . .27 29 SPARE B 0 20 1 .... I 1 SPARE_........- 20 2D 1 _ 31 SPARE A 20 1 2,3_ 33 35 -37 SPARE SPARE _.----'- _- 8 C A 20 1 ... _,t..... 1 1 -6.3....-5.3 _._.._ . 20 100 1 9 ..... _ ...... 113107ALFP8 ._ -......__ __.. LOA08UMMARY 11 I.I.a11 :I:IVII .•.I 39 - B - - i I i 5.3 ...__..._f..._......_i._..__-:...63... , 5.3 5.3 41 - C - - REC KVA 34.3 FEAT KJA MOTOR MIA 0.2 LIGHTING KVA KITCHENKVA 5.4 0THERKVA : 20.5 RASE KVA : 20.5 AMPS : 170.4 PHASE B KVA : 19.7 AMES : 163.9 PIiASECKVA : 20.3 MAPS : 169.4 1 ...._ _......4.... 2 R -N A 20 1 1.1 1 I I 1.1 -0.6 _ C___. B 20 1 0.6... 1 6 RJC-C C 20 1 0.6 0.6 1 8 NEC- N A 20 1 1.1 1.1 1 1D REG-C B 2D 1 0.6 0.6 1 12 MC-C C 20 1 0.6 0.6 1 14 REC-N A 20 1 1.1 1.1 1 2 -- 18 18 RO- N B 2D 1 1.1 1.1 COPIER -OPEN CJFRCE C A 20 �-__ 0.8 0.8 20 SPARE_ " 22 SPARE SPARE SPARE B B 20 210 1 1 1 - -.__---_ 24 26 28 SPARE B 20 1 30 SPARE C 20 1 32 SPARE A 20 1 OONI'ETED LOAD 34 SPARE B 20 1 KVA : 805 AMES : 167.8 38 SPARE C 2D 1 38 SPARE A 20 1 DEAANC LOAD 2 40 EEC-J.ANITCRS/LHWFP-2-1 B 2D 1 0.2 0.2 0.4 KVA : 48.4 AMPS : 134.2 2 42 REC. ROOF GFO C 20 1 0.2 D.2 NOTES:RBA ARKS: 1. EXISTING LOAD 2 NEW LOAD 3 PROVIDE CI RCUIT BREAKER I ND CAT ED. DEMAND/ DVBi9ITY FACTORS LOAD CFCRIPTION ceMI'D R RECEPTACLES H FEATNG M MOTORS LV L LIG4TNG K KTCJ-IEN 0 OTHER - TO REN..INNG OVER LARGEST MOTOR 10KVA 100% = 10.0 10KVA 50% = 12.2 100% = 100% = 125% = 03 125% = 100% = 5.4 100% r 20.5 (E) PANEL 'PSB' (SECTION 1) PROJECT NAME CELL NETS PROJECT # 19256 LOCATION TUKNILLAWA FED FROM PANE. P5 VIA XFMR NOTECKT NO CIRCUIT NAME CB 312E LOAD(KVA) PANG DESCRIPTION B AMP P R H NI L K 0 TOTAL 1 1 REr-tB+RM A 20 1 0.2 0.2 PANEL MAPS FEDERANIS: L- LVOLTS: L- NVOLTS PHASE: IMiE ML.O.� WONCB R115 SLRFA• ISO CND FEEDTFRU : : : X X X 225 200 208 120 3 4 200A 2 3 WRINCLD- MICJa7TGK1Y B 20 1 0.7 0.7 2 5 WRBAOLD-MICRDTOMY Cr20 1 0.7 0.7 A 20 1 0.8 Q8 2 2 7 .....9 CXJPER-MICROTOMY CaNG PANEL -EMBEDDING B 20 1 0.4 ...0.4 2 11 EOUFMENT - EKBHUIVG C 20 1 1.1 1.1 2 2 13 15 MOMENT-ENBEDIVG A 20 B 20 1 1 „_, 0.4 I 1 1.1 1.1 0.4 CaNOPANEL-AEf.R01ow -__ 2 17 WRefOLD-TISSUE-CYTO C 20 1 ! ¢ 1.4 1.4 2 -.2 .. 19 21 WRBIAOLD•TLSSIE•CYTO ----� VURBAOLD- TSSIE-CYTO A 20. B 20 1 7 1.2 1.2 1.2 1.2 2 23 WREMOLD-TISSUE-CYTO C 20 1 1.2 1.2 2 25 C tGPANEL- DST1R3UTEN A 20 1 0.4 0.4 2 27 CaN3PANE- -BSC-CYTO B 20 1 :__....._ - 2 29 CELFORMEL-STANNI3 C 20 1 0.4 .... _..__.. 0.4 2 31 WRE3,IDLD-CYTO A 20'1 1.1 1.1 2 33 CaNGPANJEL-CSTRBUTEN B 20 1 0.4 0.4 2 36 CELNGPANEL - CYTO C 20 1 0.4 0.4 2 37 CaINGPANEL-DISTRBUTCN A 20 1 0.4 0.4 LOAD SUMMARY III 1.,.., .,1 „11„: 1 2 39 41 (INGPANEL-BSC-CY TO B 20 1 0.4 0.4 C 20 1 .................'-'-- r--'--.._.{__....,_ REGINA : 20.9 HEATKVA : MOTORKVA : 0.6 UGHTNGKVA : KRCHENKVA' 22 OTH9t KVA: 20.E PIV.SEA KVA : 15.6 AMPS : 129.6 PHASE BKVA : 13.6 AMPS : 113.7 HAASECKVA : 14.7 AMPS : 1225 SPARE....._... 1 2 SFD -- ----- A 30 B 3 ...._..---.._.__._._....._.._..F--...-..