CSS 2026-06-22 Item 1A - Contract - Foster Golf Course Pump House Replacement with Watertronics LLC
City of Tukwila Thomas McLeod, Mayor Marty Wine, City Administrator AGENDA BILL ITEM NO. U.A. Agenda Item Sponsor Legislative History ContractApproval: Foster Golf Links Pump House Replacement David Rosen, Analyst Parks fkRecreation June 22.2O26 Community Services & Safety Committee July 20, 2026 Regular Meeting Consent Agenda Recommended Motion [] Discussion Only 0 Action Requested MOVE TO authorize the execution of contract with VVatertrunioa LLC. |nthe amount Of$2G7,0OOfor procurement 0f8replacement pump station for Foster Golf Links. EXECUTIVE SUMMARY The City of Tukwila Parks and Recreation Department seeks to replace the aging pump station located 8tFoster Golf Links, this project w8Sp|8DnedfOrinthe2025-2030C@pit8||nOpr0vemeniPrOgnB0 (C|P)and ialisted auP jeot#110411O7.ThiapumpatoUonpruvideawaterbzthecourau'uerdire irrigation system and is past its expected service life with replacement parts becoming harder to source efficiently and effectively. The Parks and Recreation Department, per city policy, seeks council approval for the mayor to execute a contract for procurement of replacement pump station equipment. Department staff request the Community Services and Safety Committee forward this item to the July m �0 Regular Meeting Consent Agenda for council approval. DISCUSSION The pump house at Foster Golf links is the central facility that draws, pP8SSU[izeS' and distributes water from the [JUVV8DliSh River to the golf course's irrigation Sva[eDl. Any dOVVO|iDl8 and/or failure of the pump house system jeopardizes short and long-term course playability and therefore golfer experience, therefore @ n8|iGb|9 and efficient pump house is CriUCG| for maintaining revenue generation. The pump house located at Foster Golf Links has been in service since 1995. and due to its increasing aga, it is becoming inefficient to operate and service with n}p|8Cennent/nnGint8n@nC8 parts and 8SSetG becoming harder to S0urC8 from and on behalf 0fvendors and/or contractors. Because Ofthis, staff planned for its eventual replacementiDthe 2025-2028biennium @Spart Ofthe 2025 — 2030 C|P. The estimate for the project at that time was approximately $200.000. the p j8CyS cost has increased due to overall inflationary impacts as well as inflation more specifically concentrated inmachinery and equipment such GSthe pump house being procured. In addition to the system having obsolete p@rts, it is also missing kevfunoUnno|UUes offered by newer systems. Per example, newer pump house systems include the ability to remotely monitor system operations, allowing for real-time control of systems. The current pump house does not possess this fun(tione|ity, requiring the FGL Course Superintendent to spend staff time travelling to the site to manually operate the pump house controls when needed. Additionally, the current pump house filter system cannot be serviced in-house, requiring a crane truck to be rented for servicing, the new pump house system will not require this, saving an approximate $5,000 in operating costs annually. In sum, replacement of the aging pump house at Foster Golf Links will: 1. Improve system reliability and serviceability 2. Conserve water through more efficient systems and monitoring capabilities, and 3. Increase staff time available for other course/business needs The pump station replacement is estimated to be completed in either Q4 2026 or Q1 2027, depending on machinery lead times and availability of professional installation services. The project timeline as proposed ensures the new pump house is installed, tested, and optimized for ongoing operations before the courses' busier season begins in Q2 2027. FINANCIAL IMPACT Complete for all items requiring City expenditure Disclaimer: Final terms and scope of work subject to review by the City Attorney © Budgeted El Unbudgeted El Grant -Funded Expenditure Required: Fund Source: $267,000 Fund 411 Fund Balance Contractor Watertronics LLC. Scope of Work Scope includes: 1. Construction of custom pump house and system specific Foster Golf Links' setup and needs 2. Delivery of system and setup utilizing the existing pump house structure and utilities onsite 3. No optional equipment features included (Station Heater) Amount $267,000 Please note: 1. The quote price on the attachment does not include Sales Tax, it has been included in the proposed contract 2. Staff have added a 10% escalation to the quote for the contract in case of cost overruns and/or price increases Duration Delivery expected by Q4 2026 Additional Comments: of pump house system; installation will be a separate contract staff are different contractor, staff have ensured this contractor meets the from the pump house system provider to maintain the system's warranty. is anticipated to include removal of the existing system but not complete potentially sell components that have value or retain them as backups in Contract is for procurement currently scoping with a requirements necessary The installation contract disposal, allowing staff to case of need. ATTACHMENTS A — Proposed Contract for Services + Custom Pump System Quotation (FosterGolfLinks_260604Q7) B — Foster Golf Links Pump House Replacement Engineering Drawings 3 City of Tukwila 6200 Southcenter Boulevard, Tukwila WA98188 CONTRACT FOR SERVICES Contract Number: This Agreement is entered into by and between the City of Tukwila, Washington, a non -charter optional municipal code city hereinafter referred to as "the City," and Watertronics LLC., hereinafter referred to as "the Contractor," whose principal office is located at P.O Box 530 Hartland, WI 53029. WHEREAS, the City has determined the need to have certain services performed for its citizens but does not have the manpower or expertise to perform such services; and WHEREAS, the City desires to have the Contractor perform such services pursuant to certain terms and conditions; now, therefore, IN CONSIDERATION OF the mutual benefits and conditions hereinafter contained, the parties hereto agree as follows: 1. Scope and Schedule of Services to be Performed by Contractor. The Contractor shall perform those services described on Exhibit A attached hereto and incorporated herein by this reference as if fully set forth. In performing such services, the Contractor shall at all times comply with all Federal, State, and local statutes, rules and ordinances applicable to the performance of such services and the handling of any funds used in connection therewith. The Contractor shall request and obtain prior written approval from the City if the scope or schedule is to be modified in any way. 2. Compensation and Method of Payment. The City shall pay the Contractor for services rendered according to the rate and method set forth on Exhibit A attached hereto and incorporated herein by this reference. The total amount to be paid shall not exceed $267,000 for the services described in Exhibit A. 3. Contractor Budget. The Contractor shall apply the funds received under this Agreement within the maximum limits set forth in this Agreement. The Contractor shall request prior approval from the City whenever the Contractor desires to amend its budget in any way. 4. Duration of Agreement. This Agreement shall be in full force and effect for a period commencing July 24th, 2026, and ending February 28th, 2027, unless sooner terminated under the provisions hereinafter specified. 