Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 0797 - Koll Business Center - Dyna Gym
CITY TUKWILA BUILDING DEPARMENT 6230 Southcenter Blvd. Tukwila, Washington 98067 Phone: (206) 242 -2177 LOCATION OF WORK / NUMBER & STREET LOT OWNER 637 Strander Blvd. SUBDIVISION BLOCK PERMIT NUMBER N2 797 Koll Business Center, Inc. ADDRESS 1901 Dove Street Newport Beach, Calif. 92660 PHONE (714) 833 -3030 NAME OF BUILDER Don Koll Northwest STATE LICENSE NO. 223-01-14128 SALES TAX NO. C-600 -087 -861 ADDRESS 550 Industry Drive Tukwila, Wash. 98188 PHONE 885 -5765 INSPECTION RECORD FOOTINGS BUILDING PERMIT VOID IF WORK IS NOT COMMENCED IN 120 DAYS 10/20/75 ESTIMATED VALUE COMPLETED WORK $ 2,800.00 FOUNDATION PERMIT FEE $ 24.00 FRAMING ' PLAN CHECK FEE $ 15.60 LATE PERMIT FEE $ TOTAL FEE $ 39.60 ,90(• TYPE OF CONST. OCCUPANCY GROUP DATE ISSUED 2/20/76 FIRE ZONE USE ZONE EXPIRATION DATE FINAL FIRE SPRINKLERS REQUIRED MAX. OCC. LOAD I♦ Yes li No DESCRIPTION OF WORK: Tenant Improvement - Dyna Gym THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT•OF•WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR A/R CONDITIONING. I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. CALL FOR INSPECTION BEFORE WORK IS CONCEALED OR POURING CONCRETE PHONE 242-2177 FINAL INSPECTION BEFORE OCCUPANCY APPLICANT BY SUBJECT TO COMPLIANCE -WIT INFORMATION f4•CtED HERE BUILDING DIRECTOR BY 'LeGelsp moan asnNIdi wr•L.L.6 rw%emz.iiiTurdn;e uiter/..4.0c.. sz.,we„..zyrate.), i'VANDI4LV14 vvi41. wiWuNOoraciD6k11.14.- : • ==.1=1 c...-It.a• rivc 11 fl(_44 NORM .5FsGp.i. Pizi.AllroiN: Norraj cf.1 FLA.1.4 - Ircanai e-AtaK. i410,4 PARti-nci4 i- t. cAO:IsisT -As t-e/tw ow PLAA 1 e = —.- — =-1 WALL 1.11.114C1 CAIII.15r cyft..4-11ELVIK6 w,..---.........---...--)- 4 6 t,...t,y-ra, eilvIff>1... L,F_Caet.10 ; ; : _ 0 aver- °MIA eel, 1_,1 3 RA1.7g-gicriot..7 V e 4 ' vLY) C:.---- Q-Nu NU-1?. \....>-- -1.S.-7.7 NuMeIER 0:11-1EP.6 c.il-rfkli.„ 16 ,,,, •51-461-0AIN V er9.1-1E.S,A1-. t•Wra. 71-11 *1-15ST \ (Th ' W,A-4.-1., PINK14 [—___—_E FL.C*R. Pir-i1614 03Yrviftet. 1 . LEC.712ACAL. •(/11.4USU 1..e.6E.N1Q , 1.- - eL2i1,.T3-ex El.E.CTRicaL, OuTLET (UP 12! i. 1' e4/6 TELP-940NE. ea111-T (UP 121.sli.011.) 0 /6 Fv.r.2.74 PLJPI...a( SLScrgicAt..a..rn.,ET /6 R.LX:04. Te-efiiowe. coUTLe:r 0 r:::e1A1... ..ITI.ET 14,71ED 1 0 -4 Locg. own.cr (uP IV) . _.. wiTcA (ut) 41e) .; •TAtsiPic..19 AlteRe.,VIATI,01,4 li -"r4", a-VAL-111.1;16M)-* VriCOV r60.00J. . 64W*LPAr-S ttP NALL 4141 037 1111MCia e..Ata)nIENING .eVo' 010. 5‘.0 PFAMS ca.riERUN'a 44.4z Cl-efrg. Cauomi4 r;M c1t:46.1N nm Pt RANT ' oimiisietose:A.F6 carociftigtr..e:15,FARrrnci4 -uNi.fss5 vrtjteczyiee: NoTe P e. veatr.f.:ALL • camekfolot-1 ,1r4 4-1-17nPr "ri, Kexi; W. or! AW rAgePAS4Ce. trgS 022g '2-trbrX/1„,8 4 a 0:011.:oisit5 r:fg*N1wa4 riza En. ".514aiet de4, 5/004' 40tUNI61iPttig6 113111111M1131111 • 111111121.1 MIONIMINUENIMIESM113 MILE11111.121111111213111111 MOINIMRILIMINNIES 11A__ INIEMMINIE111112 Slimmillini#111111111MEMONN IMIIIINI11111111.11111111111111111 RakilobiaN o. 4yr75 pp-ozo-. ees.t.olvs- ia.iume ts, tenS Appiw- Trzip.c t•eku& /e4,1ece/S,4430e.0 Krrh agyteg.e. kiyal- I ,4,.1-as APPF.D 17***.N. G1YM -* ' OUTLINE SPECIFICATIONS Proposed Tenant.Irnprovements For FUTURE TENANT Building "E" M3 Complex