Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M18-0016 - BOEING #9-08 - WALL MOUNT A/C UNITS
BOEING #9-08 9725 E MARGINAL WAY S BLDG 9-008 FINALED 04/06/2020 M18-0016 0 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003400018 9725 E MARGINAL WAY S BLDG 9-050 Project Name: BOEING #9-50 Permit Number: M18-0016 Issue Date: 2/7/2018 Permit Expires On: 8/6/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-59 PROPERTY TAX DEPT, SEATTLE, WA, 98124 LAURI THODAY PO BOX 249 , AUBURN, WA, 98071 AUBURN MECHANICAL INC PO BOX 249 , AUBURN, WA, 98071 AUBURMI163BA II I Phone: (253) 255-4996 Phone: (253) 838-9780 Expiration Date: 9/12/2018 DESCRIPTION OF WORK: LABOR AND MATERIAL TO INSTALL 3 WALL MOUNT AIR CONDITIONING UNITS AND ASSOCIATED PIPING PER DRAWINGS DATED 8-15-17 Valuation of Work: $40,175.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $743.84 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: ` � / LiaLam[/ v Date: 0a22-7 7l(cF--- I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development ermit and agree to the conditions attached to this permit. LAA,ILCZ91/4,"- Signature: Print Name:\*b-U 1,1 cc Z g This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0705 0701 MECH EQUIP EFF MECHANICAL FINAL REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKWJA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi I aWA .gov Mechanical Permit No. VI `6� VO Project No. b Date Application Accepted: fiq ,( V Date Application Expires: "7-A -10 (For ice use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 0003400018 Site Address: 9725 East Marginal Way S Bldg 9-50 Suite Number: Floor: Tenant Name: Boeing Developmental Center New Tenant: ❑ Yes ..No PROPERTY OWNER Name: The Boeing Company Address: 9905 East Marginal Way S City: Seattle State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Lauri Thoday Address: 2623 West Valley Hwy N City: Auburn State: WA Zip: 98071 Phone: (253) 255-4996 Fax: (253) 833-1384 Email: laurithoday@auburnmechanical.com MECHANICAL CONTRACTOR INFORMATION Company Name: Auburn Mechanical Address: 2623 West Valley Hwy N City: Auburn State: WA Zip: 98071 Phone: (253) 838-9780 Fax: (253) 833-1384 Contr Reg No.: AUBURMI163BA Exp Date: 09/12/2018 Tukwila Business License No.: Q994349 Valuation of project (contractor's bid price): $ $40,175.00 Describe the scope of work in detail: Labor and material to install 3 wall mount air conditioning units and associated piping per drawings dated 8/15/20 Use. Residential: New 0 Replacement ❑ Commercial: New 0 Replacement 1c Fuel Type: Electric ❑ Gas n Other: Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > 100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <I0,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Bard AC Units 3 Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 *Daytim District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) A few sounds are exempt from the noise code, including: - Warning devices; Construction and property maintenance during the daytime hours (lam-1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the pennit center to comply with current fec schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OWNE UTHORIZED AGENT: Signature: Print Name: Lauri Thoday Mailing Address: 2623 West Valley Hwy N Date: 1/26/2018 Day Telephone: (253) 255-4996 Aubum WA 98071 City State Zip DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 00`79 M18-0016 Address: 9725 E MARGINAL WAY BLDG 9-050 -� Apn: 0003400018 MECHANICAL $572.18 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $539.03 TECHNOLOGY FEE $28.61 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13742 R000.322.900.04.00 0.00 $28.61 $600.79 Date Paid: Wednesday, February 07, 2018 Paid By: AUBURN MECHANICAL Pay Method: CHECK 12259 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY I PAID PermitTRAK 4305 M18-0016 Address: 9725 E MARGINAL WAY SBLDG"9-05! n'rv00034000 3 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R13582 0.00 $143.05 $143.05 Date Paid: Monday, January 29, 2018 Paid By: LAURI THODAY Pay Method: CHECK 4244 City of Tukwila Department of Community Development 3/5/2020 LAURI THODAY PO BOX 249 AUBURN, WA 98071 RE: Permit No. M18-0016 BOEING #9-08 9725 E MARGINALWAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/20/2020. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/20/2020, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0016 T,J1 Q City of Tukwila Allan Ekberg, Mayo! Department of Community Development - Jack Pace, Director June 3, 2019 Lauri Thoday PO Box 249 Auburn, WA 98071 RE: Request for Extension #1 Permit Number M18-0016 Dear Ms. Thoday, This letter is in response to your written request for an extension to Permit M18-0016. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through December 05, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, 4(-/Comex ,,t04) Kandace Nichols Permit Technician File: Permit No. M18-0016 Kandace Nichols From: Sent: To: Subject: Rachelle Ripley Wednesday, May 29, 2019 10:38 AM Kandace Nichols FW: Permit M18-0016 Good morning, Can you process an extension request on this? Thank you, Rachelle Ripley Permit Coordinator City of Tukwila 206-433-7165 Rachelle.Ripley(c�TukwilaWA.gov I http://www.TukwilaWA.gov From: Lauri Thoday <LauriThoday@AuburnMechanical.com> Sent: Wednesday, May 29, 2019 9:53 AM To: Rachelle Ripley <Rachelle.Ripley@TukwilaWA.gov> Subject: RE: Permit M18-0016 Good morning Rachelle, we are not scheduled to install the 3rd AC unit until the end of June, do I need to re -apply for a new permit or can I have this extended again? Thank -you for your assistance. Lauri Thoday Sr. Project Engineer Auburn Mechanical 2623 W. Valley Hwy N., Auburn, WA 98001 P 253.838.9780 l C 253.255.4996 www.auburnmechanical.com When Performance Counts Request for Extension # / G Current ;iration Date: uov "'-1 t Extension equest: rI Appio, J for /t J days Denicc ;roe: iL:c explanation) From: Rachelle Ripley <Rachelle.Ripley@TukwilaWA.gov- Sent: Tuesday, January 22, 2019 11:48 AM To: Lauri Thoday <LauriThoday@AuburnMechanical.com> Subject: RE: Permit M18-0016 Hi Lauri, You had an inspection on 12/7/18 so the current expiration date is 6/5/19. Let me know if you have any questions. Thank you! i Signature/Initials' ® 0 1{achelle Ripley Permit Coordinator I City of Tukwila 630o Southcenter Bl, Suite 100 I Tukwila, WA 98188 T: 206.433.7165 I F: 206.431.3665 Rachelle.Riplcy n)Iukwi.laWA.gov I http://www.TukwilaWA.gov From: Lauri Thoday <LauriThoday@AuburnMechanical.com> Sent: Tuesday, January 22, 2019 11:22 AM To: Rachelle Ripley <Rachelle.Ripley@TukwilaWA.gov> Subject: RE: Permit M18-0016 Good morning, once again this project has been delayed and we wont be installing the last unit until the end ofJune. What do I need to do to extend this permit again? Thank -you! Lauri Thoday Project Engineer Auburn Mechanical 2623 W. Valley Hwy N., Auburn, WA 98001 P 253.838.9780 I C 253.255.4996 www.auburnmechanical.com When Performance Counts From: Rachelle Ripley <Rachelle.Ripley@TukwilaWA.gov> Sent: Monday, August 27, 2018 12:26 PM To: Lauri Thoday <LauriThodav@AuburnMechanical.com> Subject: RE: Permit M18-0016 Hi Lauri, There was an inspection completed on 8/17/18 which automatically moved the expiration date out until 2/13/19. Let me know if you need anything additional. Thank you, Rachelle Ripley Permit Technician I City of Tukwila 630o Southcenter Bl, Suite 100 I Tukwila, WA 98188 T: 206.433.7165 ( F: 206.431.3665 Rachelle.Ripley@'Cuk.r I<1W .gov http://www.TukwilaWA.gov From: Lauri Thoday <LauriThoday@AuburnMechanical.com> Sent: Tuesday, August 21, 2018 12:42 PM To: Permits <Permits@TukwilaWA.gov> Subject: Permit M18-0016 Attn Building Official, We have a project that we are working for Boeing at the 9-08 building that has been extended to last thru January of 2019. Can we have an extension on our permit? 