HomeMy WebLinkAboutPermit EL19-1067 - LENSCRAFTERS - PANELS, LIGHTING OUTLETS, SWITCHES AND MISCELLANEOUS LOW VOLTAGELENSCRAFTERS 416 SOUTHCENTER MALL Apn: 9202470130 FINALED 05/04/2021 ELI 9-1067 City 7� Tukwila of " K�m^mwUoa t of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206'431'3570 Inspection Request Line: 206-438-9350 Web site: http://www.TukwitaWA.gov Parcel No: 9202470130 Address: 416 SOUTHCENTER MALL Project Name: LENSCRAFTERS ELECTRICAL PERMIT Permit Number: EL13-1067 Issue Date: 8/27/2020 Permit Expires On: 2/23/2021 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: License No: Lender: Name: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, MN, 92013 TIM SCHENK 11Z0EOOST#211,BLOOMINGTON, MN, 55420 Phone: (952) 345-6040 D C ELECTRIC INC Phone: (206) 940-4963 Z3I1763AVE VV,M0UmTLAK[ TERRACE, WA98043 D[ELE[|924ND Expiration Date: 8/18/2022 ''' DESCRIPTION OF WORK REMODEL OF THE EXISTING LENSCRAFTERS VISION CENTER IN THE MALL. EXISTING METER, RELOCATE ONE PANEL, ONE NEW PANEL, NEW LIGHTING OUTLETS, SWITCHES & MISC LOW VOLTAGE. Valuation of singe family: $0,00 Valuation of mf/comm: $105,919.00 Type of Work: TENANT IMP Fees Collected: $2,256.39 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Buliding Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: 2017WA State Energy Code: 2017 2017 2015 Permit Center Authorized Signature: //(A/14.t //(/ /rt"-'.( tv Date: 06 /3--14.6a0 1 hearby certify that 1 have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to gve authority to violate or cancel the provisions of any other state or local Jaws reguIatin construction or the performance ofwork. 1 am authorized to sigri and obtain this development permit and agree to the conditions attached to this perrnit. Signature:/�/�/|l~� [ �/~ Print Name: ��' Da�6�/�// �mv�� This permit shall become null and void if the woris not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQURED Permit Inspection Lirie: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWI A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. aict-/o(f/7 Project No. Date Application Accepted: 3o -(c) Date Application Expires: (For office use only) ELECT RICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: -ecaLli 0 o Site Address: 411 b SounKeirea. Alas- Suite Number: 6% Floor: Tenant Name: 1.—er4scArw-cus PROPERTY OWNER Name: kriesrPiELD Address: 2.((xl • 5w cv‘.CKYll--11. flitILL. City: State: , STEA a LET. vl zipeActttits CONTACT PERSON — person receiving all project communication Name: 1-1 rn 5 G lAE..r.1 e•-. Address: 112, E•90 _ TE21) City: 6Lizio rilkr4(rckw State: tr 7 i ....p:srba Phone: (s.t4s-.664-Q1 Fax: A-sz . sstit .49m Email: jrl MS e. eAate, New Tenant: 0 Yes 531 ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: ...- 1 60 Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 10 Scope of Work (please provide detailed information): (EMIQEL o fl4 E-Al5nror Leis casfre-Ls \J 5%r4 ceryrel E. -MSc -WV, frIETW. .e.ELExAM Qfe enrife-k.. 011E KEW 81(16L, 0E14 UG(41-16. (IalZSStI irCi4t5 Pt-. Lc NokcixIkS Will service be altered? 0 Yes Lj No Type of Use: Type of -work: 0 New 0 Addition ON Low Voltage 0 Generator Property Served by: 0 Puget Sound Energy 0 Seattle City Light Adding more than 50 amps? [:1 Yes [2' No Service Change 0 Fire Alarm WAPermit Cemter1Applications-HandautsWesmit Applications PDFs Eirctrical Permit Application Revised 1-17-19.docx izt Remodel fEC Telecommunication a Tenant improvement 0 Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $180.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $120.00 ea ❑ Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $120.00 (no added/altered circuits) ❑ Service change with added/altered circuits $100.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $60.00 (up to 5 circuits) ❑ Circuits added/altered without service change ..... $60.00 (6 or more circuits)...............................,..,,510.00 ea ❑ Meter/mast repair $80.00 ❑ Low voltage systems 560.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $90.00 ❑ Manufactured/mobile home service $100.00 (excluding garage or outbuilding) ❑ Carnivals $100.00 Number of concessions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value off Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: 11 M $C1AEdiK- Day Telephone: Mailing Address: I124 E Date: (Z(-af(c1 q sz .34s. 6Q40 tit (1 , Gum'Mr( rt S54?A ity W:Wennit Center\Applications-HandoutslPermit ApplicationslPDFskElectrtcal Permit Application Revised 1-17-19docn State Zip Page 2 of 2 Receipt Number ., DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY .y .44 PAID ,... $3,047.74 D19-0411 Address: 416 SOUTHCENTER MALL Apn: 9202470130 $2,320.90 DEVELOPMENT $2,320.90 PLAN CHECK FEE R000.345.830.00.00 0.00 $2,320.90 EL19-1067 Address: 416 SOUTHCENTER MALL Apn: 9202470130 $433.92 ELECTRICAL $433.92 PLAN CHECK FEE R000.345.832.00.00 0.00 $433.92 M19-0214 Address: 416 SOUTHCENTER MALL Apn: 9202470130 $218.42 MECHANICAL $218.42 PLAN CHECK FEE R000.322.102.00.00 0.00 $218.42 PG19-0198 Address: 416 SOUTHCENTER MALL Apn: 9202470130 $74.50 PLUMBING $74.50 PLAN CHECK FEE TOTALPAID BY RECEIPT: R19409 R000.322.103.00.00 0.00 , $74.50 ,IIEES , $3,047.74 Date Paid: Monday, December 30, 2019 Paid By: ELDER -JONES BUILDING PERMIT SE Pay Method: CHECK 82194 Drintarl• NAnnriaw rwprnhpr .Rn ?ni c 114 PM 1 of 1 DESCRIPTIONS ACCOUNT QUANTITY I PAID PermitTRAK $6 808 36 p . D19-0411 Address: 416 SOUTHCENTER MALL Apn: 9202470130 $3,755.64 DEVELOPMENT $3,577.11 PERMIT FEE R000.322.100.00.00 0.00 $3,570.61 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $6.50 TECHNOLOGY FEE $178.53 TECHNOLOGY FEE R000.322.900.04.00 0.00 $178.53 EL19-1067 Address: 416 SOUTHCENTER MALL Apn: 9202470130 $1,822.47 ELECTRICAL $1,735.69 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,735.69 TECHNOLOGY FEE $86.78 TECHNOLOGY FEE R000.322.900.04.00 0.00 $86.78 M19-0214 Address: 416 SOUTHCENTER MALL Apn: 9202470130 $917.35 MECHANICAL $873.67 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $840.52 TECHNOLOGY FEE $43.68 TECHNOLOGY FEE R000.322.900.04.00 0.00 43.68 PG19-0198 Address: 416 SOUTHCENTER MALL Apn: 9202470130 $312.90 PLUMBING $298.00 PERMIT FEE R000. 22.100.00.00 0.00 $263.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 TECHNOLOGY FEE $14.90 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.90 TOTAL FEES PAID BY RECEIPT: R20341 $6,808.36 Date Paid: Thursday, March 05, 2020 Paid By: ELDER -JONES Pay Method: CHECK 82367 Printed: Thursday, March 05, 2020 12:26 PM 1 of 1 CiliW5YSTEMS Permit Number: EL19-1067 Permit Inspections City of Tukwila Applied: 12/30/2019 Approved: 4/27/2020 Issued: 8/27/2020 Finaled: 5/4/2021 Status: FINALED Parent Permit: Parent Project: Details: Description: LENSCRAFTERS Site Address: 416 SOUTHCENTER MALL City, State Zip Code: TUKWILA, WA 98188 Applicant: LENSCRAFTERS Owner: WESTFIELD PROPERTY TAX DEPT Contractor: D C ELECTRIC INC REMODEL OF THE EXISTING LENSCRAFTERS VISION CENTER IN THE MALL. EXISTING METER, RELOCATE ONE PANEL, ONE NEW PANEL, NEW LIGHTING OUTLETS, SWITCHES & MISC LOW VOLTAGE. OX NSPE T ONS SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS SERVICE Jim Benner Notes: UNDERGROUND SLAB Jim Benner 525349 Notes: ROUGH -IN ELECTRICAL Jim Benner 817-729-3559 Notes: 10/13/2020 AM 10/13/2020 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 525349 Notes: PARTIAL APPROVAL/#1 O.K. -SLAB CONDUITS PHASE 1 10/16/2020 AM 10/19/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 817-729-3559 Notes: PARTIAL APPROVAL/#2 O.K. -WALL COVER PHASE 1 11/19/2020 AM 11/20/2020 ELECTRICAL ROUGH -IN Jim Benner PARTIAL APPROVAL 817.729.3559 1 Notes: PARTIAL APPROVAL/#2 O.K. -PHASE 1 HARD LIDS Printed: Thursday, 14 October, 2021 1 of 3 s1 SUPERION Permit Inspections City of Tukwila 12/3/2020 AM 12/3/2020 ELECTRICAL FINAL Jim Benner NOT APPROVED 8177293559 Notes: CORRECTION/ #4 -NOT READY 2/4/2021 AM 2/4/2021 ROUGH IN ELECTRICAL Jim Benner CANCELLED 817.729.3559 Notes: CANCELLED -SLAB INSPECTION WANTED 2/4/2021 2/4/2021 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 525349 Notes: PARTIAL APPROVAL/#5 O.K. -SLAB CONDUITS AND BOXES PHASE 2 2/19/2021 AM 2/18/2021 ROUGH IN ELECTRICAL Jim Benner CANCELLED 817.729.3559 Notes: PER JAMIE ARCHAMBAULT 2/23/2021 AM 2/23/2021 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 817-729-3559 Notes: PARTIAL APPROVAL/#6 O.K. -WALLS & HARDLIDS PHASE 2 3/16/2021 AM 3/16/2021 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 817-729-3559 Notes: PARTIALAPPROVAL/#7 O.K. -T GRID PHASE 2 3/25/2021 3/25/2021 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 525349 Notes: PARTIAL APPROVAL/#8 O.K. -SLAB CONDUITS & BOX PHASE 3 3/25/2021 AM 3/25/2021 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 817-729-3559 Notes: PARTIAL APPROVAL/#8 O.K. -WALLS & CEILING PHASE 3 Printed: Thursday, 14 October, 2021 2 of 3 i1 SUPERION 4/22/2021 AM 4/21/2021 ELECTRICAL FINAL Ji Benner CANCELLED ' 817-72*3559 Notes: Hello, We need to cancel the scheduled electricl inspection set for 4/22 am. It will not allow us to do 50 online and 1 was unable to get through on the phone today. Every time 1 calI the line is busy, so maybe your lines are down? Thank you! Jaimie Archambault Canyon Contracting 2821 Skye Road Washougal vvx9867z T: 360.837.2204 F: 360.837.2205 4/27/2021 AM 4/27/2021 ELECTRICAL FINAL Jim Benner NOT APPROVED 206-940-0509 Notes: CORRECTIONS/ #9 -CONDUIT SUPPORT AT PANELS -GFCI WITHIN 6 FEET OF SINKS -GFCI RESET TO BE READILY ACCESSIBLE AT WATER FOLJNTAIN -BREAKER HANDLE CLAMP FOR EM. LTG. 5/3/2021 AM 5/4/2021 ELECTRICAL FINAL Jim Benner APPROVED 206-940-0509 Notes: APPROVED/ #10 CORRECTIONS MADE O.K. -FINAL Printed: Thursday, 14 October, 2021 3 of 3 Lighting Summary LTG -SUM shinaton State Enerav Code Com hance Forms for Commercial Buildings includingR2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are wite- protected. Project Title: Lenscrafters 0505 Southcenter Mall Date 8/28/2020 Applicant Information. Provide contact information for individual oho can respond to inquiries about compliance form information provided. For Building Department Use Company Name: Company Address: 2441 Crown Pointe Blvd Suamico, WI 54173 Applicant Name: Michael Romes Applicant Phone: 920-445-5007 Applicant Email: mromes@nextore.com Project Description r.1 New Building 0 Addition Ea Alteration 0 No Lighting Scope Include PRW-SUM form (included in envelope forms zorkbook) Kith lighting compliance forms. Interior Lighting System Description Interior Lighting Plans Included Interior lighting is based on LED light fixtures controlled by timeclock and occupancy sensors. VI D FO= COMPLIANCE WITH NFPA 70 - NEC . OCTOC ---J ii ,,0 2 7 2020 City of Tukwila BUILDING DIVISION , Interior Lighting Power Allowance Method 0 Building Area Method Ed Space -by -space Method Select method used in project. Interior Lighting Controls r, n '—' To required All C405.2.1 - C405.2.8 Lighting Controls 0C405.2 Exception 5 Luminaire Level Lighting Controls (LLLC) Additional Efficiency Package Option C406.4 Enhanced Digital Lighting comply oith C406.4, no less than 90% of the total installed interior lighting pover shall complyorth controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in (Awning 0C405.2 thru C405.5 Commercial Lighting Controls 0 C406.3 High Efficacy Lighting 0 R404.1 Residential High Efficacy Lighting. Doelling and units comply Kith: • No Dwelling LPA Units unit lighting complies Kith WSEC Residential of C Cri.TEttifaZrrisions. — Exterior Lighting System Description 0 Exterior Lighting Plans Included _ There is no exterior lighting on this p . ' ' I Ur I UKIMLA SEP 22 2020 PERMIT CENTER Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project . _ Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing -to -remain Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT For exterior lighting projects, include new + existing -to -remain Proposed Tradable and Proposed Non -Tradable Lighting Wattage Interior fighting El 0 interior lighting fixture -SPACE form, exterior lighting fixture tables in LTG Exterior lighting 0 0 wattage in wattage in -EXT form. Lighting Summary, cont. LTG -SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings includingR2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 8/28/2020 Change of Space Use 0 Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting pokier compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting paver compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. 0 No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting ; 50% or more of existing are replaced 0 Less than 50% of existing are replaced 0 Lamp and/or ballast replacement only — existing total wattage not increased 0 . . .. . 50% or more replaced - Total lighting power of new + existing total LPA per Sections C405.4.2 and C405.5.2. Include new Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT Less than 50% replaced - Total lighting pot4er of new + existing the total lighting power prior to alteration. Include new + existing Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or 50% threshold applies to number of luminaires for interior spaces installed wittage for exterior luminaires. Parking garage ; I:3 0 0 -to -remain fixtures + existing -to -remain -SPACE or LTG -EXT -to -remain fixtures -to -remain fixtures LTG -EXT form. and parking garages, Exterior lighting 0 0 0 shall comply Wth fixtures in form. shall not exceed in the Proposed and total Lighting Controls Interior lighting New wiring installed to serve added fixtures and/or fixtures relocated to 0 new circuit(s) New or moved lighting panel 00 Interior space is reconfigured - luminaires unchanged or relocated 0 New wiring or circuit - For interior lighting, provide required occupancy sensor controls per C405.2.1, daylight responsive specific lighting controls per C405.2,5. For exterior lighting, New or moved panel - Provide all applicable lighting controls time st4itch controls per C405.2.2. Reconfigured interior space - Provide all required lighting space. Application specific lighting control provisions per C405.2.5 ; Parking garage 0 ; Exterior lighting 0 C405.2.3, and application per C405.2.7. Wiring and automatic a new interior reconfigured manual controls per controls per C405.2.4 provide required controls as noted for New controls that apply to do not apply to • 1 • .; Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 8/28/2020 Calculation Area M3TE 9 0 New Construction 0 Addition - 0 Addition 0 Spaces where < 50% of 0 Spaces where a 50% of 0 Spaces where the Use Building Department Use LPA Calculation Type 0 Standard 0 Additional Efficiency Package Option C406.3 Reduced Interior Lighting To comply with C406,3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. User Note 4 Maximum Allowed Lighting Wattage"' 134 Location (plan #, room #) Space Type Ceiling Height WIE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) 102, 104, 105, 108, 109, 113, 114, 115 Health care facility: Exam/treatment 8 '-0" 690 1.330 851 111, 112 Restroom: all other 8'-0" 100 0.780 78 106 Office: Enclosed 8 '-0" 149 0.890 133 103 Seating area, general 10'-0" 169 0.930 73 107,110 Corridor: all other 9' -0" 331 0.530 175 116 Health care facility: Medical supplies 9'-0" 48 0.590 28 101 Sales area 1 0 -6" 2288 1.270 2906 101 Sales area v_70 415 1.270 527 Lobby Art/Exhibit Display Allowance from LTG-INMDISPLAYNarc 8 Total Area Retail Display 4140 LTG -INT -DISPLAY PJlowed Watts Ailowance from III 6893 Proposed Lighting Wattage wrE3 Location (plan #, room #) Fixture Description Nam 4‘ 6' 6 Number of Fixtures Watts/ Fixture "DIE 7 Watts Proposed 102 LED Twin Adjustable Downlight (M3 & M3E) 4 39 134 105, , 108 109, 113, 114,115 LED Downlight (DBW) 16 17 272 111, 112 2x2 LED Lens (A2LE) 2 20 40 106 2x2 LED Lens (A2L & A2LE) 2 20 40 103 LED Twin Adjustable Downlight (M3 & M3E) 5 34 168 107,110 LED Twin Adjustable Downlight (M3 & M3E) 8 34 269 116 LED Twin Adjustable Downlight (M3 & M3E) 2 34 67 104 LED Twin Adjustable Downlight (M3) 2 39 67 101 LED Twin Adjustable Downlight (M2, M3, M3E) 24 39 806 Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 3168 5032 !Interior Lighting Power Allowance COMPLIES WITH C406.3 Note 1 - List all unique space types per Table C405.4,2(2) that occur in the project scope. Select space type category from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track fighting, fist the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5- For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum nput wattage of the fixture (not the lamp wattage). For low voltage fighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 tAntt/linnal Inn' nr Rntpr thp wattanP limit of normpripnt rsirrPnt limitinn devirn Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby art/exhibit display fixtures in LTG-INT-DISPLAY form only. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition MI comply as combined with the overall existing building fighting systems, include all applicable existing Space Types and cross interior areas. Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2015 Washington State Energy Code Compliance Forms for Commercial Buildings includin , R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 8/28/2020 General Note - In Sales areas, an increase in lighting paver allowance is permitted for lighting installed specifically for the purpose of highlighting merchandise. Only Sales areas illuminated with eligible merchandise display lighting may be included in the Gross Interior Area under each Retail category. This lighting power allowance is the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts, whichever is less. Proposed retail display lighting wattage that exceeds this allowance is applied to general area lighting. Maximum Allowed Retail Display Lighting Wattage For Building Department Use User Note Watts Proposed Location (plan #, room #) Retail Sales Area Type NOTE i Gross Interior Area in ft2 Allowed Watts per ft2 NOTE 2 Watts Allowed (watts/ft2 x area) NOTE 3 101 Retail 1: All unclassified retail display 2702 0.60 1621 Total Retail With Display Area Maximum 2702 Total Watts Base Allowance Allowance NOTE 4 1621 Retail Display Lighting Retail Display 500 2121 Proposed Retail Display Lighting Wattage NOTES Retail Area Location (plan #, room #) Fixture Description NOTE 6 Number of Fixtures Watts per Fixture NOTE 7 Watts Proposed Retail 1 101 265'-0" Track, LED (El, E2, & E3) 1 3168 3168 RETAIL DISPLAY WATTAGE ALLOWANCE - PER LPA Proposed Retail Display Lighting Totals from LTG -INT -DISPLAY Total Retail Proposed Display Watts NOTE a Retail Display Power Allowance NOTE 9 3168 2121 Retail 1 Retail 2 Retail 3 Retail 4 3168 Note 1 - Select retail sales areas from drop down menu, Only retail sales areas that comply wth C405.4.2.2.1 may be entered in this table. Note 2 - Retail display lighting power afloviences per C405.4.2.2.1, Equation 4-11. Note 3 - Unlit Message - Enter lighting fixture information for this retail sales area in Proposed Lighting Wattage table to generate Lighting Power Allowance. Note 4 - Maximum retail display wattage allowance as calculated per C405.4.2.2.1, Equation 4-11. Note 5 - Only separately controlled retail display fixtures that are independent of general area lighting per C405.4.2.2.1 may be entered in this table. Note 6 - For proposed Fixture Description, list ALL proposed display lighting fixtures. Indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaries with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For lnui vnitana linhtinn anter tha uottano of rho trancfnrmor Fnr lino vnitann trark/h, ,cmav cvctomc entor tha larnar of the affarharl /U. 1/1/11Cly ,V1/111/V, CI /IGO II lc vcattayc 4.11 110 OM I LP 1110 V1-1I.0 ocaurvuuovbaycurer 120 ialyco II/O 01104.1,01.1 luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Total Retail Proposed Display Watts is automatically entered into the Proposed Fixture Wattage table in LTG-INT-SPACE. Note 9 - Retail display lighting power allowance is the lesser of the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts. Retail display wattage allowance is automatically entered in the Maximum Allowed Lighting Wattage table in LTG-INT-SPACE. Note 10 - Enter a unique title for each lobby area in the project that has seperately controlled art/exhibit display lighting. A lobby area title (Column A) and the gross interior sf of the lobby area are are both required to generate the maximum display allowance. Note 11 - Lobby art and exhibitdisplay wattage allowance per Table C405.4.2(2), Footnote c = 0.5 WO. Note 12 - Proposed display lighting totals for each lobby area per information entered into Proposed Lobby Art/Display Lighting Wattage table. Note 13 - Only separately controlled display fixtures Installed in lobbies for the purpose of highlighting art and exhibits, that are independent of general area lighting, may be entered in this table. Note 14 - Lobby Art/Exhibit Display Allowance is automatically entered in LTG-INT-SPACE. Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2015 Washington State Ener Code Com Rance Forrns for Commercial Buildings includinq R2, R3, R4 over 3 stories and all R1 Revised Juty 2016 Project Title: Lenscrafters 0505 Southcenter Mall Date 8/28/2020 General Note - In Lobby areas, an additional wattage allowance is permitted for lighting installed specifically for the purpose of highlighting art and exhibits. Only Lobby areas with eligible display lighting rnay use this additional allowance. Proposed display lighting for each Lobby area may not exceed this allowance. Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage For Building Department Use Lobby Area NME 10 Lobby Description including (plan # & room #) Gross Interior Area in 1t2 Maximum Display Watts Allowed Per Area NOTE 11 Proposed Display Lighting Total Per Area NOTE 12 Total Lobby with Display Area Total Lobby ArVExhibit Display Allowance NOTE 14 Proposed Lobby Art/Exhibit Display Lighting Wattage "13 Lobby Area Location (plan #, room #) Fixture Description NOTE 6 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed Total Lobby Art/Exhibit Proposed Display Watts Interior Lighting Power Allowance • See footnotes on previous page Lighting, Motor, and Electrical Permit Checklist,Pg. 1 and all R1 LTG -CHK Revised Nov 2017 2015 Washington State Energy Code Compliance Forms tor Commercial Buildings including R2, R3, R4 over 3 stories Project Title: Lenscrafters 0505 Southcenter Mall Date 8/28/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS Yes C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken E002, E200 No C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters NA C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Yes C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specific application it serves E002, E200 Yes C405.2.21 C405.2.2.2 C405.2.3 Manual interior light reduction controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls E002, E200 Yes C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor, time switch or digital timer switch) for all lighting zones; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies E002 E200 Yes C4052.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50% -on, or serve a space eligible for automatic 100% -on per exception E200 E200 NA C405.2.12 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% Yes C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. E002, E200 YES C405.2.6 Digital timer switch Indicate digital timer switch control includes: manual on/off, time delay, audible and visual indication of impending time-out E200 NA C405.2.4.2 C405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. tt,; Indicate toplight daylight zone areas on plans, include sq. It.; For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) NA C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone NA C405.2.5 Additional controls - Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section Yes C405.2.5 • Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method E200 E002, E200 Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Dale 8/28/2020 The following information is necessary 10 check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA 0405.2.5 Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room NA C405.2.5 nem 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting C405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non -visual lighting applications, include sq, ft, area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Yes C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control E200 E200 E200 E002, E200 NA C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exterior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 Yes C405.2.5 (listed after C405.2.7) Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verity that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80 E200 E200 ADDITIONAL EFFICIENCY PACKAGE OPTION - ENHANCED DIGITAL LIGHTING CONTROLS NA C406.4 Enhanced digital lighting controls g 9 To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 8/28/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Yes 0405.4.1 0405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently E001 E200 Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per side) E200 NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). Interior Lighting Power Calculation - Indicate compliance path taken NA 0405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area; identify locations of building areas on plans Yes 0405.42.