Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D02-061 - BUSINESS INTERIORS NORTHWEST
D02-061 Business Interiors NW 10838 East Marginal Wy S fy. Public Works Activities: doc: Devperm City of Tukwila ¶RE?RINT 6• Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 DEVELOPMENT PERMIT Parcel No.: 0323049164 Permit Number: D02 -061 Address: 10838 EAST MARGINAL WY S TUKW Issue Date: 04/18/2002 Suite No: Permit Expires On: 12/08/2002 Tenant: Name: BUSINESS INTERIORS NORTHWEST Address: 10838 EAST MARGINAL WY S, TUKWILA, WA Owner: Name: MCCONKEY DEVELOPMENT CO Address: 3006 NORTHUP WY #101, BELLEVUE WA Contact Person: Name: KELLY VAN GELDER Address: SKB ARCHITECTS, 1403 THIRD AVENUE Contractor: Name: SEATTLE CONST RESOURCES INC Address: 1414 ELLIOTT AV W, SEATTLE, WA Contractor License No: SEATTCR101 BZ 002 -061 Phone: Phone: 206 903 -0575 Phone: 206 - 282 -7500 Expiration Date: 02/05/2004 DESCRIPTION OF WORK: NON - STRUCTURAL INTERI9OR TENANT IMPROVEMENTS TO 8,524 SQ FEET OF EXISTING OFFICE/WAREHOUSE SPACE Value of Construction: $170,480.00 Fees Collected: $2,300.23 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: Occupancy per UBC: 0016 Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: n Public: n Storm Drainage: N Street Use: N Water Main Extension: N Private: n Public: n Water Meter: Channelization / Striping: ** Continued Next Page ** Printed: 06 -20 -2002 z ~w J U U O U, 0 W � 1-- CO w O u_Q Z � i-0 U 0 I- WW H - IL. O u1 0 0- O I- z Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constr tion or the pprfcrrn nce of work. I am authorized to sign and obtain this development permit. Signature: ►4 J Print Name: `5 E \j �— P1 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: Devperm City of Tukwila 002 -061 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 / cW mA Gi fi a) Date: Date: 6 • ZD • 2 Printed: 06 -20 -2002 City of'1'ukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0323049164 Permit Number: D02 -061 Address: 10838 EAST MARGINAL WY S TUKW Issue Date: 04/18/2002 Suite No: Permit Expires On: 10/15/2002 Tenant: Name: BUSINESS INTERIORS NORTHWEST Address: 10838 EAST MARGINAL WY S, TUKWILA, WA Owner: Name: MCCONKEY DEVELOPMENT CO Address: 3006 NORTHUP WY #101, BELLEVUE WA Contact Person: Name: KELLY VAN GELDER Address: SKB ARCHITECTS, 1403 THIRD AVENUE Contractor: Name: SEATTLE CONSTRUCTION SRVCS INC Address: 165 NE JUNIPER ST 100, ISSAQUAH, WA Contractor License No: SEATTCS11 ONG DEVELOPMENT PERMIT Phone: Phone: 206 903 -0575 Phone: 425 - 837 -9720 Expiration Date: 08/01/2002 DESCRIPTION OF WORK: NON - STRUCTURAL INTERI9OR TENANT IMPROVEMENTS TO 8,524 SQ FEET OF EXISTING OFFICE/WAREHOUSE SPACE Value of Construction: $170,480.00 Fees Collected: $2,300.23 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: Occupancy per UBC: 0016 Public Works Activities: Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: n Public: n Storm Drainage: N Street Use: N Water Main Extension: N Private: n Public: n Water Meter: Channelization / Striping: ** Continued Next Page ** doc: Devperm D02 -061 Printed: 04 -18 -2002 z ~z w C g 6 U0 U) ILI J H w Q = a w z � F— 0 Z F— LU O � F- W W H0 = O w z P. 0 z Permit Center Authorized Signature: K C I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or tlleperf rmance of work. I am authorized to sign and obtain this development permit. Signature: Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D02 -061 Date: Printed: 04 -18 -2002 doc: Conditions City of'i PERMIT CONDITIONS D02 -061 _ 'aoyFy.,y' Sr V:.i.i:I.i:Lex9M Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0323049164 Permit Number: D02 -061 Address: 10838 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 03/06/2002 Tenant: BUSINESS INTERIORS NORTHWEST Issue Date: 04/18/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All mechanical work shall be under separate permit issued by the City of Tukwila. 6: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 7: When special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name, permit number and type of inspection being performed. 8: The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspector's knowledge, in conformance with approved plans and specifications and the applicable workmanship provisions of the UBC. 9: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 10: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 11: There shall be no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building Inspector. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 14: Maintain fire extinguisher coverage throughout. 15: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 16: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) 18: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 19: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or Printed: 04 -18 -2002 z ~ w �QQ JU 00 N D • UJ J H W LL. w O �Q = • a Z F. I— O Z I— w • w U O - C) F- w • w O ui U N = O z 4 doc: Conditions City of 'Tukwila 002 -061 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 adding sprinkler heads. 20: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 21: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 22: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 23: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) 24: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 25: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575- 4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. GG Date: 4 tP Al— Signature: 1 L �' �C� Date. Print Name: 1 col L —AcHf— — Printed: 04 -18 -2002 ...x. -u ++ awv: qv��: �wr. R.^ xa* r^+t+. �r "t.• ^'H(YC� °nfi16•Jt* z 1 6 J 00 W I H w00 ¢ a Z � H O Z I— U O CP- O I- w W O .. Z F O Z Project Name/Tenant: Street Address: Engineer. j Phone: Street Address: Description of work to be done: Existing use: ❑ Retaii in Restaurant • Mufti- family ,I' Warehouse ❑Hospital 1:3 Church C:1 LM Manufacturing ' ❑ Motel/Hotel Office ❑ School/College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family L W rehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel/Hotel Mr . ❑ School/Colle a a/University ❑ Other _. Will there be a change of use? ❑ yes 11.' no if yes, extent of change: (Attach additional sheaf if necessary) I X I ST1 144 i PACKS --- O CFF ftwe Will there be rack storage? O es ❑ no Existing tire protection features: I,id sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: . 5 existing Area of Construction: (sq. ft.) 6 5 2 Will there be storage of flammableicombustible heza dous material in the building? ❑ yes 2 no Attach list of materials and stor to location on separate 81/2 X 11 paper indicating quantities 6 Material Safe Data Sheet s _, Permit Cent 6300 Southcente. dlvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Date application Accept* CTPERMIT.DOC 1%29/97 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. • APPW gtJi:ii ; iuESTiFORPtlby :yl�ofi , j lclruP g �� y PI , �ltl 'rog�. ? A d d i t l o r t a l • r e v l ' e w s m a y b e d a t e r m f n e i ) ' f ! ' e . P . a b l c . W o r k s p arkmaiii : ; ' • • ❑ ChannellzationlStriping ❑ Curb cut/Access/Sidewalk Cl Fiood Control Zone ❑ Hauling ❑ Fire Loop/Hydrant (main to Vault)il• Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer ft: - ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use Cl Water Main Extension 0 Private 0 Public Cl Water Meter /Exempt H• Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent If Size(s): ❑ Water Meter Temp it Size(s): EsL quantity gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant This figure will be reviewed and Is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the data of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Codo (current edition). No application shat be extended more than once. Date application expires; Appticatr ke by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM FEB 28 '02 08 :59AM TUKWILA DCD /PW ALL COMMERCIAL /Ii4U ' .4MILY TENANT IMPROVEMENT /,E1LTERA PERMIT APPLICATIONS UST BE SUBMITTED WITH THE FOLLOWIN : ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER D ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN > BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SU iTED ❑ Complete Legal Description V Metro: Non - Residential Sewer Use Certification if there is a change In the amount of plumbing fixtures ���� �,�, (Form 1-1-13). Business Declaration required (Form H -10).X Medictn ICA,I an al ersepou t. t r e v "'t^ Four (4) sets of working drawings (five(5) sets for structural work), which include ❑ Site Plan (including existing fire hydrant location(s) VI. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions V4. Location of driveways, parking, loading & service areas -5: Recycle collection location and area calculations (change of use only) -6t Location and screening of outdoor storage (change of use only) 7,. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries , e: Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) -9: Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identiify by size and species which are to be removed and saved 4O. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and.setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil/slte plan information required for Public Works Review {Form H- �f 9). ' ❑ Do Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of ❑/ M any hazardous materials; dimeltslons of proposed tenant space. Vicinity Map showing location of site l J,D ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan Identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of � / rack. Structural calculations are required for rack storage eight feet and over. ❑ Ell Olyj Indicate proposed construction of tenant space or addition and walls being demolished ❑ Construction details ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations In structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will.melt or , ,� rci �—t exceed sprinkler s; dem design criteria as identified by the Fire Department. Median tat) t't'►'1 Li�P� v �tC., ❑ Washington State Lon- faesidentiai Energy Code Data shall be noted on the construction drawings. ^ I Yi'! ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). d Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other 6411 t land use or SEPA decisions. ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296.4787. (Form 11-5) C3 Public of Washington State Department of Labor and Industries Valid Contractor's License. If no # S FArrCg. ` 0 1 Baz contractor has been selected at time of application a copy of this license will be required before the permit is Issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration". BulldIn drVt �el gi► �l +t 1 =1ftF �eiap�a othec:MO.00 writ; 9tetdbtlhnbetOgih s r rrahlraski ricer6oB: ll by the State o'E Wa�hTh tetf Hd ii? a7ef)ec ro kihq f ropei,I ipstBlioti " ttit;';apet114a gu l ' ; i"ditnI1 'pfs rldN . 'f] obtain tha psrtirik.wl/i balfilai1ud ai paalli%s.s 31biiNal • I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THiS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMI1 CTPERMIT.DOC 1/29/97 P.3,3 Payee: SEATTLE CONSTRUCTION TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt City of Tukwila Current Pmts Amount 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PLAN CHECK — NONRES RECEIPT Parcel No.: 0323049164 Permit Number: D02 -061 Address: 10838 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 03/06/2002 Applicant: BUSINESS INTERIORS NORTHWEST Issue Date: Receipt No.: R020000311 Payment Amount: 904.38 Initials: SKS Payment Date: 03/06/2002 11:54 AM User ID: 1165 Balance: $1,395.85 Type Method Description Payment Check 0018426 904.38 Description Account Code 000/345.830 904.38 Total: 904.38 4546 03/07 9716 TOTAL 904.: Printed: 03 -06 -2002 Payee: BUSINESS INTERIORS NW TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt City of 1 ukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Current Pmts Amount RECEIPT Parcel No.: 0323049164 Permit Number: D02 -061 Address: 10838 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 03/06/2002 Applicant: BUSINESS INTERIORS NORTHWEST Issue Date: Receipt No.: R020000514 Payment Amount: 1,395.85 Initials: KAS Payment Date: 04/18/2002 03:56 PM User ID: 1684 Balance: $0.00 Type Method Description Payment Check 79785 1,395.85 Description Account Code BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 1,391.35 4.50 Total: 1,395.85 r.-;yr:i.'r 1)4/19 9716 TOTAL AL 9 .F. Printed: 04 -18 -2002 Special instructions: - INSPECTION NO. 'CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION RECORI Retain a coprwith permn PERMIT NO. (206)431-3670 Approved per applicable codes. ri Corrections required prior to approval. COMMENTS: Date: [1] $47.00 REINSPECTIO E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: 'INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECOR Retain a copy with permit 6300 Southcenter Blvd, #100, Tukwila, WA 98188' PERMIT NO. (206)431 -3670 ,pproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: $47.00 REINSPECTI • N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Special instructions: Requeste; 1 O h INSPECTION RECOI Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. -(206)431-3670 0 Approved per applicable codes. f Corrections required prior to approval. COMMENTS: /l $47.00 NSPECTION REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Special instructions: INSPECTION RECO‘ Retain a copy with permit • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206)431-3670 11 Corrections required prior to approval. COMMENTS: I spector Date: e: .00 REINSPECTION FEE EQUIRED. Prior tqlinspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to sc edule reinspection. Receipt No: Date: -Am Special instructions: Date wanted: 1 INSPECTION NO. INSPECTION RECO Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: or: 47.00 REINSPECT! at 6300 Southcenter Receipt No: N FEE REQUIRED Prior to inspection, fee must be paid lvd., Suite 100lvd., Suite 100. , all to schedule reinspection. Special instructions: Date wanted: Phone: INSPECTION RECO Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 (206)431- 3670 Approved per applicable codes. Corrections; required prior to approval. COMMENTS: Inspect 47.00 REINSPECTION EE REQUIRED. Prior ti inspection, fee must be paid at 6300 Southcenter Blv. Suite 100. Call to s• edule reinspection. Receipt No: Type of Inspection: .' Date called: Special instructions Date wanted INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. INSPECTION RECOR Retain a copy with permit' PERMIT. NO. (206)431- 3670 .. COMMENTS: . ._ Inspector: Date: Corrections required prior to approval. r El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Approved Per applicable codes. INSPECTION RECOR Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter. Blvd, #100, Tukwila, WA 98188 D©) -•o6/ )PERMIT NO. (206)431 -3670 ecial . instructions: Typ..of Inspection: Date called: ze ? / Date wanted: Requester: & r✓ Phone: Corrections required prior to approval. COMMENTS: $47.' ' INSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt NQ: Date: Date called: sa (!0.2 4 6- Special instructions: Date wanted: ` Requester: 6 Phone: INSPECTION NO. Approved per applicable codes. INSPECTION RECO Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: $47.O'O REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Special instructions: INSPECTION NO. Approved per applicable codes. INSPECTION RECOR. Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila,WA 98188 (206)431 -3670 Corrections required prior to`approval. COMMENTS $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: MAY -31 -08 SAT 12:05 PM SEATTLE CONSTRUCTION • RESOURCES INCORPORATED FAX TRANSMITTAL To: Ken Nelsen — City of Tukwila From: Steve Pitt Pam (206) 431 -3665 Pages: 3 including cover Phone: (206) 431 -3670 Date: 05/31/02 Re: Business Interiors NW—Parking Ramp CC: file 0 Urgent XFor Review D Please Comment D Please Reply 0 Please Recycle • Comments: FAX NO. 2062825210 P. 01/03 MAY.-31-08 SAT 12:05 PM SEATTLE CONSTRUCTION City of Tukwila 6300 Southcenter Boulevard Tukwila, WA 98188 -3670 Attn: Ken Nelsen Re: Permit #D02 -061. Thank you RESOURCES INCORPORATED Dear Mr. Nelsen, Please find the attached drawing with the revision to the parking lot ramp at the McConkey Business Park, 10838 East Marginal Way South. This was the design based on the meeting and conversation between our job site foreman and your field inspector. This seems to be a very practical approach and solution this situation. We appreciate your input and also your field inspector's input. If you have any questions, please feel free to contact me at (206) 71 -1011. Steve Pitt (206) 714 -1011 Seattle Construction Resources, Inc. Encl. (1) page May 31, 2002 1414 ELLIOTTAVENUE WEST • SEATTLE WA • 98119 (206)282.7500 (206) 282.5210 FAX FAX NO. 2062825210 P. 02/03 ABANDONED LOADING DOCK DOOR RAMP BELOW SYMBOL WALKWAY ON SURF DISCOURAGE VIOLATION NEW RAMP WRH 42'H CONC. SIDE WALLS AND HANDRAILS PER CODE NEW WALK AND CURB EL +0' -0' EXIST. PARKING STALLS - MODIFY TO COMPACT MODIFY DOSING IRRIGATION SYSTEM P3 REQUIRED TO CONTINUE SERVING PLANTER 11'-0' MIN. 5'-0' MIN. PARTIAL SITE PLAN DUST PLANTER AND PLANTS - RESTORE ANY PLANTS DAMAGED DURING CONSTRUCTION NOTE: AMOUNT OF 'CUT" FOR RAMP FOUNDATIONS = 17 CY; AMOUNT OF 'FILL' FOR RAMP ABANDONED LOADING DOCK DOOR 1 VAN ACCESSIBLE STALL' BELOW INTERNATIONAL SYMBOL. PER UBC 1107.3. WALKWAY STRIPES PANTED ON SURFACE TO DISCOURAGE PARKING VIOLATION SLOPE MAX VAN ACCESSIBLE STALL MIN. 5'-0' MIN. PARTIAL SITE PLAN SLOPE NEW TOP RAIL EXIST STAR, LANDING, WALLS RAILS EXIST. PLANTER AND PLANTS - RESTORE ANY PLANTS DAMAGED DURING CONSTRUCTION 4 + 4'-2' NEW RAMP WITH 42"H CONC. SIDE WALL3 AND HANDRAILS PER CODE NEW WALK AND CURB EXIST. PARKING STALLS - mookynt2«: Am? MODIFY DUSTING IRRIGATION SYSTEM AS REQUIRED TO CONTINUE SERVING PLANTER 15'-0" NOTE: AMOUNT OF "CUT' FOR RAMP FOUNDATIONS 17 CY; AMOUNT OF "FILL" FOR RAMP DOORS & WALL BEYOND EXIST. TOP PIPE HANDRAIL EXIST. STAIRS & WALL TO REMAIN (BEYOND) EXIST. GRADE Q PARKING LEVEL RAMP ELEVATION 1/8" =1' -0" NEW TOP a . PIPE RAIL EXIST. STAIRS TO BE COVERED BY NEW RAMP EXIST. CONC. WALL BEYOND NEW CONC. RAMP, HANDRAIL, GUARDRAIL & 4" CURB NEW CONC. WALL BEYOND NEW TOP RAIL - MATCH EXIST. DTL. & FINISH NEW CONC. WALL EXTENSIONS & HANDRAILS EL. +7 -2" NEW CONC. RAMP OVER 4" CRUSHED STONE OVER COMPACTED FILL EXISTING STAIR & SIDE WALLS (SHOWN POCHED FOR CLARITY) RAMP SECTION 1/4" =1 -0" NEW PIPE HANDRAILS & GUARDRAILS - 4" MAX. GAP NEW CONC. WALL W/4" CURB NEW ASPHALT PATCH EXIST. ASPHALT FINISH NOTES: - HORIZONTAL SURFACES OF RAMP TO BE LIGHT BROOM FINISHED - ALL CAST -IN -PLACE WALLS TO BE SMOOTH -FORM SURFACES RAMP SECTION EXIST. WALLS BEYOND EXIST. CONC. STAIR WALL & TOP RAIL NEW CONC. WALL EXTENSION, TOP RAIL & HANDRAIL NEW CONC. RAMP OVER 4" CRUSHED STONE OVER SOIL FILL CONC. FOOTING & ASPHALT PATCH - SEE SK-3 & SK -5 EXIST. GRADE WALL SECTION 316 Terry Avenue North, Suite A, Seattle, Washington 913109: phone 206-184-1784 fax 206-2647 Project: Designed by!. — 70 Sheet No RECEIVED CITY OF TUKWILA APR 2 4 2002 PERMIT.CFNTER 04/24/2002 12:19 2062647769 PERBIX BYKONEN/ESSER PAGE 04 WALL SECTION RECEIVED CITY OF TUKWILA APR 2 4 2002 PERMIT CENTER 316 Terry Avenue North, Suite A, Seattle, Washington 96109; phone 206-264-7784 fax 206-264-72 Project.. Designed Sheet flo,: 04/24/2002 13:57 2062647769 WALL SECTION 3/4" =1' -0" PERBIX BYKONEN /ESSER SKB ARCHITEf CITY OF UKWIL APR 2 4 2002 6 ERMIT CENTER 04/16/2002 15:10 2069031586 Apri116, 2002 RE: Permit # 1)02 -061 Revision Submittal/Installation of Accessible Ramp Mr. Ken Nelsen City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Dear Ken, Per our conversation this afternoon we are submitting the following. 