Loading...
HomeMy WebLinkAboutPermit B94-0440 - SOUTHCENTER PLAZA - CORRIDOR, DEMISING WALLS AND DOORSCity of 71ikwilL (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B94 -0440 Type: B -BUILD Category: ACOM Address: 14900 INTERURBAN AV S Location: Parcel #: 359700 -0006 Zoning: C2 Type Const: V -N Gas /Elec: Wetlands: Water: N/A Contractor License No.: DAVISSI105PN Status: ISSUED Issued: 02/08/1995 Expires: 08/07/1995 Suite: 275 Type of Occupancy: OFFICE Slopes: Y Sewer: N/A TENANT SOUTHCENTER PLAZA 14900 INTERURBAN AV S, TUKWILA, WA 98168 OWNER SOUTHCENTER PLAZA Phone: (206)455 -9981 EQUITROL INC - AGENT, PO BOX 40089, BELLEVUE WA 98004 CONTACT FRANKLIN TSENG Phone: 206 455 -1950 C/0 SUHRCO MANAGEMENT INC., 10655 NINTH ST, BELLEVUE, WA 98004 CONTRACTOR DAVIS SCHUELLER INC. Phone: 206 787 -1059 15620 HIGHWAY 99, SUITE 16, LYNNWOOD, WA 98037 ********************** ** *alt ** *********** ***** *** k********** ** *** **** **** **** Permit Description: EXTEND CORRIDOR, ADD DEMISING WALLS AND DOORS. Units: 001 Buildings: 001 Fire Protection: SPRINKLERED UBC Edition: 1991 SETBACKS Front: .0 Back: .0 Left: .0 Right: .0 Valuation: 10,000.00 Total Permit Fee: 197.55 ********************************************* * * * * * * * * * * * * *•k * * * * * * * * *'k * * * ** a\egpaA pkw - -- a-`5 45 Permit Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature: -J1sA. b Date: 0,2/ 0S- Print Name:___J, /-LE5 %QCK6UiEGEg Title: 'IEC12 supcieviSC This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. All PERMITS ISSUED FOR NEW CONSTRUCTION, REMODELING, OR DEMOLITION PROJECTS REQUIRE CONSTRUCTION, DEMOLITION AND LANDCLEARING WASTE MATERIAL FROM THESE PROJECTS TO BE RECYCLED AT A KING COUNTY LICENSED OR APPROVED FACILITY, OR TAKEN TO REGIONAL DISPOSAL FACILITIES. CITY OF TUKWILF Department of Community Development — Permit Center ' 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER q4-- 000 INSTRUCTIONS TO STAFF 0 Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. ® Plan corrections shall be completed and approved prior to sending to the next department. ® Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. O Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMENT.! BUILDING - initial review IRE O PLANNING DATE ,PROV.E QUIREMEN' MIVIEW I/ RS—I R UTED CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: f1 Sprinklers fI Detectors INSPECTOR•1aR:7Q N/A INIT:° l-5k9 FIRE DEPT. LETTER DATED: / INIT. ZONING: IBAR/LAND USE CONDITIONS? REFERENCE FILE NOS.: MINIMUM SETBACKS: N- S- E- O PUBLIC WORKS O OTHER Nft UTILITY PERMITS REQUIRED? ( ) Yes U N INIT: PUBLIC WORKS LETTER DATED: O BUILDING - final review O BUILDING OFFICIAL INIT: INIT: IN TYPE OF CONSTRUCTION: CERT. OF OCCUPANCY? [Yes 'No UBC EDITION (year): . REVIEW COMPLETED AMOUNT OWING: 5-0 CONTACTED L-0 ` -- �Y� -Q- DATE NOTIFIED 11)3 —r-, �. (Y:) t� (init. BY: (init.) 2nd NOTIFICATION 3RD NOTIFICATION BY:. init. 01/08/93 CITY OF TUKWiLA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER BUILDIk3 PERMIT APPLICATION DESCRIPTION BUILDING PERMIT FEE :': PLAN CHECK FEE !` BUILDING SURCHARGE: TOTAL AMOUNT' .a =NMfir ?�o� DATE— SITE ADDRESS SUITE # louv 1 fr,f1g2 i-ei) ,Az-6—S. 275 VALUE OF CONSTRUCTION - $ ` i a, dLK PROJECT NAME/TENANT 0(rt h C&rt P iG fiK6 71,h0Pireir. ASSESSOR ACCOUNT # 3 053/ "' .J (co mercial) L) Demolition (building) 0 Other. TYPE OF 0 New Building U Addition LO'fenant Improvemen WORK: O Rack Storage 0 Reroof C) Remodel (residential) DESCRIBE WORK TO BE DONE: rs6f6 Car 42- 00K, Acv P, is,i-fc, w/at -c ,t Pares . BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: a l- ark requirements may need to be met. Please explain: WILL THERE BE A CHANGE IN USE? 2-No 0 Yes If Yes, new building SQUARE FOOTAGE - Building: 56, $3 cF Tenant Space: j., .ftesi4-50bArea of Construction: ..zoujsf, WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? (--'o 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: LVS•rinklers r Automatic Fire Alarm S stem ADDRESS PROPERTY OWNER 197.6- pia, th/Sy1 ,>✓e-47 Ci4v1 PHONE Sc /yg.tl ADDRESS c 6 S(/HR -co ,�nar�t�t /,.Jc. t f065S NL-4' -C -'�7 --• ( 05-9) L,„ NAAjo- O /t) L / PHONE 7g7.../D59 e-.J EXP. DATE Kan,, ZIP �637 CONTRACTOR gezPS Ste, eo( ,1 UL� 8 ADDRESS i5` 4 1f1 r', -9- (� c, WA. ST. CONTRACTOR'S LICENSE # ► , JA. 5 $' ot� FIN\ ARCHITECT r 111,64)-1/\1 . ( C L . P{„/t,l--- R3 PHONE �� 53 G ZIP (.1. ADDRESS l A _ . I HEREBY ..CERTIFY THAT I :HAVE; READ AND :EXAMINED :THIS:APPLICATIOWAND KNOW;THE SAME .TO. BE TRUE AND CORRECT, •AND I AM'AUTHORIZED TO APPLY'FOR:THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE _ DATE /ZO /yY- PRINT NAME "� ✓� /�L`.J .S� PHONE /LIP PHONE ,r �� l S� 9 ADDRESS Franklin Tseng 57/9;,,E ,3CI�TY CONTACT PERSON Reat- Estate ratlarus -Mgr. SUHRCO Management, Inc. u-wr %or APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by tiie applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Departmenhgmunity Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES _zip 4, e,ADEC 3 0 1994 PeRMiT CENTER (p- ?)D ---q 10/2209 COMMERCIAL NEW COMMPRCIALBUILDINGS/ADPITIONS:::::......:. SUthiVIITTAL CHECKLIST ••••••••••••••••• COMMERCIAL TENANT . . ....... „ ....... ......„ . ........................ ........ completed..bUilding Permit applicationS(onajOr,:eacb,.atruCture • ' Specitications Statallcons. onginoor ..; • " • " :"•••••••,....„.•„.•„.••••••-•••••-•,...„•••• ..•:,„ ...• oils,rePOrt•:itarriPadby...ti,WaShingtOnSiale:IfiCenSei;f:•Origiear. •;TabographiCar survay Assessor 46644 Numbor ii',o•,'.t''.:tt,.)