Loading...
HomeMy WebLinkAboutPermit D18-0372 - BOWLERO - INTERIOR RENOVATIONBOWLERO 100 ANDOVER PARK W 100 EXPIRED 08/31/2019 DI 8-0372 0 City of Tukwila Department of Community Development w 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 13 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: DEVELOPMENT PERMIT 0223000020 100 ANDOVER PARK W 100 Project Name: BOWLERO Permit Number: Issue Date: Permit Expires On: D18-0372 3/4/2019 8/31/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: OPEN FRAME LLC 14900 INTERURBAN AVE S #130 C/O JSH PROPERTIES INC, TUKWILA, WA, 98168 APRIL HOUSE 3617 SW CHARLESTON ST, SEATTLE, WA, 98126 HORIZON RETAIL CONSTRUCTION INC 1500 HORIZON DR, STURTEVANT, WI, 53177 HORIZRC072N5 BOWLERO 222 WEST 44TH ST, NEW YORK, NY, 10036 Phone: (206) 478-0844 Phone: (262) 638-6000 Expiration Date: 4/15/2019 DESCRIPTION OF WORK: INTERIOR ALTERATION OF APPROXIMATELY 50,806 SQ FT OF SINGLE STORY COMMERCIAL BOWLING CENTER. Project Valuation: $500,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $8,541.71 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date 3— 1-0 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signat Print Name: ,u) 1-iots� D 3-010-/9 Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 0 v 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 17: Maintain fire extinguisher coverage throughout. 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 24: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 22: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 21: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances 1 26: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 25: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 27: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 28: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 29: In other than Group 1-3, curtains, draperies, fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall comply with Section 807.4 and shall not exceed 10 percent of the specific wall or ceiling area to which they are attached. (IFC 807.1) Where required to exhibit improved fire performance, curtains, draperies, fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall be tested by an approved agency and meet the flame propagation performance criteria of Test Method 1 or Test Method 2, as appropriate, of NFPA 701 or exhibit a maximum rate of heat release of 100 kW when tested in accordance with NFPA 289, using the 20 kW ignition source. Reports of test results shall be prepared in accordance with the test method used and furnished to the fire code official upon request. (IFC 807.4) 30: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 31: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 32: Signs are not approved as part of this permit. A separate sign permit is required PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH/GYPSUM BOARD 0406 SUSPENDED CEILING 0601 WALL INSULATION CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov za.if Building Permit No. -- 0374 Project No. Date Application Accepted;, I I 'd7.400 Date Application Expires: 2 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 100 Andover Park W. Tenant Name: Bowlero PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Matt Ramos /4-pti/ iktice Address: 8370 Wilshire Blvd. #330 City: Beverly Hills State: CA Zip: 90211 Phone: (310) 275-7774 / Fax: Jot f-79t(y Email: Matt@Permitadvisors.com/ GENERAL CON'1;RACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: King Co Assessor's Tax No.: Suite Number: #100 Floor: New Tenant: ❑ Yes ❑ ..No ARCHITECT OF RECORD Company Name: CallisonRTKL, Inc. Architect Name: Ho Cheuk Coi Address: 233 Broadway, 16th floor. City: New York State: NY Zip: 10279 Phone: (212) 354-9240 Fax: Email: Bowlero@crtkl.com ENGINEER OF RECORD Company Name: Henderson Engineers, Inc. Engineer Name: Matt Kolins Address: 8345 Lenxa Drive, Ste 300 City: Lenexa State: KS Zip: 66214 Phone: (913) 742-5681 Fax: Email: Matt.Kolins@hendersonengineers.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: -r& 0 LL le, v.0 Address: 7_ 2.2 W S4 Sf City: / L)ei,) Yov4 State: All'q Zip: /01)3o BUILDING PERMIT INFORMATI- 206-431-3670 Valuation of Project (contractor's bid price): $ 500,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Interior Alteration of approximately 50,806 sqft of single story commercial bowling center. Will there be new rack storage? ❑ Yes 1.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 50,806 50,806 0 Mixed occupancy See attached. 2"d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling:_ Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: .F Sprinklers a Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑'' Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. PUBLIC WORKS PERMIT INF TION — 206-433-0179 Scope of Work (pleaseprovide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila 0 ...Sewer Use Certificate 0 .. Highline ❑ ... Valley View ❑ .. Renton ❑...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond 0 .. Insurance 0 .. Easement(s) 0 .. Maintenance Agreement(s) 0 ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer 0 .. Abandon Septic Tank ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities 0 .. Curb Cut 0 .. Channelization ❑ ...Frontage Improvements 0 .. Pavement Cut 0 .. Trench Excavation ❑ ...Traffic Control 0 .. Looped Fire Line 0 .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection Irrigation " Domestic Water " ❑ ...Permanent Water Meter Size... 19 WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size 5> WO # 0 ...Deduct Water Meter Size " ❑ ...Sewer Main Extension Public 0 Private ❑ ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) O ...Water 0 ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State Zip PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 11/20/2018 Print Name: Matt Ramos Day Telephone: (310) 275-7774 Mailing Address: 8370 Wilshire Blvd. #330 Beverly Hills CA 90211 City State Zip Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $8,541.71 D18-0372 Address: 100 ANDOVER PARK W 100 Apn: 0223000020 $8,541.71 DEVELOPMENT $8,291.22 PERMIT FEE R000.322.100.00.00 0.00 $5,009.83 PLAN CHECK FEE R000.345.830.00.00 0.00 $3,256.39 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $250.49 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15892 R000.322.900.04.00 0.00 $250.49 $8,541.71 Date Paid: Monday, November 26, 2018 Paid By: PERMIT ADVISORS INC Pay Method: CHECK 9658 1w c City of Tukwila Department of Community Development 6/28/2019 APRIL HOUSE 3617 SW CHARLESTON ST SEATTLE, WA 98126 RE: Permit No. D18-0372 BOWLERO 100 ANDOVER PARK W - SUITE 100 Dear Permit Holder: Allan Ekberg, Mayo) Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/31/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/31/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Si erely, 4,J/cc ° Alt Kandace Nichols Permit Technician File No: D18-0372 c PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0372 PROJECT NAME: BOWLERO SITE ADDRESS: 100 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # Revision # DATE: 11/26/18 before Permit Issued after Permit Issued DEPARTMENTS: A-) AUC A-tA tilvc V-10--tf Building Division WI Public Work Fire Prevention 11111 M4rp,ierw Planning Division Structural Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/27/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 12/25/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: 0 Itoine Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries A-Z Index Help My Uzi Workplace Rights Trades & Licensing HORIZON RETAIL CONST INC Owner or tradesperson Principals HENDERSEN, JON E GUSTIN, ROBERT L HENDERSON, JON E JAWORT, DAN, AGENT Doing business as HORIZON RETAIL CONST INC WA UBI No. 601 483 044 1500 HORIZON DRIVE STURTEVANT, WI 53177 262-638-6000 Business type Corporation Governing persons ROBERT L GUSTIN JON E HENDERSEN; PATRICK J CHRISTENSEN; PAT CHRISTENSON; JON E HENDERSEN; ERIC NIEDEFFER; TOM SCHAEFER; DAN SIUDAK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HORIZRC072N5 Effective — expiration 08/25/1993— 04/15/2019 Bond HANOVER INS CO Bond account no. 1592447 $12,000.00 Received by L&I Effective date 04/15/2002 04/10/2002 Expiration date Until Canceled Insurance Zurich American Ins Co $1,000,000.00 Policy no. 5919211 F Expiration date 03/29/2019 Insurance history Savings .................. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 18-2-26268-2KNT Complaint filed by SCOTT COATINGS LLC Dismissed Complaint against bond(s) or savings 1592447 Complaint date Complaint amount 11/07/2018 $79,487.20 L&I Tax debts No L&j tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. NJON B01457 Issue date 10/02/2017 Violation city STURTEVANT Type of violation CONSTRUCTION INFRACTION Description Subcontracting to or using an unregistered contractor. Satisfied RCW/WAC 18.27.200(1)(e) RCW Violation amount $1,000.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 861,958-00 Doing business as HORIZON RETAIL CONSTRUCTION Estimated workers reported Quarter 4 of Year 2018 "4 to 6 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes This contractor received a valid strike(s) for violation or infraction for the following L&I law(s). Learn more about contractor strikes. RCW Violation 18.27.200 Description Failure to comply with contractor registration requirements, per RCW 18.27 Contractors not allowed to bid No debarments have been issued against this contractor. Effective Date 9/24/2009 Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/06/2018 Inspection no. 317948086 No violations 17261 Southcenter parkway Tukwila, WA 98188 0 L; rf) Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. ABBREVIATIONS DRAWING INDEX 1 ) / / / / / /------------- /'---- 7-"" / 1 / ,' / /// / / / /ni / I / 7 / i / / i / / / 1 ,,,// / \..__-, / AC ASPHALTIC CONCRETE ACC ACCESSIBLE ACP ACOUSTICAL CEILING PANEL ACST ACOUSTICAL AD AREA DRAIN ADDM ADDENDUM ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT ALT 'ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE APT APARTMENT ARCH ARCHITECT, ARCHITECTURAL AUTO AUTOMATIC AV AUDIO VISUAL AWP ACOUSTICAL WALL PANEL(S) BB BULLETIN BOARD BD BOARD BLDG BUILDING BLKG BLOCKING BO BOTTOM OF BOT BOTTOM BRG BEARING BRZ BRONZE BSMT BASEMENT BUR BUILT UP ROOFING CAB CABINET CB CATCH BASIN CEM CEMENT, CEMENTMOUS CER CERAMIC CG CORNER GUARD CH COAT HOOK CI CAST IRON CJ CONTROL JOINT CIP CAST -IN -PLACE CL CENTERLINE CLG CEILING CLO CLOSET CLR CLEAR CMU CONCRETE MASONRY UNIT CO CLEAN OUT, CASED OPENING COL COLUMN COMM COMMUNICATION CONC CONCRETE CONN CONNECTION, CONNECT CONSTR CONSTRUCTION CONT CONTINUOUS, CONTINUE CORR CORRIDOR CPT CARPET CSWK CASEWORK CTR CENTER CU CUBIC D DEEP, DEPTH DBL DOUBLE DEMO DEMOLISH, DEMOLITION DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIAGRAM DIM DIMENSION DIV DIVIDE, DIVISION DMPF DAMPPROOF, DAMPPROOFING DN DOWN DR DOOR, DRESSING ROOM DS DOWNSPOUT OW DISHWASHER DWG DRAWING DWR DRAWER E EAST EIFS EXTERIOR INSULATION AND FINISH SYSTEM EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRIC, ELECTRICAL ELEV ELEVATOR ENCL ENCLOSE, ENCLOSURE EP ELECTRIC PANEL EQ EQUAL EQUIP EQUIPMENT ESCAL ESCALATOR EXH EXHAUST EXP EXPANSION, EXPOSED EXIST EXISTING FA FIRE ALARM FCIO FURNISHED BY CONTRACTOR/ INSTALLED BY OWNER FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDTN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET EH FIRE 1I FHC FIRE HOSE CABINET FIG FIGURE FIN FINISH, FINISHED FLEX FLEXIBLE FLR FLOOR, FLOORING FLUOR FLUORESCENT FO FACE OF, FINISHED OPOWNER/ENING FDIC FURNISHED BY INSTALLED BY CONTRACTOR FP FIRE PROTECTION, FIREPROOF FR FRAME, FIRE FRMG FRAMING RATED FRT FIRE RETARDANT TREATED FT FOOT, FEET FTG FOOTING FUT FUTURE P/C FIRE HOSE VALVE CABINET FWC FABRIC WALL COVERING FWP FABRIC WRAPPED PANEL(S) GA GAGE GALV GALVANIZED GEN GENERAL GENERATOR GFRC GLASS -FIBER REINFORCED CONCRETE CMG GLASS -FIBER REINFORCED GYPSUM GFRP GLASS -FIBER REINFORCED PLASTIC GL GLASS GYP GYPSUM GYP BD GYPSUM BOARD H HIGH HB HOSE BIBB HC HOLLOW CORE HD HAND DRYER HDBD HARDBOARD HOW HARDWARE HDWD HARDWOOD HM HOLLOW METAL HO HOLD OPEN HORIZ HORIZONTAL HR HOUR Frr HEIGHT HVAC HEATING V8NITLATING MD Ali CONMTIffilt 1 - . ' r il • 1. VW- D NCL NFO NSUL NT WD JAN JT KIT L LAM LAU LAV LT LTG MAS MAIL MAX MECH MED MEMB MELZ MGT MFR MH MIN MISC MO MS MTD MR_ MVBL N NIC NO NOM NTS OC OH OD OPNG OPP ORD OTS PBD PRCST PD PERP PLAM PLAS PLYWD PNL PL PR PRKG PROP PT PTN R RCP RD REF REF REINF REQD REV RFG RM RO RT S SC SCHED SD SECT SGL SHT SHTHG SIM SPEC SPKLR SPKR SQ SS SST STC STD STL STOR STRUCT SUSP T T&G TEL TEMP TER THK TMPD TO TSTAT TV TYP UGND UNFIN UON vERT VEST VNR VR VWC W W/ W/O WC WD WH WP WR WT WWF XFMR NSIDE DIAMETER NCLUDE, INCLUDING NFORMATION NSULATE, INSULATION NTERIOR NDIRECT WASTE DRAIN JANITOR JOINT KITCHEN LONG LAMINATE, LAMINATED LAUNDRY LAVATORY UGHT LIGHTING MASONRY MATERIAL MAXIMUM MECHANICAL MEDIUM MEMBRANE MEZZANINE MANAGEMENT MANUFACTURE, MANUFACTURE MANHOLE MINIMUM, MINUTE MISCELLANEOUS MASONRY OPENING MOP SINK MOUNTED METAL MOVABLE NORTH NOT IN CONTACT NUMBER NOMINAL NOT TO SCALE ON CENTER OVERHEAD OUTSIDE DIAMETER OPENING OPPOSITE OVERFLOW ROOF DRAIN OPEN TO STRUCTURE ABOVE PARTICLEBOARD PRECAST PLANTER DRAIN PERPENDICULAR PLASTIC LAMINATE PLASTER PLYWOOD PANEL PROPERTY LINE PAIR PARKING PROPERTY PAINT, POINT, PRESSURE TREATED PARTITION RADIUS, RISER REFLECTED CEILING PLAN ROOF DRAIN, ROAD REFER TO, REFERENCE REFRIGERATOR REINFORCED, REINFORCING REQUIRED REVISED, REVISION ROOFING ROOM ROUGH OPENING RIGHT SOUTH SOLID CORE SCHEDULE STORM DRAIN SECTION SINGLE SHEET SHEATHING SIMILAR SPECIFICATION SPRINKLER SPEAKER SQUARE SERVICE SINK STAINLESS STEEL SOUND TRANSMISSION CLASS STANDARD STEEL STORAGEVVVV STRUCTURAL SUSPENDED TREAD TONGUE AND GROOVE TELEPHONE TEMPERATURE, TEMPORARY TERRAllO THICK, THICKNESS 'TEMPERED TOP OF THERMOSTAT TELEVISION TYPICAL UNDERGROUND UNFINISHED UNLESS OTHERWISE NOTED VERTICAL VESTIBULE VENEER VAPOR RETARDER VINYL WALLCOVERING WEST, WIDE WITH WITHOUT WATER CLOSET, WALLCOVERING WOOD WALL HYDRANT WEATHERPROOF, WATERPROOF, WATERPROOFING, WORK POINT WATER RESISTANT WEIGHT WELDED WIRE FABRIC TRANSFORMER SHE O. SHEET TITLE ISSUED FOR PERMIT ARCH CTURAL T-001 TITLE SH G-00 G NOTES • G 002 ACCESSIBIUTY D A-010 D OLMON PLAN A-100 CONSTRUCTION P • \ A-200 REFIICTED COUNG PLAN • 7 ----- .____----7 A- 0 POWER AND DATA P • ///n / / I / 0 C: A-600 DOOR SCHEDU D DET LS • / / I 0 A-700 IOR A ONS I / 1 ; / NJ I 0 0 ANDOVER TUKVVILA PARK WA 98188 W, PROJECT DIRECTORY Art VICINITY MAP I IT CLIENT: MEP ENGINEER: ... '',i1?-5,,WW.:33,- II' 1 , -07-3r- ', i i' \ at.„-73 ' , • „ BOWLERO HENDERSON ENGINEERS, INC. LESUE O'HARA MATT KOUNS , '.7,. IN - 1, ' - . I, . . 1, 3- A 4, ''''' S ''''''''''. ' ' ' ' -. ' ''''',':„ ....4.v ' ii --ter- , ...-.-1Titen 7 222 WEST, 44TH STREET 8345 LEND(A DRIVE SUITE 300 NEW YORK, NY 10036 LENEXA, KS 66214 „` "•3, -;.7.- , , 14°' "'" 1.- ,"' ,,,0-14,v ,,_ , j ,,,, _ , Yr" TEL 817.937.5860 TEL 913.742.5681 EMAIL LOHARAOBOWLEROCORP.COM EMAIL MATT.KOUNSOHENDERSONENGINEERS.COM V V „,,i i.-V hi - ARCHITECT OF RECORD:, GENERAL CONTRACTOR: V ' ______ , , -,, - , ,_ „ „ 1 I -' . „„....',.._ .1 CAWSONRTKL, INC. TBD SIGNING PRINCIPAL: TODD ENOKI 1420 FIFTH AVE STE 2400 SEATTLE, WA 98101 CONTACT: . ., V 3 . r P- c Vc'' : ; 7-.--- - _ -7_73,-41, =..-:ii _ 1 --__ sot rricemer I, „... ; _, (73 -I ' 1 100 Andover a., 1,,sirk W ',.,= ---- ----- '-'' -- - -_-1-1 ''''S''---------- - 5, .. DAVID ASFOUR/HO CHEUK CHOI - -Sakrr_skid ..,:- BakerBlvd THE WOOLWORTH BUILDING 233 BROADWAY, 16TH FLOOR ' '- '17,..' ___ _ :f 17 - / I' NEW YORK, NY 10279 TEL 212.354.9240 EMAIL BOWIEROOCRTKLCOM , '',_0". in ,--,i I ,,, .--='! L-3-3.7,---, =-.. :',1111'-'1:'," i I q. ....,.t. -'-7,-= ----i I. I - -1 _ _ ,r : '- 1 - I , ,,_:,, --. B'I ork--5,-"" Ice,,1 ,..: - i in ''._,_-_„-t II, 1 ' ). I , I , --- . stiihVii-Brid Straride, r_Blvd --- - 3„. '4..' ig' V 0 74 ....., ,,,,i, , 1,. - ---- , - 3 V ''.'"A BUILDING CODE CRITERIA SCOPE OF WORK KEY PLAN III,ih_,r . t; - --, . . JURISDICTION: CITY OF TUKWILA, VA INTERIOR ALTERATION OF APPROXIMATELY 50,806 SQFT OF SINGLE STORY COMMERCIAL BOWLING CENTER. SCOPE OF WORK TO INCLUDE: . ,,_, -: • .V V '',.7 , , .., ' . ", 10 NAME & ADDRESS: BOWLER() LANES 100 ANDOVER PARK W #100, 1. INSTALLATION OF NEW NON -LOAD BEARING PARTITIONS 2. NEW MILLWORK 3. NEW POWER DATA V . , V _.. VVV V TUKWILA, WA 98188 4. EXTERIOR SIGNAGE 5. NEW ARCADE LAYOUT ' 7'7" , . : -4'4' ' i PARCEL ID: 022300-0020 .. A r : i - ,-- , - - - ZONING DISTRICT: LTUC-RC (TUC) LANDMARK STATUS: NO LANDMARK _,......J r-? ..z..1",...,4 , , it _ , ,,,. ,* ',., , ! ALE; S. : 201.3„. _ - . - -, . A. -A, AREA OF WORK - . ' _. . .„, SQUARE FOOTAGE: 50,806 SOFT . .. . OCCUPANCY TYPE: A-2, A-3, B, M, S-1, S-2 PROJECT DESCRIPTION: (NO CHANGE IN USE) - ADDITION TO EXISTING FACILITY CONSTRUCTION TYPE. TYPE III -A , V .._ , SPRINKLER: EXISTING TO REMAIN 1 FIRE TO 'V . ALARM SYSTEM: EXISTING REMAIN , , V BUILDING CODE CRITERIA: 2015 INTERNATIONAL BUILDING CODE WITH AMENDMENTS ACCESSIBILITY CODE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN PLUMBING CODE 2015 UNIFORM PLUMBING CODE , ' ' ---- - , ''' 100 ANDOVER PARK W #100 , TUKWILA, WA 98188 50,806 SOFT MECHANICAL CODE 2015 INTERNATIONAL MECHANICAL CODE (IMC) WITH AMENDMENTS ' FA. , 4,14I.1 . ,..., ,41,.a.:m ' - .. 1. .