5. Indeoendent Contractor. Contractor and City agree that Contractor is an independent contractor with respect to the services provided pursuant to this Agreement. Nothing in this Agreement shall be considered to create the relationship of employer and employee between the parties hereto. Neither Contractor nor any employee of Contractor shall be entitled to any benefits accorded City employees by virtue of the services provided under this Agreement. The City shall not be responsible for withholding or otherwise deducting federal income tax or social security or contributing to the State Industrial Insurance Program, or otherwise assuming the duties of an employer with respect to the Contractor, or any employee of the Contractor. 6. Indemnification. The Contractor shall defend, indemnify and hold the Public Entity, its officers, officials, employees and volunteers harmless from any and all claims, injuries, damages, losses or suits including attorney fees, arising out of or in connection with the performance of this Agreement, except for injuries and damages caused by the sole negligence of the Public Entity. CA Revised May 2020 Page 1 of 4 4 Should a court of competent jurisdiction determine that this Agreement is subject to RCW 4.24.115, then, in the event of liability for damages arising out of bodily injury to persons or damages to property caused by or resulting from the concurrent negligence of the Contractor and the Public Entity, its officers, officials, employees, and volunteers, the Contractor's liability hereunder shall be only to the extent of the Contractor's negligence. It is further specifically and expressly understood that the indemnification provided herein constitutes the Contractor's waiver of immunity under Industrial Insurance, Title 51 RCW, solely for the purposes of this indemnification. This waiver has been mutually negotiated by the parties. The provisions of this section shall survive the expiration or termination of this Agreement. 7. Insurance. The Contractor shall procure and maintain for the duration of the Agreement, insurance against claims for injuries to persons or damage to property which may arise from or in connection with the performance of the work hereunder by the Contractor, their agents, representatives, employees or subcontractors. Contractor's maintenance of insurance, its scope of coverage and limits as required herein shall not be construed to limit the liability of the Contractor to the coverage provided by such insurance, or otherwise limit the City's recourse to any remedy available at law or in equity. A. Minimum Scope of Insurance. Contractor shall obtain insurance of the types and with the limits described below: 1. Automobile Liability insurance with a minimum combined single limit for bodily injury and property damage of $1,000,000 per accident. Automobile liability insurance shall cover all owned, non -owned, hired and leased vehicles. Coverage shall be written on Insurance Services Office (ISO) form CA 00 01 or a substitute form providing equivalent liability coverage. If necessary, the policy shall be endorsed to provide contractual liability coverage. 2. Commercial General Liability insurance with limits no less than $2,000,000 each occurrence, $2,000,000 general aggregate and $2,000,000 products -completed operations aggregate limit. Commercial General Liability insurance shall be as least at broad as ISO occurrence form CG 00 01 and shall cover liability arising from premises, operations, independent contractors, products -completed operations, stop gap liability, personal injury and advertising injury, and liability assumed under an insured contract. The Commercial General Liability insurance shall be endorsed to provide a per project general aggregate limit using ISO form CG 25 03 05 09 or an equivalent endorsement. There shall be no exclusion for liability arising from explosion, collapse or underground property damage. The City shall be named as an additional insured under the Contractor's Commercial General Liability insurance policy with respect to the work performed for the City using ISO Additional Insured endorsement CG 20 10 10 01 and Additional Insured -Completed Operations endorsement CG 20 37 10 01 or substitute endorsements providing at least as broad coverage. 3. Workers' Compensation coverage as required by the Industrial Insurance laws of the State of Washington. B. Public Entity Full Availability of Contractor Limits. If the Contractor maintains higher insurance limits than the minimums shown above, the Public Entity shall be insured for the full available limits of Commercial General and Excess or Umbrella liability maintained by the Contractor, irrespective of whether such limits maintained by the Contractor are greater than those required by this Contract or whether any certificate of insurance furnished to the Public Entity evidences limits of liability lower than those maintained by the Contractor. C. Other Insurance Provision. The Contractor's Automobile Liability and Commercial General Liability insurance policies are to contain, or be endorsed to contain that they shall be primary insurance with respect to the City. Any insurance, self-insurance, or insurance pool coverage maintained by the City shall be excess of the Contractor's insurance and shall not contribute with it. D. Acceptability of Insurers. Insurance is to be placed with insurers with a current A.M. Best rating CA Revised May 2020 Page 2 of 4 5 of not less than A: VII. E. Verification of Coverage. Contractor shall furnish the City with original certificates and a copy of the amendatory endorsements, including but not necessarily limited to the additional insured endorsement, evidencing the insurance requirements of the Contractor before commencement of the work. Upon request by the City, the Contractor shall furnish certified copies of all required insurance policies, including endorsements, required in this Agreement and evidence of all subcontractors' coverage. F. Subcontractors. The Contractor shall cause each and every Subcontractor to provide insurance coverage that complies with all applicable requirements of the Contractor -provided insurance as set forth herein, except the Contractor shall have sole responsibility for determining the limits of coverage required to be obtained by Subcontractors. The Contractor shall ensure that the Public Entity is an additional insured on each and every Subcontractor's Commercial General liability insurance policy using an endorsement as least as broad as ISO CG 20 10 10 01 for ongoing operations and CG 20 37 10 01 for completed operations. G. Notice of Cancellation. The Contractor shall provide the City and all Additional Insureds for this work with written notice of any policy cancellation, within two business days of their receipt of such notice. H. Failure to Maintain Insurance. Failure on the part of the Contractor to maintain the insurance as required shall constitute a material breach of contract, upon which the City may, after giving five business days notice to the Contractor to correct the breach, immediately terminate the contract or, at its discretion, procure or renew such insurance and pay any and all premiums in connection therewith, with any sums so expended to be repaid to the City on demand, or at the sole discretion of the City, offset against funds due the Contractor from the City. 8. Record Keeping and Reporting. A. The Contractor shall maintain accounts and records, including personnel, property, financial and programmatic records which sufficiently and properly reflect all direct and indirect costs of any nature expended and services performed in the performance of this Agreement and other such records as may be deemed necessary by the City to ensure the performance of this Agreement. B. These records shall be maintained for a period of seven (7) years after termination hereof unless permission to destroy them is granted by the office of the archivist in accordance with RCW Chapter 40.14 and by the City. 9. Audits and Inspections. The records and documents with respect to all matters covered by this Agreement shall be subject at all times to inspection, review or audit by law during the performance of this Agreement. 