%'.iai.:;::,':',..,P::.',I::.'•c:''PT.i':'''''''.$1•.'i•i'''.:'°'''ti..':.:4'..F''...::]:::°:::Is:''Ci':••::::'::.::!):..•.;',.::.:::;:''j:::;::'v.:.::..:lh.'I'61'.i.16.*j •„................„..................... . ' -••• Location ...of::tenant apace.:,.'.,„ -.Xlit16ii:.*.10iO4?00i610 ri r.1.0sca p9: plan (11 i 4 Ui:::.::...:.:..',.;::::::::::'•,!:: Ove ..!.•:.!':a....4:'.....,• ,:.',:i•I:.::::'.....:....' ...:..,.-...i•.:'....'i...... ..).„,!.0.,...'....i...,..,6‘:..E..:.:.i..':'.g:):7,To0:Ipoie.'0,.. '.:....'x00 UO of a d::0:6:k 9. :.,.:. :..E.... . ,. f :.::•:s.•.:.::.::.t,', i. n;.....::....i..:.... :..:o..::....:.''..::.. .:.t:.:......u:...:'..i. .a....'.':„r1••::;..-.1:O'..*...:..!:.......:,..:,O...„..:....:.::':.........0..•...e.:„... ..:::.i,... ..,.6i.:i.i..:t.s„.,..,i........, .„.., :......c„.r:art i i:. i' .. buildni ei00:.:1;:106:cf.!1nn "T;intP:1; .4:ii:a;:t°, :.:, :..:::::..,:I:.r,...i.•i....:',9i.,':,.•0....:.:.:.p::.;.... : iabeiied „.t.?..:. : 9 • Exit 1,andwc.pa,io:. :::.l .:: :...;,:.1::!.•.:)(•,..•..sb ,...e:..:... .. e Construction dei1s and '6tiu:rai661cai9;s;n'y':;;h!ib1:si:11. .::: 6.•...: °r::i4qujd NOTE 119 be d5i4i:subi i:0oa:P.!i14ermit:::..,:.::::::::::::::::::::: :..:.„:... ... 1:::,0OPfiCatio•ka0.d.iii,an'a.:::::.::::::::::::,:::::::.,:•:•,::-.•:„..... ::::::::•::::::::::::::::::::::-:•:•::::•::•::::S:::::::•::a:::::•.:•::•::V•:::•:•::::::•:•:::::::::•:•::::::::::•,:::':::::::a:.::::::::...... . . .. „ . . . . . . . stamped by d'WaShingtorti.State,:tiCens :engineer. or architect • . : : ..Legat'deScriOnon:.:..:::.::...:::::....:-.:',.....:::,:-..„,...........:-.....„........„:,:„...:...,.....,.....................,:,..............„. ...:. .• ..::........ . .:.:: . ::::::::•::.....:,..........„,:::..:::::„.......:::......:::::::.„:::::......::::::::::::::::::::::::::•.::::::::::::::::::::..:-.:::::::::::::::::::::::::-.::::::::::..........:,........... 1 I.:Woriiing:drawingS; StaMPadby.a:WahingtO:.Stata•:licanad... —l.:•architoct,:whichinclude::::::::::::::::::::::..::::::::::::::::::•:::::::•:::::;:•::::::::,::::::::„:::::::::::::::::::::::::::::::::::::',:::::::::::::::::::::::0:::::::: • .::::: :: :-........:1.....::::,"L:f 01t :•-...,.....i::::::::::::::::::::::::,:::::•?,::::::::::::.::::::•;-•::::::::::::•;••••,:.,:::::'::.:::,:i:::::::2::::::::::::::::::::.:::::::::::::::::::::::::,::;:::::::::::.:....i.::::..:::. ................ .... ::..:-......•:::::•:'.:::::•:'.:.u.pl,an:„.•:*:.:::-...:•:::::. . -.'::::..::::''.•-••••:•:-:,::::::::::•::::::::::.::::::•.::::::,i::::::::::::::::::::::::•:.:::::::,::::::::." ::.:::::::::,-::::•:::::: • :: :..:::::•::•••••••••:::::::::•:,••••Aiehitecturial:draWinga,:::::::::::.:::::::::::::::::i::::::',i;:::•••M:::k•;:::•,.. Stfuctiiral.:'draWingS.'•:::::::...0:::::::::......a::,::i'..•,•.::::::Ki•..X: •:•••••:•:•!.Mecharilear drawings •• : :: erlevations i • • ' •••••• ' ' '' • ' :: ' •:::::.•:::::"•:.•:'.":• ::,". ,...":'..:'::::'. :.:::::::::::;::;:::::,:a:::::', ..., • •••••••••••-' •.• ••":'••••::. `..:C:1%1111drawings:::::::::,:::,:::,...:::::E.•:::..„...:..„:•::.::::::::::::::::::::::::,........:.y....t.:::::........„ ......„. • :::...., !.. .......::,::-...........::::::::::::::::,::.::::::.....::i::q:,,,::::::::::::::,.::•.:::•,:..:::•:,::. .„::::::.•••■•.:LandscaPe...piari.,::::.:-:::::::::;!.:::::.::.•,::::::?:::••••••:::::' • DOMPfatad.,'Utitit)%7::"POrMii'•,a.' ''' '' '''''''''''''''''''''''' .... :•FISix (6) sets :Of :civil draviii.ijS::::::::::::,•:,:.:,,....." :"••••,..",.::::::::::::•:::::: ••••-••••••• ...H.:.....:"•::::•::'.......:,•"••••••:".::...::"":: :.:NOTE:!...Eee..U.tilio;.'13,eimit,..0.pliq, '''' (.1„9et:0PY.:..a.....11. 6'......)(ii....t....::!9,..::;p001.....,.../1....o1:00 • • . • • • • . . . ". • • • • ••• • •• •• • • • • • • •• ...J... ....„........„.„..„„ „.............„....„.........-,......... • submittal .requirements::::::::::.::..:::;:.:::;:;:•::::::::::::::'::::::::.:::::::::::::::::::::::::::::::.:.:::::::,.:::::::::::::::::,..:;::::::::::::::::::.:::,..::::.::: ...: ..........„.............„......„..... ....,............i..,...........:„......,..,......,...,............ . • ..„•,.................,... ' ' • :• RACK .Completed ••• ..AssesSorAccount :Number Two (2) sets of;plans,'Whiott•incllide;::::::::::,-:,.:: ri Building floor plari • .•. ••• • • :: ' • • :•••••• • • Entire.: SpaCitr:Where• racks will be iocated :••• • • • • Exit:doors Dimensions of all aisles ,•••• Tonant space flOOr,:plan showing raC k at• O rage:lay oui„aiSiai and • • NOTE: Include dimonsions and and exit wayslon, ' •••••••:"•:•::' • : • : ••• ••••• • . • • • • .• • • . ;•. • • . • .:.. •• Structural calculatioria:•iiiMPed by a Washington •StataiiCei!e, engineer • (rack storage 8 and over) • • • • ' . ' RESIDENTIAL CoMpieted:bitildng:•perrnitapplipatfon:: onp:bei each structure i..:.NarratiVe•.deSciibirig•exiating.,ioof,::Material::being.reMoVeci;!:'Etti ofl of the permit ... . .. .......„. ..::.......:•••..,...... : • ........„.„:•:„..„...:.......,...... , • . • • :•: , . :::. .. : ' .......,....."..• ........ ••......,............- , •: • . - „ . NEW SINGLE -FAMILY• DWEL.!:.INGS/APPITIONS.:•::::::::::,...:•::": .:.,:.:..,.........i,...,..•.,....„.......;.:::::i...,..„:::,.......: . :,......:...,........................ .. 1:1pSIDENTIM.;::::RgMODELS.:::::::..:•.:::,:l.;:::;:-::.....::....:::::::;:::.::.:„ • •'.,....,.:::::::::.:::::":::.;..:...!..