HomeMy WebLinkAboutPermit D02-051 - FOSTER HEIGHTS - LOT 154 Foster Heights D02-051 Lot 15 4806 S 145 St City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2610000150 Address: 4806 S 145 ST TUKW Suite No: Tenant: Name: FOSTER HEIGHTS - LOT 15 Address: 4806 S 145 ST, TUKWILA, WA Owner: Name: TRIDOR INC Address: 2226 ELLIOTT AV, SUITE A, SEATTLE WA Contact Person: Name: CHARLES PRIB Address: 14205 SE 255 PL, KENT, WA Contractor: Name: LONG CLASSIC HOMES, LTD. Address: 1624 PIONEER ST, ENUMCLAW, WA Contractor License No: LONGCHL05409 DESCRIPTION OF WORK: CONSTRUCTION OF A NEW 2,360 SQ FT SINGLE FAMILY RESIDENCE, 400 SQ FT ATTACHED GARAGE AND 90 SQ FT COVERED DECK AREA. PUBLIC WORKS ACTIVITIES INCLUDE: access, land altering and storm drainage. PER CONDITION OF FINAL PLAT L2000 -026 THE RESIDENCE SHALL BE PROVIDED WITH A SPRINKLER SYSTEM PER NOTE 12 SHT 2 OF 3 OF RECORDED PLAT. PROJECT ON VALVUE SEWER AND WATER DISTRICT #125 WATER. Value of Construction: $224,358.40 Fees Collected: $2,958.69 Type of Fire Protection: N/A Uniform Building Code Edition: 1997 Type of Construction: V -N Occupancy per UBC: 7 Public Works Activities: Curb Cut/Access /Sidewalk/CSS: Y Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: Y Volumes: Cut 142 c.y. Fill 142 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: Y Street Use: N Water Main Extension: N doe: Devperm DEVELOPMENT PERMIT D02 -051 Private: Private: Permit Number: D02 -051 Issue Date: 05/02/2002 Permit Expires On: 10/29/2002 Phone: 206 - 443 -7735 Phone: 253 631 -6864 Phone: Expiration Date: 11/01/2002 Public: Public: Printed: 05 -02 -2002 z cc 2 w . 6 00 U 0 LLI WI CD Li_ . w 0 u_a I . I- _ Z t-- Z F- 11J ui U c O N a1- w W U .• Z -I 0~ z Water Meter: Channelization / Striping: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 ** Continued Next Page ** D02 -051 Printed: 05 -02 -2002 Permit Center Authorized Signature: Signature: Print Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructioyf car the erformanc of work. I am authorized to sign and obtain this development permit. ( D02 -051 Date: d This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 05 -02 -2002 Parcel No.: 2610000150 Address: 4806 S 145 ST TUKW Suite No: Tenant: FOSTER HEIGHTS - LOT 15 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All mechanical work shall be under separate permit issued by the City of Tukwila. 6: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 7: Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 8: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 9: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 10: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 11: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 12: There shall be no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building Inspector. 13: ** *PUBLIC WORKS DEPARTMENT * ** 14: The applicant must notify the City Utility Inspector at (206)433 -0179 upon commencement and completion of work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. RESIDENCE ON LOT 15 SHALL BE SPRINKLED; REFER TO NOTE 12 OF ON SHEET 2 OF 3 OF RECORDED PLAT L2000 -026. APPLICANT SHALL CONTACT TUKWILA FIRE DEPARTMENT FOR COORDINATION. PRIOR TO FINAL PERMIT SIGNG -OFF APPLICANT SHALL PROVIDE A RECORDED COPY OF EASEMENT AND MAINTENANCE AGREEMENT FOR ROCKERY WITH ASSOCIATED DRAINAGE ON LOT 14. 15: The City of Tukwila has an undergrounding ordinance requiring the power, telecommunications, and cable service lines be underground from the point of connection on the pole to the house. doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS D02 -051 Permit Number: D02 -051 Status: ISSUED Applied Date: 02/26/2002 Issue Date: 05/02/2002 Printed: 05 -02 -2002 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 16: Any material spilled onto any street shall be cleaned up immediately. 17: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off -site or into existing drainage facilities. 18: The Land Altering Permit Fee is based upon an estimated 142 cubic yards of CUT and 142 cubic yards of FILL. If the final quantity exceeds this amount, the developer shall be required to recalculate the final quantity and pay the difference in permit fee prior to the Final Inspection. 19: From October 1 through April 30, cover any slopes and stockpiles that are 3H:1V or steeper and have a vertical rise of 10 feet or more and will be unworked for greater than 12 hours. During this time period, cover or mulch other disturbed areas, if they will be unworked more than 2 days. Covered material must be stockpiled on site at the beginning of this period. Inspect and maintain this stabilization weekly and immediately before, during and following storms. 20: From May 1 through September 30, inspect and maintain temporary erosion prevention and sediment at least monthly. All disturbed areas of the site shall be permanently stabilized prior to final construction approval. 21: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. 22: Applicant shall follow all the conditions of Final Plat L2000 -026 and comply with Geotechnical report prepared by Geospectrum Consultants, Inc. dated Feb. 10, 1998. Geotechnical Engineer shall observe the implementation of the approved SFR plans during construction. Field reports are to be submitted to Public Works in a timely manner and shall include: a) Temporary Erosion Control and Excavations b) Implementations of footings, foundations, retaining walls, driveway placement and associated drainage system and placement of backfi I I. Prior to final permit signoff, the Geotechnical Engineer is to provide certification on a lot by lot basis that the work has been accomplished in accordance with Geotechnical recommendations - refer to Feb. 1, 1998, Geotechnical Evaluation prepared by Geospectrum Consultants, Inc., P.O. Box 276, Issaquah, WA 98027 -0276, Phone No. (425)391 -4228. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions • C- pf;‘,43 D02 -051 Date: Printed: 05 -02 -2002 Project Name/Tenant: Value of Cons iicjionn; Site Address: State /Zip: Tax Ptcgplubb 4/ 6 0 Property Owner: O sq. ft. Garage /Carport sq. ft. Accessory Structure(s) sq. ft. Uncovered Deck Phone: Street Addres • City State /Zip: Contractor: _ Phone: Street Address: City State /Zip: Fax II: r u Architect: Engineer: AGO- Phone: Street Address Cit State /Zip: Contact Person: Description of work to be done: Type of work: New Single - Family Residence ❑ Addition - Single - Family Residence in Interior Remodel- Single- Family Residence ❑ Residential Accessory Structure* ❑ Remodel /Addition to Accessory Structure ❑ Garage(s) ❑ Deck(s) - Covered & Uncovered ❑ Residential Reroof Is this site served by: ❑ Sewer ❑ Septic (King County Health Dept. approval required - 296 -4722) Existing Square Footage for Structure: sq. ft. Dwelling sq. ft. Covered Deck(s) sq. ft. Garage /Carport sq. ft. Accessory Structure(s) sq. ft. Uncovered Deck 2��, Propos New Square Footage: 7iii�i sq. ft. Dwelling 'z7 sq. ft. Covered Deck(s) O sq. ft. Garage /Carport sq. ft. Accessory Structure(s) sq. ft. Uncovered Deck Floor Area Ratio: (total floor area of all structures divided by the area of the - 3 2 r:2' c7 /7.7 *For an Accessory dwelling, provide the following: Lot area Floor area of principal dwelling Floor area of accessory dwelling ` Provide documentation that shows the principal owner lives in one of the dwellings as his or her primary residence. CITY OF TU'WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 FOR STAFF USE ONLY Project , . mber: Permit Number: 71)0,- 1 C c Q 3 Single - Family Residential Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews shall be determined by the Public Works Department) ❑ Channelization /Striping Curb cut /Access /Sidewalk ❑ Fire Loop/Hydrant (main to vault) #: Size(s): ❑ Flood Control Zone Hauling % Land Altering: 0 Cut 142.. cubic yds. 0 Fill 142 cubic yds. ❑ Moving an Oversized Load: Start Time: End Time: ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public X Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be re- viewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall ex- pire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Application taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM SFPERMIT.DOC 2/13/97 - A rl - S 1 E I •E• MIT APPLICAT ONS MUST BE SUBMITTED WITH THE FOLLOWING: • DRAWINGS PREPARED BY A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER MAY BE REQUIRED BY THE BUILDING OFFICIAL ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Copy of recorded Legal Description from King County ❑ ❑ Certificate of water /fire flow availability (Form H -11 a). Contact the Public Works Department (206) 433 -0179 for servicing district. rl Certificate of sewer availability (Form H -11). Contact the Public Works Department (206) 433- 0179 for servicing district. ❑ ❑ Metro: Residential Sewer Certification (if Tukwila Sewer District) (Form H -12) ❑ ❑ King County Health Department approval for septic - 296 -4722 Four (4) sets of working drawings, which include: ❑ ❑ Site Plan (see example Form H -16) 1. Existing fire hydrant location(s). 2. Proposed access road. 3. Driveway location- driveway shall be 10' wide minimum and 20' wide maximum. If driveway is over • 150' long, driveway shall be 20' wide and have an approved turnaround (City Ordinance 1741). 4. North arrow and scale. 5. Building setback from property lines. Any proposed or existing easements must be shown on plan. 6. Public Works review requires the following on site plan: driveway location (10' min., 20' max. width), show proposed and existing power, water and sewer lines, existing storm drainage system, downspouts and foundation drains, and where drains tie -in. 7. Parking plan. 8. Lowest building elevation (if in Flood Control Zone). 9. Estimated /proposed topography at 2' intervals and proposed elevation of lowest floor level. 10. Identify location of sensitive areas slopes 20% or greater, wetlands, watercourses and their buffers. 11. Identify location and size of significant trees that are located in sensitive areas and buffers or the shoreline zone. Of those, identify which are to be removed (Title 18, City of Tukwila Zoning Code). 12. Identify location of high water mark of the Green /Duwamish River if site is located within 200' of the high water mark. 13. See Public Works Checklist for detailed site plan information required for Public Works Review (Form H -9). ❑ ❑ Foundation plan and details ❑ ❑ Floor plan ❑ ❑ Roof plan ❑ ❑ Building elevations (all views) ❑ ❑ Building height ❑ ❑ Building cross - section ❑ ❑ Structural framing plans and details necessary to completely describe construction ❑ ❑ Washington State Energy Code Data (Gas /Electric /Oil /Propane /Heat Pump) Form H -15 available at Permit Center OR Prescriptive Heating System Sizing Chap 9 Form H -6. ❑ ❑ Complete Land Use Applications if not previously submitted (i.e., Reasonable Use Exception, Variance, Shoreline or Tree Permit). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance and other land use or SEPA decisions. ❑ ❑ If dwelling has a septic tank, and a bedroom or bathroom are added, provide written approval from the King County Health Department or the Tukwila Public Works Department prior to submittal of permit application. ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED A LENT: Signature: Print name: - - � � / 4'5 Address . S� gg SFPERMIT.DOC 2/13/97 bee. 636-6.0v cit $i , /e/i4:2 ¢Z r Date: Fax It: turttn t.nt,v�. Payee: ACCOUNT ITEM LIST: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 LONG CLASSIC HOMES Current Pmts Amount BUILDING - RES INSP FEE - STORM DRAIN INSP FEE - UTILITY LAND ALTERING PERMIT FEE LAND ALTERING PLAN CHECK PLAN CHECK - RES PLAN CHECK - UTILITY STATE BUILDING SURCHARGE 000/322.100 412/342.400 000/342.400 000/322.100 000/345.830 000/345.830 000/345.830 000/386.904 1, 693.75 15.00 15.00 72.00 37.50 91.00 20.00 4.50 M , RECEIPT ' 1W re 6D Parcel No.: 2610000150 Permit Number: D02 -051 U O Address: 4806 S 145 ST TUKW Status: APPROVED 0 0 Suite No: Applied Date: 02/26/2002 W I Applicant: FOSTER HEIGHTS - LOT 15 Issue Date: to u_ W 0 . Receipt No.: R020000584 Payment Amount: 1,948.75 g 5 Initials: SKS Payment Date: 05/02/2002 12:31 PM = • a User ID: 1165 Balance: $0.00 i~ _ Z F. I- O Z I- LL! U 0 O N TRANSACTION LIST: 01— Type Method Description = U F- F- — O Payment Check 582 1,948.75 III co U C O . Z Description Account Code Total: 1,948.75 To'r ` 20.1.9 Printed: 05 -02 -2002 4 ACCOUNT ITEM LIST: doc: Receipt City of Tukwila Current Pmts PLAN CHECK - RES 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 z RECEIPT ' 1- Z W 6 -J U : Parcel No.: 2610000150 Permit Number: D02 -051 U 0 Address: 4806 S 145 ST TUKW Status: PENDING . N w Suite No: Applied Date: 02/26/2002 i H Appl icant: FOSTER HEIGHTS- LOT 15 Issue Date: co u_ w 2 QQ Receipt No.: R020000264 Payment Amount: 1,009.94 LL Q Initials: SKS Payment Date: 02/26/2002 10:24 AM Z W User ID: 1165 Balance: $1,553.75 Z 1Z- 1— O' Z 1— Payee: LONG CLASSIC HOMES g D DC3 O — TRANSACTION LIST: W H ill Type Method Description = U Amount 1-- - O. Payment Check 572 1,009.94 L jj Z N. U = . ~ O F- Z Description Account Code 000/345.830 1,009.94 Total: 1,009.94 42 2 3 02/26 97.16 TOTAL. 2.09%68 Printed: 02 -26 -2002 COMMENTS: Traw,i1 -- G pP r0V -r 1 O Z.\ h r, O pn r(V ed Date Called: la - 0 1 3 -vr3, T - 100vs T r cJ A- tor QopVnVeo M( Date Wanted: 1 � 44 -)- 3 -o2 I 1nGt\ - '?Pirvinl4 (Orvi -e4 ( v__ —\_. t r,„, Project: �O� P r A.\ nlc i�}S I Type of Inspectioq 1 VCI rl CA) c Address: () ( S ) L- 15 - SA, Date Called: la - 0 1 3 -vr3, Special Instructions: Date Wanted: 1 � 44 -)- 3 -o2 a.m. p.m. Requester: Phone No: .`4 EOM 'iiux;Nlaniy sty; ,sa.F:a.''.i ,not : PERMIT N' I CITY OF TUKWILA BUILDING DIVISION �'' INSPECTION NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 - Approved per applicable codes. INSPECTION RECc ) Retain a copy with permit Corrections required prior to approval. lnspecto . c. Date: E1 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1 Project: 1: - Type of Inspection: ` ti V Address: k _ `t i a Iti I Date Called: 1 � 2 CQ, / Special Instructions: Date Wanted: ` If a.m. p.m. Requester: ;• Phone o: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 EI Approved per applicable codes. INSPECTION RECO) Retain a copy with permit PERMIT NO. D Corrections required prior to approval. OMMENTS: VZ /ate J v Z. PLA■J- (kreiv t Inspector: C� U Date: 1/u/ Z.1 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: t 2 / /6.U2 9 V Type of Inspectiop r ca Addres : 12l) 6/02- I-1V ,S e_af r,H ML/ e k...),241 Nri -J`A 1 k 0 / .2.e -j, : ,,: .• - AU 7i ( Gh.ivt44, a ir PP-1/4702_ it). -1 Ali y G 'S anti Date wanted: � 1 � a.m 1 4th Z /Lad 40 6 at f/ e44, 7 C niter► /14c any / Project: , n A4 c Type of Inspectiop r ca Addres : Date called: /Li) c» Special instructions: `'� Date wanted: � 1 � a.m Requester: /j Phone: 606 C > INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila WA 98188 n Approved per applicable codes. INSPECTION RECOO Retain a copy with permit PERMIT NO. (206)431 -3670 El Corrections required prior to approval. Inspector: kk) $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pro a t: { 0 Type of Inspection: 0 v j 4 Address: Date called: i 7/ O 2- Special instructions: L i c + Date wanted: / V67 a.m. I L�) p.m. Requester: // Phone: ,� - 1 , &, no?? mcax.. �nh ;naDif[s�;tL INSPECTION NO. INSPECTION RECO Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter B lvd, #100, Tukwila, WA 98188 0 Approved per applicable codes. s a - • f) 0 0 2 . -0 51 PERMIT NO. (206)431 -3670 0 Corrections required prior to approval. COMMENTS: V oS 2) 7A4A) ca.Q-1 Inspector: Date: 40 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Z W re J U 00 1 0 w IL LL W O 2 gQ to = Z � W W U� c 0 t--. W H u. Z al co z 5 kr: /Ie Type of Irispecti _2h/ /1 41 2 `°' Add N 5 1 f Date Ca led: 7 / 6 S tecial Instructions: Date Wanted: anted: /O 1 U2. a, Requester l Gu! Phorip14 6ao ...0387Q INSPECTION NO. INSPECTION. REC Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION \" (206)431 -3670 jVi 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. ,]Cb?-65/ Corrections required prior to approval. COMMENTS: " / A er-= Date: / _i,° - c2 7.00 REINSPECTION EE'REQUIRED. Pr to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. all to schedule reinspection. pt No. f R ei Date: Project: ,Z i rr;e /Ve7c5./vrS Jo 7 ,.. 4,S— Type of In j spe tion: �^ /! ,/G /k/" -- - ��.- • of c. Addr ss: J /S/S .$ 1` Date Called,: /4 - /-oz. . Special Instructions: L- c{�/1J�- 'rte - { J � Date Wanted: ��� ^� a.m., p.m. Requester hh Phone No: 253 e.:46 • INSPECTION RECD,„ Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Fr Corrections required prior to approval. COMMENTS: L -; CA pP(C9Vf(D A 4 - y, v.e, CO rei6-0.—. MQS$er hoc( o0 ' r C CAA) c, w v\ tif+ ra v rer rPw\ pv11 - S V' l'A r 1 rn i1 V" \-P 1 r, (loc. vl i p.C, 04 Inspector: \ Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 1300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: :7; 'I, . 'il;k$4;!,k4C4 COMMENTS: Type of-Inspection: /r l /A/c Add ess: Date Call xb,... Special Instructions: Date Wanted } a.rti. • Requeste . (GcC Phone No: 5 G-e6 f 03 3 ' INSPECTION REC D,,.. Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER gNO i (216)431-3670 pproved per applicable codes. El Corrections required prior to approval. Inspector: Date: 9 30 _ G E] $47.00 REINSPECTION FEE REQUIRED. Prior to inspect'on, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: Special Instructions: Date W . . INSPECTION NO. INSPECTION RECO) Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 Approved per applicable codes. (206)431 l:_ Corrections required prior to approval. Date* .00 REINSPECTION F REQUIRED. Pr19i to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. all to schedule reinspection. Receipt No.: Date: COM MENTS: Type of Inspection: Date Called: / Special Instructions: Date Wanted: a.m. Requester: ;; Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION :6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECO) Retain a copy with permit 47.00 REINSPECT! O'N FEE REQUIRE paid at b300 Southcenter Blvd., Suite 100. Ca Receipt No.: PER (206)431 -3670 Corrections required prior to approval. Date: 9— 2 G'd D. P for to inspection, fee must be I to schedule reinspection. Special Instructions: Requester: . INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECD Retain a copy with permit (206)431 -3670 pproved per applicable codes. Corrections required prior to approval. COMMENTS: 7.00 REINSPECTION FE REQUIRED. Prioq'to inspection, fee must be p id att300 Southcenter Blvd., Suite 100. all to schedule reinspection. Project: Type of Inspection: Date Called: Special Instructions: Date Wanted: Requester: Phone No: rmi INSPECTION RE Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 pproved per applicable codes. El Corrections required prior to approval. COMMENTS: Date: 4 .00 REINSPECTIO FEE REQUIRED. Pr or to inspection, fee must be p d at t 300 Southcen er Blvd., Suite 100. Call to schedule reinspection. eipt No.: Project: Type of Inspection: Date Called: �� az Special Instructions:, Date Wanted: Phone No , INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved, per. applicable codes. INSPECTION RECti Retain a copy with permit A00-4 T O. 06)431 -3670 Corrections required prior to approval. COMMENTS: $47.00 REINSPECTI9 FEE REQUIRED. Prior to inspection, fee must be paid at t300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Address: Date cal ed: 7 /0 2 Special instructions: Date wanted INSPE ION NO. INSPECTION RECOR Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. $4 .00 REINSPECTION REQUIRED. Prior • inspection, fee must be paid 6300 Southcenter Blvd., ite 100. Call to s edule reinspection. Receipt No: Project: Type of Inspection: 5+ rm drain h ookup Address: 206 s 1454h St Date called: Special instructions: d ot 5 Date wanted: ff a.m. Requester: . Ira iou5er Phone: 206 -793 - -3d. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 0 Approved per applicable codes. n Corrections required prior to approval. COMMENTS: Inspector: Date:.. / 11 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • Project: downspouT d rain Address: , 4240 6 S / 46 Special instructions: Date wanted: 1:: Requester: .. . Phone: , INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd, #100tukwila,,WA 98188 DO2— 05/ PERMIT NO. (206)431-3670 n Approved per applicable codes... LI Corrections required prior to approval. COMMENTS: • [1] $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Type of Inspection: Address: 4goo s.(4 si Special instructions: Date wanted: a.m. Requester, Phone: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 'Approved per applicable codes. COMMENTS: 47.00 REINSPECTION FEE ' EQUIRED. Prior to i p: ction, fee must be paid at 6300 Southcenter Blvd., Su e 100. Call to schedu : reinspection. INSPECTION REC Retain a copy with permit Corrections required prior to approval. PERMIT NO. )CI (206)431 -3670 Ad ress: L Date lie? Special instructions: Date wanted: Requester. 7 4- Phone: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 COMMENTS: Approved per applicable codes. INSPECTION RECOR Retain a copy with permit Corrections required prior to approval. El $47.00 REINSPE ON FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: PERMIT NO. (206)431 -3670 INSPECTION REC Retain a copy with pe INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: $47.00 REINSPECTION FEE REQUIRED. Prior to.inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Type of Inspection: Date called: Special instructions: Date wanted:" Requester: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION RE Retain a copy with permit (4' '. : tiMu.' 2tl v:S iC "5.�'t+ t'o:.'aa.'tl ".rya a`SCG is *,.''271aq t.w;4dG i it:�i.: . PERMIT NO. (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: El $47.00 REINSPEC � , N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Fire Department Thomas R Keefe, Fire Chief ' Project Name FOS 1 er Pei (. 4 / 4 '. L/ J( AddreSs. Retain current inspection schedule Needs shift inspection X Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: FINALAPP.FRM Authorized Signature TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Steven M. Mullet, Mayor Permit No. D 02- 05 Suite # / 2. Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206•575-4404 • Fax: 206-575-4439 Sent by: Earth Consultants Dear Ms. Spencer: April 3, 2002 E -9920 City of Tukwila Department of Community Development 6300 South Center Boulevard, Suite 100 Tukwila, Washington 98188 Attention: Ms. Joanna Spencer, Development Engineer Subject: Geotechnical Review — Lot 15 Proposed Foster Heights Subdivision Residences South 146 Street and 51" Avenue South Tukwila, Washington Reference: Geospectrum Consultants, Inc. Geotechnical Evaluation Foster Heights Plat Development Tukwila, Washington Revised Drawing FH -15 Site, Utility, and Drainage Plan Dated March 22, 2002 425 746 0860; 04/03/0 % --- 3:55PM;JetFax #59;;Pagc.2 /3 Earth Consultants Inc. (AYrt(t1U%<a11I CA%)klgi is & I :11\'Ir is ti iti.d tilyr'��IL11ti In accordance with your request, Earth Consultants, Inc. (ECI) has reviewed the referenced drainage plan and revisions for Lot 15 (revised March 22, 2002). At the request of Long Classic Homes, ECI has assumed the role of geotechnical engineer of record for the project. Based on our review of the revised plan, ECI is in agreement with the geotechnical aspects of the revised plan. ,pot -psi 1805. 136tn Race N.E., Suite 201, Bellevue, Washington 98005 Bellevue (425) 643.3780 FAX (425) 746 -0860 Toli Free (888) 739.6670 Sent by: Earth Consultants City of Tukwila April 3, 2002 We trust this information meets the geotechnical plan review requirements for Lot 15. If additional information is required, please call. Respectfully submitted, EARTH CONSULTANTS, INC. Raymond A. Coglas, P.E. Project Manager ! FxvMFs 7 / Z RAC /jme cc:. Long Classic Homes Attention: Mr. Doug Pulley 425 746 0860; 04/03/02_..,3: 55PM; JetFnx #591 ;Page 3/3 Earth Consultants, Inc. City of Tukwila Department of Community Development 6300 South Center Boulevard, Suite 100 Tukwila, Washington 98188 Subject: Drawing FH -15 Site, Utility, and Drainage Plan Foster Heights, Lot 15 RECEIVED APR 1 0 2002 TUKW 1LA PUBLIC WORKS Attention: Ms. Joanna Spencer, Development Engineer Geotechnical Review - Lot 15 Proposed f=oster Heights Subdivision Residences South 146 Street and 51' Avenue South King County, Washington Eai rh Consultants Inc. Geotechnical Engineers, Geologists & Environmental Scientists January 11, 2002 E -9920 Reference: Geotechnical Evaluation o Foster Heights Plat Development ° i Geospectrum Consultants, Inc., dated February 10, 1998 0 Dear Ms. Spencer: In accordance with your request, Earth Consultants, Inc. (ECI) has reviewed the referenced geotechnical engineering study and drainage plan for Lot 15. At the request of Long Classic Homes, ECI has assumed the role of geotechnical engineer of record for the project. Based on our review, ECI is in agreement with the geotechnical and drainage recommendations for Lot 15. CORRECTION LTR #._ P Do- o5( RECEIVED CITY OF TUKWILA APR 0 8 2002 PERMIT CENTER 1805 - 136th Place N.E., Suite 201, Bellevue, Washington 98005 Bellevue (425) 643-3780 FAX (425) 746 -0860 Toll Free (888) 739-6670 City of Tukwila January 11, 2002 We trust this information meets the geotechnical plan review requirements for Lot 15. If additional information is required, please call. Respectfully submitted, EARTH CONSULTANTS, INC. Raymond A. Coglas, P.E. Project Manager RAC /jme cc: Long Classic Homes Attention: Mr. Doug Pulley 1 EXPIRES ^7 Earth Consultants, Inc. 0Z E -9920 Page 2 20021113001812 DOCUMENT TITLE: Maintenance Agreement REFERENCE NUMBER(S): None GRANTOR(S): Long Classic Homes, Ltd. GRANTEE(S): Long Classic Homes, Ltd. LEGAL DESCRIPTION: Portions of Lots 1 -9, 14-16, Foster Heights, according to the plat recorded in Volume 200 of Plats at pages 89 through 91 ASSESSOR'S PROPERTY TAX PARCEUACCOUNT NO. After recording return to: Mr. David S. Kerruish 7016 — 35 Avenue NE Seattle, Washington 98115 -5917 File No. 105.020 MAINTENANCE AGREEMENT - 1 20021113001812 LONG AG 23.66 PAGE 661 OF 665 11/13/2602 14:26 KING COUNTY, WA MAINTENANCE AGREEMENT Lot 2 is benefited by an easement imposed upon Lot 1; Lot 3 is benefited by an easement imposed upon Lot 2; Lot 4 is benefited by an easement imposed upon Lot 3; Lot 5 is benefited by an easement imposed upon Lot 6; Lot 6 is benefited by an easement imposed upon Lot 7; Lot 7 is benefited by an easement imposed upon Lot 8; JOc OSI I I� flThLE 1 The undersigned owner of the property herein described does impose as an easement and covenant running with the land an obligation upon the owners and future owners of the Benefited Property (as described herein) to maintain drainage improvements located within easements imposed upon the Burdened Property (as described herein), as provided in this instrument. 1. Ownership of Property. The property which is subject to the provisions of this instrument is owned by Long Classic Homes, Ltd., and is legally described as follows: Lots 1 -9, and Lots 14 -16, in Volume 200 of Plats, Pages 89 through 91 inclusive, situate in King County, State of Washington. 2. Benefited and Burdened Properties. The following Lots are benefited by an easement recorded on an adjacent Lot: NOV 1 3 Z[!!J/ � ui�LVILp PUBLIC WORKS z • 6 J U U 0 W = CO LL wO <L Q U� = a � w Z = t-- I- W uj U � O T. O H L f-� r' - O w z U (I) O F. z g. Lot 8 is benefited by an easement imposed upon Lot 9; h. Lot 15 is benefited by an easement imposed upon Lot 14; i. Lot 16 is benefited by an easement imposed upon Lot 15. Each Lot for which there is a right to use an adjacent Lot is hereafter referred to as the "Benefited Property" with respect to the right to use the easement located on the adjacent Lot. Each Lot that has imposed upon it an easement in favor of an adjacent lot is referred to as the "Burdened Property" with respect to the easement imposed upon the Lot. A Lot may be both burdened and benefited, by different easements. The easements described herein are recorded at King County Recorder's No. , and were granted for the purpose of providing drainage for the Benefited Properties. 3. Duty to Maintain Easement and Improvements. The Owner of each Benefited Property shall have the duty and obligation to maintain the easement established for the benefit of the Benefited Property, and all drainage improvements located within its easement, in a manner that preserves the function and utility of the drainage improvements within the easement and in full compliance with all applicable laws and building or zoning codes. The Owner of the Benefited Property may not construct, place or maintain any other structures in its easement, except the drainage improvements, and may not engage in any activity in the Easement that may damage the improvements located on the Burdened Property. The Owner of the Burdened Property may not place any improvements, or engage in any activities, that materially interfere with the function or utility of the drainage improvements located within the easement. Notwithstanding the prohibition upon the placement of structures in the easement, the owner of the Burdened Property may place a fence within the easement (as long as the fence does not damage or interfere with the drainage improvements in the easement), but such fence shall be repaired or replaced at the cost of the Owner of the Burdened Property if the fence must be removed in order for the Owner of the Benefited Property to maintain the drainage improvements within the easement. 4. Access. The Owner of the Benefited Property shall have whatever right of access through the Burdened Property to construct, repair, maintain and replace drainage improvements located in the easement, and to exercise the rights granted by this easement. The Owner of the Benefited Property shall compensate the Owner of the Burdened Property for any damages to the easement or to the Burdened Property and its improvements that are caused by Owner of the Benefited Property or the Owner's agents. The Owner of the Burdened Property shall compensate the Owner of the Benefited Property for any damages to the improvements located in the easement that are caused by the Owner of the Burdened Property or the Owner's agents. 5. Indemnity. The Owner of the Benefited Property agrees to indemnify, defend and hold the owner of the Burdened Property harmless from all losses, damages, claims, obligations, liabilities and expenses (and all actions, proceedings, judgments, attorney's fees and costs incident thereto) related to the Owner of the Benefited Property's use of the easement, or the improvements located therein. 6. Compliance with Laws. All improvements, installations and work to be MAINTENANCE AGREEMENT - 2 constructed or performed pursuant to this agreement, including, without limitation, the installation, maintenance and repair of the improvements, shall be constructed and performed in compliance with all laws, ordinances, orders, rules, regulations and requirements of any governmental entity having jurisdiction over the easement. 7. Enforcement. This Agreement shall be governed by and construed in accordance with the laws of Washington. In the event of any controversy, claim or dispute between the parties effecting or relating to the subject matter or performance of this Agreement, the prevailing party shall be entitled to recover from the nonprevailing party all of its reasonable arbitration and litigation expenses, reasonable attorneys' fees, accountant's fees, expert witness fees and costs, on all issues of municipal, county, state, federal and bankruptcy law. If any provision of this Agreement is determined by a court of competent jurisdiction to be invalid or unenforceable, the remainder of this Easement shall remain in full force and effect. 8. Successors and Assigns. The rights and obligations of the parties shall inure to the benefit of and be binding upon their respective successors and assigns, and shall bind all invitees of Grantor. There is no restriction on the transfer of the parties' rights and/or duties under this Agreement. OWNER: LO G CLASSIC HOMES, LTD. By STATE OF WASHINGTON COUNTY OF PIERCE MAINTENANCE AGREEMENT -3 ss. I certify that I know or have satisfactory evidence that John M. Long is the person who appeared before me, and said person acknowledged that he was authorized to execute the instrument and acknowledged it as the President of Long Classic Homes, Ltd. to be the free and voluntary act of.such for the uses and purposes mentioned in this instrument. D TED: 2002 (L Renee M. Richardson (Printed name) Notary Public n � ? / My Appointment Expires: f1 � .�) N '.l z < z • w JU O 0 co 0 w • u_ u O • ¢ co I I- al Z = ZO • 1:3 O i • I- wW ..z Off' z PRIVATE DRAINAGE EASEMENTS LEGAL DESCRIPTIONS AN EASEMENT FOR DRAINAGE PURPOSES OVER THOSE PORTIONS OF LOTS WITHIN THE PLAT OF FOSTER HEIGHTS ACCORDING TO THE PLAT AS RECORDED IN VOLUME 200 OF PLATS, PAGES 89 TO 91, CITY OF TUKWILA, RECORDS OF KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: LOT 1- THE SOUTH 10 FEET THEREOF. TOGETHER WITH THE WESTERLY, NORTHERLY AND EASTERLY 5 FEET THEREOF. LOT 2 - THE SOUTH 10 FEET THEREOF. TOGETHER WITH THE WESTERLY, NORTHERLY AND EASTERLY 5 FEET THEREOF. LOT 3 - THE SOUTH 10 FEET THEREOF. TOGETHER WITH THE WESTERLY, NORTHERLY AND EASTERLY 5 FEET THEREOF. LOT 4 - THE WESTERLY, SOUTHWESTERLY AND SOUTHERLY 10 FEET THEREOF. TOGETHER WITH THE NORTH AND EAST 5 FEET THEREOF. LOT 5 - THE WESTERLY, NORTHWESTERLY AND NORTHERLY 10 FEET THEREOF. TOGETHER WITH EAST AND SOUTH 5 FEET THEREOF. LOT 6 - THE NORTH 10 FEET THEREOF. TOGETHER WITH THE WESTERLY, SOUTHERLY AND EASTERLY 5 FEET THEREOF. LOT 7 - THE NORTH 10 FEET THEREOF. TOGETHER WITH THE WESTERLY, SOUTHERLY AND EASTERLY 5 FEET THEREOF. LOT 8 - THE NORTH 10 FEET THEREOF. TOGETHER WITH THE WESTERLY, SOUTHERLY AND EASTERLY 5 FEET THEREOF. LOT 9 - THE NORTHERLY 10 FEET THEREOF. TOGETHER WITH THE EASTERLY 10 FEET OF THE NORTHERLY 40.07 FEET (AS MEASURED ALONG THE EAST LINE OF SAID LOT 9) THEREOF. TOGETHER WITH THE SOUTH 5 FEET THEREOF. TOGETHER WITH THE EASTERLY 5 FEET OF THE SOUTH 43.44 FEET (AS MEASURED ALONG THE EAST LINE OF SAID LOT 9) THEREOF. TOGETHER WITH THE WEST 10 FEET THEREOF. LOT 11 - THE WESTERLY 10 FEET THEREOF. TOGETHER WITH THE NORTH AND SOUTH 5 FEET THEREOF, LESS THE EAST 25 FEET THEREOF. TOGETHER WITH THE WEST 5 FEET OF THE EAST 30 FEET OF SAID LOT 11. z HZ -J U O 0 0 w • w J = H • LL w o u. W a = w I- _ z � I-- 0 z I- w U � O D- o 1-- w W I- - IL. O w z o O~ z LOT 12 – THE SOUTHWESTERLY 10 FEET THEREOF AS MEASURED RADIALLY FROM NORTHEASTERLY MARGIN OF THE CUL -DE -SAC FOR SOUTH 145 STREET. TOGETHER WITH THE EASTERLY, NORTHERLY AND WESTERLY 5 FEET THEREOF. il7 LOT 14 – THE SOUTHERLY 10 FEET AS MEASURED FROM THE NORTHERLY MARGIN OF SOUTH 145 STREET. TOGETHER WITH fY W NORTHEASTERLY, THE NORTHWESTERLY AND SOUTHWESTERLY .0,(9 5 FEET THEREOF. o o co 0 co LOT 15 – THE SOUTH 10 FEET THEREOF. TOGETHER WITH THE EASTERLY, 1 NORTHERLY AND WESTERLY 5 FEET THEREOF. N u- Wo al LOT 16 – THE SOUTHERLY, SOUTHWESTERLY AND WESTERLY 10 FEET "° THEREOF. TOGETHER WITH NORTHERLY AND EASTERLY 5 FEET LL Letter of Transmittal 3. 4. 21 ltra e.i.4 APR 2 3 2002 cows Uhl! TO: Long Classic Homes DElr;l 1624 Pioneer Street Enumclaw, Washington 98022 ATTENTION: Mr. Doug Pulley WE ARE SENDING YOU: ❑ Attached ❑ Under Separate Cover Via: THE FOLLOWING: El Field Reports ❑ Reports ❑ Preliminary Drafts El Test Results ® Per Your Request ❑ Copies 2 Date Description 4/18/02 Vapor Building Letter THESE ARE TRANSMITTED FOR YOUR: ® Information ❑ Files ® Approval ❑ Review and Comments ❑ Signature ❑ Distribution ❑ ❑ REMARKS: If you have any questions please call our office. cc: 1. City of Tukwila 2. Earth " on ultants Inc. Gcotechnic l Engineers, Ceolol:fists& Environmental scientists 1805 - 136' Place Northeast, Suite 201 Bellevue, Washington 98005 Phone: (425) 643 -3780 / Fax: (425) 746 -0860 Toll Free: 1- 888 - 739 -6670 DATE: April 18, 2002 JOB NO.: E -9920 PROJECT: Foster Heights Subdivision ATTN. Mr. Dave Larson BY Keri Bate Thank you! April 18, 2002 E -9920 Long Classic Homes 1624 Pioneer Street Enumclaw, Washington 98022 Attention: Mr. Doug Pulley Subject: Dear Mr. Pulley: In accordance with your request, Earth Consultants Inc. (ECI) has reviewed the use of the Rheo -Mix concrete additive for vapor protection of the building slabs. ECI is familiar with this product and its use on several of our commercial projects. The additive is produced by Cadman, and is intended as a substitute for a conventional vapor barrier. It is our understanding that the Rheo -Mix additive effectively reduces the porosity of the concrete, thereby inhibiting the transmission of water vapor through the slab. In our opinion, use of the Rheo -Mix is a suitable substitute for a conventional plastic sheeting vapor barrier. We trust this information meets your current needs. If you have any questions or need additional information, please contact us. Sincerely, EARTH CONSULTANTS, INC. Raymond A. Coglas, P.E. Project Manager cc: City of Tukwila Attn. Mr. Dave Larsen Vapor Barrier Building Slab -On -Grade Foster Heights Subdivision Tukwila, Washington EXPIRES? /7/ loos, L► ► iI 15 ► 0 Z Earth Consultants Inc. Geotechnical Engineers, Geologists & Environmental Scientists 1805 - 136th Place N.E,, Suite 201, Bellevue, Washington 98005 Bellevue (425) 643 -3780 FAX (425) 746 -0860 Toll Free (888) 739 -6670 Sent ,, by: Earth Consultants April 18, 2002 E -9920 Long Classic Homes 1624 Pioneer Street Enumclaw, Washington 98022 Attention: Mr. Doug Pulley Subject: Dear Mr. Pulley: In accordance with your request, Earth Consultants Inc. (ECI) has reviewed the use of the Rhea-Mix concrete additive for vapor protection of the building slabs. ECI is familiar with this product and its use on several of our commercial projects. The additive is produced by Cadman, and is intended as a substitute for a conventional vapor barrier. tt is our understanding that the Rheo -Mix additive effectively reduces the porosity of the concrete, thereby inhibiting the transmission of water vapor through the slab. In our opinion, use of the Rheo -Mix is a suitable substitute for a conventional plastic sheeting vapor barrier. We trust this information meets your current needs. If you have any questions or need additional information, please contact us. Sincerely, EARTH CONSULTANTS, INC. Raymond A. Coglas, P.E. Project Manager cc: City of Tukwila Attn. Mr. Dave Larsen 425 746 0860; Vapor Barrier Building Slab -On -Grade Foster Heights Subdivision Tukwila, Washington EXPIRES'. /V)/ U0 Z 04/18/02 11 :52AM;Jetfax #8; Page 2/2 Earth Consultants Inc. r iir*II ,µirirrr•.+.(;rot.ry(I t &fawIrt it lirrintl In vir,l. It 10 1805. 136th Place N.E . Suite 201, Bellevue, Washington 98005 Bellevue (4 ?5) 643.3780 FAX (425) 746-0860 Tol; Free (888) 739.6670 z ~w J0 O 0 U) 0 w i J w g • -J u a = a LLI z1.- 1- 0 Z ~ o • U 0 w w u- 0 w z O N H 0 1- z - ' GEOSPECTRUIi/1 CONSULTANTS, INC. Gec c%,r7/ c./ rig' arc/ Eartf - , ScI February 10, 1998 Mr. Richard Schroeder Happy Valley Land Company P.O. Box 1324 Issaquah, WA 98027 Dear Dick, h,.jG�n�. �••�,, .1 „ 7. 4... .. Subject: GEOTECHNICAL EVALUATION Proposed 16 -Lot Foster Heights Plat Development South 146th Street & 51st Avenue South Tukwila, Washington Project No. 98- 103 -01 (-. __I FILE COPS This report presents the results of our geotechnical investigation performed on the site of the proposed Foster Heights residential development. The purpose of the investigation was to provide geotechnical engineering evaluations of the site conditions and geotechnical recommendations for site grading including optimum timing of site grading and general recommendations for site development. A preliminary plat map prepared by Baima & Holmberg, Inc. dated 9/12/97 was provided to us and used as a reference for our site explorations and our evaluations and recommendations. Based on the referenced plat map shown in Figure 2, the proposed plat includes 16 lots within the subject property. Access to lots 1 -14 will be provided by new cul- de -sac streets (Road A and Road B) which will join South 146th Street at the southwest corner of the property. from 240th. Lots 15 and 16 will be accessed directly from 51st Avenue South. Although no site grading exists at this time is expected that cuts and fills of only about 5 to 10 feet will be required for street construction. Development of the single family residence lots is expected to be one or two story wood frame homes. Foundation load information is not available at this time but for the purpose of our evaluation bearing wall loads for the residence structures are assumed to be on the order of 1 to 2 klf. If actual structural loads exceed the above values by more than 25 %, this office should be notified. _ .o. P,Q_ .x, 276, Issaquah, WA 98027 -0276 Phone: (206) 391 -4228 Fax: (206) 391 -422 p k z W r QQ L J O O 0 W I - I-- • L W o 2 u.Q = • d ▪ w z Zo LLJ Li) U � 0- 0 w W L I o U o � z Happy Valley Land Co. Project No. 98- 103 -01 SCOPE OF WORK February 10, 1998 Our geotechnical evaluation included subsurface exploration, engineering evaluations and the preparation of this report. The scope of work included the following specific tasks: z o Reviewed published geologic mapping of the site vicinity. i w CC o Performed a reconnaissance of the site to observed surface conditions. 0 o Observed the excavation of 5 test pits to depths ranging from 4 to 6 N W feet below the ground and excavated one hand -auger test pit on Lot 1,11 i 1 6. Approximate locations of the test pits are shown on Figure 2. cn w o Continuously logged the subsurface conditions, as encountered in the 2 test pits at the time of excavation. Logs of the test pits are presented on the summary sheets of Appendix A. N o Performed geotechnical engineering evaluations of the site and Z i developed geotechnical recommendations for site grading and general I- o site development. w I-- w o Prepared this geotechnical report summarizing our findings and D o recommendations. o Y2 O H w W OBSERVED SITE CONDITIONS 1- r `- o At the time of our field investigation the property was undeveloped except for the Lii existing residence and out - buildings on lots 5, 15 and 16 as shown on Figure 2. z Vegetation on the site consisted primarily of blackberries with grass and scattered o F- fruit trees and maple trees that ranged up to 3 + feet in diameter. Topography in the general site vicinity is gently to moderately sloped down to the east. The referenced topography map provided to • us indicates the maximum elevation difference across the site to be on the order of about 90 feet. Most of the site is gently sloped with gradients ranging from about 7 to 22 percent based on the topography map. Steeper slopes exist on the eastern half of Lots 15 and 16 where gradients of about 40 to 50 percent exist. Subsoils Our evaluation of the subsurface conditions was based on our observations of the exploratory test pits and surface observations. Subsoils encountered in the test pits were generally found to be natural glacial till soils with localized areas of fill soils. We noted apparent shallow fill deposits in the graded area of Lots 5, 15 and 16. The natural soils generally included a layer of dark brown topsoil with organics and roots which typically ranged from about 6 to 12 inches thick. The underlying weathered natural soils were typically brown to gray brown or gray and red -brown sandy silt or silty fine sand with gravel. The weathered soils were generally soft or loose to depths of about 2 to 3 feet below the natural surface based on the test pits Page 2 a ,. >+Nr,•e, rev>. k: �a: ew +wC���!mvre.1.n;••3:rtritar•rre :. M..'/' yiY "kflk;d'Iti.'yr'W.i?$ set Happy Valley Land Co. February 10, .1998 • and surface probing. Deeper natural soils were firm to very stiff /hard and medium dense to very dense to the depths of the test pits. Fill soils were encountered in Test Pit 6 to a depth of about 3 feet. The fill soils were very soft/loose and wet sandy silt/silty fine sand. Surface topography of Lots 5, 15 and 16 indicates other probable fill deposits in the graded areas around the existing house (see Figure 2). Ground Water We observed that the surface soils were generally very moist over most of the site and some areas were especially wet or had surface drainage or seeps as indicated on Figure 2. The site soils were generally classified as very moist to wet and measured moisture contents were generally high, ranging from about 17:1 to 40.6 percent. Most of the soils had moisture contents between about 20 to 30 percent. Seepage was typically observed at the • base of the upper weathered soils' in Test Pits 1 through 5. Ground water was observed to rise to about 9 inches below the fill surface in the hand - augered Test Pit 6 east of the existing house on Lot 16. . ubsurface Variations Based on our experience, it is our opinion that some variation in the continuity and depth of subsoil deposits and ground water levels should be anticipated due to natural deposition variations and previous onsite structures and grading. Due to seasonal moisture changes, ground water conditions should be expected to change with time. Care should be exercised when interpolating or extrapolating subsurface soils and ground water conditions between or beyond our test pits. General The referenced geologic map of Figure 1 indicates the site to expose glacial till (Qt) soils. The referenced map . describes the Qt soils as intimately graded mixture of clay to gravel sized soils. The glacial till was deposited during the advance of the Vashon glaciation, the last glacial advance into the Puget Sound area, approximately 13,000 to 16,000 years ago. Based on our explorations the site soils are sandy silt and silty very fine sand glacial till soils which are typically weathered, soft/loose and very moist to wet in the upper 2 to 3 feet becoming very stiff to hard below those depths. Fill soils were observed in the vicinity of Tots 5, 15 and 16. The upper weathered site soils and fill are not considered suitable for direct support of pavements or foundations, however, in our opinion the site can be developed as planned provided that our recommendations are followed. Project No. 98- 103 -01 SITE EVALUATIONS x +u Rr�+NSar.