Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit B94-0305 - MCNETT RESIDENCE - NEW SINGLE FAMILY RESIDENCE
(206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT �C //� Permit No: B94 -0305 Type: B -BUILD Category: NSFR Address: 4652 S 160 ST Location: Parcel #: 222304 -9105 Zoning: Type Const: VN Gas /Elec: GAS Wetlands: Water: UNKNOWN Contractor License No.: DLMCNC *062Q6 Status: ISSUED Issued: 12/14/1994 Expires: 06/12/1995 Suite: Type of Occupancy: DWELLING Slopes: Sewer: TENANT MCNETT DAVID 4652 S 160 ST, TUKWILA, WA 98168 OWNER PARSONS LORRAIN Phone: 242 -3279 4646 S 160 ST, TUKWILA, WA 98188 CONTACT DAVID MCNETT Phone: 206 248 -5614 4652 5 160 ST, TUKWILA, WA 98188 CONTRACTOR D L MCNETT CONSTRUCTION Phone: 206 248 -5614 16019 47TH AVENUE SOUTH, SEATTLE, WA 98188 ******************************************** * * * ** * * * * * * * * * * * * * * * * ** * * * * * * ** Permit Description: CONSTRUCT NEW SINGLE FAMILY RESIDENCE SETBACKS Units: 001 Front: .0 Back: .0 Buildings: 001 Left: .0 Right: .0 Fire Protection: SPRINKLERED UBC Edition: 1991 Valuation: 145,808.35 Total Permit Fee: 1,345.33 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this bui l ng ermit. Signature:__ Print Name:__ Pc 1 � � 1 X111 Date: ,/d4,7 Title: __ -11.A1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. All PERMITS ISSUED FOR NEW CONSTRUCTION, REMODELING, OR DEMOLITION PROJECTS REQUIRE CONSTRUCTION, DEMOLITION AND LANDCLEARING WASTE MATERIAL FROM THESE PROJECTS TO BE RECYCLED AT A KING COUNTY LICENSED OR APPROVED FACILITY, OR TAKEN TO REGIONAL DISPOSAL FACILITIES. CITY OF TUKWILt Department of Community Development — Permit Center 't 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER 1394 -0305 PROJECT NAME _ it i 1 SITE ADDRESS 4 (o S AV io ) (L Srl— SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMEN;Y TE:I KBUILDING - initial review FIRE 14LANNING 8-2.a-q1 f 'DATE:. 'APPROVED; C.f R. ROUTED INIT: V44 'b 6-•)! ,(i INIT: 4.. )40I`i REQUIREMENT MMENTS`: CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: Sprinklers (1 Detectors • N/A FIRE DEPT. LETTER DATED: C, — $ tr INSPECTO-. 6t-, ' ZONING: REFERENCE FILE NOS.: )BAR/LAND USE CONDITIONS? (]Yes No MINIMUM SETBACKS: N- PUBLIC WORKS 0 OTHER UTILITY PERMITS REQUIRED? PUBLIC WORKS LETTER DATED: s- E- Yes No INIT: INIT: BUILDING - final review BUILDING OFFICIAL INIT: C INIT: zZ TYPE OF CONSTRUCTION: 1lN CERT. OF OCCUPANCY? 0Yes 'fNo UBC EDITION (year): Frist REVIEW COMPLETED AO T OWING: . 0 0 ---70 KC am n^ I CONTACTED ' C '-rAdj-- DATE NOTIFIED 0 BY: s) (init.) 2nd NOTIFICATION �-F�" rnQ(6P.. R�� i I-1 "61y BY: ^^6� init. ICJ BY: (AL________- 3RD NOTIFICATION (Won I t ` ) (o a .60 01108/93 CITY OF TUKWILA Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 p9 /_ ON, 5 PLAN CHECK NUMBER 5/—O3os BUILDII4; PERMIT APPLICATION Division DESCRIPTION . BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE AMOUNT RCPT .# `'; : DATE FOCA 5r) 5403 11-4W. SITE ADDRESS SUITE # q%sa Se /6014 ale iirer VALUE OF CONSTRUCTION - $ 114,51.Y'O vSS PROJECT NAME/TENANT ret LjTenant Improvement ❑ Remodel (residential) $ '7X't,�l7Qti< StiGt,E RqitillY 6Sibglik-E- ASSESSOR ACCOUNT # '3 ! $ c2 )/d (commercial) LJ Demolition (building) ❑ Other _ TYPE OF New Building Addi(ion WORK: ❑ Rack Storage ❑ Reroof DESCRIBE WORK TO BE DONE: !(1lj Y EXP. DATE BUILDING USE (office, warehouse, etc.) PHONE 5 -68_ NATURE OF BUSINESS: WILL T IjERaF BE4_CANGE IN USE t_,v - 17-71 91Z1 8e= No ❑ Yes If Yes, new building requirements may need to be met. Please explain: up 3 6 0 6, Tenant Space: Area of Construction: 9‘,, 0_6? SQUARE FOOTAGE - Building: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? K No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: g S•rinklers 0 Automatic Fire Alarm S stem PROPERTY OWNER iAUt �- �` PHONE 02 ern PHONE ,. c�re/Y ZIP ZIP ADDRESS %1019 X17 , Auk J. 5Zietlit 98!88 CONTRACTOR Swe ADDRESS WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT moat kldt)ot A/ PHONE 5 -68_ y ZIP ADDRESS s6/DFitXNrbd l A _ . HEREBY.:CERTIFY. :.THAT:::.1 HAVE•. :READ,.:AND.EXAMINED:TNIS ::APPLICATION AND. KNOW THE SAME T BE. TRUE AND:CORRECT;. AND 1 `AM AUTHORIZED :TO' APPLY :FOR <THIS`:PERMIT.:: BUILDING OWNER � "r"' �� / C • OR AUTHORIZED AGENT CONTACT PERSON PRINT NAME ADDRESS PHONE je./8 ,%Y CITY/Z IP 63/e PHONE ,2q . APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calcuiated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architectiengineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the DeparlmatillOgUtommunity Development Building Division at 431 -3670. ITY CIF tt tKWILA DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES c9014, cow 2 2 1994 ,, '1• COMMERCIAL SUBMITTAL CHECKLIST . .E: . . . . • . . . . :••• NEW COMMERCIAL BUILDINGS/ADDITIONB .. .IH.. 1 1 ... Completed bUilding:permit.applicationlone for: each. structUrey• ..... AssesSer,ACcoti.nt Two sots 1 (2) of th e Following •••••:•: Specifications ....................... :.:............... ..„ • : ongineer • •••••:••••••••••• Cl:•poilp•repoit stampod.by-iWaShingtorfiState.liCensed engirieer:±.J „... nergycalculations"stampedb . .................................................... engineer orarchltoct • • ,... • • • •••••: t-- • Legal description:: .• • Working draWings, stamped by a Washington State licensed ,J.• architect,whicil include:: • • • • • •:, . • . • : :::. • : . •• •-• • • 'Architectural drawings Structurat drawings • Mechanical drawings Elevaons Civil draw,ngs Landscape .. . :„......... plan : • . . . :Completed .utility • perm it application (one for entire ;projeCt) " • Six;(6).tets of ciyi drawings submittal :re . . [ 1 Completed :building perm it • application I. • " .:.• Assessor Account Number • . ............... .......„........ . ........... ••••••• • . . • • Two (2) sets of:planS,,whiCh •• • .:::: • • .; r 1.pu„,„„9 floor plan showing ; • :J. Entire space where racks will beilocated • Exit doors. •, J: :: • Dimensions of all aisles, • ,• • ; . :;•:;.; ; ;:: . . [I Tenant spaCefloOr plan showing rack storage layout; aisles and NOTE: Include dimensions of racksiheight, width andlength), aisles and exit ways on plan.: : ;'; : -; • : : ;:::: : : : . : .•:: . „ . Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over) : • •:::: . . .. • RESIDENTIAL — COMMERCIAL .TANA4T4rApppy4mENT:g •;Completed building Assessor Account Number 'TwO(2)SotS.Of:COnStrUCtiOn;:pliine;•WhisW:jriou . .. • ............. tenant apane Exisng and proposod parking Overall building • • •• . ...................... plan ........ Floor plan oi proposed tenani space • Tenant spaca pkr with usa ot each room IabellE re ss ••:, •".•NeW•Viiiiii6; existing well;:;:p6a**iis:ip::66...cidino6rie94:6.: egress ............................................ . • ••.•••••..:,,• Construction detaits . . Crosi:sectiOna:: showing Wall ::cOnStrLetien:•Sind:Meth ':..attachment tor •StrUCturai„CalCulatiOns itarnped bk:S(WashingtonState,liceriied,:•::: required if,etructtiral work's 19' bp done;:::spbirst:spparp to .. • ..... ANTENNA/SATELUTE DISHES .• • . Completed building permit applicati�ri • Site Plan (showing building and lcGatiQn of antonna/satellite dish) Structural:ealCulationsYstantped:by.,aMashingten:;Statejlithried.,•::::':•:'::::j•: engineer May..be,reqUired NEW SINGLE-FAMILY DWELLINGS/ADDMONS ; •• • • Completed building permit application (one for each structure): . :,..• . Assessor Account Number •••••;.. : ........,••• Two sots (2) of.wOrking:draWinds; . . • •„•.• .•.,: • Site plan plan,thoW.closeathydrant Foundation plan. • Inc.tue1 a. access to • • ; ":' .• Floor. plan : • • . • • Rodt plan • Building: elevations (alt •••:BUIldingcross-section.. • .....,•••••••.-..." • • •••• StructUrai framing plans Washington State Energy Coda data • . Completed • Ultil ity perndt application Six (6) sets at site plans showing utilibes NOTE • . • . . Building:.site•plark.and utilsty she plan:triay!:).6:ooriloiri6d.:•:.;.:,§oti.::::::.,:: utility.perinIra0IiaqiiOn;andchecAlist torSppcilIceubinIttql;■00irernftp0..... Additional topographical and soils".iplorrnation:olay0kreqi#I00:11,.Unigtid,:': • sito CO Ild n • . . • . . . • . • RESIDENTIAL.:REMODELS.,••.:•;;;:.„.. ":" • "" •.. • . •••••:•:-••••::•-•-: .. F---:Completed building permit apPlication:(one:"ferfeacstrUctOre .. . • ": ""•:.:: : ..„ • • „ ....... .