Permit PL18-0079 - AT&T WA6158 ROXBURY 5C+6C - WIRELESS FACILITY
AT&T WA6158 ROXBURY 5C+6C 0423049130 PARENT FILE PL18-0079 THIS FILE L18-0093 WIRELESS FACILITY/TYPE 1 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director November 26, 2018 NOTICE OF DECISION TO: Charlies Li, Glotel Inc., (OBO AT&T) Seattle City Light King County Assessor, Accounting Division Agencies with Jurisdiction This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. I. PROJECT INFORMATION Project File Number: L18-0093; PL18-0079 Applicant: Charles Li, Glotel Inc., OBO AT&T Type of Permit Applied for: Type 1 Wireless Facilities Permit Project Description: The applicant is proposing modifying the existing Seattle City Light lattice tower by replacing three (3) existing panel antennas, six (6) TMAs, and the six (6) 7/" coax with (6) 1-5/8" coax. The project also qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which requires the City to approve any eligible facilities request for a modification of an existing tower or base station that does not substantially change the physical dimensions of such tower or base station. This proposal is not considered a substantial change under the Tukwila Municipal Code 18.58.200.7, and falls within the guidelines for an eligible facilities modification. Location: Parcel 0423049130 in Tukwila, WA 98168 Associated Files: PL18-0079 Comprehensive Plan Manufacturing Industrial Center/Heavy Industrial (MIC/H) Designation/Zoning District: Manufacturing Industrial Center/Heavy Industrial (MIC/H) II. DECISION SEPA Determination: The City SEPA Responsible Official has determined that this application does not require a SEPA threshold determination because it is categorically exempt. Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Decision on Substantive Permit: The Community Development Director has determined that the application for a Wireless Telecommunication Facility does comply with applicable City and state code requirements and has approved this application. III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code §18.104.010. Other land use applications related to this project may still be pending. No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the conditions which were imposed by the MDNS decision or the failure of the Department to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner. A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King County Superior Court from the Hearing Examiner's decision. IV. PROCEDURES AND TIME FOR APPEALING To appeal the Community Development Director decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this Decision. The requirements for such appeals are set forth in Tukwila Municipal Code Ch. 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing party's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. S. Appeal fee per the current fee schedule, additional hourly charges may apply. In addition, all hearing examiner costs will be passed through to the appellant. Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the Hearing Examiner based on the information presented to the Community Development Director, who made the original decision. No new evidence or testimony will be permitted during the appeal hearing. Parties will be allowed to present oral argument based on the information presented to the Community Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW Ch. 36.70C. An appeal challenging a DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the subject property. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Meredith Sampson, who may be contacted at 206-431-3661 or Meredith.Sampson@TukwilaWA.gov for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. L Depart �-nt of Community Development City of kwila Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director Staff Report PREPARED November 26, 2018 NOTIFICATION: Notification is not required for a Type 1 land use application. FILE NUMBER: L18-0093; PL18-0079 APPLICANT: Charles Li, Glotel Inc., OBO AT&T PROPERTY OWNER: Seattle City Light REQUEST: Approval of a Type 1 Wireless Telecommunications Facilities Permit to modify the existing Seattle City Light lattice tower by replacing three (3) existing panel antennas, six (6) TMAs, and the six (6) 7/" coax with (6) 1-5/8" coax. LOCATION: Parcel 0423049130 in Tukwila, WA 98168 ASSOCIATED PERMITS: Electrical permits issued through the City of Tukwila will be required for service alteration for any other electrical service work that is anticipated but not noted on the plans, per article 85.12 (B), Washington electrical code. Building and mechanical permits are required for scope of work stated on the submitted plans. SEPA DETERMINATION: Exempt COMPREHENSIVE PLAN Manufacturing Industrial Center/Heavy Industrial (MIC/H) DESIGNATION: ZONE DESIGNATION: Manufacturing Industrial Center/Heavy Industrial (MIC/H) STAFF: Meredith Sampson, Assistant Planner ATTACHMENTS: Project Plans for Permit L18-0093 FINDINGS Vicinity/Site Information Project Description The applicant is proposing modifying the existing Seattle City Light lattice tower by replacing three (3) existing panel antennas, six (6) TMAs, and the six (6) 7/" coax with (6) 1-5/8" coax. Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Page 2 • • The project also qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which requires the City to approve any eligible facilities request for a modification of an existing tower or base station that does not substantially change the physical dimensions of such tower or base station. This proposal is not considered a substantial change under the Tukwila Municipal Code 18.58.200.7, and falls within the guidelines for an eligible facilities modification. Existing Development This telecommunications facility is preexisting. Surrounding Land Uses The property is zoned Manufacturing Industrial Center/Heavy Industrial (MIC/H). Parcels to the north, east, and south are also zoned MIC/H. WA-99 lies to the west. Background In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.71) to the Zoning Code. The chapter provides location and design requirements for the placement of WCF within the City of Tukwila. In 2016 the city adopted amendments to this ordinance in compliance with the Federal Spectrum Act. Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Page 3 Location Selection Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co - locations and utilizing existing structures are favored over the development of new standalone WCF within the City. TABLE A Type of Permit Required, Based onr Type of Wireless Communication Facility Zoning(1) Type of Facility Residential Commercial industrial Adding antemas to an ensting immix utiity Pale Type 1171 Type 1RI Type 1Pi Eligible facilities modificalion Type 1 Type t Type 1 Utility pola c-loca ton Type 2 Type 2 Type 2 Concealed bullring attached Type 20 Type 291 Type 1 l en -concealed building attached Type 2M1 Type 2 Type 1 New tower or height adjustment request Type PI Type 3 Type 3 (1) Zoning for any private/public property or right-of-way Residential — LDR, MDR, or HDR Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C/LI or TVS Industrial - LI, HI, MIC/L, or MIC/H (2) Provided the height of the tower does not increase and the square footage of the enclosure area does not increase. (3) An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.150. The applicant is proposing modifying the existing Seattle City Light lattice tower by replacing three (3) existing panel antennas, six (6) TMAs, and the six (6) 7/" coax with (6) 1-5/8" coax. Design Standards The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below indicates if the applicant's proposal complies with required standards. Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Page 4 Table 1 (See TMC 18.58.070 for further details) General Requirements Project does comply Project does not comply Not Applicable Notes 1. Generators or other devices which will create noise must comply with TMC 8.22 regarding noise. X 2.Business License Requirement X 3.Only safety signage must be placed on the WCF. X 4. Accommodations for parking for maintenance personal must be provided. X This modification does not affect parking. 5. Towers shall either maintain a galvanized steel finish or be painted a neutral color so as to reduce its visual obtrusiveness. X Tower already exists. 6. The design of all buildings and ancillary structures shall use materials, colors, textures, screening, and landscaping that will blend the tower facilities to the natural setting and built environment. X No new structures added. 7. Antennas shall have the same color scheme as the structure they are located on. X 8. WCF poles and towers shall only have safety lights if required by a government agency. X 9. No advertising is permitted on WCF X No advertising is proposed. 