HomeMy WebLinkAboutPermit B94-0184 - HOVAIR - PAINT BOOTHCity of ?ictkwil `o1"(14 �— oM,�-n.ac�� (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B94 -0184 Type: B -BUILD Category: ACOM Address: 1210 ANDOVER PK E Location: Parcel #: 352304 -9075 Zoning: Type Const: N/A Gas /Elec: Wetlands: Water: TUKWILA Contractor License No.: WEZLYDC142B8 Status: ISSUED Issued: 06/15/1994 Expires: 12/12/1994 Suite: Type of Occupancy: WAREHOUSE Slopes: N Sewer: TUKWILA TENANT HOVAIR 1210 ANDOVER PK E, TUKWILA, WA 98188 OWNER BOEING WILLIAM E JR 1325 4TH AVE SUITE 1940, SEATTLE WA 98101 CONTACT ROSS LISTON Phone: 206 838 -9599 P.O. BOX 62, MILTON, WA 98354 CONTRACTOR WEZLY D CO. INC. Phone: 206 854 -6420 P.O. BOX 5697, KENT, WA 98064 ************•******************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: ENLARGE EXISTING PAINT BOOTH. Units: 001 Buildings: 001 Fire Protection: SPRINKLERED UBC Edition: 1991 * * * Front: Left: SETBACKS .0 Back: .0 Right: Valuation: Total Permit Fee: . 0 . 0 8,500.00 182.70 * * * *4 * * * ** d 3,********************** �* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** A/ ml Center Auth 5)9Cq ignature Date t I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this b ilding permit. Signature:_ ZL Date: 7-S''` .1 C� Print Name: _,ES„L ,g__p._ 6 1__ Title:. 115112E$JD. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. All PERMITS ISSUED FOR NEW CONSTRUCTION, REMODELING, OR DEMOLITION PROJECTS REQUIRE CONSTRUCTION, DEMOLITION AND LANDCLEARING WASTE MATERIAL FROM THESE PROJECTS TO BE RECYCLED AT A KING COUNTY LICENSED OR APPROVED FACILITY, OR TAKEN TO REGIONAL DISPOSAL FACILITIES. CITY OF TUKWII 4- Department of Comrnunity Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER PROJECT NAME SITE ADDRESS ovaAr aio Pk SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMENT: ,i BUILDING - initial review FIRE 5- 1c0-��U APPROV et* _JROUTED) _.j. FIRE PROTECTION: lS� FIRE DEPT. LETTER DATED: (o INIT: ,S1� 17p iEQ:UIREMENT CONSULTANT: Date Sent COMMENTS .. ..... ............................... Date Approved O PLANNING O PUBLIC WORKS k INIT: INIT: �v ZONING: REFERENCE FILE NOS.: MINIMUM SETBACKS: N- UTILITY PERMITS REQUIRED? BAR/LAND USE CONDITIONS? PUBLIC WORKS LETTER DATED: s- E- Yes No O OTHER INIT: BUILDING - final review A) BUILDING OFFICIAL INIT. TYPE OF CONSTRUCTION: INIT: CERT. OF OCCUPANCY? OYes ,No UBC EDITION (year): ICI9 REVIEW COMPLETED AMOUNT OWING: -' 1 .. • CONTACTED � � 0' c2 DATE NOTIFIED f L '� L.J BY: ...._af3 (init.). 2nd NOTIFICATION BY: . (init.) 3RD NOTIFICATION BY:. (init.) 01/08/93 CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING; PERMIT APPLICATION PLAN CHECK NUMBER • A TI QN >MUST, BE QOMPLETEL Y_ DESCRIPTION BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE ,AMOUNT-.. # t� *oo :DATE::;.. OTHER: TOTAL +0; SITE ADDRESS SUITE # /A. /O A/vDo✓ER f gr?KC 4- VALUE OF CONSTRUCTION - $ rdi 8.