„.. ..TWel(2)::sets of.Working.draWings;.Wh.ith..inciude;:.-„;• . 1 1 Foundation plan Floorplan Roof plan Building elovations (alt ews) • Struciural framing plans NOTE 1! any utiIiry work Is to be dono provide • , . - _ • :: • . A Permit No; atu-s Project: P,ddress: Locat ion : Parce 1 #: Wet. lands: Contractor: TENANT OWNER PW94-0106 ISSUED MCNETT SFR 4652 •S 180 ST ON-SITE 22'.1304-9105 LAND AL TERING watercourse. CONTACT IICNETT pp(vEi;' „ ,,' , . '4 44 •A * 44 4 * 4 4 44 4444 ' ** *,1/4:**"'4 4' * * 4 4411. 44 ■It 1, 4h k• 14 '4 4V'4i 4 4 * 4 4 11, itlIk' k Add it iona 1 Des ff.„14 UP TO lOWT.OBIt.'. r4,RDSOF GRACAINGNOP,K44 ,' #''' 11 '' '' 04, .1' ''N ... . 1. l'' G r a d i n gi F t 1 1 4,Y.',Iar d s')''--,7..,,Ctt. .!. 1 0 0.;.,...\ irl':" .., 41 4.,., 4, :4' , . ' P e r m i t 1-,eei: 4,...; .......: . ...., ,... .-.., 4-1-i\ C\11 11 f',1,1 1!....1,, e% ,,,, Account NO: dOL0'22.,T00 re l07; i'2sued: 12:14/1994 Approva i Letter: 09/01/1994 06/12/1995 Slopes: License No.: (206)248-5614 .142-3279 F .,' Ian Check a : f , 4.,,,-14 0 i,00 t,-,N, e A c ct Un t No :...t. 01.10.'/.3.4f."; ...., • • i (..1 1.44 • • 411',Ut, c•4* „ t../i,ttirc r • tr.p,;,t-,, . .,3: .. c c LI n t No : ,0 0 0'7 '3„4 9 . .s..1 ti ti:''' . ., ...,..! c,t \k, Tot 1 ,Fzee.r.fh . .„ .T,. ,.... ,,..,. ,.. ,... !: . '3 7:::. 50 1. ;: - - , • ''Ilaluation: . .... 444444***Ak4101*4*****44*4-44*-444****.*4,0Ck*********44.*444444A4**,444k,*404.4.,4******4 ,. -t. 1 he t. e by -p.i.ej” t • I 't: / t , ; t ht.,..1.i.'1,h' 1".'+ -e-.r e a tf,;, ' , 1 n d ;1 e i e : f s ' m 1 r t ,‘,1*-E h t t i s p e i . m i t n I 1!:. npv.rOr s a me to be t r LtpandJ.,,,c,P.,,r r e t't . Al- 1- ''''P r-P V ttAi on s \t ) ifrol...-- e'rid- o 1 di n an c'e s '-'50 v e r h ),',3 wo r k w 1 1 1. .''1Ye c o mpl i a 0 WI th , vihe t. 6 et,::,,,,s p :-; cf 14.-Iyel.4) n o r n o t: 1,..11-§ r a:00 ng 01• t h 1 s p e r tif t t I, d OP'4; no t:- p r es u mei- to g 1..V (t. a u ch Or'I. t y to - v lo 1 a r e or c a n c e` 1 ifye p r ov i s i onPof a ii .:v.-, o t h t-.1 r i tastator,1c,ca,,L, 1 (.911/S',r,,,..9,6,1 a t in 1,3 c o S:t. r,tit,i!,ct n ,irO h the p E. r to r m n ce's\ 0 f.:, 00 I''' k . ''' I a rli "€6C1r 1 z E.: d 'f.Y.'" s '6'n° rfior2.( a- 1ci co ht a . I n t h 1 a... L alyld , t,.., ..v.,..,,Y l'::,'? AT t e r i n 9 p.,sar,T1-t,,t).iiTh 1 s.,:. p e r mi t sha 1 1 b e c zinfe,:;:lnu,--1.1: an d v ovi d i f''.- t he; iWo r ,..:y'itl's not C 0 m m e n c e d 01 It h i n 180 da vs f r o m t the e d a r e". .6f/ ,I'S sr:0 aWde. -1D ' T t 11.e ..46 )- .,.. /.:.. suspended cibandoned,:f0P a period of:ioid tr..47r11 last-..Anspapicion. .,,-...., " THE APPLICANTMUST NOTIFY...THE CITY INSPlECTOP.:,,qr=, COrENCEMENT AND COMPLETION OF WORK AT LEAt 24 HOURS IN.. ADVANCE . 'FOR AN INSPECTION ..,CALL 43.?....0179. Signature: ; ,. . . - i. Date: /1:21.4/ -,•.-., . . 4*Ak4***4*4. k******4:****.. .. 4k'.-.*,.. ******4.*4 * ** * k: *.,:' * *kkk k******** ****** **44*I**44*4. 4 t4. APPROVED FOR ISSUANCE JAP " h,,,.,. ,:'...:-......, Issued By: ) , .., .1;i i 9. .e.ietsj. ,, .,''.' Dat..;:' ''''1-`-1- Authorized P e r m i , tf.1 0 r..-4 .t ',-e .. r..--S-., 1..: , 9 ,a tu .•„r. -.,1et...:: k k 1***44* 444k,k4 k0 ,i;A 444***444 4kk I hereby certify that the permit holder i;Inose name and address appears on this record has satisfaCtorily met the standards and conditions for this pro.;ect approved herein. Final Inspection Approved By: Inspector Signature Date. CI T OF TUKWILA Address: 4652 S 160 ST Permit No: PW94-0106 Suite: Tenant: MCNETT DAVE Type: PW-LA Parcel #: 222304-9105 S ta tus : ISSUED Applied: 08/2211994 Issued: 12/14/1994 ***9*AAkk****A*1,*4J,*44-4*44.444,44.*A44.1,4*444.44*44.4.4k*******4.4#‘4.4.4,0,4***4.0.40. Permit Conditions: 1 . Temporary eros on con tr:o;1:::,:nle.:5,i:tr.e•.s,S;I:i.'4:,,r;117.N,e, i nip 1 e men ted LAS t he f irst order of,AttSlipeSis.--t-Or prey tiTi i on off - s i te or into o mj d„r. ainaqe, faci The $ it e .h 114110ye p e tztma,i1 ej- o s control i . pl ace a$ so 0).1/4/4/.4•:';'.`p oc5s1 1:bei '.a71` to 111.,olatti;:.A S. 9r a rt'q s 41 comp 1 eted afi'd4r iors.kto„ the Y. i na 1 In speec t , 1 . Hauling o lery 50,- c s;'-'ks ha 1.1 r e qt.i'Vr69:1.AVP419 c 4 t i on.'" t,..asi a H :I. l9 :,,4, ,g,,,,I,V Permit.pt,:or to Apy,i:assptiated. activity, ...,, , • : ,,.-., c•:„. g .. 's, . .•.., Q, 1P—Kk,* 0 -pf0" ° ,4.1 O\ \tv :11,,o' , ,A , A 0 , :: ''' EZ • * I l' Ai, i ( '1;81 frl1 ... '1\ , \ "• `r \I; / • 1‘1, 41‘ Ab■;A'°8' ^X "(4;1 0 ■," 1", ,t0,4)•••\ 3/4„). Permit No: PW94•0107 Status: ISSUED Project: MCNETr SFP Site Address: 4652 S 160 ST Location: ON-SITE, NORTHERN Parcel #: 222304-9105 Wetlands: Sewer: Tom .DRAINGE Issued: 12/14/1994 Approval Letter: 09/01/1994 Expires: 06/12/1995 PORTION OF LOT Watercourse: Slopes: Water: Contractor License No. TENANT MCNETT DAVE OWNER PARSONS LORRAIN 4646 S 160 ST, TUKWJA, CONTACT MCNETT DAVE * .At * 99 4. 494 4 A A 4 At 44 49 44 41,4 11.4 * AfAse A , r . Additional Permit Dm5Apt.i n:' % INFILTRATION F.10,EM rCik UOWNSPuUTS Existing Square *ft.: tj, rd " " 4A,4,igiti New Square/.1Wt: o, sy 4.41 P4,92 UNKNOWN Phone: Phone: i206)246-5614 242-3279 t206)248-5614 444� * k k A. 4 h .4 44 Wk pf Inspectiot Fee: Plan CheciA ee: 1 . p 91\ N411' 4' \ t., .0 141 o ik A 0/11. c Atr.t. Nt. King CountyiliValuatiOn: ff. ,41V4 T.> e Constiuctiqp k kk 4.4,4 k k ki!!tA k * 4 4 A 44 h 4.4 itr* 4k k ,4 4)4 +1.* t k3rb h h I hereby 4.;,...ept thfis.!,permit-'and--,.agee City of TLikailAjlOiciPar-CodeWeagree,'tbatt.hetity of held harm.141: C,,l,a1Miarisfngs„,,a-V4'sult of Permits whfCb hLve lapsed -tiend,..the..,:piraifOn 4.0'te Shall re-applicWon ana,relssunce o1 the Oei7m1 t ti.:6-'2.c99h the Cit fee. , JO* .4 4,4fok!,t,k 1„0 ct) Tolcw11 at'in ,.., THE APPLICANT MUST NOTIFY THE CITY INSPECTOR',0E-.:COMMENCEMENT.AND• COMPLETION , OF WORK ATA.:,EAST '24 ';HOURS IN ADVANCE, :TO ,SCHEDULE AN IriSPECtION PLI_ -4( ,, i ,, 43-0179. '''','' C, '' , , ' . .s, ".,s4 •:.• ::" „•,'r •,'4••i **,40kA4-4 olF,rf the sh.00 be afv4 ad4Ational 0/1) .00 44444 Signature: .- A*A44414A**717*4t****40(4k• **JfkkAkklk:rkkkk APPROVED FOR ISSUANCE BYI:•.,W s.' 4 4 4 -4. 4 4 4 4 4 4 * 4 4 4 44,1k**Ar 4 4 4 e44 44;04 .( .4 * .4 4 4 4 4 4 4 k 4 4 : • '"•• •4.Y!--) ) Issued By: (1 cliQ2,-,,, ,,,, ::i—i, Date:j. ' Authorized P'e.i.:7A1;.tCenter .,",Fign4.u6eA',, ,..,-e:::=."....,.../ ..- I h t.lr e by cer t i f y t ha t the rce47;,,itil.:p.';;.1:1:0.er...,3111).Ths-e.,,-;;Ala":0V4,:nd' a dd i" e S t.r. i.i p pears on ,....!..,..... this record has satisfactorilyAlleialaWda,66d conditions for the project approved herein. 444.44**4*44494 414-44*4 Final Inspection Approved: Inspector Signature Date CITY OF TUKWILA Address: 4652 S 160 ST Suite: Tenant : ivICNETT DAVE Status: ISSUED Type : PW -SD App I led: 08/22/1994 Parcel #: 222304-9105 Issud: 12/14/1994 4 4 4 * *4 A* * k * * * * * .4 * .4* .4 4 .1.. * .4 .4 4 4 * * * 4 k -A * A 4 4 * '4* * * * * * .* * A * '44 * A ,4 4 44 .4 * 4 * .4 * A * * * .4 * * * * * * it Permit Conditions: 1 . Te m p o r a r y e r. o s i t.1 n c o n t ro,lf.:40e.a",pArtne.1.:(t;:%311,q,7z!Pic..,.... in I m e 11 t e ci a s ,.......,...7-:..z.:7,.-:._-,;:-....--t7.,...„..,, _ the 1 i r• s t o r de r o f. ftki,t.r-E-i:lie"."..::::::-.'t-O---FCr e v alit- -47e:d.f:li.):ra t i s i t e 0 Y" i tl C 0 e X t;$;,t411114.1ft 0 l'' Ilk dr i ri a 9.ei,:., f a o i 11 i;%..,..,.. 2 . A l l pr i v a t e s 5 i t i r f , f ; 2 : : a i n, WI. p e '41).',a 'I 'I ,itve e i t 11 e r' r e i ti 1 : o r- c : e d A Dcl.''''$.:=1' p e , ,'.1 'I, r) '''.i, iA V '('' • 4."44:''' "poi'," - cc • ■: ,, . • ■ . 4 sti/ * s .'s4,..,\:"■'‘,.. , '.‘..,c1• , ,: , , , ?,,,,,,,, , ,.• ., ,,i, . , 4c..: ,J,.a... l t, i. 0 :4 .1 , ,„,„, ,4 .',7..',I „ • N „, N,tI• . X Nk y .. . . ` 0 em . , , • r •,:r.,, 1 .. 0::.0 Xt-'°?” •• '''''',..1'..r '') • , ...0 .,,,..., .. ' •.,,, '4, il ■ h,ifyji 'Z41, 0 • i i' rit . *;;, i.,..1!..' tt.,„;,,, --.i.-- Ji.i:// .,:v .0`-' .c,...„ ,„0., .0 ,,..., 0 0 .... isr,r , • „t- . -•..,.-4, , ', i k; .- /' eri 4'"e•kg 0 ,44."-: ,.., '\'1.” 0 kVSt. 10). h.) el f P'.---'" ,..r, veti .,..."4. .4' ....••;-• ,,.,-----.. . v.,- ll r ,., ,..... ,..;;'; --....,, t..... it 4:■!, 1 ...4.;2:•'," 6 ''' ,,, .,4V 1•0•:,d. , :, , 0.•L'• J-1' ...._ 'p.., I J \ ,?,(i 1-1 :",,""•'' / 1 0, ,...- ... .-,'... . 1, r 4 ‘i, ,,. ,, ; "-- )'-- ' .4.1 ‘ . % o • '..:"..