HomeMy WebLinkAboutPermit B95-0046 - PUETZ GOLF SHOP - RESTROOMCity of ?itkwil,it
(206) 431-3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
BUILDING PERMIT
Permit No: B95-0046
Type: B-BUILD
Category: ACOM
Address: 402 STRANDER BL
Location:
Parcel #: 022320-0010
Zoning: CM
Type Const: III-N
Gas/Elec:
Wetlands:
Water: N/A
Contractor License No.: TMCON**195JG
TENANT
OWNER
CONTRACTOR
CONTACT
Status: ISSUED
Issued: 03/06/1995
Expires: 09/02/1995
Suite: 100
Type of Occupancy: STORE
Slopes: N
Sewer: N/A
PUETZ GOLF SHOP
402 STRANDER BL, TUKWILA, WA 98188
FIDELITY ASSOCIATES
4211 HOLLY LANE, MERCER ISLAND 98040
T M CONSTRUCTION CO.
P.O. BOX 20820, SEATTLE, WA 98102
LARRY C. CROSS
4604 34TH AVENUE WEST, SEATTLE, WA 98199
Phone: 206 283-6205
Phone: 206 285-4300
***************************************************************************
Permit Description:
FINISH EXTERIOR WALLS, BATHROOM,
Front:
Left:
Units: 001
Buildings: 001
Fire Protection: SPRINKLERED
UBC Edition: 1991
AND FLOORING.
SETBACKS
. 0 Back: .0
. 0 Right: .0
Valuation: 60,000.00
Total Permit Fee: 762.68
**************************************************************************
• Diad4-2 LO CL5
Permit Center Authorized Signature Date
I hereby certify that I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of'work. I am authorized to sign for and
obtain this buildi permit.
Signature:_
Print Name:_
Date Ac 2
1 (p �6L
Title -
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
All PERMITS ISSUED FOR NEW CONSTRUCTION, REMODELING, OR DEMOLITION PROJECTS
REQUIRE CONSTRUCTION, DEMOLITION AND LANDCLEARING WASTE MATERIAL FROM THESE
PROJECTS TO BE RECYCLED AT A KING COUNTY LICENSED OR APPROVED FACILITY,
OR TAKEN TO REGIONAL DISPOSAL FACILITIES.
•
•
196'-0"
201-0"
20'-0'
2014"
20'-0"
20'-0"
20'-0"
16r-0"
LEGEND
❑ PROPOSED DISPLAY
NEW WALLS 3t1' MTL. STUDS
WITH Se TYPE 'X' GWB EACH BIDE
® FURRED WALL SEE DETAIL I /AI
EXISING CONCRETE WALL
EXISTING EXTERIOR FRAME WALL
FLOOR PLAN
SCALE: V8" • 1'-0"
8'-0"
HIGH MAX,
SHELVING
PANEL
LOADINGS
r
1'-I'
8 -11"
F
8'-4'
8 -4"
HOUR RATED
CORRIDOR
saw
atj.tir;
1, ,,
f "
Ld-D em'
11T•, Ur
OCOPUTEN OTT
0'-,1/4
PLOT Pi -AN
SCALE: 60' • I'
EXISTING 8"
TILT•UP CCNC
DEMISING WALL
I HCUR RATED
PARTITION %°
TYPE 'X'
BOTH 81DE8
CLUB SET
Matta
DRESS
�1
0 ° °15‘
X
°GINS AREArl ❑
0 0 . ❑
adh
0
❑ ❑ ❑ ❑
a
•
CLUB SET
DISPLAYS
0 0
0
RETAIL SALES
-
❑ ❑ ❑ ❑
TWOSTEP tree '-0",st'-0°�,
BAG -DISPLAY
f—�
DOOR SCHEDULE
CLOTHING AREA
1'-0"
121-0"
A
T-0° X 3'-0" 541 DOOR 4 FRAME
B
,'-0" x 3'-0" HM DOOR 1 FRAME
20 MIN RATING SMOKE GASKET 1 CLOSER
C
T-0° x b'-O'/ALUM STOREFRONT
t45e w46
WALK-GFF
MAT
Plan Check approvals at
nrl that the and approval ot
.,nd@rsta rssrons
the
.ta to a„urs and om
not authorize the of e" '
Fleceipt of can
odoge or or . inane@ ooca:owledtts
it id:
r'sco� F' 1
uacto
1
SEPARATE PERMIT
REQUIRED
rEECHANICAL
LECm CAL
OPLUMSIN3
0 GAS PIPING
CRY OF TUKWILA
WiLMNG DIVISION
AQPRpVE
30
anferruvicDmA
FEB 1 41995
Per CENTER
cr
00
onl
do IL
1-
Z
W
o.2
OW
co 0
cc s
oar
O�'aac
iec W pY
0. I —
Al
20F2
1
x
•
GUB CEILING
IN OFFICE
AND SHOP
�..� lame
lam
GWB CEILINGS
IN TOILET ROOMS
I HOUR RATED
CORRIDOR 2 LAYERS
I" TYPE 'X' GWB AT CEILING
REFLECTED CEILING PLAN
SCALE: 1/8" • 1'-0"
imommi
I HOUR
TWO LAYERS
B/8" TYPE 'X'
GAB • BOTTOM OF JOIST
TOILETS
•
Gamow
«mmomi
9/8° TYPE 'X' GWB
BOTH SIDES OF WALL 9/8" TYPE 'X' we
AT BOTTOM OF JOISTS
2x6'e • 16° Or.
WITH GAB CEILING
•
1
bag
immomi
1mma1
•
gal
SECTION
SCALE: 1/4° • I'-0°
bcf5e- 00q
3'-0° MIN,
GRAB BAR
3'-6° MIN.
GRAB BAR
TOILETS
SCALE: 1/4° • 1'-0"
inami
NIMINNIMIM
waciaiimiagniiwasoiloimpapx
EXISTINS ROOF ASSEMBLY
EXPOSED BAR JOISTS
PLYWOOD
R-30 RIGID INSULATION
BUILT•UP ROOFING
b48 MOP CONT.
'4° MVP BLOTWALL
FIRE BLOCKING PER
UBC 2916 (P)
R-I9 BATT
INSULATION AT
EXTERIOR WALLS
n
D11" MTL RJRRING
• 24° 0.C.
•
•
°
°
•
•
ALL SECTION
SCALE: 3/4" • 1'-0"
2x6 • 16" 0.C.
R-19 BATT
5/8" TYPE 'X' GWB
SLOT WALL FINISH
EXISTING 08B
EXISTING DRYVIT SYSTEM
EXISTING UJALL SECTION
SCALE: 3/4" • 1'-0"
APPROVED
h , • 3 1995
RUILOING DIVISION
arrirvEDo mown*
FEB 1 41995
paw CENTER
Z
W
a.
_ -
COCCm
D.
COImp
NI
�WNY
A2
2 oFa