{m fr.aa �.� t�nYY; x. ;trt/+!et;i)>.a : °:*^s,"lt wni '{.':r: +tu.Ar :.,1.F M�:•ryi:.:;. Page 3 z Z re - U U o N O J = U) u_ wo 2 J u ? 1. a w = I-- _ z �. 1- o Z • ~ U � o 52 0 I- w W - r u o ..z w I • . I= z Happy Valley Lanu �o. February 10,.1998 Site Stability The referenced geologic map of Figure 1 does not indicate any known landslides in the site vicinity. Our observations of the existing site revealed no indications of recent or current instability. In our opinion the unweathered glacial soils which underlie the site are generally stable with regard to gross stability. There is always risk involved with construction on or near a slope and the lot owners must be willing to accept the risk of future instability which may result in damage to their property or neighboring property. In general slope failures are most likely to be shallow failures occurring during the winter and spring months due to increased soil moisture conditions and during earthquake shaking due to additional dynamic Toads on the slope. In our opinion the risk of damage due to instability on Lots 1-4 and 6 -14 is low. The risk of instability damage on Lots 5, 15 and 16 is considered moderate to high due to the wet conditions, the steeper slopes and existing fill. In addition the risk of shallow failures of the very steep road cut along 51st Avenue South is considered high. Risk of slope failure can be reduced by incorporating proper engineering design and providing and maintaining control of surface runoff and subsurface drainage. Site Grading Considerations Currently no street grading plan or street profiles exist, however we expect that cut/fill depths should be on the order of about 10 feet or less. We expect that the grades for Roads A and B will primarily be within the upper weathered soils which will not be suitable for direct subgrade support. The soft/loose weathered soils should be excavated from the street subgrade areas to expose stiff /hard soils and structural fill placed to the final street subgrade. Based on our experience the onsite soils will be quite moisture sensitive with regard to grading and compaction characteristics and the measured moisture contents indicate that the onsite soils are currently too wet to obtain adequate compaction. In our experience the onsite soils will be very difficult to compact unless they are dried out sufficiently. Site grading should be scheduled during warm, low humidity weather typically occurring in the late summer months to reduce the potential problems associated with wet soils and ground water seepage. Unless the onsite soils can be dried to near optimum moisture content, site grading will require the use of imported granular fill soils for proper compaction. In addition the onsite soils are not considered suitable for backfill within the drainage zone of basement walls or other retaining walls. Residential Foundations Existing soft/loose, organic and fill soils are not considered suitable for foundation support. Foundations should penetrate through the upper unsuitable soils to bear in very stiff /hard natural soils. In our opinion conventional spread footings founded on the very stiff /hard natural soils should provide good support for the residence structures. Where grading is performed to level specific Tots for development, all fill should be placed and compacted as structural fill. Project No. 98- 103 -01 Page 4 ((�W vr 1Qfflaawr II • z w 6 U O 0 CD 0 w F- U) w o • ? • a 1— w Z = 1-o Z ~ w • 0 o • - o 1- w u. g . ..z w O 1- 2 1 Happy Valley Land Co. February 10, .1998 The following subsections present our geotechnical recommendations for site grading, street subgrade preparation, residential foundations and retaining walls. Also included are recommendations for site drainage, erosion control, plan review and observations and testing during construction. z ~ w Site _Grading. 6 JU Site grading is expected to consist primarily of excavation and fill placement to u) o prepare the access roads subgrade, create building pads and backfill utility w = trenches and possibly retaining walls. Stripping depth required in areas with no N existing fill is expected to be about 2 to 3 feet. Excavation of the on -site glacial till w o materials is expected to be difficult at depths greater than about 5 or 6 feet. Onsite 2 soils are not generally considered suitable for use in compacted fills because in our experience these soils are quite moisture sensitive with regard to trafficability and u- compaction characteristics and are currently too wet for adequate compaction. If 2 d grading is scheduled for the late summer months moisture conditions of the onsite F- w soils may be more suitable for compaction. Site grading will likely require the use z of imported granular fill soils for proper compaction and drainage. z o ui w Onsite soils are not considered suitable for backfill against retaining walls because 2 o they will not be adequately free- draining. Retaining wall backfill will require clean o sand /gravel soils. o wW Recommendations for site preparation, temporary excavations, structural fill, 1 permanent slopes and street subgrade preparation are presented below. o z Site Preparation; Existing vegetation, debris, and soft or loose soils and existing fill 0 should be stripped from the areas that are to be graded. During rough grading, o I" excess soils may be stockpiled for later use. Soils containing more than 1% by z weight of organics may be used in planter areas, but should not be used for fill beneath building or pavement areas. Stumps, debris and trash, plus rocks and rubble over 6 inches in size, should be removed from the grading areas. Subsoil conditions on the site may vary from those encountered in the test pits. Therefore, ‘ the soils engineer should observe the prepared areas prior to placement of any new fills. Temporary Excavations: Sloped temporary construction excavations may be used where planned excavation limits will..not undermine structures or interfere with other construction. Where there is not enough room for sloped excavations, shoring should be provided. Contractors should note that excavation of the unweathered glacial till may be very difficult with conventional backhoe equipment. Based on the subsurface conditions encountered in our test pits, it is our opinion that sloped temporary excavations may be made vertically to depths less than 4 feet. Deeper temporary excavations up to 10 feet should be made at slope gradients no steeper than 1: 1 (horizontal:vertical) for the loose to medium dense soils and 3/4 : 1 (horizontal:vertical) for the glacial till soils, however it should be noted that the contractor is responsible for safety and maintenance of construction slopes. Project No. 98- 103 -01 RECOMMENDATIONS Page 5 two Happy Valley Land Co. February 10, 1998 Surface drainage should be directed away from the top edge of cut slopes. Surcharge loads should not be allowed within 5 feet of the top of cut slopes or within a 1 :1 (horizontal : vertical) plane extending up from the toe of excavation, whichever is greater. Structural Fill: Provided that soil moisture can be reduced and maintained near optimum, excavated onsite soils may be used for structural fill. However these soils are expected to be moisture sensitive and are currently too wet for practical compaction. Therefore imported granular fill soils should be used if moisture conditions cannot be adequately controlled. Loose soils, formwork and debris should be removed prior to placing fill or backfill. Imported free - draining granular soils should be used for backfill of retaining walls, and should be capped with pavement or 12 inches of onsite silty soils to reduce surface water infiltration. Onsite soils or imported granular fill should be placed in horizontal lifts not exceeding 8 inches in loose thickness and compacted to at least 90 percent of the maximum dry density as determined by the ASTM D1557 -91 test method. Imported granular fill should consist of clean, well- graded sand and gravel materials free of organic debris and other deleterious material. Imported material for wall drainage zone backfill should be a clean sand /gravel mixture with less than 5 percent fines based on the sand fraction. Fill Slopes: All permanent fill slopes should be constructed of properly placed and compacted structural fill with gradients no steeper than 2:1 (h :v). All existing fill, vegetation, debris, and loose /medium dense soils should be removed from proposed fill slope areas prior to fill placement (see "Site Preparation "). Where underlying natural slope gradients are 20% or more, fill slopes should be keyed and benched into undisturbed dense natural soils. Key width should be at least 8 feet or 1/3 the slope height whichever is greater. Key depth should penetrate at least 2 feet into undisturbed dense natural soils. All fill should be placed and compacted in accordance with the recommendations for "Structural Fill ". Cut Slopes: All permanent cut slopes should be made no steeper than 2 :1 (h:v). Existing trees located within 10 feet of the top of the cut slope should be cut but stumps should be left intact. �Jtility Trench. s: Buried utility conduits should be bedded and backfilled around the conduit in accordance with the project specifications. Where conduit crosses pavement subgrade areas the backfill above the pipe should be placed and compacted in accordance with the recommendations for structural fill. .Street Subgrade Preparation The street pavement section (base course and A.C. paving) should be supported on a subgrade compacted to at least 95 percent of the ASTM D1557 maximum dry density. Subgrade preparation should include stripping of existing vegetation, topsoils and soft/loose weathered soils in accordance with the "Site Preparation" recommendations. Project No. 98- 103 -01 Where unsuitable soils exist at subgrade level, subgrade preparation should include over - excavation down to expose stiff to very stiff /hard natural soils and placement of structural fill to final subgrade elevation. Subgrade fill should be placed in accordance with the recommendations for structural fill except that the top 6 inches dia Page 6 z ~ w re _1 U UO 0 w= w o g • d w z = � z t- w uj • p U 0 1- w W ~ • F___ o w z U P ce O z • Happy Valley Land Co. February 10, 1998 of the subgrade fill should be compacted to at least 95 percent of the ASTM D1557- 91 maximum dry density. R eside ntial Spread E _E oslia ct ations z Conventional spread footings founded on undisturbed very stiff /hard natural soils should provide good support for residential structures within the proposed plat. All I- z footings should be founded at least 18 inches below the lowest adjacent final grade Ce j and should be deepened as required to penetrate existing soft/loose natural soils U and fill to bear on very stiff /hard natural soils. In addition, square footings and c.) o continuous footings running parallel to the slope should be deepened as required to u) W provide a set back at least 12 feet horizontally from the face of the slope. Footings Ili i should also be setback beyond a 1:1 (h:v) projection from adjacent lower footings. u. All footings should be stepped as necessary to maintain a horizontal bearing • su rf ace. .<1- J Suitable stiff /hard bearing soils are expected to be at depths of about 2 to 3 u D feet below the natural surface. The depth to bearing soils may be increased due to i w existing fill overlying the natural surface. z 1 As an alternative to deep spread footings to penetrate soft/loose soils or fill and /or w o satisfy slope setback requirements, foundation loads may be transferred from the ? o recommended minimum foundation depths to the recommended bearing soils by a monolith of lean concrete having a minimum compressive strength of 1000 psi. The oo 2 w idth of an unreinforced lean concrete monolith should be at least as wide as the footing or at least one -half of the monolith height, whichever is greater. Reinforced i 0 monoliths should be designed by''a structural engineer. A suitable width trench u. o should be excavated with a smooth edged excavator (no teeth) to expose the - z dense /very dense bearing soils under observation by our office and backfilled as iii 0 0 soon as possible with the lean concrete to the footing elevation. r.. " 0 z Square footings should be at least 24 inches wide and continuous wall footings should be at least 16 inches wide for two story structures. Continuous footings for garages or other light structures with loads less than 1 kip /ft may be reduced to a minimum width of 12 inches. Footings may be designed based on an allowable bearing pressure of 2000 psf. Settlement of light wood -frame structures is expected to be within tolerable limits for this type of construction. For example, the estimated settlement of a 16 inch wide continuous footing founded on very..stiff/hard natural soils and carrying a load of 2 kips /ft. is on the order of 1/2 inch. Settlements are expected to occur primarily during construction. For lateral design, resistance to lateral loads can be assumed to be provided by friction acting at the base of foundations and by passive earth pressure. A coefficient of friction of 0.35 may be assumed with the dead load forces in contact with onsite soils or structural fill. An allowable static passive earth pressure of 250 psf per foot of depth may be used for the sides of footings poured against undisturbed natural soils or properly compacted structural fill. The bearing values indicated above are for the total dead load plus frequently applied live loads. If normal code requirements are applied for design, the vertical bearing values may be increased by 50% for short durations of loading which will Project No. 98- 103 -01 Page 7 ti Happy Valley Land Co. February 10, 1998 . include the effects of wind or seismic forces. Allowable lateral passive pressures may be increased by 33% for wind and seismic forces. Retaining Walls Cantilevered retaining walls as referred to in this report are walls which yield or move outward during and after backfilling. Actual wall movements will depend on the wall design and method of backfilling and can range from 0.1% to 0.3% of the wall height. Design pressures for cantilevered walls given below assume that the top of the wall will deflect at least 0.2% of the wall height. Static design of permanent cantilevered retaining walls which support a horizontal surface of properly compacted clean free - draining granular material may be based on an equivalent fluid density of 35 pcf. This pressure assumes that there is no water pressure behind the wall. A uniform lateral pressure due to backfill surcharge should be computed using a coefficient of 0.25 times the uniform vertical surcharge load. Static design of walls structurally braced against movement should be based on an equivalent fluid density of 60 pcf. This pressure assumes that the wall supports a horizontal backfill of properly compacted free - draining (imported) granular material and that there is no water pressure behind the wall. Uniform lateral pressure due to a uniform vertical surcharge behind a braced wall should be computed using a coefficient of 0.45 times the uniform vertical surcharge load. Seismic design of retaining walls should include a dynamic soil loading based on a 0.24g 475 -year UBC recurrence ground motion level. Dynamic soil pressure should be assumed to have an inverted triangular distribution. The dynamic soil pressure at the top of the wall should be at least 20H (psf) where H is the height of the wall above the footing base. The dynamic soil pressure should diminish linearly to zero at the base of the wall. Combined static plus dynamic soil pressure should be used for seismic design of the walls. Care should be exercised in compacting backfill against retaining walls. Heavy equipment should not approach retaining walls close enough to intrude within a 1:1 line drawn upward from the bottom of the wall. Backfill close to walls should be placed and compacted with hand - operated equipment. Recommendations for placement and compaction of structural fill are presented under "Site Grading ". Design wall pressures given above assume no water pressure behind the walls. We recommend that a drainage zone be provided behind all retaining walls and a adequate drain system be provided at the base of all retaining walls. As a minimum, the •drainage zone horizontal dimension should be 3 feet or 1/2 the wall height, whichever is less. Backfill within the drainage zone should be a clean sand /gravel mixture with less than 5 percent fines based on the sand fraction. A membrane of Mirafi 140 filter fabric or equivalent should be provided between the drainage zone material and onsite silty soil backfill. • Wall drains should consist of a four -inch diameter perforated PVC drain pipe placed in at least one cubic foot of drain gravel per lineal foot along the base of the wall. Drain gravel should be washed material with particle sizes in the range of 3/4 to 1 -1/2 inches. The drainage zone backfill should be capped with paving or 12 inches of silty soils to reduce surface water infiltration. Project No. 98 -103 -01 Page 8 Happy Valley Land Co. February 10, .1998 Conventional spread footing foundations founded on undisturbed very stiff /hard natural soils may be used for support of retaining walls. Design of wall foundations should be in accordance with the recommendations presented in this report. Drainage Control . Surface drainage from the adjoining upslope areas should be controlled and diverted around the development area in a non - erosive manner. Adequate positive drainage should be provided away from the structure and on the site in general to prevent water from ponding and to reduce percolation of water into subsoils. Granular backfill should be capped with paving or 6 inches of onsite silty soils. A desirable slope for surface drainage is 2% in landscaped areas and 1% in paved areas. Roof drains should be tightlined into the storm drain system or other appropriate discharge point (no discharge on the ground surface). A permanent perimeter drain, independent of the roof drain system, should be placed adjacent to the base of the continuous exterior foundations. The drain should consist of a four -inch diameter perforated PVC drain pipe placed in at least one cubic foot of a well graded sand and gravel filter material per lineal foot along the base of the foundations. At least one interior drain should be provided beneath the basement floor connecting to the perimeter drain on the downslope side at the lowest point. If conditions exposed during construction warrant, interceptor subdrain system(s) may be required to intercept ground water migration form the upslope areas particularly in the eastern site area. Interceptor drains should consist of a filter fabric lined trench filled with clean sand or drain rock with a perforated PVC drain pipe at the base. The drain trench should be at least 18" wide, and at least 3 feet deep and should penetrate at least one foot into the very stiff /hard natural glacial till soils. Six inches of native clay soil cover should be placed over the drain to reduce surface water infiltration. Discharge from the subdrain should be conducted via tightline to the storm drain system. In the proposed street subgrade structural fill areas a drain pipe should be installed to collect ground water infiltration which may collect in the fill and transmit it to the storm drain system. The subdrain pipe should be placed along the lower side of under the street fill areas and should discharge to the storm drain system. As a minimum the drain should consist of a 4" diameter perforated PVC collector pipe and a tightline discharge pipe. Additional lateral drains should be provided wherever a spring or seep is exposed during grading. Erosion Contro( Onsite silty materials are expected to be highly erodible when exposed to concentrated flows. Siltation fences or other detention devices should be provided around soil stockpiles and exposed soil areas during construction to control the transport of eroded material. Exposed final graded soil areas should be paved or planted immediately with grass and deep rooted plants to help reduce erosion potential. Project No. 98- 103 -01 » ».. • �y. ....