10. Each service provider shall be limited to an equipment enclosure of 360 square feet. X Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Page 5 Table 2 (See TMC 18.58.090 for further details Adding Antennas to Existing WCF Towers Development Standards Project Does Comply Project Does Not Comply Not Applicable Notes 1. The height must not exceed the height that was approved at the time of the original monopole construction X 2. Antenna shall be pained to match the color scheme of the tower X 3. No limit to the number of antennas the may be located at an existing tower X 4. Feed lined and coaxial cables are located within the tower X 5. Any exposed feed lines or cables will be painted to match the tower X 6. Cabinet equipment is located within the equipment enclosure X 7. Setbacks will not apply when installing antennas to an existing tower X Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Page 6 CONCLUSIONS 1. The proposed modifications to the existing WCF will not significantly alter the conditions that currently exist and will not be materially detrimental to the public welfare or injurious to property or improvements in the vicinity. 2. As demonstrated in Table 1, the project meets all applicable development standards for a Type 1 WCF. 3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian circulation, building or site design. 4. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan. S. The project also qualifies as an Eligible Facilities Modification under § 6409 of the FCC's Spectrum Act, which requires the City to approve any eligible facilities request for a modification of an existing tower or base station that does not substantially change the physical dimensions of such tower or base station. RECOMMENDATIONS The recommendation to the Director of Community Development is to approve this application for a Type 1 Wireless Telecommunications Facility permit. INFORMATIONAL ITEMS A City of Tukwila electrical permit is required for service alteration. A building and mechanical permit are required for the site work. Please note that the installation of an emergency power disconnect switch is required for Fire Department use. Contact lien Hayman at to get more information about permit requirements for the power disconnect switch. Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director Affidavit of Distribution Project Name: AT&T WA6158 ROXBURY 5C+6C Project Number: PL18-0079 Associated File Number(s): L18-0093 Date Mailed: 11/27/2018 Mailing requested by: MEREDITH SAMPSON Mailer's signature: SM ❑ Board of Adjustment Agenda Packet ❑ Board of Appeals Agenda Packet ❑ Determination of Non -Significance ❑ Determination of Significance & Scoping Notice ❑ Mitigated Determination of Non - Significance ❑ Notice of Action ❑ Notice of Application Parties of Record: ❑ Notice of Application for Shoreline Mgmt Permit ® Notice of Decision O Notice of Public Hearing O Notice of Public Meeting O Official Notice O Other: SEPA CHECKLIST ❑ Shoreline Mgmt Permit ❑ Short Subdivision Agenda HANDLING 1, 2 CHARLES LI 1 SEATTLE CITY LIGHT 1 Christie.Most@kingcounty.gov 1 ANA.LE@TUKWILAWA.GOV 1 tukwilahistsociety@tukwilahistory.org 1 rcwieser@comcast.net 1 NoD 2 STAFF REPORT CLI@GLOTEL.COM ENVIRONMENT & SAFETY DI PO BOX 34023 SEATTLE W 98124 0400 City of Tukwila Department of Community Development File Number L18-0093 PL18-0079 LAND USE PERMIT ROUTING FORM TO: IIIBuilding []Planning []Public Works []Fire Dept. n Police Dept. n Parks/Rec Project: AT&T WA1658 Roxbury 5C +6C Address: 11041 Tukwila International Blvd Date 10/4/18 transmitted: Response requested by: ASAP Staff Meredith Sampson coordinator: Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60-day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) 4,G-e_ `rliw 11 ...k4-- i.vts-1 2A k Plan check date: Comments Update date: prepared by: RECEIVED September 26, 2018 SEP 27 2018 City of Tukwila Community Department of Community Development Development 6300 Southcenter Blvd Tukwila, WA 98188 Gb teL;, >Integrity Deliveredd' Request for Modification to Existing AT&T Wireless Telecommunication Facility Site Address: 10710 West Marginal Way S, Tukwila, WA 98168 AT&T Project Name: WA6158 Roxbury 5C+6C Dear Reviewing Parties: On behalf of New Cingular Wireless PCS, LLC ("AT&T"), Glotel is pleased to submit this Type 1 application to modify an existing AT&T facility on a Seattle City Light lattice tower at 10710 West Marginal Way S located within the MIC/H zone of Tukwila. The proposed modification includes the replacement of (3) existing panel antennas, the replacement of (6) TMAs, and the replacement of (6) 7/8" coax with (6) 1-5/8" coax. Please refer to enclosed Site Plans for more details. The legal description of the parcel on which the existing facility is located is as follows: C OF S TRANS LN R/W OVER GL 4 & 5 TGW SE 1/4 LESS ST HWY TGW 250 FT R/W OVER TRACT 55 OF MOORES FIVE -ACRE TRACTS & VAC G FRAIEGER RD LESS ST I-IWY. The antenna modification project has a valuation of $30,000. Due to the scope of work, this proposed modification qualifies for review under the guidelines of the Federal Communication Commission's 6409(a) rule. The provisions of section 6409(a) are as follows: Sec. 6409. WIRELESS FACILITIES DEPLOYMENT (a) FACILITY MODIFICATION IN GENERAL. Notwithstanding section 704 of the Telecommunications Act of 1996 (Public Law 104-104) or any other provision of law, a State or local government may not deny, and shall approve, any eligible facilities request for a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station. a. ELIGIBLE FACILITIES REQUEST. For purposes of this subsection, the term "eligible facilities request" means any request for modification of an existing wireless tower or base station that involves: i. Collocation of new transmission equipment, ii. Removal of transmission equipment; iii. Replacement of transmission equipment. b. APPLICABILITY OF ENVIRONMENTAL LAWS. Nothing in paragraph (1) shall be construed to relieve the Commission from the requirements of the National Historic Preservation Act or the National Environmental Policy Act of 1969. The overall purpose of Section 6409 and the FCC's new rule is to streamline the permitting process and expedite the deployment of broadband services. The new rule only applies to modifications of existing wireless facilities that do not substantially change the existing facility. 1 As shown below, this AT&T proposed modification is not a substantial change and meets all necessary standards to be considered an eligible facility under Section 6409 and TMC 18.58.200. Component Federal Section 6409 Limits AT&T's Proposed Modification _Component height of original structure 20 feet or less There is no proposed increase in height to the existing structure. The height will remain at 156'-8". Antennas extending horizontally from edge of structure 20 feet or less The replacement antennas will be mounted to sector frames, which do not extend more than 5' from the edge of the structure. Additional equipment cabinets 4 or fewer, with no cabinets larger than the existing cabinets No additional equipment cabinets are being proposed. New equipment will be placed within existing cabinets. The replacement antennas will be located on the existing sector frames and ancillary equipment will be mounted behind the antennas. The replacement coax will be installed in the same manner as the smaller coax. Additional ground equipment will be added within existing equipment cabinets. No excavation will occur outside the existing lease area, and no existing concealment efforts will be defeated by the proposal. AT&T is also not proposing to add or modify any noise generating equipment. The modification is exempt from SEPA. Conclusion As this AT&T proposal qualifies as an eligible facilities request under Section 6409 regulations, we respectfully request that the City of Tukwila approves this modification as presented. Our goal is to work with the City to expedite this review. In order to assist with the review, the following information is included with this application: 1 x Application Checklist - 5x Site Plans/Construction Drawings 11" x 17" - 5x Application Form - 5x Affidavit of Ownership and Hold Harmless Form If any additional information is needed to do so, please let me know. Thank you for your time and consideration. Sincerely, Charles Li Site Development Specialist Glotel, Inc phone: (425) 765-6220 email: cli(glotel.com olARV I �, CEP B � v41/4 36 ,ti.�► �.` .lE OF W AS.��.`� '�,I,,,nnIt«'�o CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY STATE OF WASHINGTON ss COUNTY OF KING The undersigned being duly sworn and upon oath states as follows: 1. I am the current owner of the property which is the subject of this application. 2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my knowledge. 3. The application is being submitted with my knowledge and consent. 