- ----- - C - - 6 2 8 CaNGPANEL- MOROTOMY A 20 1 0.4 0.4 2 10 CELNGPANEL-MCROTOW B 20 1 0.4 0.4 C 20 1 0.4 0.4 2 12 CBNG PAPEiL- MOiDTOMY 2 14 CEILIKOPANEL•CRYTOMY A 20 1 0.4 0.4 2 2 16 18 EREC- CY TO B 20 1 0.4 0.4 C 20 1 0.4 0.4 CEILINGPANEL -CYTO 2 20 CaNGPANE..-MCRDTOMY A 20 1 0.4 0.4 2 22 CatG PANEL- MLTCTOMY CELN3RANEL-STA.IVI'G 8 20 1 OA 0.4 2 24 C 20 1 0.4 0.4 A 20 1 0.4 -------- 0.4 2 25 CBLI4J3PANEL- CSTRBL!TCN 24 28 WREMOLD- 6-20R- CY TO 8 20 2 0.2 0.2 24 30 CaNGPANEL CYTO _ _ ___.. ........ C - - 0.2 0.2 A 20 1 0A 0.4 CONNECTED LOAD 2 32 2 34 CaNGPANEL CYTO B 20 1 0.4 0.4 KVA : 43.9 AMPS : 121.9 2 36 CatGPANEL CYTO C 20 1 0.4 0.4 A 20 1 DEMANDLOAD 38 SPARE 40 SPARE B 20 1 KVA : 38.6 AMPS : 107.1 42 SPARE C 20 1 NOTES/REMARKS : DEMAND I oV 679TY FACTORS 1 ECSTNJGLDAD. LOAD DESCRIPTION C9400 2. NEW LOAD. 3. PROVIDE CIRCUIT BREAKERINOCATED 4. TWO -POLE HANDLE TIE R RBPTACLES - TO 10KVA 100% = 10.0 RBAM.INE+G OVER 10KVA 50% = 5.4 H HEATING 100% _ M MOTORS 100% = LM LARGEST ACTOR 125% = 0.6 L LGMNC 125% _ K ICTO-B4 100% = 22 0 OTHER 100% = 20.3 (E) PANEL 'P7B' (SECTION 2) PROJECT NAME CELLNETX PR7.1CT9 19256 LOCATION TUKIMLLAWA FED FROM FANEL F7 NOTE CID ND CIRCUIT NAME CB SIZE LOAD(KVA) PANEL DESCHPTION B AMP! P R H M L K 0 TOTAL 1 1 FMB-09 A 30 1 66 6.6 PANEL AMPS : : : : : X 400 400 480 277 3 4 1 3 FF26-10 B 15 1 29 29 FEEDER AMPS L- L VOLTS L • N VOLTS PHASE: IMRE ML.O.T MAIN CB FLUSH SURFACE SOGND_ FEW-TFRU 1 5 FP2B-11 C 15 1 39 3.9 1 .._. 1 7 9 FP2B-12 A 25 1 5.6 I__.___.____._. _.. _..1. 6.6 4.2_.. _ FP2B-38 B 20 1 4.2 1 11 FP2037 C 15 1 3.2 1 1 3.2 1 1 1 13 FF2B-13 A 15 1 4.2 29 I I .---. i -.,2.., 2.9 FP2B-39 B C 15 1 FP2B-41------------- 20 1 4.2 14.2 1 19 FP28.40 A 20 3 29 I i 29 i - - 29 I 29 _29 29 21 23 B C : _.--.._ - 25 SPACE A - 1 27 SPACE B • 1 29 SPACE C - 1 31 SPACE A - 1 33 SPACE B - 1 SPA.CE C - 1 SPACE A - 1 * LOAD SUMMARY ,III1f1.• I.. 1:1 IN:I .... 38 41 SPACE B 1 , I .........._i.._.__..._.�...___•_._._ - . _ __ + ..._.. C - 1 .... RE3; KVA : FEAT KVA : 46.1 MOTORKVA : LIGHTINGKVA : 2.4 KITCNEi4 KVA : OTFiBRKVA : PH&SEA KVA : 19.3 AMPS: 69.7 PHASED KVA : 15.1 AMPS: 64.7 FFASECKVA : 14.1 Al:PS50.8 2 4 SPARE SPARE A B 20 20 1 1 .....____.__..._.____w-..._.__ i I I ___...._-,,.__....._. 6 SPARE C 20 1 1 I 8 SPARE A 20 1 10 SPARE B .0 20 20 1 1 1 12 SPARE -..._ 14 SPAR A 20 1 2 16 LTS- SEOFTiCES B C A 20 27 -_. 1 1 1 - _"'_---- -_--I 2.4 ----'-___._ _------ 2.4 18 SPARE 20 SPACE -- ...__ - 22 SPACE B C A - - 1 1 1 _._.�-t I I- - 24 26 ........ SPACE SE14CE -'- - -------- 28 SPACE B - 1 30 SPACE C - 1 1 32 SPACE A - 1 CONNECTED LOAD 34 SPACE B - 1 KVA ; 48.5 AMPS: 58.4 36 SPACE C A - 1 38 SPACE ... __-_....___.... - 1 DEMAND LOAD 40 SPACE B - 1 KVA : 49.1 AMPS : 59.1 42 SPACE C - 1 NDTESiREM ARKS : 1_ EXISTING LOAD. 2. NEW LOAD. 3. ROUTETHROWH LIGHTING CONTROL PANG. DBAAND / DVERSITY FACTORS LOAD CESCRPTON DEMAND R RECEPTACLES -T010KVA 100% = REMAINING W6R 10KVA 50% = H FEATINEG 100% • 46.1 M MOTORS 100% = LM LARGEST MOTOR 125% = L LIGHTING 125% = 3.0 K KIR:HEN 100% = 0 OTHER 100% = ELi 9-0949 2 Nickerson Street Suite Nettle, WA 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP INC ..