Loading...
HomeMy WebLinkAboutPermit B94-0369 - TURCHINAIK RESIDENCE - GARAGECity of 71zkwili (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: B94 -0369 Type: B -BUILD Category: ASFR Address: 12811 35 AV S Location: Parcel #: 735960 -0270 Zoning: R1.72 Type Const: V -N Gas/Elec: Wetlands: Water: 125 Contractor License No.: TENANT OWNER CONTACT BUILDING PERMIT Status: ISSUED Issued: 04/24/1995 Expires: 10/21/1995 Suite: %Type of Occupancy: PRIVATE GARAGE Slopes: Y Sewer: VAL VUE TURCHINAIK ROMAN 12811 35TH AVE SO, SEATTLE WA 98168 TURCHINAIK ROMAN 12811 35TH AVE SO, SEATTLE WA 98168 ROMAN TURCHINAIK 12811 35 AV S, TUKWILA, WA 98168 Phone: 206 241 -1891 ******************************************** * * * ** * * * * * * * * * ** * * ** * * * *** * * * ** Permit Description: REMODEL EXISTING CARPORT TO GARAGE. Units: 001 Buildings: 001 Fire Protection: DETECTORS UBC Edition: 1991 Front: Left: SETBACKS .0 Back: .0 .0 Right: .0 Valuation: 1,200.00 Total Permit Fee: 81.35 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center thorized Slgnatu e Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain thi lding permit. Signature: Print Name: — Date: --407'i` 1U &.CtA11J1AK. Tit 1e: QwAi k This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. All PERMITS ISSUED FOR NEW CONSTRUCTION, REMODELING, OR DEMOLITION PROJECTS REQUIRE CONSTRUCTION, DEMOLITION AND LANDCLEARING WASTE MATERIAL FROM THESE PROJECTS TO BE RECYCLED AT A KING COUNTY LICENSED OR APPROVED FACILITY, OR TAKEN TO REGIONAL DISPOSAL FACILITIES. isAiktkosp CITY OF TUKWILA Address: 128/1 35 AV S Permit ,No: B94-0369 Suite: Tenant: TURCHINAIV ROMAN Status: ISSUED' Type: B-BUILD . Applied: .10/19/1994 Parcel #: 735960-0270 Issued: 04/24/1995 **********************4 *4***4***4 ****k**************4****4***************** Permit Conditions: t. No changes will be macle::;t.0.4:0P,A4a"*.-61*Ssapproved by the the Tukwila BuildinggDAyTS1O4i: -'-'•-•-•:.:.....:,..%:',',-,.:.. 2. Electrical permi„tis:14-fl be,!; obta i nett throUgW:tfie';;'Wash i ng to n State D i v i s i ory*0::b91'.,.: 4i1,04 Ii) *Is t tfi:es an d.!y a ,11 e'140ri cal work W i 1 1 b eA1 rt,4 e ot e'd by; that t 'a.g 61'109, 4248-66 4) . 3. All permit, ,,:l'fispe,0On,. ice co r d0 and appr 6V e,;i1E:='01ans 4601 be a va i l a b l e 4 ; : 4 t ! ' the Job ' ' , , , i i t e prior to 'eri,-. s tart -' ofcp,. nycoh,t.W.,,„ s true t i oil.:17' TOes 0document a ie Ato be ma i n ta,1 n e dT terliravaqt, a b 1 e u 9 4 1 ' f trial,. i n s p e c t i o n apPr"0.V 6)... is gran ted . 4. All cotAs.t rue t ion' to''be dorie:2(ip conf Orman ce with,:apP'rt,(*ed • , p 1 ansfait'd requirement , 0,..e.'''t the Un i f °rim Bit i 1 di ng Code (199'1 Ed i t 1.67,0 is,'Yamensfed. .ALL CODE ..REOUIREMENTS NOT NOTED' ON'''' - PLAN.VWILL-43E SUBJECT -fib FIELAANSPECT ION . 5. It Stial 1, be j the duty of the—iyermit .40,1 leant to cause tl)e' • ‘4.,' -p ,,', work-..'to rema i no a cc estq:;`1 le, a nd' axp °sell .q'fiir':An p e c t ion'.;,pui.s... tvo, pos;eg Neither t,he_bu ttd i 1.1,9 iotfA.0.1,,at1 nOr,„..thle Jur i sd lot ion" . sheMti be 1 lab he ,,,'.f- or. expense fel!) t a t 1,e'd,: 1,9'./ t h e,,fr e mo v a 1 or ilefi la ce 1.4 b'f',.any '1.,mat er..141 iCeiu gt;le d to') lOw:i:nsrpect i 0n . 6. Va I VIII tyeiof' POI') ft. ,„.11.)ei:i yo'llee \ of, Ijia .-permit or a ppro v altif p 1 ki•Sk, . gp e,cij f ilea t 4*Ciri'S ,i' 944 cdni`pls,t at,tons,,s,b al 1 not he ci-n- st,Ue to,b e e p errat.'"fori;f6 r thl \a avr:oval4bf,, any v i 01a, i o''', .t, of AD •y, of itk i p r o v i s i on- of the 'bill1iiiiigiedle-`,9 r o f ) nA,,,,,,,t, 0 t h e\ ztl, ‘,,r di p de* Pi of the ,j ur i sd i ot iloii,:`7-cNO. per m i t:,) pr e irum tt‘ il t tv)t g 4t .g, give authdroty- to violate or cancel ..(014. 0 0 p., v.,l„.t.icb ns.:bf frof code 1 14e vall,d . ,,. .4 . / , , ..„ 0 'L4v t 0, • . 0 -, • 4 It. • 4 •• r ‘' tr ■'5 V.,: h': ,: '7;' '4. ' . t,,, * e : .o t.,, '.• ':;.,, , A '++ f 1k' rza,"2.)?.• .c.1- • V ',. • . ,,, 0 • i ■.-;,1i.,,,,,,e' V4, .,.' Nh4:" ,,,,,....eq:A,6% ., ,,,, t .-'.;•'',....`' :,' "'''‘:,,k +9:1 .. CITY OF TUKWII( L »'. Department of Community Development -- Permit Center` 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER I1• -03(09 PROJECT NAME RC1W K t gDmo-d SITE ADDRESS SUITE NO. INSTRUCTIONS TO STAFF Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. O Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. EPARTME ATE IN BUILDING - initial review IkFIRE O PLANNING p -11_ qL DATE >. PPROVED: I O/2 4 R. _JROUTED) i PUBLIC WORKS 0 OTHER INIT:. QUIREMENTS /.>COMMENT ............................ . Date Approved - CONSULTANT: Date Sent - FIRE PROTECTION: Sprinklers INIT: 101z7/gy J /,4 INIT: J1JS FIRE DEPT. LETTER DATED: Detectors ( J N/A INSPECTOR: ZONING: REFERENCE FILE NOS.: BAR/LAND USE CONDffIONS? Yes MINIMUM SETBACKS: N- UTILITY PERMITS REQUIRED? S- Yes No E- BUILDING - final review Qc BUILDING OFFICIAL PUBLIC WORKS LETTER DATED: 10 ,2 . Li A �'. Jr , 1 1D —ICf— TYPE OF CONSTRUCTION: INIT: CERT. OF OCCUPANCY? []Yes ),No UBC EDITION (year): 1 REVIEW COMPLETED AMOUNT OWING: 0 CONTACTED • g/F ' �, n Rer DATE NOTIFIED 1 k — 30_ q s init. . 