0 Q Thank -you! Lauri Thoday Project Engineer Auburn Mechanical 2623 W. Valley Hwy N., Auburn, WA 98001 P 253.838.9780 I C 253.255.4996 www.auburnmechanical.com When Performance Counts CAUTION: This email originated from outside the City of Tukwila network. Please DO NOT open attachments or click links from an unknown or suspicious origin. CAUTION: This email originated from outside the City of Tukwila network. Please DO NOT open attachments or click links from an unknown or suspicious origin. CAUTION: This email originated from outside the City of Tukwila network. Please DO NOT open attachments or click links from an unknown or suspicious origin. Q City of Tukwila Department of Community Development 5/2/2019 LAURI THODAY PO BOX 249 AUBURN, WA 98071 RE: Permit No. M18-0016 BOEING #9-08 9725 E MARGINALWAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/5/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/5/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Kandace Nichols Permit Technician File No: M18-0016 0 City of Tukwila Department of Community Development 7/2/2018 LAURI THODAY PO BOX 249 AUBURN, WA 98071 RE: Permit No. M18-0016 BOEING #9-08 9725 E MARGINALWAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/6/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/6/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0016 1?-• PERMIT COORD COPY o PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0016 DATE: 01/29/18 PROJECT NAME: BOEING #9-50 SITE ADDRESS: 9725 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Pt3 N\NU 1\V\iCgt Building Division Public Works ❑ "/A- I-3o-1v° Fire Prevention II Planning Division Structural Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/30/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 02/27/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: I tome Espanol Contact Safety & Health Claims & Insurance CWashington State Department of Labor & industries SEARCHi;" A-Z Index Help My L&] Workplace Rights Trades & Licensing AUBURN MECHANICAL INC Owner or tradesperson Principals THODAY, DAVID V, PRESIDENT JOHNSON, STACY ANNE, PRESIDENT JOHNSON, KIM PAUL, SECRETARY Doing business as AUBURN MECHANICAL INC WA UBI No. 600 074 968 PO BOX 249 AUBURN, WA 98071 253-838-9780 KING County Business type Corporation Governing persons STACY A JOHNSON KIM JOHNSON; RYAN HOWARD MCMAHAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. AUBURMI163BA Effective — expiration 01/01/1984— 09/12/2018 Bond FIDELITY & DEPOSIT CO OF MD Bond account no. LPM8047218 $12,000.00 Received by L&I Effective date 09/12/2001 09/01/2001 Expiration date Until Canceled Insurance Continental Western Ins Co $1,000,000.00 Policy no. CPA6015336 Received by L&I Effective date 09/29/2017 10/01/2016 Expiration date 10/01/2018 Insurance history Cit• Busl_r SEPA RE i.• } t.. 1 :iT Li 1 ._ s A .1. ❑]Mocnanicas tectrical lumbing Gas Piping of Tukwila SYM A CAP ABANDONED DUCTWOR Jj757066-00 DENSON F5A5 HP1/ 10/10 Br APPROYW DATE 5 �`-- 2725 P 86 sYM 5M10 5M450 REMAIN CAPPED 60/24 D 60 FD CAPPED FIFTH FLOOR HVAC PLAN SCALE: 1/8'=1•-0" APPRO.m DATE KGP RWS/EJC A-17500 10 12 -4 12 LEGEND 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: firEQUIPMENT NUMBER FOR MAINTENANCE & LABEL EQUIPMENT SE. SEE SCHEDULE ON SHEET M4. 2. SYMBOL FOR m v GENERAL NOTES FILE C Y Permit o. 1\41(6' —Ptah reviewr$ . •teal is subject to errors and omissions. Approval of construction documents does nct a :horze the violation of any adopted code or ordinance. Racal • REVIEWED FOR of approved Field opy an onditions is ac%nowiedge :CODE COMPLIANCE APPROVED FEB 01 2018 pR ACCEPTABILITY DRS 0131LN AND/OR SPECIFICATION 6 APPROVED TYPICAL By: Date: City of Tukwila BUILDING DIVISION REVISIONS No changes shall bl made to the scope of work witho prior approval of ROT T': iii 1 _ . • ar.i rl^� • , DLR Group n..I.$osr Erg. t .V.S, ...Jars M. CAUNRIS wu Km R. MURRAY DATE City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAW 292018 ERMIT CENTER REMOVAL ISSUE FOR CONSTRUCTION 08.15.17 MI 10.01.04 10.01.04 SATIRE 03( FIFTH FLOOR HVAC PLAN bKEY PLAN NO SCALE 33373-10 SYMBOL E [ATE 08.15.17 SHEET NATION: E/7/I017 10:58:54 IN AIRSAN COMPACT SILENCER R/A GRI (TYP 4) SYM 14/10 HP1 8 8 CT; TITUS jTSMA-AA 24" X 24" 10'0/160 CFM (10 PLACES) BY APPROVED DATE 24/16 CNI 2725 20/16 150 AFSD 24/12 TITUS ITSMA-AA 24" X 24" 10'0/300 CFM (2 PLACES) SYM REVISION 300 AFSD 280 280 ABANDONED IN N CE DUCT 10 10 24/16 1,A1 2 12 1SO W X X X 20/16 80 0/16 AFSD FIFTH FLOOR HVAC LAN - B SCALE: 1/8"=1.-O" Ety PAPROVED DATE A RECORD DRAWINGS MJC KMR/OS 10.01.90 F E10: RELOCATE DCMA J1557325-02I M.WONG RNS 01.16.06 ABANDONED IN 10/10 DLR Group ISSUE FOR CONSTRUCTION 08.15.17 ACCEPTABILITY THIS OESICN M10/OR SPEC61CI110N R APPMOWTI DRAWN M. CA MR15 R. MURRAY aTE 10.01.90 10.01.90 SUIEMILE 18 �I II KEY PLAN O NO SCALE GENERAL NOTES 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EOUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 2. tSI SYMBOL FOR TYPICAL. RECEIVED CITY OF TUKWILA JAN 2 9 2018 PERMIT CENTER ROOF 'REVIEWED FOR 4ODE COMPLIANCE APPROVED SECTION S FEB 01 2018 LOCATE TO CLEAR DIAGONAL BRACING LEGEND EXIS NEW City of Tukwila pap DIVISION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AND STC 45 PARTITION STC 45 PARTITION STC 50 PARTITION REMOVAL FIFTH FLOOR HVAC PLAN CURRENT 337 3310 SYMBOL DATE 08.15.17 4FET 5M12 M507 TT S TSMA-AA 24" X 24" 0' NECK/160 CFM EACH AIRSAN COMPACT SILENCER R/A GRILLE (TYP 4) ISSUE FOR CONSTRUCTION 08.15.17 STY Br APPROVED DATE 5M121M507 500 150 250 250 O M(,TCH LINE (FOR CONTINUATION SEE SHEET 5M FD HP5C1 16/12 44/16 60/24 AIRSAN COMPACT SILENCER R/A GRILLE (TYP 4) FIFTH FLOOR HVAC PLAN — A SCALE: 1/8"=1.-0" DLR Group N<hr"""« &'W ' a vi..n r".".. SYM REN90M 0. APPROVED DATE 51111 11111�ars�r�•11 � !l�l�7iGs�� 16 10 150 2650 0 TUS #TSMA-AA 24" X 24" 7MER, 10"0 NECK (TYP 8) A CAP ABANDONED DUCTWORK Jj757066-00 KGP EJC G REPLACE HVAC UIT N1 ECC J1785060-00 KGP RWS/00T 10.12.01 150 1 'HP1le� ASBESTOS NOTIRCADON wr.orErw7rArrr.rr YMWYY�As1,M+�r..A6 rr r wwiiw` r aErrr"YV b S Ykhiw"I Y Y mar �s.l Y Y wNr LEGEND: EXISTING WALLS NEW FULL -HEIGHT PARTITION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED HY OWNER PROGRAM PERIMETERS AN STC 45 PARTITION STC 45 PARTITION U I STC 50 PARTITION o-i I KEY PLAN NO SCALE FFSD AOAF ABANDON IN PLACE — AFSD CAPPE FO 16/12 51412,RF i4520 17/40 730/16 5A112 L REMOVAL ACCEPTABILITY TIKS DESK?1 AND/OR SPECKOATION 5APPROWD DRAM EWE Y. CAMPS 10.0190 WEDKJD R. MURRAY 10.01.90 SUI E 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. TYPICAL. CONSTRUCTION NOTES: I-_-> REMOVE 24/36 MOTORIZED DAMPER. ABANDON IN PLACE HP 5C1 ES 2/1 lT r.1, JOO 1;50/30 J L RECEIVED CITY OF TUKWILA JAN 29 2018 PERMIT CENTER 0 5/4 111 Fly R COD ii \u • PARTIAL FIFTH FLOOR HVAe SCALE: 1/4"=1"- FIFTH FLOOR HVAC PLAN TYPICAL 5 PL ty of Ty ila CURRENT REVISION 33373-10 SHEET AFSD 26/16 20/16 2 SD60. OA1E K 09.15.17 d7A710N: 8/7/2017 11:02:47 AM m /1 1/2" PLUG (TYP) /' • I Y • 2-9 0-10 1-9 / N^^N N 1 • N 8 1 A'— 1-9 1 2 N� -0 10•-0' 10.