•:::.::::::::::,::.....i...,:,:!,:::::•;':::,:,..,:::.1....,..,:.: . . . . .. . . ........... ,. . ... . . .,..,...„.,...... ' : -:".. :. ••.....).:': .. • •• :. „ .:.:-.-.....',..:::.: -....:....,....:..,:,.,.:.:.....::'..::,.•.:.:..,,,,,.,:..:: . .:::.:.:.:.,:...„.. Completed building permit.appliCatibnlond•::for: eaCh'•:Stnicture •:-:•••• ...... Completed. blinding permit application(onel.foreaCti':strUCtiire) ,1:::.:•;.:::::::::: .. , ... . • •, .,........... .......,.....".::..,:„....,....::-...,..:.•:..........:.:„......,....,„ •.:.,::: i . •:• •: - - - •••••• ••••••• ••••••••:.•::••• •'• -:::••:.::::::::.:•:i••.::::•••.:••:::•••• :::::::::•:::::,::::.i.i..;•:...:...:•:„...ili..;:..:::: 1 1::.A6sei6OrACCiitini Ntii-nbii.,...,---..... Assessor Account 'Number :::::::::•:::•::::::::':::::.:::.::::::::::::.::::::::::::::::..;.::::....: .: . ::....::: •:•...:•••:::•::: .,.. Legal desCriPtiort.::.„.., • •:...::„..:::'1:::••••,...•,.....,:::::::,1.i::::::::..:i:......!:::..:.::::...s.;::::!:::'.::::.•..::.:.:::;:::::::::::„;:::::::::::::::,:.*::•.::::::::: ,•,:: • .: .."::•: -:•:::::::::: •••• .•:•:-.: .: ...•::-:::::::::,::::,::.:.: ...,...,....:....,:,. „...,..„.........,............. ::7WO.•(2).:.',seta.bf,;VoricingdraWirtgai::Whichin.CItide:'.:::':::::!:::1,:.:.::::::::..:-...:i.::::::•::.... ... .. • . . ... • :::—••••.:,,..:.: •-• ... •..... .. . . ......... •• • - •• plan ••••-"„ ..,...-•,...:"...:-.•:::::•.:••••;:.::::::•,'.;','::::::,::::::-:::•':..i.:-.,,,,,:..,,:::::.i::::::::,::.:::,::::,...:,:•,...,::.:i.'••-•''.•. '.•-•'"--•'•••• • Two sets.(2):Of.WOrking :drawings ;:•WhiCti:iriclude::.::.?,::::::::::::,.:::::::::::::::::::::::„::.„: ••:::••:•FoUndatiOn.:plart.::::::::::::::;.::::,::'•::-:,::".::::::.•:: :. ' : ":: •-• Site plan.,...‘ .... ''. .... • • • ••• • ttivdrant location. .:,:..;.....,. • ..• ....:ouridation p,. an. :'...:::• ..,.... :•;,, ..,,,, . Floor pian . ',...•:.:. ' ' ,.'... :/OrijAinioh°`Y:`49sc's b..`llaiia.,44*Ing.:.::g. ■ .•'. ..:'....::••:: • • •• .h..indude access • "" • :-: . •" •• .......:.••:..,..:.::::•::::::•...::::..............::::.::...:.:.•::....::,:i :..,R....!•i•:•...1.31°U9ildrnPg171e1P4tJ9'..;!§:;;;•.!:;;....'7..';':',...:...::::::::::::: oot plan.........,:::,...:; .,:::::,.::•.:::..... ,:,..",,',:::::,,:,:..::: Oou pan :.:::::::::,:width, and Ittunett.'atacoi!ss.J:::::.::::...:, ::.'..:(46110frig br°s7;9-•,t1'.;19:'•::.•:::::::::::•'!:::::':::::::::::::i!iii:J*:::::•:':':'• • ...•....,::.:.,:. • .i..Buildici • iavation • all vic,,i,i):",:•:::.:::::.::::::::',••••::::.::::.:.:::•.:::::'•::::::::..]:.:::::::::::.:,:.:::-,:„...:.-:..:::::: ......!.....Structi.iral:framing•plans......,.....:...„::% :......,..•::.:. f. Building cross -soction,::::::::'„:.:.:',:::••::•::::'::'•:•:'::'•.'',.',1..::':',:•••,':'::..',..'.:'.:•::::: •.:::NOTE.fliinyUtility:•.Workis•:•10.:.paidona.pr0Ide:.:141111tyiPerpit.;AppIlCal19lI..::::: ::::::: ..::., • Structural framing planS.'.:.•:::::::::::.:•:::::•::::',:'::••:::::::::::.:•:::::::::::::•-:::::.•:':•g -...:•:•:•:,':','::::::';:.:.'•:.•.:::::•::::: :::::and:plai?s :1771.10: bo:s•uiiiiitted.,...i:::::'::•.:::::::::::::::::•::::::.,1:-::''''''''',••••:•••‘••.*:-.--:" •,':' •::":::':::!....:::::,..::•.:.:':;:::::.:::::..1:.:.::::::i::::::::: :-.......:,....:.,..:•... ............. I J Was hingto n.. State .Eriargy,:Dode • ..:.•••••• n• . ................................................................................................................. cqmplefed9tiliP1P9r.77.... n.".77.7,...- ; • Six (6) sots . . • NOTE'. • BUIlding' site plan:and' utility: site:elarfinak....bacattlyned.:,-;:See:•;•::; . Utility p•Orrri)t.:Oppilationl•rartd..ortaok//th:Ipr09i11P-S)OiPittak:ra901/.19TP1?..:.1 • .. '...-../.tdc;iftionaltoi*?gipOhical and soils in(omation may be roquirod if unique q.ite • .. ............. • .. • • Assessor Account Number 1 1 Narrativo de0,riblhsj exisung root, matenai being removed ani • NOTE A ce f'gal(1.)...i!.':..1!?!Ori'll'ec#11(0q.,:r194(?': • : . • • • • • . ..• . • . • • ....... „ • • • " "••• •••••' • •••••••:".•:••••• '•"••• • • •: • •••• •••••••• • •••••••• •••••• ••• • ....... . .......... . .. • . . • . . / ' GENERA 117.00 ^+**a*�a.A***A**+*^++**a++^++*+lic+**4,a*^a**+**aA*a+**a*.A***a**+*+* GENERA 4,50 CiTY OF TUKNI).A, NA T8ANDMIT TOTAL 121.50 ***+*+++*+^^*x*h++*++**aa**A+++**+*+++a*4*+$F***+ai+*f+A*11+**a*+* CHEI% 121.50 TRANSMIT Number: 94001806 Amount: 121.50 02/08/95 15:34 CHANCE 0,00 Payment Method: CHECK Notation: DAVIS SCHUELLER inttA0BM5D 9943A000 15:46 Permit No: B94-0440 Type: B-BUILD BUILDING PERMIT Parcel No: 359700~0006 Site Address: 14900 INTERURBAN AV G Total Foes: 197.5b This Payment 131.50 TOtol ALL Pmts: 197.55 Balance: .00 +^*a+***++**+++++*aa*a*++A****+^***A******+*a**i++oA***+*0***** Account Code Description 000/322.100 BUILDING - NONREG 000/386.904 STATE BU%LPINR SURCHARGE. Amount 117.00 4°50 1 t 4h**: 4•.4* A** 4** A;***.% kAk*4t* 4*' 4* **4*4 **k' ** *A *k•k:4'e44*4***4* CITY OF •1•UI(W1L.A, WA * * * *4*4k A 4*44 4*. 4** h* **4*4**A•k•k*k***44***4*k**44k' 4A44 A*A TRANSMIT Number: 94001 675 Amount: 76.05 12/30/ Permit No; 094• -0440 Type. 0• -BUILD BUILDING PER Purce1 No: 359700 -0006 Site Address: 14900 INTERURBAN AV 3' Payment Method: CHECK Notation: IN PLAIN AIR ARC In 4 4'4444* A**4• k• k** 4**• 4*4c****• h** **4*A*AA *k•kAk4* **k* *'** * **'4.4 Account Code 000/345.330 A * •k ,4 h• .h k h TRANSMIT 44:A *:4*A* 94 15:09 11.x'730/94 it SAO *******4 Description Paid PLAN CHECK -- NONREC3 76.05 Total (This Payment): 76.05 Total Feos: Total All Payments: Balance: 1955 76.05 121.50 GENERA TOTAL CHECK CHANGE O570A000 76.05 76.05 76.05 0.00 15 :15 f �f:. •.. �:rJ �... - ...... ..r % -....f ��- ..t�. F.b. ... u.. ..