-� 15323 NE 90th Street Redmond, WA 98052 Phone: 425-823-8600 Fax: 425-823-8655 CASE ENGINEERING Consulting Electrical Engineers 19515 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S Tukwila, WA CONSTRUCTION DEVELOPMENT i N1rh: '. -mac I ( } Ity of TukwiT1 JUILDING ON!SION L J SPACE FOR OFFICIAL CITY USE ONLY PANEL SCHEDULES DATE 11/11/2019 CHECKED BY TN PROJECT NUMBER 19256 E10.2 E E E D C B A RECEIVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER 0 PROJECT NAME cELLNErIx (N) PANEL 'SB1' (N) PANEL'SBDL' LCCA Dom NOT CKT ND. 3 5 7 TUK%MLLA WA FED FROM SSD. PROJECT tr: 18256 OUT NAME Ym¢M.J1U - 9YBEG WRECID- N CR1TO%W FRZR - MICPDTOMY FRLR-MICibTOMY - 9 11 13 15 17 19 21 CEILING PANEL - &CROTON CEILING PANE_ - MCROTOMIY CEILING PANEL - MIZROTOMY CEILING PANEL - 'CROTOMY OILING PANE.- MCR07C51Y CB SIZE LOAD(KYA) 8(AMO R H M L K A B 20 20 B 20 C A B 1 1 1 0.7 0.9 1 0.4 211 2011 21?1 0.4 0.4 0.4 1.6 1.6 0 TOTAL ®LING RMS. - SPMALS Rc'F- CP- SR37ALS VNRFAIOLD-REF-SPECjgj;;g....._..___....__...._..._. VMREMOLD-SPECIALS SPARE FSD-LEVEL 1 HAZMAT REC- H4ZM1ATSTORAGE CF•18 FCLN-1 6 2 • net - MUCDILSAT 8 10 20 22 24 26 REF- MCRCITOMY DOLING PANEL - IC- MCROTC34Y (DING PANEL - I-C- MCR)rG Y CEeLIIVG A4NFL - HC- MCRCTCMY DIEING PANEL- IC- MCtOTCMY OILING PANE - I-C. MCROTOMY CEILING' FANS. - MCROTO MY GEEING PANEL STAINING --- C 20 11 0.4 A B C A B C A B C A B 20'1 20 1 20 1 20!1 20 1 1 20 El 40 12 c 0.4 1.1 1.1 0.7 0.4 0.4 0.7 0.9 1.6 1.6 0.4 0.4 0.9 0.4 0.4 0.4 1.1 1.1 0.7 04 0.4 0.6 0.1 3.3 3.3 1.1 0.1 1.4 0.7 20 Nan Ci LI OM= 0 0 - -----I......_.... IMItti 20 2111 C IL*1GPANELSTANNG DIEING PANEL- STAN- STAINING CEILING PANEL - STAN- STAINING CELING PANEL- DSTREUTION 38 40 42 T PA . L71C SPARE....._.. SPARE 20 1 20 1 20 0.4 0.4 ing _1111 SPARE SPARE NOTE S(REMARKS . 1. 2 3. 20 1 20 1 20 1.4 1.2 0.1 0.6 3.3 33 1.1 1.1 1.4 1.4 1.2 1.2 1.2 0.4 1.1 1.1 0.4 0.4 1.1 11 0.4 0.4 PANEL OESCRPTION PANEL AMPS : 100 FEELEiAMPS : 100 L- LVCLTS: 208 L -N VOLTS : 120 PHASE: 3 WIRE : 4 M.L.O. WMCB FLUSH SURFACE SO FEED PRU LOAD SUMMARY (TOTAL. ALL fttT'WS REC KVA : 7.9 HEAT KVA : MDTORKVA : 86 LIGHTING KVA : IOTCH34 KVA : 7.5 OTHER KVA : 10.9 PHASEA KVA : 10.3 AMPS : 85.7 PHASES KVA : 11.1 AMPS : 92.6 PHASEC KVA : 11.6 AMPS : 96.3 20 20 1 DEMAND! DVIRSITY FACTORS LOAD DESCRIPTOR CONNECTED LOAD KVA : 329 AMPS : 91.4 DEMANDLOAD KVA : 31.9 AMPS : 88.6 RTACLES- TO 10KVA RSMAINN3 OVER 10KVA H HEATING M MOTORS LM LARL,STMOTCt L LGHTNG K 10TO$4 0 OTHER DEMAND 100% = 7.9 509E 100% • 100% = 0.1 125% = 8.1 125% 65% • 4.9 100% = 10 (N) PANEL 'SB5' PROJECT NAME CELLNET1x LOCATOR PROJECT*: 10256 TUOMLLA WA FED FROM 30KVA )(RR NOTE CKT PC. OFCUT NAME CB SIZE LOAD (KVA; A AMP R H M L 1 ROC- K 0 TOTAL PANEL DESCRIPTION Lf A 2D 1 0.2 0.2 PQa AMPS 3 REC-DF B 2D 1 0.4 0.4 : 100 FEE:Et AMPS: 100 . ...........- . a RED- DF REC- ICE_ C C 20 A 20 : 1 0.4 1 0.4 ........... .... ...._.._._ . ......... _. _ .__...._..... 