1. The owner has agreed to install an accessible rump. 2. Attached you will find a drawing indicating the intent, dimensions and location of the ramp. 3. $kB will forward details of the ramp to the City of Tukwila by Wednesday, April 24, 2002 It is our understanding that by providing this information now, that a permit for interior construction will be approved and issued in the next day or two. We will put a hardcopy of this information in the mail today. Thank you for your time and consideration on this project. Kelly Van Gelder cc: Rich Lacher Steve Pitt 1403 Third Avenue #310 Seattle, WA 98101 SKB ARCHITECTS PAGE 01 RECEIVED CITY OF TUKWILA PERMIT CENTER P (206) 903•C575 F (206) 903 -1586 ABANDONED LOADING DOCK DOOR t 'VAN ACCESSIBLE STALL' BELOW INTEr1NAT1ONAL SYMBOL PER UBC 1107.3. VAN ACCESSIBLE STALL WALKWAY STRIPES PANTED ON SURFACE TO DISCOURAGE PARKING VIOLATION - 1:10 SLOPE MAX 11' -0" I MIN. 5' -0' MN. PARTIAL SITE PLAN EXIST. PLANTER UP 3D' 1:12 SLOPE EXIST STAIR, LANDING, WALLS, AND RAILS 1' -0' 30'1-0" NEW RAMP WITH 42'H CONC. SIDE WALLS AND HANDRAILS PER CODE NEW WALK AND CURB EXIST. PARING STALLS — MODIFY TO COMPACT Project Info Project Address For Bulld Departm Use Covered Parking (standard paint) Applicant Name: 13,5, N css p o -e N, rptivv Applicant Addressl/.taGt 2 6 . meccrviNtti,isAy S Applicant Phone :scene am : s#cve Pf tt 2.B 2.-160c Alteration Exceptions (check appropriate box) 0 No changes are being made to the lighting • Less than 60% of the fixtures are new, and installed lighting wattage Is not being Increased Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Covered Parking (standard paint) 2 X 4-f' ' Rcce.s e of eINtoresce40- Covered Parking (reflective paint) Open Parking Total Proposed Watts may not exceed al Allowed Watts for Interior Total Proposed Watts c 4 p 6 Location I Descriptiion/4,1 t0N Allowed Watts per i 1 or per If Area In ft (or If for perimeter) Allowed Watts x ft (or x If) Covered Parking (standard paint) Covered Parking (reflective paint) Open Parking Outdoor Areas Bldg. (by facade) Bldg. (by perim)tCP4L) Note: for building exterior, choose either the facade area ea or the perimeter method, but not both) Total Allowed Watts Number of Watts/ Watts Location Fixture Description Fixtures Fixture Proposed Total Proposed Watts may not exceed Total Allowed Walls for Exterior Total Proposed Watts CITY OF TUKWiLA Lighting Summary LTG -SUM 2001 Washington Slate Nonresidential Energy Code Compliance Farms Project Description Compliance Option Maximum Allowed Lighting Wattage (Interior) Location (floor /room no.) Occupancy Description FILE COPY Area In ft? 5 2 9. Allowed x Area 10 q • From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts I D Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. 'Proposed Lighting Wattage (Interior }ist all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank. Maximum Allowed Lighting Wattage (Exterior) Q New Building 0 Addition [Alteration 0 Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Prescriptive ( Lighting Power Allowance 0 Systems Analysis See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) 4-1 Buildin • Division se mgr listed maximum input wattage. For fixtures with hard -wired ballasts only, default table In the NREC Technical Reference Manual may also be used. DO au. Juno 2001 - KJM Lighting Summary LTG -SUM 2001 Washington Slate Nonresidential Energy Code Compliance Farms Project Description Compliance Option Maximum Allowed Lighting Wattage (Interior) Location (floor /room no.) Occupancy Description 1 . 2- FILE COPY Area In ft? 5 2 9. Allowed x Area 10 q • From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts I D Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. 'Proposed Lighting Wattage (Interior }ist all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank. Maximum Allowed Lighting Wattage (Exterior) Q New Building 0 Addition [Alteration 0 Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Prescriptive ( Lighting Power Allowance 0 Systems Analysis See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) 4-1 Buildin • Division se mgr listed maximum input wattage. For fixtures with hard -wired ballasts only, default table In the NREC Technical Reference Manual may also be used. DO au. Juno 2001 - KJM Lighting Permit Plans Checklist 2001 Washington State Nonresidential Energy Code Compliance Forms LTG -CHK June 2001 - KIM Project Address I Date The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Requires Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513 1513.1 Local control /access Schedule with type, Indicate locations 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans , overhead glazing Indicate overhead glazing on plans 1513.4 Display /exhib /special Indicate separate controls , 1513.5 Exterior shut -off Schedule with type and features, indicate location (a) timer w/backup Indicate location (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 4 1513.7 Commissioning Indicate requirements for lighting controls commissioning n. a. Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency • If "no" is circled for any question, provide explanation: ` I y �iltinu 5 i � ol 1 C5C �� �► C 1 \LAV1c r " k0 W1 b2. CITY OF TUKWILA MTBuilding Division �e �,l RECEIVED CITY OF TUKWILA MAR 12 2002 PERMIT CENTER Envelope Requirements (enter values as applicable) Fully heatedlcooled space Minimum Insulation R- values Roofs Over i■ttic Glazing Area Calculation Note: Below grade walls may be Included in the Gross Exterior Wall Area if they are insulated to the level required for opaque Total Glazing Area Electronic version: these values are automatically taken from ENV=UA -1 (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing All Other Roofs ' _ X 100 = Concrete/Masonry Option Opaque Walls Below Grade Walls Floors Over Unconditioned Space Slabs -on -Grade Radiant Floors Maximum U- factors Opaque Doors Vertical Glazing Overhead Glazing Maximum SHGC (or SC) Vertical /Overhead Glazing I Space Heat Type 0 Electric resistance 0 All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be Included in the Gross Exterior Wall Area if they are insulated to the level required for opaque Total Glazing Area Electronic version: these values are automatically taken from ENV=UA -1 (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing _ X 100 = Concrete/Masonry Option 0 yes Check here if using this option and if project meets all requirements for the Concrete /Masonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying assembly below. *-This PVbj CID S 4O T f - Mum 1' ► la vt. CITY OF TUKWILA Nt\) G I1 - 1•g. Building Division Envelope Summary Climate Zone 1 ENV -SUM 2001 Washington Stale Nonresidential Energy Code Compliance Forms First Edition. June 2001 Project Info Project Address Applicant Name: Applicant Address: Applicant Phone: Date For Building Department Use [Project Description 1 13 New Building 0 Addition Alteration 0 Change of Use Compliance Option D Prescriptive 0 Component Performance (See Decision Flowchart (over) for qualifications) ENVSTD 2.1 Systems (4.0 not acceptable) Analysis Semi- heated space Minimum Insulation R- values Roofs Over Semi- Heated Spaces 1. Assemblies with metal framing must comply with overall U- factors 2. Refer to Section 1310 for qualifications and requirements Notes: Opaque Concrete /Masonry Wall Requirements Insulation on interior - maximum U- factor is 0.19 Insulation on exterior or integral - maximum U- factor is 0.25 If project qualifies for Concrete /Masonry Option, list walls with HC Z 9.0 Btulft °F below (other walls must meet Opaque Wall requirements). Use descriptions and value from Table 20-5b in the Code Wall Description (including insulation R - value & position U- factor SV �i�'SiltA, RECEIVED CITY OF TUKWIL /' MAR "i 2 PERMIT CENTEI! Z F�- H W 6 2 00 ND J = t•— W u. WO �Q _ d F.. W Z = I- O W • I - ui U � O N o F— W w .