HomeMy WebLinkAboutPermit PL18-0036 - AT&T - WIRELESS FACILITYAT&T UPGRADES/WA6647/I-51-405/LTE SC 1157200370 PARENT FILE PL18-0036 THIS FILE L18-0047 WIRELESS FACILITY/TYPE 1 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director August 15, 2018 NOTICE OF DECISION TO: Drew Parker, MasTec Network Solutions, (080 AT&T) Hampton heights LLLP King County Assessor, Accounting Division Agencies with Jurisdiction All Parties of Record This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. I. PROJECT INFORMATION Project File Number: L18-0047; PL18-0036 Applicant: Drew Parker, MasTec Network Solutions, (OBO AT&T) Type of Permit Applied for: Type 1 Wireless Facilities Permit Project Description: The applicant is proposing modifying the existing builidng mounted concealed wireless communications facility by removing three (3) panel antennas three (3) TMA, and six (6) diplexers and adding three (3) panel antennas, six (6) RRHs, one (1) DC5 Distribution Unit, one (1) fiber trunk, two (2) DC Trunks, one (1) 5c & 6c bCEM card, one (1) Raycap, one (1) Nokia FSM4, one (1) exhaust fan and one (1) intake louver. The project also qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which requires the City to approve any eligible facilities request for a modification of an existing tower or base station that does not substantially change the physical dimensions of such tower or base station. This proposal is not considered a substantial change under the Tukwila Municipal Code 18.58.200.7, and falls within the guidelines for an eligible facilities modification. Location: Parcel 1157200370- located at 5711 South 152nd Street, Tukwila WA, 98188 Associated Files: PL18-0036 Comprehensive Plan High Density Resedential (HDR) Designation/Zoning District: Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov II. DECISION SEPA Determination: The City SEPA Responsible Official has determined that this application does not require a SEPA threshold determination because it is categorically exempt. Decision on Substantive Permit: The Community Development Director has determined that the application for a Wireless Telecommunication Facility does comply with applicable City and state code requirements and has approved this application. III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code §18.104.010. Other land use applications related to this project may still be pending. No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the conditions which were imposed by the MDNS decision or the failure of the Department to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner. A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King County Superior Court from the Hearing Examiner's decision. IV. PROCEDURES AND TIME FOR APPEALING To appeal the Community Development Director decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this Decision. The requirements for such appeals are set forth in Tukwila Municipal Code Ch. 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing party's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. 5. . Appeal fee per the current fee schedule, additional hourly charges may apply. In addition, all hearing examiner costs will be passed through to the appellant. Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the Hearing Examiner based on the information presented to the Community Development Director, who made the original decision. No new evidence or testimony will be permitted during the appeal hearing. Parties will be allowed to present oral argument based on the information presented to the Community Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW Ch. 36.70C. An appeal challenging a DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the subject property. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Jonathan Joseph, who may be contacted at 206-431-3662 for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. 62_ Departm t of Community Development City of Tu ila /— Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director Staff Report PREPARED August 15th, 2018 NOTIFICATION: Notification is not required for a Type 1 land use application. FILE NUMBER: L18-0047; PL 18-0036 APPLICANT: Drew Parker, MasTec Network Solutions, (OBO AT&T) PROPERTY OWNER: Hampton heights LLLP REQUEST: Approval of a Type 1 Wireless Telecommunications Facilities Permit to modify the existing building mounted concealed wireless communications facility by removing three (3) panel antennas three (3) TMA, and six (6) diplexers and adding three (3) panel antennas, six (6) RRHs, one (1) DC5 Distribution Unit, one (1) fiber trunk, two (2) DC Trunks, one (1) 5c & 6c bCEM card, one (1) Raycap, one (1) Nokia FSM4, one (1) exhaust fan and one (1) intake louver. LOCATION: Parcel 1157200370- located at 5711 South 152nd Street, Tukwila WA, 98188 ASSOCIATED PERMITS: Electrical permits issued through the City of Tukwila will be required for service alteration for any other electrical service work that is anticipated but not noted on the plans, per article 85.12 (B), Washington electrical code. Building and mechanical permits are required for scope of work stated on the submitted plans. SEPA DETERMINATION: Exempt COMPREHENSIVE PLAN High Density Regional (HDR) DESIGNATION: ZONE DESIGNATION: STAFF: ATTACHMENTS: High Density Regional (HDR) Jonathan Joseph, Planning Intern Project Plans for Permit L18-0047 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Page 2 FINDINGS Vicinity/Site Information Project Description The applicant is proposing modifying the existing building mounted concealed wireless communications facility by removing three (3) panel antennas three (3) TMA, and six (6) diplexers and adding three (3) panel antennas, six (6) RRHs, one (1) DC5 Distribution Unit, one (1) fiber trunk, two (2) DC Trunks, one (1) 5c & 6c bCEM card, one (1) Raycap, one (1) Nokia FSM4, one (1) exhaust fan and one (1) intake louver. The project also qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which requires the City to approve any eligible facilities request for a modification of an existing tower or base station that does not substantially change the physical dimensions of such tower or base station. This proposal is not considered a substantial change under the Tukwila Municipal Code 18.58.200.7, and falls within the guidelines for an eligible facilities modification. Existing Development This telecommunications facility is preexisting. Surrounding Land Uses 5'2 5021 A101A1 .4 5821e21 • 02 A2 '3 610158 1 831,58a2 1i 203 B 104 Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Page 3 The property is zoned High Density Residential (HDR). Surrounding parcels are zoned within the HDR zone. South 152nd Street is to the north of this parcel, 57th Ave S is to the West and South 152nd Place is to the South of this parcel. Background In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.71) to the Zoning Code. The chapter provides location and design requirements for the placement of WCF within the City of Tukwila. In 2016 the city adopted amendments to this ordinance in compliance with the Federal Spectrum Act. Location Selection Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co - locations and utilizing existing structures are favored over the development of new standalone WCF within the City. TABLE.A Type of Perin t:'Rectulrod, Based one Type & Wireless Communication Facility Zoning(i) T' rt of Facility l estdentiaill Commercial trad!usirla1 Adding anbranas. to are wising tower or tidily Pole Type 101 Type 1V1' Type i+ Eigibl'e'lacilitiies ramification Type 11 Tye 11 Type 1 thility;pole co -location Type 2 Type 2. Type 2 Concealed balm attached Type 2+71 Type 2P1 Type I Non=concealed building, attached 'Type 20A1. Tye 2 Type 1 Neal. low .or height adjustment rat Type 301 Tye 3 Type 3 (1) Zoning for any private/public property or right-of-way Residential — LDR, MDR, or HDR Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS Industrial - LI, HI, MICA, or MIC/H (2) Provided the height of the tower does not increase and the square footage of the enclosure area does not increase. (3) An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.150. The applicant is proposing modifying the existing building mounted concealed wireless communications facility by removing three (3) panel antennas three (3) TMA, and six (6) diplexers and adding three (3) panel antennas, six (6) RRHs, one (1) DCS Distribution Unit, one (1) fiber trunk, two (2) DC Trunks, one (1) 5c & 6c bCEM card, one (1) Raycap, one (1) Nokia FSM4, one (1) exhaust fan and one (1) intake louver. Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Page 4 This site will be a modification to the property and falls within an Eligible Facilities Modification of the Tukwila Municipal Code. Per TMC 18.58.200.7C. Design Standards The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below indicates if the applicant's proposal complies with required standards. Table 1 (See TMC 18.58.070 for further details) General Requirements Project does comply Project does not comply Not Applicable Notes 1. Generators or other devices which will create noise must comply with TMC 8.22 regarding noise. x 2.Business License Requirement x 3.Only safety signage must be placed on the WCF. x 4. Accommodations for parking for maintenance personal must be provided. X This modification does not affect parking. , 5. Towers shall either maintain a galvanized steel finish or be painted a neutral color so as to reduce its visual obtrusiveness. x 6. The design of all buildings and ancillary structures shall use materials, colors, textures, screening, and landscaping that will blend the tower facilities to the natural setting and built environment. x 7. Antennas shall have the same color scheme as the structure they are located on. x 8. WCF poles and towers shall only have safety lights if required by a government agency. X ' Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Page 5 9. No advertising is permitted on WCF X No advertising is proposed. 10. Each service provider shall be limited to an equipment enclosure of 360 square feet. x Table 2 (See TMC 18.58.100 for further details) Concealed Building Mounted Development Requirements Project Does Comply Project Does Not Comply Not Applicable Notes 1. The proposed facility must meet the height requirements of the applicable zoning category x 2. Are antennas placed in "Rooftop Appurtenances" which includes: church spire, chimney or fake chimney, elevator tower, mechanical equipment room, or other similar appurtenances required to be placed on the roof, but not intended for human occupancy. x , , ; 3. Antennas must be concealed from view. x 4. If screening antennas, screens must be made of the same material and be the same x ' Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Page 6 color as the building. 