Loading...
HomeMy WebLinkAboutPermit B94-0308 - COSTCO - STORAGE RACKSI Chy0 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Tirtm� .� (206) 431 -3670 Permit No: Type: Category: Address: Location: Parcel #: Zoning: Contractor License RACK STORAGE PERMIT B94 -0308 B -RACK 1161 ANDOVER PK W 352304 -9097 No.. TENANT COSTCO 1159 ANDOVER PK W, TUKWILA, WA 98188 OWNER WAREHOUSE PROPERTIES ASSOC 3201 FAIRVIEW AVE E, SEATTLE WA 98102 CONTACT JOHN WARNICK 1 159 ANDOVER PK W, . TUKWILA, WA 98188 :.. ********************************************* *k*** * * * * * * * ** * * * * *•k * * * * * * * *** Permit Description: Status: ISSUED Issued: 08/30/1994 Expires: 02/26/1995 Suite: Phone: 206 575 -0701 INSTALL RACK STORAGE Rack Storage Dimensions,- Linear. Feet` x Height = Totals 606 10:0 6,060 .0 .0 .0 .0 .0 UBC Edition: 1991 Valuation: 13;.7.70.00 Total Permit Fee: 060 256.9 ****^! t*)' t*******************************,********** * * ** * * * * * * * * *. * *. * * * *.k.�i * * *** Perm Center Autho Ized Signature Date I hereby certify that I have read and examined this permit and know the same to be:true and correct. All provisions of law and ordinances . governing this work will be complied with, whether specified herein or not. The granting: of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe formance of work. I any authorized to sign for and obtain this ildingt rmit. ti Signature: Date: F 3 Jq/ Print Name: Z-0 VVAfnj: Title: 1roJs? f(\tvy'- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWIL' Department of Community Development - Permit Center " 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER K -0303 PRO ECT NAME .OSTCD CONTACTED SITE ADDRESS 1159 Ado U E. PK 1AL SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMENT DATE IN DATE APPROVED BUILDING - S-ze ` et g, CONSULTANT: initial review 8 -(3-41 ____IROUTEDL %1 FIRE �r ROUTED r S (/ FIRE PROTECTION: �� Sprinklers Detectors N/A FIRE DEPT. LETTER DATED: s-..IL, s/ INSPECTOR. Oc) UIREMEN Date Sent - )MMENI Date Approved - O PLANNING INIT f/1 #Jr /b INIT: V CA- ZONING: REFERENCE FILE NOS.: BAR/LAND USE CONDITIONS? O PUBLIC WORKS 0 OTHER BUILDING - final review • • N/4 INIT?1-1-/° MINIMUM SETBACKS: N- S- UTILITY PERMITS REQUIRED? tj Yes (y)/No PUBLIC WORKS LETTER DATED: E- w- BUILDING OFFICIAL INIT. 11)14141 INIT�%�Lt TYPE OF CONSTRUCTION: PVCV$ CERT. OF OCCUPANCY? OYes (o No UBC EDITION (year): INIT: REVIEW COMPLETED AMOUNT OWING: C/ 0 CONTACTED DATE NOTIFIED • BY: (init.) 2nd NOTIFICATION BY: (init .) 3RD NOTIFICATION BY: init. 01/08183 CO3TO BUSINESS DELIVERY 206575$080 CITY OF TUKWiLA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 P.02 BUtLDtNt' PERM1T APPLICATION PLAN CHECK 5Ciq 030 NUMBER APPLICATION ROUST BE FILLED OUT COMPLE I EL Y Sir At7Dt7/Ff�ESf5 ) SUIT' 1E # 11 Jr-t f \' wn, pI..a titles i Bvi I PROJECT NAME/TENANT C S+O( c TYPE or WORK: 625-Ito L$b 1 New Buil•mg ■ Addition Rack Storage Q R f ❑ R d DESCRIBE WORK TO BE DONE: AMc W1T s 3DiNG ERk4 X .EEr: ;: "' 1.. RCPT' . :'i^ ib E �.M c VALUE OF CONSTRUCTION - 13,710 ASSESSOR ACCOUNT# Sat t - g01$_O - Tenant Improvernen (cornmercta) Demolition (building) ergo er io e1(residerrtial) Q Other: Fr�ec4 sine i {SAC ks BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: NI; it, o Ct SJ Frenawl Pr"J Fcxb� Ar`- P- udk/i� �...d oRw- l�.u�:,r1,r WILL THERE BE A CHANGE iN USE? ►:4 No ■ Yes if Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: Rai ?