0.4 0.4 L - L VOLTS : 208 L-NV(I_TS: 120 9 9 SPARE B 20 1 1 PHASE 1 11 SPARE C 20 ; 1 : 3 WIRE : 4 13 SPARE A B _....2__0 20 11 1......_1 I _ 15 SPARE ---- ..._ �� 17 SPARE 2.m • • 19 SPARE 21 23 SPARE SPARE A B 20 1 2D1 2J(1 M.L.O. MAX rill 100e 1 FLUSH SURFACEr1 ISO e 464 ■ FEED-SShRU 6 8 10 20 22 24 LO-04A11L.1' 16KVA UPS 302 1.6 11/1711111111 ERIC to airia111111111 111-1.11111111111111 SPARE B.0 6.0 1.5 L5 1.5 1.6 1.0 1.0 8.0 80 LOAD SUM MARY ITZ rAL.A LL Mt T 045 REC KVA : 93 HEAT KVA : MOTOR KVA : LIGHTING KVA : 4104114 KVA : 16.0 OTHER KVA : PHASE KVA : AMPS : RASE KVA : AMPS : PHA SEC KVA : AMPS : 11.5 96.2 10.9 90.5 29 23.8 ONNIMTED LOAD KVA : 25.3 AMPS : 70.1 NOTES(REMAPI(S 1. 2 a CBMAM!DVERSTYFACTORS I_ 1 DEMANDLCAD KVA : 25.3 AMPS : 70,1 LOAD DESCRIPTnN RRECEPTACLES- TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGST MOTOR L LGHRJG K KITCHEN o OTHER DEMAND 130% = 9.3 509E _ 100% _ 100% 125% 125% 100% - 'F.0 100% _ PROJECT NAME CELL NETIX LCCATIONL TUIOAIL LA WA NOTE CKT 1 3 6 CIRCUT NAME PAIR SB1 7 PANEL 682 11 13 PANEL $L-V 15. .......................... 17 19 21 25 27 SPACE PANEL SB6 (GROSSING) SPD 2 PANS_ SB3 4 8 10 12 14 16 18 RANEE S84 SPARE 20 SPARE 22 SPARE 26 26 SPARE SPARE 30 SPARE NOTES/REMARKS : FED FROM SBD VIA xFMT CB SIZE 8A A 100 3 100 3 LOAD (KVA) 3.4 H I M L K 1I 27 2.7 3.3 1.8 3.4 29 1.7 ! 5.4 _._....__..__L.__. _....__.........-----.. 1.4 0.1 i 1.8;54 2.2 2.7 0 TOTAL 4.2 10.3 3.0 11.1 3.7 11.6 20 0.2 0.2 27 1.8 1.4 1.8 1.6 1.3 0.1 1 64 0.3 I 10.0 8.7 7.6 0.5 0.2 9.0 9..3 8.3 8.3 8.3 _.88..3. .3 3.3 5.8 i ao 3.8 6.6 3.3 4.8 2.6 1.8 4.9 1.1 DEMAND I DIVERSITY FACTOIIS 14.7 12.1 12.0 8.5 'R0.122- 19256 PANEL DESCRIPTION PANEL AMPS : F®ER AMPS : L-L VOLTS : L-NVDLTS: RASE: AWE: M.L.O. M44NCB FLUSH SURFACE ISO GAD FEED THH1 r X R 400 400 208 120 3 4 400A LOAD SUM MARY REC KVA : 25.0 PEAT KVA : MOTOR KVA : 21.4 LGHTNG KVA : 0.4 KITCHEN WA : 26.6 OTHER KVA : 82.4 PHASEA KVA : AMPS : RASE B KVA : AMPS: PHASE CKVA : AWES 529 440.8 52.8 438.1 50.3 419.6 CONNECTED LOAD KVA : 155.8 AMPS 432.5 C MANDLOACP KVA AMPS : 392.9 LOAD DESORFDON R RBOEPrAC LES - TO 10KVA %P AINK3 OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER DEMAND 100% = 10.0 50% = 7.5 100% = 1009E = 11.6 125% = 12.2 125% = 0 6 65% = 17.3 100% = 82.4 PROJECT NAME CELL NETIX LOCATION 10. (N) PANEL'SB4' TUKWILLA WA CIRCUT NAM E FED FROIrt CB SIZE 0 A P R 1 WREMOL0• MOLECJLARFiiE A 20 1 0.7 3 VMRE MDLO- CIASYI H- MALECAAR PRE 6 20 1 Wf113.0L0-CYASYMFH-MOLECLARFRE C 20 1 CUING PAM3_-MOLEII.ARPRE A 20 1 0.4 CEILING PANE- --20LC- MOLECULAR PRE B 20 1 CEILING PANEL- DNA- MOLECULAR FIRE C 20 1 VWB+OLD-HI1413C-MOLECJLARRTE A 20 1 t CID-MOLECLARFRE REC • FRZR- MOLECULAR PRE REC- REF- MOLECLAR PRE NRBLOLD- RSH PREP WRELOLD- FISH WRBMJLD- NCAATOR- MD1.6JLLAR FOS WRBLOLD- INCUBATOR. MCLECLLAR FOS SPARE SPARE SPARE SPARE SPARE SPARE SPARE CEILING PANEL - GENETIC- MOLECUL. POST CELIAC PANEL • MOLECLLAR POST 0.9 LOAD (KVA) 1.1 1.8 A 20 C 20 1 C A B 20 20 20 1 0.4 0.9 C 20 1 D.4 CEILING PANEL - L1CFAC(US - MCLE POST A 20 1 CEUNG PANEL - THERMAL -M7LEC POST 