HomeMy WebLinkAboutPermit PL18-0065 - TMOBILE - WIRELESS FACILITYTMOBILE
3523049037
PARENT FILE
PL18-0065
THIS FILE
L18-0076
WIRELESS FACILITY/TYPE 1
City of Tukwila
Allan Ekberg, Mayor
Department of Community Development - Jack Pace, Director
October 18, 2018
NOTICE OF DECISION
TO: Weston Jorgenson, Powder River Development Services LLC, OBO T-Mobile
King County Solid Waste, Owner
King County Assessor, Accounting Division
Agencies with Jurisdiction
All Parties of Record
This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit
approval.
I. PROJECT INFORMATION
Project File Number: L18-0076; PL18-0071
Applicant: Weston Jorgenson
Type of Permit Applied for: Type 1 Wireless Facilities Permit
Project Description: The applicant is proposing modifying antenna equipment on an existing
monopole and, at antenna level, remove two (2) SBNHH-1D65C-SR antennas,
two (2) TMBXX-6516-A2M, eight (8) diplexers, two (2) FRLB, two (2) FRIG, two
(2) FHFB, and three (3) t-arm sector frames and install one (1) low profile
antenna platform, two (2) AAFIA antennas, two (2) FFHH-65C-R3, two (2)
AHLOA, and relocate all other equipment to new low -profile antenna sector
platform. At ground level, remove one (1) ultrasite cabinet, two (2) FSMF, and
three (3) FBBC and install one (1) FCOA, two (2) AMOB, three (3) ABIA, one (1)
ASIA, one (1) ABIL, and one (1) ASIK.
The project also qualifies as an Eligible Facilities Modification under § 6409 of
the FCC's Spectrum Act, which requires the City to approve any eligible facilities
request for a modification of an existing tower or base station that does not
substantially change the physical dimensions of such tower or base station. This
proposal is not considered a substantial change under the Tukwila Municipal
Code 18.58.200.7, and falls within the guidelines for an eligible facilities
modification.
Location: Parcel 3523049037- located at 18800 Orillia Rd South, Tukwila, WA 98188
Associated Files: PL18-0065
Comprehensive Plan Tukwila Valley South (TVS)
Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov
Designation/Zoning
District: Tukwila Valley South (TVS)
II. DECISION
SEPA Determination: The City SEPA Responsible Official has determined that this application does not require a
SEPA threshold determination because it is categorically exempt.
Decision on Substantive Permit: The Community Development Director has determined that the application for a
Wireless Telecommunication Facility does comply with applicable City and state code requirements and has
approved this application with the following condition.
1. The applicant must apply for a business license to operate the wireless facility at this location.
III. YOUR APPEAL RIGHTS
The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code §18.104.010.
Other land use applications related to this project may still be pending.
No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of
the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the
conditions which were imposed by the MDNS decision or the failure of the Department to impose additional
conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner.
A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King
County Superior Court from the Hearing Examiner's decision.
IV. PROCEDURES AND TIME FOR APPEALING
To appeal the Community Development Director decision on the Permit Application, a written notice of appeal
must be filed with the Department of Community Development within 14 days of the issuance of this Decision.
The requirements for such appeals are set forth in Tukwila Municipal Code Ch. 18.116. All appeal materials shall
be submitted to the Department of Community Development. Appeal materials MUST include:
1. The name of the appealing party.
2. The address and phone number of the appealing party; and if the appealing party is a corporation, association
or other group, the address and phone number of a contact person authorized to receive notices on the
appealing party's behalf.
3. A statement identifying the decision being appealed and the alleged errors in the decision, including any
specific challenge to an MDNS.
4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the
decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The
scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal.
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
5. Appeal fee per the current fee schedule, additional hourly charges may apply. In addition, all hearing examiner
costs will be passed through to the appellant.
V. APPEAL HEARINGS PROCESS
Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the
Hearing Examiner based on the information presented to the Community Development Director, who made the
original decision. No new evidence or testimony will be permitted during the appeal hearing. Parties will be
allowed to present oral argument based on the information presented to the Community Development Director
before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision.
Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant
to the procedures and time limitations set forth in RCW Ch. 36.70C. An appeal challenging a DNS, an MDNS or
an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in
Superior Court within such time limit, the Decision on this permit will be final. The City's decision to issue a DNS,
an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the
subject property.
VI. INSPECTION OF INFORMATION ON THE APPLICATION
Project materials including the application, any staff reports, and other studies related to the permits are available for
inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila,
Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Meredith
Sampson who may be contacted at (206)431-3661 for further information.
Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact
the King County Assessor's Office for further information regarding property tax valuation changes.
Dep
City
i
rt of Community Development
f Tukwila
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
City of Tukwila
Allan Ekberg, Mayor
Department of Community Development - Jack Pace, Director
Staff Report
PREPARED October 18, 2018
NOTIFICATION: Notification is not required for a Type 1 land use application.
FILE NUMBER: L18-0076; PL18-0065
APPLICANT: Weston Jorgenson, American Tower Corporation/T-Mobile c/o Powder River
Development Services, LLC Agent
PROPERTY OWNER: King County - Solid Waste
REQUEST:
Approval of a Type 1 Wireless Telecommunications Facilities Permit to modify
antenna equipment on an existing monopole and, at antenna level, remove two
(2) SBNHH-1D65C-SR antennas, two (2) TMBXX-6516-A2M, eight (8) dipiexers,
two (2) FRLB, two (2) FRIG, two (2) FHFB, and three (3) t-arm sector frames and
install one (1) low profile antenna platform, two (2) AAFIA antennas, two (2)
FFHH-65C-R3, two (2) AHLOA, and relocate all other equipment to new low -
profile antenna sector platform. At ground level, remove one (1) ultrasite
cabinet, two (2) FSMF, and three (3) FBBC and install one (1) FCOA, two (2)
AMOB, three (3) ABIA, one (1) ASIA, one (1) ABIL, and one (1) ASIK.
LOCATION: Parcel 3523049037- located at 18800 Orillia Rd South, Tukwila, WA 98188
ASSOCIATED PERMITS:
Electrical permits issued through the City of Tukwila will be required for
service alteration for any other electrical service work that is anticipated but not
noted on the plans, per article 85.12 (B), Washington electrical code. Building
and mechanical permits are required for scope of work stated on the submitted
plans.
SEPA
DETERMINATION: Exempt
COMPREHENSIVE PLAN Tukwila Valley South (TVS)
DESIGNATION:
ZONE DESIGNATION: Tukwila Valley South (TVS)
STAFF: Meredith Sampson, Assistant Planner
ATTACHMENTS: Project Plans for Permit L18-0076
Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov
Page 2
• •
Vicinity/Site Information
FINDINGS
Project Description
The applicant is proposing modifying antenna equipment on an monopole by, at antenna level,
removing two (2) SBNHH-1D65C-SR antennas, two (2) TMBXX-6516-A2M, eight (8) diplexers, two (2) FRLB, two
(2) FRIG, two (2) FHFB, and three (3) T-arm sector frames and installing one (1) low profile antenna platform,
two (2) AAFIA antennas, two FFHH-65C-R3, two (2) AHLOA, and relocating all other equipment to new low -
profile antenna sector platform. At ground level, removing one (1) ultrasite cabinet, two (2) FSMF, and three (3)
FFBC. Installing one (1) FCOA, two (2) AMOB, three (3) ABIA, one (1) ASIA, one (1) ASIK.
The project also qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which
requires the City to approve any eligible facilities request for a modification of an existing tower or base station
that does not substantially change the physical dimensions of such tower or base station. This proposal is not
considered a substantial change under the Tukwila Municipal Code 18.58.200.7, and falls within the guidelines
for an eligible facilities modification.
Existing Development
This telecommunications facility is preexisting.
Surrounding Land Uses
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: Tukwi(aWA.gov
• Page 3
The property is zoned Tukwila Valley South (TVS). Surrounding parcels to the north, south and east of this parcel
are also zoned within the TVS zone. Interstate 5 runs to the west of this parcel, and parcels beyond that to the
west fall within the jurisdiction of SeaTac.
Background
In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.71) to the Zoning Code. The chapter provides
location and design requirements for the placement of WCF within the City of Tukwila. In 2016 the city adopted
amendments to this ordinance in compliance with the Federal Spectrum Act.
Location Selection
Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co -
locations and utilizing existing structures are favored over the development of new standalone WCF within the
City.
TABLE A
Type of Porcnit Required, Based on
Type of Wireless Communication Facility
Zonirg(1)
Type of Facility
Residential
Comrade
tndustrilal
Addlng antennas to
an existing tower a utiity
PQia
Type Uzi
Type 11:
Type 1(21
Eligible facilities
modification
Type t
Type t
Type 1
Utility pole co4locaton
Type 2
Type 2
Type 2
Concealed buirrmg
attached
Type 2(31
Type 21
Type 1
Nan -concealed builtng
adarhed
Type 2(4I
Type 2
Type 1
New lbws or height
adjustment request
Type 341
Type 3
Type 3
(1) Zoning for any private/public property or right-of-way
Residential — LDR, MDR, or HDR
Commercial — 0, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS
Industrial - LI, HI, MIC/L, or MIC/H
(2) Provided the height of the tower does not increase and the square footage of the enclosure area
does not increase.
(3) An applicant may request to install a non -concealed building attached facility, under TMC Section
18.58.150.
The applicant is proposing to modify the antenna equipment on an existing monopole by, at antenna level,
removing two (2) SBNHH-1D65C-SR antennas, two (2) TMBXX-6516-A2M, eight (8) diplexers, two (2) FRLB, two
(2) FRIG, two (2) FHFB, and three (3) T-arm sector frames and installing one (1) low profile antenna platform,
two (2) AAFIA antennas, two FFHH-65C-R3, two (2) AHLOA, and relocating all other equipment to new low -
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
Page 4
profile antenna sector platform. At ground level, removing one (1) ultrasite cabinet, two (2) FSMF, and three (3)
FFBC. Installing one (1) FCOA, two (2) AMOB, three (3) ABIA, one (1) ASIA, one (1) ASIK.
This site will be a modification to the property and falls within an Eligible Facilities Modification of the Tukwila
Municipal Code. Per TMC 18.58.200.7C.
Design Standards
The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below
indicates if the applicant's proposal complies with required standards.
Table 1 (See TMC 18.58.070 for further details)
General Requirements
Project
does
comply
Project
does
not
comply
Not
Applicable
Notes
1. Generators or other
devices which will create
noise must comply with TMC
8.22 regarding noise.
x
2.Business License
Requirement
X
Applicant will obtain a business license for the property
before modification
3.Only safety signage must
be placed on the WCF.
X
4. Accommodations for
parking for maintenance
personal must be provided.
X
This modification does not affect parking.
5. Towers shall either
maintain a galvanized steel
finish or be painted a neutral
color so as to reduce its
visual obtrusiveness.
X
6. The design of all buildings
and ancillary structures shall
use materials, colors,
textures, screening, and
landscaping that will blend
the tower facilities to the
natural setting and built
environment.
X
7. Antennas shall have the
same color scheme as the
structure they are located on.
X
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
• Page 5
8. WCF poles and towers
shall only have safety lights if
required by a government
agency.
X
9. No advertising is
permitted on WCF
X
10. Each service provider
shall be limited to an
equipment enclosure of 360
square feet.
X
Table 2 (See TMC 18.58.090 for further details)
Adding Antennas to
Existing WCF Towers
Development Standards
Project
Does
Comply
Project
Does
Not
Comply
Not
Applicable
Notes
1. The height must
not exceed the
height that was
approved at the
time of the original
monopole
construction
X
2. Antenna shall be
pained to match
the color scheme of
the tower
X
3. No limit to the
number of
antennas the may
be located at an
existing tower
X
4. Feed Tined and
coaxial cables are
located within the
tower
X
5. Any exposed feed
lines or cables will
be painted to
match the tower
X
6. Cabinet equipment
is located within
the equipment
enclosure
X
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
Page 6
7.
Setbacks will not
apply when
installing antennas
to an existing tower
X
CONCLUSIONS
1. The proposed modifications to the existing WCF will not significantly alter the conditions that currently exist
and will not be materially detrimental to the public welfare or injurious to property or improvements in the
vicinity.
2. As demonstrated in Table 1, the project meets all applicable development standards for a Type 1 WCF.
3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian
circulation, building or site design.
4. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan.
5. The project also qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which
requires the City to approve any eligible facilities request for a modification of an existing tower or base station
that does not substantially change the physical dimensions of such tower or base station.
RECOMMENDATIONS
The recommendation to the Director of Community Development is to approve this application for a Type 1
Wireless Telecommunications Facility permit with the following condition:
1. The applicant must apply for a business license to operate the wireless facility at this location.
INFORMATIONAL ITEMS
A City of Tukwila electrical permit is required for service alteration. A building and mechanical permit are
required for the site work.
Please note that the installation of an emergency power disconnect switch is required for Fire Department use.
If this cannot be done, please provide a non -ionizing electromagnetic exposure levels report for Roof Top
Modeling. Contact Don Tomaso at 206-971-8723 to get more information about permit requirements for the
power disconnect switch or non -ionizing electromagnetic report.
Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov
eitii of ufuoita
Department Of Community Development
AFFIDAVIT OF DISTRIBUTION
I, Shana Markstrom, HEREBY DECLARE THAT:
Notice of Application
X
Notice of Decision
Notice of Public Hearing
Notice of Public Meeting
Determination of Non-
Significance
Mitigated Determination of Non -
Significance
Determination of
Significance & Scoping
Notice
Short Subdivision Agenda
Notice of Application for
Shoreline Mgmt Permit
Shoreline Mgmt Permit
Board of Appeals Agenda
Packet
Board of Adjustment Agenda Packet
Official Notice
Notice of Action
Other:
Was mailed to each of the addresses listed/attached
on this 19TH day of OCTOBER, 2018
Project Name: TMOBILE
Project Number: PL18-0065
Associated File Number (s): L18-0076
Mailing requested by: MEREDITH SAMPSON
Mailer's signature:
C:\USERS\DCD-ADMIN\DOCUMENTS\iMAILINGSU FIDAVIT OF DISTRIRUTION.DOC
1J/ 2 T /Y1l•/ l'J3g2M111.1;
D.