- l Tenant Space: aLG,$6z Area of Construction: .a SS�- WiLL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 0 No 0 Yes IF YES, EXPLAIN: LFIRE PROTECTION FEATURES: , Sprinkters .Automatic Fire Alarm System CONTRACTOR ADDRESS 3at�:tyv PHONE 3 DI - %oi.S tZIP WA. ST. CONTRACTOR'S LICENSE # ARCHITECT ADDRESS - PHONE EXP. DATE PHONE ZIP E - EBY-:Cr1tiR[F,x` BUILDING OWNER SIGNATURE OR AUTHORIZED AGENT CONTACT PERSON DATE PHONE 329 -7075 APPLICATION SUBMITTAL in order to ensure that your application is accepted for plan review, please rnake sure tone out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittai requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCT t EtvEt7 Valuation for new construction and additions are calculated by the Department of Community Devetopmaitp r it riyalaation submittal. Contact the Perrnit Coordinator at 431.9670 prior to submitting application. in all Case. a a unt should be entered by the applicant. This figure will be reviewed and Is 99 .... ' - •- •- ..- ...........Hk .r tyrant fan CRhAttlias. DA' 6..4 ►� „et t e e d S --( 3 -1 PERMIT CENTER Pi �� S .--.. —15 k *k * *iF * * *k * * *k* t•h*/ *kkh•k*kk•hk•k:****** *** ** *A*hk* ** *A** i * *•k ***A••k* CITY OF TUKWILA, WA TRAN:;M] :T * ***k ****A**k **** **** kk************** *•k*** **•k•A•***k *****kk*k•k*k* TRANSMIT Number: 94001101 Amount: 256.95 08/23/94 16 :46 Permit No: B94- -0308 Type: B -RACK RACK STORAGE PERMIT Parcel No: 352304 -9097 08/24/94 Site Address: 1161 ANDOVER PK W Payment Method: CHECK Notation: JOHN WARNICK ]:nit: SAO *k A* A**** kh k***** A•*•* k** k* k***• k*• kk* * * *** *k*** **k **kkA*k *k * * ** * *•k* Account Code 000/3222.100 000/345.830 000/386.904 Description BUILDING •- NONRES F'LAN CHECK - NONRES STATE BUILDING SURCHARGE Total (This Payment): Total Fees: Total All Payments: Balance: 256.95 256.95 .00 Paid 153.00 99.45 4.50 256.95 GENERA GENERA GENERA TOTAL CHECK CHANGE 4968A000 153.00 99.45 4.50 256.95 256.95 0.00 15 :49 w4 1. i INSPECTIONi RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 03 ocZ PERMIT NO. (206) 431 -3670 -project. 1�fiCe �o��c r� Type o n(1 s n: `�'�� Yla� Address: , Date Called: - Sp=• al Instructions: �4. l'' G Date Wad' z 9 p `7 ^- `T am, m Requester 0 14 WCAA. 11 CC IC Phone rzo6) 5'7C 07 0 Approved pet applicable codes. COMMENTS: ' ❑ Corrections required prior to approval. /7.a F? -di-2-'N) ❑ x.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. IS.oxs�r:�.ZItteA City of Tukwila Fire Department John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name LM- t' %7/' D Address 1 T ./'..J, /permit No. Thomas P. Keefe, Fire Chief ?yiy... 6308 Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: t% Fire Alarm: Hood & Duct: _AL_ Halon: /_ Monitor: Aip 7 ‘ 6 t„, )4 to r Pre -Fire: V Permits: 1 Date Authorized Signature FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575,4439 