1 -� 2nd NOTIFICATION Q ' 1 _ �7 �� \omO1\ "1 .Qo- - �J BY: (init.Z 3RD NOTIFICATION BY: (init.) 01/08/93 CITY OF TUKWILA Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 .f -0063 BUILDIN PERMIT APPLICATION Division DESCRIPTION:`::::: BUILDING PERMIT FEE PLAN BUILDING SURCHARGE 7:4) TI'f' OTHER: AM. UNT > ATE::,;.:..., .:::::TOTAL SITE ADDRESS -}` SUITE # � 8/1 3 - Of----) S VALUE OF CON ,RUCTION - $ 0-b0 . aD PROJECT NAME/TENANT "0eiit- if 102Cu11 01f,r ASSESSOR ACCOUNT # 1 559 (o0" a -)b (commercial) (FDemolition (building) ❑ Other. TYPE OF New Building Addition LjTenant Improvement WORK: ❑ Rack Storage Reroof ❑ Remodel (residential) DESCRIBE WORK TO BE DONE: Of k0 (Ai=. CNP Poej i ak Rik- Ck:1-' BUILDING USE (office, warehouse, etc.) _ )cESIDL (6(— NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? 43-No ❑ Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: /506 Tenant Space: Area of Construction: OR HAZARDOUS MATERIALS IN THE BUILDING? S stem WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE ❑ Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: ❑ S•rinklers ❑ Automatic Fire Alarm PROPERTY OWNER U PI ! 0 411C," (,.-1 I, j ( -,\ N J PHONE a.i.( ( -- j',' 7 ZIP rf/ b( ADDRESS / g ) .3,S -- CONTRACTOR PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT PHONE ADDRESS ZIP :HEREBY :CERTIFY::THAT I :HAVg. READ :AND EXAMINED: THtS: APPLICATION AND ,KN BE. TRUE AND' CORRE , AAD ..i AM 1Tf (Q 17.Ep: TQ; APPI Y: FAR THIS: PERMIT.: BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON SIGN 'URE PRINT NAME ri()0 s ti _ � L U .r�. - � ft./ (Ai ADDRESS /,;218 3 /f e, ,S -(� (tJ i Af DATE /U• (( PHONE a w� -/))% CITY2IP fe f PHONE 2q/ — /fl6 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the perrnit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. II you have any questions about our process or plan submittal requirements, please contact the Departs T munity Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED (l)-- I°I g L .�, OC T 19 1994 DATE APPLICATION EXPIRES 10/22J03 COMMERCIAL- NEW COMMERCIAL .•BUILDINGSIADDITIONSH, Completed building permit application ;(one for each structure Assessor A000unt Number; wo,sets (2) of the following Specif ication6 Structural'caiculations stamped by a Washington State: license engineer .Solis report :stamped. by a Washington State licensod:en Topographical survey.. Energy calailations;atampod.,by a Washington State •licens engineer, or: architect; n Legal description SUgMITTAL CHECKLIST • COMMERCIAL: TENANT IMPROVEMENT` (r Completed. building • permit application' tenant oca ion of.tenant space s :xisting and:proposed parking andscape;'pion' (i1 applicable Overall bullding plan. Tenant location Use of adjacent (common Wall) tenant �oraII dimensions' of building or square foots Floor ilan of proposed tenant space .. (i Working drawings; stampod by a Washington State licensed ! !. architect, which include • Site plan Architectural drawings: Structural drawings Mechanical. drawings Elevations Civil drawings •:Landscape plan •Tenant, space plan with use'of each room.labell • Exit doors;; egress. patterns New walls,: existing wall, and.walls to .bo demolish Construction details; Cross sections showing wall :construction and attachnient:for floorand calling Structural: calculations stamped )*a Washington State license engineer •may be required if •stnictural work is to be done (2 NOTE ; if any: utility work Is to bo done submit separate: uttGty perm appbcaUon and,piana Completed •utility :permit application( one for entlre project) n Six (6) sets of civil drawings :NOTE .:See utility permitapplcation and checklist for speclfc utili submittal: requirements RACK'STORAGE ,Conpietedbuilding permit application.:: Assessor: Account Number': Two (2) sets of plans; which include; :: [j Building floor plan showing is Entire space where racks. Will be located Exit'doors Dimensions of all aisles Completed building permif:application (one fqr each' Assessor:Account:Number:: ' Nerrative.'descnbing existing roof, matenai boing removed; an material' being':installed NOTE:. A c rrtification.lstter is required poor to :fnal inspection and sign =, off of the' permit ANTENNA/SATELLITE :DISHES Completed building permit; application; Assessor Account: Number: Two (2) sets of plans, which include;: Site Plan. (showing building andlocation•of antennalsatellite:dis Details. antenna /satellite. dish: and method:otattachmon Tenant space floor: plan showing rack storage layout; aisles•and ._-: exits NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over)... RESIDENTIAL NEW SINGLE-FAMILY DWELLINGS /ADDITIONS•:. Completed building permit application: (one for each structure Legal doscription. Assessor Account Number :Structural calculations stamped bya •Washington State license : engineer: may; be required:: RESIDENTIAL REMODELS building permlt:application.; Assessor Account Number Two sots (2) of working drawing's;which include: Site plan --.