-0' d /o /o 4.0 � [' 010 �2 -9 00-10 - 0 en j� N; 2-9 "0-10 -2-9 "0-10 NLel 64 APFNOND 04 /^ NI -9 rn , 1 1-9 RATE 10 sYM cY • 1-9 a o 9 0 CO FIRE VALVE UV908-5A 4•-0" +-• 1 109 --0' / �1-7 1-9 N N I 21 12-5 5-0 04 -• N 1 1/2' PLUG 18.-0" 2 2 21 REVISION 10•-0" 1 1/2' PLUG (TTP) ':I 1 8 8 6-10 9-6 9-6 i 0 0 8 4- 2.-0" 5,-6" 10 2"CAP 5TH FLOOR PLANALE:1/8 SCALE: 1/8"= 1.-0" �! RATE A EIO: RELOCATE OCMA J/557325-02 M.WONG RWS 01.16.06 10-0 1-9 1 0-10 1-91 0 0-10 10,-0" 2-CAP 0-10 J7 O 10.-0 0-10 N 0-10 0-9 Ne 1 1-9 N� i 1 1 0-9'd�n 3-9 4-9 No 9 1 1/2' PLUG :>1 0-10 N i 0-10 1-9 0-9-9 - n Nb 1 0-9 - 0-10_I,& 0-10 9 m 1 C 1 n 8 NI 8 0-9 NO. 9-6 i'019 N.1 1 •�1- 0-10 10-0 11 0-9 � 0-9 1 y'p_g s.4 NY N� -10 NI N I 1-9 0-10 NN t. 010 -9'-0-10 o Ni 9d'- 0-10 b-9 CO 1 0-9 N� 8 10-0 -6 09 4 N ▪ 0 i llama 04 1-9•-4 r• 0-10 \ 2-CAP 1-1 1 1/2' PLUG • No 1 1 ;4 0-10 1-Y No 0 210 ,i': 9 I'' I 1 1/2PLUG • REMOVAL ACCEPTABILITY MIS OESKII AND/OR SPECIFICATION IS APPRD%4D DRAIN KBUN DATE 3.10.01 OIEOCED C3WIw1 3.10.01 O LEGEND: - SPRINKLER HEAD , PENDENT IN LONE SPRINKLER HEAD, UPRIGHT AUTOMATIC SPRINKLER RISER HALON SYSTEM AUTOMATIC DISCHARGE STATION SPRINKLER HEAD, SIDEWALL, UPRIGHT GENERAL NOTES: RECEIVED CITY OF TUKWILA JAN292018 P !RMiT CENTER REVIEWED FOR CODE COMPLIANCE A??ROV ED FEB 01 2018 City of Tukwila BUILDING DIVISION ® DLR Group ISSUE FOR CONSTRUCTION 07.14.17 SUBTITLE FIRE PROTECTION 5TH FLOOR PLAN KEY PLAN O SCALE: NONE CURRENT REVISION 33373-10 SluaoE B fI TE 08.15.17 SHEET RADON: 8/7/2017 11 LEGEND: 18-0 7-0 1 1 -1 s m �I li 1 —E m — — Pia MBii,. I_ I� ` n n oT ,' c . fammammonlinill •• 1• m ell MD MEM IMO. ivii � it m m co co m N 1 I qN`6 1 • • —Ci. � X X � >` � i — NI T t ti f• t a `�� ' T I w , 1 a DETAIL "' 11 = = R A -• 8 -' 8 i I L n • 5-9 1/2y�� N- � ! 1 ^J i r • • • I ��'.. I1, 23N ■ �1 T o t� } MEOW I I N - 1.6 • • �� (-9 r i ' • X _ 1 I x 4 10-O loS _ 11 • = ^_ ��� o - ,fir •~ 6-0 8-0 10-0 h0 6-0 1 1 I o ' I A; -- Np I „Ai; �.r�llr L_- �l M�11I1I —, Ni—. • NZ hir a j I • Np Nif ---- • N 2 r "'''Ij' 0 • ' o _ 328 1-6-0. 126 TI I , , N +� ~ �1 + IMF. _+a-� • r I[w '•Mill ic�1�1 I eV 11 `1 1 8 8 8 • o - �I. IIII�1�1� 1 1 1 1 ZiniiMil.1 MINI ^ 1 L• NI a x -I1111111111. _� 11-• I 4 �• • �CO WWIMINIMPii1 M EM I I OI I I • it N ^ �,,. ^ N'I N N _� _�^ • I MI ESIVILEI 9 9-0 IMEI GiiEl7 I__I>J r � _�_ , AIM_ N. ,t,s,• N • c- L mummorimiga N0 Nb Na ^ N- •'� A I `� ■ I f l u n Na —ter I 1111' , TO VLAVE #908-58 AT 0, NCA COL. D/18 stu REVaON 61 DATE STM HENSON 5TH FLOOR PLAN SC81F: 1/8"=1 BY AN1ghD DUI A INSTALL AMS N JSF AREA Jr785146 SLB RWS 12.03.98 F MODERNIZATION OF ELEVATORS 33373-10 DER GROUP CLN 08.15.17 ACCEPTABILITY 11#S DESP4 NID/0R SPECEICATION 6 WPROYED 0c1 SfE • SPRINKLER HEAD , PENDENT IN UNE --o— SPRINKLER HEAD, UPRIGHT —®-- AU1OMATIC SPRINKLER RISER HALON SYSTEM AUTOMATIC DISCHARGE STATION - SPRINKLER HEAD. SIDEWALL, UPRIGHT GENERAL NOTES: 1 SPRINKLER PIPE TO BE SCHEDULE 40 BLACK STEEL WITH BLACK CAST STEEL FITTINGS. 2 SPRINKLER HEAD TO BE 155• PENDENT WITH CHROME RECESSED ESCUTCHEON. RECEIVED CITY OF TUKWILA REVIEWED FOR JAN 2 9 2018 CODE COMPLIANCE ALI'PRoVED ERMIi' CENTER FEB 01 2018 City of Tukwila B ILDING DIVISION roup ISSUE FOR PERMIT 08.15.17 REMOVAL FIRE PROTECTION CURRENT REVISION KEY PLAN MTE 33373-10 SHEET S1TIB0. 0 08.15.17 LEGEND: •-0 10-0 1 N I — 0 -10 J 0 10-0 10- 10-0 10-0 -1 - 0- • ^3-4 0-4 1 1/2' PLUG (TIP) A I. INC VTC PROJECT J001437-00 sn mm a cFH N I •wm.e Prz 21 2 1-2 2 2 PLUG PLUG PLUG 5TH FLOOR PLAN SCALE: 1/8"=1'-0" w O 212 18-0 212 •-1 I sisAC' iAS/ w 2' • 1/2' PLUG (TYP) 14 15 16 17 18 19 ACCEPTABILRY DOS DEW 611166 war K.BUN GENERAL NOTES: SPRINKLER HEAD , PENDENT IN UNE SPRINKLER HEAD, UPRIGHT AUTOMATIC SPRINKLER RISER HALCN SYSTEM AUTOMATIC DISCHARGE STATION SPRINKLER HEAD, StLEWALL, UPRIGHT CONSTRUCTION NOTES: REMOVE FIRE SPRINKLERS AT TOP OF HOISTWAY, REVIEWED FOR ;1 CODE COMPLIANCE APPROVED FEB 01 2018 City of Tukwila BUILDIN ' (VISION RECEIVED CITY OF TUKWILA JAN 29 2018 PERMIT CENTER Nsfw.swe t*$ ('q$ Plwwq xteus ISSUE FOR CONSTRUCTION 08.15.17 REMOVAL as 09-0 46 °irmoOHV SMILE 09-a3-ss 5TH FLOOR FIRE PROTECTION PLAN 5M260 5M261 5M262 KEY PLAN sae WIC wr ens m IsrA mIe1/".e9P1 out 6.4 10"CTWS 16 15 14 13 ti r RV n RFM10 M502 10"CTWS 18/18AD Ems§ 5M11,RFM1OM520 60/60 10" BUTTERFLY VALVE (3 PLS) 12"X10" ECCENTRIC RED PIPE FLAT ON TOP (3 PLS) 0 ` 54x24 `-60/60 (BELOW) DAMPER RFM10 M502 1Q SEE DETAIL 44/40 OPNG RFM101M524 1014 EAT AND 0" EQUALIZING LIIE 12" TEE 12" X 10" RED 10" BUTTERFLY VALVE (3 PLS) CAP FOR FU _ I =14" SAN DRA 1 f G-- I' pfa)``i` �1 ,--, i =CiWS v R"CTWR 8 CTWR TAPE TRACE NSULATE (TlP) CAP FOR FUTURE 10" 8"CTWR D CONDUIT ROUTING (REF) A plb 12"CTWS 8"CTWR HB 12" LATERAL (2 PLS) 8"CTWR 8"CTWR 8"CTWR RFM10 RFM10 4"FD 2" VENT NFHB THRU ROOF L D9 10" CTWS 0 CD HBO 0 SEE PENTHOUSE MECHANICAL I ROOM PLAN BELOW 0 PARTIAL ROOF PLAN CONDUIT ROUTING (REF) RFM10 M502 PIPE DOWN TO 5TH FLOOR SEE SHT. 5M62 PENTHOUSE MECHANICAL ROOM PLAN 1/4"=1.-0" SUPPORT BEAM 12"X8" RED FLG (REF) �(4 PLS) 8"CTWR 10"CTWS 12"CTWS H.D. tea= 1100 GPM - FLOW CONTROL VALVE (2 PLS) 12"CTWR CAP FOR FUTURE RFM10 M502 12"X12"X8" TEE (2PLS) PIPE DOWN TO 5111 FLOOR SEE SHEET 5M62 SECTION A 1/4"=1'-0" 05 APPROVED DATE m REa5g1 12"X8" LR RED EL RFM10 RFM10 Tn APPROVED DATE RECORD DRAWING K11R/DS 10.1.90 6"VTR 60/60 MOTOR OPERATED DAMPER AA�D7 600 RD AND OD ill ItiIaU 5M11,RF 41 60/60 RFM10 M502 RFM10 M502 LEGEND REFERENCE DRAWINGS 09-008-RF11.DWG 09-008-M520.DWG 09-008-M330.DWG 44/40 OPN 42/30 SE o DETAIL RFM10 M521 REVIEWED FOR 4 CODE COMPLIANCE APPROVED FEB 01 2018 v cFITCAp SEE DETAIL 12% 31 RFM1OIM521 60/60 f R1D8A 1808 AD REMOVAL 1 ACCEPTABILITY INS DESIGN ONO/OR SPECf1CUl0N IS APPROVED [PAWN CN CHECKED a1E 06.06.17 SUBTITLE GENERAL NOTES SEE SHEET RF-11 FOR SHEILDING DETAILS. 2.6KW FAN FORCED UNIT HEATER W1TH BUILT-IN THERMOSTAT, 277V/60HZ/10, CHROMALOX TYPE LUH OR APPROVED EOUAL. 3 NOT USED 4. ROOF PIPE PENETRATION SEE DETAILS ON SHEET RF-11. 5. ROOF DUCT PENETRATION SEE DETAILS ON SHEET M520. 6. SEE ROOF EQUIPMENT MOUNTING DETAILS ON SHT. S-22. City of Tukwila BUILDING DIVISION DLR Group w....,,. Tw4..", T PARTIAL ROOF PLAN CONSTRUCTION NOTES REMOVE EXISTING WALL MOUNTED PROPELLER EXHAUST FAN. RECEIVED CITY OF TUKWILA JAN 29 2010 PERMIT CENTER ISSUE FOR CONSTRUCTION 08.15.17 CURREM RE`ASION 33373-10 SHEET swea OM( C 08.15.17 iRATION: 8/4/2017 &35 45 AM SYN NO 2. 