---. „,, , , 1 STORY ELECTRICAL CODE. NFPA 70 NATIONAL ELECTRICAL CODE . ENERGY CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) WITH AMENDMENTS , FIRE CODE 2015 INTERNATIONAL FIRE CODE (IFC) WITH AMENDMENTS r MAXIMUM TRAVEL DISTANCE 250' MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE: 75' ' 3' -,,' . „ , -' .. „ - .,• I „ , ' - . _ . , .. „... . LIFE SAFETY/EGRESS CALCULATIONS (TABLE 1004.1.21 , ' ' 4,-.. - , . _ . FUNCTION OF SPACE: OCCUPANCY OCCUPANT LOAD FACTOR: TOTAL SF: OCCUPANT TOTAL: ., ,.. . CIRCULATION - - 7,215 SF - BOWLING LANES (40 LANES) A-3 5 PER LANE 28,925 SF 200 GENERAL NOTES ARCADE (UNCONCENTRATED) A-3 15 GROSS 2,030 SF 135 1. DIMENSIONS TAKE PRECEDENT OVER SCALE. , EVENT ROOM (UNCONCENTRATED) A-3 15 GROSS 668 SF 45 2. FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE WORK. - FILE COPY KIDS ROOM (DAY CARE) A-3 35 GROSS 603 SF 18 VERIFY 3. THE CONTRACT DOCUMENTS, WHICH INCLUDE THE AGREEMENT, THE GENERAL CONDMONS, DRAWINGS, AND SPECIFICATIONS, ARE REVISIONS Permit No. 1)19- OS*7 2 LOUNGE/DINING AREA A-2 15 GROSS 3,868 SF 258 KITCHEN A-2 200 GROSS 3,386 SF 17 SHOP/MERCANTILE M 60 GROSS 348 SF 6 COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UNLESS OTHERWISE INDICATED. sub NO changes snall be made to tne scot* of work without prior approval of the Tukwila Building Division. o NOTE: Revisins led! require a new plan mittal and may include additional plan review PsiaonnsreAvieppwroavPaPi oinsnssatrutub::iocylnalcioocue::eci omis:Mors not authorize the vriiifvacclatii ordinance Receipt of approved Field Copy and ndiho Ii=ledge By. ....04. //Cr FRONT DESK/MERCANTILE 15 CI GROSS 58 SF 1 5. DOORS AND CASED OPENINGS INDICATED NEARBY WALL INTERSECTIONS SHALL BE LOCATED SO THAT THE EDGE OF THE FINISH OPENING IS 6 Date: OTHERWISE INDICATED. ALL OTHER DOORS AND CASED OPENINGS SHALL BE CENTERED INCHES FROM THE FACE OF THE NEARBY WALL UNLESS OBETWEEN ADJACENT WALL INTERSECTIONS. City of Tukwila BUILDING DIVISION OFFICES/BUSINESS B 100 GROSS 858 SF 9 STORAGE S-1 300 GROSS 3,846 SF 13 MECHANICAL S-2 300 GROSS 794 SF 3 6. ITEMS INDICATED AS BIDDER DESIGNED SHALL BE DESIGNED AND ENGINEERED BY THE CONTRACTOR AND/OR SUBCONTRACTOR IN COMPLIANCE WITH APPLICABLE LEGAL REQUIREMENTS, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BY A QUALIFIED PROFESSIONAL ENGINEER, USING PERFORMANCE AND DESIGN CRITERIA INDICATED AND SUBJECT TO SUBMITTAL REVIEW BY THE ARCHITECT. RESTROOMS N/A 1,246 SF N/A 7. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, ORDINANCES AND STANDARDS HAVING JURISDICTION. ANY QUESTIONS OR CONFLICTS CONCERNING COMPLIANCE WITH THESE SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. SEPARATE PERMIT REOUIRED.FOR: TOTAL OCCUPANCY: 705 NUMBER OF EXITS OR ACCESS TO EXITS PER STORY MINIMUM: (TABLE 1018.1) 3 NUMBER OF EXITS OR ACCESS TO EXITS PER STORY PROVIDED: 9 TOTAL EGRESS WIDTH REQUIRED 0 0.20° PER OCCUPANT (TABLE 1029.6.2): 141° TOTAL EGRESS PROVIDED 9 DOORS 0 36° CLEAR OPENING: 324° 8. THE GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXISTING SITE CONDITIONS PRIOR TO SUBMITTING REQUESTS FOR INFORMATION, SHOP DRAWINGS, PRODUCT INFORMATION, ETC. 9. ALL MATERIALS SHALL BE FURNISHED NEW UNLESS OTHERWISE NOTED. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTIVE MATERIALS AND WORKMANSHIP FOR A MINIMUM PERIOD OF ONE (1) YEAR OR AS SPECIFIED, WHICHEVER IS GREATER, AFTER THE DATE OF SUBSTANTIAL COMPLETION OR FINAL ACCEPTANCE OF WORK. UV Mechanical Div Electrical ar Plumbing I:1, Gas Piping . BUILDING DIVISION PLUMBING FIXTURE CALCULATIONS (TABLE 2902.1) 10. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED RECOMMENDATIONS FOR SERVICES INTENDED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, COLLAPSE, MISALIGNMENT ACCORDING TO APPLICABLE CODES, STANDARDS, AND STANDARD CONSTRUCTION PRACTICES. OCCUPANCY OCCUPANT TOTAL MALE W.C. FEMALE W.C. MALE !AV. FEMALE LAV. 12. THE CONTRACTOR SHALL PROVIDE UPDATED RECORD DOCUMENTS OF AS -BUILT CONDITIONS OF SITE UPON COMPLETION OF CONSTRUCTION. REVIEWED FO R CODE COMPLIANCE A-3 398 3.19 6.13 1.99 1.99 A-2 275 3.66 3.66 1.38 1.38 M 7 0.01 0.01 0.01 0.01 B 9 0.36 0.36 0.23 0.23 13. THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE, FIREPROOFING, AND FIRE RATING OF THE ENTIRE BUILDING. 14. SEE ENGINEERING DRAWINGS FOR SCOPE OF WORK OF ASSOCIATED SYSTEMS. WHERE MECHANICAL ELECTRICAL, OR PLUMBING DEVICES ARE REMOVED, ALL PIPING AND/OR CONDUITS THAT ARE ABANDONED SHALL BE CAPPED OFF BELOW THE FLOOR, INSIDE WALLS, OR ABOVE CEILINGS EXCEPT WHERE NOTED OTHERWISE. ELECTRICAL AND MECHANICAL CONTRACTORS TO REMOVE ALL UNUSED WIRING TO PANEL BOXES, PATCH AND REPAIR FINISHES TO MATCH ADJACENT SURFACES. HAZARDOUS CONSTRUCTION, THE IMMEDIATELY FOR PLANNING APPROVED • No changes can be made, to these plans without approval from the Pl7 anning Division Of DCD Approved /V\ 3:xtli-v •.APPROVED - DEC 17 2018 A-- litit City of Tukwila BUILDING DIVISION S 16 0.16 0.16 0.16 0.16 15. UPON DISCOVERY OF MATERIALS ENCOUNTERED DURING NOTIFY ARCHITECT AND OWNER By: FURTHER INSTRUCTIONS FOR THE AFFECTED AREA. THE WORK AREA AFFECTED SHALL BE COMPLETELY SEALED OFF DURING ABATEMENT. Date: 0.----7-trij - . ' . TOTAL 705 7.38 10.32 4.14 4.14 WATER CLOSET MENS REQUIRED: 8 WATER CLOSET MENS PRONDED: 7 (2 ADA) + 6 URINALS = 13 WATER CLOSET WOMENS REQUIRED: 11 WATER CLOSET WOMENS PROVIDED: 11 (2 ADA) LAVATORIES REQUIRED PER SEX: 5 PER SEX LAVATORIES PROVIDED PER SEX: 6 1 SERVICE SINK PROVIDED. - 414) t (6 es 0 CITY OF l'UKWILA NOV 2 6 2018 PERMIT CENTER 4714 1.. a CALLISORTKI: CallisonRTKL, Inc. The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 Tel: 212.354.9240 Fax: 212.354.9253 CallisonRTKL Project No: 003-160285.00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817.938.5860 www.bowlero.com Consultant Henderson Engineers, Inc. 8345 Lenexa Drive Suite 300 Lenexa, KS 66214 Tel: 913.742.5000 www.hei-eng.com Issued for Permit Client/Owner/Project Address Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Project Address 100 Andover Park W #100, Tukwila, WA 98188 Issue Drawing Log 11/09/2018 ISSUED FOR PERMIT Seal TERED ITECT ENtKI ASHINGTON Sheet Identification TITLE SHEET T-001 PARETAILWYCIBOMER0164-PROJECTS1TUKWILA, WA11.4 ARCHITECTURE12-CADIA-CONTRACT DRAWINGS1NEW SHEETS 1113/2016 3:59:29 PM © 2016 CallisonRTKL Inc. GENERAL NOTES & CONDITIONS CONSTRUCTION PLAN NOTES (CONT.) FURNITURE PLAN NOTES GENERAL NOTES LIGHTING NOTES (CONT.) CALL S RTKI: 1.1 BASE BUILDING CONSTRUCTION SPECIFICATIONS & THE TENANT LEASE AGREEMENT SHALL GOVERN WORKMANSHIP/MATERIALS/DESIGN, EXCEPT AS THESE VARIOUS ELEMENTS WHICH COULD BE MODIFIED OR AMENDED BY THESE CONSTRUCTION DOCUMENTS (CD, HEREAFTER). ANY NOTE OR INDICATION SHOWN OR IMPLIED WHICH DOES NOT CONFORM TO THE LETTER OR SPIRIT, SO DEFINED, SHALL BE BROUGHT TO THE ATTENTION OF THE CLIENT & THE ARCHITECT, IN WRITING, FOR REVIEW. 1.2 THE GENERAL CONTRACTOR (GC, HEREAFTER) UPON SIGNING THE OWNER/GC AGREEMENT, ACCEPTS THE CD (INCLUDING THESE DRAWINGS W/THE INCLUDED NOTES & DESCRIPTIVE MATERIAL) & AGREES TO EXECUTE THE NECESSARY WORK IN MANNER DESCRIBED THEREIN. A. UPON EXAMINATION/FAMILIARIZATION OF CD & JOB SITE VISIT, ANY DISCREPANCIES, OMISSIONS, AMBIGUITIES AND/OR CONFLICTS NOTED SHALL BE BROUGHT TO THE ATTENTION OF THE CLIENT 8c THE ARCHITECT IN WRITING, FOR CORRECTION. B. ANY ELEMENT, WHATSOEVER, REQUIRED BY BUILDING TO BE INCORPORATED IN CONSTRUCTION BUT NOT SPECIFIED IN CD SHALL BE BROUGHT TO ATTENTION OF THE CLIENT & THE ARCHITECT FOR REVIEW/ACTION. C. NO MODIFICATIONS/REVISIONS/CHANGES SHALL BE UNDERTAKEN UNLESS SPECIFICALLY SO INSTRUCTED & APPROVED BY THE CLIENT & THE ARCHITECT. D. DURING COURSE OF PROJECT, THE CLIENT 8c THE ARCHITECT SHALL MAKE EVERY EFFORT TO FULLY INFORM ALL CONCERNED PARTIES REGARDING DECISIONS/ACTIONS TAKEN WHICH, IN ANY WAY, MIGHT AFFECT ANY SAID PARTIES. 1,3 EXCEPT AS MAY OTHERWISE BE INDICATED, THE GC SHALL PROVIDE & PAY FOR ALL MATERIALS, LABOR, ALL OTHER ITEMS/SERVICES NECESSARY TO ACCOMPLISH, ENTIRELY, THE WORK SET FORTH IN THESE CD. A. UNLESS OTHERWISE SPECIFIED, ALL MATERIALS SHALL BE NEW 8c BOTH MATERIALS 8c WORKMANSHIP SHALL BE OF QUALITY CONSISTENT W/THAT EXPECTED FOR A CLASS "A" INSTALLATION. B. ANY WORK NEEDED TO BE ACCOMPLISHED ON AN OVERTIME BASIS SHALL BE PRICED AND PRESENTED AS SUCH IN BID. C. ALL WORKMEN & SUBCONTRACTORS SHALL BE SKILLED IN THEIR TRADES. D. ANY & ALL GOVERNING LOCAL LABOR LAWS, REGULATIONS 8c REQUIREMENTS AND THOSE SET AS BUILDING REQUIREMENTS SHALL BE OBSERVED & FOLLOWED AS THEY RELATE TO THIS PROJECT. ARRANGEMENTS FOR COMPLIANCE W/THESE REQUIREMENTS SHALL BE MADE BY GC TO PRECLUDE ANY LABOR -RELATED JOB DISPUTES & RELATED DELAYS/PROBLEMS/& COSTS. 1.4 GC SHALL SUBMIT JOB SCHEDULE TO THE CLIENT & THE ARCHITECT AT TIME OF PRICING/BID SUBMISSION. PRICING -SHALL BE IN A COMPLETE BREAKDOWN FORM, LISTING WORK NOT ONLY BY VARIOUS TRADES, BUT ALSO WITH MAJOR SUB CATEGORIES WITHIN EACH TRADE ITEMIZED. 1.5 GC SHALL BE RESPONSIBLE FOR SECURING THE CLIENT SPACE DURING CONSTRUCTION FOR PROTECTION OF MATERIALS, TOOLS, ETC. WITHIN. A. SAFE CONSTRUCTION PRACTICES SHALL BE OBSERVED TO ASSURE WORKMEN'S SAFETY ON JOB AND SAFETY OF ALL PERSONNEL OUTSIDE THE CLIENT SPACE. B. GC SHALL PRESENT PROOF OF INSURANCE COVERING IN AMOUNTS REQUIRED BY LOCAL LAW, AS STIPULATED BY BUILDING, AND AS REQUIRED BY THE CLIENT. PROOF OF INSURANCE SHALL BE TO CONSTRUCTION. CERTIFICATES, ETC., SHALL BE PRIOR SUBMITTED TO THE CLIENT AND BUILDING AVAILABLE AT JOBSITE FOR EXAMINATION ON DEMAND. 1.6 GC SHALL BE RESPONSIBLE FOR PROTECTING THE CLIENT DEMISED PREMISES AND ALL AREAS, CORRIDORS, STAIRS, ELEVATORS, ETC. OUTSIDE THE CLIENT SPACE, AGAINST DAMAGE DURING THE CONSTRUCTION PROCESS. ANY DAMAGE TO THESE AREAS SHALL BE CORRECTED TO SATISFACTION OF THE CLIENT AND THE BUILDING AT THE GC'S COST. 1.7 GC SHALL PERMIT AND FACILITATE OBSERVATION OF WORK BY BUILDING, THE CLIENT THEIR AGENT AND PUBLIC AUTHORITIES, AT ALL TIMES, AS REQUESTED OR NEEDED, 1.8 OWNER RETAINS THE RIGHT TO LET OTHER CONTRACTORS IN CONNECTION WITH THE PROJECT WORK. GC SHALL PROPERLY COOPERATE, COORDINATE AND INTERFACE THEIR SCHEDULE WITH ANY SUCH CONTRACTOR VENDORS, ETC. 1.9 HVAC SYSTEM ENGINEERING/DESIGN FOR THIS PROJECT SHALL BE PROVIDED BY ENGINEERING FIRM APPROVED BY BUILDING. 1.10 GC SHALL BE RESPONSIBLE FOR CONFORMANCE WITH ANY APPLICABLE LOCAL BUILDING CODES AND SHALL NOT KNOWINGLY EXECUTE WORK SPECIFIED WHICH IS NOT IN CONFORMANCE. 1.11 GC SHALL RE -EXECUTE ANY WORK THAT FAILS TO CONFORM TO THE DRAWINGS/DETAILS AS DEFECTS DUE TO FAULTY MATERIALS OR WORKMANSHIP WHICH APPEAR WITHIN A ANY SHOWN, AND PERIOD OF ONE (1) YEAR FROM THE DATE OF MOVE -IN. 1.12 WARRANTY SHALL BE EXTENDED FOR ALL CONSTRUCTION COMPONENTS AND EQUIPMENT AND INSTALLATIONS INCLUDED IN THIS WORK FOR A MINIMUM OF 1 YEAR FROM DATE OF SUBSTANTIAL COMPLETION. 1.13 SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT IN TRIPLICATE FOR REVIEW. SHOP DRAWINGS ENHANCE THESE SPECIFICATIONS; APPROVAL OF SHOP DRAWINGS SHALL NOT RELEASE CONTRACTOR OF RESPONSIBILITY FOR WORK AS SPECIFIED. 1.14 CONDITION AND USE OF THE JOB SITE SHALL BE THE RESPONSIBILITY OF THE GC. JOB SITE SHALL BE MAINTAINED IN A CLEAN AND ORDERLY FASHION. DEBRIS AND TRASH FOR ALL TRADES AND CONTRACTORS UNDER GC CONTROL AND FOR THOSE UNDER DIRECT CONTRACT WITH OWNER SHALL BE REMOVED DAILY. GC SHALL COORDINATE DELIVERIES, INSPECTION, SITE VISITS FOR ALL TRADES AND CONTRACTORS AS REQUIRED. 1.15 FINAL CLEANING AT SUBSTANTIAL COMPLETION SHALL INCLUDE CLEANING OF ALL FINISHED WOOD AND GLASS SURFACES; DUSTING OF ALL HORIZONTAL SURFACES, VACUUMING OF ALL CARPETED AREAS AND REMOVAL OF ANY SPOTS, STAINS, SPILLS, ETC. ON ANY SURFACE, INCURRED DURING THE CONSTRUCTION PERIOD. 1.16 SPECIAL REQUIREMENTS: THE FOLLOWING ADDITIONAL LABOR SHALL BE PROVIDED BY GC FOR WORK TO BE DIRECTED BY OWNER TO FACILITATE OCCUPANCY: A. JOB SITE CLEANUP SPECIFIED IN 1.14 SHALL CONTINUE BEYOND DATE OF SUBSTANTIAL COMPLETION TO MOVE -IN DAY AND SHALL INCLUDE REMOVAL OF ACCUMULATED DEBRIS RESULTING FROM WORK BY TELECOMMUNICATIONS CONTRACTORS AND OTHER VENDORS UNDER CONTRACT TO THE CLIENT (NOTE: FURNITURE PACKING MATERIALS WILL BE REMOVED BY FURNITURE INSTALLER.) 2.16 HARDWARE SHALL BE PROVIDED BY GC AS SPECIFIED. SEE MILLWORK DETAILS AND NOTES FOR SCOPE OF WOODWORKING AND HARDWARE. 2.17 ALL SUBSTITUTIONS, I.E., "EQUALS" MUST BE SUBMITTED TO THE CLIENT PROJECT MANAGER FOR WRITTEN APPROVAL PRIOR TO SUBSTITUTION BEING MADE. 2.18 GC SHALL REMOVE EXISTING FLOOR COVERING WHENEVER DESIGNATED FOR REMOVAL. 2.19 DEMISING PARTITIONS SHALL BE SPECIFIED WITH SOUND ATTENUATION BATTING AND SOUND CONTROL MEMBRANE. SEE DETAILS. 2.20 SOUND ATTENUATION BATTING SHALL BE SPECIFIED AT ALL EQUIPMENT/TELEPHONE ROOMS, CONFERENCE ROOMS, AND OFFICES. 2.21 SOUND ATTENUATION BATTING SHALL BE SPECIFIED AT ALL PARTITIONS AND CEILING FOR NEW TOILETS INSIDE THE CLIENT'S SPACE. RCP & MECHANICAL SYSTEM NOTES CONSTRUCTION PLAN NOTES 2.1 PRIOR TO START OF CONSTRUCTION, GC SHALL COORDINATE SCHEDULING OF MEETING WITH HIS PROJECT PERSONNEL, THE BUILDING/LANDLORD REP(S), OWNER PROJECT MANAGER, OTHERS, FOR REVIEW OF PROJECT SCOPE, DESIGN INTENT, CONSTRUCTION QUALITY EXPECTED, & FINAL DISCUSSION OFDRAWING/DETAILS/QUESTIONS. 2.2 DIMENSIONS ON DRAWINGS ARE FINISH FACE TO FINISH FACE OF PARTITIONS, COLUMNS, ETC., OR TO WHERE SHOWN, UNLESS OTHERWISE NOTED. DO NOT SCALE DRAWINGS WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC REPRESENTATION. DETAIL DIMENSIONS TAKE PRECEDENCE OVER PLAN DIMENSIONS. 2.3 GC SHALL BE RESPONSIBLE FOR FIELD MEASURING OF EXISTING CONDITIONS PRIOR TO START OF WORK & DURING CONSTRUCTION, AS NECESSARY, TO ASSURE CONSTRUCTION ADHERENCE TO DRAWINGS. BY ENTERING INTO A CONSTRUCTION CONTRACT FOR THIS WORK, GC SHALL INDICATE HIS FAMILIARITY WITH THE SITE/FIELD, CONDITIONS. A. ALL "HOLD" DIMENSIONS SHALL BE MONITORED TO ASSURE CORRECTNESS. B. ANY DIMENSION REVISIONS/MODIFICATIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PROJECT MANAGER FOR REVIEW/APPROVAL. 2.4 ALL VERTICAL DIMENSIONS SHALL BE TAKEN FROM "BENCH MARK" OR OTHER SIMILAR GUIDE ESTABLISHED PRIOR TO START OF CONSTRUCTION. HIGH POINTS, LOW POINTS, IRREGULARITIES IN FLOOR SLAB, PARTICULARLY, WHICH COULD IN ANY WAY AFFECT FABRICATION/INSTALLATION WORK OF OTHER TRADES OR VENDORS (E.G., CABINET CONTRACTORS), SHALL BE BROUGHT TO ATTENTION OF ARCHITECT AND PROJECT MANAGER OF THE CLIENT. A. BUILDING OWNERSHIP TO REVIEW REQUIREMENT FOR LEVEL FLOOR WITH LEASE AGREEMENT. 2.5 GC SHALL DEMOLISH EXISTING PARTITION AND VARIOUS OTHER ELEMENTS AS INDICATED ON PLAN AND COORDINATE THE REMOVAL OF ALL RELATED ELECTRICAL SERVICE, PLUMBING AND ALL OTHER APPURTENANCES INCLUDED THEREIN. 2.6 GC SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL CONSTRUCTION DEBRIS AND FOR THE RETURN OF ANY BUILDING STANDARD COMPONENTS IF REQUESTED TO THE BUILDING MANAGEMENT. 2.7 ALL EXISTING DOORS DESIGNATED FOR REMOVAL, INCLUDING FRAMES, SHALL BE REUSED WHERE SAME TYPE DOOR IS APPLICABLE AND/OR IS CALLED FOR IN NEW DESIGN WHENEVER POSSIBLE. ALL EXISTING HARDWARE SHALL BE RETAINED FOR REUSE: COORDINATE WITH OWNER/ PROJECT MANAGER. 2.8 ALL CONVENTIONAL DRYWALL CONSTRUCTION, FURRING, SHEATHING, THIS CONTRACT, SHALL BE AS DETAILED (REFER TO LEGEND ENTRIES, ON CONSTRUCTION PLAN). DRYWALL JOINTS SHALL BE TAPED/SPACKLED LEVEL. EXTERIOR CORNERS SHALL RECEIVE METAL CORNER REINFORCING BEAD AND BE SPACKLED IN CONVENTIONAL MANNER. NO HORIZONTAL DRYWALL JOINTS SHALL BE ACCEPTED UNLESS APPROVED. BUTTED & UNTAPPED DRYWALL JOINTS ARE NOT ACCEPTABLE. FULL HEIGHT GYPSUM BOARD SHEETS SHALL BE USED THROUGHOUT FOR FULL HEIGHT CONSTRUCTION. A. ALL NEW DRYWALL CONSTRUCTION SHALL BE PROPERLY PREPARED TO RECEIVE SPECIFIED FINISH MATERIAL'S) IN MANNER FULLY ACCEPTABLE TO THE CLIENT. & THE ARCHITECT. B. TAPED JOINTS, CORNERS, "DIMPLES" OR SCREW HEADS SHALL BE SPECKLED SMOOTH 8c LEVEL WITH ADJACENT GYPSUM BOARD. BULGING OR UNEVEN FINISHED DRYWALL WILL NOT BE ACCEPTED. 2.9 ALL EXISTING HOLES/CRACKS IN SLAB & THOSE RESULTING FROM THE CONSTRUCTION PROCESS SHALL BE FILLED/REPAIRED 84 THE SURFACE PATCHED SMOOTH 8c LEVEL WITH ADJACENT FLOOR SURFACE. 2.10 ALL NECESSARY WOOD BLOCKING/GROUNDS, ETC, ARE TO BE SUPPLIED AS FACTORY TREATED FIREPROOFED ELEMENTS. GC SHALL COORDINATE SEI I ING/PLACEMENT OF THESE ELEMENTS AS REQUIRED BY LOCAL CODE/BUILDING OR SURROUNDING CONSTRUCTION CONDITIONS. A. GROUNDS/BLOCKING MAY NOT BE WHOLLY SHOWN ON DRAWINGS & GOOD CONSTRUCTION PRACTICE SHALL GOVERN/DETERMINE SAID USE WHERE A QUESTION ARISES. B. GC TO PAY PARTICULAR ATTENTION TO ALL LOCATIONS OF DRYWALL PARTITION CONSTRUCTION THAT ABUT OR ARE TO RECEIVE MILLWORK OR CABINETWORK CONSTRUCTION. INTERNAL WOOD BLOCKING SHALL BE SUPPLIED FOR STURDY ANCHORAGE AT INTERSECTIONS OF WOOD/GLASS BORROWED LIGHT PARTITIONS AND ADJACENT DRYWALL CONSTRUCTION, UNIVERSALLY. C. BLOCKING FOR ALL MILLWORK INSTALLATIONS, BUILT-IN FURNITURE, DRAPERY TRACKS, PRESENTATION BOARDS, ETC. SHALL BE PROVIDED BY GC. REFER TO FURNITURE PLAN AND FINISH PLAN FOR COMPLETE SCOPE. REFER TO MECHANICAL PLAN FOR BLOCK REQUIREMENTS FOR WALL MOUNTED HVAC EQUIPMENT IN TELEPHONE EQUIPMENT ROOM. 2.11 GC SHALL PROVIDE GENERAL CARPENTRY AS REQUIRED FOR WORK WHICH MAY NOT FALL INTO JURISDICTION OF A SPECIFIC TRADE, BUT IS REQUIRED FOR PROPER JOB EXECUTION Sc COMPLETION OF CONSTRUCTION. 2.12 INSTALL ALL PLUMBING NECESSARY FOR THE INDICATED PLUMBING FIXTURES/APPURTENANCES. SAID UNITS SHALL BE AS SPECIFIED. (REFER TO MECHANICAL PLANS). 2.13 ANY ACCESS PANELS REQUIRED IN CONSTRUCTION THIS ANY CONTRACT SHALL BE APPROVED AS TO SPECIFIC SIZE, LOCATION, FINISH, ETC., BY ARCHITECT. 2.14 GC, SUBCONTRACTORS, AND ALL VENDORS ARE TO VERIFY ALL CLEARANCES (CORRIDORS, STAIRS, ELEVATORS, ETC.) REQUIRED FOR DELIVERIES, PASSAGE OF ALL JOB MATERIALS/ EQUIPMENT. A. GC SHALL SCHEDULE FOR & INCLUDE COSTS/FEES NECESSARY FOR USE OF BUILDING ELEVATOR OR ANY SPECIAL CARTAGE, RIGGING, HOISTING, DELIVERIES, TRANSPORTATION, ETC. CONNECTED WITH CONTRACT WORK. B. GC SHALL COORDINATE CLOSELY WITH VARIOUS THE CLIENT VENDORS OR CONTRACTORS, REGARDING INFORMATION IN PART "A", THIS NOTE, ABOVE. 2.15 EXISTING GYPSUM BOARD SHEATHING, ANY AREA THIS PROJECT (TO INCLUDE CORE & PERIMETER COLUMNS & WALLS) SHALL BE PATCHED, SPACKLED, AS REQUIRED, IF DAMAGED IN ANY MANNER, DURING CONSTRUCTION, TO SATISFACTION OF THE CLIENT, THE BUILDING MANAGER & THE ARCHITECT. 3.1 SCOPE: GC SHALL FURNISH & INSTALL CONTINUOUS GRID SUSPENDED ACOUSTICAL TILE CEILING MATERIAL AS SPECIFIED & AS INDICATED ON PLAN & PROVIDE CUT OUTS 8c OTHER PROVISIONS FOR OTHER TRADES AS REQUIRED. 3.2 SPECIFICATION: HUNG CEILING SHALL BE IN CONFORMANCE WITH ASTM C635 & WITH GENERAL PRACTICES & APPLICABLE STATE & LOCAL ORDINANCES. INSTALLATION IN CONFORMANCE WITH MANUFACTURER RECOMMENDATIONS & ASTM C636. 