8 20 1 OILING PANE - TMHMAL - ICLEC POST C 20 1 DOLING PANEL - MCLPLU.AR POST CEILNG PANEL - MOLECULAR POST B 20 1 0.4 SPARE SPARE SPARE SPARE 34 SPARE 36 SPARE 38 SPARE 42 NOTES/REMARKS : 33 3,3 DEMAND I OVERSITY FACTORS 0.5 0.5 2 1.2 0.5 a5 .6 1.6 1.1 1.8 1.2 1.2 1.2 0.4 3.3 3.3 141.6 PANEL DESCRIPTION RAW -AMPS : 100 FEECER MSS 100 ARE 4 MAN CS FLUSH SLEFA ISO GND FEEDIHRU FEAT KVA : MOTOR KVA : 6.5 KITCHEN WA : 2.9 PHASE A KVA : RASE B KVA : ALES : 8.5 70.7 122 11.1 92.2 CONNECTED LOAD DEW P4) LOW LOAD DESCRIPTION DEMAND REMAINING OVER 10KVA ▪ FEATING M MOTORS LM LARGEST MOTOR 0 OTHER 100% = 50% 10(7)6 at 100% = 125% 100% = 4.7 81 17 7 (N) PANEL 'SBDI LOCATION TUKAILLA WA NOTE CKT 3 CIFCUT NAME CB SIZE LOAD (KVA) A TOTAL 5 7 11 13 15 17 19 21 26 27 31 33 35 37 39 41 2 4 A 20 1 20 1 20 f 3,8 1.5 3.5 A 20 1 20 20 20 1.3 20 25 35 24 3.8 1.6 3.5 13 2.0 2.5 3.6 ITS- LEVEL 2 SE OFFILt5 SPARE - SPARE SPARE SPARE SPARE A SPARE SFARE SPARE S PARE SPARE SPARE A A 2011 20 11 20 20 1.6 24 1.6 2.4 A 20 20 A 20 20 203 3 7.8 03 52.9 10 12 14 10 20 16 18 20 26 A 3.5 2.9 20 8.0 8.0 50.3 2.0 2.0 11.5 10.9 SPARE 29 A 20 3 2.9 32 SPARE 34 aa 42 SPARE SPARE SFARE SPARE SPARE A 5.5 5.8 5.6 5.6 5.6 6.6 A aa PROJECT*. 19256 PAWL CESCF1P110N MI 0 PANINI CB FLUSH SUFFA GO FEEDIPRU FEAT KVA : LIGHTING WA : 24.9 01HER KVA 82.4 RASE 13 KVA : 20 1 a DBA AND/ DIVERSITY FACTORS LOW CESCRETCN 828 29118 79.6 287.3 66.0 238.1 CCNNVIED LOAD CEMAIC LOAD CEMA ND MANIC CA/ER 10KVA M MOTORS UA LARGEST MOTOR 125% 125% 10.0 12.1 27.4 20.9 LCP RELAY SCHEDULE LOCATPON: ELECTRICAL ROOM RELAY CIRCUT SWITCH LOCATION ONOFF TIME DAYS NOTES NOTER PROJECT NAME CEL LNETIX LCCATTON TURA] L LA WA FED ROM NOTE CM ORCUIT NAME CB SIZE LOAD (KVA) 11 13 17 19 21 23 25 27 29 31 .33 37 39 41 2 4 MUD PANEL - CY TO WARE A CEILING PANEL • PANTHER- CYTO 20 20 1.8 0.4 0.4 A 20 20 1.8 1.8 1.8 1.8 1.8 1.8 1.8 0.4 1.8 10 12 14 SPARE SPARE SPARE A 20 1.2 1.2 1.2 AREMOLD- FLOW MAREIVOLD- FLOW 20 A 20 min PANEL RoW CELLO PANEL - FLON 20 1 20 1 0.4 0.5 0.5 OA 20 1 20 1 18 18 22 24 26 28 32 34 36 38 42 SPARE REF - FR7R STORAGE REF - FRIZR STORAGE A A 13 20 1 20 1 0.9 1.9 1.9 0.9 1,9 1.9 20 1 REF- FRZR STORAGE A 20 1 20 1 20 1 19 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 SPARE sPARE SPARE SPARE A 20 1 3.3 3.3 3.3 A 20 1 20 1 DEMAND/ OVERSITY FACTORS MAIN CB FLUSH SLREACE 180 OW MOTOR KVA : 6.5 LIGHTING KVA • OTHER KVA : 12.2 AMPS : PHASES KVA : AMRS AMPS : 14.7 122.6 12.1 100.5 12 0 100.0 CONNECTED LOAD KVA 38.8 AMPS 107.6 LOAN) LOAD KVA 35.4 AMPS 98.2 LOAD rFsCRIPTICN R RECEPTACLES- TO 10KVA M MOTORS LM LARGEST mcrrOR L LIGHTING K KITCHEN DEMAND 100% 125% LCCATON TLIKWILLA WA FED FROM PANEL FBA 2 15 SW. FURN FEED- SCREENING B 20 1 0.7 0.7 2 23 REC- BREAK EN Of C 20 1 0.7 0.7 SURFACE X 3 31 SPARE 20 1 FEAT KVA : MOTOR KVA : 1. MISTAG LOAD. LOAD 2 NEN LOAD DESCRIPTOR DEMAND R RECEPTACLES- TO IOKVA 100% = 10.0 M MOTORS 100% LW LA RCFST MOTOR 125% = LOCATION T1.115VIL LA WA FED FFCM NOTE CKT 3 7 9 CIRCUT NAME CEILING PANEL - FROCESSNG