�..: •, �.;rr *�. - -- ,.,., .,w>rw.r. „M..... �,.,wn...... sr�erc� Page 9 z 1- 6 J 0 N J co -w u- m i 1- z z w 0 0 0 w 1- LL ui 0 0 z z w 0 0 w s F- w 0 a 0 0 0 S 4 • Respectfully submitted, GEOSPECTRUM CONSULTANTS, INC. Project No. 98 -103 -01 &2 t James A. Doolitt Principal Engineer Encl: Figures 1 and 2 Appendix A Dist: 1 /Addressee 2 /Baima & Holmberg, Inc. CLOSURE r . Happy Valley Land Co. February 10, .1998 Plan Review This report has been prepared to aid in the evaluation of this site and to assist the civil engineers in the design and construction of the project. It is recommended that this office be provided the opportunity to review the final design drawings and specifications to determine if the recommendations of this report have been properly implemented and to make any supplemental design recommendations which may be required. Observations and Testing During Construction Recommendations given in this report are based on the assumption that all development construction will be performed under engineering observations and testing. All structural fill and backfill areas should be observed by a representative of this office after stripping and prior to placing fill. Proper fill placement and compaction should be verified with field and laboratory density testing by a qualified testing laboratory: All footing excavations should be observed prior to placement of steel and concrete to see that footings are founded on satisfactory bearing materials and have proper slope setback. This report was prepared for specific application to the subject site and for the exclusive use of the Happy Valley Land Company and their representatives. The findings .and conclusions of this: report were prepared with the skill and care ordinarily exercised by local members of 'the' geotechnical profession practicing under similar conditions in the same locality. ' We make no other warranty, either 'express or implied. Variations may exist in site conditions between those described in this report and actual conditions encountered during construction. Unanticipated subsurface conditions commonly occur and cannot be prevented by merely making explorations and performing reconnaissance. Such 'unexpected conditions frequently require additional expenditures to achieve a properly constructed project. If conditions encountered during construction appear to be different from those indicated in this report, our office should be notified. EXPIRES 3/19/ g Page 10 z � w 00 • Cl • LU J = w o E LO. I`- w z I- 0 Z r` w W U o o 2 o w • w L I o w z U N 0 ref: Preliminary Geologic Map of Seattle and Vicinty, Washington, by Waldron, Liesch, Mullineaux and Crandell, USGS Map I -354, 1962, scale: 1" =2640' GEOSPECTRUM CONSULTANTS, INC. Goatoahn /col Enp /noorJnp and Earrh Solo/ICCPI Proj. No98 -103 SITE VICINITY GEOLOGIC MAP Date 2/98 Proposed Foster Heights Development South 146th Street & 51st Avenue•South Tukwila, Washington Figure 1 ref: Preliminary Geologic Map of Seattle and. Vicinty, Washington, by Waldron, Liesch, Mullineaux and Crandell, USGS Map 1-354, 1962, scale: 1".2640' GEOSPECTRUM CONSULTANTS, INC. SITE VICINITY GEOLOGIC MAP Date 2/98 Four e 1 • 25 Proposed Foster Heights Development South 146th Street & 51st Avenue South Tukwila, Washington File: D 02 -0051 35mm Drawing #1 } APPENDIX A FIELD EXPLORATION Our field exploration included a site reconnaissance and subsurface exploration program. During the site reconnaissance, the surface site conditions were noted, and the locations of the test pits were approximately z determined. , 1 z The test pits were approximately located using existing features as a guide. re 1 Elevations at • the test pits locations were estimated from the site plan 6 o prepared by Baima & Holmberg dated 9/12/97 combined with our own site o o measurements. J H Test pits were advanced using a Yatani 140 -B trackhoe excavator. Soils N u. were continuously logged and classified in the field by visual examination, in . o accordance with the ASTM Soil Classification system. 2 ga u.¢ Logs of the test p its are presented on the test pit summary sheets A -1 u) d through A-3. The test pit summaries include descriptions of the soils and I' w pertinent field data. Soil consistency and moisture conditions indicated on z i the logs are interpretations based on the conditions observed in the field. 1- o Boundaries between soil strata indicated on the logs are approximate and Z Ill w actual transitions between strata may be gradual. w /abundant roots to 1/2" soft very moist ark rown Sandy Silt, very. fine • w/ ,pc. rounded gravel to mottled ra LSron A_ �rown wet ____ — -- firm — — — — s - tiff — tif to very stiff hard ---- moist _Sepage di digging —_ , Maximum depth 6 ft. • Seepage at approximately 2 feet. • Logged By JAD Date 1/23/98 Depth pfows USCS Logged By JAD Date 1/23/98 5M ML Topsoil /Organics Sandy Swlocicygravelfito and 4 � grading to Sandy Silt, very fine GEOSPECTRUM CONSULTANTS, INC. TEST PIT NO. 1 Maximum depth 6 feet. Seepage at approximately 1 foot. Soil Description loose/ to firm steiW to hard dk brn TEST PIT NO. 2 Proj. No.98 -103 moist wet ver most Date 2/98 mottled pray- Drown red -brown Elev 464' w (%) 29.8 S eepage difficult digging Elev. 448' TEST PIT LOGS Proposed Foster Heights Development South 146th Street & 51st Avenue South Tukwila, Washington Figure A -1 — — — — — =-- — -- -- Topsoil /Organics loose • moist to very moist dark rnwn 19.1 24.1 • =Gavin y Seepage SM Silty very fine Sand w/ occ. gravel to 3" grown B oin — — --- medium dense mottled Peown & r7-own _ — — ' Mt -- SP Sand, fine -med • dense gray — — wet SM Silty fine Sand v.dense v.moist gray -brn — — Maximum depth 6 ft. • . Seepage at approximately 4.5 - 5.5 feet. • L ogge d B JAD Date 1/23/98 Depth SloWS USCS 0 s 1 — 2 — 3 -- 4 -- 5 -- 6 — 7 — ML Topsoil /Organics Sandy Silt ravel to 3" w /trace clay Maximum depth 4.5 feet. Seepage at approximately 1 - 2 fey TEST PIT NO. 3 Soli Description soft firm very to hard t. moist wet very moist dk brn gray- Drown mottled ra - r n r -brown Elev. 422' w (%) 40.6 Seepage 4 Logged By ,lAn Date 1/23/98 0 1 2 3 5 6• 7 TEST PIT NO, 4 Elev. 423' GEOSPECTRUM CONSULTANTS, INC. • ti• .v. • 1. \x =�:: /•. c •otochfl /co/ Eno /flooring and Eorth Sc/anoo TEST PIT LOGS Proposed Foster Heights Development South 146th Street & 51st Avenue South Tukwila, Washington Pro'. No98 -103 Date 2/98 Figure A -2 St:n z 1 e: 6 U U, co J w LL z I- z w U 0 w H w iii U 0 z z w U 0 0 w 2 H w 0 J w E- 0 F- w 0 H W U 1= 0 aged By JAD Date 1/23/98 Depth (ft. lows USCS 0• 1 — 2 3 4 5 — 6 — 7 — ML Topsoil /Organics w /abundant roots to 1" Sandy Silt, very fine & occ gravel to 3" & Silty fine Sand Maximum depth 4 feet. Seepage at approximately 1.5 - 2. GEOSPECTRUM CONSULTANTS, INC. G ootoc hnlcal 6 and Earnh Sc/onaos TEST PIT NO. 5 Soil Description soft firm chard 5 feet. moist to wet very moist dark brown Brown 9ry red- brown Proj. No .98 -103 Date 2/98 Bev 428 W (%) 37.3 17.1 .cuing_ Seepage Figure A -3 4 Logged By JAD Date 1/23/98 0 1 2 3 5 6 7 TEST PIT NO. 6 Elev 408' SM Topsoil/Sod Sandy Silt/Silty fine Sand gavel — becomes more Sandy Maximum depth 5 ft. Water at 9 inches after 15 minute ve: l ° o se d edium ense to dense $. wet very moist dk -brn ixed rn It- rn brown pak d mottl�d &rrr d -brn 30.4 20.5 FILL TEST PIT LOGS Proposed Foster Heights Development South 146th Street & 51st Avenue South Tukwila, Washington , rin 111 , Z w Q J U O 0 0 W I f- v) w w0 w = w Z �. I- 0 Z F- w w O • N O I-- W ul L I O l l Z U N H 1- z WATTSUN 5.5B 1994 WA STATE ENERGY CODE COMPLIANCE REPORT 11/06/80 FILE: C: \ \WATTSUN5 \ \LCH472.WS HEATING /COOLING /VENTILATING SYSTEMS Heating System Type: Make Model: System Efficiency: Modified Efficiency: Design ACH: Design Load(at 44F dt): Duct Losses (% Dsn Load) : Total Load: System Size(Output) Average Annual Heat: Annual Cost: Ventilation System: Cooling System: SEER: Cooling Load(at 4F dt) System Size( %Over): Annual Cool Requirement: PROPOSED DUCT SYSTEM • .SUPPLY RETURN Solar Access: GLAZING ORIENTATION PROPOSED South ft2. Southeast :. East Northeast : Eff S Glz: 0.60 34393 8690 43082 64500 i 1.6% PROPOSED Gas Furnace - carrier pav pav / Vented crawlspace Attic or garage 80 % ° 61 %, 127 MBtu $ 700 Integrated Spot & Whole House T FJLE COPY Btu /hr Btu /hr (25 %) Btu /hr Btu /hr (150 %) NONE . 0.0 (Ducted) Btu /hr tons (@125 %) kWh /yr Partially Shaded R- 8.0 R- 8.0 RECEIVED CITY OF TUKWILA FEB 2 G ?_002. PERMIT CENTER Location Avg Rvalue Surface Area 593.6 ft2 118.7 ft2 PROPOSED North 235.0ft2 Northwest : West Southwest : Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. HOUSE ID: LCH472 ‘S:sci? -os 1/ m.o a -0 39 z < J U 00 c J H u O g< 1 z � 1- O Z f- D c O • - 0 I- W OC uu t- UL O w z = O ff ' z WATTSUN 5.5B FILE: C: \ \WATTSUNS \ \LCH472.WS Site: Homeowner: Builder: The PROPOSED design *COMPLIES* with 1994 WA State Energy Code. COMPONENT PERFORMANCE ENERGY BUDGET REFERENCE DESIGN Component Floor Glazing @15% Doors AG Wall Ceiling, Attic Infiltration PROPOSED. DESIGN COMPONENTS Component Floor Glazing @8.1; Doors AG Wall Ceiling Infiltration Struc Mass ■ • 1994 WA STATE ENERGY CODE COMPLIANCE REPORT 11/06/80 Description Value R19 vented Joist 16oc U -0.041 2g1 Wood /Vinyl <1/2 ", Clr U -0.630 Metal 1 3/4 ", urethane flush -Ftb f! U -0.140 R19 STD Lap Wood U -0.062 R30 blown Attic STD baffled .U-0.036 Standard Air Sealing ACH -0.350 Light Frame, Sheetrock walls M- 3.000 Analyst: Jurisdiction: Utility: House Type: Single Family Floor Area: 2968 ft2 ' R J Weather Data: Seattle, WA Climate Zone: 1 " REFERENCE PROPOSED 612 459 Btu /hr -F 10.03 8.62 kWh /ft2 -yr HOUSE ID: LCH472 Reference Value X Area UA U -0.041 U -0.650 U -0.390 U -0.062 U -0.036 ACH -0.350 Reference UA Proposed UA 1306 53.5 445.2 289.4 100:0 39.0 2958 . 183.4 1306 • 47.0 26712ft3( 171.1) X Area = UA 1306 235.0 100.0 3168 196.4 1306 47.0 26712ft3 (171.1) 2968 Items in parentheses not included in COMPONENT PERFORMANCE totals. 'Page 1 612 53.5 148.1 14.0 459 8904 • ru, Aee tv��w: M. CSx!# ffke�GrkA* ean�wr...,•-.,.., ,avwr...r.,+•,.R.�:•.w,w�w :a�3 z , ~ w JU 00 w = J H w 2 u.Q I el Z I- O Z F- w W U � 0 o w H lL O w z 0 z NO MANUFACTURER FRAME MATERIAL MODEL # SIZE U -VALUE AREA S.F. 1. HEAT SOURCE: 5L�`�S' (gas, oil, propane, heat pump, electric) 2. WINDOW SCHEDULE: Fill in the window schedule based upon the proposed residential design and calculate the glazing area as % of the conditioned floor area. 3. CHECK PRESCRIPTIVE OPTION: Glazing percentage will determine which option to choose. Mark option at top of column. (See back of this sheet) WINDOW SCHEDULE GLAZING /SKYLIGHTS BY TYPE CCaPY �"� T OTAL GLAZING AREA S.F. . Residential Energy Code Form HI 9/10/01 CITY Cµ-' TUKWILA 1 2/4 X Permit Center 447 Z- 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 WASHINGTON STATE ENERGY CODE RESIDENTIAL COMPLIANCE FORM PRESCRIPTIVE APPROACH TOTAL CONDITIONED FLOOR AREA TOTAL GLAZING AREA 3 (add entire column) S.F. x 100 = ACTIVITY #:, O ; ' 1 7 PROPOSED GLAZING PERCENTAGE RECEIVED CITY OF TUKWILA I- B 2 6 2002 PERMIT CENTER The proposed glazing percentage must be less than or equal to the glazing percentage listed under the prescriptive option that is selected. • Address: Permit* a: EC':Ch apter 6 Qualification Form; Z one 1 Other fuels Residential Prescriptive' (Chapter 6) Options for Heat Source.: Other fuels Instructions: 1) Carefully review the requirements for each of the options below. Choose an option that best suits your dwelling design. Glazing percentage typically determines which option to choose. Your building must match the selected option requirements without exceptions or substitutions. 2) Check ✓ the 0 above the requirements of your option. Disregard components or equipment that do not apply to your project :. Your permit will be processed more efficiently if you provide all of the requested information. Department staff can help you with general questions about this Can't Comply? If none of the Prescriptive (Chapter 6) options are acceptable, consider the Component Performance (Chapter 5) Approach. Note that the Component Performance requirements are no less stringent than the Prescriptive requirements. Calculations may be performed with a 2000 WSEC Chapter 5 Residential Qualification Form, or by using an acceptable computer program•such as WATTSUN. CHECK ✓ One ilk 'HVA.0 :Efficiency' .Glazing max; % of flo:o r4 ........ :::;:Vert:: U factor 'Overhe:ad: Glazing U Factor: ::: Door U- Factor ! r: R- factor Ceilingsi ? : : . : ::::wlattics vaulted ''abov.e;grad :e•. : .:::` ::::.:::in erior:::or Floor. `Siabdngrad Footnotes: OPTIl 0 Med 10% 0.7'0 0.68. 0.40 R -2.5) R -30 R -30 R -15 'R -15 R -10. R -19 R -10 iN OP.TION OPTION OP.TION:. .OPTION • OPTIO ;`:' OPTION OPTION: II III ...: IV : ::V VI?. VII: ..:VII! 0 Med 12% 0.65 0.68 0.40 (R -2.5) R -30 R -30 R -15 R -15 R -10 R -19 R -10 0 High 21% 0.75 0.68 0.40 (R -2.5) R -30 R -30 R -19 R -19 R -10 R -19 R -10 it Med 21% 0.65 0.68 0.40 (R -2.5) R -30 R -30 R -19 R -19 R -10 R -19 R -10 0 Low 21% 0.60 0.68 0.40 (R -2.5) R -30 R -30 R -19 R -19 R -10 R -19 R -10 0 Med 25% 0.45 0.68 0.40 (R -2.5) R -38 R -30 R -19 R -19 R -10 R -25 R -10 0 0 Med Med 30% 0.40 0.68 0.40 (R -2.5) R -30 R -30 R -19 R -19 R -10 R -25 R -10 1. Nominal R- values are for wood frame assemblies only, or assemblies built in accordance with Sec. 601.1 2. The following options are applicable to buildings 2 stories or less: 0.50 MAX for glazing areas of 25% or less; 0.45 MAX for glazing areas of 30% or less. 3. Min. HVAC equipment requirements: 'Low' AFUE 2 0.74. 'Med' AFUE >_ 0.78. 'High' AFUE >_ .088. Heat Pumps: 'low' HSPF 2 6.35; 'Med' HSPF >_ 6.8; 'High' HSPF >_ 7.7. Water & ground source heat pumps are 'med' and shall meet a minimum COP per WSEC Table 5 -7. 4. (Vertical + Overhead Glazing) T conditioned floor area = maximum glazing percentage. Overhead glazing with a U- factor of .40 or less is exempt from glazing percentage calculations. 5. Glazing, skylight, and door U- factors may be weighted to meet the U- factor requirements. Jate; WasMngton State University Energy Program C6Z11: :.V.aoc ode dr) unlimited .25 0.40 0.40 (R -2.5) R-30 R -30 R -19 R -19 R -10 R -25 R -10 !� p proveldi B Revised 0125101 Project Name: , __. Address: Residential Building Permit Number: • . 1. Prescriptive Option W.S.E.C. Chapter 6, (check building permit option used): ❑ I. ❑ II ❑ ill. iv. ❑ V. ❑ V ❑ vu. ❑ VIII. 2. House Square Footage (HSqFt) 06/2 3. Heating System installed, (check system type below): ❑ a. Electric Resistance /21 BTU /h per sq. ft. ❑ b. Electric (forced air) /24 BTU /h per sq. ft. c. Other Fuel heat pump) /27 BTU /h per sq. ft. 4. Equipment: a., Make cARI 5 b. Model jrA, C) 2 7O - 7 c. Size in BTU's 5. Calculation/(HSqFt) ' Z 61Z (see line 2 above) ' t BTU /h X z7 (see line 3 a, b, or c above) . 7.0 5Z ¢ BTU Equipment Maximum Size PERMIT APPLICATION #: Applicant's Signature: 7/9/96 47? CITY OF TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 Prescriptive Heating System Sizing for Single Family Homes - New Construction Washington State Energy Code Chapter 9, Climate Zone 1 H -6 Date: PERMIT NO. DATE: PROJECT NAME: o ? z 11/& l� 7 474. WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE. Mechanical ventilation criteria using ,prescriptive methods for Group R Occupancies four stories and less,. (Group R Occupancies: Hotels, apartment houses, congregate residences, dwellings and lodging houses.) Each dwelling unit or guest room shall be equipped with source specific and whole house ventilation systems. Source specific, exhaust fans are required in the following locations: bathrooms, laundries and kitchens. Minimum fan flow rating = 50 cfm @ 0.25 inches water gauge for bathrooms and laundries, and 100 cfm @ 0.25 inches water gauge for kitchen exhaust fans. Ite4 Locate exhaust .fans on plan(s) and note fan flow performance rating for each fan. 4 Exhaust ducts shall be equipped with back -draft dampers. Note this requirement on plans. 4. All exhaust ducts located in unconditioned spaces shall be insulated to a minimum of R -4. Note this requirement on plans. Whole house ventilation shall be provided by a system that meets the requirements of either: V.I.A.Q. Section 303:4.1 Section 303,4.2 Section 303.4.3 Section 303.4.4 Indicate on plans a proposed system to be used. (Refer to attached code sections, select one, and list here: T.C. SIZE 2 X 4 T.C. CUT HEIGHT 2" 2X6 2X6 LOADING: 25.0.7.0.0.0.5.0 SPACING: 24.0 IN. O.C. (TYP.) AP COMP No. MK TYPE SLOPE SPAN OVtKHHNG REMARKS Ltl 1 RICH I PLAN NO. L -R 472 B L 1 T01 6 20 -00 -00 18 18 GABLE: SHEATHED ONE SIDE 3 T02 6 20 -00 -00 18 18 COMMON : SUPER ANCHOR (1) TRUSS 1/2 T03 6 20 -00 -00 18 0 SUPTS 36 -0 1 T04 6 , 13 -00 -00 18 18 GABLE: SHEATHED ONE SIDE 1/2 T05 6 13 -00 -00 0 18 SUPTS 36 -0 1 T06 ,,,Ilali1011lllllih. 6 ;36 -00 -00 18 0 GABLE 9 T07 6 . ' 36 -00 -00 18 0 COMMON : SUPER ANCHOR (1) TRUSS 4 TO7A 6 36 -00 -00 18 18 COMMON : SUPER ANCHOR (1) TRUSS 6 T07 6 36 -00 -00 18 0 COMMON : SUPER ANCHOR (1) TRUSS 1 T06 ,,,IIIIIIIIIIIIIIIII.. 6 36 -00 -00 18 0 GABLE 1 T04 6 13 -00 -00 18 18 GABLE: SHEATHED ONE SIDE 3 TO8 6 13 -00 -00 18 18 COMMON 1 TO8A 6 13 -00 -00 0 18 COMMON CIT OF TUKW r.ER 2 6 2002 11 4'EJ 6 04 -00 -00 18 0 JACK rCPM CE 4TER 15 Hangers MSH29 30 Quad2000 11- STABILIZERS 4 Quad2000 10- ARS INSTALLED 55 Blocks 2x 4 Vent 22 -7/16" 6 Quad2000 14- GE LABOR LABOR TO SHEET GABLE TRUSS DEPARTMENT 0 �1111» E �• /'P4, ► .oO 14P!' SHEET NO.1 LONG CLASSIC HOMES L 1624 PIONEER STREET o ENUMCLAW, WA 98022 o (360) 802 -1880 H LONG CLASSIC r P o TUKWILA, PHONE: (425) 488 -1818 FAX: (425) 398 -3559 CONTACT: PHONE: (360) 678 -4022 PROJECT: FOSTER HEIGHTS BY: KRE SALES' � •+ r� DELIVERY INSTRUC ONS: F I I - �`? r SPE 4L INSTRUCTIONS: TRUSS QUOTE /ORDER QUOTE #: B0110100 INVOICE #: CUST: LONGCLAS PO NO, TERMS 10 -00 -15 3031 ORDER DATE BID DATE DELIVERY DATE 11/17/00 JOB NO. PLAN NO. L -R 472 B L TRUSS DEPARTMENT 0 �1111» E �• /'P4, ► .oO 14P!' SHEET NO.1 LONG CLASSIC HOMES L 1624 PIONEER STREET o ENUMCLAW, WA 98022 o (360) 802 -1880 H LONG CLASSIC r P o TUKWILA, PHONE: (425) 488 -1818 FAX: (425) 398 -3559 CONTACT: PHONE: (360) 678 -4022 PROJECT: FOSTER HEIGHTS BY: KRE SALES' � •+ r� DELIVERY INSTRUC ONS: F I I - �`? r SPE 4L INSTRUCTIONS: TRUSS QUOTE /ORDER QUOTE #: B0110100 INVOICE #: CUST: LONGCLAS PO NO, TERMS HEIGHT tai. VV .LL KOOK T.C. SIZE T.C. CUT HEIGHT 2x4 SIZE 2X6 LOADING: SPACING: . APE COMP No. MK TYPE SLOPE SPAN UVbKHMNU REMARKS LEFT RIGHT PLAN NO. L -R 472 B L 6 Ouad2000 15- GE OSB SHEETS OF GABLE SHEATHING .TRUSS DEPARTMENT 111 4$ rr SHEET NO.1 2 LONG CLASSIC HOMES g 1624 PIONEER STREET n ENUMCLAW, WA 98022 o (360) 802 -1880 PHONE: (425) 488 -1818 FAX: (425) 398 -3559 s LONG CLASSIC P o TUKWILA, CONTACT: PHONE: (360) 678 -4022 PROJECT: FOSTER HEIGHTS BY: KRE DELIVERY INSTRUCTIONS: SALES :WAYNE BRIGDEN Total Weight: 3909 OA Truss Height: 10 -00 -15 ACCEPTED BY BUYER NAME: DELIVERY SUB -TOTAL NO SALES TAX GRAND TOTAL Included $3,032.00 $3,032.00 SPECIAL INSTRUCTIONS: TRUSS QUOTE /ORDER QUOTE #: B0110100 INVOICE #: CUST: LONGCLAS PO NO. TERMS 10 -00 -15 3031 ORDER DATE BID DATE DELIVERY DATE 11/17/00 JOB NO. PLAN NO. L -R 472 B L .TRUSS DEPARTMENT 111 4$ rr SHEET NO.1 2 LONG CLASSIC HOMES g 1624 PIONEER STREET n ENUMCLAW, WA 98022 o (360) 802 -1880 PHONE: (425) 488 -1818 FAX: (425) 398 -3559 s LONG CLASSIC P o TUKWILA, CONTACT: PHONE: (360) 678 -4022 PROJECT: FOSTER HEIGHTS BY: KRE DELIVERY INSTRUCTIONS: SALES :WAYNE BRIGDEN Total Weight: 3909 OA Truss Height: 10 -00 -15 ACCEPTED BY BUYER NAME: DELIVERY SUB -TOTAL NO SALES TAX GRAND TOTAL Included $3,032.00 $3,032.00 SPECIAL INSTRUCTIONS: TRUSS QUOTE /ORDER QUOTE #: B0110100 INVOICE #: CUST: LONGCLAS PO NO. TERMS long classic 472 b drawing LOADING (psf) TCLL 25.0 TCDL 7.0 BCLL 0.0 BCDL 5.0 iruss LUMBER TOP CHORD 2 X 4 HF No.2 BOT CHORD 2 X 4 HF No.2 WEBS 2 X 3 SPF Stud /Std LOAD CASE(S) Standard 5 -3 -4 5 -3 -4 iruss ,e ROOF TRUSS 10 -0 -0 10 - 0 - 0 10 -0-0 4 -8 -12 4x4 = 4 s 3x8 = Qty Ply 3 1 g 14 -8 -12 4 -8 -12 WARNING- Verify design parameters and READ NOTES ON THIS AND COVER PAGE BEFORE USE. This design is based only upon the parameters shown, and Is for an Individual building component to be installed and loaded in the plane of the truss. Applicability of design parameters and proper Incorporation of component is the responsibility of the building designer. The bracing requirements shown are for lateral stability of individual truss members. The bracing design is the responsibility of the building designer. Additional temporary bracing to insure stability during construction is the responsibility of the erector. For general guidance regarding fabrication, quality rnnlrnl atnrana &W on) arantinn and hrarinn rnnei,lf OST Quality Standard. DSR.80 8nclna Sneriflratinn. SPACING 2 -0 -0 Plates Increase 1.15 Lumber Increase 1.15 Rep Stress Incr YES Code UBC /ANSI95 CSI TC 0.35 BC 0.82 WB 0.33 DEFL in (loc) 1 /deft Vert(LL) -0.27 2 -8 >877 Vert(TL) -0.41 2 -8 >574 Horz(TL) 0.03 6 n/a 1st LC LL Min I /defl = 240 REACTIONS (lb /size) 2= 834/0 -5 -8, 6= 834/0 -5 -8 Max Horz2= 42(load case 4). FORCES (lb) - First Load Case Only . TOP CHORD 1 -2 =21, 2 -3= -1104, 3-4= -784, 4 -5= -784, 5 -6= -1104, 6 -7 =21 BOT CHORD 2 -8 =974, 6 -8 =974 WEBS 3 -8= -310, 4 -8 =388, 5 =--310 NOTES 1) This truss has been checked for unbalanced loading conditions. 2) This truss has been designed for the wind loads generated by 80 mph winds at 25 ft above ground level, using 7.0 psf top chord dead load and 5.0 psf bottom chord dead load, 100 mi from hurricane oceanline, on an occupancy category I, condition I enclosed building, of dimensions 60 ft by 38 ft with exposure B ASCE 7 -93 per UBC /ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are not exposed to wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33 3) Thls truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16 -B, UBC -94. 4) This truss has been designed with ANSI /TPI 1 -1995 criteria. 20-0-0 5 -3 -4 PLATES M20 Weight: 66 lb BRACING TOP CHORD Sheathed or 5 -0 -13 oc purlins. • BOT CHORD Rigid ceiling directly applied or 10 -0 -0 oc bracing. i 21 -6 -0 1-6-0 Scale = 1 :42.8 GRIP 185/144 EXPIRES 12/7/2001 „mono rr (425)-4884773 age Job B011Q100 ►► oo• cn �n LOADING (Psi) TCLL 25.0 TCDL 7.0 BCLL 0.0 BCDL 5,0 -1 -6 -0 1-6-0 nvi a urn er, ►►oo•Invl e, I russ T03 2 5x12 T: pe COMMON 5-7-0 5 -7 -0 6.00 FIT 5 -7 -0 5 -7 -0 3 3x8 4x12 II 1 h'tate Ottsets (X,Y): [2:U 4 y,a - z - s), L6:U 4 9,0 - 1 - 8f, (t3:U 6 U,0 - b - tiJ LUMBER TOP CHORD 2 X 4 HF No.2 BOT CHORD 2 X 8 DF 1950F 1.7E WEBS 2 X 4 SPF Stud /Std "Except* 4-8 2 X 4 HF No.2, 3-8 2 X 3 SPF Stud /Std 5 -8 2 X 3 SPF Stud /Std' 10 -0-0 4 -5 -0 9 8 10-0-0 4 -5 -0 REACTIONS (lb /size) 2= 7258/0 -5 -8, 6= 7148/0 -5-8 Max Horz2= 66(load case 4) FORCES (lb) - First Load Case Only TOP CHORD 1 -2 =25, 2 -3 =- 11611, 3-4= -7994, 4 -5= -7994, 5-6= -11611 BOT CHORD 2 -9= 10386, 8 -9= 10386, 7- 8= 10386, 6 -7 =10386 WEBS 3 -9 =3261, 4 -8 =6867, 5 -7 =3261, 3-8. 5-8= -3783 S 4x6 11 4 10x12 = Qty 1 Ply • 1 • 111 t • 111 - 14 -5 -0 4-5-0 in I 1I nil 14 -5 -0 4 -5 -0 o•tional I e n•us rtes, nc. rI 1ov 1 3x8 { 5 20 -0 -0 5 -7 -0 7 5x12 4x12 it 20 -0 -0 5 -7 -0 6 age 1 Scale = 1:41.6 SPACING 2-0-0 Plates Increase 1.15 Lumber Increase 1.15 Rep Stress Ina' NO Code UBC /ANSI95 Csl TC 0.90 BC 0.69 WB 0.98 DEFL in (loc) 1 /deft Vert(LL) -0.22 8 -9 >999 Vert(TL) -0.32 8 -9 >730 Horz(TL) 0.07 6 n/a 1st LC LL Min I /deft = 240 BRACING TOP CHORD Sheathed or 2 -9 -10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10 -0 -0 oc bracing. NOTES 1) This truss has been checked for unbalanced loading conditions. 2) This truss has been designed for the wind loads generated by 80 mph winds at 25 ft above ground level, using 7.0 psf top chord dead load and 5.0 psf bottom chord dead load, 100 ml from hurricane oceaniine, on an occupancy category I, condition I enclosed building, of dimensions 60 ft by 38 ft with exposure B ASCE 7 -93 per UBC /ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are not exposed to wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16 -B, UBC -94. 4) This truss has been designed with ANSI /TPI 1 -1995 criteria. 