5. Antennas hall be painted to match the color scheme, of the - building(s)/pole x 6. Feed lines and coaxial cables should be located below the parapet of the rooftop x , 7. Cabinet equipment is located within the building or on the rooftop x 8. If the equipment is cabinet located on the ground, a 6- foot-tall fence surrounds it x 9. If equipment cabinet is on rooftop, screening must be consistent with the existing building. x CONCLUSIONS 1. The proposed modifications to the existing WCF will not significantly alter the conditions that currently exist and will not be materially detrimental to the public welfare or injurious to property or improvements in the vicinity. 2. As demonstrated in Table 1, the project meets all applicable development standards for a Type 1 WCF. 3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian • circulation, building or site design. 4. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan. 5. The project also qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which ' requires the City to approve any eligible facilities request for a modification of an existing tower or base station that does not substantially change the physical dimensions of such tower or base station. Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Page 7 RECOMMENDATIONS The recommendation to the Director of Community Development is to approve this application for a Type 1 Wireless Telecommunications Facility permit. INFORMATIONAL ITEMS A City of Tukwila electrical permit is required for service alteration. A building and mechanical permit are required for the site work. Please note that the installation of an emergency power disconnect switch is required for Fire Department use. If this cannot be done, please provide a non -ionizing electromagnetic exposure levels report for Roof Top Modeling. Contact Don Tomaso at 206-971-8723 to get more information about permit requirements for the power disconnect switch or non -ionizing electromagnetic report. Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov June 13th, 2018 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Re: AT&T Wireless Site Number/Name: Site Address: Communication Facility Modification WA6647 —1-5 & 1-405 5711 S 152ND ST TUKWILA, WA 98188 6409A COVER LETTER / COMPLIANCE WITH TMC SECTION 18.58 Department of Community Development: •:vIasTec Network Solutions On behalf of New Cingular Wireless PCS, LLC (dba "AT&T") we are pleased to submit this request to modify AT&T's existing wireless communication site at the location referenced above. Proposal AT&T proposes to modify an existing unstaffed wireless communication facility. The existing facility is located on a rooftop located at 5711 S 152ND ST TUKWILA, WA 98188. The proposed modification is depicted below and also show on the accompanying construction drawings. • DECOM: EXISTING NOKIA ULTRASITE. • REMOVE: o (3) EXISTING PANEL ANTENNAS FROM POS 2, o (3) EXISTING TMAs FROM POS (2), o (6) EXISTING DIPLEXERS FROM POS 2. • INSTALL: o (3) PANEL ANTENNAS IN POS 2, o (6) RRHs IN POS 2, o (1) DC6 DISTRIBUTION UNIT, o (1) DC TO DC CONVERTOR W/ (4) CONVERTORS, o (1) FIBER TRUNK o (2) DC TRUNKS, o (1) 5C & 6C bCEM CARD, o (1) RAYCAP, o (1) NOKIA FSM4, o (1) EXHAUST FAN o (1) INTAKE LOUVER This proposal complies with Tukwila Municipal Code (TMC) Section 18.58 which regulates the placement, construction and modification of wireless communication facilities, in order to protect the health, safety and welfare of the public, while not unreasonably interfering with the development of the competitive wireless telecommunications marketplace in the City. This proposal is not consider a substantial change as defined by the FCC rules or TMC Section 18.58.200. RECEDED JUN 22 2018 Community Development Scope of Work The proposal qualifies as an Eligible Facilities Request for a minor modification under Section 6409a. A copy of the Federal Commission's 6409a rule is enclosed for your information. AT&T proposes the following minor modifications to this site. (Please note: all work will be performed wholly within the existing premises and utility easements; and the project otherwise complies with the site's original conditions of approval.) Component Federal Section 6409 Limits AT&T's Proposed Modification Increase height of original structure 10 feet or less No increase in height of existing equipment proposed. Antennas extending horizontally from edge of structure 6 feet or less Antennas extend less than 0 foot horizontally from edge of structure. Additional equipment cabinets 4 or fewer, with no cabinets larger than the existing cabinets No additional cabinets proposed. Excavation Excavation or deployment outside the current site. No excavation proposed for this scope of work. Concealment Proposal would defeat concealment elements of the eligible support structure. Proposal does not defeat concealment elements. FCC Shot Clock for Section 6409a Minor Modifications Based on a submittal intake appointment date/filing date of June 13th, 2018, the projected FCC deadline for a decision is August 13th, 2018. Our goal is to work with you to obtain approval of this minor modification earlier than the deadline. We will respond promptly to any requests for information you may have for our application. Please let us know how we can work with you to expedite the approval process. We look forward to working with you on this important project, which will significantly improve wireless telecommunication services in your community without requiring an additional site. Should you have any questions or require additional information, please do not hesitate to contact me. Sincerely, Drew ?al-1er Drew Parker, Zoning & Permitting Specialist 1351 E. Irving Park Road, Itasca, IL 60143 Office: 630-634-4932 Email: Drew.Parker@mastec.com MasTec Network Solutions 1000 Centregreen Way, Suite 300, Cary, NC 27513 Tel (919) 244-5207 MNSEngineering@mastec.com www.mastec.com •IvIasTec Network Solutions City of Tukwila, WA Building Department Re: Expired Engineering License on Engineering Documents Date: June 21st, 2018 Dear Sir/Madam, It has come to my attention that certain engineering documents that were stamped before my previous expiration date of 6/9/2018 were recently submitted to your office for approval after that date. As such, there is concern that my engineering license may have lapsed since that date and therefore the engineering documents are no longer valid. In order to address this situation the following solutions are being presented to your jurisdictional oversight for selection: A) Confirmation that my license is still valid by providing the documentation included in this letter. This includes a snapshot verification of the Washington Board of Professional Engineers website, photograph of my wall certificate and photograph of my wallet card. B) Resigning and sealing any of the documents in question that have been presented to you between the dates of 6/9/2018 and 6/21/2018 with the older expiration date listed. After discussing with your colleagues please let me know if Option A) or Option B) will satisfy your needs in terms of ensuring the engineering documents are meeting all of your requirements. Please do not hesitate to contact me directly for any additional questions or concerns regarding this matter. Warm regards, Raphael I. Mohamed, P.E., P. Eng. Senior Director of Engineering WA PE License No 42214 Digitally signed by Repluel Mohamed ON: DN•Raphool Mehemed. O.Repheel I. Raphael Moha ed SERIgINU --.. a Irvgg7 & 47yyg5id Date: 2016.08.21 22:35:25-0e'00' Expiration 6/9/2020 If this item has been digitally signed and sealed by Raphael 1. Mohamed, PE on 06/21/2018. RECEIVED Printed copies of this document are not considered signed and sealed and the signature must be verified on n electronic copies. JUN 2 Go18 Community Development 810Z/LZ/90 - Z abed 0 State of Washington (t1SJ I https//fortress.wa.gov/dot/dotprod/bpdLicenseQuery/IgsSearchResultsaspx kL Search BUSINESS & PROFESSIONAL LICENSES WAS ttRtrON S1AT IIEPARTNEABF LICENSING Search Results Your Search Criteria: License Type: Engineers Last Name: Mohamed First Name: Raphael Street Address: 6921 Palaver Lane City: Cary County: Alt Counties Click on a name below for more Information. Results 1 - 1 of 1: Take a autck Survey LNew Search Name: License Type` +: -_'�"c . ''._City".77 t{State.... Fs MOHAMED, RAPHAEL ISA Results 1 - 1 of 1: Professional Engineer Cary Information Current as of 06/21/2018 3:07AM Padflc Time New Search NC Active Use of lists of individuals provided on this site for commercial purposes is prohibited under Chapter 42.56 of the Revised Code of Washington. Horne I Pram 1 Other Licenses I Contact U, I Copyright ID 2018 oot e 41 • • NDSIII k I RI IN1 rilE KO NRIF OF RI I k kii(PS 1,4', PRI I{ \ \i1;1\ I.} Rs '.IIIN\\Ds, U\FflW N .2., {I ‘‘)\\11 \ I \I I \•()Ns A D(,( IDEL•Es ),•1 rROF1 ‘...los iI 'R kI i( iJ 4 STATE OF }% ASHINGTON PRI /FISSIONAL. F•1.1•11_1( CIV11 o111(.0,1124•1,•11\11 111 (FRS} SERS'ItES ONES IS HI }slif111.1 IR o's11.1 11 •1 1 vl 4,1 F ( MORI% SOI I 111111, )S( 04110 ttl 1,1 1101111.11 1.1•11( • l`,•11\1 1 NM NF1P1) SIGS ATI RES 49211•41. xx F L (041 2'519 •I f() k‘S11 \" ))4 in SIENT DE ALISf. WITH •I Ft IF f I \JAI 11 k Is. Wlili II I ID I LACK COSIpETE'SCE: FIN 42214 06/(19'2020 I 1 F SI'l RII F OR IuVSI ( II PLAN OR tc, Pa I* 101( \II • 1 •111 l'Ff I* AR, 11INDFRI HEIR SI PERS IMIRN vs I Ft, II o.9nr_rntr-441.7.)741)(t, 1t19,19,-. 419471-rW46....9.11. "-LT, vrt. x-x,4111", ' 1:'••=1.:111e'1111-1.1.M41x.., —.4419,41,yt))64"60} 494z.9, STATE OF WASHINGTON :11F)6) f•,), . •,. ')NL) 194( 114SY()\(11X1S6 )1, THIS CERTIFIES THAT Dif Pt RV" OR fit 'SINESS NAMED BELOW IS AUTHORIZED AS A PROELtisioN AA Fs( ;INFER CIVIL MASTEC I4 OR k SOLUTI)NS, INC. RAPHAEL IS s MOH AM D OH I PALAVER 1 A CARY NC 21fzi9 42214 1 alms," ,4664, Page 3 - 06/21/2018 11/1.5/2005 06,0910211 6,4,9 (199 lunorst,^ th 1.10.-.91mvo �Idfrs JUN 22 2013 Community 0Development CITY OF TUKWILA Deportment of Community Development 6300 Soulhcenier Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY STATE OF WASHINGTON ss COUNTY OF KING The undersigned being duly sworn and upon oath states as follows: 1. I am the current owner of the property which is the subject of this application. 2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my knowledge. 3. The application is being submitted with my knowledge and consent. 4. Owner grants the City its em to ees a ants engineers, contractors or other representatives the right to enter upon Owner's real property, located at 711 Sp1 S2Nb�ST tUKWILA, WA 98188 / 1157200370 for the purpose of application review, for the limited time necessary to complete that purpose. 