Loading...
HomeMy WebLinkAboutPermit D02-039 - JOHANNESSEN RESIDENCE - ADDITION, DECK AND REMODELD02 -039 JOHANNESSEN RESIDENCE 13930 56t" Pl. So. EXPIRED Public Works Activities: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0002800003 Address: 13930 56 PL S TUKW Suite No: Tenant: Name: JOHANNESSEN RESIDENCE Address: 13930 56 PL S, TUKWILA, WA DEVELOPMENT PERMIT Owner: Name: JOHANNESSEN ALLEN Phone: Address: BROWN TINA, 13930 56TH PL S Contact Person: Name: ALLEN JOHANNESSEN Phone: 206 - 246 -5911 Address: 13930 56 PL S, TUKWILA, WA Contractor: Name: A J CONSTRUCTION INC Phone: Address: 13930 56TH PLACE SOUTH, SEATTLE, WA Contractor License No: AJCONI *04400 Expiration Date: 09/04/2003 DESCRIPTION OF WORK: KITCHEN ADDITION (135 SQ FT), COVERED DECK AREA ADDITION (128 SQ FT) AND REMODEL ATTIC TO ROOMS. Value of Construction: $45,000.08 Fees Collected: $1,000.03 Type of Fire Protection: N/A Uniform Building Code Edition: 1997 Type of Construction: Occupancy per UBC: 7 Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Water Meter: Channelization / Striping: Start Time: Private: N Private: N ** Continued Next Page ** D02 -039 Permit Number: D02 -039 Issue Date: 05/15/2002 Permit Expires On: 11/11/2002 End Time: Public: N Public: N Printed: 05 -15 -2002 z Z JO . 00 N CO I .. J N u. w u. w = al Z F O Z1-- 11J Lu U 0 0 ( -2 , ua u j H r- co W Z _ O 1-" . Z J Signature: Print Name: doc: Devperm City of Tukwila Department of Community Development 16300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform ce of work. I am authorized to sign and obtain this development permit. Z)41/..t Date: /S 2 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D02 -039 Printed: 05 -15 -2002 Parcel No.: 0002800003 Address: 13930 56 PL S TUKW Suite No: Tenant: JOHANNESSEN RESIDENCE 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All mechanical work shall be under separate permit issued by the City of Tukwila. 6: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 7: Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 8: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 9: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 10: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 11: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name. doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 //ci-/-* i' g7/t PERMIT CONDITIONS 002 -039 Permit Number: D02 -039 Status: ISSUED Applied Date: 02/05/2002 Issue Date: 05/15/2002 Date: —/$' 72- Printed: 05 -15 -2002 Project Name/Tenant: / / / /7 '''.74/,•/---/"..1.1'e--z- Value of Construction: / Age Site Address: / , ---- City State/Zip: , 2$ s P s �ti ei4 / � � t2 Tax Parcel Number: Phone: 7O / 2w . __ a7// Property Owner: / J / 4/f Floor Area Ratio: (total floor area of all structures divided by the area of the lot) /7, > 3 Street Address: _ City State /Zip: Sig �� -� CC Fax #: Phone: " Provide documentation that shows the principal owner lives in one of the dwellings as his or her primary residence. Contractor: Street Address: City State /Zip: Fax #: Architect: ,...5; A7,-C e_____ Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: Phone: Street Address: City State /Zip: Fax #: Description of work to be done: r/y /, eX A,, f •„_,, y C � , ,E zr jr , /if el 7∎ YUV,44f' Type of work: ❑ New Single- Family Residence ❑ Addition - Single - Family Residence ❑ Interior Remodel- Single- Family Residence 71 Residential Accessory Structure* A Remodel /Addition to Accessory Structure In Garage(s) Decks) - Covered & Uncovered ❑ Residential Reroof Is this,site served by: /a Sewer ❑ Septic (King County Health Dept. approval required - 296 -4722) Existing Square Footage for Structure: '5,0S sq. ft. Dwelling /37?Mai'NN,v, 70 6; sq. ft. Covered Deck(s) 910 g' sq. ft. Garage /Carport sq. ft. Accessory Structure(s) sq. ft. Uncovered Deck Proposed New Square Footage: / 3 5`' sq. ft. Dwelling / 2_ _ e " sq. ft. Covered Deck(s) sq. ft. Garage /Carport sq. ft. Accessory Structure(s) sq. ft. Uncovered