Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit B94-0102 - BOEING #21-05 - STORAGE RACKS
City of ThkW`1 (206) 431-3 670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 RACK STORAGE PERMIT Permit No: B94 -0102 Type: B -RACK Category: Address: 3417 S 120 PL Location: PHASE B Parcel #: 102304 -9069 Zoning: M1 M2 CM Contractor License No.: BOEINC294ML Status: ISSUED Issued: 03/28/1994 Expires: 09/24/1994 Suite: TENANT BOEING #21 -05 3417 S 120 PL, SEATTLE, WA 98124 OWNER SABEY CORPORATION 201 ELLIOTT AVE. WEST, SUITE 400, SEATTLE WA 98119 CONTRACTOR BOEING INC. Phone: 206 544 -2975 9725 EAST MARGINAL WY S, SEATTLE, WA 981242207 CONTACT TERRY BENNETT. Phone: 206 544 -2975 P.O. BOX 3707 M/S 46 -87, SEATTLE, WA 98124 ******************************************** * * * * * * * * *** ** * *** * * ** * * ** * * ** ** Permit Description: INSTALL PALLET OR CANTILEVER RACKS. Rack Storage,Dimensions - Linear Feet. 580 UBC Edition: 1991 Valuation: 5,0.00.00 Height 10.0 .0 .0 .0 . 0 . 0 Total Permit Fee: Totals '5,800 5,800 62.50 ************ tk**.******************** �Ir******** * * * * * * * * * * * * * * * ** * * * * * * * * * * * ** Permit Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the sane to be true and correct. All provisions of law and ordinances governing th,is.work•will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or theHperformance .of work. I. am authorized to sign for and obtain this bui]1ii- rrg'perms . Signature: _�(l�fC.�� _ Date: Print Name: Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWIL4 Department of Co(... nunity Development — Permit Cent. , 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER PROJECT NAME 00-a.i n a. t-05 514 I 1 1Qo Pl SUITE NO. SITE ADDRESS , INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMENT TE :1 DATE PROVED QUIREMENTS'/ �OMtMAENT Ai BUILDING - initial review FIRE 3-1 b -y N 5\ (s) q4; 1L OUTED 11(1- "12�c�,��/i INIT: CONSULTANT: Date Sent Date Approved - FIRE PROTECTION: • Sprinklers FIRE DEPT. LETTER DATED: -))17,-3 N/A INSPECTOR: O PLANNING ZONING: INIT: REFERENCE FILE NOS.: BAR/LAND USE CONDITIONS? ( Yes MINIMUM SETBACKS: N- S- E- O PUBLIC WORKS UTILITY PERMITS REQUIRED? 0 Yes N INIT: PUBLIC WORKS LETTER DATED: O OTHER INIT. BUILDING - final review "R BUILDING OFFICIAL �J REVIEW COMPLETED TYPE OF CONSTRUCTION: ?''4144 n INIT: ,C-1 1`-'`� n C /q(1 INIT: INIT: CERT. OF OCCUPANCY? OYes I2 No UBC EDITION (year): Iq AMOUNT OWING: (� lc0.5b CONTACTED ,jam r � l 3 l,, _ , v-Q Y BY: DATE NOTIFIED , 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) 01/08/93 BUILDUIa PERMIT APPLICATION CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BURKS JOB # 147008 -00 PHASE B PLAN CHECK NUMBER APPL•ICATIO MUST BE .F /LL.ED OUT _COMPLETELY. DESCRIPTION AMOUNT RCPT # DATE BUILDING PERMIT FEE 5%.00 BUILDING USE (office, warehouse, etc.) WAREHOUSE NATURE OF BUSINESS: _AIRPLANES PLAN CHECK FEE WILL THERE BE A CHANGE IN USE? ] No 0 Yes If Yes, new building SQUARE FOOTAGE - Building: 209,446 Tenant Space: Area of Construction: 500 OR HAZARDOUS MATERIALS IN THE BUILDING? S stem BUILDING SURCHARGE it ,n(7 OTHER: TOTAL - (DO, €jc SITE ADDRESS SUITE # 3417 SO 120 TH PL BLDu. #21 -05 VALUE OF CONSTRUCTION - $ 5,000.00 _ PROJECT NAME/TENANT BOEING DEFENSE AND SPACE GROUP ASSESSOR ACCOUNT # 102304 -9069 TYPE OF ❑ New Building D Addition Li Tenant Improvement (commercial) U Demolition (building) WORK: Rack Storage [) Reroof O Remodel (residential) 0 Other DESCRIBE WORK TO BE