USPS
1
IEMAIL
1,2
1
1
1
1
OWNER KC WASTEWATER TREATMENT ENVIRO PLANNING -OAP
APPLICANT
AGENT
AGENT
AGENT
AGENT
[HANDLING
KC ASSESSOR'S OFFICE ACCOUNTING DIVISION
CITY OF TUKWILA DEPARTMENT
TUKWILA HISTORICAL SOCIETY
TUKWILA HISTORICAL SOCIETY
1 NOD
2 STAFF REPORT
201 S JACKSON ST., MS KSC-N SEATTLE W 98104
me
WESTON.JORGENSON@POWERRIVERDEV.COM
500 4th AVE, RM# 709A SEATTLE W 98104 Christie.Most@kingcounty.gpv
ANA.LE@TUKWILAWA.GOV
tukwilahistsociety@tukwilahistory.or&
rcwieser@comcast.net
404,4S1 Powder River Development Services, LLC
408 S Eagle Road, Suite 200
Eagle, ID 83616
POWDER RIVER (208) 938-8844 office
(208) 938-8855 fax
Development Services, LLC www.powderriverdev.com
August 17, 2018
City of Tukwila
Department of Community Development
6300 Southcenter Blvd.
Tukwila, WA 98188
Subject: Type 1 Wireless Telecommunication Facilities Zoning Application
Site No: 414339 / SE03858A / Bow Lake
Site Address: 18700 Orillia Road South, Seattle, WA 98188
Parcel # 3523049037
Dear Community Development,
Powder River Development Services is representing American Tower Corporation (ATC) regarding the T-
Mobile network expansion project on an existing wireless communication facility in the City of Tukwila,
referenced above.
Scope of Work:
AT ANTENNA LEVEL: REMOVE (2) SBNHH-1D65C-SR ANTENNAS, (2) TMBXX - 6516- A2M, (8)
DIPLEXERS, (2) FRLB, (2) FRIG, (2) FHFB, AND (3) T-ARM SECTOR FRAMES AND INSTALL (1) LOW
PROFILE ANTENNA PLATFORM, (2) AAFIA ANTENNAS, (2) FFHH-65C-R3 AND (2) AHLOA.
RELOCATE ALL OTHER EQUIPMENT TO NEW LOW -PROFILE ANTENNA SECTOR PLATFORM.
AT GROUND LEVEL: REMOVE (1) ULTRASITE CABINET, (2) FSMF, AND (3) FBBC AND INSTALL (1)
FCOA, (2) AMOB, (3) ABIA, (1) ASIA, (1) ABIL, AND (1) ASIK
There will be no increase to the existing tower height and there will be no expansion to the existing
compound square footage, and therefore will not be a 'substantial change'. All work will be performed
within the guidelines/requirements of city code.
Enclosed Submittal Documents:
• (1) completed WCF application
• (1) WCF application checklist
• (4) sets of construction drawings
• (1) signed/notarized affidavit form
• (1) check of $319.74
Upon approval of our application please email me a copy of the approval documents
(Owen.Nasonpowderriverdev.com) and further instructions if necessary. With approval, I will move
forward with building permit process. If you have any question or need more information, please let me
know.
Resj ectfully,
Owen Nason
Powder River Development Services, LLC
208-501-7049
RECEIV0
AUG 27 Liii8
Commury
Development
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670
AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS
PERMISSION TO ENTER PROPERTY
STATE OF WASHINGTON
ss
COUNTY OF KING
The undersigned being duly sworn and upon oath states as follows:
1. 1 am the current owner of the property which is the subject of this application.
2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my
knowledge.
3. The application is being submitted with my knowledge and consent.
4. Owner grants the City, its employees, agents, engineers, contractors or other representatives the right to enter upon Owner's real
property, located at 18800 Orlllia Road South, Tukwila Washington for the purpose of application
review, for the limited time necessary to complete that purpose.
5. Owner agrees to hold the City harmless for any Toss or damage to persons or property occurring on the private property during
the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City.
6. Non -responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without
refund of fees.
EXECUTED at Se6/1/Q (city), _ (state), on M 2(! , 20 /7
(Print Name)
Anthony O. Wright, Director
(Addres$aclllties Management Division
(Phone Number
(Signatur
RECEIVED
AU6 27 21118
Community
Development
to me known to be the individual who
executed the foregoing instrument and acknowledged that he/sh signid the same as his/her voluntary act and deed for the uses and
purposes mentioned therein.
On this day personally appeared before me
SUBSCRIBED AND SWORN TO BEFORE ME ON THIS '40 DAY OF
glQ
Y PUBL C in and frr th State of Washington
residing at
My Commission expires on
1depIsmre\City Common \reri`KvbyUuly 26 2015%.W'ireless Communicannn Pacility06-04-1S do:x
r20/7
1�
414339 5E03858A
COMPLETE APPLICATION CHECKLIST
The materials listed below must be submitted with your application. You may request a waiver from items on the
checklist that are not applicable to your project. Please discuss this waiver request with City staff either at a pre -
application meeting or at the time of application submittal. Application review will not begin until it is determined
to be complete. Within 28 days of receiving your application, City staff will determine if it is complete based on the
attached checklist. If not complete City staff will mail you a letter outlining what additional information is needed.
If you do not submit requested materials within 90 days from the City's request for additional information the City
may cancel your application.
Check items
submitted
with
application
Information Required. - Additional materials may be required.
APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities.
X
I. Application Checklist (1 copy) indicating items submitted with application.
X
2. Completed Application Form and drawings (5 copies).
X
3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site
map, architectural elevations, method of attachment, proposed screening, location of proposed
antennas, and all other information which accurately depicts the proposed project. Minimum size
is 8 1/2" x II". Plans shall be no greater than 24" x 36".
X
4. Application Fee: See Land Use Fee Schedule.
X
5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property
(1 copy attached).
N/A
6. SEPA Environmental Checklist. SEPA is not required when the facility:
i) Is a microcell and is to be attached to an existing structure that is not a residence or school and
does not contain a residence or a school;
ii) Includes personal wireless antennas, other than a microcell, and is to be attached to an existing
structure (that may be an existing tower) that is not a residence or school and does not contain a
residence or school, and the existing structure to which it is to be attached is located in a
commercial, industrial, manufacturing, forest or agriculture zone; or
iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a
commercial, industrial, manufacturing, forest, or agricultural zone.
X
7. A letter from the applicant describing the proposed project and describing compliance with the
City's Code requirements stated in TMC Section 18.58. Include statement whether the proposal is
considered a "substantial change" or not as defined by the FCC rules and TMC Section 18.58.200.
N/A
8. Sensitive Area studies and proposed mitigation (if required).
N/A
9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating
compliance with TMC Section 8.22, "Noise".
If the application requires a Type 2 review these additional items are needed:
10. Four sets of photo simulations that depict the existing and proposed view of the proposed facility;
11. Materials board for the screening material;
12. Landscaping plan;
13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal
requirements for allowed emissions;
14. if the facility is located within a residential zone, a report from a radio frequency engineer
explaining the need for the proposed wireless communication facility at that location. Additionally,
W:\@SHAREPOINT FOLDER RESTRUCTURE \Refcrcncc\APPLICATIONS - Land Use Apps & Handouts\CURRENT LAND USE APPI.ICATIONS\DRAFT Wireless Communication
Facility.docx
414339 SE03858A
Check items
submitted
with
application
Information Required. - Additional materials may be required
the applicant shall provide detailed discussion on why the wireless communication facility cannot be
located within a commercial or industrial zone.
If the application requires a Type 3 review these additional items are needed:
15. A narrative responding to the criteria at TMC Section 18.58.060.
16. The radio frequency engineer report shall include a discussion of the information required under
TMC Section 18.58.070. The report shall also explain why a tower must be used instead of any of
the other location options outlined in Table A.
17. Engineering Plans for the proposed tower.
18. A vicinity map depicting the proposed extent of the service area.
19. A graphic simulation showing the appearance of the proposed tower and ancillary structures and
ancillary facilities from five points within the impacted vicinity. Such points are to be mutually
agreed upon by the Director of DCD and applicant. All plans and photo simulations shall include the
maximum build -out of the proposed facility.
20. Evidence of compliance with Federal Aviation Administration (FAA) standards for height and
lighting and certificates of compliance from all affected agencies.
21. Evidence that the tower has been designed to meet the minimum structural standards for wireless
communication facilities for a minimum of three providers of voice, video or data transmission
services, including the applicant, and including a description of the number and types of antennas the
tower can accommodate.
PUBLIC NOTICE MATERIALS: (Necessary for Type 3)
22. Payment of notice board fee (see Land Use Fee schedule) to FastSigns Tukwila OR provide a 4' x 4'
public notice board on site within 14 days of the Department determining that a complete application has
been received (see Public Notice Sign Specifications Handout).
23. Pay the fee as established by the Land Use Fee Schedule for generating mailing labels; OR provide
an excel spreadsheet of mailing labels for all property owners and tenants (residents and businesses)
within 500 feet of the subject property. Each unit in multiple family buildings e.g. apartments, condos,
trailer parks --must be included.
Once your project is assigned to a planner, you will be required to provide an electronic copy of the
mailing label spreadsheet in the following format: Name, Street Address, City St Zip, with each of these
fields as an individual column:
Name
Street Address
City, St, Zip
Mr. Smith
1234 Park Ave S
Tukwila WA 98188
PLEASE NOTE: Regardless of whether you pay the City to generate the mailing labels or you
provide them, there is an additional fee for postage and material as listed under Public Notice
Mailing Fee on the Land Use Fee Schedule. Payment of this fee is due prior to issuance of the
decision and you will receive a separate bill for this fee.
24. If providing own labels, include King County Assessor's map(s) which sho
property within 500 ft. of the subject lot.
99 9
'1- tab
AUG 27 2018
Commun y
Development
W:\CiSHAREPOINT FOLDER RESTRUCTURE\Rcfcrcnce\APPLICATIONS - Land Use Apps & Handouts\CURRENT LAND USE APPLICATIONS\DRAFT Wireless Communication
Facility.docx
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670
414339 SE03858A
WIRELESS TELE-
COMMUNICATION
FACILITIES
APPLICATION
FOR STAFF USE ONLY
Planner:
File Number: L1y_ (5
Application Complete Date:
Project File Number: 4JJ _ Oat
Application Incomplete Date:
Other File Numbers:
NAME OF PROJECT/DEVELOPMENT: T-Mobile cell tower mod 414339 SE03858A
BRIEF DESCRIPTION OF PROJECT: Replace antenna equipment on existing cell tower. L700
CIRCLE TYPE :
TYPE2 TYPE3
Public Hearing Notices
and Hearing Examiner
Fees Apply.
LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and
subdivision, access street, and nearest intersection.
18800 Orilla Road South, Tukwila, WA 98188
LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement).
3523049037
DEVELOPMENT COORDINATOR :
AUG 27 2U18
Commur'.v
Development
The individual who:
• has decision making authority on behalf of the owner/applicant in meetings with City staff,
• has full responsibility for identifying and satisfying all relevant and sometimes overlapping development
standards, and
• is the primary contact with the City, to whom all notices and reports will be sent.
Name: American Tower Corporation / T-Mobile c/o Powder River Development Services, LLC Agent: Owen Nason
A uth Eagle Road, Ste 200 Eagle, ID 83616
Phone: 262-385-3175
E-mail: owen.nason@powderriverdev.com
Signature:
Date: 3/27/2018
W:\@SHAREPOINT FOLDER RESTRUCTURE\Reference\APPLICATIONS - Land Use Apps & Handouts\CURRENT LAND USE APPLICATIONS\DRAFT Wireless Communication
Facility.docx
T • •Mobile•
SITE INFORMATION
TOWER MANAGER:
AMERICAN TOWER
10 PRESIDENTIAL WAY
WOBURN, MA 01801
SITE ADDRESS: 18700 ORIWA RD. S
SEATTLE, WA 98188
COUNTY: KING
LATITUDE:
LONGITUDE:
GROUND ELEVATION:
OCCUPANCY TYPE:
ZONING JURISDICTION:
ZONING CODE:
PARCEL NUMBER:
POWER PROVIDER:
TELCO PROVIDER:
47.43322'
—122.26966'
277' AMSL
UNMANNED
CITY OF TUKWILA
TVS
3523049037
PUGET SOUND ENERGY
CENTURYLINK
CONTACT INFORMATION
A&E SERVICES:
POWDER RIVER ENGINEERING SERVICES, LLC.
408 S. EAGLE ROAD, SUITE 200
EAGLE, ID 83616
CONTACT: TODD HILL
PHONE: 406.595.2233
EMAIL: todd.hillOpowderriverdev.com
SITE ACQUISITION:
POWDER RIVER DEVELOPMENT SERVICES, LLC.
408 S. EAGLE ROAD, SUITE 200
EAGLE, ID 83616
CONTACT: OWEN NASON
PHONE: 208.938.8844
EMAIL: owen.nasonOpowderriverdev.com
APPLICANT:
T—MOBILE WEST LLC
19807 NORTH CREEK PKWY
BOTHELL, WA 98011
CONTACT: MICHAEL REED
PHONE: 425-753-0525
EMAIL: MIKE.REED1610T—MOBILE.COM
TOWER CONTACT:
AMERICAN TOWER
10 PRESIDENTIAL WAY
WOBURN, MA 01801
CONTACT: SCOTT ALPHA
PHONE: 208.972.9969
EMAIL: scott.alphaOomericantower.com
ATC ASSET #:
414339
SITE NAME:
BOW LAKE TRANSFER/ USWES
SITE NUMBER:
SE03858A
FILE NAME:
414339 SE03858A L700 FCD REV 0 081718
LOCATION:
18700 ORILLIA RD. S, SEATTLE, WA 98188
47.43322, -122.26966
60' MONOPOLE
L700
VICINITY MAP
SITE PHOTO
Bryn Mawr
)M
Shorewood Boulevard Park*.
t5kyway
N! Renton
Burien ,
sTa I r.vrila'�
E
2, 1
� ��2
122.269676 ut
Kent
East Rentoi
Highlands
4.