3.3 GC SHALL VERIFY CONFORMANCE WITH LOCAL & STATE CODES & BUILDING STANDARDS BEFORE SUBMITTING BIDS. 3.4 CEILING PLANE SHALL BE LEVEL 8c TRUE, & IN ALIGNMENT WITH ALL UGHTING, SPRINKLER, HVAC, & OTHER ELEMENTS INCORPORATED IN ITS CONSTRUCTION. GRID SHALL BE CONTINUOUS THROUGHOUT THE DEMISED AREA. 3.5 ACOUSTICAL CONTRACTOR SHALL COORDINATE WORK WITH CARPENTRY TRADES TO PROVIDE FOR A NEAT, LEVEL VISUAL LINE AT THE INTERSECTION OF CEILING & PARTITIONS. 3.6 FASCIAS/SOFFITS SHALL BE LEVEL & TRUE, FREE OF SURFACE DISTORTION 8c DIMENSIONED ACCORDING TO DETAILS SHOWN. 3.7 MECHANICAL, HVAC & PLUMBING ELEMENTS SHALL AT NO TIME COME IN CONTACT WITH CEILING CONSTRUCTION EXCEPT AS NECESSARY PENETRATIONS MAY REQUIRE. 18 ACCESS SHALL BE PROVIDED BY GC AS REQUIRED FOR INSTALLATION 8c MAINTENANCE OF MECHANICAL, ELECTRICAL & OTHER ELEMENTS WITHIN CEILING PLENUM & AS REQUIRED BY CODE. LOCATIONS FOR SPECIAL ACCESS DOORS, HATCHES, ETC. SHALL BE COORDINATED WITH OTHER TRADES & APPROVED BY THE ARCHITECT. AS -BUILT REFERENCE PLANS SHALL BE PROVIDED. 3.9 INSPECTIONS, AS REQUIRED BY LOCAL AUTHORITIES SHALL BE COORDINATED BY GC PRIOR TO CLOSING OF CEILING. 3.10 SHOP DWGS. FOR ALL RELATED TRADES (PLUMBING, SPRINKLER, HVAC) SHALL BE SUBMITTED TO THE CLIENT FOR REVIEW/APPROVAL PRIOR TO MANUFACTURING & INSTALLATION. A COORDINATED SHOP DRAWING FOR ALL VISIBLE CEILING ELEMENTS SHALL BE SUBMITTED. 3.11 HVAC SUPPLY, RETURN, EXHAUST GRILLS SHALL BE AS SPECIFIED IN MECHANICAL DRAWINGS OR "BUILDING STANDARD" IF NOT SPECIFIED. GC TO VERIFY CONFORMANCE OF SPEC WITH BUILDING STANDARDS. ALL HVAC ELEMENTS SHALL BE OFF-WHITE (TO MATCH CEILING) INSTALLED FLUSH & TRUE St CENTERED WITHIN THE CEILING GRID. LOCATIONS SHALL BE PER APPROVED MECHANICAL PLANS. 3.12 ENGINEERING SERVICES FOR DESIGN OF MECHANICAL SYSTEMS SHALL BE PROVIDED BY GC OR OWNER IF NO ENGINEERING DOCUMENTS ARE ISSUED AS PART OF THIS SET. PROVIDER OF ENGINEERING SERVICES SHALL SUBMIT COMPLETE CONSTRUCTION DOCUMENTS TO THE ARCHITECT FOR REVIEW/APPROVAL PRIOR TO START OF WORK. 3.13 MECHANICAL & ELECTRICAL ENGINEER SHALL COORDINATE WORK WITH ARCHITECTURAL DRAWINGS. ARCHITECTURAL CEILING PLAN SHALL GOVERN WITH RESPECT TO LOCATIONS FOR CEILING PENETRATIONS AS AESTHETIC & FUNCTIONAL CONSIDERATIONS DICTATE. MECHANICAL DOCUMENTS SHALL TAKE PRECEDENCE WITH RESPECT TO OVERALL SCOPE OF WORK. 3.14 DUCTWORK, WHEN CONTINUOUS THROUGH MORE THAN ONE ROOM, SHALL BE ACOUSTICALLY LINED TO DIMINISH SOUND TRANSMISSION THROUGH DUCTS., UNLESS OTHERWISE NOTED. 3.15 CLEARANCES FOR ALL RELATED CEILING PLENUM INSTALLATIONS, SHALL BE COORDINATED BY GC AT NO ADDITIONAL COST. 3.16 SUPPLEMENTAL COOLING UNIT(S) SHALL PROVIDE TEMPERATURE & HUMIDITY CONTROL ON A 24 HOUR BASIS IN TELEPHONE/ COMMUNICATIONS EQUIPMENT ROOM. A. HEAT LOAD & ENVIRONMENTAL REQUIREMENTS OF COMMUNICATIONS EQUIPMENT SHALL DETERMINE CAPACIIY OF COOLING UNIT(S). REFER TO EQUIPMENT SCHEDULE 8c EQUIPMENT SPECS. B. CAPACITY OF SUPPLEMENTAL UNIT SHALL BE AT LEAST 50 % GREATER THAN SPECIFIED LOAD TO ALLOW FOR FUTURE GROWTH., UNLESS OTHERWISE NOTED. C. INSTALLATION SHALL INCLUDE ALL SAFETY 8c EMERGENCY FUNCTIONS, ALL ELECTRICAL CONNECTIONS & CONTROLS; ALL PLUMBING & OVERFLOW PANS, ETC. D. SPECIFIER OF UNIT(S) SHALL VERIFY COMPLIANCE WITH LOCAL CODES & BUILDING STANDARDS & REQUIREMENTS. E. SPECIFIER SHALL PRESENT ALTERNATE PROPOSALS FOR SUPPLEMENTAL COOLING SYSTEM FOR REVIEW/APPROVAL BY THE CLIENT, INCLUDING OPERATING COST DATA VERSUS SYSTEM SPECIFIED. F. CONTROL DEVICES SHALL BE SPECIFIED TO ALTERNATING ASSURE OPERATION OF BACK-UP SUPPLEMENTAL COOLING UNITS. 3.17 INSULATION OF COLD WATER LINES & DUCTS SHALL BE PROVIDED TO PREVENT CONDENSATION DAMAGE & IN OBSERVANCE OF ENERGY CONSERVATION PRACTICES. 3.18 ATTACHMENTS OF VARIOUS HVAC ELEMENTS TO STRUCTURE SHALL BE APPROVED IN WRITING BY STRUCTURAL CONSULTANT LANDLORD REPRESENTATIVE. OR AUTHORIZED. 3.19 DOMESTIC HOT WATER SHALL BE PROVIDED AT ALL SINKS & LAVATORIES. IF BUILDING SYSTEMS DO NOT PROVIDE HOT WATER, GC TO PROVIDE WATER HEATER. 3.20 WATER HEATER SHALL BE SPECIFIED ON RELATED MECHANICAL PLANS. IF NO PLANS ARE ISSUED, GC SHALL SUBMIT SPEC FOR APPROVAL ALONG WITH BID OR AS REQUIRED WITH MECHANICAL PLANS. A. HEATER SHALL BE ABOVE CEILING, STORAGE TANK TYPE INCLUDING ALL NECESSARY PIPING, ACCESSORIES & SAFETY FEATURES, UNLESS OTHERWISE NOTED. B. ALL HOT WATER PIPES SHALL BE INSULATED. 3.21 FIRE PROTECTION SYSTEMS AS SPECIFIED OR REQUIRED BY CODE, SHALL BE PROVIDED BY GC. MINIMUM SPRINKLER INSTALLATION MUST MEET REQUIREMENTS OF NFPA 13. 3.22 SPRINKLER HEAD LOCATION SHALL BE .GOODWITH OTHER TRADES BY GC & SHALL BE AS SPECIFIED BY ENGINEER OR AS REQUIRED BY CO SpR1T9RL S"W LLEENTERED WITHIN EACH CEILING TILE TO PROVIDE A UNIFIED, CONSISTENT G BE WHITE FLUSH TYPE OR BUILDING ST8cARD IF EQUAL OR BETTER. 3.23 ARCHITE SCOPE. °CATION, ENGINEERING PLANS SHALL PREVAIL IN QUESTIONS OF CIRCUITING & 3.24 EMERGENCY LIGHTING & UNCIATOR/ALARM SYSTEMS SHALL BE SPECIFIED BY ENGINEER. IF ENGINEERING DOCUMENTS ARE NOT ISSUED, GC SHALL PROVIDE THESE SYSTEMS AS REQUIRED BY CODE & COORDINATE LOCATIONS WITH OWNER/THE ARCHITECT. 3.25 MULTIPLE SWITCHES SHALL BE GANGED WITH SINGLE COMMON COVER PLATE. 3.26 NEW SWITCHES SHALL MATCH EXISTING TYPE USED WHERE EXISTING SWITCHES ARE TO REMAIN. 3.27 ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE 2005 "NATIONAL ELECTRICAL CODE" & ANY & ALL APPLICABLE STATE & LOCAL CODES/ORDINANCES. 5.1 FURNISHINGS ARE SPECIFIED BY ARCHITECT OR TENANT CONTRACTED VENDOR. 5.2 SCOPE: ALL FURNITURE SHOWN IS TO BE PROVIDED BY VENDORS OTHER THAN GC. SCOPE OF WORK BY GC RELATED TO COORDINATION OF INSTALLATION WITH VENDORS IS NOTED. 5.3 ALL FURNITURE AND EQUIPMENT IS NEW EXCEPT AS NOTED. 5.4 FURNITURE SUPPLIER IS TO PROVIDE AND INSTALL ALL FURNISHINGS SPECIFIED AS SHOWN WITH NO SUBSTITUTIONS. PRICES ARE TO INCLUDE SHIPPING AND FREIGHT CHARGES AND FEES, LICENSE, PERMITS AND INSTALLATION BY QUALIFIED LABOR DURING NORMAL BUSINESS HOURS. OVERTIME DELIVERIES, IF REQUIRED BY BUILDING MANAGEMENT ARE TO BE COORDINATED WITH AND APPROVED BY OWNER. 5.5 VENDOR SHALL ALLOW FOR ACCESS/ PATH OF TRAVEL AND ANY BUILDING ELEVATOR USE FEES, LOADING DOCK FEES, ETC., AND SHALL COORDINATE DELIVERY SCHEDULES WITH BUILDING MANAGEMENT AND OWNER, PROTECTION AS REQUIRED. 5.6 VENDOR TO VERIFY CAPACITIES, DIMENSIONS OF FREIGHT ELEVATORS AND DELIVERY PATH TO ASSURE ADEQUATE PASSAGE. 5.7 COMPLIANCE WITH LOCAL CODES AND ORDINANCES SHALL BE THE RESPONSIBILITY OF FURNITURE VENDOR (INCLUDING PAYMENT OF ANY FINES FOR NONCOMPLIANCE). 5.8 BUILDING LANDLORD REQUIREMENTS WITH RESPECT TO LABOR AGREEMENTS AND PROOF OF INSURANCE WILL BE MET BY VENDOR. 5.9 PROTECTION SHALL BE PROVIDED BY VENDOR FOR ALL SURFACES SUSCEPTIBLE TO DAMAGE DURING DELIVERY. VENDOR SHALL BE RESPONSIBLE TO CORRECT ANY DAMAGES CAUSED BY DELIVERY AND COORDINATION WITH BUILDING MANAGEMENT. 5.10 BUILT-IN FILES AND CABINETS REQUIRE COORDINATION WITH GC -AND WORK BY OTHER TRADES SPECIFIED IN OTHER SECTIONS. FURNITURE VENDOR SHALL ASSEMBLE, PLACE AND LEVEL CABINETS WITHIN ENCLOSURES PROVIDED. (PLATFORMS, REVEAL STRIPS WORK TOPS, ETC., BY MILLWORK CONTRACTOR) GENERAL: 5.11 FREESTANDING FILE BANKS SHALL BE LEVELED AND BOLTED TOGETHER BY VENDOR. 5.12 LOCKS ARE SPECIFIED FOR ALL FILE CABINETS. CABINETS WITHIN ONE BANK SHALL BE KEYED ALIKE BUT EACH BANK KEYED DIFFERENTLY. 5.13 LOCKS WHEN SPECIFIED FOR OFFICE SUITES AND COMPONENT ASSEMBLIES SHALL BE KEYED ALIKE WITHIN EACH WORK STATION. 5.14 TWO KEYS SHALL BE PROVIDED FOR EACH LOCK. 5.15 IDENTIFICATION NUMBERS/TAGS SHALL BE PROVIDED FOR ALL LOCKS AND KEYS. FINISH PLAN NOTES 6.1 ALL FINISHED MATERIALS INDICATED TO BE BY GC UNLESS OTHERWISE NOTED IN FINISH SCHEDULE(S), ON FINISH PLAN. 6.2 GC AND VENDORS SHALL DETERMINE AVAILABILITY OF ALL FINISH MATERIALS. ANY DELIVERY SCHEDULE THAT POTENTIALLY MAY CAUSE COORDINATION PROBLEMS DURING THE FINAL STAGES OF CONSTRUCTION/INSTALLATION SHALL BE BROUGHT TO ATTENTION OF ARCHITECT, EARLY ON, FOR POSSIBLE RE-EVALUATION OF MATERIAL DESIGNATION. 6.3 A MINIMUM QUANTITY OF TWO (2) 1'-0" X 1'-0" FINISH SAMPLES OF ALL SPECIFIED FINISHES AND CURRENT STOCK CUTTINGS OF ALL SPECIFIED WALL COVERINGS SHALL BE PROVIDED FOR APPROVAL PRIOR TO ORDERING. 6.4 PAINT FOR WALL FINISHES SHALL BE PROVIDED AS A THREE (3) COATS (FINISH TBD) LATEX ENAMEL PAINT INSTALLATION ONE (1) PRIME AND TWO (2) FINISH COAT, COLORS AS SPECIFIED. METAL ELEMENTS AND DOOR AND WINDOW FRAMES SHALL HAVE A THREE -COAT ALKYD FINISH TBD. 6.5 GC SHALL ASSURE THAT NO ELECTRIC RECEPTACLE OR TELECOMMUNICATIONS OUTLET COVERPLATES HAVE BEEN INSTALLED PRIOR TO COMPLETION OF APPLICATION OF ANY WALL FINISH MATERIALS. ANY SUCH COVERPLATES OR SURFACE HARDWARE. ETC., IN PLACE. SHALL BE REMOVED PRIOR TO WALL FINISH APPLICATION. 6.6 UPON COMPLETION OF FINISH PHASE OF JOB, GC SHALL REMOVE ALL PAINT, WALL COVERING PASTE, ETC., FROM WHERE IT HAS SPILLED, SPLASHED, OR SPATTERED. 6.7 GC SHALL INSTALL ALL WALL COVERINGS WHERE DESIGNATED. ALL WALL COVERING SHALL BE SMOOTH WITH NO WRINKLES, BUBBLES, BLISTERS, OR LOOSE EDGES. ALL EXCESS PASTE SHALL BE THOROUGHLY REMOVED. WALL COVERING ADJOINING WOOD OR METAL PARTITIONS SHALL BE CUT STRAIGHT AND SQUARE. WALL COVERING AT ALL REVEALS SHALL RETURN INTO REVEAL. ALL WORKMANSHIP WHICH IS NOT JUDGED TO BE FIRST QUALITY BY THE CLIENT WILL NOT BE ACCEPTED. NO WALL COVERING SHALL TERMINATE ON A FLAT SURFACE OR ON AN OUTSIDE COMER. ALL WALL COVERING SHALL TERMINATE AT AN APPROPRIATE REVEAL/BREAK OR INSIDE COMER. 6.8 ALL WALL SURFACES RECEIVING WALL COVERING SHALL BE PRIMED WITH A SUITABLE STIPPABLE PRIMING MATERIAL. NO "ONE STEP" PRIMER/ADHESIVE SHALL BE USED. SAID PRIMER SHALL BE COMPATIBLE WITH THE RECOMMENDED ADHESIVE FOR RESPECTIVE WALL COVERING BEING USED. 6.9 ALL PARTITIONS SHALL RECEIVE RUBBER BASE INSTALLATION EXCEPT WHERE OTHERWISE NOTED, ALL SURFACES RECEIVING BASE SHALL BE PREPARED AS REQUIRED. A. AREAS INDICATED AS RECEIVING CARPET FLOOR FINISH SHALL HAVE STRAIGHT BASE APPLIED, PRIOR TO CARPET INSTALLATION B. AREAS INDICATED AS RECEIVING VINYL COMPOSITION TILE FLOOR FINISH SHALL HAVE COVED VINYL BASE APPLIED AFTER VINYL COMPOSITION TILE INSTALLATION. 6.10 VINYL COMPOSITION TILE INSTALLATION SHALL BE UNI-DIRECTIONAL. SEAMS SHALL BE TIGHT/INVISIBLE. GC SHALL PROVIDE AND MAINTAIN ADEQUATE PROTECTION FOR ALL NEW INSTALLED VINYL COMPOSITION TILE FOR THE DURATION OF CONSTRUCTION AND REMOVE PROTECTION ONLY IMMEDIATELY BEFORE JOB COMPLETION, FLOOR WILL BE THOROUGHLY CLEANED OF ALL ADHESIVE/CONSTRUCTION STAINS AND RECEIVE AN APPROPRIATE TWO (2) COAT NON -SLIP WAX APPLICATION WHICH IS TO BE THOROUGHLY MACHINE BUFFED TO SATISFACTION OF THE CLIENT. (CLEAN/WAX BY GC.) 6.11 GC SHALL PROVIDE AND MAINTAIN COMPLETE PROTECTION FOR ALL NEW INSTALLED FLOOR FINISHES (INCLUDING CARPET) UNTIL ALL CONSTRUCTION WORK IS COMPLETE. PROTECTION SHALL BE REMOVED ONLY IMMEDIATELY PRIOR TO JOB COMPLETION. 6.12 CARPET SUPPLIER/INSTALLER SHALL PROVIDE CURRENT STOCK SAMPLES OF SPECIFIED CARPET FINISHES FOR APPROVAL PRIOR TO ORDERING. PROVIDE VINYL TRANSITION STRIPS AS SPECIFIED OR NECESSARY (IF NOT SPECIFIED). 6.13 GC, ALL VENDORS/SUBCONTRACTORS ARE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, QUANTITIES ETC., OF THEIR RESPECTIVE WORK. 6.14 AREAS OF CARPET TO STONE TRANSITION ARE TO BE FLASHED/FEATHERED MINIMUM 18" TO TRIPPING/ WEAR ISSUE. 1. GENERAL: ALL WORK TO BE DONE IN ACCORDANCE WITH THE LOCAL AND STATE BUILDING CODE, AND REGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. 2. STRUCTURAL: A. CONTRACTOR TO PROVIDE ADEQUATE TEMPORARY BRACING AND SHORING WHEREVER ANY STRUCTURAL WORK IS INVOLVED. B. ALL DEMOLITION OPERATIONS, REPAIR OPERATIONS, AND ALTERATION OPERATIONS TO BE DONE IN ACCORDANCE WITH THE LOCAL AND STATE BUILDING CODE. MEANS OF EGRESS: ALL EXISTING MEANS OF EGRESS FOR TENANTS OF THE BUILDING, TO BE MAINTAINED CLEAR AND FREE OF ALL OBSTRUCTIONS, SUCH AS BUILDING MATERIALS, TOOLS, ETC. 4. FIRE SAFETY: A. ALL BUILDING MATERIALS STORED AT CONSTRUCTION AREA AND/OR ANY AREA OF THE BUILDING ARE TO BE SECURED IN A LOCKED AREA. ACCESS TO SUCH AREAS TO BE CONTROLLED AND/OR GENERAL CONTRACTOR. B. ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION. C. ALL FLAMMABLE MATERIALS TO BE KEPT TIGHTLY SEALED IN THEIR MANUFACTURER'S CONTAINERS. SUCH MATERIALS ARE TO KEPT AWAY FROM HEAT. D. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE. E. ALL ELECTRICAL POWER TO BE SHUT-OFF WHERE THERE IS EXPOSED CONDUIT. F. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT-OFF AFTER WORKING HOURS. G. CONTRACTOR IS AT ALL TIMES TO ENSURE THERE IS NO LEAKAGE OF NATURAL GAS IN THE BUILDING, OR ANY FLAMMABLE GAS USED IN CONSTRUCTION. 5. DUST CONTROL: A. DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM, AND BE CONFINED TO THE IMMEDIATE CONSTRUCTION AREA. B. CONTRACTOR TO ISOLATE CONSTRUCTION AREA FROM OCCUPIED BUILDING AREAS BY MEANS OF TEMPORARY PARTITIONS OR HEAVY WEIGHT DROP CLOTHS. C. DEBRIS, DIRT AND DUST TO BE CLEANED UP AND CLEARED FROM BUILDING PERIODICALLY TO AVOID ANY EXCESSIVE ACCUMULATION. 6. NOISE AFTER HOURS: A. CONSTRUCTION OPERATIONS WILL BE CONFINED TO NORMAL WORKING HOURS: 8 AM TO 5 PM, MONDAYS THROUGH FRIDAYS, EXCEPT LEGAL HOLIDAYS. B. CONTRACTOR TO OBTAIN THE WRITTEN CONSENT OF ALL PARTIES AFFECTED BY HIS WORKING DURING OTHER THAN REGULAR HOURS. C. CONSTRUCTION OPERATION WILL NOT INVOLVE INTERRUPTION OF HEATING, WATER, OR ELECTRICAL SERVICES TO OTHER TENANTS OF THE BUILDING. LIGHTING NOTES MILLWORK & CABINETRY NOTES ELECTRICAL PLAN NOTES 4.1 SCOPE: GC SHALL PROVIDE ALL ELECTRICAL WORK AS SHOWN OR IMPLIED IN THESE DRAWINGS AND RELATED ENGINEERING DRAWINGS (IF ANY) INCLUDING ALL CONDUIT RUNS FOR POWER AND SIGNAL; DRAG LINES; PULL BOXES; WIRING; RECEPTACLES AND SWITCHING DEVICES; CORE DRILLING AND PATCHING; ETC.; AS SPECIFIED OR IMPLIED OR AS REQUIRED BY CODE OR BUILDING STANDARDS. 4.2 EQUIPMENT: TELEPHONE AND DATA EQUIPMENT, TERMINALS, ETC., EXCEPT AS SPECIFICALLY CALLED FOR, SHALL BE PROVIDED BY OTHERS. GC SHALL PROVIDE FOR COORDINATION WITH VENDORS/ INSTALLERS REGARDING DELIVERIES, SCHEDULES, AS DIRECTED. 4.3 LOCATIONS AND DIMENSIONS SHALL BE PER ARCHITECTURAL DRAWINGS; ENGINEERING DOCUMENTS (IF ANY) SHALL PREVAIL IN CASE OF VARIATION IN SPECIFICATIONS. DISCREPANCIES MUST BE BROUGHT TO THE ATTEN110N OF OWNER /THE ARCHITECT BEFORE START OF WORK. FURNITURE INDICATED ON PLANS IS FOR REFERENCE ONLY. 4.4 VARIATIONS FROM WORK SPECIFIED DUE TO AVAILABILITY OF MATERIALS; FIELD CONDITIONS, VARIATIONS IN EQUIPMENT SPECS, ETC., MAY BE MADE WITH THE APPROVAL OF THE CLIENT & THE ARCHITECT. 4.5 FIELD VERIFICATIONS: GC AND SUBCONTRACTORS SHALL BE RESPONSIBLE TO VERIFY FIELD CONDITIONS AND DIMENSIONS BEFORE BEGINNING WORK. SIZES OF CONDUITS AND PULL BOXES SHALL BE ADEQUATE FOR CABLES/SERVICE SPECIFIED. A. GC SHALL BE PROVIDED 1" DIA CONDUIT FOR ALL DATA/TELEPHONE OUTLETS. U.O.N. 4.6 ADJACENT TENANTS: GC SHALL INCLUDE REPAIRS TO ADJACENT TENANT SPACES WHEN WORK AFFECTS THOSE AREASWORK IN ADJACENT TENANT SPACES SHALL NOT BE SCHEDULED DURING NORMAL WORKING HOURS. 4.7 COMPLIANCE: ALL WORK SHALL BE PERFORMED IN COMPLETE COMPUANCE WITH THE NATIONS ELECTRICAL CODE AND/ALL FEDERAL STATE OR LOCAL CODES AND ORDINANCES HAVING JURISDICTION. 4.8 COMPATIBILITY: ALL DEVICES, WIRING, ETC., SHALL BE COMPATIBLE, EACH WITH ONE ANOTHER AND WITH EXISTING WORK AND BUILDING STANDARDS. 4.9 CIRCUITING SHALL BE AS SHOWN ON ENGINEERING DOCUMENTS (IF ISSUED) OR IN ACCORDANCE WITH APPLICABLE CODES AND STANDARD PRACTICE. GC SHALL PRESENT CIRCUITING DIAGRAM TO OWNER FOR APPROVAL IF ENGINEERING DOCUMENTS ARE NOT ISSUED. 4.10 ENGINEERING: PROVIDER OF ELECTRICAL ENGINEERING SERVICES SHALL SUBMIT FINAL DRAWINGS TO OWNER FOR APPROVAL (ONE (1) CLEAR REVERSE SEPIA AND ONE (1) BLACK LINE PRINT). IF NO ENGINEERING DOCUMENTS ARE ISSUED AS PART OF THIS CONTRACT, GC SHALL INCLUDE FEES FOR THIS SERVICE IN HIS BID. 4 1 WALL OUTLETS: ELECTRICAL SUBCONTRACTOR SHALL PROVIDE APPROPRIATE METAL SERVICE BOXES AND JUNCTION BOXES FOR ALL POWER AND SIGNAL OUTLETS ALONG WITH APPROPRIATE COVER PLATE AND DEVICES AS SPECIFIED. HEIGHTS SHALL BE AS CALLED FOR OR AS FOLLOWS: TYPICAL OFFICE RECEPTACLES 15" AFF. TYPICAL LIGHT SWITCH 38" AFT. 4.12 ALL OUTLETS SHOWN SIDE -BY -SIDE SHALL BE SPACED AT 6" O.C. UNLESS OTHERWISE NOTED. 4.13 PROTECTION: ALL ELECTRICAL DEVICES, WHEN INSTALLED, SHALL BE PROTECTED FROM DAMAGE BY OTHER TRADES. COVER PLATES FINISH MATERIALS HAVE BEEN APPLIED. SHALL BE INSTALLED AFTER SEE FINISH PLAN. 4.14 FLOOR OUTLETS SHALL BE FLUSH TYPE UNLESS PROHIBITED BY BUILDING MANAGEMENT. GC SHALL FURNISH CUT/SAMPLE FOR APPROVAL UNDER CARPET WIRING MAY NOT BE USED EXCEPT AS SPECIFIED AND AS LOCAL CODES AND BUILDING MANAGEMENT PERMITS. FLOOR OUTLET LOCATIONS TO BE REVIEWED BY BUILDING MANAGEMENT PRIOR TO CUTTING OF SLAB. 4.15 SURFACE MOUNTED WIRING DEVICES SHALL_ NOT BE USED BY GC, HIS SUBS OR ANY ELECTRICAL VENDOR OR INSTALLER, EXCEPT AS SPECIFIED TO COORDINATE WITH FURNITURE/ MILLWORK INSTALLATION. 4.16 TERMINATIONS OF SIGNAL CABLE SHALL BE MADE WITH DEVICE AS SPECIFIED OR ELSE INSTALLER SHALL PROVIDE 10.-0" MIN. SLACK TO ALLOW FOR CONNECTION TO EQUIPMENT. COVER PLATE WITH GROMMET SHALL BE PROVIDED. 4.17 COORDINATION OF ELECTRICAL WORK WITH HVAC, CABINET WORK, CARPENTRY, FURNITURE, SHALL BE ASSURED BY GC. 4.18 RACEWAYS PROVIDED BY OTHERS WITHIN CUSTOM CABINETRY AND MILLWORK OR OFFICE LANDSCAPE PARTITION SYSTEMS SHALL BE USED FOR ELECTRICAL INSTALLATIONS. 4.19 OFFICE LANDSCAPE PARTITIONS: MODULAR POWER WAYS AND RECEPTACLE DEVICES FOR ELECTRICAL SERVICE IN LANDSCAPE PARTITIONS SHALL BE PROVIDED BY FURNITURE VENDOR (EXCEPT WHERE PROHIBITED BY CODE). ELECTRICAL SUBCONTRACTOR TO PROVIDE FOR SERVICE TO POINT OF INTERFACE WITH LANDSCAPE PANELS AND TO INSTALL DEVICES IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4.20 P.A. SYSTEM: GC TO PROVIDE CONDUIT RUNS IF REQ'D. CABLING AND SPEAKER INSTALLATION BY GC, AS SPECIFIED. 4.21 AVAILABILITY OF ADEQUATE POWER SERVICE SHALL BE VERIFIED BY ELECTRICAL CONTRACTOR. COSTS FOR ADDMONAL CIRCUIT PANELS, TRANSFORMERS, ETC., IF REQ'D, SHALL BE INCLUDED IN BASE BID. 4.22 CONNECTION OF SERVICES: ELECTRICAL CONTRACTOR SHALL PROVIDE METAL CONDUIT FOR CONNECTION OF TENANT TELEPHONE ROOM WITH BUILDING TELEPHONE CLOSET AS REQUIRED. 