4. MECHANICAL LEGEND MECHANICAL LEGEND MECHANICAL LEGEND MECHANICAL LEGEND MECHANICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC HVAC HVAC A ANCHOR AAV AUTOMATIC AIR VENT AD ACCESS ODORANGULAR DOWN ADD DISCHARGE AIR FOIL WHEEL AFF ABOVE FINISHED FLOOR AP ACCESS PANEL AUD ANGULAR UP DISCHARGE AVG AVERAGE BI BACKWARD INCLINED WHEEL BDD BACK DRAFT DAMPER BFP BACKFLOW PREVENTER BHD BOTTOM HORIZONTAL DISCHARGE BHP BRAKE HORSE POWER BOO BOTTOM OF DUCT BOP BOTTOM OF PIPE DOS BOTTOM Of STEEL BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNIT PER HOUR BV BUTTWELD C COMMON Cv FLOW COEFFICIENT 'C TEMPERATURE DEGREES CELSIUS CAP CAPACITY CC COOLING COIL CCW COUNTER CLOCKWISE ROTATION CFM CUBIC FEET PER MINUTE CI CAST IRON ( CENTER LINE CONN CONNECTION CPLG COUPLING CV CLOCKWISE ROTATION DA DIRECT ACTING DB DRY BULB TEMPERATURE DBD DOWN BLAST DISCHARGE DIA, > DIAMETER ON DOWN DOWNSPOUT DWG DRAWING dB DECIBELS EA EXHAUST AIR / EACH EAT ENTER AIR TEMPERATURE ('F) EFF EFFICIENCY ELL ELBOW ELEV, EL ELEVATION ESP EXTERNAL STATIC PRESSURE EVAP EVAPORATOR EVT ENTERING WATER TEMPERATURE EXH EXHAUST EXIST EXISTING EXT EXTERIOR / EXTERNAL 'F TEMPERATURE - DEGREES FAHRENHEIT FC FORWARD CURVE WHEEL FLR FLOOR FOB FLAT ON BOTTOM FUOF T FACE OF FLANGE FDIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOT FLAT ON TOP FPM FEET PER MINUTE FS FLOW SWITCH LAT LEAVING AIR TEMPERATURE C'F) CBS, # POUNDS LVT LEAVING WATER TEMPERATURE ('F) MA MIXED AIR MAX MAXIMUM MBH HEAT CAPACITY BTU PER HOUR X 1000 MCC MOTOR CONTROL CENTER MIN MINIMUM MOV MOTOR OPERATED VALVE MTD, MTG MOUNTED, MOUNTING NC NORMALLY CLOSED NIC NOT IN CONTRACT NO NORMALLY OPEN / NUMBER NTS NOT TO SCALE NPSH NET POSITIVE SUCTION HEAD OA OUTSIDE AIR DBD OPPOSED BLADE DAMPER OF OVERFLOW DS8Y OUTSIDE SCREW AND YOKE 00 OUTSIDE DIAMETER PBD PARALLEL BLADE DAMPER PDd P PRESSURE DROP OR DIFFERENTIAL PRESSURE POS POSITION PRESS PRESSURE PRV PRSSURE REGULATING VALVE PS PRESSURE SWITCH PSIG PRESSURE - POUNDS PER SQUARE INCH, GAUGE PSV PRESSURE RELIEF (SAFETY) VALVE RA REVERSE ACTING (CONTROLLER) / RETURN AIR RECT RECTANGULAR REF REFERENCE RH RELATIVE HUMIDITY RM ROOM ROT ROTATION RPM REVOLUTIONS PER MINUTE ROD REQUIRED RTN RETURN SA SUPPLY AIR SCFM CUBIC FEET OF AIR, AT STANDARD CONDITIONS SHC SENSIBLE HEAT CAPACITY SOSHF SCREENEDSENSIBLE HEAT OPENINGFACTOR SOV SOLENOID OPERATED VALVE SP STATIC PRESSURE SO SQUARE SS STAINLESS STEEL STL STEEL SW SOCKET VELD SUCT SUCTION SV SAFETY RELIEF VALVE TDH TOTAL DYNAMIC HEAD <FEET OF WATER) TEMP TEMPERATURE TH TOTAL HEAD (FEET OF WATER? MC HEAT CAPICITY m�0, I00DN THD TOP HORIZONTAL DISCHARGE THRD THREADED ELBOW ® THERMOSTAT, REMOTE, CEILING INDICATES SIIDETSFOVNR ���, viTHATNIt�NG vIX1C�T[SQUARE 21 4 IL � 24/122-, v\I DUCT SHOWN IN SECTION ARROW POINTS TO SIDE CALLED OUT FIRST 1 RECTANGULAR DUCT, RADIUS VANED ELBOW Q HUMIDISTAT, WALL b 24) 9 ., —► , � HUMIDISTAT CEILING 24> ROUND DUCT, NUMBER INDICATES DIAMETER J r EXTRACTION GRID �r ` 24/12> 9 OVAL DUCT, FIRST HUMBER INDICATES W4---144 4o DUCT TYPE SMOKE DETECTOR 24/12> MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER FLEXIBLE DUCT 1 1 4D DUCT TYPE HEAT DETECTOR �"'SUPPLY AIR DUCT SQUARE OR RECTANGULAR ELBOW FACING TdWARDS FLEXIBLE DUCT CONNECTION O J 4 STATIC PRESSURE REGULATOR 1111111 ELBOW FACING AVAYQUARE OR RECTANGULAR too CFM REGISTERPNJD CFM AIRFFLO� GRILLE, L� 1_ EXHAUST, RETURN OR SUPPLY AIR DUCT SIDEVALL RETURN/EXHAUST AIR GRILLE OR } ' } TE E T gE MP RA UR NSOR ,HUMIDITY SENSOR, ]IUCT MOUt ED 1I/ ROUND ,ELBOW FACING TOWARDS f� I00 CFM REGISTER AND AIR FLOW I I — LINED DUCT EXHAUST RETURN OR SUPPLY DUCT, ROUND, ELBOW FACING AWAY i~' 100 CFM SCREENED OPENING AND CFM AIR FLOW SOUND ATTENUATOR I il� EXHAUST AIR OR RETURN AIR DUCT SQUARE OR RECTANGULAR, ELBOW FACING TOVARDS �-► 400 SUPPLY OUTLET, CEILING TYPE DIFFUSER OR GRILLE, SQUARE OR RECTANGULAR AND CFM AIR FLOW (SEE NOTE 4) CFM (� v CENTRIFUGAL FAN I� EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING AVAY �' 1 > ) SUPPLY OUTLET,TYPE, ROUND FLOW CEILING �Jaoa CFM FAN, INLET GUIDE VANES TRANSITION RECTANGULAR TO RECTANGULAR K=_=1 LINEAR DIFFUSER AND CFM AIR FUN/CENTRIFUGAL 100 CFM (SEE NOTE 4) 1ST CHARACTER V = VARIABLE AIR VOLUME TERMINAL UNIT 2N0 CHARACTER F = FAN POWERED UNIT C = SHUTOFF UNIT 3RD CHARACTERS E ELECTRIC FEAT v = HOT WATER HEAT .L1P" TRANSITION AT TAKE OFF RETURN REGISTER OR GRILLE, S too0 cr CFM DIETl1ST CEILING TYPE AND CFM AIR FLOW TRANSITION SQUARE OR RECTANGULAR TO ROUND OR OVAL �"ti- RETURN/RELIEF GRILLE, CEILING TYPE, ,' 1 NON -DUCTED C = NO FEAT COIL �7—UP --T� }I I I} ACT OFFSET UP OR DOWN [ UNIT HEATER, HORIZONTAL1 1 DDVN - NARK NUMBER R OPPOSED BLADE DAMPER UNIT HEATER, VERTICAL PROJECTION a PARALLEL BLAME DAMPER SUPPLY AIR FLOW DIRECTION VOLUME DAMPER RETUR OUTSIDE OR EXHUAST AIR FLOVDIRECTION ___','� f \ 1 nal DUCT DAMPER, MOTOR OPERATED (ELECTRIC OR PNEUMATIC) THERMOSTAT, WALL BACK DRAFT DAMPER (ALLOWS CrF-BUB+ FLOW IN DIRECTION ARROW) � "K NIGHT TIERMOSTAT FT FEET FV FACE VELOCITY FPM GPM GAL GALLONS GALLONS PER MINUTE GALV GALVANIZED GA GAGE, GAUGE HC HEATING COIL HD HEAD - FEET OF WATER HORIZ HORIZONTAL If HORSEPOWER HPC HIGH PRESSURE CONDENSATE FIR HOUR HVAC HEATING, VENTILATING AND AIR CONDITIONING HPU HEAT PUMP UNIT NG HPWR HEAT PUMP WATER RETN HEATHTG PUMPWATER RUPURY TOD TOP _ TOS TOP OF S7� ��pp��FOR TOP TOPS F PE€VIEVtltD TP I TS TTEMPE 1�4 I1CNON+PLIANC TSP TOTAL STATIC p�P `,� TV TURNING VANEfaO V tom© TYP TYPAL [['[[ UBD UP i AST DI�LIIARI((�� SE 0 1 2018 VAV VARt BLE AIR VOLUME VD VOL ME DAMPER VP VEL CITY P CAL RE �fTukwila VTAT VEN VERITO A Is a • VTR VEN f a1' .G DIVISION E BDD AD OR AP IL 1-7 ACCESS DOOR (AD) OR ACCESS PANEL (AP) i ❑ THERMOSTAT, CEILING FD i i i FIRE DAMPER (1 HOUR ) f !ED f F. MIR FIRE DAMPER ( 2 HOUR ) I T02 f fES� DESIGNATES APPEARING MECHANICAL ID INSIDE DIAMETER IE INVERT ELEVATION CI�F IGV INLET GUIDE VANE 03 TEMPERATURE Cr ��jq, {INCHES OF WATER) T ry(1�i9 O EQUIPMENT SCHEDULES. SEE DRAWINGS STARTING SCHEDULES G M-3 FOR DESCRIPAION. SEE DRAWING M-2 FOR ABBREVIATIONS OF PIPING, IDENTIFICATIONS AND SPECIALTIES. IN INCHES KV KILOWATT KVA KILOVOLT -AMPERE JAN 2 9 2018 � -- DER Group SEE CONTROL SCHEMATIC(S) FOR ADDITIONAL ABBREVIATIONS AND SYMBOLS RELATING TO CONTROL SYSTEMS. DIFFUSERS WITHOUT ARROWS TO INDICATE AIR FLOW DIRECTION ARE FOR FLOW IN ALL DIRECTIONS (TWO DIRECTIONS FOR NEAR DIFFUSERS). ARROWS ARE USED TO INDICATE DESIRED AIR FLOW DIRECTIONS IN OTHER CASES. REVISION BY MPDOVED DATE SYM REWWSKN IT ,APPROVED HATE A RECORD DRAWINGS 86062 NJC KMR/DS 1001.90 ACCEPTABILITY THIS DESIGN ANO/Qt SPECIFICATIRI 1S APPROVED PERMIT CENTER DDRRAWN L1LEKL6 0 606.17� SUBTITLE 9-08 MECHANICAL DRAWING LIST MI HVAC LEGEND & ABBREVIATIONS M2 PIPING LEGEND M3 EQUIPMENT SCHEDULES M4 EQUIPMENT SCHEDULES M5 EQUIPMENT SCHEDULES M6 EQUIPMENT SCHEDULES M7 AIR FLOW DIAGRAM M310 HEATING/COOLING PIPING DIAGRAM M3ll PIPING DETAILS M320 AIR SYSTEM CONTROL DIAGRAM M321 VENTILATING FANS -CONTROL DIAGRAMS M322 HEATING/COOLING CONTROL DIAGRAM M323 HVAC SYSTEM WATER CONTROL SEQUENCE 1M10 LOWER MECHANICAL ROOM PLAN 1M11 UPPER MECHANICAL ROOM PLAN M500 MECHANICAL ROOM SECTIONS M501 MECHANICAL ROOM SECTIONS IM12 FIRST FLOOR HVAC PLAN - A 1M13 FIRST FLOOR HVAC PLAN - B 1M14 FIRST FLOOR HVAC PLAN - C 2M11 SECOND FLOOR HVAC PLAN - A 2M12 SECOND FLOOR HVAC PLAN - B 2M13 SECOND FLOOR HVAC PLAN - C 3M11 THIRD FLOOR HVAC PLAN - A 3M12 THIRD FLOOR HVAC PLAN - B 3M13 THIRD FLOOR HVAC PLAN - C 4M11 FOURTH FLOOR HVAC PLAN - A 4M12 FOURTH FLOOR HVAC PLAN - B 4M13 FOURTH FLOOR HVAC PLAN - C 5M11 FIFTH FLOOR HVAC PLAN - A 5M12 FIFTH FLOOR HVAC PLAN - B 5M13 FIFTH FLOOR HVAC PLAN - C RFM10 PARTIAL HVAC PLAN M502 ROOF SECTIONS AND DETAILS M160 GENERATOR FUEL AND TANK PIPING M161 PUMPING STATIONS IM61 FIRST FLOOR PIPING PLAN - A IM62 FIRST FLOOR PIPING PLAN - B IM63 FIRST FLOOR PIPING PLAN - C 2M61 