5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City. 6. Non -responsiveness to a City infomtation request for ninety (90) or more days, shall be cause to cancel the application(s) without refund of fees. EXECUTED at Itasca (city) IL (state), on Drew Parker June 13th ,2018 (Print Name) 1351 E. Irving Park Road Itasca IL. 60143 (Address) 630-634-4932 / drew.parker@mastec.com (Phone Number) (Signature) • On this day personally appeared before me g- LJ PARKE1( to me known to be the individual who executed the foregoing instrument and acknowledged that he/she signed the same as his/her voluntary act and deed for the uses and purposes mentioned therein. SUBSCRIBED AND SWORN TO BEFORE ME ON THIS 3 771 a Y OF �� , 20 OFFICIAL SEAL KENNETH J KWASNIK NOTARY PUBUC • STATE OF R.UNOIS MY COMMISSION EVIRESO6I01121 NO ' Y PUBLIC in an the State of 31i.mjot5 residing at revCnuN rY My Commission expires on SIQR/21-)1 W:1E'.SHAREPOINT FOLDER RESTRUCTUREtRererence\APPL1CA11ONS - Lend the App. & Hendows'CURRENT LAND USE APPLICA110NS1DRAFT Wirelnis Commune Lion Facility.docs i. L t J V JUN 22 2018 Community Development • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 WIRELESS TELE- COMMUNICATION FACILITIES APPLICATION FOR STAFF USE ONLY Planner: File Number: L i 8/ -- Q 0 9' 7 Application Complete Date: Project File Number: p j r 1)0'3 Application Incomplete Date: Other File Numbers: NAME OF PROJECT/DEVELOPMENT: AT&T Upgrades/WA6647/I-5I-405/LTE 5C BRIEF DESCRIPTION OF PROJECT: AT&T equipment upgrades on existing rooftop cell site. CIRCLE TYPE : TYPE 2 TYPE 3 Public Hearing Notices and Hearing Examiner Fees Apply. LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. 5711 S 152ND ST TUKWILA, WA 98188 LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). 1157200370 DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent. Name: Drew Parker Address: 1351 E. Irving Park Road Itasca IL. 60143 Phone: 630-634-4932 E-mail: drew.parker@mastec.com Signature: 1/4D'GW Tv-ke? Date: 06/13/2018 RECEIVED WAC1SHAREPOINT FOLDER RESTRUCTUREIReferenceAPPLICATIONS - Land Use Apps & Handouts CURRENT LAND USE APPLICAT1ONScDRAFr Wireless Communication Fecility.docx JUN 22 2018 Community Development COMPLETE APPLICATION CHECKLIST The materials listed below must be submitted with your application. You may request a waiver from items on the checklist that are not applicable to your project. Please discuss this waiver request with City staff either at a pre - application meeting or at the time of application submittal. Application review will not begin until it is determined to be complete. Within 28 days of receiving your application, City staff will determine if it is complete based on the attached checklist. If not complete City staff will mail you a letter outlining what additional information is needed. If you do not submit requested materials within 90 days from the City's request for additional information the City may cancel your application. Check items submitted with application Information Required. - Additional materials may be required APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities. x 1. Application Checklist (1 copy) indicating items submitted with application. x 2. Completed Application Form and drawings (5 copies). 3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site map, architectural elevations, method of attachment, proposed screening, location of proposed antennas, and all other information which accurately depicts the proposed project. Minimum size is 8 1/2" x I 1". Plans shall be no greater than24" x 36". x 4. Application Fee: See Land Use Fec Schedule. x 5: Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property (1 copy attached). N/A 6. SEPA Environmental Checklist. SEPA is not required when the facility: i) Is a microcell and is to be attached to an existing structure that is not a residence or school and does not contain a residence or a school; ii) Includes personal wireless antennas, other than a microcell, and is to be attached to an existing structure (that may be an existing tower) that is not a residence or school and does not contain a residence or school, and the existing structure to which it is to be attached is located in a commercial, industrial, manufacturing, forest or'agriculture zone; or iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a commercial, industrial, manufacturing, forest, or agricultural zone. x-6409a Cover Letter 7. A letter from the applicant describing the proposed project and describing compliance with the City's Code requirements stated in TMC Section 18.58. Include statement whether the proposal is considered a "substantial change" or not as defined by the FCC rules and TMC Section 18.58.200. N/A 8. Sensitive Area studies and proposed mitigation (if required). N/A 9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating compliance with TMC Section 8.22, "Noise". If the application requires a Type 2 review these additional items are needed: 10. Four sets of photo simulations that depict the existing and proposed view of the proposed facility; 11. Materials board for the screening material; 12. Landscaping plan; 13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal requirements for allowed emissions; 14. If the facility is located within a residential zone, a report from a radio frequency engineer explaining the need for the proposed wireless communication facility at that location. Additionally, n A@ & WSHAREPOINT FOLDER RESTRUCTUREsReferencOAPPLICATIONS . Land Use AppsHnndoutsTURRENT LAND USE APPLICATIONSORQFTIVae warp t)nicaLo Feeitity.doc, JUN 22 201B Community Development Know what's below Call before you dig. BUILDING CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT CONDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: JURISDICTION: CITY OF TUKWILA 2015 INTERNATIONAL BUILDING CODE 2014 NATIONAL ELECTRIC CODE TIA-222—G OR LATEST EDITION PROJECT INFORMATION PROJECTION DESCRIPTION DECOM: — EXISTING NOKIA REMOVE: —(3) EXISTING — (3) EXISTING — (6) EXISTING ULTRASITE PANEL ANTENNAS FROM POSITION 2 (1 PER SECTOR) TMAs FROM POSITION 2 (1 PER SECTOR) DIPLEXERS FROM POSITION 2 (2 PER SECTOR) INSTALL: — (3) PROPOSED — (6) PROPOSED — (1) PROPOSED — (1) PROPOSED — (1) PROPOSED — (1) PROPOSED —(1) PROPOSED — (1) PROPOSED — (1) PROPOSED PANEL ANTENNAS IN POSITION 2 (1 PER SECTOR) RRHs IN POSITION 2 (2 PER SECTOR) DC6 DISTRIBUTION UNIT DC TO DC CONVERTOR W/ (4) PROPOSED CONVERTORS IN EXISTING PURCELL FIBER TRUNK & (2) PROPOSED DC TRUNKS 5C & 6C bCEM CARD IN EXISTING PURCELL CABINET RAYCAP IN EXISTING PURCELL CABINET NOKIA FSM4 IN EXISTING PURCELL CABINET EXHAUST FAN & (1) PROPOSED INTAKE LOUVER PACF_N.UMRFP• MRWOR027599/MRWOR027506 PTN NUMBER* 3801AOBCZC/3901AOBDBR APPLICANT' AT&T MOBILITY RTC BUILDING 3 16221 NE 72ND WAY REDMOND, WA 98052 SITE LOCATION (BASED ON NAD 831- LATITUDE: 4T 27' 57.888" N (47.46608) LONGITUDE: 122' 15' 44.496" W (-122.26236) TOP OF STRUCTURE AGL: ±60' GENERA' INFORMATIQ$ 1. TRAFFIC IS UNAFFECTED. REDS VFRSION• V 3.00 DATED 10/20/17 SITE ACQUISITION' MASTEC CONTACT: TBD PH: TBD EMAIL: TBD CONSTRUCTION MANAGER: MASTEC CONTACT: DAN KELLY PHONE: (253) 579-3503 EMAIL: DANIEL.KELLY.COMOMASTEC.COM PERMITTING* MASTEC CONTACT: TBD PH: TBD EMAIL: TBD AT&T PROJECT MANAGER: CONTACT: TBD EMAIL: TBD PHONE: TBD CONTACT INFORMATION ENGINEER: CONTACT: PHONE: GPD GROUP PROFESSIONAL CORPORATION 520 SOUTH MAIN STREET, SUITE 2531 AKRON, OHIO 44319 JAMES GRANT (330) 572-2100 1-5 & 1-405 WA6647 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE 5C+6C PACE: MRWOR027599 LOCAL MAP e 9 t; ukwsa Garde, Loartmenta Foxe+ Creak Apartments 0 0 y,TE .k Newport Help . Apartments 8 • s Ma S 5outheanter View $ IU}MA tl Condominium V Ls Vista Apartments 9 r i. r 4e.. , a 152 dPi y_ y� J9 6. PyrxlVd Pointe v°'•w., ApMmems 4 '..n� Sounicenrar Nd u • Nunt,11Yl Apanowiee ` �' ARCO — — "440 0 Nc NO SCALE DRIVING DIRECTIONS _ DIRECTIONS FROM SEATTLE—TACOMA AIRPORT: HEAD SOUTHEAST ON AIRPORT EXPRESSWAY TOWARD DEPARTURES DR 56 FT, USE THE LEFT LANE TO KEEP LEFT 0.1 MI, KEEP LEFT 2 MIN (0.5 MI), CONTINUE ON AIRPORT EXPRESSWAY. TAKE WA-518 E AND 51ST AVE S TO S 144TH ST IN TUKWILA 5 MIN (3.0 MI), SLIGHT LEFT ONTO AIRPORT EXPRESSWAY 0.8 MI, KEEP RIGHT AT THE FORK, FOLLOW SIGNS FOR WA-518 E/INTERSTATE 5/INTERSTATE 405 AND MERGE ONTO WA-518 E 1.3 MI, TAKE THE 51ST AVENUE S EXIT 0.2 MI, TURN LEFT ONTO 51ST AVE S 0.8 MI, TAKE MACADAM RD S TO YOUR DESTINATION 3 MIN (0.9 MI), TURN RIGHT ONTO S 144TH ST 0.1 MI, TURN RIGHT ONTO MACADAM RD S 0.5 MI, TURN LEFT ONTO S 152ND ST, RESTRICTED USAGE ROAD 0.2 MI, TURN RIGHT RESTRICTED USAGE ROAD 197 FT PROr i7.!ETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. at&t mobility DRAWING INDEX SHEET NO: SHEET TITLE T-1 TITLE SHEET GN-1 LEGENDS, ABBREVIATIONS & CONSTRUCTION INSPECTIONS GN-2 GENERAL NOTES C-1 OVERALL SITE PLAN C-2 COMPOUND PLAN & EQUIPMENT LAYOUT C-3 TOWER ELEVATION & NOTES RF-1 ANTENNA CONFIGURATION RF-2 ANTENNA & RRH DETAILS RF-3 EQUIPMENT DETAILS E-1 GROUNDING DETAILS E-2 ELECTRICAL NOTES APPROVAL DATE SIGNATURE APPROVAL DATE SIGNATURE RF ENGINEER: LANDLORD. RF MANAGER: SITE ACQUISITION: OPPS MANAGER: ZONING AGENT: CONSTR. MANAGER: PROJECT MANAGER: NSB MANAGER: CONSTR. MANAGER: TRANSPORT: EQUIP. ENGINEER: COMPLIANCE: REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED 11"x17" PLOT WILL BE HALF SCALE UNLESS OTHERWISE NOTED GENERAL NOTES THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED. CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME ats�t mobility =eMasTec Network Solutions GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 PROJECT NO: 2018723.04.75142.01 DRAWN BY: CJM CHECKED BY: JG 0 05/21/18 ISSUED FOR CONSTRUCTION B REVIEW ��lT WOO 6�t(ED ` EW 1 Z' cli NVA1S// •t�(�i IRES 04/16/2020 IT 15 A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 1-5 & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE - ROOFTOP SHEET TITLE TITLE SHEET SHEET NUMBER -T-1 w EXOTHERMIC CONNECTION MECHANICAL CONNECTION CHEMICAL ELECTROLYTIC GROUNDING SYSTEM TEST CHEMICAL ELECTROLYTIC GROUNDING SYSTEM EXOTHERMIC WITH INSPECTION SLEEVE GROUNDING BAR c:=:=:= GROUND ROD IIF TEST GROUND ROD WITH INSPECTION SLEEVE 11FpT SINGLE POLE SWITCH DUPLEX RECEPTACLE CI) DUPLEX GFCI RECEPTACLE ��! FLUORESCENT LIGHTING FIXTURE r (2) TWO LAMPS 48-T8 1 L SMOKE DETECTION (DC) SD rn • ■ 9 8 T ❑• D 1 F 1 j AB ANCHOR BOLT INT INTERIOR ABV ABOVE LB(S) POUND(S) AC ALTERNATING CURRENT LF UNEAR FEET ADDL ADDIRONAL MAS MASONRY AFF ABOVE FINISHED FLOOR MAX MAXIMUM GRADE MBMACHINE BOLT AFC ABOVEINTERRUPTION AIC AMPERAGE INTERRUPTION CAPACITY MECH MECHANICAL ALUM ALUMINUM MFR MANUFACTURER ALT ANT ANTENNA MGB MASTER GROUND BAR MIN MINIMUM APPROX APPROXIMATE MISC MISCELLANEOUS ARCH ARCMRECTURAL MTL METAL ATS AUTOMATIC TRANSFER SWITCH MTS MANUAL TRANSFER SWITCH AWG AMERICAN WIRE GAUGE MW MICROWAVE BATT BATTERY (N) NEW BLOC BUILDING NEC NATIONAL ELECTRIC CODE BLK BLOCK NO.