4.23 DOS11NG SIGNAL CABLES, IF IN USE BY RESIDING TENANTS, MAY NOT BE DISTURBED OR CUT. GC SHALL BE RESPONSIBLE TO RESTORE ANY SERVICES WHICH ARE INADVERTENTLY INTERRUPTED. 4.26 REFER TO SCOPE OF MECHANICAL AND HVAC INSTALlAllONS FOR RELATED ELECTRICAL WORK TO BE INCLUDED. 7.1 SCOPE: ALL FINISHED MILLWORK, WOODWORKING, AND CABINETRY INCLUDING WOOD DOORS, JAMBS, FRAMES, WINDOW FRAMES, TRIM, COUNTERS, PANELS, MOLDINGS, CABINET REVEALS, BLOCKING AND INSTALLATION OF RELATED HARDWARE IS TO BE COMPLETED BY MILLWORK CONTRACTOR (MC) AS SUBCONTRACTOR TO GC UNLESS OTHERWISE NOTED. SEE DRAWINGS FOR SCOPE OF MILLWORK BY GC AND OTHER MILLWORK BY OTHERS. 7.2 SCHEDULING AND COORDINATION WITH OTHER TRADES WILL BE THE RESPONSIBILITY OF THE GC WHETHER MILLWORK 15 INCLUDED IN HIS WORK OR NOT. 7.3 FURNITURE AS SHOWN ON FURNITURE PLAN IS BY OTHERS. MC REFER TO FURNITURE PLAN FOR SCOPE OF WORK RELATED TO FURNITURE INSTALLATION (FILE PLATFORMS, REVEALS, ETC.) 7.4 DETAILING OF MILLWORK SHALL BE AS SHOWN. MC SHALL SUBMIT SHOP DRAWINGS FOR REVIEW TO VERIFY CONFORMANCE TO SPECS. 7.5 FIELD MEASUREMENTS SHALL BE VERIFIED BY MC AS REQUIRED. OWNER WILL NOT VERIFY FIELD CONDITIONS AND DIMENSIONS ON SHOP DRAWINGS. 7.6 COORDINATION OF MILLWORK WITH EXISTING AND NEW CONSTRUCTION AND WITH MECHANICAL, FURNITURE AND OTHER RELATED ELEMENTS SHALL BE THE RESPONSIBILITY OF THE GC. 7.7 MATERIALS SHALL BE AS SPECIFIED AND OF HIGHEST QUALITY BY ACCEPTED COMMERCIAL STANDARDS. 7.8 SUITABLE MOISTURE RESISTANT/WATERPROOF SUBSTRATE SHALL BE USED FOR PLASTIC LAMINATE PIECES TO PREVENT FAILURE DUE TO MOISTURE. 7.9 SUBSTRATE FOR VENEERED AND LAMINATED PANELS SHALL BE FURNITURE GRADE PLYWOOD FOR ALL HORIZONTAL SURFACES AND SHELVES. (HIGH DENSITY PARTICLE BOARD MAY BE USED FOR VERTICAL ELEMENTS.) 7.10 EDGES OF VENEERED PANELS SHALL MATCH SURFACE. EDGES LESS THAN 1" SHALL BE HARDWOOD. 7.11 WOOD VENEERS SHALL BE SINGLE SHEET 1/20" THICK WITH NO SPLICES (EXCEPT AS CALLED FOR). JOINTS AND GRAIN DIRECTION SHALL BE INDICATED ON SHOP DRAWINGS. ADJACENT JOINTED VENEERS SHALL BE BOOK MATCHED UNLESS OTHERWISE NOTED. 7.12 ALL VENEERS SHALL BE STAINED TO MATCH STANDARD SAMPLE. 7.13 NOT USED 7.14 FINISH SAMPLES SHALL BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION. 7.15 PLASTIC LAMINATE SHALL BE SHOP APPLIED ACCORDING TO MANUFACTURERS SPECIFICATIONS. 7.16 PLASTIC LAMINATE SHALL BE ONE SINGLE SHEET ON ANY ONE SURFACE. JOINTS, IF REQUIRED, SHALL BE INDICATED ON SHOP DRAWINGS FOR APPROVAL. ALL JOINTS SHALL BE TIGHT WITH NO SEPARATION. 7.17 WOOD DOOR AND WINDOW FRAMES, ETC., SHALL BE SECURED TO SOLID WOOD GROUNDS/ BLOCKING PROVIDED AS PART OF CEILING AND WALL CONSTRUCTION. 7.18 DIMENSIONS FOR WOOD FRAMES SHALL BE VERIFIED BY FIELD MC AFTER RELATED ADJACENT CONSTRUCTION IS COMPLETE. 7.19 WOOD REVEAL FILLERSTRIPS SHALL BE PROVIDED BY MC FOR ALL BUILT-IN CABINETS. FILLERS SHALL BE OF CLOSE GRAINED STOCK, FILLED, SANDED AND PAINTED (SEMI -GLOSS) TO MATCH ADJACENT CONSTRUCTION (EXCEPT AS NOTED). FILLERS SHALL BE INCLUDED FOR ALL BUILT-IN FILES, STORAGE CABINETS, BOOKCASES, ETC. 7.20 INSTALLATION OF REVEAL STRIPS SHALL BE EXECUTED IN A NEAT, WORKMANLIKE MANNER WITHOUT DAMAGE TO ADJACENT CABINETS OR SURFACES. PIECES SHALL BE SCRIBED TO FIT AND FASTENED TO BLOCKING. 7.21 GLAZING FOR WOOD/GLASS PARTITIONS SHALL BE 3/8" THICK TEMPERED 8c TINTED, INSTALLED AS SHOWN USING FRICTION -FIT BLACK GASKET AND OPEN JOINTS. GLASS PANELS SHALL BE FREE OF DISTORTION. A DEFLECTION OF MORE THAN 1/8" RELATIVE TO ADJACENT PANELS WILL BE EJECTED. ALL JOINTS 1/8" MAXIMUM, FILL WITH BLACK SEALANT. A. IF SAFETY GLASS IS REQUIRED BY CODE, GLAZING SHALL BE AS MFG. BY PPG OR APPROVED EQUAL. 7.22 GLASS PANEL SIZES AND JOINTS SHALL BE APPROVED BY SB. 7.23 DOOR HARDWARE SHALL BE SUPPLIED BY G.C. 7.24 HARDWARE WILL BE SPECIFIED BY ARCHITECT. SPECIFICATIONS SHOULD BE THE BEI IER OF BUILDING STANDARD OR EQUIVALENT IN QUALITY AND FUNCTION TO THE FOLLOWING: GENERAL PROVISIONS 1 LIGHTING DESIGNER/ OWNERS LIGHTING REPRESENTATIVE SHALL MEAN THE PARTY RESPONSIBLE FOR THE DESIGN OF THE LIGHTING SYSTEM. 2. ELECTRICAL CONTRACTOR TO INSTALL ALL FACILITY LIGHTING AND WORK LIGHTING AS SHOWN AND SPECIFIED IN ELECTRICAL ENGINEERING DRAWINGS AND SPECIFICATIONS. 3. PROVIDE ALL MATERIAL AS DETAILED ON DRAWINGS AND/OR SCHEDULES, AND LABOR AS REQUIRED TO ARCHIVE A COMPLETE AND OPERATING LIGHTING SYSTEM. COORDINATE AND OBTAIN APPROVALS FROM ALL RESPECTIVE UTILITY COMPANIES OR REGULATORY AGENCIES AS REQUIRED FOR A COMPLETE AND OPERATING INSTALLATION. 5. ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH ALL LOCAL, NATIONAL, AND SEISMIC GOVERNING CODES. WORK NOT IN CONFORMANCE WITH APPLICABLE CODES SHALL BE BROUGHT INTO COMPLIANCE AT NO ADDITIONAL COST TO THE OWNER. 6. ALL ELECTRICAL MATERIAL AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED. ALL EQUIPMENT SHALL BE LISTED, LABELED OR CERTIFIED B A NATIONALLY RECOGNIZED TESTING LABORATORY. 7. ALL EQUIPMENT SHALL BE FACTORY TESTED TO ENSURE PROPER OPERATION PRIOR TO SHIPMENT TO JOB SITE. 8. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL PERMITS AND INSPECTION FEES. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO SCHEDULE ALL ELECTRICAL INSPECTIONS REQUIRED BYE THE BUILDING DEPARTMENT AND SERVING UTILITIES. 9. ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP RELATED TO THE ELECTRICAL INSTALLATION FOR A MINIMUM PERIOD OF ONE YEAR FROM THE DATE WHICH THE OWNER ACCEPTS THE FINISHED PROJECT. ANY DEFECTS IN MATERIALS OR WORKMANSHIP DURING THIS GUARANTEED PERIOD SHALL BE CORRECTED BY THE ELECTRICAL CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER OR TENANT. 10. ELECTRICAL CONTRACTOR SHALL VISIT SITE, TO VERIFY ALL EXISTING CONDITIONS TO BE ENCOUNTERED IN THE INSTALLATION OF ALL NEW EQUIPMENT, LUMINAIRES, DEVICES, FEEDERS, ETC. EXACT INSTALLATION METHOD AND REQUIREMENTS SHALL BE VERIFIED AND DETERMINED PRIOR TO BID DATE. ELECTRICAL CONTRACTOR SHALL IMMEDIATELY NOTIFY LIGHTING DESIGNER/OWNERS LIGHTING REPRESENTATIVE OF ANY REQUIRED MODIFICATIONS THAT ARE NOT SHOWN ON HE DRAWINGS. SUBMITTAL OF ALL BID INDICATES ELECTRICAL CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PERFORMED. 11. ALL EQUIPMENT, ELECTRICAL CHARACTERISTICS, LOCATIONS AND CONNECTION REQUIREMENTS SHALL BE VERIFIED PRIOR TO ANY ROUGH -IN WORK. 12. COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH NEC REGULATIONS. 13. ELECTRICAL CONTRACTOR SHALL BE LICENSED BY THE JURISDICTION WHERE THE PROJECT IS LOCATED AND CAPABLE OF EMPLOYING THE PROPER LABOR FORCE NECESSARY TO COMPLETE THE INSTALLATION AS INSTRUCTED BY THE OWNER. 14. PROVIDE SHIPMENT OF ALL LIGHTING AND RELATED EQUIPMENT TO BE DELIVERED TO THE JOB SITE. 15. DELIVERY OF EQUIPMENT TO THE JOB SITE SHALL BE IN CLEARLY IDENTIFIED CRATES, CARTONS, OR APPROPRIATE SHIPPING CONTAINERS AS TO ITEM, QUANTITY, AND INSTALLATION LOCATION 1 6. EMERGENCY WARRANTY REPAIRS SHALL BE PERFORMED WITHIN TWENTY-FOUR (24) HOURS OF NOTIFICATION WHEN A SYSTEM OR COMPONENT MALFUNCTIONS DURING USE. 17. ALL WARRANTY REPAIRS SHALL BE PERFORMED BY QUALIFIED PERSONNEL IN THE REGULAR EMPLOY OF THE MANUFACTURE AND SHALL NOT BE SUBCONTRACTED OR ASSIGNED WITHOUT THE WRITTEN CONSENT OF THE OWNER. IN NO CASE SHALL THE MANUFACTURE BE RELIEVED OF RESPONSIBILITY FOR THE PERFORMANCE OF WARRANTY REPAIRS. 18. THE ELECTRICAL CONTRACTOR SHALL NOTIFY LIGHTING DESIGNER/OWNERS LIGHTING REPRESENTATIVE OF ANY PROVISION OF THIS SPECIFICATION THAT IS IN CONFLICT WITH LOCAL OR NATIONAL CODES AND AN ADDENDUM SHALL BE ISSUED TO CORRECT THE SPECIFICATION. LOCAL OR NATIONAL CODE WILL TAKE PRECEDENCE. 19, ALL MEASUREMENTS FOND IN LIGHTING PLANS ARE APPROXIMATE. ELECTRICAL CONTRACTOR IS REQUIRED TO MAKE FIELD MEASUREMENTS BASED ON ACTUAL SITE CONDITIONS TO DEVELOP COMPLETE ORDERS AND INSTALL SYSTEMS PER DRAWINGS AND SPECIFICATIONS. 20. EMERGENCY EGRESS LIGHTING SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR IN CONSULTATION WITH THE LIGHTING DESIGNER/OWNER LIGHTING REPRESENTATIVE. ANY LIGHTING LUMINAIRE - USED ALSO AS EMERGENCY LIGHTING LUMINAIRES- MUST RETAIN CONT ROL AS DEFINED BY LIGHTING DESIGNER/OWNER'S LIGHTING REPRESENTATIVE TO ENSURE DESIGN INTENT IS MAINTAINED. 21. ELECTRICAL CONTRACTOR SHALL PROPERLY "RING -OUT" AND VERIFY ALL CIRCUITRY, DIMMING, AND CONTROL PRIOR TO TEST AND ADJUST/COMMISSIONING PHASE COMMENCING. 22. ELECTRICAL CONTRACTOR TO REFER TO INTERIOR, EXTERIOR, ARCHITECTURAL, LIGHTING, SCENIC DRAWINGS, AND SPECIFICATION PACKAGES FOR ALL MOUNTING HEIGHTS AND DETAILS FOR SPECIAL MOUNTING REQUIREMENTS. 23. ELECTRICAL CONTRACTOR SERVICES SHALL INCLUDE NECESSARY COORDINATION WITH ENGINEERING AND PROJECT MANAGEMENT TO INTERFACE WITH OWNER, CONSULTANTS, ARCHITECTS, OTHER CONTRACTORS AND ALL OTHER PARTIES NECESSARY TO PROVIDE A COMPLETE AND WORKING LIGHTING SYSTEM. 24. ELECTRICAL CONTRACTOR SHALL REQUEST COPIES OF LIGHTING DESIGN PAPERWORK, INCLUDING BUT NOT LIMITED TO INSTRUMENT SCHEDULES, MEDIA AND ACCESSORY REPORTS, AND LUMINAIRE SPECIFICATIONS THAT SUPPLEMENT CAD LUMINAIRE SCHEDULE 25. LIGHTING LUMINAIRES SHALL NOT BE USED AS WORKLIGHTS DURING CONSTRUCTION AND SHALL BE FULLY OPERATIONAL AT THE TIME OF ACCEPTANCE BY OWNER OR TENANT. 26. FINAL LOCATION OF LIGHT LUMINAIRES TO BE CONFIRMED ON SITE BY OWNER'S LIGHTING DESIGNER. 27. LIGHTING LAYOUT DRAWINGS ARE DOCUMENTED TO ACHIEVE THE DESIGN INTENT. INSTALLATION DETAILS SHALL BE PROVIDED IN THE ARCHITECTURAL. ELECTRICAL ENGINEERING INFORMATION SHALL BE PROVIDED IN THE ELECTRICAL ENGINEERING DRAWINGS. THE MECHANICAL ENGINEER IS TO REVIEW THE LIGHTING LAYOUT TO VERIFY THAT NO CONFLICT EXISTS BETWEEN MECHANICAL SYSTEMS AND LIGHTING EQUIPMENT. 28. ELECTRICAL CONTRACTOR TO RUN ALL CONDUIT IN AS DISCREET A MANNER AS POSSIBLE (I.E., TO USE "OFF-STAGE" POSITIONS) TO KEEP IT HIDDEN FROM GUEST VIEW WHILE MAINTAINING ACCESSIBILITY. 29. ELECTRICAL CONTRACTOR TO PAINT -OUT ALL EXPOSED CONDUIT TO MATCH BUILDING AS REQUIRED BY OWNER. 30. ELECTRICAL CONTRACTOR TO REHABILITATE, REPAIR, RELAMP AND REPLACE AS REQUIRED ALL EXISTING EQUIPMENT TO BE USED AS A PART OF THE NEW DESIGN TO ENSURE EQUIPMENT IS COMPLETELY OPERATIONAL AND FUNCTIONAL. INSTALLATION 1. THE DRAWINGS ARE DIAGRAMMATIC AND REPRESENT THE DESIGN INTENT OF THE EQUIPMENT, DEVICES, ETC. TO BE CONNECTED AND THE CIRCUITS TO WHICH THEY ARE TO BE CONNECTED. ELECTRICAL CONTRACTOR SHALL INSTALL ALL CONDUIT, J-BOXES, ETC., AS REQUIRED FOR A COMPLETE AND FULLY OPERATING SYSTEM. 2. PENETRATIONS OF ALL FIRE -RATED WALLS OR CEILINGS SHALL BE IN ACCORDANCE WITH ALL LOCAL AND NATIONAL CODES. 3. ELECTRICAL CONTRACTOR SHALL INCLUDE ALL MISCELLANEOUS ITEMS REQUIRED TO COMPLETE WORK AND MAKE LUMINAIRE AND LIGHTING SYSTEMS FULLY OPERATIONAL. 4. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR AND PROVIDE TEMPORARY ELECTRIC SERVICE. 5. ELECTRICAL CONTRACTOR SHALL PROVIDE OWNER WITH TWO (2) SETS AND LIGHTING DESIGNER ONE (1) SET OF ELECTRICAL "AS-BUILTS" UPON COMPLETION OF JOB. 6. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MATERIAL SAFETY DATA SHEETS REQUIRED. 7. ELECTRICAL CONTRACTOR SHALL PROVIDE ON-LINE AC POWER PROTECTION TO AVOID CHANGES IN VOLTAGE, IF REQUIRED, AT THE SITE. 8. LIGHTING DESIGNER OR ARCHITECT SPECIFICALLY RESERVES THE RIGHT TO RELOCATE ANY EQUIPMENT OR OUTLET AT NO INCREASE IN CONTRACT COST PRIOR TO ITS INSTALLATION (IN CASE OF STANDARD PRODUCT) OR RELEASE FOR MANUFACTURE (IN THE CASE OF CUSTOM PRODUCT), REGARDLESS OF PRIOR SHOP OR DESIGN DRAWING REVIEW. 9. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ROUGH AND FINAL AIMING AND FOCUS OF ALL LIGHTING LUMINAIRES AS DIRECTED BY LIGHTING DESIGNER / OWNERS LIGHTING REPRESENTATIVE DURING TEST, ADJUST, AND COMMISSIONING PHASE. 10. UNLESS OTHERWISE SPECIFIED, MOUNTING CONDITIONS ARE TO BE DETERMINED BY ELECTRICAL CONTRACTOR FOR EACH LUMINAIRE TYPE. ELECTRICAL CONTRACTOR MUST SUBMIT RECOMMENDED APPROACHES TO ARCHITECT AND LIGHTING DESIGNER/OWNERS LIGHTING REPRESENTATIVE FOR APPROVAL PRIOR TO PURCHASING AND INSTALLATION. 11. ELECTRICAL CONTRACTOR TO VERIFY LUMINAIRE MOUNTING HARDWARE IS COMPATIBLE WITH APPROVED MOUNTING CONDITIONS. MOUNTING CONDITIONS MUST ALLOW FOR AIMING AND ADJUSTING OF 'LUMINAIRES ON SITE DURING TEST AND ADJUST/COMMISSIONING PHASE. 12. ELECTRICAL CONTRACTOR TO SUPPLY FOLDING TABLE FOR LIGHTING CONSOLE, AND MINIMUM OF TWO (2) CHAIRS FOR LIGHTING DESIGNER(S) AND PROGRAMMER(S) DURING ENTIRE TEST AND ADJUST/COMMISSIONING PHASE. 13. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL COLOR MEDIA, LENSES, TEMPLATES AND ACCESSORIES AS SPECIFIED IN INSTRUMENT SCHEDULE AND LUMINAIRE SCHEDULE. 14. ELECTRICAL CONTRACTOR TO SUPPLY ONE (1) LAPTOP COMPUTER WITH ALL NECESSARY LIGHTING CONTROL SOFTWARE FOR PROGRAMMING DURING TEST AND ADJUST/COMMISSIONING PHASE. EXECUTION 1. PROTECT ALL WALLS, TRIM, FLOORS, EQUIPMENT UTILITY LINES AND MATERIALS. WHEN WORKING ON FINISHED SURFACES, LIMIT DAMAGE TO THE CONFINES AS MUCH AS POSSIBLE AND RESTORE TO THE ORIGINAL CONDITION ALL SURFACES THAT ARE DAMAGED BECAUSE OF THE INSTALLATION OF THE WORK. 2. EQUIPMENT, MATERIALS AND SUPPLIES PREVIOUSLY INSTALLED BUT REMOVED FOR PROTECTION SHALL BE REPLACED IN ORIGINAL LOCATIONS. ANY MATERIALS DAMAGED SHALL BE REPLACED WITH NEW MATERIALS OF LIKE KIND AND QUALITY. 3. DO ALL DRILLING, CUTTING, CHANNELING AND PATCHING REQUIRED TO INSTALL ELECTRICAL WORK AS INDICATED OR HEREIN SPECIFIED. ALL HOLES, CURBS, ETC., IN FLOORS, CEILINGS, AND WALLS SHALL BE PATCHED, UNLESS INDICATED OTHERWISE. 4. ALL CONDUIT RUNS SHALL BE CONCEALED UNLESS SHOWN OTHERWISE. PROVIDE A PULL LINE IN ALL EMPTY CONDUITS. 5. EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND VISUAL FIELD SURVEY AND ARE SHOWN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT SITE. 6. ELECTRICAL CONTRACTOR TO SUPPLY A MINIMUM OF TWO ELECTRICIANS FOR EACH LIGHTING DESIGNER/OWNERS LIGHTING REPRESENTATIVE DIRECTING FOCUS DURING THE TEST AND ADJUST/COMMISSIONING PHASE (AKA FOCUS AND PROGRAMMING). IBEW ELECTRICIANS TO BE MINIMUM JOURNEYMAN LEVEL EXPERIENCE, THEATRICAL ELECTRICIANS TO HAVE A MINIMUM OF 2 YEARS FIELD EXPERIENCE. ELECTRICAL CONTRACTOR MUST SUPPLY ADEQUATE SUPPORT INCLUDING LADDERS, LIFTS OR OTHER EQUIPMENT REQUIRED TO ACCESS LUMINAIRES AT THE TIME FOR FOCUS, INCLUDING EVENING OR NIGHT WORK AS MAY BE REQUIRED DUE TO SCHEDULE CONFLICT OR DAYLIGHT IMPACT. ELECTRICAL CONTRACTOR TO HAVE ALL NECESSARY EQUIPMENT AVAILABLE THROUGHOUT TEST AND ADJUST/COMMISSIONING PHASE INCLUDING, BUT NOT LIMITED TO: A. STANDARD CONTRACTOR ELECTRICIAN HAND TOOLS. B. SOCKET SET. C. CLEAN RAGS TO WIPE LENSES. D. SPARE LAMPS FOR LUMINAIRES BEING FOCUSED. E. LADDERS OR OTHER MEANS OF ACCESS TO AREAS BEING FOCUSED. F. SAFETY HARNESSES OR OTHER DEVICES AS REQUIRED. SUBMITTALS 1. ELECTRICAL CONTRACTOR TO SUBMIT FOR APPROVAL ON THE PRODUCTS HE INTENDS TO FURNISH WITHIN SEVEN (7) DAYS OF AWARD OF CONTRACT. FAILURE TO SUBMIT WITHIN DEADLINE CONSTITUTES A GUARANTEE THAT ONLY THE BASE SPECIFIED PRODUCTS WILL BE SUPPLIED AND THAT NO OTHER PRODUCTS, WHETHER LISTED AS ALTERNATES OR NOT, WILL BE CONSIDERED. 2. REQUESTS FOR APPROVAL OF NON -SPECIFIED PRODUCTS MUST BE ACCOMPANIED BY THE FOLLOWING AT LEAST FIVE (5) BUSINESS DAYS IN ADVANCE OF THE BID SUBMITTAL DATE. A. SPECIFICATION DATA SHEET COMPLETE WITH MANUFACTURER NAME CONTACT INFORMATION AND SPECIFIED MODEL NUMBER. B. A LIST OF COMPARABLE PROJECTS WHERE THE PRODUCT HAS BEEN USED IN THE LAST TWO (2) YEARS. C. SAMPLE OF PRODUCT. THESE ITEMS SHALL BE APPROVED BY LIGHTING COMMENCEMENT OF PLACING ORDERS OR P 3. MANUFACTURERS OF SUBMITTED PRODUCTS MUS AND IN NO INSTANCE WILL THIS PROJECT BE T, PRODUCT IF IT IS NOT LISTED ON THE SPECIFIM DESIGNER OR ARCHITECT, PRIOR ROUGH -IN WORK. 14'1 ON F SW OFTJ F A TO ANY (5) YEARS TION OF THIS 4. ELECTRICAL CONTRACTOR SHALL ALLOW PROPER ORDERING,WallaROCUREMENT OF LUMINAIRES. LIGHTING DESIGNER SHALL BE NOTIFIED OF ANY PRODUCT SUBSTITUTIONS AS A RESULT OF DELIVERY, PRIOR TO ORDERING ALTERNATE PRODUCT. FAILURE TO ORDER LUMINAIRES WITH ADEQUATE LEAD-TIME TO MEET THE INSTALLATION SCHEDULE DOES NOT RELIEVE THE ELECTRICAL CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE THE SPECIFIED PRODUCT WITHOUT COMPENSATION TO THE OWNER. 5. SHOULD A MANUFACTURER FAIL TO DELIVER A PRODUCT THAT HAS BEEN ORDERED WITHIN REASONABLE LEAD-TIME, ELECTRICAL CONTRACTOR SHALL NOTIFY LIGHTING DESIGNER WITH A PROPOSED ALTERNATE LUMINAIRE. LIGHTING DESIGNER SHALL MAINTAIN FINAL AUTHORITY FOR AUTHORIZATION OF ANY SUBSTITUTION. 6. LAMPS AND ANY ACCESSORIES SPECIFIED SHALL BE INCLUDED IN THE SUBMITTAL PACKAGE FOR ALL LUMINAIRES. 7. ELECTRICAL CONTRACTOR SHALL PROVIDE FOUR (4) COMPLETE MAINTENANCE MANUALS INCLUDING, BUT NOT LIMITED TO: A. REQUIRED MAINTENANCE CHECK -OFF SCHEDULE. B. ORIGINAL MANUFACTURER'S EQUIPMENT (OME) TECHNICAL DATA SHEETS. C. DETAILED OPERATING PROCEDURES. D. A LIST OF RECOMMENDED SPARE PARTS AND LAMPS. E. INSTALLATION WIRING DIAGRAMS. F. SHOP DRAWINGS G. INSTALLATION AND/OR CONSTRUCTION AS -BUILT DRAWINGS. 8. DUE TO THE FAST TRACK NATURE OF THIS PROJECT, SUBSTITUTIONS FOR SPECIFIED LIGHTING PRODUCTS ARE NOT ACCEPTABLE AND WILL NOT BE CONSIDERED. FAILURE TO INCLUDE ONE OF THE SPECIFIED PRODUCTS AS A PART OF THE BASE BIDE MAY, AT THE DISCRETION OF THE OWNER, RESULT IN CONTRACTOR BEING EXCLUDED FROM FURTHER CONSIDERATION AND INVALIDATE ENTIRE LIGHTING BID. 9. SUBMITTAL TO INCLUDE SPREADSHEET DETAILING LUMINAIRE TYPES, MANUFACTURER NAMES AND MODEL NUMBERS, LAMPING, ACCESSORIES, AND CURRENTLY QUOTED LEAD TIMES FOR DELIVERY OF ALL PRODUCTS TO BE BE PROVIDED. FOR ALL PRODUCTS WITH LONG LEAD TIMES, WHICH MAY ADVERSELY IMPACT THE CONSTRUCTION SCHEDULE, PROVIDE A MINIMUM OF TWO (2) ALTERNATE EQUIVALENT PRODUCTS FOR THE OWNER'S REVIEW AND APPROVAL. NO PRODUCTS SHALL BE PROCURED WITHOUT WRITTEN APPROVAL OF THE SUBMITTALS. LUMINAIRE SPECIFICATIONS 1. ALL LIGHTING LUMINAIRES AND DEVICES SHALL BE MOUNTED AND SUPPORTED IN ACCORDANCE WITH APPLICABLE SAFETY STANDARDS AND ALL NATIONAL AND LOCAL ELECTRICAL CODES. 2. ALL EXTERIOR EQUIPMENT SHALL BE RATED FOR WET LOCATION AND THE IP RATING OF ALL EQUIPMENT SHALL CONFORM TO THE CONDITIONS IN WHICH THE LUMINAIRE IS MOUNTED. 3. ELECTRICAL CONTRACTOR SHALL PROVIDE LUMINAIRE-MOUNTING KITS AS REQUIRED TO SUIT THE EXACT TYPE OF CEILING OR CONDITION TO WHICH THEY ARE MOUNTED. 