4. Owner grants the City, its employees, agents, engineers, contractors or other representatives the right to enter upon Owner's real property, located at 10710 West Marginal Way S, Tukwila, WA 98168 for the purpose of application review, for the limited time necessary to complete that purpose. 5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City. 6. Non -responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without refund of fees. RECEIVED SEP 27 2018 Community Development EXECUTED at e4...1-/ (.6 (city), IN A (state), on a ( 11 , 20 / Lj"I+fle (�r�ivLe b41 �et (13r;lt 1( //I 1.4LffIle Z' Q �r 1 LPy�t (Add,�0 ress) 6 6( f ,a65 (Phone Number) (Signature) ahbrmart �� Tj to me known to be the individual who executed the foregoing instrwnent and acknowledged at he/she signed the same as his/her voluntary act and deed for the uses and purposes menti !/ ���!! g SUBSCRI]C'TOO'$EFORE ME ON THIS C94-1 D�i' OF/ t her , 20 On this day personally appeared before me NOTARY �ij LI in and for t State o� Washington PU �.' : residing .:' Q Al-1 C C A._ } My Commission expires on 1 /1 l [ Y W.\@SHAREPOINT FOLDER RESTRUCTURE\ Reference\APPLICATIONS - Land Use Apps & Handouts\CURRENT LAND USE APPLICATIONS\DRAFT Wireless Communication Faciliry.docx COMPLETE APPLICATION CHECKLIST The materials listed below must be submitted with your application. You may request a waiver from items on the checklist that are not applicable to your project. Please discuss this waiver request with City staff either at a pre - application meeting or at the time of application submittal. Application review will not begin until it is determined to be complete. Within 28 days of receiving your application, City staff will determine if it is complete based on the attached checklist. If not complete City staff will mail you a letter outlining what additional information is needed. If you do not submit requested materials within 90 days from the City's request for additional information the City may cancel your application. RECEIVED Check items submitted with application Information Required. - Additional materials may be required. SEP 27 2018 Community Development APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities. x 1. Application Checklist (1 copy) indicating items submitted with application. x 2. Completed Application Form and drawings (5 copies). x 3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site map, architectural elevations, method of attachment, proposed screening, location of proposed antennas, and all other information which accurately depicts the proposed project. Minimum size is 8 1/2" x 11". Plans shall be no greater than 24" x 36". 4. Application Fee: See Land Use Fee Schedule. x 5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property (1 copy attached). 6. SEPA Environmental Checklist. SEPA is not required when the facility: i) Is a microcell and is to be attached to an existing structure that is not a residence or school and does not contain a residence or a school; ii) Includes personal wireless antennas, other than a microcell, and is to be attached to an existing structure (that may be an existing tower) that is not a residence or school and does not contain a residence or school, and the existing structure to which it is to be attached is located in a commercial, industrial, manufacturing, forest or agriculture zone; or iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a commercial, industrial, manufacturing, forest, or agricultural zone. x 7. A letter from the applicant describing the proposed project and describing compliance with the City's Code requirements stated in TMC Section 18.58. Include statement whether the proposal is considered a "substantial change" or not as defined by the FCC rules and TMC Section 18.58.200. 8. Sensitive Area studies and proposed mitigation (if required). 9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating compliance with TMC Section 8.22, "Noise". If the application requires a Type 2 review these additional items are needed: 10. Four sets of photo simulations that depict the existing and proposed view of the proposed facility; 11. Materials board for the screening material; 12. Landscaping plan; 13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal requirements for allowed emissions; 14. If the facility is located within a residential zone, a report from a radio frequency engineer explaining the need for the proposed wireless communication facility at that location. Additionally, W:\©SFIAREPOINT FOLDER RESTRUCTURE\ Reference\APPLICATIONS - Land Use Apps & Handouts\CURRENT LAND USE APPLICATIONS\DRAFT Wireless Communication Facility.docx Check items submitted with application Information Required. - Additional materials may be required. the applicant shall provide detailed discussion on why the wireless communication facility cannot be located within a commercial or industrial zone. If the application requires a Type 3 review these additional items are needed: 15. A narrative responding to the criteria at TMC Section 18.58.060. 16. The radio frequency engineer report shall include a discussion of the information required under TMC Section 18.58.070. The report shall also explain why a tower must be used instead of any of the other location options outlined in Table A. 17. Engineering Plans for the proposed tower. 18. A vicinity map depicting the proposed extent of the service area. 19. A graphic simulation showing the appearance of the proposed tower and ancillary structures and ancillary facilities from five points within the impacted vicinity. Such points are to be mutually agreed upon by the Director of DCD and applicant. All plans and photo simulations shall include the maximum build -out of the proposed facility. 20. Evidence of compliance with Federal Aviation Administration (FAA) standards for height and lighting and certificates of compliance from all affected agencies. 21. Evidence that the tower has been designed to meet the minimum structural standards for wireless communication facilities for a minimum of three providers of voice, video or data transmission services, including the applicant, and including a description of the number and types of antennas the tower can accommodate. PUBLIC NOTICE MATERIALS: (Necessary for Type 3) 22. Payment of notice board fee (see Land Use Fee schedule) to FastSigns Tukwila OR provide a 4' x 4' public notice board on site within 14 days of the Department determining that a complete application has been received (see Public Notice Sign Specifications Handout). 23. Pay the fee as established by the Land Use Fee Schedule for generating mailing labels; OR provide an excel spreadsheet of mailing labels for all property owners and tenants (residents and businesses) within 500 feet of the subject property. Each unit in multiple family buildings e.g. apartments, condos, trailer parks --must be included. Once your project is assigned to a planner, you will be required to provide an electronic copy of the mailing label spreadsheet in the following format: Name, Street Address, City St Zip, with each of these fields as an individual column: Name Street Address City, St, Zip Mr. Smith 1234 Park Ave S Tukwila WA 98188 PLEASE NOTE: Regardless of whether you pay the City to generate the mailing labels or you provide them, there is an additional fee for postage and material as listed under Public Notice Mailing Fee on the Land Use Fee Schedule. Payment of this fee is due prior to issuance of the decision and you will receive a separate bill for this fee. - 24. If providing own labels, include King County Assessor's map(s) which shows the location of each property within 500 ft. of the subject lot. RECEIVED SEP 27 2018 Community Dev lAWegt WA@SHAREPOINT FOLDER RESTRUCTUREVteference\APPLICATIONS - Land Use Apps & Handouts\CURRENT LAND USE APPLICATIONS\D A re s Communication Facility.docx Cash Register Receipt City of Tukwila DESCRIPTIONS ProjectTRAK ACCOUNT QUANTITY PAID $677.02 118-0093 Address: Apn: 0423049130 $677.02 Credit Card Fee $19.72 Credit Card Fee R000.369.908.00.00 0.00 I $19.72 TECHNOLOGY FEE $31.30 TECHNOLOGY FEE R000.322.900.04.00 0.00 $31.30 WIRELESS $626.00 TYPE 1 TOTAL FEES PAID BY RECEIPT: R15499 R000.345.810.00.00 0.00 $626.00 $677.02 Date Paid: Thursday, September 27, 2018 Paid By: SYLVIA BUTLER Pay Method: CREDIT CARD 012202 Printed: Thursday, September 27, 2018 10:57 AM 1 of 1 CSYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 09/27/2018 10:56:26 AM CREDIT CARD SALE VISA CARD NUMBER: **********0512 K TRAN AMOUNT: $677.02 APPROVAL CD: 012202 RECORD #: 000 CLERK ID: Shana INVOICE #: L18-0093 X (CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic.convergepay. comNirtualMerchant/transaction.do?di spatchMethod=printTra... 9/27/2018 Page 2 of 2. CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 09/27/2018 10:56:26 AM CREDIT CARD SALE VISA CARD NUMBER: **********0512 K TRAN AMOUNT: $677.02 APPROVAL CD: 012202 RECORD #: 000 CLERK ID: Shana INVOICE #: L18-0093 Thank you! Customer Copy https://classic.convergepay.comNirtualMerchant/transaction.do?dispatchMethod=printTra... 