(#) NUMBER BLKG BLOCKING NTS NOT TO SCALE BM BEAM BTC BARE TINNED COPPER CONDUCTOR OC ON CENTER BOF BOTTOM OF FOOTING OPNG OPENING CAB CABINET (P) PROPOSED• P/C PRECAST CONCRETE CANT CANTILEVERED CEC CAUFORNIA ELECTRIC CODE PCS PERSONAL COMMUNICATION SERVICES CHG CHARGING PCU PRIMARY CONTROL UNIT CLG CEILING PRC PRIMARY RADIO CABINET CLR CLEAR PP POLARIZING PRESERVING COL COLUMN PSF POUNDS PER SQUARE FOOT COMM COMMON PSI POUNDS PER SQUARE INCH CONC CONCRETE PT PRESSURE TREATED CONSTR CONSTRUCTION PWR POWER CABINET DBL DOUBLE Qtt QUANTITY DC DIRECT CURRENT RAD RADIUS DEPT DEPARTMENT RECT RECTIFIER DF DOUGLAS FIR REF REFERENCE DIA DIAMETER REINF REINFORCEMENT DIAL DIAGONAL REO'D REQUIRED DIM DIMENSION RET REMOTE ELECTRIC TILT DWG DRAWING RMC RIGID METALLIC CONDUIT DWL DOWEL RRH REMOTE RADIO HEAD (E) EXISTING RRU - REMOTE RADIO UNIT EA EACH RWY RACEWAY EC ELECTRICAL CONDUCTOR SCH SCHEDULE EL ELEVATION SHT SHEET ELEC ELECTRICAL SIAD SMART INTEGRATED DEVICE EMT ELECTRICAL METALLIC TUBING SIM SIMILAR • ENG ENGINEER SPEC SPECIFICATION EO EOUAL SO SQUARE EXP EXPANSION SS STAINLESS STEEL EXT EXTERIOR STD STANDARD FAB FABRICATION STL STEEL FF FINISH FLOOR STRUCT STRUCTURAL FG FINISH GRADE TEMP TEMPORARYIL FIF FACILITY INTERFACE FRAME THK THICKNESS FIN FINISH(ED) TMA TOWER MOUNTED AMPLIFIER FLR FLOOR TN TOE NAIL TOA TOP OF ANTENNA FDN FOUNDATION FOC FACE OF CONCRETE TOC TOP OF CURB TOF TOP OF FOUNDATION FOM FACE OF MASONRY FOS FACE OF STUD TOP TOP OF PLATE (PARAPET) FOW FACE OF WALL TOS TOP OF STEEL FS FINISH SURFACE TOW TOP OF WALL FT FOOT TVSS TRANSIENT VOLTAGE SUPPRESSION SYSTEM FTG FOOTING TYP TYPICAL GA GAUGE UG UNDERGROUND GEN GENERATOR UL UNDERWRITERS LABORATORY GFCI GROUND FAULT CIRCUIT INTERRUPTER UNO UNLESS NOTED OTHERWISE GLB GLUE LAMINATED BEAM UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS GLV GALVANIZED SToILM GPS GLOBAL POSITIONING SYSTEM UPS UNITERRUPTIBLE POWER SYSTEM GND GROUND (DC POWER PLANT) GSM GLOBAL STSItM FOR MOBILE VIF VERIFIED IN FIELD HDR HEADER W WIDE HGR HANGER W/ WITH HVAC HEAT/VENTILATION/AIR CONDITIONING WD WOOD HT HEIGHT W.P. WORK POINT IGR INTERIOR GROUND RING WP WEATHERPROOF IN INCH wT WEIGHT . E x I 1 ,' JUN 22 2018 Community Development �, �� mobility elf a sTe Network Solutions c .- GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax05722102 A EMERGENCY LIGHTING (DC) 8 S SECURITY LIGHT W/PHOTOCELL LITHONIA ALXW LED-1-25A400/51K-SR4-120-PE-DDBTXD1 1 CHAINLINK FENCE —•—•—•—•—•—•—•—•—•— WOOD/WROUGHT IRON FENCE o 0 0 0- o 0 0 0 0 0 0o PROJECT NO: 2018723.04.75142.01 WALL STRUCTURE Y//////////////////////////////////1 LEASE AREA PROPERTY LINE (PL)— - - — - - — - - — - - — - - — - - — - - — SETBACKS LTA ATATA ��AM A AMAMAM A AVA A A �� DRAWN BY: CJM CHECKED BY: JG ICE BRIDGE ��i�vooo rATAvoAWA�ii�iA A iwAvAvAoAwAvoAvoivi oo _________ __ ____ _____ _ _ • • • • • • • • • • _ .............................. CABLE TRAY ................................ WATER LINE -•—*—•—•—•—•—*—•—•—•- 0 05/21/18 ISSUED FOR ca+sllucnoN 8 03/22/18 ISSUED FOR REVIEW UNDERGROUND POWER ♦ AA' • 'n UNDERGROUND TELCO - 1.1 Mt - - m OVERHEAD POWER —u• _—d•—w—w—o.—a.— v )w' S '1'. V ' .yw v NN A. ji .N�j O G.(,J ,. S',CQ! T ^, '! - 9 ti i i I S F� ► / �'�"'= �,�� ++'> ti1 �. ,, 1. 1 ' ?,St 1 ��' .. OFn C�;1S 1-[� A, `SJ I TJ� �w c � • �:. ���'�i'�1 •5�22�1 E r. S OVERHEAD TELCO UNDERGROUND TELCO/POWER----��*--un?-u�.-�?-�- ABOVE GROUND POWER—•�—a—•s—•s—•s—n—•s—e—•�—•�—•�— ABOVE GROUND TELCO —•�— —•a——•�—•�— — — — —•�— ABOVE GROUND TELCO/POWER - *Op -'•T�' -1p & -1O,P -1V, -1V. -10'/, -..V. -1./. - WORKPOINT W.P. ' SECTION REFERENCE ® DETAIL ® FxPIRES 04/ 16/2020 F REFERENCE IT IS A VIOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A TO ALTERTHISPROFESSIONAL �CINEER, UCENSED • 1-5 & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE — ROOFTOP J SHEET TITLE LEGENDS, ABBREVIATIONS & CONSTRUCTION INSPECTIONS _ - -- SHEET NUMBER GN-1 LEGEND 1 ABBREVIATIONS 2 NOT USED 3 fiENERAL CONSTRUCTION 1. FOR THE PURPOSE OF CONSTRUCTION DRAWINGS. THE FOLLOWING DEFINITIONS SHALL APPLY: GENERAL CONTRACTOR - MASTEC CONTRACTOR: (CONSTRUCTION) OWNER - AT&T ENGINEER - GPD GROUP 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND AT&T PROJECT SPECIFICATIONS. 3. GENERAL CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 4. AU. MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPUCABLE CODES, REGULATIONS. AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS. ORDINANCES. RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 6. UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS. EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTUNE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE. IT IS CRITICAL TO FIELD VERIFY DIMENSIONS. SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ENGINEER PRIOR TO PROCEEDING WITH WORK. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE ENGINEER PRIOR TO PROCEEDING. 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE UKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFIRM TO ALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION. 11. GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTMTIES WITH OTHER DISCIPUNES. 12. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER 8Y COMPETENT EXPERIENCED WORKMAN IN ACCORDANCE WITH APPUCABLE CODES AND THE BEST ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY LOCAL JURISDICTION. CONTRACTOR SHALL KEEP AREA CLEAN. HAZARD FREE, AND DISPOSE OF ALL DEBRIS. 14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY UGHT SHADED LINES AND NOTES. THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. 15. CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 16. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS. CURBS. LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 17. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND CONTRACTORS TO THE SITE AND/OR BUILDING. 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 20. THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL REVISIONS. ADDENDA. AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. 21. THE GENERAL CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2-A OT 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION. 22. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ENGINEER. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS SHALL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION. B) CONFINED SPACE, C) ELECTRICAL SAFETY, AND D) TRENCHING & EXCAVATION. 23. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED, PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK. AS DIRECTED BY THE RESPONSIBLE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 24. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED 8Y THE TOWER, EQUIPMENT OR DRIVEWAY. SHALL BE GRADED TO A UNIFORM SLOPE. AND STABIUZED TO PREVENT EROSION. 25. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION. SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. 26. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUNDING. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 27. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED TO 95 PERCENT STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL PRE -APPROVED BY THE LOCAL JURISDICTION. 28. ALL NECESSARY RUBBISH, STUMPS. DEBRIS, STICKS, STONES. AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. 29. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS. CATALOGS. SHOP DRAWINGS, AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR AT COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT. 30. CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS -BUILT REDUNES TO THE GENERAL CONTRACTOR UPON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. 31. CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. 32. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE, AND IS NOT FOR HUMAN HABITAT (NO HANDICAP ACCESS REQUIRED). 33. OCCUPANCY IS UNITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH. BY AT&T TECHNICIANS. 34. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED. 35. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST REVISION AT&T MOBIUTY GROUNDING STANDARD "TECHNICAL SPECIFICATION FOR CONSTRUCTION OF GSM/GPRS WIRELESS SITES" AND "TECHNICAL SPECIFICATION FOR FACILITY GROUNDING". IN CASE OF A CONFLICT BETWEEN THE CONSTRUCTION SPECIFICATION AND THE DRAWINGS, THE DRAWINGS SHALL GOVERN. 36. CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REOUIRED FOR CONSTRUCTION. IF CONTRACTOR CANNOT OBTAIN A PERMIT, THEY MUST NOTIFY THE GENERAL CONTRACTOR IMMEDIATELY. • 37. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 38. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND/OR DRAWINGS PROVIDED BY THE SITE OWNER. CONTRACTORS SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 39. NO WHITE STROBE LIGHTS ARE PERMITTED. LIGHTING IF REOUIRED. WILL MEET FM STANDARDS AND REQUIREMENTS. 40. ALL COAXIAL CABLE INSTALLATIONS TO FOLLOW MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. ANTENNA MOUNTING 41. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO CURRENT ANSI/TIA-222 OR APPLICABLE LOCAL CODES. 42. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123 "ZINC (HOT -DIP GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS", UNLESS NOTED OTHERWISE. 43. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A153 "ZINC -COATING (HOT -DIP) ON IRON AND STEEL HARDWARE", UNLESS NOTED OTHERWISE. 44. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING IN ACCORDANCE WITH ASTM A780. 45. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH LOCK NUTS, DOUBLE NUTS AND SHALL BE TORQUED TO MANUFACTURER'S RECOMMENDATIONS. 46. CONTRACTOR SHALL INSTALL ANTENNA PER MANUFACTURER'S RECOMMENDATION FOR INSTALLATION AND GROUNDING. 47. ALL UNUSED PORTS ON ANY ANTENNAS SHALL BE TERMINATED WITH A 50-OHM LOAD TO ENSURE ANTENNAS PERFORM AS DESIGNED. 48. PRIOR TO SETTING ANTENNA AZIMUTHS AND DOWNTILTS, ANTENNA CONTRACTOR SHALL CHECK THE ANTENNA MOUNT FOR TIGHTNESS AND ENSURE THAT THEY ARE PLUMB. ANTENNA AZIMUTHS SHALL BE SET FROM TRUE NORTH AND BE ORIENTED WITHIN +/- 5% AS DEFINED BY THE RFDS. ANTENNA DOWNTILTS SHALL BE WITHIN +/- 0.5% AS DEFINED BY THE RFDS. REFER TO ND-00246. 49. JUMPERS FROM THE TMA'S MUST TERMINATE TO OPPOSITE POLARIZATION'S IN EACH SECTOR. 50. CONTRACTOR SHALL RECORD THE SERIAL #. SECTOR, AND POSITION OF EACH ACTUATOR INSTALLED AT THE ANTENNAS AND PROVIDE THE INFORMATION TO AT&T. 51. TMA'S SHALL BE MOUNTED ON PIPE DIRECTLY BEHIND ANTENNAS AS CLOSE TO ANTENNA AS FEASIBLE IN A VERTICAL POSITION. 52. ANTENNAS SHALL HAVE A 4'-0" MIN CENTER TO CENTER HORIZONTAL SEPARATION. TORQUE RFOUIRFMFNTS 53. ALL RF CONNECTIONS SHALL BE TIGHTENED BY A TORQUE WRENCH. 54. ALL RF CONNECTIONS. GROUNDING HARDWARE AND ANTENNA HARDWARE SHALL HAVE A TORQUE MARK INSTALLED IN A CONTINUOUS STRAIGHT LINE FROM BOTH SIDES OF THE CONNECTION. A. RF CONNECTION BOTH SIDES OF THE CONNECTOR. B. GROUNDING AND ANTENNA HARDWARE ON THE NUT SIDE STARTING FROM THE THREADS TO THE SOUD SURFACE. EXAMPLE OF SOLID SURFACE: GROUND BAR, ANTENNA BRACKET METAL 55. ALL 8M ANTENNA HARDWARE SHALL BE TIGHTENED TO 9 LB -FT (12 NM). 56. ALL 12M ANTENNA HARDWARE SHALL BE TIGHTENED TO 43 LB -FT (58 NM). 57. ALL GROUNDING HARDWARE SHALL BE TIGHTENED UNTIL THE LOCK WASHER COLLAPSES AND THE GROUNDING HARDWARE IS NO LONGER LOOSE. 