CITY OF TUKWILA Address: 1161 ANDOVER PK W Permit No: B94 -0308 Suite: Tenant: COSTCO Status: ISSUED Type: B -RACK Applied: 08/23/1994 Parcel #: 352304 -9097 Issued: 08/30/1994 *•k *•k* k*k* * * ** k * * * *****•k*•k * *•k* k•* * * * * *** k **•*•k** *** k*•k *•k****** * *** k** * **•k*•k* k k Permit Conditions: �.,.., 1. No changes will be made....to:,;t+hep`.1aris";1.e: approved by the Architect and the TukWatBu11ding `Dilv4sioh',, 2. All permits, inspacb;l ii recor,,ds, and, appr ovd'd :plans shall be maintained avaui 1ab.le at hef Jo sii a prior,` to th'e start of any construct .Opr. Th:ese� d'o,curpent -s% arse to beimainta1ned available until f,. �rii31'�.,inspe °ctian approval granted: 3. All aonst,l1 uefion t`o be done ,in °''corifdrna0ce withyapprov ^ plans and` .regytirements ,of`'the. Uniform Bui1`ding Cnd9.�1� Edition {a's amended by''' the Washji,r {'ton State '�Bui lding,'Coder$ 4. V a l i d i1t"y`; o f Per i' i t. `The i :s r u i n sgsdf, p p "f;4,. rr �.'.d ce oi=' a permit or. ��` r�cval ,►� p1ans;,,�pe;cificatins and.,aomputati;oris shall not',be'ciin''' strue,dpto4,be a permit f;0r, or'r,,an ,approval of, any violation of any of� •tie provisions of this code. or of any other, ord�nance of the Jurisdicttorpf No permit presuming'.,to give author'ity•-or violate ror cance`1 ", the >provisions of this cide sha'fl be valid. 1 '1 CITY OF TUKWILA RACK STORAGE DIMENSIONS LINEAR FEET X HEIGHT = TOTAL 60G X io = (0a X X X X X NONNI MOWN GRAND TOTAL = 6, o 1_ X je. / "7-‘: ) •.0 '0 c‘ 0,-. ....... •■■•• ■•••••• ■•••••• gOa. ••••• 1 .-D Ao, ! 6 4. cavz ■ . -'.." .--'"` "7 '.i--.. • ITT; . : ,-....., i.....: ....1 ....... .it 4„ • . CL 21 i i ...'' i • O.- 4 . t • 0 . ....:-..1.... i ■ _ 1., 2 .)- • 1 :4 strn" ' 1 ! 17 c.... —:!-Ib- Mir: ,,. 5 Li' ;L. .i 8 '' ' 2 ' u. : Li ..... , t '.1 1,..._. ,_ 0 . ; 4, .........„.... F • 1 ; ; . —4 Li-4 tL %) [13 . ,0 'e:CfXr. r4' • 'zo QJ t\i\511 .-r":76.1::". 7. .4. • .11 1.. filb-coe •eo. *.oHJAbo oolsdoiniNd 19 6. OS 06-C 1-eny 11•111•••• 0 0. 0 0 u- tEl < (1) CC will LLJ cl) > 2 wzw CY) I- EL 0 t- o u) 0 u_ u, crN_ c1C co 111 > LU —I m EE 411•11•111•••■•■1•14111•1 411•1111•■ zr) 1 z 1.- 0) • in 0 1 Y 0 1 1 J U 0 C.) Lc• rNi • W • w M• � w zw J �m 'Z V M LR; LEVEL RACKS qU 0 0 CNI U LTJ M� w G5 • Q z W I C-9E' i- n. • ff caz Cr eaS w• rrn C) Cr, U %} 0) GM U .G -o J (G • Velma maw se z 0 cc LL z 0 -J -J w U x .. 0 .- •O a N • 0 0 .- 0 . r o . r.. 0 0 U O M 1 M. to 0 x (n N .. 0 0. 0 . N . M M N IA I+ N 0 M -s 111 Y1 CO a O N O 0 0 O O O O 0 •• •- 4 M O v tn ,ail d d O M O 2 O ir.2 0 P O . c M .p 2 to O O O to 51 0 U � N .- •• N M • M M N N J 0 0 0 0 0 0 0 0 .- Fes- O 0 0 0 0 0 0 0 K I M M M M M .t .t /11 0. U1 en /+ •'00 O a O ti O N O O. .'" a O - .~- O O O O O O O O r CO N N O M O vv '0 r W u. U. U W i C c z 0 cc LL z 0 -J -J w U x .. _ M O t. O N .- o •-• N O M M 1 M. to � `0 x (n N .. 0 OW Ln .100. 0 0 O• 0 O. N . • .t .• CO .• N N I+ N 0 O 0 O 0 O OM O O O 0 O O O 0 O 0 p0 p M M M co O O N O 0 N 0 0 N 0 to N 0 to N 0 tit h N 0 In N 0 111 N 0 U � N T 4 N N M tel J J to to 10 1- IN,. T2937 Inn F. CO O 1- .- Fes- 10 h .- 1�.