DONE: INSTALL PALLET OR (ANT 'LEVER RACKS BUILDING USE (office, warehouse, etc.) WAREHOUSE NATURE OF BUSINESS: _AIRPLANES requirements may need to be met. Please explain: WILL THERE BE A CHANGE IN USE? ] No 0 Yes If Yes, new building SQUARE FOOTAGE - Building: 209,446 Tenant Space: Area of Construction: 500 OR HAZARDOUS MATERIALS IN THE BUILDING? S stem WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE () No [) Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: D S•rinklers gAutomatic Fire Alarm PROPERTY OWNER BOE INS; DEFENSE AND SPACE GROUP PHONE ADDRESS P.O. BOX 3707 M/S 46 -87 SEATTLE, WA. PHONE ZIP 98124 -2207 CONTRACTOR SAME ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # BOEINC -294ML EXP. DATE JAN 01 -1995 PHONE ARCHITECT ADDRESS ZIP I HEREBY: CERTIFY. THAT.I HAVE READ AND EXAMINED THIS; APPLICATION AND KNOW THE SAME TO!;:: BE TRUE AND CORRECT, AND;I AM'AUTHORIZ • SIGNATURE //° DATE BUILDING OWNER OR AUTHORIZED AGENT PRINT NAME TERRY BENNETT CONTACT PERSON ADDRESS PO BOX 3707 M/S 46 -87 TERRY BENNETT SEATTLE, WA. MARCH 15,1994 PHONE 544 -2975 CITY/ZIP 98124 -2207 PHONE 544 -2975 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED J-1 (0-61Lf DATE APPLICATION EXPIRES -1(o -961 10/22/93 CITY OF TUKWILA Address7 3417 S 120 PL Suite :' Tenant: BOEING #21 -05 Type: B -RACK Parcel #: 102304 -9069 Permit No 894 -0102 Status: ISSUED Applied: 03/16/1994 Issued: 03/28/1994 **• k********************• kk*** k***• k* ** * * *k*-k *-k*•kk* * *k*k * * * *kkh * * *k*•kk•k*•k **•k* Permit Conditions: 1. No changes will be made ythe 'plans,'`unIes$,,.approved by the Architect and the Tui(4 4:4 Building DiVisio.n. .- ' =,re,Y 2 A 11 p a -m i t s, insp.e.*01.on ' r esor fds�, andw approve' plans shall be maintained av ,l 1`ab l e at tihe, J,ob` side" priori. to the start of J' r kn• any constructson These docunie:n.ts are to be maint "'aion'e, available �t 1' fllnai ,i.,nspection appr ova r #gr a :.'`'_ o' '�i's�. r ted 3 All cons t,,,!2.. ct i .L s'� .� r12 t on tb kite do a 4,1W. confo -bance vii iafika"ppro V �:;° plans arts'1req, sire tints of theL�UtAi.forni Buis � "il N ,m 1''d ng Gaffe, '5.19:1 Edition):�;,as amended by the t&S.ii`i'nton State Eft/>i 10 n''§ °Cod&. ', 4. Val i di• . �iof Permit.,,, The i� ,'uance of'�a permit or,,� a�pprOva�1 'or''. ' ii p1anstr, speciyficat,ions ,ahJd;`•c'omputattoils shat 1 not' cos)- �. strue•d to b..,e a permit rfof�, or *� a,n- ,approval of, any' °viola,t�i'on` of ari:y, o fo r t `. }e; �_ s_ • q-,,,,,, :, !�. pt•ovision of t fi,� coda or of any otYier ,,; ordi,n.enc'e oil the ,jurisiii`c't.i:or). No .p..ermit presuming tto g<i,vve autj o sty ors violate .'o�Y•'-''.:04 'i °si,o.ns of this code sh l be valid ?. ' f a.� / , 'g ;A'^ t,'; .,"7.9' • * ******************* k* k*• frh**** k* ******h**** ************k** ** *** CITY OF T•UKWIL.A, WA TRANSMIT ****** ** **k******** ****** ********* ** ***•* ***•k* *k** ****h***Jr** *** TRANSMIT Number: 94000353 Amount: 62.50 03/28/94 08 :12 Permit No: 094 -0102 Type D -RACI( RACK STORAGE PERMIT Parcel No; 102304 -9069 Site Address: 3417 13 120 PL Location: PHASE 0 Payment Method: CASH Notations BOEING Init: SLD ***• k* 11***************** i1******•*•**** * * * ** * ** * * * * * * * ***i ** *•n * *1r *** 03/28/94 Account Code 000/322.100 000 /386.904 Description BUILDING - NONRE8 STATE BUILDING SURCHARGE Total (This Payment): Total Fees :. Total All Payments: Balance 62.50 62.50 .00 Paid 58.00 4.50 62.50 GENERA GENERA TOTAL CASH CHANGE 0486A000 58.00 4.50 62.50 62.50 0.00 16 :37 1 INSPECTION RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 • ro ect: , c® ,� tC9 r � + YPe o spa.. • n. �cl r Addre � 7 Date Called: ... Special Instructions: Date Wanted; "2.