58. ALL DIN TYPE CONNECTIONS SHALL BE TIGHTENED TO 18-22 LB -FT (24.4 - 29.8 NM). 59. ALL N TYPE CONNECTIONS SHALL BE TIGHTENED TO 15-20 LB -IN (1.7 - 2.3 NM). FILIER & POWFR CABLE MOUNTING 60. THE FIBER OPTIC TRUNK CABLES SHALL BE INSTALLED INTO CONDUITS. CHANNEL CABLE TRAYS. OR CABLE TRAY. WHEN INSTALLING FIBER OPTIC TRUNK CABLES INTO A CABLE TRAY bra OA, THEY SHALL BE INSTALLED INTO AN INTER DUCT AND A PARTITION BARRIER SHALL BE INSTALLED BETWEEN THE 600 VOLT CABLES AND THE INTER DUCT IN ORDER TO SEGREGATE CABLE TYPES. OPTIC FIBER TRUNK CABLES SHALL HAVE APPROVED CABLE RESTRAINTS EVERY (60) SIXTY FEET AND SECURELY FASTENED TO THE CABLE TRAY STaILM. NFPA 70 (NEC) ARTICLE 770 RULES SHALL APPLY. 61. THE TYPE TC-ER CABLES SHALL BE INSTALLED INTO CONDUITS. CHANNEL CABLE TRAYS, OR CABLE TRAY AND SHALL BE SECURED AT INTERVALS NOT EXCEEDING (6) SIX FEET. AN EXCEPTION; WHERE TYPE TC-ER CABLES ARE NOT SUBJECT TO PHYSICAL DAMAGE. CABLES SHALL BE PERMITTED TO MAKE A TRANSITION BETWEEN CONDUITS, CHANNEL CABLE TRAYS, OR CABLE TRAY WHICH ARE SERVING UTILIZATION EQUIPMENT OR DEVICES, A DISTANCE (6) SIX FEET SHALL NOT BE EXCEEDED WITHOUT CONTINUOUS SUPPORTING. NFPA 70 (NEC) ARTICLES 336 AND 392 RULES SHALL APPLY. 62. WHEN INSTALLING OPTIC FIBER TRUNK CABLES OR TYPE TC-ER CABLES INTO CONDUITS. NFPA 70 (NEC) ARTICLE 300 RULES SHALL APPLY. COAXIAL CABLE N0TE$ 63. TYPES AND SIZES OF THE ANTENNA CABLE ARE BASED ON ESTIMATED LENGTHS. PRIOR TO ORDERING CABLE, CONTRACTOR SHALL VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION LAYOUT AND NOTIFY THE PROJECT MANAGER IF ACTUAL LENGTHS EXCEED ESTIMATED LENGTHS. 62. CONTRACTOR SHALL VERIFY THE DOWN -TILT OF EACH ANTENNA WITH A DIGITAL LEVEL 63. CONTRACTOR SHALL CONFIRM COAX COLOR CODING PRIOR TO CONSTRUCTION. REFER TO "ANTENNA SYSTEM LABEUNG STANDARD" ND-00027 LATEST VERSION. 64. ALL JUMPERS TO THE ANTENNAS FROM THE MAIN TRANSMISSION LINE SHALL BE 1/2" DIA. LDF AND SHALL NOT EXCEED 6'-0". 65. ALL COAXIAL CABLE SHALL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE, IN AN APPROVED MANNER. AT DISTANCES NOT TO EXCEED 4'-0" OC. 66. CONTRACTOR SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS REGARDING BOTH THE INSTALLATION AND GROUNDING OF ALL COAXIAL CABLES, CONNECTORS, ANTENNAS, AND ALL OTHER EQUIPMENT. 67. CONTRACTOR SHALL WEATHERPROOF ALL ANTENNA CONNECTORS WITH SELF AMALGAMATING TAPE. WEATHERPROOFING SHALL BE COMPLETED IN STRICT ACCORDANCE WITH AT&T STANDARDS. GENERA' (Am F ANTI FOIIIPMFNT NOTES 68. CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ANTENNA, TMAS, DIPLEXERS, AND COAX CONFIGURATION, MAKE AND MODELS PRIOR TO INSTALLATION. 69. ALL CONNECTIONS FOR HANGERS, SUPPORTS. BRACING, ETC. SHALL BE INSTALLED PER TOWER MANUFACTURER'S RECOMMENDATIONS. 70. CONTRACTOR SHALL REFERENCE THE TOWER STRUCTURAL ANALYSIS/DESIGN DRAWINGS FOR DIRECTIONS ON CABLE DISTRIBUTION/ROUTING. 71. ALL OUTDOOR RF CONNECTORS/CONNECTIONS SHALL BE WEATHERPROOFED. EXCEPT THE RET CONNECTORS, USING BUTYL TAPE AFTER INSTALLATION AND FINAL CONNECTIONS ARE MADE. BUTYL TAPE SHALL HAVE A MINIMUM OF ONE-HALF TAPE WIDTH OVERLAP ON EACH TURN AND EACH LAYER SHALL BE WRAPPED THREE TIMES. WEATHERPROOFING SHALL BE SMOOTH WITHOUT BUCKUNG. BUTYL BLEEDING IS NOT ALLOWED. 72. IF REOUIRED TO PAINT ANTENNAS AND/OR COAX: A. TEMPERATURE SHALL BE ABOVE 50' F. B. PAINT COLOR MUST BE APPROVED BY BUILDING OWNER/LANDLORD. C. FOR REGULATED TOWERS. FAA/FCC APPROVED PAINT IS REOUIRED. 0. DO NOT PAINT OVER COLOR CODING OR ON EQUIPMENT MODEL NUMBERS. 73. ALL CABLES SHALL BE GROUNDED WITH COAXIAL CABLE GROUND KITS. FOLLOW THE MANUFACTURER'S RECOMMENDATIONS. A. GROUNDING AT THE ANTENNA LEVEL B. GROUNDING AT MID LEVEL, TOWERS WHICH ARE OVER 200.-0". ADDIDONAL CABLE GROUNDING REQUIRED. C. GROUNDING AT BASE OF TOWER PRIOR TO TURNING HORIZONTAL D. GROUNDING OUTSIDE THE EQUIPMENT SHELTER AT ENTRY PORT. E. GROUNDING INSIDE THE EQUIPMENT SHELTER AT THE ENTRY PORT. 74. ALL PROPOSED GROUND BAR DOWNLEADS ARE TO BE TERMINATED TO THE EXISTING ADJACENT GROUND BAR DOWNLEADS A MINIMUM DISTANCE OF 4'-0" BELOW GROUND BAR. TERMINATIONS MAY BE EXOTHERMIC OR COMPRESSION. 75. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ANTENNA AND THE COAX CONFIGURATION IS THE CORRECT MAKE AND MODELS, PRIOR TO INSTALLATION. 76. ALL CONNECTIONS FOR HANGERS, SUPPORTS. BRACING, ETC. SHALL BE INSTALLED PER TOWER MANUFACTURER'S SPECIFICATION & RECOMMENDATIONS. 77. ANTENNA CONTRACTOR SHALL FURNISH AND INSTALL A 12'-0" T-BOOM SECTOR ANTENNA MOUNT, IF APPLICABLE, INCLUDING ALL HARDWARE. SAFFTY ENFORCEMENT SAFETY IS OF PARAMOUNT CONCERN TO BOTH SITE WORKERS AND THE PUBLIC. 1. CONSTRUCTION WORK PRESENTS UNIQUE THREATS TO HEALTH AND SAFETY. THE CONTRACTOR IS RESPONSIBLE TO EDUCATE THEIR WORK FORCE OF THESE DANGERS AND LIMIT THEIR EXPOSURE TO HAZARDS. THIS EDUCATION SHALL INCLUDE BUT NOT BE LIMITED TO APPUCABLE TRAINING COURSES AND CERTIFICATIONS, PROPER PERSONAL PROTECTIVE EQUIPMENT USAGE. DAILY TAILGATE MEETINGS AND ANY OTHER PREVENTATIVE MEASURES WHICH MAY BE REASONABLY EXPECTED. THE CONTRACTOR AND ALL SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, ADJACENT AREAS AND ANY PROPERTY OCCUPANTS WHO MAY BE AFFECTED BY THE WORK UNDER CONTRACT. THE CONTRACTOR SHALL REVIEW ALL LANDOWNER, PRIME CONTRACTOR, CARRIER, OSHA, AND LOCAL SAFETY GUIDEUNES AND AT ALL TIMES SHALL CONFORM TO THE MOST RESTRICTIVE OF THESE STANDARDS TO ENSURE A SAFE WORKPLACE. 2. ALL SAFETY EQUIPMENT SHALL BE INSPECTED ACCORDING TO ALL OSHA AND INDUSTRY SCHEDULED INTERVALS AND ALL INSPECTIONS SHALL BE DOCUMENTED PER APPLICABLE CODES AND STANDARDS. 3. TOWER WORK PRESENTS ADDITIONAL THREATS TO HEALTH AND SAFETY. ALL TOWER WORKERS WORKING ON A TOWER MUST BE ADEOUATELY TRAINED AND MONITORED TO ENSURE THAT SAFE WORK PRACTICES ARE LEARNED AND FOLLOWED. AS REQUIRED BY OSHA, WHEN WORKING ON EXISTING COMMUNICATION TOWERS, EMPLOYEES MUST BE PROVIDED WITH APPROPRIATE FALL PROTECTION. TRAINED TO USE THIS FALL PROTECTION PROPERLY, AND THE USE OF FALL PROTECTION MUST BE CONSISTENTLY SUPERVISED AND ENFORCED BY THE CONTRACTOR. 4. ELECTRICAL WORK PRESENTS SPECIFIC THREATS TO THE HEALTH AND SAFETY OF WORKERS ON SITE. SPECIFICALLY ELECTROCUTIONS ARE THE FOURTH LEADING CAUSE OF DEATH ON CONSTRUCTION SITES. ALL ELECTRICAL WORKERS SHALL HAVE CURRENT CERTIFICATIONS WHICH SATISFY ALL TRAINING REOUIREMENTS FOR THE ELECTRICAL WORK THEY ARE PERFORMING PER OSHA STANDARDS. ALL ELECTRICAL WORKERS SHALL ADHERE TO ALL SAFETY RULES AND REGULATIONS FOR WORKER AND PUBUC SAFETY. ALL WORK SHALL BE PERFORMED BY QUALIFIED ELECTRICIANS TRAINED FOR THE TYPE OF WORK AND THE VOLTAGES PRESENT FOR EACH TASK. THE CONTRACTOR SHALL REVIEW ALL LANDOWNER, PRIME CONTRACTOR, CARRIER, OSHA, NFPA 70. AND LOCAL SAFETY GUIDELINES AND AT ALL TIMES SHALL CONFORM TO THE MOST RESTRICTIVE OF THESE STANDARDS TO ENSURE A SAFE WORKPLACE. OO 17 Y 111. asp at&t mobility J. .NasTec Network Solutions GPD GROUP Professional Corporation 520 South Main Street, Sulte 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 I PROJECT NO: 2018723.04.75142.01 DRAWN BY: CJM CHECKED BY: JG 0 05/21/113 ISSUED FOR CONSTRUCTION B FOR REVIEW Vy/) EW 1 EA:' RES 04/16/2020 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 1-5 & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE - ROOFTOP i SHEET TITLE GENERAL NOTES i SHEET NUMBER GN-2 GENERAL CONSTRUCTION NOTES I I AAA fArA4All 1 JIJ d (/N Wu+Iwo Community EXISTING AT&T ACCESS LADDER EXISTING AT&T EQUIPMENT ROOM AT GROUND LEVEL (SEE SHEET C-2) 5 EXISTING AT&T ANTENNAS IN FRP SHROUD (SEE SHEET RF— 1) ROOF AREA SCHEDULE REM AREA .X COVERED ROOFTOP 7597 SF — ANTENNA SHROUD 125 SF - 0.016X EXISTING ROOFTOP �� EXISTING ROOM'. RF SAFETY NOTE; AT&T HAS IMPLEMENTED RF SAFETY PROCEDURES AND ACTIONS ON THIS ROOFTOP SITE ALL GENERAL SAFETY RECOMMENDATIONS WILL BE FOLLOWED IN ORDER TO COMPLY WITH FCC & COUNTY GUIDELINES. LI '00? JUN 22 2010 Community Development at&t mobility EXP =.NasTec Network Solutions GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, 0H 44311 330.572.2100 Fax: 330.572.2102 PROJECT NO: 2018723.04.75142.01 DRAWN BY: CJM CHECKED BY: JG 0 05/21/16 ISSUED FOR GONSIRUCION 6 FOR REVIEW AQli/VY/.Ie _REAIEW R 22'x34' SCALE: 3/16' = 11'x17' SCALE: 3/32. = 1'-0. 4 2 0 4' =_s 04/16/2020 1 R IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER TNIS DOCUMENT. 1-5 & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE - ROOFTOP SHEET TITLE OVERALL SITE PLAN SHEET NUMBER C-1 OVERALL SITE PLAN J 1 { •7 :4 •1 :{ :1 :1 :'1 .'1 t• ::r .1 EXISTING BATTERY RACK W/ (20) MARATHON BATTERIES EXISTING AT&T ACCESS LADDER (12) EXISTING OIPLEXERS MOUNTED TO WALL (6) TO BE REMOVED EXISTING COAX ENTRY PORT EXISTING BATTERY RACK W/ (4) MARATHON BATTERIES CO 00 CO 00 0 CO; CO 00! cx_. _x_, ; y_.'_ o x_. _ x --)1Y) _" EXIS11NG GSM CABINET Q 0 U 0 EXISTING CABLE RUNS FROM AT&T EOUIPMENT ROOM ROUTED THROUGH ATTIC CABLE TRAY TO FRP CUPOLA (1) PROPOSED FIBER TRUNK & (2) PROPOSED DC TRUNKS TO FOLLOW EXISTING CABLE ROUTING a U 5 T 3 II I EXISTING POWER CABINET W/ (12) MARATHON BATTERIES EXISTING UMTS CABINET EXISTING TELCO BOARD EXISTING ELECTRICAL PANEL INSTALL (1) PROPOSED RAYCAP & (1) PROPOSED DC TO DC CONVERTOR W/ (4) CONVERTORS IN EXISTING FIF RACK EXISTING FIBER NEMA BOX— Lfw-elog7 ✓acr too :fa:, iF" RV. 4 iNe at&t mobility •=.NasTec Network Solutions GPD��GROUP/� Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 49311 330.572.2100 Fax: 330.572.2102 PROJECT NO: 2018723.04.75142.01 DRAWN BY: CJM CHECKED BY: JG A 0 05/21/16 ISSUED FOR CONSTRUCTION B 03/22/18 ISSUED FOR REVIEW A REVIEW P PIRES 04/16/2020 22%34 SCALE: 1' = 1'—O' 11-x17 SCALE: 1/2' = 1'-0" IT IS A VIOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. 1-5 & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE - ROOFTOP SHEET TITLE EQUIPMENT LAYOUT I SHEET NUMBER C-2 6 O 1' AA1Aa n,C'1. /NI11A,5 EQUIPMENT LAYOUT 1 i LUIUY Community. NOTE: THE PASSING STRUCTURAL ANALYSIS FOR THE EXISTING FAUX CUPOLA AT THIS SITE WAS COMPLETED BY GPD GROUP ON APRIL 16, 2018. CONFORMING TO TIA-222—G. ACCORDING TO THE GPD GROUP STRUCTURAL ANALYSIS, THE CUPOLA HAS SUFFICIENT CAPACITY. EXISTING AT&T ACCESS LADDER ' (1) PROPOSED FIBER TRUNK & (2) PROPOSED DC TRUNKS TO FOLLOW EXISTING CABLE ROUTING PROPOSED EXHAUST FAN (SEE SHEET RF 3) 1 II II II II r--•�Jo EXISTING & PROPOSED AT&T ANTENNAS, SEE SHEET RF-1 FOR DETAILED PLAN . nn W n. I 1• •I ICI !�I I:I ,)♦L' a ■ ui1 11 11 11 II • I •I Al I • 1-1t1--'A1-14I ;IMMUNE, EXISTING & PROPOSED AT&T EQUIPMENT ON CUPOLA WALL, SEE SHEET RF-1 FOR DETAILED PLAN PROPOSED AIR INTAKE LOUVER. 24x24 (SEE SHEET RF-3) Lill_ LI I u l 1 U LIII U II u u e� � ■�■�■��� i�1� i����� ■�■� inirMiMMEMENOIMM■ . 1,. 1.111.1111111111.11....1 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111.1111111111.111111 I II III 11 11 II III II 11 1 1 TT 11 1 1 T 1 1 1 TT 1 1 1 1 TT 1 1 1 1 TT 11 1 1 T 1 11 T 1 11 T 1 11 T7 1 11 Tl 1 11 T 1 11 T7 1 1 1 1 T 1 1 1 T 1 1 1 TT11 '1 1 11 ITT\ 1. TYPES AND SIZES OF THE ANTENNA CABLE ARE BASED ON ESTIMATED LENGTHS. PRIOR TO ORDERING CABLE, CONTRACTOR SHALL VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION LAYOUT AND NOTIFY THE PROJECT MANAGER IF ACTUAL LENGTHS EXCEED ESTIMATED LENGTHS. 