Deck Floor Area Ratio: (total floor area of all structures divided by the area of the lot) /7, > 3 *For an Accessory dwelling, provide the following: ``: Lot area Floor area of principal dwelling Floor area of accessory dwelling _ " Provide documentation that shows the principal owner lives in one of the dwellings as his or her primary residence. • '•::4:x.1 ilargagerity1 CITY OF TUKwILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 SFPERMIT.DOC 2/13/97 :: i "•p" ;.'e'�k ±:r>i'i „ >;r,qr�,:, :,.5x:u'�'Y•"Tftnxfvi.,, » • ss. • ••= - • .. • • ,,......... Fs R STAFF USE ONLY Project Nuruner: Permit Number: DOau 03q Single- Family Residential Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. • APPLICANT. REQUEST FOR.PUBLIC;WORKS;SITE /CIVIL PLAN.REVIEW OF THE FOLLOWING:::`: - (Additional redlews shall'be:determined by,thePublic Works Department) :. . ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone ❑ Hauling ❑ Land Altering: 0 Cut cubic yds. 0 Fill cubic yds. ❑ Moving an Oversized Load: Start Time: End Time: ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be re- viewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall ex- pire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application = .2- w01 Date application expires: Applicat taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM Z w t 1 J O 0 CD CO IL J t- � w w 2 LL. co I W Z = F- ZI- w W Ucl O 0 H W 2 h-� LL O W Z U= 0~ Z 'BUILDING OWNER OR AUTHORIZED AGENT: Signature: ` � "�� • . ; 'ii. . ....$ Y . Date: " . ' ' K v , at Print name: Phone: Fax #: Address: City /State /Zip: r ALL SINGLE- FAMILY RESIDENTIAL PERMIT APPLICATIONS MUST BE UBMITTED WITH THE FOLLOWING: ➢ DRAWINGS PREPARED B'. REGISTERED ARCHITECT OR PRA £SSIONAL ENGINEER MAY BE REQUI9ED BY T,H BUILDING OFFICIAL ➢ ALL DRi4VVINGS'SHA L BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Copy of recorded Legal Description from King County ❑ ❑ Certificate of water /fire flow availability (Form H -11a). Contact the Public Works Department (206) 433 -0179 for servicing district. ❑ ❑ Certificate of sewer availability (Form H -11). Contact the Public Works Department (206) 433- 0179 for servicing district. ❑ ❑ Metro: Residential Sewer Certification (if Tukwila Sewer District) (Form H -12) ❑ ❑ King County Health Department approval for septic - 296 -4722 Four (4) sets of working drawings, which include: Site Plan (see example Form H -16) 1. Existing fire hydrant location(s). 2. Proposed access road. 3. Driveway location- driveway shall be 10' wide minimum and 20' wide maximum. If driveway is over 150' long, driveway shall be 20' wide and have an approved turnaround (City Ordinance 1741). 4. North arrow and scale. 5. Building setback from property lines. Any proposed or existing easements must be shown on plan. 6. Public Works review requires the following on site plan: driveway location (10' min., 20' max. width), show proposed and existing power, water and sewer lines, existing storm drainage system, downspouts and foundation drains, and where drains tie -in. 7. Parking plan. 8. Lowest building elevation (if in Flood Control Zone). 9. Estimated /proposed topography at 2' intervals and proposed elevation of lowest floor level. 10. Identify location of sensitive areas slopes 20% or greater, wetlands, watercourses and their buffers. 11. Identify location and size of significant trees that are located in sensitive areas and buffers or the shoreline zone. Of those, identify which are to be removed (Title 18, City of Tukwila Zoning Code). 12. Identify location of high water mark of the Green /Duwamish River if site is located within 200' of the high water mark. 13. See Public Works Checklist for detailed site plan information required for Public Works Review (Form H -9). ❑ ❑ Foundation plan and details ❑ ❑ Floor plan ❑ ❑ Roof plan ❑ ❑ Building elevations (all views) ❑ ❑ Building height ❑ ❑ Building cross - section ❑ ❑ Structural framing plans and details necessary to completely describe construction ❑ ❑ Washington State Energy Code Data (Gas /Electric /Oil /Propane /Heat Pump) Form H -15 available at Permit Center OR Prescriptive Heating System Sizing Chap 9 Form H -6. ❑ ❑ Complete Land Use Applications if not previously submitted (i.e., Reasonable Use Exception, Variance, Shoreline or Tree Permit). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance and other land use or SEPA decisions. ❑ ❑ If dwelling has a septic tank, and a bedroom or bathroom are added, provide written approval from the King County Health Department or the Tukwila Public Works Department prior to submittal of permit application. ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". ❑ ❑ Building Owner /Authorized Agent . If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the. State. of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit Will be required as part of. this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, SFPERMIT.DOC 2/13/97 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0002800003 13930 56 PL S TUKW ALLEN JOHANNESSEN RESIDENCE R020000164 KAS 1684 ALLEN JOHANNESSEN Payment Check Current Pmts Amount PLAN CHECK - RES 4539 Type Description RECEIPT Method Description 000/345.830 Permit Number: Status: Applied Date: Issue Date: 385.61 Account Code 385.61 Total: 385.61 D02 -039 PENDING 02/05/2002 Payment Amount: 385.61 Payment Date: 02/05/2002 04:31 PM Balance: $597.75 ( 52/07 V716 TOTAL. 305.61 Printed: 02 -05 -2002 z RECEIPT , l Z re 2 Parcel No.: 0002800003 Permit Number: D02 -039 U O Address: 13930 56 PL S TUKW Status: APPROVED N Ca to w Suite No: Applied Date: 02/05/2002 w = Applicant: JOHANNESSEN RESIDENCE Issue Date: v i i F- O W 2 Receipt No.: R020000650 Payment Amount: 614.42 g Q, Initials: SKS Payment Date: 05/15/2002 12:55 PM _ C • a User ID: 1165 Balance: $0.00 I— _ Z f- 1-O: Z1-- U0 TRANSACTION LIST: i t_- Type Method Description w w LL - ~O Payment Check 4506 614.42 lilZ. U N . O l- z Payee: ACCOUNT ITEM LIST: doc: Receipt City of 1ukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 A J CONSTRUCTION INC Current Pmts Amount BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE Description Account Code 000/322.100 000/345.830 000/386.904 603.35 6.57 4.50 Total: 614.42 lr 1. '. ;.L') "1::11 f:li. :51 I. y .. 42 Printed: 05 -15 -2002 Prpject: J ohii kin r sciq/1 qeS. ,-- - Type of-inspectio : I n ei Ad_drls: _ _ co. pi_ 5 . 3 `30 s i 1: 4 1 03 Date 07 Specia Instructions: d: I Date Wante I ( 1(2, Request r: AI \ ein Phone No i';'' r'.: •• n, fee must be -nedule reinspection. tihr.;•.r.11.1.1**.4.4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ZAP proved per applicable codes. COMMENTS: $47.00 REINSPECTION FEE paid at 6300 Southcenter Blvd • PER 431-3 Corrections required prior to approval. • z r4 w JO 00 (0 0 • w • w (/) j 0 5 Li.. ▪ a 1— MI Z 1.- 1— 0 Z LIJ UJ 0 O 1— w I 0 Z 0 O I- PrDje t: •-) Ohl nil eSCrl ?' eS. Type nspectio Inc : Ades o �5L0 + L `� 11 r3 Date Ce l: z4 V Special Instructions: Date Wanted: d: a.m ! �1? P.m. Request dr : Allen Phone No• ((�,, !I ,,, ( -9(/V -. L1'l" Sq it INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Vetivv,i Cow I�e inspector: ' El Corrections required prior to approval. El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: �:.delGlX»tiif54Y` "Rr�'i ��'. ^,�';'�?,;1 ?':::.: < ...�''u.:�:`• °.�.::..... .,,..._ �... Z I W J U . 00 N 0 CO U.1 J H �LL W ° g5 u_? _co d = W zI Z O W • N O F_ W W u- LLl Z U CP- I= O 1- z 3 oject: jj e pe of Irlspecti� )� t i Address: 1.37C) Sti94 4 (. S, Date called: � i Special instructions: . Date wanted: b p 0 p.m. Requester P"y ., J e 24 Lke 5? 11 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit c i1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila WA 9818 PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: 5- $47.00 REINSPECTIO E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Z Z . 