—p. (tin plan, :show closest hydrant location: •••: Foundation plan Includeepccoss to bulding showing Floor plan width and length of ecciess.) !:Roof plan • • Building :elevations' (all views •.:Building cross - section Structural :framing plans Washington: State.. Energy. Code data permit application Site plan ...Foundation : plan >; Floor plan :R.00f titan;: •;Building elevations °(all: views :Building .cross= section •: Structural framing plans. NOTE !1 any utility work is to be done provide uNhty permit application and plans; must be. submitted REROOF.S -: ,Six. (6) sets of site plans showing utilities NOTE ..•.Building site plan; and utility site plan maybe combined : Soe utility permit .application. and checklist for specifinsubmittal, requlrerr�ents Add:lanai topographical soils tnformahon may: be required if unique. • Completed building permit application :Assessor Account Number ;Naar tivpfdp;;cdbing existing mated poingtinstalled NOTE 4 cart, frcatfan fetter (s required prior off of permit : 4fA4**•AA4 ****k **A4A••kit*, * *fc kk *A * *4kkkAk:Ak* *:1*•4A *4 *A k***4.fr4!r44*4k* CITY OF TUKW]:l.A, 4!A .TRANSMIT *kt k*• 1********* 4**4* 4*** k* 4 **4 *** *'k *:4Ak4*Y7A*•4 *44*k4*-4 k *44!.**44 TRANSMIT Numbers 94001367 Amount: 81.35 10/19/94 13:03 Permit: No: 894 -0369 Type: L3-BUILD BUILDING PERMIT Parcel .Nos 7359EQ -0270' Site Address: 12t311 J5 AV S 10/19/94 Payment Method: CASH Notation: ROMAN TURCHI:NAIK ]:Hite . SAO 4*kkk•44* * *A *kk *kk4•k 4 kk Ai4Agk4* k*: k*A** k*A *A *k** * *•k**4-4**4 *k ****4A *k Account Corte 000 /322.10.0 000 /345.830 000/306.904 I)e cr i pt i on 'BUILDING •- RES • PLAN CHECK -- RES STATE BUILDING.SURCHARGE Total (This Payme!rtt) e . Total Fee Total All Payments: Balance 81.35 81.35 .00 Paid 58.00 18.85 4.50 81.35 GENERA GENERA GENERA TOTAL CASH CHANGE 6636A000 58.00. 18.85 4.50 81.35 81.35 0.00 15:34 INSPECTION RECORiC--• Retain a copy with permit INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ....✓n usn• nom. 4L �, <u'. vl'h '7:tl�uc[i•••'r •• PERMIT NO. (206) 431 -3670 Project: . r r*-1 -rock s R NO Alta"` Pc-YA- 0,1-y Cir w•PL- tl Type of inspeCtion: m aOv4Nt 1 11 6v3WeiL J4A-s A - 9 Address: IA l j� �= J . S . Date called: Special Instructions: C-Pq c," .N), t Date wanted: (1 l q IC47 a.m. P.m. Requester: Phone No.: Approved per applicable codes. Corrections required prior to approval, COMMENTS: 9-4>r wt `r1G'7 Co rurt -txu rJ S I4P'-JGr f_:e- . r r*-1 -rock s R NO Alta"` Pc-YA- 0,1-y Cir w•PL- tl ._ -`1%' % R E 1 el rrotJ CIO ei.tO. m aOv4Nt 1 11 6v3WeiL J4A-s A - 9 1 A Tbk-- .si tm c v, n,� A .,no Is U& I oG t T . nspector: • Date (q/7 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION .RECORD- - Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Bivd., #100, Tukwila, WA 98188 4 . . 5°11-1 —031o9 PERMIT NO. 206) 431 -3670 Pro ect: cAR ! N1� 1=- Type of inspection: F ArVt IN &I rivi : 3s A d Date called ?! AOP ATAIL3 13 Jatri c.LIPS. Special instructions: TO S "PPO f W') j4T • f OD i iiOn/AL Date wante • (,', ! " f a.m. - p.m. Requester: <o MAP Phone No.: Approved per applicable codes. Corrections required prior to approval. COM ENT A i,1 0t4ti R., tD u—s — i W s m_u- P i.72- "LAN), ) o eA 60 , nr` d , ,/q/z-il-Q 500mk -o .6r Nat LED 374 d.c. 61264 (o "d.c. (14)Ae.r `S) i Jc . Aim ,j oiS/ TO e'Ki S71'lG /,liivL.f c fgArnrr.i‘ AT Z' d.c. priAXf'M' '• AOP ATAIL3 13 Jatri c.LIPS. f & (ANNEID (ctie- -) R.e-cnti CA) LA ". ✓hr. 4440 TO S "PPO f W') j4T • f OD i iiOn/AL FitA rr, /r6 w t w rd ." AA NV ."'0 . 4 ADP i-ftwO O d w o s -r0 (-ANT': G r GA 4A8 t"' . AB -f et tA. .. J491C,PrK Yi o« 1171-C' Date: 3/16 $42.00 REINSPECTION FEE REQUIRED. Prier to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: .Date: _'- .d. va...._:.. ss1.^- 't,.:....ci1c.3.s«nbt,1:Zsi,.4 ,. __ INSPECTION RECOR Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 0439%/-ez37 PERMIT NO. (206) 431-3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: , 41 d . . YPe of inspection:i— /./ 1-046v*.• — JI:0 Date called: Project: Dop /7CIA*P7a--•-) c-4-elVt"."46-/- Addre 77-.43,/: / _35 r/4.0....- 50 Special instructions: /?ert,capeel apcfac ,7v C Date wanted: a.m. Requester: w Phone No.: .., Approved per applicable codes. Corrections required prior to approval. COMMENTS: , 41 d . . . . ed,...e..._ - Ad... 4 ,&_., , - '.,.., ,L_. 944 -g or ., w .., IS /e2 '''"2.r./■• 9 C."-- PC- pyvici.44- .400 s Iei-- c ,41,01. 4.9 e,14/1141 „awl. , (le/ frefeasw 744:if LInspector I I Date: 92474,e $42.00 REINSPECT! N FEE REQUIRED. -Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 12, To: Permits From: Joanna Spencer,PW Assistant Development Engineer Date: October 27, 1994 Subject: '\ Carport 12811 35 Ave.S. Project No. P94 -0053 Contact: Roman Truchiniak Phone: (206)241 -1891 Review Comments We completed our review of the above project and determined that no Public Works permits are necessary. Because this project involves property that contains a classified stream, a review from Urban Environmentalist is appropriate. If any questions, please let me know. JS /js cf: Gary Schulz PW Inspector (w /copy of plan) Development File - Cow, r-5 0Y1 fOJ..ECT FORMAT1. City of Tukwila Central Permit SysL11 i - Engineering Division 6300 Southcenter Blvd., Suite #100, Tukwila, WA 98188 jAtIon pplica # r9Li -006 Phone: (206) 433 -0179 UTILITY PERMIT APPLICATION Site Address: Name of Project: I Pro•ert Owner: Street Address: Engineer: Street Address: (LC &t (FIJI �C.