Loading...
HomeMy WebLinkAboutPermit EL19-0958 - SHASTA BEVERAGES - DATA SWTICHBOARD, DISTRIBUTION BOARD AND SINGLE LINE, EQUIPMENT LABELING & LOAD LOCATIONSSHASTA BEVERAGES INC 1227 ANDOVER PARK E FINALED 02/20/2020 ELI 9-0958 Parcel No: Address: City of Tukwila a t of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98138 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 3523049072 Permit Number: EL19-0958 1227 ANDOVER PARK E Project Name: SHASTA BEVERAGES, INC Issue Date: 2/19/2020 Permit Expires On: 8/17/2020 Owner: Name: Address: NATIONAL BEVERAGE CORP 8I00SVV1OTMSTSTE4000' PLANTATION, CA, 33324 Contact Person: Name: RICH GIAMBITTI Phone: (505) 503-0602 Address: l3961CENTRAL AVE ' CHINO, CA, 91710 Contractor: Name: DIAMOND BAR ELECTRIC INC Phone: (909) 860- 590 Address: I3961CENTRAL AVE ' CHINO, CA, 91710-5556 License No: AEC3532 Expiration Date: 4/2/2021 Lender: Name: Address: I 1 DESCRIPTION OF WORK: REVISE SCOPE OF WORK TO PERMIT EL19-0260 (FINALED 9-5-19) NEW DATA SWITCHBOARD DISTRIBUTION BOARD & SINGLE LINE DRAWING DIAGRAM SHEET E4, MADE CHANGES TO EQUIPMENT LABELING & LOAD (3) LOCATIONS. Valuation of single farnily: $0.00 Valuation ofmf/comnn: $ll'OUO.00 Type of Work: SERV CHNG Fees Collected: $419.54 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 1 nternational Residential Code Edition: nternational Mechanical Code Edition: Unitorm Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 20172017 2015 i Date:����/�e� v....o6o 1 hearby certify that have read arid examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or Iocal laws regulating construction or the performance of work, 1 am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: rit This permit shall become null and void if the work is not commenced within 180 days for the elate of issuance, or if the work 15 suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 NEC, arid requirements for electrical installations, Chapter 295-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefornot valid. 7: Any change in the scope of work described by the electrical work permit shall require dditional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS IEQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH'|NELE[TR|[AL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://wvvvv.TukwilaWA.gov Electrical Permit No. Llq- ocese, Project No. r Date Application Accepted: 1-ig -( 5'—k9 -)o Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 1 22'7 t' oo %J Q ei4r(`()- L Suite Number: Floor: Tenant Name: SONSTrh 641C(I-.h.t.L PROPERTY OWNER Name: IgArc t4 6.vc(L .e.,L C 4). Address: Cal( c3 �� 107 t; ,S "5 —L q City: LS , l�. , State: t p,. Zip:33 CONTACT PERSON - person receiving all project communication Name:(2 .a- Glk.v..vcC"\ Address: LobA Yt Address: l 39 (' C ; tz.A. h J g.._. City: C-Ikv-5i� State: Zip% (23 Phone: ,_ Fax: SO) • "Na5 -0(402— 7(402Email: Email: C t C - h Q cLC, ,ZI"s8 t ..ce lec_-1f, .._c New Tenant: El Yes '..No ELECTRICAL CONTRACTOR INFORMATION Company Name: VIN A< BA l -L i Q,c._ Address: LobA Yt City:�� State: e_k Zip:q \7 r u Phone:Fax: X09 • Hca(D• (059 9 09 • rho - 513 Contr Reg No.: Exp Date: Tukwila Business License No. Valuation of Project (contractor's bid price): $ 1 2, ex- . UJ pp�� Scope of Work (please provide detailed information): ! 