• .0 F 0 F N -► a U N N N C en 0 = Z m 09'S 2 _l 0 cn0� u) w < 0 zz 0 - <o= 5 ta 0.14. g N 0 rob ft C EE0 O (1) U 0 U CC < a- cc 11.1 n JLU L w 0 � W f— z VJ Z V 0 M0 0 z • • 0 fly - aOZ �OO W (3(0} uNi' S W 1 In y Vi N`' --_-a '„ aa00 IT 1\ [1 // 11 CU 0.0 0.1) N NU yc E' t0 0) 03 in N O x O O 0 O r° r r 0 r V O a O X L N 0 r 0 e-• M NI r 03 •-• VI In •+ yIM `0 .^t tD vAi 0,0 ,,pr ' ar0 0 00. op O N I M O ? 0 VOi O IOA 0 h 0 03 0 0 Nr a 0 r N.a N.4, r r 0 In N 0 o Nf 0 0 M 0 o M 0 In N 0 � N 03 O 0 CO 0 0 0 0 0 0 0 0 ri 0 0 M 0 0 .t 0 0 • = NI N1 VI 4 to 0 0 P 0 0 0 0 yy(4 0 0 0. 0. 0 ^ 0 0. 0 0 r r- 0 H .�- W 0r U N 1. N l M LL M u Qs, 0 .0 a 0 x M 0 ti O N • r• 2 r r N O N1 03 h N1 M V1 rM m •0 0. 0 N. 0 0. N. r 0 X N N V1 •0 O. 0. N .t 03 N 0 0 0 0 r r r N N h O 020 O CO 0 03 O W 0 a�0 O 0o0 U 0 O O r 0 0 0 0 0 0 0 0 0 O O O r r r r r O O 0 0 0 0 0 0 O CO 0 0 0 VI V1 V1 V1 IA V1 1∎1 N N 14 N NN N N 4 P o0 O G N N en in 4 -t In V1 •O 0O 2 (4, a%o '`3 .`n% 'n�i .ao 00 . ^N 10 H a tm O z a to CL N L tions drawin a ai 1 _1 Min 3/8" Anchor u d "" O r• 3 O £ , "0 C.3 c 0 N co L 0 4�.. w '"" 2� 5o wC m E. Qa <o= N I g g C3 N P L V O la Ch 0 L I •C T ry�N L 10 O N t: L O VI N ,a. IN ii d 0 C N y C 3 in • > L. (0 .y 01 > h• Ge a .V+ .G�t CV1J W O > L N .c CC 4. e- e- ~ 3 01 4Li L b 03 '^ ^ b (1 7 CO O co 1- O_ N a,tOmO N.0 •? C -1020 0 O �g a7 Uv�•p I+M �j fO �L t.. .43 L 0 x�tl� O V1 v'D m aN! ; L 2 y 0 sli x U ^^ EV 4, x 7 0 • R •p i, N IEn 1 LL 0 C � ~ ED V. RO 41 .iia "11 >g. 1.. 4, •C 4',N C O Ul.O c -s O.EEC @ 0 c L O.r ry. rn m u .0 v v .n R a o H :Oit E 0 w C 0 c y a S O ' O' L S A msN 1+ !D u N= '0 , Om Lr Wy CO la j0 05.p5 U C Q s y . L e VI) C (/� '2 To La p1 M W J O ~ ,@,~ ,� C ... M N 1.• C Vl .0 j 4,a eL' 'V) L t! y QL C yu�. y� ,C.,'� Qe V V O CO y ..oi VWyV111 �; ]t MI 411 L. '.a, ^U .dam 4 N� O ^N C .'O�= 4*""111111.11■11110, N1 J V1 simmdorir BEAM - COLUMN CONN STANDARD DETAILS M Q) A ...("1 o th z 0 UJa 0 • 0 O Q. r • p I,I<VZu.c° Lit ? •0 y (y. PriceCostco USP Racks Location: 1159 Andover Park West Tukwila, WA (Zone 3) E17;711 S - .D -gip Prepared For: PriceCostco Incorporated Kirkland, WA Prepared By: Peter S. Higgins And Associates Consulting Structural Engineers 1225 -F North Pacific Glendale, CA 91202 (818) 549 -0072 Peter S. Higgins, S.E. Job Number 1427 August 5, 1994 CITRECEIVED EIJKWILA AUG 2 3 1994 pERMIT CENTER This Document and the design it c and Associates. It i= ovided be reproduced in y fa ion N. ice If this cal •u ation is contain al s eets of the next •a •-(s) Section 1 •11 ink of a on calculati• s ocum rest all tains is co an instrument thout written pe right by Peter S. Higgins of service, and shall not mission. Building De bmitted for building "1culation= •• ted in shall • ed b s s .ria_ c 1 b or wi ned acr ar h t ss th ompan appro e artments ermit approval, it shall the table of contents on 1 dra listed in se • s •nd si tures in ob Number Refere . The. W// REPRODUCTION • OP/ES ARE INVALID Cld,/�'_ r n\+,\4 wit tZ XER S. HIGGINS AND ASSOCIJC S CONSULTING STRUCTURAL ENGINEERS Project: PriceCostco August 15, 1994 Job No. 1427 Sheet ii Table of Contents 1 Reference Data 