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage; identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY Yes 0406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 25% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method NA 0406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in interior fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option) EXTERIOR LIGHTING POWER & EFFICACY NA 0405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table 0405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA 0405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Lenscrafters 0505 Southcenter Mall Date 8/28/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING ALTERATIONS Yes C503.6 Interior and parking garage lighting fixture alterations Where z 50% o1 existing luminaires in interior space(s) or parking garage are replaced; indicate compliance path (building area or space -by -space method); include all new and existing -to - remain luminaires in compliance form (LTG -INT -BLD or LTG - INT -SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path Where < 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate total existing lighting wattage in each space prior to alteration; include all new and existing -to -remain luminaires in LTG -INT -SPACE form; indicate proposed total lighting wattage in alteration area does not exceed total existing lighting wattage prior to alteration NA C503.6 Exterior lighting fixture alterations Where z 50% o1 existing exterior lighting wattage is replaced; include all new and existing -to -remain luminaires in LTG -EXT form; indicate proposed total exterior lighting wattage does not exceed maximum allowed Where < 50% of existing exterior lighting wattage is replaced; indicate total existing lighting wattage prior to alteration; include all new and existing -to -remain luminaires in LTG -EXT form; indicate proposed total exterior lighting wattage does not exceed total existing wattage prior to alteration Yes C503.6 Interior lighting wiring alterations Where new wiring is installed to serve new interior luminaires and /or luminaires are relocated to a new circuit; indicate lighting controls are provided (as applicable) - manual (0405.2.3); occupancy sensor (0405.2.1); daylight responsive (C405.2.4); specific application (0405.2.5); exit signs (0405.3) NA 0503.6 Exterior lighting wiring alterations Where new wiring is installed to serve new exterior luminaires and /or luminaires are relocated to new circuit; indicate exterior lighting controls are provided (0405.2.7) Yes C503.6 Lighting panel alterations Where a new lighting panel is installed or an existing panel is moved (all new raceway and conductor wiring); indicate lighting controls are provided (as applicable) - same provisions as wiring alterations; time switch controls and manual light reduction controls (C405.2.2) Yes 0503.6 Interior space reconfiguration Where interior space(s) is reconfigured (permanently installed walls or ceiling -height partitions); indicate lighting controls are provided (as applicable) - same provisions as lighting panel alterations NA C504.2 Lighting repairs Identify existing luminaires being upgraded with bulb and / or ballast replacement; indicate fixture alteration does not increase existing fixture wattage NA 0505.1 Change of space use Identify spaces on plans where the building area type or space use type is being changed from one type to another per Tables 0405.4.2(1) or (2) Indicate compliance path (building area or space -by -space method); include all new and existing -to -remain luminaires in compliance form (LTG -INT -BLD or LTG -INT -SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path RECEPTACLES Yes C405.10 Controlled receptacles Identity all controlled and uncontrolled receptacles on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptacle zone is by occupant sensor or programmable time -of -day control E201 E002, E201 Lighting, Motor, and Electrical Permit Checklist, Pg. 5 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Lenscrafters 0505 Southcenter Mall Date 8/28/2020 The following information is necessary to check a permit application for compliance wilh the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION NA C405.6 Electrical transformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter Yes C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied M001 NA C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoccupied for a period of 15 minutes or more NA C405.9.2automatic Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; controls are configured to reduce operational speed to the minimum permitted when not in use NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided . . with a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (Cx) NA C408.3 Scope of electrical power and lighting systems commissioning Indicate that all electrical systems (receptacles, transformers, motors, vertical and horizontal transportation) for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; Where total building lighting load is > 20 kW, or where total lighting load of luminaires requiring daylight sensing and / or occupancy control > 10 kW, indicate that all automatic lighting control systems are required to be commissioned; or provide building lighting power calculation demonstrating eligibility for exception; NA C405.13Cx C408.1.1 C408.1.2 C408.1.4.2 C103.6 Commissioning requirements in construction documents Indicate Cx requirements in plans and specifications for all applicable electrical and lighting control systems per C408; Include general summary with at minimum Items 1 thru 4 of the plan per C408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (if required); Include in general summary that a Cx project report or Compliance Checklist (Figure C408.1,42) shall be completed by the Certified Cx Professional and provided to the owner prior to the final electrical inspection NA C408.3.1 Fu nctional performance testing criteria identity in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems PROJECT CLOSE OUT DOCUMENTATION Yes C103.6.3 Project close out documentation requirements Indicate in plans that project close out documentation is required including WSEC lighting compliance forms and calculations that document all interior and exterior lighting area and / or surface types, lighting power allowances and installed densities E001 If "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist Lighting Summary LTG -SUM liance Forms for Commercial Buildings includingR2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are wife - protected. Project Title: Lenscrafters 0505 Southcenter Mall Date 2/28/2020 Applicant Information. Provide contact information for individual oho can respond to inquiries about compliance form information provided. For Building Department Use Company Name: ---- 1 1-1 1 LI Company Address: 2441 Crown Pointe . :Jo : , 1 Applicant Name: Michael Rome - .._ Applicant Phone: 920-445-5007 Applicant Email: mromes@nextore.com Project Description 1:3 New Building 0 Addition Ed Alteration Q No Lighting Scope Include PROJ-SUM form (included in envelope forms workbook) Kith lighting compliance forms. Interior Lighting System Description 12 Interior Lighting Plans Included Interior lighting is based on LED light fixtures con sensors. lolle#EVIeNtbici...oditan CODE COMPLIANCE APPROVED . APR 23 2020 City of Tukwila Interior Lighting Power Allowance Method 0 Building Area Method BUILD NpAgnyISION Select method used in project. Interior Lighting Controls 121 All C405.2.1 - C405.2.8 Lighting Controls 0C405.2 Exception 5 Luminaire Level Lighting Controls (LLLC) ri Additional Efficiency Package Option C406.4 Enhanced Digital Lighting To comply Kith C406.4, no less than 90% of the total installed interior lighting poKer shall comply Kith required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in clKelling units comply Kith: 0 No Dwelling 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Units 0 C406.3 High Efficacy Lighting o R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies Kith WSEC Residential provisions in lieu of WSEC Commercial provisions. Exterior Lighting System Description 0 Exterior Lighting Plans Included There is no exterior lighting on this project. Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing -to -remain Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT For exterior lighting projects, include new + existing -to -remain Proposed Tradable and Proposed Non -Tradable Lighting Wattage Interior lighting Exterior lighting 0 0 0 0 interior lightingfi4tetivED -SPACE form. li exterior li ttOPTIJKW1 tables in LTG -EXT form. E A MAR 05 2020 (97 PERMIT CENTER Lighting Summary, cont. LTG -SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings includingR2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 2/28/2020 Change of Space Use Ga Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. Interior and Exterior Lighting Alterations Select all Lighting Pcmer and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting pouter compliance forms for the Mo retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting pcmer compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting : Parking garage Exterior lighting 50% or more of existing are replaced tr; IMI • Less than 50% of existing are replaced • • 0 Lamp and/or ballast replacement only — existing total wattage not increased 0 50% or more replaced - Total lighting politer of new + existing total LPA per Sections C405.4.2 and C405.5.2. Include new Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT Less than 50% replaced - Total lighting pouter of new + existing the total lighting pouter prior to alteration. Include new + existing Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or 50% threshold applies to number of luminaires for interior spaces installed viettage for exterior luminaires. 0 0 -to -remain fixtures shall comply vith + existing -to -remain fixtures in -SPACE or LTG -EXT form. -to -remain fixtures shall not exceed -to -remain fixtures in the Proposed LTG -EXT form. and parking garages, and total Lighting Controls Interior lighting New wiring installed to serve added : Parking garage Exterior lighting ' fixtures and/or fixtures relocated to r r; • II new circuit(s) New or moved lighting panel manual controls per C405.2.3, controls per C405.2.4 and application provide required controls per C405.2.7. as noted for New Wiring and automatic controls that apply to a new interior do not apply to reconfigured Interior space is reconfigured - • luminaires unchanged or relocated New wiring or circuit - For interior lighting, provide required occupancy sensor controls per C405.2.1, daylight responsive specific lighting controls per C405.2.5. For exterior lighting, New or moved panel - Provide all applicable lighting controls time svtitch controls per C405.2.2. Reconfigured interior space - Provide all required lighting space. Application specific lighting control provisions per C405.2.5 Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings ncluding R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 2/28/2020 Cakulation Area "°"9 0 New Construction 0 Addition - 0 Addition 0 Spaces where < 50% of 0 Spaces where 50% of 0 Spaces where the Use For Building Department Use LPA Calculation Type 0 Standard . Additional Efficiency Package Option C406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. User Note • 2 Maximum Allowed Lighting Wattage 32 Location (plan #, room 4) Space Type Ceiling Height N°7 2 Gross Interior Area in tt2 Allowed Watts per 112 Watts Allowed (watts/1t2 x area) 102, 104, 105, 108, 109, 113, 114, 115 Health care facility: Exam/treatment 8'-0" 645 1.330 858 111, 112 Restroom: all other 8'-0" 100 0.780 78 106 Office: Enclosed 8'-0" 149 0.890 133 103 Seating area, general 10'-0" 129 0.430 55 110 Corridor: all other 9'-0" 385 0.530 209 116 Health care facility: Medical supplies 9'-0" 99 0.590 29 101 Sales area 1 0 -6" 2448 1.270 3109 101 Sales area 12'-7" 254 1.270 323 Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 8 Total Area Retail Display 4159 LTG -INT -DISPLAY Allowed Watts Allowance from 1969 6758 Proposed Lighting Wattage"' Location (plan #, room #) TENO , Fixture Description 4, 56 Number of Fixtures Watts/ TE. NO Fixture 7 Watts Proposed 102 2x2 LED Lens (G2L & G2LE) 2 16 32 104, 105, 108, 109, 113, 114, 115 LED Downlight (DEM) 16 17 272 111, 112 2x2 LED Lens (G2LE) 2 16 32 106 2x2 LED Lens (G2L & G2LE) 2 16 32 103 LED Downlight (DBW) 6 17 102 110 2x2 LED Parabolic (A2L & A2LE) 4 15 64 110 LED Downlight (DBW) 6 17 102 116 LED Downlight (DBW) 3 17 51 101 LED Twin Adjustable Downlight - Emergency (K/12E) 21 40 840 101 LED Twin Adjustable Downlight (M1 & M3E) 12 39 408 Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 3000 4935 1 Interior Lighting Power Allowance COMPLIES WITH C406.3 Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category from drop dove menu. Note 2 • Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank, Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage trach/busway systems, enter the larger of the attached luminaire wattage or 50 watN/linpal tont nr pnrpr thp wattanp limit nf nermanpnt rnrrpnt limitinn ripwire Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby art/exhibit display fixtures in LTG -INT -DISPLAY form only. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and aross interior areas. Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2015 Washington State Enerqy Code Compliance Forms for Commercial Buildings includingR2, R3, R4 over 3 stories and ail R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 2/28/2020 General Note - In Sales areas, an increase in lighting poiner allowance is permitted for lighting installed specifically for the purpose of highlighting merchandise. Only Sales areas illuminated Wth eligible merchandise display lighting may be included in the Gross Interior Area under each Retail category. This lighting poKer allowance is the Maximum Retail Display Allowance OR the Total Retail Proposed Display Watts, whichever is less. Proposed retail display lighting wattage that exceeds this allowance is applied to general area lighting. Maximum Allowed Retail Display Lighting Wattage For Building Department Use User Note Watts Proposed Location (plan #, room #) Retail Sales Area Type NOTE 1 Gross Interior Area in ft2 Allowed Watts per ft2 NOTE 2 Watts Allowed (watts/f12 x area) NOTE 3 101 Retail 1: All unclassified retail display 2448 0 . 60 1469 Total Retail With Display Area Maximum 2448 Total Watts Base Allowance Allowance NOTE 4 Me= Retail Display Lighting Retail Display 500 1969 Proposed Retail Display Lighting Wattage "T" Retail Area Location (plan tt, room #) Fixture Description N°TE 6 Number of Fixtures Watts per ON TE 7 Fixture Watts Proposed Retail 1 101 220-0" Track, LED (El, E2, & E3) 1 3000 3000 RETAIL DISPLAY WATTAGE ALLOWANCE - PER LPA Proposed Retail Display Lighting Totals from LTG -INT -DISPLAY NOTE 8 Total Retail Proposed Display Watts NOTE 9 Retail Display Power Allowance 3000 1969 Retail 1 Retail 2 Retail 3 Retail 4 3000 Note 1 - Select retail sales areas from drop dowi menu. Only retail sales areas that comply Wth C405.4.2.2.1 may be entered in this table. Note 2 - Retail display lighting power allowances per C405.4.2.2.1, Equation 4-11. Note 3 - Unlit Message - Enter lighting fixture information for this retail sales area in Proposed Lighting Wattage table to generate Lighting Power Allowance, Note 4 - Maximum retail display wattage allowance as calculated per C405.4.2.2.1, Equation 4-11. Note 5 - Only separately controlled retail display fixtures that are independent of general area lighting per C405.4.2.2.1 may be entered in this table. Note 6 - For proposed Fixture Description, list ALL proposed display lighting fixtures. Indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaries Wth screwin lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For unItorro linhtinn ontPr tho iiterttiono of tho tronchormor For lino unItono trook/ho cuptomc ontor the lornpr nf the ottarhorl LFYV vvitayc 1194i4/ti9,cilial 14 lc vitillayc It IC Liai ,0,u,,1 Lli 44440 vvlicivG ticit.rvuu.vmay ytcI1, clam Inc I/O 0110,d IGU luminaire nettage or 50 netts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Total Retail Proposed Display Watts is automatically entered into the Proposed Fixture Wattage table in LTG-INT-SPACE. Note 9 - Retail display lighting poner allowance is the lesser of the Maximum Retail Display Allonence OR the Total Retail Proposed Display Watts. Retail display wattage allowance is automatically entered in the Maximum Allowed Lighting Wattage table in LTG-INT-SPACE. Note 10 - Enter a unique title for each lobby area in the project that has seperately controlled art/exhibit display lighting. A lobby area title (Column A) and the gross interior sf of the lobby area are are both required to generate the maximum display allonence. Note 11 - Lobby art and exhibitdisplay wattage allowance per Table C405.4.2(2), Footnote c 0.5 W/ft2, Note 12 - Proposed display lighting totals for each lobby area per information entered into Proposed Lobby Art/Display Lighting Wattage table. Note 13 - Only separately controlled display fixtures installed in lobbies for the purpose of highlighting art and exhibits, that are independent of general area lighting, may be entered in this table. Note 14 - Lobby Art/Exhibit Display Allowance is automatically entered in LTG-INT-SPACE. Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: Lenscrafters 0505 Southcenter Mall Date 2/28/2020 General Note - In Lobby areas, an additional mattage allomance is permitted for lighting installed specifically for the purpose of highlighting art and exhibits. Only Lobby areas Kith eligible display lighting may use this additional allowance. Proposed display lighting for each Lobby area may not exceed this allomance. Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage For Building Department Use Lobby Area N°TE 10NOTE Lobby Description including (plan # & room #) Gross Interior Area in ft2 Maximum Display Watts Allowed 11 Per Area Proposed Display Lighting Total NOTE 12 Per Area Total Lobby with Display Area Total Lobby Art/Exhibit Display Allowance NOTE 14 Proposed Lobby Art/Exhibit Display Lighting Wattage NOTE 13 Lobby Area Location (plan #, room #) Fixture Description NOTE 6 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed Total Lobby ArVExhibit Proposed Display Watts Interior Lighting Power Allowance * See footnotes on previous page Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 2/28/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS Yes C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken E002, E200 Luminaire level Indicate on plans all fixtures provided with LLLC in lieu of No C405.2 lighting controls (LLLC) C405.2 lighting controls; provide description of control capabilities and performance parameters NA 0405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception 0405.2.3 C405.2.1.1 Indicate on plans the method of manual lighting control (whether Yes 0405.2.2.2 Manual controls combined with occupancy sensor, automatic light reduction, E002, E200 0405.2.4 daylight responsive or specific application controls), location of 0405.2.5 manual control device and area or specific application it serves C405.2,2.1 Manual interior light Indicate on plans which method of manual 50% lighting load Yes 0405.2.2.2 reduction is provided, or whether lighting load is reduced via E002, E200 C405.2.3 reduction controls occupancy sensors or daylight responsive controls Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor, time switch or digital E002 Yes 0405.2.2 Method of automatic shut-off control timer switch) for all lighting zones; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies E200 Indicate on plans the spaces served by occupancy sensors; E200 Yes C405.2.1 Occupancy sensor Indicate whether occupancy sensor controls are configured to 0405.2.1.1 controls be manual-on, automatic 50%-on, or serve a space eligible for automatic 100%-on per exception E200 Occupancy sensor Indicate aisleways and open areas in warehouse spaces NA 0405.2.1.2 controls - warehouses provided with occupancy sensor controls that reduce lighting power by 50% Yes 0405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. E002, E200 YES 0405.2.6 Digital timer switch Indicate digital timer switch control includes: manual on/off, time delay, audible and visual indication of impending time-out E200 Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; 0405.2.4.2 Daylight zones - Indicate toplight daylight zone areas on plans, include sq. ft.; • NA 0405.2.4.3 Sidelight and toplight For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that NA 0405.2.4 Daylight responsive controls apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone Additional controls Identify spaces and lighting fixtures on plans that require NA 0405.2.5 Specific application lighting controls specific application lighting controls per this section Indicate on plans that display and accent lighting, and display Yes 0405.2.5 - Items 1 &2 Display and accent lighting case lighting are controlled independently from both general area lighting and other lighting applications within the same space; E200 Indicate manual and automatic lighting control method E002, E200 Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 2/28/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA C405.2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room NA C405.2.5 Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting 0405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA 0405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Yes C405.2.5 - Item 7 Means of egress lighting 9 Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting; If total egress lighting power densityisgreater than 0.02 W/sq. 9 9 9 q• ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control E200 E200 E200 E002, E200 NA C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exterior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA 0405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per 0405.5.2 Yes 0405.2.5 (listed after C405.2.7) Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% E200 E200 ADDITIONAL EFFICIENCY PACKAGE OPTION - ENHANCED DIGITAL LIGHTING CONTROLS NA C406.4 Enhanced digital lighting controls 9 9 To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) Lighting, 2015 Washington Motor, and Electrical Permit Checklist, Pg. 3 LTG -CHK State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Lenscrafters 0505 Southcenter Mall Date 2/28/2020 The following information is necessary to check a permit application tor compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Yes C405.4.1 C405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently E001 E200 Yes 0405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per side) E200 NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). Interior Lighting Power Calculation. Indicate compliance path taken NA C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area; identify locations of building areas on plans Yes C405,42.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage; identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable ADDITIONAL EFFICIENCY PACKAGE OPTION - REDUCED INTERIOR LIGHTING POWER DENSITY Yes 0406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 25% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method NA 0406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in interior fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option) EXTERIOR LIGHTING POWER & EFFICACY NA C405,5,2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5,1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed Lighting, 2015 Washington Motor, and Electrical Permit Checklist, Pg. 4 LTG -CHK State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Lenscrafters 0505 Southcenter Mall Date 2/28/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING ALTERATIONS Yes C503.6 Interior and parking garage lighting fixture alterations Where a 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate compliance path (building area or space -by -space method); include all new and existing -to - remain luminaires in compliance form (LTG -INT -BLD or LTG - INT -SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path Where < 50% of existing luminaires in interior space(s) or parking garage are replaced; indicate total existing lighting wattage in each space prior to alteration; include all new and existing -to -remain luminaires in LTG -INT -SPACE form; indicate proposed total lighting wattage in alteration area does not exceed total existing lighting wattage prior to alteration NA C503.6 Exterior lighting fixture alterations Where a 50% of existing exterior lighting wattage is replaced; include all new and existing -to -remain luminaires in LTG -EXT form; indicate proposed total exterior lighting wattage does not exceed maximum allowed Where < 50% of existing exterior lighting wattage is replaced; indicate total existing lighting wattage prior to alteration; include all new and existing -to -remain luminaires in LTG -EXT form; indicate proposed total exterior lighting wattage does not exceed total existing wattage prior to alteration Yes 0503.6 Interior lighting wiring alterations Where new wiring is installed to serve new interior luminaires and /or luminaires are relocated to a new circuit; indicate lighting controls are provided (as applicable) - manual (0405.2.3); occupancy sensor (0405.2.1); daylight responsive (C405.2.4); specific application (C405.2.5); exit signs (C405.3) NA 0503.6 Exterior lighting wiring alterations Where new wiring is installed to serve new exterior luminaires and /or luminaires are relocated to new circuit; indicate exterior lighting controls are provided (C405.2.7) Yes 0503.6 Lighting panel alterations Where a new lighting panel is installed or an existing panel is moved (all new raceway and conductor wiring); indicate lighting controls are provided (as applicable) - same provisions as wiring alterations; time switch controls and manual light reduction controls (0405,2.2) Yes C503.6 Interior space reconfiguration Where interior space(s) is reconfigured (permanently installed walls or ceiling -height partitions); indicate lighting controls are provided (as applicable) - same provisions as lighting panel alterations NA C504.2 Lighting repairs Identify existing luminaires being upgraded with bulb and / or ballast replacement; indicate fixture alteration does not increase existing fixture wattage NA 0505.1 Change of space use Identify spaces on plans where the building area type or space use type is being changed from one type to another per Tables 0405.4,2(1) or (2) Indicate compliance path (building area or space -by -space method); include all new and existing -to -remain luminaires in compliance form (LTG -INT -BLD or LTG -INT -SPACE); indicate proposed lighting wattage does not exceed maximum allowed per compliance path RECEPTACLES Yes 0405.10 Controlled receptacles Identify all controlled and uncontrolled receptacles on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptacle zone is by occupant sensor or programmable time -of -day control E201 E002, E201 Lighting, 2015 Washington