(:-(N(AN ✓5 Contractor: Street Address: Phone No.: City / State/Zip: Phone No.: City /State2ip: Phone No.: City /State/Zip: King Cty As RMI:T QUEST Assessor Acct #: 7 3:$ (o - 02 contractor's License #: ('W o 27114 sra- ❑ Channelization /Striping /Signing ❑ Curb Cut/Access /Sidewalk ❑ Fire Loop /Hydr. (main to vault) - No.: _ Sizes: O Flood Zone Control O Hauling O Land Altering cubic yards ❑ Landscape Irrigation ❑ Moving an Oversized Load Est. start/end times' Date: O Sanitary Side Sewer - No.: Exp. Date: ❑ Sewer Main Extension ❑ Private ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑Private ❑ Water Meter / Exempt: - No.: Deduct ❑ Water Only ❑ ❑ Water Meter / Permanent - No ❑ Water Meter / Temporary: - No.: Estimated quantity: Schedule: ❑ Other: ❑ Public ❑ Public Sizes' — Sizes• _ Sizes IATERMETER. EP O SI Tl<;;: » >' ><> ............... EFUND /BILLIN �:ONTH:LX >r itLLiNGS :TO Name: Street Address: Name: Street Address: Phone No.: City /State /Zip: Phone No.: City /State /Zip: ❑ Water ESCRIPTION<`C ❑ Sewer ❑ Metro ❑ Standby PROJECT > ❑ Single- Family Residential ❑ Multiple - Family Dwelling No. of Units: ❑ Hotel ❑ Motel uplex ❑ Triplex ❑ Apartments ❑ Condominiums ❑ Other: ❑ CommerciaVlndustrial ❑ Office ❑ Retail `'MISCELLANEOU INFORMA:TL 0 New Building Square eia J Footage' ❑ Warehouse ❑ Manufacturing Remodel/ Addition King County Assessor's valuation of existing structures: ❑ Church ❑ School /College /University ❑ Hospital ,'Other: Square footage of original building space: VY ) Square footage of additional building space: c /yC1 Valuation of work to be done: $ I. HEREBY ;CER.T • :. H • ERI AD TNISAPPL ICAT ION 'AND: KNO�!I! THE:; :B. . TO BE Tl,1UE: AND<CORRECT Applicant /Authorize. ---- _Agent Signature: �- Contact Person • (print name)' •• Address: / ? I ( Date Application Expires: •--' 1 U C Mi 1 ? (. !'. ) s-: 11 4-LL7 - Phone: 4- (1--q4 Print Name: J Qc v l PJ A Phone: cgfin.Egatia ocr 1 9 1gsa Date: )a ( '•e/ -+. Date Application Accepted: PERMIT CENTER 04/22/92 March 1, 1997 City of Tukwila FILE COPY John W. Rants, Mayor Department of Community Development Steve Lancaster, Director Roman Turchinaik 12811 35 AV. S Tukwila, WA 98168 RE: Permit B94 -0369 Dear Mr. Turchinaik: On October 30, 1995 an extension for your permit B94 -0369 was granted for 180 days. As of May 13, 1996 no further inspections have been made. Due to the lack of progress on your project and inspection progress your permit has exceeded the 180 day extension and is no null and void due to expiration. No further extensions will be granted. Due to the expiration of your permit as of March 1, 1997 this permit is now closed without the benefit of a final inspection. Any further work on the project will require a new permit application submittal and additional fees. Any new submittal will require compliance with the current edition of the Uniform Building Code. If your project has been completed please contact the permit center for proper closure procedures. A final inspection and approval is required. If you have any questions or need further assistance please contact Kelcie Peterson at the City of Tukwila Permit Center at (206) 431 -3672. Sincerely, Kelcie Peterson Permit Coordinator sent certified mail #P 588 827 447 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 (206) 4313670 • Fax (206) 4313665 P. 588 82? 447 Postal Service "rieceipt for Certified Mail No Insurance Coverage Provided. Do t use for International Mail (See reverse) Se rte Au s Pgst tige, S1p�, (,1 � Postage t�(, $ Certified Fee Spode! Delivery Fee Restricted Delivery Fee Retum Receipt Showing to Whom & Date Delivered Rehm Receipt Slowing to Wham & Addressee's Address JTAL Postage & Fees . $ d . cc> Pos marts r Date viic, 014 1>511)(i41" Stick postage stamps to arllcte to cover First -Class postage, certified mall fee, and charges for any selected optional services (See front). 1. If you want this receipt postmarked, stick the gummed stub to the tight of the retum address leaving the receipt attached, and present 'the article at a post office service window or hand it to your rural carrier (no extra' chi 2. If. you do not want this receipt postmarked, stick the gummed stub to the right of the return address of the article, date, detach, and retain the receipt, and mall the article. 3. ,If,.you want a return receipt, write the certified mail number and your name and address on'a retum receipt card, Form 3811, and attach it to the front of the article by means of the gummed ends 11 space permits. Otherwise, affix to back of article. Endorse front of article RETURN RECEIPT REQUESTED adjacent to the number. .. 4. If you want delivery restricted to the addressee, or to an authorized agent of the addressee, endorse RESTRICTED DELIVERY on the front of the article. 5. Enter fees for the services requested in the appropriate spaces on the front of this i( receipt. If return r ipt is requested, check the applicable blocks In item 1 of Form 3811,,,. 