5) 2 -ply truss to be connected together with 0.131 "x3" Nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0 -9 -0 oc. Bottom chords connected as follows: 2 X 8 - 2 rows at 0 -7 -0 oc. Webs connected as follows: 2 X 3 - 1 row at 0 -9 -0 cc, 2 X 4 - 1 row at 0 -9 -0 oc. 6) Use USP MSH29 (With 10d nails into Girder & NA9D nails into Truss) or equivalent spaced at 4 -0 -0 oc max. starting at 2 -0 -0 from the left end to 18 -0 -0 to connect truss(es) T07 (1 ply 2 X 4 HF) to back face of bottom chord. 7) Use USP THD26 (With 16d nails into Girder & NA9D nails Into Truss) or equivalent spaced at 4 -0 -0 oc max. starting at 6 -0 -0 from the left end to 14 -0 -0 to connect truss(es) T07 (1 ply 2 X 4 HF) to back face of bottom chord. 8) Fill all nail holes where hanger is in contact with lumber. COAtfi111,t143)pa 1itand WARNING- Verify design parameters and READ NOTES ON THIS AND COVER PAGE BEFORE USE. This design is based only upon the parameters shown, and Is for an individual building component to be installed and loaded in the plane of the truss. Applicability of design parameters and proper incorporation of component is the responsibility of the building designer. The bracing requirements shown are for lateral stability of individual truss members. The bracing design is the responsibility of the building designer. Additional temporary bracing to insure stability during construction is the responsibility of the erector. For general guidance regarding fabrication, quality rnnlml alnrano rdalivanr ororldnn and hrnnlnn rnnandt ART.AII nualihi Stanrlarrl nRR.AQ Rrarinn Snarlerallnn 0 TE5 Weight: 205 lb GRIP 185/144 L XPIRES 12/7/2001 �VILLtf Luag1 (425) 488.1818 411 111111W (425) - 488.8773 Fax Job LOAD CASE(S) Standard 1) Regular: Lumber Increase =1.15, Plate Increase =1.15 Uniform Loads (pif) WARNING- Verify design parameters and READ NOTES ON THIS AND COVER PAGE BEFORE USE. This design is based only upon the parameters shown, and is for an individual building component to be Installed and loaded In the plane of the truss. Applicability of design parameters and proper incorporation of component Is the responsibility of the building designer. The bracing requirements shown are for lateral stability of Individual truss members. The bracing design is the responsibility of the building designer. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. For general guidance regarding fabrication, quality Type COMMON 2 2x3 \\ 4 -8 -10 4 -8 -10 Plate Offsets (X,Y): LOADING (psf) TCLL 25.0 TCDL 7.0 BCLL 0.0 BCDL 5.0 Continued on page 2 • 8 6 -6 -0 2 -8 -0 10x12 LUMBER TOP CHORD 2X4HFNo.2 BOT CHORD 2 X 8 DF 1950F 1.7E WEBS 2 X 3 SPF Stud /Std 'Except* 3 -8 2 X 4 SPF Stud /Std, 3 -7 2 X 4 SPF Stud /Std REACTIONS (lb /size) 1= 4587/0 -5 -8, 5= 4698/0 -5-8 Max Horz1=- 53(load case 3) FORCES (lb) - First Load Case Only TOP CHORD 1 -2= -6658, 2 -3= -6561, 3-4= -6561, 4 -5= -6658, 5 -6 =25 BOT CHORD 1 -8 =5956, 7 -8 =4252, 5.7 =5956 WEBS 2 -8= -182, 3.8 =3273, 3 -7 =3273, 4 -7= -182 5x8 = 3 8 -3 -6 3 -6 -11 s ug 9-2-0 2-8-0 Uty 7 10x12 = 2 2x3 // 4 WARNING Verify design parameters and READ NOTES ON THIS AND COVER PAGE BEFORE USE, This design Is based only upon the parameters shown, and is for an Individual building component to be installed and loaded in the plane of the truss. Applicability of design parameters and proper incorporation of component Is the responsibility of the building designer. The bracing requirements shown are for lateral stability of individual truss members. The bracing design is the responsibility of the building designer. Additional temporary bracing to insure stability during construction is the responsibility of the erector. For general guidance reaardlno fehri railnn n, lln, Ply ILUNU CLAS51C 0.tional) e n • us tes, nc. n ov 13 -0 -0 4-8 -10 13 -0-0 3 -10 -0 NOTES 1) This truss has been checked for unbalanced loading conditions. 2) This truss has been designed for the wind loads generated by 80 mph winds at 25 ft above ground level, using 7.0 psf top chord dead load and 5,0 psf bottom chord dead load, 100 mi from hurricane oceanilne, on an occupancy category I, condition I enclosed building, of dimensions 60 ft by 38 ft with exposure B ASCE 7 -93 per UBC/ANS195 If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are not exposed to wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16 -B, UBC -94. 4) This truss has been designed with ANSI /TPI 1 -1995 criteria. 5) 2 -ply truss to be connected together with 0.131 "x3" Nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0 -9 -0 oc. Bottom chords connected as follows: 2 X 8 - 2 rows at 0 -7 -0 oc. Webs connected as follows: 2 X 3 - 1 row at 0 -9 -0 oc, 2 X 4 - 1 row at 0 -9 -0 oc. 6) Use USP MSH29 (With 10d nails into Girder & NA9D nails Into Truss) or equivalent spaced at 4 -0 -0 oc max. starting at 3 -0 -0 from the left end to 11-0-0 to connect truss(es) T07 (1 ply 2 X 4 HF) to front face of bottom chord. 7) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard 1) Regular. Lumber Increase =1.15, Plate Increase =1.15 4x8 = PLATES M20 5 SPACING 2 -0 -0 Plates Increase 1.15 Lumber Increase 1.15 Rep Stress Incr NO Code UBC /ANSI95 CSI TC 0.22 BC 0.43 WB 0.99 DEFL Vert(LL) -0. Vert(TL) -0. Horz(TL) 0. 1st LC LL Min in (loc) I /defl 09 7 -8 >999 13 7 -8 >999 02 5 n/a I /deft = 240 Weight: 131 lb 14 -6 -0 1-6-0 6 GRIP BRACING TOP CHORD Sheathed or 4 -7 -10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10 -0 -0 oc bracing. age Scale = 1:28.0 185/144 I EXPIRES 12/7/2001 .m0 LNM".. (425) 488.1818 40v 11111110 411 (425)- 4888773 Fax i o russ 801/0100 T05 type COMMON LOAD CASE(S) Standard Uniform Loads (If) Vert: 1 -5 =- 667,5, 1 -3= -64,0, 3 -6= -64.0 WARNING- Verify design parameters and READ NOTES ON THIS AND COVER PAGE BEFORE USE. This design is based only upon the parameters shown, and is for an Individual building component to be Installed and loaded In the plane of the truss. Applicability of design parameters and proper incorporation of component Is the responsibility of the building designer, The bracing requirements shown are for lateral stability of individual truss members. The bracing design is the responsibility of the building designer. Additional temporary bracing to insure stability during construction is the responsibility of the erector. For general ouldance reaanilnn fahrtraunn niinllhr LONGCLA55IC lift (425)488-1818 (425) - 488.8779 73 Fax Job REACTIONS 1 -6- LOADING (psi) TCLL 25.0 TCDL 7.0 BCLL 0.0 BCDL 5.0 1 -6 -0 6-4-5 LOAD CASES) Standard SPACING 2 -0 -0 Plates increase 1.15 Lumber Increase 1.15 Rep Stress !nor YES Code UBC /ANS195 CSI TC 0.62 BC 0.84 WB 0.55 DEFL in (Ioc) I /defl Vert(LL) - 0.2612 -13 >999 Vert(TL) - 0.4412 -13 >978 Horz(TL) 0.12 10 n/a 1st LC LL Min I /dell = 240 LUMBER TOP CHORD 2 X 4 HF No.2 BOT CHORD 2 X 4 HF No.2 WEBS 2 X 3 SPF Stud /Std *Except* 5-12 2 X 4 SPF Stud/Std, 6-12 2 X 4 SPF Stud/Std 7 -12 2 X 4 SPF StudlStd , (lb /size) 2= 1426/0 -5.8, 10= 1315/0 -5-8 Max Horz2= 90(load case 4) FORCES (lb) - First Load Case Only ' : ! TOP CHORD 1 -2 =21, 2 -3= -2315, 3-4= - 4 -5= -2053, 5 -6= -1445, 6 -7= -1445, 7 -8= -2053, 8 -9= -2053, 9 -10= -2315 GOT CHORD 2 -13 =2049, 12 -13 =1686, 11 -12 =1688, 10 -11 =2049 WEBS 3 -13= -309, 5 -13 =346, 5 -12= -574, 6 -12 =920, 7 -12= -574, 7 -11 =346, 9 -11= -309 BRACING TOP CHORD Sheathed or 3 -1 -3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10 -0 -0 oc bracing. WEBS 1 Brace at midpt 5 -12, 7 -12 NOTES 1) This truss has been checked for unbalanced loading conditions. 2) This truss has been designed for the wind loads generated by 80 mph winds at 25 ft above ground level, using 7.0 psf top chord dead load and 5.0 psf bottom chord dead load, 100 mi from hurricane oceanline, on an occupancy category 1, condition I enclosed building, of dimensions 60 ft by 38 ft with exposure B ASCE 7 -93 per UBC /ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are not exposed to wind. The lumber DOL increase is 1.33, and the plate grip Increase is 1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16 -B, UBC -94. 4) This truss has been designed with ANSI /TPI 1 -1995 criteria. WARNING- Verify design parameters and READ NOTES ON THIS AND COVER PAGE BEFORE USE. This design is based only upon the parameters shown, and Is for an Individual building component to be installed and loaded in the plane of the truss. Applicability of design parameters and proper incorporation of component is the responsibility of the building designer. The bracing requirements shown are for lateral stability of Individual truss members. The bracing design is the responsibility of the building designer. Additional temporary bracing to insure stability during construction is the responsibility of the erector. For general guidance regarding fabrication, quality PLATES M20 Weight: 137 lb Scale = 1:72.7 GRIP 185/144 I EXPIRES 12/7/2001 ,,p V►VILI.r LWIf fR (425) 488-1818 4fik (425) - 488.8773 Fax 765 T russ . ,!B0111100 IT08 • • •,, V •: Iii - "oo•:nvi e um•er, ""oo•invi e, LOADING (psf) TCLL 25.0 TCDL 7.0 BCLL 0.0 BCDL 5.0 -1 -6 -0 1 -6 -0 LOAD CASES) Standard LUMBER TOP CHORD 2 X 4 HF No.2 BOT CHORD 2 X 4 HF No.2 WEBS 2 X 3 SPF Stud /Std Tru, , ype ROOF TRUSS CSI 0.62 BC 0.34 WB 0.15 DEFL Vert(LL) -0. Vert(TL) -0. Horz(TL) 0. 1st LC LL Min in (loc) I /defl 04 2 -6 >999 07 2 -6 >999 01 4 n/a I /defl = 240 SPACING 2-0-0 Plates Increase 1.15 Lumber Increase 1.15 Rep Stress Incr YES Code UBC /ANS195 6 -6.0 6 -6 -0 6 -6-0 6-6-0 REACTIONS (lb /size) 2= 575/0 -5 -8, 4= 575/0 -5 -8 Max Horz2=- 29(load case 3) Max Uplift2=- 12(load case 5), 4=- 12(load case 5) FORCES (lb) - First Load Case Only TOP CHORD 1 -2 =21, 2 -3= -499, 3-4= -499, 4 -5 =21 BOT CHORD 2 -6 =442, 4-6=442 WEBS 3 -6 =63 4x4 = 3 2x3 II 1 s • ug Qty 3 Ply 1 NOTES 1) This truss has been checked for unbalanced loading conditions. 2) This truss has been designed for the wind loads generated by 80 mph winds at 25 ft above ground level, using 7.0 psi top chord dead load and 5.0 psf bottom chord dead load, 100 mi from hurricane oceanline, on an occupancy category I, condition I enclosed building, of dimensions 60 ft by 38 ft with exposure B ASCE 7 -93 per UBC /ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are not exposed to wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16 -B, UBC -94. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 12 lb uplift at Joint 2 and 12 lb uplift at joint 4. 5) This truss has been designed with ANSI /TPI 1 -1995 criteria. WARNING Verify design parameters and READ NOTES ON THIS AND COVER PAGE BEFORE USE. This design is based only upon the parameters shown, and Is for an individual building component to be installed and loaded in the plane of the truss. Applicability of design parameters and proper incorporation of component is the responsibility of the building designer. The bracing requirements shown are for lateral stability of Individual truss members. The bracing design is the responsibility of the building designer. Additional temporary bracing to insure stability during construction is the responsibility of the erector. For general guidance regarding fabrication, quality a LONG C.LASSIL o • Clonal) n • us les, 13 -0 -0 6 -6 -0 13 -0 -0 6 -6 -0 nc. n ' ov PLATES M20 Weight: 39 lb 1 GRIP BRACING TOP CHORD Sheathed or 6 -0 -0 oc purllns. BOT CHORD Rigid ceiling directly applied or 10 -0 -0 oc bracing. 185/144 44��v��4�C (4 8 8.8773 1 Fax age 14 -6 -0 1 -6 -0 Scale = 1:29.2 [ EXPIRES 12/7/2001 1� Job No. : 00 -08 Location: Lo —16, Foster Heights illa, Washington Copyright 2000, SEGA Engineers STRUCTURAL CALCULATIONS LONG CLASSIC HOMES RESIDENTIAL PROJECT FOR THE Plan No. 472 F=E PY�_ November 29, 2000 RECEIVED CITY OF TUKWILA F EB 2 6 200? • PERMIT CENTER SEGA Engineers /Structural & Civil Consulting Engineers 22928 SE 312 ST (360) 886 - 1017 Black Diamond, WA 98010 SCOPE OF WORK SEGA Engineers was asked to provide a lateral loads analysis, shear wall design, review of major framing members, and drawing red -lines for a two story wood framed single family residence. The roof framing is primarily manufactured trusses, the floor framing is wood I- joists, and the foundation is typical concrete strip footings with a crawl space. The use of these calculations is limited to a single subdivision referenced on the cover sheet. The cover sheet should have an original signature in blue ink over the seal. Please contact SEGA Engineers for use at other sites. SEGA Engineers will use that degree of care and skill ordinarily exercised under similar circumstances by members of the engineering profession in this local. No other warranty, either expressed or implied is made in connection with our rending of professional services. For any dispute, claim, or action arising out of this design, SEGA Engineers shall have liability limited to the amount of the total fee received by SEGA Engineers. Questions regarding the attached should be addressed to SEGA Engineers. • / Greg Thesenvitz, PE SEGA Engineers SEGA Engineers /Structural & Civil Consulting Engineers 22928 SE 312 ST (360) 886 -1017 Black Diamond, WA 98010 LOADS z ROOF DL Roofing (Comp) 3.5 psf . 2 1 /2" OSB 1.8 U 2x @24" 3.5 too Insulation 1.1 w H 5 /8 " GWB 2.8 co u_ Misc. 1.5 •w 0 14.2 psf 2 J u. Q LL Snow 25 psf (115% Load Duration) to a Reduction, Rs -0.82 psf F w 6/12 pitch = 27 deg z � , I- O Total Roof Load 38.4 psf w i- w FLOOR 0 u DL Flooring 0.5 psf p I- 3 / Plywood 2.3 2 v 11 TJI @ 16" oc 2.8 P 5 /8" GWB 2.8 w Z , Misc. 1.5 U 9.9 psf per WALLS LL LL DL Siding 1 /2' Plywood 2x6 @16 "oc Insul t /2' GWB Copyright 2000, SEGA Engineers Project :H #472 Residential 40 psf DECKS DL 2 x Decking 4.3 psf 2x10 @16 "oc 2.8 Misc 1.5 8.6 Residential 40 psf 3.0 1.5 psf 1.7 0.6 2.2 • Job No. 00 -082 By: GAT Checked Date: 11 /28/00 Sht 1 of Total Floor Load 49.9 psf Total Deck Load 48.6 psf 9.0 psf z SEGA Engineers PROJECT L c4.( 4- 4 7 2 / Structural & Civil Consulting Engineers JOB NO, 0 0 _ d $1 FIGURED BY 44 22928 SE 312th ST • Black Diamond, Washington 98010 (360) 886 -1017 • Fax (360) 886 -1016 CHECKED BY DATE { / 1/4.t., SHEET Z�OF upper floor framing beam and garage laundry SEGA Engineers , Project l am ' ; #472 /Structural & Civil Consulting Engineers Job No. 00 -081 By: GAT ' 22928 SE 312 ST (360) 886 -1017 Black Diamond, WA 98010 Checked Date: 11/28/00 Sht. .3 LATERAL LOADS SEISMIC . WIND For W: Maximum Base Shear, V = 2.5 C I W where, Design Wind Pressure, p = C C q where, C = 0.62 = 0.67 = 0.72 Therefore, Wroot = WAoar = R Ca = 0.36 Zone 3, S Table 16 -Q I = 1 Table 16 -K R = 5.5 Table 16 -N W = Seismic Weight Design Base Shear , V = ( .164) (68 kip) = 11.1 kip E = ( 1.00) (11 kip) = 8.0 kip 1.4 0 -15ft 20 ft 25 ft (40ft) (43ft) (16psf)+ (2) (40ft+ 43ft) (4.Oft) (9psf) = 33 kips (40ft) (41 ft) (14psf)+ (2) (40ft+ 41ft) (8.Oft) (9psf) = 35 kips W total = 68 kips Cq = 1.3 Method 2 qs = 16.4 psf 80 mph I = 1 P0-15 = ( 0.62) (1.3) (16.4 psf) (1) = 13.22 psf P20 = ( 0.67) (1.3) (16.4 psf) (1) = 14.28 psf P25 = ( 0.72) (1.3) (16.4 psf) (1) = 15.35 psf Wind Loads Govern for Lateral Design - Each Way Sect. 1630 Eq. 30 -5 Eq. 30 -1, Sect. 1630.1.1 Eq. 20 -1, Sect. 1620 Exposure B Table 16 -G Design Base Shear: (Wind) Vf /b (40ft) (10ft) (13.2psf) + (40ft) (5ft) (14.3psf) + (40ft) (5ft) (15.4psf) Vs/s= (48ft) (10ft) (13.2psf) + •(38ft) (5ft) (14.3psf) + (14ft) (5ft) (15.4psf) Table 16 -H Figure 16 -1 = 11.2 kips = 10.1 kips Copyright 2000, SEGA Engineers SEGA Engineers / PROJECT / Structural & Civil Consulting Engineers JOB NO. Ot, — p 61 22928 SE 312th ST • Black Diamond, Washington 98010 (360) 886 -1017 • Fax (360) 886 -1016 CHECKED BY shear wall design SEGA Engineers / PROJECT / Structural & Civil Consulting Engineers JOB NO. 0 _ 22928 SE 312th ST • Black Diamond, Washington 98010 (360) 886-1017 • Fax (360) 886-1016 CHECKED BY shear wall design SEGA Engineers / PROJECT / Structural & Civil Consulting Engineers JOB NO, 00 - 001 22928 SE 312th ST • Black Diamond, Washington 98010 (360) 886-1017 • Fax (360) 886-1016 CHECKED BY shear wall design SEGA Engineers / PROJECT L / Structural & Civil Consulting Engineers JOB NO, acy FIGURED BY f 7 r 22928 SE 3I2th ST • Black Diamond, Washington 98010 (360) 886-1017 • Fax (360) 886-1016 CHECKED BY DATE SHEET OF shear wall design bonus room option SEGA Engineers PROJECT / Structural & Civil Consulting Engineers 22928 SE 312th ST • Black Diamond, Washington 98010 (360) 886 -1017 • Fax (360) 886 -1016 CHECKED BY EIC- 144- Copyright 2000, SEGA Engineers JOB NO, Ot,, ocal F IGURED BY(4 DATE ey,,p SHEET 8 OF g shear wall plan Mark Minimum Sheathing (1) Sheathing Nailing (1) Sole Plate Nailing Anchor Bolts (3) Remarks / i> Min. 3 /8 ' T1 -11 or OSB 6d @ 6" o.c. 16d @ 8 "o.c. 5/8" @ 60" o.c. Qall = 195 plf E. 1 /2 OSB or 8d @ 4" o.c. N/A 5 /8' @ 32" o.c. Qall = 350 plf CDX 1 /2' OSB or 8d @ 3" o.c. N/A 5 /8 @ 19.2" o.c. QaII = 450 plf / CDX Use 3x studs at abutting panel edges and stagger nails SHEAR WALL SCHEDULE Notes: 1) All walls designated " are shear walls. Exterior walls shall be sheathed with rated sheathing (24/0, OSB or CDX) and nailed at all panel edges (Blocked) per schedule (uno). Nailing at intermediate framing to be at 12" oc. Nailing not called out shall be per UBC Table 23- II -B -1. 2) Holdowns and other framing hardware by Simpson or equal to be used per plan. Ends of shear walls shall use double studs minimum (UNO). 3) Use minimum of (2) bolts per sill piece with one bolt located not more than 12" nor less than 5" from each end of the piece. Embed bolts a minimum of 7" into concrete. Washers to be minimum 2" x 2" x 3 /18 ' . 4) See NER -272 for alterante nailing / staples. 114? 9at+vmar nrx 4 ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 S 145 STREET Original Plan Submittal Response to Correction Letter # DATE: 11 -22 -02 Response to Incomplete Letter # X Revision # 1 After Permit Is Issued DEP ' TMENTS: Builu Divis Public { orkilio 12 Uzi L 1 RMi � COORD COPY PLAN REVIEW /ROUTING SUP rl '^la 12-o Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete (f Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROVING: Please Route g Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 1 r r 6 ' k 11 -z(p.0L Planni Division Q Permit Coordinator DUE DATE: 11-26-02 Not Applicable ❑ DUE DATE: 12-24 -02 DATE: z W QQ • � JU O 0 N J • = f- W O 1 < CO I I- la Z 0 Z 0 0 I-- W W H0 LLO .. z W U FL: I .... . z City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. //- Z / —o 2 Plan Check/Permit Number: ta5/ Date: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # / after Permit is Issued Project Name: J AiVr) Project Address: 109 , o `(ge a to sr Contact Person: G• ,,w Phone Number: f 4.5 * -- e l e 44465764. Summary of Revision: 6 • iz 6 • APoi5t> Foc- 4oP.a.z.0147 PSetr - -iVEf CITY OF TUKWILA NOV 2 1 2002 PPR V1 ;' rs:AtTFP Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Dr Entered in Sierra on /f a / -0 Z— . It.SANVY 4 .N 0 9,/Mh•1•Nx ^ rt.ewrW••∎ .�2• +M'•'r�♦Kalrt; V.VYRt�A:f; R�+u4rvMrviV r•.nv�� •• ∎•,,.. ,. ,,... 08/30/00 z ~ • w J O O 0 • 0 w = H U) LL W O 2 u-Q = • a w z Z O w U � O 5 o ff w w L r.z w U ( I ) o � z ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS — LOT 15 SITE ADDRESS: 4806 S 145 STREET DATE: 11 -22 -02 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete APPROVALS OR CORRECTIONS: Approved Notation: Akt REVIEWER'S INITIALS: Documents/routing slip.doc 2.28.02 .tf PLAN REVIEW /ROUTING SLIP Approved with Conditions Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator ❑ Incomplete DUE DATE: 11-26-02 DATE: , t 'Z Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 12 -24 -02 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z w cc _1 U CO W • = J I— W O = • a • LU Z = I— O Z I— W U � O N O t-- W I - .• Z N O -- O I DEPARTMENTS: Building Division ❑ Public Works ❑ Complete ❑ Documentshouting slip.doc 2-28-02 APPROVALS OR CORRECTIONS: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 S 145 STREET DATE: 11 -22 -02 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Is Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route ❑ Stru ral Review Required ❑ No further Review Required REVIEWER'S INITIALS: G� DATE: \ \\ 2(,\ c 7 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Planning Division Permit Coordinator DUE DATE: 11-26-02 Not Applicable ❑ DUE DATE: 12 -24 -02 DATE: z w ce J U 00 W = J - wO LL Q • a = Z I— F- O Z F- LU • W O • N O I-- W W F- H W Z U= O Z PLAN REVIEW /ROUTING SUP ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 S 145 STREET DATE: 11 -22 -02 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Is Issued DEPARTMENTS: Building Division ❑ Fire Prevention ❑ Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2.28.02 Incomplete TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: REVIEWER'S INITIALS: DUE DATE: 11-26-02 DATE: Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: .X DUE DATE: 12 -24-02 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z ~ w ee l 6 U 00 N J H U) IL WO 1Q =a I-- in Z = 1— O Z I- W W U� 0 - 0 1-- W W H-- 111 Z — x O~ z ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS — LOT 15 SITE ADDRESS: 4806 S 145 STREET DATE: 11 -22 -02 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ PLAN REVIEW /ROUTING SLIP Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator ❑ Incomplete DUE DATE: 11 -26-02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route s e Structural Review Required ❑ No further Review Required ❑ / REVIEWER'S INITIALS: CAW\ DATE: 1 / Zip /0 L APPROVALS OR CORRECTIONS: Approved ( Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: / DATE: /L fV02 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 sn. 4 .41. • ••v,e' DUE DATE: 12-24 -02 w z w a Q : D (,) 00 0 W J 1.