NOT TO SCALE.I
CAL':
DRIVING DIRECTIONS
DIRECTIONS FROM SEATAC INTERNATIONAL AIRPORT:
DEPART AIRPORT (SOUTH). TAKE RAMP RIGHT FOR WA-518 EAST TOWARD SEATTLE / TACOMA. TAKE RAMP RIGHT FOR 1-5 SOUTH TOWARD
PORTLAND / TACOMA. 1-5 SOUTH TAKE THE S. 1B8TH ST EXIT (EXIT 152). STAY LEFT CROSS UNDER 1-5 PROCEEDING EAST. TAKE 2ND
LEFT AFTER 1-5 OVER PASS. DRIVE NORTH INTO TRANSFER STATION COMPLEX. SITE IS LOCATED ON LEFT HAND SIDE. LOCK COMBO
CODE 0715. THIS SITE IS EQUIPPED WITH THE CYBERLOCK SO ACCESS TO EQUIPMENT REQUIRES ESCORT IF PERSONNEL DOES NOT HAVE
OWN KEY.
APPLICABLE CODES
BUILDING CODE 2015 IBC
ELECTRICAL CODE 2017 NEC
RECEIVED
AUG 272018
Community
Development
DRAWING INDEX
SHEET NO.
DESCRIPTION
REV
T-1
TITLE SHEET
0
GN-1
GENERAL NOTES
0
GN-2
GENERAL NOTES
0
C-1
SITE PLAN
0
C-2
ELEVATIONS
0
C-3
ANTENNA PLANS
0
C-3.1
RFDS
0
C-4
EQUIPMENT DETAILS
0
C-5
EQUIPMENT DETAILS
0
C-6
EQUIPMENT DETAILS
0
C-7
CABINET DETAILS
0
G-1
GROUNDING PLANS
0
G-2
GROUNDING DETAILS
0
SCOPE OF WORK
RFDS VERSION 6.4 05/24/18
AT ANTENNA LEVEL, REMOVE (2) SBNHH-1D65C—SR ANTENNAS, (2)
TMBXX-6516—A2M, (8) DIPLEXERS, (2) FRLB, (2) FRIG, (2) FHFB, AND (3)
T—ARM SECTOR FRAMES AND INSTALL (1) LOW PROFILE ANTENNA PLATFORM
(2) AAFIA ANTENNAS, (2) FFHH-65C—R3 AND (2) AHLOA. RELOCATE ALL
OTHER EQUIPMENT TO NEW LOW PROFILE ANTENNA SECTOR PLATFORM.
AT GROUND LEVEL, REMOVE (1) ULTRASITE CABINET (2) FSMF, AND (3)
FBBC AND INSTALL (1) FCOA, (2) AMOB, (3) ABIA, (1) ASIA, (1) ABIL, (1)
ASIK.
T
• •Mobile
•
A
AMERICAN TOWER°
Alliii!, lik
POWDER RIVER
Engineering Services, LLC
www.powderriverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
B
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
R 1 T.', REGISTERED
\\/ ARCHITECT,41
GLENN WALKER
STATE OF WASHINGTON
THESE PUNS AND SPECIFICATIONS. AS INSTRUMENTS OF SERVICE. ARE
AND SHALL REWJN THE PROPERTY OF POWDER RIVER DEVELOPMENT
SERVICES. LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE
ARE IXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL
NOT BE USED BY ANY PERSON OR ENTRY ON OTHER PROJECTS
WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
TITLE SHEET
SHEET NUMBER:
T-1
GENERAL NOTES
1.GENERAL NOTES AND TYPICAL DETAILS SHALL APPLY TO ALL PARTS OF THE JOB
EXCEPT WHERE THEY MAY CONFLICT WITH DETAILS AND NOTES ON OTHER SHEETS.
WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR
CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED
SUBJECT TO REVIEW BY THE ENGINEER.
2.WORK SHALL CONFORM TO THE REQUIREMENTS, AS AMENDED TO DATE, OF THE
LATEST EDITION OF THE BUILDING CODE AND ALL OTHER LOCAL, STATE AND
FEDERAL REGULATIONS.
3.OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING
DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE
ENGINEER PRIOR TO PROCEEDING WITH ANY WORK INVOLVED.
4.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS
GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY.
WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE
REPORTED OT THE ENGINEER SO THAT THE PROPER REVISION MAY BE MADE.
MODIFICATIONS OF CONSTRUCTION DETAILS SHALL NOT BE MADE WITHOUT THE
WRITTEN APPROVAL OF THE ENGINEER.
5.THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE
CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY
RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND
PROCEDURES INCLUDING BUT NOT LIMITED TO BRACING,TEMPORARY SUPPORTS AND
SHORING. OBSERVATION VISITS TO THE SITE BY FIELD REPRESENTATIVES OF THE
ENGINEER SHALL NOT INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OR THE
CONSTRUCTION PROCEDURES. ANY SUPPORT SERVICES PERFORMED BY THE
ENGINEER DURING THE CONSTRUCTION SHALL BE DISTINGUISHED FROM
CONSTRUCTION AND DETAILED INSPECTION SERVICES WHICH ARE FURNISHED BY
OTHERS. THESE SUPPORT SERVICES PERFORMED BY THE ENGINEER, WHETHER OF
MATERIAL OR WORK, ARE FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL
AND IN ACHIEVING CONFORMANCE WITH CONTRACT DOCUMENTS, BUT DO NOT
GUARANTEE CONTRACTORS PERFORMANCE AND SHALL NOT BE CONSTRUED AS
SUPERVISION OF CONSTRUCTION. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS
TO MAINTAIN AND ENSURE THE INTEGRITY OF THE STRUCTURE DURING
CONSTRUCTION. NEITHER THE OWNER NOR ENGINEER WILL ENFORCE SAFETY
MEASURES OR REGULATIONS. CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN
ALL SAFETY DEVICES, INCLUDING SHORING AND BRACING, AND SHALL BE SOLELY
RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND
HEALTH STANDARDS, LAWS AND REGULATIONS.
6.SAFETY: CONFORM TO ALL APPLICABLE OSHA CONSTRUCTION SAFETY REGULATIONS
FOR ALL WORK PERFORMED DURING CONSTRUCTION. JOB SITE SAFETY IS STRICTLY
THE RESPONSIBILITY OF THE CONTRACTOR AND NOT THE ENGINEER OR OWNER.
7.ANY PROPRIETARY COMPONENTS, MOUNTS, MATERIALS, CHEMICAL, EPDXY AND WEDGE
ANCHORS, AND SHOT PINS SHALL BE EXACTLY AS CALLED FOR IN THESE DRAWINGS.
ANY DEVIATIONS SHALL BE APPROVED OR DISAPPROVED BY THE ENGINEER AT THE
EXPENSE OF THE ENTITY REQUESTING THE SUBSTITUTION PRIOR TO THE
INSTALLATION.
8.THE CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE ALL ITEMS DEFINED IN THE
CONTRACT DOCUMENTS. THE CONTRACT DOCUMENTS INCLUDE, BUT ARE NOT LIMITED
TO, THE FOLLOWING: THE CONTRACT, SPECIFICATIONS AND CONSTRUCTION DRAWINGS.
9.THE CONTRACTOR SHALL BE ULTIMATELY RESPONSIBLE FOR COORDINATION AND
ASSEMBLY OF ALL PARTS OF THE CONSTRUCTION DEPICTED HEREIN. THE
CONTRACTOR SHALL PERFORM ANY CONSTRUCTABILITY REVIEW OR COORDINATION
DRAWINGS NECESSARY TO IDENTIFY CONSTRUCTABILITY PROBLEMS PRIOR TO
CONSTRUCTION.
10. THE CONTRACTOR SHALL VISIT THE JOB SITE TO REVIEW THE SCOPE OF WORK
AND EXISTING JOB SITE CONDITIONS INCLUDING, BUT NOT LIMITED TO, MECHANICAL,
ELECTRICAL SERVICE AND OVERALL COORDINATION. THE CONTRACTOR SHALL VERIFY
ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO SUBMITTING HIS BID. ANY
DISCREPANCIES, CONFLICTS OR OMISSIONS, ETC., SHALL BE REPORTED TO THE
CARRIER CONSTRUCTION SUPERVISOR BEFORE PROCEEDING WITH THE WORK.
11. THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR
DURING CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING STRUCTURES,
LANDSCAPING OR EQUIPMENT SHALL BE IMMEDIATELY REPAIRED OR REPLACED TO
THE SATISFACTION OF THE TENANT, BUILDING OWNER OR OWNER'S REPRESENTATIVE
AT THE EXPENSE OF THE CONTRACTOR.
12. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL
EXISTING UTILITIES, WHETHER SHOWN HEREON OR NOT, AND TO PROTECT THEM
FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES FOR REPAIR OR
REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED IN CONJUNCTION WITH
THE EXECUTION OF WORK.
13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF
THE SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED.
14. THE CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER AND TOILET
FACILITIES AS REQUIRED BY THE GOVERNING AGENCY.
15. THE CONTRACTOR AND ALL SUBORDINATE CONTRACTORS SHALL COMPLY WITH
ALL LOCAL AND STATE AND FEDERAL REGULATIONS.
16. THE CONTRACTOR SHALL OBTAIN AND PAY FOR PERMITS, LICENSES AND
INSPECTIONS NECESSARY FOR PERFORMANCE OF THE WORK AND INCLUDE THOSE IN
THE COST OF THE WORK TO CARRIER.
17. CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD. UNLESS SPECIFICALLY
NOTED, DO NOT FABRICATE ANY MATERIALS OFF SITE, NOR PERFORM ANY
CONSTRUCTION ACTIVITIES UNTIL THE ACCURACY OF DRAWING DIMENSIONS HAVE
BEEN VERIFIED AGAINST ACTUAL FIELD DIMENSIONS. IN ALL CASES WHERE A
CONFLICT MAY OCCUR, SUCH AS BETWEEN ITEMS COVERED IN SPECIFICATIONS AND
NOTES ON THE DRAWINGS OR BETWEEN GENERAL NOTES AND SPECIFIC PLANS OR
DETAILS, THE ENGINEER SHALL BE NOTIFIED, AND HE/SHE WILL INTERPRET THE
INTENT OF THE CONTRACT DOCUMENTS PRIOR TO THE INSTALLATION OF THAT
PORTION OF WORK.
18. THE CONTRACTOR SHALL NOTIFY THE CARRIER CONSTRUCTION SUPERVISOR OF
ANY CONFLICTS OR DISCREPANCIES IN THE CONTRACT DOCUMENTS OR FIELD
CONDITIONS PRIOR TO EXECUTING THE WORK IN QUESTION.
19. THE CONTRACTOR SHALL NOTIFY THE CARRIER CONSTRUCTION SUPERVISOR IF
DETAILS ARE CONSIDERED UNSOUND, UNSAFE, NOT WATERPROOF, OR NOT WITHIN
CUSTOMARY TRADE PRACTICE. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT
THERE IS NO OBJECTION TO THE DETAIL. DETAILS ARE INTENDED TO SHOW THE END
RESULT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB
CONDITIONS, AND SHALL BE INCLUDED AS PART OF THE WORK.
20. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY
THE CONTRACTOR BEFORE CONSTRUCTION. IF THEY DIFFER FROM THOSE SHOWN ON
THE PLANS, THE CONTRACTOR SHALL NOTIFY THE CARRIER CONSTRUCTION
SUPERVISOR SO THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE
WORK.
21. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED
CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR
EXACT MEANING, THE ENGINEER SHALL BE CONTACTED FOR CLARIFICATION BEFORE
PROCEEDING WITH THE WORK.
22. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING,
FRAMING, HANGERS OR OTHER SUPPORT NOT OTHERWISE SHOWN HEREIN. ALL
SUSPENDED MECHANICAL EQUIPMENT TO BE SWAY OR LATERALLY BRACED.
23. GOVERNING AGENCY -APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND
SHALL NOT BE USED BY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT SAME
INFORMATION. AT ALL TIMES THESE ARE TO BE UNDER THE CARE OF THE JOB
SUPERINTENDENT.
24. DESIGN DRAWINGS ARE DIAGRAMMATIC ONLY AND SHALL BE FOLLOWED AS
CLOSELY AS ACTUAL CONSTRUCTION CONDITIONS WILL PERMIT. ANY ERROR,
OMISSION, OR DESIGN DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE
CARRIER CONSTRUCTION SUPERVISOR FOR CLARIFICATION OR CORRECTION BEFORE
CONSTRUCTION.
25. AS -BUILT REQUIREMENTS: DO NOT USE RECORD DOCUMENTS FOR
CONSTRUCTION PURPOSES. PROTECT RECORD DOCUMENTS FROM DETERIORATION AND
LOSS IN A SECURE, FIRE-RESISTANT LOCATION. PROVIDE ACCESS TO RECORD
DOCUMENTS FOR THE CARRIERCONSTRUCTIONSUPERVISOR'S REFERENCE
DURING G
NORMAL WORKING HOURS. MAINTAIN A CLEAN, UNDAMAGED SET OF BLUE OR BLACK
LINE PRINTS OF CONTRACT DRAWINGS AND SHOP DRAWINGS. MARK THE SET TO
SHOW THE ACTUAL INSTALLATION WHERE THE INSTALLATION VARIES SUBSTANTIALLY
FROM THE WORK AS ORIGINALLY SHOWN. MARK WHICH DRAWINGS ARE MOST
CAPABLE OF SHOWING CONDITIONS FULLY AND ACCURATELY. WHERE SHOP DRAWINGS
ARE USED, RECORD A CROSS-REFERENCE AT THE CORRESPONDING LOCATION ON
THE CONTRACT DRAWINGS. GIVE ATTENTION TO CONCEALED ELEMENTS THAT WOULD
BE DIFFICULT TO MEASURE AND RECORD AT A LATER DATE. MARK RECORD SETS
WITH RED ERASABLE PENCIL. USE OTHER COLORS TO DISTINGUISH BETWEEN
VARIATIONS IN SEPARATE CATEGORIES OF THE WORK. MARK NEW INFORMATION THAT
IS IMPORTANT TO THE OWNER BUT WAS NOT SHOWN ON THE CONTRACT DRAWINGS,
DETAILS OR SHOP DRAWINGS. NOTE RELATED CHANGE ORDER NUMBERS WHERE
APPLICABLE. NOTE RELATED RECORD DRAWING INFORMATION AND PRODUCT DATA.