- , „it ,rc \ 4 1. ii "tifielk ..7,--..',7". I' Pk*,:k. . + ,I., ' 1 .,*" ./ i / ':'‘ ' .\ ■:,%, '"1„,•/, i I ,^1 '''",..\ .;*'-1.-,•'li('.--\•,T*....;44"174 , ty, orahr*..., ,, ,4, -4•0,5 , i"-- • . ID t t • A 't •l• —kt\ i°-1'45*''' :•, '' '•''S' , 1 ‘. 'w ‘ ot,-,- •,::, (0 1 ire'5 - ): Ns'N ‘..-.. , '''' \" .!.i 40 r 1 ''i. 4Zk •7 '- '4 'i.A),.?w, 1.s 7, ,,,,:•', •,,.. ::, .., '. . Permit PW94 -0107 c74' r 0* 4o, N 101. ,,, City of Tukwila • Application # • Cen r. P• .� Sys.. , t — Engineering Division �f ^ O O(Q 3 �' ter Blvd., Suite #100, Tukwila, WA 98188 Ph/ 9± _ Oda Ph one: (206) 433 -0179 PR E INFORMATION Property Owner: Street Address: Engineer: Street Address: UG 2 3 1994 UTILITY PERMIT APPLICATION pt TUKWILA Site Address: Name of Project: L 4s s DI' q .'.a.:� 1# i a. Phone No.: c2 6-(p ( Y Cit /State/Zi•• �L- /8 Contractor: Street Address: King Cty Assessor Acct #: PERMITS <`' > ❑ Channelization /Striping /Signing ❑ Sewer Main Extension Cl Private REQUESTED < ❑ Curb Cut/Access /Sidewalk YESXStorm Drainage - No.: Sizes: ❑ Street Use ❑ Water Main Extension ❑Private ❑ Public D Water Meter/ Exempt:- No.: — Sizes. Deduct ❑ Water Only ❑ ❑ Water Meter/ Permanent- No Sizes' ❑ ❑ Water Meter / Temporary: - No.: __ Sizes Phone No.: City /State /Zip: Phone No.: City /State/Zip: Contractor's License #: Exp. Date: 77 ❑ Fire Loop /Hydr. (main to vault) Flood Zone Control Hauling Land Altering 70 cubic yards (/° To /al Landscape Irrigation Moving an Oversized Load Est. start/end times. Date: Sanitary Side Sewer - No.: ❑ 0 jig 0 ❑ Public Estimated quantity. Schedule: ❑ Other: WATER; >:METE' DE POSIT / REFUND /BILLI .MORNTH LY <:SEVICE € `B1LUNGS ❑ Water Name: Phone No.: Street Address: City /State/Zip: Name: , L. m eljel- Street Address: /(,p /q qy{-4 Ate 5 ❑ Sewer ❑ Metro ❑ Standby Phone No.: . SiSc/ City /State /Zip: mgt 10A. 9 &b8 DESCRII PTI ON'OFPROJ E ❑ Multiple - Family Dwelling No. of Units: ❑ CommerciaVindustrial :;MISCELLANEOUS :INFORMATI: ❑ Hotel ❑ Motel ❑ Office ❑ Retail ® New Building Square Foot.ge: King County Assessor's valuation of existing structures: $ (l Single - Family Residential ❑ Duplex ❑ Triplex ❑ Warehouse ❑ Manufacturing ❑ Apartments ❑ Condominiums ❑ Church ❑ Hospital ❑ Other: ❑ School /College /University ❑ Other: ❑ Remodel/ Addition Square footage of original building space: Square footage of additional building space: Valuation of work to be done: $ r:aiEREB:r; CERTIFY .7- T I fAVE READ. TNIS APPLICATION AND KNOW THE' SAME TO:BE TRUE'AND CORRECT' Applicant /Authorized A. - i. n, r- • / ._ 11 _I Contact Person N, /�,� �, r r print name): & Ue I '{ �/f' ' Print Name: hAUID 4,, NIcic !ZI-r Address: /6,0i ? em, 40h S Simi-71R )A -1 / Date: et , i Phone: ,.� ; .- ,1. • VED Phone: _ ', Date Application Accepted: �2 4 ..._. Date Application Expires: 2 - as ._,11 PERMIT CENTER 04/22!92 M • k•k•k * * ** * * *•k *•k* * * * * * * ** * * * ** * * * *•k•k ** ** * * ** ** * * *•k ** ** * ** k * *•k * *•k * ** CITY OF TUKWILA, WA TRANSMIT **• k********•************* * ** * * ** * * ** * * * * *•k***** * * * * * *•k *•kilt * * * * *•k•k* TRANSMIT Number: 94001091. Amount: 520.33 08/22/94 16:22 Permit No: B94 -0305 Type: B -BUILD BUILDING P W,794 Parcel No: 222304 - 91051; Site Address: 4652 S 160 ST Payment Method: CHECK Notation: DAVID MCNETT Init: SAO *•k * * * ** * * * ** * * * * ** **•k * * * * * * * * ** k*** * * * * * * * * * * *•k** *•k ** * ** * * ** * * ** Account Code Description Paid. 000/345.830 PLAN CHECK - RES 520.33 Total (This Payment): 520.33 Total Fees: Total All Payments.: Balance: 1,325.33 520.33 805.00 'eu GENERA TOTAL CHECK CHANCE 4928A000 520.33 520.33 520.33 0.00 15:13 a/1 L I9y t'(' 6/ O ;k * * *k* le• ****k** **•** V****'k*h***** * *'k': A* ;1 * ****A**•A A *A'k** *k* *k•k**k** CITY OF TUKWIL.A, WA TRANSMIT ***k* Agri* h****k Ak**** h. J * -411.4tde Q5A**A****A**A*k*****.k******A- rromsmiT Number: 94()01.610 Amount: 37.50 12/14/94 13:27 Permit No: :PW94• -01O6 Type: PW-LA LAND ALTERING PERMIT Parcel No: 222304-9105 h i'te 'Address: .4632 S 16O "T Location: ON-SITE ,Payment Method: CHECK Notation: D.L.•MCNET•( CONS Init: BLS A*** 0..************4****AA****** �!**** * * * * * * * ** * * * * ** * * *•h** * * * * *, *** Paid 22.50 15.00 37.;0 'Account Code Description ia4 000/322.100 ` BUILDING -- RES 000/345.830 PLAN CHECK - RES Total (This Payment): Total Fees: 37.50 . Total All •Palyni rats: 37.50 . Baalarce: ..O() • ** 4kh* ** **a•A:k:4•hhA• * *4h *4 * *A** *4* k• A* 444*•***** 4** **4*4•*4*•4* **4 *•h c]:TY OF TUK.WI:LA, WA Cf (�- "7jO- 4hk:lhhk!rkA�hhhh!rkhhk 4!rh+h= s1�h•d•**�*t* • h` �i' ir- A*• 4*• h*• Ah •A•* *•,4***•A•h•k* **•*• * *•h* *4 TRANSMIT Number: 94001611 Amount: 25.00 12/14/94 13 :27 Permit No: PW94 -0.107 Type: PW-SD STORM ORAINAOE Parcel No: 222304••9105 Site Address: 4632 S 160 ST Location: OlN- -.SITE, NORTHERN PORTION OF LOT Payment Method: CHICK Notation: D.L. MCNETT CONS In ii t: SLO * 4 4** * **4 *4 *•*4it*4*it*•4fir.*h*** k4A *4 * *•h44•h *•* *44***••h *4 * * **.1 *4 •k444*• ** Account Code Description Paid 000/345.030 PLAN CHECK - UTILITY 10.00 412/342.400 XNSP FEE - STORM DRAIN 15.00 Total (This Payment) : 25.00 Total Fees: 25.00 Total All Payments: 25.0() Balance: »00 TRANSMIT / 8****++*+*+***+*+4*+*+a*^***A*++**+**A***++++***^4++N***w*+****.� CITY OF TUKN%LA ' NA TRANSMI T T *A****+*****.A+**+*A**A*k****A+A*+*+****A++f+**+++*+«*+++*+****+* TRANSMIT Number: 94001609 Amount: 825.00 12/14/94 13:26 Permit No: 894~0305 Type: 0-BUILD BUILDING PERMIT Parcel No: 222304~9105 Site Address: 4653 S 160 S. ' 'Payment Method:, CHECK Notation: D.L. MCNETT CONS Init: GLD ****++****+**A*k++*++++****»+^******+***A+**+*+kk*****++*++«++*+ Account Cade ` Description Paid 000/322.100. BUILDING - RES 000/341.703 'BUILDING - RADON MONITOR 4 9r<�h 000/306.904 • STATE .BUILDING SURCHARGE 4.50 • Total (This Payment): 825.00 Total Fees: 11345.33 Total All Payments: 1,345.33 Balance: .00 GENERA 800.50 CENERA 30°00 GENERA 4.50 GENERA 22.50 QENEQA 15"00 CENERA 10.00 CENERA ` 15°00 TOTAL 887.50 CHECK 887.50 CHANGE 0.00 8120A000 15:27 (:) INSPECTION RECORD • Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 r0 A : C Err REG. ype o ns • , . • :„.•;11252. s Iv) G.,...r. maim mr,I '171"r1 nstruct ons: Date anted: )O 0 - 2:7 -c9go .m. Requester: Phclne ': 2-L1qt. — 6101 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: • • • 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. - • ••• ■rt 'pate: ; INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ERM (206) 431 -3670 ole roje r F/ �' , PA-V in Address: r ;.: , , s , l' o 0 ;fir /'i:l/Il/I� 1 �f' V 6:teCalled: Special I2structions: 0 \.k v f q c ,5z) A. vw , Date Wanted: sb �I 9 s am. p.m. Requester: i‘lt, i 2 L W / `'f Approved per applicable codes. COMMENTS: ' O Corrections required prior to approval. ALi O $30.00 REINSPECTION FE = rQUIRED. •rior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ' 1 INSPECTION RECORD ti Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 X94 030,5 PERMIT NO. (206) 431 -3670 Project; G h t ti„Il. _ Type of Inspection; wj Address: ti 45 2 5. / (cO- Date Called; f_ 5 Special Instructions: .r - (,AS-r- Date Wanted: 5" S " C am p.m, Requester; Phone No.: Approved per applicable codes. COMMENTS: ❑ Corrections required prior to approval. Inspector: Date: 5 5/et/ ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 0 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Project: Yr C `' 'ripe of In 'on: l''' {hqii ATIBss 49.. S 166 51 Date Calle : (, Special Instructions: Date Wanted: am. .m. Requester: avi v' Phone No.: f ! `0 J" ` /z/ O Approved per applicable codes. Corrections required prior to approval. COMMENTS: • c..epL cam: 1 Inspector: /' Date: 5 /0. O $30.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule einspection. !e.a._.... _..aw.✓x'�s2t.'" S "5�1'�3:�E�1��- �2•••. ••.•xwdP,x. ,•r.. a• 8yid�Y ••�•�•,ad�iillli'c= ,rlr..�_ mss: eU.:ti�td2.'�t•Yfa::s.- = 'ii11�. INSPECTION RECORD Retain a copy with permit v CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT 0. (206) 431 -3670 ro ect :{lr , ici L1,- Type of Inspect 1-71A/A-3) bin vl Address: 0 � 5, / r^ 0 Date Called: Special Instructions: Date Wanted: c /z /Q / 1 Requester: `' Q Phone No.: r / .f4 ; C /(V 0 I J Approved per applicable codes. • Corrections required prior to approval. COMMENTS: 1.1.4 //7 S "k7 - / d _,.. ., i Ala (-r2H fir// �� cf,e,"/ /10b 1--- c.