10. Termination. This Agreement may at any time be terminated by the City giving to the Contractor thirty (30) days written notice of the City's intention to terminate the same. Failure to provide products on schedule may result in contract termination. If the Contractor's insurance coverage is canceled for any reason, the City shall have the right to terminate this Agreement immediately. 11. Discrimination Prohibited. The Consultant, with regard to the work performed by it under this Agreement, will not discriminate on the grounds of race, religion, creed, color, national origin, age, veteran status, sex, sexual orientation, gender identity, marital status, political affiliation, the presence of any disability, or any other protected class status under state or federal law, in the selection and retention of employees or procurement of materials or supplies. 12. Assignment and Subcontract. The Contractor shall not assign or subcontract any portion of the services contemplated by this Agreement without the written consent of the City. 13. Entire Agreement: Modification. This Agreement, together with attachments or addenda, represents the entire and integrated Agreement between the City and the Contractor and supersedes all prior negotiations, representations, or agreements written or oral. No amendment or modification of this Agreement shall be of any force or effect unless it is in writing and signed by the parties. CA Revised May 2020 Page 3 of 4 6 14. SevemabiUity and SmrwhwaU' If any tumn, condition or provision of this Agreement is declared void or unenforceable or limited in its @pp|iC8tOD or effect, such event Sh@U not affect any other p[OViSiOnS hereof and all other provisions shall remain fully enforceable. The provisions of this Agreement, which bvtheir sense and context are reasonably intended tosurvive the completion, expiration orcancellation of this /\OPg8DleDL' Sh8|| survive Le[OliD@iiOD of this Agreement. 15. Notices. Notices to the City of Tukwila shall be sent to the following address: City Clerk, City OfTukwila 62OOGouthmenLerBlvd. Tukwila, Washington 98188 Notices 0othe Contractor shall be sent tothe address provided bvthe Contractor upon the SigO@tUP8 |iD8 below. 16. AWDDUicmb|e Law: Venue: A*tommey's Fees' This Agreement ehoU be governed by and construed in accordance with the laws of the State of Washington. In the evert any suit, orbitroUon, or other proceeding is instituted to enforce any term of this Agreement, the parties specifically understand and agree that venue Sh8|| be properly laid in King County, Washington. The prevailing party in any such action shall be entitled toits ottorney'afees and costs ofsuit. DATED this 15 th day of June, 2026. City signatures to be obtained by Contractor signature to be obtained by City Clerk's Staff ONLY. -* sponsor staff. ** CITY OF TUKWILA Thomas McLeod, Mayor ATTEST/AUTHENTICATED: Andy Youn-Barnett, City Clerk APPROVED AS TO FORM: Office of the City Attorney Printed Name: Address: CARevised May 202O Page 4nf4 CUSTOM PUMP SYSTEM Watertronics LLC. P.O. Box 530 Hartland, WI 53029 PH: 262-367-5000 FX: 262-367-6897 QUOTATION Project Name: Site Location: Foster Golf Links Tukwila,WA Date: 6/15/2026 Quotation: FosterGolfLinks_260604Q7 Quoted By: Drew Palmer Customer Contact Name: Company Name: Address: Phone: Email: Mr. Ryan Rosevear Foster Golf Links 13500 Interurban Ave S 206-242-4221 ryan.rosevear@tukwilewa.gov Sales Rep: Drew Palmer Phone: 262-399-8185 Email: drew.palmer@watertronics.com Performance: Site Voltage: Model Number: 1000GPM @ 90PSI 480Y/277 volt, 3Phase/60Hz only VTV-7C-40X2/5ST-480-3-1000-90 Wetwell Depth: 17Ft. - 8in. Panel SCCR: 35KA FCC Type: None Project Scope Replacement pump station for Foster Golf Links in Tukwila, WA. Pump station is capable of producing up to 1000gpm @ 90psi. Pump station is designed to handle the secondary reclaim water source. Stainless Steel heat exchanger cooling for control panel Fusion Bonded Epoxy (2M Scotchkote 134) coating on internals of all station piping Stainless Steel pump columns on all pumps Intake and discharge filtration (with controls) are included. Freight and certified start-up are INCLUDED. CATEGORY DESCRIPTION QTY Approvals and Certifications Paint Color Pump Motors - Submersible Pump Motors - VHS Pumps - Submersible Turbine Pumps - Vertical Turbine Pump Discharge Heads Pump Columns Pump Columns Pump Seals Discharge Manifolds Pressure Relief Valves Discharge Filters Regulation EBVs Flow Meters Level Controls Inlet Screens Pipework Coatings Pump Station Bases Wet Well Cover Plates Pump Station Base Accessories • UL Listed - Industrial Control Panel • Paint Color - Watertronics - Green • 5HP Submersible Motor - 380-460V/3ph • 40HP VHS Premium Efficiency Motor - 460V/3Ph • Pump, Submersible Turbine, 5HP • Pump, Vertical Turbine, 11IDLH-4 • Discharge Head - 6" Ductile Iron • Pressure Maint Pump Column - 2" Dia - 304 SS • VT Pump Column - 6" Dia, 3 Piece, 304SS • Mechanical Shaft Seal • Discharge Manifold - Duplex Pump • 3" Pressure Relief Valve • Filter, Forsta D8-180-304 - 8 Flange 2000GPM, 300 micron • Electronic Butterfly Valve - 2-6" • Growsmart IM3000 Series Magnetic Flowmeter - 6" • Wetwell Level Control w/1 Pond Fill • Self Cleaning Inlet Screen - 1350 GPM • Fusion Bonded Epoxy - Internal Only • Pump Station Base - Formed Steel • Wet Well Cover Plate - 4 Square Feet • Skid Shim Kit, Stainless Steel FosterGolfLi n ks_260604Q7 8 1 of 13 Disconnects VFDs XL Contactors XL Contactors Control System Control System Touchscreen Displays Control Switches Surge Protection Optical Devices Optical Devices Remote Start Options Communication and RTUs Fertigation Accessories Fertigation Accessories Electrical Enclosure Electrical Enclosure Accessories Electrical Enclosure Cooling Documentation • Station Disconnect Switch - 200A Fused • Variable Frequency Drive, 40HP, 380-480V/3ph • VFD (XL) Contactor - 460-575V/3Ph - 40HP • Motor Starter - 460-575V/3Ph - 5HP • Power - Phase Monitor Protection • Type 7C - M262 PLC • 10" ComFile HMI Edge CPU • Lighted HOA Switch • Standard Surge/Lightning Protection • Flow Signal Opto Coupler - For Sharing Signal • Flow Sensor Opto Isolator • Remote Disable Relay - 24VAC/DC • WaterVision - 7C Controls - Verizon 3 Year • Fertigation Run Relay • Chemical Treatment Relay • Electrical Enclosure - 75x48x16 STL/WHT • Control Panel Leg Kit - 6"H x 16"D • Heat Exchanger - N4X Stainless Steel - (3350 Btu) • Operation & Maint Manual (English) - Electronic Copy FosterGolfLinks 260604Q7 2 of 13 9 STANDARD EQUIPMENT FEATURES : nc uded In Total Stat on Price; OPTION NO DESCRIPTION QTy 001-0000008 Vertical Turbine - Station Spec • A variable speed Vertical Turbine pump station shall be provided. The pump station shall include variable frequency drive speed control vertical turbine pumps piping valves electrical panel base and all other features (where applicable as specified below). Station shall be designed to be installed either outside or inside a weather resistant building furnished by the owner as specified above. A formed and reinforced base platform will support all manifolding pumps motors and control panels to provide an integral unit ready to quickly install at the job site. Configuration of station inlet discharge power connections and layout/orientation of basic system components shall be indicated on the sales drawing. The station shall be completely assembled (where applicable) calibrated and subjected to a dynamic run test including safety check prior to breakdown and shipment to customer. 