OBLONG PANEL - PROCESS ECILIP- PROCESS CB SIZE A APF 20 20 LOAD (KVA) R H 0.7 0.4 TOTAL 0.7 A 11 13 15 17 19 21 CEILING Rcua access EQUIP- FROCESS A 20 213 20 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 20 1.6 A 20 23 25 27 29 31 SPARE SPARE SPARE SPARE 3.3 37 41 2 4 SPARE SPARE SPARE SPARE SPARE A 20 20 0.1 1.8 1.8 1.8 1.8 1.8 1.8 0.1 20 20 A 20 PANEL DESCRPTION PANEL A IFS : 100 MAN cB FLUSH SLRFACE SO OD FEEDTHRU A 20 LOAD SumMARY 20 A 0.9 12 14 18 22 24 26 as 32 34 36 38 40 CEILING PANE. - ArrP9-SICNING CEILING PANE- ArrP4SICNING WIREVOU)- ACCESSIONING A 20 20 20 0.4 1.6 0.4 04 0.4 A 0.5 csurz Cams PA CELING PANE -ACCESSIONING WREIOLD- GROSSING WALK INOCNCENSOR SPARE SPARE SPARE SPARE SPARE 42 POTESMEMAPial 1. SPARE 20 0.4 A 20 20 0.4 0.4 0.6 0.4 0.4 OA A A A 20 20 20 20 20 1.7 1.7 0.9 LOAD DESCRIPTION HEAT KVA : MOTOR KVA : 1.8 KITCHEN : 1.8 OTHER WA : 16.2 RASE A KVA : PHASES KVA : AMPS : PHASE C KVA : 10.0 83.0 8.7 72.8 7.5 62.3 CONNECTED LOAD LEMAN) LOAD CENLA ND M ACTORS LM LARGEST MOTOR 0 OTHER 100% 50% 100% 100% 12696 100% • • 6.3 0.1 2.1 0.1 1.8 16.2 KEYPLAN EL19-0949 CITY OF ILI:Writ_A 2 Nickerson Street Suite Slauttle, WA PRECISION ELECTRIC GROUP INC 15323 NE 90th Street Phone: 425-823-8600 Fax: 425-823-8655 ICCASE ir ENGINEERING Consulting Electrical EngineerS 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 A MECHANICAL CHANGES 11-13-19 A LIGHTING CHANGES 11-21-19 12-19-19 1-10-2020 CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S. Tukwila, WA CONSTRUCTION DEVELOPMENT OW of TallyeiN laJILDING MASON SPACE FOR OFFICIAL CITY USE ONLY PANEL SCHEDULES DATE CHECKED BY PROJECT NUMBER 11/11/2019 TN 19256 E10.3 A 25 27 CEILING PANEL - NCROTOW 31 SPARE 33 35 37 39 41 0.4 2 3 4 PERMIT CENTER SABA 2 Nickerson Street Suite Settle, WA E E E D C B A 01 January, 2000 (N) PANEL P9' PROJECT NAME CELL NEnx PROJECT#. 19256 LOCATION TUKWILLA WA F®FROM NOTECKT PC CIRCUIT NAME CB SIZE LOAD (KVA) TOTAL PANEL CESCIIPTION 0 AMP P R H M L K 0 1 TU-2-12 A 30 1 5.0 6.0 PANEL AMPS F{�B7 AMPS L- LVOLTS: L- N VOLTS PHASE IMRE MLO. MAIN CB FLUSH SURFACE ISO GND FEE13THRU_ : : : : X I 250 250 480 277 3 t 3 5 ..'7 T112-01 B C A 50 60 60 1 1 1 10.0 5.0 8A -- t + _ 10.0 60 " 6.0' TU-2-13 TU -2-03 9 7OE2-02 B 30 1 10.0 10.0 11 TL12-04 G 50 1 10.0 10.0 ---- 13 15 TU-2-06 TLL2-06 A B 50 6 16" 1 1 ......_... 10.0 2.0 -- i0.0_ - 2.0 -"- - 17 TU-2-07 C 30 1 6.0 6.0 19 TU-2-22 A B 2D 15 1 1 4.0 1.0 4.0 1.0 21 TU-2-21 23 TU.2-27 C 30 1 5.0 5.0 --- 25 27 27 TU-2-23 TU-2-25 A B 20 15 1 1 5.0 1.3 -�' --- 5.0 1.3 29 TU-2 28 C 15 1 1.3 1.3 --E-3 - 31 35 SPARE SPARE _____,.,........._._.._...._.....__... SPARE_.._.........._................._..__.---................._..............,_ A B....I-f- C 20 20 2....' 1 ------ -'-----}------ ---" 37 39 SPARE SPARE __.__......_..._.._._--".._.._.._._.._.......__... A B C 20 20 20 1 1 '2 ----'- LOADSUSI MARY ---- 41 SPARE---_.._.............-"------..._._...__.__......