� fi"lr. J 1 I Inspector: t ,i AL / a-.' 1/ 4 i 4441. ❑ $30.00 REINSPECTION FE, REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No,: Dale: (0, INSPECTION RECORD Retain a copy with permit sPECT • 1 , 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ERMR (206) 431 -3670 Project: t ► `c let ! A‘it.d TypWRe nl:n(1 0(l'f 'i_eaf1 r Address,_. 165a S. ' v, St • Date Ca led: Instructions: ( 9--. i-h ∎ r1C_ ) c f INC Date Wanted: t " ' f ao /c15- •Special Requester: Phone No,: X Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: • ❑ $30.00 REINSPECTION F E REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD (1) Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 13q1-1- 0305 PERMIT NO. (206) 431 -3670 761 11 -r fi/ e /v t ype o nspectionpG'Yy \ t.t l Date Called: /g r cis i A rps:5 5 1 D s-T— Special Instructions: Date Wanted. —'...f. Requester: a'I v .-- �c9, Phone No.: ifs ❑ Approved per applicable codes. < Corrections required prior to approval. COMMENTS: 1. / L —'...f. ./ 14-7 , c. 4 i � 1, )?fit 6e. J vi r S y (�_i^ Y27 ' _s 5 rs?T h_e 4 %� Pd �. _�. �. .../ 71' ic./— cozi4'V Q— /d I / / Inspector: Date: Z- 1 0 $30.00 REINSPECTIO FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule relnspection. • • . _ •,...• N-t'y • O INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 (206) 4p1-3670 • Project: / 2 d.....,, ... .74.,—. Type of Inspection: ' . • ress:40,77-7,9‘. .a... // • ,,,, , Special Instructions: siL Date Wanted: 5 7.9d anf:-TIm—‘. , Requester: Phone No.: Approved per applicable codes. COMMENTS: I:1 Corrections required prior to approval. ffDA Inspector: o $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [Receipt No.:. • Dale: • ■ INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT (206) 431 -3670 —Project: i G I ' �T f N5Z Type of Inspection: 4_A 2 Address: q 6 S , / O Date Called: 2. r Special instructions: Date Wanted: �, 'L - ('O \ sytJfl j+•� Requester: �.jYus,. �f+� �J Phone No.: a.1 3.- , S(o r Approved per applicable codes. COMMENTS: ' A .4; ❑ $30.00 REINSPECTIO /FEE REQUIRED. Prior to reinspection, fee must be paid at. 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. ❑ Corrections required prior to approval. tD INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 ro ect: /)auz: K l SNP. fi/ Type of Inspection: o?.�� -Yk • d54-----' Address: -/� / V� 4 _ Date Called: // el , 9 -7.-r • Spedal'Instrucdons: d ( � c � jo• , ,, . ::: : . .- 95 am. m Phone No.: A v /et j ' KApproved per applicable codes. COMMENTS: ❑ Corrections required prior to approval. ❑ $30.00 REINSPECT! 4'1 FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Sulte 100.: Call to schedule reinspection. E. 0. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 77cl:4-1C--30,A,0 lib.,k,o_ Ty ot Cc... Address: te Called: Sp::a Instructions: Date anted: Requester Phone No.: - 1) 1 7)--..-3-6m( 0 Approved per applicable codes. f7 Corrections required prior to approval. COMMENTS: Inspector: Dat o .00 REINSPECTION F REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. •*"" * . At4k • • , City of Tukwila John W. Rants, Mayor Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Thomas P. Keefe, Fire Chief Permit No. if :1(/ . (3 C Project Name /I ` t M. :7 T / Ddo Address L/6 5 7,- /1(.f 0 1/ Retain current inspection schedule Needs shift inspection Suite # KApproved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM i/(//fi/er-- Date T.F.D. Form F.P. 85 eadquarters Station: 44.4 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575,4439 CITY OF TUKWILA Address: 4652 S 160 ST Suite: Tenant: MCNETT DAVID Type: 8-BUILD Parcel #: 222304-9105 Permit No: Status: Applied: Issued: B94-0305 ISSUED 08/22/1994 12/14/1994 *A*************************************A*AA************A***********k* Permit Conditions: - - - -, .,- 1. No changes will be made-tp,zthaT_p14s:00ess approved by the Tukwila Building Dly1S10,-- - . Plumbing permi ts:.:sile.11 be obtained through thiV3eatt 1 e-K ing County Department ,;;ef r4t,,ftc 14-e 41thiP lumb ing willi'be inspected by4Kit a,gei'IcSY 'iiic'il ud4 n'§ d 1) gap tp i ng \ Y''; (296-4722). 1,'&,,,,, .,.. 3. El ectr i cef4permttssha 1 1 be vd6t e 1 4 ed "throt.411t4es h' t 4.‘p n State Division' of 4.1700,: and I4d9,str i es ande 1 1 el e667,1 calk work w1Wbeeihspe'ctedt by t 4et \a4,eficy (248-630). 4. Al 1 mec4an i ca 1 WbrKwsha 11 be nder 'separate per'mi el siued 'p4, '.4. , the Cftt of Tukwi ta. ,",.. ',,-,- -, , , , , \,.,. '-' ' '4',„-'' W 5. All iw o ts.,Iii inspection :. i'ecord/s , _an 'd approved p 1 ads 34el•f be,,v, avaitre$10,at.,-the Job site pri6t--to the start of any,, cdprr„, 0 , str4klio4. These docUibents- are to W maintained and 4 t' a vKwa7- .l- , 1,7 a b 1 6 Iin t 114fi 41 i npept nn kro yak 4S"g rAn t d 6. Engyered truss Oawing 31 cthu1Iei44s-Shall be on sIre 1a1'tr'1,/0 ,, ii t andai laNle ;:to'the:bu,ii,diifp iris0qtrfor J;inspect io4 pu s esboounients" sh61116ear the S a 1-: arid' signature �U' a,j W a 414 g t 94, 6State ': pi- o f e si o#:(Eng i fi'v el= .-'''' f 7. A 1 1 rconstruction t Ci,;b be dron e,/,i-ii "cpn'f!;Kman‘cev'W.1 with approved 4 pla sA. and requl remeifes ,.,6' fr,,t he On tf arm.4autrd tng Code (1991 1 Ed i eqki ) ks p mon d e d , Uniform Me 04 a(4 i ;a 1 code -44 991 cd i tkpuX, and 'Ii!ktlhivigjan State Energy Code ‘0,4 40,10.919- q:' '4'41.- I: 8. Therf..,ha 1114 no occupancy of the byf \dithg(S ) funt l the o,'Ifl i. f ina 1 '111,04et1 on has been comp i etod /by MierTukivi la' Bu ti'd i ng,Mq 40. :, / ( I \ i ','4" z' 144 Inspe \ , , i 4 ' ' - , i i' N' 9. Val idi txpf Permit. :',The issuance- of at,permtt'i* approva 1 ':)f. plans, seyc if i c01,ons And computations shall 'not,p* co4,7, s trued to:, 00,, a *),,i t f�. an approve] , cif, anyl o 1 a tjicri of any of the prov is i ons of ' the bui 1 dtng code or.-�f cTsf,/ other ordinance of the Jurisdi ct i on . No permit pres,0449 to give authori fY.'40 .violate orciricer the provision,s:Aifthis code sha 1 I be valid. ":"."' • •-•. •, w�wwr ...rwmin��n...r...........WW. wow. rw. wwu' M. k+ AMw nMrww+n.wtavnvr.en.remWVM:,e.r: pMhr+ MN.nraYwN�++L'4i\'wi :fSMaJ.ir[m es. r�' �. Pra. u. a.,ran....n.....iw.....rvrnr.nV r..w+�u.N W.Y•n.i+LYr -*AO- *8?4.o?o6 DECK DETAILS SUPPORT STRUCTURE All wood components will be treated or cedar. All nails and fasteners will be galvanized. 4 x 4 posts with concrete peers and saddles on compacted ground. 4 x 8 beam supported by posts 8' o.c. Deck rim to be lag bolted to house 2' o.c. 2 x 8 ,joists 16" o.c. with rim joist, solid blocking at beam line. Cedar decking 1 x 4 or better nailed. Guard rail 4 iri 4 posts with top and bottom rail, pickets 4" o.c. 42" high. Stairs (if any) will be 2 x 12 with hand rails. ALL MATERIALS AND CONSTRUCTIO,NIS TO BE PER CODE. 1 ern Con ,00' SL ,I. 1 r■,,917 43c, 088 N 1 0 d31N3O 11W»;id 47661 z JRV V1IIWffii AO 4110 03AI303U onend w 0 1 0 2 nn iW 0 N 0 0 A 9.Q CALLOUT ITEM LEGEND: SITE PLAN 0 rri 00 z 612i . 84.01 M„Id,tb w1 8 1`4 Nag ?r1"1113•WM .0e) • S,� PSI 31$ seme gerS.2 S. /6o/1, tau 0 484 Detic x ae� 1 �. NoPesxt• NEB \. kessoeNte RECEIVE AUG 2 3 1994 6 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA AUG 2: 2 1994 PERMIT, CENTER SELow° bMP Cr \ plaits h a en reViewTad ,by thy Public W t bep m t f r conform4ftce ith current City standards Ac eptance is subject errors and omissions do not autl ize viol$tions of ORk d &' tandar ordinance: �:. esp )nsibility for the adequa of thee desigr: esis ioi Ily with 1Rj the designer. A itiong..,deletio or revisions to CA these drawin E after this da will v� id this "` acceptance &ddav�i+II requirq subrnOttal o'f itiryised dr ing aefor subseqbe, t approwal. Fins too is b$!