�"%771ra . p.m. Requester: Phone No.: Approved per applicable codes. .. Corrections raqu, ., . • rior to approval. COMMENTS: Inspector: Date: ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. j Receipt No.: Date: • ' 1 - INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 r• M. -�� i�o IN•:M • f r f Q - less: 7 � I ad r j t Date Called: Spacial Insttuci ons: Date Wanted: , r ,. �.�'.., l `� am. Requester v'•.u( phone No.: 99 f ' 37 D it f4Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Q - T /o c.-II p ? 1'S kefe.f.. e.,0-7 ,--,'(.1,s 6 q- , v'•.u( • ,S it / S d I.J.. *U0, s ,q . .rr / illy 0 $30.00 REINSPECTION rE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Date: •t_. L..Ran.:1it/ 444 444 MYi! Mt....7 Ya. AZA..i 4,"v•�ktti�,`3XS;i:' iii' �S' iw' ii, V`; q,, r ;;r��,�,1iS��.f,A,T�:.r1,...�:y ,y,v ",••,' ii' i'` i' �fb''' tlZiSA' �4' i-/ '.4 ^A*r�,.�%..fr.,•.;4�+¢iij�.� l,l c City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Gary L. VanDusen, Mayor 1 Control No. 43%Y` O /02 U// Permit No. Project Name %`Y ).A?r l! "Fr/e/i-d,L1r _tx a 1—�S ,4' Address ,.50 ,,r /1 /7t2 j- ,-/ Suite # Retain current inspection schedule X Needs shift inspection • X Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: rC uhoriaed Sign� r at FINALAPP.FRM A/94 Date T.F.D. Form F.P. 85 CITY OF TUKWILA RACK STORAGE DIMENSIONS LINEAR FEET X HEIGHT = TOTAL x x x x x 10 = es 00 11110•10•11 .111M■ .•••• PIENS. 4.11.11 11■•••• ••••1111 VaMENIO GRAND TOTAL = GBct) RECEIVED CITY OF TUKWILA MAR 6 1994 PERMIT CENTER 18" 120" _ 106" 1/2" DIA A. BOLT W/ 2 1/4" MIN. EMBED. 54" CANTILEVER RACK SCALE: N.T.S FLOOR (REF) GENERAL Ni : f ES. 2" 4" rue BASEPLATE DETAIL SCALE: N.T.S. CITY OF TUKWI A APPROVED MAR 2 5 199k S -1 B LDl G DIVISION INSTALL X— BRACIi1G IN EVERY BAY. USE 1/2 "DIA RODS. PER MANUFACTURER 2. ANCHOR RACK TO FLOOR AT EVERY BASE AS SHOWN IN DETAIL A. 3. INSTAL LOAD LIMIT SIGNS " MAXIMUM LOAD 1000 LBS PER ARM." 4. SEE ARCHITECTURAL DWGS. FOR LOCATION OF RACK. RECEIVED CITY OF TUKW1LA MAR 1.6 1994 PERMIT CENTER BY: r.., BURKS ECKED BY: 2/24/94 APPROVED 6Y: G41 CANTILEVER RACK 21 -05 D.C. PRoLcT No. 147008 APPROVED L v mo. .c No. SK72B940224 9W —i L 18" 120" 106" 1/2" DIA. A. BOLT W/ 2 1/4" MIN. EMBED. 54" CANTILEVER RACK SCALE: N.T.S FLOOR (REF) GENERAL NOTES. BASEPLATE DETAIL A SCALE: N.T.S. CITY OF TUK'JILA APPROVED MAR 2 5 1994 Bt-DING DIVISION S -1 INSTALL X- BRACT ? EG IN EVERY BAY. USE 1/2 "DIA RODS. PER MANUFACTURER 2. ANCHOR RACK TO FLOOR AT EVERY BASE AS SHOWN IN DETAIL A. 3. INSTAL LOAD LIMIT SIGNS " MAXIMUM LOAD 1000 LBS PER ARM." 4. SEE ARCHITECTURAL DWGS. FOR LOCATION OF RACK. CANTILEVER RACK D.C. RECEIVEr CITY OF TUKI MAR 1 6 PERMIT CO P*OZCT NO. 1470 SK72B9 9CET Na. s BOEING MILITARY AIRPLANES BOEING DEFENSE & SPACE GROUP 21 -05 BUILDING DEVELOPMENTAL CENTER STRUCTURAL CALCULATIONS FOR CANTILEVER RACK INSTALLATION JOB #147008 RELOCATE BLANKET SHOP FEBRUARY 23, 1994 JON R. BURKS CV 0 �t� pPP t3 �JE Q MAR 2 5 1994 uivisy.. THE BOEING COMPANY DEVELOPMENTAL CENTER SEATTLE, WASHINGTON APPROVAL * *qui MCKINNEY RECEIVED CITY OF TUKWILA MAR 1 6 1994 PERMIT CENTER /l C7-1"cs -- -v b-7'- /999 el.,e V4 invz- � o S,/A -s ©r- C fi9AI7 " 7/5 6`1\177Le/ '/ rts,a 7-1-/75 .Jo2 \ewir' frIV Y' //V 77& .5474 49 M,4'NM/ P 4iv.J iO,),Vp 1v 8E gpEQvy-i ', 71yfi .s ue / Y ToL_ 7vg/v/A/5 // 6.7 >i, /17/G, iz $D L7S CfYLY P,2G \leNT SG /p//; (5, 5/136 5e-5.