6 J U U O . NO Ill H • _ CO W L u O' g J u_ < = w ? �. Z° • Lu 2 p U ,O 0 I— W H H • O .. z — = : O I` z Projec , �4J /� ,&s , Type I : - - of Ion / e /(i r»i .! V L, I_ . ddr S . Date ced / /0 j Special instructions: Date wan d: T r-,) / n8 ' am . . p.m. Request r• Phone: 41 e .t'o4c u:rtVnS INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. Receipt No: INSPECTION RECORD Retain a copy with permit PERMIT NO. (206 4 -3670 Corrections required prior to approval. El 00 REINSPECTION FkE REQUIRED. P !or to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: COMMENTS: Dat y Z_ re 2 J 00 co 0 W = J H CO u_. wO LL Q = a w z � Z O -. o 1- wW H� O W Z 0- z 3 oje i ct: _. ohrctelhessol 'R.'s. T.pe of Inspection: trctAry\ 11A te : Address r3gO 51e PI, 5 Da c lied: j 1 31 02— Special instructions: Date : P.m. Requ Ster. A1 )- PA (1 Phojle: — si lt INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 INSPECTION NO. PERMIT NO. (206)431-3670 Approved per applicable codes. ri Corrections required prior to approval. COMMENTS: Inspector: Date: 8 -1-62 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project: \ ()� G r s vv Type of Inspection: FAT I rn, AltlS 5 L P1 S Date called: 1 -� O Special instructions: (r) Date wanted: / L a.m. - 7 - V co P.m. Requester: I '7(1 Phone: 1 ( to — 2 L i t)" S 911 I' INSPECTION NO. • INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 �l S3�t�'iSE�t�fi�il�.�tl��,liaNt� ��.:.'& s �u�• i�4' cUiK ;�(.�}�'�Y,�:;��'' » *9 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ti t -1 : Grp F l0 p r O 1nJ1r� \/P rl 117)\.10( (pct ►M h(' 1 Inspector: C V j (9 A Date: �() _ O .� 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: i:S�:a„S3t. n;lA .Kidd 14:if 4.1iY;1:tr: i4.4.44041'm Z Z. re W 6 JU • co U c rn w J H U) O J za I— w Z H. 1.O LU O v' 0 I-- w w U 11 0 .. z U N Z Project: , i liuind444 red-wnt? JD c Type of In /4-4k. IA ia i Addres : 1 030 5, Date call d: i i 23(Da S e ial instructions: :,.. , - J ,--., Date wanted, l 2_ a.m. ..... i I q Requeste4 _ fr e...4,1.... Phone: IC ( JP e ' te.0140A.4;11 • . INSPECTION NO. CITY.O TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit ft PERMIT NO. 8 's (206)431-367Y Corrections required prior to approval. COMMENTS: I -re 1-1--e") A-t:> • 41111146: c!::: 1 I ...... tA—.......) 0 a ..47.00 REINSPECTIO FEE REQUIRED. Prior t a t 6300 Southcenter Blv ., Suite 100. Call to sch Receipt No: Date: inspection, fee must be paid dule reinspection. Date: 1 INSPECTION NO. CITY:OF TUKWILA BUILDING DIVISION: 6300 Southcenter Blvd, #100, Tukwila,:WA' 98188 Special instructions: -TYPe Inspection: .Gc. f h �j Date cal 7 /°Q .Reques eri lC n Date Pho 6 p(d' o f /(p . 5m pproved per applicable codes. Saltitattatieremokeluteuthew INSPECTION RECORD Retain -a copy with permit PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: /Je CO 4:1 4 -PV■ greet Inspecto . `' ` ^� 4t, C ...(r. Date: g Oq $47.00 REINSPECTION.FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: 'F ` 's' } Catl ".cirY.i .� 7�:.'S, g ..'Yf ; ��'l '`' y � ' s � � • c b!... . Z • = U0 W = J H U) w w J = d: Z ZO 0 p' uj 'O D WW I H — 0 Z W U =' 0~ z ? roj ct: fr l f'717e:S fi f Alva enc. Type of Inspection; , . ' ' - ktot- / �1 I tit Address: / L 56 / . Date all i, 0/ Special instructions: Date nt I , (� a.m: p.m. Requ,eft �Cf, 14 PhoneL a ' Zito ^ / / iski INSPECTION RECORD Retain a copy with permit INSPECTION NO. - CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tulkwila;'WA 98188.. Fu�i.fic*c+4 PERMIT. NO. 1 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: co-CV' e ve t M (, -S+ W a I ()V__ -17) ,s\Ae, Inspector:` i;j19 Date: 64 J d`0Z El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: vLt y� , !�b: i'A4w �ro� .�.�,+�{' '. r «,kl' " St�..s:�L xr, Y, z}�:', ".]! J"`4 +�• C'+i y 44 Z Z . CC W UO (!) 0 ' J H WO u. Q. w d H = . Z F. z0 W • p O co O I-- W • W F H Lll Z U =; O ~ z Project: Project: Type of I spection: . 