4. ALL LUMINAIRES SHALL BE SUPPLIED WITH COLOR FILTERS AND ACCESSORIES AS REQUIRED. 5. ALL REMOTE STEP-DOWN TRANSFORMERS, DRIVERS AND POWER SUPPLY UNITS ARE TO BE LOCATED AS NEAR THE LUMINAIRE AS POSSIBLE, HIDDEN FROM GUEST VIEW IN AN ACCESSIBLE COMPARTMENT THAT IS WELL VENTILATED TO PROVIDE HEAT DISSIPATION. 6. ALL TRANSFORMERS SHALL BE FUSED ON THE SECONDARY SIDE. 7. ELECTRICAL CONTRACTOR TO SUPPLY LAMPS ONLY FROM APPROVED LAMP MANUFACTURERS. APPROVED MANUFACTURERS: GENERAL ELECTRIC, PHILIPS, OSRAM SYLVANIA, USHIO, VENTURE, OR EQUIVALENT ALTERNATE SUBMITTED FOR APPROVAL BY LIGHTING DESIGNER. 8. COLOR FILTERS SHALL BE GLASS, DICHROIC OR FADE -NOT AS SPECIFIED UNLESS OTHERWISE INDICATED ON DRAWINGS OR LIGHTING DOCUMENTATION PACKAGE. ALL GLASS AND DICHROIC FILTERS SHALL INCLUDE MESH FRAMES AND SAFETY CABLES PER OWNER OVERHEAD SAFETY SPECIFICATIONS, 9. COLOR TO BE CONFIRMED WITH LIGHTING DESIGNER/OWNERS LIGHTING REPRESENTATIVE PRIOR TO ORDERING. 10. ELECTRICAL CONTRACTOR TO VERIFY ALL LUMINAIRES SPECIFIED WITH A COLOR FILTER ARE SUPPLIED WITH ANY AND ALL ATTACHMENT DEVICES FOR THE FILTER. THIS INCLUDES FRAMES, SNAP RINGS, ATTACHMENT HARDWARE AND/OR FILTER STANDOFFS. ALL ATTACHMENT HARDWARE MUST BE SUBMITTED BY SUPPLIER FOR REVIEW PRIOR TO ORDERING OF LUMINAIRE. REVIEW AND APPROVAL SHALL BE BY LIGHTING'DESIGNER/OWNERS LIGHTING REPRESENTATIVE. .... 11. ELECTRICAL CONTRACTOR TO VERIFY ALL LUMINAIRES SPECIFIED WITH A TEMPLATE (PATTERN OR "GOBO") ARE SUPPLIED WITH ANY AND ALL ATTACHMENT DEVICES FOR THE PATTERN. THIS INCLUDES PATTERN HOLDERS, SNAP RINGS, AND/OR INSTALLATION HARDWARE. ELECTRICAL CONTRACTOR TO VERIFY SIZE AND TYPE OF TEMPLATE MATERIAL IN CONJUNCTION WITH LUMINAIRE SPECIFICATIONS AND LIGHTING INSTRUMENT SCHEDULE. ALL ATTACHMENT HARDWARE MUST BE SUBMITTED BY SUPPLIER FOR REVIEW PRIOR TO ORDERING OF TEMPLATE AND HARDWARE. REVIEW AND APPROVAL SHALL BE BY LIGHTING DESIGNER/OWNERS LIGHTING REPRESENTATIVE. 12. ELECTRICAL CONTRACTOR TO PROVIDE LAMPS FOR ALL LUMINAIRES IN FULL CASES TO EXCEED THE NUMBER REQUIERED BY NO LESS THAN 10%. 13. ELECTRICAL CONTRACTOR TO REPLACE ALL BURNED OUT OR INOPERATIVE LAMPS AT THE END OF THE CONSTRUCTION PHASE PRIOR TO TEST AND ADJUST/COMMISSIONING PHASE AND AGAIN PRIOR TO OWNER OCCUPANCY OR PROJECT OPENING. 14. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL LUMINAIRE TYPES AS SHOWN AND SPECIFIED IN DRAWINGS AND SPECIFICATIONS. 15. ALL EQUIPMENT SHALL BE U.L. LISTED OR EQUIVALENT AND MUST BE RATED TO CONFORM TO THE CONDITIONS IN WHICH LUMINAIRE IS MOUNTED. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 201B City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUCW:ILA NOV 2 6 2018 PERMIT CENTER CallisonRTKL, Inc. The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 Tel: 212.354.9240 Fax: 212.354.9253 CallisonRTKL Project No: 003-160285.00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817.938.5860 www.bowlero.com Consultant Henderson Engineers, Inc. 8345 Lenexa Drive Suite 300 Lenexa, KS 66214 Tel: 913.742.5000 www.hei-eng.com Issued for Permit Client/Owner/Project Address Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Project Address 100 Andover Park W 00, Tukwila, WA 98188 Issue Drawing Log 11/9/2018 ISSUED FOR PERMIT Seal Sheet Identification GENERAL NOTES PARETAILINYCI8OWLER0104-PROJECTSTUKW1LA, WAI1.4 ARCHITECTURE12-CAD1A-CONTRACT DRAWINGS/NEW SHEETS 6 3:59:29 PM © 2016 CallisonRTKL Inc. REFERENCE SYMBOLS ACCESSIBILITY CLEARANCES XX XX XX I CLEARANCES AT CORRIDORS � 4 21" MAX. 1.5" 0 RAIL (SS OR CHROME) 1.5" 0 RAIL (SS OR CHROME) (b) H •35 M 1- ' . is ALTERNATE STALLS �ZF **Ng 1.5 1' 6 18" , ,ip m OILET 1.5 L 1 1 a ► v �� o to ¢ z ¢ �I „cO T.P. i f CONTROL AREA i x . I �,Q �o AXXX AXXX BUILDING SECTION INDICATOR AXXX WALL SECTION INDICATOR L�L_e..- _ ` C: o F Lo n X - II IIYt : M (O tD V grFAM FIG. 35 it t� 1525 MM g SHOWER SIZE AND CLEARANCES SIDE WALLS -'� I. WHEELCHAIR TURNING SPACE ��'I a 3' XX N BACK ¢ SEAT WALL BACK CONTROL WALL SEAT WALL A-XXX \,.._ -. ---1 XX 36" 48" 36" / / 0" 2'-6" / O 36" BY STALL GRAB BARS AT SHOWER STALLS 915 MM 1219 MM 915 MM 42" MIN. X 42" MIN. I / / OILET q a io NOTE SHOWERHEAD AND CONTROL AREA 1067 MM 1067 MM I I ► tr MAY BE ON BACK (LONG) WALL f ( '� � �r • (AS SHOWN) OR ON EITHER SIDE WALL WIDTH OF ACCESSIBLE ROUTE FOR 90' TURN WIDTH ACCESSIBLE ROUTE FOR TURNS AROUND AN ( , ;' OBSTRUCTION / L 27" MAX. 12" 36" 12" _ __I_ I I� ( ( 48" MIN. 0 2 -6" M ♦ © 915 MM / -I REAR WALL OF( CONTROL ARFA 1219 MM OS 30 S)TANDARD STALL 48" MIN. U M MM (a) (b) (�) (a) XX � Il // u CLEAR FLOOR SPACE PARAL APPROACH HIGH AND LOW SIDE REACH REACH LIMITS MAXIMUM OVER OBSTRUCTIONS SIDE REACH 36" BY 36" STALLL 1A_XXX EXTERIOR ELEVATION INDICATOR © INTERIOR ELEVATION INDICATOR it ��, III z SIDE = in •aw 4' X � % a / i a� NIz 1 BACK (LONG} SIDE ,y/ • ~ LINE1 p \ CL_� �I ��`32" a 36" BY 60" STALLI I Z // cv �/► MINIMUMMATCH r� rn 'n ^° i N61 jWt rsh4' Ec�i�ji1Earl Eqi,TOILET w o M z 17 Ml SEE XX/A-XXX ///// 7/I iM Ir TOILET z. 4' , a. c MATCH LINE INDICATOR DRAWING REVISION INDICATOR .=-_-_----, I (o) HIGH FORWARD REACH LIMIT (b) MAXIMUM FORWARD REACH OVER AN OBSTRUCTION !_ : MINIMUM PASSAGE WIDTH FOR ONE WHEELCHAIR AND QNET-SHAPED SPACE FOR 180' TURHNS FIG. 2 Z CLEAR AMBULATORY PERSON FORWARD REACH "�� •x FLOOR rilACE 6.-2" CLEAR m - o N m SPACE WHEELCHAIR OF FINISH FACE OF FINISH z z ', I SIDE PUSH SIDE TURNINGy 5'a o UPULL '---- _ X.X X.X X:X X.X X SPACE 5 Nn i (TYP.) (a_1} NI9" r,„,„„ , STANDARD STALL (END OF ROW}TOE STANDARR6 STALL MAX___= 1-71525 MM (455 MM) MIN. r i - �� 48" MIN. 483 MM 24" (610 MM) "cJ.., pf,, "o Z KNEE CLEARANCE 8" MIN. CLEARANCE18" 6" MAX. i �� `i 17"-19 203 MM 152 MM /11111 EL XXX.XX XXX'-XX" a N OR DEPTH A _ �LAVA1 7" M N. �- LAVATORY CLEARANCES DATUM INDICATOR OR WORK POINT /EL SPOT ELEVATION INDICATOR CLEARANCE AT WATER CLOSET MANEUVERINGm. CLEARANCE AT o w l _ E I CLEAR N FLAR NOTE: X = 12" MIN.(305 MM)"� {TYP.) DOORS (TYP.) r)- 1�. - ro n SPACE IF THE DOOR HAS BOTH A `� � CLOSER AND A LATCH. �e ! �� I--- oUNTER `\ I �P� � ry FRONT APPROACHES - SWINGING DOORS • I C`� WATER I I KNEE CLEARANCE ��� TOE CLEARANCE 30„762NMM r- I CLOSET 60" 1'-6" MIN.iii 1'-12" MAX. E XXXXX EQUIPMENT INDICATOR <I 5 I W X 56 D 203 MM 152 MM <XIXXXXX> FIXTURE INDICATOR PULL SIDE PUSH SIDE I I I 54" MIN. COAT HOOK I _i _J -, FOUNTAIN DEPTH ROOM NAME i y 1370 MM FF J i---J 17 19 610 MMr 48" MIN. 2022 <FIXXXXX> FURNITURE INDICATORI t ----� {TYP.}48" - - -I- 431-483 30 MIN. 1220 MM M v <GIXXXXX? GRAPHIC/SIGNAGE INDICATOR I I z m MM P a0 I r I 22I DOOR 48" X I 762 MM \ ROOM INDICATOR MISCELLANEOUS INDICATORS X N a ( ,- ALTERNATE (W + 12") DRINKING FOUNTAINS AND WATER COOLER CLEARANCES \ 1 0 - I MIN. DOOR LOCATION OUTSWINGING BASE HEIGHT CABINET HEIGHTS /36" 914 MM DOOR SPOUT SHALL BE WITHIN 3" OF' FRONT 18 18" MIN. 42" MIN. 18" `���\ AND SHALL DIRECT FLOW FLOW SHALL BE A MINIMUM PARALLEL TO FRONT OF 4" HIGH 0220 (FIXXXXXXX) NOTE: �455/45 17"-19" X = 36" (915 MM) MIN. IF Y = 60" (1525 MM) MM MM �'�' tee ►�i 9" (DOOR) OPENING INDICATOR FINISH INDICATOR X = 42" (1065 MM) MIN. IF Y = 54" (1370 MM) NOTE: .aryercx e x«.. tan �aa Gpll►�� - ►N ► . 4 Y = 48" (1220 MM) MIN. IF ,. I M ' ..� �� DOOR HAS BOTH A LATCH AND A Z , ( 1 I I q��� . .� -�t-- ♦►i� • �►���i ��►y��� CLOSER. l 1 I f(t} z //�� ►�� i �� VW tJ % V �i+ HINGE SIDE APPROACHES - SWINGING DOORS rxammAli il 1 I 4' NOTE: R ALL DOORS COMPLYCLEAR° IN ALCOVES SHALL WITH THE LOORI a CLEARANCES FOR FRONT APPROACHES. SPACE MIN. MAX. _ • (XX'--XX” AF� PULL SIDE X=24" N. X=24" MIN. PUSH SIDE 4 i _ A13 a 1 nx MIN. EQUIPMENT SECTION DRINKING FOUNTAIN PERMITTED THRU IN SHADED PLAN AT DRINKING FOUNTAIN AREA - g , ���� 12Qid; WINDOW INDICATOR CEILING HEIGHT INDICATOR �...._ - 610 M _ 610LJ60" M - - - -"� 48" MIN. 1524 MM (a) HEIGHT SKNEE FIG. 27 (b) MATERIAL (PER FINISH LEGEND) FINISH (PER FINISH LEGEND)oo z 1219 MM / CLEARANCE AT WATER CLOSET POSSIBLE WAIL LOCATIONS CLEARANCEPOUT CLEAR FLOOR SPACE g I I I I a ,-I\ i >-- IXXIXXIXX XX -XX AFF WALL END OR EDGE e WALL END EDGE WALL TYPE INDICATOR HEIGHT CEILING HEIGHT/MATERIAL/FINISH INDICATOR W m (WHERE OCCURS) OR NOTE: , > (WHERE OCCURS) Y = 54" (1370 MM) MIN. IF THE m�r> 0=4 w WALL SEGMENT 24" WIDE OR LESS DOOR HAS A CLOSER. ¢ m o i _ NOTES: NOTE: 48" (1220 MM) MIN. IF THE _ zoo a DOOR FRAME OR FIRE ALARM 1. USE THIS DETAIL TO LOCATE DEVICES EQUAL EQUAL (NON -RATED PARTITION) DOOR HAS A CLOSER. N m w WINDOW FRAME THAT ARE INDICATED ON THE DRAWINGS , (1 HOUR RATED PARTITION)q� z �-.w¢� ¢v ¢ BTO UT NOT LNOT LOCATED BY DIMENSION, OR - (2-HOUR RATED PARTITION) LATCH SIDE APPROACHES - SWINGING DOORS E c THEE w wo W > ' ' w m ' w ARE INDICATED ON DRAWINGS. - - - - (3-HOUR RATED PARTITION) W LL W L �> w CC a a / 6 , THERMOSTAT OR 2. ALIGN MULTIPLE HORIZONTALLY DEVICES AND/OR VERTICALLY AS x WINDOW, DCOR OR KEYNOTE - - (4-HOUR RATED PARTITION) PARTITIONS TEMPERATURE SENSOR DETAILED. "FEATURE" THAT c ti Ara C ' ITEMS OTHER THAN ELECTRICALINTO SEPARATES SEGMEUTS WALL © j ('� �+ ADA GENERAL NOTES \3. DOORPTACLES SHALL BE MOUNTED NASA k OR INTERSECTING WALLS AS • z o - ::a�^--TELEPHONES, DETAILED SO WITH THE AS NOT TO INTERFERE PLACEMENT OF ART OR - -DOORWAYS - g o ' DOOR SWITCHES, DOOR - CONTROLLERS, FIRE ALARM PULL «, Lo FURNITURE -- EXCEPT THAT WHERE 1. THE CONDITIONS ILLUSTRATED ON THIS SHEET CONSTITUTE LEGAL STANDARDS FOR HANDICAPPED ACCESSIBILITY. THEY DO NOT CONSTITUTE ACTUAL ARCHITECTURAL CONDITIONS FOR CONSTRUCTION IN THE COURSE OF THIS WORK. SEE ENCLOSED ARCHITECTURAL DRAWINGS FOR ACTUAL EXTENT OF WORK. NOT ALL CONDITIONS SHOWN HERE OCCUR IN THIS PROJECT. 2. CONTRACTOR TO INFORM ARCHITECT WHEN DUE TO FIELD CONDITIONS, C. ACTUAL CONSTRUCTION WILL NOT CONFORM TO THESE STANDARDS. 3. REFERENCE CURRENT ANSI STANDARDS. e„ {� JJ. E ` " CO N N \ 2" 2° - SWITCHES, LIGHT SWITCHES AND SIMILAR ITEMS (THE INTENT IS TO THE WALL 9/32 WIDE, SEGMENT IS LESS THAN 24 CENTER THE DEVICES AS 2° ALIGN TOPS OF ALL ITEMS WHILE _ DETAILED. W - - ALLOWING ALL OPERABLE PARTS TO o BE LESS THAN 4' 0" AFF) CL OF SINGLE DEVICE OR CLl r _ _ . ,- ELECTRICAL RECEPTACLES - SINGLE, GANGED, OR SEPAPARATED BY 2" -' - " , TWO HINGED DOORS IN SERIES \ \ \ 2 D OVNT I C [ MOUNT \ G G L D E LI \=S NO SCALE 3" HIGH CENTERED COLOR STANDARD, MIN INDIVIDUAL VINYL ABOVE ENTRY DOOR; AND TEXT TO MATCH BUILDING CMRONFSH LOCATION LETTERS, MOUNTED ON INTERIOR FACING EXTERIOR, SEE PLAN AND SIZE FOR LOCATION WITH FIR THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED DOM SIGN REQUIREMENTS: NOT AN EXIT, PER 2012 IBC SECTION 1011.3 1. READILY VISIBLE AND DURABLE SIGN SHALL BE PLACED EXIT OR ROOM WALL MOUNTED SIGNAGE !IIIIIIIIINIMMIMMINNYNAME SIGN, S E TO BE LOCATED ON 1. EACH GRADE -LEVEL EXTERIOR EXIT DOOR SHALL ON OR ADJACENT TO THE DOOR. DTL 2E jRIGHT FOR EXI SIGN GE EQ EQ LATCH SIDE OF DOOR CLEAR OF DOOR -SWING. 6 BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORD, "EXIT" �// 6" 2. HEIGHT OF LETTERS 1" MINIMUM HELVETICA FONT. WHITE OR BLACK LETTERS TO CONTRAST WITH STOREFRONT COLOR. CRITERIA / / / 2. GRADEELIEVEIOOERXTERIORLEXIT BDIRECTLY 4F A STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A � TACTILE EXIT SIGN WITH THE FOLLOWING WORDS q EXIT DOOR SIGNAGE j"T 0NPTPTaPE COLOR TO BE BLUE \ \ AS EXIT TAIRTDOWN" B. "EXIT RAMP DOWN" C. "EXIT STAIR UP BACKGROUND WITH WHITE LETTERS (fDi r D. "EXIT RAMP UP" I �+ ' �I PUSH TO EXIT SYMBOL SHALL BE WHITE ON A BLUE C- �I► 1/32" RAISED PICTOGRAM n y 3. EACH EXIT DOOR THAT LEADS DIRECTLY TO A 1 WITH 70% CONTRASTING 60" GRADE LEVEL C ' BACKGROUND SIM ROOM NAME O O BETWEEN BACKGROUND AND EXTERIOR EXIT BY MEANS OF AN SIGN REQUIREMENTS: TEXT. FINISH TO BE EXIT ENCLOSURE THAT DOES NOT U3 A STAIR RAMP, OR AN EXIT PASSAGEWAY SHALL BE SHALL 1. SIGN SHALL BE LOCATED 40"-48" AFF.g" SIGN REQUIREMENTS: EGGSHELL / ID IDENTIFIED BY A TACTILE SIGN WITH THE WORDS °' HEIGHT OF EXIT ROUTE" 2. THE EXIT DEVICE SHALL BE CLEARLY IDENTIFIED BY SIGN ON BAR. 1. UPPERCASE CHARACTERS RAISED 1/32" MEN WOMEN LETTERING 5// 8" HIGH BY 1/32" RAISED LEI IERING / / 4. EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN, SHALL BE IDENTIFIED BY A 3. LETTERS SHALL BE LOCATED ON A CONTRASTING 20 2. HEIGHT OF LETTERS 1" MINIMUM IN (UNLESS tyOTED/ TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE" BACKGROUND. HELVETICA FONT WITH WHITE LETTERS OTHERWISE)HELVETICA _ ON BLUE BACKGROUND. RESTROOM WALL PLAQUES FONT 5. EACH EXIT DOOR THROUGH A HORIZONTAL EXIT 4. COORDINATE AND INSTALL ANY SIGNAGE THAT C- xmmw CORRESPONDIN 0 SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN "TO INTERIOR MEW ACCOMPANIED THE EXIT DEVICE BAR. IF NONE WAS \ \ 3 3. TEXT VARIES, SEE PLANS FOR TEXT GRADE 2 BRAILLE WITH THE WORDS EXIT" POSITIONED DIRECTLY SUPPUED, ORDER AS SPECIFIED. AND LOCATIONS. INTERNATIONAL SYMBOL EXIT, EXIT ROUTE, ROOM NAME BELOW TEXT ENTRY DOOR SIGNAGE (VINYL SIGN) EXIT DEVICE SIGNAGE OF ACCESSIBILITY (1 SIGNAGE (PLASTIC SIGN) SIGN VIEW RESTROOM SIGNAGE (PLASTIC SIGN) SIGN VIEW 0 RESTROOM DOOR SIGNAGE ( TACTILE EXIT SIGNAGE CRITERIA V A2 DOCR SIG \AG 0 B_i 0 m �J FOR LOCATIONS OF SIGNAGE SEE PLANS lJ LJ 0 1/2"=l'-0" CODE SIGNAGE 1. ALL EXISTING CODE COMPLIANCE/STATUTORY SIGNAGE TO REMAIN. NO CHANGE AS PART OF SCOPE OF WORK. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2018 �, r !� • fnE._. C CITY OF TUKroliA City of Tukwila BUILDING DIVISION NOV 26 2018 PERMIT CENTER CALLISOF TKL CallisonRTKL, Inc. The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 Tel: 212.354.9240 Fax: 212.354.9253 CallisonRTKL Project No: 003-160285.00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817.938.5860 www.bowlero.com Consultant Henderson Engineers, Inc. 8345 Lenexa Drive Suite 300 Lenexa, KS 66214 Tel: 913.742.5000 www.hei-eng.com Issued for Permit Client/Owner/Project Address Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Project Address 100 Andover Park W #100, Tukwila, WA 98188 Issue Drawing Log 11/9/2018 ISSUED FOR PERMIT Seal Sheet Identification ACCESSIBILITY DETAILS RIRETAILINYCIBOWLER0104-PROJECTSITUKWILA, WA11.4 ARCHfTECTURE12-CADIA-CONTRACT DRAWINGSWEW SHEETS 1/13/2016 3:59:2 ©2016 CallisonRTKL Inc. DEMOLITION NOTES: DEMOLITION LEGEND DESCRIPTION • SCALE: 3/32"=1-0" 8' 16' 1. REFER TO GENERAL NOTES ON SHEET A-002 FOR ADDITIONAL INFORMATION. 2. ALL DOORS, WALLS, FIXTURES, ETC. SHOWN IN HEAVY DASHED ONES ARE TO BE REMOVED AND DISPOSED OF UNLESS OTHERWISE NOTED. 3. ANY DAMAGE THAT MAY OCCUR DURING DEMOLITION AND/OR CONSTRUCTION DUE TO THE CONTRACTOR'S FAULT SHALL BE THE CONTRACTOR'S RESPONSIBILITY AND MUST BE RESTORED TO ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE 4. NOTIFY THE ARCHITECT AT ONCE OF ANY UNFORESEEN HAZARD OF ANY KIND BEFORE DEMOLTTKON IS COMPLETE 5. NO ALTERATION TO THE LANDLORD'S STRUCTURAL MEMBERS ARE ALLOWED. EXCEPT AS SHOWN ON STRUCTURAL DRAWINGS AS APPROVED BY LANDLORD. 6. COORDINATE WITH THE LANDLORD OR HIS/HER REPRESENTATIVE PERTAINING TO ANY DEMOLITION REQUIREMENT AND PROVISION AS REQUIRED. 7. IMMEDIATELY UPON COMPLETION OF DEMOLITION, ALL CONDMONS AND DIMENSIONS ARE TO BE CHECKED FOR VARIANCES. REPORT ANY DISCREPANCIES IMMEDIATELY TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF WORK. 8. GC MUST INVESTIGATE THE SITE PRIOR TO SUBMISSION OF HIS/HER BID TO ANTICIPATE ANY DEVIATION WHICH MAY NOT BE SHOWN ON THIS PLAN OR ANY OTHER DRAWINGS IN THESE CONSTRUCTION DOCUMENTS. 9. NO COMBUSTIBLE MATERIALS ARE ALLOWED ABOVE THE FINISHED CEILING. MATERIALS ABOVE CBUNG SHALL BE PLENUM RATED WITH FIAMESPREAD INDEX OF 25 OR LESS. 10. CONSTRUCTION SITE IS TO BE SEALED TIGHTLY. CONSTRUCTION BARRICADES, IF REQUIRED SHALL BE PER THE OWNERS'S REQUIREMENTS. 11. REFER TO SCOPE OF NEW WORK IN ELECTRICAL DRAWINGS FOR ELECTRICAL FIXTURES LINES. ETC., ENCOUNTERED DURING DEMOLITION. ANY ABANDONED AND/OR NOT USED EQUIPMENT, FIXTURES, WIRING, ETC., SHALL BE REMOVED FROM THE JOB SITE. 12. REFER TO SCOPE OF NEW WORK IN MECHANICAL DRAWINGS FOR ANY EQUIPMENT, DUCTWORK REGISTERS, ETC., ENCOUNTERED DURING DEMOLITION. ANY ABANDONED AND/OR NOT USED EQUIPMENT, FIXTURES, DUCTWORK, REGISTERS, ETC., SHALL BE REMOVED FROM THE JOB SITE. 13. GC SHALL RELOCATE ANY EXISTING SERVICE ONES SUCH AS SPRINKLER MAIN, DOMESTIC WATER, SEWER LINE, GAS LINE ETC., IF REQUIRED TO ACCOMMODATE THE NEW WORK. ANY SUCH WORK MUST BE COORDINATED WITH THE LANDLORD. 14. ANY UNWED EXISTING CONDITIONS WHICH MAY CONFECT WITH THE PROPOSED NEW WORK AND MAY REQUIRE MODIFICATION, RELOCATION AND OR REMOVAL SHILL BE IDENDIF1E AND REPORTED TO THE ARCHITECT AT ONCE. 15. ANY MODIFICATION TO EXISTING SPRINKLER SYSTEM MUST BE APPROVED BY LOCAL FIRE DEPARTMENT OFFICER AND COORDINATED WITH LANDLORD'S REPRESENTATIVE. 16. GC TO IMMEDIATELY REPORT ANY EXPANSION OR CONSTRUCTION JOINTS LOCATED WITHIN TENANT SPACE TO ARCHITECT 17. GC TO IMMEDIATELY REPORT ANY STRUCTURAL, HAIRLINE, OR SUPERFICIAL CRACKING IN EXISTING CONCRETE SLAB TO ARCHITECT. 18. DEMOLITION WORK SHALL BE CONDUCTED IN ACCORDANCE WITH THE APPUCABLE SAFETY REQUIREMENTS OF THE LANDLORD. CITY AND STATE OF THE PROJECT, THE ASSOCIATED GENERAL CONTRACTOR'S MANUAL OF ACCIDENT PREVENTION IN CONSTRUCTION, LATEST EDITION, AND THE APPLICABLE REQUIREMENTS OF THE GOVERNING CODE, AND O.S.HA 19. EXISTING SERVICES THAT WILL BE DISRUPTED BY CONSTRUCTION WORK SHALL BE REROUTED AS NECESSARY TO PROVIDE TEMPORARY CONTINUATION OF SERVICE, PER CODE. 20. DEMOLITION WORK SHALL PROCEED IN SUCH A MANNER AS TO MINIMIZE THE SPREAD OF DUST AND FLYING PARTICLES MID TO PROVIDE SAFE WORKING CONDITIONS. 21. NOT USED. 22. GROUND MID FLOOR SURFACES ALONG ACCESS ROUTES AND IN RAMPS AND SPACES INCLUDING FLOORS, WALKWAYS, RAMPS, CORRIDORS, STAIRS, & CURB RAMPS SHALL BE STABLE, FIRM AND SLIP RESISTANT IN COMPLIANCE W/ SEC 4.5.1 OF THE AMERICANS WITH DISABILITIES ACT. 23. ASBESTOS NOTE IF ASBESTOS OR ANY OTHER TOXIC SUBSTANCE, OR RISKS TO EXPOSURE THEREOF IS DISCOVERED BY GC DURING DEMOLITION, GC SHALL NOTIFY THE CUENT IMMEDIATELY. CLIENT SHALL HAVE THE DUTY TO PROMPTLY RESOLVE. 24. ALL WORK TO BE WITHIN AREA OF CONTRACT ONLY, ALL ADJACENT AREAS ARE TO BE PROTECTED DURING ALL PHASES OF DEMOLITION & CONSTRUCTION. 25. SEE ENGINEERING DRAWINGS FOR DEMOLITION OF ASSOCIATED SYSTEMS. 