SECOND FLOOR PIPING PLAN - A 2H62 SECOND FLOOR PIPING PLAN - B 2M63 SECOND FLOOR PIPING PLAN - C 3M61 THIRD FLOOR PIPING PLAN - A 3M62 THIRD FLOOR PIPING PLAN - B 3M63 THIRD FLOOR PIPING PLAN - C 4M61 FOURTH FLOOR PIPING PLAN - A 4M62 FOURTH FLOOR PIPING PLAN - B 4M63 FOURTH FLOOR PIPING PLAN - C 5M61 FIFTH FLOOR PIPING PLAN - A 5M62 FIFTH FLOOR PIPING PLAN - B 5M63 FIFTH FLOOR PIPING PLAN - C UGM110 FOUNDATION PLUMBING PLAN UGM111 TOILET AREA FOUNDATION PLUMBING PLAN IM111 FIRST FLOOR TOILET ROOM PLANS 2M111 SECOND FLOOR TOILET ROOM PLANS 3M111 THIRD FLOOR TOILET ROOM PLANS 4M111 FOURTH FLOOR TOILET ROOM PLANS 5M111 FIFTH FLOOR TOILET ROOM PLANS M330 PLUMBING RISER DIAGRAM 1M260 FIRE PROTECTION - FIRST FLOOR 1M261 CO2 FIRE SUPPRESSION - FIRST FLOOR 2M260 FIRE PROTECTION - SECOND FLOOR 3M260 FIRE PROTECTION - THIRD FLOOR 4M260 FIRE PROTECTION - FOURTH FLAIR 4M261 CO2 FIRE SUPPRESSION - FOURTH FLOOR 5M260 FIRE PROTECTION - FIFTH FLOOR M340 FIRE PROTECTION - RISE DIAGRAM M520 HVAC SECTIONS AND DETAILS M521 HVAC SECTIONS AND DETAILS M522 PIPING DETAILS M523 PIPING DETAILS M524 PIPING SECTIONS AND DETAILS M525 EQUIPMENT MOUNTING DETAILS M527 HVAC SECURITY DETAILS M528 HVAC SECURITY DETAILS ISSUE FOR CONSTRUCTION 08.15.17 HVAC LEGEND AND ABBREVIATIONS T REVISION 33373-10 SYMBOL C DATE 08.15.17 8/7/2017 111802 AM MARK SERVES COOLING CAPACITY E.A.T. SUPPLY FAN DATA SEER CONDENSER FAN DATA COMPRESSOR DATA ELECTRICAL DATA PHYSICAL DATA BASIS OF DESIGN (BARD) NOTES TOTAL (MBH) SENS. (MBH) DB/WB (' F) TOTAL SUPPLY CFM MIN OA CFM EXT. S.P. (IN W.G.) FAN RPM FAN HP V PH MCA MOCP DIM DxWxH (IN) WEIGHT (LBS) NO. FLA EA EAT (DB ' F) NO. RLA EACH REFRIGERANT WACU-1 EMR 1 &2 36.4 25.8 80/67 1100 25 0.30 1100 1/3 10.0 1 1.5 95 1 11.1 R-410A 208 3 23 30 17.1x38.2x74.6 450 W36LA 1,2 WACU-2 EMR 3 30.0 21.6 80/67 1000 25 0.45 1100 1/3 10.3 1 1.5 95 1 7.5 R-410A 208 3 19 20 17.1x38.2x74.6 420 W30AA 1,2 WACU-3 EMR 4 & 5 36.4 25.8 80/67 11000 25 0.30 1100 1/3 10.0 1 1.5 95 1 11.1 R-410A 208 3 23 30 17.1x38.2x74.6 450 W36AA 1,2 NOTES: 1. ECONOMIZER W/CONTROLLER, THERMOSTAT. 2. CONTRACTOR TO VERIFY PANEL LOCATION BASED ON UNIT LOCATION. HEAT PUMP (HP) SCHEDULE MARK NUMBER FAN PERFORMANCE FILTER (SPECIAL DETACHED) AIR FlLI� @8KS AT WATER FLOW CONTROLDASS1' COOLING PERFORMANCE HEATING PERFORMANCE REMARKS MAX. EXT. STATIC MOTOR FLA SIZE FACEQ L JAX-FSP ININAL WG CFM SIZED / OTHER GPM CONDENSER FT. WO SIZE HOSE LENGTH PSI RANGE RATEOGPM HOSE SET P N / DB/WB EWi 'Fi TOTALMBH SENSIBLE MBH HT. REJECT POWERINPUT KW LATF EAT 'f TOTALBHEAT HEAT MB ABSORBED POWER INPUT KW MANU./MODEL SIZE QUANTITY HP-1 486 0.5 0.86 1-24x24 120 0.3 75/6"0 PLENUM 3.0 3.4 1/2" 36° 2-32 3 K10-2DS 80/67 85 14.3 10.3 19.1 1.45 65 65 17.6 12.6 1.49 (4) MACQUAY/CCH 15A 77 HP-2 955 0.5 1.0 1-24x24 240 0.3 145/7'0 PLENUM 6.1 4.6 3/4' 36" 2-32 6 K10-2FS 80/67 85 29.3 21.8 39.5 2.99 65 65 37.0 26.2 3.19 (1) MACQUAY/CCH 30A 191 HP-3 1275 0.5 1.8 1-24x24 320 0.3 190/8"0 (5) PLENUM 8.6 10.7 3/4" 36" 2-32 9 K10-2FS 80/67 85 41.7 31.4 55.8 4.1 65 65 54.0 39.3 4.30 (1) MACOUAY/CCH 42A 44 HP-4 1940 0.5 2.6 2-24x24 240 0.3 290/0 PLENUM 12.8 9.8 1" 36" 2-32 13 KI0-2HS 80/67 85 61.3 46.7 82.7 6.3 65 65 60.1 43.0 5.02 (1) MACQUAY/CCH 60A 9 HP-5 800 0.72 2.4 1-24x18 240 0.3 160/8"0 PLENUM 6.2 11.08 1' 36' 2-32 6 K36-2HS 80/67 85 24.4 17.5 30.9 - 65 65 28.1 21.5 MACQUAY/WCCW 24 1 (1),(2),(3),(4) NOTES 1) R-410A REFRIGERANT 2) 460/3PH, 5.3 MCA (3) 14.7 EER (4) 4.23 COP AIR DIFFUSER / REGISTER / GRILL SCHEDULE MARK NUMBER TYPE MATERIAL FINISH FACE SIZE INCHES INLET/NECK SIZE INCHES MAXIMUM NOISE COEFFICIENT MAXIMUM TP INCH WG MAXIMUM SET CFM REMARKS CD-1 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 60 33 .060 190 KRUEGER 6404F23 CD-2 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 80 33 .110 275 KRUEGER 6404F23 CD-3 SQUARE CEIUNG DIFFUSER STEEL WHITE 24x24 100 36 .130 425 KRUEGER 6404F23 CD-4 SQUARE CEIUNG DIFFUSER STEEL WHITE 24x24 120 36 .127 550 KRUEGER 6404F23 CD-5 SQUARE CEIUNG DIFFUSER STEEL WHITE 24x24 140 48 .240 950 KRUEGER 6404F23 RG-1 EGG CRATE CEILING RETURN GRILL STEEL WHITE 24x24 24x24 29 .150 800 KRUEGER EGC-JNSF SG-1 EGG CRATE CEIUNG SUPPLY GRILL STEEL WHITE 24x24 22x22 --- .150 2900 KRUEGER EGC-JNSF SG-2 PERFORATED CEILING SUPPLY GRILL STEEL WHITE 24x24 60 34 .080 220 KRUEGER 6590F23 SG-3 PERFORATED CEILING SUPPLY GRILL SILLL WHITE 24x24 80 43 .200 380 KRUEGER 6590F23 SG-4 PERFORATED CEILING SUPPLY GRILL STEEL WHITE 24x24 100 44 .210 540 KRUEGER 6590F23 SG-5 SUPPLY GRILL STEEL WHITE 16x10 25 .120 720 TITUS SERIES 270 SG-6 SUPPLY GRILL STEEL WHITE 12x6 23 .120 280 TITUS SERIES 270 SG-7 SUPPLY GRILL SILLL WHITE 16x6 23 .100 400 TITUS SERIES 270 SG-8 SUPPLY GRILL STEEL WHITE 30x18 21 .100 2000 TITUS SERIES 270 EG-1 EXHAUST GRILL SELL WHITE 14x8 29 .150 450 TITUS CORE 8F EG-2 EXHAUST GRILL STEEL WHITE 6x5 26 .065 50 TITUS CORE 23 EG-3 EXHAUST GRILL STEEL WHITE 8x6 29 .100 130 TITUS CORE 8F EG-4 EXHAUST GRILL STEEL WHITE 12x8 26 .040 280 TITUS CORE 23 EG-5 EXHAUST GRILL SILEL WHITE 18x16 32 .110 720 TITUS CORE 23 EG-6 EXHAUST GRILL STEEL WHITE 24x16 33 .180 1200 TITUS CORE 23 EG-7 PREFORATED CEILING EXH GRILL STEEL WHITE 24x24 12x12 29 .150 600 TITUS 8F TYPE 3 HEAT PUMP ID NUMBERS HP1 HP2 HP3 HP4 HP5 HP1A4A HP4C2 HP1A9 HP2B4 HP3A9 HP4A9 HP1A19 HP5C15 HP1B5A HP1B5A MAME HP1A6A HP4C10 HP1A10 HP2B5 HP3Al2 HP4Al2 HP5B6 HP1C5 HP5C14 HP2E16 HP3A7 HP1A8 HP4C12 HP1A13 HP2B7 HP3A18 HP4A15 HP581I HPIC9 HP5C13 HP2E17 HP4C8 HP1B4 HP4C17 HP1A15 HP2B8 HP384 HP4A17 HP5B12 HP1C14 HP3C18 HP188 HP4C18 HP1A17 HP2B9 HP385 HP484 HP5815 HP1D6 HP4A10 HP1811 HP4D17 HP183 HP2810 HP3B6 HP4B5 HP5818 HP1D14 HP4A11 HP1818 HP4E1 HP1B6 HP2811 HP3B7 HP4B6 HP5C2 HP1E13 HP4B10 HP1B19 HP4F1 HP169 HP2812 HP388 HP487 HP5C12 HP1E17 HP4C11 HP1C3 HP4F3 HP1B10 HP2B13 HP3B9 HP488 HP5C15 HP2C6 HP4D11 HP1C17 HP4F10 HP1812 HP2814 HP3B10 HP4811 HP5C19 HP2C14 HP5B10 HP1D1 HP4F11 HP1B13 HP2B15 HP3B11 HP4B12 HP5D1I HP2D6 HP2C18 HP1D7 HP4F14 HP1814 HP2816 HP3812 HP4B13 HP5DI2 HP209 HP1D16 HP4F16 HP1815 HP2B17 HP3816 HP4814 HP5E1 HP2014 HP1F1 HP5A5 HP1816 HP2818 HP3B17 HP4B15 HP5E2 HP3A14 HP1F1O HP5A9 HP1B17 HP2819 HP3B18 HP4B16 HP5E7 HP3A15 HP1F17 HP5A15 HP1C3 HP2C2 HP3819 HP4B17 HP5E10 HP381 HP2A4 HP5A16 HP1C8 HP2C8 HP3C3 HP4B18 HP5E11 HP3C6 HP2A9 HP5A17 HP1C12 HP2C11 HP3C8 HP4B19 HP5E12 HP3C9 HP2A15 HP5A18 HP1D11 HP2C12' HP3C11 HP4C3 HP5E13 HP3D6 HP2A19 HP5A19 HP1E1 HP2E2 HP3C12 HP4E2 HP5E17 HP286 HP5B5 HP1E2 HP2E3 HP3D2 HP4E3 HP5F6 HP3D14 HP2C3 HP588 HP1E3 HP2E4 HP3E1 HP4E4 HP5F11 HP3E2 HP2C17 HP5819 HP1E4 HP2E5 HP3E3 HP4E5 HP5F13 HP4C6 HP2D1 HP5C3 HP1E5 HP2E6 HP3E4 HP4E6 HP5F16 HP4C14 HP2F3 HP5C9 HP1E6 HP2E7 HP3E5 HP4E7 HP5813 HP4D6 HP2F7 HP5C17 HPIE8 HP2E8 HP3E6 HP4E8 HP409 HP2F9 HP5D3 HP1E11 HP2E9 HP3E7 HP4E9 HP4D14 HP2F16 HP5D15 HP1E14 HP2E10 HP3E8 HP4E10 HP4E16 HP3A3 HP5E3 HP1E15 HP2E11 HP3E9 HP4E11 HP5A3 HP3A19 HP5E5 HP1F3 HP2E12 HP3E10 HP4E12 HP584 HP3813 HP5E8 HP1F4 HP2E13 HP3E11 HP4E13 HP587 HP3B14 HP5E15 HPIFS HP2E14 HP3E12 HP4E14 HP5B9 HP3C2 HP5F1 HP1F6 HP2E15 HP3E13 HP4E15 HP5C6 HP3C17 HP5F4 HP1F7 HP2F1 HP3E14 HP4F5 HP5C14 HP3F9 HP5F8 HP1F12 HP2F2 HP3E15 HP4F7 HP5C18 HP3F10 HP5F17 HP1F12 HP2F5 HP3E16 HP4F13 HP5D6 HP3F11 HP5F18 HP1F14 HP2F12 HP3F1 HP4F17 HP5D9 HP3F16 HP2A3 HP2F14 HP3F3 HP5A4 HP5D14 HP3F17 HP2A6 HP2F15 HP3F6 HP5A7 HP5E4 HP4A19 HP2A9 HP3A4 HP3F14 HP5A10 HP5E6 HP483 HP489 HP2A13 HP2A17 HP3A7 HP3A8 HP4A4 HP4A6 HP5A1 HP5E9 HP5E14 j RE�1)Et7VEC SOUND ATTENUATOR (SA) SCHEDULE MARK NUMBER SA-1 LENGTH FEET 3 UNIT WIDTH X HEIGHT INCHFS 12x36 MAXIMUM PD IN /H20 .11 MAX FV FPM 550 AIR QUANTITY CFM 1650 RATING +1000 MINIMUM REQUIRED ACOUSTIC RATING dB RE 10-12 W 63 7 OCTAVE_BANND CEN R FREQUENCY IFRT7 125 250 1000 2000 12 16 28 35 35 4000 28 8000 17 REMARKS IAC TYPE S SA-2 3 12x24 .10 550 1000 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA-3 3 12x18 .10 550 750 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA-4 3 12x42 .11 600 2000 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA-5 3 6x24 .10 550 500 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA-6 3 12x12 .10 550 500 +1000 7 12 16 28 35 35 28 17 IAC TYPE S SA-7 3 6x12 .10 550 450 GATE +1000 SYR 7 12 16 REVISION 28 35 35 BY 28 APPROVED 17 GATE IAC TYPE S A RECORD DRAWINGS KLIR/DS 10.1.90 RECORD DRAWING SAZAN/SL 12.09.13 ID NUMBER EXAMPLE: HP2D16 NOTES: i1.1 460V/30/60Hz 2. 