Motor, and Electrical Permit Checklist, Pg. 5 LTG -CHK State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Lenscrafters 0505 Southcenter Mall Date 2/28/2020 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION NA C405.6 Electrical transformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA 0405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter Yes 0405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied M001 NA 0405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is slopped and unoccupied for a period of 15 minutes or more NA 0405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA 844; automatic controls are configured to reduce operational speed to the minimum permitted when not in use NA 0405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (Cx) NA C408.3 Scope of electrical power and lighting commissioning Indicate that all electrical systems (receptacles, transformers, motors, vertical and horizontal transportation) for which the WSEC requires control functions and / or configuration to perform specific functions are required to be commissioned; Where total buildingsystems lighting load is > 20 kW, or where total lighting load of luminaires requiring daylight sensing and / or occupancy control > 10 kW, indicate that all automatic lighting control systems are required to be commissioned; or provide building lighting power calculation demonstrating eligibility for exception; NA C405.13Cx 0408.1.1 0408.1.2 0408.1.4.2 0103.6 Commissioning requirements in construction documents Indicate Cx requirements in plans and specifications for all applicable electrical and lighting control systems per C408; Include general summary with at minimum Items 1 thru 4 of the plan per 0408.1.2 including: narrative description of activities, responsibilities of the Cx team, schedule of activities including verification of project close out documentation per C103.6, and conflict of interest plan (it required); Include in general summary that a Cx project report or Compliance Checklist (Figure 0408.1.4.2) shall be completed by the Certified Cx Professional and provided to the owner prior to the final electrical inspection NA 0408.3.1 Functional performance testing criteria Identify in plans and specifications the intended operation of all equipment and controls during all modes of operation, including interfacing between new and existing -to -remain systems PROJECT CLOSE OUT DOCUMENTATION Yes 0103.6.3 Project close out documentation requirements Indicate in plans that project close out documentation is required including WSEC lighting compliance forms and calculations that document all interior and exterior lighting area and / or surface types, lighting power allowances and installed densities E001 If "no" is selected for any question, provide explanation: 4 End of Lighting, Motor & Transformer Permit Documents Checklist PLAINKIRFIRMIYING SLIP PERMIT NUMBER: EL19-1067 DATE: 9J22/20 PROJECT NAME: LENSCRAFTERS SITE ADDRESS: 416 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 2 after Permit Issued DEPARTMENTS: 17 Building Division /1111*-4d7c) Public Works Fire Prevention Structural Planning Division 111 Permit Coordinator n PRELIMINARY REVIEW: Not Applicable L. (no approval/review required) REVIEWER'S INITIALS: DATE: 9/22120 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved DUE DATE: 11117120 Approved with Conditions Fire Fees Apply Corrections Required ri Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire J Ping El PW D Staff Initials: 12/18/2013 o - PERMIT MORD COPY() PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: ELi9lo63 DATE: 03/05/2020 PROJECT NAME: LENSCRAFTERS SITE ADDRESS: 416 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # X Revision # 1 before Permit Issued Revision # after Permit Issued DEPARTMENTS: 3 AT \9,0 Building Division 111 Fire Prevention Public Works Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 03/10/2020 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 04/21/2020 Fire Fees Apply REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping Li PW El Staff Initials: 12/18/2013 Ci3ERM!T COOP.D COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL19-1067 DATE: 12/31/2019 PROJECT NAME: LENSCRAFTERS SITE ADDRESS: 416 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Budding Public Works 111111111111111111111111•1111111111111111111111111111110. PRELIMINARY REVIEW: Not Applicable r (no approval/review required) Fire Prevention Planning Division Structural Permit Coordinator r 1 REVIEWER'S INITIALS: DAlE: 12/31/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 1/28/2020 Approved with Conditions Ti Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping D PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Ck (IRN Plan Check/Permit Number: EL 1 - 0G1 O Response to Incomplete Letter # O Response to Correction Letter # O Revision #31-4 after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner Deferred Submittal # RECEIVED CITY OF TUKWILA SEP 22 2020 PERMIT CENTER Project Name: L_EriSCRACTeVS e, SCr•fri-XeNirer2- Project Address: 416 so.truc_eryrea. mALL Contact Person: -.111Y\ 5 -CA -18-41c. Phone Number: Q51- 1(45.- ,(J(.Q Summary of Revision: SCE IS•fr act-te.NO aeit5IGH U-Cnris M.Orn GriGifiEtn_ Sheet Number(s): Eoal Ea02.1E003 Eau+, El ,Ezcx3 eici, €262. "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: O Entered in TRAKiT on WAPermit cauterkTemplutes \FonseaRrvisima Submittal Form.dac Revised: August 20IS Date: 3 I ZC) City of Tukwila REVISION SUBMITTAL Department of Community Develop en 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwi I aW A . gov RECEIVED MAR 05 2O Community Development Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: Et_ % to61 0 Response to Incomplete Letter # El Response to Correction Letter # Revision # 2- after Permit is Issued 0 Revision requested by a City Building Inspector or Plans Examiner El Deferred Submittal # Project Name: 1-.E.riScRAWASS15 Project Address: um swn-icertren. Contact Person: -Ti m ci€r4. Summary of Revision: SAcmciAe0 OhNts tort ggcs,.511r4 Phone Number: ci 52 .13445% 60+3 Sheet Namber(s); te002 ocr3, 00 dr ,€00s. zoo ez(3‘,E.2(52.- "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: Entered in TRAKiT on 3-5 2,0-0 W:Wcrrnit Center\ Templatefforma\Revis ion Submittal Forra.doc Revised: August 2015 Revision #3'MEP, O605Sumthowniar 08-14-20 MECHANICAL Sheet M0O1: Revised detail F. Revised note 2 in the RTU schedule. Sheet M002: Removed the water source heat pump area of the specs. Sheet M200: Added note 21. Added the air baiance note to the plan. Revised the diffuser schedule. Revised the sales area and some BOH spaces to use siot diffusers. ^' LE —D FO OOMPLIANC WITH NFPA 70 - NEC ELECTRICAL Sheet E001: Revised various fixtures in the Iight fixture schedule. Sheet E002: Revised various details, Added an additional switch to the switchbank detail. Sheet E003: Revised various details. Sheet E004: Revised data at patch panels PPA, PPB, PPC, and PPD. Revised the communications riser. Sheet E200: Revised notes 5 thru 7. Revised Iighting on the sales floor and some BOH spaces. Sheet E201: Removed note 28. Added fire alarm deferred submittal note. Revised sales floor outlets and various outlets in the BOH space. Sheet E202: Revised phasing ptans and notes. PLUMBING Sheet P002: Revised isometrics for plan updates. Sheet P200: Revised misc ptumbing fixture Iocations and adjusted piping. FIRE PROTECTION Sheet FP200: Added fire protection deferred submittal note. OCT 27 2010 City of Tukwila UILDING DIVISION RECEIVED CITY OF TUKW SEP22 �°., °°��v�v PERM,[CEWE A NO 1 47 Revision #4 - MEP, 0505 Southcenter, 08-28-20 MECHANICAL Sheet M001: Revised thermostat schedue, Sheet M200: Revised note 1 in the diffuser schedule. Sheet K8P2O1: Revised phasing p!ans arid notes. ELECTRICAL Sheet E003: Revised information in misc. details. Sheet E004: Revised data at patch panel PPD, Sheet E100: Revised note 16. Revised storefront column receptacle to be removed. Sheet E200: Revised swtch Iocations in various BOH rooms. Revised storefront Iighting. Sheet E201: Revised data outlets and receptacles in the lab. Shifted an outlet ocation in exam. Sheet E202: Revised phasing ptans and notes. PLUMBING Sheet P002: Revised isometrics for plan updates. Sheet P200: Revised misc plumbing fixture Iocations and adjusted piping, FIRE PROTECTION Sheet P002: Updated iso's to match floor ptan revisions. REVISION NO, a- 10‘ 7 BEV Revision #2 - MEP, 0505 Southcenter, 03-2-20 MECHANICAL Sheet MOO1: Revised the sales floor heat calcs. Revised the RTU Schedule, Added the dodicated outdoor air system to schedule to the plan. Revised the thermostat detail. Sheet M100: Revised note 4. Added note 9. Added HVAC control diagram to the plan. Added the duct heater to the schedule. Sheet M200: Revised notes 11, 13 and 14. Added notes 15 to 22 to the plan. Added AHU, intake an relief detalis to the drawing. Revised the diffuser schedufe. Added the ERV and various ductwork changes to the plan. SheetK4P201 New sheet added to the set. ELECTRICAL Sheet E001: Revised Iight fixture schedule. Sheet E002: Revised details. Revised contactors in detail E001. Sheet E003: Revised details. Sheet E004: Revised patch panels PPA and PPD. Sheet E005: Revised details. Revised panel B. Sheet E200: Revised the size 01 the current limiters on the track circuits, Revised the track sizes and removed gaps in some track sections. CITY OF Sheet E201: Revised power to the ERV arid duct heater. RECEIVED ---~~°"~°A MAR /�� ���� - � �,"«m �'� � ��� 0����� �� Q0� 0���� � EL1 � �-�=� � ° w�RM&Q����/V � u����~~���'~~Eww Revised thwall fixture on the sales floorremoved LED wafls and replaced with Iightboxes at the storefront. Revised the quantity at data at the reception desk. Revised the power and data at the cashwrap. Sheet E202: New sheet added to the set. PLUMBING Sheet P001: Revised the piping insulation specs. Added recirculation pump to the plumbing schedule. Added minimum pipe insulation schedule to the plan. Sheet P002: Revised the plumbing supply isometric Sheet P200: Added mop sink genera note. Revised note 1 in the plumbing supply notes. Added notes 7, 8 and 9 in the plumbing supply notes. Added recirc pump piping installation detail. Added maximum piping water volume chart to the plan. Revised piping supply plan. FIRE PROTECTION Sheet FP200: Revised the fire protection legend. ' D C ELECTRIC INC Page 1 of 2 LAI regional offices are closed to public visits until further notice. Offices can still help you by phone from 8 a.m. to 5 p.m. weekdays (except state holidays). Use the phone number for your closest regional office (htlps://lnimaxioviagencv/contact/#office-locations), or you can call the Office of Information and Assistance at 360-902-5800. 0 tabor & Industries (http,$:,/,',1 D C ELECTRIC INC Owner or tradesperson Principals CASTOE, DANNY, PRESIDENT CASTOE, HEATHER, SECRETARY CASTOE, HEATHER, AGENT CASTOE, HEATHER, PRESIDENT (End: 07/3012012) Doing business as D C ELECTRIC INC WA UBI No, 602 848 189 23117 63RD AVE W MOUNTLAKE TERRACE, WA 98043 206-940-4963 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending an trade) and any past violations, Electrical Contractor Active Meets current requirements. License specialties GENERAL License no. DCELEEI924ND Effective — expiration 08/04/2008— 08/18/2022 Designated administrator Active CASTOE, DANNY A Meets current requirements. License type License no. Electrical Administrator CASTOD*98808 Bond AMERICAN CONTRACTORS INDEM CO $4,000.00 Bond account no. 100052096 Received by L&I Effective date 08/04/2008 08/01/2008 7/3) Ai littric•//epoHrf.1 n anvivpri-Ranetail acrw9I TRI=6117 R4R 1 R9X,T JC=DCF,T ,F.F1974ND&S AW= R/27/2020 LIGHT FIXTURE SCHEDULE - LENSCRAFTERS INLINE ALL NEW FIXTURES ARE OWNER SUP PLIED, EC INSTALLED LAMP FIXTURE NOTES TSG 1 N NU A E L B R I I C L R L A2L 20W RECESSED 2X2 LED PANEL ENVISION LED-BPL-2X2-PC-CCT-HL-20-30K WHITE 120V 20W LED CHIP, 0-I01/ DIMMING 1 20 20W RECESSED 2X2 LED PANEL W/1320LUM RESTICKERED (20W) INCANDESCENT CAN WITH RL38-ICESA (HOUSING). CTR3802-P-W (BLACK L 2 1 1 G2L NOT USED G2LE NOT USED MI 2 LAMP, WITH BLACK TRIM BLACK INTERIOR, LED DOWNLIGHT, 15 DEGREE OPTIC VIABIZZUNO MINITRAFFIC- M1 BLACK 120V 16.SW, 3000K, 92 CRI 2 33.6 M2E NOT USED M3 2 LAMP, WITH BLACK TRIM BLACK INTERIOR, LED DOWNLIGHT, 31 DEGREE OPTIC VIABIZZUNO MINITRAFFIC-M3 BLACK 120V 16.8W, 3000K, 92 CRI 2 33.6 El BLACK TRACK HEAD, 15 DEGREE OPTICS VIABIZZUNO ECONOTRACK - El BLACK 120V 20.5W, 3000K, 92 CRI 1 20.5 E2 BLACK TRACK HEAD, 24 DEGREE OPTICS VIABIZZUNO ECONOTRACK - E2 BLACK 120V 20.5W, 3000K, 92 CRI 1 20.5 E3 BLACK TRACK HEAD, 31 DEGREE OPTICS VIABIZZUNO ECONOTRACK - E3 BLACK 120V 20.5W, 3000K, 92 CRI 1 20.5 TN/ TRACK, BLACK FINISH, FIELD CUT TO MATCH SIZE ON PLANS, PROVIDE END FEEDS AND CONNECTORS AS REQUIRED VIABIZZUNO ECONOTRACK -T1, T2, T3, T4, T# BLACK 120V N/A X1RW WHITE, SEMI -RECESSED EXTRUDED A WMINUM LED EDGE UT EXIT SIGN, RED LETTERS, CEILING MOUNTED UGHTALARMS SPLEDWRCD (WHITE) WHITE 120/277 LED W/UNIT 3 CLP-i#A TRACK CURRENT LIMITER PANEL THE "Tr INDICATES THE AMPACITY OF THE CURRENT LINTER. SEE PLANS. ACUITY/SILVER BULLET 3 STANDARD 120V N/A r _ _ - _ _ _ _ - _ _ _ _ .'-". J241W-1gni11-(5n( - - A 1 -1 (1)-SM P2 _ --�� 104 V T I - I CONTROLS COS CURNG OCCUPANCY SENSOR SENSORSWITCH CM-PDT-10 WHITE OS WALLOCCUPANCY SENSOR LUTRON MS-A102-WH WHITE OSD WALLOCCUPANCY SENSOR/DIMMER LUTRON MS-2101 WHITE D SLIDE DIMMER GREENGATE WBSD-0105LD-W WHITE NOTES: 1. SEM RECESSED EDGE LIT EXIT SIGN WITH RED LETTERS FOR CEILING MOUNTING. WHITE FINISH FOR CANOPY WHERE EXPOSED TO VIEW. RED LED INCLUDED. 2. POWERS FIXTURES IN THE EVENT OF A POWER FAILURE. SEE WIRING DETAIL. GENERAL' SUPPLIER TO PROVIDE WALL OCCUPANCY SENSORS, DIMMERS, AND/OR COMBINATION SENSORS/DIMMERS. SEE PLANS FOR EXACT QUANTITY. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GENERAL CONTRACTORS COST. BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. ELECTRICAL SYMBOLS (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) HOMERUN TO PANEL AND CIRCUIT INDICATED PANEL CIRCUIT - - - - INFLOORAJNDERFLOOR CONDUIT/WIRE O JUNCTION BOX et oc •ci 0 no DUPLEX RECEPTACLE -125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18' AFF UNLESS OTHERWMSE NOTED: ' 2' INDICATES CIRCUIT NUMBER ' E' EXISTING TO REMAIN ' WP" INDICATES WEATHERPROOF COVER ▪ DEDICATED CIRCUIT ' GFI' INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE 'R' INDICATES RECESSED DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18' AFF UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. 'CLG' INDICATES MOUNTED IN CEILING COMBINATION DUPLEX RECEPTACLE AND VOICE/DATA OUTLET MOUNTED IN FLOOR BOX. DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. COMMUNICATIONS FLOOR BOX SWITCH - SINGLE POLE TOGGLE TYPE - 120/277 VOLT, 1-HP RATED, 20 AMPERE, MOUNTED AT 48" AFF UNLESS OTHERWISE NOTED: "3- INDICATES THREE WAY SWITCH "4' INDICATES FOUR WAY SWITCH "C' INDICATES SWITCH MOUNTED 8' ABOVE COUNTER 'OS" INDICATES OCCUPANCY SENSOR SWITCH 'D' INDICATES DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR "MS" SWITCH USED AS A MASTER OVER OTHER SWITCHES IN THE ROOM CEILING MOUNTED OCCUPANT SENSOR LIGHT FIXTURE: 'AD" INDICATES FIXTURE TYPE "a' INDICATES SWITCH CONTROL. REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION. TL TRACK AND TRACK MOUNTED LIGHT FIXTURE (DESIGNATIONS VARY - #T-S SEE PLANS) OD RECESSED DOWNLIGHT. DESIGNATIONS VARY - SEE PLANS. ® ILLUMINATED 'EXIT" SIGN LIGHTING FIXTURE. CEILING MOUNTED OR WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. V 0 WIFI MOTION DETECTOR LIGHTING TIME CLOCK DATA OUTLET: MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4' CONDUIT TO ABOVE THE ACCESSIBLE CEILING. SEE ELEVATIONS FOR HEIGHTS. SWITCHED WIRING BRANCH CIRCUIT WIRING HOMERUN MOTOR DOOR BELL EXTERIOR PUSH BUTTON DOOR BELL TRANSFORMER AND SIGNAL SPEAKER SECURITY CAMERA FIRE ALARM DEVICES ARE ONLY SHOWN FOR PREFERENTIAL LOCATION. FINAL LOCATIONS AND QUANTITIES SHALL BE DETERMINED BY LL AND FIRE ALARM ENGINEER- VERIFY PRIOR TO ROUGH IN. • FIRE ALARM MANUAL PULL STATION MOUNTED AT 48' AFF. Eli FIRE ALARM AUDIO/VISUAL ALARM SIGNAL WALL MOUNTED AT 80' AFF. ❑V FIRE ALARM VISUAL ONLY ALARM SIGNAL WALL MOUNTED AT 80' AFF. �V CLG FIRE ALARM VISUAL ONLY ALARM SIGNAL CEILING MOUNTED IC CLG FIRE ALARM AUDIO/VISUAL ALARM SIGNAL CEILING MOUNTED O FIRE ALARM SMOKE DETECTOR FIRE ALARM SMOKE DETECTOR - DUCT MOUNTED DIVISION 16000 - ELECTRICAL PART I -GENERAL A. GENERAL CONDITIONS, CODES & STANDARDS 1. ALL WORK SHOWN ON THE ELECTRICAL DOCUMENTS 15 TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. 2. ALL WORK TO MEET APPLICABLE CODES AS LOCALLY ENFORCED. NO WORK ON THE DRAWINGS IS TO BE INSTALLED WHERE IT CONFLICTS WITH LOCAL CODE ENFORCEMENT. COORDINATE WITH THE LOCAL INSPECTOR PRIOR TO INSTALLATION. 3. ELECTRICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL EQUIPMENT AND TOOLS NECESSARY TO COMPLETE THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN. S. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND RELATED WIRING SHALL BE PROVIDED TO OSHA REQUIREMENTS FOR THE USE OF ALL TRADES DURING CONSTRUCTION. B. SCOPE OF WORK 1. ONLY MAJOR EQUIPMENT I5 SHOWN ON THE DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL BID AND CONSTRUCT A COMPLETE AND OPERATIONAL SYSTEM. MISCELLANEOUS EQUIPMENT REQUIRED TO COMPLETE THE WORK IS IN THE ELECTRICAL CONTRACTOR'S SCOPE - ASSUME NO WORK OR EQUIPMENT IS PROVIDED BY OTHERS UNLESS STATED AS SUCH. 2. DURING BIDDING: 2.1. VERIFY THE EXISTING CONDITIONS AND COMPENSATE FOR ANY VARIATIONS IN THE SCOPE AS A RESULT. 2.3. WHERE THERE IS A CONFLICT THAT CANNOT BE RESOLVED BY THE GENERAL CONTRACTOR, ADVISE ENGINEER PROMPTLY FOR A RESOLUTION. DO NOT PROVIDE WORK WHEN THERE IS UNCERTAINTY ON WHAT WORK IS TO BE PERFORMED. 3. AS PART OF THE BIDDING PROCESS, REPORT TO THE TENANT ANY ERRORS OR UNCLEAR DIRECTIONS THAT YOU HAVE IDENTIFIED. C. DOCUMENTS 1. SUBSTITUTIONS 1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND MATERIALS EQUIVALENT TO THOSE INDICATED. 2. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS D. CONSTRUCTION COORDINATION 1. DURING BIDDING YOU VISITED THE SITE. WORK WITH THE GENERAL CONTRACTOR TO COORDINATE ANY CONFLICTS WITH EXISTING CONDITIONS. THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE TENANT. 2. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE DAMAGE. PART 2-PRODUCTS A WIRING DEVICES 1. DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE,NEMA 5-20R RATED FOR 20 AMPS,12 5 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. 1.1. SPECIFICATION GRADE DUPLEX RECEPTACLE SHALL BE HUBBELL #5362 SERIES OR APPROVED EQUAL HEAVY DUTY, WHITE. 1.3. GROUND FAULT CIRCUIT INTERRUPTER (GF) DUPLEX RECEPTACLES SHALL BE PROVIDED WHERE INDICATED. 2. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, RATED FOR 20 AMPS, 120/277 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE PROVIDED WHERE INDICATED. 2.1. SINGLE POLE SWITCHES SHALL BE LEVITON #1221 SERIES OR APPROVED EQUAL SILENT ACTUATING, 20-AMP, 120/277V, WHITE. 2.2. THREE POLE SWITCHES SHALL BE LEVITON #1223 SERIES OR APPROVED EQUAL SILENT ACTUATING, 20-AMP, 120/277V, WHITE. 3. DIMMERS SHALL BE LEVITON SUDING DIMMER SWITCH, OF A RATING, VOLTAGE AND WATTAGE SUITABLE FOR LOAD SERVED. COLORS OF DEVICES AND COVERPLATES SHALL WHITE. 4. COMBINATION WALL DIMMER/OCCUPANT SENSOR SHALL BE LUTRON MAESTRO 0-10V DIMMER WITH INTEGRAL PASSIVE INFRARED OCCUPANT SENSING, AVAILABLE IN 1-WAY OR 3-WAY CONFIGURATIONS. COLOR TO BE WHITE. VERIFY LOAD SERVED IS COMPATIBLE PRIOR TO ORDERING. 5. WIRING DEVICES SHALL BE SPECIFICATION GRADE. 6. COVERPLATES FOR POWER, DATA & TELEPHONE SHALL BE LEVITON OR APPROVED EQUAL, WHITE, PLASTIC. 7. LIGHTING CONTRACTORS SHALL BE IN NEMA 1 ENCLOSURE, NORMALLY OPEN ELECTRICALLY HELD, 120V, COIL, 20A. REFER TO PLANS FOR NUMBER OF POLES. B. LIGHTING AND RECEPTACLE LOAD CENTERS (PANELS) 1. BRANCH CIRCUIT LOAD CENTERS SHALL BE DEAD FRONT TYPE, WITH MAIN LUGS OR MAIN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS NOTED AND AN EQUIPMENT GROUND BAR. ALL IN A FLUSH MOUNTED SHEET STEEL ENCLOSURE. MINIMUM SHORT CIRCUIT CAPACITY SHALL BE 10,000 AMPS SYMMETRICAL FOR 120/208V, AND 14,000 AMPS SYMMETRICAL FOR 277/48DV APPLICATION UNLESS NOTED OTHERWISE. LOAD CENTERS MUST BE SELECTED TO FIT IN A STANDARD STUD WALL. 2. LOAD CENTERS SHALL BE AS MANUFACTURED BY SQUARED, GENERAL ELECTRIC, ITE/SIEMENS AND WESTINGHOUSE/CUTLER HAMMER. C. FIXTURES AND LAMPS 1. ALL FIXTURES AND LAMPS ARE FURNISHED BY TENANT, NSTALLED BY ELECTRICAL CONTRACTOR.. D. FIRE ALARM SYSTEM 1. ALL WORK RELATED TO THE FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. OWNERS REPRESENTATIVE WILL PROVIDE SPECIFICS ON THE SYSTEM. PART 3 - EXECUTION A. GENERAL MISCELLANEOUS 1. ALL CONDUIT RUN IN FINISHED AREAS SHALL BE CONCEALED. 2. 2. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH BRANCH CIRCUIT IDENTIFICATION FOR BRANCH CIRCUIT PANELBOARDS. PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH NEC 110.16. 3. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR NIGHT LIGHITNG, EMERGENCY AND SIMILAR CIRCUITS. 4. ALL FLUSH MOUNTED ;LOADCENTERS SHALL HAVE (3) 3/4' EMPTY CONDUITS INSTALLED TO ABOVE ACCESSIBLE CEILING FOR FUTURE USE. 5. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, ETC. SHALL BE SUBJECT TO REASONABLE CHANGES N LOCATION UP TO THE TIME OF ROUGHING -IN, AT NO ADDITIONAL COST TO THE TENANT. B. GROUNDING 1. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING CONDUCTOR INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS AND SUPPLEMENTAL AS REQUIRED TO MEET CODE (SUCH AS ARTICLE 517). C. TESTS 1. TEST FOR GROUNDS, SHORT CIRCUITS, AND PROPER FUNCTION OF ALL EQUIPMENT AFTER INSTALLATION IS COMPLETE. FAULTS IN THE INSTALLATION SHALL BE CORRECTED AT NO COST TO THE TENANT. D. DEMOLITION 1. DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT, F APPLICABLE, SHALL BE PART OF THE ELECTRICAL WORK AS INDICATED ON THE DRAWINGS. GENERAL NOTES A. IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE EC. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. B. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. C. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS, IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. D. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. E. LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0' TO 250'-Cr IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM, F. E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY NEXTORE. E.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, E.C. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH NEXTORE. G. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. H. E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. I. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS FOLLOWS, UNLESS NOTED.. OTHERWISE ON PLAN: SWITCHES-48", ELECTRICAL/TELEPHONE/DATA OUTLETS-18", TOP OF PANELBOARDS-6'-6", TIMECLOCKS-5'-0". FOR ALL LENS PROCESSING ROOM OUTLET MOUNTING HEIGHTS SEE EQUIPMENT WIRING SCHEDULE J. FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIOR LIGHTING FIXTURES, AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 12'-0". K. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING "AS BUILT' DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO NEXTORE PROJECT MANAGER. L. IT IS THE EC.'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM (WITH -IN 10%). M. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND ORDINANCES. N. ALL OUTLETS IN THE LENS PROCESSING ROOM ARE TO BE LABELED WITH PANEL AND CIRCUIT NUMBER. O. THE E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. P. SEE DATA RISER ON THIS SHEET FOR ADDITIONAL INFORMATION. Q PROVIDE POWER TELEPHONE AND DATA CONDUIT WITHIN FLOOR, BETWEEN FIXTURE AND NEAREST WALL AS INDICATED ON PLANS. METHOD OF CORE DRILLING SHALL BE PER BUILDING REQUIREMENTS. ALL CORE DRILL REQUIREMENTS SHALL BE VERIFIED WITH LANDLORD. CONTRACTOR SHALL SIZE CONDUIT PER NEC. PROVIDE FOR X-RAY OF FLOOR WHERE REQUIRED BY THE LANDLORD. CLARIFYE CABLING & NETWORKING QA CHECKLIST To be completed by Project Manager on Monday the week of the C(ARIFYE Installation tang of the tasks or labels are not completed correctly, escalate to the on -site Fleet Renewal Manager Immediately. $', �+• ,fx� .all 'a sap$ �FYLi f. , -.. ., r. v! ., i.> -..v4 .. s._ - it Confirm the modem is extended intothe DOC IX the Internet service does not have a modem and B is 'last a jack, confirm the • Is patched over to the DOC) k!' ,aRwF- Confirm the modem is labeled as the "CURIFYE Modem" Confirm the DDC has a 48 port Patch Panel Installed Confirm there is a switch in the DOC labeled as 'Doctor Switch- Confirm Cisco Meraki wireless router mounted to the wall C from the floor on the centerline above the DOC Confirm the Cisco Merakl wireless router b labeled as the "CWIIFYE Router Confine there is a 6 port data jack 5'10" from the floor and 8"from the oenteriine of the DOC Confirm duce Is a power outlet 5'10" from the floor and It" from the centerline of the DX Confirm Cisco Merakl wireless router Is online with a solid white status light Tg"`x'�",� Confirm the Recessed Entertainment Box Is installed 6'r from the floor and 3' 4" from the ri: ht hand wall when facn: the bon Confirm the cable runs for the wireless access polls are to the correct locations and labeled on the cells t Sn y • :N' , - a+... ;ter 11:01. CO a d1. ralM# .ae:ve a &,nI NOTE:.- %tbS t1I Si t"°Ov= aw are IS RAC may AMOR aadrtta. '1e.. JUIILfi Version: 3/23/201B Date Completed: Completed By: V X 'tF. "7" II r{.::i.