9/27/2018 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 WIRELESS TELE- COMMUNICATION FACILITIES APPLICATION FOR STAFF USE ONLY Planner: File Number: 6— /g ' a0 F3 Application Complete Date: Project File Number: p LI ?-' o 7 Application Incomplete Date: Other File Numbers: NAME OF PROJECT/DEVELOPMENT: AT&T WA6158 Roxbury 5C+6C BRIEF DESCRIPTION OF PROJECT: Replacement of 3 antennas, 6 TMAs, and 6 coax on existing facility CIRCLE TYPE : CYPE� TYPE 2 TYPE3 Public Hearing Notices and Hearing Examiner Fees Apply. LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. S, Nearest intersection is 27th Ave S and S 102nd St //4V/ w/L/t- /N TL Aftc/rEcz_s., waTics. r-//E /,vcoee£�% LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). 0423049130 DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent. Name: Charles Li Address: 3380 146th PI SE, Ste 102, Bellevue, WA 98007 Phone: 425-765-6220 E-mail: cli@glotel.com Digitally signed by Charles Li 9/26/18 Signature: Charles LrDate:2018.09.26 16:58:58 Date: -07'00' RECEIVED SgP 27 2018 W:\@SI1AREPOINT FOLDER RESTRUCTURE\Reference\APPLICA LIONS - Land Use Apps & Handouts\CURRENT LAND USE APPLICATIONS\DRAFT treless Communication Facility.docx Community Development THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AT&T MOBILITY SERVICES IS STRICTLY PROHIBITED. • at&t Mobility III III 777 VICINITY MAP Av.a'ID, Partn:�' iemSITE J'b NAPA Auto Part: mine Pans Corm,' TRITE NORTH DRIVING DIRECTIONS START FROM REGIONAL OFFICE: TURN RIGHT ONTO 164th AVENUE NE, GO TURN RIGHT ON BEAR CREEK PKWY, GO TURN LEFT ON LEARY WAY, GO TAKE THE RAMP ONTO WA-520 W, GO TAKE THE EXIT ONTO 1-405 S TOWARD RENTON. GO TAKE THE EXR TOWARD 1-5 N, GO KEEP RIGHT AT THE FORK AND FOLLOW SIGNS FOR SEATTLE/I-5 AND MERGE ONTO 1-5 N. GO TAKE EXIT #156 FOR WA-599 TOWARD W MARGINAL WAY / TUKWILA, GO CONTINUE ON WA-599, GO 2.4 MI. TAKE THE W MARGINAL PL EXIT, GO TURN RIGHT ON 27th AVENUE 5, GO ARRIVE AT 10710 WEST MARGINAL WAY S, TUKWILA, WA 98168 220 FT 0.3 MI 0.3 MI 5.0 MI 14.7 MI 197 FT 1.2 MI 0.5 MI 0.1 MI 0.2 MI • SITE INFORMATION PROJECT DESCRIPTION; AT&T MOBILITY PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY BY REPLACING (3) EXISTING PANEL ANTENNAS WITH (3) NEW PANEL ANTENNAS. (6) EXISTING TMA'S MOUNTED BEHIND ANTENNAS AND (6) 7/8" COAX WITH (6) 1-5/8" COAX ON THE TOWER. ALSO REPLACING (6) EXISTING RRH WITH (6) NEW RRH UNITS AT GROUND LEVEL CODE INFORMATION; ZONING CLASSIFICATION: BUILDING CODE: CONSTRUCTION TYPE: OCCUPANCY: JURISDICTION: PROPOSED BUILDING USE: SITE LOCATION; LATITUDE: LONGITUDE: TOP OF STRUCTURE (AGL): 156'-8" BASE OF STRUCTURE (AMSL): 18.251' MIC/H 2015 IBC 98 U, S-2 CITY OF TUKWILA UNMANNED TELECOMMUNICATIONS PARCEL NUMBER(S): 0423049130 LIM 3801AODBHO PACE#; MRWOR029562 EAL 10013280 SITE TYPE; 158'-6" TRANSMISSION TOWER 47 30' 23.5" N (47.5065) 127 17' 58.4` W (-122.2995) GENERAL INFORMATION; 1. PARKING REQUIREMENTS ARE UNCHANGED 2. TRAFFIC IS UNAFFECTED 3. SIGNAGE IS NOT PROPOSED FACILITY J LEGAL DESCRIPTION C OF S TRANS LN R/W OVER GL 4 & 5 TGW SE 1/4 LESS ST HWY TGW 250 FT R/W OVER TRACT 55 OF MOORES FIVE -ACRE TRACTS & VAC G FRAIEGER RD LESS ST HWY WA6158 ROXBURY LTE 5C+6C 10710 WEST MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY PROJECT CONTACTS APPLICANT. NEW CINGULAR WIRELESS PCS, LLC (AT&T) 16221 NE 72ND WAY, RTC 3 P.O. BOX 97061 REDMOND. WA 98052 PROJECT ENGINEER' GLOTEL INC 3380 146TH PL SE. SUITE 102 BELLEVUE, WA 98007 CONTACT: RYAN MCDANIEL, P.E. PROJECT MANAGER: MASTEC NETWORK SOLUTIONS CONTACT: PAM ROY A&E MANAGER: MASTEC NETWORK SOLUTIONS CONTACT: PATRICK WINTERS STRUCTURAL ANALYSIS; CITY OF SEATTLE SEATTLE CITY UGHT REAL ESTATE SERVICES 700 5TH AVE. SUITE 3000 SEATTLE, WA 98104 CONTACT: DOUG HABERMAN PH: (206) 733-9138 PROPERTY OWNER: CITY OF SEATTLE SEATTLE CITY UGHT REAL ESTATE SERVICES 700 5TH AVE, SUITE 3000 SEATTLE, WA 98104 CONTACT: DOUG HABERMAN PH: (206) 733-9138 TOWER OWNER• CITY OF SEATTLE SEATTLE CITY LIGHT REAL ESTATE SERVICES 700 5TH AVE, SUITE 3000 SEATTLE. WA 98104 CONTACT: DOUG HABERMAN PH: (206) 733-9138 SITE ACQUISITION; MASTEC NETWORK SOLUTIONS CONTACT: TONY PULED PHONE: (847) 463-5939 PERMITTING; MASTEC NETWORK SOLUTIONS CONTACT: DREW PARKER PHONE: (630) 634-4932 CONSTRUCTION MANAGER; MASTEC NETWORK SOLUTIONS CONTACT: MIKE SUTHERBY PHONE: (231) 527-5269 100% 5C+6C CONSTRUCTION DRAWINGS DRAWING INDEX T-1 TITLE SHEET G-1 GENERAL NOTES A-1 SITE PLAN A-2 ENLARGED SITE PLAN A-3 EXISTING & PROPOSED EOUIPMENT LAYOUT A-4 EXISTING & PROPOSED SOUTHEAST ELEVATION A-5 RF DETAILS RF-1 EXISTING & PROPOSED ANTENNA CONFIGURATIONS E-1 SCHEMATIC GROUNDING PLAN E-2 GROUNDING DETAILS DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER, SCALES SHOWN ON PLANS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE ENGINEER AND CARRIER OF ANY ERRORS OR OMISSIONS. APPROVAL/SIGN OFF CONSULTANT GROUP SIGN OFF DATE SIGNATURE AT&T SIGN OFF DATE SIGNATURE CONSTRUCTION MANAGER RF ENGINEER LANDLORD'S REPRESENTATIVE INTERCONNECT 6 ( , ®i/7^• PROJECT MANAGER OPERATIONS �,I/r fit ��!!" � ,r> �� SITE ACQUISITION COMPLIANCE PERMITTING CONSTRUCTION MANAGER PROJECT MANAGER CCImmuniry t DeVe\0Pnlcr\ REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED Giotel. >Integrity DeliveredTM J -:-MasTec Network Solutions RFDS: V 2.0. DATED: 02/01/2018 WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY EXPIRES 01-09-2019 j REVISIONS REV. DATE DESCRIPIK1N 8Y A 0]/25/18 ISSUED FOR 90X CD RENEW TR 0 09/30/15 ISSUED FOR I00X CONSTRUCTION WJR TITLE TITLE SHEET SHEET T-1 CGLOTEL PROJECT #: J5568J U 2 0 0 0 OF CONSTR 0 LIMITS OF LIABILITY: CLOTEL HAS MADE EVERY EFFORT TO CREATE COMPLETE AND ACCURATE CONTRACT DOCUMENTS WITH THE BEST INFORMATION AVAILABLE AT THE TIME OF THEIR COMPLETION. CONTRACTORS ARE CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE CONTRACT DOCUMENTS MAY OCCUR AND SHALL NOT EXCUSE THE CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THE DOCUMENTS. REFERENCE ADMINISTRATIVE REQUIREMENTS. CONTRACT DOCUMENTS: 1. THE CONTRACT DOCUMENTS INCLUDE THE AGENCY APPROVED PROJECT SPECIFICATIONS, PLANS. AND THEIR LATEST REVISIONS. ADDENDA. AND CLARIFICATIONS. THE CONTRACT DOCUMENTS MAY ALSO INCLUDE NETWORK CARRIER STANDARDS FOR INSTALLATION OF TELECOMMUNICATIONS EQUIPMENT. 2. THE CONTRACTOR SHALL KEEP A MINIMUM OF ONE SET OF CONTRACT DOCUMENTS ON FILE IN THE PRWECT OFFICE AT THE JOB SITE. COPIES OF THE PROJECT DOCUMENTS USED BY SITE STAFF SHALL BE UP TO DATE WITH THE PROJECT OFFICE COPY. 3. THE CONTRACTOR SHALL NOTIFY THE PROJECT TEAM OF ANY ERRORS, OMISSIONS, AND INCONSISTENCIES FOUND IN THE CONTRACT DOCUMENTS. THE NOTIFICATION SHALL BE GIVEN BOTH VERBALLY AND IN WRITING WITHIN 24 HOURS OF DISCOVERY. 4. IF AN ERROR OR OMISSION IN THE PROJECT DOCUMENTS REOUIRES RECTIFICATION, THE CONTRACTOR SHALL SUBMIT A PROPOSAL TO THE PROJECT TEAM TO RECTIFY THE ISSUE. THE PROPOSAL MUST BE APPROVED PRIOR TO WORK. 5. THE CONTRACT DRAWINGS ARE PREPARED TO SCALE WITH THE BEST KNOWLEDGE OF THE SITE GIVEN TO GLOTEL. WHERE DIMENSIONS ARE NOT SHOWN IN THE DRAWINGS, THE CONTRACTOR SHOULD CLARIFY WITH THE PROJECT TEAM WHEN THE INFORMATION IS CRITICAL TO PROPER INSTALLATION. 6. THE CONTRACTOR SHALL DOCUMENT ALL CHANGES AND SUBSTITUTIONS ON THE PROJECT OFFICE COPY OF THE CONTRACT DOCUMENTS. 7. WHEN FABRICATION OF STRUCTURAL ITEMS ARE REQUIRED, IT MAY BE NECESSARY TO SUBMIT SHOP DRAWINGS FOR REVIEW BY CLOTEL. SEE STRUCTURAL NOTES. 8. DEFERRED SUBMITTALS ARE REQUIRED FOR MATERIALS TO BE PROVIDED BY THE CONTRACTOR. WHERE MATERIALS IN THE PLANS ARE DESIGNATED AS PROVIDED BY CONTRACTOR, THE CONTRACTOR SHALL SUBMIT THE PREFERRED MATERIAL TO THE PROJECT TEAM FOR REVIEW AND APPROVAL PRIOR TO WORK. ADMINISTRATIVE REQUIREMENTS: 1. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS REQUIRED (INCLUDING FEES) TO COMPLETE THE WORK DESCRIBED BY THE CONSTRUCTION DOCUMENTS. 2. PRIOR TO BIDDING, THE CONTRACTOR 15 RESPONSIBLE FOR REVIEW OF THE PROJECT sat AND CONTRACT DOCUMENTS TO UNDERSTAND THE DESIGN AND CONDITIONS AFFECTING THE WORK TO BE PERFORMED. ANY ERRORS, OMISSIONS, AND DISCREPANCIES MUST BE SUBMITTED TO THE PROJECT TEAM VERBALLY AND IN WRITING. 3. THE CONTRACTOR SHALL PROVIDE A WARRANTY FOR WORK FOR A PERIOD OF ONE YEAR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY ALL FAULTY, INFERIOR, AND/OR IMPROPER MATERIALS, DAMAGED GOODS, AND/OR FAULTY WORKMANSHIP. ALL ROOFING AND WATERPROOFING MUST BE WARRANTED FOR A PERIOD OF IWO YEARS. THE PERIOD BEGINS AT SUBSTANTIAL COMPLETION OF THE PROJECT. 4. THE CONTRACTOR SHALL PROVIDE A COPY OF LICENSE AND INSURANCE TO THE TELECOMMUNICATIONS CARRIER. SITE SAFETY: 1. THE CONTRACTOR SHALL PROVIDE OSHA COMPLIANT PROTECTION FOR THE SAFETY OF THE SITE STAFF AT ALL TIMES DURING THE CONSTRUCTION OF THE PROJECT. 2. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM DIRT AND DEBRIS. SURFACES SHALL BE CLEANED OF GREASE, PAINT. OR OTHER MATERIALS NOT SPECIFIED IN THE CONSTRUCTION DOCUMENTS. 