Tukcw la; Washington 1975 OFFICE .AND RESTROOMS Interior walls: at restrocros and closure walls between office area and ware- house shall have wood or metal stud framing with 1/2" gypsum board, both sides.. Gypsum board exposed to office areas shall be taped and prepared for 'painting with skip-trowel texture , Gypsum board exposed to restrooms shall be taped and, prepared with a smooth sanded finish. Concrete walls exposed to offices shall be patched, filled, and prepared for painting as specified for gypsum board. Gypsum board exposed to warehouse areas shall be fire taped only Interior rrtovable partitions shall be ;Donn Vanguard vinyl covered. 40 lineal feet shall be provided. (with sound insulation) Carpeting shall be provided in office area #1 -only. ' 98 square yards ( see allowance ). 2 -1/2" topset rubber base shall be provided on all walls except movable partitions. allowance herculon w /70 oz. hair and ,;jut •Floor cove ng i` shall be 3/32 " vinyl asbestos tile with 2-1/2" topset rubber in all toilet areas. Office area 2, 3, 4 and 5 shall have exposed concrete floors Cell 'inns in office areas shall be suspendedT -bar acoustical tile system with 2' x 4' grid pattern. Ceilings :in restrooms shall have wood or metal joist 4, framing with 1/2" gypsurz'boaad taped and prepared for painting with a smooth sanded finish. Ceiling height in offices::1 C 0 "; ; restroorri's: 8'-0". Doors Frame °s`and Hardware. Doors shall be'prefini.shed or painted solid core' wood'zdoors in pressed metal frames All doors shall be .3' 0 x All ''hardware shall be' first class commercial grade, passage and lock sets shall be Schlage ,' ;series or ;equal, with interchangeable cores Lock sets shall be keyed per owner °s requirements. All restroom doors 'shalt have push /pull'hardrvare and?rclosers, except sinq,le occupancy restrooms , shale have privacy ]ticks.. Qf'fx.ce,7L 1$�rprovideakey locks on all office v . . conference & storage' rooms.. ,.' Y .,j t M'• r' .. t ` y me -' r ,.x�F 4't..., .. :Prefnr stied hardboard, wainiscot 4 'feet high "Niel` lite " or: equal shall be ovided on all`restroom walls ...„ ' xk' ia.i 7_+� +.,...� + i+ ' 4 F t S j,S % ,.. t t .. •• °r , Res' r-oom..A ccessories: Toilet . ti s sue' holders's hal l be pr ovided at eac 6 h watercloset anti' 1" x 22 lurr in'um framed mirrors ;and snap ;d;ispensers' %. shall be provided hi in lavatory. `Ali ther' accessories are >N.I' C. ( Not in. Contract ) . one OFFICE AND RESTROOMS Insulation: 3" fiberglas, krift faced, Batt insulation shall be provided in restroom ;malls and ceilings, walls between office and warehouse areas, and office ceilings not under a mezzanine deck. Plumbing: Plumbing shall be provided per code, including hot and cold Water` system, sanitary waste lines and vents_, and gas piping from the meter to all gas-fired equipment herein specified. Plumbing fixtures shall be .gan Ssandard or equal. W. C. CADET 2109.56 w/5330.30 china caps Lay. DECLYN 0321.26 w/pop up drain. Heating, Ventilating and Air Conditioning: Office areas 4i1 and #2 shall be air conditioned by roof - mounted" packaged heating- Cooling units. Design shall be based. on ASFIRAE ( American Society Heating,. Refrigeration and Air Conditioning Engineers,) recommended` outdoor