UPON COMPLETION OF THE WORK, SUBMIT ONE (1) COMPLETE SET OF RECORD
DOCUMENTS TO THE CARRIER CONSTRUCTION SUPERVISOR FOR THE OWNER'S
RECORDS.
26. A CLOSEOUT BOOK CONTAINING THE FOLLOWING, SHALL BE PROVIDED BY THE
CONTRACTOR, AS APPLICABLE:
A.AS BUILT DESIGN DRAWINGS
B.SWEEP TEST RESULTS
C.RESISTIVELY TEST
D.PHOTO DOCUMENTATION OF:
I. UNDERGROUND CONDUITS AND GROUND RING
II. ANTENNA, COAX, JUMPER ATTACHMENTS AND GROUND KIT ATTACHMENTS
III. ANTENNA DOWN TILT MEASUREMENT USING AN INCLINOMETER ON THE BACK
PLANE OF THE ANTENNA
IV. GROUND BAR ATTACHMENTS
E.SIGNED OFF PERMIT CARDS
F.CERTIFICATE OF OCCUPANCY
G.RETURN OF KEYS AND/OR ACCESS AUTHORIZATION
H.ORIGINAL BUILDING PERMIT
SITE WORK NOTES
1.SCOPE: CLEARING, GRUBBING, STRIPPING, EROSION CONTROL, SURVEY, LAYOUT, SUB
GRADE PREPARATION, FINISH GRADING AND SECURITY FENCE, AS REQUIRED BY
CONSTRUCTION DRAWINGS AND DETAIL DRAWINGS.
2.REFERENCES:
A.DEPARTMENT OF TRANSPORTATION CONSTRUCTION AND MATERIAL SPECIFICATIONS
FOR THE STATE IN WHICH THE PROJECT IS LOCATED.
B.ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS)
C.OSHA (OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION)
D.AASHTO (AMERICAN ASSOCIATION OF STATE TRANSPORTATION OFFICIALS)
3.INSPECTION AND TESTING:
A.FIELD TESTING OF EARTHWORK, AGGREGATE BASE COURSE, COMPATION AND
CONCRETE TESTING SHALL BE PERFORMED BY THE CONTRACTOR'S INDEPENDENT
TESTING LAB.
B.ALL WORK SHALL BE INSPECTED AND RELEASED BY THE CARRIER CONSTRUCTION
SUPERVISOR WHO SHALL CARRY OUT THE GENERAL INSPECTION OF THE WORK
WITH SPECIFIC CONCERN TO PROPER PERFORMANCE OF THE WORK AS
SPECIFIED AND/OR CALLED FOR ON THE DRAWINGS. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO REQUEST TIMELY INSPECTIONS PRIOR TO PROCEEDING WITH
FURTHER WORK THAT WOULD MAKE PARTS OF THE WORK INACCESSIBLE OR
DIFFICULT TO INSPECT.
4.SITE MAINTENANCE AND PROTECTION:
A.PROVIDE ALL NECESSARY JOB SITE MAINTENANCE FROM COMMENCEMENT OF THE
WORK UNTIL COMPLETION OF THE CONTRACT.
B.CONTACT THE ONE -CALL UTILITY LOCATION SERVICE PRIOR TO ANY EXCAVATING
ACTIVITIES TO HAVE LOCATIONS OF UNDERGROUND UTILITIES VERIFIED.
C.AVOID DAMAGE TO THE SITE INCLUDING EXISTING FACILITIES, STRUCTURES, TREES
AND SHRUBS DESIGNATED TO REMAIN. TAKE PROTECTIVE MEASURES TO PREVENT
EXISTING ITEMS THAT ARE NOT DESIGNATED FOR REMOVAL FROM BEING DAMAGED
BY THE WORK.
D.KEEP SITE FREE OF ALL PONDING WATER.
E.CONTRACTOR SHALL PROVIDE ALL EROSION AND SEDIMENTATION CONTROL
MEASURES AS REQUIRED BY LOCAL, CITY, COUNTY AND STATE CODES AND
ORDINANCES TO PROTECT EMBANKMENTS FROM SOIL LOSS AND TO PREVENT
ACCUMULATION OF SOIL AND SILT IN STREAMS AND DRAINAGE PATHS LEAVING
THE CONSTRUCTION AREA. THIS MAY INCLUDE SUCH MEASURES AS SILT FENCES,
STRAW BALE SEDIMENT BARRIERS AND CHECK DAMS.
F.PROVIDE AND MAINTAIN ALL TEMPORARY FENCING, BARRICADES, WARNING
SIGNALS AND SIMILAR DEVICES NECESSARY TO PROTECT LIFE AND PROPERTY
DURING THE ENTIRE PERIOD OF CONSTRUCTION. REMOVE ALL SUCH DEVICES
UPON COMPLETION OF THE WORK.
5.BEFORE STARTING GENERAL SITE PREPARATION ACTIVITIES, INSTALL EROSION AND
SEDIMENT CONTROL MEASURES. THE WORK AREA SHALL BE CONSTRUCTED AND
MAINTAINED IN SUCH CONDITION THAT IN THE EVENT OF RAIN THE SITE WILL BE
WELL DRAINED AT ALL TIMES.
6.ENSURE POSITIVE DRAINAGE DURING AND AFTER COMPLETION OF CONSTRUCTION.
7.PERFORM ALL SURVEY, LAYOUT, STAKING AND MARKING TO ESTABLISH AND MAINTAIN
ALL LINES, GRADES, ELEVATIONS AND BENCHMARKS NEEDED FOR EXECUTION OF THE
WORK.
8.CLEAR AND GRUB THE AREA WITHIN THE LIMITS OF THE SITE AND ONLY THE
IMMEDIATE SURROUNDINGS NECESSARY TO COMPLETE THE WORK. REMOVE TREES,
BRUSH, STUMPS, RUBBISH AND OTHER DEBRIS AND VEGETATION RESTING ON OR
PROTRUDING THROUGH THE SURFACE OF THE SITE AREA TO BE CLEARED AND
GRUBBED.
9.REMOVE FROM THE SITE AND DISPOSE IN AN AUTHORIZED LANDFILL ALL DEBRIS
RESULTING FROM CLEARING AND GRUBBING OPERATIONS. BURNING IS NOT
PERMITTED.
10. PRIOR TO EXCAVATING, THOROUGHLY EXAMINE THE AREA TO BE EXCAVATED
AND/OR TRENCHED TO VERIFY THE LOCATIONS OF FEATURES INDICATED ON THE
DRAWINGS, AND ASCERTAIN THE EXISTENCE AND LOCATION OF ANY STRUCTURE,
UNDERGROUND STRUCTURE, CULVERT, STREAM CROSSING OR OTHER ITEM NOT
SHOWN THAT MIGHT AFFECT OR INTERFERE WITH THE NEW CONSTRUCTION. NOTIFY
THE CARRIER CONSTRUCTION SUPERVISOR OF ANY OBSTRUCTIONS THAT WILL
PREVENT ACCOMPLISHMENT OF THE WORK AS INDICATED ON THE DRAWINGS.
11. SEPARATE AND STOCKPILE ALL EXCAVATED MATERIALS SUITABLE FOR BACK FILL.
ALL EXCESS EXCAVATED, AND UNSUITABLE MATERIALS SHALL BE DISPOSED OF IN AN
AREA DESIGNATED BY THE CARRIER CONSTRUCTION SUPERVISOR. (UNSUITABLE
MATERIAL MAY BE REQUIRED TO BE REMOVED FROM THE SITE.)
SECURITY FENCE NOTES
1.PROVIDE AND INSTALL THE GALVANIZED FENCE WITH ASSOCIATED POSTS, RAILS,
BRACES, FABRIC, TERMINAL POST, GATES, DROP BAR AND BARBED WIRE. USE
APPLICABLE PROVISIONS OF ASTM FOR MATERIALS.
2.FABRIC SHALL BE HEAVY GALVANIZED CHAIN LINK FENCE, CONFORMING TO ASTM
A392 2-INCH MESH 9 GAUGE WIRE (0.148 INCHES IN DIAMETER) WITH THE TOP
AND BOTTOM SELVAGES TWISTED AND BARBED.
3.POSTS:
A.LINE POST FOR FABRIC UP TO 8 FEET HIGH SHALL BE 2-3/8 INCH 0.D.
B.END CORNER, PUI I POST AND GATE POST SHALL BE 2-7/8 INCH 0.D. ALL
POSTS SHALL BE SCHEDULE 40 GALVANIZED STEEL PIPE IN ACCORDANCE WITH
ALL APPLICABLE ASTM STANDARDS FOR FENCES OVER 8 FEET HIGH, SIZE POST
ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
4.TOP RAILS SHALL CONFORM TO 1-1/4 INCH (1.66-INCH 0.D.), SCHEDULE 40
GALVANIZED STEEL PIPE IN ACCORDANCE WITH ASTM4 Al2D.
5.TENSION WIRE SHALL BE 7-GAUGE U.S. STEEL WIRE GALVANIZED IN ACCORDANCE
WITH ASTM A116, COATING CLASS III.
6.BRACE BANDS, TENSION BANDS AND TENSION BARS SHALL BE FABRICATED OF 1/8
INCH BY 7/8 INCH GALVANIZED STEEL WITH GALVANIZED STEEL CARRIAGE BOLTS
AND NUTS IN ACCORDANCE WITH ASTM4 A123. TENSION BARS SHALL BE 1/4 INCH
BY 3/4 INCH GALVANIZED STEEL BAR IN ACCORDANCE WITH ASTM A153.
7.FABRIC TIES SHALL BE CLASS I GALVANIZED STEEL WIRE NO LESS THAN 9-GAUGE.
8.POST TOPS SHALL BE PRESSED STEEL OR MALLEABLE IRON AND SHALL BE
GAI VANIZED PER ASTM A15J.
9.BARBED WIRE SHALL CONSIST OF DOUBLE STRANDED 12-1/2 GAUGE WIRE ASTM
A121, CLASS 3 WITH 4-POINT BARBS SPACED 5 INCHES APART. THE TOP 1 FOOT
OF THE FENCE SHALL CONSIST OF 3 STRANDS OF BARBED WIRE ATTACHED TO
45-DEGREE ANGLE, HEAVY -PRESSED ARMS CAPABLE OF WITHSTANDING WITHOUT
FAILURE 250 POUNDS DOWNWARD PULL AT THE OUTERMOST END OF THE ARM.
10. GATE MATERIALS, SUCH AS FABRIC, BOLTS, NUTS, TENSION BARS AND BARBED
WIRE SHALL BE CONSISTENT WITH FENCE MATERIALS.
11. THE BOTTOM OF THE FENCE SHALL BE 2 INCHES BELOW THE TOP OF THE
COMPOUND GRAVEL IF THE SITE CROSSES FEATURES SUCH AS DRAINAGE DITCHES,
ETC., THE FENCE SHALL SPAN THE DEPRESSION. CLOSE THE SPACE BELOW THE
BOTTOM OF THE FENCE WITH EXTRA FENCE FABRIC OR BARBED WIRE AS DIRECTED
BY THE CARRIER CONSTRUCTION SUPERVISOR. PRIOR TO PLACING COMPONENTS
SUCH AS FABRIC, RAILS, TENSION WIRE AND GATES, ENSURE THAT THE CONCRETE
POST FOUNDATION HAS REACHED AT LEAST 75% OF ITS DESIGN STRENGTH OR HAS
CURED A MINIMUM OF 7 DAYS AFTER SETTING THE POST.
12. FURNISH GATES WITH NECESSARY FITTINGS AND HARDWARE. HINGES SHALL
ALLOW SWING GATES TO SWING 180 DEGREES. PLUNGER BARS SHALL HAVE TOP,
BOTTOM AND MIDDLE LOCKING POINTS WITH THE MIDDLE POINT ARRANGED FOR
PADLOCKING. GATES SHALL HAVE KEEPERS ON EACH LEAF T„Sil�`-,
AUTOMATICALLY WHEN THE GATE IS SWUNG OPEN. REPAIR -V 12-rt QE3A�Ty ®
DAMAGED IN THE FIELD WITH METHODS AND TECHNIQUES A ffE OTA�
MANUFACTURER.
AUG 2 7 2010
Community
Development
T
• •Mobile•
A
AMERICAN TOWER°
/04:464Sk
POWDER RIVER
Engineering Services, LLC
www.powdeniverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
OATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
8
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
8813 REGISTERED
\1\\I ARCHITECT
GLENN WALKER
STATE OF WASHINGTON
OB/17/18
THESE RAMS AND SPECIFCATIOMS. AS INSTRUMENTS OF SERNCE, ARE
AND SMALL REAM TIE PROPERTI OF POWDER RIVER DEVELOPMENT
WARMS. LLC WHETHER TIE PROJECTS FOR wntn THEY ARE WADE
ARE COCOTTE/ OR NOT. THESE DRAWLS AND SPECNIEATIONs SMALL
NOT H USED BY ANY PERSON OR 001115 ON OTNER PROJECTS
WTMOUT PRIOR MINDEN CONSENT OF TIE OCINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
GENERAL
NOTES
SHEET NUMBER:
GN-1
ELECTRICAL NOTES
1. THESE NOTES DESCRIBE THE MINIMUM REQUIREMENT FOR INSTALLATION OF ALL
ELECTRICAL SYSTEMS. SUBMITTAL OF BID INDICATES THAT THE CONTRACTOR IS
COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PERFORMED UNDER
THIS CONTRACT.