1 1.1 Documents 1 1.1.1 Drawings 1 1.1.1.1 By Peter S. Higgins and Associates 1 1.1.1.2 By Others 1 1.2 Loads 1 1.2.1 Vertical (Dead plus Live) 1 1.2.2 Seismic 1 1.2.2.1 General (1991 UBC Standard 27 -11) 1 1.2.2.2 Short Formulation 2 2 2 Level Racks 2 2.1 Components and Geometry 2 2.2 Check Beams 2 2.3 Check Posts (Dead plus Live Loads) 2 2.3.1 Load to Post 2 2.3.2 Post Properties (net section) 3 2.4 Longitudinal Seismic 3 2.4.1 Base Shear 3 2.4.2 Design Forces 3 2.4.3 Post - Combined Stresses 3 2.4.4 Beam Connections 4 2.4.4.1 Design Forces 4 2.4.4.2 Connection Capacity 4 2.5 Transverse Seismic 4 2.5.1 Base Shear 4 2.5.2 Design Forces 4 2.5.2.1 Stability 4 2.5.2.2 Brace 4 2.6 Slab on Grade 4 VILER S. HIGGINS AND ASSOCIA' ya CONSULTING STRUCTURAL ENGINEERS Project: PriceCostco Job No. 1427 August 15, 1994 Sheet 1 1 Reference Data This calculation reviews the installation of storage racks for structural adequacy. The sealing of drawings is for the struc- tural review of the storage racks only. Other information is not reviewed, nor approved. Note: the single level rack is exempt from building permit (although it easily satisfies seismic crite- ria). 1.1 Documents 1.1.1 Drawings 1.1.1.1 By Peter S. Higgins and Associates CW -1, US -1 1.1.1.2 By Others Mulvanney Lee Project Sheet A -1 Rev. (rack arrangement) - TO COME (Temporary floor plan 83x11 approved) 1.2 Loads 1.2.1 Vertical (Dead plus Live) Loads per level = 5.0 kips Design beams for 25% impact of one load (conservatively take 10% of entire load on full span) 1.2.2 Seismic Zone 3 installations are designed to Zone 4 criteria. 1.2.2.1 General (1991 UBC Standard 27 -11) Where: V _ ZIC 1✓ R !✓ Thus: 1/< 0.75W R«T2/3 within the range: 0.031/5.V5__0.1831-/ Z =0.4 I =1.00 Rw =8 Longitudinal 6 Transverse C- I. 25S52.75 T S <1.5 (unless lower value per- mitted by soils report) W =Total Load (Dead Load of rack is usually negligible) T may be determined by any rational method, or the default C /Rw of 0.50 may be used. „..ER S. HIGGINS AND ASSOCIA CONSULTING STRUCTURAL ENGINEERS Project: PriceCostco August 15, 1994 Job No. 1427 Sheet 2 1.2.2.2 Short Formulation If racks are interconnected such that 4 posts in each direction resist lateral load, then (using code defaults for C /Rw: V= 0.183( l DL+ 2 1 0.106✓ i (since DL « LL) This condition is usually satisfied by interconnecting back to back rows of rack, or by tieing single rows across the aisles. 2 2 Level Racks 2.1 Components and Geometry w w =10S" a =60" b =60" Beam Type T5125 D r H =120" D =34" 1y =50" ld =56" Upright Type F18 2.2 Check Beams OK per previous checks. 2.3 Check Posts (Dead plus Live Loads) 2.3.1 Load to Post v P <01 of levels)(L) 2 =5.0 kips .:ER S. HIGGINS AND ASSOCIA CONSULTING STRUCTURAL ENGINEERS Project: PriceCostco August 15, 1994 M Job No. 1427 Sheet 3 2.3.2 Poet Properties (net section) 1 $, F18 1, 3 t =0.095 in 1y /ry =76 a/rx=50 X - X As =0.48 in2 Sx =0.47 in3 Fa =19.8 ksi rX =1.20 in Sy =0.27 in3 Pa =9.5k , ry =0.66 in M— ca =14.1 k 2.4 Longitudinal Seismic 2.4.1 Base Shear Determine Period - Rayleigh Method - This equation has been reviewed and approved by ICBO for use with steel storage racks. 