3. THE CONTRACTOR IS TO PROVIDE PROTECTION FOR ADJOINING PROPERTIES FROM PHYSICAL HARM, NOISE, DUST. DIRT. AND FIRE AS REOUIRED BY THE GOVERNING AGENCIES. THE CONTRACTOR IS RESPONSIBLE FOR REPAIR OF ANY DAMAGE. 4. THE CONTRACTOR IS RESPONSIBLE FOR THE SECURITY OF THE PROJECT SITE AREA 5. WHERE WORK REQUIRES OPEN HAZARDS TO SITE STAFF, THE HAZARD SHALL BE TEMPORARILY MITIGATED TO OSHA STANDARD UNTIL THE HAZARD IS CLOSED. 6. SEE STRUCTURAL NOTES. UTILITY REQUIREMENTS: 1. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH UTILITY AGENCIES PRIOR TO WORK WITH UTIUTIES. 2. CONTRACTOR TO LOCATE ALL UTILITIES PRIOR TO WORK. 3. CONTRACTOR TO PROTECT, REPLACE AND/OR REROUTE ANY EXISTING UTIUTIES ENCOUNTERED DURING THE COURSE OF WORK. SPECIAL CONSIDERATIONS FOR WEATHERPROOFING: 1. ALL PENETRATIONS TO EXISTING STRUCTURES MUST BE SEALED WITH APPROVED WEATHERPROOFING. IF WEATHERPROOFING IS OMITTED. CONTACT THE PROJECT TEAM FOR CLARIFICATION OR PROVIDE A WEATHERPROOFING PROPOSAL FOR APPROVAL. 2. CONTRACTOR SHALL COORDINATE WITH OWNER AND THE EXISTING ROOFING CONTRACTOR OF RECORD FOR ANY AUGMENTATION TO THE ROOF MEMBRANE, AND HAVING THE WORK GUARANTEED UNDER ME ROOFING CONTRACTORS EXISTING WARRANTY. WORK REQUIREMENT. 1. ALL WORK MUST BE PERFORMED DURING THE OWNERS PREFERRED HOURS. 2. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES. SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 3. ALL WORK PERFORMED ON THE PROJECT SHALL 8E IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. SEE STRUCTURAL NOTES. 4. IF INSPECTION OF WORK IS REQUIRED. THE CONTRACTOR SHALL NOTIFY THE INSPECTION ENTITY 24 HOURS IN ADVANCE OF THE WORK TO BE PERFORMED. 5. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH UTIUTY AGENCIES PRIOR TO WORK WITH UTILITIES. REFERENCE UTILITIES SECTION. 6. THE CONTRACTOR SHALL COORDINATE ON -SITE STORAGE WITH OWNER IN ADVANCE OF WORK. PERMITS MAY BE REQUIRED FOR STORAGE ON PUBUC RIGHT OF WAY. 7. ALL NEW CONSTRUCTION SHALL MATCH EXISTING CONSTRUCTION IN FORM, TEXTURE. FINISH, AND IN MATERIALS EXCEPT AS NOTED IN THE CONSTRUCTION DOCUMENTS. 8. THE CONTRACTOR SHALL MAKE EVERY EFFORT TO PROTECT EXISTING WORK FROM OAMAGE DURING THE COURSE OF WORK FOR THIS PROJECT. 9. THE CONTRACTOR SHALL PROVIDE WORK WHICH IS LEVEL, PLUMB, AND WITHIN TOLERANCES SPECIFIED BY CODES AND STANDARDS INCLUDED IN THE STRUCTURAL NOTES. 10. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURERS SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 11. ANY SUBSTITUTIONS OF MATERIALS MUST BE APPROVED BY THE PROJECT TEAM IN WRITING. 12. THE CONTRACTOR SHALL SUPPLY ALL MATERIALS INCIDENTAL TO THE WORK DESCRIBED BY THE CONTRACT DOCUMENTS. 13. THE CONTRACTOR MUST RESTORE ALL PORTIONS OF THE PROJECT SITE TO ITS PRE -WORK CONDITION. WHERE THE WORK PERFORMED DOES NOT ALLOW FOR PRE -WORK RESTORATION, WORK AREAS MUST BE REPAIRED OR REPLACED TO MATCH EXISTING FINISH AND SITE GRADING. 14. THE CONTRACTOR IS RESPONSIBLE FOR ALL DISPOSAL OF DEBRIS AND ITEMS WHICH ARE SPECIFIED TO BE REMOVED IN THE COURSE OF WORK. CAST -IN PLACE CONCRETE: 1. ALL CONCRETE DESIGN DESCRIBED BY THIS SET OF DRAWINGS IS BASED ON ACI 318 2. ALL STRUCTURAL CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 4,000 PSI. UNLESS SPECIFIED OTHERWISE. 3. EACH CONCRETE MIX DESIGN SHALL HAVE A CYUNDER TEST HISTORY OF 60 DAYS MINIMUM, TESTED IN ACCORDANCE WITH ASTM C39, TESTED BY AN ACI CERTIFIED STRENGTH TESTING TECHNICIAN. AND THE STRENGTH STATISTICALLY DETERMINED IN ACCORDANCE WITH AO 318. EACH MIX DESIGN USED ON SITE SHALL BE SUBMITTED T0, AND RECEIVED BY THE PROJECT TEAM BEFORE THE CONCRETE IS PLACED ON SITE. 4. RAW MATERIALS, MANUFACTURE. AND DELIVERY TO THE FORMWORK SHALL BE IN ACCORDANCE WITH ASTM C94 AND ACI 318. 5. EMBEDDED ITEMS ARE TO BE SECURELY FASTENED SO THAT THEY DO NOT MOVE DURING PLACEMENT OF THE CONCRETE. REFERENCE THE REINFORCING STEEL SECTION. 6. TWO CYLINDERS SHALL BE TAKEN FOR EACH LOAD DELIVERED TO THE FORMWORK. SAMPLES ARE TO BE TAKEN FROM THE CONCRETE AS IT IS PLACED IN THE FORMWORK IN ACCORDANCE WITH ASTM C172. CYLINDERS ARE TESTED PER ASTM C39 AND TESTED BY AN AO CERTIFIED CSTT. CONCRETE SAMPLES ARE TO BE TESTED FOR AIR CONTENT AND WATER CEMENT RATIO. ALL TEST RESULTS ARE SUBMITTED TO THE PROJECT TEAM WITHIN ONE MONTH OF PLACING THE CONCRETE ON SITE. 7. WHEN AMBIENT TEMPERATURES FALL BELOW 55 DEGREES FAHRENHEIT. THE CONTRACTOR SHALL FOLLOW GUIDEUNES DESCRIBED IN ACI 306. WHEN AMBIENT TEMPERATURES RISE ABOVE 90 DEGREES FAHRENHEIT, THE CONTRACTOR SHALL FOLLOW GUIDEUNES DESCRIBED IN AG 305. THE CONCRETE SHALL BE PROTECTED FROM FREEZING OR FROM EXCESSIVE HEAT WITH TENTS OR BLANKETS TO PROVIDE FOR HEAT OR MOISTURE LOSS. 8. ALL CONCRETE SHALL BE PLACED AS CLOSE TO PRACTICAL TO THE FINAL DESTINATION IN THE FORM. CONCRETE SHALL NOT BE PLACE FROM A HEIGHT GREATER THAN 6 FEET FROM THE POINT OF DISCHARGE. 9. VIBRATION SHALL BE USED TO CONSOUDATE CONVENTIONAL CONCRETE. EXTERNAL STINGER VIBRATORS SHALL BE INSERTED VERTICALLY INTO FORMS EVERY 36 INCHES MAXIMUM AND FOR EACH UFT. STINGER VIBRATORS SHALL BE INSERTED TO A VERTICAL DEPTH OF 12 INCHES INTO PREVIOUS LIFTS TO ENSURE CONSOUDATION. FOLLOW GUIDELINES USED IN ACI 309R. 10. REPAIRS FOR MINOR DEFECTS MAY BE ADMINISTERED BY AN EXPERIENCED CRAFTSMAN WITHOUT AN APPROVED PROCEDURE. A MINOR DEFECT INCLUDES BUG HOLES, HONEYCOMBING, CHIPS, AND SPALLS THAT DO NOT EXCEED II INCH OF DEPTH INTO THE FACE OF THE CONCRETE. MAJOR REPAIRS EXTENDING BEYOND Yt INCH OF DEPTH AND UP TO THE REINFORCING MAY BE REPAIRED WITH AN APPROVED REPAIR PROCEDURE. REPAIR PROCEDURES MAY BE SUBMITTED TO THE PROJECT TEAM FOR APPROVAL IN ADVANCE OF FIELD WORK. DAMAGE EXTENDING BEYOND STEEL REINFORCING REQUIRES A RETROFIT DESIGN OR IS REJECTED. 11. SEE ARCHITECTURAL NOTES FOR CONCRETE FINISH REQUIREMENTS EXISTING STRUCTURES: 1. THE EXISTING FRAMING IS REPRODUCED FROM THE LATEST INFORMATION PROVIDED. SOME FRAMING AND MATERIALS ENCOUNTERED AT THE TIME OF CONSTRUCTION MAY VARY FROM THAT SHOWN IN THE PLANS. IF THE PUN CONDITION VARIES FROM THE AS -BUILT CONDITION, THE CONTRACTOR SHOULD CONSULT THE PROJECT TEAM FOR A REVISED DETAIL OR DIRECTION TO PROCEED. ABBREVIATIONS: A/C ACL AMSL APPROX AWC BCW BLDG B1K CLR COAX CONC CONST CONT DIA DWG EA ELEV ELEC E0 EOUIP EXT FIN FLUOR FLR FT FRP GA CALV GC GPS GRND HORZ HR HT HVAC D N NFO NSUL NT BC LBS LMU LTE AIR CONDITIONING ABOVE GROUND LEVEL ABOVE MEAN SEA LEVEL APPROXIMATELY AMERICAN WIRE CAGE BARE COPPER WIRE BUILDING BLOCKING CLEAR COAXIAL CABLE CONCRETE CONSTRUCTION CONTINUOUS DIAMETER DRAWING EACH ELEVATION ELECTRICAL EQUAL EQUIPMENT EXTERIOR FINISH FLUORESCENT FLOOR FOOT FIBER -REINFORCED POLYMER GAUGE GALVANIZED GENERAL CONTRACTOR GLOBAL POSITIONING SYSTEM GROUND HORIZONTAL HOUR HEIGHT HEATING VENTILATION AIR CONDITIONING NSIDE DIAMETER NCH NFORMATION NSULATION NTERIOR NTERNATIONAL BUILDING CODE POUNDS LOCATION MEASUREMENT UNIT LONG TERM EVOLUTION MAX MECH MIL MFR MCR MIN MISC NA NIC NTS MAXIMUM MECHANICAL METAL MANUFACTURE MANAGER MINIMUM MISCELLANEOUS NOT APPLICABLE NOT IN CONTRACT NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER PLYWD PLYWOOD PRDJ PROJECT PROP PROPERTY PT PRESSURE TREATED REO RF RM RO RRH RRU SMT SIM SPEC SF SS STL STRUCT STD SUSP THRU TNA TNNC TYP REQUIRED RADIO FREQUENCY ROOM ROUGH OPENING REMOTE RADIO HEAD REMOTE RADIO UNIT SHEET SIMILAR SPECIFICATION SQUARE FOOT STAINLESS STEEL STEEL STRUCTURAL STANDARD SUSPENDED THROUGH TOWER MOUNTED AMPLIFIER TINNED TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD W/ W/O WP WITH WITHOUT WATER PROOF CONCRETE SLABS ON GRADE: 1. SLAB -ON -GRADE CONSTRUCTION SHALL BE SUPPORTED ON A 6 INCH LAYER OF CLEAN 3/4 INCH MINUS SUBGRADE COMPACTED TO A DENSITY OF NO LESS THAN 952 OF THE MODIFIED PROCTOR MAXIMUM ORY DENSITY (ASTM D-1557). SUBCRADE SHALL BE SUPPORTED ON UNDISTURBED NATIVE SOIL OR PROPERLY PLACED AND COMPACTED STRUCTURAL FILL 2. INTERIOR SLABS -ON -GRADE SHALL BE CAST OVER A 4 MIL VAPOR BARRIER. 3. PROVIDE CONTROL JOINTS IN ALL SLABS ON GRADE. JOINTS ARE TO BE INSTALLED AT 14 TO 16 FEET ON CENTER EACH WAY MAXIMUM UNLESS SHOWN OTHERWISE ON THE DRAWINGS. ALL SAW CUT JOINTS IN CONCRETE SLABS ARE TO BE MADE WITH AN EARLY CUT SAW AS SOON AS POSSIBLE AFTER POURING BUT NO LATER THAN ONE HOUR AFTER FINISHING. 4. PROVIDE ISOLATION JOINTS AROUND ALL COLUMNS/SPREAD FOOTINGS. JOINTS SHALL BE FORMED BY INSERTING PREFORMED JOINT FILLER FOR THE RILL DEPTH OF THE SLAB. 5. PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH DUE TO COLO OR HOT WEATHER IN ACCORDANCE WITH ACI 305 AND 306. CONTRACTOR SHALL TAKE SPECIAL CURING PRECAUTIONS TO MINIMIZE SHRINKAGE CRACKING OF CONCRETE SLABS. 6. THE CONTRACTOR SHALL TAKE CARE THAT HEAVY EQUIPMENT AND AREAS USED FOR STAGING 00 NOT AND DAMAGE SLABS ON GRADE. DAMAGED SLABS ON SHALL BE REPAIRED OR REPLACED AT NO ADDITIONAL EXPENSE TO THE OWNER. 7. CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 2,500 PSI. UNLESS SPECIFIED OTHERWISE. CONCRETE OR MASONRY ANCHORAGE: 1. EXPANSION BOLTS INTO CONCRETE SHALL BE 'KWIK BOLT TZ' AS MANUFACTURED BY THE HILTI CORP., INSTALLED IN STRICT ACCORDANCE WITH ICC-ES REPORT ESR-1917. SPECIAL INSPECTION IS REQUIRED. EXPANSION ANCHORS EXPOSED TO WEATHER SHALL BE STAINLESS STEEL. REINFORCING STEEL: 1. ALL DETAIUNG, FABRICATION, AND PLACEMENT OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ME ACI MANUAL OF CONCRETE PRACTICE. 2. REINFORCING BARS SHALL BE DEFORMED AND CONFORM TO ASTM A615 OR A706, GRADE 60. REINFORCING TIE WIRE MAY BE GRADE 40. 3. REINFORCING STEEL SPLICES SHALL BE 40 BAR DIAMETERS OR TWO TRANSVERSE WIRE SPACINGS FOR WIRE MATS. 4. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE IN ACCORDANCE WITH ACI 318. 5. NO.5 OR LARGER REINFORCING BARS SHALL NOT BE RE -BENT WITHOUT APPROVAL BY THE STRUCTURAL ENGINEER. 6. WELDING OF REBAR IS NOT ALLOWED WITHIN THE MIDDLE THIRD OF THE BAR LENGTH. WELDING OF REBAR IS CONDUCTED IN ACCORDANCE WITH AWS D1.4. USE ONLY ASIA A706 REINFORCING. 7. WIRE REINFORCING CONFORMS TO ASTM A82 OR A185. ITI I P I LEGEND: SUBJECT BOUNDARY LINE - - - - - - - - - RIGHT-OF-WAY CENTERLINE RIGHT-OF-WAY LINE ADJACENT BOUNDARY LINE SECTIONAL BREAKDOWN UNE O- OOt ODAx CDAx COAX CABLE UNE - M FIBER OPTIC CABLE LINE OF. OHv OVERHEAD POWER UNE --- u0v----- ucv-- u0P•--' BURIED POWER LINE - DAs - CAS - 0As - BURIED GAS LINE 041 oar OVERHEAD TELEPHONE LINE - uc1 --- u0.1 --- uu1 BURIED TELEPHONE UNE - w -w -w -w - BURIED WATER LINE - ss ss ss - BURIED SANITARY SEWER - SD SD SD- BURIED STORM DRAIN DITCH LINE/FLOW LINE VEGETATION UNE -x-x-x-x-x-CHAIN LINK FENCE O O Q WOOD FENCE -•-•-■-•-■-•-■-x- BARBED WIRE/WIRE FENCE O TRANSFORMER E:( LICHT STANDARD POWER VAULT ▪ UTILITY BOX AY UTILITY POLE E- POLE GUY WIRE o GAS VALVE ® GAS METER TELEPHONE VAULT O TELEPHONE -RISER 0 v4Z7 A • FIRE HYDRANT D4 GATE VALVE IB WATER METER Q, FIRE STAND PIPE ❑ CATCH BASIN, TYPE I ® CATCH BASIN, TYPE II a SIGN o BOLLARD MAIL BOX 734. 21 SPOT ELEVATION GRID REFERENCE DETAIL REFERENCE ELEVATION REFERENCE SECTION REFERENCE REVISION DIG ALERT RECEIVED SEP 27 2018 Community Development Know what's below. CALL before you dig. CALL AT LEAST TWO WORKING DAYS BEFORE YOU DIG i Giotel >Integrity DeliveredTM 1 • :.IasTec Network Solutions REDS: V 2.0. DATED: 02/01/201S WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUKWILA, WA 9816E KING COUNTY 08- 30- 2018 \ EXPIRES 01-09-2019 J REVISIONS REV. DATE DESCRIPTION BY A 03/n/11 6511E0 FOR IOx CO RML1 TR 0 01/30/10 Is5UE0 FOR 100X COMSTRUC11O14 IL. TITLE GENERAL NOTES -4 [SHEET G1 J 8. CONCRETE COVER FOR REINFORCING STEEL CONFORMS TO ACI 318. (GLOTEL PROJECT 8: J5568D 0 0 0 U 0 0 m A 0 O U 0 0 24'x36' SCALE: 1' = 20'-0 �11-x17' SCALE: 1" = 40'-0" EXISTING CHAJNUNK FENCE ADJACENT ZONING USE: INDUSTRIAL ZONE: MIC/H TL# 0423049186 EXISTING/WIOPOSFD AT&T ENNA LOCATION SUBJECT ZONING USE: INDUSTRIAL ZONE: MIC/H SCL TRANSMISSION TOWER ROW TLd 0423049130 822.899 S0. FT. (18.89 ACRES) NOTES: 1. VERIFICATION TNAT THE ANTENNA MOUNTS CAN SUPPORT ALL PROPOSED LOADING SHALL BE PERFORMED BY A REGISTERED STRUCTURAL ENGINEER 2. STRUCTURAL ANALYSIS AND DESIGN TO BE PERFORMED PRIOR TO FCO COMPLETION 3. THIS IS NOT A SITE SURVEY. ALL PROPERTY LINES AND BOUNDARIES ARE TAKEN FROM AN EXISTING PARCEL VIEWER AND ARE APPROXIMATE FGALJ)FSCRIPDON: C OF S TRANS LN R/W OVER GL 4 & 5 TCW SE 1/4 LESS ST HWY TCW 250 FT R/W OVER TRACT 55 OF MOORES FIVE -ACRE TRACTS & VAC C FRAIEGER RD LESS ST HWY PARCEL NUMBER(S); 0423049130 ADJACENT ZONING USE: INDUSTRIAL ZONE: MIC/H TL# 0423049189 I `RL PARKING LOT G/1(-6o93 SEP 27 2803 Community Development TRUE NORTH SITE PLAN I 1 Giotel >Integrity DeliveredTM •IselasTec Network Solutions RFDS: V 2.0. DATED: 02/01/2018 WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY 08- 30- 2018 EXPIRES 01-09-2019 J REVISIONS REV. DATE DFSQLPTIOM BY A 03M/1I 1S5Dm FOR 90i C0 WADI TR 0 09/10/1$ ISSUED FOR 10011 CONSTRUCTION RJR I J TITLE SITE PLAN SHEET A-1 GLOTEL PROJECT*. J5568) a J 0 J m VI O U) 0 U 0 0 NOTE: ONLY PROPOSED AT&T mimeos ARE SHOWN IN PLAN NEW FOR CURRY. 1101E: 1. ALL PROPOSED AT&T POLE MOUNTED ANIMAS. EQUIPMENT AND CABLES TO BE PAINTED TO MATCH DUNG UTILITY POLE 24'k36- SCALE: 1/4" = 1'-0- �1'K17- SCALE: 1/8- - 1'-0- 4 3 2 1' Cr EXISTING TRANSMISSION TOWER EXISTING CHAIN-UNX FENCE W/ BARB WIRE EXISTING LANDSCAPING AREA EXISTING CONCRETE CURB (TYP) EXISTING LIGHT POLE 4' ENLARGED SITE PLAN I 1 Giotel >Integrity DeliveredTM •:IasTec Network Solutions RFDS: V 2.0. DATED: 02/01/2018 WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUK W ILA, WA 98168 KING COUNTY EXPIRES 01-09-2019 j REVISIONS REV. DATE DESCRIPTION BY A 01/03/11 *SUM FOR 10; CD ROM. 1R 0 a/X/III ISSUED FOR 100[ CONSIRUCn011 RJR TITLE ENLARGED SITE PLAN [SHEET A2 J CGLOTEL PROJECT #: J5568 J EXISTING ACCESS GATE EXISTING AT&T ICE CANOPY (ABOVE) TO RD&AIN PROPOSED AT&T LTE 700.1900/AWS RRH (1 PER SECTOR. 3 TOTAL) EXISTING AT&T BBU WITH (12) MARATHON BATTERIES CABINET TO REMAIN EXISTING AT&T TE21 POWER CABINET TO REMAIN EXISTING AT&T NOKIA CABINET TO REMAIN PROPOSED AT&T 700164 RRH (1 PER SECTOR. 3 TOTAL) EXISTING AT&T TE40 CABINET TO RDAAM EXISTING AT&T TELCO ENCLOSURE TO REMAIN EXISTING AT&T UMTS CABINET TO REMAIN EXISTING AT&T 100 AMP ELECTRICAL SERVICE PANEL W/ METER & SERVICE UGHT TO REMAIN EXISTING AT&T MICRIN GEN PLUG TO ROMMN EXISTING AT&T 200 AMP ELECTRICAL SERVICE TO REMAIN EXISTING AT&T CPS ANTENNA TO REMAIN EXISTING AT&T TE43 CABINET TO REMAIN EXISTING 6'-0" CHAIN —LINK FENCE W/ BARB WIRE & PRIVACY SLATS PROPOSED AT&T (1) RET,I1AER BSTWITHIN EXISTING PURCELL CABINET EXISTING AT&T LTE 850 RRH (1 PER SECTOR. 3 TOTAL) TO REMAIN EXISTING AT&T LTE WCS RRH (1 PER SECTOR. 3 TOTAL) TO RDWN EXISTING AT&T UMTS DIPLEXER (2 PER SECTOR, 6 TOTAL) TO ROAM PROPOSED AT&T OLMDPLFOER (3 PER O SECTOR 12 T0E1L) EXISTING AT&T DISTRIBUTION UNIT 70 RE MN EXISTING AT&T H—FRAME W/ HOFFMAN BOX 70 REMAIN PROPOSED AT&T (8) 1—S/B" COAX TRUE N0 TI4 EXISTING ACCESS GATE EXISTING AT&T ICE CANOPY (ABOVE) TO REMAIN — EXISTING AT&T LTE 1900 RRH (1 PER SECTOR. 3 TOTAL) TO BE REPLACED EXISTING AT&T BBU WITH (12) MARATHON BATTERIES CABINET TO REMAIN •-- EXISTING AT&T TE21 POWER CABINET TO REMAIN EXISTING AT&T GSM CABINET TO BE ROAMED EXISTING AT&T LTE 700 RRH (1 PER SECTOR, 3 TOTAL) 70 BE REPLACED EXISTING AT&T TE40 CABINET 10 REMAIN EXISTING AT&T TELCO ENCLOSURE TO REMAIN EXISTING AT&T UMTS CABINET TO REMAIN EXISTING AT&T 100 AMP ELECTRICAL SEANCE PANEL W/ METER & SERVICE LIGHT TO REMAIN EXISTING AT&T MICRIN GEN PLUG TO ADMAN EXISTING AT&T 200 AMP ELECTRICAL SERVICE TO REMAIN EXISTING 6'-0" CHAIN —LINK FENCE W/ BARB WIRE & PRIVACY SLATS EXISTING AT&T PURCELL FLX16 CABINET TO REMAIN EXISTING AT&T LTE 850 RRH (1 PER SECTOR. 3 TOTAL) TO REMAIN EXISTING AT&T LTE WCS RRH (1 PER SECTOR, 3 TOTAL) 70 REMAIN EXISTING AT&T GSM DIPLEXER (2 PER SECTOR. 6 TOTAL) TO BE REIKAED EXISTING AT&T LINTS DIPLEXER (2 PER SECTOR. 6 TOTAL) TO RD MN EXISTING AT&T DIPLEXERS (2 PER SECTOR. 6 TOTAL) TO BE REPLACED + / } IBGAT&T DISTRIBUTION UNIT + } 70 ROWN N / EXISTING AT&T H—FRAME W/ EXISTING AT&T CPS / HOFFMAN BOX TO ANTENNA 10 REMAIN% REMAIN \+/ EXISTING AT&T TE43 CABINET TO REMAIN EXISTING (6) AT&T 7/8" COAX RUNS 70 BE REPLACED WAN (8) NEW 1-6/8' COAX RECEIVED SEP 27 2018 Community Development 71F- TRUE IRRTR Giotel >Integrity DeliveredTM • :IasTec Network Solutions RFDS: V 2.0. DATED: 02/01/2018 WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUK W I LA, WA 98168 KING COUNTY EXPIRES 01-09-2019 j REVISIONS NEV. DATE DESCRIPTION 8Y A 091/71/1I IAum FOR 90X CO RCA* TR 0 WWI 45UE0 FOR I OOE cw+SIMucnad 'RJR TITLE EQUIPMENT LAYOUT SHEET A-3 J 24"r36" SCALE: 3/8" a 1'-0" 11117" SCALE: 3/16" 1'-0" 2' 1 0" 2' PROPOSED EQUIPMENT LAYOUT 2 24%36" SCALE: 3/8" = 1'-0" 114a17" SCALE: 3/16" - 1'-0" 2 1' 0 2' EXISTING EQUIPMENT LAYOUT (GLOTEL PROJECT 8: 15568) 00 NOTES ALL PROPOSED AT&T POLE MOUNTED ANTENNAS, ENUPME4T AND CABLES TO BE PAINTED TO MATCH CASTING UTILITY POLE 4 TOP OF SCL TRANSMISSION TOWER 156'-8" AG.L. 4 EXISTING TRANSMISSION UNE 134'-2" A.G.L. 4 EXISTING TRANSMISSION UNE 4 115'-9" A.G.L. EXISTING 12.-0- EXCLUSION AREA (TYP) EXISTING TRANSMISSION UNE 97'-6" A.G.L. RECONFIGUREDAT&T LTE 700, 1900/AWS ANTENNA (1 PER SECTOR, 3 TOTAL) TO REMAIN 4 RAD CE R OF AT&T I `I' EXISTING�lka'i7SL0-ANTENNAS I■I1ii1l l� 82'-0' A.C.L. , EXISTING AT&T LTE WCS/850 ANTENNA (1 PER SECTOR. 3 '. TOTAL) 10 RE)LABN -- PROPOSED AT&T LTE 700 ANTEINL (1 PER ���� SECTOR, 3 TOTAL) EXISTING AT&T UMTS TMA (1 PER SECTOR. 3 TOTAL) TO REMAIN EXISTING AT&T UMTS 1900/850 ANTENNA (1 PER SECTOR. 3 TOTAL) TO REMAN I ¶ I t EXISTING AT&T TE43 CABINET 10 REMAIN EXISTING AT&T GPS ANTENNA TO ROMAN GRADE O'-0 AGL (18.251 ANISE) 24"x36" SCALE: 3/32- = 1 -0 EXISTING AT&T LTE 700 RRH (1 PER SECTOR, 3 TOTAL) TO PROPOSED AT&T LTE Aft'S RRH (1 PER SECTOR 3 TOTAL) EXISTING AT&T LTE 1900 RRH (1 PER SECTOR, 3 TOTAL) TO MAIN i i i i 11"x17" SCALE: 3/64" 0 1'-0" 8 4 0 EXISTING TRANSMISSION UNE 4) 155.