� to Saki 611 ge: Works uti�w e�i I. RECEIVED • SE' 1 41994 Guivimuivi 1 Y DEVELOPMENT Sirk PLA4 (t"' 4' 8'xo.,o1 kiPosI.D NEE W \ Ras1DFNcE \ \ 16" Ori7 \a SES° �tHA W 4 1JNe \ o� \ —2o 4' 4' \ ;Tit:\ 7a 0 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #B94 -0305 (510) Re: McNett, David - 4652 South 160th Dear Sir: John W. Rants, Mayor September 8, 1994 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Every building shall be accessible to Fire Department apparatus by way of access roadways with all- weather driving surface of not less than 20' wide and 13'6" vertical clearance. Access roads in excess of 150' shall be provided with an approved turn - around area. Access shall be within 150' of all portions of the buildings. (UFC 10.203,204 as amended) All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (UFC 10.203, 204 as amended) 2. For short plat development (four single family homes or less), hydrants shall be placed so that a hydrant is within 250 feet of a building. Distance from a hydrant to a building is measured along the path of vehicular travel. Fire hydrants shall conform to American Water Works Association specifications C- 502 -54; it shall be compression type, equipped with two 2 1/2" N.S.T. hose ports and one 5" Storz pumper discharge port, and shall have a 1 1/4" Pentagon open -lift operating nut. 3. An approved residential fire sprinkler system may be installed when vehicular travel distance from the nearest hydrant exceeds maximum distance allowed. City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1646) Acceptance of residential fire sprinkler systems shall include field verification of GPM and residual pressures meeting or exceeding the listing for the sprinkler type. 4. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 10.301(a)) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc T.F.D. file ncd John W. Rants, Mayor NOTIFICATION OF UTILITY PERMIT ACTION TO: PERMIT CENTER FROM: PUBLIC WORKS ENGINEERIN c DATE: SEPTEMBER 1, 1994 SUBJECT: McNett Single Family Residence 4652 South 160th Street Project No. P94 -0063 Activity Nos. PW94 -0106 and 0107 Contact Person: Dave McNett Phone No. (206)248 -5614 Ca.&c. 01494 10 Ross A. Earnst, P. E., Director THE FOLLOWING PUBLIC WORKS PERMITS HAVE BEEN APPROVED FOR ISSUANCE IN ACCORDANCE WITH THE PLANS APPROVED ON SEPTEMBER 1, 1994: Land Altering Storm Drainage Permit Fee $ 37.50 25.00 TOTAL $ 62.50 Two copies of the confirmed Utility Permit Application Form and approved plan are attached for inclusion in the permit files. JAP /jap Attachments a/s cf: PW Inspector (w /copy of application /plans) Development File (w /copy of application /plans) 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433-0179 • Fax (206) 4313665 VINO City of Tukwila Department of Public Works John W. Rants, Mayor NOTIFICATION TO RECIPIENTS OF PUBLIC WORKS UTILITY PERMITS Ross A. Earnst, P. E., Director All Public Works utility permits have a standard requirement listed on the first sheet: "THE APPLICANT MUST NOTIFY THE CITY INSPECTOR OF COMMENCEMENT AND COMPLETION OF WORK AT LEAST 24 HOURS IN ADVANCE. FOR AN INSPECTION CALL 433 - 0179." This is being emphasized and brought to your attention due to an increasing number of developments where this action is not occurring. In some cases, construction has not been completed in accordance with permit conditions and City standards. In situations where required notification has not been given to the City Inspector, the developer is proceeding at his own risk and may be required to remove and replace nonconforming construction. You are urged to review each permit and set of approved plans thoroughly and comply with any conditions or requirements stipulated. For clarification, the City Inspector referred to above is the PUBLIC WORKS UTILITIES INSPECTOR, GREG VILLANUEVA, WHO CAN BE REACHED AT THE 433 -0179 NUMBER. Your cooperation in this matter is required and appreciated. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433.0179 Fax (206) 4313665 ��": r, yT, „Hll,� y;' ;J ' ..; rlAyr .. r� .,,, ,,. .v l? 'r '... t ( i 9, ti ., P ;14 ' " t I 4.%` RYI:•Y.)1J S�'..N:i ry'r.: 'p •b': `"(NfA ,}• { th`? : « 7 g' r 1; �•.ti 1 : ;4k1!" A' z,.91 . ....,..,,,f,.;,-,•;? .',;1 :t,.' !r ; '' � . : PIR) A ry 0 uo n. s e a., ? t pVi } �i ti•,.'''S .4.0, Z!•. 'f i (( . 'P` iS, ,; ;' i •.) 'F 1 rS t1 N ; y4 h ; ' :.,: ot�%. +•4 'l, ) .Y 1 . K . i t• , * .; ,1."MM t. ; M .k ;1' .i �S r '�• t�i : r r ! , ,• • , {:„ 'n. ,,. � .i. , f ' I !,y m. »4+r■ .,.: t. a• .7 tr ' , t'', ' :Y+. ' .8 t. G J ri # t . .;•i ,� r, i 1 • ' stt. .- ' V. 11 t y,'). , , r;;rd-.:%; t � '4. ' ,;, e ; • ,.. > .. :� '• f , C SIGNATURE ISSUED BY DEPARTMENT OF LABOR AND INDUSTRIES 9404110450 R 111994 APPLICATION MMUNITY CITY OF TUKWILA DEPARTMENT OF COMMUNITY thcen?er Boulevard, Tukwila, WA 98188 Telephone: (206) 431•3680 APPLICANT Name: Loz2.A1).1 Pke_soms gvrAt, 33S Address: 4(04-6 Sown-1 1 bin4 • sTRE-...1.-7- City: TIAKWIL O. 6, Signature. .../..1_4.1.4 4 %i 15?) Phone: LOCATION Street Address: 4( 4-14. S 0,71-1 11.70 • STESEr y-tW(L WA. 9'fi 1 55 Date: 3-24c3 t, indicate lot(s), block and subdivision; or tax lot raimber, access street, and intersection. S E, Zoning District Existing Use Proposed Use Proposed Lot Size 22. 2.3 1\1 4 siw.v. QUARTER SECTION TOWNSHIP RANGE 1)C1q7111(:) \ D9) A 91(t) DATE OF LAST PLAT: (1, ot.d t-eSSeS a, vet.. I 4- /5 •:(p • • . , : .•: • ••• ...•• • • • • • •••.• 1:1 • • , • • • .• '" ' ' • • . , ..i 1.....:::,,;......, 2. ji,;.. 7 ,.•.,.: ,•'. . . .. •• -1... .1.-0...i1;.,,,,k,!;:111:„. [Li...11;4'61'4'47:41f1 ...:..., ;... ''. '• ... -1.1,.ii•i ..:0..11:.•.:•;'...."' ', ''1:.1":',.?:1 ;PI:: .'• : •',...t, . ',• ' ''"! :: '7:•..,'..•.: 4. •:•%..:...7..'::.*-7..,4).... ,•'• ....:. •••• • • • . . . PIRMIT 004110,1 ' R- l - 71 p_.,..1... -iz . 2-1-7Z. R'esn:=,eAlcE Re.S.lbehICCS RGS.ThE ',K.-C. g'511_,EIJCE: -6S ! C1JC..€ 2.0,400 10 ,2.00 000 9 S so DATE OF LAST PLAT: (1, ot.d t-eSSeS a, vet.. I 4- /5 •:(p • • . , : .•: • ••• ...•• • • • • • •••.• 1:1 • • , • • • .• '" ' ' • • . , ..i 1.....:::,,;......, 2. ji,;.. 7 ,.•.,.: ,•'. . . .. •• -1... .1.-0...i1;.,,,,k,!;:111:„. [Li...11;4'61'4'47:41f1 ...:..., ;... ''. '• ... -1.1,.ii•i ..:0..11:.•.:•;'...."' ', ''1:.1":',.?:1 ;PI:: .'• : •',...t, . ',• ' ''"! :: '7:•..,'..•.: 4. •:•%..:...7..'::.*-7..,4).... ,•'• ....:. •••• • • • . . . PIRMIT 004110,1 ' IT PLAT NUMBER 256 m — , /.. ,_ITY OF TUKWILA, WASHII*61 �N LEGAL DESCRIPTIONS BEFORE THE SHORT SUBDIVISION: The west half of the southeast quarter of the southwest quarter of the southeast quarter of the southeast quarter of Section 22, Township 23 North, Range.4 East, W.M., in King County, Washington; EXCEPT the south 30 feet thereof (shown as unplatted Tract 54 on Sunnydale Gardens, Division No. 1), according to the plat thereof recorded in Volume 25 of Plats, page'50, in King County, Washington; TOGETHER WITH the east 5 feet of the southeast quarter of the southwest quarter of the southwest quarter of the southeast quarter of the'southeast quarter of Section 22, Township 23 North, Range 4 East, W.M., in King County, Washington; EXCEPT County Road. AFTER THE SHORT SUBDIVISION: v,E ,4- fi/4t-Gfr` . This space reserved for recorder's use Return to: Dept. of Community Development Planning Division City of Tukwila 6300 Southcenter Boulevard Tukwila, Washington 98188 • APPROVAL Reviewed and approved by the Short Subdivision Committee d hereby certi- fied for filing s��day of ,19f''f" . Chairman, Short Subdivision Committee DEPARTMENT OF ASSESSMENTS Examined and approved this // day of ,19 /5‹ 5E s r it /cu: Assessor Deputy Assessor -zg 3u '• I "y+r' Page / of 8- ■ 1" • COTE :` 1.) "Sprinkler systems `Lich meet City codes must be appro;ii prior to issuance of building permits for any home located more than 250' from a fire hydr E " E Iv EQ 2.) "Due to soil conditions on site, storm drainage will 281994 be addressed through infiltration." Ck.;wtivtuNtTY DEVELOPMENT ul a a- 0 85 1.88 °42.4rt 169, 73 20,400 SPEY• 0 ••CAL . 1 ' 7-50 .. 12' ALL WEATHER .GRAVEL. SURFACE CAPABLE of StAPFO .1Th Ci 5.0,000 LB. 11 v X - -- -3D� PRIvkEE 'ROAD Y146 f~. ss. MGR S. U-'r rty to- 31. Gi H2O METERS N €386.4211-1v4 .%Q.H20 •• ?grar i027ZIOZZliatary iraVIVI71i�7 it //141r 1 ' GAS 63"PvC.. SEw5.2:IA .8_W Wei R..M►14.J PxoPo5E1) 4i3" MANHOLE ~.; 3:_. ",SERV1G]✓.�- 1 ►�Cc. '1',4P1✓D INTO 8" MAW EXIST1'NG G" Pv.0 S 01..) S;16 Land Surveyor's Certificate:. This Short Plat correctly represents a survey made by me or under my direction in conformance with the requiremen ts of ap- pro r riate State statute . d has been properly staked: s. .,� f , e, Name: Date' Certificate No. S3 4 Short Plat Number 3- be 'O 1 EXPIRES . 2 --5- Map on File in Vault Direction: • Scale: 1" =-'50' Stamp: TRACT "D" 5.. / 4 c .