26. WHERE MECHANICAL ELECTRICAL, OR PLUMBING DEVICES ARE REMOVED, ALL PIPING AND/OR CONDUITS THAT ARE ABANDONED SHALL BE CAPPED OFF BELOW THE FLOOR, INSIDE WALLS, OR ABOVE CEILINGS EXCEPT WHERE NOTED OTHERWISE ELECTRICAL AND MECHANICAL CONTRACTORS TO REMOVE ALL UNUSED WIRING TO PANEL BOXES. PATCH AND REPAIR FINISHED TO MATCH ADJACENT SURFACES. BLANK COVER PLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE UNLESS OTHERWISE NOTED. PROVIDE SUPPORT FOR EXISTING WIRING TO REMAIN. 27. GC RESPONSIBLE FOR CAPPING OF ALL ELECTRICAL, MECHANICAL, & PLUMBING AS REQUIRED. 28. CONSULT WITH OWNER BEFORE DEMOLITION TO DETERMINE IF THERE ARE ANY ITEMS TO BE SALVAGED AND REUSED, OR STORED. (SUBMIT UST OF ITEMS TO ARCHITECT). 29. GC SHAD. LOCATE ALL EXISTING ELECTRICAL PANELS, SWITCH GEAR, ETC. PROVIDE A DIAGRAMMATIC DRAWING TO ARCHITECT FOR REVIEW. INCLUDE SIZES OF PANELS AND AVAILABLE ELECTRICAL CIRCUITS ETC. IF PANELS REQUIRE RELOCATION, COORDINATE NEW LOCATION W/ ARCHTECT. 30. GC. SHALL PROVIDE PROTECTION BETWEEN ALL EXISTING AND NEW CONSTRUCTION AS NEEDED FOR A DUST PARTTION. SEAL TOP AND BOTTOM TO ASSURE NO DUST PENETRATES OCCUPIED SPACES. 31. ALL WAG DUCTWORK AND DIFFUSERS ARE TO REMAIN UNI FSS OTHERWISE NOTED. REFER TO ENGINEERING DRAWINGS FOR MORE INFORMATION. 32. GC SHALL FIELD VERIFY ANY STRUCTURAL WALLS THAT ARE AFFECTED BY THE DEMOLITION PLAN. CONTACT ARCHITECT W/ ANY ISSUES OR CONCERNS. DO NOT DEMOLISH ANY AREAS THAT ARE QUESTIONABLE. 33. GC SHALL COORDINATE DEMOLITION PLAN WITH ARCHITECTURAL PLAN. ONLY DEMO WALLS REQUIRED TO ACHIEVE NEW PLAN. 34. GC TO REPAIR ALL FLOOR, WALLS, CEILINGS TO REMAIN THAT WERE DAMAGED DURING DEMOLITION. 35. REMOVE AND REPLACE WALL BASE IN AREAS WHERE FLOORING IS REMOVED. 36. ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE DISCONNECTED AT SOURCE AND REMOVED. 37. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL NOTES AND SPECIFICATIONS. 38. SEE ENGINEERING DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS WHEN REFERRING TO HVAC, SPRINKLER, PLUMBING. 39. THE DEMOLITION CONTRACTOR IS RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE BUILDING RULES AND REGULATIONS BEFORE AND DURING THE COURSE OF CONSTRUCTION. SHOULD A CONFECT ARISE BETWEEN THE CONTRACT DOCUMENTS AND THE BUILDING RULES, THE CONTRACTOR IS TO NOTIFY ARCHITECT IMMEDIATELY. BUILDING RULES AND REGULATIONS SHALL GOVERN EXCEPT WHERE THEY ARE IN CONFLICT WITH APPLICABLE CODES AND ORDINANCES. 40. DEMOLITION CONTRACTOR TO COORDINATE ALL PHASES OF DEMOLTTON FOR PROJECT MID NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONFLICTING CONDITIONS WITH PROPOSED DRAWINGS WHICH WOULD INTERFERE WITH THE SATISFACTORY COMPLETION OF THE WORK, PRIOR TO THE START OF CONSTRUCTION. 41. DEMOLITION SHALL BE DONE IN NEAT WORKMANLIKE MANNER WITHIN THE MS INDICATED IN THE DRAWINGS AND IN ALL CASES TO THE EXTENT NEEDED TO PRODUCE THE INTENDED WORK. - GENERAL CONTRACTOR IS RESPONSIBLE FOR DEMOLITION AND REMOVAL OF ALL DEBRIS AND DISCARDED MATERIALS AND/OR EQUIPMENT AS INDICATED WITHIN THE SPACE - GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF MATERIALS PROM BUILDING PREMISES ON A DAILY BASIS. DO NOT MIX CONSTRUCTION DEBRIS WITH THAT OF BUILDING OCCUPANTS. - IMMEDIATELY CLEAN AND REMOVE ALL DEBRIS FROM AREAS AFTER DEMOLITION OPERATION AND BEFORE COMMENCEMENT OF THE NORMAL WORK DAY. 42. ALL MAJOR DEMOLITION AND NOISE CREATING WORK SHALL BE COORDINATED WITH OWNER FOR ALLOWABLE HOURS OF OPERATION. 43. GENERAL CONTRACTOR TO COORDINATE WITH THE OWNER/ ARCHITECT AS TO THE PROTECTION AND/OR STORAGE OF ANY ITEMS TO BE SAVED FROM DEMOLITION. 44. GENERAL CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING DENS TO REMAIN (I.E CORE PLUMBING FIXTURES, WINDOWS, CONVECTOR IF ANY, FIRE SAFETY DEVICES, FINISHED CEILING, LIGHT FIXTURES, FLOOR FINISHES. ETC.) THROUGHOUT THE COURSE OF DEMOLITION AND CONSTRUCTION. 45. GENERAL CONTRACTOR MUST PROVIDE ALL REQUIRED PROTECTION TO ALL SURROUNDING AREAS THAT ARE TO REMAIN THROUGHOUT COURSE OF DEMOLITION AND CONSTRUCTION. 46. GENERAL CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REPLACE MY DAMAGE IN THE TENANT SPACE AND SURROUNDING AREAS CAUSED BY DEMOLITION AND CONSTRUCTION IN AREA OF WORK." 47. ALL EXISTING PLUMBING, SHEET METAL DUCTS, FIRE AND LIFE SAFETY SYSTEM- ARE TO REMAIN UNLESS OTHERWISE NOTED IN ENGINEERING DOCUMENTS. 48. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY LOSSES INCURRED IN THE EVENT THAT THE LOSS OF ANY SERVICE PREVENTS THE TENANT FROM CONDUCTING BUSINESS. 49. ALL EXISTING BASE BUILDING FIRE ALARM DEVICES SHALL REMAIN UNDISTURBED & OPERABLE THROUGHOUT ALL PHASES OF CONSTRUCTION. REFER TO ENGINEER'S DRAWINGS FOR DEMOLITION SCOPE OF WORK FOR TENANT RELATED FIRE ALARM DEVICES. 50. ANY EXPOSED STEEL BEAMS AND OR COLUMNS SHALL BE RE -FIREPROOFED AS PER CODE REQUIREMENTS. 51. ALL COSTING LANDSCAPING AND GROUND COVER SHALL BE PROTECTED, AND IF DAMAGED, RESTORED TO THE SATISFACTION OF THE OWNER. 52. GC SHALL PROVIDE ANY BARRICADES, SUPPORTS, RULINGS, ETC. AS REQUIRED BY 0.S.H.A AND TO PROVIDE SAFE WORKING CONDITIONS. 53. GC TO INCLUDE PATCHING OF ANY EXISTING WALLS WHERE OUTLETS/SWITCHES/RECEPTACLES ARE TO BE REMOVED. DO NOT USE BLANK PLATE. 54. REMOVE ANY EXISTING WALLCOVERING, WALLS FINISHES, WALL BASE, MISCELLANEOUS UNUSED WALL OBJECTS FOR NEW SCHEDULED WALL FINISHES, TIP. WITHIN AREA OF WORK. COORDINATE WITH FINISH PLAN AND ELEVATIONS. 55. GC RESPONSIBLE FOR REMOVAL OF ALL UNUSED EXISTING FURNITURE COORDINATE WITH OWNER ITEMS TO BE DISCARDED/MAY ITEMS TO BE SALVAGED AND REUSED. REFER TO PROPOSED FURNITURE LAYOUT ON FURNITURE PLAN. EXISTING CONSTRUCTION TO REMAIN EXISTING PARTITION AND/OR GLASS PARTITION TO BE DEMOLISHED AND REMOVED AS INDICATED, COORDINATE AS REQUIRED. T = EXISTING DOOR/FRAME AND HARDWARE TO BE DEMOLISHED AND REMOVED AS REQUIRED. R EXISTING DEVICE TO BE REMOVED. KEY NOTE AREA NOT IN CONTRACT ADJACENT TENANT. N.I.C. KEY NOTES OALL WORK TO BE IN AREA OF CONTRACT ONLY. ALL ADJACENT AREAS TO BE PROTECTED DURING ALL PHASES OF CONSTRUCTION. O 16 18 24 28 66 67 GC TO DEMOLISH EXISTING INDICATED STAIRS AND RAILING. PROTECT EXISTING MASKING WALLS DURING DEMOU11ON/CONSTRUCTION. NO WORK TO EXISTING BOWLING LANES, APPROACH, PINSLIILRS, EQUIPMENT, UNO. PROTECT DURING COURSE OF DEMOLITION/CONSTRUCTION. EXISTING BON AREAS TO REMAIN U.O.N. GC TO DEMOLISH EXISTING MISCELLANEOUS WALL OBJECTS. GC TO REMOVE EXISTING SIGNAGE SALVAGE AND RETURN TO OWNER. GC TO DEMOLISH EXISTING INDICATED WALLS TO PLACE NEW DOOR. COORDINATE WITH A-100 "CONSTRUCTION PLAN". REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2018 City of Tukwila BUILDING DIVISION RECERVED CITY OF i UKW1LA NOV 26 2018 PERII IT CENTER CALLISORTKL CallisonRTKL, Inc. The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 Tel: 212.354.9240 Fax. 212.354.9253 CaIIisonRTKL Project No: 003-160285.00 Owner Bowlero 222 W 44th St New York, NY 10036 Tel 817.938.5860 www bowlero.com Consultant Henderson Engineers, Inc. 8345 Lenexa Drive Suite 300 Lenexa, KS 66214 Tel: 913.742.5000 www.hei-eng.com 0 CO Client/Owner/Project Address ssued for Permit Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Project Address 100 Andover Park W#100, Tukwila, WA 98188 Issue Drawing Log 111912017 ISSUED FOR PERMIT Seal Sheet Identification DEMOLITION PLAN P:IRETMLINYCIBOWLER0104-PROJECTSITUKWILA, WA11.4 ARCHITECTUREI2-CAD1A•CONTRACT DRAWINGSINEW SHEETS 1/13/2016 3:59 29 PM © 2016 CalhsonRTKL Inc. A-010 CONSTRUCTION PLAN NOTES : CONSTRUCTION PLAN NOTES : CONSTRUCTION LEGEND • SCALE. 3/32"=1'-O" 0 4' 8' 16' THE PARTITION -TYPE DESIGNATION OR WALL -TYPE DESIGNATION IS A THREE -UNIT CODE THAT INDICATES THE CONFIGURATION, CONSTRUCTION AND INSULATION OF THE PARTITION AS FOLLOWS INSULATION (PER THIS DETAIL, BELOW) CONSTRUCTION OF PARTITION/WALL VERTICAL CONFIGURATION OF PARTITION/WALL PARTITION/WALL SYMBOLOGY a T INSULATION DESIGNATION NO INSULATION BATT ACOUSTICAL INSULATION BATT THERMAL INSULATION NOTES 1. SEE SPECIFICATION FOR STUD SPACING AND GAGE 2 WHERE FIRE AND/OR SOUND RATINGS ARE INDICATED, THE GYPSUM BOARD REQUIRED SHALL BE CONTINUOUS BEHIND ABUTTING NONRATED PARTITIONS SO THAT FIRE AND/OR ACOUSTIC PERFORMANCE IS NOT COMPROMISED. TOP TRACK FASTENED TO B 0 DECK PUB SIDES PROADE BMSH WIERWS TO 6' RNISHED BOTTOM TRACK FASTENED TO FLOOR SLAB B NON -FIRE RATED PARTITION WITH FINISH MATERIALS ON BOTH SIDES DARTITION/WALL CONFIGURATION 1 J METAL STUDS FINISH AS SCHEDULED INSULATION IF NOTED 5/8" GYPSUM BOARD 3 5/8" METAL STUDS 1. REFER TO GENERAL CONSTRUCTION NOTES ON SHEET A-002 AND ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 2. G.C. IS RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING CONSTRUCTION TO REMAIN AND THE REPAIR OR REPLACEMENT OF ANY DAMAGE TO THAT OCCURS TO SUCH TEEMS. 3. G.C. TO MAINTAIN FIRE RESISTANCE RATING FOR ALL TENANT DEMISING WALLS. G.C.TO PATCH AND REPAIR ALL FIRE STOPPING AT PENETRATIONS AS REQUIRED. ALL FIRE PROOFING OF EXISTING STRUCTURAL STEEL COLUMNS, MEMBERS AND DECKING WITHIN LEASED SPACE TO REMAIN INTACT. G.C. TO REPAIR ANY DAMAGE TO EXISTING FIREPROOFING CAUSED DURING DEMOLITION OR CONSTRUCTION. 4. IN CASE OF DISCREPANCY BETWEEN THE ARCHITECT'S AND/OR ENGINEER'S DRAWINGS, THE MORE STRINGENT, HIGHER QUANTITY OR HIGHER QUALITY SHALL PREVAIL. G.C. IS TO INFORM ARCHITECT OF ANY SUCH DISCREPANCY PRIOR TO BID. 5. G.C. TO COORDINATE WITH LANDLORD FOR ANY WORK REQUIRED AT ROOF PENETRATIONS AND CONNECTION TO FIRE ALARM AND SPRINKLER SYSTEMS. 6. G.C. TO PROVIDE PARTITION LAYOUT FOR ARCHITECT AND OWNER APPROVAL PRIOR TO COMMENCEMENT OF CONSTRUCTION (AND DEMOLITION WHERE REQUIRED). G.C. TO START LAYOUT OF PARTITIONS WHERE ALIGNMENT WITH EXISTING MUST OCCUR. G.C. SHALL IMMEDIATELY REPORT ANY DISCREPANCIES OF A DIMENSIONAL OR MATERIAL NATURE WHICH IMPACTS INTENDED CONSTRUCTION OR SCHEDULE TO THE ARCHITECT AND OWNER. 7. IN AREAS WHERE OWNER'S FIXTURES REQUIRE AN EXACT FIT, G.C. TO VERIFY ALL DIMENSIONS WITH OWNER'S SHOP DRAWINGS AND REQUIREMENTS. 8. G.C. TO FURR OR LAMINATE ALL EXISTING AND NEW WALLS AS NECESSARY TO ACCOMMODATE ALL NEW CONSTRUCTION, MEP WORK, BLOCKING AND FINISH FOR A FLUSH SURFACE WHERE REQUIRED. 9. G.C. TO ENSURE EXISTING FLOOR SURFACE IS FLUSH, LEVEL, CLEAN AND READY TO ACCEPT NEW FINISH AS REQUIRED AT ALL FLOOR SURFACES. FLASH PATCH FLOOR SLAB AS REQUIRED, TYP. 10. G.C. IS REQUIRED TO COORDINATE CONSTRUCTION SCHEDULE WITH OWNER SCHEDULE PRIOR TO COMPLETION OF BID AND TO TRANSMIT WEEKLY UPDATES OF PROGRESS TO THE ARCHITECT DURING THE COURSE OF CONSTRUCTION. G.C. TO COORDINATE ALL CONSTRUCTION WITH LANDLORD SCHEDULE REQUIREMENTS. 11. G.C. IS RESPONSIBLE FOR SUBMITTING SHOP DRAWINGS, PERFORMANCE SPECIFICATIONS AND MATERIAL SAMPLES FOR ALL WORK IN A TIMELY MANNER TO THE ARCHITECT OR ENGINEER AS REQUIRED FOR APPROVAL 12. ALL INSTALLATION OF NEW DRYWALL SURFACES AND SKIMMING OF EXISTING SURFACES TO CONFORM TO A LEVEL 4 FINISH AT ALL FOH AREAS, UNLESS OTHERWISE NOTED. 13. DO NOT SCALE THE DRAWINGS. 14. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE WORK. 15. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 16. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UNLESS OTHERWISE INDICATED. 17. DOORS AND CASED OPENINGS INDICATED NEARBY WALL INTERSECTIONS, SHALL BE LOCATED SO THAT THE EDGE OF THE FINISH OPENING IS SIX INCHES FROM THE FACE OF THE NEARBY WALL UNLESS OTHERWISE INDICATED. ALL OTHER DOORS AND CASED OPENINGS SHALL BE CENTERED BETWEEN ADJACENT WALL INTERSECTIONS. 18. G.C. SHALL FURNISH & INSTALL SCHEDULED FIRE EXTINGUISHERS AS SHOWN ON EACH FLOOR PLAN. ALL FIRE EXTINGUISHERS TO BE SURFACE MOUNTED. COORDINATE EXACT LOCATION WITH ARCHITECT/DESIGNER PRIOR TO FINAL INSTALLATION. 19. WHERE DEMOLITION OCCURS ADJACENT TO EXISTING TO REMAIN, PATCH AND REPAIR ADJACENT CONDITIONS FOR A UNIFORM APPEARANCE. 20. COORDINATE FLOOR ELECTRICAL WITH EXISTING AND NEW FLOOR STRUCTURE. 21. MAINTAIN FIRE RESISTANCE RATING FOR ALL WALLS AND STRUCTURE. 22. WHERE EXISTING DOORS ARE TO REMAIN, BONDO/PAINT AS REQUIRED TO MAKE NEW. 23. ALL FLOOR PENETRATIONS ARE TO BE FIRE -STOPPED AS PER CURRENT CODE. 24. ALL EXISTING HOLES/CRACKS IN SLAB & THOSE RESULTING FROM THE CONSTRUCTION PROCESS SHALL BE FILLED / REPAIRED & THE SURFACE PATCHED SMOOTH & LEVEL WITH ADJACENT FLOOR SURFACE. 25. GC TO NOTIFY ARCHITECT/CLIENT PRIOR TO START OF CONSTRUCTION ANY LONG LEAD ITEMS. 26. ALL ITEMS ON PLAN SUPPLIED & INSTALLED BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 27. GC IS RESPONSIBLE FOR PROVIDING NEW FIRE SPRINKLER + FIRE ALARM SYSTEM IN ACCORDANCE WITH LOCAL FIRE DEPARTMENT STANDARDS FOR COMPLETE PROTECTION OF THE BUILDING OCCUPANTS. CONTRACTOR SHALL PAY ALL FEES, SECURE ALL PERMITS, AND HAVE ALL SHOP DRAWINGS APPROVED BY FIRE DEPARTMENT AND ARCHITECT PRIOR TO STARTING ANY BUILDING CONSTRUCTION. 28. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, ORDINANCES AND STANDARDS HAVING JURISDICTION, ANY QUESTIONS OR CONFLICTS CONCERNING COMPLIANCE WITH THESE SHOULD BE BROUGHT TO THE ATTENTIONS OF THE ARCHITECT. 29. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXISTING SITE CONDITIONS PRIOR TO SUBMITTING REQUESTS FOR INFORMATION, SHOP DRAWINGS, PRODUCT INFORMATION, ETC. 30. ALL MATERIALS FURNISHED SHALL BE NEW UNLESS OTHERWISE NOTED. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTIVE MATERIALS AND WORKMANSHIP FOR A MINIMUM PERIOD OF (1) YEAR OR AS SPECIFIED, WHICHEVER IS GREATER, AFTER THE DATE OF SUBSTANTIAL COMPLETION OR FINAL ACCEPTANCE OF THE WORK. 31. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED RECOMMENDATIONS FOR SERVICES INTENDED. 32. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, COLLAPSE AND MISALIGNMENT ACCORDING TO APPLICABLE CODES, STANDARDS, AND STANDARD CONSTRUCTION PRACTICES. 33. THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE, FIREPROOFING, AND FIRE RATING OF THE ENTIRE BUILDING. 34. GC TO FIRESTOP ALL PENETRATIONS AS REQUIRED TO MAINTAIN EXISTING RATING. 35. PROVIDE ACOUSTICAL SEALANT IN ALL PENETRATIONS IN ACOUSTICAL PARTITIONS. 36. UPON DISCOVERY OF HAZARDOUS MATERIALS ENCOUNTERED DURING CONSTRUCTION, NOTIFY THE ARCHITECT AND OWNER IMMEDIATELY FOR FURTHER INSTRUCTIONS FOR THE AFFECTED AREA. THE WORK AREA AFFECTED SHALL BE COMPLETELY SEALED OFF DURING ABATEMENT. 37. GYP. BOARD IN ALL TOILET ROOMS, JANITORS CLOSET, AND KITCHEN TO BE WATER RESISTANT TYPE. 38. GC. TO ASSURE THERE WILL BE A MINIMUM OF 44' EGRESS AISLE AROUND ALL EQUIPMENT, COUNTERS, GAMES, TABLES, ETC. PER CODE. 39. ALL CONTROLS FOR ALL SYSTEMS WITHIN THE BUILDING SHALL BE HANDICAPPED ACCESSIBLE. 40. REFER TO KITCHEN EQUIPMENT PLANS FOR LOCATIONS OF ALL FIRE RATED WOOD BLOCKING AS REQUIRED FOR ALL FOOD SERVICE EQUIPMENT IN KITCHEN, BAR, SNACK BAR, CONCOURSE BAR, TYP IF APPLICABLE. 41. GC TO FIELD VERIFY EXTENT OF EXISTING FIRE ALARM AND SPRINKLER SYSTEM. AS BUILT FIRE ALARM AND SPRINKLER SYSTEM SHOP DRAWINGS SHALL BE SUBMITTED TO THE APPLICABLE AGENCIES BY THE GC FOR APPROVAL THESE DRAWINGS SHALL BE MODIFIED TO REFLECT ALL ADDED OR RELOCATED HEADS, ETC. 42. ALL WALL MOUNTED OR SUSPENDED TELEVISIONS TO BE MOUNTED NO LOWER THAN 7'-6' MIN. COORDINATE WITH ARCHITECT EXACT MOUNTING HEIGHTS PRIOR TO INSTALLATION. ALL SUSPENSION BRACKETS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 43. PROVIDE, INSTALL, VERIFY, AND LOCATE EXACT NUMBER OF FIRE EXTINGUISHERS TO MEET LOCAL, STATE, AND FEDERAL STANDARDS. 44. BRACE ALL NEW INTERIOR WALLS W/ METALS STUDS, STAGGERED AT 4'-O'O.C. SECURE TO BOTTOM OF STEEL JOISTS IF NEEDED. 45. GC TO USE CEMENTTROUS BACKER BOARD AND SPACE STUDS AT 16'O.C. AT ALL PARTITIONS TO RECEIVE TILE OR STONE. 46. PROVIDE CONTROL JOINTS IN CEILINGS EXCEEDING 2500' SF AND IN WALLS AND FURRING RUNS GREATER THAN 30' LF, VERIFY EXACT LOCATIONS WITH ARCHITECT. 47. PROVIDE SLIP JOINT CONNECTIONS AT THE TOPS OF PARTITIONS WHICH INTERSECT THE STRUCTURE ABOVE, REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION. 48. EXPOSED PIPE, CONDUIT, DUCTS, ETC. SHALL BE CONCEALED IN NEW WALLS UNLESS OTHERWISE NOTED. WHEN INTENTIONALLY EXPOSED THEY MUST BE INSTALLED PLUMB AND SQUARE. 49. REFER TO ENGINEERING DRAWINGS FOR ACCESS PANEL LOCATIONS, TYPICAL 50. MECHANICAL HVAC CONTRACTOR IS RESPONSIBLE FOR INSTAWNG A FULLY OPERABLE HVAC SYSTEM IN ALL AREAS. COORDINATE ALL NEW WORK/EQUIPMENT NEEDS AND DUCT LAYOUTS WITH ENGINEERING DRAWINGS. TIE ANY NEW EQUIPMENT INTO EXISTING ELECTRICAL SERVICE. CONTRACTOR SHALL FIELD ASSESS THE CONDITION OF THE ENTIRE BUILDING HVAC SYSTEM. REWORK EXISTING DUCTWORK AND DIFFUSERS AND PROVIDE NEW SUPPLY AND RETURN AIR AS NEEDED TO INTEGRATE INTO NEW OVERALL PLAN LAYOUT. 51. VENDOR SUPPLIED GAMES SHALL BE INSTALLED WITH A MINIMUM AISLE WIDTH OF 44". AISLE WIDTH TO COMPLY WITH THE LOCAL FIRE CODES. 51. THE GENERAL CONTRACTOR (G.C.) IS RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE BUILDING RULES AND REGULATIONS BEFORE AND DURING THE COURSE OF CONSTRUCTION. SHOULD A CONFLICT ARISE BETWEEN THE CONTRACT DOCUMENTS AND THE BUILDING RULES, THE G.C. IS TO NOTIFY THE ARCHITECT IMMEDIATELY. BUILDING RULES AND REGULATIONS SHALL GOVERN EXCEPT WHERE THEY ARE IN CONFLICT WITH APPLICABLE CODES AND ORDINANCES. 52. CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL ITEMS TO REMAIN THROUGH THE ENTIRE COURSE OF DEMOLITION AND CONSTRUCTION (INCLUDING, BUT NOT LIMITED TO PARTITIONS, FINISHES, DOORS, FRAMES, HARDWARE AND ELECTRICAL CIRCUITRY). CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DAMAGE WHICH MIGHT OCCUR. 53. FOR ALL EXISTING CONSTRUCTION, GC SHALL MAKE ALL NECESSARY REMOVALS AND PATCH, LAMINATE, SKIM COAT OR RE-FURR AS NECESSARY ANY DAMAGED PARTITIONS TO REMAIN, IN ORDER TO PROVIDE A SMOOTH MONOLITHIC SURFACE FOR NEW FINISHES. CONTRACTOR SHALL PROVIDE PATCHING AS REQUIRED IN ORDER TO INSTALL NEW POWER/COMMUNICATION RECEPTACLES AND DEVICES. 54. ALL DAMAGED EXISTING FIRE RATED PARTITIONS THROUGHOUT TO BE REPAIRED TO MAINTAIN SAME FIRE RATING, ALL EXPOSED CORNERS TO BE FITTED WITH METAL CORNER BEADS. 55. WHERE DIMENSIONS ON PLAN CANNOT BE ACHIEVED, G.C. TO NOTIFY ARCHITECT PRIOR TO ANY FABRICATIONS. 56. BLOCKING - GENERAL CONTRACTOR AND THEIR SUB -CONTRACTORS TO FURNISH AND INSTALL ANY AND ALL NECESSARY FIRE RATED WOOD BLOCKING AT ALL PARTITIONS WHERE MILLWORK OCCURS. ALL BLOCKING TO BE FIRE RATED. 57. ALL WALLS, WHERE HOLLOW METAL DOOR FRAMES AND/OR WOOD FRAMES OCCUR, SHALL HAVE 2 STUDS BACK TO BACK ON EACH SIDE. 58. G.C. TO SCARPATCH ALL EXISTING TO NEW PARTITION JOINTS. 59. CONTRACTORS SHALL NOTIFY ARCHITECT UPON COMPLETION OF PARTITION LAYOUT CHALK LINES. NO STUDS OR TRACKS SHALL BE INSTALLED W/O APPROVAL FROM ARCHITECT. CONTRACTOR SHALL NOT SCALE OFF DRAWING OR DIMENSIONS. LAYOUT AND FINAL PLACEMENT OF ALL PARTITIONS TO BE APPROVED IN THE FIELD BY ARCHITECTS REPRESENTATIVE PRIOR TO COMMENCEMENT OF ANY WORK. 60. WHERE ALIGN SYMBOL IS INDICATED, G.C. TO ALIGN WALL WITH COLUMNS OR WALLS AS REQUIRED FOR 'CONTINUOUS' WALL AS SHOWN. 61. FLOORS: G.C. TO PATCH, REPAIR, LEVEL FLOOR SURFACES TO A SMOOTH AND LEVEL FINISH FOR THE PROPER INSTALLATION OF NEW FLOOR TREATMENT. 62. GENERAL CONTRACTOR TO SUBMIT SHOP DRAWINGS TO ARCHITECT'S OFFICE FOR REVIEW AND APPROVAL PRIOR TO THE FABRICATION OF ALL MILLWORK. 63. G.C. SHALL INSURE ACCESSIBILITY TO EXISTING ACCESS PANEL(S) ARE MAINTAINED. 64. G.C./DRYWALL CONTRACTOR TO COORDINATE REQUIRED PARTITION THICKNESS AT ALL PLUMBING, AND RECESSED FIRE EXTINGUISHER CABINET LOCATIONS. IF CONFUCT ARISES, NOTIFY ARCHITECT PRIOR TO CONSTRUCTION. 65. AT ALL LOCATIONS WHERE NEW ELECTRICAL AND VOICE/DATA OUTLETS OR ANY OTHER TYPE OF DEVICE IS TO BE INSTALLED AT EXISTING WALLS, BUILDING CORE WALLS, COLUMNS, PERIMETER WALLS AND/OR COLUMNS, THE GENERAL CONTRACTOR AND THEIR DRYWALL SUBCONTRACTOR ARE TO INCLUDE FURRING OUT EXISTING WALLS AND COLUMNS AS NEEDED IN ORDER TO ACCOMMODATE ANY AND ALL CONDUITS AND BACK BOXES U.O.N.. G.C. TO COORDINATE WITH ALL OTHER TRADES. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 66. PATCH ALL WALLS THAT WERE DAMAGED FROM DEMOLITION AS REQUIRED. GC. TO FURR/LAMINATE ALL EXISTING CONSTRUCTION AS REQUIRED TO PROVIDE A SMOOTH MONOLITHIC SURFACE. 67. BLOCKING - GENERAL CONTRACTOR AND THEIR SUB -CONTRACTORS TO FURNISH AND INSTALL ANY AND ALL NECESSARY FIRE RATED WOOD BLOCKING FOR ALL AV EQUIPMENT/ TV LOCATIONS. COORDINATE WITH AV INSTALLER AND POWER+COMMUNICATION PLAN. 68. GC. TO INCLUDE ALL COSTS TO PROVIDE FLASH PATCHING AND FEATHERING OF SLAB AS REQUIRED AT ALL FLOORING MATERIAL TRANSITIONS. 69. GC TO PROVIDE AND INSTALL ACCESSIBLE SIGNAGE IN ACCORDANCE WITH THE ADA STANDARDS FOR ACCESSIBLE DESIGN. 70. GC TO PROVIDE HANDICAPPED ACCESSIBILITY SYMBOLS AS REQUIRED BY CODE. ALL ACCESSIBILITY SYMBOLS SHALL BE MOUNTED ON THE WALLS ADJACENT TO THE LATCH SIDE OF THE COORDINATING DOOR. SUBMIT SAMPLES & DRAWINGS OF SIGNS TO ARCHITECT FOR APPROVAL 71. CONTRACTOR SHALL FURNISH AND INSTALL OCCUPANT LOAD SIGNS. SIGNS SHALL BE POSTED AT REQUIRED LOCATIONS/VERIFY WITH FIRE DEPARTMENT BEFORE COMPLETING JOB. SUBMIT SAMPLES & DRAWINGS OF SIGNS TO ARCHITECT FOR APPROVAL. 72. G.0 TO PATCH AND REPAIR ALL EXISTING PARTITIONS WHERE PARTITIONS WERE REMOVED. PROVIDE NEW CORNER BEAD AS REQUIRED. 73. G.C. TO PROVIDE FIRE TREATED WOOD BLOCKING IN PARTITION FOR NEW WALL MOUNTED TV. COORDINATE BLOCKING HEIGHTS AND LOCATIONS WITH OWNER. 74. G.C. TO PROVIDE FIRE TREATED WOOD BLOCKING IN PARTITION FOR WALL MOUNTED FURNITURE AND MILLWORK. COORDINATE MOUNTING HEIGHTS AND LOCATION WITH FURNITURE VENDOR. 75. ALL EXISTING COLUMNS SHOULD BE SMOOTH FINISH PATCH COLUMNS WHERE OLD DEVICES WERE REMOVED. DO NOT INSTALL BLANK COVER PLATES. 76. PATCH AND REPAIR WALLS WHERE EXISTING MILLWORK W, REMOVED. PREPARE WALLS FOR NEW FINISH. 77. PATCH AND REPAIR WALLS WHERE EXISTING TV, BLOCKIN POWER DATA OUTLETS HAVE BEEN REMOVED. PREPARE WALL FOR NEW FINISH. SYMBOL : DESCRIPTION : EXISTING CONSTRUCTION TO REMAIN NEW PARTITION TYPE, REFER TO CORRESPONDING PARTITION TYPE ON SHEET A-801 IN THIS SET OF DRAWINGS xxlxxIxx] WALL TYPE INDICATOR (DOOR) OPENING INDICATOR 11 TT ALIGNMENT SYMBOL U KEY NOTE SURFACE MOUNTED FIRE EXTINGUISHER F j (+E8PAdNSTALL BY GC EXISTING (DOOR) OPENING AREA NOT IN CONTRACT ADJACENT TENANT. N.I.C. PARTITION TYPE LEGEND CIOTOFP-01 PARTITION/WALL SYMBOLOGY THE PARTITION -TYPE DESIGNATION OR WALL -TYPE DESIGNATION IS A THREE - UNIT CODE THAT INDICATES THE CONFIGURATION, CONSTRUCTION AND INSULATION OF THE PARTITION AS FOLLOWS: INSULATION (PER THIS DETAIL,BELOW) CONSTRUCTION OF PARTITION/WALL VERTICAL CONFIGURATION OF PARTITION/WALL I 1-I NO INSULATION I ° I 2" FIBER SOUND-BATT INSULATION I I I t I BATI DERMAL NSUUIION INSULATION DESIGNATION KEY NOTES 1 ALL WORK TO BE WITHIN AREA OF CONTRACT ONLY. ALL ADJACENT AREAS ARE TO BE PROTECTED DURING ALL PHASES OF CONSTRUCTION. 12 PROTECT EXISTING BOWING/AV EQUIPMENT DURING CONSTRUCTION, COORDINATE WITH OWNER PRIOR TO COMMENCING WORK. 0 PROTECT EXISTING AV EQUIPMENT TO REMAIN, COORDINATE WITH OWNER. 50 INSTALL NEW GUARDRAIL/ HANDRAIL TO BLOCK DECORATIVE GARAGE DOOR OPENING, COORDINATE WITH PLAN DESIGN TO MATCH EXISTING. 4- GC TO PATCH AND REPAIR EXISTING WALLS TO REMAIN DUE TO DEMOLITION/CONSTRUCTION. 0 FILL IN OPENING W/NEW FLOOR TO CEILING STUD WALL AS SHOWN 60 INSTALL NEW PARTITION. CREATE AN OPENING AND INSTALL NEW DOOR/FRAME AS NOTED. 0 FILL IN OPENING W/NEW FLOOR TO COUNG STUD WALL AS SHOWN. 0 INSTALL NEW FLOOR TO CEILING STUD WALL AS SHOWN. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2018 City of Tukwila BUILDING DIVISION nECERIED CITY OF T € <. tLA NOV 2 6 2018 PERMIT CENTER CALLISOF TKL CallisonRTKL, Inc. The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 Tel: 212.354 9240 Fax: 212.354.9253 CallisonRTKL Project No: 003-160285 00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817 938 5860 www.bowlero.com Consultant Henderson Engineers, Inc. 8345 Lenexa Drive Suite 300 Lenexa, KS 66214 Tel: 913.742.5000 www.hei-eng corn ssued for Permit Client/Owner/Project Address Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Proiect Address 100 Andover Park W #100, Tukwila, WA 98188 Issue Drawing Log 11/9/2018 ISSUED FOR PERMIT Seal Sheet Identification CONSTRUCTION PLAN Dlg• Tunicl A-,00 JARTITION- PE LEGEND NO SCALE C1010FP-01 NO SCALE PARTITION NO SCALE C1010FP-20 PARETAILWYCIBOWLER0104PROJECTSITUKWILA, WA11.4 ARCHITECTUREI2-CADIA•CONTRACT DRAWINGSINEW SHEETS 1/13/2016 3:5929 PM © 2016 CaIlisonRTKL Inc NOTE: REFLECTED CEILING PLAN NOTES REFLECTED CEILING LEGEND GC TO RELAMP ALL EXISTING PENDANTS TO REMAIN WITH EDISON BULBS (SUPPLIED BY OWNER) 1. ALL LIGHTING FIXTURES AND CELNG EQUIPMENT TO BE LOCATED IN THE CENTER OF THE CEIUNG TILE, (U.O.N.) 2. ALL ELECTRICAL DEVICES, DATA, TO BE BLACK, COVER PLATES TO BE 'STAINLESS STEEL' (U.O.N.). PROVIDE SUBMITTAL FOR APPROVAL PRIOR TO INSTALL 3. CENTER ACOUSTICAL CEILING GRID WITHIN EACH ROOM (U.O.N.) 4. INSTALL ACOUSTICAL CEILING SYSTEMS AS PER DETAIL ON A-801. COORDINATE AS REQ'D. 5. ALL NEW SMOKE DETECTORS AND/OR ARE ALARM STROBES, AND ANY OTHER DEVICE SHALL BE FURNISHED AND INSTALLED AS REQUIRED AS PER LOCAL BUILDING CODE REFER TO ENGINEERING DRAWINGS. 6. G.C. TO PROVIDE CORRECT FIXTURE 'PROFILE' MOUNT DETAIL WITH THE EXIS1NG/NEW CEILING GRID. (TYP.) 7. ALL LIGHTING SPECIFICATIONS ARE AS INDICATED IN THE LIGHTING SCHEDULE COORDINATE ALL COMPONENTS AS REQUIRED TO ENSURE PROPER INSTALLATION AS PER MANE. SPECIFICATIONS. 8. REFER TO ENGINEERING DRAWINGS FOR EMERGENCY UGHT SPECIFICATIONS AND LOCAL LAW REQUIREMENTS. 9. ALL LIGHTING SHALL BE INSTALLED IN CONFORMANCE WITH ELECTRICAL CODES. 10. HVAC CONTRACTOR TO PROVIDE ARCHITECT W/ BALANCING REPORT & SUBMIT TO BUILDING MANAGEMENT. HVAC CONTRACTOR TO NOTIFY BUILDING CHIEF ENGINEER OF DATE & TIME OF BALANCING FOR WITNESS. 11. G.C./C.M. SHALL COORDINATE ALL TRADES AFFECTED BY HUNG CEILING CONSTRUCTION (HVAC, SPRINKLER, UGHTING, POWER, ETC). 12. FINAL LOCATION OF ALL THERMOSTATS AND FIRE ALARM STROBES TO BE APPROVED BY ARCHITECT. DO NOT LOCATE ANY DEVICE ON FEATURE WALLS OR BEHIND FURNITURE PANELS (U.O.N.). 13. G.C./C.M. SHALL COORDINATE ALL HEIGHTS BETWEEN LIGHT FIXTURES, DUCTWORK, SPRINKLER WORK ETC.. 14. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING SHOP DRAWINGS FOR SPECIFIED EQUIPMENT FOR APPROVAL TO ARCHITECT ON TIMELY EASES. SOME LIGHTING FIXTURES MAY REQUIRE LONGER LEAD DIE WHICH ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALLOWING SUFFICIENT TIME FOR ORDER PLACEMENT, SUBMITTAL REVIEW & ORDER RELEASE. 15. G.C./C.M. TO PROVIDE ALL NECESSARY TRANSFER OPENINGS ABOVE FINISHED CEILINGS THROUGHOUT THE SCOPE OF WORK. G.C./C.M. MUST COORDINATE WITH MEP ENGINEERS FOR APPROPRIATE SIZES, QUANTITY AND LOCATIONS PRIOR TO PROCEEDING. 16. ALL LIGHT FIXTURE TRIMS/COLORS TO BE CONFIRMED BY ARCHITECT (TYP.) NO EXCEPTIONS AND NO SUBSTIMONS. (U.O.N.) COORDINATE WITH ALL SPECIFICATIONS AND SUBMISSIONS AS REQ'D. 17. ALL AFFECTED FIRE PROOFING, STOPPING SHALL BE REPLACED. 18. ALL WORK TO BE WITHIN AREA OF CONTRACT ONLY. 19. GC TO PAINT ENTIRE CEILING WITHIN ROOM WHERE WORK HAS BEEN PREFORMED. 20. GC TO EXTEND ANY WALLS WHERE CEILING IS TO BE EXPOSED TO DECK. 21. GC TO PROVIDE EMERGENCY/NIGHT LIGHTING AS REQUIRED PER CODE, REFER TO ENGINEERING DRAWINGS FOR MORE INFORMATION. 22. GC TO COORDINATE ALL PENDANT/TRACK LIGHT FIXTURE MOUNTING HEIGHTS AS REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION. 23. GC TO VERIFY ALL LIGHT FIXTURE VOLTAGES PRIOR TO PURCHASE. 24. REFER TO ENGINEERING DRAWINGS FOR CIRCUITING/DIMMING. 25. All EXPOSED STRUCTURE, MECHANICAL, ELECTRICAL, FIRE PROTECTION, CONDUIT, CLEAN UP LIGHTS, ETC. TO BE PAINTED, SEE FNISH PLAN FOR COLOR. 26. All SUSPENDED ACOUSTICAL PANEL CEILINGS NEED TO BE TURNED DOWN FOR FASCIA, ABOVE ALL COOLER & FREEZER UNIT WALLS. FIELD VERIFY HEIGHT OF WALLS, TIP. 27. ALL GYPSUM BOARD TO EXTEND 6' ABOVE CEILING AT ALL CEILING SYSTEMS (UNLESS OTHERWISE NOTED). 28. GC. SHALL PROVIDE AN ADEQUATE NUMBER OF EMERGENCY LIGHTS AND EXIT LIGHTS TO MEET LOCAL INSPECTOR'S REQUIREMENTS (GC. SHALL CONFIRM EXACT NUMBER BEFORE SUBMITTING BID). 29. GC SHALL INSTALL ALL UNISTRUTS AS REQUIRED: - FOR ALL MISCELLANEOUS CEILING MOUNTED EQUIPMENT. - AS REQUIRED TO SECURE/BRACE/BRIDGE LIGHT FIXTURES TO EXISTING CEILING DECK/STRUCTURE 30. CEILING HEIGHTS SHALL BE NO LOWER THAN 7'-6' (COORDINATE ALL POTENTIAL CONFLICTS WITH ARCHITECT). 31. CONTRACTOR TO COORDINATE ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEIUNG SUPSENSION SYSTEMS, ETC. TO INSURE THE CEILING HEIGHTS INDICATED ARE MAINTAINED. 32. ALL NEW PIPING/CONDUITS TO BE RUN ABOVE CBUNGS IN AREAS WITH CEILINGS AND SHALL BE RUN AS HIGH AS POSSIBLE IN AREAS WITHOUT CEILINGS, UNLESS OTHERWISE NOTED. 33, GC TO REPLACE ANY DAMAGED,STAJNED, OR MISSING CEILING TILES TO REMAIN, TIP. THROUGHOUT CENTER. 34. GC TO CONFIRM WHETHER GRID LAYOUT WILL ALLOW LIGHTS TO BE LAID OUT AS SHOWN IN EXISTING AREAS (COORDINATE WITH ARCHITECT). 35. LIGHT FIXTURES LOCATED OVER UNCOVERED FOOD AND/OR EQUIPMENT MUST HAVE SHATTERPROOF BULBS AND/OR COVERS. 36. THE AUDIOVISUAL SUBCONTRACTOR IS RESPONSIBLE FOR DESIGNATING SPEAKER LOCATIONS THROUGHOUT THE FACILITY. FOR PROPER INSTALLATION OF AUDIO EQUIPMENT, THE AUDIO SUBCONTRACTOR SHALL COORDINATE ANY PROVISIONS NECESSARY BY THE GC AND ALL APPLICABLE TRADES. THE GC SHALL CUT ALL REQUIRED OPENINGS IN ACOUSTICAL TILE/GYPSUM BOARD CBUNGS AS REQUIRED FOR THE AUDIO SUBCONTRACTOR (VERIFY IN FIELD WITH OWNER). 37. PROVIDE CEILING ACCESS PANELS IN ALL GYPSUM BOARD CEILINGS AS REQUIRED FOR ACCESS TO ANY BUILDING PIPING, VALVES, VAV BOXES, ETC. TYP. THROUGHOUT. 38. REPAIR FIRESTOPPING AS REQUIRED AT ALL EXPOSED STEEL DECKS/BEAMS AS REQUIRED TO MAINTAIN EXISTING RATING. 39. ALL HVAC DIFFUSERS, SPRINKLERS, ETC. TO BE CENILNEU IN CEILING TILES U.O.N. 40. SEE ENGINEERING DRAWINGS FOR QUANTITIES OF ALL CEILING DIFFUSERS, DUCTWORK LAYOUTS, ETC. 41. SEE ENGINEERING DRAWINGS FOR ALL LIGHT FIXTURE CIRCUITING, SWITCHING AND RELATED WORK. 42. HVAC SUBCONTRACTOR TO SUBMIT A LAYOUT SHOP DRAWING INDICATING ALL DIFFUSER LOCATIONS AND DUCTWORK LAYOUTS TO ARCHITECT'S OFFICE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION OF ANY WORK AND AFTER ALL PARTITION TRACK LAYOUT HAS BEEN APPROVED BY ARCHITECT IN FIEID. 43. G.C. WILL BE RESPONSIBLE FOR COORDINATING THE LIGHTING FIXTURES WITH ALL CEILING DUCTWORK. SPRINKLERS, CONDUITS, ETC. 44. FINAL LOCATION OF ALL STROBES & THERMOSTATS TO BE VERIFIED IN FIELD WITH ARCHITECT PRIOR TO START OF INSTALLATION. 45. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL NOTES AND INFORMATION INCLUDING LOCATIONS OF ALL DIMMERS, SWITCH GANGS AND CIRCUITRY. (NOTE ARCHITECTURAL DRAWINGS INDICATE THE LOCATION OF SWITCHES/DIMMERS ONLY, REFER TO ENGINEERING DRAWINGS FOR ACTUAL QUANTITY AND ADDITIONAL LOCATIONS. 46. REFER TO ENGINEERING DRAWINGS FOR ALL AIR TRANSFER GRILLS AND DUCTS ABOVE FINISHED CEILING. 47. EACH SUB -TRADE SHALL BE RESPONSIBLE FOR REVIEWING ENTIRE SET OF DRAWINGS AND NOTING HIS WORK AS APPLICABLE WORK INDICATED OR INFERRED ON THE DRAWINGS SHALL BE DEEMED UNDERSTOOD AND SHALL BE INCLUDED IN SUBCONTRACTOR'S COSTS. SAME SHALL APPLY TO GENERAL CONTRACTOR. 48. GENERAL CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS IN INTENT TO ACCOMPLISHING ALL WORK ON PLAN AND THE COORDINATION OF THIS PLAN WITH ENGINEERING DRAWINGS OR IT WILL BE DEEMED THAT ALL NECESSARY WORK AND COST ARE INCLUDED. 49. GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL THE APPROPRIATE LAMPS AS REQUIRED BY THE SPECIFIED LIGHT FIXTURES. 50. MULTIPLE SWITCH AND/OR DIMMER GANGS SHALL HAVE CUSTOM SINGLE PLATE FOR EACH ROW. 51. G.C. TO PROVIDE ALL NECESSARY BLOCKING/BRACING AS REQUIRED FOR THE INSTALLATION OF ALL CEILING HUNG ITEMS SHOWN ON ARCHITECTURAL, ENGINEERING, TELECOM., SECURITY, & A/V DRAWINGS. 52. PROVIDE NEW EXIT SIGNS AS NOTED. 53. CONTRACTOR SHALL PROVIDE APPROPRIATE -SIZE CUTOUT ABOVE THE CEILING WHERE THE GYPSUM BOARD PARTITIONS EXTEND TO THE SLAB ABOVE, AS REQUIRED FOR THE CIRCULATION OF RETURN AIR TO THE HVAC SYSTEM. 54. PROVIDE ACCESS DOORS/PANELS TO ALL CEILING HUNG A/C UNITS OR OTHER MECH. EQUIPMENT AS REQ'D. 55. LIGHT SWITCH AND DIMMER CIRCUITING AS INDICATED ON ARCHITECT'S PLANS IS FOR SWITCH LOCATION ONLY. CONTRACTOR IS TO VERIFY ALL LIGHT FIXTURE WATTAGE (MAX.) AND PROVIDE PROPER NUMBER OF SWITCHES AT THAT LOCATION TO SERVICE THE INDICATED UGHT FIXTURES. 56. CEILING HEIGHT SHALL BE MAINTAINED THROUGHOUT AS INDICATED. G.C. SHALL NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO THE START OF CONSTRUCTION. 57. THE ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE PROPER LOCATIONS OF LIGHTING FIXTURES. DO NOT SCALE ELECTRICAL DRAWINGS FOR EXACT LOCATION OF THE LIGHTING FIXTURES. VERIFY DIMENSIONS IN FIELD. 58. G.C. TO INSTALL EACH FIXTURE PROPERLY, PLUMB, TRUE, IN ALIGNMENT AND FREE OF DISTORTION. G.C. TO PROVIDE HANGER RODS, MOUNTING BRACKETS, MISCELLANEOUS FRAMING SUPPORTING OR ATTACHING DEVICES, FRAMES AND OTHER COMPONENTS OR EQUIPMENT AS REQUIRED FOR A COMPLETE INSTALLATION, AND AS REQUIRED TO PROPERLY SUPPORT IMPOSED LOADS INCLUDING FIXTURE WEIGHT. SECURE LIGHTING FIXTURES TO SUPPORTS. SUPPORT ALL LIGHTING FIXTURES INDEPENDENTLY OF DUCT WORK, PIPING, CEILING SUPPORTS OR OTHER ITEMS OCCURING WITHIN THE CEILING. 59. MECHANICAL ELECTRICAL AND STRUCTURAL SUB -CONTRACTORS ARE RESPONSIBLE FOR ALL CONTROLLED INSPECTION AS IT RELATES TO THE WORK HERE IN AND BLDG. DEPT FORMS. 60. ALL CEILING TILE AND GRID IN ROOMS TO BE EQUAL -EQUAL IN ALL DIRECTIONS AS INDICATED ON PLAN UNLESS OTHERWISE NOTED. ANY DISCREPANCIES WITH CEILING LAYOUT MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. 61. ACCESS PANELS - ALL ACCESS PANELS TO BE INSTALLED IN DRYWALL CEILINGS ARE TO BE THE FIBERGLASS HINGE -LESS TYPE AND BE INSTALLED IN ALL LOCATIONS WHERE ABOVE INFRASTRUCTURE ELEMENTS REQUIRE AN ACCESS PANEL TO MAINTAIN BUILDING SYSTEMS, INCLUDING BUT NOT LIMITED TO ANY EXISTING AND OR NEW AC UNITS, ALL VAV BOXES, ALL SLIDING DOORS, AREAS THAT REQUIRE ADJUSTMENTS, IN ADDITION TO ANY AND ALL LOCATIONS FOR ELECTRICAL, MECHANICAL, PLUMBING, FIRE ALARM, SECURITY THAT WOULD REQUIRE ADJUSTMENTS TO MAINTAIN THAT NEW AND/OR EXISTING EQUIPMENT. ALL ACCESS PANEL LOCATIONS IN GYP. BOARD CEILING TO BE CONFIRMED IN FIELD BY ARCHITECT/DESIGNER PRIOR TO INSTALLATION. 62. G.C. IS RESPONSIBLE FOR SUPPLYING ALL EMERGENCY AND NIGHT LIGHTS, SPEAKER STROBES, THERMOSTATS ETC., THROUGHOUT THE 'AREA OF WORK'. 63. CONTRACTOR SHALL CONFIRM ALL CEILING STARTING POINTS WITH THE ARCHITECT PRIOR TO INSTALLATION. ANY 'DUTCHMAN' OR CEILING TRANSITION PIECES SHOULD BE CONFIRMED BY THE ARCHITECT PRIOR TO INSTALLATION. 64. CONTRACTOR TO PROVIDE ALL NECESSARY BLOCKING/ BRACING ABOVE HUNG CEILING AS REQUIRED FOR INSTALLATION OF ALL LIGHT FIXTURES, WINDOW BLINDS, PROJECTION SCREENS, VIDEO CAMERAS, PROJECTOR LIGHTS ETC. 65. GC. TO PROVIDE EMERGENCY LIGHTING AS REQ'D BY CODE REFER TO ENGINEERING DRAWINGS FOR EMERGENCY LIGHTING. 66. AU. SPRINKLER HEADS, HVAC DIFFUSERS, AND LIGHTING FIXTURES IN GYP. BOARD CEILING TO BE CONFIRMED IN FIELD BY ARCHITECT/DESIGNER PRIOR TO INSTALLATION. 67. GC. TO REPLACE ALL MISSING SPRINKLER CAPS. 68. GC. TO PATCH AND REPAIR AS REQUIRED ALL EXISTING CEILING TO REMAIN + SURROUNDING AREA(S) THAT WAS AFFECTED DURING DEMOLITION / CONSTRUCTION. 69. ALL EXPOSED CONDUITS TO BE PAINTED TO MATCH CEILING AND TIGHT TO DECK, UON 70. PROVIDE NEW EXIT SIGNS PER RCP LAYOUT, REMOVE ANY EXISTING EXIT SIGNS THAT ARE NOT USED/IRRELEVANT. 71. ALL NEW LIGHT SWITCHES TO COMPLY WITH ENERGY CODE GC TO REFER TO MEP DRAWINGS FOR SPECIFICATIONS ON SWITCHES. GC TO INSTALL LIGHT SWITCHES AS PER ARCHITECTURAL DRAWINGS. ARCHITECTURAL DRAWINGS INDICATE LOCATIONS ONLY, REFER TO ELECTRICAL DRAWINGS FOR CIRCUITING AND QUANTITY. 72. PAINT ALL EXPOSED CEILINGS, STRUCTURE, DUCTWORK, PIPING, CONDUITS, ETC. SCRAPE CEILING PRIOR TO PAINTING. 73. PROVIDE BLOCKING/SUPPORT/SEISMIC BRACING AS REQUIRED FOR ALL CEILING SUSPENDED+MOUNTED OBJECTS, AS REQUIRED FOR SUPPORT AND TO COMPLY WITH LOCAL CODE, TYP. 74. PAINT ALL NEW AND EXISTING DIFFUSERS TO MATCH CEILING. 