-do ASSESSOR ACCOUNT # 35230 `x`: f0 ?s — '7 (commercial) lJ Demolition (building) 0 Other PROJECT NAME/TENANT /-b, vA� R TYPE OF 0 New Building U Addition (Tenant Improvement WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) DESCRIBE WORK TO BE DONE: 7"t/ gNi. A RG E f9 FX J-,5 7 /t(!v F iNT'- 3 or, BUILDING USE (office, warehouse, etc.) F 4flPx ATZO/✓ NATURE OF BUSINESS: n/erA1- F46,2xchia-z' -s WILL THERE BE A CHANGE IN USE? ® No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: 301 siza in Tenant Space: acr Faz izt Area of Construction: > zoc, ,1 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 0 No 0 Yes IF YES, EXPLAIN: Bids ,T,vG, ?AxNr- 300 ry FIRE PROTECTION FEATURES: 21 Sprinklers 0 Automatic Fire Alarm System PROPERTY OWNER t.3 �kLcA -M E. 2 �Z N& PHONE t,Zl` - • w Rs//. ADDRESS /325' fo u Z--r t% /90e .f .S 2.72 if yo SBA. CONTRACTOR Co(0ST- zoc.rrc,,J ADDRESS P0, ads 6i Pi) rk,. -r-6 U.triStt. WA. ST. CONTRACTOR'S LICENSE # .�.,,FG ic tat R K ARCHITECT ZIP 7�'/o t PHONE 832- 9599 ZIP %•5�i EXP. DATE 4_ (c9 PHONE ADDRESS ZIP 1.: HEREBY::.CERTIFY :;THAT ;I H • BE TRUE AND CORRECT, `AN BUILDING OWNER r� , OR PRINT' NAM t12 /� /� AUTHORIZED k- a.,llac toy,. F. gotmNS V,E READ SAND EXAMINED THIS. APPLICATION AND KN 1 AM: AUTHORIZED TOi'APPLY,`;FOR THIS PERMIT_ DATE AGENT SIGNATUR $--/i/ /4y PHONE bay-tick/Ty ADDRESS r v o / 4 4 sum= f q yo CITY/ZIP Scurf -. vet)/ CONTACT PERSON 14t4 C"44---"i5.41),`) ?0,57-5 /I.STpN (rLF PHONE 401 ty'y y 838 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431-3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES SUBMITTAL CHECKLIST • COMMERCIAL NEW COMMERCIAL BUILDINGS/ADDITIONS F-1 Completed building permit application (one for each stnicture nAssessor Account Number::::: • Two sots (2) of the following: . : • . • :Specifications ; • Structural calculations stamped by a Washington State Iiconsed onginoor • . Soils report stampod by a Washington State licensed engineer ; 1 Topographical survey : ; 11 Energy calculations •starnped by :a .WastiingtonState...1iCensed::::,:„,.;; engineer or architect • • •: • • • - • ::: • • • Legal description • Working drawings,,stemped.bY a Washington State licensed • architect, which: include • • • Site pia ri . . ::. • ...I.': • • . . ;.- • Architectural drawings Structural drawings :•,:•, Mecnanicai crewing EleVations.i • .1 Civil drawings Landscapo plan . ...„. . . . ..................... Completed uulity permlt application (one for entire project) --...:••••••.1, • • Six (6) sets of.civii.drawings . • ••••-•••••••••••::: NOTE: :See utility permit aPplicatiOn:and Checitlist for,:specifio submittal requirements. • RACK STORAGE ..„- ........ .:••• . .1 .ASSeisSor.:ACcOUni.,NUmber:. . . • . ...•••• • • •• : Two (2) setS'of :Oen i,:•Whi ch: yid(); . :Building floor ;plan showing . . • ..:• ::• Entire space where racks Exit doors. •:- • -.• Dimensions of :all . . - • • • • •, . • . - „ . . Tenant Space floor plan showing:reek:storage • exlts NOTE:. Include dimensions of racks (lteight,,:width and length ) ,- aisles and exit ways on plan. : ..• • .• 1 I Structural calculations stamped by a: Washington:State1icrsedi.::::.: ••: engineer (rack storage.:8'..and RESIDENTIAL COMCM. Completed twAoss;::::coc.f ' • • ndscapo • • ; nofp• 13 •t:spPP.. . :La • . . . •••' . • n plan (if • erall irnens Ons:.of. °!..• • Use of adjacent .Corrintion Floorp • Tenan rs. d°° xisting iant ;,•• • • NEW. SINGLE-FAMILY. DWELLINGS/ADDIT1ONS.::::::„.„- • • . • • ::-:::: • • . ::• . . . Completed building permit application (one for each structure) Log al description ......................................................... Assessor Two sets (2) of working . • .. • •.:. . ••••„..!. plar;:ii.i6W:C/Osesr Fioor plan ....... Roof plan ....... .......................................... ..... . . . ....... ......... BUilding:eievetions: (611:Viewa ) • :.