— W0 co J I W z = F- 0 Z 1— W W U 0 0 I— W W • 0 O Z W O - O ~ z DEPARTMENTS: Building Division TUES /THURS ROUTING: Please Route Documents/routing slip.doc 2 -28.02 APPROVALS OR CORRECTIONS: PERMIT COORD COPY ERMIT COORD CO -"( PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 SOUTH 145 STREET Original Plan Submittal Response to Incomplete Letter # XX Response to Correction Letter # DATE: 04 -08 -02 Revision # After Permit Is Issued Structural Review Required ❑ No further Review Required I112P • c,PL y .02. ❑ Fire Prevention ❑ Planning Division Pu lick orks Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [ Incomplete ❑ Comments: DUE DATE: Not Applicable 0 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: 4 -09 -02 REVIEWER'S INITIALS: DATE: DUE DATE: 5-07-02 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z w ce J O 0 0 0 J = I-- W O 2 QQ LL Q = H F- O z W U O O N O I-- W W L I O .. z W = O z City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 { Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: "Y'""�� Plan Check/Permit Number: D02-051 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued Project Name: FOSTER HEIGHTS — LOT 15 Project Address: 4806 South 145 Street Contact Person: Charles Prib Phone Number: Summary of Revision: APR 0 8 2002 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ` ❑ Entered in Sierra on PERMIT CENTER 03/19/02 March 19, 2002 Charles Prib 14205 SE 255th Place Kent, WA 98042 Dear Mr. Prib: city of Tukwila Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Number D02 -051 Foster Heights — Lot 15 4806 South 145th Street This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Division and Public Works Department. At this time, the Building Division and Fire Department have no comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206)431 -3670. Sincerely, Brenda Holt Permit Coordinator encl xc: File No. D02 -051 '1u:'.2.4.114 i :l+N.W4y.ry.Y.vT� Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 APPROVALS OR CORRECTIONS: Approved l Notation: Documents/routing slip.doc 2 -2802 PLAN REVIEW /ROUTING SUP ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 SOUTH 145 STREET Original Plan Submittal Response to Incomplete Letter # XX Response to Correction Letter # 1 DATE: 04 -08 -02 Revision # After Permit Is Issued DEPARTMENTS: Building Division ❑ Fire Prevention ❑ Planning Division Public Works ❑ Structural ❑ Permit Coordinator DUE DATE: 4 -09-02 DUE DATE: 5-07 -02 `l1Cf /o,' ›r1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1 Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Not Approved (attach comments) ❑ Approved with Conditions 1,. r OAf✓��' key. Si{Z Y YJA^ 6/40(, 1' ?/02- REVIEWER'S INITIALS: t.,(3 , DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z • • 6 JU O 0 LLI J CD Li. w 0 gQ co = a . I- w Z = E- Z I- LU La U (-9- 0 I- w W H 1- .. w = I 0 Z DEPARTMENTS: Building Division Public Works Complete ❑ REVIEWER'S INITIALS: Documentshouting sllp.doc 2.28.02 APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS — LOT 15 SITE ADDRESS: 4806 SOUTH 145 STREET DATE: 04 -08 -02 Original Plan Submittal Response to Incomplete Letter # XX Response to Correction Letter # 1 Revision # After Permit Is Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ■ (,] Structural Review Required ❑ No further Review Required ❑ 41 5 DATE: ' 9 /02.- Approved ❑ Approved with Conditions It Not Approved (attach comments) ❑ Notation: eEStDrb F'SEMEsOr AL bleb Pj@,j,4& m F.7414 C S4C IU 0rr DATE: 4/ie/o J ❑ Planning Division ❑ ❑ Permit Coordinator ❑ DUE DATE: 4 -09-02 Not Applicable ❑ DUE DATE: 5-07 -02 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z ~ W ct Q g J U 0 W CO ILI J= W° � D = d � Z � 1-- Z I— D o O - O I- W W L I O .. W co O ~ z DEPARTMENTS: Please Route Approved Approved 1PRROUTE.DOC 5/99 PERMIT COORD CCF' PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 SOUTH 145 STREET X Original Plan Submittal Response to Correction Letter #, DATE: 02 -26 -02 Response to Incomplete Letter # Revision # After Permit Is Issued Buildilig bivisio 3.19 Public W ? u&L d rks 114 •(.•D2 TUES /THURS ROUTING: Fire Prevention AlAW 3 • ti Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [0 Incomplete Comments: Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved with Conditions REVIEWER'S INITIALS: DATE: (1t)Y 41.iiktiii 3 • ( CORRECTION DETERMINATION: Approved with Conditions Ot, Planning Division dZhil4 2'tb� Permit Coordinator DUE DATE: 02-28-02 Not Applicable No further Review Required DUE DATE 03 -28 -02 Not Approved (attach comments) Not Approved (attach comments) REVIEWER'S INITIALS: DATE: n DUE DATE FA' PPevie Z � QQ 2 J O 00 W J F. M LL w L a cn = w z = w w c oI W tL O w z U = O~ z ACTIVITY NUMBER: D02 - 051 DATE: 02 - - PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 SOUTH 145 STREET X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Comments: TUES /THURS ROUT NG: Please Route ,' Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved REVIEWER'S INITIALS: Approved \PRROUTE.DOC 5/99 Approved with Condition CORRECTION DETERMINATION: REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 02-28-02 Not Applicable No further Review Required DATE: DUE DATE 03 -28 -02 DUE DATE Approved with Conditions Not Approved (attach comments) DATE: atAct 14 tett (1 t Ok. 5 kees¢- VI( Not Approved (atta h com ents) I I DATE: g z w J U 00 LO J wO 2 :D LL < _ d F- _ z � I-0 Z �- U � O - 0 I- W W H O .. z U = OF" z Ni PERMIT NO.: bOZ `05I BUILDING PERMITS INSPECTIONS ❑ 1 Progress Inspection Status ❑ 2 Pre - construction ❑ 3 Investigation ❑ 4 OK to Occupy ❑ 5 Remove Stop Work Order ❑ 6 Follow -up ❑ 7 Pre -Move Inspection ❑ 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ 70 NLEA Inspection /Modular Struct ❑ 71 Mobile Home Tie Down Insp ❑ 72 Marriage Lines 90 Resteel 95 Footing Drains 100 Foundation Footings 200 Foundation Walls ❑ 250 Foundation Insulation ❑ 300 Concrete Slab /Slab Insulation 350 Crawl Space 400 Shear Wall Nailing 450 Plywood Wall Sheathing 500 Roof Sheathing Nailing 525 Plywood Deck Nailing 550 Exterior Wall Sheathing 600 Masonry Chimney 610 Chimney Installation/All Types 700 Framing 750 Roof /Ceiling Insulation 800 Floor Insulation 801 Wall Insulation 802 Exterior Roof Insulation 803 Glazing Inspection ❑ 815 Lighting and Controls 0 , 900 Suspended Ceiling 1000 Interior Wallboard Fastening ❑ 1001 Exterior Wallboard Fastening ❑ 1110 Pre -Move Inspection ❑ 1115 Motor Inspection ❑ 1120 Pre -Demo ❑ 1140 Pre - reroof 1400 Final -Fire 1700 Final- Building ❑ 1900 Final- Reroof ❑ 3100 Site Visit ❑ 4000 Special- Concrete ❑ 4001 Special -Bolts in Concrete ❑ 4001 Special - Mom/Resist Conc Frame ❑ 4003 Special -Reinf Steel Prestress ❑ 4004 Special - Welding ❑ 4005 Special- High - Strength Bolting ❑ 4006 Special - Structural Masonry ❑ 4007 Special -Reinf Gypsum Concrete ❑ 4008 Special- Insulating Conc Fill ❑ 4009 Special -Spray Fireproofing ❑ 4010 Special - Piling, Piers, Caissons ❑ 4011 Special - Shotcrete ❑ 4012 Special- Grading, Excav /Fill ❑ 4013 Special- Retaining Wall ❑ 4014 Special- Panels ❑ 4015 Special -Smoke Control System TENANT NAME: /10‘5" vis LDT /s CONDITIONS 10001 No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & I 10004 All mechanical work shall be under separate permit 10005 All permits, insp records & approved plans available ❑ 10006 All structural concrete shall be special inspected ❑ 10007 All structural welding shall be done by WABO certified inspector ❑ 10008 All high - strength bolting shall be special inspected ❑ 10009 Bolts installed in concrete shall be special inspected ❑ 10010 When special inspection is required...notify Tukwila Building Division ❑ 10011 The special inspector shall submit a final signed report ❑ 10012 Any new ceiling grid and light fixture installation ❑ 10013 Partition walls attached to ceiling grid _1k 0014 Readily accessible access to roof mounted equipment 10015 Engineered truss drawings & calcs shall be on site 10016 Any exposed insulation backing material shall have ❑ 10017 Subgrade preparation including drainage, excavation ❑ 10018 A statement from the roofing contractor verifying fire X 10019 All construction to be done in conformance retardant class of roof w /approved plans ❑ 10020 Structural observation shall be provided for this project ❑ 10021 All food preparation establishments must have King Co ❑ 10022 Fire retardant treated wood shall have flame spread of 10023 Notify Building Division prior to placing any concrete ❑ 10024 All spray applied fireproofing shall be special inspected ❑ 10025 All wood to remain in placed concrete shall be treated 10026 All structural masonry shall be special inspected 10027 Validity of Permit ❑ 10028 Rack storage requires separate permit 10030 No occupancy of building until final insp by Bldg Div ❑ 10031 Comply with requirements of TMC 16.04 ❑ 10032 Remove all weeds, concrete, stone foundations, flat concrete ❑ 10034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ 10035 Contact PW Div to obtain insp for water /sewer connect ❑ 10036 Manufacturers installation instructions required on site ❑ 10038 A C of 0 will be required for this permit ❑ 10039 Final approval for all TI w /in the limits of the SC Mall ❑ 10040 All construction noise to be in compliance with 8.2 TMC ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate ❑ 10044 Water heater shall be anchored ❑ 10045 Reroof ❑ "Anchoring — All new construct and substantial improvement shall be anchored to prevent tlotation" Plan Reviewer: Permit Tech: Date: 02 Date: 3 • Lq -01 6.MKT �ilfC'•. :+ill:�+,lf'W+vwua yTC:1tl.V11 -�� ^v Z ~ • W 6 O 0 CO W J 1 � u- W OO • F tL H = . Z � II— 0 Z 111 I— uj • 0 O N O H W W I LL O .. Z W U 0 I- Z ACTIVITY NUMBER: D02 - 051 DATE: 02 - - PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 SOUTH 145 STREET X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter #, _ Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works Complete Please Route Approved 1PRROUTE.DOC 5/99 TUES /THURS ROUTING: APPROVALS OR CORRECTIONS: (ten days) Approved ri PLAN REVIEW /ROUTING SLIP REVIEWER'S INITIALS: CORRECTION DETERMINATION: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Approved with Conditions Structural Review Required f( Incomplete n Not Applicable n Comments: Planning Division Permit Coordinator DUE DATE: 02-28 -02 No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE 03 -28 -02 Not Approved (attach comments) DATE: Approved with Conditions n Not Approved (attach comments) REVIEWER'S INITIALS: DATE: DUE DATE ti z ~ w QQ • � J O O 0 U) o J = 1-- w O U O N cn W 1- = UO w z U= 0 I- z ACTIVITY NUMBER: D02 -051 PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 SOUTH 145 STREET X Original Plan Submittal Response to Correction Letter # DATE: 02 -26 -02 Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works Complete TUES /THURS ROUTING: Please Route Approved REVIEWER'S INITIALS: \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved with Conditions lfp i CORRECTION DETERMINATION: Approved n Approved with Conditions n REVIEWER'S INITIALS: Planning Division 4 ;)? Permit Coordinator DUE DATE: 02-28-02 Incomplete n Not Applicable No further Review Required Comments: DATE: DUE DATE 03 -28 -02 Not Approved (attach comments) DK DATE: 0 40 7_, DUE DATE Not Approved (attach comments) DATE: z ~ w -J C.) U O co o co Lu J = H co u_ w O 2 < I I- _ z �. I- O Z w U � 0 O -- w I- w O z City of Tukwila Department of Community Development Steve Lancaster, Director PLANNING DIVISION COMMENTS DATE: February 28, 2002 APPLICANT: Long Classic Homes RE: Foster Heights, Lot 15, D02 -051 ADDRESS: 4806 South 145 Street Please review the following comments listed below and submit your revisions accordingly. If you have any questions on the requested revision, Carol Lumb is the planner assigned to the file and can be reached at 206 - 431 -3661. 1. The site plan shows the fireplace as cantilevered into the side yard setback, which is not consistent with what the construction drawings show (page 3/11). The fireplace may not extend into the 5 -foot side yard setback. Please correct the site plan to show the correct location of the fireplace. c:\mydocs \generai\2002- memos \DO2 -051. doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 - 3665 Steven M. Mullet, Mayor t . ACTIVITY NUMBER: D02 - 051 DATE: 02 - - PROJECT NAME: FOSTER HEIGHTS - LOT 15 SITE ADDRESS: 4806 SOUTH 145 STREET X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route (K Structural Review Required n No further Review Required REVIEWER'S INITIALS: V DATE: 2 -2 7 (V, APPROVALS OR CORRECTIONS: (ten days) Approved Approved \PRROUTE,DOC 5/99 PLAN REVIEW /ROUTING SLIP REVIEWER'S INITIALS: Approved with Conditions CORRECTION DETERMINATION: Fire Prevention Structural Incomplete L S J Approved with Conditions REVIEWER'S INITIALS: n Planning Division Permit Coordinator DUE DATE: 02 -28-02 Not Applicable DUE DATE 03 -28 -02 Not Approved (attach comments) DATE: 3 /t/ 2'- )Lc'.,. Not Approved (attach comments) DATE: DUE DATE I I z w CL 6 J U 0 U, 0 WI J 1- WO W co I w Z = zI- W U � O — O I- W W H H 9--O .z w O F- z 1 q PUBLIC WORKS DEPARTMENT COMMENTS z J- W re g DATE: March 6, 2002 -J o NO PROJECT: FOSTER HEIGHTS - LOT 15 co PERMIT NO: D02 -051 w 0 ga . PLAN REVIEWER: Contact Joanna Spencer at (206) 433 -0179 if you have any questions u_ regarding the following comments. co a 1-w z 1- 0 Z I- w w 1) Please add a note "Residence on lot 15 shall be provided with a sprinkler system. Contact o i— Tukwila Fire Department @ (206) 433 -1859 for coordination ". The above requirement is z 0 part of Foster Heights final plat L2000 -026 approval, see note 12 on plat sheet 2 of 3. IL. o z 2) A larger size water meter shall be required, please coordinate with Water District #125 at v (206) 242 -9547. 3) Grated drain channel at the end of the driveway shall be moved to the North and installed outside the existing 10 -ft wide utility easement. Make sure the driveway is designed and sloped so that drainage from the driveway does not flow into the existing road surface. Driveway slope shall be a maximum of 15%. Show driveway width. 4) Proposed rockery shall be build per attached City of Tukwila Detail RS -5. Please show rockery drainage system and how it ties into the existing /proposed drainage system for lot 15. Please note, that a specific distance from the face of rockery is required where no structure, roadway or parking can be located. If the above distance can not be maintained, a structural retaining wall shall be designed and constructed. This requirement applies to all the rockeries shown on the plan. 5) Please cloud all new revisions. Enter the above revisions in the revision block on your plan including revision number, date and revision description. 6) Please have your geotechnical engineer, Earth Consultants Inc., review the revised plan and submit a new Geotechnical Review letter of revised plan for lot 15. .sgaZA+n. 01+..ff,ar,.n..,p r >:e...,,.. �.,,,.•„n ........ • .......,,„....,. ...,.. M..•....:. w-...,, .,,...,.: /W4l, z Revision No. Date ! Received I 1 Date Received Date 1 Staff Issued I Initials i Staff Date -Staff i Initials Issued Initials .1 I //- Z-/-aZ. Summary or Revision: i Summary of Revision: ife C ....id-r-o......... a' Received By: p_ Revision No. 1 Date ! Received I 1 Staff Initials Date 1 Staff Issued I Initials I I I Summary of Revision: Summary or Revision: Received By: . - Received By: . Revision No. • Date Received Staff Initials Date Issued Staff Initials . . .._. I Summary of Revision: Summary or Revision: Received By: Revision No. Date Received Staff 1 Initials Date Issued Staff Initials . . .._. I Summary or Revision: Received By: Revision No. Date Received Staff Initials Date Staff - Issued Initials Summary or Revision: Received By: . . PROJ Ea NAME: 4 --Z or Site Address: 4/9 /9.r Sr REVISION LOG P ERM I \10• . Z,2 - 1 Original Issue Date: (please print) (please print) (please print) (please print please prin APR -18 -2002 THU 08:28 AM DOL 1 STATE OF WASHINGTON LONG CLASSIC HOMES, LTD. 1624 PIONEER ST ENUMCLAW WA 98022 REGTSTERED TRADE NAMES: LONG CLASSIC HOMES JML HOMES INC. ORGANIZATION TYPE DOMESTIC PROFIT CORPORATION 'FAX NO, 360 664 9635 MASTER LICENSE SERVICE REGISTRATIONS AND LICENSES EDIFIED BUSINESS ID 4; 601 452 910 BUSINESS ID #: 001 EXPIRES : 03-31-2003 »OMESTIC PROFIT CORPORATION • RENEWRD BY AUTHORITY OP SECRP, ARY OF STATE 4 Signature I - REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CCO1 'LONGCHL05409 11/01/2002 EFFECTIVE. DATE.. 09/29/1995 LONG CLASSIC HOMES LTD,..: 1624 PIONEER: STREET ENUMCLAW WA: 98022 P, 01 .• z re W .' aa W ,J U O 0 co - H CO U- W 0 < = • d I- W I Z Z � W 0 O - O I-- W • W H r- .. z . -- 0 z Return Address 20010803000206 CITY OF TUKWILA Office of the City Clerk 6200 Southcenter Blvd Tukwila, WA 98188 (206) 433 -1800 Document Title(s). Parties: Other: CITY OF TUKWILA DOCUMENT RECORDING COVER SHEET UNDER6ROUNDIN City of Tukwila, WA 6200 Southcenter Boulevard Tukwila, WA 98188 Last First TRIDOR I nu, Company Name (if bu mess) City State Zip Legal Description: LDt _' ti � � Me�� •..l>r. • at L2000 -026 r ordi n 3 go. 2.001070 • • • o 7. Assessor's Property Tax Parcel/Account Number(s): 261000 - 0010 261000 -0020 20010803000206 Lot No. 'l'ax Parcel No. UND + RGROUNDING AGREEMENT WAIVER TO UNI ERGROUNDING ORDINANCE OBLIGATION FOR FUTURE UNDERGROUNDING The proposed system upgrade at Poster Ileights 16 -lot subdivision development, File No L2000 -026, at 47 ' Ave South and South 145'' Sltect requires undergroundtng per Ordinance 486, 924 and 1321 ALOI1& 5. I44,th a'TQEET - 5EE fflrACHMEN't A, In compliance with the requnements of Oidmance No 1607 the property owner of this single- tanitly development has demonstrated application of the Underground Ordinance will create undue hat dship if cart led out as part of the development The Owner is obligated to participate in funding luture undergroundmg improvements for their proportionate share o - said undeigiounding fronting their property Furthermore, if the L I D /U L I D procer.s is used to carry out the construction of this undergroundtng, the Owner waives the right to protest L 1 D or U L I D formation for this undetgrounding Owner reams the right to contest the method of calculating assessments in such L 1 D and the amount thereof to be levied against the Owner's subject pt operty, and other propel ty owned by Owner which would be within such L I D This Agteetnent shall be recorded by the City Cleik with the King County Auditor as required by Chapter 35 91 RCW and the cost of said recording will be paid by the City This Agreement shall be binding upon the parties, their respective heirs, legal repiesentattves, assignees, transferees and successors 'I'his Agreement runs with the land APPLICANT; Applicant (Signature) Street Address STATE OF WASHINGTON County of kIVkG On this day personally appeared before me &H to be known to be the individual(s) described in and who executed the within and foregoing instrument, and acknowledged tha to she /they signed the same a ter /their free and voluntary act and deed, for the uses and purposes therein mentioned Given under my hand and official seal this 1 2 day of -9L CITY OF TUKWILA fr omuz,.. Works Director Date City, State, Zip Signature (Ykt b Print Name NOTARY PUBLIC IN AND FOR THE STATE attachment a site plan Balance Due: $ /948 Need Current Contractor Registration Card: Need to Enter Contractor Information in Sierra: . Balance Due: $ /948 Need Current Contractor Registration Card: Need to Enter Contractor Information in Sierra: ALL BE DOUBLE G A FD AND COMPLY 1994 STAT OF WASN ENERGY CODE ' TREATED WOOD /WEA MEN :PER ` UPC SEC 2317 STD, STM1 - `RECEIVED detail wall section s-1 general notes lower floor plan upper level plan foundation plan optional bonus room plan bonus room floor framing lower floor framing upper level floor framing RECEIVED CITY OF TUKWILA FEB 2 6 ZOOZ PERMIT CENTER Upper Roof 1300 SQ FT/3O0.4.34SQ FT. 6627SQ IN - REQUIRED -'`'PROVIDE 20-3 HOLE SCREENED VENT macs (.14 SQ IN) * 300 Sq IN 0-9 x 7 ROOF VENTS (S0 SQ IN) MI 400 SQ IN . ; 2 BASE END VENTS 12x24 (140 ha) .. a 280 SQ IN Amor Roof FT /30O.1.00 SQ FT. 270 SQ IN - REQUIRED : k IDE 14-3 'SOLE SCREENED VENT BLACKS (.14 !Q IN) a IN Sq IN I, . ` 4-9 x 7 ROOF VENTS (SO SQ IN) a 200 SQ IN t. au, WTI M SNAIL BE I 2 NEN /P NIB AN MONS APPIIOVED DESIGN sEM 4'. }AML METAL. WOOERS SHALL BE " STRONG • TIE !MONIES OR EQUAL . TOTAL PROVIDED • NO SQ IN lower level room framing upper roof framing roof framing bonus room option nts, changes and variations from plans and specifkations during construction roof venting shear wall schedule section a-a ALL WALLS ° Uti Z HATED" °" ARE Smolt WALLS. EXTERIOR WALLS 4 ' SHALL OE SHEATHED Was RATED SHEATHING (24/0, ON Olt COX) AND NAILED AT ALL PANIC. EDGES (BLOCKED) PER SCHEDULE (UNO). - #FLAILING AT INTERMEDIATE FRAMING TO BE AT 12" o.c. NAILING NOT CALLED OUT SHALL U PER UK TABLE 2341 -R-1. HOLDOWNS AND met FRAM HARD RARE BY SIMPSON OR EQUAL BE PElt . O ING F � � W USE DOUBLE 9 ",. STUDS MINIMUM (UNO). - 3.) USE MINIMUM OF (2) OOL.TS PER SILL PIECE WITH ONE BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN S' FROM EACH END OF THE PIECE. memo BOLTS A MINIMUM OF r IM10 CONCRETE. L141.) SE! NER - 272 FOR ALTERNATE NAILING / STAPLES. Is r t, e e.6r5 1- it74 ) • aMlr,"d ti7F:Tha Zs:r.,•• 4114•44/11” ae- :assraru�nad CRAWLSPACE VENTILATION MIN NET AREA 1 SQ. FT FOR EACIL ISO SQ FT OF FLOOR AREA OPENINGS TO BE PLACED AS CLOSE TO CORNERS AS PRACTICAL AND SHALL PROVIDE OtOSS VENTILATION ON AT LEAST no) oprosna SIDES, UDC SEC - 2313.7. * GENERAL NOTES • 4 ' ATTIC VENTEIATION. 1/150 OF AMC AREA OR 1/300 IF HiLF IS IN SOFFIT AND HALF IS 3' ABOVE PLATE LBW WIC SEC U05.3 . / AMC ACCESS MIN 22"X 30' WITH PUN 30" HYADROOM IN ROOMS NOT PROVIDED wrno °MAIM WINDOWS OF 1120 OF FLOOR AREA OR 3 SQ FT , MECHAIVICAL VENTILATION SYSTEM, CAPABLE OF PROVIDING AIR 011ANGES PER HOUR SHALL BE PROVIDED UDC SEC. 1203. • . ouTsi VEPIT FANS • ■:14 . , RANGES ,., /OVENS !IE EPITE_ TO AND FINISHED SEC 302. 4 (3) AND TABLE 34 UBC. gARAGE AND GARAGE AND HOUSE OCCUPANCY SEPARATION MIN 1 HR TAPED. BASEMENT SUPPORTS TO BE I HR TYPE 'X" OR EQUAL GYPSUM TILE FOR SHOWER SHALL BE 6' ABOVE DRAIN WM1 WATER RaszsrANT moan. EGRESS IN EVERY SLUMP ROOM SHALL HAVE A MIN NET CLEAR OPENING OF 5.7 SQ.FT., THE MIN NET CLEAR OPENING HEIGHT SHALL BE 24" MIN , NET CLEAR OPENING WIDTH DIM. OF 20" , OOTTOM OF OPENING SHAU. NOT BE MORE THAN 44' ABOVE - FIREPLACE CODE COMPLIANCE PER UBC CHAPTER 314 AND ; LOCAL BLDG DEPARTMENTS A1130 REBAR AS PER WIC SEC. 310ali _ ,..! I HEARTH D/MISISIONS - HEARTH SHALL EXTEND MIN 16° FROM THE FRONT, AND 11 MIN BEYOND EACH SIDE OF THE FIREPLACE LARGER THE HEARTH EXTENSION SHALL BE 20" IN FRONT AND .-12" TO EACH SIDE OF OPENING. CONCRETE OR MASONRY MUST NOT BE SUPPORTED ON WOOD FRAMING. APPL AND INSTALL OF INSULATION AND VAPOR BARRIER SHALL COMPLY WITH 1994 STATE OF WASH ENERGY CODE. - GLAM1G Di COMPLIANCE WITS SEC 2406 UBC STD NO 242 ANIi . 1ASS, ,, LA : Iiii o; EXCEPTIONS ARE OUTLINED IN . RECEIVED CITY OF TUKVVILA PERMIT CENTER ,SLAZING AND LOCATAD91. SUIDECT TO HUMAN IMPACT SUCH AS - .GLASS ON DOORS. GAMING wmt 12a ON EITHER SIDE OF A DOOR OPENING, GLAZING CLOSER 'THAN 18" TO A FLOOR OF SHOWER DOOR AND THE TUB ENCLOSURE SHALL BE EITHER - TEMPERED GLASS, LAMINATED SAFETY GLASS OR SHATTER RESISTANT PLASTIC, OR WIRE REINFORCED GLASS FOR I SLIDING GLASS DOORS GLAZING TO BE LAMINATED OR - SHOWER ENCLOSURES SHALL BE APPROVED WIRE REINFORCED, TEMPERED OR LAMINATED SAFETY OR SHATTER RESISTANT MASTIC SEC 2406 UBC. GLAZING WITHIN 18" OF FLOOR AND GREATER THAN IN LEAST DIMENSION SHALL COMPLY WITH IMPACT LOADS, SEE PLANS, SEC 2406 AND UBC STD 24 A. ALL EXTERIOR WALL GLAZING SHALL BE DOUBLE GLAZED AND , COMPLY WITH 1994 STATE OF WASH ENERGY CODE. TREATED WOOD/WEATHER PER UBC SEC 2317 STD, STANDARDS ' detail s-1 general STRUCTural NOTES 4L CONSTRiC +ON 5 .4 5E N COWORIANCE r- L+E i4'=v'Rm B'.. , CODE NEC) 1e91 EDITION WIT WASA'tiGT i STATE .VENDMENTS. pE51G N LOAD5: ROOF LivE LOAD DEAD '.