208V/30/60Hz 3. 115V/10 60Hz (4.) 208V/10/6DHz ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION 6 APPROVED ORMAN P. TRACEY ESECXED R. MURRAY GATE SHERRIE LE CONSTRUCTION NOTES C TRECEIVED ILA FOR GORE COMPLIANCE JAN 2 9 2018 '+ APPROVED FLOOtCOLUlLOCATION �I i1Yii� ,J FEB 01 2018 CENTER HEAT eUMP City of Tukwila BUILDING D ® DLR Group EQUIPMENT SCHEDULES 'CURRENT REVISION 33373-10 SHEET GATE 08.15.17 �HJ SV 908 1 LEGEND INSIDE WALL 6. 3 8'-0 5'-6 �� mow■ MARA; 1w1 k rairt rimm WIEN -NpPP- LIM —�—� I- 1/2" SRA ----. lei 81 APPROVED DOE SrM \1■ o I o 1 4 1/4 11 1/,1 1/20 1/2- 41 1/2 1 1/2 tin 1141-1 WWI LIM 1NUM PAM .111NIUM*130 00 HJ 1" 1 1/2 11/2 1 1/4 1/4 11/2 _ 11/4 CO 0 1/4 &Ali CO Iled`TliallialriMill 11111111111110 1 _ ■i • 4 11= 11=�■ Ni; ■■►= ■I■ 9 Pil uI 1.-mr 1-15 1ST FLOOR PLAN SCALE: 1/8"=1'-0" 61 061E A F22 WHITE ROOM RECONFIGURATION J/160652-00 M.WONG MW FOR RWS 02.16.07 r 7'-6 ACCEPTABILITY 1H6 DESIGN Nil/OR SPECFICAIKIN IS APPROVED DLR Group 1RUWN K.BUN C1Wt8RAH PATE 4.20.01 4.20.01 8 SOMME SPRINKLER HEAD , PENDENT IN UNE SPRINKLER HEAD, UPRIGHT — 6— AUTOMATIC SPRINKLER RISER HALON SYSTEM AUTOMATIC DISCHARGE STATION SPRINKLER HEAD. SIDEWALL, UPRIGHT GENERAL NOTES STR . " ON PROVIDE SPRINKLER GUARD AT EXISTING SPRINKLER HEAT) IN ELEVATGOR PIT. RECEIVED CITY OF TUKWILA JAN 2 9 2018 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED I FEB 01 2018 • City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION 08.15.17 FIRE PROTECTION 1ST FLOOR PLAN CURRENT REVISION 33373-10 STN1i0. B DATE 08.15.17 SKEET LEGEND SYM 0 _ T I .. I 50 ill ✓1 50 I, 413g1 1 200 200 ►1® 150 fie o►s 1:1 �� ' ' {� o 6 1011e..' in CD �IP2 u�I L!J ® _ �z9oD ►_� 50 KG I.. p' -{ 200 0 11/ 0 —p;J "to 0. 200 f1150 , ' 200 4,iI�•+S CD j, Aln 3 ►.4 p 1010� it' 1 MI/ 3e 200 200 0 2 %V 135 ME An C D 60 FD © u P nu An `� e 475 " '1 475 1=1 I•-1e / n 150 , %1 j : -1 u°F ►�1200 0150 Gil Al 1� 8/10' == `_I v 15; HP150 1 o�.lr �p i m 17 �C3 p 0 ! Q..�� . 12 _ 4 QT 3 I, ' 2900 2 FD 100 •� ...e �`l An © ,- FD t FD FD N ►3200 20t a� �, Z ' /1 315 Aick 315200 � ' V, �5 1212 16i' Q ©61 2200 ki ( m►T 29001_2 o m 2D4 m till Jk Pis 4 v �4 lav _ 0150 _a © ►� 60 ' - i P3 ' 315 0 Q,\ �I� a Ilrr� I;` ►7 100 I' 1 s v tall ►�i 200 DO ►1 10 10 � p // ■ 1! . , 6/10 rd 1 3 60 /aa ©315 �1:131i1. Rs n 4750 P a IL� Fm —��O i �ii� nn � IPIIRL- i i , v / .i v �t1 i �� �,,1 CAPPED , R1' 4 ,! �l�m3�. ' III ` !J % 120 4r1150 0 v ►� ►V 200 2 e ,1 _ H5'hAS 5 m 0 v ►�I Am 5B5 0 / I : 85 2 HP1 1 ' v ow ibi• o71 �� 60/24il ;� r'� I , _ E. 7500 10/10 ►_j 0 80 \,_�I ►_I Pat OI■ I, II 150 m150 m 1_ 20/16 k hn niyt LOU. "1 160 v 160 I� AFSD 1 11 111/ . I 0 11 1 (! y - 5 � Ili1mil 4 L� � AIX 10 0 ,I a�- 2 ,I All ®m1' : •114I, ' umWICI'r• 2725 ►_1150 I� I �t1 I / P%V r [�lu of 60 m,2 I ilw we F i t m= m ® 275 ►� F, ' aiik.V II FwKi15V vN iio P © !i 275 711 p ►�1150 , , 1.12 REVISION ue OPROVED are m REVISION FIFTH FLOOR HVAC PLAN rn WORRIED D1I A CAP ABANDONED DUCIWOR JIf757066-00 KGP RWS/EJC ACCEPTABILITY MS OESIIII ANt/OR SPECIFICATION IS APPROVED 2 REVIEWED FOR ODE COMPLIA APPROVED FEB 01 2018 City of Tukwila BUILDING DIVISION co 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 2 SYMBOL FOR GENERAL NOTES TYPICAL. ONSTRUCTION NOTES 24/36 MOTORIZED DAMPER. POWERED CLOSED. OPEN ON SIGNAL FROM FIRE ALARM SYSTEM PANEL PROVIDE 24 VAC CONTROL VOLTAGE TRANSFORMER AND CONNECT TO MOTORIZED OPERATOR. —RECEIVED OF TUKWILA JAW 2 9 2018 MIT CENTER DLR Group DRAWN M. CNJNIRS 10.01.64 R. MURRAY URRAY 10.01.04 SUET ME ISSUE FOR CONSTRUCTION 08.15.17 FIFTH FLOOR HVAC PLAN 'CURRENT REVISION 33373-10 sem B A KEY PLAN NO SCALE SVNBOL OATS E 08.15.17 RADON: 8/7/2017 10:5743 AN AIRSAN COMPACT SILENCER R/A GR REVISION 14/10 TITUS jTSMA-AA 24" X 24" 10°0/160 CFM (10 PLACES) Br a1E 24/16 20/16 AP 1^1Il�il n l�E 1031 150 ,! 150 AFSD ®■I 12 12 s 12 >f o00 TITUS jTSMA-AA 24" X 24" 10"0/300 CFM (2 PLACES) SD/ REVISION 300 AFSD 280 280 ABANDONED IN isj CE DUCT 10 10 (T' O 20/16 0/16 AFSD FIFTH FLOOR HVAC PLAN — B SCALE: 1 /8"=1-0 Err APPROVED DAZE A RECORD DRAWINGS WIC KMR/DS 10.01.90 E10: RELOCATE DCMA 4557325-02 AMONG RWS 01.16.06 24/16 X X 6 10 80 X PSE9 P3 ABANDONED IN PLACE DUCT X 10/10 ACCEPTABILITY M, twAAIE 1H6 DESIGN AND/OR SPELf1CATNIN IS APPROIED R WURR1Y co GENERAL NOTES 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE h LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 2. SYMBOL FOR CONSTRU Q T TYPICAL 24/36 MOTORIZED DAMPER. POWERED CLOSED. OPEN ON SIGNAL FROM FIRE ALARM SYSTEM PANEL PROVIDE 24 VAC CONTROL VOLTAGE TRANSFORMER AND CONNECT TO MOTORIZED OPERATOR. SECTION 1/8"=1'-0" RECEIVED CITY OF TUKWILA JAN292018 PERMIT CENTER LOCATE TO CLEAR DIAGONAL GRACING REVIEWED FOR CODE C 3)FEB . 11101.90 10.01.90 SueRnc City o BUILDIN 0s of iPLI KEY PLAN N0 SCALE IL DER Group +Oven use none., .rmrn CE ION FIFTH FLOOR HVAC PLAN - 1 51/12 LEGEND: EXISTWG WALLS NEW FULL -HEIGHT PARTITION DEMOUNTABLE PARTITION FURNISHED AND INSTALLED BY OWNER PROGRAM PERIMETERS AND STC 45 PARTITION STC 45 PARTITION STC 50 PARTITION ISSUE FOR CONSTRUCTION 08.15.17 OAFFOR REVSSON 33373-10 061E 08.15.17 RF ET RATION: 8/7/2017 10:59:57 AN SVIE I AIRSAN COMPACT SILENCER R/A GRILLE (TYP 4) REARM A I GAP AB/VMONED DUCTWORK 5M121M507 S NTSMA-AA 24" X 24" NECK/160 CFM EACH eJ► ire 400 445 H1STI3 400 T 150 Ham' BY J1757066-00 KGP APPROVED f 2500 DATE 5M121M507 20/12 500 150 TC M TCH LINE (FOR CONTINUATION SEE SHEET 5MI 16/12 44/16 60/24 AIRSAN COMPACT SILENCER R/A GRILLE (TYP 4) FIFTH FLOOR HVAC PLAN - A SCALE: 1/8"=1'-0" SYM G REPLACE HVAC UN IN ECC REASON O 0 11 150 2650 • 150 ,I Via► I0 - ■3'Im IC-1 TITUS •TSMA-AA 24" X 24" 511 3ER, 10"0 NECK (TYP 8) BY APPROVED DATE J1786060-OOI KGP I RWS/DOT 10.12.01 I I KEY PLAN NO start ASBESTOS NOTIFICATION teEdo. detn111•1 sold be ..r. FM.i�.6 ail 1 -YiT •d . iY4 la mood �Yr,�. • i�.4.1i. jib 200 150 CO N ABANDON IN PLACE AFSD 5M12,R LEGEND: EXISTING WALLS NEW FULL -HEIGHT PARTITION = DEMOUNTABLE PARTITION FURNISHED AND INSTALLED -IF-OWNER --- PROGRAM PERIMETERS AND STC 45 PARTITION STC 45 PARTITION --- STC 50 PAR11110N CAPPED FD 16/12 5M121 M520 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EOUIPMENT NUMBER FOR MAINTENANCE & LABEL. �--EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. 2. SYMBOL FOR TYPICAL. 