+: r` Pretest1 M. Sif. thl. , 4, dt DOC Patch Panty S.; fan -•+.es .. A. S.,,s Ws 2 , - PIA -PUB don i;F 4 PIA-P1B xAvlta s pa1a,, .5a ..fB0.:-;, Pretest 1 DOC Patch Panel 2 PIC-P1D P1CP1D Pretest I DOC Patch Panel 2 P1E-P1F PIE•PIE Alcove Or Pretest 2 DOC Patch Panel 2 P2A.P2B P2A-P2B Akove Or Pretest 2 DOC Patch Panel 2 P2Ci20 P2C-P2D Alcove Or Pretest 2 00C Patch Panel 2 P2E-P2F PZE-P2F Pretest 3 DDC Patch Panel 2 P3A-P313 P3A-P3B Pretest 3 DOC Patch Panel 2 PX-P3D P3C430 Pretest 3 DDC Patch Panel 2 P3E-P3F P3E-P3F OD Reception DDC Patch Panel I RI RI OD Reception DOCPaId, Panel 1 R2 R2 OD Reception DDC Patch Panel 1 R3 R3 Exam Desk 1 DDC Patch Panel 2 ElA & E18 EMA & E1B Exam I Recessed Box DOC Patch Panel 1 EtC tIC Exam Desk DOC Patch Panel 2 E2A&E28 E2A&E28 ham 2 Recessed Box DOC Patch Panel 1 EX E2C Exam Desk DOC Patch Panel I E3A&E36 E3A&E3B Exam 3 Recessed Box DOC Patch Panel I E3C E3C Wireless Access Point l DOC Patch Panel 1 API API Wireless ACCOSS Pont 2 DOC Patch Panel 1 AP2 AP2 6-Port Data lack Above DDC DOC Patch Panel 1 1 1 6-Port Data lack Above DOC DOC Patch Panel I 2 2 6-Port Data lack Above DOC DoC Patch Panel 1 3 3 6-Port Data lack Above DOC DOC Patch Panel 1 4 4 6-Port Data lack Above DOC DOC Patch Panel 1 5 5 sport Data Jack Above DOC DOC Patch Panel 1 6 6 LensCrafers Backboard DOC Patch Panel 1 CM CM LensCrafters Backboard DOC Patch Panel 1 BB BB CIARIFYE CHECKLIST REV D.O.xlsx Page 1 of I FLOOR FINISH(##) BOXES ❑ BRASS .c ALUMINUM ■ BLACK ■ GRAY AS REFERENCED ON THE PLAN SHEETS RECESSED FURNITURE FLOOR BOX O SYSTEMONE FLOOR BOX HUBBELL CFBS1R4PF8W/CUP O SYSTEMONE FLOOR BOX HUBBELL Si PFB SUB SYSTEMONE SUB -PLATE Si R4SP2X2DUPLEX OPLATES SYSTEMONE SUB -PLATE HUBBELL S1SPFF## COVER / FLANGE CFBSI R4CVR## (CARPET) POKE FINISH (4#): THRU FITTINGS ❑ BLACK ■ GRAY .t ALUMINUM ■ BRASS AS REFERENCED ON THE PLAN SHEETS RECESSED FURNITURE POKE THRU FITTING WIREMOLD EVOLUTION SERIES 6AT POKE THRU SIPTFIT THRU POKE SUB PLATES 0 TWO RECEPTACLES TO FOUR DUPLEX AND UP DATA OUTLETS eon SYSTEMONE SUB -PLATE HUBBELL SISPFF## COVER / FLANGE () 6CTC2##(CARPET)/ 6CT2## (TILE) E008 LC ST1.0 FLOOR BOX / POKE THRU SCHEDULE FILE COPY IPr cost No. �L / 9 /CIO 7 Plan review approval is subject to errors and "1l$$lons Approval of construction documents does tot auth vize the violation Of any aoored Code or ardlnarce Receipt of approved Feld CooY and conditions IS acknowledged: By Data City of Tukvwra BUILDING DIVISION ' (I\T o xrr^ DES GN ENG \EERING CONSTRICT ON MANAGEMENT. NEXTORE • 4'rc., ,rar'rx Mem-.cnnua .,coil rm e'.ec a e(e,.es. 333E 1.3r,✓st. Cr 91.3,6 9.1.&C 131 9'00 STORE #79779 SOUTHCENTER MALL S PACE #416 SEATTLE, WA 98188 Constructionffoorr- s' J O O W O `4?- r0� U C Co` �NN J N 1�IN L GJ a-� U ri3 r \ O a V J Ox ZIn 0O W¢V Revisions: Mark Date By A 2-18-19 LANOtOW COMMENTS Q 2-28.20 BUILDING DEPARTMENT CCMMENTS A8.14-2020 ON''ER COMMENTS Q 8-27-2020 OWNER COMMENTS Q Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 Seal Architect / Engineer Job No.: 029 Nextore Store Design Revision No.: 05 Nextore project Number 79779_ REQUIRED FOR' Eir Mechanical Brand Design Type: ❑ ElecLrical LC.05 Ca. -Pimping arbas Piping /� I�SSUED FOR: City of TUkwi!a instruction ((((///•-/ter HEV EWED F& t COMPLIANCE WITr, NFPA 70-NEC f fR COT 2` 202654, �" City of TuKwiI .. BUILDING DIVISIGtw Title ELECTRIC /6" GENERAL NC & DETAILS Date Sheet 12-9-19 Drawn By STAFF Checked By MPR E001 05803-00 LC-05803-00 CASH DESK RIGHT 02/24/2020 1 .._-1 n I e_. 00411-01 9" 2 3" .I 1 6"-j' 00411-01 OKS-00411-01 WALL UNIT 54" Electrical Requirements Driver #1 (wattage): 90 W Driver #2 (wattage): 90 W Driver #3 (wattage): 90 W Driver #4 (wattage): Total LED Lighting Watts 238 W finished floor 05401-00 LC-05401-00 WALL UNIT 48 WITH MIRROR 02/24/2020 05832-00 MEI ���lr 05821-00 LC-05832-00 BACKWRAP CABINET OD AREA LC-05806-00_OD RETAIL CAS DE EFT finished floor 05431-00 00422 OKC-00422-00 CUSTOM LC-05431-00 WALL UNIT 24 WITH MIRROR 02/24/202 OUTLET TO BE SWITCHED. 03400-01 RB-03400-01 _ WALL UNIT 48" 05/04/2020 05432-01 LC-05432-01 WALL UNIT 24 LAC 02/29/2020 05450-00 02/24/ LC-05821-00 BACKWRAP CABINET 4X55" 02/24/2020 OUTLET TO BE SWITCHED. DIWPQO0-LOC1 RB-03402-01 _ WALL UNIT 24" 05/04/202 GEN-DIGM01-00 GEN-DIGM01-00-LOC1 02/24/2020 GEN-DIGM01 -00 MIRROR SMART SHOPPER w/MONITOR 46" TOUCH 02/28/2020 12 3" 00216-00 INSIDE TECH RACK OR AT PHONE BOARD - SEE PLANS MONITOR CAMERA (QUANTITY ON PLAN) QUADRUPLEX RECEPTACLE 1. EXTEND CABLE TO PROPOSED HEAD END EQUIPMENT LOCATION. PROVIDE ENOUGH EXCESS CABLE TO REACH ANY WALL IN BACK ROOM. COIL AND MARK CABLE AS CCTV. HEAD END EQUIPMENT LOCATION MUST BE WITHIN 10' OF THE 'NETWORK SWITCH ACCESS'. 2. FOR CAMERAS, PROVIDE WHITE PLENUM RATED CAT 6 CABLING. COIL 15' OF CABLING AT EACH CAMERA LOCATION FOR CONNECTIONS. 3. PROVIDE RJ-45 CONNECTORS AT CAMERA LOCATIONS ONLY. CONNECTORS NOT NEEDED AT THE HEAD END EQUIPMENT LOCATION. 005 CCTV SYSTEM RISER EMERGENCY LIGHTING INVERTER, LINE VOLTAGE IN, LINE VOLTAGE OUT 277V IN HOT I SWITCHED 120V AC 120V IN HOT I SWITCHED AREA LIGHT SWITCH, OCCUPANT SENSOR, ETC. NEUTRAL GROUND E004 2' 3" S-00216-00 _ 54" LIGHTBOX GRAPHIC • LABEL SW1 B LABEL SW2 i LABEL SW3 02/24/202C COMMON IN GND COMMON OUT 120V IN ON [OFF 277V IN ON [OFF E010 120V AC, SWITCHED NEUTRAL AREA EMERGENCY LIGHT FIXTURES. AREA NON -EMERGENCY LIGHT FIXTURES. 1 EMERGENCY LIGHTING WIRING SCHEMATIC WHEN INVERTER IS APPLIED 0 o S a• S LABEL SW4 S LABEL SW5 O LABEL 5W6 Y LABEL SW7 LABEL TO BE PRINTED (WITH A LABEL MAKER), BLACK INK ON CLEAR BACKGROUND. TEXT OF LABEL TO MATCH TEXT OF DESCRIPTION SHOWN IN COIL PORTION OF DETAIL EQUIPMENT CONTROLLED SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING ALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET EQUIPMENT CONTROLLED SALES FLOOR CABINET LIGHTBOX LIGHTBOX LIGHTBOX LIGHTBOX FUTURE FUTURE FUTURE E033 RELOCATED TIMECLOCK 2 CHANNEL. ASTRONOMIC CHANNEL 1 CHANNEL 2 ROUTE THROUGH SWITCHING FOR INDEPENDENT, SECONDARY CONTROL. SEE MASTER SWITCHING DETAIL. COIL 8-POLE SQUARE-D LIGHTING CONTACTOR ELECTRICALLY HELD CONTACTOR "B" [COIL I1 8-POLE SQUARE-0 LIGHTING CONTACTOR ELECTRICALLY HELD CONTACTOR C' CIRCUIT B 24 B26 B28 B 30 B 32 B34 B 36 B2 CIRCUIT B-4 B22 A-40 A-42 B-25 S LABEL SW8 • S O LABEL SW9 E004 DIGITAL TIMER SWITCH FOR COIL BYPASS. SET TIMER TO 2 HOURS. SWITCH ALLOWS STORE OCCUPANTS TO BYPASS THE TIMED SCHEDULE FOR A SET TIME PERIOD. LOAD DESCRIPTION STOREFRONT LIGHTING STOREFRONT RECEPTACLES SALES PERIMETER OUTLETS SALES TRACK SALES TRACK SALES TRACK S STORE EXTERIOR SIGN SWITCH # 2 6 6 N. ICROWAV FRIDGE PLAN VIEW 2 OUTLETS WITH (4) USB PORTS - tHUBBELL US815X2W 24"W X 8- D SHELF MICROWAVE AND FRIDGE FURNISHED AND INSTALLED BY TENANT. DUPLEX OUTLET ON DEDICATED 20A CIRCUIT ELEVATION MICROWAVE, REFRIGERATOR, USB ELEVATION CONNECT TO 0 NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. N 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS #592 E006 E007 NON -SALES BUZZER (ABOVE REAR DOOR) EDWARDS #340-4G5- 24VAC PUSHBUTTON, EDWARDS #852 24V, SYSTEM SALES BUZZER AT CASH WRAP EDWARDS #340-4G5- 24VAC DOOR ENTRY BELL SYSTEM RISER E006 TAG EQUIPMENT FURNISH BY: INSTALLED BY: O WALL SHELF VENDOR VENDOR © AMPLIFIER VENDOR VENDOR © SPEAKER WIRE VENDOR VENDOR Q SPEAKER VENDOR VENDOR © SPEAKER BAFFLE VENDOR VENDOR SOUND SYSTEM RISER SIGN POWER CIRCUIT; SEE PANEL SCHEDULE COIL 10-POLE SQUARE-D UGHTING CONTACTOR ELECTRICALLY HEW CONTACTOR "A' CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS, ELECTRICALLY HELD IN NEMA1 ENCLOSURE. INSTALL ABOVE CEILING (WHEN A CEILING IS PRESENT) WHERE PERMITTED BY CODE. CIRCUIT SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS CO- OC SWITCH BANK AND ASSOCIATED CONTACTORS, PHOTOSWITCH WHEN EXTERIOR CONTROL IS REQUIRED COMPLIANCE WITH} NFPA. 70 - NEC 202Q I City of TNkwi!e I DUILDINGr` DIVISION CEP E033 D DESGN ENG VEERING CONSTRUCTION VANAGFN'r NI. NEXTORE •4E01 mo,u>xe, r/awn. f,no •'I (SI!• T5 ti:W •fi Crer.ey 66-44 F nl 4404 C' llwlb • -1114E. e1 iiIXr STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Construction for. Revisions: Mark Date A 12-18-19 By LANDLORD COMMENTS Q 2-28-20 BULDNG DEPARTMENT COMMENTS Q 8-14-2020 OWNER COMMENTS Q 8,47.2020 OWNER COMMENTS 0 Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 8/28/20 DPRES 41Id1 Architect / Engineer Job No.: 029 Nature Store Design Revision No.: 05 Nextore project Number 79779 Brand Design Type: LC.05 ISSUED FOR: ® Construction Title ELECTRICAL DETAILS Date Drawn 12-9-19 r Checked By Sheet E002 DESIGN ENGINEERING CONSTRUCTION MANAGEMENT: H H H rVT IS I I �I IIEl1D r Jvr a G4 NOTE: SEE ARCHITECTURAL PLAN FOR START POINT. COORDINATE WITH THE GC. PANEL LOAD CALCULATE AT FOUR LOADS AT 1536 VA PER CIRCUIT AND ONE LOAD AT 768 VA. 5 CIRCUITS REQUIRED. 4W x 9H LED WALL (LW02) I I I I I I I I I I I I I I I I I I I I I ► I I I I ► I I I I I I I I I I I I I I I I I I II I I II I I II I I I I _1 liII I I I ►I I I I I1b I IMI I rift,rift,I I Cm rv" I 2D ®I I I 11 •• I I I IE s 2D I e� II ue• Vn' t�nra� r 141N• r ve �VA• 1,i k�} na L NOTE: SEE ARCHITECTURAL PLAN FOR START POINT. COORDINATE WITH THE GC. TWO RECEPTACLES ARE CONNECTED TO ONE CIRCUIT. PANEL LOAD CALCULATE AT 1200 VA PER CIRCUIT. 2 CIRCUITS REQUIRED. 4W x 4H LED WALL (LW01) EC TO ROUTE MC CABLE TO BUILT IN SWITCH IN FRAME OF LIGHT BOX AND CONNECT. THEN EC TO ROUTE WIRING IN FRAME (A LISTED RACEWAY) TO DRIVERS AND CONNECT. DRIVER BY FIXTURE SUPPLIER. SWITCH BY FIXTURE SUPPLIER. E066 LIGHTBOX ELECTRICAL INFORMATION IE066D 11ino C7 O O O E101 OPTICAL STATION 1E101 I . ELECTRICAL INFORMATION 1. 3., 00 00 O 00 00 O 00361-00 0 9.. 02323-00 min 1 05305-00 PP1 05370-00 NO Electrical Requirements OKC-00361-00 OAKLEY PRESCRIPTION TABLE 02/24/2020 B-0 323-00 SOHO A LE LC-05305-00 SELECT TABLE SINGLE 02/24/202 LC-05370-00 TAVOLO PROMO 02/24/20 SIGN IS INSTALLED IN BACKWRAP AND POWER IS SUPPLIED FROM BEHIND BACKWRAP. A I] DS —� E Y' 00201-00 power supply from the ceiling n. 11-1 02201-00 IJPROVIDE JUNCTION BOX AND SWITCH IN ACCESSIBLE LOCATION, ABOVE CEIUNG, TO FEED SIGN. EYE EXAMS 05865-00 PROVIDE JUNCTION BOX AND SWITCH IN ACCESSIBLE LOCATION, TO ABOVE CEILING, TO FEEDDSIGN. J . ENSCRAFTERS 05860-00 OKS-00201-00 _ OAKLEY SIGN HORIZONTAL 02/24 I• RB-02201-00 LIT BIG WAYFARER 02/24/2020 LC-05865-00 EYE EXAM LOGO - SINGLE LETTERS 02/24/2020 LC-05860-00 LC SIGNAGE SMALL 02/24/2020 Imo RB-MTL RB-MTL 02/24/2020 00300-00 k7"t� 1 00300-00 00300-00 02/24/2020 05303-00 NO Electrical Requirements 02/24/2020 A GFI GFI A E103 CONTACT LENS E103 11. ELECTRICAL INFORMATION 13" GFI r E104 CONTACT LENS E1o4 ELECTRICAL INFORMATION 1 t I' 2 OUTLINE OF LOW PROFILE LEVITON 47617-REB, WHITE FINISH, RECESSED ENTERTAINMENT BOX. 1 1/2" CONDUIT ROUTED J CONCEALED FROM ENTERTAINMENT BOX TO JUNCTION BOX AT EXAM DESK. PROVIDE PULL STRING. ELEVATION 4n,ff "it EQ119` EQ108 PLAN VERIFY INSTALLATION OF DEVICES WIN GC PRIOR TO ROUGH IN. DEVICES ARE TO BE ACCESSIBLE - DO NOT INSTALL BEHIND DOORS OR FILE CABINETS. ELEVATION GFI�� EQ100A OPTOS PLAN SE-0D03 WALL JACK FOR PHONE INSTALLATION. SE-OD03 it, SE-CD01_L ELEVATION 1 1/2" CONDUIT ROUTED CONCEALED FROM ENTERTAINMENT BOX TO JUNCTION BOX AT EXAM DESK. PROVIDE PULL STRING. wAjt, "AO _ ,sE=0_D03— SE-0D03 EQ6A SE-OD01 PLAN SE-OD01 DOCTOR'S DESK VERIFY INSTALLATION OF DEVICES WITH GC PRIOR TO ROUGH IN. DEVICES ARE TO BE ACCESSIBLE - DO NOT INSTALL BEHIND DOORS OR FILE CABINETS. o� WALL JACK FOR PHONE INSTALLATION. ,NI -3k \ a 1 1/2" CONDUIT ROUTED CONCEALED FROM ENTERTAINMENT BOX TO JUNCTION BOX AT EXAM DESK. PROVIDE PULL STRING. REFRACTION ROOM EQUIPMENT OUTUNE OF LOW PROFILE LEVITON 47617-REB, WHITE FINISH, RECESSED ENTERTAINMENT BOX. 11/2" CONDUIT ROUTED J CONCEALED FROM ENTERTAINMENT BOX TO JUNCTION BOX AT EXAM DESK. PROVIDE PULL STRING. I REVIEWED FOF1' OOMPLIAiNCE WITH' NFPA 70 - NEC f." 2'' 20E0 011y of TUkwiU- SUILOING DIVISION ELEVATION 24- LQ11�__-�_ ► rn 10 m n EQ108 PLAN EQ109B NEXTORE •.O ..1:Irc, .Ce. N1 v 0+.504: • 6 •-I,SpI'LS Y5 STORE #79779 SOUTHCENTER MALL SPACE #4- 16 SEATTLE, WA 98188 Construction for. Revisions: Marc Date 12-18-19 LANDLOPD COMMENTS Q2-28-20 BUILDING DEPARTMENT COMMENTS A8-14.2020 OWNER COMMENTS Q8-27-2020 OWNER COMMENTS Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 cows 12-01-21 Architect / Engineer Job No.; 029 Nextore Store Design Revision No.: 05 Numbeworat er 79779 Brand Design Type: LC.05 ISSUED FOR: ID Construction Tile ELECTRICAL DETAILS Date Sheet LC001 REFRACTION (EXAM) ROOM ELECTRICAL INFORMATION C001 12-9-19 Drawn By STAFF Checked By MPR E003 V PATCH PANEL "PPA" - 24 PORT (LOCATED AT PHONE BACK BOARD) POS LABEL DESCRIPTION ?OS LABEL DESCRIPTION ?OS LABEL DESCRIPTION ?OS LABEL DESCRIPTION 1 PPA1 WORK COUNTER 7 PPA7 WORK COUNTER 13 PPA13 EXAM ROOM #1 - WALL PHONE 19 PPA19 SPACE 2 PPA2 WORK COUNTER 8 PPAB WORK COUNTER 14 PPA14 EXAM ROOM #1 20 PPA20 SPACE 3 PPA3 WORK COUNTER 9 PPA9 RECEPTION DESK 15 PPA15 EXAM ROOM #2 - WALL PHONE 21 PPA21 SPACE 4 PPA4 WORK COUNTER 10 PPA10 RECEPTION DESK 16 PPA16 EXAM ROOM #2 22 PPA22 ACE _ /� 5 PPAS WORK COUNTER 11 PPA11 RECEPTION DESK 17 PPA17 SPACE 23 �PA2i� SPA ][3 6 PPA6 WORK COUNTER 12 PPA12 SPACE 18 PPA18 SPACE 24 PPA24 SPACE ROUTE CATEGORY 6 CABLING FROM EACH PORT ON THE PATCH PANEL TO THE CORRESPONDING JACK IDENTIFIED ON THE PLAN. ROUTE THE WIRING IN A CODE COMPLIANT FASHION, IN CONDUIT OR IN FREE AIR AS PER THE JURISDICTION REQUIREMENTS. WHERE WIRING IS ROUTED IN FREE AIR, PROVIDE 1-HOOKS AT 6FT INTERVALS MAXIMUM AND NEATLY INSTALL. V PATCH PANEL "PPB" - 24 PORT (LOCATED AT PHONE BACK BOARD) POS LABEL DESCRIPTION ''OS, LABEL DESCRIPTION 70S LABEL DESCRIPTION 70$ LABEL DESCRIPTION 1 PPBI SPACE 7 PPB7 SPACE 13 PPB13 CONTACT LENS 19 PPB19 SPACE 2 PPB2 SPACE 8 PPB8 SPACE 14 PPB14 CONTACT LENS 20 PPB20 SPACE 3 Pe1.3 SPA 9 PPB9 TRAFFIC COUNTER 15 PPB15 SPACE 21 PPB21 SPACE 4 i _� (PP84 SELECTION TABLE 10 PPB10 WIRELESS ACCESS POINT 16 PPB16 SPACE 22 PPB22 SPACE 5 P�nLiAr_ 3 11 PPB11 SPACE 17 PPB17 SPACE 23 PPB23 SPACE 6 (PB6 SPACL 12 PPB12 SPACE 18 PPB1B SPACE 24 PPB24 SPACE J ROUTE CATEGORY 6 CABLING FROM EACH PORT ON THE PATCH PANEL TO THE CORRESPONDING JACK DENTIFIED ON THE PLAN. ROUTE THE WIRING IN A CODE COMPLIANT FASHION, IN CONDUIT OR IN FREE AIR AS PER THE JURISDICTION REQUIREMENTS. WHERE WIRING IS ROUTED IN FREE AIR PROVIDE 1-HOOKS AT EFT INTERVALS MAXIMUM AND NEATLY INSTALL. V PATCH PANEL "PPC' - 24 PORT (LOCATED AT PHONE BACK BOARD) POS I ABFI DESCRIPTION 70$ LABEL DESCRIPTION 'OS LABEL DESCRIPTION 'OS LABEL DESCRIPTION 1 PPC1 IP SURVEILLANCE CAMERA 7 PPC7 IP SURVEILLANCE CAMERA 13i.e.' C1 �IP>SURVEIL�A.FC CAIv 19 PPC19 SPACE 2 PPC2 IP SURVEILLANCE CAMERA 8 PPCB IP SURVEILLANCE CAMERA 14 C14 IP SURVEILLANCE CAMERA 20 PPC2O SPACE 3 PPC3 IP SURVEILLANCE CAMERA 9 PPC9 IP SURVEILLANCE CAMERA 15VPCTS SPACE 3 21 PPC21 SPACE 4 PPC4 IP SURVEILLANCE CAMERA 10 PPC10 IP SURVEILLANCE CAMERA 16 PPC16 SPACE 22 PPC22 SPACE 5 PPCS IP SURVEILLANCE CAMERA 11 PPC11 IP SURVEILLANCE CAMERA 17 PPC17 SPACE 23 PPC23 SPACE 6 PPC6 IP SURVEILLANCE CAMERA 12 PPC12 IP SURVEILLANCE CAMERA 18 PPC18 SPACE 24 PPC24 SPACE ROUTE CATEGORY 6 CABLING FROM EACH PORT ON THE PATCH PANEL TO THE CORRESPONDING JACK DENTIFIED ON THE PLAN. ROUTE THE WIRING IN A CODE COMPLIANT FASHION, IN CONDUIT OR IN FREE AIR AS PER THE JURISDICTION REQUIREMENTS. WHERE WIRING IS ROUTED IN FREE AIR PROVIDE J-HOOKS AT 6FT INTERVALS MAXIMUM AND NEATLY INSTALL. V PATCH PANEL "PPD" - 48 PORT (LOCATED AT PHONE BACK BOARD) POS LABEL DESCRIPTION )'OS LABEL DESCRIPTION "OS LABEL DESCRIPTION 70S LABEL DESCRIPTION 1 PPD1 PERIMETER DISPLAY CASE 13 PPD13 SALES AREA LED WALL 25 PPD25 SALES AREA CASH DESK 37 PPD37 SPACE 2 PPD2 PERIMETER DISPLAY CASE 14 PPD14 SALES AREA LED WALL 26 PPD26 SALES AREA CASH DESK 38 PPD38 SPACE 3 PPD3 PERIMETER DISPLAY CASE 15 PPD15 SALES AREA LED WALL 27 PPD27 SALES AREA CASH DESK 39 PPD39 SPACE 4 PPD4 PE METE.pyDISgLAY CASE 16 PPPP 16 )LES AREA LED S'YALL 28 PPD28 SALES AREA CASH DESK 40 PPD40 SPACE 5 PPDS�P PPD6 METER UISPLAY�ASE 17 WPD17 SALES AREA LED WALL S 29 PPD29 SPACE 41 PPD41 SPACE 6 ( PERIMETER DISPLAY CASE 18 IPPD18 SALES AREA LED WALL i 30 PPD3() LAB 42 PPD42 SPACE 7 PO7 — P v 3 18 PPD19 SPACE 3 31 PPD31 LAB 43 PPD43 SPACE 8 PPPDB S A E. 20 PPD20 �PPPD21 SPACE 32 PPO32 LAB �� 44 PPD44 SPACE 9 PPD9 21 SALES AREA CA�Sr�l K 33 i PPD33 LAB J4\ 45 PPD45 SPACE 10 '''$$$P1510 _SPACE .-. SPACE 22 PPD22 SALES AREA CASH DESK 34 PPD34 SP'XC� 46 PPD46 SPACE 11 PPD11 SALES AREA LED WALL 23 PPD23 SALES AREA CASH DESK 35 PPD3$ SPACE 47 PPD47 SPACE 12 PPD12 SALES AREA LED WALL 24 PPD24 SALES AREA CASH DESK 36 PPD36 SPACE 48 PPD48 SPACE ROUTE CATEGORY 6 CABLING FROM EACH PORT ON THE PATCH PANEL TO THE CORRESPONDING JACK DENTIFIED ON THE PLAN. ROUTE THE WIRING IN A CODE COMPLIANT FASHION, IN CONDUIT OR IN FREE AIR AS PER THE JURISDICTION REQUIREMENTS. WHERE WIRING IS ROUTED IN FREE AIR, PROVIDE 1-HOOKS AT 6FT INTERVALS MAXIMUM AND NEATLY INSTALL. LC002 NETWORK DIAGRAM LENSCRAFTERS EQUIPMENT FURNISHED INSTALLED DATA/TECH RACK EC EC DATA WIRING EC EC PATCH PANELS EC EC DATA JACKS EC EC TRAFFIC COUNTER VENDOR VENDOR DATA WIRING EC EC SURVEILLANCE CAMERA VENDOR VENDOR DATA WIRING EC EC SOUND SYSTEM VENDOR VENDOR RECEPTACLES(UNSWITCHED) EC EC HEAD END EQUIPMENT VENDOR VENDOR SPEAKER WIRING (ACTCEI LING) VENDOR VENDOR SPEAKER WIRING (GYP CEILING) VENDOR VENDOR RACEWAY SYSTEM TO SPEAKERS WHEN A GYP CEILING IS INSTALLED PROVIDE PULL WIRE EC EC SPEAKER VENDOR VENDOR LED WALLS RECEPTACLES (UNSWITCHED) EC EC DATA OUTLETS, TERMINATED AND TESTED EC EC DATA WIRING BACK TO PATCH PANEL EC EC POWER WIRING BETWEEN COMPONENTS VENDOR VENDOR DATA WIRING BETWEEN COMPONENTS VENDOR VENDOR MEDIA PLAYER VENDOR VENDOR MEDIA PLAYER SHELF EC EC PROGRAMMING VENDOR VENDOR TELEPHONE BACKBOARD EC EC CONDUIT FROM LL ROOM TO TENANT SPACE EC/LL PER LEASE EC/LL PER LEASE WIRING FROM THE LL ROOM TO THE TENANT SPACE EC EC PLYWOOD BACKBOARD EC EC BACKWRAP EQUIPMENT D-LINK SWITCH VENDOR VENDOR EQUIPMENT SPECIFICATIONS CATEGORY 6 CABLE: GENERAL CABLE 7141849 PLENUM RATED, BLUE JACKET EC EC LC AND LCM ONLY: CATEGORY 6 MODULAR JACK (WHITE): PANDUITCJ6X88TGW EC EC 24 PORT PATCH PANELS: PANDUITDP246X88TGY EC EC 48 PORT PATCH PANELS: PANDUITDP486X88TGY EC EC EQUIPMENT RACKS EC EC WALL MOUNTED RACK: MIDDLE ATLANTIC WM-15-18 (30"H X 20"W - 15RU) EC EC 1U VENTED SHELF: MIDDLE ATLANTIC U1V 1SP VENTED SHELF EC EC 2U VENTED SHELF: MIDDLE ATLANTIC U2V 2SP Vented Shelf EC EC HORIZONTAL CABLE MANAGEMENT: PANDUITWMPFSE EC EC VERTICAL WIRE MANAGEMENT: LEVITON4940L-VFR EC EC WIRING FROM LL TELEPHONE ROOM TO SPACE: 25 PAIR, CATEGORY Se, PLENUM EC EC GenSPEED® SODO Category Se 25-Pair Backbone Cable, Grey D-LINK AT THEBACKWRAP: VENDOR VENDOR FACEPLATES EC EC TESTING AND REPORTS TESTING OF DATA AND VOICE OUTLETS AND WIRING EC EC PDF REPORT SHOWING COMPLIANCE WITH CATEGORY 6 STANDARD EC EC PDF REPORT TO SHOW OUTLET LOCATION AND TESTING RESULTS EC EC LENSCRAFTERS INUNE ONLY - DOCTOR'S DATA CABINET (DDC) PHYSICAL CABINET NEXTORE GC PATCH PANELS EC EC WIRING FROM PHONE BOARD TO PATCH PANELS EC EC ALL STATION CABLING EC EC MAIN PHONE BOARD DIGITAL EQUIPMENT MIRAKI ROUTER VENDOR VENDOR 66 BLOCK ORBISQUIT JACK UTILITY UTIUTY CONNECTION BETWEEN THE 66 BLOCK AND PATCH PANEL VENDOR VENDOR ANY ROUTERS OR SWITCHES VENDOR VENDOR PATCH CABLES BETWEEN PATCH PANELS AND ELECTRONICS VENDOR VENDOR ANY PATCH CABLES VENDOR VENDOR (2) CAT6 TERMINATE TO DDC 48 PORT PATCH PANEL er NOTES: 1. ALL WORK SHOWN ON THIS DRAWING IS BY THE ELECTRICAL CONTRACTOR. THE ONLY EXCEPTION IS THE DOCTOR'S DATA CABINET WILL BE SUPPLIED BY THE TENANT. 2. PLENUM RATED 4 PAIR CAT6 CABLE TO BE BERK-TEK LANMARK-100Q RATED CMP FOR PLENUM & OSP WHERE USED BELOW SLAB. 3. HOME RUN CABLE TO BACKBOARD 3.1. LABEL TERMINATE AND TEST IN PATCH PANEL. 3.2. CONTINUOUS RUN -NO SPLICES 4. SEE ELECTRICAL/ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 5. EACH COMPUTER (#21) OR FUTURE COMPUTER OR ACCUFIT AT A FITTING COUNTER REQUIRES A HOME RUN CAT6 CABLE TO THE BACKBOARD PATCH PANELS. 6. ROUGH IN TO BE A 4 X 4 BOX WITH SINGLE DEVICE PLASTER RING IN WALL AS PER ARCHITECTURAL DRAWINGS WITH MINIMUM 3/4" CONDUIT TO 6" ABOVE CEILING. TECH PLAN VIEW MINIMUM 10 - ONE INCH CONDUITS FROM 15 INCHES BELOW CEILING TO 24 INCHES ABOVE CEILING FOR CABLE PASSAGE. PROVIDE LONG RADIUS BEND AT THE ABOVE CEILING LOCATION TO ALLOW FOR SMOOTH CABLE PULL. BUSH CONDUIT ENDS TO PREVENT CABLE DAMAGE. CEILING WHEN CEILING IS PRESENT � M _1 RACK MOUNTED 48 PORT PATCH PANELS, QUANTITY OF PATCH PANELS TO MEET PROJECT REQUIREMENTS - SEE PLANS FOR DATA COUNTS. MINIMUM ONE 48 PORT PATCH PANELS REQUIRED. GROUND BAR - PROVIDE #1/0 COPPER TO SERVICE GROUND. QU AD OUTLET ON DEDICATED 20A CIRCUIT FOR VOICE/DATA EQUIPMENT RACK MOUNTED SHELVES m OPEN RACK - 24" WIDE X 36' HIGH (NOMINAL) CABINET WITH DOOR FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 7 48 IN WIDE X 96 IN HIGH X} INCH DEEP FIRE RETARDANT PLYWOOD BACKBOARD. PLAN TUBE DEMARC PHONE PATCH PANEL ASSUMING MINIMUM POINT OF ENTRY DEMARC AND CROSS CONNECT PROVIDE 5" WIDE VERTICAL CABLE MANAGEMENT RACEWAY WITH SIDE FINGERS FOR CABLE PASSAGE. RACEWAY TO HAVE COVER. LEVITON 4940L-VFR OR SIMILAR. RACK MOUNTED PATCH PANEL FOR SURVEILLANCE CAMERAS. 24 PORT TYPICAL. VERIFY WITH ACTUAL PROJECT REQUIREMENTS (ONE PORT REQUIRED FOR EACH CAMERA) QUAD OUTLET ON DEDICATED 20A CIRCUIT FOR SECURITY EQUIPMENT RACK MOUNTED SHELF FOR SECURITY SYSTEM EQUIPMENT. OUTLET TO BE SEPARATELY CONTROLLED WITH A FLOOR RELAY FOR FIRE ALARM CONNECTION (TO SHUT DOWN POWER TO SOUND SYSTEM WHEN FIRE ALARM IS ACTIVATED). RACK MOUNTED SHELF FOR SOUND SYSTEM EQUIPMENT. 36" LONG X4" DIA PVC TUBE FOR AS BUILT PLANS (BY GC) LABEL CABLE WITHIN 2 INCHES OF TERMINATION. WALL MOUNTED EQUIPMENT RACK, CHATSWORTH 11960-712, 19" WIDE, 1Z" DEEP, 24.5" HIGH, BLACK. PANDUIT 24 PORT MODULAR PATCH PANEL, MODEL CPP24FMWBLY PANDUIT 24 PORT MODULAR PATCH PANEL. MODEL CPP24FMWBLY PANDUIT 24 PORT MODULAR PATCH PANEL. MODEL CPP24FMWBLY PANDUIT 48 PORT MODULAR PATCH PANEL. MODEL CPP48FMWBLY V PATCH PANEL "DDC" - 48 PORT (LOCATED IN PRETEST ROOM) ''OS POS LABEL, DESCRIPTION ?OS LABEL DESCRIPTION JABEI DESCRIPTION 'OS LABEL DESCRIPTION 1 WJ1 UDC 6-PORT DATA JACK 13 PIE PRETEST ROOM #1 25 P3E PRETEST ROOM #3 37 E1A EXAM ROOM #1 2 WJ2 DDC 6-PORT DATA JACK 14 P1F PRETEST ROOM #1 26 P3F PRETEST ROOM #3 38 E1B EXAM ROOM #1 3 W13 DDC 6-PORT DATA JACK 15 P2A PRETEST ROOM #2 27 P4A PRETEST ROOM #4 39 E1C EXAM ROOM #1 4 WJ4 DDC 6-PORT DATA JACK 16 P2B PRETEST ROOM #2 28 P4B PRETEST ROOM #4 40 E2A EXAM ROOM #2 5 WJ5 DDC 6-PORT DATA JACK 17 P2C PRETEST ROOM #2 29 P4C PRETEST ROOM #4 41 E2B EXAM ROOM #2 6 WJ6 DDC 6-PORT DATA JACK 18 P2D PRETEST ROOM #2 30 P40 PRETEST ROOM #4 42 E2C EXAM ROOM #2 7 API CEILING ACCESS POINT 18 P2E PRETEST ROOM #2 31 P4E PRETEST ROOM #4 43 loot SPACE 8 AP2 CEILING ACCESS POINT 20 P2F PRETEST ROOM #2 32 P4F PRETEST ROOM #4 44 xxx SPACE 9 P1A PRETEST ROOM #1 21 P3A PRETEST ROOM #3 33 xxx SPACE 45 xxx SPACE 10 P1B PRETEST ROOM #1 22 P3B PRETEST ROOM #3 34 xxx SPACE 46 R1 RECEPTION DESK 11 P1C PRETEST ROOM #1 23 P3C PRETEST ROOM #3 35 xxx SPACE 47 R2 RECEPTION DESK 12 P1D PRETEST ROOM #1 24 P3D PRETEST ROOM #3 36 xxx SPACE 48 R3 RECEPTION DESK ROUTE IN CATEGORY 6 CABLING FROM EACH PORT ON THE PATCH PANEL TO THE CORRESPONDING JACK DENTIFIED ON THE PLAN. ROUTE THE WIRING IN A CODE COMPLIANT FASHION, CONDUIT OR IN FREE AIR AS PER THE JURISDICTION REQUIREMENTS. WHERE WIRING IS ROUTED IN FREE AIR PROVIDE 1-HOOKS AT 6FT INTERVALS MAXIMUM AND NEATLY INSTALL MEWRAKI ROUTER MOUNTED TO WALL ABOVE IPAD CHARGING CABINET, PROVIDED AND INSTALLED BY CLARIFYE DATA INSTALL TEAM IPAD CHARGING CABINET PROVIDED AND INSTALLED BY CLARFIVE DATA INSTALL TEAM DRYWALL RING FOR NETWORK CABLING. ALL CLARIFYE NETWORK CABLES TO BE ROUTED TO THIS LOCATION. Biz N 10" U, in PATCH PANEL"PPA' PATCH PANEL"PPB" BOH-DDC 48-PORT CAT6 PATCH PANEL SUPPLIED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. PROVIDE 2RU WALL MOUNTING BRACKET FOR PATCH PANEL CLARIFYE 8-PORT MANAGED ETHERNET SWITCH •®8 2 GANG DRYWALL RING. FIELD 1 N. N. N. \ �\ \ N, LOCATE IN NON DEMISING WALL BEHIND DDC.• DOCTOR SWITCH - •/ ««ig///<i«,A r / • CLARIFYE MODEM — PATCH PANEL "PPC" PATCH PANEL PPD t. ( . c • • T \ \ `\ \ / DDC SIDE VIEW (CROSS SECTION) (2) CAT6 TERMINATE TO DDC 48 PORT PATCH PANEL er PATCH PANEL "DDC" frtt tt NON DEMISING WALL BEHIND DDC. FIELD LOCATE 2 GANG DRYWALL RING IN THIS WALL. / / / / / / / / / / / / / / / / /// CLARIFYE ROUTER CLARIFYE SWITCH MERAKI MS200 MANAGED SWITCH MERAKI MX64 ROUTER \\\\\\\\\\\\\\c\ NON DEMISING WALL BEHIND DDC.— FIELD LOCATE 2 GANG DRYWALL RING IN THIS WALL. OPTICIAN'S NETWORK CAT6 (QUANTITY AS NEEDED), PLENUM RATED CABLE. PANDUIT 48 PORT MODULAR PATCH PANEL. MODEL CPP48FMWBLY PANDUIT WBH3, WALL MOUNT, HINGED BRACKET, INSTALLED IN DDC CABINET. \ \ PATCH PANEL "DDC" THE EQUIPMENT IS ALL BY GC/EC. NOTE THE SPECIFIED PATCH PANELS ARE MODULAR, SO THE PANDUIT CAT6 JACK IS REQUIRED WITH THIS SYSTEM. THE JACK SNAPS INTO THE PATCH PANEL. H 48"X96" PHONE BOARD. INSTALLED 24 INCH AFF TO BOTTOM. DDC TOP SHELF -TOP VIEW 7 / / / / / / DOCTOR ROUTER DOCTOR SWITCH / / / LINKSYS / // E2500 D-LINK / / / DGS1008-G r✓ / NNNNNNNNNNNNNN. DDC MIDDLE SHELF -TOP VIEW NON DEMISING WALL BEHIND DDC. FIELD LOCATE 2 GANG DRYWALL RING IN THIS WALL. CLARIFYE MODEM DDC BOTTOM OF CABINET -TOP VIEW E 4X4 BOX IN WALL WITH — SINGLE GANG ACTIVATION FOR DATA OUTLET. / / / / / / WHERE FREE AIR WIRING IS PERMITTED BY THE LANDLORD AND LOCAL JURISDICTION, UTILIZE 1-HOOKS SPACED PER TIA/EIA STANDARDS. WHERE CONDUIT IS REQUIRED, SIZE PER FILL CHART. ROUTE CONDUIT 6' ABOVE WALL AND BUSH END. SIZE CONDUIT PER FILL CHART. LABEL CABLE WITHIN 2 INCHES OF j TERMINATION. LABEL EACH OUTLET TERMINATE REQUIRED NUMBER OF JACKS AND Ei TEST. PLATE FINISH TO MATCH ADJACENT RECEPTACLE FINISH. FIE EWEC Fbc< I OOMPLI NCE W'Tk, N#R#70-NEC 2)1i I City et T.Ekwi'a BUILDING DIMS'.: MAXIMUM ALLOWABLE CONDUIT FILL (AUGMENTED CAT6) 3/4" C 1"C 1 1/4"C 1 1/2"C 2"C 2 DATA CABLES 4 DATA CABLES 7 DATA CABLES 10 DATA CABLES 18 DATA CABLES CONDUITS TO BE 3/4" UNLESS NOTED OTHERWISE. WHERE REQUIRED BY CODE OR LANDLORD, ALL LOW VOLTAGE WIRING TO BE IN CONDUIT. Lig% /067 LC003 COMMUNICATIONS RISER ELECTRICAL INFORMATION 4> DESGV EVG.V _i TIV:i CONS IRuCTON VAVAGEVENT. NEXTORE • 443:O i..Frra +.re V nvv . D-14104- • -1011.'65 6SO • 66a6Yor, 4'uh t4r:, -c cnve. • .J Wq N,-0lm STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Construction for Revisions: Mark Date A 12-18-'9 BY LANDLORD COMMENTS A 2-28.20 BUILDING DEPARTMENT COMMENTS AB-14-2020 OWNER COMMENTS AB-12.2020 OWNER COMMENTS A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 EIS 1ta�il Architect / Engineer Job No.: 029 Nextore Store Design Revision No.: 05 Nextore project Number 79779 Brand Design Type: LC.05 ISSUED FOR: ® Construction Title ELECTRICAL DETAILS Date 12-9-19 Drawn By STAFF Checked By MPR Sheet E004 ] LC-05432-00 WALL UNIT 24 LAC jLC-05401-00 WALL UNIT 48 WITH MIRROR ELECTRIC ONE LINE DIAGRAM NOTE FIELD VERIFY ALL CONDITIONS DES GNIr NG NEE RINK, CONSTR-CT'C\ VAN AGEMENT a. n ail ®II 05432-00 r- Electrical Requirements Driver 41 (wattage): 90 W Driver 42 (wattage): 90 W Driver 43 (wattage): 90 W Driver 44 (wattage): Total LED Lighting Watts 238 W MIN -sal -� L-_-_1_- ,asZ Ia4,.2gl sv. QSa QQ 42S 4 S. gCL ¢SUP-SZ? s.7s .c.7S.7.j 5'S" igitEtgapiagiii 1 I I finished floor 05401-00 LC-05432-00 WALL UNIT 24 LAC LC-05401-00 WALL UNIT 48 WITH MIRROR GEN-DIGM01-00 MIRROR SMART SHOPPER w/MONITOR 46" TOUCH 4-3i" le--110" -19 ALiti GEN-DIGM01-00-LOCB GEN-DIGM01-00 MIRROR SMART SHOPPER w/MONITOR 46" TOUCH 1 LC-05431-00 WALL UNIT 24 WITH MIRROR 5' 5" rowamill finished floor 05431-00 Electrical Requirements Driver 41 (wattage): 90 W Driver 42 (wattage): 90 W Total LED Lighting Watts 119W F.X. (4)* 600 MCM & (1) 03 GRD IN 3-1/2" C EXISTING METER &400 AMP FUSED DISCONNECT. VERIFY CONDITION. EXISTING LANDLORD ELECTRICAL SERVICE EXISTING ELECTRICAL SERVICE 120/208V, 3PH, 4W LANDLORD (4) it 600 MCM & (1) #43 GRD IN 3-1/2" C TENANT NEW 50A/NF/WP/311t NEW RTU-1 NEW 35A/NF/WP/3P -111 NEW HP-1 (OUTDOOR) NOTE: VERIFY THAT THERE ARE WP/GR RECEPTACLES NEAR NEW RTU AND NEW HEAT PUMP. IF NOT, PROVIDE NEW WP/GFI RECEPTACLES, CIRCUIT TO A-6. TENANT #F696 NEW (3) 4'8 &= (1) 410 GRD IN 3/4" C. NEW (3) 48 & (1) 410 GRD IN 3/4" C. NEW 20A/NF/WP/1P reWITH 15A FUSES NEW FC-1 (INDOOR) ROOF PROVIDE SPLICE BOX TO EXTEND CONDUIT AND CONDUCTORS TO RELOCATED PANELS. RELOC. PANEL 'A' 120/208V, 3 PHASE, 4W 400A MCB RELOCATED TIME CLOCK NEW PANEL'8' 120/208V, 3 PHASE, 4W 400AMP MLO NEW (3) 412 GRD IN /2' C (4) 4600 MCM & (1) # 3- GRD &(1) 43 ISOLATED GROUND IN 3-1/2" C. RELOC. FACP CEILING FIRST FLOOR NOTES: 1. ALL EQUIPMENT SHALL BE SERIES RATED. 