2. CONTRACTOR SHALL VERIFY THE DOWN —TILT OF EACH ANTENNA WITH A DIGITAL LEVEL. 3. CONTRACTOR TO CONFIRM COAX COLOR CODING PRIOR TO CONSTRUCTION. REFER TO "ANTENNA SYSTEM LABEUNG STANDARD" ND-00027. REFER TO THE LATEST VERSION. 4. ALL JUMPERS TO THE ANTENNAS FROM THE MAIN TRANSMISSION LINE WILL BE 1/2" DIA. LDF AND SHALL NOT EXCEED 6'-0". 5. ALL COAXIAL CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE. IN AN APPROVED MANNER. AT DISTANCES NOT TO EXCEED 4'-0" OC. 6. CONTRACTOR MUST FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS REGARDING BOTH THE INSTALLATION AND GROUNDING OF ALL COAXIAL CABLES, CONNECTORS. ANTENNAS. AND ALL OTHER EQUIPMENT. 7. WEATHERPROOF ALL ANTENNA CONNECTORS WITH SELF AMALGAMATING TAPE. WEATHERPROOFING SHALL BE COMPLETED IN STRICT ACCORDANCE WITH AT&T STANDARDS. 8. CONTRACTOR SHALL GROUND ALL EOUIPMENT. INCLUDING ANTENNAS, RET MOTORS, TMA'S, COAX CABLES, AND RET CONTROL CABLES AS A COMPLETE SYSTEM. GROUNDING SHALL BE EXECUTED BY OUAUFIED WIREMEN IN COMPLIANCE WITH MANUFACTURER'S SPECIFICATION AND RECOMMENDATION. 9. CONTRACTOR SHALL PROVIDE. STRAIN—REUEF AND CABLE SUPPORTS FOR ALL CABLE ASSEMBLIES, COAX CABLES, AND RET CONTROL CABLES. CABLE STRAIN—REUEFS AND CABLE SUPPORTS SHALL BE APPROVED FOR THE PURPOSE. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 10. CONTRACTOR TO VERIFY THAT EXISTING COAX HANGERS ARE STACKABLE SNAP IN HANGERS. IF EXISTING HANGERS ARE NOT STACKABLE SNAP IN HANGERS THE CONTRACTOR SHALL REPLACE EXISTING HANGERS WITH NEW SNAP IN HANGERS IF APPLICABLE. COAXIAL ANTENNA CABLE NOTES 2 22 x34" SCALE: 1/16" — .......� 11"x17" SCALE: 1/32" = 1'-0" 16 128 4 0 16' RECER'ED JUN 22 2018 Community f)avalnpm2 t at&t mobility I .NasTec Network Solutions GPD GROUP Professional Corporation 520 Smith Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 PROJECT NO: 2018723.04.75142.01 DRAWN BY: CJM CHECKED BY: JG 0 05/21/18 ISSUED FOR CONSTRUCTION B 03 18 ISSUED FOR REVIEW 01I/4B REVIEW 5/22/18 ES 04/16/2020 CE R IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 1-5 & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE - ROOFTOP SHEET TITLE TOWER ELEVATION SHEET NUMBER C-3 II III ►I ►I II II II II II II II II 11 III 11 III 11 II 11 II 11 II PROPOSED ELEVATION NOT USED 3 (N) - NEW (X) - EXISTING (XR) - EXISTING/RELOCATED (XG) - EXISTING/GROUND (E) - ELECTRICAL (M) - MECHANICAL EXISTING ANTENNA CONFIGURATION AND CABLE SCHEDULE POS STATUS ANTENNA ANTSECTOR HEIGHT AZIMUTH TMA/RRU DC SURGE AND DISTRIBUTION CABLE TYPE A 1 EXISTING COMMSCOPE (X) SBJAH4-1D65B—DL 49'-0' AGL 135' (1) RRH2x40W-07L (X) (1) RRH2x60-850 (X) (1) B25 RRH4x30-4R (X) (1) RRH4x24—WCS-4R (X) (1) RAYCAP (X) DC6-48-60-18-8F (2) DC (X) (1) FIBER (X) 2 EXISTING dbSPECTRA (X) SPD2P6516XLH 135' (2) TMA (%) (4) DIPLEXER (X) (2) COAX (X) B 1 EXISTING COMMSCOPE (X) SBJAH4-1D658—OL 49'-0' AGL 270. (1) RRH2x40W-07L (X) (1) RRH2x60-850 (X) (1) 825 RRH4x30-4R (X) (1) RRH4x24—WCS-4R (X) (1) RAYCAP (X) DC6-48-60-18-8F (2) DC (X) (1) FIBER (X) 2 EXISTING dbSPECTRA (X) SPD2P6516XLH 270' (2) TMA (%) (4) DIPLEXER (X) (2) COAX (X) C 1 EXISTING COMMSCOPE (X) SBJAH4-1065E—DL 49'-0' AGL 45. (1) RRH2x40W-071 (X) (1) RRH2x60-850 (X) (1) 825 RRH4x30-4R (X) (1) RRH4x24—WCS-4R (X) SHARED W/ Al 2 EXISTING dbSPECTRA (X) SPD2P6516XLH 45' (2) TMA (X) (4) DIPLEXER (X) (2) COAX (X) NOTE: REMOVE (3) TMAs FROM POSITION 2 (FIELD VERIFY EXACT LOCATION) EXISTING AT&T PANEL ANTENNA, 1 PER SECTOR IN POSITION 1 TO REMAIN (COMMSCOPE SBJAH4-10658—DL) (2) EXISTING AT&T DC6s TO REMAIN EXISTING ANTENNA LAYOUT 5 5 EXISTING FIBER SLACK BOX EXISTING WOOD LADDER TO ANTENNAS EXISTING AT&T CABLE ROUTE EXISTING AT&T GPS ANTENNA EXISTING AT&T PANEL ANTENNA, 1 PER SECTOR IN POSITION 2 TO BE REMOVED (dbSPRECTRA SPD2P65XLH) EXISTING AT&T GPS ANTENNA (12) EXISTING AT&T RRHs FOR POSITION 1 TO REMAIN (4) PER SECTOR MOUNTED TO CUPOLA WALL 3/4" = 1'- 1 (N) - NEW (X) - EXISTING (XR) - EXISTING/RELOCATED (XG) EXISTING/GROUND (E) - ELECTRICAL (I) MECHANICAL PROPOSED ANTENNA CONFIGURATION AND CABLE SCHEDULE SECTOR POS STATUS ANTENNA TECH. ANTENNA q HEIGHT AZIMUTH TMA/RRU DC SURGE AND DISTRIBUTION CABLE TYPE A 1 EXISTING COMMSCOPE (X) SBJAH4-1D658—DL LTE 1900/850/ 700/WCS 49-0'' AGL 135, (1) RRH2x40W-07L (X) (1) RRH2x60-850 (X) (1) B25 RRH4x30-4R (X) (1) RRH4x24—WCS-4R (X) (1) RAYCAP (X) DC6-48-60-18-8F (2) DC (X) (1) FIBER (X) 2 PROPOSED KMW (N) EPB0-654L8H6—L2 UMTS 1900/850 LTE 700/AWS 135' (1) FLEXI RRH 4T4R (1) 1(N) 666A RRH4x45 (N) (1) TMA (X) (2) DIPLEXER (X) (2) COAX (X) B 1 EXISTING COMMSCOPE (X) SBJAH4-1D658—DL LTE 1900/850/ 700/WCS 49'-0' AGL 270, (1) RRH2x40W-07L (X) (1) RRH2x60-850 (X) (1) 825 RRH4x30-4R (X) (1) RRH4x24—WCS-4R (X) (1) RAYCAP (X) DC6-48-60-18-8F (2) DC (X) (1) FIBER (X) 2 PROPOSED MW (N) EP80K654U3H6—L2 UMT1900/850 LTE 700/AWS 270' (1) FLEXI RRH 4T4R B14 (N) (1) B(6A RR1) IAA (X) (N) (2) DIPLEXER (X) (2) COAX (X) C 1 EXISTING COMMSCOPE (X) SBJAH4-1D658—DL LTE 1900/850/ 700/WCS _ 491900/850'-0 AGL 45, (1) RRH2x40W-07L (X) (1) RRH2x60-850 (X) (1) B25 RRH4x30-4R (X) (1) RRH4x24—WCS-4R (X) (1) RAYCAP (N) DC6-48-60-18-8C (2) DC (N) (1) FIBER (N) 2 PROPOSED EP80K654L8M6—L2 UMTSLTE 700/AWS 45' (1) FLEXI RRH 4T4R B14 (N) (1) B(1)GA �RRNM�z)5 (N) (2) DIPLEXER (X) (2) COAX (X) 1. INTAKE AIR LOUVER: GREENHECK MODEL ESD-635 OR APPROVED EQUAL. 24%24X6, 1950 CFM AIRFLOW, 879 FPM VELOCITY, 12.SP, 1.65 SF FREE AREA. PROVIDE LOUVER WITH BIRD SCREEN, ALUMINUM FILTER RACK AND EXTENDED SILL. 2. INTAKE AIR CONTROL DAMPER: GREENHECK MODEL VCD.40 OR APPROVED EQUAL, 24x24x4, EXTRUDED ALUMINUM, PARALLEL AIRFOIL BLADES, TPE BLADE SEAL MATERIAL. PROVIDE WITH BEUMO MODEL TF8120 ACTUATOR. 3. UNE VOLTAGE THERMOSTAT: GREENHECK MODEL #: 380044 OR APPROVED EOUAL, 30-110F RANGE, 120V-1PH. 16A CAPACITY. 4. WALL TYPE, PROPELLER EXHAUST FAN: GREENHECK MODEL #: SET —16-438—B4 OR APPROVED EQUAL, 1450 CFM AT 32' SP, 1160 FAN RPM, .24 BHP, 1/4 HP, 120V-1PH POWER. FURNISH WITH NEMA 3 DISCONNECT AND BD-320—PB-18x18 BACKDRAFT DAMPER. EXISTING ACCESS DOOR (1) PROPOSED AT&T DC/FIBER DC6 ON NEW UNISTRUT ABOVE DOORWAY (3) PROPOSED AT&T RRHs MOUNTED TO NEW UNISTRUT ABOVE EXISTING DOORWAY ........ EXISTING AT&T PANEL ANTENNA. 1 PER SECTOR IN POSRION 1 TO REMAIN (COMMSCOPE SBJAH4— 1 D65B—DL) (2) EXISTING AT&T DC6s TO REMAIN PROPOSED ANTENNA LAYOUT 5 EXISTING FIBER SLACK BOX EXISTING WOOD LADDER TO ANTENNAS (3) PROPOSED AT&T RRHs MOUNTED TO NEW UNISTRUT ABOVE EXISTING DOORWAY EXISTING AT&T CABLE ROUTE EXISTING AT&T GPS ANTENNA PROPOSED AT&T PANEL ANTENNA, 1 PER SECTOR IN POSITION 2 (KMW EPB0-654L8H6—L2) EXISTING AT&T GPS ANTENNA (12) EXISTING AT&T RRHs FOR POSITION 1 TO REMAIN (4) PER SECTOR MOUNTED TO CUPOLA WALL E ; EL JUN 22 2018 3/4" = 1'- Ata...01\ I at&t mobility :.MasTec Network Solutions GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OM 44311 330.572.2100 Fax: 330.572.2102 PROJECT NO: 2018723.04.75142.01 DRAWN BY: CJM CHECKED BY: JG 0 05/21/18 ISSUED FOR CONSTRUC110N 8 03/22/18 ISSUED FOR REVIEW A 03/01448^IaUFRO FOR RENEW ' Ft�N3FS N4/ 14/2 2O - ra A VIOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER T11E DIRECTION OF A UCENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. 1-5 & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE - ROOFTOP SHEET TITLE ANTENNA CONFIGURATIONS SHEET NUMBER RF-1 Community 1 C VF-,:'t."?"iv It w PROPOSEDNTENNAPIPE2 3MO ANTENNA MOUNT ANDREW P/N p. MT 220-108" MINIMUM LENGTH TYPICAL PER LTE APPLICATION �j <P1000 i.. ' 4!. ill N MOUNTING OPTIONS ARE INCLUDED PRODUCTS WITH ANTENNA PURCHASE PROPOSED ANTENNA MOUNTING BRACKET ANDREW P/N 8. DB5083 PROPOSED ANTENNA PROPOSED ANTENNA MOUNTING BRACKET ANDREW P/N #. DB380 II KMW EPBQ-654L8H8-L2 mobility DIMENSIONS, HxWxD: 73"x21"x6.3" NET WEIGHT: 72.8 lbs a 0 UNISTRUT CHANNEL (2ROPOS�,� END CAPS R (VIP) 2 zap _ p IL ° lc_ r IasTec Network Solutions 1 J iz �' Ir us LIUUU /.� GPD GROUP Professional corporation 520 South Hain Street, Sulte 2531 anon, OH 44311 330.572.2100 Fax: 330.572.2102 21" ANCHOR/FASTENER (MIN.) (SEE NOTE 2) CLEARANCE ELEVATION PROPOSED ANTENNA SPECIFICATIONS NO SCALE 2 ANTENNA MOUNTING DETAIL NO SCALE 3 NOTES' 1IS r 11* .,• KMW RRH 4T4R B14 1. A SUPPORT FOR A SINGLE RRH SHALL HAVE A MINIMUM OF TWO ANCHORS/FASTENERS FOR EACH UNISTRUT CHANNEL. 2. INSTALL ANCHORS/FASTENERS A MAXIMUM OF 2'-0" ON CENTERS. • WOOD STUDS — 1 4"0 LAG BOLT W/ 1" EMBEDMENT IN WOOD • CONCRETE — 1/4 0 HILTI KWIK BOLT III W/ 1-1/2" EMBEDMENT OR EQUIVALENT • THROUGH BOLT — 1/4"0 A36/A307 THREADED ROD W/ NUTS AND WASHERS MASONRY — 1/2"0 HILTI HY20 W/6" EMBEDMENTft,j7 ANCHORS AND UNISTRUT CHANNEL SHALL HAVE HOT —DIPPED GALVANIZED FINISH. 4. MOUNT RRH TO UNISTRUT WITH 3/8"0 UNISTRUT BOLTING HARDWARE AND SPRING NUTS. TYPICAL FOUR PER BRACKET. SUBCONTRACTOR SHALL SUPPLY. 5. NO PAINTING OF THE RRH OR SOLAR SHIELD IS ALLOWED. ��* + - l'; 1 I I, I I Oil I l `>tl tF ��" ;, ��� Jail. I Sit _ DIMENSIONS, WxDxH: WEIGHT. WITHOUT MOUNTING `, ( �' ` --} a�' •1 if � 11.8"x15.7"x4.7 KIT: 32.6 Ibs � N PROJECT NO: 2018723.04.75142.01 , r ALCATEL-LUCFNT RUA RRH4X45 0 0 DRAWN BY: CJM , DIMENSIONS, HzWeD: 25.8"z11.8"x7.2" I Illilllli II CHECKED 8Y: JG WEIGHT, WITHOUT illI sy MOUNTING KIT: 25.8 kg (56.8 Ibs)• i H4II4M 0 )0 o 05/21/18 ISSUED FOR CONSTRUCTON e 03/22/18 IssutD FOR REVEw , Ll ) f 0 ,`G i (�- �Q p "^'� -avj !I r��j '� r %I qti':1' ,gip 55771 F �Cii�Slt �_; y sr I°, + ''. 5/22/18 MI � as all� FRONT RRH MOUNTING DETAIL NO SCALE 1 PROPOSED RRH DETAIL NO SCALE 4 PROPOSED RRH DETAIL NO SCALE 5 RAYCAP DC6-48-60-18-8C 11. DIMENSIONS. WxDxH: 280x610mm (11"x24") I I vPIRES 04/16/2020 jr ] NOMINAL OPERATING VOLTAGE: 48 VDC J_" f " 4 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESSON OF A UCEIISED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. NOMINAL DISCHARGE CURRENT: 20 kA 8 20Ps �1'(4 / •'?y =:k' MAXIMUM DISCHARGE CURRENT: 60 kA 8/2OPs f. 4`. • MAXIMUM CONTINUOUS OPERATING VOLTAGE: 75 VDC rtr VOLTAGE PROTECTION RATING: 400 V r`r?` WIND LOADING: 150 MPH (SUSTAINED *4'.4 ` 195 MPH (GUST) i nt C .4. = TOTAL WEIGHT: 32.8 lbs {,, a .i . ' - `''i #Y*lt ` i 7 r'; jI + 43 T x 11 a• C• 4, :"-;;1 �- r',1 t- ,. 4 1-5 & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE - ROOFTOP `$� 1 _- , L... `I I �+, SHEET TITLE ANTENNA & RRH UNIT DETAILS - I 618.5' SHEET NUMBE•R RF-2 '>t.d' Ao 1%' / (� NOT USED NO SCALE 6 NOT USED NO SCALE 7 DC6 DETAIL I NO SCALE I 8 L+ 8 Community !i•........ "c "t w- DRAWING VIEWED FROM INTERIOR -" --..- 11.75 10.25 1.0 ik ��` If at�t ��� mobility 1 -0-Np 22 00 / I....- 11 f •■ •M a sTe Network Solutions c 22.00 WALL OPENING 18.5 SQ. MOTOR IS ACCESSIBLE FROM INTERIOR OF BUILDING THIS IS AN EXHAUST FAN DUE TO MOTOR ORIENTATION THIS FAN HAS 4 BLADES DAMPER MOUNTED BY OTHERS • ��I II 16 38 U EXHAUST AIRFLOW + INTERIOR EXTERIOR GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 94311 330.572.2100 Fax: 330.572.2102 EXHAUST FAN NO SCALE 2 EXHAUST FAN SECTION NO SCALE 3 18 DAMPER 18 3.875 1.5 i II� PROJECT NO: 2018723.04.75142.01 DRAWN BY: CJM CHECKED BY: JG 0 05/21/1B ISSUED FOR CONSTRUCTION B 03 18 LSSuED FOR REVIEW A.