-/1-12= r �� 7 " 4, h7/ `r vv/ ?//� " 2 l� ��?c��' -; off, P !e4 �. (/$6 (z) . "(� ,4. goc. T w7 241' mu , / eRG4 TVD c 7 2- uGTz211.*L.. ENGR. J a , 2/25 REVISED DATE 14-700 f `i`r`'' r1 I 6 e- 8LNKi 1. Silo tom, CK AIR AIR ; 14/94.. ANZEING CANTILEVER RACK DESIGN VERSION 1.0 BY JON BURKS JOB # DATE 147008 2/23/94 INPUT ARM ARM LL = ARM DL = FY arm = L arm = 1000 (lb) 50 (lb) 42 (ksi) 18 (in) IMPACT = 10 (o) L fact = 0.67 INPUT COLUMN # ARMS = 2 DL col = 300 (lb) Fy col = 42 (ksi) height = 120 (in) base wd = '44 (in) wd /col = 32 (in) �TRY.,:TYPE ,C..�y., UPRIGHT.a Ae = Sx Sy = 3.76 (in"2) 7.08 (in"3). 4.29 (in"3) LcPo cP5 4 Pgrii Gf° NT I L6V \AI I LOi-1 P or" L.Y 5 IC)(-:: LGorp P mot. r L.L• Mseis rx = ry = Klong = Ktrans = 2.74 (in) 1.51 (in) 1.00 2.00 INPUT DETERMINE BASE SHEAR V= ZICW /Rw Z = 0.30 I = 1 C = 2.75 W = 1.90 (k UPRGHT +ARM +75%LL) Rw = 5.00 V = 0.31 (k) LEVEL hx (in) Wx (k) Wxhx wxhk /Wxhx Fx Mot (k -in) 2 106 0.55 58.30 0.66 0.21 22.02 1 54 0.55 29.70 0.34 0.11 5.71 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 1.10 88.00 1.00 0.31 �2;7,A•k 3 ARM DESIGN M = 13.65 (k -in) (LL +IMP *LFACT *L +DL *L /2) Sreq = 0.54 (in"3) (M /Fy *1.67) Sx = Mn = Ma = 1.88 (INA3) 78.91 (k -in) (Mn= Sx *Fy) 47.25 (k -in) (Ma= Mn /1.67) ' Nla �,�`, :Md1 +11 •.;.Jo :�.TSEy��TYPE .rA •: CHECK ALLOWABLE LOAD IN COLUMN Fe = Fn = Pn = SF = Pa = 37.31 (ksi) (Fe = pi"2 *E /(K1 /r)"2) 30.18 (ksi) (Fn = Fy(1- Fy /4Fe))FN =FE IF FE <FY /2 113.47 (k) (Pn = Fn *Ae) 1.84 (5/3 +3 /8 *(Fy /2Fe)'.5- 1 /8(Fy /2Fe)''.3 61.51 (k) (Pa.= Pn /SF) CHECK BENDING IN COLUMN Mn = 297.36 (k -in) (Mn= Fy /Sx) Ma = 178.06 (k -in) (Ma= Mn/1.67) CHECK COMBINED STRESS (DL +LL) P = 2.30 (k) M = 27.30 (k -in) :M /Ma = '1.1SE `C ± 0.19 OK CHECK COMBINED STRESS (DL +LL +SEIS) < =1.33 Mseis = 27.73 (k -in) Md +1 = 27.30 (k -in) M = 55.03 (k -in) P = 2.30 (k) `?; ::,:SCI /Ma.= TR . 3 5 OK • vvsgEc DETERMINE OVERTURNING Movt = Mres = 27.73 (k -in) 46.40 (k -in) SFovt ;....., ":'.M:; :1.67 Ra = 0.42 (k) RIO ..0 ..nfiV r.yM • (k)'1 DETERMINE OVERTURNING TOP SHELF LOAD ONLY Movt = Mres = SFovt = Ra = Rb = 13.99 (k -in) 28.00 (k -in) 2.00 0.32 (k) 0.78 (k) CANTILEVER RACK DESIGN VERSION 1.0 BY JON BURKS JOB # 147008 DATE 2/23/94 INPUT ARM ARM LL = ARM DL = FY arm = L arm = IMPACT = L fact = 1000 (lb) 50 (lb) 42 (ksi) 18 (in) 10 ( %) 0.67 INPUT COLUMN # ARMS = 2 DL col = 300 (lb) Fy col = 42 (ksi) height = 120 (in) base wd = 44 (in) wd /col = 32 (in) TRY.: TYPE'.0 '::: = 'UPRIGHT Ae = 3.76 (in "2) Sx =, 7.08 (in "3) Sy = 4.29 (in"3) X042 C :f3 S #g_.? F rx = ry = Kiang = Ktrans = 2.74 (in) 1.51 (in) 1.00 2.00 INPUT DETERMINE BASE SHEAR V= ZICW /Rw Z = 0.30 I = 1 C = 2.75 W = 1.90 (k UPRGHT +ARM +75 %LL) Rw = 5.00 V = 0.31 (k) LEVEL hx (in) Wx (k) Wxhx wxhk /Wxhx Fx Mot (k -in) 2 106 0.55 58.30 0.66 0.21 22.02 1 54 0.55 29.70 0.34 0.11 5.71 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 0 1.10 88.00 1.00 0.31 ;L 7:73 �I j ^ CS' ,. ¢ f1 ARM DESIGN M = Sreq = 'TRY TYPE A Sx = Mn = Ma = 44,11,44:14?-4:" USE TYPE :A_CA 13.65 (k-in) (LL+IMP*LFACT*L+DL*L/2) 0.54 (inA3) (M/Fy*1.67) 1.88 (IN"3) 78.91 (k-in) (Mn=Sx*Fy) 47.25 (k-in) (Ma= Mn/1.67) CHECK ALLOWABLE LOAD IN COLUMN Fe = Fn = Pn = SF = Pa = 37.31 (ksi) 30.18 (ksi) 113.47 (k) 1.84 61.51 (k) CHECK BENDING IN COLUMN (Fe = piA2*E/(K1/r)A2) (Fn = Fy(1-Fy/4Fe))FN =FE IF FE<FY/2 (Pn = Fn*Ae) (5/3+3/8*(Fy/2Fe)A.5- 1/8(Fy/2Fe)A.3 (Pa = Pn/SF) Mn = 297.36 (k-in) (Mn=Fy/Sx) Ma = 178.06 (k-in) (Ma=Mn/1.67) CHECK COMBINED STRESS (DL+LL) P = 2.30 (k) (3) 16' K-iN 0 P/Pa-4.:M/Ma. 70;19 :OK (1;16 ;94PIANDA. 