2. IF THERE ARE ANY DISCREPANCIES WITH THESE PLANS, PLEASE CONTACT THE ENGINEER 3. PANELBOARDS, METER SOCKET ENCLOSURES. ETC... THAT ARE LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS PER NEC 110.16. (1) 41/O GRD IN 1" C TO eir BUILDING STEEL PER N.E.C. COMMISSIONING NOTE: SET TIMECLOCKS TO CONTROL DISPLAY WINDOW CIRCUITS AND SIGNS PER MALL OPERATION HOURS. PROVIDE FIRE STOPPING FOR ALL PENETRATIONS OF FIRE WALLS. PROVIDE THROUGH WALL FIRE STOPPING FOR ALL LOCATIONS WHERE JUNCTION BOXES ARE LOCATED IN A DEMISING WALL OR OTHER FIRE WALL LC-05431-00 WALL UNIT 24 WITH MIRROR 00300 00 jr7y -jc- 1 r 00300 00 RB-02704-00SMART SHOPPER FOR SHOP IN SHOP )`1. 11 t '--1 I I 02704-00 1 1 DLC-05305-00 SELECT TABLE SINGLE 05305-00 RB-02704-00_ SMART SHOPPER FOR SHOP IN SHOP LC-05305-00 SELECT TABLE SINGLE 00300-00 ILC-05450-00 MIRROR 24 IOKC-00361-00_OAKLEY PRESCRIPTION TABL 1' 3" 9" 00 00 L 00 00 0 00361-00 05450-00 OKC-00361-00_OAKLEY PRESCRIPTION TABLE LC-05450-00 MIRROR 24 DESIGN DRAWINGS ARE SCHEMATIC. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECFCCARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GENERAL CONTRACTORS COST. BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GENERAL CONTRACTORS COST BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. ELECTRICAL LOAD SUMMARY PANELS "A" & "B" LOAD DESCRIPTION LIGHTING TRACK UGHTING SHOW WINDOW RECEPTACLES SIGN CONNECTED LOAD (KW) 1.66 3.66 0.72 1.20 DEMAND FACTOR 1.25 CURRENT LIMITED 1 1.25 DEMAND FACTOR (KW) 2.08 3.66 0.72 1.50 I\DCFORE •hW i,.F.ren T„nM 944504C • 6: re.non a-ccL,an va,nr. l' M'M •-I(IlI '65 v'%e STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Construction for. RECEPTACLES EQUIPMENT WATER HEATING 44.58 1.50 6.00 <1OK=100%; >10k=101t+50%>10k 1 1.25 27.29 1.50 7.50 HVAC TOTALS: AMPS (208V) 30.05 89.37 248.35 1.25 OF LARGEST MOTOR TOTALS: AMPS (208V) 33.83 78.07 216.96 Panel Name: Voltage: Amps: MAIN: RELOCATED PANELA 120/208 400 MCB MAIN CIRCUIT BREAKER Panel Type: PANELBOARD AIC Rating: 1C4( NOTE: ALL BREAKERS SHOWN BOLD TO BE NEW WATTS PER PHASE WATTS PER PHASE Load Characteristics: Total Load, Phase A: Total Load, Phase B: Total Load, Phase C: Total Panel Load: 27432 33895 28039 89366 DESCRIPTION OF LOAD IJGHTING - SALES TRACK LIGHTING - SALES TRACK LIGHTNG - SALES TRACK UGHTNG - SALES TRACK LIGHTING - SALES TRACK UGHTNG - OD RIU RECEPT, RP UGHTNG - SHOW WINDOW RECEPTACLES - SHOW WINDOW SPARE RECEPTACLES -EXAM RECEPTACLES - EXAM RECEPTACLES -PRETEST RECEPTACLES -PRETEST RECEPTACLES -PRETEST RECEPTACLES -PRETEST RECEPTACLES - DOCTORS CABINET RECEPTACLES -DOCTORS CABINET RECEPTACLES -MANAGERS DESK RECEPTACLES -MANAGERS DESK RECEPTACLES -GENERAL OCPD 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 Voltage (360 for 120/208) 360 Amps per Phase A: Amps per Phase B: Amps per Phase C: Total Amps (assumes balanced): 76 94 78 248 CICTR 1 3 5 7 9 11 13 15 17 19 21 23 27 29 31 33 35 37 39 _41 CO* 2 4 6 S 10 12 14 16 18 20 22 24 26 2E 30 32 34 36 38 40 42 OCPD 15/2 20/1 30/3 50/3 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 DESCRIPTION OF LOAD NEW PC-1 [INDOOR) RECEPTACLES - ROOF TOP NEW HP-1 (OUTDOOR) NEW RTU-1 RECEPTACLES - RECEPTACLES • RECEPTACLES- RECEPTACLES- RECEPTACLES- RECEPTACLES- RECEPTACLES- RECEPTACLES- RECEPTACLES- EWC RECEPTACLES- RECEPTACLES - REFRIGERATOR MICROWAVE FRAME WARMER LAB LAB LAB LAB CONTACTS CONTACTS LIGHTBOX UGHTBOX A B I C 832 252 501 1346 Totals 96 10 r 10487 Panel Name: NEW PANEL B Voltage: Amps: Main: 120/208 400A MLO WATTS PER PHASE Load Characteristic: Total Load, Phase A: 13517 Total Load, Phase B: 1rTe1e Total Load, Phase C: 10645 Total Panel Load: 42068 MAIN LUG ONLY DESCRIPTION OF LOAD RELOCATED FACP EXTERIOR STORE FRONTSIGN RECEPTACLES - LED WALL RECEPTACLES- LEO WALL RECEPTACLES -LED WALL RECEPTACLES - LED WALL RECEPTACLES - LED WALL RECEPTACLES - LED WALL RECEPTACLES - LED WALL RECEPTACLES - UGHT BOX RECEPTACLES - UGHT BOX SPARE SPARE SPARE SPARE SPARE ERV-1 RECEPTACLES- PHONEBOARD RECEPTACLES- PHONEBOARD SPARE ERV HEATER OCPD 20/1 20/1 20/1 40/2 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 CKT4 1 3 5 20/1 7 9 11 13 is 17 19 21 23 25 27 29 31 33 35 20/1 37 20/2 20/1 Panel Type: PANELBOARD AIC Rating: 10K CKT# 2 4 6 a 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 39 40 41 42 43 20/1 45 20/1 7 20/3 Voltage (360 for 120/208) 360 Amps per Phase A: Amps per Phase 8: Amps per Phase C: Total Amps (assumes balanced)- 38 so 30 117 44 46 OCPD 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 DESCRIPTION OF LOAD RECEPTACLES- FLOOR DISPLAY RECEPTACLES- FLOOR DISPLAY RECEPTACLES - RECEPTACLES- RECEPTACLES - RECEPTACLES - RECEPTACLES - RECEPTACLES - RECEPTACLES - FLOOR DISPLAY RECEPTION BACKWRAP RECEPTION DESK RECEPTION DESK CASHWRAP BACKWRAP CASHWRAP CASHWRAP 20/1 SPARE SPARE RECEPTACLES - FLOOR DISPLAY CASE RECEPTACLES - FLOOR DISPLAY CASE RECEPTACLES - FLOOR DISPLAY CASE RECEPTACLES - FLOOR DISPLAY CASE RECEPTACLES - FLOOR DISPLAY CASE RECEPTACLES - FLOOR DISPLAY CASE RECEPTACLES - FLOOR DISPLAY CASE RECEPTACLES - FLOOR TABLE 20/1 RECEPTACLES - FLOOR TABLE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 RECEPTACLES - FLOOR TABLE 20/1 20J1 20/1 RECEPTACLES - FLOOR DISPLAY CASE SPARE 4 SPARE 49 50 20/1 SPARE 51 52 20/1 SPARE 53 54 20/1 SPARE L UL 'p GOMP).C. EC NCPc.C - oJC 1 (I; 1 City of Tukwilo UUILAINOaomslvY Totals 45r' 612r 5040 EL/9- (OP Revisions: Mark Dale By A 12-18-19 LANDLORD COMMENTS A2-28-20 BOLDING DEPARTMENT COMMENTS A8-14-2020 OWNER COMMENTS A8-27-2020 OWNER COMMENTS A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 EKPRES 1241941 Architect / Engineer Job No.: 029 Nextore Store Design Revision No.: 05 Nextore project Number 79779 Brand Design Type: LC.05 ISSUED FOR: 0 Construction Title ELECTRICAL GENERAL NOTES & DETAILS Date 12-9-19 Drawn By STAFF Checked By Sheet E005 MPR GENERAL DEMOLITION NOTES O KEY NOTES - ELECTRICAL DEMOLITION DESIGN ENGINEERING CONSTRUCTION MANAGEMENT: A. B. C. D. E. F. G. H. IN EVERY INSTANCE OF DEMOLITION AND/OR REMODELING, THE EC. SHALL FIGURE A COMPLETE JOB AS NONE OTHER SHALL BE ACCEPTED. THE DRAWINGS ARE TO BE USED ONLY AS A GUIDELINE FOR DEMOLITION. THE E.0 MUST VISIT THE SITE PRIOR TO BIDDING TO VERIFY ALL WORK REQUIRED FOR A COMPLETE JOB & INCLUDE THE COST OF SUCH WORK IN HIS BID. THE E.C. SHALL MAINTAIN EXISTING SERVICES TO & IN THE EXISTING AREA AS REQUIRED. IF NECESSARY, THE E.0 SHALL PROVIDE TEMPORARY SERVICES IN THE EXISTING AREAS. THE E.C. SHALL DISCONNECT & REMOVE ELECTRIC SERVICE TO ALL MECHANICAL EQUIPMENT BEING REMOVED AS A RESULT OF THE REMODELING. ELECTRICAL EQUIPMENT & DEVICES SHALL BE REMOVED COMPLETE INCLUDING CONDUIT & WIRE. FLUSH MOUNTED WALL OUTLETS SHALL BE REMOVED AND THE WALL PATCHED AND FINISHED TO MATCH THE ADJACENT WALL FINISHES. ANY EXISTING CONDUIT, WIRING AND/OR ELECTRICAL & MECHANICAL DEVICES BEING DISTURBED BY THE WORK SHALL BE REWORKED BY THIS CONTRACTOR AS REQUIRED TO RETURN TO ITS FORMER EXISTING OPERATING CONDITION. I. ANY CIRCUITS FEEDING THROUGH DEVICES OR EQUIPMENT BEING RELOCATED, REWORKED, OR ABANDONED & SERVING OTHER ELECTRICAL DEVICES, AND/OR EQUIPMENT SHALL BE MAINTAINED BY PROVIDING 1-BOXES OR OTHER ACCEPTABLE METHOD AS REQUIRED. J. ALL WALLS, CEILINGS, FLOORS, ETC., BEING DISTURBED BY THE WORK SHALL BE RETURNED TO FINISHED CONDITIONS TO MATCH EXISTING BY THE E.C. & HE SHALL DO HIS OWN CUTTING & PATCHING AS NECESSARY UNDER HIS CONTRACT. K. L EXISTING MATERIALS SHALL BE TURNED OVER TO THE OWNER. IF NOT REQUIRED BY OWNER, THE E.C. SHALL REMOVE THESE MATERIALS FROM THE PREMISES. NO CONDUIT, BOXES, WIRING, OR CABLES SHALL BE INSTALLED WITHIN 1 1/2" OF THE LOWEST POINT OF THE UNDERSIDE OF THE ROOF DECKING, NOR SHALL THEY BE INSTALLED CONCEALED WITHIN METAL -CORRUGATED ROOF DECKING. THE E.C. SHALL BE RESPONSIBLE TO REPLACE AND/OR REWORK EXISTING CONDUIT, BOXES, WIRING, AND CABLING THAT IS NOT IN COMPLIANCE WITH THIS REQUIREMENT. M. ALL CONDUIT AND CABLING SHALL BE PROPERLY SUPPORTED AS REQUIRED BY THE NATIONAL ELECTRICAL CODE THE E.C. SHALL BE RESPONSIBLE TO REPLACE AND/OR REWORK EXISTING CONDUIT AND/OR CABLING THAT IS NOT IN COMPLIANCE WITH THIS REQUIREMENT. N. EC. SHALL FIELD VERIFY SLAB ON GRADE FLOOR CONSTRUCTION TYPE PRIOR TO CUTTING. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR CUT A STRUCTURAL FLOOR SLAB THICKER THAN FOUR (4") INCHES WITHOUT PRIOR WRITTEN APPROVAL FROM ENGINEER OF RECORD. NOTIFY ENGINEER OF RECORD OF ANY SLAB THICKNESS GREATER THAN FOUR (4") INCHES PRIOR TO PROCEEDING WITH ANY SAW CUTTING. 1. DISCONNECT AND SALVAGE EXISTING PANELBOARDS AND TIMECLOCKS. 2. DISCONNECT AND REMOVE ALL EXISTING LIGHT FIXTURES. 3. REMOVE DEVICES ON WALLS TO BE DEMOLISHED. VERIFY EXACT QUANTITY ON SITE. 4. DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES, SWITCHES ETC AS REQUIRED TO PROVIDE THE ELECTRICAL AS SHOWN ELSEWHERE ON THESE PLANS. 5. DISCONNECT AND REMOVE EXISTING SHOW WINDOW RECEPTACLES. 6. DISCONNECT AND REMOVE EXISTING CEILING FAN. SALVAGE CIRCUITS FOR REUSE. 7. DISCONNECT AND REMOVE EXISTING PHONE BOARD. ALL EQUIPMENT ON PHONE BOARD TO BE SALVAGED AND RELOCATED TO NEW PHONE BOARD LOCATION. SEE SHEET E201 FOR NEW LOCATION. 8. EXISTING DEVICE TO REMAIN. MOVE DEVICE IF THE DEVICE INTERFERES WITH NEW STORE FRONT. VERIFY IF THE DEVICE IS A LL DEVICE AND IF SO CONTACT LL BEFORE MOVING. 9. DISCONNECT AND SALVAGE EXISTING FIRE ALARM DEVICES FOR RELOCATION. SEE SHEET E201 FOR NEW LOCATION. 10. DISCONNECT AND REMOVE EXISTING SECURITY DEVICE. 11. DISCONNECT AND REMOVE POWER TO EXISTING WATER HEATER 12. EXISTING DOOR BELL PUSH BUTTON TO REMAIN. 13. DISCONNECT AND REMOVE EXISTING SPEAKERS. 14. DISCONNECT AND SALVAGE EXISTING DOOR BELL SYSTEM FOR RELOCATION. SEE SHEET E201 FOR NEW LOCATION. 16. DI CONNECT AND REMOVE EXISTING T• F IC COUNTER. II •• - • NICAL UNITS. SALVAGE EXISTING CONDUIT AND CONDUCTORS IF POSSIBLE WITH NEW MECHANICAL UNITS . 18. EXISTING MALL LIGHTING TO REMAIN. MOVE LIGHTING IF THE LIGHT INTERFERES WITH NEW STORE FRONT. CONTACT LL BEFORE MOVING. 19. DISCONNECT AND REMOVE EXISTING LAB EQUIPMENT. 41) Azi jr,,or 41, atniss) ey /14 tar G I O—$ r LC 1 —nail I0 i ��rt--1 II II II III I ] I I Ito 1 L_J I I L_J I r 0©00 :I • fir, ©©00 (TYR) — J L _ _ YP.) r I L_J 0000 (TYP.) 0 -� r I I L_J 0000 (TYP.) 0 e i Ti T1 r Ir II u— r I I L_J (s-N a LJ En r--h I II LL; J (Sl 831 r-� I I L_J - Q L a r-i r 1-I I r I I IL_J 1 I L_J r-� 1 I MOTION DETEC r OR ❑M ❑V FA. STROBE L_J (s-\r —l I fri r �- TT I 7- t _IJ L_4> t. / I // // \ / / / - L--- I, I rs-N \ l � / \z,r 01 0 ❑V I] 0000 (TYP.) 0 ©©00 r-i I I L_J ©000 (IYP.) 0 r-i I I L_J 0000 (TYP.) A \ \ / / I I ♦♦ \\\\ \�_� // L_J ♦ • \ / S. ♦ \\\ / V p \\�// >// // \ // 0000 mP.) r I I L_J r I n ©000 r I I L_J a 0000 0 (TYP.) r I— -' L_J WLE w❑ r I I L_J of -� L_J ©©ooe / / \\ / / \__�/ / \\ \ / \\ // _ - I - I 1 I \\\ \ �I I \\ L_J I L_J I I \ \ `\ I• 2 \\ • •\ \ \ / \•\ \ )r')---J \- --J I \ v L r-� I I L_J r I L_J d _V_!_ _V_ -_7--9_ i ,1 L_J (s-\ ✓ -� I I L_J 66 Is ✓ I ___j L_J a V1 0 C 0,5 Ain0 M 000 (TYP r-� L_J , I mPJ fl I I I r--i I I I I J 0000 000 a? J I I I I q -00 tVIEWrFOF± OA-1MPLitioca ;ART... gdcgc. To - NEC �,-.7/,. aty Of Tuirr4E.,i3UILDING DIVISION SORE /MO Lmenca Mn Mason. CH40MC 6Geerrch Beek Fast GMar. C"CE.V6 ▪ .+ 6333ws<acO O .1 MC) 4319700 STORE #79779 SOUTHCENTER MALL SPACE //416 SEATTLE, WA 98188 Construction for V / 8 Cl 3 W 2ic V O N IE LL O x O x L N2 O Ei: V V J O ZnD � O way Revisions: mare Dale By A 12-18-19 LANDLORD COMMENTS Q2-28-20 BUILDING DEPARTMENT COMMENTS A8.14-2020 OWNER COMMENTS A 8-27.2020 OWNER COMMENTS A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 EXPIRES 120811 Architect / Engineer lob No.: 029 Nextore Store Design Revision No.: 05 Nextore project Number 79779 Brand Design Type: LC.05 ISSUED FOR: ED Construction Title ELECTRICAL DEMOLITION PLAN Date Sheet 1 ELECTRICAL - DEMOLITION SCALE. V4'=T-0• /C6 12-9-19 Drawn By keSJAFF Chec By MPR E100 GENERAL NOTES LANDLORD NOTES LANDLORD REVIEW COMMENTS 11/25/19 NOTE e KEY NOTES - LIGHTING PLAN DESIGN ENGINEERING CONSTRUCTION MANAGEMENT: A. EMERGENCY (EM) LUMINAIRES THAT ARE NOT WIRED TO A CENTRAL INVERTER SYSTEM NOR SHOWN WITH "NC' SHALL BE CIRCUITED WITH AN -UNSWITCHED HOT' TO PROVIDE CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. B. ALL NIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING C. IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR D. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. E. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. F. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. G. LIGHTING CIRCUITS UP TO 10O-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. H. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE THRU-WIRING WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE I. E.C'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY NEXTORE. E.0 IS RESPONSIBLE TO ENSURE THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.0 J. EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. K. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. L E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. snm, LIGHTS N-200 Power Pack `mar 3 3 cmva aapu a�tuan.:�T.= ,.R r e« e a Pone, Pack WATTSTOPPER MODEL W2000A WATTSTOPPER MODEL W2000A LIGHTS MULTIPLE SENSOR MULTIPLE POWER PACK ICONFIRM W CURRENT MANUFACTURER LITERATURE' LIGHT OS OS: OCCUPANT SENSOR WALL MOUNTED. WHITE L - UNSWITCHED CIRCUIT WALL SENSOM IMMER COMBINATION NOTE: ALL WIRING BY THE ELECTRICAL CONTRACTOR E002 OCCUPANCY SENSOR SCHEMATICS E002 ENERGY CODE - COMMISSIONING I. 2. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE OFFICE AREA: 1.1. OCCUPANCY SENSORS DETECT MOTION AND ENERGIZE THE LOCAL SWITCHING. 1.2. OCCUPANCY SENSORS DE -ENERGIZE AFTER NO MOTION IS DETECTED AFTER A 30 MINUTE DELAY. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE SALES AREA: 2.1. SIGNS, PERIMETER SHELVING AND SALES FLOOR DISPLAY CABINETS ARE ENERGIZED AND DE -ENERGIZED WITH THE TIMER SWITCH OR CONTACTOR CONTROLLED BY TIMECLOCK. E0 q 12 ENERGY CODE - COMMISSIONING SMALL P • IF USED - SPEAKERS SHOULD BE RECESSED - NOT SURFACE MOUNTED. • IF USED ANY PEOPLE COUNTER SYSTEMS MUST BE CONCEALED FROM VIEW AT STOREFRONT. • AU. EMERGENCY AND EXIT LIGHTING IN FRONT OF HOUSE MUST BE EDGE LIT AND HAVE RECESSED BASE - NO SURFACE MOUNTED. • CUT SHEETS OF ALL LIGHTING FIXTURES IN FRONT OF HOUSE MUST BE SUBMITTED TO LANDLORD FOR APPROVAL. CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR SHALL REVISE CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA AS WELL AS CIRCUITS THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT. RECESSED LIGHT FIXTURES INSTALLED IN A PLENUM SPACE SHALL BE PLENUM RATED. LIGHTING AND EMERGENCY LIGHTING POWER DENSITY LOCATION SALES AREA 2448 SQ, FT. EMERGENCY FIXTURE DESCRIPTION 2-LAMP LED ADJUSTABLE DOWNUGHT WATTS 40 QUANTITY 21 CONTROLS TINECLOCK EMERGENCY LIGHTING TOTAL WATTS 840 EMERGENCY UGHTING POWER DENSITY(W/SF. FT.) 0.34 SPACE TOTAL WATTS 2337 LIGHTING POWER DENSITY (W/SF. FT.) 0.95 BACK OF HOUSE 14575Q. FT. LED 2X2 16 7 OCCUPANCY SENSOR 112 BACK OF HOUSE BACK OF HOUSE 106 CLG. HT.=8'-0' DETER STORAGE 11, 116 Un CLG. HT.=9-0' CONTACT LENS ROOM 104 CLG. HT.=9'-0' OD RECEPTION/ WAITING AREA CLG. HT.=10'-0" MALE RESTROOM 112 CLG. HT =8'-0' ALCOVE CLG. HT =8'-0' 1-LAMP LED DOWNUGHT EW PANEL B A-9,A-11 FEMALE IhI� • RESTROOM l-J 111 CLG. HT.=8'-0' HALLWAY #2 CLG. HT.=9'-0' HALLWAY #1 CLG. HT.=9'-0" FUTURE PRE -TEST I115I CLG. HT=8'-0' LOC. PANEL A 0(TYP) CLP-5 RP2. RP1 17 EXAM CLG. HT.= 81-0' RELOCATED TIMECLu K )-6A(1)-7(1)-10 11111111.711111111191111111m11111 IUIIII IIIIII11I111111H111111'L 11101 FUTURE PRE -TEST CLG. HT.= B'-0' 12 OCCUPANCY SENSOR TOTAL BOH (TYP) OS EXAM CLG. HT.= 8'-0' 204 316 0.21 1057 URGENT CARE LAB CLG. HT.=9'-0" ROUTE TO 'SW8' A-9 6AMP 10 ®®xF1S 1HW 1 3 PRE -TEST CLG. HT.= 8'-0' ROUTE TO SWITCH "SW6" A-5 10AMP el el el e2 0 0.72 TE TO ITCH "SW5" P O© ELECTRICAL - LIGHTING SCALE 1/4' • 1'-0' RETAIL SALES AREA CLG. HT.=10'-6' 1. CIRCUIT VIA MASTER LIGHTING SWITCH BANK. SEE DETAIL E033. 2. NEW LIGHTING SWITCH BANK. SEE DETAIL E033. IF LOCATION IS UNDESIRABLE, FIELD VERIFY EXACT LOCATION WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH -IN. 3. ROUTE UNSWITCHED CONNECTION TO EXIT SIGNS AND EMERGENCY DOWNLIGHTS. WHERE FIXTURES ARE SWITCHED, ROUTE ADDITIONAL POWER FROM THE SAME CIRCUIT AHEAD OF ALL SWITCHING FOR POWER LOSS SENSING. 4. PROVIDE OCCUPANCY SENSOR FOR AUTOMATIC SHUT OFF OF ROOM LIGHTING. SEE DETAIL E002. A 5. CIRCUIT ROUTED THROUGH CLP-6A(2)-7A(1)-10A(2) (CURRENT LIMITING SUBPANEL). 6. THE FIXTURES ON THIS RUN ARE BACKED UP BY AN INVERTER . SEE DETAIL FOR WIRING INVERTER WITH A SWITCH. 7. NEW EMERGENCY BATTERY UNITS RP2 AND RP10. WIRE TO CIRCUIT SHOWN. COORDINATE INSTALLATION LOCATION WITH NEXTORE PROJECT MANAGER MOUNT BELOW CURRENT LIMITING PANEL SEE E004. RAY -BAN AREA CLG. HT.=10'-6' I01-I1-11E1100 101E11-1011E111 ROUTE T SWITCH' W8' A-9 RPM OAKLEY AREA CLG. HT.=10'-6' III ll111llll ll 01■ IIIIIII I IIIIIIII IIIIIIIIIIIIIIIIII II IIIIIIIIIII I O INTERIOR STOREFRONT CLG. HT.=12'-7' ROUTE TO SWITCH "SW A-15O E REVIE 1 E O IOOMi=Llt} c 't TacPS.'0-WdC- r s 'City of Tukvrile 5 BUILDING DIVIBIO% NEXTORE • iao3 Lutes Pwe. Mnn01050e • •11511169.6D •6CCI rryacct Enc,Pet% Clmtpb 18.116684rI 97m STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Construction for. Revisions: Mark 0 Dale Ely 12-18-10 LANDLORDCONMENTS A2-28-20 BULGING DEPARTMENT COMMENTS • 8-14-2020 OWNER COMMENTS n 8 27-2020 OWNER COMMENTS A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 DOVES *OM Ardlkatt / Engineer lob No.: 029 Nertore Store Design Revision No.: 05 ject Number 79779 Brand Design Type LC.OS ISSUED FOR: T.E Construction Title ELECTRICAL LIGHTING PLAN Date 12-9-19 Drawn By ByT CheckedF MPR Sheet E200 ® KEY NOTES - ELECTRICAL PLAN 1. NEW WATER HEATER LOCATION. 2. INSTALL OWNER FURNISHED AUDIO SYSTEM INCLUDING CABLE, BACK BOXES, SPEAKERS AND VOLUME CONTROL PROVIDE 3/4' CONDUITS FOR ALL WIRING IF REQUIRED FOR ACCESSIBIUTY, LOCAL CODE OR LANDLORD REQUIREMENTS. INCLUDE ALL WORK REQUIRED FOR A COMPLETE SYSTEM IN BID. WHERE A FIRE ALARM SYSTEM IS PRESENT, PROVIDE RELAY TO DISCONNECT POWER TO MUSIC SYSTEM WHEN FIRE ALARM SYSTEM IS IN ALARM. 3. LOCATION OF THE DOCTOR'S DATA CABINET (DDC). SEE DETAIL LC002 FOR DEVICE INSTALLATION. 4. TELEPHONE TERMINAL BOARD: 4'x8'x3/4" FIRE RATED PLYWOOD, MOUNT TIGHT TO THE CEILING. PROVIDE PHONE BOARD FOR RETAIL SALES SIDE OF SPACE AND DOCTORS/REFRACTION SIDE OF SPACE. SEE DETAIL LC003. 5. PROVIDE POWER AND TELE/DATA FOR FLOOR FURNITURE FEEDS. PROVIDE DEVICES AND DEVICE QUANTITIES AS SPECIFIED IN FIXTURE CUT SHEETS PROVIDED BY FURNITURE MANUFACTURER EC SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS WITH FURNITURE MANUFACTURER REPRESENTATIVE. 6. EC SHALL PROVIDE DATA CABLE FROM TELEPHONE BOARD TO 24" ABOVE CEILING FOR CONNECTION TO SHOPPERTRA( SYSTEM(BY OTHERS). PROVIDE MINIMUM 6 FT COILED CABLE AT BOTH ENDS. SHOPPERTRAKER MUST BE RECESSED STYLE. 7. LOCATION OF DOC (24-PORT CAT 6 PATCH PANEL, CLARIFYE 8-PORT MANAGED ETHERNET SWITCH, DOCTOR SWITCH, DOCTOR ROUTER, CLARIFYE MODEM & CLARIFYE ROUTER). GC SHALL INSTALL A DRYWALL RING BEHIND DDC. ALL DATA LINES RUNNING TO AND FROM DDC SHALL RUN THROUGH DRYWALL RING. OUTLETS IN WALL NEED TO BE LOCATED AT 18" A.F.F. BEHIND THE DDC. ALL CABLE SHALL BE LEFT HANGING LOOSE FOR LUXOTTICA I.T. TO MAKE FINAL CONNECTIONS. ALL CABLES SHALL BE LABELED PER PLAN. SEE DETAIL LC002. B. EC SHALL PROVIDE A-CAT6 DATA CABLE FROM TELEPHONE BOARD TO 24' ABOVE CEILING FOR CONNECTION TO WIRELESS ACCESS POINT. COORDINATE EXACT LOCATION WITH PROJECT MANAGER PRIOR INSTALLATION. 9. FAN TO BE CONTROLLED WITH LIGHT SWITCH FROM ROOM. 10. PROVIDE A RECESSED CLOCK STYLE OUTLET BOX FOR THE RECEPTACLE AND DATA OUTLET AT THE LED WALL. VERIFY EXACT MOUNTING LOCATION WITH NEXTORE PROJECT MANAGER PRIOR TO INSTALLATION. 11. PROVIDE JUNCTION BOX AND DISCONNECT SWITCH FOR 20A SIGNAGE CIRCUIT. SWITCH SHALL SHUT-OFF SIGNAGE CIRCUIT. LABEL SWITCH FOR WHAT IT SERVES. DISCONNECT SWITCHES SHALL BE LOCATED ABOVE CEILING IN AN ACCESSIBLE AREA IN THE BACK OF THE STORE OR AT AN ACCESS PANEL LOCATION AND GROUPED TOGETHER. 12. PROVIDE CORE DRILLING OR TRENCHING (AS APPLICABLE) FOR POWER AND TELE/DATA. EC SHALL VERIFY ALL CORE DRILLING REQUIREMENTS WITH THE LANDLORD PRIOR TO THE START OF WORK. PROVIDE DEVICES AND DEVICE QUANTITIES AS SPECIFIED ON PLANS. E.C. SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS WITH FURNITURE MANUFACTURER REPRESENTATIVE. 13. FINISH OF FLOOR BOXES SHALL BE BRUSHED ALUMINUM. COORDINATE WITH THE G.C. PRIOR TO PURCHASING. 14. CONTROL CIRCUIT THROUGH LIGHTING SWITCH BANK. SEE DETAIL E033. 15. INSTALL LEVITON LOW PROFILE RECESSED ENTERTAINMENT 80X AT LOCATION INDICATED ON ARCHITECTURAL ELEVATION FOR SUPPLY TO DIGITAL EYE CHART. EXACT DIMENSION IS CRITICAL. PROVIDE THE DEVICES INDICATED . PROVIDE ALSO A 1 1/2" CONDUIT FROM BOX TO JUNCTION BOX UNDER THE EXAM DESK. SEE DETAIL LC001. 16. DOOR STROBE/BELL SYSTEM IS COMPRISED OF (3) COMPONENTS. (1) SERVICE DOOR PUSH-BUTTON, (1) STROBE/BELL LOCATED ABOVE GENERAL MANAGER'S (GM) DESK AT AN ELEVATION OF 8'-0", AND (1) TRANSFORMER LOCATED NEXT TO STROBE/BELL. SEE DETAIL E006. 17. PROVIDE NEC 517 REDUNDANT GROUNDING FOR RECEPTACLES AND SWITCHES/DIMMERS IN THIS ROOM. PROVIDE BONDING TO ALL METAL PARTS OF THE RACEWAY SYSTEM TO ENSURE THAT THE RACEWAY SYSTEM ACTS AS A GROUNDING PATH, AND PROVIDE A SEPARATE GROUNDING CONDUCTOR BOND THE CONDUCTOR AND THE RACEWAY TO THE RECEPTACLES TO CREATE A REDUNDANT PATH TO GROUND. USE HOSPITAL GRADE MC CABLE WHEN MC CABLE IS THE WIRING METHOD USED. RECEPTACLES SHALL BE HOSPITAL GRADE. 18. PROVIDE "RECESSED" FLOOR BOX/POKE THRU AT THIS LOCATION - SEE DETAIL EOOS. 19. INDICATED RECEPTACLE WILL BE SERVED BY TWO CIRCUITS. LABEL EACH DUPLEX OUTLET WITH THE CIRCUIT SERVING IT. 20. SEE ARCHITECTURAL ELEVATIONS FOR EXACT PLACEMENT OF ELECTRICAL DEVICES. 21. SOUND SYSTEM SPEAKER. SPEAKERS, WIRING AND ACCESSORIES ARE SUPPLIED AND INSTALLED BY THE SOUND SYSTEM VENDOR COORDINATE WORK WITH THE VENDOR PRIOR TO CEILING INSTALLATION. SEE DETAIL EON. 22. PROVIDE FLOOR BOX "RECESSED" PER DETAIL EGOS. PROVIDE CORE DRILLING OR TRENCHING (AS APPLICABLE) AND ROUTE CONDUITS TO WALL. CONNECT TO 24 HOUR CIRCUIT AND ROUTE CAT 6 CABLING TO TECH RACK LOCATION AND LABEL ENDS OF CABLING. 23. G.C. SHALL PAINT SHOW WINDOW RECEPTACLES TO MATCH ADJACENT FINISHES. 24. PROVIDE 120V POWER TO DOOR DETEX SYSTEM. 25. PROVIDE COMMUNICATIONS RACK AT TELEPHONE BOARD. SEE DETAIL LC002. 26. PROVIDE WIRING FOR TENANT INSTALLED SURVEILLANCE EQUIPMENT. SEE DETAIL TDOS. 27. ALL OUTLETS TO MATCH FINISH OF ADJACENT SURFACE. UTILIZE LEVITON RENU SYSTEM. PROVIDE CLEAR LABEL WITH BLACK TEXT, 1/4" HIGH, ON OUTLETS. LABEL TO READ 'SWITCHED'. S REQUIRED, LOCATIONS, AND INSTALLATION DETAILS AT NOTED LOCATIONS WITH NEXTORE PROJECT MANAGER PRIOR TO PURCHASE. 30. VERIFY PLACEMENT OF DEVICES FOR OAKLEY WALL DISPLAY CABINETS WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH -IN. 31. PROVIDE POWER TO RAYBAN ILLUMINATED SIGN. 32. PROVIDE POWER TO OAKLEY ILLUMINATED SIGN. 33. ALL FIRE ALARM WORK TO BE COMPLETED BY THE LL FIRE ALARM CONTRACTOR AT TENANT EXPENSE. CONTRACTOR TO PROVIDE ANY REQUIRED SUBMITTALS AND CONNECTIONS/REPROGRAMMING TO THE LANDLORD PANEL, AS APPLICABLE. 34. PROVIDE MC CABLE WHIP TO BASE OF LIGHT BOX, FROM SWITCH ABOVE CEIUNG, AND CONNECT TO SWITCH IN THE LIGHT BOX (SUPPLIED BY THE UGHT BOX MANUFACTURER). WIRE FROM THE INTERNAL SWITCH TO THE DRIVERS IN THE LIGHT BOX FRAME, WHICH IS A LISTED WIRE WAY. DRIVERS AND LEDS ARE SUPPLIED AND INSTALLED BY THE LIGHT BOX MANUFACTURER. ALL 120V CONNECTIONS ARE BY THE ELECTRICAL CONTRACTOR. 35. RELOCATED EXISTING BELL/TRANSFORMER. 36. COORDINATE LOCATION AND DEPTH OF J-BOX FOR RECEPTACLES WITH POCKET DOOR FIRE ALARM DEFERRED SUBMITTAL REQUIREMENTS The fire alarm plans provided In this set of drawings is for design intent. The General Contractor shall engage the fire alarm contractor (when required, the Landlord required contractor shall be used) to complete the installation that is compliant with applicable codes. Include submittals to the jurisdiction as required to secure permit and certificate of occupancy. Include all design and jurisdictional fees as required for this work. 4FT X 8FT PHONE BOARD INSTALLED AT 18' AFF TO BOTTOM. ©o BACK OF HOUS CLG. HT.=81-0" —HP-1 A-811,12 208V, 3-PHASE, 35/3 BREAKER JETER 3116, 14.10- 3/4"C STORAGE 21 MCA 116 CLG. HT.=9'-0" CONTACT LENS ROOM I1041 CLG. HT.=9'-0" (1) 1' FOR POWER AND (1) 1' FOR DATA OD RECEPTION/ WAITING AREA 103 CLG. FIT.= 10'-0' MALE RESTROOM CLG. HT.=8'-0" ALCOVE 108 CLG. HT.= B'-0' FEMALE RESTROOM 111 CLG. HT.= 8'-0- HALLWAY #2 I 110 I CLG. HT.= 9'-0' HALLWAY #1 CLG. HT.=9-0" FUTURE PRE -TEST 115 CLG, HT.=8'-0' ERV HEATER B-49,51,53 208V, 3-PHASE, 20/3 BREAKER 012 - 1/2"C 12.5 MCA A EXAM 105 a cL lb) ®E701 PPAS, PPA6, PPA7, PPA8 Q(CLG) RELOCATED CLG. HT.=8'-0' ERV-1 B 39,41 208V, 1 PHASE, 20/2 BREAKER. 3012 - 12"C 42" RP A-13 120V, 20/1 BREAKER 3#12 - 12"C 42' 1 MCA 208V, 1-PHASE, 15/2 BREAKER 3412-12"C 8MCA ► awa 881 11118111110811108111118811 „fmun Ir180111III I` 1 mei (CLG) • BB -I> B-1C 2D V4& PPA9,1Q11 40 ROUTE TO SWITCH "SW3' Ra19-SOYI (CLG) LCO-Sil130 LC1C52il A-41© A-25; P3E,P3F FUTURE PRE -TEST CLG. HT =8'-0' A-40 ROUTE TO SWITCH "SW3' AP1 V(CLG) DLJ(CLG) A-27 P4E,P4F B-7,9 208V, 1-PHASE, 402 BREAKER, 3.8 1 #10 - 3/4 6KW RAME ARMER A-28 A-3D PPD a- WJ1, W12, A-31• 13, W14, , W16 EXAM CLG. HT.