2.THE PUBLICATIONS LISTED BELOW FORM PART OF THESE NOTES. EACH PUBLICATION
SHALL BE THE LATEST REVISION AND ADDENDUM IN EFFECT ON THE DATE THIS
SPECIFICATION IS ISSUED FOR CONSTRUCTION, UNLESS NOTED OTHERWISE. EXCEPT
AS MODIFIED BY THE REQUIREMENTS SPECIFIED HEREIN, OR THE DETAILS OF THE
DRAWINGS, WORK INCLUDED IN THIS SPECIFICATION SHALL CONFORM TO THE
APPLICABLE PROVISIONS OF THESE PUBLICATIONS:
A. ANSI (AMERICAN NATIONAL STANDARDS INSTITUTE)
B. IEEE (INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS)
C. NEC (NATIONAL ELECTRICAL CODE), LATEST EDITION
D. NEMA (NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION)
E. NFPA 70 (NATIONAL FIRE PROTECTION ASSOCIATION)
F. OSHA (OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION), INCLUDING ALL
APPLICABLE AMENDMENTS
G. UL (UNDERWRITERS LABORATORIES)
H. APPLICABLE LOCAL CODES AND ORDINANCES
3.THE CONTRACTOR SHALL INSTALL UNDERGROUND ELECTRICAL AND TELEPHONE
CONDUITS AND CABLE AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS.
4.WHEN FINISHED, WORK SHALL BE IN A COMPLETE AND UNDAMAGED STATE, AS
REQUIRED IN THE CONTRACT DOCUMENTS.
5.ITEMS SHALL BE NEW AND SHALL BE INSTALLED ONLY IF IN FIRST-CLASS
CONDITION.
6.SUBSTITUTIONS FOR MATERIAL WILL BE PERMITTED ONLY BY WRITTEN APPROVAL OF
THE CARRIER CONSTRUCTION SUPERVISOR AND BY THE ENGINEER.
7.THE CONTRACTOR SHALL PROVIDE ALL MATERIAL EXCEPT AS SPECIFIED IN THE
CONTRACT DOCUMENTS. ALL MATERIAL SHALL BE APPROVED AND LISTED BY OR
BEAR THE UL LABEL, AND WILL COMPLY WITH ANSI, IEEE AND NEMA STANDARDS
WHERE APPLICABLE.
8.CONDUITS:
A. ALL UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC , SIZED AS SHOWN
ON THE CONSTRUCTION DRAWINGS.
B. ALL EXTERIOR ABOVEGROUND CONDUIT SHALL BE PER LOCAL CODE
REQUIREMENTS.
C. ALL INTERIOR CONDUIT SHALL BE EMT WITH COMPRESSION -TYPE FITTINGS.
D. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FOR OUTDOOR
LOCATIONS WHERE FLEXIBLE CONNECTION IS REQUIRED.
9.CABLES CONDUCTORS FOR GENERAL WIRING SHALL BE NEC STANDARD ANNEALED
COPPER WIRE WITH NEC 600-VOLT INSULATION.
A. #8 AND LARGER -STRANDED TYPE, THHN OR THWN.
B. #10 AND SMALLER -SOLID TYPE THHN OR THWN.
C. CONDUCTORS IN CONDUIT IN OR ADJACENT TO HIGH HEAT SOURCE SHALL BE
TYPE XHHW.
D. CONDUCTORS IN CONDUITS ABOVE ROOF, ON TOP OF ROOF OR INSIDE
BUILT-UP ROOFING MATERIAL SHALL BE TYPE XHHW
10. CONVENIENCE OUTLET, UNLESS NOTED OTHERWISE, SURFACE -MOUNTED OUTLETS
FOR EXTERIOR LOCATIONS SHALL BE FERALOY, CAD/ZINC ELECTROPLATED WITH
THREADED HUBS OR CONDUIT ENTRANCES DRILLED AND TAPPED. ALL COVERS SHALL
BE SELF -CLOSING AND GASKETED. SURFACE MOUNTED OUTLETS FOR INTERIOR
LOCATIONS SHALL BE GALVANIZED, PRESSED STEEL WITH COVER PLATE, SIERRA
PLASTIC STYLE, IVORY COLOR.
11. COAXIAL CABLE SUPPORTS 1. ALL WAVE GUIDE SUPPORTS SHALL BE
MANUFACTURED TO MEET ALL COAX MINIMUM BENDING REQUIREMENTS. SUPPORTS
SHALL BE PROVIDED EVERY 3'-0" ON CENTER.
12. BEFORE LAYING OUT WORK, EXERCISE PROPER PRECAUTION TO VERIFY EACH
MEASUREMENT.
13. USE EXTREME CAUTION BEFORE EXCAVATING IN EXISTING AREAS TO LOCATE
EXISTING UNDERGROUND SERVICES.
14. A VISUAL CHECK OF ELECTRICAL AND TELEPHONE CABLES, CONDUITS AND
OTHER ITEMS SHALL BE MADE BY A CARRIER CONSTRUCTION SUPERVISOR BEFORE
THESE ITEMS ARE PERMANENTLY INSTALLED.
15. THE CONTRACTOR SHALL NOTIFY THE CARRIER CONSTRUCTION SUPERVISOR 24
HOURS PRIOR TO TRENCH BACK FILL.
16. TRENCHING, BACK FILLING, BEDDING AND COMPACTING SHALL COMPLY WITH SITE
WORK SPECIFICATIONS.
17. DIG TRENCHES TO THE REQUIRED DEPTH AS SHOWN ON THE DRAWINGS
WITHOUT POCKETS OR DIPS. REMOVE LARGE STONES FROM THE BOTTOM OF THE
TRENCH AND FIRMLY TAMP LOOSE FILL IN THE BOTTOM BEFORE CONDUIT IS LAID.
18. INSTALL UNDERGROUND CONDUIT WITH A MINIMUM 3-INCH TO 100-FOOT SLOPE
OR TO A SLOPE SHOWN ON THE DRAWINGS.
19. UNLESS SHOWN OTHERWISE ON THE DRAWINGS, TERMINATE AND CAP ALL
STUB -UPS 12 INCHES ABOVE FINISHED GRADE ELEVATION.
20. WHEREVER CONDUITS CROSS UNDER ROADWAYS, USE GALVANIZED RIGID STEEL
CONDUITS IN ALL CASES, EXTENDING 5 FEET BEYOND THE EDGE OF THE ROAD BED.
MINIMUM DEPTH FOR CONDUIT SHALL BE 4 FEET BELOW ROADWAY GRADE.
21. MARK UNDERGROUND CONDUITS WITH A 6-INCH WIDE RED POLYETHYLENE TAPE
BURIED 6 INCHES UNDER THE SURFACE DIRECTLY OVER THE CONDUITS. MARK THE
TAPE THUS: CAUTION -BURIED ELECTRICAL CABLE.
22. FOR SEALING CONDUITS, USE ONLY NON -THERMOPLASTIC COMPOUNDS SUCH AS
J.M. DUXSEAL, OR AN CARRIER -APPROVED SUBSTITUTE. THE COMPOUND SHALL HAVE
NO EFFECT ON RUBBER OR RUBBER -LIKE INSULATIONS, LEAD, ALUMINUM OR
FERROUS ALLOYS; IT SHALL BE INSOLUBLE IN WATER AND WITHSTAND MAXIMUM
TEMPERATURE RANGES OF THE LOCALITY.
23. COAXIAL - REFER TO ANTENNA AND COAXIAL CABLE INSULATION PROCEDURES.
24. ANTENNA - REFER TO ANTENNA AND COAXIAL CABLE INSULATION PROCEDURES.
25. LNA/MHA - REFER TO ANTENNA AND COAXIAL CABLE INSULATION PROCEDURES.
GROUNDING NOTES
1. THIS SPECIFICATION PRESCRIBES THE REQUIREMENTS FOR FURNISHING, INSTALLATION
AND TESTING OF THE GROUNDING CABLE, CONNECTORS AND ASSOCIATED
COMPONENTS AS INDICATED ON THE DRAWINGS.
2.APPLICATIONS OF ELECTRICAL GROUNDING AND BONDING WORK SPECIFIED IN THIS
SPECIFICATION INCLUDE THE FOLLOWING:
A. FENCE AND GATE POSTS
B. ELECTRICAL POWER SYSTEMS
C. GROUNDING ELECTRODES
D. GROUND BUS BAR
E. SERVICE EQUIPMENT
F. ENCLOSURES
G. MONOPOLE / LATTICE TOWER
H. ICE BRIDGE
3.REFERENCES: THE PUBLICATIONS LISTED BELOW FORM PART OF THESE DRAWINGS.
EACH PUBLICATION SHALL BE THE LATEST REVISION AND ADDENDUM IN EFFECT ON
THE DATE THESE DRAWINGS ARE ISSUED FOR CONSTRUCTION, UNLESS NOTED
OTHERWISE. EXCEPT AS MODIFIED BY THE REQUIREMENTS SPECIFIED HEREIN, OR
THE DETAILS OF THE DRAWINGS, WORK INCLUDED IN THESE DRAWINGS SHALL
CONFORM TO THE APPLICABLE PROVISIONS OF THESE PUBLICATIONS.
A. ANSI (AMERICAN NATIONAL STANDARDS INSTITUTE)
B. IEEE (INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS)
C. NEC (NATIONAL ELECTRICAL CODE), LATEST EDITION
D. NEMA (NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION)
E. NESC (NATIONAL ELECTRICAL SAFETY CODE), LATEST EDITION
F. OSHA (OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION)
G. UL (UNDERWRITERS' LABORATORIES)
H. APPLICABLE LOCAL CODES AND ORDINANCES
4.MATERIALS: EXCEPT AS OTHERWISE INDICATED, PROVIDE ELECTRICAL GROUNDING AND
BONDING SYSTEMS INDICATED; WITH ASSEMBLY OF MATERIAL, INCLUDING, BUT NOT
LIMITED TO, GROUNDING ELECTRODES, BONDING JUMPER AND ADDITIONAL
ACCESSORIES NEEDED FOR A COMPLETE INSTALLATION. WHERE MORE THAN ONE
TYPE OF COMPONENT PRODUCT MEETS INDICATED REQUIREMENTS, SELECTION IS
INSTALLER'S OPTION. WHERE MATERIALS OR COMPONENTS ARE NOT INDICATED,
PROVIDE PRODUCTS WHICH COMPLY WITH NEC, UL, AND IEEE REQUIREMENTS AND
WITH ESTABLISHED INDUSTRY STANDARDS FOR THOSE APPLICATIONS INDICATED.
A. GROUNDING:
I. THE EQUIPMENT SHALL BE GROUNDED AS FOLLOWS, AS SHOWN ON THE
DRAWINGS AND IN COMPLIANCE WITH NEC ARTICLE 250 AND STATE AND
LOCAL CODES.
II. GROUND RODS AND QUANTITY SHOWN ON THE DRAWINGS ARE DIAGRAMMATIC.
THE CONTRACTOR SHALL PERFORM A GROUND -RESISTANCE -TO -EARTH
TEST. SHOULD THE INSTALLATION HAVE A RESISTANCE OF 5 OHMS OR
MORE, CONTRACTOR SHALL INSTALL MORE GROUND RODS AS NECESSARY
SO THAT THE OVERALL GROUND-TO-EARTHRESISTANCE IS LESS THAN 5
OHMS.
in. INSTALL ELECTRICAL GROUNDING AND BONDING SYSTEMS AS INDICATED, IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, NEC'S "STANDARD OF
INSTALLATION," AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY
PRACTICES TO ENSURE THAT PRODUCTS COMPLY WITH REQUIREMENTS.
IV. COORDINATE WITH OTHER ELECTRICAL WORK AS NECESSARY TO INTERFACE
INSTALLATION OF ELECTRICAL GROUNDING AND BONDING SYSTEMS.
V. INSTALL GROUND CONDUCTORS A MINIMUM OF 36 INCHES BELOW FINISHED
GRADE WHICH ENCIRCLE THE TOWER AND EQUIPMENT, AND ARE
CONNECTED TO EACH DRIVEN GROUND ROD. GROUND TRENCH SHALL BE
AT LEAST 24 INCHES AWAY FROM FOUNDATIONS.
VI. TIGHTEN GROUNDING AND BONDING CONNECTORS, INCLUDING SCREWS AND
BOLTS, IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED TORQUE
TIGHTENING VALUE FOR CONNECTORS AND BOLTS. WHERE MANUFACTURER'S
TORQUEING REQUIREMENTS ARE NOT INDICATED, TIGHTEN CONNECTIONS TO
COMPLY WITH TIGHTENING TORQUE VALUE SPECIFIED IN UL 486A TO
ASSURE PERMANENT AND EFFECTIVE GROUNDING.
VII. APPLY CORROSION -RESISTANT FINISH (NO-OX OR CARRIER -APPROVED
EQUIVALENT) TO FIELD -CONNECTIONS, AT COPPER GROUND BARS AND
PLACES WHERE FACTORY APPLIED PROTECTIVE COATING HAVE BEEN
DESTROYED, OR ARE SUBJECTED TO CORROSIVE AND/OR OXIDATION
PROCESS.
VIII. ON EXISTING LATTICE TOWERS, WATER TOWERS AND ROOF TOPS, WHEN A
NEW GROUNDING SYSTEM IS INSTALLED, THE CONTRACTOR SHALL TIE THE
NEW GROUND SYSTEM TO THE EXISTING WATER TOWER, LATTICE TOWER
STRUCTURAL STEEL OR BUILDING STRUCTURAL STEEL AS THE CASE MAY
BE AT A MINIMUM OF ONE LOCATION SO THAT THEY ARE AT THE SAME
VOLTAGE POTENTIAL.
IX. ALL TOWER AND TOP GROUND WIRES SHALL BE SUPPORTED EVERY TWO
FEET MAXIMUM.
B. GROUND RODS:
I. GROUND RODS SHALL BE 5/8" DIAMETER WITH 8'-0" EMBEDMENT MIN.,
COPPER CLAD DRIVEN ROD(S).
II. GROUND ROD(S) SHALL BE LOCATED AT THE PERIMETER OF EQUIPMENT AS
TO CREATE A GROUND RING AS SHOWN ON THE DRAWINGS.
III. GROUND ROD(S) SHALL BE SPACED AT A MINIMUM OF 8'-0" AND A
MAXIMUM SPACING OF 10'-0" ON CENTER.
IV. GROUND RODS SHALL BE BURIED BELOW THE FROSTLINE. AT NO TIME
SHALL THIS DEPTH BE LESS THAN 18" BELOW FINISHED GRADE.
V. GROUND RODS WHICH CANNOT BE DRIVEN STRAIGHT DOWN THE
ENTIRE 10'-0", SHALL BE DRIVEN AT AN ANGLE NOT GREATER
THAN 45 DEGREES (NEC 250-83 AND 250-84).