511'• /78'100(0 UPg A CHECK COMBINED STRESS (DL+LL+SEIS) <=1.33 Mseis = 27.73 (k- '.6141-C7 Md+1 0 M = KC; C P = 2.30 (k) (s) It- 5C, 176.00 . T/Eca'7.47.:4■Vmd.";=.i:.;.4 et. 6 DETERMINE OVERTURNING Movt = Mres = 27.73 (k-in) 46.40 (k-in) ,SFot-rtn;742Zg23.:46.1. Ra = 0.42 (k) Rb DETERMINE OVERTURNING TOP SHELF LOAD ONLY Movt = 13.99 (k-in) Mres = 28.00 (k-in) "ROMFAiiii00002A Ra = Rb = 0.32 (k) 0.78 (k) BOEING MILITARY AIRPLANES BOEING DEFENSE & SPACE GROUP 21 -04 BUILDING DEVELOPMENTAL CENTER STRUCTURAL CALCULATIONS FOR CANTILEVER RACK INSTALLATION JOB # 127017 -03 JULY 23, 1992 JON R.BURKS THE BOEING COMPANY DEVELOPMENTAL CENTER SEATTLE, WASHINGTON APPROVAL G& G. MCKINNE(Y J. CARRIe' EXPIRES 12 /11tGi'5 TI-H5 NA Ysrs T THE ST2vGT ✓��L pEQv/4.•cy of P r ME -r-1, G,4-1\/7" /LEVEE FpvR Lo Gib ES VVE c �'IJ'4 —'Y2 si NCI G5 S 1 ivc7 GE s-F2- Go" i� lul �3 " PO v31-5 AM PQY 3 r;5 M THE \A/ORS-r- L Co tI G F s E wE-i C 1:17T1c/, 7 1 1 + 7 7 / 4 - - 1 - 1 , /3 C H * /2 l I P /C?. l/ 4-7 <v!u_S THE E Q YetV C 4-S E W 11 V 77-1E; Wo,Rs-; r ni a m o Mr E// W s 17ETereI rJ FOP_ S' 1Z /ti/a ENGR, J aigKs REVISED DATE Gi' ^/i l L E VE l � R Ac -g V (� f� 1270 1.7 - 03 // I /4 / CHECK AIR APR .®OE/NG DETE m /NE Slag OF 4. SoLTs ' o RS "7' . f? 1.s w / 5/ N67LE B (477,4c/-/ MEN/. * 7) I4 ''T = 154,27 /4/. /`(1 l'!1 = to 7RY K f , (/4,z 7) - �f� I/ 2 ksoo • _.. llo /• 5,,, 7- �r}GK I/ " fy _r- /' c,,Oo I& 15 {` 2(f,5' • a T w - M/N EN6R. J , EuR, .0 7/2.2. REVISED DATE CHECK APR APL �r w. p�4ZAfiV material lmt rack arms horizontal brace x-brace 18' (216.0 ") /9G /73 i BAY 1 CANTLEVER RACKS 19.0" 19.0" 1 19.0" a 19.0" it 35 19.0" 19.0" 19.0" 19.0" r 16 19.0" 12.0" FLO-OR EACH CANTILEVER ARM IS. 5.0" WIDE SPACING DOES NOT INCULDE ARM WIDTH KEY A 1--12 B 1--12 D 1 -9 Di7 DG PIA/1 a 0 1 "�' secrro his • csi aciLE 4- CANTILEVER RACK DESIGN VERSION 1.0 BY JON BURKS JOB # 127017--03 DATE 7/21/92 INPUT ARM ARM LL = ARM DL FY arm L arm = IMPACT = L fact = 1000 (lb) 50 (lb) 42 (ksi) 60 (in) 10 ( %) 0.67 INPUT COLUMN # ARMS = 8 DL col = 300 (lb) Fy col = 42 (ksi) height = 216 (in) base wd = 72 (in) wd /col = 60 (in) TRY TYPE G UPRIGHT Ae = 6.97 (in-2) Sx = 16.92 (in-3) Sy = 8.36 (in-3) rx = ry = Klong = Ktrans = 3.99 (in) 1.55 (in) 1.00 2.00 INPUT DETERMINE BASE SHEAR V= ZICW /Rw Z = 0.30 I = 1 C = 2.75 W = 6.70 (k UPRGHT +ARM +75 %LL) Rw = 5.00 V = 1.11 (k) LEVEL hx (in) Wx (k) Wxhx wxhk /Wxhx Fx Not (k -in) 8 196 0.84 164.15 0.21 0.23 45.96 7 173 0.84 144.89 0.19 0.21 35.81 6 150 0.84 125.63 0.16 0.18 26.92 5 127 0.84 106.36 0.14 0.15 19.30 4 104 0.84 87.10 0.11 0.12 12.94 3 81 0.84 67.84 0.09 0.10 7.85 2 58 0.84 48.58 0.06 0.07 4.02 1 35 0.84 29.31 0.04 0.04 1.47 O 0 0.00 0.00 0.00 0.00 0.00 0 0 0.00 0.00 0.00 0.00 0.00 O 0 0.00 0.00 0.00 0.00 0.00 O 0 0.00 0.00 0.00 0.00 0.00 O 0 0.00 0.00 0.00 0.00 0.00 0 6.70 773.85 1.00 1.11 154.27 ARM DESIGN M = 45.50 (k -in) (LL +IMP *LFACT *L +DL *L /2) Sreq = 1.81 (in-3) (M /Fy *1.67) TRY TYPE A ARM Sx = 1.88 (IN "3) Mn = 78.91 (k -in) (Mn= Sx *Fy) Ma = 47.25 (k -in) (Ma= Mn /1.67) Ma > Md1 +11 OK USE TYPE A CHECK ALLOWABLE LOAD IN COLUMN Fe = Fn = Pn = SF = Pa = 14.73 (ksi) 12.05 (ksi) 83.97 (k) 1.97 42.54 (k) CHECK BENDING IN COLUMN (Fe = pi"2 *E /(K1 /r)"2) (Fn = Fy(1- Fy /4Fe)) (Pn = Fn *Ae) (5/3 +3 /8 *(Fy /2Fe)".5- 1 /8(Fy /2Fe)".3 (Pa = Pn /SF) Mn = Ma - 710.48 (k -in) (Mn= Fy /Sx) 425.44 (k -in) (Ma =Mn /1.67) CHECK COMBINED STRESS (DL +LL) P = 9.20 (k) M = 252.00 (k -in) P /Pa + M /Ma = 0.81 OK. USE G CHECK COMBINED STRESS (DL+LL+SEIS) < =1.33 Mseis = Md +1 = M = P 154.27 (k -in) 252.00 (k -in) 406.27 (k -in) 9.20 (k) P /Pa + M /Ma = 1.17 OK USE G DETERMINE OVERTURNING Movt = Mres = SFovt = 154.27 (k -in) 210.00 (k -in) 1.36 Ra = ,Rb= 0.77 (k)' 5.93 (k) DETERMINE OVERTURNING TOP SHELF LOAD ONLY Movt = Mies = SFovt = Ra = Rb = 25.87 (k -in) 42.00 (k -in) 1.62 0.22 (k) 0.88 (k) City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 John W. Rants, Mayor March 23, 1994 Fire Department Review Control #B94 -0102 (512) Re: Boeing Company Building #21 -05 - 3417 South 120th Place Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3303(d)) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material. or matter where its presence would obstruct or render the exit hazardous. (UFC 12.104(a)) When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 3314(A)) The color and design of lettering, arrows and other symbols on exit signs shall be in high contrast with their background. Words on the sign shall be block letters 6 inches in height with a stroke of not less than 3/4 inch. (UBC 3314(b)) Aisles leading to required exits shall be provided from all portions of buildings. The width and spacing of aisles shall be maintained at all times. (UFC 12.104(b)) City Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor 2. Storage may not be closer than 36 inches in all directions to ceiling -hung "Space or Unit" heaters. (UFC 11.404) Storage may not be closer than 18 inches below sprinkler heads. (NFPA 13, 4 -2.5 and NFPA 231.5 -1) To use any building or portion thereof exceeding 2,500 square feet for the storage of high -piled combustible stock. A floor plan showing the dimensions and location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 4.108(h3)) In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) Maintain minimum 6" longitudinal flue space between back to back racks. 3. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, 5(4- w The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd CITY OF TUKWILA Id: ROUT130 Keyword: UACT User: 1677 Activity document routing maintenance. RACK STORAGE PERMIT Permit No: B94 -0102 Tenant: BOEING ::;. #21 -05:. Status: PENDING Address: 3417 ` S . 120 PL Route: 1 Current Route Line: 3 of 6 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Packet Units Action Station Initials Status Received Assigned Completed RACK 01 01 C BLDG KEN Approved 03/16/94 03/18/94 03/18/94 Priority (0 /low..9 /high): 0 Regular hours (HH.MM): .00 Overtime Hours(HH.MM): Comments 1[RACK::EXIT: .':'.::.o;.,';O.K. ] 2[PHASE "B" ONLY ..._. ] 3[ 4 [FIRE PLEASE REVIEW ;:::AND ;,;.COMMENT. ] 03/18/94 6 [ DY; %;:;REN.- ] 8[ ] 9[ ] ] 10[ aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa 1 F1 =Help, ESC =Exit current screen. - DETACH TO DISPLAY CERTIFICATE —y ' , .y 4% -44 *0:44*- ....,F1V4V.WC '•'ic1�,• .- --GS..rii-..4V 4 - iii.:�r.;.i:::�;,:tF•r•.. -•K r C:ii.�.;r ,�, : !. �s�sss str .. r r r,!�!H�. �s _..__ �+s�±►wsr�r =��s� ••• •••�4srs x ,s nrasessh�a fr_a rassr as h a.f.** tnxeea,*ZSUri• ••.•' .• € DEPARTMENT OF LABOR AND INDUSTRIES i THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A CONST CONT GENERAL. REGISTRATION NUMOER EXPIRATION OATE • 01 BOEINC *294t`1L. 01 /01 /95 . EFFECTIVE DATE 07/1.3/71 BOEING COMPANY, THE P . 