24/36 MOTORIZED DAMPER. POWERED CLOSED. OPEN ON SIGNAL FROM FIRE ALARM SYSTEM PANEL. PROVIDE 24 VAC CONTROL VOLTAGE TRANSFORMER AND CONNECT TO MOTORIZED OPERATOR. ABANDON IN PLACE HP 5C1 44/16 AFSD2 50 30 L: MI In RECEIVED CITY OF TUKWILA JAN 2 9 2018 PERMIT CENTER 5/4 •`r 11-� WIPLIAILQ0 A ` PROVED 400 FEB 01 201 of Tukwii BUILDING DIVI ISSUE FOR CONSTRUCTION PARTIAL FIFTH FLOOR HVAC PLAN 08.15.17 ACCEPTABILITY 1H6 DESIGN AND/OR SPR]i1CATNIN 6 APPROWD M. CAUNMS �I 0190 SWORE R. MURRAYD R. MU10.01.90 SCALE: 1/4"=1"-0 FIFTH FLOOR HVAC PLAN DLR Group ICuRRENT RENSION SLEET 33373-10 • 50 26/16 AFSD 20/16 FD 16/12 40/� :8/16 AFSD AFSD 44/16 AL 5 PL SmBoi DATE 0 08.15.17 RATION: 8/7/2017 11:01:47 M1 1/2" CW DN 1/2" HW DN 2" SAN DN 11/2"V 4" RD 4" coF 5"RWI. ON 5"OFD DN 4"of0 4"RD 4" OfD 4" RD 0 0 WORK ROOM 2"V OFFICE CONDENSATE PUMP & PAN g5 CO HP1 W00% ROOM 0 OFFICE 3" HPWS 3° HPWR-,,,,, 2" HPWR 2" HPWS 3/4°PUMPED COND. DRAIN HP5B6 CO VIP2/ OPEN OFFICE SLOPE 4" RD 4" OFD MATCH UNE (FOR CONTINUATION SEE SHEET 5M62) STAIR 2"V OfRCF OFFICE [LEV /5 TELEPHONF ROOM OFFICE EXIT CO'g1D9" 1 /2" HPWS 1 /2_.ILlii•_ ELEVATOR LOBBY MECH. SHAFT ELECTRICAL JANITOR 3/4 CD U REFERENCE RFM10 FOR T1NUAT1 STORAGE 4"OFD 4"RD FIFTH FLOOR PIPING PLAN - C SCALE: 1/8"=1'-0" OFFICE WORK ROOM OFFICE OFFICF 1 1/2" HPWR 1 1/2" HPWS 7-3/4 CD OPEN 1 1/4" HP i 1/4" HP OFFICE 3/4" PUMPED COND. DRAIN 2" -IPWR 2° HPWS 1—I 4" SAN SEE SHT. 5M111 FOR CONT. 4" HPWS & HPWR UP TO AHRD7 OFFICE REM9ON BY APPROVED arc m.+ REVISION Br DATE A RECORD DRAWING MJC KMR/DS 10.01.90 OFFICE F1 OPEN OFFICF 2"HPWS 2"HPWR t�iiFSE4 OFFI0}1P3J CONDENSATE PLAN H ?3n HP1 I I OFFICE t-R NA4 1/2" ID OFFICE OFFICE CO OFFICE 4"RD 4"OFD 4"RD 4`OFD 5-OFD DN 5"RWL DN 4"oFD 4°RD TYPICAL HEAT PUMP SEE NOTE 3 DISCHARGE 3/4" CONDENSATE DRAIN INTO EXISTING DRAIN PAN. SLOPE AT 1% SINK (P-7) BOWL: SINGLE COMPARTMENT 21 X 15 1/4 X 10 INCHES DEEP INSIDE DIMENSIONS, 18-GAGE, TYPE 302 STAINLESS STEEL, WITH 20 INCH RIBBED DRAINBOARD, SELF RIMMING WITH UNDERCOATING. ELKAY MODEL ILGR-4322-L. TRIM: CHROME -PLATED BRASS SUPPLY 151TH SPOUT, WATER ECONOMY AERATOR, SINGLE LEVEL HANDLE; CHROME -PLATED 17-GAGE BRASS P-TRAP AND ARM WITH ESCUTCHEON; ELKAY MODEL LK-2432 FAUCET AND MODEL LK-99 SS DRAIN OUTLET AND STOPPER. GENERAL NOTES 1. TYPICAL HEAT PUMP NUMBERING SYSTEM: EOUSPMENT NUMBER FOR MAINTENANCE & LABEL EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. LEGEND: REVIEWED FOR EXISTING WALLS CODE COMPLIANCE NEW FULL -HEIGHT 'ARTlT10N APPROVED NTABLE PAOTTON FURNISHED AND WALLED FEB 01 2018 BY OWNER PROGRAM PERIMEIRS AND STC 45 PAR ON STC 45 PARTITION', STC 50 PART1110N1 City of Tukwila � I KEY PLAN 6 DLR Group BUILDING DIVISION RECEIVED CITY OF TUKWILA JAIL 2 9 2018 PERMIT CENTER ISSUE FOR CONSTRUCTION 08.15.17 ACCEPTABILITY 1i. _""lD1RAZAOEH 0#S OESK71 AND/OR � SFEdFCh71IM1 6 APPR(WEO R. MURRAY !DATE FIFTH FLOOR PIPING PLAN 33373-10 SHEET 08.15.17 RATION: 8/4/2017 411:21 rn 4"RWL ON 4'0FD DN 4' 0F0 4" RD REVISION 1/2" ID 4" RD 4" OFD 1 1/2" • COI 1 1/2" ID 3" HP# 3" HPWS DATE 1 1/2' ID DRAIN DN TO S. SINK IN TOILET RM SEE SHEET 5M111 I,I I, Ak1 1/2" ID >11 1/4",PWS N i T • HPWR L. HPWS HPWR 4" HPWR 4" HPWS STY 3" HPWR 3" HPWS 8" HPWS 8" HPWR 6"HPWS 6"HPWR 5M61 M524 3/4" PUMPED COND. DRAIN 3 HPWR 3"HPWS 0 4" HPWS TO AHRD7 HP3IRIM Miff\ 3/4" COND UP. REFERENCE REKI10 FOR CONT 0 0000 CO Hga9 �HP1% © SEE 1/4 SCALE SHAFT PLAN IN THIS SHa T W SEE SHT. TCH LIN€ (FOR CONI1NUATON SE SHEET 5M63) T T 3" HPWR 3" HPWS 1 1/4" HPWS 1 1/4" HPWS 6' HPWR 6" HPWS 1 1/2" ID 1" ID CO 4" SAN 12" CPAR UP 12" CTWS UP 1 1/4" HPWS 1 1/4" HPWR 1" CW UP • TO PENTHOUSE 2" VTR ray 4 SAN UP -I 4' SAN UP 2" VTR _ i'ID 4"SAN 1 1 1 n I'i; 61) FIFTH FLOOR PIPING PLAN - B MYRCNED DATE A RECORD DRANINC DW/MJC IOAR/DS 10.01.90 1 1/2" ID 4"RD 3— 4"OFD ice/ 1 1/2" ID CO H 6" HPWR HPWS TYPICAL HEAT SEE NOTE 3 IkLMrED-L 3/4" PUMPED COND. DRAIN CONDENSATE PUMP & PAN CONDENSATE UMP & PAN 6" RD 6" OFD 4" RD 4. OFD 4"RD 4"0FD 4"OFD DN 4"RWL DN 4"OFD 4"RD c9) 10 14 DLR Group GENERAL NOTES PROVIDE 1" TAPS FOR FUTURE CONNECTION WITH VALVES AND CAPS IN LOCATIONS SHOWN. 2. FOR EXACT LOCATION OF HP'S SEE SHEET 5M13. ALSO SEE SCHEDULE ON SHEET M4 FOR PIPE SIZES AND DETAILS AND TYP. M311 TYP. M521 3. SLOPE ALL ID PIPING 1/8" PER FT. IN THE DIRECTION OF FLOW. [>SEE SECURITY PIPE DETAILS ON SHEET M528. 5. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. SEE DETAIL 5M621 M523 12" HPWS UP 12" HPWS DN 8" HPWR DN 2" PW •Wnv" Npmn i® Nonry A.m., SA ACCEPTABILITY I�F..RAHAZ#OEH �1001.90 ME THIS OLSIGN AND/OR HWu SPEC1F1041I09 6 APPROVED R. MURRAY 10.01.90 IISCHARGE CONDENSATE INTO EXISTING PAN. SLOP AT 1% PARTIAL PLAN SCALE: 1 /4"=1"-0 RECEIVED CITY OF TUKWILA JAN 2 9 2018 PERMIT CENTER 12" CTWS / ft WED FO- E CO ViiPLIANC APPROVED FEB 01 2018 8" IPWS rePWR RD Of Tukwila» P FRIALMIG DIVISION {tE-Y-FLAN NO SCA1E ISSUE FOR CONSTRUCTION 08.15.17 FIFTH FLOOR PIPING PLAN OARENTRENSION 33373-10 SHEET SYMBOL C DATE 08.15.17 6/4/2017 4:53:47 PN 4"RD - 4"OFD 6"RWL DN 6"OFD DN 4" ROOF DRAIN 4" OVERFLOW DRAIN CO 17 P 6" 6" 3/4" PUMPED COND. DRAIN FOPS ' 3" HPWR- , 3" 4"HPWS UP TO AHU-2 4"HPWR UP TO AHU-2 1 1/2" ID 3/4" PUMPED COND. DRAIN 1 1/2' V 1/2" HW 1/2" CW 1"ID OFD RD CONDENSATE PAN & PUMP 4"OVER FLOW DRAIN 4"ROOF DRAIN 4: OFD ,e,,— 4 RD 7 �-{CO H�7 HP1 ' 1C0 1 1/2" ID CO • H HP1 1 8 P H,f5-511 H HA /4" COND DN N WALL. CONNECT TO SINK TAILPIECE 2" HPWR 2" HPWS 3/4" PUMPED COND. DRAIN 1 1/2" ID DN TO S.SINK IN TOILET RM SEE SHEET 5M111 1 1/2" SAN DN 1 1/2" ID 1 1/2" HPWR 1 1/2" HPWS 0 0 4" SAN SEE SHT. 5M111 F*" CONT. 3/4" PUMPED 1 1/2" ID SAN COND. DRAIN /M IT'H LINES OR CONTINUATION SE SHEET 5M61) 6 4" HPWR 4" HPWS 6"HPWR 6"HPWS 0 CO H4 2" HPWR 2" HPWS 2" HPWR 2" HPWS 1 cjI- H H- a 2" HPWR 2" HPWS H7 HP1 2" HPWR 2" HPWS 1/4" HPWR 1/4" HPWS -�T t-ICO H5 2 9 "ID HSi CO HP5F HIl7 HP1 7 ZCO 3/4" COND. 1 1 /2"ID UMPED DRAIN 4" OFD 4" RD 6" OFD DN 6" RWL DN 4"0FD 4"RD CO CO 4"ROOF DRAIN 4"OVER FLOW DRAIN TYPICAL HEAT PUMP SEE NOTE 3 REVISION A RECORD DRAWINGS APPROVED MW/MJC K11R/DS 10.01.90 Fff FIFTH FLOOR PIPING PLAN - A SCALE: 1/8"=1'-0" APPROVED DATE ACCEPTABILITY OR MSCOSIGN An/ DLR Group MAM (R. AIURRF. 1A�Y 10.01.90 CHECIFED � 0.01.90 SuRTME GENERAL NOTES 1 > PROVIDE 1" TAPS FOR FUTURE CONNECTION WITH VALVES AND CAPS IN LOCATIONS SHOWN. r—>SEE ROOF SHIELDING DETAIL ON SHEET RF1. 3. FOR EXACT LOCATION OF HP'S SEE SHEET 5M13. ALSO SEE SCHEDULE ON SHEET M4 FOR PIPE SIZES AND DETAILS AND 4. SLOPE ALL ID PIPING 1/8" PER FT. IN THE DIRECTION OF FLOW. 5. TYPICAL HEAT PUMP NUMBERING SYSTEM: EQUIPMENT NUMBER FOR MAINTENANCE & LABEL. EQUIPMENT SIZE. SEE SCHEDULE ON SHEET M4. RECEIVED CITY OF TUKWILA JAN 2 9 2018 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED FEB 01 2018 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION 8.15.17 FIFTH FLOOR PIPING PLAN I KEY PLAN No SCALE N CURRENT R 3E 73 3310 SIVABOtC wE 08.15.17 DATE 0 1 PU 1-9 a 1 �0-10 FIRE VALVE 1A908-5A I I 10'-0' t/2' PLUG (1W) Ni Ni •n •n N 1 Cv 1 O^ O^ 10' i1 1/2' PLUG (TYP) 1 1 1 1 -9 •0-10 1-9 1 2 •— 1-9 1 2 8 N^ 1 N 1 1-9 /n • • -0' 10'-010'-0' T N1 0 Nq No / / � n NN O 0 01 8 — CO /5' 0 1 CV /2 a; 1-9 1/2 •ln i N1 CV • /0 /a /a N ja N 0 N b -i 19_1 00 to .91210- 0 IT 1C Nm Nm NI -12'g 1.0 ID '1�g •0-10 NN NY NCV -10 •n 01 9 1/2 A CV 4'-0' 10 -0 No No c / ? / 1_71,r m • 1 1 CO CV N 1 ^ CV O 0 10 8'-0 •n CV I /1-9 � 0-10 0 1 i+, • 1-9 ' N `�1' 11_91 . i 1 0-9 4• 0-9, 0 9 -0 a� i•f1-4 0-9 b _ N°O : 0-10 3-9 0 0-10 1 N N , 10.