1S tct�i c iEE S-Tc� Com\� - 0 2(c - IJ1`N�.�u �1hC�Q klr� 51-kt-E_ " - ><y G4-4l7c_(S LI Qct_,,)(_ - LUAA (3) LcLn--t ti ‘IJ %. Will service be altered? 11" -Yes ❑ No Adding more than 50 amps? [Yes ❑ No Type ofUse: Type of work: ❑ New 0 Addition EI' Service Change 0 Remodel 0 Tenant Improvement O Low Voltage 0 Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light W:\Permit Center \Applications•Handouts\Permit Applications\PDF's\Electrinai Permit Application Revised 1-17-19.docx Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE O New single family dwellings $180.00 (including an attached garage) O Garages, pools, spas and outbuildings $120.00 ea 0 Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES O Service change or alteration $120.00 (no added/altered circuits) O Service change with added/altered circuits $100.00 number of added circuits $10.00 ea O Circuits added/altered without service change $60.00 (up to 5 circuits) O Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea O Meter/mast repair $80.00 O Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES LJ Temporary service (residential) $60.00 O Temporary service (generator) $90.00 O Manufactured/mobile home service $100.00 (excluding garage or outbuilding) O Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: I C--3 Av-ok Day Telephone: 0 • SO4c • Cit.C.Or2"") Mailing Address: • Date: 0.19.19 3q . C_O-1-30 City W: \Permit Cent eMppfications-HandoutskPermit Applications \PDFM,Electrical Permit Application Revised -17-19.docx - State 917/0 Zip Page 2 of 2 Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $419,54 EL19-0958 Address: 1227 ANDOVER PARK E Apn: 3523049072 $419.54 Credit Card Fee $12.22 Credit Card Fee R000.369,908.00.00 0.00 ELECTRICAL $391.65 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 PLAN CHECK FEE R000,345.832,00.00 0.00 $78.33 TECHNOLOGY FEE $15.67 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R19106 R000.322.900.04.00 1 0.00 $15.67 $419.54 Date Paid: Tuesday, November 19, 2019 Paid By: RICHARD GIAMBIATTI Pay Method: CREDIT CARD 09178G Printed: Tuesday. November 19. 2019 10:23 AM 1 of 1 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1878 CITY OF TUKWILA Date: 11/19/2019 10:23:05 AM CREDIT CARD SALE VISA CARD NUMBER: **********3961 K TRAN AMOUNT: $419.54 APPROVAL CD: 09178G RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy City of Tukw Department of Community Development December 19, 2019 RICH GIAMBITTI 13961 CENTRAL AVE CHINO, CA 91710 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL 19-0958 SHASTA BEVERAGES, INC - 1227 ANDOVER PARK E Dear RICH GIAMBITTI, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. • CORRECTION/ #1 1). VP PALLETIZER INDICATES 100A LOAD WITH 40A OCPD AND #8 AWG CONDUCTORS. REVISE. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. 1 have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. ELI9-0958 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0958 DATE: 01/06/2020 PROJECT NAME: SHASTA BEVERAGES, INC SITE ADDRESS: 1227 ANDOVER PARK E Original Plan Submittal X Response to Correction Letter # Revision # before Permit Issued Revision # after Permit -Issued DEPARTMENTS: ..1?) ii\TO Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator u PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 01/09/2020 Structural Review Required REVIEWER'S INITIALS: DATE: Lil APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 02/20/2020 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire 0 Ping PW 0 Staff Initials. 