±' That portion of the West half of the Southeast quarter of the Southwest quarter of the Southeast quarter of the Southeast quarter of Section 22, Township 23 North, Range 4 East, W.M.., in King County, Washington described as follows; Beginning at a point on the East line of said subdivision which bears North 0 °49137" East 215,00 feet from the Southeast corner thereof; Thence North 8842'41" West 56,72 feet parallel with the South line of said subdivision; Thence North 43'42'41" West 46.96 feet; Thence North 0'49137" East 81.52 feet to the North line of said subdivision. Thence South 88 °38'45" East 89.66 feet to the Northeast corner thereof; Thence South 0 °49'37" West 114.63 feet to the Point of Beginning. Subject to and together with an easement for ingress, egress and utilities over, under and across that portion of the West half of the Southeast quarter of the Southwest quarter of the.Southeast quarter of the Southeast quarter of Section 22, Township'23 North, Range 4 East, W.M., in King County, Washington described as follows; Beginning .at a point. on the East line of said subdivision which bears North 0°49'37" East 30.00 feet from the Southeast corner thereof; Thence North 0 °49'37" East 255.00 feet; Thence North 89 °10'23" West 20,00 feet; Thence South 0 °49'37" West 24,01 feet to a point of curve from which the radial center bears North 89 °10'23" West 40.50 feet; Thence Southwesterly along°the arc of said curve concave to the right 63.94 feet through a central angle of 90 27'42 "; Thence North 88 °42'41" West 24.13 feet; Thence South 1 °17'19' West 20.00 feet; Thence South 88°42'41" East 14.95 feet to a point of curve from which the radial center bears South 1 °17'19" West 40.50 feet; Thence Southeasterly along the arc of said curve concave to the right 63.29 feet through a central angle of 89°32'18"; Thence South 0 049137" West 104,62 feet to a point of curve from which the radial center bears North 89 °10'23" West 25.00 feet; Thence Southwesterly along the arc of said curve concave to the right 39.47 feet to a cusp of curve; Thence South 88 °42'41" East 55,20 feet to the Point of Beginning, ALSO: The North 10.00 feet of the South 40,00 feet of the East 70 feet of said subdivision. NORTHSHORE LAND SURVEYING 19706 80th. Ave. N.E. Bothell, Washington 98011 (206) 4834020 111 111111 'IIIII IIIIII •IM/ IINIIYfIllu., /111111 Ill• °wow 1.4 plll rylIIIII I,OI I/III11111111`, A JOINT MAINTENANCE AGREEMENT Notice is hereby given that G;2,. owners of the following described tracts o(land; Parcel "A" legal attached as part of this subdivision. Parcel "B" legal attached as part of this subdivision. Parcel "C" legal attached as part of this subdivision. Parcel "D" legal attached as part of this subdivision. do hereby establish this agreement and convey unto all present and future owners, their heirs and assigns, of all or any of the foregoing described tract of land. The maintenance of the easement granted and conveyed in short subdivision of City of Tukwila No. L93 -0022. This agreement shall be binding upon all present and future owners of the parcels created under the aforementioned document. 1. Sewer line: It is agreed the 2" by 4" lines shall be the responsibility of the individual owner and the 6" line shall be the joint responsibility of all parties to pay the cost of any repair or maintenance. 2. Easement Roadway: It is agreed the costs of keeping the easement roadway for ingress and egress in a state of good repair and generally attractive condition and shall be the responsibility of the owners of the parcels A, B, C, and D. MAR 1 01994 C /."IVIS4.• \1 � 0 E\ /i�OP1V=N Y 2-''3 -c0-1-P- 7624' DECLARATION: Know all men by these presents that we, the undersigned, owner(s) in fee simple and /or contract purchaser(s) of the land herein described do hereby make a short subdiyision thereof Pursuant tg i W 66.17.660 and acknowledge that said subdivision shall not be further divided in any manner within a period of five years, from date of record, without the filing of a final plat. The undersigned further declare this short plat to be the graphic representation of said short subdivision and the same is made with the free consent and in accordance.with the desire of the owner(s). In witness whereof we have set our hands and seals. Name. * -e Name: Name' Name. Name. Name: Name. Name. STATE OF WASHINGTON County of King On this day personally appeared before me to me known to be the individual de ibed in and who execut d the within and foregoing in- strument, and acknowledge that signed the same asc.'vfree and voluntary act and deed, for the uses and purposes therein mentioned. GIVEN under my hand and official seal this 4!� /day of !" ,19 Notary Public i4 - d for e tate'of W n on, residin _ at ► .. . STATE OF WASHINGTON County,of King On this day personally appeared before me to me known to be the individual described in and who executed the within and foregoing in- strument, and acknowledge that signed the same as free and voluntary act and deed, for the uses and purposes therein mentioned. GIVEN under my hand and official seal this day of , 19 Short Plat Number La ? —OG 22 Notary Public in and for the State of Washington, 'residing at Page of 7 • • w REVISIONS 10 NOWANGSMALL THE sOOPE OP WORK WITHOUT PRIOR APPROVAL OF TUKWILA IltNLDING DIVISION. NORM REVISIONS WAL REQUIRE A NEW PIAN SUBMITTAL AND MAY INCLUDE ADDRIONAL PLAN REVIEW FEES. • GENERA. NOTES • All work to comply with Uniform Building Cods, 1991 Edition and all applicable Nuchanicil, Electrical i Ensrgy•Codss. • .Contractor shell verify all site condi• tions and building dimensions prior to proceeding With the work. Any variation from conditions end dlmansions shown on the drawing shall bs reported to the. designer for resolution prior to con» struction, otherwise contractor shall be solely responsible for costs of any necessary remedial work. Written dimensions shall have precedence over scaled dimensions.. • Do not scale these drawings for ctitiei dinnsions. • This office assumes no responsibility as to the physical dlraoteristics of the soil, nor doss this office verity the accuracy of the engineering dots supplied by others. • Assumed midimwm soil bearing value 2000 lbs./aq. ft. • assign Load Conditions: Roof floor 25 10 350/sq. 45 10 550/sq. • All joists and rafters shall be MERiFIR 02 or better. ft. ft. All sawn beams, headers, lintels Girders: 40 nominal shall bs 001041R&LARCM 02 or better V nominal shall be 000G•f'IR/LARCM•01 or better. • All glued/laminated timbers shell by OOUG4FIR/LANL:M. • All wood exposed to weather, such ss Solt freeing, decking, failings, joists, sus i poata shell be pressure trsetad • e Sr. -. r REAR ELEV. PAVE COPY 1 understand that the Plan Check appovds em subject to ernes and adobe and approval of plans doss not sale r ISN of any adopted dada or S1S N a aoaraotOt a Copy Cr approvnliessa . ,4 Oss- /V7:::21 Tor n ctiInr4t.r Ms) T bR Z =e' AG10'e ANY ROF */inure! ► o -eon. eve FikLF Rota .112 IZ r we„ SEPARATE PERMIT REQUIRED FOR: &MECHANICAL itILECTRICAL ISWMBING VAS PIPING CITY OF TUKWILA BUILDING ONIWON I2 • t.. • • LEFT ELEV. 1/13" 5NER9 r CODE DATA ? `� It* PUMA ALA eq MAMMA • : s. rtt.. s as KA TO MAO ff • awls . s',r- iS G S�NC8 Swap glamy ane = 2 * NMArrcv rt.gum Aao.4 genius = O. b5' alt S77fl, MLi is at warms glass to to mile ; of Aib l tAkict Can MININUN BUILDING INSULATION *roof R•301.0 •Not water pipe *enactor *Not water heater well R•19.0 *Ducts (unheated *framed space) R.4.0 floor R•14.0 *slab floor (T1• 0 pert. ester) R•S•Oit•1 O • `i *Allow min 10 air specs over insul4tion when batts are weed between ratters. 11 wall • roof insulation applied directly to Interior fleeing smash shell be provided with a awn, Osrrlst on heated Bide. *All showers is 1mvs control for sl%3 cps . flow. 1/2" 11.16.0 Verb RTI. 2.4p L01•KeE¢EC, sollretv4T. . "Min •, Z :'EAKC. 12 CITY OF TUKWILA APPROVED SEP 194994 A� BUILDING DIVISION ZG*tl2H•'4 • 'f-11! I w4 cena4eA fc rtL c, &Rb = 1p04C,t • .%• IDxta 4L4t1Plf ' �1 OTIV T AU8 2 21994 saw ant • I.1 • ELEVATION ,,,�" . ,s.," e V. • • r tams= 1. Mihimum Moil bearing value 2000 lbs. /s.f. Foundation footings shell be placed upon firm, natural soil. Number Wall• Lieffl This 2 8" 3 10" All concrete balls 6" above grads. Footing hits 171576 16 "x 8" minimum Min. Below 17 act 18" 24" 3. Minimum reinforcing steal required for foundation walla: 2 • /flare in footing 2 • #4 bars at top of wall 4. Cover soil throughout crawl space with b. mil vapor barrier -••lap 1100" at each joint and extend up foundation wall to outside grade line. 5. 