• ..:,............ Building cross soction •• Stn.ictural framing plans .............. WaShingion:ttate.Eriergi.:0Ode data SiZ:'(S)-Seti: of . Site:PlanS ; showing . utilihes NOTE Bullding . . . .. . site plartand Utility sheplariraaktirifICoin submittal requfrements utillty.OrMit. application and checklist for spfFific... Additional topographical site ..,...... . .... ...... . . " ...................................................... is to be demolished ... . . . . • ial• ::•••••": " NOTE 1! any utiI,ty . . ................................................................................................... Structural caloulations stamped by a • .... ... . .. *. REROOF [1 Completed building permjt appticadon (one for each structure) Narraiive ••••••aii1::4ng and sign • • 0 . . . E. 041.... SAT • Completed tiUliding permit application RESIDENTIAL: REMODELS..:; .: struturo) .. . .. ; . - •:•:•••",••• • Assessor Account Number Sito plan Foundation pian FI'r plan Roof plan . „... Bullding Bullding cross section NOTE if any ut;Isty Work Is to be done provide uti/i and • • REROOFS j at1011,. (Qne ,•••,•• issessor Account Number • .. . . .... • • •'• 0!! of the permlt ......... *k ***•k ** *k * * * * * *•k* rot** * A**1 s* k• k****** * *** *•k * *h *•k *•k** ** ** *kh *k*kk* CITY OF TUKWILA, WA TRANSMIT **** k***************k• k******** kk* ** *k******* * *k ***k***** *A * * *k ** TRANSMIT Number: 94001023 Amount: 30.00 05/12/94 13:32 Permit No: 894• -0184 Type: B-BUILD BUILDING Pl'{Ithla94 Parcel No: 352304-9075 Site Address:. 1210 ANDOVER PK E Payment Method: CHECK Notation: reirupection )nit: SOS * * * *** * * ***k k * * * * * ***•k * * ** * * ** k *k4 * ** * * * * ** *** *** h * *A•* * * ** * *A * ** Account Code L)escr i pt iq 000/3221100 BUILDING NONRE5 Total (This Payment): Total' Fees: Total All Payments: Balance: 212.70 212.70 .00 •+ Paid 30 «00 3.0.00 GENERA TOTAL CHECK CHANGE 4652A000 30.00 30.00 30.00 0.00 15:59 ************ ****************** k** ******* *A*** ******** ****** ***** CITY OF TUKWILA, WA Reprinted: 06/3.5/94 16:19 TRANSMIT. ******************* kkk******k****** *******•k*** *** ***k*** *.******* 112.50. 06/15/94 16:18 TRANSMIT Number: 94000701 Amount: Permit No: 894 -0184 Type: B- BUILD BUILDING PERMIT Parcel Na: 352304 -9075 Site Address: i210 ANDOVER PK C Payment Method t• CHECK Natation: O L F CONSTRUCT Iri i t: SLIT k •kk•k*k**kk***********A••k*•k*/ ********A**** *****k****.k***k k* kkkkkk k 06/16/94 Account Lade 000/322.100 000/386.904 Description. BUILDXNG NONRES STATE .BUILDING SURCHARGE Total (This Payment): Total Fees: Total A•11 Payments: Bal ante 182.70 182.70 .00 Paid 108.00 4.50 112.50 GENERA: GENERA. • TOTAL • CHECK: CHANGE • 2861A000. 108.00 4.50 112.50 112.50 190ig • : t.** k** k***************** h**** k** k* k*4: l • *k * *k * *•k **k *k *'*** * * *:1**k *•k CITY OF TUKWILA, WA TRANSiMiIT. * ** * * * *k* *** * ** * *•k** *.4.** **, ****** k •k*• *k**** * **•k**** ****kk * * * * ** TRANSMIT Number: 94000554 Amounts,: 70.20 05/16/94 10 :42 Permit No 894--0184 • Type: 0 -BUILD IIUILI)TNG PL`RMW /16/c)4, Parcel Na: 35230.4 -707 Site Address: 1210 ANDOVER PK E Payment Method: CHECK Natati.arra 0LF CONSTRUCTION Tait: SL.l * k** *** *. * *** *k *A4* ** ***** *•kkot•**** kit •kkrF** * ** *k** * ******* *•k *** Account Code Description. Paid .. 