-CAP FLOOR LIVE DEAD LO WIND BASIC WIND 5PEED EXPOSURE E, : = 1.0 SEISMIC ZONE Ca = 036, ; x 1 .0, R=5.5 25 P5F (SNQ i;; 15 PF.F 40 PSG /RESIDENTIAL: 10 PSF 80 MPH 4NSPECTiONS: NO SPECIAL INSPECTIONS ARE REQUIRED. NOTIFY THE BUILDING DEPARTMENT FOR INSPECTIONS REQUIRED BY LOCAL ORDINANCE. ALL PREPARED SOIL BEARING SURFACES SHALL BE INSPECTED BY SOILS ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. !FOUNDATIONS: PLACE FOOTINGS ON NATIVE OR COMPACTED SOIL WTH 2,000 PSF BEARING CAPACITY (ASSUMED). $OTTOM OF EXTERIOR FOOTINGS SHALL SE MINIMUM i' -6" BELOW OUTSIDE FINISHED GRADE. BACKFILL - WALLS WIN A WELL DRAINING MATERIAL FREE OF ORGANIC OBJECTS OR DEBRIS. CONCITE: . THE SELECTION CIF MATERIALS FOR AND THE MIXING AND PLACING OF ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE UNIFORM"! BUILDING CODE, 1991 EDITION. !MATERIALS SHALL BE PROPORTIONED TO PRODUCE A DENS, WORKABLE MIX HAVING A MAXIMUM SLUMS C= 4 iNCI -+ES WHICH CAN BE PLACED UJITI4OUT SEGREGATION OR EXCESS FREE SURFACE WATER. USE MINIMUM -F'c = 2 PSI WIN 5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A MXIMUM OF 6 GALLONS OF WATER PER 94 LB SACK OF CEMENT. MAXIMUM SIZE OF AGGRREGATE i5 11/2" ALL CONCRETE SMALL BE POURRED 1 1 BETWEEN CONTRUCTION OR EXPANSION JOINTS UNLESS SHOIN OTHERWISE. • REINFORCING STEEL: ALL ALL REINFORCING STEEL SHALL BE GRADE 40 DEFORMED BARS iN ACCORDANCE WITH 4S111 SPECIFICATION A -615. LAP ALL SPLICES 32 BAR DIAMETERS, OR 1' -6" MINIMUM ULESS OTHERWISE 5I -IOWN. PROVIDE ELBOW EARS (32 DIA.) TO LAP HORIZONTAL STEEL AT CORNERS AND INTERSECTIONS IN FOOTINGS AND WALLS. R ZINFORCEMENT SHALL BE ACCU; T ELY PLACED AND ADEQUATELY SUPPORTED' EY APPROVE, CHAIRS, 5FACE.IRS, OR TIES AND SECURED N PLACE DURING GROUT OR CONCRETE PLACEMENT. MINIMUM CONCRETE COVER FOR REINFORCING STEEL: USE PROTECTION BLAB AND WALL BARS: INTERIOR FACES EXPOSED TO WEATHER OR EARTH FOOTING ''.•ARS 3" TIMBER: ALL LUMBER SHALL 5E 45 FOLLOWS UNLESS NOTED OTHERWISE: BEAMS POSTS 2x FRAMING DF"2 OR BETTER DF"2 OR BETTER HP2 CR BETTER 1 1, 2 1I /2" ( AND SMALLER) 2" ("6 AND LARGER) ALL 2x TIMBER SHALL BE KILN DRIED. ALL GRADES SHALL CONFORM TO "WI.JPA GRADING RULES FOR WESTERN LUMBER ", LATEST EDITION. ALL I,UOCD IN CONTACT WITH CONCRETE SMALL BE PRESSURE TREATED. MAINTAIN MINIMUM 6" CLEAR BETWEEN WOOD AND EXPOSED EARTH. ALL NAILS SHALL BE GALVANIZED BOX CR CO ION NAILS. ALL MINIMUM NAILING SHALL BE PER LICE TABLE 23- i1 -B -i UN.C. MACHINE BOLTS TO BE A -301. BOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH STANDARD CUT WASHERS. MISCELLANEOUS HANGERS TO BE 'SIMPSON' OR ICBO APPROVED EQUAL. ALL 4- ;ANGERS TO BE FASTENED TO WOOD WIN PROPER NAILS. ALL MOLES SHALL BE NAILED. CsLtD LA1"'s1 N,4TED i110OD ME GLUED LAr".INA ED WOOD BEAms (GLR3; TO BE N ACCO' A.NCE ,417I", ANSI STANVARD At901, AMERICAN NATIONAL 5T AND,1RD ST :TU SLUED M: TED T E . ..15 ..15 STRSS C COQ INAT i ^. FOQ 4`►; F:lL LA 24F- V4 '=o = 2 400 P5`) FOR 5rPLE SPANS AND 24F -V8 FOR C.1N7'LEVER AND :ONTN:,+CV6 SPANS. GL.E SHALL BE CA+Hs'N WITH MOLD 1NI4IBITOR UNLESS ONER:JiSE EC7 ED, SEALER 5,-,ALL SE APPL=ED TO ENDS cc .SILL ME!ISERS BOTTOM LAMINATION TO SE FREE OF UNWIND KNOTS LARGER 714/- 1/2 DIAMETER 4ITC STAMP AND CERTIFICATION r2EQU°, PREFABRICAT5D JOISTS: JOISTS SMALL SE A5 NOTED ON THE PLANS AisiD AS MANILFACTU BY TRUSS JOIST MACMILLAN CR APPROVED EQUIVALENT. JOISTS TO EE ERECTED IN ACCORDANCE 'WITI- T? E FLANS AND THE MANURACTURER'S DRAWINGS AND INTALLATION INSTRUCTIONS. CONSTRUCTION LOADS BEYOND THE DESIGN LOADS ARE NOT PERMITTED. PROVIDE E BRACING UNTIL SHEATHING MATERIAL HAS BEEN INSTALLED. PROVIDE SOLID BLOCKiNG AT CONCENTRATED LOADS FROM ABOVE AND 1E5 5TIFFENERS PER MANUFACTURER'S DI PARALLEL STRAND LUMBER (PSL): PARALLEL STRAND LUMBER (PSL) TO BE BY TRUSS JOIST MACMILLAN (PAR4L.LAM) OR APPROVED EQUIVALENT (Fb = 2,900 PSi, E = 2.0 x I06 PSI). MATERIAL SHALL BE DESIGNED .t MANUFACTURED TO THE STANDARDS SET FCRTH iN NER -292 OR GCMG REPORT NO. 11161 -R SEARiNG LENGTH SHALL NOT SE LESS THAN 1 1/2 ". DO NOT CUT OR NOTCH BEAMS WITHOUT PRIOR APPROVAL OR ENGINEER. HEEL CUTS SHALL NOT OVERHANG INSIDE FACE OF SUPPORTING MEMBER .EARING UjALLI FRAMING: - ALL DOOR AND WINDOW i- HEADERS NOT CALLED OUT OR OTHERWISE NOTED ON THE PLANS SHALL BE 4x10 DF2 WITH ONE CRIPPLE AND ONE STUD EACH END FOR OPENINGS 5' -0" OR LESS AND TWO CRIPPLES AND ONE STUD FOR OPENINGS MORE 11-44N 5' -0" WIDE. ALL COLUMNS NOT CALLED OUT ON THE PLANS SHALL BE TWO (2) STUDS. SPiKE LAMINATED COLUMNS TOGETHER WiTH 16d 6 16" O.C. STAGERED. STAGGER SPLICES AT TOP PLATES MINIMUM 48" AND NAILS WITH I6d g 8" O.C. SHEAR WALLS: ALL SHEAR WALL SHEATHING NAILING AND ANCHORS SHALL SE AS DETAILED ON THE DRAWINGS AND NOTED IN THE SHEAR WALL SCHEDULE. USE AP.A RATED SHEATHING (24/0) WITN A MINIMUM PANEL EDGE NAILING OF ad ® 6" O.C. UNLESS NOTED OTHERWISE. ALL SHEAR WALL NAILING SHALL. BE COMMON WIRE OR GALVANIZED BOX NAILS. BLOCK ALL UNSUPPORTED PANEL EDGES. ALL NAVE STRAP CONNECTORS TO THE TOP PLATE AT EACH END WHEN THE DEADER INTERRUPTS THE TOP PLATE. USE 'SIMPSON' MSTA24 CONNECTOR UN.O. FLOOR AND ROCS FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS TI-IAT EXTEND OVER MORE THAN HALF NE LENGTH AND ALL AROUND ALL OPENINGS !N FLOORS AND ROOFS UN.O. APPLY 3 /4 i RATED SHEATHING (40/20) GLUED AND NAILD TO FLOOR FRAMING- MEMSERS WITH ad COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT ALL SUPPORTED EDGES AND 8d COMMON CR GALVANIZED BOX NAILS AT 12" O. C. AT INTERIOR SUPPORTS. APPLY 1 /2" RATED SHEAT;ING (24/0) ON ROOF NAILED TO STIFFENERS CR R4FTERS WITH ad COMMON OR GALVANIZED BOX NAILS AT SUPPORTED EDGES AND ad COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. LAY SHEATHING PERPENDICULAR TO FRAMING AND STAGGER PANEL EDGES. ROOF TRUSSES: TRUSSED TO BE DESIGNED AND SUPPLIED IN ACCORDANCE WITH UBC SECTION 2321. DESIGN TO BE EY A PROFESSIONAL ENGINEER LICENSED IN NE STATE OF WASHINGTON. MEMBERS SHALL BE SIZED TO ACCOMDATE A 25 PSF SNOW LOAD AND ALL DEAD LOADS. EACH TRUUE'S SHALL BE PLANT FABRICATED AND SHALL BEAR NE QUALITY CONTROL STAMP, MANUFACTURER'S NAME, DESIGN LOAD, AND MAXIMUM SPACING. ALL MECHANICAL CONNECTORS SHALL BE 1050 APPROVED AND LOADS 51-4ALL BE IN ACCORDANCE WITH NE RECOMMENDED ALLOWABLE LOADS. MANUFACTURER SHALL PROVIDE ALL FRAMING -TO -TRUSS AND TRUSS -TO -TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. FABRICATOR. SHALL SUBMIT Si-40P DRAWINGS TO THE BUILDING DEPARTMENT FOR APPROVAL AND VERIFY ALL TRUSS LENGTHS PRIOR TO FABRICATION. GENERAL CONSTRUCTION NOTES: ALL CONSTRUCTION SHALL CONFORM TO NE UNIFORM BUILDING CODE (UBC), 199'1 EDITION. NE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND METHODS, TECHNIQUES, AND SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE SPECIFIED WORK. NE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITONS AT NE JOB SiTE INCLUDING BUILDING AND SITE CONDTIONS BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR SAME. NE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING 4,5 REQUIRED UNTiL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. NE CNTRACTOR SHALL COORDINATE WIN NE BUILDING DEPARTMENT FOR ALL BUILDING DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. NE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR SIMILAR CONDITIONS NOT 51- 401.1.I. VARIATIONS AND MODIFICATIONS TO WORK SHOWN ON NE DRAWINGS SHALL NOT BE CARRIED OUT WITHOUT NE WRITTEN PERMISSION FRO THE ARCHITECT OR ENGINEER. APPROVED APR 2 2 2CO2 ii■S NU etr LDING DI`t' %t^N RECEIVED CITY OF TUKWILA FEB 2 6 2002 PERMIT CENTER Ilan Ate TWO CRIPPLES AND STUD O . 5 Ir WIDE. ALL COLUMNS Nur Cum OUT ON TNE SHALL GE 2 STUDS, S *mamma) COLUMNS . VaTH 16d Sr *6" 0 modem TOP PLATE MIN 4' AND MI= PER UDC TABLE 23-11-11-1. DOUBLE JOISTS ALL MINT EXTEND OVER MORE THAN ONE HALF ins mem MD WROUND ALL OPT Ili FLOOR AND ROOFS, APPLY 3/4$ TED PLYWOOD (40/20) NAILED TO FLOOR MOWN MENDERS larnt Id GALVANIZED BOX MAILS AT 6" O.C. AT ALL SUPPORTED AND Id GALVANIZED BOX NAILS AT 12' O.C. AT 1IUPPORTs UNLESS NOTED OTIWRWISE ON PLANS. APPLY 1/2" ;RATED SHEATHING (24/0) ON ROOF NAILED TO STIFFENERS OR WItTM a •ALVAN1ZED NAILS AT 12" O.C. AT GAIL! ENDS ` > O.C. AT ALL OTHER SUPPORTED EDGES, AND 8d GALVANIZED • ► NAILS AT 12" O.C. AT INTERIOR SUPPORTS UNLESS NOTED tionstwist ON PLANS. . 4= I.00CD1G OF INTERIOR EDGES NOT REQUIRED UNLESS NOTED . ON THE PLANS. Y SHFATMIIG PERPENDKULAR TO FRAMMIG AND STAGGER ._- PANEL EDGES. . • itINDRAILS TO HAVE END RETURNED AND TO BE MIN 34" AND 311" ABOVE TREAD NO IG. v ''44ANIDGRIP PORTION ON HANDRAIL MALL NOV DE USS THAN i 3' NOR MORE THAN 2' IN CROSS SECTIONAL DIMENSION OR SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. ' 'HANDRAIL PROJECTOR FROM THE WALL SHALL HAVE NOT LESS 1 1./3" IN SETWEEM THE WALL AND THE HANDRAIL SEC ALL FIRE SLOOONG BETWEEN STRINGER AT TOP AND BOTTOM IN WALL ALONG STRINGERS PU SEC 2516(f) UDC ' WAWA SPACE UNDER STAIRS TO HAVE sir TYPE "X" 'WALL. BOARD AT WALLS AND SOFFITS PER SEC 3306(m) 4OUNDATION AN) FLOOR SLM =MUM SMALL BE _ To X300 Ps . MAX %wow TO anew RATX) 5 1/2 SACK 4Et CUBIC YARD OF canconi Me S 314 GAL WATER PER 04 LB 'SACK OF CEMENT. -- ..r . - _ -r - r . '''..' ' r IPS1 ASSUMEDCOMPRESSIVE STRENGTH AT'S DAY& t.: covE.RAGE OF sun 3" DOT ln, r SlolS. - • 4 - . " A USE r NOMINAL t IMAMS HEADERS AND LAMS: 4 OF*2 . r NOMINAL DF01 'ISTUDS 2X4 OR 2X6 FIR 02.10) FifIGLU LAM BEAMS 24 F-V4 (Fb *2440 PSI) FOR PPM CANITU EVER AND COW SlA1Et 24148 _ . �„ I'VE PLANS FOR PLYWOOD. STRUCTURAL FRAMING MARK MINIMUM SHEATHING (1) SHEATHING NAILING (1) SILL PLATE NAILING ANCHOR BOLTS (3) REMARKS USE 3x STUDS • ABUTTING PANEL EDGES 4 STAGGER EDGE NAILING. I EXMOOR S€A1MING PER P-AN OR SCHEDULE ed•4' 2:x BLOCKING al 16d NAL • 8' OC I. RATED SHEATHNG TRiS6 OR RAFTER PER p-.AN 82ID 2 BLOQCNG FRAMING AT INTERIOR SWEAR WALL 2x STUD PER PLAN T gt• RATED y€AT141I3 ed • 6' OC. 2x vENTED Bi-JCKIrCa. NAIL TO TRUSS I EACH END. SHEATHING AND NAILING PER PLAN OR SCHEDULE. mradrimnrribeihrn GIRDER TRUSS PER PLAN 2x SAID PF.-R PLAN. USE DE=L STUD • ENDS OF SHEAR W.ALL5 4 14OLDOUN5. 5HEA1THiNG I NAILING PER PLAN. 'SIMPSON' 14OLDC(Lt4 PER PLAN. 24" CONTINUOUS FTC. REINFORCEMENT L STEM WALL FRAMM ANCHOR L. "7% FOUNDATION AT CRAWL SPACE 2x STUD TRUSS PER PLAN 'SMPSON' 14$20 MIST STRAP. DBL 2x TOP PLATE SOLE PLATE NAILING. USE 16d I I6" OC. MIN. 3 / 4 " SHEATHING 2x PT SILL WITH ANCHOR BOLT PER PLAN OR SCHEDULE. USE kb". • 60" OC. MIN. '4 BAR CONTINUOUS. (TYP '4 BAR CONTINUOUS (TYP.) 1 MAX DBL 2x TOP PLATE LAP SPLICE 4 MIN. 4 NAIL W I6d • 6' OC. STAGGED It' RATS SHEATHING ad • 6' OC. SWATHING 4 NAIL NG PER PLAN OR bNEAR WALL 5C €DULE '5MPSON' HOLDOLLN STRAP PER PLAN 5HE4TNING 4 NAILING PER PLAN. SPLICE TO OCCUR ON COPfrMON 'MEMBER OR BLOCKING 2x STUDS PER PLAN. (BEAM AT WI) NOTE: DO NOT BACKFILL UNTIL FLOOR SHEATHING, PONY WALL SHEATHING, AND SLAB ON GRADE ARE INSTALLED PER PLAN. 2x PT SILL w/ %" +ANCHOR BOLT • 32 "OC. WO. 04 BAR • 10" O.C. HORIZONTAL °5 BAR • 10" OC. VERTICAL 4 "0 FTG DRAIN 820 ROOF FRAMING • GABLE END d r I'-[," L..._ 14 l FOUNDATION AT BASEMENT 7 -6AOLE END TIRL 66 'SIMPS N' A35 • 32' OC. / DL 2x TOP PLATE. LAP SPLICE 4'-0' r• Mft 4 NAL .116d 8' OC. STAGGERED. SOLE PLATE NAILING. USE I6d I 16' OC. MIN. SOLID RIM JOIST 3 4' SUBFL.00R 2x DBL TOP PLATE. LAP SPLICE 6' -0" MM. 4 NAIL W 16d • 6' O.C. STAGGERED. TYPICAL FLOOR FRAMING CONNECTION 'SIMPSON' A35 JOIST PER PLAN 3/4" SHEATHING (40/20) JOIST PER PLAN -I (I 2) 4 4 BAR •TOP 4" SLAB ON GRADE FOUNDATION PENETRATION t s RATED SHEATHING (2410) SHEAR WALL SCHEDULE I SWATH * NAILING PER PLAN OR SCHEDULE 51 EATH NG PER PLAN OR SCHEDULE '4 BAR CONTINUOUS (TYP TOP 4 BOTTOM) 'SIMP'SON' 14O DOLLN PER PLAN FOUNDATION AT SLAB ON GRADE tzf 1 \ 4 1 ock 2 11-*111 Rio to \ 2x PT SILL ua/ i "+ ANCHOR BOLT. DBL 2x TOP PLATE LAP SPLICE 4'-0' Mk 4 NAIL so/ i6d # 8' OG. STAGGERED 2x STIE PER PLAN. USE DBL • HOLDO(IN. SLAB CS GRADE PER PLAN OvER 6 MIL vAPOR BARRIER ON COMPACT BASE. '4 BAR CCNT. (TYP.) NOTES I) ALL WALLS DESIGNATED" ®" ARE SHEAR WALLS. EXTERIOR WALLS SHALL BE SHEATHED WITH RATED SHEATHING (24/0, OSB OR CDX) AND NAILED AT ALL PANEL EDGES (BLOCKED) PER SCHEDULE). NAILING AT INTERMEDIATE FRAMING TO BE AT 12" OC. NAILING NOT CALLED OUT SHALL BE PER UCB TABLE 23- II -B -1. RECEIVED CITY OF TUKWILA FEB 2 6 2002 PERMIT CENTER 2) HOLDOWNS AND OTHER FRAMING HARDWARE BY SIMP CN STRONG TIE OR EQUIVALENT TO BE USED PER PLAN. ENDS OF SHEAR WALLS SHALL USE DOUBLE STUDS MINAMlM. 3) USE MINIMUM OF TIUO (2) BOLTS PER SILL PIECE WITH ONE BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 5" FROM EACH END OF EACH PIECE. EMBED BOLTS MINI OF 1" INTO CONCRETE. WASHERS TOE MINIMUM 2' x 2" x 3/16 ". EXPIRES: 3/12/0 I These plans have been reviewed by the Public _Works Department for conformance with current City standards. Acceptance is subject.to errors and omissions which do not authorize violations of adopted standards or ordinances. The responsibility for the adequacy of the design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final . acceptance is subject to field inspection by 'rZhe Public Works utilities inspector. Date: By: 'REVIEWED AND APPROVED FOR OEOTECH$I CAL DRAINAGE - .CONSIDERATIONS. "' NOV 2 1 2002 • PERMIT CENTER DATE 1 REVISIONS NO DATE APPROVED BY TYPE OF REVISION LONG CLASSIC HOMES ENUM1iCLAW,WA aav::wr<m DRAWN S REVISED LOT 15 FOSTER HEIGHTS KING COUNTY, WA DRAWIN N M'ER SITE, UTILITY , DRAINAGE PLAN F 5 APPR BY LPA E GAL CEL A: DESC RIPTION OF RECORD THE WEST HALF OF LOTS 10 AND 11. B100( 4. ADAMS HOME ACRE TRACTS. ACCORDING TO THE PLAT THEREOF. RECORDED IN VOLUME 11 OF PLATS, PAGE(S) 31, IN KING COUNTY, WASHINGTON: TOGETHER WITH AN EASEMENT FOR INGRESS AND EGRESS OVER THE SOUTH 15 FEET OF THE EAST HALF OF LOT 11. SAID BLOCK 4 AS SET FORTH IN INSTRUMENT RECORDED UNDER RECORDING NUMBER 3573883 PARCEL B: LOT 12. BLOCK 4. ADAMS HOME TRACTS. ACCORDING TO NE PLAT THEREOF. RECORDED IN VOLUME 31. IN KING COUNTY, WASHINGTON. PARCEL C: VEST HALF OF LOT 13. BLOCK 4, ADAMS HOME TRACTS, ACCORDING TO THE PLAT THEREOF. RECORDED IN VOLUME It OF PLATS. PAGE(S) 31, IN KING COUNTY, WASHINGTON. PARCEL 0: LOT 14. BLOCK 4. ADAMS HOME ACRE TRACTS. ACCORDING TO THE PLAT THEREOF. RECORDED IN VOLUME 11 OF PLATS. PAGE(S) 31, IN KING COUNTY, WASHINGTON. METES AND BOUNDS LEGAL DESCRIPTION A PORTION OF BLOCK 4 OF ADAMS HOME TRACTS ACCORDING TO THE PLAT THEREOF AS RECORDED IN VOLUME 11 OF PLATS. PAGE 31 IN KING COUNTY, WASHINGTON, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHEAST CORNER OF SAID BLOCK 4; THENCE NORTH 0130'37 EAST ALONG THE EAST UNE OF SAID BLOCK 103.09 FEET TO THE TRUE POINT OF BEGINNING; THENCE CONTINUING NORTH 01 30 EAST ALONG SAID EAST UNE 103.09 FEET; THENCE NORTH 87'53'42" WEST 189.29 FEET; THENCE NORTH 0127'47' EAST 206.31 FEET; THENCE NORTH 87'51'26' WEST 189.46 FEET; THENCE SOUTH 01'24'57' WEST 10122 FEET; THENCE NORTH 87'5234" WEST 126.11 FEET; THENCE SOUTH 01'23'03' WEST 309.78 FEET; THENCE SOUTH 6T55'58" EAST 315.06 FEET; THENCE NORTH 012747' EAST 103.16 FEET; THENCE SOUTH 87'54'50" EAST 189.20 FEET TO THE POINT OF BEGINNING. EXCEPT THEREFROM THE ROAD RIGHT OF WAYS AS SHOWN TO BE DEDICATED TO THE PUBLIC ON THE MAP PAGE (PAGE 3 OF 3) OF THIS PLAT. DEDICATION KNOW ALL PEOPLE BY THESE PRESENTS, THAT WE, THE UNDERSIGNED, OWNER(S) IN FEE SIMPLE OF THE LAND HERON DESCRIBED DO HEREBY MAKE A SUBDIVISION THEREOF PURSUANT TO ,tRCW 58.17.16. THE UNDERSIGNED FURTHER DECLARE THIS PLAT TO BE THE GRAPHIC REPRESENTATION OF THE SAID SUBDIVISION AND THE SAME IS MADE WITH THE FREE CONSENT AND IN ACCORDANCE MTH THE DESIRE OF THE OWNER(S). KNOW ALL PEOPLE BY THESE PRESENTS THAT WE THE UNDERSIGNED, OWNERS IN FEE SIMPLE AND UEN HOLDERS OF THE LAND HEREBY PLATTED, HEREBY DECLARE. DEDICATE AND CONVEY TO THE CITY OF TUKWILA FOR THE USE OF NE PUBUC FOREVER ALL STREETS, WATER, STORM DRAINAGE AND SANITARY SEWER SYSTEMS LOCATED ON EASEMENTS AND RIGHTS- OF-WAY SHOWN THEREON AND THE USE THEREOF FOR ALL PUBLIC PURPOSES NOT INCONSSTENT WITH THE USE THEREOF FOR PUBLIC ROADWAY AND UTILITY PURPOSES; ALSO THE RIGHT TO MAKE ALL NECESSARI SLOPES FOR CUTS AND FILLS UPON THE LOTS AND BLOCKS SHOWN ON THIS PLAT IN THE ORIGINAL REASONABLE GRADING OF SAID STREETS AND ALLEYS SHOWN THEREON. THIS DEDICATION OF THE PROPOSED PUBUC ROADWAYS AND UT1UTIES IS SUBJECT TO THEIR COMPLETION BY THE DEVELOPER AND THE ACCEPTANCE AND APPROVAL BY THE PUBLIC WORKS DIRECTOR THAT THEY HAVE BEEN COMPLETED TO CITY STANDARDS. WE AND ALL OF OUR SUCCESSORS WAIVE ALL CLAIMS FOR DAMAGES AGAINST ANY GOVERNMENTAL AUTHORITY ARISING FROM THE CONSTRUCTION AND MAINTENANCE OF PUBLIC FACILITIES AND PUBLIC PROPERTY .YITHIN THE SUBDIVISION. (17.04.060 8.2.) IN WMTN : ' REOF WE HAVE SET OUR HANDS AND SEALS. MICHAEL K AN . PRESIDEN , TRIDOR, INC. ACKNOWLEDGMENTS STATE OF WASHINGTON ) ) SS ) COUNTY OF KING STATE OF WASHINGTON ) ) SS COUNTY OF KING 5URVEYOR CERTIFICATE PRELIMINARY PLAT NO. L98 -0019 FINAL PLAT NO. L2000 -026 ON THE 3 RD LAY OF :q 20 01__ BEFORE ME, THE UNDERSIGNED NOTARY PUBUC IN AND FOR THE STATE OF WASHINGTON, PERSONALLY APPEARED MICHAEL S.K. CHAN TO ME KNOWN TO BE PRESIDENT OF TRIDOR, INC., A WASHINGTON CORPORATION. THAT EXECUTED THE FOREGOING INSTRUMENT. AND ACKNOWLEDGED SAID INSTRUMENT TO BE THE FREE AND VOLUNTARY ACT AND DEED OF SAID CORPORATION FOR THE USES AND PURPOSES THEREIN MENTIONED AND ON OATH STATED THAT 4-I WAS AUTHORIZED TO EXECUTE SAID INSTRUMENT. IN WITNESS WHEREOF, I HAVE HEREUNTO SET MY HAND .\ND AFFIYED `.IV OFFICIAL SEAL THE DAY AND YEAR FIRST ABOVE WRITTEN. PRINT NAME OF NOT Y QHruS JIAe� In AN SIGNATURE OF / - i / NOTARY PUBLIC t DATED 3_ 2 0o I MY APPOINTMENT EXPIRES SA-4 t o9 ON THE R P _DAY OF .-7 L 200 ( BEFORE ME, THE UNDERSIGNED NOTARY PUBLIC IN AND FO THE STATE OF WASHINGTON. PERSONALLY APPEARED J4 1K.- L;�, 2n (� TO ME KNOWN TO BE VI. D: , =s,ti. , Zy,.L3" OF CITYBANK, THAT EXECUTED THE FOREGOING INSTRUMENT, AND ACKNOWLEDGED SAID INSTRUMENT TO BE THE FREE AND VOLUNTARY ACT AND DEED OF SAID CORPORATION FOR THE USES AND PURPOSES THEREIN MENTIONED AND ON OATH STATED THAT 4'E WAS AUTHORIZED TO EXECUTE SAID INSTRUMENT. IN WITNESS WHEREOF, I HAVE HEREUNTO SET MY HAND AND AFFIXED MY OFFICIAL SEAL THE DAY AND YEAR FIRST ABOVE WRITTEN. STATE OF WASHINGTON • COUNTY OF 4/7 REGISTERED AS A LAND SURVEYOR BY THE STATE WASHINGTON, CERTIFY THAT THIS PLAT IS BASED ON AN ACTUAL SURVEY OF E LAND DESCRIBED HEREIN, CONDUCTED BY ME OR UNDER MY SUPERVISION: T1-IAT THE DISTANCES, COURSES AND ANGLES ARE SHC'1N`I THE.RCUN GUr'.r..i iLr; A NJ THAT % OTHER T; IAN T1 MONUMENTS APPROVED FOR SETTING AT A LATER DATE, HAVE BEEN SET AND LOT CORNERS STAKED ON THE GROUND AS DEPICTED ON THE PLAT. FOSTER HEIGHTS A PORTION OF THE NE1 /4, SEC.22, T.23N., R.4E. KING COUNTY, WASHINGTON CITY OF TUKWILA STATE OF WASHINGTON COUNTY OF K, ,4 q PRINT NAME OF NO;FARY eh2Fs Sl e A.„/ SIGNATURE OF / �)/, // _ _ /_ , NOTARY PUBUC DATED ZuEtt 3, Zoe I MY APPOINTMENT EXPIRES StAft 09 ,: 2 - 0 03 11 OF PLATS, PAGE(S) EXPIRES 11/30/02 I1 ar,' OF TUKWILA APPROVALS FIJBUC WORKS DIRECTOR'S CERTIFICATE 1 HEREBY APPROVE THE SURVEY DATA. NE LAYOUT OF THE STREETS, ALLEYS AND OTHER RIGHTS -OF -WAY, DESIGN OF SEWAGE AND WATER SYSTEMS, DRAINAGE SYSTEMS AND OTHER STRUCTURES. I CERTIFY THAT THE SUBOIVIDEIj HAS COMPUED WITH ONE OF THE FOLLOWING: A. ALL IMPROVEMENTS HAVE BEEN INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THIS TITLE AND WITH THE PRELIMINARY PLAT APPROVAL AND THAT ORIGINAL AND REPRODUCIBLE MYLAR OR ELECTRONIC RECORDS IN A FORMAT APPROVED BY PUBLIC WORKS AND MEETING CURRENT PUBLIC WORKS DRAWING STANDARDS FOR ROAD. UTILITY AND DRAINAGE CONSTRUCTION PLANS CERTIFIED BY THE DESIGNING ENGINEER AS BEING - AS CONSTRUCTED' HAVE BEEN SUBMITTED FOR CITY RECORDS. B. AN, AGREEMENT AND BOND OR OTHER FINANCIAL SECURITY HAVE BEEN EXECUTED IN ACCORDANCE WITH SECTION 17.24.030 OF THIS TITLE SUFFICIENT TO ASSURE COMPLETION OF REQUIRED IMPROVEMENTS AND CONSTRUCTION PLANS. EXAMINE% AND APPROVED BY THE CITY OF TUKWILA DEPARTMENT OF PUBLIC WORKS TtYS r ICE'sss-hC1 s l .f t IT DIRECTOR CITY TREASURE'S CERTIFICATE THERE ARE NO DELINQUENT SPECIAL ASSESSMENTS. AND ALL SPECIAL ASSESSMENTS ON ANY OF THE PROPERTY THAT IS DEDICATED AS STREETS, ALLEYS OR FOR OTHER PUBUC USE ARE PAID IN FULL. .. ?leolot FINANCE DIRECTOR DATE JMAYOR AND CITY CLERK'S APPROVAL EXAMINED AND APP THIS Cyl DAY TUKWILA •'AYOR kING COUNTY APPROVALS KING COUNTY TREASURER'S CERTIFICATE I CERTIFY THAT ALL PROPERTY TAXES ARE PAID AND THAT A DEPOSIT HAS BEEN MADE IN SUFFICIENT „ ICUNT TO PAY THE TAXES FOR THE FOLLOWING YEAR; THAT THERE ARE NO DELINQUENT SPECIAL ASSESSMENTS CERTIFIED TO THIS OFFICE FOR COLLECTION; AND THAT ALL SPECIAL ASSESSMENTS ON ANY OF THE PROPERTY HEREIN DEDICATED AS STREETS. ALLEYS, OR FOR OTHER PUBLIC USE ARE PAID IN FULL THIS 1±1 DAY OFjU VED BY THE CITY OF TUKWILA 2004 . • TY KING COUNTY ' F , NG COUNTY (TREASURER EXAMINED AND APPROVED THIS _ f �AYOF 2 ' 2044f A.D. KING COUNTY ASSESSOR DEPUTY KING COUNTY ASSESSOR RECORDING CERTIFICATE FILED FOR RECORD AT THE REOUEST OF THE CITY OF TUKMLA THIS 1 0AL A.D., AT �� MINUT SS PAT RECORDED IN VOLUME _ 2oo_OF PLATS, PAGES B / kING COUNTY, WASHINGTON. DIVISION ON OF RDS AND ELECTIONS DEPUTY DIRECTOR, KING COUNTY DEPARTMENT OF RECORDS AND ELECTIONS DIRECTOR, KING DEPARTMENT OF RRECORDING NO.�Qd � d� �d�t7QOO �v "NOTE" rmassfamostarommemerrestffloseamemencraisastrx WATER AND SANITARY SEWER SERVICE PROVIDED BY DISTRICTS. PREPARED BY DRAWN BYI [Nees 6 hoimiztii1.4 Inc. ENGINEERS & SURVEYORS 100 FRONT STREET SOUTH ISSAQUAH, WASHINGTON 98027 JOB NO. 1736 -001 MM CHECKED BYI WSH DATEI RECORDS OF COUNTY (Fj15SESSOR RECORDS AND ELECTIONS RECEIVE JUL ► 9 2001 TUKWILA PUBLIC WORKS (425) 392 - 0250 1736 -1 FP.DWG SHEETs UTILITY EASEMENTS N4 EASEMENT iS HEREBY RESERVED FOR AND GRANTED TO SEATTLE an' L GIT, US WEST TELEPHONE COMPANY, AT &T CABLE TV COMPANY AND OTHER UTIUTiES AND THEIR RESPECTIVE SUCCESSORS AND ASSIGNS. UNDER AND UPON THE EXTERIOR 10 FEET OF ALL LOTS AND TRACTS, PARALLEL WITH AND ADJOINING EXISTING OR PROPOSED ACCESS RIGHTS OF WAY AND TRACTS (BOTH PRIVATE AND PUBUC. AS WELL AS AN EASEMENT WITHIN ALL PRIVATE ROADS, TRACTS, AND DRIVES, IN WHICH TO WSTALL, LAY, CONSTRUCT, RENEW. OPERATE AND MAINTAIN UNDERGROUND DISTRIBUTION SYSTEMS WITH NECESSARY FACILITIES AND OTHER EQUIPMENT FOR THE PURPOSE OF SERVING THIS SUBDIVISION. AND OTHER PROPERTY. WITH uTiUTY SERVICES. TOGETHER 1MTH THE RIGHT TO ENTER UPON THE LOTS AT ALL TIMES FOR THE PURPOSES HEREIN STATED_ NO LINES OR WIRES FOR THE TRANSMISSION OF ELECTRIC CURRENT. OR FOR TELEPHONE USE. CABLE TELEVISION, FIRE OR POLICE SIGNALS. OR FOR OTHER PURPOSES. SHALL BE PLACED UPON ANY LOT UNLESS THE SAME SHALL BE UNDERGROUND OR IN CONDUIT ATTACHED TO A BUILDING. RESTRICTIONS 1. NO LOT OR PORTION OF A LOT IN THIS PLAT SHALL BE DIVIDED ANO SOLD OR RESOLD OR OWNERSHIP CHANGED OR TRANSFERRED WHEREBY THE OWNERSHIP OF ANY PORTION OF THIS PLAT SHALL BE LESS THAN THE AREA REQUIRED FOR THE USE DISTRICT IN WHICH LOCATED. NOTES: 1. SET I/2" REBAR AND CAP (LS 01332) AT ALL REAR CORNERS. SET TACK IN LEAD IN CURB AT THE SIDE LOT UNES PRODUCED TO AN INTERSECTION WI TH THE CURB UNE. 2. TRACT "A" iS A JOINT ACCESS AND UTILITY TRACT. 