18" min. crawl specs under joints and beams spaced to 5'; 12" under beans and girders more than 5'o.c. 6. Crawl space access unobstructed, min. 18" x 24 ". 7. Foundation ventilation-Min. 1 B.f. for every 150 e.f. of crawl specs area. . 8. Provide 90/ felt between footing and post. 9. Post to beam connections shall be provided with a positive direct connoction to oaaura against up- lift and lateral displacement. 10. Wood members entering masonry or concrete require 1/2" net air space on tops, aides and ends. 11. Columns & Poste: Project plinth 2" above conc. floor, or equiv., (6" above earth) and anchor. 1i. I'lud Sills pressure treated, 6" above grade; anchor bolts 1/2" x10; 1- story -6' o.c., 2- story d o.c., and 3- story- 4'o.c. anti within 1' or plate nncls 4 *Where. 13. For conventional construction and • bearing wood to metal and wood to wood joists, 1 -1/2" min.; wood to masonry or concrete, joists 3" min. beams b /or stringers 3" min., splices over supports shall be adequately tied. 14. Double joists under parallel bearing partitions. 15. Header joists more than b' lung and /or tail joists more than 12' long shall be supported by Framing anchors unless bearing on a beam, partition or wall. 16. Solid blocking over bearing partt- tions, walla and beans. A. lauCe Mat 'vre . Min Plra /ato'tar y GONG. S a 1..'(2'4 "x 1 011 GONG. PTA • p!, ax4 syr sv s . nirr f°I4 y clot p •/ COQ. rt.INTS y I b''x 1 b'' x 10' COWL • fratA • 4. 4)0 Paver rico* FELT V 144 a4 ,i to Goat. • --I Leo 1 *tog • I,1�.l.O11 • vice • Y .. . • • a00u 0 '7 I Zt•O" 00.011 afg N all o° M I ht • (2! lO.O TPeel MI~TEC I•41.10C .v • GONG .. Ab •/ o f MIL. ,1/Ate a:A. •/ GOMPfrCT O 42Averta. f•IIIJ . 16)( 24 Gf meat. bttA $. Mt (NY v �•2,, N 3 0 • 4., l o,, el :BA f Altb c1 .0' I sty* l0F '- 1 cox%Zgr1* I(J,F. it xl2 2M#IOF• Ads . .. 1 2' Ito ✓M 71-; ►1 �• en 2 ilde=1b4 -111 RAUIL. • a, (7Gostmag" 6t. sit tr • •F� � AT C 1 as. gap a "ar Ja 4sap lb FM'S. Wes. 'tgso4015Rt es, IIaUO.G• 4 N • Oleg - 41141&8E IOC • SAM • o t �s M MR 1: n Ma . _ . _ • •• i • • • • • • et I• Wi_r 0 ta 4 al • 1 Wrie►T SWWuto4ct t< cAm-Vt Lest& 13411emos e %an "WO ° 1&°4911 1 _l (I I 4%0" lr IO'i! I�O''4014Jr14 0/ CONC. 4:1.I•4114 •/ t 'x 2'} "X • d° G4NL. PTA, , MIr.l.4 "coNc.POr�cH elLAID A %Teti% 1v/ ex rysz M'S • Ft 14 . • • • - - . .. - swain -0 Enna glum Armes 0178 It- CteSat enema raw stns.. _0 ej "G9NG. eefIU •/ GoMPACTw at4 . tov01` 1 1 1 1 1 f�• %11 JP 2O ;o" BUILDING DIVIS ON Low a FoUNbAtIoN PLAN ,,,u.r_w MOM CRY or YUMA AUG 22 % MAW NM 1255 SQ. n. • . • I. A:- ,ri •■• "in, _., °fete'' i $t' •.rii7sas1J ti e ;/ "' !kr T: . 'I• • ;$142:14W4 • N r'. ,'�" � :: • �! ' • tit ' r • 1 ' l• . 4 '1I Xt1 1 • ' ''I • • V . I fl F • N, '1 • .. 2. Mese within le of floor and gnstar then 10" in least dimple lion shall be safety glass. 3. Oath, laundry, and similar rooms minimum exterior opening 1/20 floor area with minimum 1.1/2 s.f. or mechanical ventilation dir- ictly to outside capable of 5 air changes per hour. 4. Clothes dryers shall be exhausted to the outside: kitchen hood, laundry and bath exhaust fans shall Os vented to the outside. S. In every sleeping room provide en emergency exit window with min. height 24" & min. width 20" and not less than 5.7 s.r. operable area and not more than 44" from floor to sill. ' cp DINETTE 'b410 Pit 1 6. rite Warning System: Every dwell- ing shell be provided With approved detectors or products or combustion other than heat, mounted on the ceiling or wall at a point cen- trally located in the corridor or areas giving access to rooms used for sleeping purposes i se approved by the building official. 7. Tile for shower shall be 6' from floor with non- abaorbent surface with water resistant backing. 8. Shower enclosures shell be provided with tempered or laminated safety glass or shatter resistant plastic. Hinged shower door she'll open outward. 9. Garage house occupancy separation min. 1 hr. taped d finished. 10. Doors between garage d residence to be 1 -3 /S" solid core with self - closing device. There shall be no openings between garage d rooms used for sleeping. 11. Appliances Installed In Garages: A. Shell be suitable protected against damage. B. Appliances generating a glow, spark or flame shall have pilots, burners, or heating elements b switches min. 18" above floor level. C. Where the furnace and /or ductwork is installed within 12" of the wall, the G.W.B. shall be installed before placing the furnace and /or duct cork. 12. Heating unit to maintain 70° F. W 3' above floor when 10° F. outside temperature. 13. fire damper ducts piercing sepa- ration wall between garage 4 residence or provide min. 26 Ga. galvanized steel ducts. 4r' .1. OfT'oNAL *icon cdTovL 44/ 3RICK 14 keToi 1 -MR St- Net c•fUcEsLEp ter /hat GEILIN CI 4 is FAMILY ROOM ti MSTR. BEDROOM assessa .. • ..-.,.- .• Sins, .._._ .a ,. - -_- ..r.+.. -. 2E FEt. • 1 �..e.•1l.Lr /•u '• v.. bnE1.F • * ROP no 0' beest- Mine 044 • 5111 '9btbNN R•16 4'VAlw .,Tset 01 et4 1.-IN, 14(2; 1 • Ws' T� ----► To ,-■ a u.L. approved 'ter 20" deep ran -cutup. combustion air via .GJ 1 A'N., TS - clearance F.P. w/ hearth & outside 6 sq. in. vt V-Lei es 1 io xio1 e. er- k c/a" -.YFE 1 )C' cR - -- 2t�r` r* r;T'1 t . ICs t2 `•19'. DOUBLE GARAGE d4 aGCl14G r i$L S% 0/ COM PACT :O RSV rri sore Ori ��`•. i4. ALL --n4 t sHo'a tZ %must. 1" A. i'icaessoc {<. MeT■•iEIEL.! STt..tz: r■ 13 L M IT ' 'f F:Los..• orb NIA x G . N.44 I✓1• vA 1 $ .r, M I r.-1 ,©" f rada e 1 :1 .4G {;_ 1; M ALL GL.A7_►LJC.f • I1.1GLuZ'=1U • •••uL'�Jrr5, \ ATfttJ 610" oft •HJ I1..4L.>= -, :PILL. o5os Se NM.? Ro,.>4 o ./ n) r • V ti • 1(9!.o" 4140id' 49 2 J. M. Di.. L' +_,. ELOoR PLAN !M".,• _o.. • • • Guam itegir CITY 0 TUKWILA AP"OVEO SEP 9194 AS O 11 BUILDIN DI • SION • OW OP TUKWILA AM 2 21994 paw fl I Ili I SQ. FT. - DWELLING 440 SQ. par IS GARAGE • arc r� gam Trusses' Stress analysis i details with drawings stamped by an approved state of Washington registered engineer. Girder Trusses; Analysis t details shell be admitted to building di- vision for approval. All roof trusses shall be so framed Al tied into the frame work and supporting wells so as to Fora en integral part of the whole building. Roof trusses shall have oints well fitted and shall have all tension members well tightened before any load is plsodd upon the truss. Diagonal and sway bracing shall bo used to brava all roof trusses. Roof bracing to bearing well. Attic Ventilations Net free area 1/150 of attic ores or 1/300 if 1/1 is in soffit and 1/2 is 3' above plats line. Approved roof sheathing min. 1" nominal wood, or plywood roof sheathing sham be bonded by intermediate or exterior glue. Sheathing nailing 6" o.c. at panel edges and boundary members and 12" o.c. at intermediate supports. Plywood exposed to weather shall be CC exterior. Asphalt shingles require 150 felt underlayment, min 4/12 pitch, and valley fleshing of not less than 28 Ga. galvanised •.m. or laved composition shingles. ALL "nZiortormazst .. \.46+. Liar a pima Aerrits0 ' -'rri4 11T MICA _ Sy1LDIJX, GIFT. Afl ,. L or Mact . GAL s, . clot. 1* " t?l%lcjIJ =ETA' LS t _ a uelL1Cis eta SI Te rat t I`R&p. 11.14 1 {.fPErcT1otj. '1+c& H1752 • moss!, 'TRIM! r s 24 "O. G . 1.••14-61 /12 y,/12. ?I TC.FI r k • GOND limb none -- 'A • SP SIP 9. -- __ V a - SP Se - — J • ',rat . \ NO_ IS *moo S -vwsek e 2•14 `I daG. L = 201-0" ) Co /t2 •/ ! viz prram M� 4 .vg I RS - rt2ogens 6 2e"o.G, .t C. = 14 t o ) •l2 /; 3 /'a 1'rrGW 8614- 030S 1.. • • peN axe, NPR • ,$ y Rsichrutoat 1 7 • r� •1 1 1 1 t 12 4iRAl.R 11 u' 3 f raj PAt.LO ;too e 2-4"a‘. asilWroeserca. L = to 07' [9c2 4rrc.w 14K!o $7 1 ROO FRAMING PLAN • v. sMPtaJ 73 141. M I ILL dt Momma y,4610 vt CITY OF TUKWILA APPROVED SEP 19 1994 5111P BUILDING DIVISION RECEIVED AU9 2 21994 raw s • C3) U *tern '� sot. whtg� I we • So raur too 144 �W • :e�1.11� 1614 e s ger use e 24' n. 1 It .._._. — • SAM v.41-10 gikrpte4 IL4%e PILL I61 • ' .t J "rw &abl[i14 M►/ etAle" troge.a4 ? PL.frk.s414-J4e) MIrJ. EctAO IiJeuL, '- 5/• j4t1'ac . 1 /2"tp, 15a • eat S-;uOrt s u'ro c • !b'q•o bovoL. 1'I 8 ffr tot. •'/ Gawt tleThki- girt= EAVE DETAIL ROOF CONSTRUCTION (4) • Ive Ate es1p, 400 WNW* fu"ac, *4:, 'Si nati -A GLUED 4 I• JL v�P. Elate . �--- f . d Jere. stein. a •a .. • • ftciM 1014100.112 ML) Io f..Ik &Oa. 4 lermi gut*, vie 4 1 L Istt4. 114..1 V. s • a • •4 1ata • 3 FOUND. DETAIL IV • 1' • • • • • Cedar shakes 1 x 4 spaced Manufactured Min. R-315.0 i 5/8" G.W.O. iriterlacea with IN " -30N felt o/ sheathing ;solid (• overhang) o/ roof trusses @ 24" u.c. and /or 2x nsulatiun EXTERIOR WALL CONSIRUCTIHN • • • •• • • Siding per elevations u/ 15# building paper o/ 1/2" COX plywood sheathing o/ 2 xat studs 14 16" o.c. Min. R -M•0 insulation with vapor 1,,,. Lint u/ 1/2" G.W.8. GARAGE SLAU CONSTRUCTION • • • 4" concrete slab o/ Comp. fill Slope 4" towards u.h. doors FLOOR CONSTRUCTION • • • • • • • • • • Finished floor covering u/ 3/4" T&G plywood, glued b na i I.,,t u/ 2 x floor joists o/ Min. R -19.8 insulation Min. 18" crawl space betw„on I,1t:.t.5 ,ntl :Mil kir Mil vapor barrio ov01 ..uii NSTRUCTION raf tut :-; (!it,I, roof framing plan) Vs ' •rdres. PLTWdd00-1ctc liT1 it lx10 Jbf Q It) oscuist t �. J�"'....> 1! II 11 sto*A1i4t4 . Cows, WA:.ley MEW' Pe env Puler1" *Iran ts1$ "0.9. A11.70 ArkGROft emazru' 94-1 In ex so' eat L I�T/�yI�G• ��i. 1yyIA�1 i�t��.�JyV�7 TiwiM� 1401.301- r/Ii OMFAILIE atapl LU►Jfo • • • 1.• 1. F M ./3•o 156004 4. " eects4be kkui. w/'4.•. .g 10 O•G. V 1101?) in 's afrelNc., 41 iG01 *.4l, •/ [y'••-iiLeFI1.M Va. °" •'w I • • • 4" re, Sat: vt. u /(0PKAws. I l.l. • 1 1. g= 1c1.0 rot itcl disc ME .Isn' . • .♦. -.. • -r• h•. -.• _. ♦ . - -•• • .774t• e • 'Co x beOM&. tic . FOUNDATION DETAIL 2 1/Z' cif' ea. 43t'q eT{Ja• s • Col 101214.4.• 'TRtstr Uo �6!LL a/Ye'� K 1484.1b' e v.�. se marl g4% ft• I�I.o;sJtUL, 4'a+ -1c. tL't ma lel Tog ei112 • r & rt.- V R5. J 61'40,1-14. _ i(x 6' 4,04e. ce -14D. • Pa trl by 14" ni• z FOUND. DETAIL 11 /2" • 1' M F D . pis F 't L C aP UPPER FLOOR CONSTRUCTION • Finished floor covering o/ • 3/4" MG plywood, glued & nailed u/ • 2 x floor joists • 1/2" G.W.U. >< Ait 11 Z it I v 491'4? (, t(r''O,G• Max. rise 8" min. -run 9 ", headroom writ. 61`", min. width 3e Handrails to have ends returned b" anti placed 31" -30P above tread nosing, guardrails min. 30' high with intermediate members not more than de apart. Fire block stairs between stair Stringers • top & bottom and along run between studs. Usable apace under stairs to be surfaced with min. 5/8" type X G.W.O. * Hs.jIZAILS MI1.1 I' /Z" To MA+. z' tU Ct WIL -tl nol. i mil. MST.JSIOI.1, 41-411J 0._11 •eSnAA %aetu , Y r 31) 9" O tit II ,r(IQ4srTfs. G ;- --- -.1 SLAB FLOOR CONSTRUCTION • • • • • Finished floor covering o/ 4" concrete slab 0/ 4" compacted fill n/ Min. R910.O insulation (24" a pnrimpt.t.r) Mil tabor harriur CITY OF TUKWILA APPROVED SEP 19 1994 AS)NG ED BUILDING DIVISION Mi •A• el OM OPTI YVNA AU6 2 219814 paw 011a bLbG. SEt 'AA' .r I /Vat. V¢ W Gwlgy Au0 cut:0 c .Jf VON =MP N O° 51' OS "E 154.91 MID f N fit 4o'43'W l�1 4t EMIST. DRNLwM AMO Cane GUI N o° 91' OS' a 114. W 0 VIEmm 0 EXIST. NpugE Mo• 4b46 0•i" AROtig etMoir • . ITT 15T 1 G 4ITE ants no* APPACAT NEW GRAVE. L Ints4wAy MEET ExIST. DtK4way EI.IICAUCE. talks • Pans t t ibKtt.• 41../0* 4. c• -.e' _ fl - N O° elte 37" E 249.63' 01 611.101.0 e.. - we 10' GENERAL NOTES — Ex ISTIM6 tomcat E. Cut% ctn MO At PAVED OQWEWAY Tan R. \1JCE 1 Al I. WORK MATERIALS SIIAI.I. BE IN CONFORMANCE WII'll TIIE STANDARDS AND SPECIFICATIONS OF THE CITY OF TUKWILA UTILITY DEPARTMENT AND TIIE LATEST EDITION OF 771E WSDOT /APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON 511E AT ALL TIMES DURING CONSTRUCTION 2 rim IIOIIRS OF WORK IN THE STREET RIGHT -OF -WAY SHALL BE LIMITED 10 8-30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY TIIE DEPARTMENT OF PUBLIC WORKS AT 433-0179. All. STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY TIIE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE THE POLICE DEPARTMENT. FIRE DEPARTMENT. AND 911 SI IALI. BE NOTIFIED 24 HOURS IN ADVANCE 3 ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND 1'1' SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48 -HOUR LOCATORS. 1-R00- 424-55S5. 4 A PRECONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF 3 (THREE) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. PRIOR TO SCI IEDIl1.ING TIIE PRECONSTRUCTION CONFERENCE A PERMIT INFORMATION SHEET MUST BE SUPPLIED TO THE UTILITY ENGINEER'S OFFICE TWENTY - FOUR HOUR NOTICE WII.I. BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION S IF SI IALI. BE TIIE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 6 INSTALLATION OF CORPORATE STOPS. WATER SERVICES. LINES AND ME'T'ERS IN TIIE PUBLIC RIGHT-OF-WAY WILL BE DONE BY TIIE LOCAL WATER Al TIMMY AND SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS. CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE WATER AUTHORITY. 7. MIME A WATER MAIN CROSSES A SANITARY SEWER, A MINIMUM VERTICAL SEPARATION OF 18.1NCIIES SHALL BE MAINTAINED MINIMUM HORIZONTAL SEPARATION OF 10 FEET SIIALL BE MAINTAINED BETWEEN WATER AND SANITARY SEWER FACILITIES. 1 WIIERE A WATER MAIN CROSSES A STORM DRAIN LINE, A MINIMUM VERTICAL SEPARATION OF 12- INCITES SIIALL BE MAINTAINED. MINIMUM HORIZONTAL SEPARATION OF 7.5 FL•E'F SIIALL BE MAINTAINED BETWEEN WATER AND STORM DRAIN FACILITIES 9 WI HIRE A STORM DRAIN LINE CROSSES A SANITARY SEWER. A MINIMUM VERTICAI. SEPARATION OF 12- INCITES SIIALL BE MAINTAINED. MINIMUM HORIZONTAL SEPARATION OF S FEET SHALL BE MAINTAINED BETWEEN STORM DRAIN AND SANITARY SEWER FACII.II TES •...cusat LOSS wt tt /N SITE PLAN 11) ( :AI.I.UU•r ITEM LEGEND: IQ. CATCH BASIN TYPE IP. RIM ELEVATION 363.0, INVERT ELEVATION 4- INCH PVC 361.5. INSTALI. OUTLET CONTROI. AS SIIOWN IN 11ETAII. I CENTER OF CATCH BASIN IS 130 FT. NORTH OF TIIE SOU'1'll PAOI'I:RTY LINE AND 13.5 FEET WEST OF THE EAST PROPERTY LINE. 0 HDPE CATCH BASIN, RIM ELEVATION 363.00. INVERT ELEVATION 4 -INCH PVC = 361.4. CENTER OF CATCH BASIN IS 130 FEET NORTH OF SOUTH PROPERTY LINE AND 23 WEST OF EAST PROPERTY LINE. Q 30 FEET OF CHAMBERED LEACH FIELD SYSTEM MANUFACTURED BY INFILTRATOR SYSTEMS. INC., BASE ELEVATION • 360.4. NORTH 2ND OF LEACH CHAMBER, CENTERLINE, IS 126 FEET NORTH OF SOU'1'11 PROPERTY LINE AND 23 FEET WEST OF EAST PROPERTY I.INI. Q CATCH BASIN TYPE IP, RIM ELEVATION 354.0, INVERT ELEVATIONS OF 4-INCH OUTLET PIPES = 3S2.S. INSTALL OUTLET CONTRCL AS 51IOWN IN DETAIL 1. CENTER OF CATCH BASIN IS 48 FEET SOUTH OF NORTI1 PROPERTY LINE AND 13 FEET WEST OF EAST PROPERTY LINEE. 3 -1 -INCH WATER METERS AND SERVICES WITIIIN THE RIGI11' -OF -WAY TO BE INSTALLED BY TIIE LOCAL WATER AUTHORITY. WATER SERVICE LINES FROM THE METERS TO THE HOUSE PARCEI.S TO BE INSTALL BY THE CONTRACTOR. Q CONNECT 3. 1 1/2-INCH DIAMETER SCHEDULE 80 PVC FORCEMAINS TO EXISTING SIDE SEWER STUB AS SIIOWN IN DETAIL 3. 0 48 FEET OF CHAMBERED LEACH FIELD SYSTEM MANUFACI IIRED BY INFILTRATOR SYSTEMS INC.. MAINTAIN A MINIMUM COVER OF 18• INCHES OVER CHAMBERED LF..ACII FIELD SYSTEM. TYPICAL FOR PARCELS B. C, AND D. SEE DETAIL 2 Q 24 FEET OF CHAMBERED LEACH FIELD SYSTEM MANUFACI URED BY INFILTRATOR SYSTEMS, INC., BASE ELEVATION =351.2 SITE DETAIL 2 Q 3.1 1/2 -INCH DIAMETER SCHEDULE 80 PVC SEWER FORCEMAINS. MAINTAIN 2- INCITES CLEARANCE BETWEEN PIPES AND BED IN SAND 4- INCHES AROUND. MAINTAIN A MINIMUM OF I8- INCHES OF COVER OVER TIIE FORCEMAINS. MAINTAIN 2FT. CLEARANCE FROM EASEMENT LINE. 0 GRAVEL ACCESS ROAD 12 FT WIDE BY 240 FT LONG, ALONG EAST PROPERTY LINE WITH A 20 FT WIDE BY 6S FT LONO BRANCII FOR ACCESS TO PARCELS B AND C. BRANCH HAS TWO 40.5 RADIUS AT INTERSECTION WITH NORTH -SOUTH ROAD SEGMENT. SEE DETAIL 4. 0 REMOVE EXISTING FENCE * •; - 4 71 1 VICINITY MAP ABBREVIATIONS: CW CONCRETE SIDEWALK EXIST. EXS'FINO WM. WATER METER SD STORM DRAIN ELEV. ELEVATION EA. EACII CB CATCH BASIN 1V/ WITH MIN. MINIMUM U.O. UNDERGROUND SS SANITARY SEWER S.Y. SQUARE YARD IT. FEET TC RAY AC IE. MII DWG O.C. MAX. CI.R. CONC. S.F. 0.11. W.1• TOl' 05' CURS RIGHT -OF -WAY LINE: ASPHALT CEMENT PAVEMENT INVERT ELEVATION MANHOLE DRAWING ON CENTER MAXIMUM CLEAR C UNCRFTF. SQUARE FOOT OVERHEAD I -INCH WATER SERVICE DRAWING INDEX Cl SITE PLAN C2 DETAILS AND PUMP STATION NOTES LEGEND RIGHT -OF -WAY LINE EASEMENT LINE EXISTING CONTOURS SLOPE ARROW -. PROPERTY LINE 354 OWNER: VANDENBERG PROJECT ADDRFSS: SUBDIVISION ADJACENT TO 4646 SO. 160TH. S'1'REK I awcr AUS 2 21994 mar G.,, , CITY OF TUKWIIA APPROVED SEP 19 1994 AS NOTED BUILDING DIVISION iteriataiee 1 ! tt. • . VANDENBERG SUBDIVISON SITE PLAN 110. RtvletoN HY APPR. OATt Ots1°MtO DRAWN 31.1 1 CNECKtD OATr �•� -44 tCALI 18". zQ /— PILt NO _ 11 1Itl.e ROOM_►AOt__ APPROVIO bgt.N Or POI lit t1Sty 1IHttt _1.. .O /l.