1r 0.444A 46,,E Date called: t I7 - Address: /3930 61 PI 5. Special instructions: Date wanted: a.m Requester: A� , WAIAll Phone: " (2Ob - Sgif i:11.1 Ibtiei- g/iii/v!u rYhi�d� ti INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 K Approved per applicable codes, 0 Corrections required prior to approval: COMMENTS: I—d(l)er VP 0 k- 4 0" 1 "‘ Inspector: Q f t.9. Date: [0-18 - 0 2 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: y: %F1.A{It l«4?:LtNS:1M1!r�`�� PERMIT NO. (206)431 ` 3670 , Z Z QQ W 00 co co w J = I- U) w w u_ ? Cy _ ` z °. LU U � O N w W Z 111 U= 0 Z INSPECTION RECORD Retain a copy with permit INSPECTION NO.' ITY,OF BUILDING DIVISION 300 Southcenter Blvd, #100, Tukwila, WA 98188 pproved per applicable codes. • RMIT NO. (206)431 -3670 ;'Address:.: Special instructions: Type of Inspection:. Date called: - 3/ -0,2 Date wanted: - e p. m. Requester: Phone: ,2 & 07 Corrections required prior to approval. COMMENTS: Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: A a s Z ~ W CC 6 O 0 co 0 W = -J W 0 I L off' 0 WW n: c) ~ Z W z INSPECTION RECORD Retain a copy with permit INSPECTION NO: : ITYOFTUKWILA BUILDING DIVISION 300 Blvd, #100, Tukwila, WA 98188 ett ;W)5 PERMIT (206)431 -3670 Typg of lris " f L 1 ` �� 6 1'x'1 Ad re Da te called: Date wanted: & MAP' Requester: At esei Ph°7;0'6 r - 6 -- 5 V Approved per applicable codes. E] Corrections required prior to approval. .COMMENTS: t A4I0VS av \ Inspector: Date: S_ 2. - 0 2 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Z • W U O to 0 . W = J F • u. W 0 ▪ _ CO = W H Z � ZI- W • W U O - O I— W W ~ ♦- LL' O Li; I z January 7, 2003 Allen Johannessen 13930 56th Place South Tukwila, WA 98168 RE: Permit Application No. D02 -039 13930 56th Place South Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the-date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is: commenced for a period of 180 days. Based on the above, you are hereby advised. to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final Inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, .the. Building Code does allow the Building Official to approve a.: -time extension up to 180 • days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to February 2, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefanie Spencer Permit Technician Xc: Permit File No. 002 -039 Bob Benedicto, Building Official City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431 -3670 • Fax: 206- 431 -3665 z Z . [Y W 6 UO W J i— u LU J. LLa I z �. O z F— tu U � O — 0}- W W • O . z, U 6 rz O . z February 22, 2002 Allen Johannessen 13930 — 56th Place S Tukwila, WA 98168 RE: CORRECTION LETTER #1 Development Permit Application Number D02 -039 Johannessen Residence 13930 — 56th Place S Dear Mr. Johannessen: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Division. At this time, the Fire Department, Planning Division and Public Works Department have no comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206)431 -3670. Sincerely, Brenda Holt Permit Coordinator encl xc: File No. D02 -039 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 4(4- 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206-431-3665 14 11010 1 11M 41.004,10 V16141Watifit***AleilWi MAW NAM 14100103 Of4 saert BUILDING DIVISION REVEIW Date: Feb. 20, 2002 Project Name: Johannessen Residence building permit application Application #: D02 - 039 Plan Review: Ken Nelsen, Plans Examiner Only one significant concem arose during the plan review as follows. Because of the unusual construction, methods and materials proposed for the addition, further information is required. Specifically, the gravity Toads on the steel column supports, column footings, the beam hanger connections, beam sizes and the overhanging roof beam connection, must be provided with a engineered structural analyses. The structural analyses should be completed and stamped by a Washington State Licensed Engineer. No further comments at this time. Tukwila Building. Division 6300 SouthCenter Blvd. Tukwila, WA 98188 206 - 431 -3670 H R HARTING, JR. /CONSULTING E'NGINE'ER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (206) 271 -4242 JOB NO: 02 „ SUBJECT: ROOF - LL= 2.5 (s L I d w ) FLOOr - LL -40 F (REST p.) FILE copy CITY Of TUKWILA APPROVED MAY 14 2002 SHEET! RECEIVED CITY OF TUKWILA APR 19 2002 PERMIT CENTER EXPIRES 11/7/03 roof framing bearing wall H R HARTING, JR./CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (206) 271-4242 JOB 30k t■ () \ c: 5 JOB NW n?" DATE' /01 By, t" SUBJECT! P SHEET' H R HARTING, JR. /CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (206) 271 -4242 JOB! bi 9:75 t. t" rtA JOB NW CA-k`1 DATE! 