000/046.830 PLAN CHECK -• NONRES 70.20:. Total (This Payment): 70.20 Total Fees: Total All Payments: Balance: r 182:70 70.20 112.50 ge GENERA 70.20 TOTAL 70.20 CHECK 70.20 CHANGE 0.00 1967A000 09 :43 CITY OF TUKWILA Address: 1210 ANDOVER. Pic. E Suite: Tenant: MOVAIR . Status: ISSUED Type: B-BUILD . . Applied: 05/16/1994 Parcel #: 352304-9075 Issued: 06/15/1994 ********.k**************4(***************************************A********** Permit Conditions: ' , . ;• . 1. No changes' will be made-to, 6,701irCliiireS s approved by the • , T u k W i 1 a 0 u i 1 d 1 n g D 1v4451*., 2. 'Electrical • permi t4,411---be 6,Ye o, bt aru i n e drdi• th rougdoht1 W 4llas• ht,rinigato1 n State Division 41; r f.s t s n 1 .c wo rk w i 1 1 bt, Ji Vr t 0 4:C*j;) a 0,9,0)c .„ ( 24 g4- a 30 ) IA .4.0 3. All mechan /Woticlit ail) be under septaraka ke t th10).!gh the City • •ukt‘it:11;s: The ,Anstfteligeibilegf nei,v,,e aust*.i, 0 Al) 0 / unit and auti` stack .§hal I be veccompl isttexl, un 1, 'b't pa0 s ;permi t . 'kw,. 4,4.2 •:\'‘,0,1 (1 0 6 4. All pe ts, in§'Peg,t11 on rteib pds, and approved 151, a n s sp.a 1 1 ma int pe ay a i 1 a brl e a tyM4 (913 s 1 te'rp r i or to t h ev, start of' any construct1on ' These ''' do c uTaRt,s" a r e to be ma intlira-400 avai 61 .;:d.141(riftri 1 1"f i n a 1 '13) spe c tfi .0 ri---approval i s grantad. 5 , s . Al 1 io"nstru$t ion to be:done„.4t, conformance with appFtoVe.dp pla 44,• an ti,244'44ucl rem eptof,- t hial 14n i f ot.m,y8Child i ng Code (1991 ,' \3(44 fit.53 Ed iiplon) as .amended bk.'-sthei., Was h0 p.g.i'dlitri Siat.a-.1Bu i 1 d i ng '*„posiwT-1, IN Un„151,rm (4 dharfidas1 Code (1991 - E ih tiiibin ), ,,,ii.:1 and Washington State v''' En a gy Code (1991 •, Second -/E01,M on ) .•,, \ IfL...•-----,..,:r, !, ,,,:o, 1. ,v. • 6 . Va '1; Al ty Orf• P a rmi•p''.- .T.t.i.erl'i s'Xace,'?4:if 'LA ,p-ei r zinft o a p p 4 v alm:DA 1 ' p 1 i#1,. 61;•.,01 f to a t.`iorfi aryti,../b oliikt.t,a il a,n s,„ shall n o t be oon --. str.k.teki to be at p e riii tt:::,:tor,ror a RN, approval ) k," o f„, any v i 0 atiflon o f drA. • of tt 6e 'Aro v i s i on s of thisVd6de4dr/oe.any other ,4 0 r d 'Ng V C'e :AO' the Jur 1 sdi ct i oh . No;'—p-armft pres6ping I to,49fre , - • 1 a ' ' 1 , \ ' r.,..''-'. "".. . auth ri t .of'4' violate or cancel ther' pto■clisi ons= 14 this ,,p,o& ,,., N t., shall' ike yv1 i J.,--- \:, Or' • ' 0 4,,;.4.- Permit. No: B94-0184 '1.44 6 • •• , 5 SPEOTION O. C, INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 PERMIT NO. (206) 431 -3670 Project: lj,G VA, ype o ns. , «,►— Address: 1 ez , f 0 ,/L o 6v bv Date Call, .: Special Instructions: pit, , �. , `/ 1� Date Wanted: s/ 17 , 0� (�' 1S 1 m. Requester: j tx., li 0 Phone No.: q. 5 & 4,-2_ 0 .pktproved per applicable codes. ❑ Corrections required prior to approval. ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. t SPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT (206) 431 -3670 'ro e iit, ype o nspection: •are? I0 MP 0-0E4 qV ' 5 l7''_a►ir- Special Instructions: late Want s Requester: b `'�e Q ill'' Phone No.: g4 (o `i" .2-D ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: " rifr.e _ /71,24e,„?f-ieS1.- ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. NSPE • N 0. C INtSPECTION RECORD Retain a copy with permit PERIM' 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • roject: � , I ype o nspect • n: �� Ld) ' Address:/' 2//1: L 54; /l )- Date Called: y 10/ ?// % Special Instructions: �/ // Date Wanted: / am. plJ Requester: gin, ef2_. Phone t/i 4 CULL D + 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: E7e4--- %4.--/ 'f-d, % /.1.-70?'/ 54; /l )- 1,.. "Y,‘"( • .... ,•' •i '....i .. AN.. f/ ,r ; nspector: Date: $30.00 REINSPECT 'N FEE REQUIRED. Prior to reinspection, fee must be paid at 00 Southcenter Blvd., Suite 100: CaII to schedule reinspection. 1. _.... ,.3 - .� INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • (206) 431 -3670 Project: , (ypeoilnspection: / , ,, de. Address:/ a,,,d Date Ca e.: ; At Special Instructions: ��� � Date Wanted: i8' r am. p6 Requester: / ll�� Phone No.: ; 12� pproved per applicable codes. COMMENTS: ' Corrections required prior to approval. t_ C.sLti ! i cAJ ` ' ` r�- y�J.r•� 7� cs-ttle_suLd■ —AAA, Inspector: (0 ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be pald at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. 'nc..� "' r7.- �:+1f .: �: . '7 • • • *** * ''`.. INSPECTION RECORD Retain a copy with permit I SPECTION O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Ivd., #100, Tukwila, WA 98188 (206) 431-3670 Project: )(di-yew& ype o spection: ' / ar 0 oele-- Address/a110 or ,,,a,„ Date Called: 2 dr Special Instructions: /le( 47 Date Wanted: a.m0 Requester:, .6d) t Phone No,:, c54.2 6 LI 26 ID Approved per appllcable codes. COMMENTS: ' Corrections required prior to approval. 2_, `6,t4 .00 REINSPECTION FEE REQUIRED. Prior to reinspectiqfeemust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectierk " ecept o.: Date: City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name /*IO U A / • John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. er/r. Address );*L /& /3. /' Retain current inspection schedule Needs shift inspection 509/49y 1 17 Approved without correction notice Approved with correction notice issued Suite # Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Au horized ignature FINALAPP.FRM Tit/e6/9(/ T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 Phone: (206) 5754404 • Fax (206) 5754439 LEGAL DESCRIPTION - BUILDING LAND That portion of Government Lot 1, Section 35, Township 23 North, Range 4 East, W.M., in King County, Washington, described as follows: Beginning at the Northeast corner of said Section 35; thence North 87044'08" West along the North line of said Section 35 a distance of 449.48 feet; thence South 01051'39" West a distance of 237.95 feet; thence South 88008'21" East a distance of 30.00 feet to the true point of beginning; thence continuing South 88008'21" East a distance of 253.00 feet; thence South 01051'39" West a distance of 334.32 feet; thence North 88008'21" West a distance of 253.00 feet; thence North 01051'39" East a distance of 334.32 feet to the true point of beginning. Situate in the City of Tukwila, County of King, State of Washington Per rider attached hereto and by this reference made a part hereof: SUBJECT TO: Restrictions imposed by instrument recorded under Auditor's File No. 5256443, amended by instruments recorded under Auditor's File Nos. 5332848, 5500900 and 6138154, and Amendment No. 4 recorded under Auditor's File Nos. 6138155 thru 6138173, and Amendment No. 5 recorded under Auditor's File No. 6180358. Reserving unto Grantor herien, its heirs and assigns, an Easement for railroad right -of- way and utility purposes over the Easterly 27 feet of property herein described, said Easement to be a convenant running with the land. RECEIVED CITY OF TUKWILA NAY 161994 PERMIT CENTER 133058 EXHIIK3F "A" 3 Z .3 43, • • • • • 6. P 4 631 81c7fi TREE , ''P, At.