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-0958 DATE: 11/19/19 PROJECT NAME: SHASTA BEVERAGES, INC SITE ADDRESS: 1227 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Y Corl Building Division Public Works Fire Prevention Planning Division r Structural Permit Coordinator AIN PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Corrections Required DATE: 11/21/19 Structural Review Required DATE: Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 12/19/19 Notation: 4 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 12-10i-4 Departments issued corrections: Bldg -- Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2011 Date: 1 (10 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www,TukwilaWA.gov ReezetifpD mo6231i Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail,fax, etc. [1] Response to Incomplete Letter # Plan Check/Permit Number: EL19-0958 Response to Correction Letter # 1 LI Revision # after Permit is Issued n Revision requested by a City Building Inspector or Plans Examiner LI Deferred Submittal # Project Name: Shasta Beverages, Inc Project Address: 1227 Andover Park E Contact Person: ei (— 14 (..tAr-46, TT Summary of Revision: &i3—c_T Tt.) C -- ENT Phone Number: IS C-Lfve(04 (00A t4- 1 A Sheet Number(s): E- - "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: LI Entered in TRAKiT on CAUsers \bill -r \Desktop \Revision Submittal Form.doe Diamond Bar Electric Inc OWerliropo Labor & Industries (https://lai,wa.uov) Contractors 0 Diamond Bar Electric Inc Owner or tradesperson Principals Bogy, Matthew 8, PRESIDENT Bogy, Therese L, VICE PRESIDENT CT Corporation System, AGENT Doing business as Diamond Bar Electric Inc WA UBI No, 604 355 870 13961 Central Ave CHINO, CA 91710 909-860-6590 Business type Corporation Governing persons MATTHEW B BOGY THERESE L BOGY; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. DIAMOBE812DH Effective — expiration 04/02/2019— 04/02/2021 Designated administrator ST CLAIR, DENNIS RYAN License type Electrical Administrator Bond Developers Surety & Indem Co Bond account no. 668031C Active Meets current requirements. Active Meets current requirements. License no. STCLADR994PF $4,000.00 Received by L&I Effective date 04/02/2019 03/01/2019 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Page 1 of 2 • 1,,s; T1:21[=_AfIA C <Q711.12,T 111" -_-=TIT A TkifnnvQ lira -12,C A IV= 1 PI 1 /1(1)(1 1 2 1 3 1 4 5 1 6 1 7 1 8 DB - A CONT. FROM SEE DWG. E-1 ‘/r o— 2 - 600 KCMIL Cu. PER 0 2 - 250 KCMIL N Cu. 2 - 4/0 AWG GND. Cu. 2-4"C. Approx. 350' VD = 1.1% MAIN CIRCUIT BREAKER 0 O O 800AF 800AT 3P, 4W 65 KAIC 80% RATED SQUARE D Type PJ *Ammeter trip Unit, Long Time, Short Time, Instantaneous, Ground Fault Note: (Panel /Equip. Name) (Amp Rating) (kA Rating) (Make & Model) (N) DISTRIBUTION BOARD a 60AF 60AT Q 3P, 3W Type BJ 80 /o RATED 40— 1 - #4 Awg. Cu. PER 0 1 - #8 Awg. Gnd 1-1"C Approx. 70' VD = 0.5% (N) BUSSE DEPALL. 55 A,3PH 480 VAC a 100AF 100AT Q 3P, 3W Type BJ 80% RATED 1-#1Awg. Cu. PER 0 . 1 - #6 Awg. Gnd 1 - 1 1/4" C Approx. 