VI. GROUND ROD LOCATIONS SHALL BE NOTED ON THE AS -BUILT DRAWING
COMPLETE WITH DIMENSIONS.
VII. PROVIDE GROUND TEST WELLS SHOWN ON THE CONSTRUCTION DRAWINGS.
C.GROUND CONDUCTOR:
I. ALL DIRECT BURIED GROUND CONDUCTORS SHALL BE TINNED SOLID (#2
AWG) WIRE. BURIED GROUND CONDUCTOR SHALL BE INSTALLED AT
MINIMUM DEPTH OF 36" BELOW GRADE.
II. ALL SUB GRADE GROUND CONNECTIONS SHALL BE MADE USING EXOTHERMIC
WELD PROCESS. CONNECTIONS SHALL INCLUDE ALL CABLE TO CABLE
SPLICES, TEES AND ALL GROUND ROD CONNECTIONS. MOLD, WELD
KITS, ETC., SHALL BE MANUFACTURED BY CADWELD AND SHALL BE I
NSTALLED AS PER THE MANUFACTURER'S INSTRUCTIONS.
III. GROUND CONDUCTORS SHALL BE ROUTED IN THE SHORTEST AND C
STRAIGHTEST DISTANCES POSSIBLE TO MINIMIZE TRANSIENT VOLTAGE RISES.
CONDUCTORS SHALL BE INSTALLED AS FOLLOWS:
IV. ALL GROUND CONDUCTORS SHALL FOLLOW A CONTINUOUS DOWNWARD
PATTERN TO THE GROUND SOURCE. (NEVER RUN GROUND CONDUCTOR IN
AN UPWARD DIRECTION.)
V. CONDUCTORS SHALL BE INSTALLED WITH A MINIMUM OF 12-INCH MINIMUM
BENDING RADIUS.
VI. WHEN THE MINIMUM BENDING RADIUS CANNOT BE ACHIEVED, GROUND
CABLES SHALL BE ROUTED AT 90-DEGREE BENDS WITH THE USE OF
EXOTHERMIC CONNECTIONS AT 90 DEGREES, WITH THE INTENT IS TO
ELIMINATE THE CABLE BEND RADIUS AND REPLACE THE RADIUS WITH AN
EXOTHERMIC CONNECTION.
5.PREPARATION:
A. ALL SURFACES TO WHICH GROUND CONNECTIONS WILL BE MADE SHALL BE
FREE OF PAINT, GALVANIZING DIRECT CORROSION, ETC.
B. ALL METAL SURFACES EXPOSED ON GROUNDING SHALL BE EITHER COLD
GALVANIZE, OR PAINTED TO MATCH ORIGINAL SURFACE.
6.EXAMINE AREAS AND CONDITIONS UNDER WHICH ELECTRICAL GROUNDING AND
BONDING CONNECTIONS ARE TO BE MADE AND NOTIFY CARRIER CONSTRUCTION
SUPERVISOR AND ENGINEER OF RECORD IN WRITING OF CONDITIONS DETRIMENTAL
TO PROPER COMPLETION OF WORK. DO NOT PROCEED WITH WORK UNTIL
UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. THE CONTRACTOR SHALL
NOTIFY THE CARRIER CONSTRUCTION SUPERVISOR A MINIMUM OF 24 HOURS PRIOR
TO TRENCH BACK FILL. ALL WORK DONE BELOW FINISHED GRADE SHALL BE
INSPECTED BY THE CONSTRUCTION SUPERVISOR DURING THAT PERIOD.
7.GROUND TESTING:
A. THE CONTRACTOR SHALL TEST THE GROUND ELECTRODE ROD RESISTANCE IN
ACCORDANCE WITH THE METHODS OF MEASUREMENT DEFINED IN THE FALL OF
POTENTIAL METHOD.
B.TEST INSTRUMENTS SHALL OPERATE AT A FREQUENCY OTHER THAN 60 HERTZ
AND SHALL CONTAIN STRAY CURRENT AND DC FILTERS, FAULT CURRENT
PROTECTION AND HAVE SENSITIVITY TO OPERATE A LOW SIGNAL STRENGTH.
C. PRIOR TO TESTING, THE CONTRACTOR SHALL DE -ENERGIZE ALL POWER
SOURCES, DISCONNECT THE ELECTRODE CONDUCTOR FROM THE GROUND ROD,
WEAR HIGH VOLTAGE RUBBER SAFETY GLOVES.
D. GROUND TESTS ARE TO BE PERFORMED BY QUALIFIED PERSONS FAMILIAR WITH
THE CONSTRUCTION AND OPERATION OF THE EQUIPMENT AND THE HAZARDS
INVOLVED.
E. AN INDEPENDENT, APPROVED OUTSIDE FIRM SHALL PERFORM THE GROUND TEST
AS OUTLINED. ALL TEST RESULTS SHALL BE FORWARDED TO THE CARRIER
CONSTRUCTION SUPERVISOR FOR APPROVAL.
RECEIVED
AUG 27 2018
Commurfty
Development
T
• •Mobile
•
A
AMERICAN TOWER'
410t4bPk
POWDER RIVER
Engineering Services, LLC
www.powdeniverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
GATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
8
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
8813 REGISTERED
ARCHITECT
GLENN WALKER
STATE OF WASHINGTON
08/17/18
THESE PLANS AM SPECIFICATIONS. AS INSTRUMENTS OF SERVICE. ARE
Alm SNAIL RERAN ME PROPERTY OF PONDER RIVER DEVELOPMENT
SERVICES. U.0 WITHER ME PROJECTS !di WO. THEY ARE MADE
ARE EXECUTED OR MDT. THESE OPAWINCS AND S000*1CATIONS SMALL
MOT BE USED BY AM PERSON OR CHITTY ON OTTER PROJECTS
WITHOUT PRIOR WRR' IEM CONSENT OF THE EMIMEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
GENERAL
NOTES
SHEET NUMBER:
GN-2
ONRAMP TO
NORTHBOUND 1-5
EXISTING ACCESS ROAD
X
X
X
EXISTING
VEGETATION
X
EXISTING T-MOBILE
PPC/TELCO CABINET ON
CONCRETE PAD
EXISTING T-MOBILE
CONCRETE EQUIPMENT
PLATFORM
EXISTING T-MOBILE
PURCELL CABINET
EXISTING T-MOBILE
ULTRASITE CABINET
TO BE REMOVED
PROPOSED T-MOBILE
(1) AMOB, (1) ABIL,
(1) ASIK
EXISTING T-MOBILE
FCOA CABINET
EXISTING T-MOBILE
FSMF (2) AND FBBC (3)
E REMOVED
X
X
EXISTING
TRANSFORMER
EXISTING HANDHOLE
EXISTING T-MOBILE
ICE BRIDGE
PROPOSED T-MOBILE
(1) AMOB,(3) ABUT
(1) ASIA
X
EXISTING FENCE --\
X X
EXISTING
VAULT
EXISTING ICE
BRIDGE (OTHERS)
EXISTING T-MOBILE
H-FRAME
— EXISTING T-MOBILE
TO REMAIN (1 TOTAL)
EXISTING
MONOPOLE
EXISTING UTILITY
H-FRAME (OTHERS)
PROPOSED T-MOBILE
FCOA CABINET
EXISTING
EQUIPMENT
PLATFORM
(OTHERS)
DISCLAIMER:
THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A
CURRENT LAND SURVEY. ALL PROPERTY LINES, EASEMENTS,
SETBACKS, AND DIMENSIONS SHOWN SHALL BE VERIFIED PRIOR TO
START OF CONSTRUCTION. POWDER RIVER DEVELOPMENT SERVICES,
LLC. DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY
LINES, EASEMENTS, SETBACKS, AND DIMENSIONS SHOWN.
EXISTING CONCRETE WALL
EXISTING
VEGETATION
AUG 27 2018
ORILLIA ROAD
SITE PLAN
Community
Development
SCALE: 1/8" = 1'-0" (11x17)
1
T.
• •Mobile•
A
AMERICAN TOWER'
4004‘4SSiA
POWDER RIVER
Engineering Services, LLC
www.powdeniverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
B
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
8813 REGISTERED
\\I ARCHITECT
GLENN WALKER
STATE OF WASHINGTON
08/17/18
PIM PANS MID SEC AS DGTRIJYENTS OF SOMCE. ARE
MO SHALL MINN TIE VROPER, OF POWER RIVER DEVELOPMENT
SERVICES. LLC WHETHER DIE PROJECTS FOR MICN NEr ME MADE
ARE EXECUTED OR NOT. THESE °RAMNOS MO SPEGFIOATMM6 SMALL
POT BE USED BY ANY PERSON OR MCP, ON OTMER PROJECTS
WTNWT PRIM WRITTEN CONSEM OF TMC ENGINEER
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
SITE PLAN
SHEET NUMBER:
C-1
EXISTING T—MOBILE APPURTENANCE LIST:
(3)
(2)
(2)
(4)
(2)
(4)
(2)
(8)
(1)
(8)
(1)
SECTOR FRAMES
QUAD PORT ANTENNAS
HEX PORT ANTENNAS
TMA
FRLB
FHFB
FRIG
DIPLEXERS
COVP
COAX CABLES
HYBRID CABLE
T.O. LIGHTING ROD TIP
• EL. 64.2' (AGL)
• T.O. EXISTING ANTENNAS (OTHERS)
• EL. 61.2' (AGL)
OF EXISTING ANTENNAS (OTHERS)
• EL. 58.-0" (AGL)
O• E OF EXISTING EMPTY MOUNT (OTHERS)
• EL. 48.-0" (AGL)
4
Y
T.O. EXISTING T—MOBILE ANTENNAS
EL. 41'-0.5" (AGL)
EXISTING T—MOBILE ANTENNAS
EL. 38'-0" (AGL)
EXISTING T—MOBILE TMA
TO REMAIN
(2 PER SECTOR, 4 TOTAL)
EXISTING T—MOBILE FRLB
TO BE REMOVED
(1 PER SECTOR, 2 TOTAL)
EXISTING T—MOBILE COVP
TO REMAIN
(1 TOTAL)
EXISTING T—MOBILE
7/8" COAX CABLES
TO REMAIN
(8 TOTAL)
EXISTING -
MONOPOLE
EXISTING T—MOBILE
COVERED CONCRETE
EQUIPMENT PAD
GRADE
4. EL. 0'-0" (AGL)
T.O. EXISTING MONOPOLE h
EL. 60.5' (AGL)
EXISTING MICROWAVE (OTHERS)
EL. 51'-0" (AGL)
EXISTING T—MOBILE FHFB
TO BE REMOVED
(2 TOTAL)
EXISTING T—MOBILE FRIG
TO BE REMOVED
(1 PER SECTOR, 2 TOTAL)
EXISTING T—MOBILE ANTENNAS
TO BE REMOVED
(2 PER SECTOR, 4 TOTAL)
EXISTING T—MOBILE DIPLEXER
TO BE REMOVED
(4 PER SECTOR, 8 TOTAL)
EXISTING T—MOBILE
1-1/4" HYBRID CABLE
TO REMAIN
(1 TOTAL)
EXISTING
EQUIPMENT
PLATFORM
(OTHERS)
FINAL T—MOBILE APPURTENANCE LIST:
(1) LOW PROFILE ANTENNA PLATFORM
(2) MASSIVE MIMO ANTENNAS
(2) OCTA PORT ANTENNAS
(4) TMA
(2) AHLOA
(1) COVP
(8) COAX CABLES
(1) HYBRID CABLE
Aba T.O. LIGHTING ROD TIP
EL. 64.2' (AGL)
h T.O. EXISTING ANTENNAS (OTHERS)
Y EL. 61.2' (AGL)
osorE OF EXISTING ANTENNAS (OTHERS)
EL. 58.-0" (AGL)
4
4
OF EXISTING EMPTY MOUNT (OTHERS)
EL. 48.-0" (AGL)
EXISTING T—MOBILE TMA
(2 PER SECTOR, 4 TOTAL)
T.O. PROPOSED T—MOBILE ANTENNAS
EL 42'-0" (AGL)
PROPOSED T—MOBILE ANTENNAS
EL 38'-0" (AGL)
PROPOSED T—MOBILE
COMMSCOPE FFHH-65C—R3 ANTENNA
(1 PER SECTOR, 2 TOTAL)
PROPOSED T—MOBILE
AHLOA MOUNTED BEHIND ANTENNA
(1 PER SECTOR, 2 TOTAL)
EXISTING T—MOBILE COVP
(1 TOTAL)
EXISTING T—MOBILE
7/8" COAX CABLES
(8 TOTAL)
EXISTING
MONOPOLE
EXISTING T—MOBILE
COVERED CONCRETE
EQUIPMENT PAD
4
GRADE
EL. 0'-0" (AGL)
POWDER RIVER ENGINEERING SERVICES HAS
NOT PERFORMED STRUCTURAL ANALYSES FOR
THE NEW EQUIPMENT MOUNTS, NOR THE
SUPPORTING STRUCTURE, AND ASSUMES NO
RESPONSIBILITY FOR ITS ABILITY TO SUPPORT
THE PROPOSED MODIFICATIONS. PRIOR TO
CONSTRUCTION, STRUCTURAL ANALYSIS (BY
OTHERS) SHALL BE PERFORMED FOR ALL
TOWERS, ROOFTOPS, FLAGPOLES, LIGHT POLES
AND ASSOCIATED EQUIPMENT MOUNTS.
T.O. EXISTING MONOPOLE
EL. 60.5' (AGL)
EXISTING MICROWAVE (OTHERS)
EL. 51'-0" (AGL) V
PROPOSED T—MOBILE
NOKIA AAFIA NRSCALE MM
16T16R B25/B66 200W ANTENNA
(1 PER SECTOR, 2 TOTAL)
PROPOSED T—MOBILE
LOW PROFILE PLATFORM
(RMQP-4096—HK OR EQUIVALENT)
EXISTING T—MOBILE
1-1/4" HYBRID CABLE
(1 TOTAL)
EXISTING
EQUIPMENT
PLATFORM
(OTHERS)
RECEIVED
AUG 27 2018
Community
Development
TOWER ELEVATION (EXISTING)
SCALE 3/32" = 1-0" (11x17)
2
TOWER ELEVATION (PROPOSED)
SCALE. 3/32" = 1-0" (11x17)
1
T
• •Mobile
•
A
AMERICAN TOWER°
/044:SNk
POWDER RIVER
Engineering Services, LLC
www.powderriverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
8
08/09/18
ISSUED FOR REVIEW 903t
RJP
A
06/12/18
ISSUED FOR REVIEW 90X
RJP
8813 REGISTERED
\\\// ARCHITECT
GLENN WALKER
STATE OF WASHINGTON
08/17/18
THESE PO NS AHD SPE0FIUTONS. AS INSTRUMENTS OF SEANCE. ARE
AND SN*LL MINN DIE PROPERTY Of POWDER WEB DEVELOPMENT
SERVICES. LLC *METIER THE PROJECTS FOR WM101 THEY ARE MADE
ARE EXECUTED OR NOT. TEE DRAWINGS AND SPCONCATKINS SMALL
NOT BE USED 6F ANY PERSON OR ENTITY COI OTHER PROTECTS
WITHOUT PRIOR WI TIEN CONSENT Cf THE ENGINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
ELEVATIONS
SHEET NUMBER:
C-2
ANTENNA SCHEDULE
SECTOR
ALPHA (RED)
BETA
ANTENNA POSITION
A-1
A-2
B-1
,(BLUE)
B-2
ANTENNA TYPE
L700/U2100/G1900
L2100/L1900
L700/U2100/01900
L2100/L1900
AZIMUTH
0'
O'
220'
220'
RAD CENTER (AGL)
38-0
38-0
38'-0'
MODEL
COMMSCOPE
FFHH-65C—R3
NOKIA
AAF1A MASSIVE MIMO
COMMSCOPE
FFHH-65C—R3
NOKIA
MFIA MASSIVE MIMO
CABLE LENGTH
±70'-0"
POWDER RIVER ENGINEERING SERVICES HAS
NOT PERFORMED STRUCTURAL ANALYSES FOR
THE NEW EQUIPMENT MOUNTS, NOR THE
SUPPORTING STRUCTURE, AND ASSUMES NO
RESPONSIBILITY FOR ITS ABILITY TO SUPPORT
THE PROPOSED MODIFICATIONS. PRIOR TO
CONSTRUCTION, STRUCTURAL ANALYSIS (BY
OTHERS) SHALL BE PERFORMED FOR ALL
TOWERS, ROOFTOPS, FLAGPOLES, LIGHT POLES
AND ASSOCIATED EQUIPMENT MOUNTS.
ANTENNA SCHEDULE (PROPOSED)
1
EXISTING T—MOBILE ANTENNAS
TO BE REMOVED
(2 PER SECTOR, 4 TOTAL)
EXISTING T—MOBILE FRIGe
TO BE REMOVED
(1 PER SECTOR, 2 TOTAL)
EXISTING T—MOBILE DIPLEXERS
TO BE REMOVED
(4 PER SECTOR, 8 TOTAL)
EXISTING T—MOBILE FHFB
TO BE REMOVED
(2 TOTAL)
EXISTING T—MOBILE TMAs
TO REMAIN
(2 PER SECTOR, 4 TOTAL)
EXISTING T—MOBILE FRLB8
TO BE REMOVED
(1 PER SECTOR, 2 TOTAL)
EXISTING T—MOBILE COVP UNIT
TO REMAIN (1 TOTAL)
EXISTING T—MOBILE
T—ARMS
PROPOSED T—MOBILE
NOKIA AAFIA AJRSCALE MM
16T16R B25/B66 200W ANTENNA
(1 PER SECTOR, 2 TOTAL)
PROPOSED T—MOBILE AHLOA
(1 PER SECTOR, 2 TOTAL)
PROPOSED T—MOBILE
COMMSCOPE FFHH-65C—R3 ANTENNA
(1 PER SECTOR, 2 TOTAL)
EXISTING T—MOBILE TMAs
(2 PER SECTOR, 4 TOTAL)
EXISTING T—MOBILE COVP UNIT
(1 TOTAL)
PROPOSED T—MOBILE
LOW PROFILE PLATFORM
(RMQP-4096—HK OR EQUIVALENT)
RECEIVED N
AUG 27 2018
Community
Development
ANTENNA PLAN (EXISTING)
SCALE N T S
3
ANTENNA PLAN (PROPOSED)
SCALE: N.T.S
2
T
• •Mobile
•
A
AMERICAN TOWER'
Aligillik
POWDER RIVER
Engineering Services, LLC
www.powdeniverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
8
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
8813 REGISTERED
ARCHITECT
GLENN WALKER
STATE OF WASHINGTON
08/17/18
INESE PLANS AND SPECIFICATIONS. AS INSTRUMENTS OF SFRNCE, ARE
AA SNAIL REAM TK PROPERTY 0< POWDER RIVER DEVELOPMENT
APPALLS. LLC MNETIER 114E PROJECTS FOR MICN TREY ARE MACE
ARE EXECUTED OR NOT. MESS DRAWINGS AND SPECIFICATIONS SMALL
NOT EC USED BY ANY PERSON OR ENTT' ON OTHER PROJECTS
MT10UT PRICK WRITTEN C0115EM OF M ENGINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
ANTENNA PLANS
SHEET NUMBER:
C-3
6771 B_R4_2FRIA_Style1A1 BTMAUMTSGSMGRD.jpg
AHLOA
(600/700Mhz Dual Band)
Fa
r)I,IIII,,fy,01'1II fll(
11iI;, h I6YI1
Too
OVP
non. n
C DVP
- - Hair(
cam(
Prow d Fiber)
AlrMWM
LTE
A WS•PC S•700.600
A A
AWS
UMTS
6771B_R4
LTE AWS+PCS+600+700
UMTS AWS+GSM PCS
(Only Alpha Sects shown here(
u
T1
RIA
UMTS AWS
AAFIA
Tti
LTE AWS+PCS
(Alpha Sector)
-cam
lit AI ti1 It1 1.1
f01 t01 f0
o (pi c o o (4' o o �O
Mai
(try ItT? ITTt1.t1111111111lrlr lrrlirl
Gamow 1 Pea Apo.
SWF
UMTS AWS
1111111!.1
ESMB
GSM
Notes:
RECEIVED
AUG 27 2018
Community
Development
RF CONFIGURATION (PROVIDED BY T-MOBILE)
SCALE: N T S
T • •Mobile
•
A
AMERICAN TOWER'411014;
'NI
POWDER RIVER
Engineering Services, LLC
www.powderriverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
B
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
8413 REGISTERED
ARCHITECT
GLENN WALKER
STATE OF WASHINGTON
08 /17/18
THESE PUNS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE. ARE
AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT
SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE
ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL
NOT BE USED BY ANY PERSON OR ENTITY ON OTHER PROJECTS
WTRIOIJT PRIOR WRITTEN CoNsPNT OE THE ENGINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE
RFDS
SHEET NUMBER:
C-3.1
AirScale MAA 16T16R B25/B66 200W AAFIA
Dual band massive MIMO, 5G New Radio ready, integrated antenna system
AAFIA
AirScale MAA
825/66 200W -,
1
Radios
EDD LTE/LTE GATE-ho/5Bi
RR pow. per Mad
1DOW(16a 6.31V)
Bold Specrdtotlea
Ax TX
Read MI
1710-1760014t 2110-220014H7
Bead 25
1250- 1915 Milt 1930-1995 NHt
I,nS.Ewew
easdslllM
Mend 66: DL 9014112/UL 70M11s. Bw.d 25: DLM. 6514112
Ouupled Me66arINb
Mend 66: 4014112, Mead 25:401411
Power Coswmpdles
160044170% kadl. 2400W 100% load on both bands
Boltsl6Ndnj
N6rimnLlSet0rD48on, Azimuth BeamonnIng
ededdUdea &6rnas
0P55, 160AH. 6464 M. 25623414, 1024QAN
LI Split
LI Ls I RF
Ironthaal Mark.
CPRI 1Rato7L two 986b/s SEP ports par bard
1lourtbig
Walk Pak
IP Rating
665
lewd how
-46V DC6ange:-40d--5791
RA1640a650a300mm
24L9
CanWnWM
AirScale MAA 16T16R B25/B66 200W AAFIA
Antenna Details
Proms Ban �12
Sand 66
Sand 25
IX I TX
Rx 1 Tx
Antenna eanIspwatIon
&adunn Xy.. Mena
6-tabwm Ming rbma
Opwatirg 6eparr.cy
1710-17110
2110-2200
1650.1915
1930-1995
Baarnlounig EHA Ian 61 beard
123
724
>23
>24
AWN. boerwwa0951961beats
1613
1323
15 e9
1423
Bernrwmeq Gain BOBO 62 beam/
720
721
720
721
AMIAW,boarr+idl6. 62beam,
3434
3224
n!4
33t4
B..nrlwmYy Gain( 4ar g1.d
'16
116
118
>1e
/uinutMd ber,ue Elbarrd
Eks9I0n boanwdtN iypkd PI
6025
5.5 11
0025
5.5 31
6015
5.5 2 1
6005
5.511
INT1Ren1otg a0strisal WO
2,.12'
Beam staving rarye 1511
H- 45'
Barn stewing tango 1521
e/- 35'
USLS W10
> 15
SLS [r6tesimMN with power leperkp
' 20
P.onitoMes4 hfc,a1160'230' I661
> 25
Adw IMwnwdAlatir12a 4303rn RIM
a -153
NOKIA
NOKIA
v-
MANUFACTURER: COMMSCOPE
MODEL: FFHH-65C—R3
WEIGHT: 127.6 LBS
DIMENSIONS: HxWxD: 95.9" x 25.2" x 9.3"
FREQUENCY: 617MHz-806 MHz
1695-2360 MHz
CONNECTION: (8) 4.3-10 FEMALE
NOT USED
5
ANTENNA DETAILS
SCALE: N.T.S.
3
ANTENNA INFORMATION
SCALE N T S
1
TOP BRACKET
BOTTOM BRACKET
ANTENNA MOUNTING BRACKET
(OR EQUIV.), (TYP.)
PROPOSED ANTENNA
L Y'.:y was
AUG 27 201
Commur.ity
Deveioprnent
NOT USED
6
NOT USED
4
ANTENNA ATTACHMENT
SCALE: N.T.S
2
Ti
• •Mobile
•
A
AMERICAN TOWER'
POWDER RIVER
Engineering Services, LLC
www.powderriverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
B
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
88 ] ' REGISTERED
1\\I ARCHr,IT�E.CT�
GLENN WALKER
STATE, OF WASHINGTON
THESE PLANS AND SPECIFICATIONS. AS INSTRUMENTS OF SERVICE. ARE
AND SHALL REMAIN THE PROPERTY OF POWDER RHEA DEVELOPMENT
SERVICES. LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE
ARE EXECUTED DR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL
NOT BE USED BY ANY PERSON 0R Dom ON OTHER PROJECTS
WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
EQUIPMENT
DETAILS
SHEET NUMBER:
C-4
NOKIA
;w
ABlA Capacity
• User Plane
• RFM connectivity (6 RP3 Potts)
. UPto6units inDrtt subrack
• Housing for ABCA and ASIA plug -ins
• Ba_ plane inter.connesxiorts
between cards
One Subrack Indoor Maximum configuration :
• 6 ABIA +2 ASIA + 1 A M I A
•■ IP20 rating (Indoor)
One Subrack Outdoor Maximum configuration :
I
IM
.-
•
T„ •
;V
I
IYY,
,,.
t Ips
,
�m ,t
R I
"°
`"
C „, . .
I
- I-.1
'`
•
'
,
o
° °
rwwaww+wnna a.s�.t�,
I
+.am►. m•
....it p.... ";M1{,Ntii .._
6ABIA +2 ASIA +1 AMOB
!Nil!. y4mpp;� oarwy...���4p!,
. "".:Er; . nNg
IP65 rating
No boots on ASIA and ABIA fiber/power/Ethernet
-
Aldwa.walnaw
, _ in: i IMMex1. 51! lb lb
• V! ' I ' Is & . 11u101 %`M
CJ.. ...f♦��t « .. i • - _ _
connectors
Core Ma rM; 171•3ft
a IeixnaSat
B.ele.canllfse
FewrnreW art.23 Iso X,so «,.n
AHLOA: 600MHz/700MHz Radio (4Tx4Rx RRH)
-. -
NOTE: No power connections for Radio Module
ASIA Common !� Subrack
-,,,. . ow
rABIAandA:�tnplug-;.s
• Control Plane },. ,, .:°. _..
• Traraportcornecirvity
Half subrack Half subrack
units
�/'�/eY�%/�✓/ "Is« ' P t. . itM`r V• Av4,1!. 4d
ABIA '/�:'.. .. Ma
--•-- • =� -- == _� =�Cor
LMPower .TaADwl and
o,dPMc Power 4e30w
I5W/015W Fun andpoIT awl
PIM Cancellation yes'Matti Sandi.
Power Marini Yes
We11M 137 Ibswltl, no covers& brackets
Me
Dimensions 6L
d�el•lons 560 mm sMOt mm,ib9 non
CO nectOe 4 3.19.14 Ports)
AHLOA
• Tower Based installation only (No Ground installation)
• License requirement for MI MO Functions and Dual Band
• Utilizes 4.3-10 RF Connector
• CPRlfiberfronthaul
• Product expected Q2 2018
1 1 1 1.
�
Subrack
�_. ,•.
,�,. ,,. rA. ., e,l ai, ..I ..H,., tir, ,,
•
~�I:
A A ..• ,, A A
8 F. ,-.,' • Core a CanetDe AecSorn M M-Subrack M
I 1 .,.
i 7 »
ASIA • ■ y i• •
w: ,J� • • -
. SSSSSSS row' .• ' i �..•--:.:.a-•�.:_ —
-•
1 0 O-Sabred.
A B
''""
ASIA / ABIA / AMOB DETAIL
SCALE. NT S
3
RADIO INFORMATION
SCALE N T S
1
�`
ICI
•
�
14111111k
410li4
,`
Il•
►�010
__-
411
liPROPOSED
%41
\I
,
ANTENNA MOUNTING BRACKET,
SUPPLIED W/ ANTENNA (TYP)
/ PROPOSED T-MOBILE
ANTENNA
RADIO W/
MFG. SUPPLIED
MOUNTING HARDWARE
1 ;�. ./ iVE[
AUG 27 2018
Community
PROPOSED T-MOBILEDeVEIOpmQnt
ANTENNA MOUNTING PIPE
OR TOWER LEG
NOT USED
4
RADIO MOUNTING DETAIL
2
T ■ ■Mobile
■
A
AMERICAN TOWER'
POWDER RIVER
Engineering Services, LLC
www.powderriverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
B
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
881' REGISTERED
\\I ARCHITECT
GLENN WALKER
STATE OF WASHINGTON
IJ; s. li Its
THESE PLANS AND SPECIFICATIONS. AS INSTRUMENTS OF SERVICE, ARE
AND SHALL REMAIN THE PROPERTY OF POWDER RNER DEVELOPMENT
SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE
ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SNAIL
NOT BE USED BY ANY PERSON 0R ENTITY ON OTHER PROJECTS
WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
EQUIPMENT
DETAI LS
SHEET NUMBER:
C-5
• •
A IRE)'4CEO saw. E.wCP
REV OEWIIl*M OF MM..
REw01O01MT011T
!I1n I' 11A
PART LMT
11
11
11
1E
11
IE
11
a
11
1a
N
027
a
so
10
10
it
r
M•
an
052
11
at
1a
M
11
PART MO.
laaa
MEW
AMaUT
.M3N
21701aBE
01T1W
0111.
mos
I1LB1i00
BORE
ar E
GAMUT
0100M
PART OEaCMP110M
RIMO Maw T
M•M00L0OIWAMMR
M•M00 YnMOtMUT
M•. 17•1101E51.0 400R100T
Oars M• TILE AOEO R00!Mal
M•.aiM' MOO Ain 111111 BOLT
02,1400 530E 14TW.111EB
W 0 MT •ra r u/0.TIMO0J
t1Y IM WE RATS 211.1
021.1411L00MAMBlI
142•M00 Mow moat NM
alr OD a Or EM EO 000*04 hp*
lrir Or or MBaTRIOD.a
,Tr ■ Mr MOT M OLLVARBEO PIE
LOW RIDE[ MTTORM CORNER
aar 001 rr10N.o 650V.w200 P11E
CR0IE0VER RATE
1ri BvrXaln•S 2•MADLY (M00.1
W MOD HEAVY al M4 NTT
P41FBR11ram 0110EMLNT 071.000E
TaRAOMET FOR ROWORERMENT TUT
W. r MO OM BaT0a
1Ir.01r 400 N. BOLT Oa ROLL TMRL10
AMWE IIAIIBRAI CORIIBI SEMI
LEMOTM
0MM
1MY
IMM
iN
1Tar
UMIT
ao
O 20
u
O a
1a
Elf
1.n
1a
011
all
RCM
271
MLM
as
Aa
e at
1a
1.0
125E
427
OAT
n.M
Tm.L1W.•
TOLERANCE NOTES
1011YMataMM Yl1 10. 074a0t1111.M. tam AIM
rB0 .Hie a0M.M7m�a.AREr am,
•t
om atm.
1A�101R IMH.M 202E a mt. • Re some ammo
BMM1ARE210BBaa
ALL011MR 11150.1.41. 0 4107
r00T.111LB111111r Mom
ti
lammonao
II !I
,lil�l�ll�l�l
10-
TTM OA OMIT AB MOMREO.
Ir PROE PLATFORMROUTING
WITH T7 PN
WEEa-
LVE I/r AM SAA MOUIIND
OWMA ES. AND NORAIL
IVO VD
510E
B, 02
wawa
CEX 3/24/2014
CUSTOMER
OETAIL E
l
Mo—I
BOAC 7H42014
r'w n
urn
RMQP-4096•14K
RMQP-408641K
I
I I
I
I
a• _• ,_,
\Iel
1 a•1
III
-
1
ICI
IE—.,=.MUG
rI
/�
S
2laeBsE
r
2
commi
1
I 7'
201
nity
pmen
t, AGED.. RAMP 1 MM !MI 774120
DESCELCRIPMN OF REVMONE aL BY PATE .j am
10BWMu..rlNNIA.
TOLERANCE NOTES
104sMMMMBSIMt0071E, MMOOWaMM11M.4ARE
ER ▪ 0100EB MOM a2�-00 GOMMaRana
12.10.011.00.40 Nam M A•M7 MONISM 011101Y
MMOAIMEIM0Eae1
aLBIREMA01MM1a MAIM.
AMBI,alA1M1M01 MM .
rs"'"1",'
r LOW PROFILE PLATFORM
WITH 1YIELVE BBIN• ANTENNA MUMS
PIPES, AND 1018000E
t••..a
MSS
CEO ^ 3,2422014
RMQP-4096-HK
REVISION 1111f011Y
WI IO2
d•CUSTOMER BMC7114,2011 RMQP-8096•HK
NOT USED
2
3-SECTOR PLATFORM DETAIL
1
T • •Mobile
•
A
AMERICAN TOWER'
..441k4ISSIk
POWDER RIVER
Engineering Services, LLC
www.powderdverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
B
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
8813 REGISTERED
ARCHITECT
GLENN WALKER.
STATE OF WASHINGTON
r Its 17 la
THESE PIANS AND SPECIFCATIONS. AS INSTRUMENTS OF SERIICE, ARE
AND SHALL REMAIN ME PROPERTY OF POWDER RIVER DEVELOPMENT
SETMCES. LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE
ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL
NOT BE USED BY ANY PERSON OR ENTITY ON OTHER PROJECTS
WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
EQUIPMENT
DETAILS
SHEET NUMBER:
C-6
• •
NSN Flexi Outdoor Cabinet
NSN Flexi Cabinet
NSN Fiexi Outdoor Cabinet
Cabinet will be delivered with custom configuration
DESCRIPTION PART NUMBER
FCOA CABINET
WPUC
(powordfrbfbution unit)
WPMC
twid•band power unkj
470142A
4W955A
4M956A
TECHNICAL SPECIFICATION
Module Type Input Voltage Output Voltage
VVPUC 230 Vac / 36A 44 - 56 VDC / 6000W
WPMC i 200 - 250 Vac / 9A i 44 - SO VDC / 1SOOW
Bottom view
75 mm (3.0 in)
wi
770mm (30.3 in)
770mm (30.3 in)
620 mrn (24.4 in)
t>.
E
E
u7
0 0
0
0
Front side
Isometric view
Front
800 mm
(31.5 in)
500mm (19.7 in)
500 mm
(19.7 in)
with
maintenance
space
Top view
/////////////////////
50 mm (2.0 in)
80 mm
(if windbreaker
is installed)
J '
113177(1676521
Rt: % iV
Los lift.
AUG 27 7niP
CABINET DETAILS
Comm un!:y
DPJe1ppm�l If
1
T • •Mobile
•
A
AMERICAN TOWER"
POWDER RIVER
Engineering Services, LLC
www.powderriverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
8
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
\ 8813 1 REGISTEREDCIUE\\I nxcxnFCT
GLENN WALKER
STATE OF WASHINGTON
THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE
AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT
SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE
ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL
NOT BE USED eY ANY PERSON OR EN111Y ON OTHER PROJECTS
WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
CABINET
DETAILS
SHEET NUMBER:
C-7
EXISTING T—MOBILE
CONCRETE EQUIPMENT
PLATFORM
EXISTING T—MOBILE
PURCELL CABINET
EXISTING T—MOBILE TEST
WELL (TYP)
EXISTING T—MOBILE
FCOA CABINET
LEGEND:
■
EXISTING GROUNDING —\\
RING
GROUND WIRE
CADWELD CONNECTION (EXOTHERMIC WELD)
MECHANICAL CONNECTION
GROUND ROD
TEST WELL
EXISTING T—MOBILE
TO REMAIN (1 TOTAL)
EXISTING T—MOBILE GROUND
ROD S' MIN. (TYP)
NOTE: THE GROUNDING PLAN
PROVIDED HEREIN IS SCHEMATIC BY
NATURE. REFER TO GROUNDING NOTES
ON SHEET GN-2 FOR ADDITIONAL
INFORMATION AND REQUIREMENTS.
PROPOSED #2 AWG
GROUND FROM FCOA
CABINET TO MAIN
GROUND RING
PROPOSED T—MOBILE
FCOA CABINET
EXISDTING #6 AWG GROUND FROM
SECTOR GROUND BAR TO
COLLECTOR GROUND BAR (TYP)
PROPOSED T—MOBILE
NOKIA MFIA AIRSCALE MM
16T16R B25/666 200W ANTENNA
(1 PER SECTOR, 2 TOTAL)
PROPOSED T—MOBILE AHLOA
(1 PER SECTOR, 2 TOTAL)
LEGEND:
EXISTING COLLECTOR
GROUND BAR
GROUND WIRE
• MECHANICAL CONNECTION
EXISTING SECTOR
GROUND BAR
IBM
lomat
NOTE: THE GROUNDING PLAN
PROVIDED HEREIN IS SCHEMATIC BY
NATURE. REFER TO GROUNDING NOTES
ON SHEET GN-2 FOR ADDITIONAL
INFORMATION AND REQUIREMENTS.
PROPOSED #6 AWG GROUND
FROM ANTENNA TO SECTOR
GROUND BAR (TYP)
PROPOSED T—MOBILE
COMMSCOPE FFHH-65C—R3 ANTENNA
(1 PER SECTOR, 2 TOTAL)
EXISTING T—MOBILE TMAs
TO REMAIN
(2 PER SECTOR, 4 TOTAL)
PROPOSED #6 AWG GROUND
FROM AHLOA TO SECTOR
GROUND BAR (TYP)
EXISTING T—MOBILE COVP UNIT
TO REMAIN
EXISTING T—MOBILE
PLATFORM
RECEIVED
AUG 27 2018
Community
Development
EQUIPMENT GROUNDING PLAN (TYPICAL)
2
ANTENNA GROUNDING PLAN (TYPICAL)
SCALE N.T.S
1
T
• •Mobile
•
A
AMERICAN TOWER'
411.11:1;1141L
POWDER RIVER
Engineering Services, LLC
www.pawdeniverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
B
08/09/18
ISSUED FOR REVIEW 90%
RJP
A
06/12/18
ISSUED FOR REVIEW 90%
RJP
8813 REGISTERED
1\\I ARCHITECT
.�
GLENN WALKER
STATE OF WASHINGTON
08 /17 /18
THESE PLANS AND SPECIFICATIONS. IS IMSTRLMEMS OF SEANCE. ME
MO SHALL REMAIN THE PROPERTY OF PONDER RNER CEKLOPMEM
SERVICES. LLC WHETHER 1,E PROJECTS FOR WHICH THEY ME MADE
ARE DER/TED OR NOT. DOSE CRAVINGS MD SPECUICATONS SREE
NOT BE USED RY AM' PERSON OR EMT' ON OTTER PROJECTS
WIFIIOUT PR/OR *RTEN CONSENT OF DIE ENGINEER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
GROUNDING
PLANS
SHEET NUMBER:
G-1
4"x24"x1/4" TINNED
COPPER GROUND BAR
(HAGER OR APPROVED
EQUIVALENT)
#2 AWG SOLID TINNED
COPPER CONDUCTOR TO
MAIN GROUND BAR OR
EXISTING GROUND RING
(TYP.). CADWELD TO BUS
BAR AND GROUND RING
COPPER BONDING CONDUCTORS TO
CABLES AND EQUIPMENT. SEE
GROUNDING PLANS FOR DETAILS
3/8" BOLT AND
HARDWARE (TYP.)
CHERRY BUS BAR
INSULATOR (TYP OF
2). NOT USED WHEN
DIRECT ATTACHMENT
TO TOWER STEEL IS
REQUIRED
WALL -MOUNT BRACKET
OR ANGLE ADAPTER
(AS REQUIRED)
NOT USED
5
NOT USED
3
GROUND BAR DETAIL
SCALE: N.T.S.
1
NOTES:
1. CADWELD "TYPES" SHOWN ARE EXAMPLES. CONSULT WITH
CONSTRUCTION MANAGER FOR SPECIFIC TYPES OF
CADWELDS TO BE USED FOR THIS PROJECT.
2. CONFIRM WITH TOWER OWNER THAT THE USE OF
CADWELDS IS ACCEPTABLE, PRIOR TO INSTALLATION.
TYPE 2-YA-2
TYPE GT
TYPE VS
TYPE YA-2
TYPE YGHC
AUG 27, th
Community
Development
NOT USED
6
NOT USED
4
CADWELD CONNECTION TYPES
2
T
• •Mobile
•
A
AMERICAN TOWER°
.4414,16Sk
POWDER RIVER
Engineering Services, LLC
www.powdeniverdev.com
BUSINESS LICENSE #: 3004
REVISIONS
REV
DATE
DESCRIPTION
INT
0
08/17/18
100% CONSTRUCTION
RJP
B
08/09/18
ISSUED FOR REVIEW 907E
RJP
A
06/12/18
ISSUED FOR REVIEW 907E
RJP
8813 REGISTERED
1\\I ARCHITECT
GLENN WALKER
STATE OF WASHINGTON
Oa/n n8
THESE PMJWS AND SPE01Ex:0TONS. AS INSTRUYDJTS 0f SERVICE. ARE
AND SHALL R(YNN THE PROPERTY CR POWDER RIVER DEPLOYMENT
WHAMS. LLC WHETER THE PROJECTS 00R WHICH THEY ARE 0000
ARE MOOED 0R NOT. THESE OMWDILS AHD SPEgi10AT10N5 SHELL
NOT BE USED Hf ANY PERSON OR ENTRY ON OTHER PROJECTS
WITHOUT PRIOR WRRTEN CdLSENT 0f THE ENC0N(ER.
SITE INFORMATION
T-MOBILE #: SE03858A
ATC #: 414339
18700 ORILLIA RD. S
SEATTLE, WA
98188
SHEET TITLE:
GROUNDING
DETAILS
SHEET NUMBER:
G-2