-4N& : .!I * I 1 • ••714.7., •\%P...,T":t, i1i• 1 • • • ". .-Z.7•,!-■.(."7 :.,,-1.. !: .4"/ 4..,,'' ", ;.;'71...*,.".r..'e •1.. :r-.17. ,..' "■ 4 ,4141.:,.:. e,v.. • ;S.:.r..X ..7',;e77,: n :.;':•.!.•:: "..", : .'" %........:: Vo •. V 1 P. . ' •1 • ' ''• . ti ' ../.. • ''. , .9 C A k.....& .. ,...... ...,,-...........,.......... ., . : ..:,:........, tit f "I r ••• ; . . . .1. f..7 . ••• I-751-4" • I -Tg.or.44 • 1,••••••••••••••• 114 • p—r—wairs 1 ••• -4c OF. LI ILA. ‘4PPROVE'D. .JUN 1994 A c-, BUILDING DIVISION CITYWMIA MAY 1 6 1994 PERMIT OBITOR i 1.— --- 1.3ci3OSO •••••••••• • < t.r:11r, 11 • • .'" •;"•,. . „ 1...! r• te City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #B94 -0184 (510) Re: Hovair - 1210 Andover Park East Dear Sir: John W. Rants, Mayor June 6, 1994 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Provide a minimum 4A 40BC extinguisher within 30' of your spray booth. (UFC standard 10 -1) Maintain fire extinguisher coverage throughout. 2. Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 3304(b)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 12.106(c)) City {uf Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor 3. An approved automatic fire sprinkler extinguishing system is required for this project. (City Ordinance #1646) All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1646) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd JUN-24-94 F R I June 24, 1994 T :27 HOVF4 I R -SYST S- I NC . To Whom It May Concern: P . 2 h.v'UIr HOVAIR SYSTEMS INCORPORATED This letter Is to inform that we are changing contractors from Ken R. Humke Co. Inc. to Wezly- D -Co., Inc. for the purchase and installation of a paint booth. The original permit application was approved and Issued to Ken R. Humke Co. If you have any questions please feel free to give me a call. Regards, idicaZ Betty J. Cloutier Sec./Treas. CITY OP Tu ° KWILA JUL 0 5 1994 PERMIT CENTER 1210 ANDOVER PARK EAST / SEATTLE, WASHINGTON 98188 /.12061575.3306 CAW, 17N.1 ;7441/10. AM.717.44IA 123/ :JLE. - 7/ —1-62.77 L c3 R—?5-92' /0tr)ty d_24 n 4-e t Of __Y-daq__•-"Atg-' . '. 64 ,L,u,ked Lf I-L/ _& • •" REGISTERED AS PROVIDED BY LAW AS A: REGISTRATION NUMBER =1.,a.. L DC .1.4311.8. .ZLY" 0 Cr./ T ?r P 0 :3O X 56 97 I<rhr EXPIR ON DATE 1,: /:'.A19ri 98664 SIGNATURE ISSUED BY DEPART • ENT OF LABOR AND INDUS IES W CITY OF TUKWILA JUL 0 9 1994 • PERMIT CENTER to Fit [a� AM ids i .....,. r,,., .....,...11.,,.,,,.111.,:.tl.,,,"MO FILTER ELEV. NOTE: The DeV I LB I SS Company 1 993 REAR ELEV. IMPORTANT NOTE -- This pr 1 nt i s the con+ I dont i a i property of DoVIibIss Spray Booth Produots. an I11!nots Too Works Conpclny. It is not to be used or reproduced In any manner► nor submitted to other part 1 os for exam! nat i on without the pr t or capprova I of DeViIblss Spruy Booth Produots. r -- (36) 20" X 25" CELLS