005-0000002 UL Listed - Industrial Control Panel • The station ELECTRICAL CONTROL PANEL shall be UL listed and meet or exceed UL508A specifications for safety of industrial control panels. Panel shall be assembled and tested in a UL508A certified panel shop. 010-0000001 Paint Color - Watertronics - Green • Pump station pumping components shall be painted Watertronics GREEN for maximum durability and resistance to corrosion. The paint system shall consist of a multi -step system including media blasting application of a rust prohibitive epoxy prime coat followed by a two part industrial grade ultraviolet resistant polyurethane finish having a total dry film thickness of not less than 5 mils. Each coat will be applied and baked for one half hour at 165 degrees F. Pump station components including base pipework discharge heads manifolds isolation and relief valves grooved clamps and supports shall be painted unless otherwise specified on sales drawing. 100-0000009 5HP Submersible Motor - 380-460V/3ph 101-0000013 • A 5HP high efficiency submersible motor shall be provided. The motor shall be inverter duty rated class F windings and shall be fully sealed with stainless steel splined output shaft. 40HP VHS Premium Efficiency Motor - 460V/3Ph 2 • A 40HP premium efficient (VHS) vertical hollow shaft motor shall be provided. The motor shall be inverter duty rated class F windings and include internal 120V winding heaters. The motor shall be sized properly for continuous operation of the pump at any point along the designed pump performance curve without exceeding the motors specified horsepower rating. The motor shall be equipped with a "Self Release Coupling" factory configured (bolted to upper bearing) for momentary up thrust protection. 120-0000002 Pump, Submersible Turbine, SHP 121-0000102 • A 5HP Submersible Turbine pump shall be provided. The pump shall consist of one or more stages and be designed for maximum performance and efficiency. Bowls shall be made of cast iron or stainless steel. Impellers shall be investment cast stainless steel. Pump, Vertical Turbine, 11IDLH-4 2 140-0000002 • A Vertical Turbine pump assembly shall be provided. The pump assembly shall consist of one or more stages designed and manufactured by Watertronics in order to achieve maximum performance and efficiency. Standard features shall include ductile iron bowls with 0-ring seals between each stage polymer bearings rated for 4 minute dry run 304 STAINLESS STEEL impellers, 18/8 stainless steel fasteners and a stainless steel inlet basket strainer properly sized for the pump. Each pump assembly shall be factory tested to Hydraulic Institute ANSI/HI 14.6 acceptance grade 2B. Discharge Head - 6" Ductile Iron 2 • A heavy duty ductile iron 6 INCH pump discharge head assembly shall be provided for superior durability. The discharge head assembly shall include a check valve butterfly valve and related hardware flow rated for up to 900GPM and 150 PSI per ANSI B2.1. FosterGolfLinks 260604Q7 3 of 13 10 150-0000020 Pressure Maint Pump Column - 2" Dia - 304 SS 150-0000043 • A 2 INCH diameter pressure maintenance pump column pipe shall be provided. The column pipe shall be fabricated from 304 STAINLESS STEEL. A butterfly valve and check valve shall be provided on the outlet of the column pipe assembly. VT Pump Column - 6" Dia, 3 Piece, 304SS 2 180-0000002 • A 3 Piece 6 INCH diameter vertical turbine pump column and shaft assembly shall be provided. The column pipe shall be fabricated from 304 STAINLESS STEEL pipe. Pump line shafts and bowl shafts shall be fabricated from 17-4PH STAINLESS STEEL. The shaft diameter shall be no less than prescribed by ANSI B58.1 Section 4.2 Table 4. Bearing retainers shall be stainless steel with polymer bearings. The column and shaft assembly shall be designed per the total pump length specified on the sales drawing. Mechanical Shaft Seal 2 • Each turbine pump discharge head shall contain a mechanical seal assembly located where the line shaft protrudes through the discharge head. The mechanical seal assembly shall consist of a main housing shaft sleeve assembly locking and drive collars. The shaft sleeve shall be machined from 416 stainless steel. The locking and driving collars shall be machined from 7075 aluminum. Integral to the seal housing a permanently lubricated ball bearing shall be mounted located out of the pumping media. The mechanical seal shall be resistant to corrosion and abrasives totally self lubricating and rated for no less than 300 PSI. The seal assembly shall require no bypass tubes or related devices to provide cooling or lubrication. One seal required per Vertical Turbine pump. 200-0000002 Discharge Manifold - Duplex Pump • A custom fabricated DUPLEX PUMP discharge manifold shall be provided. The manifold shall be designed and fabricated by Watertronics to maximize flow and efficiency and to meet specific customer installation requirements. All fabricated piping shall conform to ASTM specifications A53 for Grade B welded or seamless pipe. Discharge piping 12" and larger shall be a minimum "Standard Wall" thickness. Discharge piping 10" and smaller shall be Schedule 40. All welded flanges shall be forged steel slips€'on or weld neck type. All welded fittings shall be seamless conforming to ASTM Specification A234 with pressure rating not less than 150 psi. The manifold assembly shall include a main discharge isolation valve discharge pressure gauge three 3/4" fertigation ports and a winterization drain port with 3/4" ball valve. 210-0000001 3" Pressure Relief Valve • A 3" pressure relief valve shall be installed on the discharge piping downstream of the pressure regulating valves. The valve shall be sized to bypass sufficient water back to the water source to avoid the discharge pressure from exceeding the maximum programmed pressure set point by more than 10 PSI. 230-0000015 Filter, Forsta D8-180-304 - 8 Flange 2000GPM, 300 micron 270-0000001 • A Forsta D8-180-304 series filter shall be provided for superior discharge filtering performance. The filter body shall be fabricated from 304 stainless steel and pickle passivated and the screen shall be 316 stainless steel and include an automatic flush system. The flush cycle shall be fully programmable be controlled by the system PLC and initiated by pressure drop across the filter or on a time interval basis. Flushing shall be controlled by an industrial grade electronic valve actuator and shall occur during normal operation without suspension of the normal irrigation process. Filter assembly includes inlet and outlet isolation valves and includes a filter bypass where applicable as specified on the sales drawing. Maximum flow rate shall be 2000GPM per filter with 300 micron screen. Electronic Butterfly Valve - 2-6" 2 • A patented Watertronics 2-6" EBV "Electronic Butterfly Valve" shall be provided on the pump discharge head. The EBV shall provide for gradual entry of water from the pump into the discharge manifold to allow for complete purging of pump column air and elimination of water hammer surges and check valve slam. The EBV shall also facilitate smooth pump sequencing enhanced flow and pressure regulation. In the event of a VFD failure the EBV shall function as a by-pass regulation device to maintain constant pressure regulation and flow without disruption of the irrigation process. FosterGolfLinks 260604Q7 4 of 13 11 280-0000011 Growsmart IM3000 Series Magnetic Flowmeter - 6" • A 6" diameter Growsmart electromagnetic flow meter shall be provided to measure water flow rate with an accuracy of +/- 2%. The flowmeter shall include an integrated LCD display and be constructed of epoxy coated ASTM carbon steel suitable for indoor or outdoor installation. Maximum recommended flow rate 1322 GPM. 290-0000001 Wetwell Level Control w/1 Pond Fill • A robust industrial grade WETWELL level control system shall be provided. The system shall consist of a level transducer and a low level safety shutdown float located in the WETWELL for accurate and reliable level control. The controls shall be fully integrated with the control system with programmable set points accessible through the station touchscreen display. The level control system shall function to shutdown the pump system in the event of a low water condition. An additional isolated 5A relay contact shall be provided for control of ONE external pond fill or other external fill source. The level transducer shall be rated for a maximum water depth of 33.5 feet. 310-0000010 Self Cleaning Inlet Screen - 1350 GPM • A Self Cleaning - 1350 GPM Inlet Screen shall be provided to prevent debris from entering pump inlet . The screen shall be cylindrical in shape and equipped with a jet pipe assembly for removal of screen debris during the flush cycle. The screen assembly shall be fabricated from stainless steel with a POWDER COATED STEEL connection flange. A flush supply line and solenoid control shall be provided where applicable. Flush requires 25GPM for proper operation. Inlet flume pipe and adapters not included and are to be ordered separately. 