�....r1 -. ...�...., ..i.... INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 ro ect: 71 i .474 zei, Type of Inspedt n: , �� /� Address: J Date Called: **.. Spedarl nstt�tions: C- P / 0:141 /( / `�' s `" 1 ` :r'!r , Date Wante�� m. Requester. Phone No.: II...Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ❑ $30.00 REINSPECTION FEE R QUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. _{ �'. F;a,.Y 3 - INSPECTION RECORD Retain a copy with permit I SCI P TON N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 re ect: Type of Inspecti6r; f (_- /N6 4(J7) II f G Qate Called: 1/47.5 aI Instructions: /e c• 6j Date Wanted: ,,,.., � 954 Requester: . ;ft �•� l Phone No.: 57 A _ ' a v' XApproved per applicable codes. ■ Corrections required prior to approval. COMMENTS: ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. L It4SPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Project,/ 0 ;.&...0._ z c...... , ype o ns • .. • : c fLe--4,b L ti- .DF-. u,SW— i S. fLers Stlg-voi‹.— (.249 3 (1.41-D4(1.1 ' or ALL ‘JALLS. Address: j 1 (x) mitt iv? -a pate Called: f. ,,,i, 05- Special Instruct ons: /Pt Date Wanted: / ify) / am. Requester: --,...i-_:.1, j(( Phone No.: 0 Approved per applicable codes. -Corrections required prior to approval. COMMENTS: l..-1b61 : 9 Te-vCcS kk-otxmita-9 1 IA %,c,-,Isy,,, c_ eovs. ) ,.,--.1t-- L,-e 2-.‘ 4. c fLe--4,b L ti- .DF-. u,SW— i S. fLers Stlg-voi‹.— (.249 3 (1.41-D4(1.1 ' or ALL ‘JALLS. CA— A") (-4 v-cil— (L)-rvio 1-.;$2 .4-(1—. O/ SNA-C•C • o moo REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectlon. '4),,,:m4mwakow*.*4..A4e.—..046.41.111Igkette. C INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0-7 4,1 +09.70 PERMIT No. (206) 431-3670 Pro7-1:5 cy,‘,. ..../ 01.,_/.64. : c.,. / y e o ns . on A P Pe Cae 7L) c14' Addreki _Ade Date Called: Special Instructions: Date Wanted: 3 /.75____,„:„ Requester: Phone No.: (54 C. 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 143g4",1-4-&-e." _Ade 1-7 12 0.e..4.1 Se- viZ7 .-",1 ti-E5 (54 C. .. C$1.-7 1.4/ 'etIO C..■ es- C-G4401-- 1 C7fr,--/44 Lspector: Date: o $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. e.t.tra•ka er22t,sr“...n. _ . INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 ro ect: - yype of Inspects Address: 67/67,, „ j/C %,(,, v.zot;:de Called: I Special Instructions: j � -U Date Wanted: �. . / _. ..- ) / /' - (l`::;) am. ; Requester: - f Phone No.: ,z / ' _,.. zoi Approved per applicable codes. COMMENTS: / �,7 /4—/is ❑ Corrections required prior to approval. A/0 L —e �•^ e'4. kti 'l ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Recept No.: Date: 1 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 ro�P tech �, ype o nsped on: / Address: /,� /1i � bate�alled: ) Spedal IIn�s��trruyctions: /.''tt�h6 %GLiL Date Wanted: s� c J f %U I a. 4.m. Phone No.: 1.o ate? Approved per applicable codes. D Corrections required prior to approval. i 0 $30.00 REINSPECTION FEE R • UIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. receipt No.: IDate: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 ro ect: �GtiN.ce7 '= 1 i 191u,rnt JJG Q.euCNit - t J (LeGAN ‘7.417 . (A-1v. 1ti G .--, of lnspection:� --; �� v1 _...... z - - P,lay. oE' Are APP'- ovr-9 Ai.--TA 1 L- TO 'OW. c cri Address: Inc 1tiler . i i C) : e Galled: , v,Jc �,�,_ I4 L \ A•-a vow rYAECiA. S tkf4( -; AL..1.4 S caa,u t,a Av- Special Instruct ons �.. Date Wanted: Requester;:"51 i ( Phone No.: 9 `--C C.. j ❑ Approved per applicable codes. (Corrections required prior to approval. COMMENTS: ' 1 i 191u,rnt JJG Q.euCNit - t J (LeGAN ‘7.417 . (A-1v. 1ti G / 11PQIkiVlm.. t S St,•ws-C- -it N .S0€S"`011 - AP (',W✓AL- _...... z - - P,lay. oE' Are APP'- ovr-9 Ai.--TA 1 L- TO 'OW. c cri tAhk∎Cki De-C-1%-o. (A. —OW I NA. wP.?el 4 c1"rao) vj -.L M1 Avaw (Ay/ Th S iv..0 c 1 4 NL' AP f it.w%cp , I4 L \ A•-a vow rYAECiA. S tkf4( -; AL..1.4 S caa,u t,a Av- 1 ❑ $30.00 RE)NSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. t JelaWlate O INSPECTION RECORD C' Retain a copy with permit INSPECTION14O . CITY OF TUKWILA BUILDING DIVISION rill: 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO./ (206) 431-3670 project: /..744,11 (/0 . i i ype ot Inspection 762_ dress:/ i p Special Instructions: ..p..„ D Requester: ...___....41/ Phone No.: .... 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ' :IA7— - i tJ A •%A ..,-;_ L. , r i - 3) C-ba-a-tzw-a14— A-Arse) 1.44N-1-43 S g:rv) 0 rJ PLeSr.15 Ad C vx-r1 v., th, ar. (), e )'‘) 7-4 F 0-■lx)i. .0,--1.-- n .4-1,x4z__ ,k-f\ 0,-c4JA-Inc- A 1 /4 It-- ILA 11 t-)6). 1-14 AT-7- A il-A-T"Er, ACttxril CA L TI.L-C S*-.)-"A'N I.S A (if kovir-P .. ntO 1D-r-T-A(4-- C--‘-‘1.STI Anil) /V-U– CA /4i,14 122:0:4-sa t rt-Er C-0-1 A t emvm.... 3 (AI A-1 ,..- .Lit.,A c..E:t it_1FG-u 1 4f Prrrti"\--.-1.1 eL.A-gt to wort...0 A,— z_.' 0. C . IInspector: C 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. IReceipt No.: Dale: L. *a .4.•.0..r1V41471:1141:31....1" 4- • cary, of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name o 1,t711 e +t?°.� f/&-pa Address John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. ii/Y-OC/VC)1 Retain current inspection schedule X Needs shift inspection Approved without correction notice Approved with correction notice issued Suite # Sprinklers: .. Fire Alarm: Al Hood & Duct: )00 Halon: lam) Monitor: Pre -Fire: Permits: 4/"„\0,660/410-56,) Authorized Signature FINALAPP.FRM /cg— Date / T.F.D. Form F.P. 85. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575.4439 CITY OF TUKWILA Address: 14900 INTERURBAN AV S Suite: 275 Tenant: SOUTHCENTER PLAZA Status: ISSUED Type: B. -BUILD Applied: 12/30/1994 Parcel #: 359700 -0006 Issued: 02/08/1995 Ar4 *.•k•k'k** k k• k*- k• k•k•k•k•k•k-k•k•k•k•k-k•k•k•k•k k• k• k*• k• k*' k•k•k'k•k *** k k•k'k•k•k•k*•k k'k kk**•k•k•k•k*•k ' k•k•k k*•k k•k•k 7r Permit Conditions: 1. No changes will be made -4. ' theplans unless,;..approved by the Architect or Engineer° Sande =the Tukwila "BOOd.ing;Division. 2. Plumbing permits.,..aha.l °1'r be obt;ai:ned through theV,.Seattie -King County Departmefht' of Pub 1'i;c`, Hea 1 th ', _ P 1 umbel ng w 1°1:1., be 'inspected byy. that agency,' -'1,ncl ud ing al) ga ,'p i.p i ng (296 -4722) ��'Yi !' ;fj !3 ` J " 3. E l ectr i ca,.(,4ierm, is ',sha l 1 be - ob't`a i ned` `'through the �?'Wash i ng;ton State Division ' " - of Labors and Industries e1ctricai work wi i ;be i nspecte by (248-6630).; tha'.t `agen,cy 4. All meci•ra'nical work.•�°shall be under parate permit issued the C :l tyr of Tukwila. t, 5. All p'o'rriits:;;. inspctio4n records,. and approved plan s si all ava 1.1 ab l e at`' the' .job site prior `'to the start of any. cdn -.: structlon. These documents ar:'e to - be'maintained and avail able :. until final insp'eetion approv ,.'.,j's'�gr;anted. 6. Any; n;ew ceiling grid and{ light ,fi.t.u,r�e instarllation is requ'lr-ed td) meet' lateral `bra'cing tr'equir�`ements for Seismi Zone A3. 1, 7. Part,1{tion,:walls `attached to ceilirjg•. grid' must be laterally rF braced 'if,':over eight C �),' feat in le,ngth 8. An ':ek ose.... i s 1 , sh ; y�, Q�,; r u afi�an,,•� :,,track: ing '- ;mataria�i °�`•�ha'li have a FtiTam�: Sprea4 Rating of 25 or less, and'{rnateria lr-- shatl bearb id e.nt•i `- f i ca.t;ion.-showi n'g the fire perfornnance' �rating, thereof'. 9. All cbnstrt�uct`jon�� to be done in cono;rrrance..• wi tI' approv,e,d' �•`` plans aFndt;r,,ecjuirements of the Uniform B "uSiliiing'4Code (19714 Ed i t i d�rr); as amended,,: Uniform. Mechan r "cal ode (�1:9 '1 Edition and Waaf1'�•iington ;,Stater Energy Code (1994 Edi,viori) :• 10. Validity y0f Per�mi t . The issuance of a perms t or a prova l,,�. q. plans, spe;;c i.f i cajtti'unr and; om a tat i ons h , ': "e' co ' -. strued to`'be`'�a perm'it for, ur�`-'an,appr*oVta�l of any violat;Son of any of th'e:. pr,rov i s i ons of the bu i 1 di;ng code or of.°.ai?y other ordinance ofd the .jurisdtction'.. �3 No permit pr divning to give authority to,violate or canciel'4the provis,;i o :n!; o`t this code shall be vali` Permit No: 894 -0440 City t of Tukwila ila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 John W. Rants, Mayor January 17, 1995 Fire Department Review Control #B94 -0440 (510) Re: Southcenter Plaza - 14900 Interurban Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1-6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.505A) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly *ILA r City'l'of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3303(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 12.106(c)) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Internally illuminated exit signs shall have both bulbs working at all times. (UBC 3314(c)) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 3 John W. Rants, Mayor work shall commence without approved drawings. (City Ordinance #1646) 4. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1646) (UFC 10.503) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 6. Walls of corridors serving an occupant load of 30 or more shall be of not less than one -hour fire resistive construction and the ceilings shall not be less than that required for a one -hour fire resistive floor or roof system. (UBC 3305(g)) Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.601) When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of U.B.C. 4203. Fire doors, fire windows and fire dampers shall have a label or other identification showing the fire City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 4 John W. Rants, Mayor protection rating. Such label shall be approved and shall be permanently affixed. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd CITY OF TUKWILA Id: ACTPIZ`. Keyword: UACT User:77 01/13/95 Activity Table Processing BUILDING PERMIT Permit No: B94 -0440 Tenant: SOUTHCENTER PLAZA Status: PENDING Address: 14900 INTERURBAN AV S Type: B -BUILD Vers: 9101 Screen: 01 Base Information Parcel No: 359700 -0006 Owner: SOUTHCENTER PLAZA Validated By: SAO Plan Ck Approved: / / Status: PENDING Applied: 12/30/1994 Issued: / / Active /Inactive: A Completed: / / To Expire: / / C of 0 Issued: / / Bus Lic #: Final Notice: / / Nature of Work: EXTEND CORRIDOR, ADD DEMISING WALLS AND DOORS TO Location: Category: ACOM (N= NEW /A= ADD /ALT + SFR,DUP,TRI,APT,MH,COM,IND) Zoning: C2 Gas /Elec: Census Code: 437 # of Units: 1 # of Bldgs: 1 Pub Own:N Streams: Slope: Y Wetlands: Water:N /A Sewer:N /A Setbacks - North: .0 South: .0 East: .0 West: .0 Valuation: 10,000.00 Fire Protect:SPRINKLERED Type Const: V -N Type Occ:0016 OFFICE UBC Edition: 1991 Occupant Load:47 Occupancy Grp:B -2 F7= Update, F2= Previous Line, F1= Screen Index, ESC = Cancel Update CITY OF TUKWILA Id: ROUT130 Keyword: UACT User: 1677 01/13/95 Activity document routing maintenance. BUILDING PERMIT Permit No: B94 -0440 Tenant: SOUTHCENTER PLAZA Status: PENDING Address: 14900 INTERURBAN AV S Route: 1 Current Route Line: 3 of 6 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Packet Units Action Station Initials Status Received Assigned Completed BUILD 01 01 C BLDG KEN Approved 01/05/95 01/13/95 01/13/95 Priority (0 /low..9 /high): 0 Regular hours (HH.MM): .00 Overtime Hours(HH.MM): Comments 1[OCC. LOAD 47 ] 2[TWO EXIT REQIREMENT IS SLIT BY USING 1 -HR CONSTRUCTION FOR ] 3[RECEPTION ROOM, SEE UBC 3303(E). ] 4[ ] 5[FIRE PLEASE REVIEW AND COMMENT. ] 6[ ] 7[ BY KEN ] 8[ ] 9[ ] 10( ] aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa F1 =Help, ESC =Exit current screen. 01 -24 -1995 02 :48PM FROM DJ SI 1 DI TO 4313665 P.02 REGISTRATIONS AND LICENSES STATE OF WASHINGTON UNIFIED BUSINESS ID 0: 801 273 797 BUSINESS ID 0: 001 ' is EXPIRES s 01 -31 -1995 ORGANIZATION TYPE DOMESTIC PROFIT CORPORATION DAVIS SCHUELLER INC. TWO UNION SOUARE G00 UNIVERSITY ST (5500 SEATTLE WA 98101 DOMESTIC PROFIT CORPORATION RENEWED BY AUTHORITY OF SECRETARY OF STATE The above entity hes been Issued the business registrations or licenses listed OE!W TMENT OF LICENSING•!USW[SS 6 PROFESSIONS 01VISIQN, P.O. eoz 8034 OLYMPIA WA 96.907.9034 (206) 75344101 • 1900011160 ll jl / JI nfl SI ..\\...\.<. w\,• a\ r..\. \,,:.vl\\\l.\ua\w1�•wt \\\\\\\\\ MMA...\\\ ,'"•v\\•\\\\\\\\ \\y\\..\a\\t\ \\\\ Mh\\\\\\ v�\\\\\\\\\\\ ti\\\\ t\\\\\\\•,\titiw\\waea\\\��a1 +.1: t & i.T PM • AtbI• l V11 1,w11.HU0n11A♦ Y•O/11bbVV •∎O YIIVb •01 WWI II • lry • r$ vr•r'• TOLL FREE 900.062.8205 2061758 -4401 TOTAL P.02 0 1 W i1 INTERIIRBA N SITE PLAN 1_ +/- 1" = 100' �I i 1 icz4 cal icc tz; (:.!, •ONsM�`0 p0�p pN• �S eE vZ vas f p t CORK ..00:0G avescipa. P FsES. 10 S � oovoNAaC \0y N PLAN NORTH ro�a�s are IMO heck app ro�a1 °{ that the P1a; Chec ap r n of ae �,��t fiend ots and om the 401 atio of con - ,�.;�'�esttoesr tots authorize Receipt ack °�'`Nladged. Psans does code °t approved adopts copy °� ap �1��7,1�*'`r \tactot'9 / ..-- 6V pate P 1 0 TENANT IMPROVEMENT LEGEND IG DC SW s SDS 1M s3 DUPLEX WALL OUTLET • SPECIAL DUPLEX OUTLET • FOURPLEX WALL OUTLET • SPECIAL FOURPI.EX WALL OUTLET • DUPLEX FLOOR OUTLET, FLUSH MOUNTED WITH COVER • DUPLEX FLOOR OUTLET, PEDESTAL MOUNT • COMPUTER OUTLET - JBOX AND PULL WIRE ONLY • PHONE OUTLET - JBOX AND PULL WIRE ONLY • ELECTRICAL BOX, WIRED FOR USE NOTED • THERMOSTAT • ISOLATED GROUND • DEDICATED CIRCUIT - SIZED FOR USE OR EQUIIP. NOTED SPILT WIRED (OUTLET) • ELECTRICAL SWITCH • DUAL SWITCHING • DIMMER • 3 -WAY (SWITCH) • 24 ADJACENT TO ANY FIXTURE DENOTES 24 HOUR OPERATION • L J 24 2 X 4 FLUORESCENT TROFFER - 4 LAMP, 160 WATT _ 3� j r 8' SUSPENDED FLUORESCENT - 1 LAMP, 80 WATT 4' SUSPENDED FLUORESCENT - 1 LAMP, 40 WATT UNDER CABINET FLUORESCENT TASK LIGHTING • ANGLED UNE DENOTES EXISTING FIXTURE, EXISTING LOCATION • ANGLED SHADING DENOTES NEW OR RELOCATED FIXTURE • INCANDESCENT DOWNUGHT - 75 WATT • FLUORESCENT DOWNUGT - 2 LAMP, 26 WATT • INCANDESCENT WALL WASHER - 75 WATT • FLUORESCENT WALL WASHER - 2 LAMP, 26 WATT • PENDANT FIXTURE - SEE NOTES ON PLANS • LIGHT TRACK • �- TRACK UGHTING FIXTURE - 75 WATT • EMERGENCY PATHWAY LIGHTING 2 X 4 FLUORESCENT TROFFER - 3 LAMP, 120 WATT 1 X 4 FLUORESCENT TROFFER - 2 LAMP, 80 WATT • 2 X 2 FLUORESCENT TROFFER - 2 LAMP, 80 WATT MEMOS 0 4 1;' O B • • • EXISTING SPRINKLER HEAD • NEW SPRINKLER HEAD • REMOVE OR RELOCATE SPRINKLER HEAD • FIRE ALARM HORN • SMOKE /FIRE DETECTOR • FAN, 200 CFM UNLESS OTHERWISE NOTED • • EXISTING WALLS TO REMAIN • DEMO EXISTING WALLS (NOT ALL DEMO SHOWN - VERIFY ON SITE) • NEW WALLS • NON -RATED PARTITION TO SUSPENDED CEIUNG. 5/8' TYPE X GWR EACH SIDE OF 2 -1/2 INCH METAL STUDS. LARGER STUDS IF NOTED. • 1 -HR RATED FULL HEIGHT PAR IMON WALL we TYPE X GYM EACH SIDE OF 2 -1/2 INCH METAL STUDS. DMID WALL TO RATED FLOOR ASSEMBLY ABOVE, • EXISTING WALL SYSTEM. PATCH AND REPAIR AND APPROVED BY BUILDING OFFICIAL AS ALLOWED CODE & ZONING • MANAGEMENT: SUHRCO MANAGEMENT INC, 10655 NORTHEAST 4TH STREET SUITE 710 206- 455 -1950 BELLEVUE WASHINGTON 98104 FRANKUN TSENG • • ARCHITECT: IN PLAIN AIR ARCHITECTS & PLANNERS DAVID SCHRAER 4031 - 41ST AVENUE SOUTH 206- 723 -1927 SEATTLE WASHINGTON 98118 • GENERAL CONTRACTOR: DAVIS SCHUELLER INC. 15620 HIGHWAY 99 SUITE 16 LYNNWOOD WASHINGTON 98037 UC. # DAVISSI105PN • PROPERTY INFORMATION ADDRESS: SOUTHCENTER PLAZA 14900 INTERURBAN AVENUE SOUTH TUKWILLA WASHINGTON 98168 PROPERTY TAX NUMBER: LEGAL DESCRIPTION: THAT PORTION OF TRACT 1, INTERURBAN ADDITION TO SEATTLE, ACCORDING TO THE PLAT RECORDED IN VOLUME 10 OF PLATS, PAGE 55, RECORDS OF KING COUNTY, WASHINGTON, LYING SOUTHERLY OF A UNE WHICH EXTENDS NORTHWESTERLY, PERPENDICULAR WITH THE WESTERLY UNE OF SAID TRACT, FROM A POINT ON SAID WESTERLY LINE WHICH IS 685 FEET SOUTHEASTERLY FROM THE NORTHWEST CORNER OF SAID TRACT; AND LYING NORTHERLY OF A LINE WHICH EXTENDS NORTHEASTERLY, PERPENDICULAR WITH THE WESTERLY UNE OF SAID TRACT, FROM A POINT ON SAID WESTERLY UNE WHICH 15 1,555 FEET SOUTHEASTERLY FROM THE NORTHWEST CORNER OF SAID TRACT; ALSO THAT PORTION OF THE VACATED PUGET SOUND ELECTRIC RAILWAY R/W ADJOINIING THERETO LYING SOUTHEASTERLY OF SOUTH 149TH STREET AS COVEYED BY PUGET SOUND POWER AND UGHT COMPANY TO THE CITY OF TUKWILIA BY DEED DATED OCTOBER 251H, 1965 AND FILED UNDER AUDITORS FILE N0. 6557639, AND LYING NORTHWESTERLY OF A UNE WHICH EXTENDS SOUTHWESTERLY PERPENDICULAR WITH THE EASTERLY DINE OF P.S.E. R/W WHICH IS ALSO THE WESTERNLY LINE OF' AID TRACT 1, INTERURBAN ADDITION, FROM A POINT ON SAID WESTERLY UNE WHICH IS 1,555 FEET SOUTHEASTERLY FROM THE NORTHWEST CORNER OF SAID TRACT. BILL DAVIS KEN SCHUELLER 206- 787 -1059 37- 0533090 ZONING: BUILDING AREA: EXISTING PARKING: CONSTRUCTION: STORIES: THIS TENANT IMPROVEMENT: OCCUPANCY: B2 OFFICE M1 - UGHT INDUSTRIAL/OFFICE +/- 56.834 SQ. FT. +/- 233 SPACES VN (ASSUMED) - SPRINKLERED TWO i� ca O It-44 gift cc (9, 0 zo � i OCCUPANT LOADS: SEE DIAGRAM A ONE HOUR CORRIDOR HAS BEEN EXTENDED TO CREATE TWO SEPARATE CCCUPANCIES FORA SINGLE TENANT. THE EAST AREA OF OCCUPANCY HAS AN AREA OF 2.051 SQ. FT. AND A MAX. OCCUPANT LOAD OF 12 WITH TWO EXITS TO THE CORRIDOR EXTENSION. THE SECOND AREA OF OCCUPANCY HAS AN AREA OF 1.992 SQ. FT. AND A MAX OCCUPANT LOAD OF 13 /OFFICE AND 25 /CONFERENCE ROOM WITH FOR A TOTAL OCCUPANT LOAD OF 48 WITH TWO EXITS TO THE CORRIDOR EXTENSION. INCLUDING A AN OCCUPANT LOAD OF 5 FOR THE RECEPTION AREA, THE TOTAL OCCUPANT LOAD TO THE CORRIDOR EXTENSION 15 12 + 13 + 25 + 5 = 55 TOTAL OCCUPANTS. 2051 SQ. FT. 482 SQ. FT. 1992 SQ. FT. (OF WHICH 371 SSQQ. FT. IS ROO A CONE. M) 1 j 11sot t_t. Z It it. ='tt TOTAL OF 4.525 SQ. FT. rr�t` :(71f<-si;,•)L` — CoC ;Rtt.1* SNI3/4 ‘133 w RECEIVED CITY OF TUKWILA DEC 3 0 1994 PERMIT CENTER ENERGY CODE THERE WILL BE NO INCREASE IN FIXTURE COUNT, FEWER THAN 4011 OF FPRURES WILL BE RELOCATED. 1U pfl�d sl SUITE 275 SECOND FLOOR PLAN 13 04110 RECEIVED CITY OF TUKWILA DEC 3 0 1994 PERMIT CENTER L 14' -r XXC19' -o' 10' -e9 OFFICE 11' -r OFFICE 9' -2' X 17' -4' OFFICE 9' -• X 15' -7' 10' -°�X 11' -a' I OFFICE 1o• -s x 11' -011 OFFICE 7' -10' X 11 OFFICE 9' -6' X 11'-O' OFFICE 14' -1' X 14 -9r SP 10'•49 OFFICE 1' -8r —a— \se.... OFFICE 8' -11 X 17' -1 OFFICE 10'-r X 11' -9' OFFICE 11' -7' x 14•-B• MAIL ROOM 9' -1' X 13' -ar BREAK ROOM 14' -8' X 21' -5' MOO OP= ilm• BOOKKEEPING 10' -er x 16•tl' J RECEPTION 13' -11' X 18' -5' OFFICE 10' -47 x RECEPTIONIST 12' -2' X 17' -2• L J L�J MICRO N.I.C. SINK DISHWASHER REFRIGERATOR OFFICE 14' -11' X 20' -? OFFICE 10' -r X 11' -4' OFFICE T-11 X 16' -3' PLAN - PARTIAL 2ND FLOOR SUITE 275 4,525 SQ. FT. RENTABLE AREA 5,050 SQ. Ft RENTABLE AREA drmamlib 13c14-014-10 1/8" = 1' -0" PLAN NORTH co-- Z —cc S1 C%2 RECEIVED CRY OF TUKWILA DEC 3 0 1994 PERMIT CENTER \CIIIR PUN It a 4'— f ALL SYSTEM XISTING /- 1!' -0' ' 4' -4' +/- 10' -8' TYPICAL - WALL SYS1 NG Noso•NImicE2C r C IL +/- 18' -r ONCE HOUR CORRIDOR ION \o/f WI 1 4' -4• I 10' -e' +/- 12' -2' • 1 • AUGN w _ fi GWB COLUMN SURROUND - MIN. SQUARE SIZE MAINTAIN 1 HOUR RSARATING TI OF HVAC MICRO N.I.C. DOUBLE SINK DISHWASHER REFRIGERATOR N.I.C. RECLAIM VOID SPACE IF POSSIBLE AT TWO LOCATIONS WITH DASHED UNES SKYLIGHT ONE HOUR CORRIDOR NOTE: NEW UNRATED WALLS MAY BE CONSTRUCTED OF UNRATED WALL SYSTEM OR UNRATED ��GWB( PARTITION WALLS CONFIRM 0 ER'S P FREFERENCE BEFORE BIDDING. PLAN - PARTIAL 2ND FLOOR DOOR AND RELITE SCHEDULE ALL UNMARKED DOORS AND RECITES ARE EXISTING OR RELOCATED UNRATED UNITS. 1-0' WDE BY HEIGHT TO MATCH EXISTING DOORS. TWENTY MINUTE RATED WOOD DOORS AND FRAMES. PROVIDE DOOR CLOSER, BARRER FREE LATCHING HARDWARE, AND HEAVY DUTY STOP. MATCH DXISTNG WOOD DOOR FINISHES. I. • MINUTE HOLD -OPEN TIED TORE ALARM SYSTEM, D FRAME. CLOSER, AND BARRIER FREE ATCHINGRHARDWARE. PAINT TO MATCH WALLS. 4' -O' WIDE BY 3' -0. HIGH 3/4 HOUR RATED RELATE WITH SILL AT 3' -g'. LAMINATED GLASS AND STEEL FRAME UNIT RATED AT 3/4 HOUR. PAINT FRAME TO MATCH WALLS. litte edit 1/8" = 11_0" PLAN NORTH ' o - Z --- e CITY OF OF DEC 3 0 1994 PERMIT CENTER Ix C•2 A 01111-1,MM C1: fi de' PROVIDE NEW SWITCHING AT ENLARGED EXTERIOR OFFICES Mb 1 __ 1 PROVIDE NEW CEIUNG GRID AS REQUIRED IN RECEPTION AND RECEPTIONIST AREAS NOTE - GRID INTERUPTED BY NEW 1 -HR WADS 1 1 611 Cm corm ibar FrAgempon ir la intain 111 Infirm rnlaardiik • 1 i NOTES: • 1. MAINTAIN SEPARATE SWITCHING AT EXTERIOR OFFICES. 2. POVIDE SEPARATE SWITCHING FOR ALL NEW ROOMS. 3. PROVIDE DIMMER FOR RELOCATED INCANDESCENT DOWNUGHTS IN CONFERENCE ROOM. 4. PROVIDE ILLUMINATED EXIT UGHT AT SUITE ENTRY DOOR BETWEEN TWO AREAS OF' ONE HOUR CORRIDOR. S. PROVIDE NEW GRID AS REQUIRED IN RECEPTION AREA, • GENERAL NOTES: A. SPRINKLER DESIGN AND PERMIT BY OTHERS. SPRINKLERS LOCATIONS SHOWN ARE EXISTING OR SUGGESTIONS ONLY. B. FIRE PROTECTION DESIGN AND PERMIT BY OTHERS. ALARM DEVICES SHOWN ARE SUGGESTIONS ONLY. C. MUZAK SYSTEM DESIGN BY OTHERS. LOCATION OF SPEAKERS SHOWN ARE SUGGESTIONS ONLY. Etneoqqo _.••■• Stook - --- -- --- REFLECTED CEILING • PLAN — PARTIAL 2ND FLOOR MEMO, 1/8" = 1'--O" PLAN NORTH mcp•--- CITY OFETUKDWILA DEC 3 0 1994 PERMIT CENTER .t. 8 r\la r4_ WS a� cks Her2;los lzh0: d' y IO ids - A 4 ICU e MICRO NJ.C. NEW LOWER CABINET DOUBLE SINK DISHWASHER REFRIGERATOR N.I.C. Vs-'-Cs �X t enA4. o' N ar N NEW QuT"t -e.-1— p,qqeqq0 PLAN - PARTIAL 2ND FLOOR 1/8" = 11-0" PLAN NORTH co— Z --�� X t1/49 &_s 1%., , RECEIVED CITY OF TUKWILA DEC 3 0 1994 PERMIT CENTER C/1 r4 1 n 21 r I. r E._..I� w c.) H CD 0) o Dr) 7-i" \\.11111: RD tlyi sza: ter L 4. , • etigeoqqo CONCRETE SLAB OR STRUCTURAL DECK • • • • POWER FASTENERS TO RESIST 5 POUNDS PER SQUARE FOOT LATERAL LOAD. SEE NOTES ON CONNECTIONS TO POST TENSIONED SLABS. AT TOP FLOOR DO NOT DISTURB ROOF MEMBRANE. • 5 /8' GWB EACH SIDE OF 3 -1/2' STEEL STUD WALL PROVIDE SOUND BAIT INSULATION AT ALL CORRIDOR AND DEMISING WALLS. 45 DEGREE ANGLE SUPPORTS WHERE REQUIRED BY BUILDING OFFICIALS • ACT GRID AND CEILING 1I11 Ili will lilt 1r1i1111111i1�Ll;1, N\-- - SUPPORTING ANGLE AT ALL ONE HOUR WALL AT CONCRETE SLAB 3' = 1' -O' CONCRETE SLAB OR STRUCTURAL DECK • • • • POWER FASTENERS TO RESIST 5 POUNDS PER SQUARE FOOT LATERAL LOAD. SEE NOTES ON CONNECTIONS TO POST TENSIONED SLABS. DO NOT DISTRURB ROOM MEMBRANE WHERE PRESENT. • (2) 5/8' GWB EACH SIDE OF 3 -1/? STEEL STUD WALL PROVIDE SOUND BATT INSULATION AT ALL CORRIDOR AND DEMISING WALLS. 45 DEGREE ANGLE SUPPORTS WHERE REQUIRED BY BUILDING OFFICIALS ACT GRID AND CEUNG TILE 4• 4• q 4• •. 4• 4• SUPPORTING ANGLE AT ALL TWO HOUR WALL AT CONCRETE SLAB / / / / / / / /l�'i /", fll_l h. '• 1 5' • • , • • • • , • CONCRETE SLAB we GWB EACH SIDE OF' 2 -1/2' STEEL D WALL. PROVIDE SOUND BAIT INSULATION AT ALL CORRIDOR AND DEMISING WALLS. 45 DEGREE ANGLE SUPPORTS WHERE REQUIRED BY BUILDING OFFICIALS. MIN. EVERY 8 FT. AT FREESTANDING WALLS WITH NO INTERSECTIONS. ACT GRID AND CEILING 11LE 45 DEGREE MAXIMUM ANGLE FROM PURE OF CEIUNG • SUPPORTING ANGLE AT ALL PARTITION THROUGH ACT CEILING 3' 1' -0' VERTICAL STRUT OR 1/2' ROUND CONDUIT --A---VERTICAL HANGER CONCRETE SLAB OR STRUCTURAL DECK • • • POWER FASTENERS TO RESIST 5 POUNDS PER SQUARE FOOT LATERAL LOAD. SEE NOTES ON CONNECTIONS TO POST TENSIONED SLABS. DO NOT DISTURB ROOF MEMBRANE WHERE PRESENT. 18' GWB EACH SIDE OF (2) 2 -1/2' STEEL DS SEPERATED BY FIVE INCHES. 45 DEGREE ANGLE SUPPORTS WHERE REQUIRED BY BUILDING OFFICIALS ACT GRID AND CEILING TILE • PLUMBING WALL AT TOILET ROOM 3' = 1'-O' Id 11 I Id I�d4i ACCOUSTIC CEIUNG TILE INSTALLATION NOTES: 1. VERTICAL STRUTS - 1/2' ROUND CONDUIT OR STRUT - FASTEN TO MAIN RUNNER AND SECURE TO STRUCTURE ABOVE • LATERAL SUPPORTS - SPLAY BRACING IN FOUR DIRECTIONS MAIN RUNNER AT 4' -0' ON CENTER CROSS RUNNER AT 4' -0' ON CENTER • ACCOUSTIC CEIUNG TILE • 2. VERTICAL HANGERS: 140. 12 GUAGE WIRE AT 4' -0" ON CENTER SUPPORTING MAIN RUNNER. PROVIDE VERTICAL STRUTS WHERE REQUIRED BY BUILDING OFFICIAL • 3. LATERAL SUPPORTS: N0. 12 GUAGE WIRE LATERAL SUPPORTS SECURED WITHIN 2' OF CROSS RUNNER - MAIN RUNNER INTERSECTION SPLAYED 90 DEGREES FROM EACH OTHER AT A MAXIMUM 45 DEGREE ANGLE FROM CEIUNG PLANE. SPACE AT 12' -O' IN EACH DIRECTION BEGINNING 8' FROM LATERALLY SUPPORTING FULL HEIGHT WALLS. 4. PROVIDE SUPPORTING ANGLE AT ALL WALLS. • 5. PROVIDE 2 SLACK NO. 12 GUAGE WIRE SUPPORTS FOR ALL CEIUNG TROFFERS AND ALL OTHER CEIUNG SUPPORTED FIXTURES, TRIM, OR EQUIPMENT EXCEEDING 20 POUNDS SUPPORTED BY COILING GRID. • 6. ALL SUSPENDED COUNGS TO BE INSTALLED IN ACCORDANCE WITH U.B.C. STANDARD 47 -18 AS ADOPTED BY LOCAL JURISDICTION OR SUPERCEDING LOCAL CODE. 7. PROVIDE DRAFT STOPS ABOVE WALLS WHERE REQUIRED BY BUILDING OFFICIAL ACCOUSTIC CEILING TILE INTERMEDIATE SUPPORT NO SCALE `-- EXISTING CONCRETE SLAB OR STRUCTURAL DECK RUNN A reall (3) POWDER ACTUATED FASTENERS 16 GA X 12' LONG FOLDED METAL ANGLE #8 SHEET METAL SCREWS -(2) AT EACH END 2 5/8' METAL STUD 0 4' -0' O.C. UNDER 6' -0' IN LENGTH, 3 5 /S' METAL STUD 0 4' -0' O.C. OVER 6'-d' tt:s METAL GWB ON ONE OR BOTH SIDES OF < ,. vkss S1UD PARRIION OR SOFFIT FASTEN STUD DIRECTLY TO EXISTING CORE WALL OR COLUMN WITH APPROPRIATE FASTENER FOR MATERIAL IN PLACE. FASTEN 2' FROM EACH END AND AT 3•-0' ON CENTER. CLOTH TAPE AND JOINT COMPOUND AT JOINT BETWEEN DISSIMILAR MATERIALS. \---.2 ;/TYPE �X G�DFSCH SIDE OF PARTITION END AT CONCRETE WALL OR COLUMN 3' = 1' -o' 5 /IT' TYPE X GWB EACH SIDE OF 2 -1/2' STEEL STUDS. RED IRON ANGLE AT WALLS NOT EXTENDING TO CEIUNG HEIGHT. 1/4' X 2' X 3' AT EACH LEG WITH 1' CORNER STIFFENER. • - NON - COMBUSTIBLE 2 X 4 STUD. PARTITION FREE END 3' = 1' -C' 5/8' TYPE X GWB EACH SIDE OF 2 -1/r STEEL STUDS. POWER FASTEN TO POST TENSIONED SLAB AT 2' -0' ON CENTER. 4' RUBBER BASE • STUD RUNNER h CARPET OR OTHER FINISH FLOOR MATERIAL SEE PLANS OR CONSULT OWNER. \--CONCRETE FLOOR SLAB. FOAM TAPE OR CAULK • POWER FASTENER AT 2' -O' ON CENTER NOTE: AT CONCRETE FLOOR SLAB, CONSULT WITH STRUCTURAL ENGINEER IF POST TENSIONED. PARTITION AT SLAB 3' = 1' -0' - 45 DEGREE CROSS BRACING TO STRUCTURE ABOVE AT 8' -O' ON CENTER WHERE WALLS EXCEED 12' IN LENGTH WITHOUT LATERALLY SUPPORTING WALLS. STAGGER DIRECTION OF BRACING PERPENDICULAR TO WALLS. • ACT GRID RUNNER ---__ _ ACCOUSTIC CEIUNG TILE (ACT) J -METAL EDGE WITH INTEGRAL TAPE • 5/8' GWB TYPE X EACH SIDE 2 -1,'2' STEEL STUDS. NOTE AT ROOF CONDITIONS - ATTACH TO STRUCTURAL, DECK WITHOUT DISTURBING ROOF MEMBRANE BRACING OF PARTITION AND SOFFIT 3' a 1' -0' PARTITION UNDER ACT CEILING 3' = 1' -0' RECEIVED CITY OF TUKWILA DEC 3 0 1994 5/8' TYPE X GW8 EACH SIDE OFPERMIT CENTER 2 X 4 WOOD STUDS 0 1 LI' ON CENTER • X 2' WOOD CASING • WOOD DOOR AND FRAME SEE DRAWING OR SCHEDULE FOR RATING. • -- - -4-4- -- TRIM TO MATCH EXISTING CONDITIONS UNLESS NOTED OTHERWISE. WOOD DOOR AND FRAME AT JAMB =1' -L1' re eqp 43 %:= 11 A IC-) +42 +42 4 £v Y� Q Y • D< "Q 1 4:;5 EXISTING PLAN - PARTIAL 2ND FLOOR Scvsk°4440 1/8" = 11 -0" PLAN NORTH O-- Z --< < RECEIVED CITY OF TUKWILA DEC 3 0 1994 PERMIT CENTER L L. 8 cm iz: w� w� 0 O I8 ' C n 1:4°7 E-10 W [1 o O C 4:kJ~ E--� • its ill tri 3 V W � n.4 1 oea -1310 Tar: PWI tatit felt 1 111 __ i- -, -- up 14111 111111•111 rM arta NIP aa 40•40410 lane Ear Cle 1 1 __ ■ i i 1 i EXISTING REFLECTED CEILING PLAN - PARTIAL 2ND FLOOR 1/8" = 1' -0° PLAN NORTH o—z—< < SciLkb,190 -_ _ 441■11 4•11 _-_ -044.4._ _- 0404_._.. —: Sae _— 04_04014. CITY OF l KWILA DEC 3 0 1994 PERMIT CENTER I c4' pi O E__4s.J w r6z to L Cs ° rdr) :244