W/ ROLL MEDIA FILTERS. SUPPORT O EXHAUST FAN & STACK TO BE 8' Ercs, OTHERS THAN DeVILBISS. SUPPORTS MUST BE INDEPENDENT,,'" OF BOOTH fre 1 e. t)e' ham , 13`-0" MINIMUM C) t 0 N_ LL. C) (NI CD 0 0 0 LL 0 N 0 LL 0 (-I 1 CU 7 23' -4" 0 ;NI 0 _J 0 U 0 (NI C9 Li- -J 0 N 0 C) PLAN VI E W 1 SIDE ELEV. ALL O!MENSIONS ARE APPROXIMATE AND SUBJECT •1O CHANGE. CUSTOMER TO CHECK EQUIPMENT SIZE. LOCATION IN BUILDING. AND ALL INTERFERENCES AND CLEARANCES TO BUILDING AND CONTENTS. _2 jll ii{+. ! Ii{ Iji{ Ill1jfi {I`I {I,I {(1t {i1l {ilijl1!1I fll1 l {l11 {� I' 11111 1111 11111 1111 1111 III{III II 1111111111 0 ,8',...94.-, ,8',...94.-, 1 2 r3 4 5 6 7 8 NOTE: I£ the microfilmed document is Is clear than this notice, 11 is due to the quality of the original document. /77 0 DeVILB1SS 1. NOP ,_,_. M.Y./M.94Y lYnE; S/ ii YiMiTWQY i rt.N.Y",AJrY.n•:.,ti ....rr. 1ly ,. A 4- 215 -94 1" II ti H 5-04 -94 DRAWING DESCRIPTION CORRECIED CM. 1i 1 ii I,I iI I H_______ Ci _..a...r...t I 1_011 20:_.011 SIDE ELEV. ALL O!MENSIONS ARE APPROXIMATE AND SUBJECT •1O CHANGE. CUSTOMER TO CHECK EQUIPMENT SIZE. LOCATION IN BUILDING. AND ALL INTERFERENCES AND CLEARANCES TO BUILDING AND CONTENTS. _2 jll ii{+. ! Ii{ Iji{ Ill1jfi {I`I {I,I {(1t {i1l {ilijl1!1I fll1 l {l11 {� I' 11111 1111 11111 1111 1111 III{III II 1111111111 0 ,8',...94.-, ,8',...94.-, 1 2 r3 4 5 6 7 8 NOTE: I£ the microfilmed document is Is clear than this notice, 11 is due to the quality of the original document. /77 0 DeVILB1SS 1. NOP SIT M.Y./M.94Y lYnE; S/ ii YiMiTWQY i rt.N.Y",AJrY.n•:.,ti ....rr. 1ly ,. A 4- 215 -94 FILTER DOOR SIZE REVISED _ C.O. =._ 5-04 -94 DRAWING DESCRIPTION CORRECIED CM. SPECIFICATIONS EXHAUST: (1) 34' DIA; FAN ASSEMBLY WITH 5 H.P. TEFC MOTOR (230/460- 60-31 RATED 21,205 CFM AT 025' SP. MY Pfu(; PROVED JUN 1534 BUILT) NO DMSiOI SEPARATE PERMIT RE UIRED FOR: 'MECHANICAL �t.EDTRICAL [__J PLUMBING RATED 20,082 CFM AT 0.50' SP. t. a PIPING CITY OF TUKWILA BUILDING DIVISION UGIITING: (2) LCI}120, FOUR TUBE, CLASS 1 DIV 11, FLUORESCE FIXTURES (120-60-1) (8) LFG -120, FOUR TUBE, GENERAL PURPOSE, FLUORESCENT FIXTURES (12.0 -60-1) AIL FIXTURES LESS TUBES. REVISIONS NO CHANGES SHALL BE MADE TO THE SCOPE OF V4'ORK WITHOUT PRIOR APPROVAL OF TUKWILA BIJILDING DIVISION. NOTE: REVISIONS WILL REQUIRE A NEW PLAN SUBMITTAL AND MAY INCLUDE ADDITIONAL PLAN REVIEW FEES. PILE COPY 1 urlderst (rtci that tha Plan Check subject to errora and otniesIons IInd cpprc •...f of plans does not 010 1041•141 ffi won of ony adopted coda or oftithatffo of c on n ctz copy of approved OM BY DAG LI= N*...fila-:...atfUl_. FRONT ELEV. NAME Or PROJECT HOVAIR SPRAY BOOTH PRODUCTS ¢--w • 41141111 {1111111{I1111111i II 1111 11111 11111 I 11I 10 11 w,nE 1+4 GERMANY 12- 0 D'etAtiti I tY BYiM CHECKED CKED BY DAVE 4-.25-94 SCALE i ECEIVED CITY os= TUKWILA MAY 16199t 1 MVT CENTER DESCRIPTION D MIRO 18'w X 10'h X 20'0 PROCLEAN BOOTH BRAVING NO 6796-94 _ . . .. . _ .r. rr. •f ,•f Jr:.... f .h {L 3-' i. � t f rf .-, a .f (Y u e .. :-xc. .¢ .x ., d. . -.fir lcR i. rt e r ... �L+. r�.: .fr .1 _.. Q; 6E 8C L7. 9E 9E 4i3 £E. 2.'!E tE OZ St fit Lt 91 st pit EL Et tt (�i1 6 t3 1111; 111111111 11111111! 