� p ,1.� u, FOR REVIEW .'I Ste: ,-or; fig.... 1.75 SECTION VIEW w0 ,�° -' �``% LI �h;%,��i ¢" ,•TYP. 4 :t:..•..//0/ 55771 t RCCI51T�ifru i �SlONA1:F`JG 5/22/18 � ,. NOT USED NO SCALE 1 DAMPER NO SCALE 4 DAMPER SECTION NO SCALE G" _ 04/16/2020 ! GE O0 Li, L $ A a ri$,r v r....., JUN 22 2018 Community Development 1 ExPIFE. IF IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. 1-5 & 1-405 10032276 5711 S 152ND ST 88 TUKWILA,LTE- ROOFTOP SHEET TITLE EQUIPMENT DETAILS SHEET NUMBER RF-3 NOT USED NO SCALE 6 NOT USED NO SCALE 7 DC6 DETAIL NO SCALE 8 -� �` 11181101.111611) ���� mobility NOTE: GROUND LEAD INSIDE RUBBER GROMMET TO BE ATTACHED WITH X-CROSS ZIP TIES TO BRACKET. DO NOT USE SNAP -IN HANGERS AROUND GROUNDS. SECTOR ANTENNA elNasTec Network Solutions ANTENNA PIPE MOUNT TOP JUMPER CABLE � NEW #2 AWG GPD GROUP Professional Corporation Suite 2531 5205ouM Man Street, H94311 330.572.2100 Fax: 330.572.2102 • NOT USED NO SCALE 2 NOT USED NO SCALE 3 EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND NEWTON INSTRUMENT COMPANY, INC. BAR SHALL HAVE AN IDENTIFICATION TAG ATTACHED AT EACH END THAT WILL IDENTIFY ITS ORIGIN AND DESTINATION BUTNER, N.C. PROJECT NO: 2018723.04.75142.01 GROUND TO EXISTING SECTOR GROUND BAR \ \ RRUS NO REOUIRED PART NUMBER DESCRIPTION SECTION "P" - SURGE PROTECTORS 1 1 1/4"x4"x30" SOLID GROUND BAR (SEE NOTE 2) (EC) GENERATOR FRAMEWORK (IF AVAILABLE) (EC) TELCO GROUND BAR (#2 AWG) (d2 AWG) CHECKED BY: JG O 2 A-6056 WALL MOUNTING DOUBLE CRIMP (EC) COMMERCIAL POWER COMMON NEUTRAL/GROUND BOND (3/0) UNIT BRACKET CONNECTION (EC) FIBER GROUND BAR (#2 AWG) 0 2 3061-4 INSULATORS RING INTERIOR GROUND 0 © (AT&T)EC) WER ECT,FlER FRAMESROOM ENCE GROUND BAR AT& R (#2 AWG) — 0 SECTION "A" - SURGE ABSORBERS �,G+." JUMPER CABLES O4 4 3012-1 5/8"-11x1" H.H.C.S. 0 11 �F /ice 0 05/21/18 ISSUED FOR CONSTRUCTION OS 4 3015-8 5/8" LOCKWASHER �� ': ( 0 (EC) INTERIOR GROUND RING (12 AWG) Q (EC) EXTERNAL EARTH GROUND FIELD (BURIED (EC) METALLIC COLD WATER PIPE (IF AVAILABLE) GROUND RING) (//2 AWG) (1/0 AWG) EX. SECTOR GROUND BAR (1) PER SECTOR (TYP.) • RAYCAP UNIT 0 03/22/18 ,..1.1.. FOR RENEW A _Alai yTi�ilirliL"yam �- DETAIL NOTES: 1i rg P 4 (EC) BUILDING STEEL (IF AVAILABLE) (1/0 AWG) <' ii' 1. EXOTHERMICALLY WELD g2 AWG BARE TINNED SCUD " F (SEE NOTE 1) SECTION "I" - ISOLATED GROUND ZONE • • r VAS ' ,r\� o /4, • G .�' G�, �a I I✓ _ _ .. '( ^^ s 1 _ !+r=I„� F: .� I t yt. e' COPPER CONDUCTOR TO GROUND BAR. ROUTE CONDUCTOR TO BURIED GROUND RING AND PROVIDE PARALLEL EXOTHERMIC WELD. 2. THE INSTALLER SHALL USE PERMANENT MARKER TO DRAW THE LIKE BETWEEN SECTION AND LABEL EACH SECTION ("P", "A", "I" WITH 1" HIGH LETTERS � / y 1/4" 13" 4„ 6 13. (AT&T) ALL ISOLATED GROUND REFERENCE (AT&T) GROUND WINDOW BAR EX. COLLECTION GROUND BAR - NEW #2 AWG GROUD TO EXISTING COLLECTION GROUND GROUND TO EXISTING TOWER GROUND BAR BAR FIBER (MGB) REFERENCE GROUNDING BAR DETAIL NO SCALE 4 .�t�,� +p0 RF 50744 40 .c� GIS1T� SS��'V/�L FN� p I''2/T0 6 AWG STRANDED CU CON4 OR DUCTOR WITH GREEN, BODY, THWN-2 INSULATION TO LOW NOISE AMPUFIER TO TRANSMIT Z GROUND BAR ON WALL OR FLOOR I I ' I ' ' , ' UNITS (LNA) AND RECEIVE RX1/RX2 COAX JUMPER REOUIRED PER MANUFACTURER RECOMMENDATION OR FOR EASE OF CONNECTION (TYP) (WHEN 1 ■ • ANTENNA REQUIRED) RX1/RX2 ANTENNA 2 1 ■ `D T I �I � ( ✓ + {//'15 I' TIES: 02/03/2020 IF 5 A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 0 Q Q Q Q 0 1/16" Q rL�J, CONNECTOR I KIT (TYP)—^ iiI A rL I I I I . J rL•J, I I= i STANKIT DARDGROUNDING I I �� I—S & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE — ROOFTOP NEW #2 AWG GROUND TO GROUND BAR EQUIPMENT CABINET (GROUND ALL NEW CABINETS)WEATHERPROOFING \ / ANTENNA CABLE TO '\,_ �. BTS (TYP) FROM LNA ••� . i • REOUIRED)--., EQUIPMENT • (2) TWO EXOTHERMIC TO BE USED (WHEN ., AWG STRANDED COPPER CO CONDUCTOR WITH GREEN, 600V, THWN-2 INSULATION GROUND BAR SHEET TITLE GROUNDING DETAILS •--� NOTE: WITH #2 AWG SOLID BARE TINNED COPPER GROUND CONDUCTOR, � GROUNDING BAR• ANDREW PART # UGBKIT-0424-T (TINNED). A LOCKBOX IS EXOTHERMIC WELD TO BURIED GROUND RING AND GROUND BAR PVC 0N(C CONDOR 4 SCH 0 TYPE NMC) CONDUIT WITH STRAP WITHIN TWO INCHES OF CONDUIT END MECHANICALLY REOUIRED AT GRADE TASSCO PART # SECURE GROUNDING 351546. ANTENNA HEIGHT WILL DETERMINE BAR TO STRUCTURE NUMBER OF GROUNDING BARS AND THEIR LOCATION SHEET NUMBER EXISTING EQUIPMENT BOND ALL METALLIC OBJECTS GROUND RING TO GROUND BAR AT EQUIPMENT LOCATIONS. GROUNDING SCHEMATIC NO SCALE 1 GROUNDING BAR DETAIL NO SCALE 5 COAX GROUNDING DETAIL NO SCALE 6 JU 1 44 Lind C (1FY1 .Y.I I r1:hJ PART 1 - GENFRAI B. CONDUCTORS AND CABLE: 1.1 GENERAL CONDITIONS: A. CONTRACTOR SHALL INSPECT THE EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BID. ANY QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTORS FUNCTIONS. THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. B. THE CONTRACTOR SHALL OBTAIN PERMITS, LICENSES, MAKE ALL DEPOSITS. AND PAY ALL FEES REQUIRED FOR THE CONSTRUCTION PERFORMANCE FOR THE WORK UNDER THIS SECTION. C. DRAWINGS SHOW THE GENERAL ARRANGEMENT OF ALL SYSTEMS AND COMPONENTS COVERED UNDER THIS SECTION. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS. DRAWING SHALL NOT BE SCALED TO DETERMINE DIMENSIONS. 1.2 LAWS. REGULATIONS, ORDINANCES, STATUTES AND CODES. A. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, AND ALL APPUCABLE LOCAL LAWS. REGULATIONS, ORDINANCES. STATUTES AND CODES. CONDUIT BENDS SHALL BE THE RADIUS BEND FOR THE TRADE SIZE OF CONDUIT IN COMPUANCE WITH THE LATEST EDITIONS OF NEC. 1.3 REFERENCES: A. THE PUBUCATIONS USTED BELOW ARE PART OF THIS SPECIFICATION. EACH PUBUCATION SHALL BE THE LATEST REVISION AND ADDENDUM IN EFFECT ON THE DATE. THIS SPECIFICATION IS ISSUED' FOR CONSTRUCTION UNLESS OTHERWISE NOTED. EXCEPT AS MODIFIED BY THE REQUIREMENT SPECIFIED HEREIN OR THE DETAILS OF THE DRAWINGS, WORK INCLUDED IN THIS SPECIFICATION SHALL CONFORM TO THE APPLICABLE PROVISION OF THESE PUBUCATIONS. 1. ANSI/IEEE (AMERICAN NATIONAL STANDARDS INSTITUTE) 2. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS) 3. ICEA (INSULATED CABLE ENGINEERS ASSOCIATION) 4. NEMA (NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION) 5. NFPA (NATIONAL FIRE PROTECTION ASSOCIATION) 6. OSHA (OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION) 7. UL (UNDERWRITERS LABORATORIES INC.) 8. AT&T GROUNDING AND BONDING STANDARDS TP-76416 1.4 SCOPE OF WORK A. WORK UNDER THIS SECTION SHALL CONSIST OF FURNISHING ALL LABOR, MATERIAL, AND ASSOCIATED SERVICES REQUIRED TO COMPLETE REOUIRED CONSTRUCTION AND BE OPERATIONAL. B. ALL ELECTRICAL EOUIPMENT UNDER THIS CONTRACT SHALL BE PROPERLY TESTED, ADJUSTED, AND ALIGNED BY THE CONTRACTOR. C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXCAVATING. DRAINING, TRENCHES, BACKFIWNG, AND REMOVAL OF EXCESS DIRT. D. THE CONTRACTOR SHALL FURNISH TO THE OWNER WITH CERTIFICATES OF A FINAL INSPECTION AND APPROVAL FROM THE INSPECTION AUTHORITIES HAVING JURISDICTION. E. THE CONTRACTOR SHALL PREPARE A COMPLETE SET OF AS -BUILT DRAWINGS. DOCUMENT ALL WIRING EQUIPMENT CONDITIONS, AND CHANGES WHILE COMPLETING THIS CONTRACT. THE AS -BUILT DRAWINGS SHALL BE SUBMITTED AT COMPLETION OF THE PROJECT. PART 2 - PRODUCTS 2.1 GENERAL A. ALL MATERIALS AND EQUIPMENT SHALL BE UL LISTED, NEW. AND FREE FROM DEFECTS. B. ALL ITEMS OF MATERIALS AND EQUIPMENT SHALL BE ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION AS SUITABLE FOR THE USE INTENDED. C. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. D. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED. 10,000 AIC MINIMUM. VERIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EOUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PER THE GOVERNING JURISDICTION. 2.2 MATERIALS AND EQUIPMENT: A. CONDUIT: 1. RIGID METAL CONDUIT (RMC) SHALL BE HOT -DIPPED GALVANIZED INSIDE AND OUTSIDE INCLUDING ENDS AND THREADS AND ENAMELED OR LACQUERED INSIDE IN ADDITION TO GALVANIZING. 2. LIQUIDTIGHT FLEXIBLE METAL CONDUIT SHALL BE UL LISTED. 3. CONDUIT CLAMPS, STRAPS AND SUPPORTS SHALL BE STEEL OR MALLEABLE IRON. ALL FITTINGS SHALL BE COMPRESSION AND CONCRETE TIGHT TYPE. GROUNDING BUSHINGS WITH INSULATED THROATS SHALL BE INSTALLED ON ALL CONDUIT TERMINATIONS. 4. NONMETALLIC CONDUIT AND FITTINGS SHALL BE SCHEDULE 40 PVC. INSTALL USING SOLVENT -CEMENT -TYPE JOINTS AS RECOMMENDED BY THE MANUFACTURER. B. CONDUCTORS AND CABLE: 1. CONDUCTORS AND CABLE SHALL BE FLAME-RETARDANT, MOISTURE AND HEAT RESISTANT THERMOPLASTIC, SINGLE CONDUCTOR, COPPER. TYPE THHN/THWN-2. 600 VOLT. SIZE AS INDICATED. #12 AWG SHALL BE THE MINIMUM SIZE CONDUCTOR USED. 2. #10 AWG AND SMALLER CONDUCTOR SHALL BE SOLID OR STRANDED AND #8 AWG AND LARGER CONDUCTORS SHALL BE STRANDED. 3. SOLDERLESS, COMPRESSION -TYPE CONNECTORS SHALL BE USED FOR TERMINATION OF ALL STRANDED CONDUCTORS. 4. STRAIN-REUEF SUPPORTS GRIPS SHALL BE HUBBELL KELLEMS OR APPROVED EQUAL CABLES SHALL BE SUPPORTED IN ACCORDANCE WITH THE NEC AND CABLE MANUFACTURER'S RECOMMENDATIONS. 5. ALL CONDUCTORS SHALL BE TAGGED AT BOTH ENDS OF THE CONDUCTOR, AT ALL PULL BOXES. J-BOXES, EQUIPMENT AND CABINETS AND SHALL BE IDENTIFIED WITH APPROVED PLASTIC TAGS (ACTION CRAFT. BRADY, OR APPROVED EQUAL). C. DISCONNECT SWITCHES: 1. DISCONNECT SWITCHES SHALL BE HEAVY DUTY, DEAD -FRONT. QUICK -MAKE, QUICK -BREAK, EXTERNALLY OPERABLE. HANDLE LOCKABLE AND INTERLOCK WITH COVER IN CLOSED POSITION, RATING AS INDICATED, UL LABELED FURNISHED IN NEMA 3R ENCLOSURE, SOUARE-D OR ENGINEER APPROVED EOUAL D. CHEMICAL ELECTROLYTIC GROUNDING SYSTEM: 1. INSTALL CHEMICAL GROUNDING AS REQUIRED. THE SYSTEM SHALL BE ELECTROLYTIC MAINTENANCE FREE ELECTRODE CONSISTING OF RODS WITH A MINIMUM #2 AWG CU EXOTHERMICALLY WELDED PIGTAIL. PROTECTIVE BOXES, AND BACKFILL MATERIAL. MANUFACTURER SHALL BE LYNCOLE XIT GROUNDING ROD TYPES K2 -(•)CS OR K2L-(•)CS (•) LENGTH AS REOUIRED. 2. GROUND ACCESS BOX SHALL BE A POLYPLASTIC BOX FOR NON -TRAFFIC APPUCATIONS, INCLUDING BOLT DOWN FLUSH COVER WITH -BREATHER" HOLES, XIT MODEL #XB-22. ALL DISCONNECT SWITCHES AND CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED LAMICOID NAMEPLATES INDICATING EOUIPMENT CONTROLLED, BRANCH CIRCUITS ID NUMBERING. AND THE ELECTRICAL POWER SOURCE. 3. BACKFILL MATERIAL SHALL BE LYNCONITE AND LYNCOLE GROUNDING GRAVEL E. STSILM GROUNDING: 1. ALL GROUNDING COMPONENTS SHALL BE TINNED AND GROUNDING CONDUCTOR SHALL BE #2 AWG BARE, SOUD, TINNED, COPPER. ABOVE GRADE GROUNDING CONDUCTORS SHALL BE INSULATED WHERE NOTED. 2. GROUNDING BUSES SHALL BE BARE. TINNED, ANNEALED COPPER BARS OF RECTANGULAR CROSS SECTION. STANDARD BUS BARS MGB, SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. THEY SHALL NOT BE FABRICATED OR MODIFIED IN THE FIELD. ALL GROUNDING BUSES SHALL BE IDENTIFIED WITH MINIMUM 3/4" LETTERS BY WAY OF STENCILING OR DESIGNATION PLATE. 