=8'-0' A-29 (CLG) ALL GENERAL USE RECEPTACLES MOUNTED BELOW 51-6" A.F.F. SHALL BE TAMPER RESISTANT. ALL OUTLETS TO MATCH FINISH OF ADJACENT SURFACE. UTILIZE LEVITON RENU SYSTEM. PROVIDE CLEAR LABEL WITH BLACK TEXT, 1/4" HIGH, ON ALL SWITCHED OUTLETS. LABEL TO READ "SWITCHED" URGENT CARE LAB B-28 14 ROUTE TO SWITCH "SW3" PRE -TEST --I 109 CLG. HT.=8'-0' (CLG) . 29 (TYP) g-26 e ROUTE TO SWITCH "SW3" ONO (1) 1" FOR POWER AND (1) 1" FOR DATA PP D12 B-13 (CLG) PPC9 B-28 e ROUTE TO SWITCH "SW3" B-30 e ROUTE TO SWITCH "SW3" PPC12 (CLG) B-32 ROUTE TO SWITCH "SW3" RETAIL SALES AREA (1) 1" FOR POWER AND (1) 1" FOR DATA ❑� (CLG) (1) 1"FOR POWER PPD5,6 B-44 14B-34 ROUTE TO SWITCH "SW3" &7A� ROUTE TO SWITCH "SW3' COORDINATION NOTES C01. DO NOT ROUGH IN ANY RECEPTACLES OR DATA OUTLETS ON THE SALES FLOOR WITHOUT FIRST CONFIRMING EXACT LOCATION WITH NEXTORE PROJECT MANAGER. CO2. DO NOT PURCHASE FLOOR BOXES WITHOUT FIRST VERIFYING FINISH (FROM MANUFACTURER'S STANDARD) FOR A PARTICULAR BOX IN A PARTICULAR LOCATION. CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR SHALL REVISE CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA AS WELL AS CIRCUITS THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT. NOTE CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR SHALL REVISE CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA AS WELL AS CIRCUITS THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT. RAY -BAN AREA rig 1,• r �s,�f 2�1W' %' ! 1 G lEII'li:ll: 1. ;i '�0 PPC3 (CLG) (CL e !t!1 111, S I I 111 • SEE DETAIL E007 (TYP.) ROUTE TO SWITCH "SW3" OAKLEY AREA O1C CLG. HT=10'-6" (TYP) 29 B-2 Ste- / ROUTE TO (1) 1" FOR POWER SWITCH "SW3" ROUTE TO SWITCH "SW9- B-3 PPD13,14 PPD15,16 PPD17,18 CL (TYP.1 23 B-25 ROUTE TO SWITCH "SW3' A-42 ROUTE TO SWITCH "SW3" B-36 W` ROUT 0 SWITCH "SW3" (CLG) PPC13 PPC1 14 B-36 ROUTE TO SWITCH "SW3" 118111 m811 111 ummluul mNI B-27 ROUTE TO SWITCH "SW3' 1101111 IIIIIII IIIIIIIIII IIIIIIIII.1 • OR EFRONT HT=12'-7" A-17 14 ROUTE TO SWITCH "SW2" (1) 1" FOR POWER &U9-/on , 8 J, t p9,40y 0 wsryL . h . „1t,/ pt "uHwiS: )fiNLD04G DIV S1Ei: DESIGN ENGINEERING CONSTRUCTION MANAGEMENT: NEXTORE • JUDO Iu61RI Pp. M,M1H4OLC •-Il61p 6540W •6 C=every Mick Fas Get" CT CeC>C. • •I5a1431.9/C0 STORE #79779 SOUTHCENTER MALL SPACE 1/416 SEATTLE, WA 98188 Construction for. Revisions: Mark Date By A 12-18-19 LANDLORD COMMENTS A2-28-20 BALDING DEPARTMENT COMMENTS A 8-14-2020 OWNER COMMENTS A8-27-2020 OWNER COMMENTS A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 DG'IRES 2-03-21 Architect / Engineer Job No.: 029 Nectore Store Design Revision No.: 05 Pluton/ project Numbw 79779 Brand Design Type: LC.05 ISSUED FOR: ID Construction Title ELECTRICAL POWER/SYSTEMS PLAN Date 12-9-19 Drawn By Sheet ELECTRICAL - POWER/SYSTEMS SCALE: W' =1'HY MPR E201 DEMOLITION AND NEW CONSTRUCITON AREA PHASE 3 DEMOLITION AND NEW CONSTRUCTION AREA PHASE 1 i , ...���/alai/////i%/fl//iiii//i%i //Z ////A %% iiiiio///Gala///Gill///xf DEMOLITION AND NEW CONSTRUCTION AREA PHASE 3 CO EU DEMOLITION AND NEW CONSTRUCTION AREA (PHASE 3) EXIT SIGNAGE (TYP) DEMOLITION AND NEW CONSTRUCTION AREA (PHASE 1) . EGRESS PATH dill: i116m .manniormH' I )I II .9 EGRESS PATJ L 1, DEMOLITION AND NEW CONSTRUCTION AREA PHASE 2 DEMOLITION AND NEW CONSTRUCTION AREA (PHASE 2) REFERENCE THE PHASING PLANS CREATED BY THE ARCHITECT FOR MORE SPECIFIC PROJECT INFORMATION. PROVIDE CIRCUITS AS INDICATED ON THE ELECTRICAL PLANS FOR AU. NEW CONSTRUCTION AREAS. WHERE REQUIRED, PROVIDE TEMPORARY AN AND VISUAL DEVICES FOR THE VARIOUS PHASES OF CONSTRUCTION. CONNECT TO EXISTING SYSTEM. USE CEILING DEVICES. SUBMIT TO JURISDICTION FOR APPROVAL. UTILIZE DEVICES COMPATIBLE WITH EXISTING SYSTEM. REUSE DEVICES WHEN THAT OPTION IS AVAILABLE. ALL NOTES AND GENERAL CONTENT FROM THE ELECTRICAL PLANS SHALL APPLY TO THE PHASING CONSTRUCTION AREA AS APPLICABLE. PROVIDE SELF CONTAINED TWO HEADED EMERGENCY BATTERY UNITS FOR EGRESS PATH'S ESTABLISHED BY THE ARCHITECT PHASING PLANS FOR EACH PHASE CONTRACTOR TO DETERMINE AND INSTALL SELF CONTAINED EBU'S AT A SPACING RATE OF ONE EBU PER 10' OF EGRESS PATH, OR TIGHTER AS REQUIRED BY LOCAL CODE OR AS REQUIRED BY THE AHJ. EMERGENCY LIGHTING FOR THE EGRESS PATH FOR FINISHED PHASE AREAS SHALL BE AS SHOWN ON THE ELECTRICAL LIGHTING PLANS. IF REQUIRED BY THE AHJ, PROVIDE ADDITIONAL TEMPORARY EBUS FOR ANY AREAS THAT DO NOT MEET CODE. REMOVE TEMPORARY EBU'S AFTER COMPLETION OF THE PROJECT. PROVIDE A2L/A2LE, G2UG2LE, DBW, TRACK LIGHT FIXTURES, ETC (AS DETERMINED BY THE FIXTURE TYPES USED ON THE ELECTRICAL LIGHTING PLAN) FOR NEW CONSTRUCTION AREAS. FIXTURES TO BE USED AS FINAL INSTALLED FIXTURES AT THE END OF EACH PHASE, IF POSSIBLE. PROVIDE NEW ELECTRICAL PANELS AND TECH RACK AS PART OF PHASE 1 CONSTRUCTION (AS DETERMINED BY THE ELECTRICAL PLANS). � U 9/O? C LT ot?ukwiia eltilLDING D1VIBios DESIGN ENGINEERING CONSTRUCTION MANAGEMENT: NEXTORE • ow -ponce na M Mm OR 4SMO r, (-wrwy Mr*. Feel Granby. CT 06MR • •.Inu) n:res0 -I ONE 431.9700 STORE #79779 SOUTHCENTER MALL SPACE #416 SEAL TLE, WA 98188 Construction for. Revisions: Mark Date By Q12-'8-19 / ' \ 248-20 EVADING DEPARTMENT COMMENTS 8.14.2020 OWNER COMMENTS A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 ORES 21121 Architect / Engineer Job No.: 029 Nextore Store Design Revision No.: 05 NumberNectore ject � 79779 Brand Design Type LC.05 ISSUED FOR: El Construction Title 8/28/20 ELECTRICAL PHASING PLAN Sheet E202 LIGHT FIXTURE SCHEDULE - LENSCRAFTERS INLINE ALLNEW FIXTURES ARE OWNER SUPPUED, ECINSTALLED TAG DESCRIPTION MANUFACTURER MODEL NUMBER FINISH/COLO • VOLTAGE LAMP TYPE LAMP OW FIXTURE WATTS NOTES A2L 2X2 LAPIN, PARABOLIC LENS, RESTICKERED 20W MERCURY 54E-217-OCT-9W-ELB-UNI WHITE 120/277 LED LINEAR; 8W, 3000K, 1300 LUMENS 2 16 A2LE 2X2 LAPIN, PARABOUC LENS, RESTICKERED 20W, 450 LUMEN BATTERY PACK MERCURY 54E-217-OCT-9W.EE&UNI-EMPK/ISL54 WHITE 120/277 LED LINEAR; 8W, 3000K, 1300 LUMENS 2 16 DBW RESTICKERED (20W) INCANDESCENT CAN WITH LED LAMP CONTECH RL38-ICESA (HOUSING); CTR3802-P-W (BLACK BAFFLE, WHITE RING) BLACK 12W 17W 38 DEGREE LED, 3000K 1 17 G2L 2X2 LAYIN, FROSTED LENS, RESTICKERED 20W MERCURY 34E-REG-217-OCT-NFL-UNI WHITE 120/277 LED UNEAR;SW,3000K,1300LUMENS 2 16 G2LE 2X2 LAVIN, FROSTED LENS, RESTICKERED 20W, 650 LUMEN EMERGENCY MERCURY 34E-REG-217-OCT-1FL-ELB-UNI-EMPK/148 WHITE 120/277 LED UNEAR; 8W, 3000K, 1300 LUMENS 2 16 • 2 LAMP, WITH BLACK TRIM BLACK INTERIOR, LED 2 , M2E 2 LAMP, TRIMLESS, BLACK INTERIOR 40W ENGINE, LED DOWNUGHT, 7W EMERGENCYOPTION INTENSE ICL-LEOG2-1.3309-2-BNF-32-EM7 TRIMLISS, BLACK INTERIOR 120 20W LED CHIP PER HEAD, 3000K, 92 CRI 2 40 M3E 2 LAMP, WITH BLACK TRIM, BLACK INTERIOR, LED DOWNLIGHT, EMERGENCY OPTION, 31DEGREE VIABIUUNO MMNITRAFFIC-M3E BLACK 120 16.8W,300LiK,92CR1 2 33.6 El BLACK TRACK HEAD, IS DEGREE OPTICS VIABIZZUNO ECONOTRACK - El BLACK 120 1 20.5 20.5W, 3000K, 92 CRI E2 BLACK TRACK HEAD, 24 DEGREE OPTICS VIABIZZUNO ECONOTRACK - E2 BLACK 120 20.SW, 3000K, 92 CR1 1 20.5 E3 BLACK TRACK HEAD, 31DEGREE OPTICS VIABIZZUNO ECONOTRACK-E3 BLACK 120 205W,3000K,92CRI 1 20.5 T## TRACK, BLACK FINISH, FIELD CUT TO MATCH SIZE ON PLANS, PROVIDE END FEEDS AND CONNECTORS AS REQUIRED VIABIZZUNO ECONOTRACK - T1, T2, T3, T4, T# BLACK 120V N/A X1RW WHITE, SEMI -RECESSED EXTRUDED ALUMINUM LED EDGE UT EXIT SIGN, RED LETTERS, CEILING MOUNTED UGHTALARMS ! r a WHITE 120/277 LED W/UNIT 3 1 CLP4A TRACK CURRENT LIMITER PANEL. THE "W INDICATES THE AMPACITY OF THE CURRENT UMITER. SEE PLANS. ACUITY/SILVER BULLET T24M-1077UL-(4)BP-4A(1)-5A(1)-8A(2)-SM STANDARD 120 N/A RP2 MOW INVERTER UGHTALARMS LMILJ-250 WHITE 120/277 UNE VOLTAGE IN/UNE VOLTAGE OUT 2 CONTROLS COS CEILING OCCUPANCY SENSOR SENSORSWITCH CM-PDT-10 WHITE OS WALLOCCUPANCY SENSOR LUTRON MS-A102-WH WHITE OSD WALLOCCUPANCY SENSOR/DIMMER LUTRON MS-Z101 WHITE D SLIDE DIMMER GREENGATE WBSD-01OSLD-W WHITE NOTES: 1. SEMI RECESSED EDGE UT EXIT SIGN WITH RED LETTERS FOR CEIUNG MOUNTING. WHITE FINISH FOR CANOPY WHERE EXPOSED TO VIEW. RED LED INCLUDED. 2. POWERS FIXTURES IN THE EVENT OF A POWER FAIWRE. SEE WIRING DETAIL GENERAL SUPPUER TO PROVIDE WALL OCCUPANCYSENSORS, DIMMERS, AND/OR COMBINATION SENSORS/DIMMERS. SEE PLANS FOR EXACT QUANTITY. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC- THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS Of THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GENERAL CONTRACTORS COST. BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER Of ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. ELECTRICAL SYMBOLS (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) — XX-## \ HOMERUN TO PANEL AND CIRCUIT INDICATED CIRCUIT OD ® © M TC V �-. i -- -- • RECESSED DOWNLIGHT. DESIGNATIONS VARY - SEE PLANS. ILLUMINATED 'EXIT' SIGN LIGHTING FIXTURE. CEILING MOUNTED OR WFLALLMOUNTED.NTPROVIDE DIRECTIONAL ARROWS AS INDICATED ON WIFI MOTION DETECTOR LIGHTING TIME CLOCK DATA OUTLET: MOUNTED AT 18' AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4' CONDUIT TO ABOVE THE ACCESSIBLE CEILING. SEE ELEVATIONS FOR HEIGHTS. SWITCHED WIRING BRANCH CIRCUIT WIRING / HOMERUN MOTOR DOOR BELL EXTERIOR PUSH BUTTON PANEL — — — — INFLOOR/UNDERFLOOR CONDUIT/WIRE C JUNCTION BOX !c DUPLEX RECEPTACLE -125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE. 20 AMPERE, MOUNTED AT 18' AFF UNLESS OTHERWISE NOTED: '2' INDICATES CIRCUIT NUMBER 'E' EXISTING TO REMAIN WP" INDICATES WEATHERPROOF COVER 'D' DEDICATED CIRCUIT 'GPI' INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE 'R' INDICATES RECESSED (#c DOUBLE DUPLEX RECEPTACLE -125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE MOUNTED AT 18' AFF UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLE - 125 VOLE 2 POLE 3 WIRE, 20 AMPERE MOUNTED `� IN FLOOR BOX. 'CLG' INDICATES MOUNTED IN CEILING : •0u COMBINATION DUPLEX RECEPTACLE AND VOKE/DATA OUTLET T 5 DOOR BELL TRANSFORMER AND SIGNAL •t� •=• I7j _ 11 as MOUNTED IN FLOOR BOX. DOUBLE DUPLEX RECEPTACLE -125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. COMMUNICATIONS FLOOR BOX SWITCH - SINGLE POLE TOGGLE TYPE - 120/277 VOLT. 1-HP RATED, 20 AMPERE, MOUNTED AT 48' AFF UNLESS OTHERWISE NOTED: '3' INDICATES TH REE WAY SWITCH '4' INDICATES FOUR WAY SWITCH 'C' INDICATES SWITCH MOUNTED 8' ABOVE COUNTER 'OS' INDICATES OCCUPANCY SENSOR SWITCH 'Cr INDICATES DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR CTOR 'MS' SWITCH USED AS A MASTER OVER OTHER SWITCHES IN THE ROOM CEILING MOUNTED OCCUPANT SENSOR O Dl SPEAKER SECURITY CAMERA FIRE ALARM DEVICES ARE ONLY SHOWN FOR PREFERENTIAL LOCATION. FINAL LOCATIONS AND QUAN I (TIES SHALL BE DETERMINED BY LL AND ARE ALARM ENGINEER- VERIFY -PRIOR TO ROUGH IN. 0 Di v V D1CLG © CI FIRE ALARM MANUAL PULL STATION MOUNTED AT 48' AFF. FIRE ALARM AUDIO/VISUAL ALARM SIGNAL WALL MOUNTED AT 80' AFF. FIRE ALARM VISUAL ONLY ALARM SIGNAL WALL MOUNTED AT 80' AFF. CLG ARE ALARM VISUAL ONLY ALARM SIGNAL CEILING MOUNTED FIRE ALARM AUDIO/VISUAL ALARM SIGNAL CEILING MOUNTED FIRE ALARM SMOKE DETECTOR FIRE ALARM SMOKE DETECTOR - DUCT MOUNTED IIILIGHT FIXTURE: 'AD' INDICATES FIXTURE TYPE 'a' INDICATES SWITCH a CONTROL. REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION. Ific TRACK AND TRACK MOUNTED LIGHT FIXTURE (DESIGNATIONS VARY - li -- SEE PLANS) DIVISION 16000 - ELECTRICAL PART I - GENERAL A. GENERAL CONDITIONS, CODES & STANDARDS 1. ALL WORK SHOWN ON THE ELECTRICAL DOCUMENTS IS TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. 2. ALL WORK TO MEET APPLICABLE CODES AS LOCALLY ENFORCED. NO WORK ON THE DRAWINGS IS TO BE INSTALLED WHERE IT CONFLICTS WITH LOCAL CODE ENFORCEMENT. COORDINATE WITH THE LOCAL INSPECTOR PRIOR TO INSTALLATION. 3. ELECTRICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTIUTY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL EQUIPMENT AND TOOLS NECESSARY TO COMPLETE THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN. 5. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND RELATED WIRING SHALL BE PROVIDED TO OSHA REQUIREMENTS FOR THE USE OF ALL TRADES DURING CONSTRUCTION. B. SCOPE OF WORK 1. ONLY MAJOR EQUIPMENT IS SHOWN ON THE DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL BID AND CONSTRUCT A COMPLETE AND OPERATIONAL SYSTEM. MISCELLANEOUS EQUIPMENT REQUIRED TO COMPLETE THE WORK IS IN THE ELECTRICAL CONTRACTOR'S SCOPE - ASSUME NO WORK OR EQUIPMENT IS PROVIDED BY OTHERS UNLESS STATED AS SUCH. 2. WRING BIDDING: 2.1. VERIFY THE EXISTING CONDITIONS AND COMPENSATE FOR ANY VARIATIONS IN THE SCOPE AS A RESULT. 2.3. WHERE THERE SA CONFUJCT THAT CANNOT BE RESOLVED BY THE GENERAL CONTRACTOR, ADVISE ENGINEER PROMPTLY FOR A RESOLUTION. DO NOT PROVIDE WORK WHEN THERE IS UNCERTAINTY ON WHAT WORK IS TO BE PERFORMED. 3. AS PART OF THE BIDDING PROCESS, REPORT TO THE TENANT ANY ERRORS OR UNCLEAR DIRECTIONS THAT YOU HAVE IDENTIFIED. C. DOCUMENTS 1. SUBSTITUTIONS 1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A BASE LEVEL OF QUAUTY. THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND MATERIALS EQUIVALENT TO THOSE INDICATED. 2. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS_ D. CONSTRUCTION COORDINATION 1. DURING BIDDING YOU VISITED THE SITE. WORK WITH THE GENERAL CONTRACTOR TO COORDINATE ANY CONFLICTS WITH EXISTING CONDITIONS. THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE TENANT. 2. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE DAMAGE PART 2 - PRODUCTS A WIRING DEVICES 1. DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE NEMA 5-20R RATED FOR 20 AMPS, 125 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. 1.1. SPECIFICATION GRADE DUPLEX RECEPTACLE SHALL BE HUBBELL #5362 SERIES OR APPROVED EQUAL, HEAVY DUTY, WHITE. 1.3. GROUND FAULT CIRCUIT INTERRUPTER PR) DUPLEX RECEPTACLES SHALL BE PROVIDED WHERE INDICATED. 2 SWITCHES SHALL BE TOGGLE OPERATED QUIET TYPE. RATED FOR 20 AMPS, 120/277 VOLTS. WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE PROVIDED WHERE INDICATED. 2.1. SINGLE POLE SWITCHES SHALL BE LEVITON #1221 SERIES OR APPROVED EQUAL SILENT ACIUATING, 20-AMP, 120277V, WHITE. 22 THREE POLE SWITCHES SHALL BE LEVITON #1223 SERIES OR APPROVED EQUAL SILENT ACTUATING, 20-AMP, 120/277V, WHITE 3. DIMMERS SHALL BE LEVITON SLIDING DIMMER SWITCH, OF A RATING, VOLTAGE AND WATTAGE SUITABLE FOR LOAD SERVED. COLORS OF DEVICES AND COVERPLATES SHALL WHITE. 4. COMBINATION WALL DIMMER/OCCUPANT SENSOR SHALL BE LUTRON MAESTRO 0-10V DIMMER WITH INTEGRAL PASSIVE INFRARED OCCUPANT SENSING, AVAILABLE IN 1-WAY OR 3-WAY CONFIGURATIONS. COLOR TO BE WHITE_ VERIFYLOAD SERVED IS COMPATIBLE PRIOR TO ORDERING. S. WIRING DEVICES SHALL BE SPECIFICATION GRADE. 6. COVERPLATES FOR POWER DATA & TELEPHONE SHALL BE LEVITON OR APPROVED EQUAL, WHITE, PLASTIC. 7 UGHTING CONTRACTORS SHALL BE IN NEMA 1 ENCLOSURE. NORMALLY OPEN ELECTRICALLY HELD, 120V, COIL 20A. REFER TO PLANS FOR NUMBER OF POLES. B. LIGHTING AND RECEPTACLE LOAD CENTERS (PANELS) 1. BRANCH CIRCUIT LOAD CENTERS SHALL BE DEAD FRONT TYPE, WITH MAIN LUGS OR MAIN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS NOTED AND AN EQUIPMENT GROUND BAR ALL IN A RUSH MOUNTED SHEET STEEL ENCLOSURE. MINIMUM SHORT CIRCUIT CAPACITY SHALL BE 10,000 AMPS SYMMETRICAL FOR 120/208V, AND 14,000 AMPS SYMMETRICAL FOR 277/480V APPUCATION UNLESS NOTED OTHERWISE. LOAD CENTERS MUST BE SELECTED TO FIT IN A STANDARD STUD WALL. 2. LOAD CENTERS SHALL BE AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, ITE/SIEMENS AND WESTINGHOUSE/CUTLER HAMMER. C. FIXTURES AND LAMPS 1. ALL FIXTURES AND LAMPS ARE FURNISHED BY TENANT, INSTALLED BY ELECTRICAL CONTRACTOR.. D. ARE ALARM SYSTEM I ALL WORK RELATED TO THE FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. OWNER'S REPRESENTATIVE WILL PROVIDE SPECIFICS ON THE SYSTEM. PART 3 - EXECUTION A. GENERAL MISCELLANEOUS t ALL CONDUIT RUN IN FINISHED AREAS SHALL BE CONCEALED. 2. 2. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH BRANCH CIRCUIT IDENTIFICATION FOR BRANCH CIRCUIT PANELBOARDS. PANELBOARDS. FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH NEC 110-16. 3. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR NIGHT LIGHTING, EMERGENCY AND SIMILAR CIRCUITS. 4. ALL FLUSH MOUNTED ;LOADCENTERS SHALL HAVE (3) 3/4' EMPTY CONDUITS INSTALLED TO ABOVE ACCESSIBLE CEILING FOR FUTURE USE. 5. THE FINAL LOCATIONS Of ALL EQUIPMENT, OUTLETS, ETC SHALL BE SUBJECT TO REASONABLE CHANGES IN LOCATION UP TO THE TIME OF ROUGHING -IN, AT NO ADDITIONAL COST TO THE TENANT. B GROUNDING 1. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING CONDUCTOR INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS AND SUPPLEMENTAL AS REQUIRED TO MEET CODE (SUCH AS ARTICLE 517). C. TESTS 1. TEST FOR GROUNDS, SHORT CIRCUITS, AND PROPER FUNCTION OF ALL EQUIPMENT AFTER INSTALLATION IS COMPLETE. FAULTS IN THE INSTALLATION SHALL BE CORRECTED AT NO COST TO THE TENANT. D. DEMOLITION 1. DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT, IF APPLICABLE, SHALL BE PART OF THE ELECTRICAL WORK AS INDICATED ON THE DRAWINGS. GENERAL NOTES A. IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR B. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. C. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. D. EC. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. E LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0' TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0' TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. F. E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY NEXTORE. E.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, EL. SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH NEXTORE. G. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. H. EC. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. I. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS FOLLOWS, UNLESS NOTED OTHERWISE ON PLAN: SWITCHES-48', ELECTRICAL/TELEPHONE/DATA OUTLETS-18', TOP OF PANELBOARDS-6'-6', TIMECLOCKS-5'-0". FOR ALL LENS PROCESSING ROOM OUTLET MOUNTING HEIGHTS SEE EQUIPMENT WIRING SCHEDULE 1. FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIOR LIGHTING FIXTURES, AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 12'-0". K. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING 'AS BUILT' DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO NEXTORE PROJECT MANAGER. L IT IS THE EL.'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM (WITH -IN 10%). M. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND ORDINANCES. N. ALL OUTLETS IN THE LENS PROCESSING ROOM ARE TO BE LABELED WITH PANEL AND CIRCUIT NUMBER. O. THE E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. P. SEE DATA RISER ON THIS SHEET FOR ADDITIONAL INFORMATION. Q PROVIDE POWER, TELEPHONE AND DATA CONDUIT WITHIN FLOOR, BETWEEN FIXTURE AND NEAREST WALL AS INDICATED ON PLANS. METHOD OF CORE DRILLING SHALL BE PER BUILDING REQUIREMENTS. ALL CORE DRILL REQUIREMENTS SHALL BE VERIFIED WITH LANDLORD. CONTRACTOR SHALL SIZE CONDUIT PER NEC PROVIDE FOR X-RAY OF FLOOR WHERE REQUIRED BY THE LANDLORD. CLARIFYE CABLING & NETWORKING QACHECKLIST To be completed by Project Manager on Monday the wine of the [URIFt E Installation *Wei the Icons be labels are sotmnpletedaltrectly, escalate to the arkiNe Feet Renewal Manager Immediately. Task Completed (Y/NI Data Dee Cablmt In the Pieria Robin Confirm the modem Is extended into the DOC (If the Internet servius does not have a modem and Rbjust ,jack, confirm the Jack Is patched over to the DD[I Confirm the modem is labeled as the "CIARIFYE Modem' Confirm theoDC has a 46 port patch panel Installed Confirm these Is a ,wash In the DCC labeled as 'Doctor Switch' Abovethe Dotter Data Cabinet hn the Pn'Teat Room Confirm [ism Meraki wireless rarer mounted to the wall from the floor on the centerline abate the DCC Confirm the Gsm Meraki wireless router Is laded es the'CLANFYE Router' Confirm there h a 6 pat t ete jack 510-from the floor and a' from the centerline or the DOC Confirm there is a power outlet 5'10' from the floor end 8'Iran the centerline of the DOC Confirm Cisco Meraki wireless muter Is online with a solid white status lift Ewen Rooms Confirm the Recessed Esnertamment Box is installed 6' 2' from the floor and 3' 4" from the right hand wall when facing the bail Confirm the cable runs for the wireless access pants retotte correct locations and labeled on the ceiling FILE11Opt, P•rrmttl No. VI 6Y lV� Plan,reinew apprevstis attinect-to errors.aisu ONtlaal0 AppfDV cfd0Astutlton cmcumenis does • tof 8 Jl I brae RIY violation of arw wooled ordinance Reteb' of approved Feb COD! and COn0lIiOn5 ;$ acC.�NNnowledgec. av (&Vt° Data eXp7/26a0 �Y or Tukwila Ptilui'rr.' Il /IC,ON REVISItiNS see:* UlsWda BurIo:n� ,'' , . NOTE: Net/Glens will reau,:, e,4 Dian subnlifal ark '':al' ,nciude a,:.J" . ; ; ..tft review Verdun 3/23/2018 Date Completed: Completed By. Cable Bun Label & Testing Confirmations Cable From Cable 10 e of Runs/face- Nate Location Room Face Plate Labels DCC Patch Panel Labels Confirm all data Conti,lacks firm et cable runt tested successfully IT/NI Seed mnettN on both ends (Y/NJ Pretest 1 DCC Patch Panel 2 P1A-P1B PIA -PIS Purest 1 DOC Patch Panel 2 P1C-PI0 PIC-PID Pretest DOC Patch Panel 2 PIE-PIF PIE -PIT Alcove Or Pretest 2 DX Pala, Panel 2 P2A.P2B P2A-P211 Alcove Or Pretest 2 WC Patch Panel 2 P2C-P20 P2C-P20 Alcove Or Pretest 2 DDC Patch Panel 2 PIE-P2F P2E.P2F Pretest3 DOC Pitch Panel 2 P3A43B P3A4,311 Pretest 3 DOC Patch Pond 2 P3C-P3D P3CP3D Pretest3 DOC Patch Parts 2 P3E.P3F P3E-P3F OD Reception DDC Patch Panel I. RI RI OD Reception DOC Patch Panel 1 112 R2 OD Reception DOC Patch Panel 1 13 R3 Exam Desk DOC Patch Panel 2 ELL&ELI EIA&FIB Earn 1 Recessed floe DOC Patch Panel 1 EX EIC Exert Desk 2 DOC Patch Panel 2 E2A& E2B E2A& E2B Foam 2 Recessed Box DOC Patch Panel 1 EX EX Exam Desk 3 DOC Patch Panel 2 63A & E3B E3A& E3B Earn 3 Recessed Boa DOC Path Panel 1 EX DC Wheless Access Point I DOC Path Panel 1 API API Wireless Ayes Poet 2 DOC Patch Panel 1 AP2 AU S.Po,t Data lads Above DOC DOC Patch Panel I 1 1 &Pbrt Data late Above DOC MC Patch Panel 1 2 2 6-Pet Data lack Above DOC DOC Path Panel 1 3 3 6-Post Data **Above DOC 00C Patch Panel 1 4 4 6-POrt Data Jack Above 00C WC Patch Panel 1 5 5 6-Part beta lark Above PDC 00C Petal Pend 2 6 6 tertsCra*ers Backboard DOC Patch Panel 1 CM CM lensCrafters Bactboard DOC Patrlspand 1 8B 88 [LABIFYE CHECKLIST REV 0.0.iesx ISEPARATE PERMIT REg/iULRED FOR: LQ MechsrfiCB! cjii Electrical (Plumbing 13 Gas Piping City of Tukwila F B_ UILSDING DIVISION Page 1 al 1 FLOOR FINISH (##). BOXES • BLACK 0 GRAY ® ALUMINUM • BRASS AS REFERENCED ON THE PLAN SHEETS RECESSED FURNITURE FLOOR O SYSTEMONE FLOOR BOX HUBBELL CFBS1R4PFB W/CUP CD SYSTEMONE FLOOR BOX HUBBELL S1PFB SUB PLATES • SYSTEMONE SUB -PLATE S1 R4SP2X2DUPLEX O SYSTEMONE SUB -PLATE HUBBELL S1SPFF## COVER/ FLANGE ® CF8S1R4CVR## (CARPET) %---- ..-- POKE THRU FITTINGS FINISH (##): ® ALUMINUM 0 BRASS 0 BLACK 0 GRAY AS REFERENCED ON THE PLAN SHEETS RECESSED FURNITURE POKE THRU FITTING WIREMOLD EVOLUTION 6AT SERIES POKE THRU SIPTFIT THRU POKE SUB PLATES CD TWO DUPLEX RECEPTACLES AND UP TO FOUR DATA OUTLETS O SYSTEMONE SUB -PLATE HUBBELL SISPFF## COVER / FLANGE 0 6CTC2##(CARPET)/ 6CT2## (TILE) E008 LC ST1.0 FLOOR BOX / POKE THRU SCHEDULE 01-1 1 Rv 1VA U E1) PEG (,TEfl REPv,hriN OL CITY OF MAR 05 I?AiLA t COMPLIANCES— NFPA 770 - R'ISC APR2 " 2 2 Atof Tu ! BUILDING DIVISION 7 PERMIT CENTER ELP1 1067 DESIGN ENGINEERING CONSTRUCTION MANAGEMENT: NEXTORE •SIC.:u.etlu%ee, Man;ts 5= • .1499I a5-60)1 • F Gean.y&al Oat Gravy. CT Pas •,t 1ar4 Aa STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Constructionfor: sr I j-O II O r17 vp LlaO e x0 < J ,c \\\\ice a) Oa CA to Po -0 7 z 9 Les g LLJ J Revisions: Mark Date46. (sv 12-18.19 LANDLORD COMMENtS Q 2.2B-20 BALDING DEPARTMENT COMMENTS A 0 Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 EWRES MCOPI Architect / Engineer Job No.: 029 Nextore Store Design Revision No.; 05 �erproject 79779 Brand Design Type LC.05 ISSUED FOIL• ® Construction Title ELECTRICAL GENERAL NOTES & DETAILS Date 12-9-19 Drawn By STAFF Checked By MPR Sheet E001 INSIDE TECH RACK OR AT PHONE BOARD - SEE PLANS Ifb 65 MONITOR CAMERA (QUANTITY ON PLAN) QUADRUPLEX RECEPTACLE 1. EXTEND CABLE TO PROPOSED HEAD END EQUIPMENT LOCATION. PROVIDE ENOUGH EXCESS CABLE TO REACH ANY WALL IN BACK ROOM. COIL AND MARK CABLE AS CCTV. HEAD END EQUIPMENT LOCATION MUST BE WITHIN 10' OF THE 'NETWORK SWITCH ACCESS'. 2. FOR CAMERAS, PROVIDE WHITE PLENUM RATED CAT 6 CABLING. COIL 15' OF CABLING AT EACH CAMERA LOCATION FOR CONNECTIONS. 