Loading...
HomeMy WebLinkAboutPermit M17-0052 - PACIFIC STRAPPING - GAS-ELECTRIC ROOFTOP UNITPACIFIC STRAPPING INC 2922 S 112TH ST EXPIRED 10/31/2017 M17-0052 Parcel No: Address: c City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0423049148 2922 S 112TH ST Project Name: PACIFIC STRAPPING INC MECHANICAL PERMIT Permit Number: M17-0052 Issue Date: 5/4/2017 Permit Expires On: 10/31/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: NEVSCO LLC PO BOX 80, MERCER ISLAND, WA, 98040 KEITH RICE 1012 CENTRAL AVE S , KENT, WA, 98032 PERFORMANCE HEATING & A/C INC 1012 CENTRAL AVE S , KENT, WA, 98032 PERFOHA150RT Phone: (425) 251-0356 Phone: (425) 251-0356 Expiration Date: 4/30/2019 DESCRIPTION OF WORK: REPLACE FAILED 10 TON GAS/ELECTRIC ROOF TOP UNIT WITH NEW UNIT OF SAME SIZE Valuation of Work: $15,700.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $423.03 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 /Aianyl�i l AT1AAA ._ d11 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pprnif ana to the conditions attached to this permit. Signature: Print Name: �- rr-e-' Ve 4_5 Date: 5—Af 7 7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 2: ***MECHANICAL PERMIT CONDITIONS*** 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 7: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 8: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 9: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 10: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 11: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 13: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. c 0 PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWIZ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. VI l 7 cost Project No. Date Application Accepted: Date Application Expires: For o ce use onl MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 042304 9148 Site Address: 2922 S 112th St, Tukwila, WA 98168 Suite Number: Ilia Floor: n/a Tenant Name: Pacific Strapping Inc PROPERTY OWNER Name: Pacific Strapping Inc Address: 2922 S 112th St City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Keith Rice Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: Email: keith.r@pmghvac.com New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Mechanical Group Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: Contr Reg No.: PERFOHA15ORT Exp Date: 04/01/2017 Tukwila Business License No.: bus-0992987 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: REPLACE FAILED 10 TON GAS -ELECTRIC RTU UNIT WITH NEW UNIT OF SAME SIZE. 15,700 Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric ❑ Gas ® Other: Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfin 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW IXE,IC OR Ajd9i 1 RIZ Signature: Date: 04/17/2017 Print Name: Keith Rice Day Telephone: (425) 251-0356 Kent WA 98032 City State Zip Mailing Address: 1012 Central Ave S Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK `` ` $423 03 P° ern `•?. ,.;r. „- €,u�,- M17-0052 ° Address:. 2922 S-112TH'� y °E n 0423049148�� �d� sti $423 03 (i e , . ,, Credit Card Fee $12.32 Credit Card Fee R000.369.908.00.00 0.00 $12.32 MECHANICAL $394.91 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $282.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $78.98 TECHNOLOGY FEE $15.80 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11299 R000.322.900.04.00 0.00 $15.80 $423.03 Date Paid: Tuesday, April 18, 2017 Paid By: BARRETT ROBERTS Pay Method: CREDIT CARD 427287 City of Tukwila Department of Community Development 8/31/2017 KEITH RICE 1012 CENTRAL AVE S KENT, WA 98032 RE: Permit No. M17-0052 PACIFIC STRAPPING INC 2922 S 112 ST Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/31/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/31/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M17-0052 93ERMIT COORD COPY: o PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0052 DATE: 04/18/17 PROJECT NAME: PACIFIC STRAPPING INC SITE ADDRESS: 2922 S 112 ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: KWG 44-r r 1 Building Division Public Works ❑ AAA DM* Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) Planning Division Permit Coordinator DATE: 