6. Save this rect rd present It it you make an Inquiry, PS Form 3800, April 1995 (Reverse) ( *try or _• r)KwILA DPT..,, 0 F (o -iw\ DEvELoph ar f - eQ�'f be Q.x dd ct gia � v. 6 cQl %Ci . tirur tier i �c /..�i�d.h11'a�t -ibis 'U5/c fl STN f`r� cog -ear 04.11 701g742PC r :ern W m-s `wcolQ. 0-71 /M c:J lZ ! l 777) lam... / % 6" c 64 ce......%c & &b k `t E iZ ti IT ,.69-1)36g 1u F / A -NC' AL odGI4Ari PS .41-) `7-zs d z-n Q S r .L //A-145p J7~... 1-141 e 'TitiG OR FlN ANCES . j c .C°/,47 .&:: 1-tY. "2 AS 7.I ie.kr w/t-Y . As . - Aim.) L /,lAv ,c/xs o . #411•1 . C4eA E. c Pr.. ,. o. sT ....._ode.,144:776Ads: 4)/4( de . . . 1 4 E . 7-0. 045U Lo C O L,O eiQ ()mix% AT £ F'o{� /10 DVS . r ; ,. _..IF You. APR 11 1996 COMMUNITY DEVELOPMENT City of Tukwila John W. Rants, Mayor Mar 05, 1996 Department of Community Development Steve Lancaster, Director ROMAN TURCHINAIK 12811 35 AV S TUKWILA, WA 98168 RE: TURCHINAIK ROMAN Dear Permit Holder: Our records indicate that on Apr 18, 1996, one hundred and eighty days will have passed with no inspections having been called for under Tukwila Building Permit Number B94-0369.' Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Apr 18, 1996. If your project has been completed please call for final. If you are actively working on it please notify our office. If you have any questions or need further information to obtain an extension on your permit, please call the Tukwila Building Divison at 431 -3670. Sincerely, /4e/eza2 /ee,t6(922 Kelcie J. Peterson Permit Coordinator Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 41313670 • Fax (206 ) 4313665 October 30, 1995 City of Tukwila John W. Rants, Mayor Department of Community Development Steve Lancaster, Director Mr. Roman Turchiniak 12811 - 35th Avenue South Tukwila, Washington 98168 Dear Mr. Turchiniak: RE: Extension Request for Tukwila Building Permit #B94 -0369 A one hundred eighty (180) day extension to the above referenced permit is hereby granted. Please be advised this is the only extension that will be granted for this permit. If substantial work is not started on this project by April 18, 1996, Permit #B94 -0369 will become null and void on that date. If you should have any further questions on this subject please feel free to contact the Permit Center at (206) 431 -3670. Sincerely, Building Official /kb 00 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 (206) 431.3670 Fax (206) O1.=3,665 ( (ter majc. /60'201 iRMA xL LA . ) 9 i/ b_ Y 4,-)4,1-.6 4li1'if :, ■—, ir , you 6-) 0 Ta n Pe ?..►`„r:, q -634. Ct _2- / /kU6ti/ RAO € 'Ti '`t 70 ... DO ry u� -fit 6-) g_ . _.. 0 1w -rrk ?Ro S-e: .So km Soo p .1771$ R- w/!, .y)rr jii Lt !N6. LAST /tin -. 777$1 4i.& .....60Y . _.T�'o.. FMT . ' I!•t A . ... �� Q 5 ...... �R4 U2 � 5 "I ► �u °S� ('-- . ! ?.1'��' _ .... t1 Ark $ .... I. ° ... , c'' (� � T . _. vC /Z 6 C.Y ... °NI-l7gb t << I r-n ?t7 t, RECEIVEi ►. - OCT. -2-3 '1995 coMMUNITY DEVELOPMENT" Sep 11, 1995 City of Tukwila FILE COPY John W. Rants, Mayor Department of Community Development Steve Lancaster, Director ROMAN TURCHINAIK 12811 35 AV S TUKWILA, WA 98168 RE: TURCHINAIK ROMAN Dear Permit Holder: Our records indicate that on Oct 21, 1995, one hundred and eighty days will have passed with no inspections having been called for under Tukwila Building Permit Number'B94 -0369. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Oct 21, 1995. If your project has been completed please call for final. If you are actively working on it please notify our office. If you have any questions or need further information to obtain an extension on your permit, please call the Tukwila Building Divison at 431 -3670. Sincerely, • 11/,e1C4-ei ‘7°,-&t-e(7 Kelcie Peterson Permit Coordinator Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 431.3665 BUILDING PERMIT # B94 -0369 BUILDING DIVISION NOTES The following list of building code requirements are evident from the construction plans submitted with this application. These requirements in addition to any other code requirements discovered upon field inspection shall be conditions of final inspection approval for this permit. 1. All frame wall sill plate material shall be of treated wood or approved wood of natural resistance to decay. Foundation sill plates shall be bolted to the foundation or foundation wall with not less than 1/2 -inch nominal diameter steel bolts embedded at least 7- inches into the concrete and spaced not more than 6 -feet apart. There shall be a minimum of two bolts per piece with one bolt located within 12- inches of each end of each piece. A properly sized nut and washer shall be tightened on each bolt to the plate. 2. Exterior frame walls and interior bearing wall shall be braced to resist wind and seismic forces in one of the methods prescribed in UBC Sec. 2517 (g) 3. Refer attached copy. 3. Common wall between new garage and dwelling must be protected on the garage side with construction as required for one hour fire rated construction. At minimum 5/8" Type "x" gypsum wallboard finish on garage side is required. Door which provides access from the garage to the dwelling must be (at minimum) a self closing tight fitting solid wood door 1- 3 /8- inches in thickness or a self closing tight fitting door having a fire protection rating of not less than 20 minutes. 