3. PROVIDE RI-45 CONNECTORS AT CAMERA LOCATIONS ONLY. CONNECTORS NOT NEEDED AT THE HEAD END EQUIPMENT LOCATION. E005 CCTV SYSTEM RISER E010 M ICROWAV FRIDGE PLAN VIEW 9 I MICRO 0 0 FRIDGE — 1„_ 2 OUTLETS WITH (4) USB PORTS - HUBBELL USB1SX2W 24'W X 8- D SHELF MICROWAVE AND FRIDGE FURNISHED AND INSTALLED BY TENANT. DUPLEX OUTLET ON DEDICATED 20A CIRCUIT ELEVATION MICROWAVE, REFRIGERATOR, USB ELEVATION EMERGENCY UGHTING INVERTER. LINE VOLTAGE IN, LINE VOLTAGE OUT 277V IN 120V IN HOT I SWITCHED 120V AC HOT I SWITCHED AREA LIGHT SWITCH, OCCUPANT SENSOR. ETC. NEUTRAL GROUND COMMON IN GND E004 IOKC-00422-00_CUSTOM WALL UNIT OKC-00422-00_CUSTOM WALL UNIT COMMON OUT 120V IN 277V IN ON IOFF ON IOFF 120V AC, SWITCHED NEUTRAL i • AREA EMERGENCY LIGHT FIXTURES. AREA NON -EMERGENCY LIGHT FIXTURES. EMERGENCY LIGHTING WIRING SCHEMATIC - WHEN INVERTER IS APPLIED 1E0041> LC-05832-00 BACKWRAP CABINET OD AREA /--1' BIZ"---- 2' 7` / 3' 72'� • r 2' li t .1. r J•I• 05832-00 LC-05832-00 BACKWRAP CABINET OD AREA CONNECT TO NEAREST 120V, CONVENIENCE RECEPTACLE CIRCUIT. N 120V TO 24V SYSTEM TRANSFORMER IN NEMA 1 ENCLOSURE. EDWARDS 4592 E006 OKS-00411-00 WALL UNIT 54" OK5-00216-00 _ 54" LIGHTBOX WITH GRAPHIC 00216-00 OKS-00216-00 _ 54" LIGHTBOX W/GRAPHIC ' ENGINEER NOTE: THERE MAY BE A IGHTBOX H RE REQUIRING A RECEPTACLE. ICI 00411-00 2' 3"—/ U OKS-00411-00 WALL UNIT 54" NON -SALES BUZZER (ABOVE REAR DOOR) EDWARDS 4340-4G5- 24VAC PUSHBUTTON, EDWARDS 4852 24V, SYSTEM SALES BUZZER AT CASH WRAP EDWARDS 4340-4G5- 24VAC DOOR ENTRY BELL SYSTEM RISER l I OKS-00201-00 OAKLEY SIGN HORIZONTAL SIGN IS INSTALLED IN BACKWRAP AND POWER IS SUPPLIED FROM BEHIND BACKWRAP. E007 CO) ®L®C a.OW 00201-00 OKS-00201-00 _ OAKLEY SIGN HORIZONTAL 05803-00 LC-05803-00 CASH DESK RIGHT TAG EQUIPMENT FURNISH BY: INSTALLED BY: Q WALL SHELF VENDOR VENDOR © AMPLIFIER VENDOR VENDOR © SPEAKER WIRE VENDOR VENDOR Q SPEAKER VENDOR VENDOR © SPEAKER BAFFLE VENDOR VENDOR SOUND SYSTEM RISER e LABEL SW1 e LABEL SW2 e LABEL SW3 e e LABEL SW4 e LABEL SW5 LC-05821-00 BACKWRAP CABINET 4X55" 24/7 1 05821-00 O 24/7 1 aLC-05806-00_OD RETAIL CASHDESK LEFT LC-05806-00 OD RETAIL CASHDESK LEFT LC-05821-00 BACKWRAP CABINET 4X55" e LABEL 5W6 LABEL SW7 LABEL TO BE PRINTED (WITH A LABEL MAKER), BLACK INK ON CLEAR B' - 'OU. e E •B - XT SC COIL ' v TION EQUIPMENT CONTROLLED SALES FLOOR CABINET UGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET LIGHTING SALES FLOOR CABINET EQUIPMENT CONTROLLED SALES FLOOR CABINET LIGHTBOX LIGHTBOX UGH TBOX LIGHTBOX FUTURE FUTURE FUTURE [COIL 8-POLE SQUARE-D LIGHTING CONTACTOR ELECTRICALLY HELD CONTACTOR "8" COIL 8-POLE SQUARE-0 LIGHTING CONTACTOR ELECTRICALLY HELD CONTACTOR C CIRCUIT 8 24 13 26 B-28 8-30 8 32 8 34 836 82 CIRCUIT 84 8 22 A-40 A42 B 25 m LABEL SWB z\ LABEL SW9 DIGITAL TIMER SWITCH FOR COIL BYPASS. SET TIMER TO 2 HOURS. SWITCH ALLOWS STORE OCCUPANTS TO BYPASS THE TIMED SCHEDULE FOR A SET TIME PERIOD. LOAD DESCRIPTION STOREFRONT LIGHTING STOREFRONT RECEPTACLES SALES PERIMETER OUTLETS SALES TRACK SALES TRACK SALES TRACK SALES TRACK SALES AMBIENT STORE EXTERIOR SIGN SWITCH # 1 B 4 LC-05821-00 BACKWRAP CABINET 4X55" SIGN POWER CIRCUIT: SEE PANEL SCHEDULE COIL CIRCUIT RELOCATED TIMECLOCK 2 CHANNEL ASTRONOMIC CHANNEL 1 6 7 8 10-POLE SQUARE-D LIGHTING CONTACTOR ELECTRICALLY HELD CONTACTOR' A' 9 SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS CHANNEL 2 ROUTE THROUGH SWITCHING FOR INDEPENDENT, SECONDARY CONTROL SEE MASTER SWITCHING DETAIL CONTACTOR TO BE SQUARED OR EQUAL, 20A CONTACTS, ELECTRICALLY HELD IN NEMAT ENCLOSURE. INSTALL ABOVE CEILING (WHEN A CEILING IS PRESENT) WHERE PERMITTED BY CODE REVIEWED FOjV 1 I COMPLIANCE HI I NFPA70-NEC ' 2 ' 202i; I CIty of Tukwila 1 UUILDING DIVISION I RECFilVED CITY OF -i KWILA MAR 05 711711 PERMIT CENTER D[SIGN FN3MFFRING-ONSTR: C➢CAN MANAGEMENT NEXTORE . -410C taco rate. MW{ M�EPA •-I,i:3. asS � 6Orrery aau. Eat at, L' %..: ri .1 :ac: a'»ar STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Construction for: Revisions: Mark Date By A 12-18-19 EANCtORD COMMENTS BUILDING DEPAMTMENTCOMMENTS A A A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 Architect / Engineer Job No.: 029 Nextore Store Design Revision No.: 05 Nextore project Number 79779 &and Design Type LC.05 ISSUED FOR: ® Construction lode ELECTRICAL DETAILS Date 12-9-19 Drawn By Sheet E001 SWITCH BANK AND ASSOCIATED CONTACTORS, PHOTOSWITCH WHEN EXTERIOR CONTROL IS REQUIRED ET1 STAFF Checked By MPR E002 DESIGN ENGINEERING CGNSTRUCION MANAGEMENT WIRING BETWEEN EACH SECTION CONSUMES 150W r_LorAT 120V, FOR A 2.5 PP SYSTEM. ry_ 1 ' MODULES IS PROVIDED AND INSTALLED BY THE LED WALL VENDOR. / / 7 1/ /. I1 / l /t \1 l t 3' I I I rr 1 1Thk 4 I i'-'2" Si. I 1 -72 I i r (2) CAT6 TO PATCH PANEL AT PHONE BOARD (2) CAT6 TO PATCH PANEL AT PHONE BOARD Th 3' TWO RECEPTACLES ARE CONNECTED TO ONE CIRCUIT. PANEL LOAD CALCULATE AT 1200 VA PER CIRCUIT. 2 CIRCUITS REQUIRED. E020 4X4 LED WALL E020 EC TO ROUTE MC CABLE TO BUILT IN SWITCH IN FRAME OF LIGHT BOX AND CONNECT. THEN EC TO ROUTE WIRING IN FRAME (A USTED RACEWAY) TO DRIVERS AND CONNECT. DRIVER BY FIXTURE SUPPLIER SWITCH BY FIXTURE SUPPLIER E050 LIGHTBOX ELECTRICAL INFORMATION IE050Y A ifea 3'-8" i COOS E101 OPTICAL STATION E101 ELECTRICAL INFORMATION IRB-02408-00 _ WALL UNIT 3 COLUMNS HIGH CAPACITY ' RB-02701-01 _ LENS TABLE ORMAII 02408-00 Pala 02701-01 ' RB-02406-00 _ WALL UNIT 4 COLUMNS HIGH CAPACITY 02406-00 RB-02408-00 _ WALL UNIT 3 COLUMNS HIGH CAPACITY RB-02701-01 LENS TABLE RB-02406-00 _ WALL UNIT 4 COLUMNS HIGH CAPACITY IRB-02323-00 SOHO TABLE ' RB-02300-00 _ GOGO DISPLAY ' RB-02211-00 _ BACKLIT METAL LOGO 02323-00 02300-00 1=1 t J power supply from the wall 02211-00 RB-02323-00 SOHO TABLE RB-02300-00 GOGO DISPLAY RB-02211-00 _ BACKLIT METAL LOGO 13" 41" GA CONNECTION FOR TANKLESS WATER HEATER (IF USED) E103 CONTACT LENS E103 N ELECTRICAL INFORMATION CONNECTION FOR TANKLESS WATER HEATER (IF USED) • O FI 41' 13" GFI E104 CONTACT LENS E104 ELECTRICAL INFORMATION OUTUNE OF LOW PROFILE LEVITON 47617-REB, WHITE FINISH, RECESSED ENTERTAINMENT BOX. 1 1/2' CONDUIT ROUTED J CONCEALED FROM ENTERTAINMENT BOX TO JUNCTION BOX AT EXAM DESK. PROVIDE PULL STRING. 3'-4" DIMENSION IS TO EDGE OF BOX. ELEVATION ix* 4p EQ11t __1"._—r m D EQ108 PLAN EQ109B VERIFY INSTALLATION OF DEVICES WITH GC PRIOR TO ROUGH IN. DEVICES ARE TO BE ACCESSIBLE - DO NOT INSTALL BEHIND DOORS OR ALE CABINETS. r-----i m at. ELEVATION Nis - IN• • SE-0D03 SE-0D03 WALL JACK FOR PHONE INSTALLATION. SE-C)b01 L 1/2" CONDUIT ROUTED ELEVATION CONCEALED FROM ENTERTAINMENT BOX TO JUNCTION BOX AT EXAM DESK. PROVIDE PULL STRING. 4Val_Q _SE- SE-0D03 EQ100A EQ6A SE-OD01 OPTOS PLAN PLAN SE-OD01 DOCTOR'S DESK VERIFY INSTALLATION OF DEVICES WITH GC PRIOR TO ROUGH IN. DEVICES ARE TO BE ACCESSIBLE - DO NOT INSTALL BEHIND DOORS OR FILE CABINETS. WALL JACK FOR PHONE INSTALLATION 07- B 11-$. Ds 1 1/2' CONDUIT ROUTED CONCEALED FROM ENTERTAINMENT BOX TO JUNCTION BOX AT EXAM DESK. PROVIDE PULL STRING. REFRACTION ROOM EQUIPMENT Ellf-la 7 OUTLINE OF LOW PROFILE LEVITON 47617-RED, WHITE FINISH, RECESSED ENTERTAINMENT BOX. 1 1/2' CONDUIT ROUTED CONCEALED FROM ENTERTAINMENT BOX TO JUNCTION BOX AT EXAM DESK. PROVIDE PULL STRING. INMPI 1e'+'CE tar 'RD . Nee TuKwiIB �- BUILLhRVG DIVISION -I EQ108 PLAN Co n 1' 4" DIMENSION IS 10 EDGE OF BOX, io ELEVATION AR 24- Jr RECEIVED CITY OF "1 UI:MLA MAR 0 5 Imo EQ10�[ERMIT CENTER LC001 REFRACTION (EXAM) ROOM ELECTRICAL INFORMATION NEXTORE •4t.00.raINticeuser 0,4,E •.1353,TS-66Co •6crtrnYlkOME Karl/ CT 06026 •.1 .'W.j 4.3192:0 STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Construction for W -J Revisions: Mark Date A 12-18-V BY IANMURE COMMENTS A2-2a- o WADING NG DEPMIMENTCOMMENIS A A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 EXPIRES *0121 Architect / Engineer Job No.: 029 Nextore Store Design Revision No.: 05 Nextore project Number 79779 Band Design Type: LC.05 ISSUED FOR: ® Construction Title ELECTRICAL DETAILS Date 12-9-19 Drawn By STAFF Checked By MPR Sheet E003 v PATCH PANEL "PPA" - 24 PORT (LOCATED AT PHONE BACK BOARD) POS LABEL DESCRIPTION )OS LABEL DESCRIPTION ?OS LABEL DESCRIPTION ?OS LABEL 1 PPA1 WORK COUNTER 7 PPA7 WORK COUNTER 13 PPA13 EXAM ROOM #1 - WALL PHONE 19 PPA1 SPACE 2 PPA2 WORK COUNTER 8 PPAB WORK COUNTER 14 PPA14 EXAM ROOM #1 20 PPA2 SPACE 3 PPA3 WORK COUNTER 9 PPA9 RECEPTION DESK 15 PPAIS EXAM ROOM #2 - WALL PHONE 21 PPA2 )4\ SPACE 4 PPA4 WORK COUNTER 10 PPA1O RECEPTION DESK 16 PPA16 EXAM ROOM #2 22 PPA2 SP CE 5 PPAS WORK COUNTER 11 PPA11 17 PPA17 SPACE 23 PPA23 (iA{KGf11l�A 6 PPA6 WORK COUNTER 12 PPA12 SP CE.�� 18 PPA18 SPACE 24 PPA24 RECEPTION BACKWRAP ROUTE IN CATEGORY CONDUIT OR 6 CABLING FROM IN FREE AIR AS EACH PORT PER THE JURISDICTION ON THE PA PANEL TO THE CORRESPONDING REQUIREMENTS WHERE WIRING IS JACK IDENTIFIED ON THE PLAN. ROUTE ROUTED IN FREE AIR PROVIDE 1-HOOKS AT EFT THE INTERVALS WIRING IN A CODE COMPLIANT FASHION, MAXIMUM AND NEATLY INSTALL. v PATCH PANEL "PPB" - 24 PORT (LOCATED AT PHONE BACK BOARD) PUs LABEL DESCRIPTION "11S LABEL DESCRIPTION ?OS LABEL OESCRIP)ION 'OS LABEL DESCRIPTION 1 PP81 SPACE 7 PPB7 SPACE 13 PP813 CONTACT LENS 19 PPB19 SPACE 2 PPB2 SPACE 8 PPBB SPACE 14 PP1314 CONTACT LENS 20 PPB20 SPACE 3 PPB3 SPACE 9 PPB9 TRAFFIC COUNTER 15 PPB15 SPACE 21 PPB21 SPACE 4 PPB4 FLOOR DISPLAY CASE 10 PP810/ WIRELESS ACCESS POINT 16 PP1316 SPACE 22 PPB22 SPACE 5 PP85 FLOOR DISPLAY CASE 11 PPB11 SPACE 17 PPB17 SPACE 23 PPB23 SPACE 6 PPB6 FLOOR DISPLAY CASE 12 PPB12 SPACE 18 PPB18 SPACE 24 PPB24 SPACE ROUTE IN CATEGORY CONDUIT OR 6 CABLING FROM IN FREE AIR AS EACH PORT PER THE JURISDICTION ON THE REQUIREMENTS. PATCH PANEL TO THE CORRESPONDING WHERE WIRING IS ROUTED JACK IN DENTIFIED ON THE PLAN. ROUTE FREE AIR PROVIDE 1-HOOKS AT 6FT THE INTERVALS WIRING IN A CODE COMPLIANT FASHION. MAXIMUM AND NEATLY INSTALL V PATCH PANEL "PPC" - 24 PORT (LOCATED AT PHONE BACK BOARD) POS LABEL DESCRIPI ION -OS LABEL DESCRIPTION 'OS LABEL DESCRIPTION ''OS LABEL DESCRIPTION 1 PPC1 IP SURVEILLANCE CAMERA 7 PPC7 IP SURVEILLANCE CAMERA 13 PPC13 IP SURVEILLANCE CAMERA 19 PPC19 SPACE 2 PPC2 IP SURVEILLANCE CAMERA 8 PPCR IP SURVEILLANCE CAMERA 14 PPC14 SPACE _ 20 PPC20 SPACE 3 PPC3 IP SURVEILLANCE CAMERA 9 PPC9 IP SURVEILLANCE CAMERA 15 PPC15 SPACE 21 PPC2I SPACE 4 PPC4 IP SURVEILLANCE CAMERA 10 PPC10 IP SURVEILLANCE CAMERA 16 PPC16 SPACE 22 PPC22 SPACE S PPCS IP SURVEILLANCE CAMERA 11 PPC11 IP SURVEILLANCE CAMERA 17 PPC17 SPACE _ 23 PPC23 SPACE 6 PPC6 IP SURVEILLANCE CAMERA 12 PPC12 IP SURVEILLANCE CAMERA 18 PPC18 SPACE 124 PPC24 SPACE ROUTE CATEGORY 6 CABLING FROM EACH PORT ON THE PATCH PANEL TO THE CORRESPONDING IN CONDUIT OR IN FREE AIR AS PER THE JURISDICTION REQUIREMENTS. WHERE WIRING IS ROUTED JACK IDENTIFIED ON THE PLAN. ROUTE THE WIRING IN A CODE COMPLIANT FASHION, IN FREE AIR PROVIDE 1-HOOKS AT 6FT INTERVALS MAXIMUM AND NEATLY INSTALL V PATCH PANEL "PPD" - 32 PORT (LOCATED AT PHONE BACK BOARD) POS LABE(, DESCRIPTION '91 LABEL DESCRIPTION ?OS LABFUyBESERIPFIftN-��� S IABH T1eNr . I PPD1 PERIMETER DISPLAY CASE S� PPD9 SALTS BACKWRAP 17 PPD17 PERIMETER DISPLAY CASE 25 PPD2S SALES AREA CASH DESK 2 2 PPD2 PERIMETER DISPLAY CASE 10 PPD10 SPACE 18 PPD1 PE M R D SP( l�Y CASE 26 PPD2F( SALES AREA CASH DESK 3 PPD3 PERIMETER DISPLAY CASE 11 PPD11 SALES AREA LED WALL 19 PPD19 L L W 27 PPD2* SALES AREA CASH DESK 4 PPD4 PERIMETER DISPLAY CASE 12 PPD12 SALES AREA LED WALL 20 PP020 jAr¢S:4�IF 28 PPD2 SALES AREA CASH DESK 5 PPDS SPACE 13 PPD13 SALES AREA LED WALL 21 PP021 SALES AREA CASH DESK 29 PPD29 �"�-'"~ 6 PPD6 SPACE 14 PPD14 SALES AREA LED WALL 22 PPD SALES AREA CASH DESK 2 30 PPD30 LAB 7 PPD7 SPACE 15 PPD15 SALES AREA LED WALL 23 PPD SALES AREA CASH DESK 31 PPD31 LAB 8 PPDB SALES BACKWRAP 16 PP016 Sal ES AREA LED WALL 24 PPD2 5 CASH DE K 32 PPD32 LAB ROUTE CATEGORY 6 CABLING FROM EACH PORT ON THE PATCH PANEL TO THE CORRESPONDING JACK I N LED ON HE . ROUTE THE WIRING IN A CODE COMPLIANT FASHION, IN CONDUIT OR IN FREE AIR AS PER THE JURISDICTION REQUIREMENTS WHERE WIRING IS ROUTED IN FREE AIR. PROVIDE 1-HOOKS AT 6FT INTERVALS MAXIMUM AND NEATLY INSTALL L0002 NETWORK DIAGRAM LENSC RAFTERS EQUIPMENT FURNISHED INSTALLED DATA/TECH RACK EC EC DATA WIRING EC EC PATCH PANELS EC EC DATA JACKS EC EC TRAFFIC COUNTER VENDOR VENDOR DATA WIRING EC EC SURVEILLANCE CAMERA VENDOR VENDOR DATA WIRING EC EC SOUND SYSTEM VENDOR VENDOR RECEPTACLES IUNSWITCHED) EC EC HEAD END EQUIPMENT VENDOR VENDOR SPEAKER WIRING (ACT CEIUNG) VENDOR VENDOR SPEAKER WIRING (GYPCEIUNG) VENDOR VENDOR RACEWAY SYSTEM TO SPEAKERS WHEN A GYP CEIUNG IS INSTALLED. PROVIDE PULL WIRE EC EC SPEAKER VENDOR VENDOR LED WALLS RECEPTACLES(UNSWITCHED) EC EC DATA OUTLETS, TERMINATED AND TESTED EC EC DATA WIRING BACK TO PATCH PANEL EC EC POWER WIRING BETWEEN COMPONENTS VENDOR VENDOR DATA WIRING BETWEEN COMPONENTS VENDOR VENDOR MEDIA PLAYER VENDOR VENDOR MEDIA PLAYER SHELF EC EC PROGRAMMING VENDOR VENDOR TELEPHONE BACKBOARD EC EC CONDUIT FROM LL ROOM TO TENANT SPACE EC/LL PER LEASE EC/LL PER LEASE WIRING FROM THE LL ROOM TO THE TENANT SPACE EC EC PLYWOOD BACKBOARD EC EC BACKWRAP EQUIPMENT D-UNK SWITCH VENDOR VENDOR EQUIPMENT SPECIFICATIONS CATEGORY 6 CABLE: GENERAL CABLE 7141849 PLENUM RATED, BLUE JACKET EC EC LC AND LCM ONLY: CATEGORY 6 MODULAR JACK (WHITE): PANDUITCJ6X88TGW EC EC 24 PORT PATCH PANELS: PANDUIT DP246X88TGY EC EC 48 PORT PATCH PANELS: PANDUIT DP486X88TGY EC EC EQUIPMENT RACKS EC EC WALL MOUNTED RACK: MIDDLE ATLANTIC WM-15-18 (30"H X 20"W - 15RU) EC EC 1U VENTED SHELF: MIDDLE ATLANTIC U1V 1SP VENTED SHELF EC EC 2U VENTED SHELF: MIDDLE ATLANTIC U2V 2SP Vented Shelf EC EC HORIZONTAL CABLE MANAGEMENT: PANDUITWMPFSE EC EC VERTICAL WIRE MANAGEMENT: LEVITON 49404VFR EC EC WIRING FROM LL TELEPHONE ROOM TO SPACE: 25 PAIR, CATEGORY Se, PLENUM EC EC GenSPEED' 5000 Category Se 25-Pair Backbone Cable, Grey D-LINK ATTHE BACKWRAP: VENDOR VENDOR FACEPLATES EC EC TESTING AND REPORTS TESTING OF DATA AND VOICE OUTLETSAND WIRING EC EC PDF REPORT SHOWING COMPLIANCE WITH CATEGORY 6 STANDARD EC EC PDF REPORT TO SHOW OUTLET LOCATION AND TESTING RESULTS EC EC LENSCRAFTERS INUNE ONLY - DOCTOR'S DATA CABINET (DDC) PHYSICAL CABINET NEXTORE GC PATCH PANELS EC EC WIRING FROM PHONE BOARD TO PATCH PANELS EC EC AU. STATION CABUNG EC EC MAIN PHONE BOARD DIGITAL EQUIPMENT MIRAKI ROUTER VENDOR VENDOR 66 BLOCK OR BISQUITJACK UTTUTY UTILITY CONNECTION BETWEEN THE 66 BLOCK AND PATCH PANEL VENDOR VENDOR ANY ROUTERS OR SWITCHES VENDOR VENDOR PATCH CABLES BETWEEN PATCH PANELS AND ELECTRONICS VENDOR VENDOR ANY PATCH CABLES VENDOR VENDOR (2) CAT6 TERMINATE TO DDC 48 `PORT PATCH PANEL NOTES: 1. ALL WORK SHOWN ON THIS DRAWING IS BY THE ELECTRICAL CONTRACTOR. THE ONLY EXCEPTION IS THE DOCTORS DATA CABINET WILL BE SUPPLIED BY THE TENANT. 2 PLENUM RATED 4 PAIR CAT6 CABLE TO BE BERK-TEK LANMARK-1000; RATED CMP FOR PLENUM &OSP WHERE USED BELOW SLAB 3. HOME RUN CABLE TO BACKBOARD 3.1. LABEL TERMINATE AND TEST IN PATCH PANEL 32. CONTINUOUS RUN -NO SPLICES 4. SEE ELECTRICAL/ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 5. EACH COMPUTER (#21) OR FUTURE COMPUTER OR ACCUFIT AT A FITTING COUNTER REQUIRES A HOME RUN CAT6 CABLE TO THE BACKBOARD PATCH PANELS. 6. ROUGH IN TO BE A 4 X 4 BOX WITH SINGLE DEVICE PIASTER RING IN WALL AS PER ARCHITECTURAL DRAWINGS WITH MINIMUM 3/4" CONDUIT TO 6' ABOVE CEILING. DEDICATED CIRCUIT FOR WIRELESS ROUTER QUAD FOR POWER STRIPS MUSIC - EQUIPMENT BY AND (SERVICE BY OTHERS) - SEE E007 COMPUTER POWER STRIP (BY TENANT SERVER VENDOR) OPEN RACK SEE DETAIL DEMARC PHONE PATCH PANEL ASSUMING MINIMUM POINT OF ENTRY DEMARC AND CROSS CONNECT PHONE POWER STRIP (BY PHONE VENDOR) INSTALL AT&T MANAGED INTERNET CIRCUIT AT PHONEBOARD LONG X 4" DIA PVC TUBE FOR AS BUILT PLANS (BY GC) 4 X 8 PHONE/EYENET BACK BOARD (MOUNTED VERTICAL BY GC) BUSHINGS /PHONE CONDUIT CEILING LENSCRAFTERS NETWORK PATCH PANEL "DDC" - 48 PORT (LOCATED IN PRETEST ROOM) PDS- LABEL DESCRIPTION 70S LABEL DESCRIPTION ?OS LABEL DESCRIPTION SOS LABEL DESCRIP RON 1 WJ1 DDC 6-PORT DATA JACK 13 PIE PRETEST ROOM #1 25 P3E PRETEST ROOM #3 37 ETA EXAM ROOM #1 2 WJ2 DDC 6-PORT DATA JACK 14 PIF PRETEST ROOM #1 26 NE PRETEST ROOM #3 38 E1B EXAM ROOM #1 3 W13 DOC 6-PORT DATA JACK 15 P2A PREM.] ROOM #2 27 P4A PRETEST ROOM #4 39 EIC EXAM ROOM #1 4 WJ4 DDC 6-PORT DATA JACK 16 P28 PRETEST ROOM #2 28 P4B PRETEST ROOM #4 40 E2A EXAM ROOM #2 5 WJ5 DDC 6-PORT DATA JACK 17 P2C PRETEST ROOM #2 29 P4C PRETEST ROOM #4 41 E2B EXAM ROOM #2 6 Wi6 DDC 6-PORT DATA JACK 18 P2D PRETEST ROOM #2 30 P4D PRETEST ROOM #4 42 E2C EXAM ROOM #2 7 API CEILING ACCESS POINT 18 P2E PRETEST ROOM #2 31 P4E PRETEST ROOM #4 43 mix SPACE 8 AP2 CEILING ACCESS POINT 20 P2F PRETEST ROOM #2 32 P4F PRETEST ROOM #4 44 lax SPACE 9 P1A PRETEST ROOM #1 21 P3A PRETEST ROOM #3 33 Ink SPACE 45 nit SPACE 10 P18 PRETEST ROOM #1 22 P3B PRETEST ROOM #3 34 Loa SPACE 46 R1 RECEPTION DESK 11 P1C PRETEST ROOM #1 23 P3C PRETEST ROOM #3 35 ro SPACE 47 R2 RECEPTION DESK 12 RID PRETEST ROOM #1 24 ND PRETEST ROOM #3 36 xxx SPACE 48 R3 RECEPTION DESK ROUTE CATEGORY 6 CABUNG FROM EACH PORT ON THE PATCH PANEL TO THE CORRESPONDING JACK IDENTIFIED ON THE PLAN. ROUTE THE WIRING IN CONDUIT OR IN FREE AIR AS PER THE JURISDICTION REQUIREMENTS. WHERE WIRING IS ROUTED IN FREE AIR PROVIDE J-HOOKS AT 6FT INTERVALS IN A CODE COMPLIANT FASHION, MAXIMUM AND NEATLY INSTALL MEWRAKI ROUTER MOUNTED TO WALL ABOVE IPAD CHARGING CABINET, PROVIDED AND INSTALLED BY CLARIFYE DATA INSTALL TEAM IPAD CHARGING CABINET PROVIDED AND INSTALLED BY CLARFFYE DATA INSTALL TEAM CKT #2 WJ1, W12, W13, WJ4, �6W16 CKI #1 1 1/4 '9 DRYWALL RING FOR NETWORK CABLING. ALL CLARIFYE NETWORK CABLES TO BE ROUTED TO THIS LOCATION. 10" s 0 in BOH-DDC 48-PORT CAT6 PATCH PANEL SUPPUED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. PROVIDE 2RU WALL MOUNTING BRACKET FOR PATCH PANEL CLARIFYE 8-PORT MANAGED ETHERNET SWITCH 2 GANG DRYWALL RING. FIELD LOCATE IN NON DEMISING WALL BEHIND DDC. DOCTOR SWITCH CLARIFYE MODEM DDC SIDE VIEW (CROSS SECTION) NON DEMISING WALL BEHIND DX. FIELD LOCATE 2 GANG DRYWALL RING IN THIS WALL / / / / / CLARIFYE SWITCH / / CLARIFYE ROUTER I / — / MERAKI MS200 / / MERAKI MX64 MANAGED / / ROUTER SWITCH 1 / / / / ✓ \\\\\\\\\\\\\\4\ DDC TOP SHELF -TOP VIEW NON DEMISING WALL BEHIND DDC.- FIELD LOCATE 2 GANG DRYWALL RING IN THIS WALL / / / -✓ / / / DOCTOR ROUTER DOCTOR SWITCH / / / / LINKSYSI I E2500 / ` DGS1008-G / / ✓ \\\.\\\\\\\\\\Nu\ NON DEMISING WALL BEHIND DDC. FIELD LOCATE 2 GANG DRYWALL RING IN THIS WALL OPTICIAN'S NETWORK DDC MIDDI F SHFI F TOP VIEW CLARIFYE MODEM \ \ \ \ \ \ \ \ \ \ \ \ \ \ DDC BOTTOM Of CABINET -TOP VIEW LABEL CABI E WITHIN 2 INCHES OF TERMINAL ION. 24-PORT CAT6 PATCH PANEL 'PPA' 24-PORT CAT6 PATCH PANEL'PPB' I� I uuul 24-PORT CATS PATCH PANEL WC---1..„„ 8a 7 32-PORT CAT6 PATCH PANEL 'PPppprr�-----���I c HORIZONTAL CABLE ' �I ®I��Cfft� MANAGEMENT (HCM-2D) NI L-- SSS i SPACE FOR OWNER ELECTRONICS RACKSHELF (1UV) RACKSHELF (1UV) WALL RACK (WM-15-18) (15RU) RACKSHELF (1UV) BOTTOM OF RACK TO BE 6 FT AFF (APPROX. AS FIELD CONDITIONS PERMIT, BUT NO LOWER THAN SET AFF OR WITHOUT GHER HAN B FT AFF WITHOUT NEXTORE PROJECT MANAGER APPROVAL) rir" 1f�sR• �� pi MVO 8 48-PORT CAT6 PATCH PANEL 'DDC' ' (2) CAT6 TERMINATE TO DDC 48 PORT PATCH PANEL a 1 CAT6 (QUANTITY AS NEEDED), PLENUM RATED CABLE. L 4X4 BOX IN WALL WITH SINGLE GANG ACTIVATION FOR DATA OUTLET. TERMINATE REQUIRED NUMBER OF JACKS AND TEST. WHERE FREE AIR WIRING IS PERMITTED BY THE LANDLORD AND LOCAL JURISDCEION, UTILIZE 1-HOOKS SPACED PER TIA/EIA STANDARDS. WHERE CONDUIT IS REQUIRED, SIZE PER FILL CHART. ROUTE CONDUIT 6" ABOVE WALL AND BUSH END. SIZE CONDUIT PER FILL CHART. LABEL CABLE WITHIN 2 INCHES OF f TERMINATION. PLATE FINISH TO MATCH ADJACENT RECEPTACLE FINISH. EXISTING PHONE BOARD LABEL EACH OUTLET Wo 6 7 MAXIMUM ALLOWABLE CONDUIT FILL (AUGMENTED CAT6) 3/4" C INC 1 1/4"C 1 1/2"C 2"C 2 DATA CABLES 4 DATA CABLES 7 DATA CABLES 10 DATA CABLES 18 DATA CABLES COMPLIIC�TH 1 NFPA 7700 - EC 2 i 2111 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 052070 PERMIT CENTER LC003 COMMUNICATIONS RISER ELECTRICAL INFORMATION DESIGN ENGINEERING CONSTRUCTION MANAGEMENT: NEXTORE • 4a20 lU6m[imwon 001450+0 • i Cranny ear. nil Caw.. MOW ILO r51%%5-6CO3 ••loan 4314100 STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Construction for: Y I 0 0 C 0 CO 4) V 1T) CL Revisions: Mark Date Al2-m.1F LAND M COMMENTS By A2.ffia) BUILDING DEPARTMENT COMMENTS A A A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 EXPRES 1 21 Architect / Engineer lob No.: 029 Nexto a Stole Design Revision No.: 05 Number t 79779 Brand Design Type: LC.05 ISSUED FOR: El Construction Title ELECTRICAL DETAILS Date 12-9-19 Drawn By STAFF Checked By MPR Slice! E004 LC-05432-00 WALL UNIT 24 LAC jLC-05401-00 WALL UNIT 48 WITH MIRROR ELECTRIC ONE LINE DIAGRAM FIELD VERIFY ALL CONDITIONS DESIGN ENGINEERING CONSTRIKIION MANAGEMENT Ll u • Electrical Requirements Driver *1 (wattage): 90 W Driver #2 (wattage): 90 W Driver #3 (wattage): 90 W Driver #4 (wattage): Total LED Lighting Watts 238 W 3, =as----� 5' 5" 0 05432-00 f==== =1' i====+==== 1 I 05401-00 finished floor LC-05432-00 WALL UNIT 24 LAC LC-05401-00 WALL UNIT 48 WITH MIRROR GEN-DIGM01-00 MIRROR SMART SHOPPER w/MONITOR 46' TOUCH el- 1' 10"-/ 1. ®2 GEN DIGMO1-00-LOC8 GEN-DIGM01-00 MIRROR SMART SHOPPER w/MONITOR 46" TOUCH LC-05431-00 WALL UNIT 24 WITH MIRROR r finished floor 05431-00 Electrical Requirement Driver #1 (wattage): 90 W Driver #2 {wattage): 90 W Total LED Lighting Watts 119W EX (4) # 600 MCM & (1) #3 GRD IN EXISTING METER & 400 AMP FUSED DISCONNECT. VERIFY CONDITION. EXISTING LANDLORD ELECTRICAL SERVICE EXISTING ELECTRICAL SERVICE 120/208V, 3PH, 4W LANDLORD (4) # 600 MCM & (1) #3 GRD IN 3-12" C TENANT NEW SOA/NF/WP/3P NEW RTU-1 NEW 35A/NF/WP/3P NEW HP-1 (OUTDOOR) NOTE: VERIFY THAT THERE ARE WP/GFI RECEPTACLES NEAR NEW RTU AND NEW HEAT PUMP. IF NOT, PROVIDE NEW WP/GFI RECEPTACLES, CIRCUIT TO A-6. TENANT #F696 NEW (3) #8 (1) #10 GRD IN 3/4- C NEW (3) •8 & (1) #10 GRD IN 3/4 C NEW 20A/NF/WP/1P WITH 15A FUSEgi NEW FC-1 (INDOOR) ROOF PROVIDE SPLICE BOX TO EXTEND CONDUIT AND CONDUCTORS TO RELOCATED PANELS. RELOC. PANEL 'A' 120208V, 3 PHASE, 4W 400A MCB RELOCATED TIME CLOCK NEW PANEL 'BP 120/208V, 3 PHASE, 4W 400AMP MLO NEW (3) #12 GRD IN /Y C 4) 4600 MCM & (1) 93J GRD & (1).3 ISOLATED GROUND IN 3-1/2" C. RELOC. FACP CLILIIJG FIRST FLOOR NOTES: 1. ALL EQUIPMENT SHALL BE SERIES RATED. 2. IF THERE ARE ANY DISCREPANCIES WITH THESE PLANS, PLEASE CONTACT THE ENGINEER 3. PANELBOARDS, METER SOCKET ENCLOSURES. ETC.. THAT ARE LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING. OR MAINTENANCE WHILE ENERGIZED SHALL BE HELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS PER NEC 110.16. (1) #1/0 GRD IN 1" C TO BUILDING STEEL PER N.E.C. COMMISSIONING NOTE: SET TIMECLOCKS TO CONTROL DISPLAY WINDOW CIRCUITS AND SIGNS PER MALL OPERATION HOURS. LC-05431-00 WALL UNIT 24 WITH MIRROR • 00300-00 00300 00 RB-02704-00_ SMART SHOPPER FOR SHOP IN SHOP 21.01„ It 2 i-1' 112 --sr-r II1PL 02704-00 LC-05305-00 SELECT TABLE SINGLE 05305-00 RB-02704-00 SMART SHOPPER FOR SHOP IN SHOP LC-05305-00 SELECT TABLE SINGLE 00300-00 ELECTRICAL LOAD SUMMARY PANELS "A" & "B" LOAD DESCRIPTION CONNECTED LOAD (KW) DEMAND FACTOR DEMAND FACTOR (KW) LIGHTING 2.08 1.25 2.61 TRACK LIGHTING 1.87 CURRENT LIMITED 1.87 SHOW WINDOW RECEPTACLES 0.72 1 0.72 SIGN 1.20 1.25 1.50 RECEPTACLES 41.80 <10K=100%; >10k=10k+50%>10k 25.90 EQUIPMENT 1.50 1 1.50 WATER HEATING 6.00 1.25 7.50 HVAC 30.05 1.25 OF LARGEST MOTOR 33.83 TOTALS: 85.22 TOTALS: 75.42 AMPS (208V) 236.83 AMPS (208V) 209.60 IOKC-00361-00_OAKLEY PRESCRIPTION TABL ILC-05450-00 MIRROR 24 E t 9 00361-00 05450-00 OKC-00361-00_OAKLEY PRESCRIPTION TABLE LC-05450-00 MIRROR 24 DESIGN DRAWINGS ARE SCHEMATIC. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GENERAL CONTRACTORS COST. BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT GENERAL CONTRACTORS COST. BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. NOTE PROVIDE FIRE STOPPING FOR ALL PENETRATIONS OF FIRE WALLS. PROVIDE THROUGH WALL FIRE STOPPING FOR ALL LOCATIONS WHERE JUNCTION BOXES ARE LOCATED IN A DEMISING WALL, OR OTHER FIRE WALL Panel Name: Voltage: Amps: MAIN: RELOCATED PANEL A 12D/m8 400 MCB MAIN CIRCUIT BREAKER Panel Type: PANELBOARD AIC Rating: 10K NOTE: ALL BREAKERSSHOWN BOLD TO BE NEW WATTS PER PHASE A B 12 474 Load Characteristics: Total Load, Phase A: Total Load, Phase B: Total Load, Phase C: Total Panel Load: C 472 720 1260 1260 1 DESCRIPTION OF LOAD IGHTNG - SALES TRACK IGHTING • SALES TRACK LIGHTING - SALES TRACK LIGHTING - SALES TRACK LIGHTING • SALES AMBIENT LIGHTING-00 LIGHTING - OD LIGHnN6 - SHOW WINDOW RECEPTACLES - SHOW WINDOW LIGHTING- FRONT FLOODS RECEPTACLES - EXAM RECEPTACLES - EXAM RECEPTACLES -PRETEST RECEPTACLES -PRETEST RECEPTACLES -PRETEST RECEPTACLES -PRETEST RECEPTACLES -DOCTORS CABINET RECEPTACLES- DOCTORS CABINET RECEPTACLES • MANAGERS DESK RECEPTACLES • MANAGERS DESK RECEPTACLES -GENERAL 6019 Totals OCPD CKT# CKT# OCPD DESCRIPTION OF LOAD 20/1 1 2 15/2 20/1 3 4 20/1 20/1 20/1 2oJ1- 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 Voltage (360 for 120(208) 360 27781 Amps per Phase A: 31742 Amps per Phase B: 25699 Amps per Phase C: 85222 Total Amps (assumes balanced): 77 88 71 237 5 7 9 11 13 15 17 19 21 23 25 27 29 31 35 37 39 41 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 At/1 30/3 5D/3 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 NEW PC-1 (INDOOR) RECEPTACLES - ROOF TOP NEW HP•1 (OUTDOOR) NEW RTU-1 RECEPTACLES - REFRIGERATOR RECEPTACLES - MICROWAVE RECEPTACLES -FRAME WARMER RECEPTACLES - LAB RECEPTACLES RECEPTACLES - LAB - LAB RECEPTACLES - LAB RECEPTACLES -CONTACTS RECEPTACLES • CONTACTS EWC RECEPTACLES- LIGHTBO% RECEPTACLES • LIGHTBOX Totals £UQ /O 7 WATTS PER PHASE Panel Name: NEW PANEL B Voltage: 120/208 Panel Type: PANELBOARD Amps: 400A AIC Rating: 10K Main: MLO MAIN LUG ONLY WATTS PER PHASE WATTS PER PHASE A B C DESCRIPTION OF LOAD OCPD CKT# CKT# OCPD DESCRIPTION OF LOAD A B C 501 120D RELOCATED FACP 20/1 1 2 20/1 RECEPTACLES- FLOOR DISPLAY 1080 r:r 1080 EXTERIOR STORE FRONTSIGN 20/1, 3 4 20/1 RECEPTACLES - FLOOR DISPLAY 20/1 5 6 20/1 RECEPTACLES- FLOOR DISPLAY 3000 3000 1200 WATER HEATER 40/2 7 8 20/1 RECEPTACLES- RECEPTION BACKWRAP 360 36D 180 9 10 20/1 RECEPTACLES- RECEPTION DESK RECEPTACLES - LED WALL 20/1 11 12 20/1 RECEPTACLES- RECEPTION DESK 12CC RECEPTACLES- LED WALL 20/1 13 14 20/1 RECEPTACLES- CASHWRAP BACKWRAP 360 540 360 ' ""+ ' •- 20/1 15 16 20/1 RECEPTACLES- CASHWRAP SPARE r 17 , 18 20/1 RECEPTACLES - CASHWRAP SPARE g 1 19 20 20/1-SPARE 1778 1260 SPARE 0/1 21 22 20/1 RECEPTACLES- UGHTBOX SPARE ,0/1 23 24 20/1 RECEPTACLES- FLOOR DISPLAY CASE 920 1527 RECEPTACLES - LIGHT BOX r 1 25 26 20/1 RECEPTACLES- FLOOR DISPLAYCASE 1440 1800 1800 RECEPTACLES- LIGHT BOX 1 27 28 20/1,RECEPTACLES- FLOOR DISPLAY CASE SPARE .r 1 29 30 20/1 RECEPTACLES- FLOOR DISPLAY CASE 601 601 '' 360 as 1500 1500 1503 SPARE :r/1 31 32 20/1 RECEPTACLES- FLOOR DISPLAY CASE 1620 1080 720 PAaE .. w es A d , 20/1 33 34 20/1 RECEPTACLES- FLOOR DISPLAY CASE SPARE 20/1 35 36 20/1 RECEPTACLES- FLOOR DISPLAY CASE ' - 38 20/1 RECEPTACLES -FLOOR TABLE 360 360 36F ERV-1 2012 41 40 42 r, 1 20/1 RECEPTACLES• FLOOR TABLE RECEPTACLES- FLOOR TABLE > - " • : • '' 'n .c 44 20/1 RECEPTACLES- FLOOR DISPLAYCASE 720 RECEPTACLES-PHONEBOARD 20/1 45 46 20/1 SPARE -- .. . 48 20J1 SPARE ERV HEATER 20/3 SO 20/1 SPARE 53 52 54 21 1 SPARE 2Q11 SPARE ! .