395-0000001 Fusion Bonded Epoxy - Internal Only • 3M Scotchkote Fusion -Bonded Epoxy Coating 134 shall be applied to INTERNAL ONLY pipe surfaces as indicated by the sales drawing. 3M Scotchkote 134 is a one part heat curable thermosetting coating that cures to a smooth uniform thickness provides superior adhesion coverage on porous pipework and is highly resistant to wastewater corrosive soils and sea water. 400-0000001 Pump Station Base - Formed Steel • Pump station components shall be mounted on a formed steel base. Formed steel construction is used to minimize weld seams and maximize strength. The base material shall be 3/8" thick ASTM A-26 hot rolled carbon steel plate. Structural steel shall be welded on the underside of the base to maximize structural rigidity. Base shall have a minimum of 8 (eight) lifting points (two at each corner). Base shall include a hinged wet well hatch whenever possible. Base shall be supplied with four anchor brackets and concrete wedge anchor bolts if base length is under 12ft. For base lengths over 12ft six anchors shall be provided. 401-0000004 Wet Well Cover Plate - 4 Square Feet • A 3/8" diamond plated aluminum cover plate shall be provided to cover any exposed gap between the edge of the skid and the wall of the wet well. A bracket will be provided so that the cover plate can be securely fastened to the side of the skid. The cover plate will also have through holes in each corner for anchoring to the concrete slab. 410-0000001 Skid Shim Kit, Stainless Steel • A skid shim kit shall be provided to take up small gaps between skid and floor and to insure level installation of skid. Each kit shall include the following stainless steel shims; Qty (2) - 1/2"x2"x5" Qty(2) - 3/8"x2"x5" Qty(4) - 1/4"x2"x5" Qty(4) - 1/8"x2"x5". 500-0000011 Station Disconnect Switch - 200A Fused • A 3-pole 200 amp maximum FUSED UL Listed main disconnect switch shall be provided. The disconnect switch shall include an operating handle mounted in the main electrical panel door that shall open all ungrounded conductors of the service entrance to the panel. The disconnect switch shall be mechanically interlocked to prevent access while the operating handle is in the ON position. The station disconnect switch shall be correctly sized for the maximum station load and shall meet all applicable NEC and UL508A requirements. 520-0000026 Variable Frequency Drive, 40HP, 380-480V/3ph FosterGolfLinks 260604Q7 5 of 13 12 540-0000036 • A high efficiency industrial grade 40HP variable frequency drive shall be provided. The VFD shall be specifically designed for water pumping applications and include a graphical control interface keypad. All internal printed circuit boards shall be conformal coated for long service life. VFD (XL) Contactor - 460-575V/3Ph - 40HP 2 • A 460-575V/3Ph - 40HP cross line (XL) industrial grade dual interlocking contactor set shall be provided for the pump. The contactor set shall allow the assigned pump to be run manually across the line or from the VFD output. It will also facilitate sequencing of pumps when more than one main pump is present. An HOA (Hand -Off -Auto) switch will be provided for each pump. When HOA is in Hand position the contactor set will engage to power pump directly across the line. If Off position pump will be disabled and when in Auto pump will run on VFD when assigned as lead pump otherwise the contactor set will sequence the pump on as a lag pump where applicable. 540-0000070 Motor Starter - 460-575V/3Ph - 5HP • A 460-575VAC/3Ph - 5HP industrial grade Motor Starter shall be provided. The motor starter shall provide integrated switching thermal and current overload protection per NEC article 430 safety requirements. The switching contacts shall be rated for a minimum of 200000 cycles under full load conditions. 600-0000003 Power - Phase Monitor Protection • An advanced microprocessor based Power Phase Monitoring system shall be provided to protect the pump system from equipment failure due to power faults occurring on the incoming electrical service to the pump station. The monitor shall actively monitor for phase loss phase reversal phase unbalance under voltage and overvoltage conditions. In the event that these one or more of these conditions occur the Phase Monitor shall signal the PLC logic controller to shut down the pump system preventing damage to pump system components. The phase monitor fault limits and time to trip shall be adjustable. A status LED shall indicate the fault type causing the shutdown event. 600-0000004 Type 7C - M262 PLC • The electrical control system shall be an Industrial grade PLC with custom programming written specifically for this project. Control logic shall be based on redundant design and interlocking of control devices for maximum safety and proper sequence of operation. The PLC controller shall have diagnostic LEDs for monitoring status of discrete inputs and outputs as well as a general PLC error feedback. The PLC shall contain RS485 and Ethernet communication ports for monitoring and programming purposes. The PLC will have a high speed counter clock and calendar function with year month day hour minute and day of week. 610-0000006 10" ComFile HMI Edge CPU 620-0000001 • An industrial grade 10.1" (1024 x 600) LCD touchscreen user interface display shall be provided for monitoring and diagnostic purposes featuring: Digital flow (GPM) and pressure (PSI) display. Both cumulative and resettable gallons pumped indicators. Pump ready/running status with elapsed run time display per pump. Flow -based pressure regulation to match discharge pressure with irrigation demand Individual motor overload reporting Minute by minute data logging saved internally for Historic and real time X-Y plotting of pump station operation. Filter controls. Alarm log. Ability to change system parameters such as setpoint pressure time delays Fertigation graphic and control interface when sold with a Watertronics EZ Feed Injection Package. Life of the display shall be 50000 hours. The display software shall be configured for the pump station features. Lighted HOA Switch 3 • A lighted switch actuator shall be provided which shall be illuminated GREEN whenever the controlled item is active. One required per switch. 630-0000001 Standard Surge/Lightning Protection FosterGolfLinks 260604Q7 6 of 13 13 • A Standard 40kA max impulse current rated surge protective device shall be provided on the incoming power connections to the station. The SPD shall utilize high energy solid state suppression circuitry to effectively protect electrical equipment from severe electrical disturbances. Diagnostic LEDs shall be provided on the device to indicate operational status of the device when powered. 