4. Plans indicate a roof framing plan with 2x6 rafters @ 16- inches on center. The spans and spacing of these members are adequate for a 30 lbs. per S.F. live load and no ceiling load. This framing is not adequate for a future deck load as noted on plans. 5. Exterior wood stud walls shall be covered on the outside with a material as specified in UBC Sec. 2516 (g). Studs or sheathing shall be covered on the outside face with a weather - resistive barrier when required by Section 1708 (a). Refer attached copy. 6. Roof coverings shall be secured or fastened to the supporting roof construction and shall provide weather protection for the building at the roof. Roof coverings shall be in accordance with the provisions of UBC Chapter 32. 7. All code requirements that are not specifically listed herein or are not noted on the construction drawings shall be subject to field inspection. CITY OF TUKWILA APPROVED NOV 3 AS 1994 BUILDING DIVISION • 1991 UNIFORM BUILDING CODE 2517 The plate shall be continuously tied at joints by solid blocking at least 16 inches in length and equal in size to the plate or by 1/8 -inch by 11/2-inch metal ties with spliced sections fastened with two 16d nails on each side of the joint. ' • Studs shall have full bearing on a plate or sill not less•than 2 inches in thickness having a width not less than that of the wall studs. • 1 3. Bracing. All exterior walls and main cross -stud partitions shall be"effectively and thoroughly braced to resist wind and•seismic forces 'by,'one;'of,tijir;folliiwiri methods: ''T.'5'minal 1 -inch by flinch continuous diagonal braces let into top and bottom plates and intervening studs, placed at an angle not more than 60 degrees or less than 45 degrees from the horizontal, and attached'to the framing in conformance with Table No. 25 -Q. 'II,. Wood boards of 5/8 -inch net minimum thickness' applied diagonally on studs spaced not over 24 inches on center. .C. Plywood sheathing with a thickness not less, than s /ib inch for,16 -inch stud, spacing and not less than '/s inch for 24 -inch stud spacing in accordance, With Tables. Nos, 2541-1 and 25 -N =1. D,. Fiberboard sheathing 4 -foot by 8 -foot panels not_less,Ahpn 1 /2inch thick applied vertically on studs spaced not.over 16 inches on center when installed in accordance with Section 2514 and Table No. 25 -P. , ;,,; • E,.Gypsum board (sheathing 1/2 inch thick by 4,feet wide, wallboard.or veneer base), on studs spaced not over 24 inches on center and nailed at 7 inches on center. with nails As required by .Table No. 47- I,,.,, ,., , ,. F Particleboard wall sheathing panels shall be in accordance with Table No., 25 -N -2. G. Portland cement plaster on studs spaced ,16inches on center installed,in ac- cordance with Table No. 47 -1, • H, Hardboard panel siding when installed in accordance with Section 2516 (g) 6 and Table No, 25 -0. For methods B, C, D, E, F, G and 11 the braced panel must be at least 48 inches in width, covering three stud spaces where studs are spaced 16 inches apart and cov- ering two stud spaces where studs are spaced 24 inches apart. • .. ,. i i, . • • t All vertical joints of panel sheathing shall occur overlstuds..Horizontal joints shall occur over blocking equal in size to the studding except where waived by the. installation requirements for.the specific sheathing materials: ::. • The location, type and amount of bracing shall comply with Table No. :25 -V. 4. Cripple walls. Foundation cripple walls shall be framed of sttidsnot less in size than the studding above with a minimum length of 14 inches;•or shall be framed of solid blocking. When exceeding 4 feet to height, such'walls shall be framed of studs:having the size required for an additional story. . Such walls having a stud height exceeding 14 inches shall be considered to be first -story walls for the purpose of determining the bracing required.by Section' 2517 (g) 3. Solid blocking or plywood sheathing may be used to brace cripple walls' having a stud height of 14 inches or less, 285 CITY OF TUKWILA APPROVED ... . NOV ,. . 3 0.:1994': A$ NOTED. • BUILDING DIVISION 1991 UNIFORM BUILDING CODE 2516 For fireblocking of wood floors on masonry or concrete floors, see Sections 1804 and 1904. ' For fireblocking ceilings applied against noncombustible construction, see Sec- tion 4203, Item 1. For penetrations of fire- resistive construction, see Chapter 43. (g) Exterior Wall Coverings. 1. General. Exterior wood stud wallsshall be covered on the outside with the materials and in the manner specified in this section or elsewhere in this code. Studs or sheathing shall be covered on the outside face with a weather - resistive barrier when required by Section 1708 (a). Exterior wall coverings of the minimum thickness specified in this section are based on a maxi- mum stud spacing of 16 inches unless otherwise specified. .. 