-7" A.G.L. EXISTING TRANSMISSION UNE 4, 135'-3" A.G.L. EXISTING TRANSMISSION UNE 4 116"-10" A.G.L. EXISTING TRANSMISSION LINE 4 98"-6" EXISTING TRANSMISSION TOWER PROPOSED AT&T LTE 700 RRH (1 PER SECTOR 3 TOTAL) EXISTING AT&T ICE CANOPY To Rom EXISTING AT&T UMTS CABINET TO REMAIN PROPOSED AT&T OIPLDE7L ej (2 PEE SECTOR, 6 TOTAL) -EXISTING CHAIN-UNK FENCE EXISTING AT&T PURCELL FLX16 CABINET TO ROMAN EXISTING AT&T DIPLEXER (2 PER SECTOR, 6 TOTAL) TO MOAN 4 TOP OF SCL TRANSMISSION TOWER 156'-8" A.G.L. 4 EXISTING TRANSMISSION LINE 134'-2" A.G.L. 4 EXISTING TRANSMISSION UNE 4 115'-9" AG.L. EXISTING 12'-0" EXCLUSION AREA (TYP)—\\ EXISTING TRANSMISSION UNE I wh, 97.-6" AO.L. EXISTING AT&T LTE 1900/700 ANTENNA (1 PER SECTOR, 3 TOTAL) TO BE RfOOIE101IRED EXISTING AT&T LTE TMA (1 PER SECTOR, 3 TOTAL) TO BE REPLACED RAD CENTER OF AT&T EXISTING ANTENNAS Y 82.-0" AC.L. EXISTING AT&T LTE TMA (1 PER TO BESELACED CTOR, 3 TOTAL) EXISTING AT&T LTE WCS/650 ANTENNA (1 PER SECTOR, 3 TOTAL) TO REMAIN EXISTING AT&T GSM TMA (1 PER SECTOR. 3 TOTAL) TO BE REMOVED EXISTING AT&T GSM 1900/850 ANTENNA (1 PER SECTOR, 3 TOTAL) TO BE REPLACED EXISTING AT&T UMTS TMA (1 PER SECTOR, 3 'TOTAL) 10 REMAIN EXISTING AT&T UMTS 1900/850 ANTENNA (1 PER SECTOR. 3 TOTAL) TD MINN EXISTING AT&T TEAS CABINET TO REMAIN EXISTING AT&T GPS ANTENNA TO REMAIN GRADE 0 -0" AGL (18.251 ANISE) EXISTING AT&T LTE 700 RRH (1 PER SECTOR, 3 TOTAL) TO BE REPLACED EXISTING AT&T LTE 1900 RRH (1 PER SECTOR, 3 TOTAL) TO BE 11:PACED 24"x36" SCALE: 3/32- - 1 -0 11"x17" SCALE: 3/64" = 1 -0 8 40 8' ELM" All SA II ;' i11'1•!i1 EXISTING TRANSMISSION LINE 4) 155.-7" A.G.L. EXISTING TRANSMISSION LINE 4 135'-3" A.G.L. EXISTING TRANSMISSION LINE u 116`-10" A.G.L. EXISTING TRANSMISSION LINE 4 98.-6" A.C.L. EXISTING TRANSMISSION TOWER EXISTING AT&T LTE 850 RRH (1 PER SECTOR. 3 TOTAL) TO REMAIN EXISTING AT&T LTE WCS RRH (1 PER SECTOR. 3 TOTAL) TO RENNIN EXISTING AT&T ICE CANOPY TO REMAIN EXISTING AT&T UMTS CABINET 10 ROLNN EXISTING AT&T GSM DIPLEXER (2 PER SECTOR, 6 TOTAL) TO BE REMOVED EXISTING CHAIN-UNK FENCE EXISTING AT&T PURCELL FLX16 CABINET TO ROOM EXISTING AT&T LTE DIPLEXER (2 PER SECTOR. 6 TOTAL) TO BE REPLACED R=CE1VED SEP 27 2018 Community mn# Devel Giotel >Integrity DeliveredTM •:eIasTec Network Solutions RFDS: V 2.0. DATED: 02/01/2018 WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY EXPIRES 01-09-2019 j REVISIONS REV. DATE DESCRIPTION BY A 00/D/10 ISSUED FOR 902 CO REV01 TR 0 01/10/10 ISSUED RUR 100S CORSIRUCTOM WM C TITLE EXISTING & PROPOSED SOUTHEAST ELEVATION J SHEET A-4 CGLOTEL PROJECT 8: 15568 J 8' PROPOSED SOUTHEAST ELEVATION 2 EXISTING SOUTHEAST ELEVATION 1J 0 O 0 D z 0 NOT USED 24-X36" SCALE: N.Y.S. 11 "X 17' SCALE. NS S NOT USED 24-X36" SCALE: N.T.S. 11-4,17' SCALE' NS S PLAN VIEW MANUFACTURER: COMMSCOPE MODEL- TMAT192123868-31 El 4ROOP33 WEIGHT W/MOUNTING HARDWARE: 22.9 LBS DIMENSIONS: 9.4" X 11.1" X 3.8" FRONT VIEW SIDE VIEW TMA SPECIFICATIONS( 24"1 ,1 SCALE:CA1 1 /2= - 1"-0 LL'Y.17' SCALE' 1 /2 a 0' NOTES 1. INSERT SCISSOR BRACKETS BETWEEN THE UPPER ANTENNA MOUNTING BRACKET AND THE UPPER POLE ADAPTER BRACKET. SECURE USING 1/2 INCH HARDWARE PROVIDED. 2. TO SET THE DEGREE OF DOWNTILT, ALIGN THE DESIRED HOLES ON THE SCISSOR BRACKETS AND SECURE USING 5/16 INCH HARDWARE PROVIDED. 3. THE NUMBER OF CONNECTORS WILL VARY BASED ON ANTENNA TYPE. PARTS ITEM CITY DESCRIPTION (1) 1 ADAPTOR, POLE, LOWER 1 BRACKET, DOWNTILT, POLE 1 BRACKET, DOWNTILT, ANTENNA 4 4 1/2 X 1 HEX HEAD BOLT 4 1/2 SPLIT WASHER 6 2 5/16 X 1 HEX HEAD BOLT 2 5/16 SPLIT WASHER ANTENNA MOUNTING( 24"X36" SCALE: N.T.S. L1_'X17' SCALE. NJ " 15.4" MANUFACTURER: NOKIA MODEL: AIRSCALE DUAL RRH 4T4R B25/66 320W AHF19 MOUNTED WEIGHT: 88.2 LBS DIMENSIONS: 28.7. X 15.4" X 9.4' 9.4- O AWS RRH UNIT 24'X36" SCALE: 1" - 1"-0� 111'M SCALE. 1L7" = 1'-n" MANUFACTURER: NOKIA MODEL: NRSCALE DUAL RRH 4T4R B12/14 320W AHLBA MOUNTED WEIGHT: 101.4 LBS DIMENSIONS: 28.7- X 15.4. X 9.4' 9.4" O PLAN VIEW MANUFACTURER: KMW MODEL: TBC0038F1V94-2 WEIGHT: 13.2 LBS DIMENSIONS: 7.48' X 6.3- X 5.1' SIGNS AND PLACEMENT: 1. LOW LEVEL BLUE NOTICE SKINS - PLACE AT SITE ENTRY / ACCESS POINTS ONLY. - ROOFTOPS: PLACE SIGNS ON THE INSIDE OF ROOF HATCH; PLACE ON ACCESS DOOR UNLESS DOOR IS USED BY GENERAL PUBLIC OR BUILDING TENANTS ON A REGULAR BASIS FOR ACCESS - IN THESE CASES CONSULT CONSTRUCTION MANAGER. - WATER TANKS: PLACE SIGNS ON COMPOUND GATE. - NETWORK CARRIER OWNED SITES: PLACE ONE SIGN ON COMPOUND LATE; ALL SIGNS SHALL BE SECURED WITH EITHER STAINLESS STEEL ZIP TIES OR STAINLESS TECH SCREWS. 2. CONSTRUCTION COORDINATOR PARTICIPATION IN SIGN LOCATION: NETWORK CARRIER CONSTRUCTION MANAGER SHALL MEET WITH ALL CONSTRUCTION COORDINATOR'S TO OUTLINE CRITERIA FOR SIGN PLACEMENT. EMPHASIS SHALL BE PLACED ON "CHALLENGING' SITES, WHERE THE NETWORK CARRIER CONSTRUCTION MANAGERS SHALL GIVE CONSTRUCTION COORDINATOR'S AS MUCH GUIDANCE ON EACH SPECIFIC SITUATION AS POSSIBLE, HOWEVER, CONSTRUCTION COORDINATOR'S SHALL BE ENCOURAGED TO PARTNER WITH NETWORK CARRIER CONSTRUCTION MANAGER IN DECIDING PLACEMENT PERTAINING TO CHALLENGING SITES. A SITE VISIT MAY BE REQUIRED TO FULFILL REQUIREMENTS. CONSTRUCTION COORDINATOR SHALL IDENTIFY ALL SIGN LOCATIONS AT THE A&E WALK. PLEASE SEE SIGN DETAIL AND SIZE. 3. SIGN DISBURSEMENT FROM WAREHOUSE: SIGN INVENTORY SHALL BE ACCESSIBLE AT NETWORK CARRIER WAREHOUSE TO BE DISBURSED AS PART OF THE GENERAL CONTRACTOR BOAR AS CALLED OUT IN A&E DRAWINGS FOR EACH SITE. DIPLEXER SPECIFICATIONS( 24"X36" SCALE- 1 1/2" = 1'-0' 11'X17\ " SCAT F' 1/4' : 1'-n 8" NOTICE (y) .e"y..•a.. Irw.e• RF SIGNAGE 4"X36" SCALE: N.T. 11"X17" SCAIF. NTS 700 RRH UNIT( 24-X36 SCALE: 1" = 1'-0 SC41 F' 1L2" = 1'-0" �� MANUFACTURER: COMMSCOPE MODEL: SBNHH-1D65C WEIGHT: 49.6 LBS DIMENSIONS: 96.0' X 11.9" X 7.1' FREQUENCY: REFER TO RF DATA SHEET IQP_ RECEIVED SEP 27 201B Community CC'.e cp `'TPal 11.9' MECHANICAL DOWNTILT BRACKET FRONT RF CONNECTOR, TYP 7.1' SIDE ANTENNA SPECIFICATIONS 24 X36" SCALE: 3/4" = 1.-0'I 11-X17- SCNF• 1/A' = 1'-0' Giotel >Integrity DeliveredTM :IasTec Network Solutions RFDS: V 2.0. DATED: 02/01/2018 WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUK W ILA, WA 98168 KING COUNTY 08-30-2018 EXPIRES 01-09-2019 J REVISIONS REV. DATE DESCRIPMN BY A W/03/11 ISSUED FOR 1011 CD REVIEW IR 0 01/00/11 ISSI(0 FOR 100% CONSfRUC110N FIR TITLE RF DETAILS SHEET A-5 (GLOTEL PROJECT k: 15568) 0 0 0 8 0 0 0 0 z 0 PROPOSED AT&T LIE TMA O(2 PER SECTOR. 6 TOUL)- RECOEF1GU1ED EXISTING AT&T LTE 700, 1900/AWS ANTENNA (1 PER SECTOR, 3 TOTAL) TO REMAIN EXISTING TRANSMISSION TOWER OTE: • �m USE COAT( LENGTHS FOR CUT tE DNS: EEME1CCOfAr • COFBFM TINT GENERAL CONTRACTOR IS USNG LATEST VERSION OF RFDS. RPSD AENA c\IUA nN AD SHDLES.AE: 0/121 ETR A ArnAITR ��� VNOODW/LEUBR Cx • O DP(F OOX LNIRUN8 10102AHEN 7225 () 71-8P1-0/' 10UT5LE 70 102OMCPBH-05OE - - - -E p5 102OMCPBH-051FD0003-/' 101I5LE 10/NS 102OMCPBH-052MT9136- 4 1581' 2LE 70 3_1RD3 ETR B ADTAETR NMEOVNOOEMUBR C1L • CAFEENMEF OOX LNTRLE 110AV102OMCPBH-D52MT9136- 4 1581' 2LE 70 3_1RO3 T08' 8' 1 CMSOE SNH16C NN lI8' 8' 1 CMSOE SNH16C () KTR0000 2 1581' -LE 60 1 IS 10302AHEN 7225 () 11-8P1-0/" 10UT5SCOaUA1 WI VIO0FEUBRF N UBR O aX • lC H DPDILE 1052OMCPBH-052MT9t36- 4 1581' 2LE 70 3_1RO3 T052OMCPBH-05OE - - - - - LE '52OMCPBH-051FD0003-/' 101E 60 1 115 1052AHEN 7225 () T1-8P1-0/" 10UI5 EXISTING AT&T UMTS 1900/850 ANTENNA /` (1 PER SECTOR, 3 TOTAL) TO REMAIN1hX, ♦.� ii N EXISTING AT&T TMA (1 PER SECTOR, 3 TOTAL) TO REIAAN EXISTING AT&T UMTS LTE WCS/850 ANTENNA (1 PER SECTOR. 3 TOTAL) 1O REMAN PROPOSED AT&T LIE 700 ANTENNA (1 PER SECTOR 3 TODU SECTOR oA2. EXISTING AT&T LTE 1900/700 ANTENNA (1 PER SECTOR, 3 TOTAL) TO REMAIN .Q111 PROPOSED I T ORDER�'�(1 PER SECTOR, 3 TCf 4` 4\1\liJ• rr, EXISTING AT&T LTE WCS/850ANTENNA (1 PER SECTOR, 3TOTAL) TO ROMIN S�nT 4 v PROPO® AT&T LTE(1 PER SELTOR. 3 TOUL)RE130 170URFD EXISTING AT&T LTE 700, 1900/AWS ANTENNA (1 PER SECTOR, 3 TOTAL) 70 REI MN PROPOSED AT&T LIE 700 ANTENNA (1 PER SECTOR. 3 TOTAL) 0© EXISTING AT&T LTE WCS/850 ANTENNA (1 PER SECTOR, 3 TOTAL) TO ROOM EXISTING AT&T TMA (1 PER SECTOR. 3 TOTAL) TO ROOM EXISTING AT&T UMTS 1900/850 ANTENNA (1 PER SECTOR, 3 TOTAL) TO REMMI GAO P. EXISTING AT&T UMTS TMA (1 PER SECTOR. 