_....._... FECINA : MEAT KVA : 171.6 MOTOR KVA : LGHTNG KVA : KITCHEN KVA OTHER KVA PHASEA KVA! 61.0 ANDS : 2202 RIASE B KVA : 55.3 AMPS : 199.6 FHASECKVA : 55.3 AMPS : 199.6 TU -2-10 A B 30 ...30. 1 1 ...__ 5.0 --- 6.0 4 TLL2-11....'.'..'."...............................__.__._..._......._. 8.0 6.0 6 TL.2-26 C 20 1 4.0 I 4.0 ......._"-" 8 10 12 TL12-20 A _ B C 40 _ 40 40 50 1 _.._ 1 ..-__........0.,.._. 1 ....... 7.0 ......... 8.0 10.0 _ ................_.........a.. I ' .... _ .....,.._...__....._. -''I I 7.0 ___ 8.0 ...._ .0.... 10.0 T112-0B ....--'-- 14 TU-2-24 A B C 20 21 23 1 1'---...... 1 4.0 ...10.0 _. ...__. 8.0 I i r•...__...__L...___..,....,......_. ___.._.. i.. 1 I 4.0 ....10.0... 8.0 TU-2-19 ___ TU-2-14 ----'--..... 20 TU -2-16 A 50 1 9.0 i 1 ' 9.0 22 24T112-17 7U-2-15 �--- B 40 1 8.0 1 i . �_._.._...i.__.___ r---� ; 1 8.D _._..___. 8.0 C 30 9�-�--8.0 26 Tll•2-18 A 90 1 6.0 1 6.0 .._ 28 -55 SPARE SPARE --. __ B 20 1 1-_--____..........._.__ i --._........ ......_........_. C 20 32 SPARE A 20 1 CONNECTWLOAD _._......_ - 34 .-38 38-SPARE SPARE B 20 1 1 .-. -_._._........_ __`- T__.._._ }.-1-- 7 . INA : 171.6 AMPS : 206.3 SPARE- ...... - --- A... C 20 20 DEMAND LOAD 40 SPARE B 20 1 - KVA : 171.6 ANDS : 206.3 02 SPARE C 20 1 NOT ESIREMARKS : 1. 2. 3, OEMANO I DVERBITY FACTORS LOAD DESCRPTIDN CEAMND R RE(EFrA0.S-TOI0KVA 100% _ REMAINING OVER 10KVA 50% • H HEA1N'3 100% a 171.6 M MOTORS 100% _ LM LARGEST MOTOR 125% a L LIGHTING 125% • K IOTCHEN 100% • 0 OTHER 100% _ (N) PANEL 'ELEV' PROJECT NAME PROJECT*. LOCATION FED FROM NOTECKT NO CIRCUT NAME CBSZE LOAD(KVA) PANE- DESCRIPTION SAMPIP R H M L K 0 TOTAL 1 REC- ELEV PIT A 2D 1 0.2 0.2 PANELAMPS : 100 __--- 3 5 T t) REC- ELEV RM B 20 1 0.2 0.2 FEBCERAMPS L- LVOLTS: L- NVOLTB FIRS! VICE A.LC ML.O.X_ MAN C13 FLUSH SUJRFACt GO GND F�TFRl1 : : : : : 60 208 120 1 3 10K A 20 1 1 _... ._._._-.._ _-----"-"- SPARE B .20.1 _ ...__ .....u......... -'--......... SPARE SPARE A 20 1 ,........__i 11 13 3 S SPACE SRAEC B - 1 A - 1 SPACE B _ 1 17 SPACE A - 1 1 ____..........._....__.._.__._...__....... .,_-_.., .........__. ._____..t.._. .... ._ ........._. _. 171 I 1 LOAD SUM MARY I [TIDILL a[C IOL11 RECINA : 0.4 HEAT Ka: MOTOR KVA : LIGHTING KVA : 0.3 - 2 4 LTS- ELEV CAB A 15 1 0.2 ; I 0.2 LTS- ELEV RM B 15 1 0.1 0.1 6 LTS-ELEV PIT A 15 1 0.1 D.i 8 10 12 SPARE B 20 1 A - 1 -'- SPACE WTCFEN KVA : OTFBi KVA PHASE KVA : 0.5 AMPS : 3.9 PHASE B KVA : 0.2 AMPS : 2.0 B - 1 ...------- SPACE 14 SPACE A - 1 B 1 --'- 16 SPACE --._._. ---"--...---_...__._........__..._...__.._._......__.._._A .......................-"-�_.-'- A - 1 - 18 SPACE ......._ I CONNECTED LOAD RNA : 0.7 AMPS : 3.4 MONO LOAD .. .. KVA : 0.8 ANDS : 3.8 NOTE 1, 2. 0. 8IRB1ARK8 : DEAAND / DVER3ITY FACTORS LOAD CESCRIPTDN CEMANO R RECEPTACLES -TO10KVA 100% • 0.4 REAANNG OVER 10KVA 50% • H I£ATNG 100% = M MCTCRS 100% = LM LARGEST MOTOR 125% • L LIGHTING 125% = 0.4 K KITCHEN 100% _ 0 OTHER 100% = (N) PANEL'SB6' PRO.ECTNANE: CELLNETIX PROJECTG. 19256 LOCATION: TU(WILLA WA FED FROM 1QTE CKT NQ C1ITCUT NAME CB SIZE LOAD (KVA) PANS DESCRIPTION B AI P P R H M 1 L; K 0 TOTAL 1 Cat* PANEL. 