2. Siding. Solid wood siding shall have an average thickness of 3/8 inch unless placed over sheathing permitted by this code. Siding patterns known as rustic, drop siding or shiplap shall have an average thickness in place of not less than 19/32 inch and shall have a minimum thickness of not less than 3/8 inch. Bevel siding shall have a minimum thickness measurcd at the butt section of not less than 7/16 inch and a tip thickness of not less than.3 /16 inch. Siding of lesser dimensions may be used, provided such wall covering is placed over sheathing which conforms to the provisions specified elsewhere in this code. All weatherboarding or siding shall be securely nailed to each stud with not less than one nail, or to solid 1 -inch nominal wood sheathing or 15/J2 -inch plywood sheathing or 1/2 -inch particleboard sheathing with not less than one line of nails spaced not more than 24 inches on center in each piece of the weatherboarding or siding. Wood board sidings applied horizontally, diagonally or vertically shall be fas- tened to studs, nailing strips or blocking set at a maxitnum 24 inches on center, Fas- teners shall be nails or screws with a penetration of not Tess than 1 1/2 inches into studs, studs and wood sheathing combined, or blocking. Distance between such fastenings shall not exceed 24 inches for horizontally or vertically applied sidings and 32 inches for diagonally applied sidings. 3. Plywood. When plywood is used for covering the exterior of outside walls, it shall be of the exterior type not less than 3/8 inch thick, Plywood panel siding shall be, installed in accordance with Table No. 25 -M -1. Unless applied over 1 -inch wood sheathing or 15/32 -inch plywood sheathing or 1/2 -inch particleboard, sheath- ing, joints shall occur over framing members and shall be protected with a continu- ous wood batten, approved caulking, flashing, vertical or horizontal shiplaps; or joints shall be lapped horizontally or otherwise made waterproof. ' 4. Shingles or shakes. Wood shingles or shakes and asbestos cement shingles may be used for exterior wall covering, provided the frame of the structure is cov- ered with building paper as specified in Section' 1708 (a); All shingles or shakes attached to sheathing other than wood sheathing shall be secured with approved corrosion- resistant fasteners or on furring strips attached to the studs. Wood shingles or shakes may be applied over fiberboard shingle backer and sheathing with annular grooved nails. The thickness of wood shingles or shakes between wood nailing boards shall not be Icss than 3/8 inch. Wood shingles or shakes and 279 1 :, tTY. •O F .i'Uf WII:A : . l'/ {•j ti 1991 UNIFORMWBUILDINO CODE asbestos shingles or siding may be nailed directly to approved fiberboard nailbase sheathing not less than i/2 -inch nominal thickness with annular grooved nails. The weather cxposure of wood shingle or shake siding used on exterior walls shall not exceed maximums set forth in Table No. 25 -L. 5. Particleboard. When particleboard is used for covering the exterior of oiut- side walls it shall be of the Exterior Type 2 -M grades conforming to U.B.C. Stan- dard No: 25-25. Particleboard panel siding shall be installed in accordance with Table No.'25 -M -2 and Table No. 25 -Q. Panels shall be gapped l/8 inch and•nails shall be spaced not less 'than 3/8 inch from edges and ends of sheathing. Unless applied over 3/8 -inch net wood sheathing or V/2 -inch plywood sheathing or t/2 -inch particleboard sheathing, joints shall occur over framing members and shall be cov- ered•with a continuous' wood batt; or joints•shall be lapped horizontally or'other- wise made waterproof to the satisfaction of the building•official, Particleboard shall be sealed and protected with exterior quality finishes. ; 6. Hardboard. When hardboard siding is used for covering the outside of exteri- or'walls, it shall conform to Table No. 25 -0. Lap siding shall be installed horizon tally and applied to sheathed or unsheathed walls. Corner bracingshall be installed in conformance with Section 2517 (g) 3. A' weather-resistive barrier shall be in- stalled under the lap siding as required by Section 1708 (a); ' Square -edged nongrooved panels and shiplap grooved'•or hongrooved•'siding Shall be applied vertically to sheathed or unsheathed walls. Siding that is grooved shall not be less than' /4 inch thick in the groove.' '' Nail size and spacing shall follow Table No. 25 -0 and shall penetrate framing 11/2 inches. Lap siding shall overlap 1 inch minimum and be nailed through both courses and into framing members with nails located 1/2 inch from bottom'of the overlapped course. Square -edged nongrooved panels shall be•nailed 3/e inch from the perimeter of the panel and intermediately into studs. Shiplap edge panel siding with 3/8 -inch shiplap shall be nailed 3/8 inch from the edges on both sides of the shi- pinp. The 3/4 =inch shiplap shall be nailed. 