04/20/17 1 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: mvy DUE DATE: 05/18/17 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials: Home lispafiel Contact Search L&I SEARCH Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries A-Z Index Help My Uzi Workplace Rights Trades & Licensing PERFORMANCE HEATING & A/C INC Owner or tradesperson Principals MILLER, DANIEL E, PRESIDENT ERDAHL, DARRIN, VICE PRESIDENT GOWIN, RICHARD L, VICE PRESIDENT (End: 04/26/2011) GOWIN, CONSTANCE F, VICE PRESIDENT (End: 11/15/2007) Doing business as PERFORMANCE HEATING & A/C INC WA UBI No. 600 601 386 1012 Central Ave S KENT, WA 98032 425-251-0356 KING County Business type Corporation Governing persons DARRIN P ERDAHL DANIEL E MILLER; ILicense Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PERFOHA15ORT Effective — expiration 12/30/1985— 04/30/2019 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 748802C Active. Meets current requirements. $12,000.00 Received by L&I Effective date 11/27/2007 10/01/2007 Expiration date Until Canceled Insurance Charter Oak Fire Ins Co $1,000,000.00 Policy no. DT-CO-3J 659957-COF-1 Received by L&I Effective date 04/18/2017 04/28/2017 Expiration date Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 494.599-00 Doing business as PERFORMANCE HEATING & AIR COND Estimated workers reported Pending current quarter filing L&I account representative T1 / NICHOLE CAROW (360)902-5634 - Email: CANI235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 12/04/2015 Inspection no. 317938325 Location 3600 15th Ave W Seattle, WA 98119 No violations © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. SCOPE OF REPLACE A FAILED 10 TON PACKAGE UNIT W/ NEW pc COUNTY Pan" W1• 042304-9148 l PAR 2 OF TUKWILA SHORT PLAT L06-047 REC 20081030900001 SD SP DAF - POR GL 10 BEG AT NXN OF W OF HWY j1 & N MGN OF C OF S PIPE LN R/W BEING TPOB TH S 89-30-59 W 414.14 FT TH N 58-42-14 W 80.75 FT TH N 33-16-12 E 137 FT TH N 0-23-17 W 30 FT TH N 46-08-49 E 74.59 FT TH N 33-16-12 E 77 FT TO S MGN OF TRANS LN R/W TH S 57-20-50 E TO W MGN ST HWY j1 TH SWLY ALG WLY MGN SD HWY CODE NOTES PER 2015 IrS.E.C, MD 2015 at_ 1. HVAC SYSTEM CONTROLS TO COMPLY WITH W.S.E.C. SECTION C403.2.4.1 2. PROVIDE ECONOMIZER PER W.S.E.C. SECTION C403.3.1. 3. A 110V CONVENIENCE OUTLET SHALL BE WITHIN 25-0" OF OUTDOOR PER I.M.C. SECTION 306. 4. THERMOSTAT TO COMPLY WITH W.S.E.C. SECTION C403.2.4 5. SEAL AND INSULATE ALL NEW DUCTS PER W.S.E.C. SECTION C403.2.8 sly Ann ONERNIE IYALUAI121 ROOF AREA = 21,000 SF COVERAGE = 1,100 SF PERCENT COVERED = 5.2% S'1.12th St / AREA MAP 1/64" = 1'-0" eN <5 C AREA OF WORK a L KEY PLAN S •1'12th Stamm EXISTING SLEEPERS FOR UNIT RTU-1 NEW 28x20 INSULATED DUCT TO 26x46 DOWNSHAFT FIELD DETAIL EXACT PLENUM DIMENSIONS 3'-0"MIN. / ROOFTOP PARTIAL PLAN 1/4" = i -0" NEW 28x18 INSULATED DUCT CONNECTED TO EXISTING RETURN NEW LEVELF RTU-1 EXISTING ROOF SHED NEW 18x28 INSULATED DUCT CONNECTED TO DOWNSHAFT FIELD DETAIL EXACT PLENUM DIMENSIONS EXISTING 26x46 DN RECONNECT TO NEW DUCTWORK 3' MIN. I' EXISTING MOTOR SHED ..:IT 0 r. ; c ian:cal jpecincal L. ~Plumbing Vans Piping City of Tuic ila BUR.Crf4G DIVISION FILL a e,j( MI1-oog)1" BUILD NG O Ii ION ;r:nrP- (1 EAST ELEVATION 1/4" = 1'-0" ROOF PEAK SLEEPERS ROOF GROUND 22'-0" 19'-9" 18'-O" 14'-O" PACKAGE GAS -ELECTRIC ROOFTOP UNIT UNIT NO. MFG & MODEL NO NOM TONS IEER/ EER GAS HEAT MBH CFM OSA CFM ESP ELECTRICAL Vi/T LEIS NOTES INPUT OUTPUT VOLT/PH MOCP RTU-1 CARRIER 48TFD007 10 14.2/11.0 180 144 4000 800 0.5 460/3 30 1255 1,2,3,4,5,6,74 6 NOTES: 1. LEVEL UNIT, MOUNT PER STRUCTURAL DETAILS 2. REUSE EXISTING DISCONNECT 3. RECONNECT TO EXISTING GAS PIPING 4. TWO -STAGE COOLING 5. PROVIDE MODULATING ECONOMIZER W/LOW-LEAK DAMPERS 6. RECONNECT TO EXISTING THERMOSTAT 7. UNIT MEETS THE REQUIREMENTS OF C403.2.3(1)A . . o . 6,-Ai-01„w4-rC S ....o ke- 5 G, d ddos»k On. +f IA.P bt€±J t vv a I r r i eh,w,_ ptr / AA° & 06.2 ke VC - RECEIVED CITY OF TUKWILA APR 18 201/ PERMIT CENTER Dynamic Solutions for the Built Environment LU 0 REVISIONS LL U C- ROOFTOP PLANS CVO 6-dD JNIddV?LLS 3Idl3b'd 2922 S 112TH ST CO Co 0) J DATE: 4/16/2017 DRAWN: KR ENGR: KR APPVD: DL JOB NUMBER: 106306 tit I 1 o o st M-1 SHEET 1 OF 1