75. CCTV CAMERAS AND CABLING BY OWNER'S VENDOR (SHOWN FOR REFERENCE) N PR SYMBOL DESCRIPTION (CI M15 ) (CI EX-PT2) STANDARD 2X4 CEILING TILE & GRID MFR: ARMSTRONG TILE MODEL: DUNE SQUARE LAY -IN 1851 2X4 GRID MODEL: MATCH EXISTING PRELUDE GRID NOTES: PAINT GRID AND TILE PI2 EXISTING STANDARD 2X4 CEILING TILE & GRID PAINTED MFR: SHERWIN WILL AMS COLOR: SW7076 CYBERSPACE FINISH: SATIN FINISH Zit (CI M37 ) TIN 2X2 CEILING TILE & GRID MFR: DECORATIVCE UNGTILES.NET TILE MODEL UNION SQUARE DROP IN 2X2 GRID MODEL: MATCH EXISTING - GRID TO BE PAINTED TO MATCH TILE. NOTES: GC TO CLEAR COAT VISIBLE FACE OF CEILING TILE TO PREVENT OXIDATION/CORROSION. (CI GWB ) EXISTING GYPSUM BOARD CEILING PATCH AND REPAIR AS REQUIRED CEILING GENERAL PANT: MAY: SHERWIN WILLIAMS COLOR: SW7076 CYBERSPACE FINISH: SATIN FINISH NOTE: ALL PANTED CEILINGS TO BE PAINTED WITH WATERBORNE ACRYLIC DRYFALL PAINT LETTER DESIGNATION & SYMBOLS INVAC RETURN. SEE ENGINEER'S DWGS. FOR MORE INFO. HVAC SUPPLY. SEE ENGINEER'S DWGS. FOR MORE INFO. KEY NOTE EX EXISTING TO REMAIN EXR EXISTING TO BE RELOCATED NEW PROJECTOR - EXISTING TO REMAIN CHANGE OF CEILING HEIGHT AND/OR MATERIAL AS SCHEDULED EXIT SIGNS - EXISTING TO REMAIN STROBE LIGHT - EXISTING TO REMAIN LIGHT SWITCH LOCATION SPRINKLER HEADS - REFER TO MEP DRAWINGS ® SECURITY CAMERA eel EMERGENCY BATTERY BACK MFG, EMERGI-LITE JC SERIES OR EQUAL (XX'-XX AFT) CEILING HEIGHT (CI ACT ) SP CEILING - MATERIAL NEW CEILING SPEAKER - REFER TO POWER & COMMUNICATIONS PLAN LIGHT FIXTURES L9.1 MANUF/SERIES: STONCO/PHIUPS CAT 1: VP11GC VGAIOO L21.1 LAMPS: 60 WATTS VINTAGE EDISON BULB; DIMMABLE MMNF/SERIES: CAT f: LAMP: NOTE KICHLER NO. 4-075-1-28-T5-BLACK (ICr128D) FINISH TO BE SEMI -GLOSS BLACK POWDERCOAT FP28/830/ECO [20868] ROSCO COLOR SLEEVES PER LAMP. ROSCO GEL COLOR: 12002 STORANO ORANGE, PROVIDE DIMMING BALLAST FOR FULL DIMMING FUNCTIONALITY. FIXTURE SUSPENDED FROM PAINTED BLACK THREADED RODS. 4U3 3 2 260 KEY NOTES SCALE: 3/32°=1'-0" 0 4' 8' 16' OELECTRICAL CEILING WORK TO BE IN ARCADE AREA ONLY. ALL ADJACENT 1 AREAS TO BE PROTECTED DURING ALL PHASES OF CONSTRUCTION. OPROVIDE JUNCTION BOX FOR CEILING MOUNTED LIT SIGNAGE GC TO COORDINATE SUPPORTS AND POWER REQUIREMENTS WITH SIGNAGE VENDOR. NEW HANGING L21.1 AND L9.1 LIGHT FIXTURE TO BE PLACED AT UNDERSIDE OF 25 DECK. HANGED TO ALIGN WITH B.O. BEAMS. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2018 City of Tukwila BUILDING DIVISION f'fECE!VE' CITY OF TUKWILA NOV 26 2018 PERMIT CENTER 11) g 4. o3�a CALLISOF TKL CallisonRTKL, Inc The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 Tel. 212.354 9240 Fax: 212.354 9253 CallisonRTKL Project No. 003-160285 00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817.938.5860 www bowlero.com Consultant Henderson Engineers, Inc 8345 Lenexa Drive Suite 300 Lenexa, KS 66214 Tel: 913.742.5000 www hei-eng corn Client/Owner/Project Address ssued for Permit Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Project Address 100 Andover Park W#100, Tukwila, WA 98188 Issue Drawing Log 11/ 912018 ISSUED FOR PERMIT Seal Sheet Identification REFLECTED CEILING PLAN P:VRETAILLNYC\BOWLERO104PROJECTS\TUKWILA, WA11.4 ARCHITECTURE\2-CADIA-CONTRACT DRAWINGSWEW SHEETS 1/1312016 3:5929 PM © 2016 CaT6sonRTKL Inc. A-200 POWER & DATA PLAN NOTES POWER & DATA LEGEND NOTE: REFER TO GENERAL POWER & COMMUNICATION NOTES ON SHEET A-002 AND ENGINEERING DRAWINGS FOR ADDITONAL INFORMATION. 1. ALL NEW ELECTRICAL OUTLETS 0 18" AFF TO COMPLY WITH DISABLE ACCESS CODES, BUILDING CODES, U.O.N. ALL ELEC. OUTLET RECEPTACLES TO MATCH BUILDING STANDARD. 2. ALL SEPARATE CIRCUIT ELECTRICAL OUTLETS SHALL HAVE ORANGE DEVICE. 3. ELECTRICAL CONTRACTOR SHALL PROVIDE POWER AND CONDUIT AS REQUIRED FOR SECURITY DEVICES. SECURITY DEVICES, WIRING, AND FINAL HOOKUP BY OTHERS. 4. ALL DEDICATED ELECTRICAL OUTLETS (FOR COMPUTER USE) SHALL MATCH BUILDING STANDARD. 5. NOT USED. 6. ALL CONDUIT SHALL RUN WITHIN WALL CAVITY AND NOT BE EXPOSED, INCLUDING AT EXISTING PARTITIONS AND COLUMNS. 7. NOT USED. 8. GC TO SUBMIT ALL PERMITS TO PROPERTY MANAGEMENT OFFICE PRIOR TO THE START OF WORK. 9. EXACT LOCATION FOR ALL POWER/TELE/DATA, AUDIO VISUAL DEVICES AND PULL BOXES ETC. TO BE VERIFIED IN FIELD W/ ARCHITECT, A/V & SECURITY CONSULTANT PRIOR TO INSTALLATION. 10. CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF ALL EQUIPMENT PRIOR TO INSTALLATION OF ALL OUTLETS AND CABLING. 11. ALL ELECTRICAL DEVICES TO BE COORDINATED WITH SECURITY CONSULTANT'S DRAWINGS AND COMMUNICATION CONSULTANT'S DRAWINGS. 12. THIS DRAWING SHALL BE USED IN CONJUNCTION WITH ENGINEERING DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS BEFORE PROCEEDING WITH WORK. 13. NOT USED. 14. G.C. TO COORDINATE ALL CORE DRILL LOCATIONS AND/OR FLOOR CHOPPING WITH ARCHITECT PRIOR TO COMMENCING WORK. ALL FLOOR BOX LOCATIONS ARE TO BE SPRAYED AND REVIEWED IN FIELD WITH ARCHITECT + OWNER PRIOR TO COMMENCING WORK. PATCH FLOOR AS REQUIRED. 15. ALL "P&C" OUTLETS TO BE LOCATED AS PER DIMENSIONED PLAN. OUTLET LOCATIONS ARE NOT TO BE SCALED FROM DRAWINGS. FINAL HEIGHTS OF ALL OUTLETS TO BE AS PER DIMENSIONED PLAN. OUTLETS INSTALLED WITHOUT DIMENSIONED "P&C" PLAN SHALL BE MOVED AS REQUIRED AT GENERAL CONTRACTOR'S OWN COST. 16. ALL THERMOSTAT & WALL MOUNTED SPEAKER /STROBES INDICATED ON ENGINEERING OR SHOP DRAWINGS MUST BE VERIFIED WITH ARCHITECT IN THE FIELD PRIOR TO INSTALLATION. 17. WHENEVER THERE IS A QUANTITY OR LOCATION CONFLICT BETWEEN THE ENGINEERING DRAWINGS AND ARCHITECTURAL PLANS, THE GREATER QUANTITY SHALL PREVAIL AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTAWNG ITEMS ACCORDING TO THE COMBINED DRAWINGS. ALL CIRCUITING SHALL BE AS INDICATED ON THE ENGINEERING DRAWINGS. SEE ENGINEERING DRAWINGS FOR ADDTTONAL ELECTRICAL INFORMATION REGARDING OUTLETS, CIRCUITING AND CLENT'S TEL/DATA REQUIREMENTS. 18. THE GENERAL CONTRACTOR SHALL PROVIDE A COMPLETE SET OF ARCHITECTURAL AND ENGINEERING DOCUMENTS TO THE ELECTRICAL SUBCONTRACTORS. THE ELECTRICAL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR ELECTRICAL ITEMS INDICATED ON ALL DRAWINGS, NOT JUST ENGINEERING PLANS. ARCHITECT SHALL BE NOTIFIED OF ANY CONFLICT OR INACCURACY PRIOR TO THE COMMENCEMENT OF WORK. 19. ALL NEW WORK SHALL BE INSTALLED CONCEALED, UNLESS OTHERWISE INDICATED OR REQUIRED. 20. CATALOGUE CUTS FOR ALL ELECTRICAL DEVICES AND PRE MANUFACTURED ITEMS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING. SUBSTITUTIONS WILL NOT BE ACCEPTED UNLESS PRIOR APPROVAL HAS BEEN GIVEN IN WRITING. 21. ANY OUTLET THAT PENETRATES RATED PARTITION IS TO BE FRE CAULKED PER CODE. 22. ALL ELECTRICAL DEVICES INSTALLED AT WET AREAS TO BE GROUND FAULT INTERRUPT TYPE DEVICES, SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION. 22. GC. TO VERIFY ALL OUTLET/ELECTRICAL DEVICE HEIGHTS FOR NS/MONITORS IN FIELD WITH ARCHITECT PRIOR TO COMMENCING WORK. PROVIDE FIRE RATED BLOCKING WITHIN PARTITION AS REQUIRED AT ALL TV LOCATIONS. 23. GC. TO COORDINATE ALL AV/IT/SECURITY WITH AV INSTALLER. AV INSTALLER TO PROVIDE INFORMATION REGARDING POWER/AV/IT REQUIREMENTS, CABLING, CONDUIT, AND RECEPTACLES. COORDINATE WITH AV INSTALLER ALL MOUNTING HEIGHTS AND RECEPTACLE HEIGHTS. 24. GC. TO CONFIRM LOCATION OF ALL THERMOSTATS AND SPEAKER STROBES WITH ARCHITECT PRIOR TO INSTALLATION. GC. WILL ASSUME COST TO MOVE ANY THERMOSTATS/STROBES AND ASSOCIATED WIRING THAT HAS NOT BEEN RENEWED WITH ARCHITECT IN FIELD THAT IS INSTALLED INCORRECTLY. 25. TERMINATIONS TO BE TYPE B, COLOR OF WIRING TO BE BLACK Ti?. 26. FACEPLATES/DEVICES COLORS TO VERIFIED WITH ARCHITECT. SEE ENGINEERING DRAWINGS. 27. ALL NEW DATA/LOW VOLTAGE CABLES TO BE CAT6 UNO. SEE ENG DWGS FOR MORE INFORMATION. 28. FOR ALL OUTLETS AT EXISTING PARTITIONS EITHER PARTIALLY DEMOUSH EXISTING WALL/REPAIR WALL, OR SNAKE THROUGH CEILING. NO SURFACE MOUNTED CONDUITS, TYP. 29. GC. TO PROVIDE TERMINATIONS FOR ALL TEL/DATA. 30. GC. TO PROVIDE ALL TERMINATING POINTS TO IT RACK. 31. AV VENDOR TO PROVIDE ALL TERMINATIONS FOR AV CABLING. 32. ALL POWER TO BE STANDARD 120V OUTLET AT EACH DROP UNLESS OTHERWISE NOTED. NOTE - REFERENCE ENGINEERING DRAWINGS FOR ADDITIONAL REQUIREMENTS FOR ALL SYMBOLS INDICATED BELOW. - GC TO PROVIDE FLOOR TRENCHING AS REQUIRED FOR ALL FLOOR MOUNTED RECEPTACLES/STUB UPS. LOCATE OUTLETS IN FIELD WITH ARCHITECT. PATCH AND REPAIR FLOOR SLAB AS REQUIRED FOR NEW SCHEDULED FLOOR FINISHES. - REFER TO ENG DRAWINGS FOR ALL FLOOR BOX/POKE-THRU SPECIFICATIONS. - GC TO REFER TO ELECTRICAL DRAWINGS FOR ALL VOLTAGE & AMP INFORMATION. SYMBOL DESCRIPTION WALL MOUNTED DUPLEX ELECTRICAL RECEPTACLE. FLOOR MOUNTED DUPLEX ELECTRICAL RECEPTACLE. FLOOR MOUNTED DUPLEX ELECTRICAL RECEPTACLE. FLOOR MOUNTED DUPLEX ELECTRICAL RECEPTACLE. CEILING MOUNTED DUPLEX ELECTRICAL RECEPTACLE, 15AMPS DEDICATED. CEILING MOUNTED DUPLEX ELECTRICAL RECEPTACLE, 20AMPS DEDICATED. Lx 374 N WALL MOUNTED COMBINATION VOICE DATA RECEPTACLE QUANTITY OF CABLE DROPS INDICATEDFOR REFERENCE ONLY. REFER TO ENG DWGS FOR MORE INFORMATION. WALL MOUNTED COMBINATION VOICE/DATA RECEPTACLE WITH CAT 6A CABLE PULL QUANTITY CABLE DROPS INDICATED FOR REFERENCE ONLY. REFER TO ENG DWGS FOR MORE INFORMATION. 20 AMP SIMPLEX. SEE ENG DWGS FOR MORE INFORMATION. WALL MOUNTED QUADPLEX ELECTRICAL RECEPTACLE. U JUNCTION BOX I®1 >olol FLOOR BOX - POWER, DATA, AV. COORDINATE WITH FURNITURE. AV AV RECEPTACLE MOUNTED PER PLAN & ELEVATIONS. FURNITURE MOUNTED POWER & DATA WALL MOUNTED HORN STROBE AT 80" A.F. WALL MOUNTED FIRE ALARM PULL BOX AT 48" A.F. WALL MOUNTED FIRE COMMUNICATION PHONE AT 48" A.F. THERMOSTAT SECURITY CAMERA LETTER DESIGNATION GFI EX. GROUND FAULT CIRCUIT INTERRUPT. SEE ENGINEERING DRAWINGS FOR MORE INFORMATION. EXISTING TO REMAIN. 42 AFF OUTLET HEIGHT ABOVE FLOOR C EXISTING CAPPED OUTLET TO BE MADE FUNCTIONAL AND GOOD. R EXISTING OUTLET(S) TO BE REMOVED OR RELOCATED TO A NEW OUTLET LOCATION AS REQUIRED. N NEW WALL MOUNTED OUTLET TO MATCH EXISTING. EQUIPMENT SCHEDULE <El 01 > CEILING MOUNTED PROJECTOR FURNISHED AND INSTALLED BY OWNER'S VENDOR <EI 02 > TV PROVIDED BY OWNER. GC TO PROVIDE POWER/DATA AS SHOWN. COORDINATE LOCATION W/ OWNER'S VENDOR. KEY NOTES @ALL WORK TO BE WITHIN AREA OF CONTRACT ONLY. ALL ADJACENT AREAS ARE TO BE PROTECTED DURING ALL PHASES OF CONSTRUCTION. 27 COORDINATE OUTLETS/RECEPTACLES WITH MILLWORK, RUN CONDUITS WITHIN MILLWORK CAVITY. 38 PROVIDE MILLWORK CONCEALED JUNCTION BOX FOR ILLUMINATED "BOWL" SIGNAGE. SEE SIGNAGE PACKAGE FOR ADDITIONAL INFORMATION. (-4.-; REUSE EXISTING J BOX FOR ILLUMINATED SIGNAGE. RELOCATE AS REQ'D; PATCH EXTERIOR AS REQ'D. 52 LOCATIONS /MOUNTING HEIGHT WITH ARCHITECLTIONS AT SHOE DESK. GC TO TORDINATE AND VERIFY EXISTING 75 OWNER'S SIGNAGE VENDOR TO INSTALL UT SIGNAGE. C TO PROVIDE POWER & BLOCKING AS REQUIRED. 78 TRENCH TO RUN CONDUIT FOR EVENTS DESK POWER AND DATA 0 PROVIDE JUNCTION BOX(ES) FOR HARDWIRED MILLWORK LIGHTING 0 NEW OWNER SUPPLIED ARCADE GAMES. LAYOUT TO BE CONFIRMED BY OWNER. SEPARATE PERMfTAND APPROVAL REQUIRED RECE!VEtj CITY OF TUKWILA NOV 26 2018 PERMIT CENTER CALLISORTKL CailisonRTKL, Inc. The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 Tel. 212 354.9240 Fax: 212.354.9253 CaIIisonRTKL Project No: 003-160285.00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817.938.5860 www bowlero corn Consultant Henderson Engineers, Inc 8345 Lenexa Drive Suite 300 Lenexa, KS 66214 Tel: 913.742.5000 www.hei-eng.com II MIN 0 co 0 co Client/Owner/Project Address Issued for Permit Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Project Address 100 Andover Park W #100, Tukwila, WA 98188 Issue Drawing Log 11/9/2018 ISSUED FOR PERMIT Seal ODD `SKI g OF ASHINGTON Sheet Identification POWER AND DATA PLAN SCALE. 3f32"=1' 0" C ' 0 4' 8' 16' \\ P:IRETAILWYCIBOWLER0104-PROJECTSITUKWILA, WA11.4 ARCHFFECTURE12-CADVALONTRACT DRAWINGSWEW SHEETS 1113/2016 3.59 29 PM ©2016 CallisonRTKL Inc. A-300 DOOR SCHEDULE DOOR FRAME REMARKS: DOOR TYPES DOOR HAND CALLISO RTKL HARDWARE FIRE DOOR# ROOM# NAME TYPE WIDTH HGT THK MATL FINISH HAND UNDERCUT HEAD JAMB MATL FINISH THRESHOLD SET RATING 103.1. 103 STORAGE ROOM 3'-D" - NM PT17 LA 5/B. HI J NM TO MATCH EXISTING 121 LOUNGE 2 TBD TNT - TOD TO MATCH TOD TBD TOD TBD TOD - TO MATCH - NEW DECORATIVE GARAGE DOOR TO MATCH EXISTING EXISTING EXISTING GRANGE DOORS. GC TO PROVIDE RUNG TO BLOCK DOOR OPENING. NEW RAILING TO MATCH COSTING. SEE VISUAUZATIDN PACKAGE FOR DETAILS. 121.1 121 STORAGE ROOM 3 7'-0' - HM PTI7 LW 5/B' HI UI HR TO MATCH EXISTING DOOR DETAILS CV DOOR LEAF jr 2" F 2" OLLOW METAL 'AME - DON qRY AU3 - I LVI' NEW RAILING DETAILS =AD PARTITION -TYPE VARIES HOLLOW METAL FRAME C1020-01 \ n1 \ DOOR LEAF - OLLOW METAL FRAM= - DOOM JAMS PARTITION -TYPE VARIES BEVEL AT LATCH EDGE HOLLOW METAL FRAME 6"=1'-0" C1020-04 SEE SCHEDULE OQDOOR TYPE 1 t SCALE NTS It TBD O MATCH EXISTING DI TO MATCH EXISTING DOORS IIIIII Illl�i Illl�i Illlii I pu IIIIII II�� "� ��� �. Illu• Ilu� 00 TBD 02 DOOR TYPE 2 IITS GLASINO LEFT HWD RICHE HWN LEER RAND REVERSE MOAT HAND REVERSE DDu&F DOOR PAR/um LEGEND ALM ALUMINUM PT PANT HM HOLLOW METAL WD SOLID WOOD GL GLASS - TEMPERED GENERAL HARDWARE FINISH: MATCH BUILDING STANDARD GENERAL NOTES: I. CONTRACTOR TO SUBMIT CUTS OF ALL HARDWARE TO ARCHITECT FOR APPROVAL PRIOR TO ORDER. 2. ALL LOCKS TO BE MASTER KEYED AND GRAND MASTER KEYED AS PER BUILDING AND TENANT SPECIFICATIONS. VERIFY AND COORDINATE AS REQUIRED. PROVIDE 3 MASTERS AND 3 GRAND MASTER KEYS. 3. ALL HARDWARE TO BE INSTALLED ACCORDING TO THE STANDARDS OF THE SPECIFIED MANUFACTURES USE. 4. ALL DOORS & ASSEMBLIES DESIGNATED TO BE FIRE RATED SHALL BE LABELED AS SUCH AS REQUIRED BY CODE. 5. THE FINISH HARDWARE SUPPUER SHALL EXAM THE DRAWINGS, SCHEDULE AND SPECIFICATIONS AND FURNISH PROPER HARDWARE FOR ALL OPENINGS WHETHER USTED OR NOT. COMPLETE SHOP DRAWINGS TO SE PROVIDED FOR REVIEW AND APPROVAL PRIOR TO PURCHASE 6. CONTRACTOR AT THE TIME OF THE BID TO VERIFY DELIVERY LEAD ONES FOR ALL DOORS/FRAMES AND HARDWARE AND INCLUDED COSTS FOR INSTALLATION WITHIN SCHEDULE, INCLUDING SUCH COSTS AS RE -WELDING, NON STANDARD BUCKS, OVERTIME FABRICATION ETC. 7. ALL DOORS AND HARDWARE 10 COMPLY WITH COBA/ANSI STANDARDS LATEST EDIHON. 8. ALL PARS OF DOORS TO BE RIGHT HAND ACTIVE UNLESS OTHER WISE NOTED. 9. DOOR HARDWARE IS INDICATED AS PER LEAF 10. ALL EXISTING DOORS/FRAMES AND HARDWARE PART OF BASE BUILDING ARE TO REMAIN AS IS UNLESS OTHERWISE NOTED. DOORS/FRAMES TO BE PAINTED AS NOTED ON FINISH PLAN. 11. ALL EXISTING DOORS/FRAMES AND HARDWARE PART OF BASE BUILDING ARE TO REMAIN AS IS UNLESS OTHERWISE NOTED. DOORS/FRAMES TO BE PAINTED AS NOTED ON FINISH PLAN. 12, ALL PAINTED DOORS TO BE SEMI GLOSS FINISH.. 13. FOR ALL EXISTING 000RS TO REMAIN: A GC TO BONDO & REPAIR AS REQUIRED TO 'MAKE NEW'. 8. GC TO SURVEY AND INCLUDE IN PRICE TO REPLACE ANY EXISTING DOORS TO REMAIN IN POOR OR DAMAGED CONDITION. 14. ALL NEW DOORS UNDERCUT 5/8" HARDWARE SCHEDULE HARDWARE SET G: STORAGE NOTE LOCKSET SCHLAGE OTHER D SERIES REMOVABLE CYLINDER "STORE ROOM FUNCTION" HINGES (3) STANLEY CB1900 4-1/2" z 4-1/2' FLUSH BOLT (2) IVES /265 MANUAL FLUSH BOLT SILENCERS (6) SR64 (GREY) FOR HM FLOOR STOP. (2) IVES #436 LOW PROFILE 1 -6' 111 LOUNGE EL >w C, UP 3 -0" LOUNGE ELEV NEW DECORATIVE GARAGE DOOR TO MATCH EXISTING GARAGE DOOR NEW RAILING TO MATCH EXISTING VF TO MATCH EXISTING EXISTING RAILING TO REMAIN AND PROTECT NEW RAILING A\D GARAGE DOOM 1/4"=1'-0" • • 13 t NEW RAILING TO MATCH EXISTING RAILING. EXISTING RAILING VIF. NEW DECORATIVE GARAGE DOOR TO MATCH EXISTING GARAGE DOOR 1'-1/2" 0 RAILING 1'-1/2" 0 INTERMEDIATE RAIL POST TO BE MOUNTED TO FLOOR TO MATCH EXISTING RAILING REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2CIO City of Tukwila BUILDING DIVISION NEW .AILING AND GMAGE DOO 1/2"=l'-0" RECEIVED CITY OF UKWILA NOV 262018 PERMIT CENTER CallisonRTKL, Inc. The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 Tel: 212.354.9240 Fax: 212.354.9253 CallisonRTKL Project No: 003-160285.00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817.938.5860 www.bowlero.com Consultant Henderson Engineers, Inc. 8345 Lenexa Drive Suite 300 Lenexa, KS 66214 Tel: 913.742.5000 www.hei-eng.com Issued for Permit Client/Owner/Project Address Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Project Address 100 Andover Park W #100, Tukwila, WA 98188 Issue Drawing Log 11/ 9/2018 ISSUED FOR PERMIT Seal Sheet Identification DOOR SCHEDULE AND DETAILS P:IRETAILWYCIBOWLER0104-PROJECTSITUI(WILA, WA11.4 ARCHITECTUREI2-CADIACONTRACT DRAWINGSIXREFS 111312016 3:5929 PM © 2016 CallisonRTKL Inc. CONSTRUCTION LEGEND SYMBOL : DESCRIPTION : <WA LUXON SELF CLEANING ACRYIJC COATING - SATIN CHERRY TOMATO SW6864 - 2 COATS CALLISO TKL CallisonRTKL, Inc. The Woolworth Building 233 Broadway, 16th Floor New York, NY 10279 AREA OF WORK GC TO REPLACE EXISTING EXTERIOR SIGNAGE WITH NEW 6-0" EXTERIOR UT BOWLERO SIGNAGE. PATCH WALL AND PAINT AS REQUIRED. GC TO COORDINATE BLOCKING AND ELECTRICAL AS REQUIRED FOR INSTALL EXISTING FACADE TO REMAIN, TYP V EXISTING EXTERIOR PAINT SCHEME TO REMAIN, TYP V -XT 1/4"=r-0" AREA OF WORK OR LEVATIO\ LI i. SOUT GC TO REPLACE EXISTING SIGNAGE WITH NEW 3'-0" EXTERIOR FACE-IT/BACK-UT BOWLERO CHANNEL LETTERS. (SIGNAGE BY OTHERS) EXISTING EXTERIOR COLUMNS TO BE PAINTED (2) COATS - LUXON SELF CLEANING ACRYLIC COATING - SATIN CHERRY TOMATO SW6864 EXISTING SIGNAGE BEAM TO REMAIN. EXISTING EXTERIOR SHOPFRONT TO REMAIN, TYP A AU3 3-1201S EXIS11NG AWING/ENTRY FACADE TO REMAIN, TYP EXISTING EXTERIOR COLUMNS TO BE PAINTED (2) COATS - LUXON SELF CLEANING ACRYUC COATING - SATIN CHERRY TOMATO SW6864 AREA OF WORK A NEW SIGNAGE. SEE B1/A-700. 110 GC TO REMOVE ALL EXISTING LOGOS FROM ALL EXTERIOR DOORS AND WINDOWS, TYP. 1 • EXISTING PATIO RAILIG TO REMAIN, TYP 1 6,411 At REVIEWED frOR CODE COMPLIANCE APPROVED DEC 17 2C18 City of Tukwila BUILDING DIVISION FIEC,9:11,mID CITY OF TUKWILA NOV 26 2018 PERMIT CENTER Tel: 212.354.9240 Fax: 212.354.9253 CallisonRTKL Project No: 003-160285.00 Owner Bowlero 222 W 44th St. New York, NY 10036 Tel: 817.938.5860 www.bowlero.com Consultant Henderson Engineers, Inc. 8345 Lenexa Drive Suite 300 Lenexa, KS 66214 Tel: 913.742.5000 www.hei-eng.com Issued for Permit Client/Owner/Project Address Bowlero Corporation Client Address 22 W44th Street, New York, NY 10036 Project Address 100 Andover Park W #100, Tukwila, WA 98188 Issue Drawing Log 11/912018 ISSUED FOR PERMIT Seal Sheet Identification EXTERIOR ELEVATIONS PARETAILINYOBOWLER0104-PROJECTSATUKWIIA WAV1.4 ARCHITECTURET-OAD1A-CONTRACT DRAWINGS1NEW SHEETS 1/1300163:59:29 PM © 2016 CallisonRTKL Inc.