3/8 inch from ttie'edge•and "penetrate through both the overlap and underlap. TO and bottom edges of the panel shall b'e naile'd'3 /s` inch" from the edge. Shiplap and lap siding' shall not bp 'force fit. Square -edged panels shall maintain a '/16-inch gap at Joints: All joints and edge's of siding shall be over framing members, and shall be made resistant to weatherpene- tration with battens, horizontal overlaps orshiplaps'to the satis(action"of the build- ing official. A 1 /s- inch gap shall be provided around all openings.' ' '" • 7. Nailing. All fasteners used,for the attachment of siding shall be of a corro- sion- resistant type. ' (h) Structural Floor Sheathing. Structural floorshcathing shall be designed in accordance with the. general provisions of.this code and the,special provisions in this subsection. ' Sheathing used as subflooring shall be designed to support all loads specified in this code and shall be capable of supporting concentrated loads of not less than 300 pounds without failure. The concentrated Toad shall be applied by a loaded disc, 3 inches or smaller in diameter. . • • • ,_' • ; CITY. OF TU W1 LA: :. •'PROVED' Qi•'3 tj '19911 AS..t Ot.hli glJll -QI�JG DIV1$t0N: • 0 b vi oo '5 ,°'ra, b a= .1 d ° y u 8 0g Ep 3 5 e °: •••• r .app .. "�' 'OJ N A o w u •5 C GGyC .: h'S y� $ -'g 9 4 to r G"r N . N y •° v C ..... GO v ° . O V O '� 00 '_. I.u. o 3 z G .0 w e Z 3 G u C u $7 u 3 H 5 ., ro 4 a 3 E• .@ vb -2" v; o a c.4: vi 'D o ° 3 .4•° y •o o u o I•, •a g u E. u o h C u u g w q u o 0 • E a g ir , 0• A �w K .y o8 a °° � ° ° Sva ° u Ya u•5 a�, o-0 ub uc2E •g g A$d. •[ > � $ c E $ Ec Q o o E 3 ro a8 • W u u , w o u „ 4) .0 o ° '. A o u yE Saqq u w 0 y eu E , °'oaw. iu A t > up % t.. us) 4). p2 •3 u ° •._ a w >., „' E E d u E 4) E 5 n. c V 'S "d ' ° :6v>E c C^ ° S o e, 0 . CO o o .c C a= u s 3 w u. y u ., § °c v ° b C7 u . 8v: .0 .0 ' " b 0o " ° o e o 2 ° o E ° � .° u ° E o E Ili ° oa b e 4 � 'o ° o 3 S , ° ° .c u a. o u E o 0 c - R * '''' E ° A E c q '46 ] y u R. . p - O H w >. C y u .5 ` p to ' N v1 � r O u u lO u ro a t. C d i >, N o u o C v , 2 w O A .a 3 z,' b 4) C 4; s G. .. •p �• ° 'E [ > c .5 w H p ° N 5 o g a a "11 u u r ° u o u o z x = A E.' a C yF Lo Ty 4 J � G L 10 A ¢ ° O u 2 t r- 1 e ° E o }a- E- u C I,., .. u w p � a p ° UO 3 G O h O y 3 Y g . 1. .e N'O 5 QIIIH 00 C 'p ..• O C , G 0 gc 'O 3w 5 �Q .G E u '., m i m o G. u 3 c. e. •o w s. 0 Q, A 1 V W 3 u 0 = CU a= 0 b°" o0 0 N co Q a G � w . • 0 c o m oy w v¢Cre3A o �z > e -G n � inQ t co u .$ 0.1 u A u A G D. S a w O41 WO °a u 3° '� co co r y N O A .. �/ u to N y .10 N 2 O 4. N rn u G 4. •E N q 1991 UNIFORM BUILDING CODE u 0 O .>l d � N b �� .dam 0 N 2 O A ^ i 'y ci y V o v., � a t VI c A 0 vi =8. 6 43`4 o p 2),9'.54) ° o crS . N .1 :4> o• .0 N. •S en F N �C 131) 0 .c . A N a) ° b C 0 3 .o E gal C ,w ° 3 v .o b (5 0 5: v a) . u °+ ,>y ,_,= 8. 5 Ti; 2 .d N ;j . ro 5 '0 E ,r, 2$ Cwu H .5 o .a.- 0. �� N u e E c �aw V En oM,•u a.s, .c A E' S tl• IV in 8 r Q C u >. v U 0.00 4) §G e O❑ ° 5t c le 8 Ern in 0 g 'g u O 7� a y 5 o a) , A ° o ° N > ° p • n . ' � y A S 1. O am0. �2 y 'O 0 CG C • ,y . � _ N 'v _ g a b u •S x ,, . ° 4). ? g H y o 1 .p V W « . '° ti ° « � C ~ c u yu o C M D 0 E 4)w 4) «s J °4 - Q J u 15 >., 00 E aE °' vO oE> •5u v 25 0.7E0 .o> oeoL u N a= k. A p o' • 2 8 s v u � g . E 3 E O ' •U N.° w@ N i a t. 1121.! °c , o i . cn r u C .,o ° °` II 8 ca uI « u 0•Nb a >.: c u oy. o °mi v o , c a .�q ° > : w o c w E j •G N . O oy.N .a o a u'C E E $... ^ 2. a u° K c • b>.; >..e O 04k z �Q ... 4..A .c E.�G'CV�Ahro�yb°3c° Eo�?rc 7 °C j al N C 0 T 4. R. W a u . - ,° G c y v) 0t) a4 U^ 0." .0 :A u y u' « 0� w 0 03 ! .O. o • 3 c E u ,,, '5 u N O U h N •E .: C 'G cg co WNgm y ,uo ... ., r-: a 2 i cd n co okbpu .. .cEu uo$ =ko- vt E4g H "'- �o ° A >,o d oo $ ` (1) E w °>:•E o $ E do •N.E 3 O E S °C•o • ._,3.c • E.1" A A s a4 7 u o > 4a; °u u u .yy Tl .o > C . i3 u �O °o.$ 0°Q •° V w c Ayy CCC S u g Llfg 76: pq E ° a. v O ° w $ Q • obi ' b0 :: 48 O u - tf A'SU'C u ^ 6F•.1 Cam. C .'. 4,,, > .c N . u .A o o 'N Ca, O. o .> H • u 13 c cz..S a o° u[ is dJ4) bEE' °803 cvri Cu GI) > �.- • r-"I LE COPY Pitta Check c - sub; .-.,1 omissions c:-., r.ct c. : .:.prize the violation c. ...., adopt:xi cc: c cr ordinal o . !Receipt of contractor's CQprter u ^ ^rovc pi Date Permit No. NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL OF TUKWILA BUILDING DIVISION. NOTE: REVISIONS WILL REQUIRE A NEW PLAN SUBMITTAL / 4ND MAY INCLUDE ADDITIONAL. o AN'REVIEW FEES. S µPARATE PERMIT I /M= L CHAN!!3A GL ECiE,CAL ❑ PLUMBING ❑ GAS PIPING CITY or TUKVVILA BUILDING DIVISION i /00 3s4-11 A CITY OF TUKWILA APPROVED ad'// 3s 14 Ave s NOV 3 0„1994 AS BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 19 1994 PERMIT CENTER £ s) c, couc.. wAu. STCEL XXIS ?lv4 3ti g1'L 7 CoPc, .S't.N6 .$ 1 611 ais-noet tout. eau I a/7 • 4 CITY OF TUKWILA APPROVED NOV 3 0 1994 AS NOTED BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 19 1994 PERMIT CENTER 006 t W&C 1NTER.%c L WALL~ �G r alyr • Ov62 *Wk. P4 grroF (Fu-i. accK � CITY OF TUKWILA APPROVED NOV 3 0 1994 AS NOTED BUILDING DIVISION 0c RECEIVED CITY OF TUKWILA OCT 19 1994 PERMIT CENTER w 11 ,�. - 01)-717—( . . I . 1 a Lt II - J 006 t W&C 1NTER.%c L WALL~ �G r alyr • Ov62 *Wk. P4 grroF (Fu-i. accK � CITY OF TUKWILA APPROVED NOV 3 0 1994 AS NOTED BUILDING DIVISION 0c RECEIVED CITY OF TUKWILA OCT 19 1994 PERMIT CENTER a- -aYbA-io 2S-t-(1 s slog D o u 4 L i r //6q g J �. 7.476.4160 .trs/ SJtc. CITY OF TUKWILA APPROVED NOV 3 0 1994 AS NOFEU BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 19 1994 PERMIT CENTER