3. THE LOT OWNERS OF LOTS 9. 10 AND 11 HAVE AN UNDIVIDED OWNERSHIP IN TRACT `A" AND SHALL BE RESPONSIBLE FOR THE MAINTENANCE THEREOF. 4. THE RVE (5) FOOT PRIVATE DRAINAGE EASEMENT WITHIN LOTS 6 AND 7 IS FOR THE BENEFIT OF LOT 5 AND 6. THE OWNERS OF SAID LOTS SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACILITiES THEY HAVE BENEFIT OF USE. AND SHALL EQUALLY SHARE iN THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACILITIES ' ISED IN COMMON. 5. THE FIVE (:;) FOOT DRAINAGE EASEMENT WITHIN LOTS 2, 13 AND 14 IS FOR THE BENEFIT CF LOTS 13, 14 AND 15. THE OWNER OF SAID LOT SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FAaLITiES THEY HAVE RENEflT OF USE. A'1n SMALL.. EQUALLY SHARE IN THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACILITIES USED IN COMMON 6. THE FIVE W.,j FOOT DRAINAGE EASEMENT WITHIN LOT . IS FOR THE BENEFIT OF LOT 10. THE OWNER OF SAID LOT SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACIUTIES THEY HAVE BENEFIT OF USE, AND SHALL EQUALLY SHARE iN THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACILITIES USED IN COMMON. 7. THE FIVE (5) FOOT DRAINAGE EASEMENT WITHIN LOTS 1, 2 AND 3 IS FOR THE BENEFIT OF LOTS 1, 2, 3 AND 4. THE OWNERS OF SAID LOTS SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACILITIES THEY HAVE BENEFIT OF USE. AND SHALL EQUALLY SHARE IN THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACIUTIES USED IN COMMON. 8. THE FIVE (5) FOOT DRAINAGE EASEMENT WITHIN LOTS 14 AND 15 IS FOR THE BENEFIT OF LOT 16. THE OWNERS OF SAID LOTS SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACIUTIES THAT THEY HAVE BENEFIT OF USE, AND SHALL EQUALLY SHARE THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACIUTIES USED IN COMMON. 9. THE TEN (10) FOOT DRAINAGE EASEMENT WITHIN LOT 9 IS FOR THE BENEFIT OF LOTS 1 -4. THE OWNERS OF SAID LOTS SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACIUTIES THEY HAVE BENEFIT OF USE, AND SHALL EQUALLY SHARE iN THE MAINTENANCE OF THAT PORTION OF THE DRAINAGE FACIUTIES USED IN COMMON. 10. ALL BUILDING DOWNSPOUTS, FOOTING DRAINS, AND DRAINS FROM ALL IMPERVIOUS SURFACES SUCH AS PATIOS AND DRIVEWAYS SHALL BE CONNECTED TO THE PERMANENT STORM DRAIN OUTLET AS SHOWN ON THE APPROVED CONSTRUCTION DRAWINGS ON FiLE WITH THE CITY OF TUKMLA PUBUC WORKS DEPARTMENT. THIS PLAN SHALL BE SUBMITTED WiTH THE APPUCATION FOR ANY BUILDING PERMIT. ALL CONNECTIONS OF THE DRAINS MUST BE CONSTRUCTED AND APPROVED PRIOR TO THE FINAL BUILDING INSPECTION APPROVAL. FOR THOSE LOTS THAT ARE DESIGNATED FOR INDIVIDUAL LOT INFILTRATION SYSTEMS. THE SYSTEMS SHALL BE CONSTRUCTED AT THE TIME OF THE BUILDING PERMIT AND AND SHALL COMPLY WITH PLANS ON FILE. 11. THE ROAD AND STORM DRAINAGE SYSTEMS SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLAN AND PROFILE ON ALE WITH THE CITY OF TUKWILA DEPARTMENT OF PUBUC WORKS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE PROPER AGENCY. 12. THE RESIDENCE ON LOT 15 SHALL BE PROVIDED WITH A SPRINKLER SYSTEM. 13. THE OWNERS OF LOTS 10 AND 11 OWN AND ARE RESPONSIBLE FOR THE MAINTENANCE OF THE TREES PLANTED ON THOSE LOTS AS REPLACEMENT TREES FOR TREES REMOVED IN STEEP SLOPE SENSITIVE AREAS. LOTS 10 AND 11 ALSO OWN AND ARE RESPONSIBLE FOR THE MAINTENANCE OF THE TREES PLANTED TO SCREEN THE STORM WATER DETENTION VAULT LOCATED ON THESE LOTS. THESE TREES ARE IDENTIFIED AS THE "TREE REPLACEMENT AND VAULT SCREENING EASEMENT" AREA ON THE PLAT MAP. THESE TREES ARE SUBJECT TO THE PROVISIONS OF TMC 18.54, TREE REGULATIONS, AND SHALL NOT BE REMOVED WITHOUT PRIOR APPROVAL FROM THE CITY OF TUKWILA DEPARTMENT OF COMMUNITY DEVELOPMENT. NOTE THE DEVELOPER SHALL COMPLY WITH GEOTECHNICAL REPORT PREPARED BY GEOSPECTRUM CONSULTANTS. INC. DATED FEBRUARY 10, 1998 AND SUBSEQUENT GEOTECHNICAL REPORTS. APPLICANT IS TO INCLUDE. AS PART OF THEIR SINGLE FAMILY PERMIT APPLICATION, A LETTER FROM THEIR GEOTECHNICAL ENGINEER THAT CERTIFIES ON A LOT BY LOT BASIS THAT THE HOME FOOTING AND FOUNDATION DESIGN INCLUDING FOOTING/FOUNDATION DRAINAGE SYSTEM ADDRESSES AND FULFILLS THEIR GEOTECHNICAL RECOMMENDATIONS. DURING HOME CONSTRUCTION, THE GEOTECHNICAL ENGINEER IS TO OBSERVE THE IMPLEMENTATION OF THE HOUSE DEVELOPMENT PLANS. FIELD REPORTS ARE TO BE SUBMITTED TO THE CITY AND TO INCLUDE: A) TEMPORARY EROSION CONTROL AND TEMPORARY EXCAVATIONS, B) IMPLEMENTATIONS OF FOOTINGS. FOUNDATIONS. RETAINING WALLS. DRIVEWAY PLACEMENT ANO ASSOCIATED DRAINAGE SYSTEM AND PLACEMENT OF BACKFILL THE GEOTECHNICAL ENGINEER IS TO PROVIDE CERTIFICATION ON A LOT BY LOT BASIS THAT THE WORK HAS BEEN ACCOMPUSHED IN ACCORDANCE WITH THE GEOTECHNICAL RECOMMENDATIONS. EACH OWNER IN ITS PURCHASE OF A LOT, HEREBY ACKNOWLEDGES THAT THE PLAT OF FOSTER HEIGHTS, AS APPROVED BY THE CITY OF TUKWILA, CONTAINS AREAS CONSISTING OF STEEP SLOPES. EACH OWNER HEREBY RELEASES THE CITY OF TUKWILA AND ITS OFFICERS. AGENTS AND EMPLOYEES FROM ALL CLAIMS. ' ` . ' ACTIONS, CAUSES OF ACTION. COSTS, ATTORNEYS AND EXPERTS FEES OR PROPERTY DAMAGE ARISING FROM THE PRESENCE OF 3rEP SLOPES 'rri11:N THE PLAT, PROVIDED, THAT !HIS RELEASE SHALL UT APPLY TO CLAIMS, ACTIONS, CAUSES OF ACTION, COSTS, A TTORNEY'S AND EXPERTS FEES AND PROPERTY DAMAGE RESULTING, FROM THE SOLE OR CONTRIBUTORY NEGLIGENCE OF THE CITY OF TUKWILA, ITS OFFICERS. AGENTS AND EMPLOYEES. PRELIMINARY PLAT NO. L98 -0019 FINAL PLAT NO. L2000 -026 6 FOSTER HEIGHTS A PORTION OF THE NE1 /4, SEC.22, T.23N., R.4E. KING COUNTY, WASHINGTON CITY OF TUKWILA L Nt ai 0 I S %UPE O Y W y� 4 PARCEL 'D' T.L. 0040000560 i PREPARED BY DRAWN BYI S 87'52'34 E 126.11' S 8 7'5 5' 58 " VICINITY MAP NTS S. 144TH ST. I T__ N 0 S 87'51'26 E PARCEL 'A' T.L. 0040000539 PARCEL 'B' T.L 0040000550 PARCEL 'C' T.L. 0040000554 315.06' 189.20' 0 0 7 • S. 146TH ST. INSTRUMENTATION INSTRUMENT USED: FiVE SECOND TOTAL STATION. FIELD SURVEY CONTROL WAS BY CLOSED TRAVERSE LOOPS, MINIMUM WAS 1: 22000. INDEX LOCATION: THE NE1 /4 OF SEC. 22, T. 23 N., R. 4 E., W.M. B ASIS OF BEARING: NORTH LINE OF NORTHEAST QUARTER N 87'49'18' W PER R.O.S. RECORDED IN VOLUME 30 OF SURVEYS. PAGE 57 S 87 '53'42" E 189.29' S 87 '54'50" 189.20' CLOSURE OF LOOPS Zalma ENGINEERS & S U R V E Y O R S 100 FRONT STREET SOUTH iSSAQUAH, WASHINGTON 98027 (425) 392 - 0250 JOB NO. 1736 -001 1736 -1 FP.DWG CHECKED BYI DATE' SHEET' MM WSH 6 -13 -01 2 OF 3 VOL, i PG. v) O 0 w 0 6 � 4 4 3 RECEIVED JUL 1 9 2001 TUKWILA PUBLIC WORKS 4 'I r WITH COPPER PLUG & PUNCH MARK J 04 NO OF LiNE (ENCASED) VISITED 7 -22 -97 1 318.09 FD 4 - x4 - L.C4NC. MCN. WITH COPPER PLUG & PUNCH MARK (ENCASED) 20 SANITARY SEINER F 2" BRASS DISC IN CONC. WITH PUNCH MARK (ENCASED) VISITED 7 -22 -97 WEST LINE LOT 1SOCk 4 ADAMS S HOME TRACTS NORTH LINE LOT 14 BLOCK 4 r ADAMS HOME TRACTS SIDEWALK EASEMENT I SEF NOTE PAGE 2 SEE NOTE 7 i �t FADE 2 ! 5' WATER ESM'T DEDICATED TO - - J _- 1 _ wD 125, TYP PRELIMINARY PLAT NO. L98-0019 FINAL PLAT NO. L2000 -026 10' UTILITY I EASEMENT 1 10' SANITARY . SE xER E SM _ _ _RECCRDING NO j;,, 19990812000314 I SEE NOTE 8ONPAGE 2 I I OJW JV. f t. I\ \ r 5" WATER ESM'T SEE NOTE 4 ON PAGE 2 A PORTION OF THE NE1 /4, $EC.22, T.23N., R.4E. KING COUNTY, WASHINGTON CITY OF TUKWILA 90.76 SEE NOTE 5 &SON SHEET 2 OF 3 OF THIS PLAT. 6 500 SO F T Q o SEE NOTE 4 2 ON PACE 2 5' PRIVATE i ! i DRAINAGE EASEMENT I 7 -1 3 FOSTER HEIGHTS [ NORTH LINE w1/2 LOT 10 BLO 4 ADAMS HOME TRACTS S 8751 E 189.46 .35.82 „ , SEE NOT: 5 ON PAGE 2 \ \c a , 15' POWER ESM'T \ \ TO JLAI ILE C ITY / 5' PRIVATE NAGE J '\ LIGHT - UPON P / uRAi ).1 C ' EASEMENT \ i 14 N� 4 i 6500 SC. FT _ _ - , \ \SEE NOTE 5 & 8 ON PAGE � , �'+ 15" POWER ESM' / SOUTH 145th STREET , ESM'T PER PECCUROIN0 NO. 1 999.3720003;44 y -- cit.� AtIV - - - - 5" PRIVATE DRAINAGE 6500 SO. FT SEE NOTE 4 ON PACE 2 ;o BASIS OF 9EARING 10' PRIVATE I 62.88 SEE NOTE 5 Z ON PAGE 2 0 12 IJ 5547 S0. FT. 79 v u. DRAINAGE EASEMENT 8 9 \ \ - r 6533 SO. FT. 1 6500 S0. FT. I SEE NOTE 3 ON PAGE 10' SANITARY T i SEE NOTE 9 ON PAGE 2 '" SEWER ESM'T � _ -r 5' RECORDING NO 199908120003141 60"88 - / _ 2 3.3 6500 S0. FT. - `� 7 �i 60.63 S 8836'57" E 2 6500 SO. FT I SEE NOTE 7 PAGE 2 10' SANITARY SEWER ESM'T RECORDING NO 199908 1 ! 6500 SO. FT. SEE NOTE 7 PAGE 2 DRAWN BY' MM M WATER ES 68.21 S 87 £ 315.06 DEDICATED TO THE PUBLIC FOR ROAD PURPOSES UPON THE RECORDING OF THIS PLA S 146TH S 1'O' UTILITY • EASE SENT ` ' '\ SANITARY SEWER EASEMENTS AS SHOWN ARE PEP RECORDING NUMBER 199903! 200031 4 W n 0 2 _.EAST t INE w1/2 LOT 13 BLOCK 4 / ADAMS HOME TRACTS 0 20 40 LEGEND =OUNO MONu'MENr AS NOTED ® MONUMENT To BE SET ROS RECORD OF SI;RvEY RECORDED ■N VOLUME 30 OF SURVEYS, PAGE 57 OPIC:NAL _OT LINES SET REBAP AND CAP. LS# ; EAST LINE OF W1 /2 LOTS 10 AND 11 BLOCK 4 ADAMS HOME TRACTS CURVE TABLE NO DELTA RADIUS LENGTH C1 9000'00" 25.00 .39.27 C2 72 25.00 31.76 C3 .37'38'36 46.00 30.22 C4 51'42'32" 46.00 41.51 C5 73'31'21" 46.00 59.03 C6 62'49'32" 46.00 50.44 C7 40'43'38" 46.00 32.70 CS 13'37'54" 25.00 5.95 C9 90'00'00" 25.00 39.27 C12 89 25.00 38.97 CI, 6211'01" 25.00 27.13 LINE TABLE N(;. BEARING DISTANCE LI S 8832'13' E 5.00 L2 S 25'42'41" E ' 16.9 7 L.: S 25'42'41" E 7.52 L4 S 25'42'41" C 3.46 NORTH LINE I 2 BLOC', s\D aIJR r,:tu_ :PA;_TS 15' IiP.L;TY ISM'T REC. NO 1 ;9903 1 2000315 L wa «o ESU'T S d 189.29 132. 1:5 PRIVATE ORAINA. • 11 EASEMENT I 6500 SO. FT 650 2 NOTE 3 ON RAG, 1 t 1 I 2 NOTE 6 O N SAC:. NOTE ! 3 JN PAOE 2 112.54 • 1-' ` 8754'50' E 139.36 - 6503 S0 FT. 10 w 10. SAN. SEWER EASEMENT ° - ` n aECORDING NO.1999031 _2000314 1 \ SEE NOTE 3 ON PAGE 2 SEE NOTE 6 ON PACE 2 \ SEE NOTE 13 ON PAGE 2 120.99 5 8 E 189.20 SOUTH LINE LOT 12 BLOCK 4 ADAMS laCMC 'PACTS CHECKED BY1 WSH II ED. CONC. MON. MTH LEAD & PUNCH MARK (ENCASED) VISITED 7 -22 -97 PREPARED BY Balma & Holmberg Inc. 25' PUBLIC DRAINAGE EASEM'EN'T .AND PRIVATE TREE REPLACMENT AND VAULT SCREENING EASEM N T _ I CALCULATED REEVED JUL 1 P 710' TUKWILA PUBLIC WORKS E N G I N t E R 5 & 3 I1 R V E Y O R S 100 FRONT STREET SOUTH ISSAQUAH, WASHINGTON 98027 (425) 392 - 0250 JOB NO. 1736 -001 1736 -1 FP.DwG DATE' SHEET' 6 -13 -01 3 OF 3 INTERSECTION POSITION 4 y • DESIGNED TJR DRAWN JEF CHECKED TJR T� SERIACE LOT 15 OILY - I I 45' D.I. C142 ESIAT 1 \ 1 \ 1 -8" 45' BftsID (NJ) W/ THRUST BLOCKING a WATVP cwt 1 \ 1 I 5' WAiER ESMT. I- DEDICATED TO I WD 126, TYP. 16 -BOX MAILBOX RAkCK WITH MINIMUM 5' CLEARANCE BETWOrN MAILBOX & BACK OF IDEWAI$< -SEE DETAIL WOOD FEN / POSH EXIST. WET O`Bi' D ABI4NDO D PER .O.E. jEQUI MENTS I 9 TF1 AFFIC EARING I LID ON METIER BOX TOP OF CURB = 464.23± 1 -FIRE HYDRANT PER DISTRICT STANDARDS 1 -8 "x6" TEE (MJxFL) 1 -6" GATE VALVE (FL) W/ THRUST BLOCKING 1 -FIRE HYDRANT PER DISTRICT STANDARDS 1 -8 "x6" TEE (MJxFL) 1 -6" GATE VALVE (FL) W/ THRUST BLOCKING TYPE III BARRICADE 1 -8" TEE (FL) ,It ! 2 -8" GATE VALVE (FLxMJ) ' 1 -8" ADAPTER (FLxMJ) W/ THRUST BLOCKING I REVISED PER PACE REVIEW S FINAL Gn1RBLTE4 P IAN .S 2 REVISED PER PACE & CITY REVIEW REVISION 87'24" iy 126.11' O 1 -8" TAPPING TEE (FL) 1 -8" TAPPING GATE VALVE (FLxMJ) WI THRUST BLOCKING ► /r�kn 4 ow TJ R X21 /II RGH TJR JEF TJR DATE by APP'D S /146TH 1 HLSE_ PLANS ARL "AS- BUILT" AND THE INFORMATION SHOWN ACCURATELY REFLECTS EXISTING FIELD CONDITIONS AS OF THIS DATE:: s -z000 G11� WILLIAM SHUPE H(II MBERG PLS 11332 1 -FIRE HYDRANT PER DISTRICT STANDARDS 1 -8 "x6" TEE ( MJxFL) 1 -8" PLUG (MJ) 1 -6" GATE VALVE (FL) W/ THRUST BLOCKING 1. ALL MATERIAL SPECIFICATIONS AND CONSTRUCTION TECHNIQUES SHALL CONFORM TO THE REQUIREMENTS OF WATER DISTRICT 125. 2. ALL LOTS SHALL HAVE INDIVIDUAL PRV'S, INSTALLED ON THE DOWNSTREAM SIDE OF THE METERS. 3. THE LOT 15 RESIDENCE SHALL BE PROVIDED WITH A SPRINKLER SYSTEM. 1 -8" VERTICAL 22.5' BEND (MJ) WLTHRUST BLOCKING I (RELOATE \EXISTNG ' . (FIRE' HYDRA,NT\ TO I BEHIND SID WA SCALE SURVEY TEAM RID ROOK 1 -4 "x8" TEE (FLxMJ) 1 -8" GATE VALVE (FLxMJ) 1 -4 "x8" REDUCER (FL) W/ THRUST BLOCKING ABANDON EXISTING WATER METER & PLUG CORP STOP ( ) AT THE MAIN JUNE 16, 1999 EXPIRES 11 /30/00 OWNER TRIDOR INC. ATTN. SCOTT WIKLOF 2226 EWOTT SEATTLE, WA 98121 206/443 - 7735 LEGAL DESCRIPTION LOTS 12 AND 14, TOGETHER WITH THE WEST HALF OF LOTS 10, 11 AND 13, ALL IN BLOCK 4, PLAT OF ADAMS HOME TRACTS, RECORDED IN VOLUME 11 OF PLATS, PAGE 31, RECORDS OF KING COUNTY, WASHINGTON. FIELD SURVEY CONTROL WAS BY CLOSED TRAVERSE LOOPS, MINIMUM CLOSURE OF LOOPS WAS 1:22,000. IN ACCORDANCE WITH WAC 332 - 130 -100. DATUM ASSUMED DATUM WATER DISTRICT NO.125 STANDARD NOTES: 1. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF LOCATION SHOWN AND FOR DISCOVERY OF POSSIBLE ADDITIONAL UTILITIES NOT SHOWN SO AS TO AVOID DAMAGE OR DISTURBANCE. THE CONTRACTOR SHALL CONTACT THE UTILITIES UNDERGROUND LOCATION CENTER (1- 800 - 424 -5555) PRIOR TO CONSTRUCTION. THE OWNER OR HIS REPRESENTATIVE SHALL BE CONTACTED IF A UTILITY CONFLICT EXISTS. 2. CONTRACTOR SHALL NOTIFY DISTRICT ENGINEER A MINIMUM OF 48 HOURS IN ADVANCE OF ALL REQUESTS FOR STAKING, TESTING OR INSPECTION. 3. CONTRACTOR IS RESPONSIBLE FOR CONTROL AT THE TIME OF STAKING. 4. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR APPROVAL WHERE REQUIRED BY THE DETAIL SPECIFICATIONS AND FOR VARIATION FROM THE ENGINEER'S DESIGN. 5. CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, AND WD #125 SPECIFICATIONS. 6. CONTRACTOR SHALL FURNISH ALL MATERIALS. 7. ALL WATERMAIN PIPE SHALL BE DUCTILE IRON CLASS 52, PUSH -ON JOINT OR MECHANICAL JOINT, CEMENT LINED (ANSI A21.4), EXTERIOR COATED WITH COAL TAR VARNISH. INSTALLATION TO BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ALL FITTINGS SHALL BE CAST IRON AND SHALL CONFORM TO APPLICABLE PORTIONS OF ANSI STANDARD A21.10, A21.11, 816.2, B16.4 AND A21.53, WITH A MINIMUM PRESSURE RATING OF 150 PSI AND WILL BE CEMENT LINED. 8. ALL GATE VALVES TO BE MUELLER. ALL HYDRANTS TO BE MUELLER. 9. CUT -INS AND LIVE TAPS TO BE MADE BY CONTRACTOR. WD #125 SUPERINTENDENT AND ENGINEER MUST BE NOTIFIED 48 HOURS IN ADVANCE. 10. CAST IRON MECHANICAL JOINT SLEEVE COUPLINGS REQUIRED. 11. TAPPING SLEEVES SHALL BE MUELLER CAST IRON, JCM EPDXY COATED STEEL, OR ROMAC SST WITH STAINLESS STEEL FLANGE. 12. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING PIPE TYPES AND SIZES FOR COUPLINGS, CONNECTIONS, CUT -INS, AND LIVE TAPS. 13. 3 1/2 FOOT MINIMUM COVER OVER ALL WATERMAIN PIPES. 14. DEVELOPER TO PAY FOR STATE, COUNTY AND CITY INSPECTION FEES. 15. ALL METER LOCATIONS TO BE COORDINATED WITH WATER DISTRICT NO. 125 SUPERINTENDENT. 16. ALL EXISTING FIRE HYDRANTS AND MAINS TO BE OPERATIONAL PRIOR TO COMMENCEMENT OF CONSTRUCTION. 17. NO CHANGES ARE TO BE MADE WITHOUT WRITTEN APPROVAL BY THE WD #125 SUPERINTENDENT OR DISTRICT ENGINEER. 18. REFER TO WD #125 CONDITIONS AND STANDARDS, FOR ALL REMAINING NOTES AND DETAILS. 19. PROVIDE 3/4" SERVICE LINE AND TAP CONNECTIONS FOR EACH EXISTING WATER METER. 20. MAXIMUM ALLOWABLE OPEN TRENCH SHALL BE 80'. 21. STOCK PILES SHALL BE COVERED DURING ALL PERIODS OF PRECIPITATION. 22. MODIFIED PROCTOR COMPACTION AND MOISTURE CONTROL TEST REQUIRED AND COPIES OF TEST REPORTS SUBMITTED TO THE DISTRICT ENGINEER. ALL COMPACTION UNDER PAVED AND TRAFFIC AREAS SHALL BE 95% MAXIMUM DENSITY MODIFIED PROCTOR PER ASTM D -1557. ALL OTHER AREAS TO BE 90% MAXIMUM DENSITY MODIFIED PROCTOR. 23. ALL VALVES, FIRE HYDRANTS AND SERVICES TO THE METER STOP TO BE INCLUDED AS PART OF ALL PRESSURE AND PURITY TESTS. NO EXCEPTIONS. 24. TRAFFIC CONTROL SHALL BE IN ACCORDANCE WITH CITY OF TUKWILA REQUIREMENTS. 25. ALL PIPE AND APPURTENANCES TO BE TESTED WITHIN 10 FEET OF ANY CONNECTION POINTS UNLESS OTHERWISE APPROVED BY ENGINEER. 26. CONCRETE THRUST BLOCKING SHALL BE PROVIDED AT ALL BENDS, TEES, VALVES OR OTHER APPURTENANCES WHERE INTERNAL FORCES REQUIRE RESTRAINT. BLOCKING SHALL BE IN ACCORDANCE WITH WATER DISTRICT NO. 125 STANDARDS. 27. THE TESTING AND DISINFECTION OF THE WATER SYSTEM SHALL BE WITNESSED EILIsygg NO 125. \ U fl UNE, ITS corny Call before you d�9• 1- 800 - 424 -5555 UNDERGROUND SERVICE USA VICINITY MAP NTS NOTE: - SITE TRIDOR INC. FOSTER HEIGHTS WATER EXTENSION WATER PLAN EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER- GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG: 1 - 800 - 424 - 5555 . JOB NO. 99154 -80 4 KING COUNTY WATER DISTRICT NO. 125 CPU F1LE t 1422 -4WI A.DWG 0 +43.47 STREET LIGHT (TYP.) FIRE • HYDRANT 5' PRIVA DRAINAGE ESMT 5' PRIVATE DRAINAGE EASEMENT • 5' WATER ESMT. DEDICATED TO WD 125, TYP. -BOX MAILBOX RACK TH MINIMUM LEARANCE BETWEEN BOX & BACK OF SIDEWALK DETAIL 5' WALK MENT LOT LINE TO BE 'ELIMINATED 3 4 * - tj WOOD FENCE POST!. POST • 5' PRIVATE DRAINAGE ESMT 8" SE WE PRIVATE C8# 14 PRIVATE , MIN. 20' WIDE DRIVEWAY FOR FIRE DEPARTMENT TURNAROUND "NO PARKING ON ASPHALT" SIGNS ALONG WALKWAY ® 100' SPACING, TYP. WIDEN EXISTING ASPHALT EXISTING tt ROAD 5' MIN. FOR PEDESTRIAN T AS IO WALKWAY TO 46TH AVE S. - SEE DETAIL ENTERING SIGHT DISTANCE 438 FEET LOOKING WEST 323 FEET LOOKING EAST (INSTRUMENT HEIGHT = 3.50 FEET, MEASURED 10 FEET OFF EDGE OF ASPHALT, OBJECT HEIGHT = 4.25 FEET) POSTED SPEED LIMIT = 25 MPH STA. 3 +25 END IMPROVEMENTS TOP OF CURB-464.23± f. , RELOCATE EXISTING FENCE AS NEEDED, - TYP. TYPE III BARRICADE B 8" THERMOPLASTIC EDGE ARATE PEDESTRIAN •o FROM AUTOS . TO CITY OF .1UKWILA FOSTER HEIGHTS YARD - CESFIRE S HYDRANT ESMT EXISTING • Call before you DIg. 1 -500- 424 -5555 UNDERGROUND SERVICE (USA NOTE: THESE PLANS ARE "AS- BUILT" AND THE INFORMATION SHOWN ACCURATELY REFLECTS EXISTING FIELD CONDITIONS AS OF THIS WILLIAM SHUPE HOL M BE �332 EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER- GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG: 1 -800- 424 -5555. 4 SHEET 7 of 8 JOB NO. 1422 -004 DRAVING NO. 1422 - 4C1 - -4 'ENCL "NO PARKING ON ASPHALT" SIGNS ALONG WALKWAY ® 100' SPACING, TYP. 1_ STA. 3 +00 ENTERING SIGHT DISTANCE 438 FEET LOOKING WEST 323 FEET LOOKING EAST (INSTRUMENT HEIGHT = 3.50 FEET, MEASURED 10 FEET OFF EDGE OF ASPHALT, OBJECT HEIGHT = 4.25 FEET) POSTED SPEED LIMIT = 25 MPH TYPE III BARRICADEi STA. 3+25 END I \\ \ IMPROVEMENTS STA. 3+10, 27'LT CURB INLET BOX RIM =46374 463, IN V= 4'56.99.-3 END ROOCERY TOP =466.0 TOE =463.2 TOP= 468.0 TOE =464.2 TOP OF CURB = 464.23± TOP =468.9 TOE =465.0 S -A. 1+ 50 -BEGIN ROCKERY TOP =469.0 TOE =466.5 RELOCATE UTIUTIES AS NEEDED. TYP. RELOCATE EXISTING FENCE AS HEEDED. - WIDEN EXISTING ASPHALT TYP EXISTING ROAD 5' MIN. FOR PEDESTRIAN _ T AS WALKWAY TO 46TH AVE S. TYP. - SEE DETAIL ita 1 1 GB R 1Ay �'�73.eq guy ti t7 /. 4.4 o . 'C 2C STA. 3+24, 13.25 RT CB# 12, TYPE I RIM= 4 744{,1.7f. INV =4587634511.78 32' --12" SD 0 4 -6911 2.81 %, � STA. 1 2 +92.4. 13.25'RT i CB# `1, TYPE I i I RIM=4C2.31 I 4NyZ INV= 4 ` \ WHEELCHAIR i AMP, TYP. `...k � 44 ' 2" S D b & ' 1 MILIMIL\1III AIMI IP - - ___ tyIIIIINKi i • - - -- - _ 7 - STA. 0 +49\ 13.2 \ ' T cst 10, TYPE I I W / VANED (RATE DRAT AGE EMT I ` RIM 6Fi 4$8 .451. 4 1 ` y�/ VANE "GRA STREE INV = 461-26 434. IGH Rlld - 110.0 L T ' ; (TYP.)‘ WATER . 1 EDICAT E O \ 6 w 125, ". \ \ \ ` 1 5' WAN1ER ESM T. DEDICATED TO II WD 125. TYP. 1 BOX MAILBOX Ri\CK TH MINIMUM ARAN CE BETWEEN OX do BACK IDEWALII( DETAIL 101 '-12" HDPP D 1C 14{1449 ; i9. I W /(2) PIPE ANCHORS PACED ALONG PIPE I SEE DETAIL I \ . 1 I 1 1101 EXIST,. WE Td if I 1 AB AND 1 O14ED PER O.E. REQUI MENTIS [ AIN AGE E I l _ RIVA+E CB# 6 \ W/ LOOKING G 1tIM = 4 7.00 INV= 4.2a -QG 95 \ I `� PRIVATE 1 I CB# 13, TYPE 11 r WI LOCKING VANED GRATFo RIM =411 0 " THERMOPLASTI MIN. 20 MADE DRIVEWAX' I 1 ( / I EXIST: CB RIM =377.7 INV= 5.0 SCALE 1' = 30' ° 1O CITY CIF 8" ADS N -12 TIGHTUNE I FROM ROCKERY DRAIN 0 1% MAIN. FOSTER HEIGHTS 146TH ° ST. CAU ON TO SD C VERIFY C R,M : 454. z /NV c 430.61 ATERLINE PRIOR STA. 2 +49.89 STRUCTION TO CB# 12, TYPE I ARANCE W/ VANED GRATE RIM = 443+6± ;; - < - (MATCH PAVING) CB# 7, TYPE I WI THROUGH CURB INLET RIM = 4'396 4 ,4. /S INV= 4'8-60 434 .4E CB# 5, TYPE II -54" W/ SOLID LOCKING UD STA. 2 +74, 18.5'RT RIM= 42i.GG 4Z(..19 INV = 44'&66 4 -17.63 N 87'53'42" V - *#•4-16 --�-- !d 0 THESE PLANS ARE "AS- BUILT" AND THE INFORMATION SHOWN ACCURATELY REFLECTS EXISTING FIELD CONDITIONS AS OF THIS DATE: !Z- O5 -z°OO 'WILLIAM M SHUPE SHUPE HOL ER PLS 332 CB# 4, TYPE II - 48 WI SOUD LOCKING LID RIM = 43.66± 413 INV =464,13 408 4 15' UTILITY `[ EASEMENT CONSTRUCT/REBUILD ROCKLINED DITCH -SEE DETAIL CB# 3, TYPE II -48" rL WI SOUD LOCKING LID RIM =38696 INV= 388-414W) INV =3 4A(S) I Zo 4.24'^ 12" HDPP 0 2 W/ (2) PIPE ANCHORS SPACED ALONG PIPE EXISTING 12 DETENTION/WATER QUALITY VAULT - SEE DETAIL • CB# 2, TYPE II -48" RIM = 38+46± 3 79.73 INV= 376, 67(12 "W) 3 76.33 INV =3 73.20(6 "dc12 "E)3 73 CB# 1, TYPE I CONSTRUCT OVER EXIST. SD RIM = 3464 375./I (MATCH ROAD) INV =374 (VERIFY 31Z.74 PRIOR TO VAULT CONSTRUCTION) Call before you D� 9. 1- 800 - 424 -5555 UNDERGROUND SERVICE (USA) OWNER HAPPY VALLEY LAND CO. P.O. BOX 1324 ISSAQUAH, WA 98027 INSTRUMENTATION NOTE VICINITY MAP NTS INDEX 1 ROAD /STORM /GRADING PLAN 2 ROAD /STORM PROFILES 3 ROAD /STORM PROFILES 4 OFFSITE WALKWAY 5 NOTES /DETAILS 6 STANDARD DETAILS 7 COMPOSITE UTILITY PLAN 8 T.E.S.C. PLAN INSTRUMENT USED: 5 SECOND ELECTRONIC DISTANCE MEASURING UNIT. FIELD SURVEY CONTROL WAS BY CLOSED TRA\ERSE LOOPS, MINIMUM CLOSURE OF LOOPS WAS 1:22,000, IN ACCORDANCE WITH WAC 332 - 130 -100. 1. UNLESS OTHERWISE SPECIFIED, ALL STORM PIPE (SD) SHALL BE ADS N -12 OR EQUAL. 2. STREET LIGHT MATERIALS AND CONSTRUCTION SHALL MEET CITY OF TUKWILA STANDARDS. 3. INTERIOR ROADS SHALL HAVE THERMOPLASTIC CROSSWALK AND STOP BAR STRIPING AND CENTERLINE BUTTONS. 4. INSTALL STREET NAME SIGNS, STOP SIGNS, ETC. PER CITY OF TUKWILA STANDARDS. APPROXIMATE CUT = 1.150 CUBIC YARDS APPROXIMATE FILL = 400 CUBIC YARDS LEGAL DESCRIPTION LOTS 12 AND 14, TOGETHER WITH THE WEST HALF OF LOTS 10, 11 AND 13, ALL IN BLOCK 4, PLAT OF ADAMS HOME TRACTS, RECORDED IN VOLUME 11 OF PLATS, PAGE 31, RECORDS OF KING COUNTY, WASHINGTON. caost A \� ORIMC IMOONNOUID MAITY UNIX rYS OOMY NOTE: EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER- GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG: 1 -800- 424 - 5555. DATE 2/10/98 JOB NO, 1422 -004 DRAWING NO.1422 -4C1 SHEET Q File: D 02 -0051 35mm Drawing #1 11 X 17 /MINTED ON NO. 1000N CIEARPRINT • ref: Preliminary Plat Map by Baima & Holmberg Inc. dated 9/12/97, reduced scale 1" =.60' I 15' EASEMENT drainage/seepage GEOSPECTRUM CONSULTANTS, INC. Proj. No.98 -103 SITE EXPLORATIONS PLAN Proposed Foster Heights Development South 146th Street & 51st Avenue South Tukwila, Washington Date 2/98 Figure