Loading...
HomeMy WebLinkAboutPermit 0768 - Southcenter Athletic ClubCITY OF(TIIKWILA BUILDING DEPARTrENT 6230 Southcenter Blvd. Tukwila, Washington 98067 Phone: (206) 242 -2177 LOCATION OF WORK / NUMBER & STREET LOT OWNER 1112 Andover Park West BLOCK PERMIT NUMBER No 768 SUBDIVISION Lincoln Properties ADDRESS 555 - 116th N. E. Bellevue, Wash. PHONE 455 -2106 NAME OF BUILDER Queen Anne Renovators STATE LICENSE NO. 223-01-15284 SALES TAX NO. C- 600 - 157 -373 ADDRESS 2205 - 2nd Ave. West Seattle, Wash. PHONE 283 -7336 INSPECTION RECORD FOOTINGS BUILDING PERMIT VOID IF WORK IS NOT COMMENCED IN 120 DAYS 9/15/75 ESTIMATED VALUE COMPLETED WORK $ 5,000.00 F9UNDATION PERMIT FEE $ 32.00 FRAMING PLAN CHECK FEE $ 20.80 LATE PERMIT FEE $ TOTAL FEE id . $ 52.80 TYPE OF CONST. OCCUPANCY GROUP DAZE ISSUED 1/15/76 FIRE ZONE USE ZONE EXPIRATION DATE FINAL FIRE SPRINKLERS REQUIRED ❑Yes ❑No MAX. OCC. LOAD DESCRIPTION OF WORK: Tenant Improvement - Southcenter Athletic Club Build Mezzanine THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. APPLICANT Sc LiT WA ATNLE. -rIC-, CLU CALL FOR INSPECTION BEFORE WORK IS CONCEALED OR POURING CONCRETE PHONE 242-2177 FINAL INSPECTION BEFORE OCCUPANCY BY SUBJECT TO COMPLIANCE WITH THE ORDINANCE •_ TTY OF INFORMATION FIL •..I1:T4S` ITH, THIS PERMI IS G BUILDING DIRECTOR BY .. ' CITY OF ,,I .,Iti `ILA BUWL • 6230 Southcenter . Tukwila, Washington Phone: (206) 242 WE G UEPART(, [' Blvd. 98067 -2177 T Z ()CATION OF WORK / NUMBER & STREET 1112 Andover Park West (Sorraeara7-,43.„ .4/444.40,tc. euv OT BLOCK SUBDIVISION • OWNER Lincoln Properties • DDRESS 555 - 116th N.E. Bellevue, WA PHONE 455 -2106 AME OF BUILDER Queen Anne Renovators STATE LICENSE NO.223,•01 -15284 SALES TAX NO. C- 600 -157 -373 • DDRESS •.2205 2nd Ave. West Seattle, WA PHONE 283 -7336 /f �C� � 4 j /U • • ESTIMATED VALUE v �'� I OF 2 1 \ COMPLETED WORK $� V I APPLICATION PERMIT FEE $ )•. '..'.',. FOR BUILDING PERMIT • 1,0 `--"� 'PLAN CHECK FEE $ �-d LATE PERMIT FEE $ 11 TOTAL FEE $j"",�`- ---... t TYPE OF " CONST. i OCCUPANCY GROUP , DATE ISSUED • ' FIRE ZONE USE ZONE EXPIRATION DATE FIRE SPRINKLERS i REQUIRED ',Yes ❑No MAX. OCC. LOAD DESCRIPTION OF WORK: Tenant: South Center Athletic Club IC 17 ._____.w In addition to work described on Building Permit /dated 7/22/75; Whirlpool, and 2nd level decking to be installed. Name of Tenant: South Center Athletic Club Nature of Business: Athletic Club THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. • 1APPLICANT Inv C Mr. > Barney . Ruppert Building Department City of Tukwila Dear Barney: FIRE DEPARTMENT CITY of TUKWILA 444 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 TELEPHONE: (206) 244-7221 Fire Prevention Bureau September 11, 1975 Re: Southcenter Athletic Club In reviewing the above mentioned project plans, please note the following items: 1. All areas are to be protected by the automatic sprinkler system. All modifications to sprinkler systems shall have the written approval of the Washington Survey & Rating Bureau, then the Tukwila Fire Department. No work shall commence without the approved drawings. Per Section 3305(1) of the UBC, "Where there is enclosed useable space under stairs the walls and soffits of the enclosed space shall be protected on the enclosed side as required for one -hour fire - resistive construction.... ". Also, sprinkler protection required under stairs. All doors, including exits shall be identified per OSIiA, Section 1910.37(q). Exit signs shall have letters 6 inches high. Illuminate) exit signs and exit direction signs are required per Section 10.113 of the Uniform Fire Code. Per UFC Sec. 10.104(b), "All doors_in or leading to exits shall be maintained openable from the inside without the use of a key or any special knowledge:o.r effort at all times when the building or area served thereby is occupied ". Walls to be fire stopped per UBC Sec, 25.17(f): 6. Fire extinguisher type, quantity and placement shall be per NFPA #10. Tentative approval was given by this office for installation of two fire hose stations. However, with the present proposed configuration of offices, locker rooms, sauna, mezzanine, etc., it appears that at least three hose stations will be required to satisfy the requirements of. Ordinance #730. *Mr. Barney Ruppert Fire Prevention Bureau Re Southcenter Athletic Club September 11, 1975 Page 2 Please include these comments in your review " of the above mentioned prciject: Yours very truly., B. RIOHAL SMITH it ASSOCIATES CONSULTING ENGINEERS September 12, 1975 City of Tukwila Department of Public Works 6230 Southcenter Boulevard Tukwila, WA 98067 Attention: Bernard Ruppert, Building Director Re: Plan Review No. 75 -S -11 Gentlemen: B. RIOHAL SMITH GARY M. SWENSON 002 COLMAN BUILDING SEATTLE. WASHINGTON 98104 Tsrarsoaa (200) 024.8180 We have received the plans for the Southcenter Athletic Club and have checked the second floor framing for a 100 pound per square foot live load. We have noted no violations of chapters 23 through 29. of the Uniform Building Code however, we were unable to check the foundation, the related support structure or floor sheathing. Please call if you have any questions. Sincerely B. Richal Smith, P.E. Structural Engineer TP:mw Enc: Set of Drawings void stud wall section southcenter athletic club luther m hintz floor plan handrail detail floor plan framing plan