0 130X 3707 MAIL. STOP 1F -09 SEATTLE WA 981242207 STATE OF WASHINGTON . F625-052-000 V.K�Vi� u��u��.�u..uwV��u�. .WUW�uaua�u.�y�µ♦.�«Z�ST�i: .�`lt�uuu �:.::14!t._L.•sui`!t!l i i�� u1uL..�« L DETACH TO DISPLAY CFRTIFICATF 1 ti "..+1,LF t:tii?S q�. +ti �r� ". ,... N. r. ...rr•a h.c,(l,krwrxs.ti.'i 11 Y ��k approvals are . the pie, Cis» r rovat e itnderst�nd t� ions e app ytC118t1o+� .O #iriY` of SI ans does tg3 %OI tt%O t' p� coil,. �yaris r�aaa Nacre�P ada> ted ^.cad$; or ordi�a owted9�d: tractor's `GOo� of ap Vedi do ack 3LDG. 21 -05 ADDRESS 3417 S0. 17.0TH PLACE TUKWILLA, WA. (CAST NA�GINAL WAY CORPORATE PA34) REVIEWED AND STAMPED [3Y THOU. CONSTRUCTION SET OF DOCUMENTS, rGITY OF TUKiNILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. VERIFY ALL DIMENSIONS PRIOR TO START OF CONSTRUJCTION. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRED DESIGN REVISIONS. REVISIONS TO BE APPROVED BY CITY OF TUKWILA PRIOR TO PROCEEDING WITH PROPOSED 'REVISED WORI(. DWG. No... SHEET TITLE T!TLE EXISTING PLAN FENCE DETAILS CHECK BOX EXIT 158 157 -- INSTALL 7` HIGH SHOP FENCING, STORAGE. RACKS, ELECTRICAL, & MECHANICAL IMPROVEMENTS FOR THE INSTALLITION OF THE BIANkET SHOP THESE. DRAWINGS CONFORM TO ` THE 1991 tJ B.C,, 'U f .0 , U r.C., AND THE 1990 BARRIER FREE CObE AS AD PIED 'OR " AMEt DE►3 Y LOCAL ORDINANCES, ..• G COMD +FIANCE 1N1TH CITY OF TUKW1LA ZONtNC. COMPLETE BUILDING. FLOOR • PLAN SHOWING EXITING SYSTEM, DOORS, CORRIDORS • AND PASSAGEWAYS. G!N`EERiNG CALCULATIONS -IF APPLICABLE } C! ROOMS LABELED PER rOCCUPANCY PER U.B.C. TABLE 33 -A: a BUILDING FL ' OOR 'NUIAER ON PRINT FOR AREA OF.2. CONSTRi)0(ON. NUMB R' QF PRINT5' REO111 ED FOR PERMIT 'PACKAGE: P (SHELL_ • & *COI E) GENERAL PERMIT' 6 SETS OF ENERGY CALCULA °TIONS 2 SETS' OF ' LIVIL" ` RA WINGS W41TH UTI)1`lES 7 SETS SOILS REPORTS- STAMPED. BY GEOTECNICAL- ENGINEER 2 SETS STRUCTURAL CALCU,LATIO S 2 SETS PROJECT' CONST'RIICTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SIJRVE 2 COPES • OF. LEGAL DESCRIPTION • 1x F WORKING DRAWINGS c�SCSQ 1 2. TENANT' IMPROVEMENTS) 2 'COMPLETE SETS C7 3. MECHANICAL,, 2 COMPEEfC SE`fS 0 4. • FIRE PROTECTION /SPR NKLERS, 2 COMPLETE SETS l AND` USE CODE CODE' REFERENCES -� -�-. 91 UGC KING GUUN , Y f TUKW1LA •ASI4INGT'ON STATE •ENERGY 'CODE.. • WASNINGTOW STA:iE BARMIER`FEE `CODE ADDETIOIVS P CTY'`Os: TLkWELLA B .H2 OFFICE /WAREHOU.SE, NO CHANGE 1N `OCCUPANCY F'Il E 'PRt 'YECTiQNS SEISMIC`26NE FIRE ZONE r ---- PARKtNG PROVIDED PARKING 'REQUIRED ---- ' FULLY 'AUTOMATIC, WET I'IPE THRO CHQ T: 3 739 725 Ofrf OEF ,}"UKWitA P P>71T +C rr R • N ELEC`fRICAI PERMITS. ARF 1O EE : SUBMIT�T'ED SEPARA1tY FRC)Mr T II i - CKAS�E•. NOTE: > MECHANICAL.' A D E .. Q AUBURN, 'A. 98002 �.KENY, vA. 9803 DPORTL.Ah D,; OR: 97220 • L 1 RENTON, . WA. 9 SEATTL tP: ACC PYA iLIlY PHIS DESIGN AND /OR SPECIMA1ION IS APPROVED APPROVED BY SLID 1t . CHECKED BOG 21 -05.1 • 1111111111 0 10 TH31NCH rz 9Z 4Z tie 7 ce az 111111 i1 1111111.1011'4j 0lit� 1 x111 4 NOTE: 1t1 I 11 1 t I�'` •I ;1j' ..I . `1111111111111 111111111111111111 11111111111 10 11 w1oE N GFRwwr 124 1 t`WW 0 i I11�1 I I'111 nn I filnII Odd 11 `fil HInnlind .: �:.N w..--- r,!ir, +u S.-.:<: i,.:.. arr: c1+ i+.�.,•_Y.:i'A'i.Y.'..�.';_�-,- y....— :e,.:..'.:.,. 5 6 7 f the >sficrot�ilated document is leas clear than this notice, it is due to the quality of the original document. IZ ( Ft et 11 91 5I 'I £1 8t It OL 6 11.111 1 111 II k . - Off IiillCir�lilllll l r JCYr rI oNitie"rdi itiYr. °a CUPANT LOAD I.': ANS j i• i�lallal onnr;annntinoa `I f *. OCCUPANT M"' Wire MP* 111.1f0 ' -- �,.ww.