• Z W U= O • I•- Z April 10, 2002 Kelly Van Gelder SKB Architects 1403 Third Ave. Seattle, WA 98102 city of Tukwila Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Number D02 -061 Business Interiors Northwest 10838 East Marginal Way S Dear Ms. Van Gelder: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected oh your drawings. I have enclosed comments from the Building Department. At this time, the Public Works, Planning and Fire Departments have no comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3684 Sincerely, KcLtG ,fitTtSo Kathryn A. Stetson Permit Technician encl xc: File No. D02 -061 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431 -3670 • Fax: 206 - 431 -3665 Steven M. Mullet, Mayor BUILDING DIVISION REVIEW Date: April 5, 2002 Project Name: Business Interiors Northwest building permit application Application #: D02 -061 Plan Review: Ken Nelsen, Senior Plans Examiner No further comments at this time. Tukwila Building Division 6300 SouthCenter Blvd. Tukwila, WA 98188 206 - 431 -3670 A general Building Department plan review has been completed for the subject project. Please address the following comments in an itemized format with revised plans, specification, and /or other documentation. 1. The proposed scope of work changes 4,000 square feet of warehouse area to new office space. The extent of the occupancy change will require that the building be made accessible by means of an exterior ramp or equivalent method per Washington State Building Code Amendment Sections 1101 and 1109. Provide applicable plans. 2. In addition to the building accessibility, provide accessible parking and route of travel complying with W.S.B.C. Amendment Section 1107. 3. The existing warehouse is not considered a heated space. Washington State Energy Code Section 1133 requires the new office to be isolated by insulation at a minimum heated to semi - heated condition from the warehouse. Provide revised plan details to demonstrate how the new office will be insulated per the Energy Code. u�+... «.... �.. v.. �, v w. n�o�...•. e: s` m:.» v. Vtty�Nb {w+.tlrifSPf�?F Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ® Response to Incomplete Letter # 1 [] Response to Correction Letter # (] Revision # after Permit is Issued Project Name: BUSINESS INTERIORS NORTHWEST Project Address: 10838 East Marginal Way S Contact Person: Kelly Van Gelder Summary of Revision: V1 eS City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Plan Check/Permit Number: D02 -061 , Phone Number: 2 0 6 — 9 0 3 - 0 RFJ:FIVFD CITY OF TUKWILA MAR 12 ZUUZ PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: O Entered in Sierra on 03/08/02 March 8, 2002 Kelly Van Gelder SKB Architects 1403 Third Avenue Seattle, WA 98102 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application #1 Development Permit Application Number D02 -061 Business Interiors Northwest 10838 East Marginal Way S Dear: Ms. Van Gelder: This letter is to inform you that your permit received at the City of Tukwila Permit Center on March 6, 2002, is determined to be incomplete. Before your permit application can begin the plan review process the following items need to be addressed. Building Division: Ken Nelsen, Plans Examiner, at (206)431 -3670, if you should have any questions regarding the following: 1. Provide Washington State Energy Code compliance information. Steven M. Mullet, Mayor Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206)431 -3670. Sincerely, Brenda I-folt, Permit Coordinator encl File: Permit File No. D02 -061 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 Job Number: 02 -250 Resort Number: 001 Permit Number: D02.061 Owner x Contractor Address: 10838 E Marginal Way S, Tukwila Architect x Building Dept. 9C _ Engineer Inspected the resteel and placement at Job Number: 02 -250 Resort Number: 001 Permit Number: D02.061 Test Date Project: Business Interiors NW Architect: SKB Address: 10838 E Marginal Way S, Tukwila Engineer: Perbix Bykonen Client: Seattle Construction Resources Contractor: Seattle Construction Resources Date: 5 -30 -02 Inspector: Gordy Moe / Jeff Moses Inspected the resteel and placement at Exterior stair walls monolithic reinforce per approved plan and specs. noting structural engineers SK -2, dated 4 -24 -02 Resteel is grade I 40 ) , as specified, from Cascade Mills Placement Data Batch Weights Supplier: Salmon Bay Cement jack/typellbs.): I /II 564# W/C Ratio: .49 Mix Number: 602 Fine Agg. (lbs.): 1310# Admixtures (specify) Max Slump Allowed: Coarse Agg. (size /lbs.): 7/8" — 1920# Total Yards Placed: 12 Coarse Agg. (size /lbs.): Placed Via: Pump Coarse Agg. (size /lbs.): Vibrated: Yes Fly Ash (lbs.): Specified Strength (psi): Water (lbs. /g_al): 280# Sampling and Casting of Samples ASTM C 172, C 31 Cubic Yards Slump C 143 Air % C 231 Conc. Temp C 1064 Ambient Temp Truck No. Ticket No. Cast Samples: 1-4 10 4'/z" NT 69° 55° 60 462795 Cast Samples: Compressive Cast Samples: Weather: I Cloudy Slump Range: 14 " +1 -1" Date Samples Picked Up: 15 -31 -02 Comments Specified strength was not specified. _ Other ASTM Methods Used: Specimen Number Test Date Field Cure Age (Days) Size (In.) Area (Sq.ln.) Weight Max Load (Lbs.) Strength (psi) Tested in general accordance with 1 6 -6-02 7 6x12 28.14 29.48# 140,580 5000 ASTM C 39 X ASTM C 78 ASTM C 109 Compressive X • Flexural SAMPLE TEST RESULTS: ) Conforms I Does Not Conform Cosies to: This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Form No.: T.102 Revised: 01/02 OTTu ROSENAU & ASSC INC. Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118 -3216 USA Tel: (206) 725 -4600 • Toll Free: (888) OTTO -4 -US • Fax: (206) 723,-22211 r) ;ur WBE W2F5913684 • WABO Registered Agency • A2LA Accredited Laboratory • Website: w (+' s +wkser�.uam;�rK+n,,r,fiflrA'aHr� CONCRETE REPORT REINFORCING STEEL & MIX DESIGN: I TEST RESULTS Reviewed by: Page 1 of 1 Conforms I x) Does Not Conform ‘01 Job Number: I 02 -250 Owner x Contractor Architect: SKB Architect x Building Dept. a Contractor. Seattle Construction Resources Engineer Inspector: Gordy Moe /Jeff Moses 1 Job Number: I 02 -250 Report Number: I • 001 I Permit Number: I •D02 -061. Field Cure Project: Business Interiors NW Architect: SKB Address: 10838 E Marginal Way S, Tukwila Engineer: Perbix Bykonen Client: Seattle Construction Resources a Contractor. Seattle Construction Resources Date: 5 -30 -02 Inspector: Gordy Moe /Jeff Moses 1 Inspected the resteel and placement at Exterior stair walls monolithic reinforce per approved plan and specs. noting structural engineers SK -2, dated 4 -24 -02 7 Resteel is grade I 40 I , as specified, from Cascade Mills Placement Data Batch Weights Su • • lier: Salmon Ba Cement sack/t •e/lbs. • I /11 564# W/C Ratio: .49 Mix Number. 602 Fine Agg. (lbs.): 1310# Admixtures (specify) Max Slum • Allowed: Coarse A... size/lbs. : 7/8" — 1920# 28.24 Total Yards Placed: 12 Coarse Agg. (size /lbs.): Coarse Agg. (size /lbs.): 6170 Placed Via: Pump Vibrated: Yes Fly Ash (lbs.): 6 -27 -02 Specified Strength (psi): Not specified Water (lbs./gal): 280# 6x12 Sampling and Casting of Samples ASTM C 172, C 31 Cubic Yards Slump C 143 Air % C 231 Conc. Temp C 1064 Ambient Temp Truck No. Ticket No. Cast Samples: 1-4 10 4 1 /2" NT 69° 55° 60 462795 Cast Samples: ' Cast Samples: X Weather: I Cloudy Slump Range: I 4 " +1 -1" Date Samples Picked Up: ( 5 -31 -02 Comments Other ASTM Methods Used: I Specimen Number Test Date Field Cure Age (Days) Size (In.) Area (Sq.In.) Weight Max Load (Lbs.) Strength (psi) Tested in general accordance with 1 6 -6 -02 7 6x12 28.14 29.48# 140,580 5000 ASTM C 39 X 2 6 -27 -02 28 6x12 28.24 29.63# 174,120 6170 ASTM C 78 3 6 -27 -02 28 6x12 28.24 29.52# 171,600 6080 ASTM C 109 4* Compressive X Flexural SAMPLE TEST RESULTS: I Conforms I Does Not Conform *Discarded Copies to: OTTu ROSENAU $ ASS01ATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118 -3216 USA Tel: (206) 725 -4600 • Toll Free: (888) OTTO -4-US • Fax: (206) 723 - 2221 WBE W2F5913684 • WABO Registered Agency • A2LA Accredited Laboratory • Website: www.ottorosenau.com CONCRETE REPORT REINFORCING STEEL & MIX DESIGN: TEST RESULTS Reviewed by: Conforms Does Not Conform I This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Form No.: T -102 Revised: 01/02 'i n�if +�Ji,'.r`i• " " j.;;: , '.r:5;':Y�1j v; ;<ij Y*i :• .,,, e. .,..:rEti�.`.a:Y Page 1 of 1 Z ~ • W 0 U U W _ WO LL. U � a I— ILI Z � 1— O Z I— W W U 0 O N O H W I— LL. - 13 W Z U 0 H O Z ACTIVITY NUMBER: D02 - 061 PROJECT NAME: Business Interiors NW SITE ADDRESS: 10838 East Marginal Way S Original Plan Submittal Response to Correction Letter # DATE: 04 -24 -02 Response to Incomplete Letter # X Revision # J After Permit Is Issued DEPA TR MENTS: Bu n , Division 425.67. Public Works �'k MA) e 5 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES /THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: Approved Notation: Documents/routing slip.doc 2.2802 PLAN REVIEW /ROUTING SLIP Fire P 4 • 2 Structural • Incomplete Structural Review Required Approved with Conditions n PERMIT COORD COPY Planning Division 4.2 'e Permit oordinator DUE DATE: 04-5-02 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 05-23-02 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z w QQ 2 J U O 0 • o Uj J W O g J � � d = w z � z� Lu U� O N O H al H O .. w • = O ~ z Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: _ 2 --. D 2. 0 Response to Incomplete Letter # Response to Correction Letter # 4 Revision # L after Permit is Issued Project Name: City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Plan Check/Permit Number: D02 -061 Business Interiors Northwest Project Address: 10838 East Marginal Way S Contact Person:. '. V t N d n CDI l . lS - Phone Number: 206 — q 0 3- 057.5 Summary of Revision: der telte* off' infeh4. daf 1 4-16-61 drawings straw accessibk ramp (eix f ev7'or). St-ttiS 114 PAC (/AC (k -1 — S k --1) [X Entered in Sierra on `T ~ ''a t t — o . REGISTERED ARCI IITECT BRIAN COLLINS-FRIEDRICHS STATE OF WASHINGTON Sheet Number(s): (4( mot d v111 , in-Fvvwi a-h'o v) "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: RECEIVED CITY OF TUKWILA APR 2 % 2002 PERMIT CENTER 04/10/02 z z r w -J O 0 • o J • u_ W O u . D. 0 w F- _ z �. I 0 - ui U O 0— O F- Ww I U = 0 z • ACTIVITY NUMBER: D02 - 061 PROJECT NAME: Business Interiors NW DATE: 04 - 24 - 02 SITE ADDRESS: 10838 East Marginal Way S Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # I . After Permit Is Issued DEPARTMENTS: Building Division Public Works PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2.28.02 �•cxumromr Incomplete n (C.'Gt,-%_, PI n Planning Division Permit Coordinator n DUE DATE: 04 -5-02 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route n Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 05 -23-02 Approved with Conditions Not Approved (attach comments) [1 DATE: ZS' Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z w -J U O CO C J = f w 0O �J u. ¢ = � w z = 1- H O z I- tu U O N O I— w • w • O to .• Z w O z 1 ACTIVITY NUMBER: D02 -061 PROJECT NAME: Business Interiors NW SITE ADDRESS: 10838 East Marginal Way S DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route n Structural Review Required I I No further Review ' equired REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Notation: Documents/routing slip.doc 2.28.02 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # j After Permit Is Issued n PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete n n J3 DUE DATE: 04-25-02 Not Applicable n DATE: DATE: 04 -24 -02 Planning Division Permit Coordinator DUE DATE: 05-23-02 n Approved with Conditions n Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Building Division Public Works Complete n Approved L_ i Notation: n n PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 - 061 PROJECT NAME: Business Interiors NW DATE: 04 - 24 - 02 SITE ADDRESS: 10838 East Marginal Way S Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # x, Revision # I After Permit Is Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: Cr\ APPROVALS OR CORRECTIONS: Approved with Conditions n n Planning Division Permit Coordinator DUE DATE: 04-5-02 Not Applicable No further Review Required DATE: 11 /2-- -- /D 1-- Not Approved (attach comments) I�1 n n DUE DATE: 05- 23-02 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip,doc 2.28 -02 } . ;ASrt **2=t100801 AV w re JU U O N o J F =— w 0 _ w Z = 1— O Z 1— W W O O H w W • 0 u. O .. z U= O ~ z !1 ACTIVITY NUMBER: D02 - 061 PROJECT NAME: Business Interiors NW SITE ADDRESS: 10838 East Marginal Way S DATE: 04 -24 -02 Original Plan Submittal Response to Incomplete Letter # Response to. Correction Letter # Revision # 1 After Permit Is Issued DEPARTMENTS: Building Division Public Works Complete Comments: Documents/routing slip,doc 2.28 -02 n PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: S REVIEWER'S INITIALS: I!1 Fire Prevention Structural Incomplete n n is?et" n n Planning Division Permit Coordinator n n DUE DATE: 04-25-02 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: APPROVALS OR CORRECTIONS: ID ?z ,,,,,,,; F - DUE DATE: 05-23 -02 I 6J Approved ► . tlApproved with Conditions Not Approved (attach comments) n Notation: '' ND PIA) fCYIVi f ES p G-J17 £ U s 2 V i oW* I DATE: 5 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: gar.rs:n'fKi2 zi^; , • ;#514„(. k'jp'19(y ACTIVITY NUMBER: D02 - 061 PROJECT NAME: Business Interiors Northwest SITE ADDRESS: 10838 East Marginal Wy S DATE: 04 -10 -02 Original Plan Submittal Response to Incomplete Letter # x Response to Correction Letter # 1 Revision # After Permit Is Issued DEPARTMENTS: Ll Public Works Complete Comments: DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS ROUTING: Documenls/rouling slip.doc 2.28.02 Approved Ti Notation: a Please Route reStructural Review Required APPROVALS OR CORRECTIONS: PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete E 0 Planning Division n Permit Coordinator Not Applicable n DUE DATE: 04-11-02 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required REVIEWER'S INITIALS: DATE: Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY DUE DATE: 05-09 -02 n z ~ U 00 co o J H U L w O � = • d � Z = H Z I— LL! • W n O - o W O .. W co O~ z ACTIVITY NUMBER: D02 - 061 PROJECT NAME: Business Interiors Northwest SITE ADDRESS: 10838 East Marginal Wy S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # / Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: n APPROVALS OR CORRECTIONS: Fire Prevention Structural Incomplete n Approved ❑ Approved with Conditions Notation: 6e REVIEWER'S INITIALS: Documents /rousing slip.doc 2- 28-02 PLAN REVIEW /ROUTING SLIP 1)v' 2< PI n DATE: 04 -10 -02 Planning Division Permit Coordinator n DUE DATE: 04-11-02 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Please Route JL Structura Review Required n No further Review Re uired n REVIEWER'S INITIALS: - DATE: DUE DATE: 05 -09-02 No Approved (attach comments) saf 0 itez4 uk� DATE: 1b Cra._ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: t•: z I ~ w O 0 (/) 0 LLI J H w0 u. = d �.w z = I— I— 0 z I— W • W O • p_ 0 w W • O .. Z U= O I—' z PERMIT NO.:DN"aI 1 BUILDING PERMITS INSPECTIONS ❑ 1 Progress Inspection Status ❑ 2 Pre- construction ❑ 3 Investigation ❑ 4 OK to Occupy ❑ 5 Remove Stop Work Order ❑ 6 Follow -up ❑ 7 Pre -Move Inspection ❑ 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ 70 NLEA Inspection /Iviodular Struct ❑ 71 Mobile Home Tie Down Insp ❑ 72 Marriage Lines ❑ 90 Resteel ❑ 95 Footing Drains ❑ 100 Foundation Footings ❑ 200 Foundation Walls ❑ 250 Foundation Insulation ❑ 300 Concrete Slab /Slab Insulation ❑ 350 Crawl Space ❑ 400 Shear Wall Nailing ❑ 450 Plywood Wall Sheathing ❑ 500 Roof Sheathing Nailing ❑ 525 Plywood Deck Nailing ❑ 550 Exterior Wall Sheathing ❑ 600 Masonry Chimney ❑ 610 Chimney Installation/All Types 00 Framing 750 Roof/Ceiling Insulation ❑ 800 Floor Insulation 501 Wall Insulation ❑ 802 Exterior Roof Insulation 803 Glazing Inspection 815 Lighting and Controls 900 Suspended Ceiling 1000 Interior Wallboard Fastening ❑ 1001 Exterior Wallboard Fastening ❑ 1110 Pre -Move Inspection ❑ 1 1 15 Motor Inspection ❑ 1120 Pre -Demo ❑ 1140 Pre- reroof ❑ , 1400 Final -Fire 1700 Final- Building ❑ 1900 Final - Reroof ❑ 3100 Site Visit ❑ 4000 Special - Concrete ❑ 4001 Special -Bolts in Concrete ❑ 4001 Special - Mom/Resist Conc Frame ❑ 4003 Special -Reinf Steel Prestress ❑ 4004 Special - Welding ❑ 4005 Special- High - Strength Bolting ❑ 4006 Special- Structural Masonry ❑ 4007 Special -Reinf Gypsum Concrete ❑ 4008 Special - Insulating Conc Fill ❑ 4009 Special -Spray Fireproofing ❑ 4010 Special - Piling, Piers, Caissons ❑ 4011 Special - Shotcrete ❑ 40 P Special- Grading, Excav /Fill ❑ 4013 Special- Retaining Wall ❑ 4014 Special - Panels ❑ 4015 Special -Smoke Control System TENANT NAMESJ6 l v oe5S -F-VI T`eX i c* - ,'�J \ki CONDITIONS 1000 No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & t 10004 All mechanical work shall be under separate permit 10005 All permits, insp records & approved plans available 10006 All structural concrete shall be special inspected ❑ 10007 All structural welding shall be done by WABO certified inspector ❑ 10008 All high- strength bolting shall be special inspected ❑ 10009 Bolts installed in concrete shall be special inspected 10010 When special inspection is required...notify Tukwila T Building Division 10011 The special inspector shall submit a final signed report ❑ 10012 Any new ceiling grid and light fixture installation ❑ 10013 Partition walls attached to ceiling grid ❑ 10014 Readily accessible access to roof mounted equipment ❑ 10015 Engineered truss drawings & calcs shall be on site ❑ 10016 Any exposed insulation backing material shall have ❑ 10017 Subgrade preparation including drainage, excavation ❑ 10018 A statement from the rooting contractor verifying tire retardant class of roof 10019 All construction to be done in conformance w /approved plans r ❑ 10020 Structural observation shall be provided for this project ❑ 10021 All food preparation establishments must have King Co ❑ 10022 Fire retardant treated wood shall have flame spread of ❑ 10023 Notify Building Division prior to placing any concrete ❑ 10024 All spray applied fireproofing shall be special inspected ❑ 10025 All wood to remain in placed concrete shall be treated ❑ 10026 All structural masonry shall be special inspected 10027 Validity of Permit ❑ 10028 Rack storage requires separate permit 10030 No occupancy of building until final insp by Bldg Div ] 10031 Comply with requirements of TIM 16.04 ❑ 10032 Remove all weeds, concrete, stone foundations, flat concrete ❑ 10034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ 10035 Contact PW Div to obtain insp for water /sewer connect ❑ 10036 Manufacturers installation instructions required on site ❑ 10038 A C of 0 will be required for this permit ❑ 10039 Final approval for all TI w /in the limits of the SC Mall ❑ 10040 All construction noise to be in compliance with 8.2 TMC ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate ❑ 10044 Water heater shall be anchored ❑ 10045.........Reroof ❑ "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" Plan Reviewer: Permit Tech: • Date: Date: 6Z \ Complete ACTIVITY NUMBER: D02 -061 DATE: 03 -26 -02 PROJECT NAME: Business Interiors Northwest SITE ADDRESS: 10838 East Marginal Way S Original Plan Submittal x Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: n �� �VYI i n g . b l ivrio Building Divisio Ate 3 - Ic or�Cs DETERMINATION OF COMPLETENESS: (Tues., Thurs.) • APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ri n PERMIT COORD COPY Planning Division ri Permit Coordinator sd DUE DATE: 03-28-02 Not Applicable Ti Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required Ti REVIEWER'S INITIALS: DATE: DUE DATE: 04 -25-02 Approved Ti Approved with Conditions Ti Not Approved (attach comments) Ti Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z • 1 ~ W -JU O 0 U) J � L w O g Q = • a I— w Z = I O Z I— W • W U � O - o 1 . w w I • U = O F- z DEPARTMENTS: Building Division Public Works Complete Notation: Documents/routing slip.doc 2-28-02 TUES /THURS ROUTING: REVIEWER'S INITIALS: REVIEWER'S INITIALS: Please Route I Vl Structural Revie APPROVALS OR CORRECTIONS: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 - 061 DATE: 03 -26 -02 PROJECT NAME: Business Interiors Northwest SITE ADDRESS: 10838 East Marginal Way S Original Plan Submittal X Response to Incomplete Letter # t Response to Correction Letter # Revision # After Permit Is Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Approved n Approved with Conditions eArtY n Planning Division Permit Coordinator Not Applicable n DUE DATE: 03-28-02 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: eq red n No further Review Required n DATE: 3 -2L' a Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 04-25-02 Not Approved (attach cornments) j DATE: !.� (s.-(crz_ DEPARTMENTS: Building Division Public Works Complete n Documents/routing slip.doc 2.28 -02 n PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -061 DATE: 03 -26 -02 PROJECT NAME: Business Interiors Northwest SITE ADDRESS: 10838 East Marginal Way S Original Plan Submittal 4. Response to Incomplete Letter # I Response to Correction Letter # Revision # After Permit Is Issued Fire Prevention L14. Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n TUES /THURS ROUTING: Please Route 1/r Structural Review Required APPROVALS OR CORRECTIONS: Approved ri Approved with Conditions n Notation: 1)0 P 4 A- ekiJI f ►eS REVIEWER'S INITIALS: j S Planning Division U Permit Coordinator DUE DATE: 03-28-02 Not Applicable n n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: - � �„ 1 �, s r sL�'k ;,,6x' ,G .p,04 ,II �: � � n No further Review Required n REVIEWER'S INITIALS: DATE: DUE DATE: 04 -25 -02 Not Approved (attach comments) n DATE: 3/ 21/0 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z ~ w a aa 2 JU 00 co 0 • liJ J F- U)w wO Q . to � E z � I— 0 z H U O S2 � H w I— I- U. — 0 ..z w U O H z ot* 0014 tJERMIT COORD CC. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -061 DATE: 3 -06 -02 PROJECT NAME: BUSINESS INTERIORS NORTHWEST SITE ADDRESS: 10838 EAST MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Bui dibg'Di ision [7� � . .p?.� Pu orks Fire,�Prbvention [� Structural 36 ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Incomplete Planning ivision [/]� 3.7•oZ X Perm it coordinator DUE DATE: 3-07 -02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 01,' Departments determined incomplete: Bldg Er Fire 0 Ping ❑ PW ❑ Staff Initial APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2.213.02 PERMIT COORD COT'S( DUE DATE: 4 -04 -02 DATE: z Z 6 JU O 0 J 1- W O • }} g J � 2 I- W Z H I- O Z W U� 0 1- W W • 0 F. u' .. z W U= O ~ Z 4� ACTIVITY NUMBER: D02 -061 DATE: 3 -06 -02 PROJECT NAME: BUSINESS INTERIORS NORTHWEST SITE ADDRESS: 10838 EAST MARGINAL WAY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: re 0 APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28.02 Fire Prevention Structural PLAN REVIEW /ROUTING SLIP Incomplete REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 3-07-02 ❑ Not Applicable ❑ t, h cC E yv tl t vvx g, Permit. Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route ❑ Structura eview Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: S / DUE DATE: 4 -04 -02 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z Iz 6 00 U, J H w0 g �Q N� =a 1-W z 1- O Z F- w • w U � O � O H W • W LI O ..z W O - O H-. Z ACTIVITY NUMBER: D02 -061 DATE: 3 -06 -02 PROJECT NAME: BUSINESS INTERIORS NORTHWEST SITE ADDRESS: 10838 EAST MARGINAL WAY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 PLAN REVIEW/ROUTING SLIP Incomplete ❑ Fire Prevention Structural Planning Division Permit Coordinator DUE DATE: 3 -07-02 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete:. Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 4-04-02 Not Approved (attach comments) ❑ Notation: DATE: 3 //r7.---- Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ■ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -061 DATE: 3 -06 -02 PROJECT NAME: BUSINESS INTERIORS NORTHWEST SITE ADDRESS: 10838 EAST MARGINAL WAY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division ❑ Fire Prevention ❑ Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete APPROVALS OR CORRECTIONS: Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: 1 DUE DATE: 3 -07 -02 DATE: Not Applicable ❑ DUE DATE: 4 -04 -02 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28.02 z w JU 00 N J u. WO g Q N C! = W ' Z F.. HO Z I— W W U � O 0 I— W 1 W Z U= O~ z 4 ACTIVITY NUMBER: D02 -061 DATE: 3 -06 -02 PROJECT NAME: BUSINESS INTERIORS NORTHWEST SITE ADDRESS: 10838 EAST MARGINAL WAY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DEPARTMENTS: Building Division Public Works Complete ❑ D�( DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS ROUTING: Please Route Yi Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: Ltr}•y1/\ APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2.213.02 PLAN REVIEW /ROUTING SUP Incomplete REVIEWER'S INITIALS: Revision # After Permit Is Issued Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator ❑ DUE DATE: 3-07-02 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DATE: Not Applicable ❑ DUE DATE: 4 -04 -02 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Revision 1 No. 1 Date ' I Received 1 Staff Initials Date i Staff Issued 1 Initials I 1 1 Summary of Revision: Summary of Revision: Received By: Received By: .. Revision No. . 1 Date Received Staff Initials Date I Issued ! Staff I Initials I I Summary of Revision: Received By: Received By: Revision No. Date Received Staff Initials Date Issued Staff 1 Initials ._. Summary of Revision: Received By: Revision No. Date Received Staff 1 Date I Staff Initials 1 - Issued i Initials 4 1 I . Summary of Revision: Received By: PROJECT NAME: 8U5/kieSS ivevfCrIorS PERMI" JO:. Oa1 Site Address: 1 bg38 E • rvlarct Wy Original Issue Date: REVISION LOG Revision Date Staff Date No. Received Initials Issued I Summary of Revision: act ett K A Oki ctccestbl ra.titp. nr.. (.1 . ,0 0,1, • .• • •.. Received By: 6- r E_ fl (please prim) (please print) (please prim) (please print) (please print Staff Initials , •.t. •% 41 z i I- L AJ 0 • 0 U) coal W I -J 1.- U) u_ w 0 u. co uj z I- z uj • 0 O ▪ D- o I— w r c.) O I— z 1/2 Fire Department Project Name I ? (,� /A1E >4, lr' /, • /id • Address I (' L ) S Suite # Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: /, Permits: Authorized Signature FINALAPP.FRM TUKWILA FIRE DEPARTMENT FINAL APPROVAL, FORM Permit No. T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief C(/ Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575%4404 • Fax (206) 575-4439 EXPIRATION DATE 12 -31 -2002 DATE ISSUED 03/01/2002 LICENSE NUMBER 02 -1382 FEE PAID $50.00 SALES TAX CODE No. 1729 e• e4g-ta- CITY CLERK City of Tukwila, Washington RUMNESS _JCENSE 282 -7500 General Contractor TELEPHONE NATURE OF BUSINESS LICENSEE AGREES TO COMPLY WITH ALL THE REQUIREMENTS OF CITY ORDI- NANCES AND STATE LAWS APPLICABLE TO THE BUSINESS ACTIVITY LICENSED HEREUNDER. Seattle Construction Resrc. 1414 Elliott Ave W Seattle WA 98119 -3124 This license Is to be displayed conspicuously at the location of business and is not transferable or assignable. REGISTERED ` AS;';PROVIDED CONST 'CONT. GENERAL GZSTs: 'avl:,' EX FEAT' !LE .CONST RESOURCE '�Ir r2:414 ELLYOTT' , AVE.W SEATTLE 'W • —. 98119 Detach And Display Certificate ready for issuance BUSINESS INTERIORS NORTHWEST 10838 East Marginal Way, S. Tukwila, WA 98168 ! understand that te Plan Check cipro als are erlOIS an c sad approval of piens does not a:;.,.o the , .ola n o any ! aopfe c coe or �r ^inarc�. ,Ript of can- iracors c ope of approve p lans ece ac!�nos�ledged. SEPARATE i'ER IT REQUIRED FOR: IFS ELECTRICAL [✓I PLUMBit:G E GAS PIPING CITY OF TUKWILA BUILDING D!V!SION RECEIVED CITY OF TUKW ILA MAR 0 6 2002 PERMIT CENTER COVER SHEET VICINITY MAP GENERAL NOTES 1. DO NOT SCALE DRAWINGS. 2. IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT ALL WORK COMPLY WINE WASHINGTON STATE BUILDING CODE, THE WASHINGTON STATE ENERGY CODE, AND OTHER APPLICABLE CODES, RULES AND REGULATIONS OF JURISDICTIONS HAVING AUTHORITY 3. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPENCIES NOTED AMONG OR BETWEEN THE CONTRACT DOCUMENTS, OWNER - PROVIDED INFORMATION, SITE CONDITIONS, MANUF- ACTURER RECOMMENDATIONS, OR CODE REGULATIONS, OR RULES OF JURISDICTIONS HAVING AUTHORITY. 4. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE CONTRACT DOCUMENTS, OWNER PROVIDED INFORMATION AND SITE CONDITIONS, INCLUDING TAKING F:ELD MEASUREMENTS AS NECCESSARY. 5. THE CONTRACTOR SHALL PAY AND SECURE AND ALL GOVERNMENTAL PERMITS, FEES, LICENCES, AND INSPECTION NECCESSARY FOR PROPER EXECUTION AND COMPLETION OF THE WORK EXCEPT FOR THE GENERAL BUILDING PERMIT 6. ALL DIMENSIONS ARE TO FACE OF FINISH. UNLESS OTHERWISE NOTED. CONTACT ARCHITECT FOR CLARIFICATIONS IF NEEDED. SYMBOL LEGEND COLUMN GRID LINE DETAIL WALL SECTION BUILDING SECTION/ELEVATION DATUM REVISION NORTH INTERIOR ELEVATION REFERENCE ROOM IDENTIFICATION OT'ENING NUMBER WALL/PARTITION TYPE a - DETAIL NUMBER (OR LETTER) -- -- DRAWING NUMBER ROOM NAME 0001> ROOM NUMBER S:CTION NUMBER (OR LETTER) DRAWING NUMBER -- SECTION DESIGNATION (OP LETTER) -- DRAWING NUMBER SEE TITLE BLOCK FOR REVISION. MOST RECENT REVISION SHOWN CLOUDED. D0� - 0(0 "ACCESS I STRIES" VERTIC • , MODEL TG 50. SEE . SHEET. "VAN ACCESSIBLE STALL" BELOW INTERNATIONAL SYMBOL PER UBC 1107.3. ( r1 k,( ' O PARTIAL SITE PLAN WALKWAY STRIPES PANTED ON SURFACE TO DISCOURAGE PARKAS VIOLATION VAN ACCESSIBLE STALL 11," MIN. PXIST /NC, ()NW STORY -- OFFCE AND WAREHOUSE CD PLOT PLAN 1" = 40' -0" EXIST. PLANTER STALLS Ex /ST /Nf 4 - HE AREA SEPARATION VOWEL PROJECT INFORMATION PROJECT ADDRESS: PROJECT DESCRIPTION: TAX PARCEL NUMBER: 032 - 304 -9164 DCLU PROJECT NUMBER: BLDG. CODE INFORMATION 1. THE BUILDING IS DESIGNED IN COMPLIANCE WITH THE FOLLOWING CODES AND REGULATIONS: A 1997 SEATTLE BUILDING CODE WHICH IS AN AMENDED VERSION OF THE 1997 EDITION OF THE UNIFORM BUILDING CODE. 2. THE BUILDING IS DESIGNED IN COMPLIANCE WITH THE FOLLOWING REQUIREMENTS: A. OCCUPANCY TYPE: GROUP B OCCUPANT LOAD CALCULATIONS: OFFICE: STORAGE: CONFERENCE. OCCUPANT LOAD = 137.87 OCC. 2 EXITS REQUIRED, 2 EXITS PROVIDED B. BUILDING SQ. FT.: 92,515 SF D. OCCUPANCY SEPARATION B (OFFICE) TO S-2 (WAREHOUSE) NONE REQUIRED E. CONSTRUCTION TYPE III -N F. FIRE PROTECTION: FULLY SPRINKLERED G. NO ALTERATIONS TO BUILDING ENVELOPE XIS1Tit`IGI ONE S T)KI oFFAG tAs] 10838 EAST MARGINAL WAY, S. TUKWILA, WA 98168 TENANT IMPROVEMENTS TO 8,524SF OF EXISTING SPACE 7,270 SF / 100 = 72.7 OCC. 291 SF /300 = .97 OCC. 963 SF / 15 = 64.2 OCC. 4Sr MARG//1/AL WAY SOUTH (HWY, 5 -1u) ARCHITECTURAL DRAWING INDEX COVER SHEET A0.1 PROJECT INFORMATION A1.1 DEMOLITION PLAN A2.1 FLOOR PLAN A3.1 REFLECTED CEILING PLAN A4.1 POWER /DATA PLAN A9.1 DOOR SCHEDULESELEVATIONEFINISH SCHEDULES A9.2 PARTITION TYPES4NTERIOR DETAILS PROJECT DIRECTORY TENANT: ARCHITECT: BUSINESS INTERIORS NORTHWEST 10838 EAST MARGINAL WAY, S. TUKWILA, WA 98168 (206) SKB ARCHITECTS 1403 THIRD AVENUE #310 SEATTLE, WA 98101 CONTACT: KELLY VAN GELDER 206.903.0575 GENERAL CONTRACTOR: SEATTLE CONSTRUCTION 1414 ELLIOTT AVENUE, W. SEATTLE, WA 98119 CONTACT: STEVE PITT 206 -282 -7500 LEGAL DESCRIPTION KING COUNTY ASSESSOR'S #032 -304 -9164 BEGINNING AT THE POINT IN THE EASTERLY MARGIN OF EAST MARGINAL WAY AND THE SOUTH LINE OF SECTION 3, TOWNSHIP 23 NORTH RANGE 4 EAST, W.M. IN KING COUNTY WASHINGTON , SAID POINT OF BEING 61t792 FEET, MORE OF LESS EASTERLY OF THE SOUTHWEST CORNER OF SAID SECTION, THENCE SOUTH 88° 47 20" EAST ALONG SAID SECTION LINE 324.785, MORE OF LESS, TO THE WESTERLY BOUNDARY LINE OF PUGET SOUND POWER AND LIGHT COMPANY RIGHT OF WAY, FORMERLY SEATTLE TACOMA INTERURBAN RAILWAY RIGHT OF WAY, THENCE FOLLOWING SAID WESTERLY BOUNDARY ON AN ARC OF A CURVE TO THE LEFT POINT HAVING A RADIUS OF 2514.93 FEET AND THE LONG CHORD OF WHICH BEARS NORTH 18 °15'00' WEST 359.985 TO A POINT OF TANGENCY: THENCE CONTINUING ALONG SAID BOUNDARY NORTH 21 °5350" WEST 53350 FEET TO A POINT ON A CURVE: THENCE ALONG SAID BOUNDARY ON THE ARC OF A CURVE TO THE RIGHT HAVING A RADIUS OF 2914.93 FEET AND THE LONG CHORD OF WHICH BEARS NORTH 16 °25 53" WEST TO THE NORTH MARGIN TO PLACE OF BEGINNING: EXCEPT THAT POR - ION DESCRIBED AS FOLLOWS: COMMENCING AT A POINT OF THE EASTERLY BOUNDARY LINE OF EAST MARGINAL WAY, SAID POINT BEARS NORTH 16 °4730" WEST 138793 FEET FROM THE POINT WHERE THE SAID BOUNDARY LINE INTERSECTS THE SOUTH BOUNDARY LINE OF SAID SECTION 3: RUNNING THENCE SOUTH 16 °4730' EAST ALONG SAID EAST MARGINAL LINE 192.529 FEET: THENCE 50U11189 ° 37 30" EAST 232.103 FEET TO A POINT 70 FEET DISTANT FROM THE CENTER LINE OF SEATTLE TACOMA INTERURBAN RAILWAY :THENCE ON THE ARC OF A CURVE HAVING A RADIUS OF 2934.93 FEET ALONG THE WEST BOUNDARY LINE OF A CERTAIN LINT AND PARALLEL TO SAID CENTER LINE, THE LONG CORD OF WHICH ARC DEARS NORTH 13 °24'13" WEST 159.402 FEET: THENCE NORTH 59°3730" WEST ALONG THE SOUTH BOUNDARY LINE OF A CERTAIN PRIVATE ROAD 243.819 FEET TO THE PLACE OF BEGINNING. CORRECTION LTR# RECEIVES CITY R OF TUKWILA PERMIT CENTER DEMO. EXIST. WALL - FOR NEW DOOR TO WAREHOUSE SEE A2.01 O DEMOLITION PLAN REMOVE & RELOCATE REFRIGERATOR PER A2.01 REMOVE SHOWER & BENCH - SEE A2.1 FOR NEW FIXTURE LOCATIONS SERVER LOCATION TO REMAIN PREPARE EXISTING PLUMBING FOR ADDITIONAL FIXTURES PER A2.01 SALVAGE DOORS TO BE REUSED PER A2.01 DASHED LINE INDICATES EXISTING ELEMENT TO BE DEMOLISHED EXIST. EXIT DOOR DIRECT TO EXTERIOR TO REMAIN WAREHOUSE FIXTURES TO BE RELOCATED PRIOR TO DEMOLI1TON CONCRETE CURB TO BE REMOVED & PATCHED DEMO. WALL FOR NEW RELITE TO MATCH EXIST. SEE A2.01 NOTES: 1. REMOVE ALL ACT CLNG. & TRACK 2. DASHED UNE INDICATES ITEMS TO BE DEMOLISHED. II \ 11 II I 1 \\ ii EXIST. EXIT DOOR III DIRECT TO EXTERIOR TO REMAIN RECEIVED CITY OF TUKWILA MAR 0 6 200? PERMIT DEMOLITION PLAN A1.1 OPEN OFFICE EXIST. DOCK LEVELER - ADD SUBFLOOR, FLOAT TO MATCH EXISTING FLOOR GWB FURRING OVER EXIST OVERHEAD DOORS 122 CLOSET CLOSET STORAGE 11220 CONFERENCE O PARTIAL FLOOR PLAN `- 2 PAIR SLIDING I WOOD DOORS CL ROOM W/GLASS LITES ELEC. CL. UPPER & LOW CABINETS COFFEE COPY/ PRIPSTE -R OFFICE' CONF. RM. 1 119 RECEPTION EXISTING ELECTRICAL PANEL TO REMAIN 6" CLR. PE CHED. TACK PANEL 6" CLR. EQ. REUSE EXISTING DOORS RR 2 WHENEVER POSSIBLE, TYP. _ - - - - -- WAITING 7 OPENING EXISTING EXIT DOOR I DIRECT TO EXTERIOR I TAP INTO EXISTING PLUMBING WALL FOR T NEW FIXTURE CONNECTIONS, FIXT. TO MATCH EXIST. DO a- ° to EXISTING STAIRS TO GRADE 55' 0 1 /2 " OPEN OFFICE 1 109 I NEW RECITE TO MATCH EXIST. 0 NOTES: 1. U.O.N. PARTITION IS TYPE 1. C7 2_ FE.C. THIS SYMBOL INDICATES WALL - MOUNTED FIRE EXTINGUISHER CABINET. OFFICE 1 108 I OFFICE EXIT 2 EXISTING EXIT DOOR �. DIRECT TO EXTERIOR FLOOR PLAN A2.1 reflected ceiling plan a3.1 OPEN OFFICE STORAGE 0 POWER & DATA PLAN CONFERENCE a4.1 ELEC, CL. 122DI COPY/ PRINTER OFFICE/ CONE RM. SERVER I 120 I RECEPTION WAITING r 152 NOTES 1. PROVIDE MOTION DETECTORS IN COPY/PRINTER ROOM. ® ( OPEN OFFICE I 109 LEGEND QUADPLEX q i DUPLEX VOICEDATA 7 VOICE CLNG. DROP J OFFICE 102 OFFICE 1107 CORP. RM. RECEIVED CITY OF Tiikwir, MAR 0 S 2(02 FINISH SCHEDULE DOOR TYPE ELEVATIONS N T S. MARK SIZE 03 3' -0" X 7' -0' - A3 MATCH EXIST. MATCH EXIST. 107 3' -0" X 7' -0" - A2 MATCH EXIST. MATCH EXIST. 