3. CONNECTORS SHALL BE HIGH -CONDUCTIVITY, HEAVY DUTY, USTED AND LABELED AS GROUNDING CONNECTORS FOR THE MATERIALS USED. USE TWO -HOLE COMPRESSION LUGS WITH HEAT SHRINK FOR MECHANICAL CONNECTIONS. INTERIOR CONNECTIONS USE TWO -HOLE COMPRESSION LUGS WITH INSPECTION WINDOW AND CLEAR HEAT SHRINK. 4. EXOTHERMIC WELDED CONNECTIONS SHALL BE PROVIDED IN KIT FORM AND SELECTED FOR THE SPECIFIC TYPES. SIZES, AND COMBINATIONS OF CONDUCTORS AND OTHER ITEMS TO BE CONNECTED. 5. GROUND RODS SHALL BE COPPER -CLAD STEEL WITH HIGH -STRENGTH STEEL CORE AND ELECTROLYTIC -GRADE COPPER OUTER SHEATH. MOLTEN WELDED TO CORE. 5/8"x10'-0". ALL GROUNDING RODS SHALL BE INSTALLED WITH INSPECTION SLEEVES. 6. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS IN COMPLIANCE WITH THE AT&T SPECIFICATIONS AND NEC. THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULLBOXES, DISCONNECT SWITCHES, STARTERS, AND EQUIPMENT CABINETS. F. OTHER MATERIALS: 6. THE CONTRACTOR SHALL PROVIDE OTHER MATERIALS. THOUGH NOT SPECIFICALLY DESCRIBED. WHICH ARE REQUIRED FOR A COMPLETELY OPERATIONAL SYSTEM AND PROPER INSTALLATION OF THE WORK. 7. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REOUIRED BY NEC. G. PANELS AND LOAD CENTERS: 1. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN. PART 3 - EXECUTION 3.1 GENERAL A. ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. EOUIPMENT SHALL BE TIGHTLY COVERED AND PROTECTED AGAINST DIRT OR WATER, AND AGAINST CHEMICAL OR MECHANICAL INJURY DURING INSTALLATION AND CONSTRUCTION PERIODS. 3.2 LABOR AND WORKMANSHIP: A. ALL LABOR FOR THE INSTALLATION OF MATERIALS AND EQUIPMENT FURNISHED FOR THE ELECTRICAL STSILM SHALL BE INSTALLED BY EXPERIENCED WIREMEN, IN A NEAT AND WORKMAN -LIKE MANNER. B. ALL ELECTRICAL EQUIPMENT SHALL BE ADJUSTED, ALIGNED AND TESTED BY THE CONTRACTOR AS REOUIRED TO PRODUCE THE INTENDED PERFORMANCE. C. UPON COMPLETION OF WORK, THE CONTRACTOR SHALL THOROUGHLY CLEAN ALL EXPOSED EQUIPMENT. REMOVE ALL LABELS AND ANY DEBRIS, CRATING OR CARTONS AND LEAVE THE INSTALLATION FINISHED AND READY FOR OPERATION. 3.3 COORDINATION: A. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ELECTRICAL ITEMS WITH THE OWNER -FURNISHED EOUIPMENT DELIVERY SCHEDULE TO PREVENT UNNECESSARY DELAYS IN THE TOTAL WORK. 3.4 INSTALLATION: A. CONDUIT: 1. ALL ELECTRICAL WIRING SHALL BE INSTALLED IN CONDUIT AS SPECIFIED. NO CONDUIT OR TUBING OF LESS THAN 3/4 INCH TRADE SIZE. 2. PROVIDE RIGID PVC SCHEDULE 80 CONDUITS FOR ALL RISERS, RMC OTHERWISE NOTED. EMT MAY BE INSTALLED FOR EXTERIOR CONDUITS WHERE NOT SUBJECT TO PHYSICAL DAMAGE. 3. INSTALL SCHEDULE 40 PVC CONDUIT WITH A MINIMUM COVER OF 24" UNDER ROADWAYS, PARKING LOTS. STREETS. AND ALLEYS. CONDUIT SHALL HAVE A MINIMUM COVER OF 18" IN ALL OTHER NON -TRAFFIC APPLICATIONS (REFER TO 2008 NEC. TABLE 300.5). 4. USE GALVANIZED FLEXIBLE STEEL CONDUIT WHERE DIRECT CONNECTION TO EQUIPMENT WITH MOVEMENT, VIBRATION. OR FOR EASE OF MAINTENANCE. USE LIQUID TIGHT. FLEXIBLE METAL CONDUIT FOR OUTDOOR APPLICATIONS. INSTALL GALVANIZED FLEXIBLE STEEL CONDUIT AT ALL POINTS OF CONNECTION TO EQUIPMENT MOUNTED ON SUPPORT TO ALLOW FOR EXPANSION AND CONTRACTION. 5. A RUN OF CONDUIT BETWEEN BOXES OR EQUIPMENT SHALL NOT CONTAIN MORE THAN THE EQUIVALENT OF THREE QUARTER -BENDS. CONDUIT BEND SHALL BE MADE WITH THE UL USTED BENDER OR FACTORY 90 DEGREE ELBOWS MAY BE USED. 6. FIELD FABRICATED CONDUITS SHALL BE CUT SQUARE WITH A CONDUIT CUTTING TOOL AND REAMED TO PROVIDE A SMOOTH INSIDE SURFACE. 7. PROVIDE INSULATED GROUNDING BUSHING FOR ALL CONDUITS. 8. CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL CONDUITS DURING CONSTRUCTION. TEMPORARY OPENINGS IN THE CONDUIT SYSTEM SHALL BE PLUGGED OR CAPPED TO PREVENT ENTRANCE OF MOISTURE OR FOREIGN MATTER. CONTRACTOR SHALL REPLACE ANY CONDUITS CONTAINING FOREIGN MATERIALS THAT CANNOT BE REMOVED. 9. ALL CONDUITS SHALL BE SWABBED CLEAN BY PUWNG AN APPROPRIATE SIZE MANDREL THROUGH THE CONDUIT BEFORE INSTALLATION OF CONDUCTORS OR CABLES. CONDUIT SHALL BE FREE OF DIRT AND DEBRIS. 10. INSTALL PULL STRINGS IN ALL CLEAN EMPTY CONDUITS. IDENTIFY PULL STRINGS AT EACH END. 11. INSTALL 2" HIGHLY VISIBLE AND DETECTABLE TAPE 12" ABOVE ALL UNDERGROUND CONDUITS AND CONDUCTORS. 12. CONDUITS SHALL BE INSTALLED IN SUCH A MANNER AS TO INSURE AGAINST COLLECTION OF TRAPPED CONDENSATION. 13. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS TO ALLOW FOR RACEWAYS AND CABLES TO BE ROUTED THROUGH THE BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS. SLEEVES AND/OR PENETRATIONS IN FIRE RATED CONSTRUCTION SHALL BE EFFECTIVELY SEALED WITH FIRE RATED MATERIAL WHICH SHALL MAINTAIN THE FIRE RATING OF THE WALL OR STRUCTURE. ARE STOPS AT FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER. SMOKE. FIRE. AND FUMES. ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE. 1. ALL POWER WIRING SHALL BE COLOR CODED AS FOLLOWS: TIFSCRIPTION 20A8/E A K 40/120 VOI T SY5TFM4 PPHASE B RED PHASE C BLUE NEUTRAL WHITE GROUNDING GREEN 2. SPLICES SHALL BE MADE ONLY AT OUTLETS, JUNCTION BOXES, OR ACCESSIBLE RACEWAY CONDUITS APPROVED FOR THIS PURPOSE. 3. PULUNG LUBRICANTS SHALL BE UL APPROVED. CONTRACTOR SHALL USE NYLON OR HEMP ROPE FOR PUWNG CONDUCTOR OR CABLES INTO THE CONDUIT. 4. CABLES SHALL BE NEATLY TRAINED. WITHOUT INTERLACING, AND BE OF SUFFICIENT LENGTH IN ALL BOXES & EQUIPMENT TO PERMIT MAKING A NEAT ARRANGEMENT. CABLES SHALL BE SECURED IN A MANNER TO AVOID TENSION ON CONDUCTORS OR TERMINALS. CONDUCTORS SHALL BE PROTECTED FROM MECHANICAL INJURY AND MOISTURE. SHARP BENDS OVER CONDUIT BUSHINGS IS PROHIBITED. DAMAGED CABLES SHALL BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE. C. DISCONNECT SWITCHES: 1. INSTALL DISCONNECT SWITCHES LEVEL AND PLUMB. CONNECT TO WIRING STS1 LM AND GROUNDING SYSTEM AS INDICATED. D. GROUNDING: 1. ALL METALLIC PARTS OF ELECTRICAL EOUIPMENT WHICH DO NOT CARRY CURRENT SHALL BE GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF THE BUILDING MANUFACTURER, AT&T GROUNDING AND BONDING STANDARDS TP-76416, ND-00135, AND THE NATIONAL ELECTRICAL CODE. 2. PROVIDE ELECTRICAL GROUNDING AND BONDING SYSTEM INDICATED WITH ASSEMBLY OF MATERIALS, INCLUDING GROUNDING ELECTRODES, BONDING JUMPERS AND ADDITIONAL ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION. 3. ALL GROUNDING CONDUCTORS SHALL PROVIDE A STRAIGHT DOWNWARD PATH TO GROUND WITH GRADUAL BEND AS REQUIRED. GROUNDING CONDUCTORS SHALL NOT BE LOOPED OR SHARPLY BENT. ROUTE GROUNDING CONNECTIONS AND CONDUCTORS TO GROUND IN THE SHORTEST AND STRAIGHTEST PATHS POSSIBLE TO MINIMIZE TRANSIENT VOLTAGE RISES. 4. BUILDINGS AND/OR NEW TOWERS GREATER THAN 75 FEET IN HEIGHT AND WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP. TOWERS, AND WATER TOWERS GROUNDING RING. TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 AWG COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING STSILM, THE BUILDING STEEL COLUMNS. UGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). SEE STANDARD 6.3.2.2. 5. TIGHTEN GROUNDING AND BONDING CONNECTORS, INCLUDING SCREWS AND BOLTS, IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED TORQUE TIGHTENING VALUES FOR CONNECTORS AND BOLTS. WHERE MANUFACTURER'S TORQUING REQUIREMENTS ARE NOT AVAILABLE, TIGHTEN CONNECTIONS TO COMPLY WITH TIGHTENING TORQUE VALUES SPECIFIED IN UL TO ASSURE PERMANENT AND EFFECTIVE GROUNDING. 6. CONTRACTOR SHALL VERIFY THE LOCATIONS OF GROUNDING TIE -IN -POINTS TO THE EXISTING GROUNDING SYSTEM. ALL UNDERGROUND GROUNDING CONNECTIONS SHALL BE MADE BY THE EXOTHERMIC WELD PROCESS AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 7. ALL GROUNDING CONNECTIONS SHALL BE INSPECTED FOR TIGHTNESS. EXOTHERMIC WELDED CONNECTIONS SHALL BE APPROVED BY THE INSPECTOR HAVING JURISDICTION BEFORE BEING PERMANENTLY CONCEALED. 8. APPLY CORROSION -RESISTANT FINISH TO FIELD CONNECTIONS AND PLACES WHERE FACTORY APPUED PROTECTIVE COATINGS HAVE BEEN DESTROYED. USE KOPR-SHIELD ANTI -OXIDATION COMPOUND ON ALL COMPRESSION GROUNDING CONNECTIONS. 9. A SEPARATE, CONTINUOUS, INSULATED EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ALL FEEDER AND BRANCH CIRCUITS. 10. BOND ALL INSULATED GROUNDING BUSHINGS WITH A BARE #6 AWG GROUNDING CONDUCTOR TO A GROUND BUS. 11. DIRECT BURIED GROUNDING CONDUCTORS SHALL BE INSTALLED AT A NOMINAL DEPTH OF 36" MINIMUM BELOW GRADE, OR 6" BELOW THE FROST UNE, USE THE GREATER OF THE TWO DISTANCES. 12. ALL GROUNDING CONDUCTORS EMBEDDED IN OR PENETRATING CONCRETE SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUIT. 13. THE INSTALLATION OF CHEMICAL ELECTROLYTIC GROUNDING SYSTEM IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REMOVE SEALING TAPE FROM LEACHING AND BREATHER HOLES. INSTALL - PROTECTIVE BOX FLUSH WITH GRADE. • 14. DRIVE GROUND RODS UNTIL TOPS ARE A MINIMUM DISTANCE OF 36" DEPTH OR 6" BELOW FROST LINE. USING THE GREATER OF THE TWO DISTANCES. 15. IF COAX ON THE ICE BRIDGE IS MORE THAN 6 FT. FROM THE GROUNDING BAR AT THE BASE OF THE TOWER. A SECOND GROUNDING BAR WILL BE NEEDED AT THE END OF THE ICE BRIDGE. TO GROUND THE COAX CABLE GROUNDING KITS AND IN -LINE ARRESTORS. 16. CONTRACTOR SHALL REPAIR, AND/OR REPLACE. EXISTING GROUNDING STSILM COMPONENTS DAMAGED DURING CONSTRUCTION AT THE CONTRACTORS EXPENSE. 3.5 ACCEPTANCE TESTING: A. CERTIFIED PERSONNEL USING CERTIFIED EOUIPMENT SHALL PERFORM REQUIRED TESTS AND SUBMIT WRITTEN TEST REPORTS UPON COMPLETION. B. WHEN MATERIAL AND/OR WORKMANSHIP IS FOUND NOT TO COMPLY WITH THE SPECIFIED REQUIREMENTS. THE NON -COMPLYING ITEMS SHALL BE REMOVED FROM THE PROJECT SITE AND REPLACED WITH ITEMS COMPLYING WITH THE SPECIFIED REQUIREMENTS PROMPTLY AFTER RECEIPT OF NOTICE FOR NON-COMPLIANCE. C. TEST PROCEDURES: 1. ALL FEEDERS SHALL HAVE INSULATION TESTED AFTER INSTALLATION, BEFORE CONNECTION TO DEVICES. THE CONDUCTORS SHALL TEST FREE FROM SHORT CIRCUITS AND GROUNDS. TESTING SHALL BE FOR ONE MINUTE USING 1000V DC. PROVIDE WRITTEN DOCUMENTATION FOR ALL TEST RESULTS. 2. PRIOR TO ENERGIZING CIRCUITRY, TEST WIRING DEVICES FOR ELECTRICAL CONTINUITY AND PROPER POLARITY CONNECTIONS. 3. MEASURE AND RECORD VOLTAGES BETWEEN PHASES AND BETWEEN PHASE CONDUCTORS AND NEUTRALS. SUBMIT A REPORT OF MAXIMUM AND MINIMUM VOLTAGES. 4. PERFORM GROUNDING TEST TO MEASURE GROUNDING RESISTANCE OF GROUNDING SYSTEM USING THE IEEE STANDARD 3-POINT "FALL -OF -POTENTIAL" METHOD. PROVIDE PLOTTED TEST VALUES AND LOCATION SKETCH. NOTIFY THE ENGINEER IMMEDIATELY IF MEASURED VALUE IS OVER 5 OHMS. 4/8'-D_D4? Rdr, . Rsf /,.a D at&t mobility 41asTec Network Solutions /I�_ GPD GROUP Professional Corporation 520 South Maln Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 PROJECT NO: 2018723.04.75142.01 DRAWN BY: CJM CHECKED BY: JG 0 B 05/21/18 03/22/18 ISSUED FOR CONSTRUCTION ISSUED FOR REVIEW IDIPIRE&: 02/03/2020 1 EE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 1-5 & 1-405 10032276 5711 S 152ND ST TUKWILA, WA 98188 LTE - ROOFTOP SHEET TITLE ELECTRICAL NOTES SHEET NUMBER E-2 ELECTRICAL NOTES JUN 22. 2018 1 Community Development