640-0000001 Flow Signal Opto Coupler - For Sharing Signal • An optical coupling device shall be provided for sharing of pump station flow signal with external customer control systems. The opto-coupler is rated for 3-30VDC (24VDC) nominal supply from customer control system and shall provide a minimum of 2500V isolation between station control system and external systems. 640-0000002 Flow Sensor Opto Isolator • An optical isolation device shall be provided for isolating OFF SKID station flow sensor from the control system. The optical isolator shall effectively improve flow signal quality and eliminate interference ground loops and other signal disturbances from entering station control electronics. 650-0000003 Remote Disable Relay - 24VAC/DC • A 24VAC/DC remote disable relay input shall be provided. The remote disable relay shall effectively disable the pump station when the remote start relay coil is supplied 24VAC/DC power from an irrigation controller or other external power source provided by customer. If the station is running and relay is powered the station will safely shutdown. When power is removed from the relay the station will return to normal operation. 680-0000018 WaterVision - 7C Controls - Verizon 3 Year • WaterVision - Verizon network CELLULAR remote pump system monitoring package shall be provided. The system includes all hardware software and 3 YEAR SUBSCRIPTION for connection of a single pump station to the WaterVision Network via a cellular connection. The system shall allow customer to remotely monitor the pump station and the customer's other WaterVision enabled pump stations on the same property or multiple properties at any time from a cell phone tablet PC or other web based device. The system shall also allow control of the pump station including enable/disable and reset of alarms. The WaterVision system is also expandable through connection of additional WaterVision enabled pump systems. Additional hardware is required for system expansion. Contact PSN for future subscription pricing. 720-0000001 Fertigation Run Relay • A Fertigation Run relay shall be provided to activate a customer provided chemical injection system. The relay output shall turn on when the station reaches a minimum flow set point and turn off when station flow drops below set point. The minimum flow set point shall be adjustable through the touchscreen display where provided. 720-0000003 Chemical Treatment Relay • A Chemical Treatment relay shall be provided to activate a customer provided chemical injection system. The relay output shall turn on anytime a main pump is running. The chemical treatment relay shall have 2 DPDT 8A contacts. 750-0000003 Electrical Enclosure - 75x48x16 STL/WHT • A heavy duty industrial grade 75Hx48Wx16D UL Listed NEMA 4 outdoor rated enclosure shall be provided to protect electrical control system components. The enclosure shall be custom built to Watertronics specifications specifically for water pumping applications and shall be fabricated of no less than 12GA carbon steel finished on all inside and outside surfaces in polyester based WHITE powder coat finish for maximum durability. The enclosure shall be provided with heavy duty integral hinges with lift off doors INTERIOR LIGHTING PACKAGE heavy duty key lockable door handles continuously welded seams mechanical interlocks and drip shield. The electrical component back panel shall be galvanized steel for superior EMC performance. 760-0000008 Control Panel Leg Kit - 6"H x 16"D FosterGolfLinks 260604Q7 7 of 13 14 • A 6" HIGH heavy duty control panel leg kit shall be provided. Legs shall be fabricated from 3/8" thick A36 hot rolled steel plate and painted to match control panel enclosure color. The leg kit shall be designed for a 16" DEEP enclosure 770-0000010 Heat Exchanger - N4X Stainless Steel - (3350 Btu) 975-0000001 • A premium quality closed loop water -to -air HEAT EXCHANGER cooling system shall be provided. The heat exchanger shall be rated NEMA 4 with gray powder coated aluminum enclosure. Internal cooling coils and input/output connections shall be constructed of 304 stainless steel for superior corrosion resistance. The heat exchanger shall control temperature levels within the electrical enclosure, protecting sensitive electronic components from overheating conditions. The heat exchanger shall prevent outside air or cooling water from entering electrical enclosure. The heat exchanger shall be properly sized to the application up to 3350 Btu cooling capacity. Max water pressure 100PSI. Operation & Maint Manual (English) - Electronic Copy 3 • A detailed OPERATION and MAINTENANCE manual shall be provided detailing basic system operation alarms general maintenance procedures and use of the operator interface. The manual shall be in English and provided in electronic format. FosterGolfLinks 260604Q7 8 of 13 15 PUMP STATION PRICE (INCLUDES ALL STANDARD EQUIPMENT FEATURES) U.S. Dollars Only $219,450.00 Domestic US Freight from Factory to Job Site: FOB Factory Off Load & Setup Supervision: Crane To Off -Load and Set Pump Station: Start -Up: Warranty - (Including Parts and Labor) Taxes : Shipment:Estimated 12-14weeks after receipt of signed contract and drawing approval. A firm delivery date will be established and transmitted within 5 days of receipt of all final details and documents. WIRE TRANSFER: INCLUDED NOT INCLUDED NOT INCLUDED INCLUDED 2 YR STANDARD NOT INCLUDED 1 WARNING regarding wiring of funds: Due to the growing occurrence of identity theft and phishing scams, please do not wire funds to Watertronics without first receiving a verbal confirmation of our receiving bank's wiring instructions. Upon receiving wiring instructions from Watertronics, please contact John Bizub with Watertronics at +1-262-367-5000 x1203 prior to initiating any wire transfer to confirm the instructions match. Once the wire transfer is complete, please contact John Bizub again to obtain verbal confirmation of the transfer as well. Watertronics is not responsible for any funds that are unintentionally wired to the wrong recipient, regardless of cause. OPTIONAL EQUIPMENT FEATURES: (NOT Included in Total Station Price) (Indicate acceptance of a Optional Feature and Ext. Price by initialing ACCEPTED box next to each option being added to purchase)(Ext. Price does NOT include Taxes) OPTION NO DESCRIPTION QTY Price Ext.Price Accepted 780-0000003 Station Heater - 5KW - 480V 1 $5,188.00 $5,188.00 • An arm mounted 5KW - 480V industrial forced air heater shall be provided. The unit shall include an integrated 40 - 120F temperature control thermostat. A separate disconnect and branch circuit protection shall be provided that will allow the heater power to be controlled independently of the station main electrical panel. FosterGolfLi n ks_260604Q7 16 9 of 13 TERMS AND CONDITION DELIVER AND SETUP 1 All reasonable efforts will be made to meet the requested delivery date after the receipt of a signed contract however; Watertronics will not be liable for delays in delivery. 2 Pump station components shipped separately from the station, at the Customer's request, may incur additional freight charges, payable by the Customer. 3 Customer will be responsible for having job site readily accessible for station delivery via flatbed truck. 4 Customer will provide the equipment and personnel required to unload and/or set the pump station. 5 DOMESTIC (USA): Station Set-up charges include one day on site. If more than one day is required, additional charges of $950.00 per day will be assessed if the customer caused the delay. Travel time not included if separate service call is required. INTERNATIONAL DESTINATIONS: It is the responsibility of the owner's representative (contractor) to offload the station, identify any freight damage, inventory equipment and place the skid in position on the concrete slab. Vertical Turbines may be set in place on the skid for final assembly by an authorized service agent at time of technical startup. Any delays when on site due to events out of our control may incur additional charges. Charges include technician's time ($950/day), travel fees, airline penalties, hotel, and meals. FREIGHT DAMAGE must be written on shipping documents with copies going to the carrier and Watertronics. Watertronics will require pictures of damage caused by the carrier. MISSING EQUIPMENT from the Bill of Materials (BOM) must be identified within 2 weeks of delivery. 6 Customer will be responsible for electrical permit if required. 7 Customer will be responsible for primary electrical hookup to pump station. 8 Customer will be responsible for making all piping connections. 9 Customer will be responsible for building modifications (roof removal & installation) if required. 10 Customer will be responsible for wet well, slab, and concrete work. 11 Customer will be responsible for piping wye strainer / filter flush line back to supply lake. START-UP 1 Customer is responsible to guarantee the following before station calibration can be performed: a.) Permanent utility power is available and installed on pump station disconnect, b.) adequate water supply to operate station to full capacity, c.) installed irrigation system to operate station to full capacity. DOMESTIC (USA): Start-up charges include one day on site. If more than one day is required, additional charges of $950.00 per day will be assessed if the customer caused the delay. INTERNATIONAL DESTINATIONS: Final assembly and startup will be completed under the terms listed above. If the site is ready for startup i.e. power in place, site and infrastructure ready to run water the time allotted is adequate. Any delays due to events out of our control may incur additional charges. Charges include technician's time ($950/day), travel fees, airline penalties, hotel, and meals. 2 Purchaser will notify Watertronics two weeks in advance of the desired start-up date. POWER SUPPLY 1 The pump station proposed herein is designed for 480/277 volt, WYE configured 3 phase power. The acceptable range of voltage is 455 volts (min) — 495 volts (max). Unless specifically stated under Optional Equipment, open delta, phase converter, or other forms of unbalanced three phase power are not acceptable. 2 If the supply voltage is not within this acceptable range, the purchaser is responsible for making the necessary corrections. This may include re -tapping or replacing the primary transformer. If the supply voltage is outside the stated range, electrical components such as VFD's, fuses, breakers, overloads, motors, power supplies may intermittently trip or prematurely fail and will not be considered for warranty coverage. 3 The use of generator power is not recommended. If a generator is required as a temporary power supply, the pump station will be covered under Watertronics' limited warranty provided that their "Engine Driven Generator Power Warranty Policy and Operation Guidelines" document is strictly adhered to. 4 Proper electrical grounding of the pump station is a requirement. Station will not operate properly and could pose a health hazard if not properly grounded. Failures of any magnitude due to improper grounding will not be covered under warranty. FosterGolfLinks 260604Q7 10 of 13 17 WARRANTY 1 Watertronics warrants its pump station products to be free of defects in materials and workmanship for a period of two (2) years from the date of startup, but not later than twenty seven (27) months from the date of invoice, unless modified by customer with the selection of the extended warranty option. Stations deemed delivery complete and invoiced accordingly, at Watertronics' factory and stored there, shall have the warranty period commence as of the invoice date. Should the system require storage before startup after leaving the Watertronics' facility, the system must be stored in a secured, climate controlled environment that will not allow for degradation of the system due to moisture, extreme temperature variations, or human negligence. 2 This warranty is limited to replacing or repairing any defective component supplied by Watertronics at Watertronics' sole discretion and does not apply to equipment that has been damaged, misapplied or has been modified in any way. 3 Any work performed on the pump station must be provided by a Watertronics recognized PSN (Pump Service Network) service provider and documentation of all work performed within the warranty period must be on file at the factory. Any maintenance or repairs done without the pre -authorization of Watertronics, or its recognized service providers shall void this warranty. 4 This warranty does not cover damages under the following conditions, unless otherwise specified in writing: (1) Misapplied or inappropriate incoming power, improper grounding, vandalism, or any incidental damage, consequential damage, or act of God, (2) repairs or replacements made without the pre -authorization of Watertronics, or its recognized service providers,(3) exposure to destructive gaseous or chemical solutions, (4) exposure to water pH levels of less than 6.0 which is typically the result of SO2 burner or sulfuric acid injection, (5) water salinity levels greater than 2000 parts per million, (6) water from a reverse osmosis process plant, (7) unusually high dirt load or abrasives in the water, or (8) pumping water not suitable for turf irrigation. 5 Watertronics will not accept liability for any costs associated with the removal or replacement of equipment in difficult to access locations. This includes, but is not limited to, the use of cranes larger than 15 tons, scuba divers, barges, helicopters, or other unusual means. These extraordinary costs shall be borne by the owner, regardless of the reason necessitating removal of the product from service. 6 THIS WARRANTY IS ABSOLUTELY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTIES. THIS INCLUDES ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND OF ANY OTHER OBLIGATION ON THE PART OF WATERTRONICS. NO AGENT, EMPLOYEE OR REPRESENTATIVE OF WATERTRONICS HAS ANY AUTHORITY TO BIND WATERTRONICS TO AN AFFIRMATION, REPRESENTATION OR WARRANTY CONCERNING THE PRODUCT SOLD UNDER THIS WARRANTY. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. PAYMENT TERMS (U.S. DOLLARS ONLY) 1 All purchase orders are subject to acceptance at factory in Hartland, Wisconsin. Receipt of Production deposit, verification of acceptable credit and confirmation of order are required before production. On domestic orders of $100,000 or less, a 25% production deposit is required to initiate the order with the balance due net 30 days from date of final invoice. Orders over $100,000 require a 50% production deposit. 2 Late fee of 1.5% per month will be added to any balance due after thirty (30) days from the date of invoice. All payments and/or credits are applied to the outstanding balance before computing a finance charge. 3 In the event the customer cannot take delivery on the requested date, delivery shall be deemed completed, and the warranty period shall commence, at Watertronics' factory with storage for future shipment. For the purpose of payment, eighty (80) percent of the contract price will be due, payable net 30 days from invoice. The customer will be responsible for storage and handling charges at the factory. A minimum charge of $200 per week will apply, with total storage charges added to the final invoice. 