3 T >_ 300 itt/L(2n2+2n+ 1) 2 Substituting yields: T >1.9 sec Thus: V <0.060W 2.4.2 Design Forces P <5.0k V <0.30k M <Va /2= (0.30) (60) /2 =9.0 "k 2.4.3 Post - Combined Stresses Units: kips, inches, seconds Where: W = Load per level L = Spacing between levels I = Moment of inertia of post n = Number of levels P M Pa Ma =1.17 <1.33 O.K. ICER S. HIGGINS AND ASSOCIA CONSULTING STRUCTURAL ENGINEERS Project: PriceCostco Job No. 1427 Sheet 4 August 15, 1994 2.4.4 Beam Connections 2.4.4.1 Design Forces Mconn5.0.9"k 2.4.4.2 Connection Capacity OK per previous checks. 2.5 Transverse Seismic 2.5.1 Base Shear Use Code Default Values for CS V=0.183W=1.83k 2.5.2 Design Forces 0 `414 h' r EQ 2.5.2.1 Stability Vh' Peg D h'=90 inches Peci=4.8 kips Note: Bracing shown is schematic - see this section, subsection .2 for actual geometry. eq_ + P L Stable-No Uplift. Anchors provide added Factor of Safety. 2.5.2.2 Brace OK per previous checks. 2.6 Slab on Grade A:2ER S. HIGGINS AND ASSOC/A CONSULTING STRUCTURAL ENGINEERS Project: PriceCostco August 15, 1994 Job No. 1427 Sheet 5 Treat slab as equivalent unreinforced square footing 8 B= 22(j) Q a =26.8 in —1 (B—b—t) Lc 12 2 =0.64 feet Ma=(Qaa )(12) 2 =2.45 in kip/ft Where: P = 5.0 kips b = 6.5 in. (average) t = 5 in. f'c = 2,000 psi Qa = 1.0 ksf (12)(t2) S - 6 =50 in3/ft a = Mc Sc =0.049 ksi SWF: Callow 1.7 =0.085 ksi O.K. August 29, 1994 City of Tukwila Department of Community Development 6300 Southcenter Blvd. Tukwila, WA 98188 To whom it may concern, RECEIVED ALS 2 9 '6994 COMMUNITY DEVELOPMENT The purpose of this letter is to inform you that no contractor(s) are required for the installation of our rack storage system (permit number B94- 0308). PriceCostco has always installed its own racking. If you have any questions please call me at (206) 575 -0701. Sincerely, John Warnick Warehouse Manager 1159 ANDOVER PARK WEST, BLDG. C • TUKWILA, WA 98188 • (206) 575-0701 • FAX (206) 575.0708 City bf Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #994--0308 (510) Re: Costco - 1159 Andover Park West Dear Sir: John W. Rants, Mayor August 26, 1994 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.505A) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, City (uf Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4,1) if the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3303(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 12.106(c)) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 3. Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require installation of sprinklers thereunder. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 4.1.3.2.1) All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or. modification. New sprinkler systems and all modifications to sprinkler systems involving more than Cica y Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 3 John W. Rants, Mayor 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1646) 4. In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) Maintain minimum 6" longitudinal flue space between back to back racks. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd s