Loading...
HomeMy WebLinkAboutPermit 0703 - Koll Business Center - Leader Corporation OfficesCITY OFFUKWILA BUILDING DEPARTMENT 6230 Southcenter Blvd. Tukwila, Washington 98067 Phone: (206) 242 -2177 LOCATION OF WORK / NUMBER & STREET LOT OWNER BLOCK 651 Strander Blvd. SUBDIVISION Koll Business Center, Inc. PERMIT NUMBER ADDRESS 1901 Dove Street, Newport Beach, Calif. 92660 PHONE (714) 833 -3030 NAME OF BUILDER Don Koll Northwest STATE LICENSE No. 223-01-14128 SALES TAX NO.C- 600 - 087 -861 ADDRESS 550 Industry Drive, Tukwila, Wash. 98188 PHONE 244 -5765 INSPECTION RECORD FOOTINGS BUILDING PERMIT VOID IF WORK IS NOT COMMENCED IN 120 DAYS 5/20/75 ESTIMATED VALUE OF OMPLETED WORK $ 22,000.00 00 FOUNDATION PERMIT FEE $ 100.00 FRAMING PLAN CHECK FEE $ 65.00 LATE PERMIT FEE $ TOTAL FEE li - $ 165.00 CONST. III-N NCY GROUP F -2 DAIS 155UED 9/20/75 ZONE III USE ZONE C —M EXPIRATION DATE FINAL FIRE SPRINKLERS REQUIRED MAX. OCC. LOAD 80 III Yes ENo DESCRIPTION OF WORK; Leader Corporation Offices - Tenant Improvement THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING, I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. CALL FOR INSPECTION BEFORE WORK IS CONCEALED OR POURING CONCRETE PHONE 242-2177 FINAL INSPECTION BEFORE OCCUPANCY APPLICANT BY SUBJECT TO COMPLIANCE WITH THE ORDINANC E CITY Op TIIICWII a ANIL IS RAN INFORMATION FIL .D- MEREMyITH, THIS PERMIT D. BUILDING DIRECTOR BY 1 HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS ANO THAT ALL WORK IS TO CONFORM TO T UKWILA CODES ND C._ OFD INN�ANCFS. .ti. APPLICANT BY CITY OF THWILA BUILDING DEPART EDT . _;, , 6230 Southcenter Blvd.; DESCRIPTION OF WORK: • = P. C'F -c _ • THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS. ,. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. 1 HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS ANO THAT ALL WORK IS TO CONFORM TO T UKWILA CODES ND C._ OFD INN�ANCFS. .ti. APPLICANT BY FIRE DEPARTMENT CITY of TUKWILA Barney Ruppert Building Department City of Tukwila Dear Barney: 444 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 TELEPHONE: (206) 244 -7221 Fire Prevention Bureau May 16, 1975 Re: Leader Corp. at 651 Strander ..:I:n. re.vi.ewing..the..: above mentioned,.project plans, please note the following items: 1. Four extinguishers rated "2 =A" are required. These must be evenly distributed to allow any point in the building to be no more than 75 feet from the nearest extinguisher. 2. Dry - Chem., CO2, or Halon extinguishers must be provided at locations where Xerox machines, cooking facilities, electrical panels and other hazards involving flammable liquids or . electrically energized'equipment are present. 3. Per OSHA requirements, extinguishers with a gross weight of 40 pounds or less shall be hung so that the top of the extinguisher is not higher than. 60 inches above the floor. Extinguishers weighing more than 40 pounds, shall be hung so that the top of the unit is not higher than 42 inches above the floor. Extinguishers shall be located so as to be in plain view (if at all possible). If not in plain .view, they shall be identified with a sign stating, "FIRE EXTINGUISHER" with an arrow pointing. 4. All doors, including exits shall be identified per OSHA, Section 1910.37(q). Exit signs shall have letters 6 inches high. 5. Only metal or U.L. Approved plastic trash cans should be used. 6. Provide sufficient convenience outlets in order to eliminate the use of extension cords. Please include these comments in your review of the above mentioned project. JH:vma cc:TFD file urs very truly, James Hoel, Fire Marshal leader corporation floor plan koll commerce center finish schedule