111111111111111111111l11111111Hh11 11111111 "41111!11111!.1111 1!111,1.0141 Rill!! f.i!!i111►1111l�i61 '!11111 ►t 1111111110,11':1111111 i, I .i11111111111111111101111111i11 111117111111111111111111111, f NW Q '1111111111111!1 1111: 111111111111111111111111111111 11 ;11111111 ;111 A 4 -w44 IL1p1 pet 1 11e444 DRAS1N gQ TION SPECIFICATIONS EXHAUST: (1 139 DIA FIN ASSEMBLY WITH 5 HP. TEFC MOTOR (230/46031. RATED 21,205 CFW AT 025' SP. RATED 20,092 CFM AT ON SP. COY 1 MOTO JUN LIGHTING: (21 LCD.12O, FOUR TUBE, CLASS I DIY 11, FLUORESCENT FIXTURES (120£011 (81 LFG -120, FOUR TUBE, GENERAL PURPOSE, FLUORESCENT FIXTURES (12011 FILTER ELEV. ID (36) 20" X 25" CELLS W/ ROLL MEDIA FILTERS. NOTE: SUPPORT • EXHAUST FAN & TO BE B OTHERS THAN DeV SUPPORTS ST BE INDEPEND OF BOOTH AS NE S INStus4TION ut40EI. Wee l EAT' E ME:C.4044CM, QERM%t REAR ELEV. 0 The OWILSISS< eery 191I IMPORTANT NOTE - This pr 1 nt le the conf t dent t a t property of OWIIOIN Spray Booth Products. an Illinois Tool Morke Company. It le not to be used or reproduced In any manner. nor etb Itted to other part 1 N for exalt net 1 en wt thout the pr 1 or approval or OeV110tn Spray Booth Produote. c 0 M .1 11 11 1 11 1 I I I I 1 \ /\ / `\ / / / \ EN - a' ■■I - - ---- 0 N I 0 -..1 0 N D � _J I l I I l I 0 N 8 I ♦ 1 I1 1 1 I1 11 11 1 r1 11 11 1 1I 11 11 11 11 11 II II 11 II 11 II II 1 1 I I I 3' -0" N J i i L__ J 1 1 1 N I __ J I I I I 1 •I I I 1 I 1 ':� :: i I I I I 1 L__L__1__1__J__J__ -:: I I I 1 I I 1 I 1 1 I 1 I:_ • :� I 1 1 1 1 1 1 I I L L I. .1 -I .J ..��e L 1 I I 1 1 1 1 1 I 1 I 1 1 1 1 1 I I 1 I 1 I 1 1 1 I I ' I 1 FILTER ELEV. ID (36) 20" X 25" CELLS W/ ROLL MEDIA FILTERS. NOTE: SUPPORT • EXHAUST FAN & TO BE B OTHERS THAN DeV SUPPORTS ST BE INDEPEND OF BOOTH AS NE S INStus4TION ut40EI. Wee l EAT' E ME:C.4044CM, QERM%t REAR ELEV. 0 The OWILSISS< eery 191I IMPORTANT NOTE - This pr 1 nt le the conf t dent t a t property of OWIIOIN Spray Booth Products. an Illinois Tool Morke Company. It le not to be used or reproduced In any manner. nor etb Itted to other part 1 N for exalt net 1 en wt thout the pr 1 or approval or OeV110tn Spray Booth Produote. c 0 M .1 11 11 1 11 1 I I I I 1 \ /\ / `\ / / / \ EN - a' ■■I - - ---- 0 N I 0 -..1 0 N D � _J 0 N w J 0 N 6 J 0 N 8 ♦ 1 I1 1 1 I1 11 11 1 r1 11 11 1 1I 11 11 11 11 11 II II 11 II 11 II II I I II II II I II II 3' -0" N J N J N J T N N __ J 1' -8" // \,� 23' -4" PLAN VIEW 0 1 rm.n ILBISS. A TRI -I \ /\ / `\ / / / \ EN - a' ■■I f O ! O 1 r1 11 11 1 1I 11 11 11 11 11 II II 11 II 11 II II 3' -0" 1 20' -0" 1394-DISLI SIDE ELEV. ALL DIMENSIONS Ant APPROXIMATE AN0 SUBJECT TO CHANGE. CUSTOMER TO CHECK EOUIPMENT S111. LOCATION IN SUILDINS. AND ALL INTERFERENCES ANC CLEARANCES TO BUILDING AND CONTENTS. 10' -0" INSIDE um Falb ,U � 0 PLUMBING 0 OAS PIPING CITY OF TUKWI.A WILDING DIVISION ALL FIXTURES LESS TUBES. REVISIONS P40 CHANGES SHALL BE MADE TO THE SCOPE OF WORK wmiouT PRIOR APPROVAL OF TUKWILA BUILDING DMSlON. NOT! I IERIMO N DLL SERE A NEW MAN suuwi& AND MAY INCLUDE ADDITIONAL MAN REVIEW FEEL. PIKE 00F11 1 Idw.Klnd VW Ihs PIr1 OMKk Approve-, 73 WAKE IK wren red alle.W_ old spprc•.J Ins dam met allhalal SO tail= a any add _ w Slr d INWEISSI O WBrad Ode S swift .lqq- 0 I4 L1 r / \ I\/ A TRI -I \ /\ / `\ / / / \ \/ EAF F LTER 1 V if DeVILBISS SPRAY BOOTH PRODUCTS 2' -0" /\ OOR \ J/ \ \ 7\ >/ >/ \\ /\ /\ / \ I 12' -0" DOOR 16' -0" INSIDE FRONT ELEV. 2' -O" IMM t ROM HOVAIR ■ tls U ea 1N'w' X h X 110'4 PNOCLEM INABI h ORM IT MIS as 4•11-114 Ivr • 1'-r 6796 -94