-0' ve 10-0' N 0-10 0 01 i 1-9 - 0-10 N11 3 1 1/2' PL110 0-9 0-10 1-9 0-9 10'0' N N4CD • 11 N§ NI CV 2 CV Nm O 0 0 •:,- NCV N, •o 0 1 .11 CV 1 aP1/2U1C� 1/2 2-5 , 27 O rn 2 9- N 1 N^ 4 s'- 6' 2'-0 No -9 •- 0-101I;�\ 1 1-9 N N • m 1 0 1 •\ 1 0-10 3-9 00-9 0-10 0 r N; 8 m 1-6 -6 0'T N i 1 �N 0-9 • 0-9 •- N , t 9-6 vt- 9-6 / 4,_3• • No S ib 0 0 N8 o 10-0 ryit 9-6 I 0-9 411-10 N 1 i• � 0-9 CV 0- 0 0 0_ 10 No X I0 T;2 _ 1� � a 1412 2'CAP .(i X "-2TCAP 7< B 8 10-0 '►- 10-0 1 r 1 0-9 ' b-9 N o Mom 1 1 0-9 0-9 • 1-9 0-10 1 -9 0-10 N 0-10 0-10 1-1 1 1/2' PLUG -6 CO 0_0 I 0-10 .+.' ' 1-9 2' 1 1/2PLUG Sri REIRSOI 81 APIRO.'S]) DATE SY• 18.-0' RDIAa1 5TH FLOOR PLAN SCALE: 1/8"= 1'-0" err APPROVED DATE A E10: RELOCATE DENA Jj557325-02 M.WONG RWS 01.16.05 ACCEPTABILITY DLR Group Valuer/1 K.BUN TO 3.10.01 114S DESIGN AND/OR OtECIOTO SPECMEC1110N IS APPROVED C.HNIRNI 3.10.01 LEGEND: —o- -- SPRINKLER HEAD , PENDENT IN UNE SPRINKLER HEAD, UPRIGHT AUTOMATIC SPRINKLER RISER HALON SYSTEM AUTOMATIC DISCHARGE STATION SPRINKLER HEAD, SIDEWALL UPRIGHT GENERAL NOTES: REV CITY OE CEITUKWEDILA JAN292018 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 01 2018 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION 08.15.17 Sly MT CENTER KEY PLAN O SCALE: NONE FIRE PROTECTION 5TH FLOOR PLAN icuRRENT3REvs*"3373-10 s801 SRAM B OWE 08.15.17 RA71ON: B/7/2017 11:09:1a AM LEGEND: SYM n 18-0 7-0 Y l '11 iii i_i��.�i In-; NI 31 • I do a. ... :7, nimil III IIIII MI c m■1���■■M■111■-mani.I 0to: I� E�MI - — �O'' a m 64 MI .111111111711 19 it Ng? ERA it it fO B" DETAIL Y .■Ii��M1o■■ I IIII■I.111■■■■I = =- r ro8 A A 81 8 j08 i 8 o " ]K .■imim 1■■■IiIiIIII1ms e` ■!■1 fl 1 ., - =I�, - m■1���.0.■1'it■�...1—■p■1 01 RI�i1rri�111111r� ia11lI ._...,. - - 10-'.1111111I111 10-� r r���.''. T � �[ .■!m1•/Ilium' mII�=■■IG� _ X 6-0 8-0 10-0 4-0 6-0 1010= 0 •11r u!11 w ■i t iI "b 11H monsi �� o^o -mot x aIIUI-- " , o EN Om -ilI _si1 . �1mr ai "';r II 1 inImi �1� ��It__ iJiNN!I11 I El —y I.5 _ - 2 ■M r1111 ■�1!.Iliiil11MIM A Ni�IIMMOI �l� IMES= I' "� 1U1�1I11� x ■ U I I I� 11 • ... ^ - Ft' X imar iuiii - - - - 2 I � ' -]ii*.fi1 X Ida ■t x lag :==: Sze 1-6 I �I.���■IIEti'L1nsizra��I.■I n.� Mb ii s..e.1=. iiii ". 11•1111011 ix •11n 11rr 1' ____ 8 - ilia :H a IMAM" 'E- III X ■■I.�■■.II I.■I I.M i7 i7■IIMII PFi F.M1,1a7■1 111141ii IiilrE i11IIr1II1-1--i. r R , , i Ell II _. Eir lir-0 IIiiD INN n't� - wi .�I ■ill rIJININIIII.�■■M�II.IIIII r'q.'� �Gj Mom, -- . ... ■I rrfill I O 11111 !!�!I "� ❑ v .I.1EL I ■■IININNE:11-E V/1.■I NA � l, lli[-`!�Ir��!�t�iil r� 4 7-6 ..,,, • TO V1AVE 1908-58 AT NEMSOm BY APPROMZD DATE SYM REMSOI 5TH FLOOR PLAN SCALE: 1/8"=1'-0" Ert APPROVED DATE A INSTALL MIS IN JSF AREA JI785146 SLB RISS 12.03.98 F MODERNIZATION OF ELEVATORS 33373-10 CLN CLN 08.15.17 COL D/18 O ACCEPTABILITY THIS DESKN AN0/012 SPECIACAN N IS APPROVED DRAWN DATE t9ccran SUBTITLE SPRINKLER HEAD , PENDENT IN LINE SPRINKLER HEAD. UPRIGHT AUTOMATIC SPRINKLER RISER HALON SYSTEM AUTOMATIC DISCHARGE STATION SPRINKLER HEAD, SIDEWALL, UPRIGHT GENERAL NOTES: 1 SPRINKLER PIPE TO BE SCHEDULE 40 BLACK STEEL WITH BLACK CAST STEEL FITTINGS. 2 SPRINKLER HEAD TO BE 155' PENDENT WITH CHROME RECESSED ESCUTCHEON. CONSTRUCTION NOTES: RECEIVED CITY OF TUKWILA JAN 2 9 2018 !PERMIT CENTER • j REVIEWED FOR :� CODE COMPLIANCE A?PROVED. j FEB 01 2018 tallof Tukwila ++� +�• DIVISION ISSUE FOR CONSTRUCTION 08.15.17 FIRE PROTECTION KEY PLAN st .Nc it T NEHsaN 33373-10 9Err s1,30` DATE 08.15.17 5TH FLOOR PLAN SCALE: 1/8"=1'-0" F LEGEND: -0- GENERAL NOTES: SPRINKLER HEAD , PENDENT IN LINE SPRINKLER HEAD, UPRIGHT AUTOMATIC SPRINKLER RISER HALON SYSTEM AUTOMATIC DISCHARGE STATION SPRINKLER HEAD, SIDEWALL, UPRIGHT RECEIVED CITY OF TUKWILA JAN 29 2018 PER,I/,' 4 CENTER REVIEWED FOR CODE COMPLIANCE APPROVED FEB 01 20.18 City of Tukwila PAW DIVISION ISSUE FOR CONSTRUCTION 08.15.17 KEY PLAN wvr. POE 6f sPITOAD 6R SY MGM A JSF MIC VTC PROJECT J1701437-00 CFH ACCIPTABILAY 9®01I6* AID 6 _BUN 09—CO 6m011V rg—R9 � 5TH FLOOR FIRE PROTECTION PLAN ICE I6I86 18/18AD WACU-0 3/4" COND DRAIN DN. REFERENCE 5M62 FOR CONTINUATION m Ee `1 R 6 5M11,RFM10 M520 60/60 HPC1}5 <1 Vrzciq AHRClj 6"VTR 60/60 RD OFD 0/50 SEE DETAIL / 2 RFM10 M502 10"CTWS 8"CTWR 10"CTWS 8"CTWR RFM10 RFM10 SEE DETAIL RFM10 A521 RFM1 10" BUTTERFLY VALVE (3 PLS) 12"X10" ECCENTRIC RED PIPE FLAT ON TOP (3 PLS) ti 600 \—54x24 (BELOW) RFM10 M502 10 RFM10 M521 11 10" EQUAUZING U E 12" TEE 12"X10"R 10" BUTTE VALVE (3 FLY S) "E C8" CAP FOR FU =14" SAN DRAIN ('fal -, G- t �. `1d2CTWS-J' PLS) A 3/4" COND 'RAIN DN. REFERENCE 61 FOR CONTINUA11O1 WACU-Q2 8'CTWR 60/60 DAMPER 44/40 OPNG RFM101M524 HEAT AND v-10" CTWS 8 CTWR TAPE TRACE NSULATE (TYP) CAP FOR FUTURE CONDUIT ROUTING (REF) 10" 8"CTWR b 12'CTWS H8 4"FD 2" VENT THRU ROOF LI- 12" LATERAL (2 PLS) 8"CTWR 8"CTWR PIPE DOWN TO 5TH FLOOR SEE SHT. 5M62 PENTHOUSE MECHANICAL ROOM PLAN 1 /4"=1'-0" 8"CTWR NFHB 12-CMS H.B. 10"CTWS a ++- SECTION 1100 GPM FLOW CONTROL VALVE (2 PLS) 2I SUPPORT BEAM 12"X8" RED FLG (REF) �(4 PLS) 12"CTWR 12"X12"X8" TEE (2PLS) PIPE DOWN TO 5TH FLOOR SEE SHEET 5M62 A 1/4"=1'-0' 717 1 2 >—?13) SSE PENTHOUSE MECHANICAL ROOM PLAN BELOW PARTIAL ROOF PLAN 1/8"=1'-0" CONDUIT ROUTING (REF) RFM10 M502 CAP FOR FUTURE 12"X8" LR RED El RFM10 RFM10 SUPPLY AIR • TEMPERATURE & OCCUPANCY MULTI -FUNCTION CONTROLLER WITH EHERNET & MS/TP BACNET CAPABILITY BY UNIT MFGR. PROGRAMMABLE. 6"VTR s7 ECONOMIZER SECTION & CONTROL BY UNIT MFGR MP \ RA OUTDOOR TEMP SENSOR TO LOCKOUT COOLING. BY UNIT MFGR A • P L Y •L • :• SYM 01 APPROVED ATE 5YM REVISION BY *PROVED ATE RECORD ORMMNC TUC MAR/DS 10.1.90 60/60 MOTOR OPERATED DAMPER -44 RD AND CD RFM10 M502 RFM10 M502 5M11,RFM10 M520 60/60 SE DETAIL LEGEND RECEIVED CITY OF TUKWILA JAN292018 PERMIT CENTER RUN CONDITIONS - AUTOMATIC OPERATION: THE UNIT SHALL RUN CONTINUOUSLY TO MAINTAIN THE FOLLOWING SETPOINTS: • 78'F (ADJ.) COOLING SETPOINT FAN: THE FAN SHALL RUN ANYTIME THE UNIT IS COMMANDED TO RUN, UNLESS SHUTDOWN ON SAFETIES. COOLING: THE CONTROLLER SHALL MEASURE THE ZONE TEMPERATURE AND SEQUENCE THE ECONOMIZER AND COMPRESSOR STAGES TO MAINTAIN SETPOINT. PROVIDE ANTI -SHORT CYCLE CONTROL. ECONOMIZER SHALL ACT AS FIRST STAGE OF COOLING. WACU SEQUENCE OF OPERATIONS NO SCALE TYPICAL FOR WACU-1, -2, -3 see D oup "• VWne• -. 60/60 521 1 1 > 12> I8x18 AO GENERAL NOTES SEE SHEET RF-11 FOR SHEILDING DETAILS. O 2.6KW FAN FORCED UNIT HEATER WTH BUILT-IN THERMOSTAT, 277V/60HZ/10, CHROMALOX TYPE LUH OR APPROVED EQUAL. 3 NOT USED 4. ROOF PIPE PENETRATION SEE DETAILS ON SHEET RF-11. 5. ROOF DUCT PENETRATION SEE DETAILS ON SHEET M520. OF EQUIPMENT MOUNTING DETAILS ON SHT. S-22. CONSTRUCTION NOTES MOUNT BTM OF UNIT 12" ABV ELEVATOR MACHINE ROOM FLOOR. REFERENCE A500 FOR MOUNTING DETAILS. © ROUTE 3/4" CONDENSATE FROM BTM OF UNIT THRU WALL TO ELEVATOR MACHINE ROOM.. 3/4" CONDENSATE DN. REFERENCE 51.160 FOR CONTINUATION. 1 • 1 - 09-0.a: 09-1T-Mt 0. • 09-008-M330.DWG FEB 01 2018 Cih, Of Tlek9Arila EI S.11121I OI C NS R UCTION 8.15.17 ACCEPTABILITY ORS DE51f,la MID 0R SPECIRA1109 5 DRAWN CHECKED DATE 06.06.17 SINTME PARTIAL ROOF PLAN axa Da R Dsa+ 33373-10 sneer arc C 08.15.17 RATION: 8/4/2017 10:52:34 AM