'W 1 BY! < SUBJECT! SHEET' end bn over deck side deck beams H R HARTING, JR. /CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (206) 271 -4242 JOB N❑, f SUBJECT SHEETS columns roof framing H R HARTING, JR. /CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (206) 271 -4242 JOBs Jo 1-1 M)1. 7 c... M613 JOB N❑,s Off „ DATES SUBJECTS f O XL f \l444 k iX 2i. ?X SHEETS deck joists floor joists K R HARTING, JR./ CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (206) 271 -4242 JOB' b111C)L JOB NO rn: DATE' 1 "• I 1 {Q2.BYr ' SUBJECT' F= floor beam at addition kitchen deck beam H I? HARTING, JR. /CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (425) 271 -4242 JOBS J JOB NO O I t`1 DATE' ` 1 � 5t� By,` H SUBJECT' corner column kitchen perimeter window header stair deck header H R HARTING, JR./CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (425) 271 -4242 headers over bathroom header adjacent to bathroom JOBS , JOB NO,+ SHEET If R HARTING, JR./CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (425) 271-4242 JOB NO y SUBJECT Pt L.) cube. CP.M-At basement beam north side K R HARTING, JR. /CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (206) 271 -4242 JOB N❑ 1 02 -11 DATE+ 4 / Ys $ 4 SUBJECT basement beam column and bearing footing new addition framing cantilevered joists H I? HARTING, JR. /CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98055 PHONE (206) 271 -4242 JOB N SUBJECT, DATE1 t1 N t? JOB: - BY l SHEET, cantilevered joists with wall above post load N R HARTING, JR. /CONSULTING ENGINEER 212 WELLS AVE. S., SURE F, RENTON, WA. 98055 PHONE (206) 271 -4242 JOB NO (2`11 DATE, /OLBY' 4 t SUBJECT, M, t t SHEET addition beam H R HARTING, JR. /CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F. RENTON, WA. 98055 PHONE (206) 271 -4242 south footing center footing north interior if R HARTING, JR./ CONSULTING ENGINEER 212 WELLS AVE. S.. SUITE F. RENTON, WA. 98055 JOB NO • - I DATE/ P BY1 SUBJECT' U header at east existing face of wall i N BO deg. 50'80 E 123,01 56TI- PL. S. NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 5 84 DEG, 55 W 214,61' LEGAL DESCRIPTION: THAT PORTION OF THE JOSEPH FOSTER DONATION CLAIM No.39 IN NORTHEAST QUARTER OF THE SOUTH WEST QUARTER OF SECTION 4. TAX ACCOUNT NO. 000280 - 0003-05 RESIDENCE OF ALLEN JOHANNESSEN 13930 56TH PL S. TUKWILA, WA 98168 SCALE- I" • 20' FIRE HYDRANT PROPERTY LINE N 85 deg, 30'43" E 12 ROOF DOWNSPOUTS • NEW KITCHEN ADDITION DM- 03C1 i i I i ' RECEIVED i C11 OF TUKWILA PERMIT CENTER PLOT PLAN DEPARTMENTS: v Public Works k9r1 414 2J1 -0 TUES /THURS ROUTING: Please Route PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -039 PROJECT NAME: johannessen Residence SITE ADDRESS: 13930 56 PI S A t. Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # DATE: 2 -6 -02 SUITE # After Permit Is Issued C DETERMINATION OF COMPLETENESS: Complete Fl I Comments: Fire Prevention w1 '+ - Structural Incomplete Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (4 weeks) Approved Approved with Conditions n REVIEWER'S INITIALS: Mnreek ► 1 I fey Cid CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 REVIEWER'S INITIALS: Approved with Conditions (Tues., Thurs.) I I 2- Z2 PERMIT COORD COPY Planning � Division n(� 2 -'-o2 Permit Coordinator DUE DATE: 02-07-02 Not Applicable No further Review Required DATE: DUE DATE 03 -07 -02 Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) DATE: z ~ w et 2 - J U O • 0 U.1 F- • w w 0 2 gQ = • d w Z = w U � 0- 0 w " Z di co 0 z Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued Project Name: JOHA.NNESSEN RESIDENCE Project Address: 13930 — 56 Place S Contact Person: Allen Johannessen Summary of Revision: City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: cE ntered in Sierra on Plan Check/Permit Number: D02 -03 9 RECEIVED 0ITY OF TUKWILA APR 1 9 2002 PERMIT CENTER Phone Number: .2a6 1 0 J 7// 02/22/02 registration # CITY OF ) UKWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON COUNTY OF KING , states as follows: 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. /2 , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. PERMIT CENTER H -4 CITY RECEIVED A ` ' LICANT Signed and sworn to before me this 5+-11 day of Fe b ru ary , 20 0 2 . a &_ a. 4 NOTARY PUBLIC in and for the State of Washington, residing at ki Name as commissioned: My commission expires: County. Alice A. Deacy f7 --I b~-0 q li + JiF,ll z -Z • QQ • � J O 0 • 0 CO N w 0 LL co I w z � F-0 Z I- w uj U 0 O ( o �- wW ``o .z w U = O z 18.27.090 Exemptions. This chapter III not apply to: 1. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply . to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division AFFCONT 1/13/00 +G of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work. z ~ w CC 00 0 cow J F- N LL w u. co = F.w Z = O Z w • w O • N O I- w W L I O w Z U= O ~ z EXISTING STAIRS _ BASEMENT FOUNDATION PLAN EXISTING DECK ,- WALL REMOVED NEW 5 I /4X 9 I/2 PARA -LAM ABOVE CEILING \ \ \ XISTINCs KITCHEN SECOND FLOOR (MAIN FLOORS KITCHEN EXTENSION PLAN 1y z O - - MICROWAVE ABOVE FILE COPY I understard that the Pan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt o len ed. tractor's copy of approved ptu' s acknowledged. Permit No. Do Z'Q_ THIRD FLOOR (TOP FLOOR) PLAN SEPARATE PERMIT RE" `JIRED FOR: W '' :CHANICAL LECTRICAL T- LUMBING ['GAS PIPING CITY OF TUKWILA BUILDING DIVISION FSERG_A8 CLASSIC COL,r- - EACN SDE OF DECK /ATTIC ACCESS UNDER NDOW ELECTRICAL t3 SWITCH OR THREE WAY 0 5" CANISTER LIGHTS (SEALED TYPE) TTIC SPACE d o, OUTLET, GFCI COUNTER, ALSO FOR MICROWAVE, OVEN, STOVE, REFRIGERATOR, NE'3...PPOR DECK 1 ;? SMOKE DETEC EXISTI\G'STAIAY S•40RT WALL WA.L TO BE REMOVED NEW DcTENS ON OF UPPER RENO '✓AT'ON �6 -O x 4 -O NOTES FOR UPPER LEVEL (THIRD FLOOR): I. ALL NEW WALL 2X6 CONSTRUCTION W/ R -19 INSULATION. 2. NEW 2X8 FLOOR RAFTERS SISTER ALONG SIDE OF EXISTING 2X4 CEILING RAFTERS. 3. 4 EA. 36" DIAMETER WINDOWS MIL CARD WHITE VINYL INSULATED GLASS. 4. I EA. 36" FRENCH DOOR TO SIDE DECK. (SOUTH) 5. 1 E.A. 5'0" DOUBLE FRENCH DOOR TO BACK DECK. (EAST) 6. I EA. 12 1 X48" BAY WINDOW WHITE VINYL MILCARD INSULATED GLASS. 1. NIP TRUSS SET BY TRUSS MANUFACTURE. 8. REMOVE EX STING ATTIC ROOF WHERE NEW ADDITION IS TO BE BUILT, 9. ATTIC INSULATION R -30 10. ELECTRICAL OUTLETS AND CEILING LIGHTING. NOTES FOR KITCHEN LEVEL EXTENSION: I. REMOVE EXISTING KITCHEN EXTERIOR WALL AND INSTALL NEW 5 1/4 X 9 1/2 PARA -LAM TO BE SET UP EVEN WITH CEILING. 2. INSTALL NEW 12 "X48" BAY KITCHEN WINDOW WHITE VINYL INSULATED GLASS. 3. PLUMBING FOR SINK, DISHWASHER, TO BE EXTENDED. 4. ELECTRICAL OUTLETS (GFCI) AROUND COUNTER AREA, AND FOR MICROWAVE. 5. NEW EXTERIOR WALLS 2X6 CONSTRUCTION W/ R -I9 INSULATION. 6. FLOORING TO BE PREPED FOR CERAMIC TILE. '1. NEW CABINET SET. 8. EXTERIOR WALLS TO MATCH EXISTING CEDAR SIDING. S. EXTERIOR SHEATHING I /2" 058 WITH EXTERIOR BUILDING PAPER 10 EXTEND EXISTING FLOOR LEVEL WITH NEW 2X8 FIR JOIST. INSULATE WITH R -28 _ADDITIONAL SQ FOOTAGE: MAIN FLOOR KITCHEN = 136 SFT. TOP THIRD FLOOR . 214 SFT. TOTAL ADDITIONAL SFT, = 410 SFT. ALLEN JOHANNESSEN 13930 56TH PL S. TUKWILA, WA. 98168 SCALE 1/4" = 1 DATE r 9 -!AT VG CO�.MP. ____- c: -AS CLASSIC COL r"P18 RALJN6 'O AT C.4. DC STING -DECK QAIJ�ts 5. NO I C.orredio H bOo39 206- 246 -5911 HOME PHONE 206- 248 -8968 FAX KITCHEN ADDITION AND THIRD LEVEL REMODEL RECEIVED CITY OF TUKWILA APR 19 2002 PERMIT CENTER PACE 1 4 BOX CAP TOP OF COLUMN CAP (TO MATCH EXIST CAPS) SECTION ,4 DETAIL 4X4X1 /4X0'1" ANGLE GLUE LAM TOP VIEW CORNER CONNECTION - FRONT VIEW SCALE: 1/2".1 TOP VIEW S IDE VIEW SCALE: I /2 " =1' SIMPSON 1212T EA. SIDE MAILED E :0:1 LY P.000 1 ,A, 2X8 • 12" O.G. 5 1/8 X 9 1/2 GL 3/8" ACX SHEATHING PAINTED — 4x4 POST v2" T ` ' —1/2" TILE ON TOP OF 1/2" CEMENT TILE BACKER OVER 5/8" CDX SHEATHING OVER 3/4" CDX PLYWOOD SHEATHING GLUE AND NAILED TO FLOOR JOIST SECTION 13 DETAIL 8 -2 CENTER COLUMN TOP VIEW CORNER COLUMN TOP VIEW SCALE: 1/2 ".1' SIMPSON P5120 DD :k SECTION C H B14ORT WAIL ' -.:w 0 -1 G'A . . - . . q 1 _ - °I j 2X10 GIST SISTERED ALONG SIDE EXISTING 2X6 RAF i tRS TYP. TOP FLOOR 12 II I A 4 G ' A 4 G •A 4 G, o 4 G s'A . D 4 A o A D A o A ' D D o p° 4 A O A O° p° , G'o . r SOUTI4 sIL7E VIEW °{ d ?ce Db2.--o5•7 4 1• 4 4 4 ►i1P 'T.t'..55 SE" BY TR•66 ImARLFACraitE SCALE I /4" DATE 4 ' C ' 4 ' G'n. . SECTION D . iirilafterikaTmeilarrar iMil■ I•■rlrrrrrr II■rrr rrrrrr■■r r rrrr r r■�ir. l�r rr ` rr ` IllEm � r1•■ r\ •r■ ii r a . r 1 � .41 /rrrrrrrrrrrrrrrr� rrrrrrrrrrrrrrN■rr �rrrrrrrrrr�■rrrrrrrrr. �rrrrrr■0.■rr■ r■ .rr.INrrI■ rrrrrrrrlr■�r■�rr�rrrrrr � , .r■■rrrrrMrOIMMIM irrrrrrrMrrrr .. rrrrrrN II A yh ,-{,H 4 ° 4 ° 4 • • . G'A . 6'A . Gm . D'A • A ) o D ' D D D A D O A O A O A O • o . G'A . G•o . ^, „A . D D D D D A D A D ., A p A O A O A 4 4 • 4 • 4 . 4 . G•A • G'A . G'A A �e ° O A O , O 4 4'A G'A ° 4 • • 4 • 'o .4% • G'n 0 v ' L 4 • • 4 -° • 4 A 'A . Q'A . G'o . • Correthor n ort\i NO. U ALLEN JOHANNESSEN 206 -246 -5911 HOME PHONE 13930 56TH PL S. 206- 248 -8968 FAX TUKWILA, WA 98168 RECEIVED CITY OF TUKWILA APR 19 2002 PERMIT CENTER KITCHEN ADDITION SECTION DRAWINGS PAGE 2 '� r EXISTING 4X10 BEA MAIN FLOOD' FRAMING PLAN lnO PR:, / DE - s18 AT EA. .O ST TO STUD OR BEAM -r.. PRC✓IDE LTT22O AT EAC1- MICRO -I-A - ' STUD TO CONC'' 1 A_'9;2\ATE STUDS - L- 4 FOXY 3ROt. r2' D 4X6 HDR 5 1/4 X .1 I/2 PARA -LAM (PSL) EXIST,2X6 CLG JOIST .16" OC NEW 2X105 • 16" OC SISTERED TO EXIST 2x6'5 i EXIST. STAIR u;IELIc _ EXI8T2X6 CLG JOIST • 16" OC NEW 2)VO'S • 16" OC SISTERED TO EXIST 2X6'8 NEW 2X10 EXISTING 2X6 CLG JOIST FLOORING UPPER FLOOR FRAMING FLAN DETAIL 3/15 P.LAM BEAM r - P1.C2 -5053 -CRIPPLE - C CONC PR -L t EPDX-' GRO-.T EA. END OF 1+0R; r , 2X3 FLASHING 2X BLOCKING DECKING - 2X6 WALL 2X8 DECK JOIST TAPERED 2X SOLID RIM JOIST WNW 4. PLWD SHTG JOSS - 0 BEAR Ch EXI WA-. EXISTING STEM WALL 4 •5 DRILL t EPDXY !sROUT._ - 8" INTO FOOTING TO EXTEND INTO NE L CONC.. SLAB DETAIL 3/C - PLLD ) FAME WALL =�I2. S.+'3 7 .-2X SOLID BLKG SHTG y , 2X JOIST 1 1 -EXIST aRA'''E WALL - - I EXISTING 4" CONC. SLAB 1 SIMPSON T5 STRAP j z - i: :::RaJND DOWN ARC- COLUMNS 'v SIMPSON C1366 DRILLED I GRO:.ITED I / •3 X I_ TES 3 • 2" 00 ALL THREAD ANCHOR ,,,,,,•3 TOP t REMA'NING • 4' OC C -� 4" SLAB ,—FIN. GRADE SEE °LAN NEW 3'8" X 3'8" X 10" TWIG, FTG. W/ (3) •6'S EA. WAY UNDER EXIST. FTG, EXISTING FOOTING 2'8" X 28" X 10" TI-K. r L EXISTING CONC. FTG. -14.1 s on / f10'/ / REFER TO FOOTINGS AND FOUNDATION PLAN FOR SIZE 4 RENF. X 10" PIER W/(4) • 4'5 X 6 VERT• ST :»I TYP. MICRO-LAM 5 C'.0 ■ERE OCCUR) 5 1/4 X 9 :sL.L.E - LAM B1 (2) P5120 W /8EA. '/2' MB 2'6" X 2'6" X 10" THICK FTG. W/ (3) •4 EA WAY 10" X 10" PIER W/ (4) •48 VERT, • - -- -r- - — NEW 4" CONC. SLAB \ W/ • 5 • 3' OC EA. WAY I (SEE DETAIL 3 /C) a . _.1__, k LINE OF BEAMS ABOVE -- PLWD fr G DETAIL 3/A EXISTING 20" FOOTING EXISTING FOOTING 2 X 2'511 X 10" TI-1K. s n L W/ 8" x 24 STEM WALL - -r FOOTINGS AND FOUNDATION THIRD FLOOR ROOF FRAMING - TRuSSE.S v I EXISTING 4" CONC. SLAB W fr APPROAD MA's 1 4 2002 10 *mil /' , d 141. SE" 'Rt.55E8 OC (1 4X6 4DR SCALE DATE d 1 � �a 0— dra 1/4 • 1 GLUE LAM TO EXTEND 6' INTO WALL, NOTCHED FOR 2X6 TOP °LATE. TOP PLATE TO BE NAILED (2) 16d SINKER NAILS 4 6" 00 ALLEN JOINANNE55EN 1393056TH PL 5. TUKWILA, WA. 98168 DETAIL 3/D 206- 246 -5511 HOME PHONE 206- 248 -8968 FAX KITC 4EN ADDITION FRAMING —141P SET TRUSSES •24" OC RECEIVED CITY OF TUKWILA C`ps APR 19 2002 PERMIT CENTER 4, PAGE 3 p