110' VD = 0.6% (N) ALVEY PALLETIZER 100 A,3PH 480 VAC (N) DISTRIBUTION BOARD A - SINGLE LINE DIAGRAM 1000A BUS RATED, 480Y/277 VAC, 3PH, 4W, 65KAIC, NEMA 3R SQUARE D SERIES 2 QED-2 SWITCHBOARD O 125AF O 125AF 125AT 125AT 4 3P, 3W 4 3P, 3W Type BJ Type BJ 80% RATED , 80% RATED 44- 1 - #1 /0 Awg. f PER 0 . 1 - #6 Awg. G 1-11/2"C Approx. 140' VD = 0.7% (N) WARMER 125 A,3PH 480 VAC Cuff— 1- #1/0 Awg. PER 4' nd. 1 -#6 Awg. Gnd. 1-11/2"C Approx.160' VD = 0.7% (N) DOUGLAS 125 A,3PH 480 VAC a \ 100AF 100AT Q/) 3P, 3W Type BJ 80% RATED Cu. 1 -#1 Awg. Cu. PER 1 - #6 Awg. Gnd 1-11/4"C Approx.200' VD = 1.1% (N) DUO DOZER 125 A,3PH 480 VAC -1 J O\ 250AF 250AT 4 3P, 3W Type JJ 80% RATED 1 -#250 KCMIL Cu. PER $ . 1 - #2 Awg. Gnd. 1 -2 1/2" C Approx. 130' VD = 0.6% (N) CONVEYOR. CONTROL PNL 250 A,3PH 480 VAC O 30AF 3OAT 9/ 3P, 3W 30F J 30AT 93P, 3W Type BJ I Type BJ 80% RATED 180% RATED 1 - #10 Awg. Cu. 1 -#10 Awg. PER • PER 4) 1 - #10 Awg. Gnd. 1-3/4"C Approx. 160' VD=2% (N)NORDSON GLUE UNIT - DOUGLAS 30 A,3PH 480 VAC O 30F 3OAT 9/ 3P, 3W Type BJ 180% RATED Cu.Q— 1 -#10 Awg. PER 0 1 - #10 Awg. Gndi 1 - #10 Awg. Gnd. 1-3/4"C 1-3/4"C Approx.200' Approx. 240' VD=2.6% VD=2.7% VP WRAPPER 30 A,3PH 480 VAC (N) CAN DRYER 30 A,3PH 480 VAC 100AF 100AT Q/ 3P, 3W Type BJ 80% RATED SPARE Cu.4r 1 -#1 Awg. Cu. 4.— 1-#1 Awg. Cu. I PER 0 PER • 1- #6 Awg. Gnd. 1 - #6 Awg. Gnd. 1-3/4"C 1-11/4"C Approx.140' Approx. 10' VD=1.6% VD=>1% 75KVA XFMR ����YYYYyyyyYYYY���� PRI. 480V SEC. 120/208 6"b1 - - 1- #3/0 Awg. Cu. PER $ I 1 -#3/0 Awg. N Cu. 1 1 - #2 Awg. Gnd. 1 - 2 1/2"C. (N) 120/208V PANEL FEED 3PH, 4 200 A4W CONT. (N) DISTRIBUTION BOARD - A 1000A BUS RATED, 480Y/277 VAC, 3PH, 4W, 65KAIC, NEMA 3R SQUARE D SERIES 2 QED-2 SWITCHBOARD CONTINUE BELOW LEFT 60AF 60AT 3P, 3W 6 I E COPY eyn } ` rmit N•t. 1-7.O FROM ABOVE RIGHT O\ 0 40AF 40AT 3P, 3W Type BJ 80% RATED 30AF 30AT 3P, 3W Type BJ 80% RATED 30AF O` 30AF 30AT 1 30AT 3P, 3W O 3P, 3W Type BJ Type BJ 80% RATED 80% RATED O \ 30AF 11 30AT O 3P, 3W Type BJ 80% RATED Ol 30AF Ol 100AF J 30AT J 100AT O 3P, 3W O 3P, 3W Type BJ Type BJ 80% RATED 80% RATED O\ 100AF j` 100AT O 3P, 3W Type BJ 80% RATED 100AF 100AT 3P, 3W Type BJ 80% RATED O�O 100AF 100AT 3P, 3W Type BJ 80% RATED O\ 100AF /) 100AT O 3P, 3W Type BJ 80% RATED O 100AF \ 100AF O l ) 100AT J O 3P, O 3P,100AT 3W Type 3WB 80% RATED Type BJ 80% RATED O�O 250AF 250AT 3P, 3W Type JJ 80% RATED SPARE SPARE SPARE SPARE SPARE PLANT NOTES 0 OBTAIN A GROUND FAULT TEST FROM A CERTIFIED TESTING AGENCY & PROVIDE TEST REPORT TO BUILDING INSPECTOR. 0 3/4" C, 1 #6 GND TO BUILDING STEEL WITH (2) 3/4" x 10FT GROUND RODS AS SUPPLEMENTAL GROUND. SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SEPARATE PERMIT RE IRED FOR: (Mechanical 2. Electrical Plumbing 0;3' Gas Piping City of Tukwila BUILDING DIVISION CORREQTION !TR#__ rLviow8 PSE XFMR MSS (RECEIVED CITY OF TUKW LA JAN 06 2020 PERMIT CENTER A A Electrical Englnee Services Diamond Bar Electric, Inc. 13961 Central Ave. Chino, CA 91710 Phone: (909) 860-6590 Fax: (909) 860-3173 www.DiamondBareechic.com C-10 A#786172 B C D "lissing or = ile: „\„\„\, Shlpptl 1 TUKWILA, WA 98188 E DESCRIPTION W a r PROJ. NUMBER 0-620-18 PROJ, MAN. MATT BOGY F DATE 3/7/19 NEW 800A SWITCHBOARD - DISTRIBUTION BOARD A SINGLE UNE DIAGRAM BYt R. VILLANUEVA SCALD NTS SIZE' D DRAWING NUMBER E-4 2 3 4 5