- ..a.ww.- ....w. D AUBURNNJz WA. C EVERET �', ti�pdrA. (PO`�RT AND, FOR, EJ REN ! ON,, Y A. SEATTLE, WA. ACCEPTABtm( THIS DESDN AND /OR SPECIRCAtION IS APPROVED APPROYtD BY REC,£IVEI, CITY OF TUKWILj\ viAll 16i94'-, PERMIT CENTER LAST REYIRON S APPROVED APPROVED BLDG. 21-05.1 CORP. PARK •n 3 4 TNOTE: If the microfilmed document'is Less clear than this notice, it is due'tu the quality of the original document. 471 et zt tit OL 111111,11 111011 1111111 111,1011110, Ai:n&.tiPFim4vSpMLkY; "Y4fd�.i1 =; aix`s w9d iii 111111 11111111111j'111'1.1Ii111111 1'11111 10 11 mun¢aeERHN►rf 12" A9.r YaW9r.:QL.o D VICINITY MAP rmi FROM DOWNTOWN SEATTLE Ell mete - EXIT 157 99 FAST MMEQ L RAY ROM SEATTLE- TACOMA AIRPORT 599 TUKWILA FROM KENT & AUBURN PROJECT SITE DEVELOPMENTAL CENTER NO SCALE , NES 5, Cb 3 D BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILLA. WASHINGTON 98108 AREA MAP BLDG. 21 -05 ADDRESS 3417 SO. 120TH PLACE TUKWILLA, WA. (EAST MARGINAL WAY CORPORATE PARK) PROJECT SITE J NO SCALE EAST MARGINAL WAY CORPORATE PARK 0 GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. VERIFY ALL DIMENSIONS PRIOR TO START OF CONSTRUCTION. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRED DESIGN REVISIONS. REVISIONS TO BE APPROVED BY CITY OF TUKWILA PRIOR TO PROCEEDING WITH PROPOSED REVISED WORK. PROJECT CHECKLIST CHECK BOX • BRIEF PROJECT NARRATIVE . INSTALL 7 HIGH SHOP FENCING, STORAGE RACKS, ELECTRICAL & MECHANICAL IMPROVEMENTS FOR THE INSTALLITION OF THE BLANKET SHOP mit-ma • THESE DRAWINGS CONFORM TO THE 1991 U.B.C., U.F.C., U.P.C., AND THE 1990 BARRIER FREE CODE AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. • COMPLETE BUILDING FLOOR PLAN SHOWING EXITING SYSTEM, DOORS, CORRIDORS AND PASSAGEWAYS. • ENGINEERING CALCULATIONS ( IF APPLICABLE ) O ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 33 -A. O BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL ENGINEER 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS O 2. TENANT IMPROVEMENTS, 2 COMPLETE SETS O 3. MECHANICAL, 2 COMPLETE SETS O 4. FIRE PROTECTION/SPRINKLERS, 2 COMPLETE SETS Jir h OAR ROWS at AIAAOMIO OAR 1 SOS,ASQ FACILITIES DEPARTMENT EJ AUBURN, WA. • EVERETT, WA. p KENT, WA. ❑ PORTLAND, OR. O RENTON, WA. • SEATTLE, WA. 98002 98201 98031 97220 98055 98124 IIIIRCORATION 1111* SNAMAOY[O ;:;;. O s. son. OAR EA Kr sr- ., a . 1 u odor stIOS llwlM SSP pSW suOloott0 «r "' plans dose On *Own re *Woe eV o1 ,0^ adopted ogle at ot'dln�w• tractor's cord of av Dot• Permit No. • DRAWING INDEX te T D. No. SHEET TITLE SHEET D. No. SHEET TITLE , AI 21 -05 -A1 TITLE ~ 42 21 -05 -A2 EXISTING PLAN 43 21 -05- A3 FENCE DETAILS r WA Sig . IN a-x ._ , CODE SUMMARY LAND USE CODE CODE REFERENCES OCCUPANCY GROUP FLOOR AREA (ACTUAL) STORIES FIRE PROTECTIONS SEISMIC ZONE FIRE ZONE PARKING PROVIDED PARKING REQUIRED M HP 1991 UBC KING COUNTY / TUKWILA WASHINGTON STATE ENERGY CODE WASHINGTON STATE BARRIER FEE COOS ADDITIONS PER OTT OF TUKWILLA 8 2 OFFICE/WAREHOUSE, NO CHANGE IN OCCUPANCY BUILDING FOOTPRINT — 98,000 SF 1 FULLY AUTOMATIC, WET PIPE THROUGHOUT 3 3 739 725 COY PPROVEA AR 2 5 1994 L ED orninitA MAR 1 B 1994 PrAtIF eh, NOTE: MECHANICAL AND ELECTRICAL PERMITS ARE TO BE SUBMITTED SEPARATLY FROM -TEIP 440CAGE. ISION MVOS IMIOCO AAAAOS A/AOOY:1 TITLE SHEET BLDG 21 -05.1 ARCHITECTURAL MASTER D.C. �• a° 1410011-00 exiting floor plan