3 TOTAL) TO RENN EXISTING AT&T UMTS 1900/850 ANTENNA (1 PER SECTOR, 3 TOTAL) TO IENAN PROPOSED AT&T LIE 700 MEDINA (1 PER SECTOR 3 TOTAL) 4111141111 'We WY TINE KORTH IXISI INC, \NIL\NA CONIIGLIRAIION AND SCHEDULE RFD6: V 2.0 GATED: 02/01/201a SECTOR A AZIMUTH RAD COMM NUMMI CF VENDOR MODEL IWI/FILIER NUMBER OF 00AX OCIAX • �A ® OIPtcNUMBER CF RRH WIS 1900 140' 82' 1 KATHREIN 742-265 (1) TT 19-OBBP111-001 2 7/8" 110' 2 - UNITS 850 C91 1900 140' 82' 1 KATHREIN 742-265 (1) TT19-088P111-001 2 7/8 110' 2 - GSM 850 LIE 1105• 170' 82' 1 COMMSCOPE SBNHH-1065C (1) TMA2117FOOV1-1 2 1-5/8" 110' 1 1 LTE 650 1 LIE 1900 170' 82' 1 COMMSCOPE SBNHH-1065C (1) KFTDR00000030 2 1-5/5" 110' 1 1 LTE 700 (1) TMA2117FOOV1-1 1 SECTOR B AZMRH RAD CENTER NUMBER OF ANTENWIS VENDOR MODEL 7W NUMBER OF COAX 03AX • COAX LENGTH DIPLOID NUMBER OF RRH 00 280' 82' 1 COMMSCOPE SBNHH-1065C (1) TMA2117FOOV1-1 2 1-5/8" 110' 1 1 ` 0511 1100 330' 82' 1 KATHREIN 742-265 (1) TT19-088P111-001 2 7/8" 110' 2 - GSM 850 LIE TICS 280' 82' 1 COMMSCOPE SBNHH-1065C (1) KFTDR00000030 2 1-5/8" 110' 1 1 LIE 650 (1) TMA2117FOOVI-1 I UIIS 1900 330' 82' 1 KATHREIN 742-265 (1) TT19-08BP111-001 2 7/8" 110' 2 - UMTS 850 SECTOR C A01EU111 PAD CErtER MAIM ,°F VENDOR MODEL TMA NNUMMI COAX COAX • �A DIMMED NUMB OF LTE 1900 45' 82' 1 COMMSCOPE SBNHH-1065C (1) TMA2117FOOVI-1 2 1-5/8" 110' 1 I LTE 700 1 GM/ 1600 50' 82' 1 KATHREIN 742-265 (1) TT19-080P111-001 2 7/8' 110' 2 - GSM 650 LTE ITCS 45' B2' 1 COMMSCOPE SBNHH-1D65C (1) KROR00000030 2 1-5/8' 110' 1 1 LIE 650 (1) TMA2117FOOVI-1 1 UMTS 1900 50 82' 1 KATHREIN 742-265 (1) 1T19-088P111-001 2 7/8" 110' 2 - UMTS 850 EXISTING AT&T UMTS 1900/850 ANTENNA (1 PER SECTOR, 3 TOTAL) TO REWIN EXISTING AT&T UMTS TMA (1 PER SECTOR. 3 TOTAL) TO ROAN EXISTING AT&T LTE TMA (1 PER SECTOR, 3 TOTAL) TO BE REPLACED EXISTING AT&T LTE WCS/850 ANTENNA (1 PER SECTOR, 3 TOTAL) 70 REINN EXISTING AT&T GSM 1900/850 ANTENNA (1 PER SECTOR, 3 TOTAL) 10 BE REPLACED EXISTING AT&T GSM TMA (1 PER SECTOR, 3 TOTAL) TO BE REMOVED s SECTOR U0,O u. EXISTING AT&T LTE 1900/700 ANTENNA (1 PER SECTOR, 3 TOTAL) TO BE RECONFIGURED / 1 / EXISTING AT&T LTE TMA (1 PER SECTOR, 3 TOTAL) TO BE BEHOVED EXISTING AT&T LTE TMA (1 PER SECTOR. 3 TOTAL) TO BE REPLACED EXISTING AT&T LTE WCS/850 ANTENNA (1 PER SECTOR. 3 TOTAL) TO RONNN EXISTING AT&T LTE TMA (1 PER SECTOR, 3 TOTAL) TO BE REPLACED EXISTING AT&T LTE 1900/700 ANTENNA (1 PER SECTOR. 3 TOTAL) 10 BE RECONFIGURED EXISTING TRANSMISSION TOWER EXISTING AT&T LTE TMA (1 PER SECTOR. 3 TOTAL) TO BE REPLACED EXISTING AT&T LTE 1900/700 ANTENNA (1 PER SECTOR, 3 TOTAL) TO BE RECONFIGURED EXISTING AT&T GSM TMA (1 PER SECTOR, 3 TOTAL) TO BE ROPED EXISTING AT&T GSM 1900/650 ANTENNA (1 PER SECTOR, 3 TOTAL) TO BE REPLACED EXISTING AT&T LTE TMA (1 PER SECTOR. 3 TOTAL) TO BE REPLACED EXISTING AT&T LTE WCS/850 ANTENNA (1 PER SECTOR, 3 TOTAL) TO REMAIN EXISTING AT&T UMTS TMA (1 PER SECTOR, 3 TOTAL) TO ROAM EXISTING AT&T UMTS 1900/850 ANTENNA (1 PER SECTOR, 3 TOTAL) TO ROOM EXISTING AT&T UMTS TMA (1 PER SECTOR, 3 TOTAL) TO ROAN EXISTING AT&T UMTS 1900/850 ANTENNA (1 PER SECTOR, 3 TOTAL) TO ROOM EXISTING AT&T GSM TMA (1 PER SECTOR. 3 TOTAL) TO BE REMOVED EXISTING AT&T GSM 1900/850 ANTENNA (I PER SECTOR, 3 TOTAL) TO BE REPLACED Li 7-009,3 RECEIVED SEP 27 2018 Community Development Giotel >Integrity DeliveredTM • :IasTec Network Solutions RFDS: V 2.0. DATED: 02/01/2018 WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUKWILA, WA98168 KING COUNTY EXPIRES 01-09-2019 J REVISIONS REV. DATE MORON 6T A 00/2T/14 OSU, FOR YOR CO REVIEW m 0 •/30/14 IAUND TOR 100R CONSIRUCTXIK MF C EXISTINGG&PROPOSED ANTENNA CONFIGURATIONS SHEET RF-1 24-A36" SCALE: 3/16' - 1'-0" 1 v 17' SCALE: 3/32' - 1'-0" 111111� 4 2 0 PROPOSED ANTENNA CONFIGURATION 24"P36" SCALE: 3/16" = 1'-0 11-A17" SCALE: 3/32" - 1'-0" 42 0 4' EXISTING ANTENNA CONFIGURATION CG LOTEL PROJECT*: 1556) PROHIBITED. IS PROPRIETARY BY NATURE. u u 0 SYMBOL DESCRIPTION ® COPPER GROUND ROD • CADWELD • EXOTHERMIC WELD ® TEST WELL GROUND BAR GROUND WIRE #2 AWG GROUND RING FIELD VERIFY & TIE INTO EXISTING GROUNDING SYSTEM GENET TES: 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METAWC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURER'S PRACTICES FOR GROUNDING REGUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES. 3. ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 4. CONTRACTOR TO VERIFY AND TEST GROUND SOURCE, GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WRNESSEO BY CARRIER, REPRESENTATIVE. 5. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING STJILM, AND RECENE APPROVAL OF DESIGN BY AUTHORIZED CARRIER, REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING STSILM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RINGS. 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. 8. USE PANT SCHEME FOR LOADING GROUNDS ON MGB AS DISCUSSED IN NSTD 119, 33 & 36. GROUND ROD NOTES' 1. ELECTRICAL CONTRACTOR SHALL ORDER GROUND RESISTANCE TESTING ONCE THE GROUND SYSTEM HAS BEEN INSTALLED; A QUALIFIED INDIVIDUAL, UTIUZING THE FALL OF POTENTIAL METHOD, SHOULD PERFORM THE TEST. THE REPORT WILL SHOW THE LOCATION OF THE TEST ANO CONTAIN NO LESS THAN 9 TEST POINTS ALONG THE TESTING UNE, GRAPHED OUT TO SHOW THE PLATEAU. 2. POINT GROUND TEST OR 3 POINT 62% TESTS WILL NOT BE ACCEPTED AS ALTERNATIVES TO THE AFORE MENTIONED GROUND TESTS. TEST SHALL BE PERFORMED WHILE THE COUNTERPOISE IS ISOLATED FROM THE A/C SYSTEM GRIDS AND EXISTING COMMUNICATIONS FACILITY. KEY NOTES: O1 CADWELD (TYP.) SEE SHEET E-2. OANTENNA GROUND BAR TOP OF UTILITY POLE. SEE SHEET E-2 EXISTING GROUND BUS BAR AT BASE OF TOWER. SEE O SHEET E-2 EXISTING GROUND FROM ANTENNA GROUND BUS BAR O TO TOWER GROUND BUS BAR (TYP OF (2) PLACES). SEE SHEET E-2 OA6 AWG GROUND FROM EOUIPMENT TO GROUND BAR. S SEE SHEET E-2. © ANTENNA SECTOR GROUND BAR AT EACH SECTOR SEE SHEET E-2 (TYP OF 2) #2 AWG GROUND FROM SECTOR GROUND BUS BAR ANT(TYPA OFF (2) PLACES)OUND BUS.S TO 0SEE SHEET E-2 O#2 AWG GROUND TO EXISTING HALO RING (V.I.F.) SEE SHEET E-2. 9 B6 AWG GROUND FROM RRH TO TIE INTO EXISTING SECTOR GROUNO BAR (TYP OF 2). SEE SHEET E-2. 10 B6 AWG GROUND FROM OIPLEXER TO TIE INTO EXISTING GROUND BAR (TYP OF 2). SEE SHEET E-2. 11 d6 AWG GROUND FROM TMA TO TIE INTO EXISTING SECTOR GROUND BAR (TYP OF 6). SEE SHEET E-2. #6 AWG GROUND FROM ANTENNA TO TIE INTO EXISTING SECTOR GROUND BAR (TYP OF 2). SEE SHEET E-2. z Z 0 24' 36- SCALE: 3/8" _ ` V11'K17" SCALE: 3/16' / + / + / + \ 4' + \ ++ +/ TBU[ NORTH RECEIVED SEP 27 201B Community Development N -IP— TRUE NORTH 2 0 NOT USED 12 24%36" SCALE: 3/16' = 11"x17' SCALE: 3/32" 1'-0- 4 2 0" 4' ANTENNA GROUNDING SCHEMATIC Giotel >Integrity DeliveredTM • :MIasTec Network Solutions ` RFDS: V 2.0. DATED: 02/01/2018 WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUK W I LA, WA 98168 KING COUNTY EXPIRES 01-09-2019 / REVISIONS REV. DATE CIESCRIPPON or A 00/]]/11 ISSUED FOR 002 CD REVLW TR 0 •/W/l! ISSUED FOR 100R CORSIRUCIION WA TITLE SCHEMATIC GROUNDING PLAN SHEET E-1 l CGLOTEL PROJECT 0 355688 cc 8 O 0 RMATION CO NOT USED I S^ X" SCALE: N.T.S. 11"V 1'X1736SCALE• NTS NOT USED 24'x37" SCALE: N.T.S. 1 11-X17' SCALE: N.TS lvl NOT USED 24 X36- SCALE: N.T.S. t1'X77' SCALE' NJ S. NOT USED1 24-X36" SCALE: N.T.S. 19w LLX 17' SCALE. NJ S. <>. NOT USED( 24-X06" SCALE: N.T.S. O LLXL7" SCALDAS__ <>, NOT USED 24'Ii$6" SCALE: N.Y.S. 1_t_%.17- SCALE. NS.S ME TA DEF—Yri TYPE NC TYPE SS TYPE W TYPF_VS TYPE VR TYPE PT TYPE GT 14 TYPE GY TYPE GR /6 AWG FROM ANTENNA CABLE GROUND KIT COPPER GROUND BAR ON WALL, ICE BRIDGE. FLOOR OR ON ANTENNA TOWER CADWELD GROUNDING CONNECTIONS( A 24"X36" SCALE: N.T.S ` A U_'X]7' SCAI' NJ S_ /\ Ovra(78 0 00 00 ',TWO HOLE LUG. OR EXOTHERMIC WELD TO BE USED WITH B2 AWC BCW TO BUILDING SERVICE GROUND OR GROUND RING NOTE GROUND BARS AT BOTTOM OF TOWERS/MONOPOLES SHALL ONLY USE EXOTHERMIC WELDS. GROUNDWIRE INSTALLATION 24X36 SCALE: N.T.S. 1_17)(11- SCALE- NJS NOT USED1( 24-X36" SCALE: N.T.S. 13„ 11'X17' SCALE. NJ S. U NOT USED/ 24-Or SCALE: N.T.S. 1 1'X 17' SCAI F' NJ S. J� NOTE: COAT ALL MECHANICAL CONNECTIONS WITH 'N00x' OR APPROVED EOUAL NOT USED i Z 24'x36' SCALE: N.T.S. 11'X17' SCAIF. NTS NOT USED 24-X36" SCALE: N.T.S. 11-X17' SCAI,. NTS COAXIAL GROUND KITS W/ LONG BARREL COMPRESSION DOUBLE LUGS, ATTACH TO GROUND BAR & INSTALLED BY ANTENNA CONTRACTOR COPPER GROUND BAR, INSTALLED BY 1-- GENERAL CONTRACTOR O O O O 0 C 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O. 0 0 7.0.0„ 0 _O ....0, 0 0 0 0 0 0 O 24- VERIFY R2 SOLID BARE TINNED COPPER WIRE O GROUND B ANTENNA CABLE WEATHERPROOFING KIT (SEE NOTE 3) CABLE GROUND KIT #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR). SEE NOTE 1 & 2 CABLE CONNECTOR (TYPICALLY) 12- TO 24- NOTES' 1. DO NOT INSTALL CABLE GROUND KR AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. CABLE GROUND KIT CONNECTION 24"X36 SCALE: N.T.S. 11'X1.7' SCALE' NJ S. TO ANTENNAS COAX JUMPER (TYP.) CONNECTOR WEATHERPROOFING KIT (TYP.) ANTENNA CABLE TO BTS EOUIPMENT (TYP.) NOTES: 00 NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 24%36" SCALE: N.T.S 11-X17 SCAIF' N T S WEATHERPROOFING KIT (TYP.) GROUND KIT (TYP.) b6 AWG ANTENNA GROUND BAR COPPER ANTENNA GROUND BAR. BONDED DIRECTLY TO TOP OF MONOPOLE OR UTILRY POLE TO GROUND RING WEATHER PROOFING SHALL BE TWO-PART TAPE KR. COLD SHRINK SHALL NOT BE US GROUNDING CABLE CONNECTION Giotel >Integrity DeliveredTM •:IasTec Network Solutions RFDS: V 2.0. DATED: 02/01/2018 WA6158 ROXBURY 10710 WEST MARGINAL WAY S TUKWILA, WA98168 KING COUNTY \ EXPIRES 01-09-2019 / REVISIONS REV. OATS DESCRU ON BY A W/H/IE ISSUED FOR 10M CD REVl0M Pi 0 04/30/l4 !SUED FOR 1001 CONS -MU 000 OUR • r.:filr , ,lilVrooSy e'opment TITLE GROUNDING DETAILS [SHEET E2 J 24"X17" SCAIF NTS (GLOTEL PROJECT It: J5568)