4 WARNING regarding wiring of funds: Due to the growing occurrence of identity theft and phishing scams, please do not wire funds to Watertronics without first receiving a verbal confirmation of our receiving bank's wiring instructions. Upon receiving wiring instructions from Watertronics, please contact John Bizub with Watertronics at +1-262-367-5000 x1203 prior to initiating any wire transfer to confirm the instructions match. Once the wire transfer is complete, please contact John Bizub again to obtain verbal confirmation of the transfer as well. Watertronics is not responsible for any funds that are unintentionally wired to the wrong recipient, regardless of cause. FosterGolfLinks 260604Q7 11 of 13 18 OTHER INFORMATION 1 Prices valid for forty-five (45) days from the date of this proposal. 2 State and local sales taxes are not included in these prices. 3 Seller retains a security interest in the above mentioned equipment as provided by the UNIFORM COMMERCIAL CODE, until payment is received in full. 4 All claims for incorrect deliveries must be submitted in writing to Watertronics Customer Service within 15 days after receipt of goods. 5 All claims for price discrepancy must be submitted in writing to Watertronics Customer Service within 60 days after receipt of goods. 6 A completed pump station may not be returned to Watertronics for credit. CHANGE ORDERS 1. Change Orders initiated by parties outside of Watertronics, after an order has been entered, may require additional charges to the purchaser regardless of the reason or initiating party. A minimum administrative fee of $ 150.00 will be charged. a. Lost engineering and order administration time will be charged to the purchaser at $150.00 per hour. b. Purchase orders to vendors perfected by Watertronics made invalid by the Change Order will incur charges against the purchaser equal to any penalties levied against Watertronics. To include, re -stocking charges, lost freight charges or return goods freight charges and any vendor administrative costs. c. Watertronics lost manufacturing time will be charged to the purchaser at $100.00 per hour. Additional labor to satisfy the Change Order will be estimated at $100.00 per hour and added to the total Change Order amount. d. Materials made unusable or scrapped because of the Change Order will be changed to the purchaser at actual sale value as originally assigned to the job. Replacement materials or goods will be valued as required by the Change Order and be shown in its total. ACCEPTANCE 1 Purchaser hereby agrees that in the event of default in the payment of any amount due, that if this account is placed in the hands of an attorney, or agency for collection or legal action, to pay any and all related attorney fees, costs of collection including agency, private process servers fees, court costs, etc., incurred and any other costs of collection permitted by the laws governing these transactions. 2 Equipment cancelled before completion will incur restocking charges that will be calculated at time of cancellation. Restocking fees may be the full cost of the pump station depending on the nature of the pump station that is cancelled 3 Terms are subject to final credit approval. 4 Equipment shipped separately from the station, at Purchaser's request, may incur additional freight charges, payable by Purchaser. 5 Delayed deliveries by the customer once equipment is ready to ship, will incur minimum storage charges of $200 per week, added to the final invoice. FosterGolfLinks 260604Q7 12 of 13 19 EQUIPMENT PER QUOTATION: FosterGolfLinks260604Q7 Accepted BY Company Name : BY : Print Name: Title: Signature Date: Requested Delivery Date : Is this sale taxable? (circle one) Yes No (If the order is non-taxable, a tax certificate for the "ship to state must be submitted with this order" Please Return One Signed Copy of This Quotation On Acceptance. Merchandise delivered or shipped is due and payable to: Watertronics LLC, 525 Industrial Drive, P.O. Box 530, Hartland, WI 53029-0530. Phone 262-367-5000. BILL TO INFORMATION Company Name: Phone Email Address: Address City State ZipCode Contact Name (Print): SHIP TO INFORMATION Title: Company Name: Phone Email Address: Address City State ZipCode Contact Name (Print): Title: Thank you for the opportunity to quote on your pump station needs, If you have any questions or require further information, please call us at 262-367-5000. FosterGolfLinks 260604Q7 13 of 13 20 DESIGN SPECIFICATIONS MODEL #: VTV-7C-40X2/5ST-480-3-1000-90 STATION COMPONENTS ITEM # DESCRIPTION STATION PERFORMANCE: 1000 GPM @ 90 PSI MAIN PUMP: 40 HP (QTY. 2) JOCKEY PUMP: SUSTAIN PUMP:5 HP POWER REQUIREMENTS: 480V, 3 PH, 60HZ, 103 FLA EXHAUST FAN REQUIREMENTS: 1360 CFM LIFTING WEIGHT: PIPE COATING: EXTERNAL - Green INTERNAL - DISCONNECT SIZE: 200A 1 40HP MAIN PUMP AND MOTOR 2 5HP SUSTAIN PUMP 3 CHECK VALVE 4 PUMP DISCHARGE ISO VALVE W/ EBV 5 PRESSURE TRANSDUCER W/ GAUGE 6 6" FLOW SENSOR 7 3" PRESSURE RELIEF VALVE 8 8" STATION DISCHARGE ISO VALVE 9 CONTROL CABINET 10 NOREN HEAT EXCHANGER 11 VAF V1000-8" W/ 300 MIC SCREEN 12 3-3/4" TOL 13 DRAIN 14 PAINTED STEEL BASE 15 WET WELL HATCH 16 LEVEL SENSOR 17 SCS FLUSH LINE ADDITIONAL ITEMS: - MECHANICAL SEALS - WATERVISION 2.0 ISOMETRIC VIEW Revision Table XXX XX/XX/XXXX XXX XXX XX/XX/XXXX REV DRAWN BY DATE DESCRIPTION CHECKED BY DATE ❑ APPROVED AS SUBMITTED ❑ APPROVED AS NOTED ❑ REVISE AND RESUBMIT REVIEWD BY: NAME: DATE: DIMENSIONS AND SIZES OF EXISTING STRUCTURES, AND/OR COMPONENTS MUST BE VERIFIED TO WATERTRONICS BEFORE STATION CONSTRUCTION BEGINS. UNLESS SPECIFIED BY THE CUSTOMER, PUMP HOUSE/CONCRETE SLAB DIMENSIONS ARE RECOMMENDED MINIMUMS FOR NEC AND SERVICE CLEARANCE, AND ARE FOR ILLUSTRATION PURPOSES ONLY. PROJECT MANAGER SHALL BE CONSULTED ON FINAL DESIGN. THE PUMP STATION PROPOSED HEREIN IS DESIGNED TO BE PLACED IN A PUMP HOUSE FOR PROTECTION FROM THE ENVIRONMENT. IF A PUMP HOUSE IS NOT USED, WATERTRONICS MUST BE NOTIFIED AT TIME OF QUOTATION SO SPECIAL PROVISIONS CAN BE MADE. THIS DRAWING AND DESIGN, IS THE PROPERTY OF WATERTRONICS AND IS NOT TO BE REPRODUCED IN WHOLE OR PART, NOR EMPLOYED FOR ANY PURPOSE OTHER THAN SPECIFICALLY PERMITTED IN WRITING BY WATERTRONICS, THIS DRAWING LOANED AND SUBJECT TO RETURN ON DEMAND FOSTER GOLF LINKS VTV-7C-40X2/5ST-480-3-1000-90 DRAWN BY:PAN DATE:03/11/2024 CHECK BY: DATE: SIZE: A SCALE: 1:48 DWG NO. PRVT13329 REV: 1 PAGE: 1 011 117" 74„ INSIDE BASE BUILDING 22 176" INSIDE BUILDING 80" BASE 12 X42"ALUM WET WELL COVER 382" PLAN VIEW THIS DRAWING AND DESIGN, IS THE PROPERTY OF WATERTRONICS AND IS NOT TO BE REPRODUCED IN WHOLE OR PART, NOR EMPLOYED FOR ANY PURPOSE OTHER THAN SPECIFICALLY PERMITTED IN WRITING BY WATERTRONICS, THIS DRAWING LOANED AND SUBJECT TO RETURN ON DEMAND FOSTER GOLF LINKS VTV-7C-40X2/5S1-480-3-1000-90 DRAWN BY: PAN DATE:03/1 1 /2024 CHECK BY: DATE: SIZE: SCALE: DWG NO. REV: PAGE: A 1:32 PRVT13329 1 2 OF 4 68" BASE 212" WET WELL DEPTH 1 1 5" SUBMERSIBLE 060" WET WELL NW- 1 1" TURBINE 16" MAINLINE DISCHARGE 56" MIN WATER LEVEL ELEVATION VIEW THIS DRAWING AND DESIGN, IS THE PROPERTY OF WATERTRONICS AND IS NOT TO BE REPRODUCED IN WHOLE OR PART, NOR EMPLOYED FOR ANY PURPOSE OTHER THAN SPECIFICALLY PERMITTED IN WRITING BY WATERTRONICS, THIS DRAWING LOANED AND SUBJECT TO RETURN ON DEMAND FOSTER GOLF LINKS VTV-7C-40X2/5ST-480-3-1000-90 DRAWN BY: PAN DATE:03/1 1 /2024 CHECK BY: DATE: SIZE: SCALE: DWG NO. REV: PAGE: A 1:42 PRVT13329 1 3 C234 (18" ) 117 B74" ASE 7 25" 7 24 176" 80" BASE 332" / C i 11" 582" 8 FLG 16" 382" 68" 7 SLAB VIEW THIS DRAWING AND DESIGN, IS THE PROPERTY OF WATERTRONICS AND IS NOT TO BE REPRODUCED IN WHOLE OR PART, NOR EMPLOYED FOR ANY PURPOSE OTHER THAN SPECIFICALLY PERMITTED IN WRITING BY WATERTRONICS, THIS DRAWING LOANED AND SUBJECT TO RETURN ON DEMAND FOSTER GOLF LINKS VTV-7C-40X2/5S1-480-3-1000-90 DRAWN BY: PAN DATE: 03/11/2024 CHECK BY: DATE: SIZE: SCALE: DWG NO. REV: PAGE: A 1:42 PRVT13329 1 4 OF 4