- err:. Voltage (360 for 120/208) 360 Amps per Phase A: 37 Am s p per Phase B: 46 Amps per Phase C: 25 Total Amps Iassumes balanced): JCS 1 nEvtavvec PoW I `{oF ; :, n 6998 5760 Load Characteristics: Total Load, Phase A: 13421 Total Load, Phase B: 16386 Total Load, Phase C: 9061 Total Panel Load: 36868 COMPLIANCE OATH NFPA 7D-NEC tl� CITY CiF 'i ut���iELA , 2 " " a 1oG' MAR 0 5 2020 n 1 City of Tukwila , -pg i NEXTORE • AM I.MU Ncc macs. Or +SW • • 1 G,]. ASH6 •a truing, fi a*. Eat Cr.N* :l]HYE •.1(iPats197D3 STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Construction for: Revisions: Mark Date A 12-18.14 By LANOWRD COMMENTS A Z-28-20 BUKOMG NPARTA/ENT COMMENTS A A A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 EXPIRES it-OUI Architect / Engineer Job No.: 029 Nextore Store Design Revision No.: 05 Nextore project Number 79779 Brand Design Type. LC.05 ISSUED FOR: 53 Construction Title ELECTRICAL GENERAL NOTES & DETAILS Date 12-9-19 Draem Sy STAFF Checked By MPR Sheet E005 GENERAL DEMOLITION NOTES ® KEY NOTES - ELECTRICAL DEMOLITION DESIGN ENGINEERING CONSTRUCTION MANAGEMENT. A. B. C. D. E F. G. H. IN EVERY INSTANCE OF DEMOLITION AND/OR REMODELING, THE E.C. SHALL FIGURE A COMPLETE JOB AS NONE OTHER SHALL BE ACCEPTED. THE DRAWINGS ARE TO BE USED ONLY AS A GUIDELINE FOR DEMOLITION. THE EC. MUST VISIT THE SITE PRIOR TO BIDDING TO VERIFY ALL WORK REQUIRED FOR A COMPLETE JOB & INCLUDE THE COST OF SUCH WORK IN HIS BID. THE EC. SHALL MAINTAIN EXISTING SERVICES TO & IN THE EXISTING AREA AS REQUIRED. IF NECESSARY, THE E.C. SHALL PROVIDE TEMPORARY SERVICES IN THE EXISTING AREAS. THE E.C. SHALL DISCONNECT & REMOVE ELECTRIC SERVICE TO ALI. MECHANICAL EQUIPMENT BEING REMOVED AS A RESULT OF THE REMODELING. ELECTRICAL EQUIPMENT & DEVICES SHALL BE REMOVED COMPLETE INCLUDING CONDUIT & WIRE FLUSH MOUNTED WALL OUTLETS SHALL BE REMOVED AND THE WALL PATCHED AND FINISHED TO MATCH THE ADJACENT WALL FINISHES. ANY EXISTING CONDUIT, WIRING AND/OR ELECTRICAL & MECHANICAL DEVICES BEING DISTURBED BY THE WORK SHALL BE REWORKED BY THIS CONTRACTOR AS REQUIRED TO RETURN TO ITS FORMER EXISTING OPERATING CONDITION. I. ANY CIRCUITS FEEDING THROUGH DEVICES OR EQUIPMENT BEING RELOCATED, REWORKED, OR ABANDONED & SERVING OTHER ELECTRICAL DEVICES, AND/OR EQUIPMENT SHALL BE MAINTAINED BY PROVIDING J-BOXES OR OTHER ACCEPTABLE METHOD AS REQUIRED. J. ALL WALLS, CEILINGS, FLOORS, ETC., BEING DISTURBED BY THE WORK SHALL BE RETURNED TO FINISHED CONDITIONS TO MATCH EXISTING BY THE E.C. & HE SHALL DO HIS OWN CUTTING & PATCHING AS NECESSARY UNDER HIS CONTRACT. K. L EXISTING MATERIALS SHALL BE TURNED OVER TO THE OWNER. IF NOT REQUIRED BY OWNER, THE E.C. SHALL REMOVE THESE MATERIALS FROM THE PREMISES. NO CONDUIT, BOXES, WIRING, OR CABLES SHALL BE INSTALLED WITHIN 1 12- OF THE LOWEST POINT OF THE UNDERSIDE OF THE ROOF DECKING, NOR SHALL THEY BE INSTALLED CONCEALED WITHIN METAL -CORRUGATED ROOF DECKING. THE E.C. SHALL BE RESPONSIBLE TO REPLACE AND/OR REWORK EXISTING CONDUIT, BOXES, WIRING, AND CABLING THAT IS NOT IN COMPLIANCE WITH THIS REQUIREMENT- M. ALL CONDUIT AND CABLING SHALL BE PROPERLY SUPPORTED AS REQUIRED BY THE NATIONAL ELECTRICAL CODE THE EC. SHALL BE RESPONSIBLE TO REPLACE AND/OR REWORK EXISTING CONDUIT AND/OR CABLING THAT IS NOT IN COMPLIANCE WITH THIS REQUIREMENT. N. E.C. SHALL FIELD VERIFY SLAB ON GRADE FLOOR CONSTRUCTION TYPE PRIOR TO CURING. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR CUT A STRUCTURAL FLOOR SLAB THICKER THAN FOUR (4") INCHES WITHOUT PRIOR WRITTEN APPROVAL FROM ENGINEER OF RECORD. NOTIFY ENGINEER OF RECORD OF ANY SLAB THICKNESS GREATER THAN FOUR (4") INCHES PRIOR TO PROCEEDING WITH ANY SAW CUTTING. II m'P->F_J L. r_, 1 1 L_J T I 41 11111 ki I I N II I II I I I I 1 *0 I I �I L_J II L__J I r ©©00 MT.) // \\ / 1 0\ %, I L_J r-1 r-1 I 1 1 1 L__J L_J R` � F— — (TYP., 0 C` E IZI C 1. DISCONNECT AND SALVAGE EXISTING PANELBOARDS AND TIMECLOCKS, 2. DISCONNECT AND REMOVE ALL EXISTING LIGHT FIXTURES. 3. REMOVE DEVICES ON WALLS TO BE DEMOLISHED. VERIFY EXACT QUANTITY ON SITE. 4. DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES, SWITCHES ETC AS REQUIRED TO PROVIDE THE ELECTRICAL AS SHOWN ELSEWHERE ON THESE PLANS. 5. DISCONNECT AND REMOVE EXISTING SHOW WINDOW RECEPTACLES. G DISCONNECT AND REMOVE EXISTING CEILING FAN. SALVAGE CIRCUITS FOR REUSE 7. DISCONNECT AND REMOVE EXISTING PHONE BOARD. ALL EQUIPMENT ON PHONE BOARD TO BE SALVAGED AND RELOCATED TO NEW PHONE BOARD LOCATION. SEE SHEET E201 FOR NEW LOCATION. a EXISTING DEVICE TO REMAIN. MOVE DEVICE IF THE DEVICE INTERFERES WITH NEW STORE FRONT. VERIFY IF THE DEVICE IS A LL DEVICE AND IF SO CONTACT LL BEFORE MOVING. 9. DISCONNECT AND SALVAGE EXISTING FIRE ALARM DEVICES FOR RELOCATION. SEE SHEET E201 FOR NEW LOCATION. 10. DISCONNECT AND REMOVE EXISTING SECURITY DEVICE 11. DISCONNECT AND REMOVE POWER TO EXISTING WATER HEATER 12. EXISTING DOOR BELL PUSH BUTTON TO REMAIN. 13. DISCONNECT AND REMOVE EXISTING SPEAKERS. 14. DISCONNECT AND SALVAGE EXISTING DOOR BELL SYSTEM FOR RELOCATION. SEE SHEET E201 FOR NEW LOCATION. 15. EXISTING FIRE ALARM DEVICES TO REMAIN. 16. EXISTING TRAFFIC COUNTER TO REMAIN. 17. DISCONNECT AND REMOVED POWER TO EXISTING MECHANICAL UNITS. SALVAGE EXISTING CONDUIT AND CONDUCTORS IF POSSIBLE WITH NEW MECHANICAL UNITS. 18. EXISTING MALL LIGHTING TO REMAIN. MOVE LIGHTING IF THE LIGHT INTERFERES WITH NEW STORE FRONT. CONTACT LL BEFORE MOVING. 19. DISCONNECT AND REMOVE EXISTING LAB EQUIPMENT. I y ir I 0 ul r-1 I I L_J Oe 1,1 (s' GE19 r-1 (S. r-1 I rt1 I JI —Itj I sit r--I I L_J to L_J r,- 4' Lr i I LI l / IJ // /Ji I \ / / / �19 a DIET r—i r I I _J__11 _ 3 _0_ >Z _ I I L_J MOTION kETECTOR I r L I 0 1--1 ® II �, \\ \\\\ \�_L_J • • / i// Oy L_—I ©©oo // ` \ // ` \ // `\\ // < ,\" < r I I L_J 0FA STROBE r L_J WIFI �W / r Cy `' \• \ 1 kl `�\� L_J `/ L_J P%% Ir 0 ray 0 r-1 I I L_J ELECTRICAL - DEMOLITION SLUE: Vs • T-0` r-1 I 1 L_J r-1 /i' I I [f L_J C (TYP) a I SI 0 r-1 I I L_J ran I 1 L_J r I I L_J /n\ i/ �\ / \ / \\ \ /' r-1 \\ \ 'C I I \ \ \\ L_J \•• \ ` \\• \ \ (te) • r L_J r--I 1-_I— L_J (s, r-1 I I L_J r-1 I I J L_J ey El 0 C' C' EXISTING TO REMAIN r-1 `1 L__r `\ / I I \\/ L J r-1 I 1 L_J r-I (TYP.) 0 r-1 I I L_J 71 (TVP.) ■ 1 BORE • OLC LoiMr Net Mao- D, LSAU •6C ®¢l Erl to y. C 002E •.I ou n, eax •-1:86i:5tAW STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Construction for: Revisions: Mark Date A 12-18-19 BY LANDLORD COMMENTS / \ 248-20 WILDING DEPARTMENT COMMENTS A A A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 EC l 9-/067 (16 ThgVIEWED FOfi 1 COMPLIANCE 1NITH' NFPA 70 - NEC :,'A 2 aUil City of Tukwila 4 BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 0 57070 PERMIT CENTER EXPIRES 2041 Architect / Engineer lob No.: 029 Nextore Store Design Revision No.: 05 Nextore project Number 79779 Brand Design Type: LC.05 ISSUED FOR: ® Construction Title ELECTRICAL DEMOLITION PLAN Date 12-9-19 Drawn By STAFF checked By MPR Sheet E100 GENERAL NOTES LANDLORD NOTES LANDLORD REVIEW COMMENTS 1125I19 NOTE @ KEY NOTES - LIGHTING PLAN DESIGN ENGINEERING CONSTRUCTION MANAGEMENT. A. EMERGENCY (EM) LUMINAIRES THAT ARE NOT WIRED TO A CENTRAL INVERTER SYSTEM NOR SHOWN WITH "NU SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT' TO PROVIDE CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. B. ALL NIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING C. IT SHALL BE THE E.C: S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. D. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON -SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. E. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION. F. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. G. LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO 1S0'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. H. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE THRU-WIRING WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. I. E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY NEXTORE E.C. IS RESPONSIBLE TO ENSURE THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. J. EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. K. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. L EC. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF AU. EQUIPMENT, FIXTURES AND MILLWORK PRIOR TO CONNECTION. 1.11114MMUGHTS POWs Ptrt MN Mr i wry• '�' NN St -fret.. haw Crocco i 62400 Panel PAS Sad 6., swam WATTSTOPPER MODEL W2000A WATTSTOPPER MODEL W2000A LIGHTS MULTIPLE SENSOR, MULTIPLE POWER PACK (CONFIRM WITH CURRENT MANUFACTURER LITERATURE) OS OS: OCCUPANT SENSOR, WALL MOUNTED, WHITE (- - UNSWITCHED CIRCUIT WALL SENSOR/DIMMER COMBINATION NOTE ALL WIRING BY THE ELECTRICAL CONTRACTOR. E002 OCCUPANCY SENSOR SCHEMATICS E002 p ENERGY CODE - COMMISSIONING 1. 2. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE OFFICE AREA 1.1. OCCUPANCY SENSORS DETECT MOTION AND ENERGIZE THE LOCAL SWITCHING. 1.2. OCCUPANCY SENSORS DE -ENERGIZE AFTER NO MOTION IS DETECTED AFTER A 30 MINUTE DELAY. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE SALES AREA: 2.1. SIGNS, PERIMETER SHELVING AND SALES FLOOR DISPLAY CABINETS ARE ENERGIZED AND DE -ENERGIZED WITH THE TIMER SWITCH OR CONTACTOR CONTROLLED BY TIMECLOCK. E012 ENERGYCODE - COMMISSIONING SMALL • IF USED - SPEAKERS SHOULD BE RECESSED - NOT SURFACE MOUNTED. • IF USED ANY PEOPLE COUNTER SYSTEMS MUST BE CONCEALED FROM VIEW AT STOREFRONT. • ALL EMERGENCY AND EXIT UGHTING IN FRONT OF HOUSE MUST BE EDGE LIT AND HAVE RECESSED BASE - NO SURFACE MOUNTED. • CUT SHEETS OF ALL IJGHTNG FIXTURES IN FRONT OF HOUSE MUST BE SUBMITTED TO LANDLORD FOR APPROVAL CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR SHALL REVISE CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA AS WELL. AS CIRCUITS THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT. RECESSED LIGHT FIXTURES INSTALLED IN A PLENUM SPACE SHALL BE PLENUM RATED. LIGHTING AND EMERGENCY LIGHTING POWER DENSITY LOCATION SALES AREA 24485Q. FL EMERGENCY FIXTURE DESCRIPTION 2-LAMP LED ADJUSTABLE DOWNUGHT WATTS 40 QUANTITY 22 CONTROLS TIMECLOCK EMERGENCY LIGHTING TOTAL WATTS 840 EMERGENCY LIGHTING POWER DENSITY (W/SF. FT.) 0.34 SPACE TOTAL WATTS 2337 LIGHTING POWER DENSITY (W/SF. FT.) 0.95 BACK OF HOUSE 1457SQ. FT. LED 2X2 16 7 OCCUPANCY SENSOR 112 BACK OF HOUSE BACK OF HOUSE CLG. HT.=8'-0' JETER STORAGE 116 CLG. HT.= 9'-0" CONTACT LENS ROOM 104 1 CLG. HT=8'-0" OD RECEPTION/ WAITING AREA 103 CLG. HT.=10'-0" MALE RESTROOM CLG. HT.=8'-0' ALCOVE CLG. HT. 8'-0" FEMALE RESTROOM CLG. HT.= 8'-0" HALLWAY #2 CLG. HT.= 9'-0' HALLWAY #1 CLG. HT.= 9'-0' FUTURE PRE -TEST I115I CLG. HT = 8'-0" 1-IAMP LED DOWNUGHT 17 EXAM 105 CLG. HT = 6-0" RELOCATED TIMECLOCK FUTURE PRE -TEST 114 CLG. HT.=8'-0" 12 OCCUPANCY SENSOR TOTAL BON O(TYP) OS EXAM 113 CLG. HT.=8'-0" 204 316 O(TYP) 0.21 URGENT CARE LAB 102 CLG. HT=9'-0" PRE -TEST H 1® CLG. HT.=B'-IT 1057 ROUTE TO SWITCH^"SW8" L►El A-9 ROUTE TO SWITCH "SW5' ROUTE TO SWITCH »SW& 0.72 ELECTRICAL - LIGHTING SCREE I/6•. Y4 RETAIL SALES AREA 101 CLG. HT.= 10'-6" 1. CIRCUIT VIA MASTER LIGHTING SWITCH BANK. SEE DETAIL E001. 2. NEW LIGHTING SWITCH BANK. SEE DETAIL E001. IF LOCATION IS UNDESIRABLE, FIELD VERIFY EXACT LOCATION WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH -IN. 3. ROUTE UNSWITCHED CONNECTION TO EXIT SIGNS AND EMERGENCY DOWNLIGHTS. WHERE FIXTURES ARE SWITCHED, ROUTE ADDITIONAL POWER FROM THE SAME CIRCUIT AHEAD OF ALL SWITCHING FOR POWER LOSS SENSING. 4. PROVIDE OCCUPANCY SENSOR FOR AUTOMATIC SHUT OFF OF ROOM LIGHTING. SEE DETAIL E002. S. CIRCUIT ROUTED THRCRIG : • I URRENT LIMITING SUBPANEL). 6. THE REMAINING FIXTURES ON THIS RUN ARE BAC © P BY AN INVERTER (FIXTURE RP2). CONNECT FIXTURES AS SHOWN IN DETAIL SUCH THAT THE SWITCH IS OVER -RIDDEN DURING A POWER FAILURE, AND EMERGENCY FIXTURES ARE SWITCHED WITH THE SALES FLOOR LIGHTS. SEE DETAIL E004. 7. NEW EMERGENCY BATTERY UNIT RP2. WIRE TO CIRCUIT SHOWN. COORDINATE INSTALLATION LOCATION WITH NEXTORE PROJECT MANAGER. MOUNT BELOW CURRENT LIMITING PANEL SEE E004. RAY -BAN AREA 101E CLG. HT.=10-6' OAKLEY AREA 1O1C CLG. HT=10'-6" aowno . SWITCH "SW4- ROUTE TO SWITCH "SW" 61.)9%/40‘ 7 INTERIOR STOREFRONT 101A CLG. HT =12'-7" ROUTE TO SWITCH "SW1" A-15 0 S %6) REVIEWED EON - COMPLIANCE WITE H NFPA TO - NEC .. : 2 nit, CIty of Tukwila BUILDING DIVISION nECRIVE?. CITY OF -I a 6:S11 tL.A MAR 0 5 MA PERMIT CENTER NEXTORE •coz U.*C° awe MST 014500 •6Cx«n' *a Est Getty CTasn • .13t3, mows • .1$66;43l-9w1 STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Constructionn for: v LU U- C U tin Z Revisions: Mark Date By Ql 122-10-1ST LANDLORD COMMENTS p2.2a.3) BUILDING DE PARTME NT COMMENTS A A A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920)445-5007 EXPIRES 121421 Architect / Engineer lob No.: 029 Nextore Store Design Revision No.: 05 Nextore project Number 79779 Brand Design Type: LC.05 ISSUED FOR: IN Construction Tide ELECTRICAL LIGHTING PLAN Dale 12-9-19 Drawn By STAFF Checked By MPR Sheet E200 ® KEY NOTES - ELECTRICAL PLAN 1. NEW WATER HEATER LOCATION. 2. INSTALL OWNER FURNISHED AUDIO SYSTEM INCLUDING CABLE, BACK BOXES, SPEAKERS AND VOLUME CONTROL. PROVIDE 3/4' CONDUITS FOR ALL WIRING IF REQUIRED FOR ACCESSIBILITY, LOCAL CODE OR LANDLORD REQUIREMENTS. INCLUDE ALL WORK REQUIRED FOR A COMPLETE SYSTEM IN BID. WHERE A ARE ALARM SYSTEM IS PRESENT. PROVIDE RELAY TO DISCONNECT POWER TO MUSIC SYSTEM WHEN FIRE ALARM SYSTEM IS IN ALARM. 3. LOCATION OF THE DOCTORS DATA CABINET (DDC. SEE DETAIL LC002 FOR DEVICE INSTALLATION. 4. TELEPHONE TERMINAL BOARD::4'x8'x3/4" FIRE RATED PLYWOOD, MOUNT TIGHT TO THE CEILING. PROVIDE PHONE BOARD FOR RETAIL SALES SIDE OF SPACE AND DOCTORS/REFRACTION SIDE OF SPACE. SEE DETAIL LC003. 5. PROVIDE POWER AND TELE/DATA FOR FLOOR FURNITURE FEEDS. PROVIDE DEVICES AND DEVICE QUANTITIES AS SPECIFIED IN FIXTURE CUT SHEETS PROVIDED BY FURNITURE MANUFACTURER. EC SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS WITH FURNITURE MANUFACTURER REPRESENTATIVE. 6. EC SHALL PROVIDE DATA CABLE FROM TELEPHONE BOARD TO 24' ABOVE CEILING FOR CONNECTION TO SHOPPERTRAK SYSTEM(BY OTHERS). PROVIDE MINIMUM 6 FT COILED CABLE AT BOTH ENDS. SHOPPERTRAKER MUST BE RECESSED STYLE. 7. LOCATION OF DDC (24-PORT CAT 6 PATCH PANEL CLARIFYE 8-PORT MANAGED ETHERNET SWITCH, DOCTOR SWITCH DOCTOR ROUTER, CLARIFYE MODEM & CLARIFYE ROUTER). GC SHALL INSTALL A DRYWALL RING BEHIND DDC. All DATA UNES RUNNING TO AND FROM DDC SHALL RUN THROUGH DRYWALL RING. OUTLETS IN WALL NEED TO BE LOCATED AT 18" AF.F. BEHIND THE DDC. ALL CABLE SHALL BE LEFT HANGING LOOSE FOR LUXOTTICA LT. TO MAKE FINAL CONNECTIONS. ALL CABLES SHALL BE LABELED PER PLAN. SEE DETAIL LC002. 8. K SHALL PROVIDE A-CAT6 DATA CABLE FROM TELEPHONE BOARD TO 24" ABOVE CEILING FOR CONNECTION TO WIRELESS ACCESS POINT. COORDINATE EXACT LOCATION WITH PROJECT MANAGER PRIOR INSTALLATION. 9. FAN TO BE CONTROLLED WITH LIGHT SWITCH FROM ROOM. 10. PROVIDE A RECESSED CLOCK STYLE OUTLET BOX FOR THE RECEPTACLE AND DATA OUTLET AT THE LED WALL. VERIFY EXACT MOUNTING LOCATION WITH NEXTORE PROJECT MANAGER PRIOR TO INSTALLATION. 11. PROVIDE JUNCTION BOX AND DISCONNECT SWITCH FOR 20A SIGNAGE CIRCUIT. SWITCH SHALL SHUT-OFF SIGNAGE CIRCUIT. LABEL SWITCH FOR WHAT IT SERVES. DISCONNECT SWITCHES SHALL BE LOCATED ABOVE CEILING IN AN ACCESSIBLE AREA IN THE BACK OF THE STORE OR AT AN ACCESS PANEL LOCATION AND GROUPED TOGETHER 12 PROVIDE CORE DRILLING OR TRENCHING (AS APPLICABLE) FOR POWER AND TELE/DATA. EC. SHALL VERIFY ALL CORE DRIWNG REQUIREMENTS WITH THE LANDLORD PRIOR TO THE START OF WORK. PROVIDE DEVICES AND DEVICE QUANTITIES AS SPECIFIED ON PLANS. EC SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS WITH FURNITURE MANUFACTURER REPRESENTATIVE. 13. FINISH OF FLOOR BOXES SHALL BE BRUSHED ALUMINUM. COORDINATE WITH THE G.C. PRIOR TO PURCHASING. 14. CONTROL CIRCUIT THROUGH LIGHTING SWITCH BANK. SEE DETAIL E001. 15. INSTALL LEVITON LOW PROFILE RECESSED ENTERTAINMENT BOX AT LOCATION INDICATED ON ARCHITECTURAL ELEVATION FOR SUPPLY TO DIGITAL EYE CHART. EXACT DIMENSION IS CRITICAL PROVIDE THE DEVICES INDICATED . PROVIDE ALSO A 1 1/2" CONDUIT FROM BOX TO JUNCTION BOX UNDER THE EXAM DESK. SEE DETAIL LC001. 16. DOOR STROBE/BELL SYSTEM IS COMPRISED OF (3) COMPONENTS. (1) SERVICE DOOR PUSH-BUTTON (1) STROBE/BELL LOCATED ABOVE GENERAL MANAGER'S (GM) DESK AT AN ELEVATION OF 8'-0', AND (1) TRANSFORMER LOCATED NEXT TO STROBE/BELL SEE DETAIL E006. 17. PROVIDE NEC 517 REDUNDANT GROUNDING FOR RECEPTACLES AND SWITCHES/DIMMERS IN THIS ROOM. PROVIDE BONDING TO ALL METAL PARTS OF THE RACEWAY SYSTEM TO ENSURE THAT THE RACEWAY SYSTEM ACTS AS A GROUNDING PATH, AND PROVIDE A SEPARATE GROUNDING CONDUCTOR. BOND THE CONDUCTOR AND THE RACEWAY TO THE RECEPTACLES TO CREATE A REDUNDANT PATH TO GROUND. USE HOSPITAL GRADE MC CABLE WHEN MC CABLE IS THE WIRING METHOD USED. RECEPTACLES SHALL BE HOSPITAL GRADE. 18. PROVIDE 'RECESSED" FLOOR BOX/POKE THRU AT THIS LOCATION - SEE DETAIL E008. 19. INDICATED RECEPTACLE WILL BE SERVED BY TWO CIRCUITS. LABEL EACH DUPLEX OUTLET WITH THE CIRCUIT SERVING IT. 20. SEE ARCHITECTURAL ELEVATIONS FOR EXACT PLACEMENT OF ELECTRICAL DEVICES. 21. SOUND SYSTEM SPEAKER. SPEAKERS. WIRING AND ACCESSORIES ARE SUPPLIED AND INSTALLED BY THE SOUND SYSTEM VENDOR. COORDINATE WORK WITH THE VENDOR PRIOR TO CEILING INSTALLATION. SEE DETAIL E007. 22. PROVIDE FLOOR BOX "RECESSED' PER DETAIL E008. PROVIDE CORE DRILLING OR TRENCHING (AS APPLICABLE) AND ROUTE CONDUITS TO WALL CONNECT TO 24 HOUR CIRCUIT AND ROUTE CAT 6 CABLING TO TECH RACK LOCATION AND LABEL ENDS OF CABLING. 23, G.C. SHALL PAINT SHOW WINDOW RECEPTACLES TO MATCH ADJACENT FINISHES. 24. PROVIDE 120V POWER TO DOOR DETER SYSTEM. 25. PROVIDE COMMUNICATIONS RACK AT TELEPHONE BOARD. SEE DETAIL LC002. 26. PROVIDE WIRING FOR TENANT INSTALLED SURVEILLANCE EQUIPMENT. SEE DETAIL E005. 27. ALL OUTLETS TO MATCH FINISH OF ADJACENT SURFACE. UTILIZE LEVITON RENU SYSTEM. PROVIDE CLEAR LABEL WITH BLACK TEXT, 1/4' HIGH ON ALL SWITCHED OUTLETS. LABEL TO READ 'SWITCHED". 2& NOTED WALL DISPLAY CABINET Will BE SERVED BY TWO CIRCUITS. LABEL EACH DUPLEX OUTLET WITH THE CIRCUIT SERVING IT AND LABEL THE SWITCHED OUTLET 'SWITCHED'. 29. VERIFY DEVICES REQUIRED, LOCATIONS, AND INSTALLATION DETAILS AT NOTED LOCATIONS WITH NEXTORE PROJECT MANAGER PRIOR TO PURCHASE. 30. VERIFY PLACEMENT Of DEVICES FOR OAKLEY WALL DISPLAY CABINETS WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH -IN. 31. PROVIDE POWER TO RAYBAN ILWMINATED SIGN. 32. PROVIDE POWER TO OAKLEY ILLUMINATED SIGN. 33. ALL FIRE ALARM WORK TO BE COMPLETED BY THE LL ARE ALARM CONTRACTOR AT TENANT EXPENSE CONTRACTOR TO PROVIDE ANY REQUIRED SUBMITTALS AND CONNECTIONS/REPROGRAMMING TO THE LANDLORD PANEL AS APPLICABLE. 34. PROVIDE MC CABLE WHIP TO BASE OF LIGHT BOX FROM SWITCH ABOVE CEILING, AND CONNECT TO SWITCH IN THE LIGHT BOX (SUPPLIED BY THE LIGHT BOX MANUFACTURER). WIRE FROM THE INTERNAL SWITCH TO THE DRIVERS IN THE LIGHT BOX FRAME, WHICH IS A LISTED WIRE WAY. DRIVERS AND LEDS ARE SUPPLIED AND INSTALLED BY THE LIGHT BOX MANUFACTURER. ALL 120V CONNECTIONS ARE BY THE ELECTRICAL CONTRACTOR. 35. RELOCATED EXISTING BELL/TRANSFORMER 36. COORDINATE LOCATION AND DEPTH OF J-BOX FOR RECEPTACLES WITH POCKET DOOR. 4FT X 8FT PHONE BOARD INSTALLED AT 18' AFF TO BOTTOM. ©O;15 BACK OF HOUSE I106I CLG. HT = A-8,10,12 208V, 3-PHASE JETER 35/3 BREAKER STORAGE 348,1.10- 3/4"C 1T6 21 MCA HP-1 CLG. HT.=9'-0" CONTACT LENS ROOM CLG. HT.=8'-0' (1) 1' FOR POWER AND (1) 1' FOR DATA OD RECEPTION/ WAITING AREA CLG. HT.= it-0" MALE RESTROOM CLG. HT=IT-0" ALCOVE 108 CLG. HT.=8'-0" FEMALE RESTROOM CLG. HT=8'-0" HALLWAY*2 no I CLG. HT = 9'-0" HALLWAY #1 107 CLG. HT. 91-0" FUTURE PRE -TEST 115 CLG. HT.= 8'-0" to 20 11 E010 A-2 ERV HEATER B-49,51,53 208V, 3-PHASE. 20/3 BREAKER 4#12 - 1/2"C 12.5 MCA ` EXAM 105 CLG. HT.= 8'-0" ERV-1 B-39,41 208V, 1-PHASE, 202 BREAKER. 3#12 - 12"C PPA1, PPA2, PPA3, PPA4;' (TYP.) ElkE1 A-21 BMCA Elm 1> PPAS, PPA6, PPA7, PPAB A-394 ❑Y t w) 1E0061> ©5 0A-21 0 Gil RELOCATED FACP Er 114A 0 Fl A-21 Qw. PPA13 - B-12 R1,R2,R3 V 202A 208V, 1-PHASE 15/2 BREAKER 3•12 - 1/2"C BMCA A 24 :A-26 PPD32 p 42" A-2B A-3D PPD30,3 ALL GENERAL USE RECEPTACLES MOUNTED BELOW 5'-6" A.F.F. SHALL BE TAMPER RESISTANT. ALL OUTLETS TO MATCH FINISH OF ADJACENT SURFACE. UTILIZE LEVITON RENU SYSTEM. PROVIDE CLEAR LABEL WITH BLACK TEXT, 1/4" HIGH, ON ALL SWITCHED OUTLETS. LABEL TO READ "SWITCHED" %Wl 1 •` j URGENT RETAIL CARE LAB SALES AREA 102 CLG. HT = 9'-0' B-28 1O ROUTE TO SWITCH-SW3' .R 208V. 1-PHASE, 40/2 BREAKER. 3.8 1#10 - 3/4"C 6KW FRAME WARMER • 0 (CLG) (TYP.) 33 PP014 A-34 -A-14,16,18 208V, 3-PHASE, 50/3 BREAKER 1348, 1*10- 3/4"C 42 MCA A-40 ROUTE TO SWITCH 'SW3' API B-10 V(CLG) PPA9.10,11 vE135OI A40 ROUTE TO SWITCH "SW3" VJCEF A-11 120V, 1-PHASE 20/1 BREAKER 012 - 12'C 1<'104 WATTS • A-41 'GFIJS GA{--49 FIl10i B-1 DEI(CLG) • Q P3AP38 frA-25 Pica LA-25 C P4AP4B RA-27 gliC A-27 A-25: P3EP3F FUTURE PRE -TEST 114 CLG. HT.= 8'-0' A 36 GFI PPC2' (CLG) !; PPD14 PPB13 :paP1EPIE A-31 0(CLG) 2 C • WJ1. WJ2, 1 WJ3, WJ4. -- W15, WJ6 Pt Pi A-31 `... A-27: P4EP4F EXAM i CLG. HT= 8'-0" P1C,P1D QP2E,P2F A-29 (CLG) PPA15V Wp A-23�J ,a A-23- a,.�i Q2&E2B 6 WIT (CLG) PRE -TEST 109 CLG. HT.= 8'-0' B-26 O ROUTE TO SWITCH 'SW3"R PPC 1 CI G) PPCS (CLG) (1) 1" FOR POWER AND (1) 1" FOR DATA B-28 g ROUTE TO SWITCH "SW3" r/ 42-19 8-30(14 ROUTE TO SWITCH "SW3' PPC 12 (CLG) 14 ROUTE TO SWITCH "SW3' 101 CLG. HT.=10'-6' COORDINATION NOTES C01. DO NOT ROUGH IN ANY RECEPTACLES OR DATA OUTLETS ON THE SALES FLOOR WITHOUT FIRST CONFIRMING EXACT LOCATION WITH NEXTORE PROJECT MANAGER CO2. DO NOT PURCHASE FLOOR BOXES WITHOUT FIRST VERIFYING FINISH (FROM MANUFACTURER'S STANDARD) FOR A PARTICULAR BOX IN A PARTICULAR LOCATION. CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR SHALL REVISE CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA AS WELL AS CIRCUITS THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT. NOTE CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR SHALL REVISE CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA AS WELL AS CIRCUITS THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT. RAY -BAN AREA CLG. HT = -24 14 F OUTE TO SWITCH "SW3"N SEE DETAIL E007 (TYP.) (1) 1" FOR POWER AND (1) I" FOR DATA (1) 1" FOR POWER AND (1) 1' FOR DATA O14 B-39 ROUTE TO SWITCH '5W3' ELECTRICAL - POWER/SYSTEMS SCALE V4'-1,' 8-27 ROUTE TO SWITCH 'SW3' OAKLEY AREA 101C l\.T. C;(-)I //� L- B-4 &YP) 2R i (1) 1" FOR POWER: A-24 ROU 0 SWITCH "SW3' CLG. HT=10'-6" 8-2 1F747 ROUTE TO SWITCH 'SW3" ROUTE TO SWITCH -SW9 B-3 (CLG) wPPCB (ft 6) B-4 t(7' ROUTE T SWITCH FOR POWER (TYP.) 23 ROUTE TO SWITCH "SW3'(1) I" FOR POWER A-42 ROUTE SWITCH"- 3 (1) 1" F o . POWER PPC13 (CLG' ierAB-36 ROUTE TO SWITCH "SW3" B-4 t"v ROUTE a SWITCH 3" IP 04, aliffr i V,v. NN A-41 8-22 ROUTE TO SWITCH "SW3' S 1" FOR POWER B TE TO SWI CH "SW3 eLi 9•/00 INTERIOR STOREFRONT LG. HT =12'-7" ROUTE TO I COMPLIANCE IANCE WTH SWITCH "SW2' NFPA 90-NEC •:- i 2 :J�; •. City of Tukwila BUILDING DIVISION RECEIVE) CITY OF -ti ii I 1I-A MAR 0521120 PERMIT CENTER DESIGN ENGINEERING CONSTRUCTION MANAGEMENT NEXTORE •.1(Sit iss-eac NtAAC STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98-188 Construction for: Revisions: Mark Date By Qi Y-18-19 LANDLORD COMMENTS Q 2-2B-20 BMLD W 6 DEPARTMENT COMMENTS 0 A Architect / Engineer of Record Michael Ramos, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 EXPIRES 12031 Architect / Engineer lob No.: 029 N•xtore Store Design Revlslon No.: 05 NumberPc1 79779 Brand Design TYPe: LC.05 ISSUED FOR: 1 Construction Title ELECTRICAL POWER/SYSTEMS PLAN Date 12-9-19 Drawn By STAFF Checked By MPR 9teet E201 DEMOLITION AREA EXIT #2 0 C Q EXIT #2 t` 0 CD ADJACENT TENANT CUSTOJIIER AND EMPLO"EEAREA EXIT SIGNAG (TYR) C STOMER AND EMPLOYEE AREA MALL CORRIDOR DEMOLITION PLAN (PHASE IA) srwe MP. rr 00 CUSTOMER AND EMPLOYEE AREA IrpiaD I I- s LJ _ �. IL 1 Ti i I • • • • I 00 EGRESS PATH EXIT SIGNAGE (TYP.I CUSTOMER AND EMPLOYEE AREA ~I ) caw tY 0 V J EXIT #1 DEMOLITION AREA EXIT #1 tnatearfr s saaati cl**War •W SEA • • • ( CUSTOMER AND EMPLOYEE AREA 00 tite 4.. I II A> • .�.tatit e�• etl ,1" 'I 4 r NEW CONSTRUCTION PLAN (PHASE 2) VW. ra' INEW CONSTRUCT ION 2 16l EXIT #2 INEW CONSTRUCTION 1B Q INEW CONSTRUCTION 1C I NEW CONSTRUCTION PLAN (PHASE 1B AND IC) VS" •CC INEW CONSTRUCTION 3 EXIT SIGNAGE-7— (TYP.) NEW CONSTRUCTION PLAN (PHASE 3) ray 0( EXIT Si /^. 18 : 16 I `17 GENERAL NOTES 1. REFERENCE THE PHASING PLANS CREATED BY THE ARCHITECT FOR MORE SPECIFIC PROJECT INFORMATION. 2. PROVIDE CIRCUITS AS INDICATED. ALL CIRCUITS TO BE UNSWITCHED. WIRING METHOD TO BE REDUNDANT GROUND MC WHERE ALLOWED, OR REDUNDANT GROUND IN CONDUIT WHERE REQUIRED BY AH. ALL WIRING TO BE #12 AWG WITH GROUND. 3. ALL RECEPTACLES TO BE TAMPER RESISTANT, 20A RATED, WHITE WITH WHITE FACEPLATES. 4. COORDINATE WITH NEXTORE FOR LOW VOLTAGE DATA NEEDS PER ROOM, PER LOCATION. 5. WHERE REQUIRED, PROVIDE A/V DEVICE IN CIRCULATION AREA AND VISUAL ONLY IN EXAM AND PRE -TEST. CONNECT TO EXISTING SYSTEM. USE CEILING DEVICES. SUBMIT TO JURISDICTION FOR APPROVAL UTILIZE DEVICES COMPATIBLE WITH EXISTING SYSTEM. REUSE DEVICES WHEN THAT OPTION IS AVAILABLE. 6. ALL NOTES AND GENERAL CONTENT FROM THE ELECTRICAL PLANS SHALL APPLY TO THE PHASING CONSTRUCTION ARM AS APPLICABLE. @ KEY NOTES - ELECTRICAL PLAN 1. PROVIDE SELF CONTAINED TWO HEADED EMERGENCY BATTERY UNITS FOR EGRESS PATHS ESTABLISHED BY THE ARCHITECT PHASING PLANS FOR EACH PHASE. CONTRACTOR TO DETERMINE AND INSTALL SELF CONTAINED EBU'S AT A SPACING RATE OF ONE EBU PER 10' OF EGRESS PATH, OR TIGHTER AS REQUIRED BY LOCAL CODE OR AS REQUIRED BY THE AHJ. 2. EMERGENCY LIGHTING FOR THE EGRESS PATH FOR FINISHED PHASE AREAS SHALL BE AS SHOWN ON THE ELECTRICAL LIGHTING PLANS. IF REQUIRED BY THE AHJ, PROVIDE ADDITIONAL TEMPORARY EBU'S FOR ANY AREAS THAT DO NOT MEET CODE. REMOVE TEMPORARY EBU'S AFTER COMPLETION OF THE PROJECT. 3. PROVIDE A2L/A2LE OR G2L/G2LE FIXTURES (AS DETERMINED BY THE FIXTURE TYPES USED ON THE ELECTRICAL LIGHTING PLAN) FOR RECESSED 2X2 FIXTURES SHOWN ON THE CAPSULE PLAN. FIXTURES TO BE USED AS FINAL INSTALLED FIXTURES AT THE END OF UST Of THE TEMPORARY CONSTRUCTED CAPSULE AREA 4. WIRE CIRCUITS SHOWN TO A NEW 120V CIRCUIT IN THE PANEL FEEDING LOADS IN THIS AREA, OR TO A LOCAL RECEPTACLE CIRCUIT THAT HAS THE CAPACITY TO ADD THE LOAD IF SPACE IN THE PANEL DOES NOT EXIST. 5. SWITCHED WITH THE REMAINDER OF THE STORE LIGHTING. PROVIDE RELAY IF REQUIRED FOR DIFFERENT VOLTAGE CHARACTERISTICS. COORDINATE WITH PLANNING. THE EQUIPMENT MAY BE DIFFERENT THAN SHOWN. IF SO, OBTAIN POWER NEEDS FROM THE BRAND, VIA NEXTORE (TYR) REQUIREMENT CHANGES MY BE NEEDED PER CAPSULE LOCATION AND LAYOUT FOR EACH STORE. COORDINATE WITH NEXTORE. C5 ELECTRICAL - PHASING PLAN COMPUAI4Cf NFPA 0- O I :Z .Uu City of Tukwila tsUILDING DIVISION �• 46? I I fECEjVF;' 1TYCFIUIC ILA I MAR 0 5 20 PERMIT CENTER DESIGN ENGINEERING CONSIRUCTICN MANAGEMENT NEXTORE • .30C : c. "Iwt. Mr, Clr=`A. a1 .15133 ne-E000 e 1Crtnn COEt LW Gait, CT 06,26 .1 ;11543 0'3971:0 STORE #79779 SOUTHCENTER MALL SPACE #416 SEATTLE, WA 98188 Constructionr for: V JJ LL 0.g W19 lam .0 + , V O J t 13 U o Z�J WQ? J Revisions: Mark Date By Ain" LANDLORD COMMENTS A 2•n BUILDING DEPARTMENT COMMENTS A Architect / Engineer of Record Michael Romes, PE 2441 Crown Pointe Blvd Suamico, WI 54173 (920) 445-5007 Architect / Engineer Job No.: 029 Nextore Store Design Revision No.: 05 Neztore project Number 79779 Brand Design Type: LC.05 ISSUED FOR: ED Construction Title ELECTRICAL PHASING PLAN Date 12-9-19 Drawn By STAFF Chedted ey MPR Sheet E202