0RJ83N0 A 20 1 I 1.5 1.5 PANEL AMPS : 100 3 CEI.NG PANEL GRDSSNG B 20 1 0 8 0.8 FffOEti AMPS : 100 5 CaNG PANEL GibOSSNO C p 1 ---"�'--` -" 15 1 5 L- L VOLTS : 208 7 7 CILNG PANEL GROSSING A 20 1 -----1-_-.-- 0.8..' 0 9 _ L - N VOLTS : 120 9 CELLO PAW. -- GROSE** ---- B 20 1 7 i 1.6 - 6... PHASE : 3 11 CaNG PANEL - GROSSING C 20 1 j..L. 1.5 ' 5 WRE : 4 13 C1iNG PANEL - OROSSNG A 20 1 1 1 0.8 08 ....._._..._..0P _._._....-......._..-'-----....1.._..._._... L ...___•_ .... .. GROSSING C aNG PANEL GROSSING _.. 8 16 20 1 j 1J5 1.5 17 MNGPANEL -C SSNO C 20 1 I 0.8 0.8 18 SPARE A 20 1 ' M.L.O. X 21 SPARE....._..._ - 8 20 1 ...........__.._... M41NCB 23 SPARE C 20 1 FLUSH_ 25 SPARE A 20 1 SIRFACE X 8OGND- '---- -' 27 . ....._....._ SPARE.._.-_ -'- B 20 1 29 SPARE C 20 1 FEED.TFRU_ ------33 31 SPARE A 20 1 S ........ .......;...._.__.. _........... SPARE ..... C 20 1 ..._ 37 SPARE A 20 1 .__...---"- d_-__._... ......._. LOADSUMMARY _....... 39 SPARE._.,_.--".._-.-_ B 20 1 -... � IfO,tL a.L it: Tl]V9J 41 SPARE.._..._...__ C 20 1 I 2 2 CELNG PANEL - GROSSING A 20 1 1 I 1.6 1.5 RBD KVA : _'. . 4 20 7 ...._..._..__ .. {__...._._{...._..._._-0.8 0.8 FEAT KVA : _ Cate PANEL - GRDSStNO B 6 CaNG PANEL - GROSSING C 20 1 1.5 1.5 MOTOR KVA : 8 CIiNG RANEL - GROSSING A 20 1 0.8 0.8 LIGHTING KVA : _.._.... g_. 21 1.5 1.5 KITCHEN INA: --- 10 _......._ __._...__._ (S.N'-RAFEL- GROSSING ._._..L__-__.__ _ 12 .......................... CaNORAFEL-Gf/3$.ANO „. C 20 . 1 ......_.�Y 0.8 0.6 OTHER KVA: 26.0 14 COLIC Rua -GROSSING A 20 1 -------0.8 1.5 1.5 16 CaNG PANEL-GRJSSNG B 20 1 .__....� 0.8 PHASEA INA : 9.2 18 CBNGPAFE.-GROSSING C 20 1 -_--- 1.5 1.5 AMPS: 76.7 20 CaNGPANEL -GROSSING A 20 1 0.8 0.8 PHASE BKVA : 8.4 22 CEILING PANEL- GRDSSNG 8 20 1 1.5 1.5 AMPS: 70.0 -----' 21 Cat* PANEL- GROSSING ........... C 20 1 0.8 0.8 PRASE KVA : 34 26 CEILING PANEL - GFOSSNG A 20 1 1.5 1.5 AMPS : 70.0 ..__._._ 28 SPARE __._...................._.......____.___......._._............. 6 20 1. ....._. ---i 30 SPARE C 20 1 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA : 26.0 '--- 36 SPARE C 20 1 --�^ AMPS : 72.2 38 SPARE A 20 1 1 C9ATND LOAD 40 SPARE B 20 1 KVA : 26.0 42 SPARE C 20 1 AMPS : 72.2 NDTF8/RBIARKS : DEMAND / DVERSITY FACTORS 1. LOAD DESCRIPTION DEMAND 2. R RECEPTACLES - TO 10KVA 100% _ 3_ RBAAINNO OdER 10KVA 50% H BEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% - L LKi4TING 125% • K KTTO€M 100% • 0 OTHER 100% = 26.0 KEYPLAN ELi 9-0949 2060957 6400 www.sabarch.com PRECISION ELECTRIC GROUP 15323 NE 90th Street Redmond, WA 98052 Phone:425-823-8600 Fax:425-823-8655 E t CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax 425-402-9402 E E CELLNETIX FACILITY RELOCATION 12501 E. Marginal Way S Tukwila, WA D C CONSTRUCTION DEVELOPMENT r ; OM L r IOF-iWlr '70O'Tileo. RAFv::, C - it o City of Tulcw42 BUILDING DIVISION L J SPACE FOR OFFICIAL CITY USE ONLY PANEL SCHEDULES B DATE 11 /11 /2019 CHECKED BY TN PROJECT NUMBER 19256 E10.4 A RECEIVED CITY OF TUKWILA NOV 1 4 2019 PERMIT CENTER