design. tempera;rures,' and inside design temperatures of 720 F. ,( summer. )'anti 75° F. (winter) . System shall provide fresh air' as required by applicable codes . Heat nc Office areas 3, 4 and 5 'shall be heated only by using wall ` mounted electric unit heaters. Six each Bryant #53133 3000 w units shall be provided complete with fans ard'therrnostats, R'estroom "ventilatio : shall be; provided by ceiling mourned exhaust fans, ducted to roof to provide eight (8) air changes per hour. :Office olectricai Office lighting shall be provided by 2` x 4' recessed: ;fluorescent fixtures�symmetrically,spac•ed with one fixture per approximately; :64. square `feet of office area, , Toilet areas shall be lighted by, incandes centfixfures Duplex receptacles ana telephone outlet shalt be provided asshewn on office• layout; drawing. ; One switch shall be;prov ded 'for every 200 square; feet of office ..; E& h office ,area (41 (through 4 5) shall * ',have .a °separate electric meter,. One each 200 amp 110/2,20;v.. 3 phase :electric 'panel shall''be mounted on the wall dividing teach office area from , ,the'warehouse "area, provide, plug outlet n spherical shaped �neanrl. p F 1� ht n �esuxo msyand 'se orate met`e�rs e •eh unit. ©ffice'ffire, sprinklers Ofiice�s`prinkler'i eads sha`li be endant chrome late,`d heads with white' escutcheons . Location of ;sprinkler h,ea ?ds: In f �nish'Ad areas - ' "sriall °be�symmetrcal; with respect to regi terse 1igiiting, ., .and acoustical: ceiling patterns Sprinkler design criteria for^" office areas shall be based: on t e minimurri'standard1s of ,ythe Insurance Services Office (I.S O.) (National;Fire r'roteotion Association; Standard' 13 entitAe'd: "Installation "of Sprinkler Sy "stems %197 > "). • SPECIAL IMPROVEMENTS Package kitchen unit shall be provided in office #1. The unit shall have a Formica countertop, sink and refrigerator and shall have built -in shelves. Interior glass and glazing: >.Bronze glass storefront construction shall be provided on one (1) private office wall ( 121 x 9' ) of office area #1, i -i a±tE,X.iA.s...; .� `�"� ^`' �'[ ,.'.�•. . .�z / 4�: , -Yy r S vd:_ re i„t ^ i Jl .ice. -i7 as a r.�.. �^'..,.. �. fir., �;'c• d^ �'� .-�^+- ''.� ?- a ..�M _ : r WORK NOT INCLUDED ADT-tyPe alarm systems Signs or graphics Conduit or support for telephone distribution in warehouse Draft. curtains' Smoke hatches Storage racks'orm :.eri.al handling equipment Interior painting in warehouse ty , Battery dharger/;_iutlets Underfloor electrical or telephone ducts Fire extinguishers ( except hose racks required by code ) Warehouse floor sealer Floor, drains .Compressed air systems Mezzanine or stairs ;Water, gas , ,or 'drainage: 'piping` syst 'furni'shed .,by Aberthaw ) Equipment foundations, curbs "'or floor trenches Performance bond F. l Llqu d'or solid-"waste treatment facilities A rf ower operators on ov,c.rhead doors 7 Utilities i1, Reioc3tib of utilities Arc'hitectural treatment of "exterior concrete walls %In rack, sprinklers of density increase at: roof `sprinklers for future 'in rac Sprinklers WORK NOT INCLUDED Tenant dividing walls in warehouse area Wood paneling in offices Vinyl wallcoverin.g or grass cloth Drinking fountains Ceramic tile work Roof screens for 'mechanical equipment St22.