1 08 3' -0" X 0 -0' - A2 MATCH EXIST. MATCH EXIST. '09 (2) 3' -0" X 7' -0" - Al MATCH EXIST MATCH EXIST 3' -0" X 7' -0` - Al MATCH EXIST. MATCH EXIST "13 0-0 XX7-0 -_. _ -.. -. - A' MATCH EXIST MATCH EXIST X T -0" - A3 MACH EXIST MATCH EXIST '20 3' -0" X 7' -0" - Al WOOD WOOD 21 -' (2) 3•-0 X 7' -0" - A4 MATCH EXIS MATCH EXIST. Al 1 21 - 3' -0" X 7 -0 - '22 , (2) 3' -0" X 7' -0" - - 122A (2) 3' - X T-0" - 122B (2) 3' -0' X 7' -0" - 1220 1 (2) 3' -0' X 7 -0" - 122C-2 (2) 3' -0' X 7-0" - 122 -D 3' -0" X 7' -0" - SOLD CORE DOOR WITH FINISH 'O MATCH EXISTI DOOR SCHEDULE RATING DOOR DOOR FRAME TYPE MATERIAL MATERIAL A3 MATCH EXIST MATCH EXIST MATCH EXIST . MATCH EXIST. , MATCH EXIST.', MATCH EXIST. MATCH EXIST MATCH EXIST. MATCH EXIST MATCH EXIST. MATCH EXIST. MATCH EXIST. MATCH EXIST. MATCH EXIST. TO .4ATCH EXIST. q 41, EQ., I A2 T OFFICE CLOSET CLOSET STILE AND RAIL DOOR FINISHED TO MATCH EXISTING W /12" TEMPERED GLASS LITE AND DETACHED RE -LITE TO MATCH EXISTING SILL JAMB HEAD HDWR REMARKS DETAIL DETAIL DETAIL GROUP CONFERENCE ROOM OFFICE ENTRY TO WAREHOUSE RESTROOM RESTROOM OFFICE/CONFERENCE ROOM ILSERVER ROOM TRAINING ROOM TRAINING ROOM ENTRY TO WAREHOUSE STORAGE CLOSET STORAGE CLOSET ELECTRICAL CLOSET A3 HARDWARE GROUP HARDWARE GROUP HARDWARE GROUP 3 WIRE GLASS RATED DOOR FINISH TO MATCH EXISTING FRAMES 1/8" TEMPERED GLASS LITE 3 EA BUTTS DOS -06 I PASSAGE 1900 US26D 4 1/2 X 4 12 EA. LATCHSET CL3310 AZD 626 SA114 EA. FLOORWALL STOP I.. 1270CVCP /1211 626 3 EA. SILENCERS 3 I EA. BUTTS EA. LOCKSET 1 EA. FLOORWALL STOP 1270CVCP /1211 626 3 EA. SILENCERS EA. BUTTS EA. LOCKSET EA. SILENCERS OFFICE (NOT USED) NO. 2 1900 US260 4 12 X 4 1/2 CL3351 AZD 626 SA114 STORE RM. CL3357 AZD 626 SA114 EA. FLOORWALL STOP 1270CVCP /1211 626 HARDWARE SCHEDULE NO.1 NO. 1900 US26D 4 1/2 X 4 1/2 HARDWARE GROUP A4 5 EA. BUTTS 1 EN. ELECTRIC HINGE CL3310 AZD 626 SA114 1 EA. LOCKSET 1 ' EA. ELECTRIC LOCK 01520 -CL3357 24VDC 1 SET CONSTANT LATCHING FLUSH BOLTS 20 FT. GASKET I S44D HARDWARE GROUP EA. PIVOT PULL 1 ROLLER LATCH SLIDING GLASS FIRE RATED 1270CVCP /1211 626 945 US26D 1 EA. DUSTPROOF STRIKE 80 US26D 1I EA. COORDINATOR 672 X (2 EA.) 601AB USP 2 EA. WALL/FLOOR STOP 1270CVCP /1211 626 CLOSET WIRE 1559 X 1559B 626 1 OVERHEAD STOP ' 10 -346 630 NO. 4 1900 US26D 4 1/2 X 4 1 /2 NO. 5 RIXSON MODEL 117:117 626 HARDWARE GROUP 3 EA. BUTTS 3 EA. SILENCERS 1 EA. FLOORWALL STOP 1270CVCP /1211 626 CARD READ LOCKSET COORDINATE VV/OWNER HARDWARE GROUP 3 3 EA. SILENCERS CARD READ LOCKSET @ STAIR -SIDE RETROFIT ALL STAIRWELL DOORS COORDINATE W'OWNER DATA CLOSET EA. FLOORWALL STOP 1270CVCP /1211 626 NO. 6 1900 US26D 4 12 X 4 1/2 NO. 7 EA. BUTTS 1900 US26D 4 12 X 412 GENERAL NOTES I. REFER TO SHEET A9.1 FOR ALL REFERENCED DETAILS. 2. ALL DOORS TO BE LOCATED 6" OFF ADJACENT PARTITIONS, U.O.N. 3. ALL DOOR HARDWARE TO COMPLY WITH ADA GUIDELINES. 4. PAINTED FRAMES ARE TO BE SEMI -GLOSS FINISH. 5. REFER TO PROJECT MANUAL FOR HARDWARE GROUP SPECIFICATIONS. S. AT SOUND GASKETED DOOR, SET FRAME IN EXPANDABLE FOAM SEALANT. ``'J INDICATES V4" TEMPERED GLASS. RECEIVED CITY OF TUKWIL4ZZ MAR 0 n 26021= DOOR SCHEDULE ELEVATIONS / FINISH SCHEDULE A9.1 FINISH SCHEDULE DOOR TYPE ELEVATIONS N T S. MARK SIZE 03 3' -0" X 7' -0' - A3 MATCH EXIST. MATCH EXIST. 107 3' -0" X 7' -0" - A2 MATCH EXIST. MATCH EXIST. 1 08 3' -0" X 0 -0' - A2 MATCH EXIST. MATCH EXIST. '09 (2) 3' -0" X 7' -0" - Al MATCH EXIST MATCH EXIST 3' -0" X 7' -0` - Al MATCH EXIST. MATCH EXIST "13 0-0 XX7-0 -_. _ -.. -. - A' MATCH EXIST MATCH EXIST X T -0" - A3 MACH EXIST MATCH EXIST '20 3' -0" X 7' -0" - Al WOOD WOOD 21 -' (2) 3•-0 X 7' -0" - A4 MATCH EXIS MATCH EXIST. Al 1 21 - 3' -0" X 7 -0 - '22 , (2) 3' -0" X 7' -0" - - 122A (2) 3' - X T-0" - 122B (2) 3' -0' X 7' -0" - 1220 1 (2) 3' -0' X 7 -0" - 122C-2 (2) 3' -0' X 7-0" - 122 -D 3' -0" X 7' -0" - SOLD CORE DOOR WITH FINISH 'O MATCH EXISTI DOOR SCHEDULE RATING DOOR DOOR FRAME TYPE MATERIAL MATERIAL A3 MATCH EXIST MATCH EXIST MATCH EXIST . MATCH EXIST. , MATCH EXIST.', MATCH EXIST. MATCH EXIST MATCH EXIST. MATCH EXIST MATCH EXIST. MATCH EXIST. MATCH EXIST. MATCH EXIST. MATCH EXIST. TO .4ATCH EXIST. q 41, EQ., OFFICE CLOSET CLOSET STILE AND RAIL DOOR FINISHED TO MATCH EXISTING W /12" TEMPERED GLASS LITE AND DETACHED RE -LITE TO MATCH EXISTING SILL JAMB HEAD HDWR REMARKS DETAIL DETAIL DETAIL GROUP CONFERENCE ROOM OFFICE ENTRY TO WAREHOUSE RESTROOM RESTROOM OFFICE/CONFERENCE ROOM ILSERVER ROOM TRAINING ROOM TRAINING ROOM ENTRY TO WAREHOUSE STORAGE CLOSET STORAGE CLOSET ELECTRICAL CLOSET A3 HARDWARE GROUP HARDWARE GROUP HARDWARE GROUP 3 WIRE GLASS RATED DOOR FINISH TO MATCH EXISTING FRAMES 1/8" TEMPERED GLASS LITE 3 EA BUTTS DOS -06 I PASSAGE 1900 US26D 4 1/2 X 4 12 EA. LATCHSET CL3310 AZD 626 SA114 EA. FLOORWALL STOP I.. 1270CVCP /1211 626 3 EA. SILENCERS 3 I EA. BUTTS EA. LOCKSET 1 EA. FLOORWALL STOP 1270CVCP /1211 626 3 EA. SILENCERS EA. BUTTS EA. LOCKSET EA. SILENCERS OFFICE (NOT USED) NO. 2 1900 US260 4 12 X 4 1/2 CL3351 AZD 626 SA114 STORE RM. CL3357 AZD 626 SA114 EA. FLOORWALL STOP 1270CVCP /1211 626 HARDWARE SCHEDULE NO.1 NO. 1900 US26D 4 1/2 X 4 1/2 HARDWARE GROUP A4 5 EA. BUTTS 1 EN. ELECTRIC HINGE CL3310 AZD 626 SA114 1 EA. LOCKSET 1 ' EA. ELECTRIC LOCK 01520 -CL3357 24VDC 1 SET CONSTANT LATCHING FLUSH BOLTS 20 FT. GASKET I S44D HARDWARE GROUP EA. PIVOT PULL 1 ROLLER LATCH SLIDING GLASS FIRE RATED 1270CVCP /1211 626 945 US26D 1 EA. DUSTPROOF STRIKE 80 US26D 1I EA. COORDINATOR 672 X (2 EA.) 601AB USP 2 EA. WALL/FLOOR STOP 1270CVCP /1211 626 CLOSET WIRE 1559 X 1559B 626 1 OVERHEAD STOP ' 10 -346 630 NO. 4 1900 US26D 4 1/2 X 4 1 /2 NO. 5 RIXSON MODEL 117:117 626 HARDWARE GROUP 3 EA. BUTTS 3 EA. SILENCERS 1 EA. FLOORWALL STOP 1270CVCP /1211 626 CARD READ LOCKSET COORDINATE VV/OWNER HARDWARE GROUP 3 3 EA. SILENCERS CARD READ LOCKSET @ STAIR -SIDE RETROFIT ALL STAIRWELL DOORS COORDINATE W'OWNER DATA CLOSET EA. FLOORWALL STOP 1270CVCP /1211 626 NO. 6 1900 US26D 4 12 X 4 1/2 NO. 7 EA. BUTTS 1900 US26D 4 12 X 412 GENERAL NOTES I. REFER TO SHEET A9.1 FOR ALL REFERENCED DETAILS. 2. ALL DOORS TO BE LOCATED 6" OFF ADJACENT PARTITIONS, U.O.N. 3. ALL DOOR HARDWARE TO COMPLY WITH ADA GUIDELINES. 4. PAINTED FRAMES ARE TO BE SEMI -GLOSS FINISH. 5. REFER TO PROJECT MANUAL FOR HARDWARE GROUP SPECIFICATIONS. S. AT SOUND GASKETED DOOR, SET FRAME IN EXPANDABLE FOAM SEALANT. ``'J INDICATES V4" TEMPERED GLASS. RECEIVED CITY OF TUKWIL4ZZ MAR 0 n 26021= PER;::. 07.'TEP DOOR SCHEDULE ELEVATIONS / FINISH SCHEDULE A9.1 PARTITION (NON 'O TYPE 1 CE LING) PLAN Gwe METAL STUDS - - SOUND INSULATION AS INDICATED PARTITION TYPE (PARTIAL HT. PARTITION TYPE ( FURRING) R -11 BATi INSUL. METAL S'U'DS CONC. SURFACE PARTITION TYPE <4 (SHAFT WALL, 1 HOUR) I ' - GWB - PLAN _ GWB METAL STUDS PLAN ' EXISTING WALL � ' � GWB METAL STUDS STJD 512E STUD GAUGE MATERIAL SOE 1 MATERIAL SIDE 2 MATERIAL -- - - -- - ERE RATING. STC RATING 2 12 20 (1; '`AVER 5B" GWB _ - (1) LAYER SS" GWB - - NR 45 - - STUD SIZE. 352" I ? STUD SIZE 3 58 STUD SIZE: 2 V2" , STUD GAUGE 25 STUD GAUGE: 20 STUD GAUGE: 20 SOUND INSULATION AS INDICATED __- - UNDERSIDE OF CEILING SIDE MATERIAL: -_- -- -- SIDE 2 VATERIAL (1) :AYER 52" GWB .-- _.__...- _ —_- (1) LAYER 55 GWB SECTION GWB OR WD.. SEE DETAILS SIDE 1 MATERIAL: (1) LAYER S9" GWB CEILING METAL STUDS R BATT INSUL. SIDE 1 MATERIAL 1" GWB PLAN SIDE 2 MATERIAL — : SIDE 2 MATERIAL: SC GWB SECTION ATTACH TO — CEIUNG FIRE RATING N R FIRE RATING: NR _� SECTION TIRE RATING: . 1 HR. -11 GWB EXISTING CONC . WALL SURFACE GWB SOUND NSULATIT AS INDICATED STC RATING GWB G STC RATING: NR l - STC RATING: NA HEIGHT DIOp,TED INTERIOR ELEVATIONS ON FIRE , ES7: uec a3e: ts.t i (t HouRI N S. — VERTICAL WIRE HANGER -NO. 12 GAUGE @ 4' - 0" 0 C. OR NO. 10 GAUGE @ 5' -0" O.C. ALONG EACH MAIN RUNNER. HEAVY GAUGE WIRE "PIN ". VERTICAL STRUT @ 12' -S EACH DIRECTION FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE, HELD IN PLACE BY VERTICAL WIRE HANGER AND HEAVY GAUGE WIRE PIN. —MAIN RUNNER AT 4' -0` C.C. CROSS RUNNER ® ACT CEILING SEISMIC BRACING HEAD TO STRUCT ABOVE N.T.S. BASE 3 � PARTITION ATTACHMENT FASTEN TO EXISTING STRUCTURE OR NEW BLOCKING GWB TIGHT TO EXISTING FRAMING *SOUND ATTENUATION BLANKETS IN STUD CAVITY ACT CEIUNG OR DROPPED GWB SOFFIT GWB METAL STUD * SOUND ATTENUATION BLANKETS IN STUD CAVITY GWB POWER FASTENER AT 24" O.C. WITH 100 # PULLOUT MIN. *RUNNER SET WITH FOAM TAPE AND SEALANT * ACOUSTIC SEALANT AT PERIMETER AND AT ALL PENETRATIONS FINISH FLOOR *MODIFICATION FOR ACOUSTICALLY INSULATED WALL ONLY EXISTING STRUCTURE POWDER DRIVEN FASTENER - SIZE 8 TYPE AS REQ'D FOR SUBSTRATE - MIN. i00# PULL OUT �V — GIST. SUSPENDED ACT CEILING - BRACE DIAGONALLY TO STRUCTURE- - 25 GA. C-BRACE AS REQUIRED 3" 20 GA. TOP RUNNER, OP. SEE FLOOR PLAN FOR PARTITION TYPE ® PARTITION @ ACT. CEILING ON SUBSTRATE ® CLOSED BASE CAB. 1 1/2" =1' -0" RB 4" SPLASH TO MATCH COUNTER —PLAM ON 3/4" SUBSTRATE (WRAP NOSE), V4" PLYWOOD BACK BRACKET HOLES AT 2" O.C. VERTICALLY 3'4" PLYWOOD SHELVES WEDGE BAND ALL INTERIOR SURFACES TO BE ALMOND MELAMINE ON SUBSTRATE PARTITION SCHEDULE NO SCALE N.T.S. 2 -0' MAX. TO FIRST fl' -0' MAX. SUPPORT BRACE BETWEEN BRACING SUPPORT BRACING AT PARTIAL HEIGHT PARTITION U.O.N. ' ADA SINK CABINET 1 1/2" =1' -0" — 20 GA. MTL STUD @ SUPPORT BRACE - 2"x2"',V5 "x24' LONG ANGLE - WELD TO BASE PLATE - FASTEN TO STUD WITH (3) #6 SCREWS 2 . 1 5(6,161 PLATE- FASTEN TO CONCRETE WITH 232 DA. BOLTS FULL HEIGHT PARTITION PART AL HEIGHT PARTITION - - - - - SUPPORT BRACE, TP 4` SPLA OUNTESH R TO MATCH C PLAM ON 3 SUBSTRATE (WRAP NOSE), REFER TO INT. ELEVATIONS ADA COMPLIANT SINK PROVIDE BLACK, WASTE PIPE GUARD LINE OF ADA REQUIRED CLEARANCE - - -PLAM ON SUBSTRATE REFER TO INT ELEVATIONS PAINTED SHT. MET., SCREW TO B.O. DOOR, COLOR TO MATCH ADJASCENT BASE U.O.N. GENERAL NOTES I. OETAL STUDS SPACING TO BE 24" O.C. UNLESS OTHERWISE NOTED. 2 PARTITION TYPES ARE ASSUMED TO END AT INTERSECTING WALLS. WHERE RATED PARTITIONS INTERSECT NON - RATED PARTITIONS THE RATED PARTITION IS ASSUMED TO CONTINUE UNINTERRUPTED. 3. SEE INTERIOR ELEVATIONS FOR WALL HEIGHTS KEY < ___ PARTRON TYPE X 1 1/2" =1'-0" a _______-- INDICATES ACCOUSTICAL BAIT INSULATION —PLANT EDGE BANDING, TYP. AT ALL EXPOSED EDGES PLAIN SHELVES PLANT ON SUBSTRATE PLAM ON 1/4" PLYWOOD BACK BRACKET HOLES AT 2" O.C VERTICALLY PLAM SIDES AND BOTTOM VALANCE AT UNDER CABINET LIGHT FIXTURE. MATCH CABINET FINISH O CLOSED UPPER CABINET DO1-OG I RECEIVED CITY OF TUKWILA MAR 0 6 2002 PERM T_ . PARTITION TYPES I DETAILS A9.2