Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D02-066 - HEATHERWOOD APARTMENTS - BUILDING E
Heatherwood Apt. "E" 5861 S 152 St D 02 -0066 Parcel No.: 1157200380 Address: 5861 S 152 ST TUKW Suite No: Value of Construction: Type of Fire Protection: Type of Construction: Public Works Activities: doc: Devperm $25,159.00 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Tenant: Name: HEATHERWOOD APARTMENTS - BLDG E Address: 5861 S 152 ST, TUKWILA, W Owner: Name: HEATHERWOOD ASSOCIATES Address: ATTN: MANAGER, 5861 S 152ND ST #F101 Contact Person: Name: SCOTT BORKIN Address: 11728 AURORA AVE N, STE 4 Contractor: Name: AARDVARK CONST INC Address: 117 NORTHPARK AVE N, SEATTLE WA Contractor License No: AARDVC1997L7 DEVELOPMENT PERMIT Permit Number: D02 -066 Issue Date: 03/18/2002 Permit Expires On: 09/14/2002 Phone: (206)248 -3926 Phone: 206 - 391 -5074 Phone: 206- 361 -8246 DESCRIPTION OF WORK: REMOVE SHEETROCK, ALL INSULATION. REHANG SHEETROCK. THREE UNITS: 103, 203, 303. D02 -066 Expiration Date: 06/26/2002 Fees Collected: $666.73 Uniform Building Code Edition: 1997 Occupancy per UBC: 0001 Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N Water Meter: Channelization / Striping: ** Continued Next Page ** Printed: 03 -18 -2002 z � z W QQ • � J U O 0 N c CO ILI W I - 1.- U) W O 2 QQ g to = I— to Z � I— O Z F 11J Lu U � O cn O I— LL uj I . L I O W Z = . OH Z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: a -.✓ 14 1 hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe it does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructi . r or the perf ance of work. I am authorized to sign and obtain this development permit. Signature: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D02 -066 Balance Due: $ Need Current Contractor Registration Card: 0 Yes Need to Enter Contractor Information in Sierra: 0 Yes scott berkin DEPARTMENTS: Building Division Public Works Complete t' Comments: ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: W APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 ?Asti PLEASE Fire Prevention Incomplete n n n n PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 - 066 PROJECT NAME: Heatherwood Apts. Bldg E SITE ADDRESS: 5861 S 152 St K b Original Plan Submittal DATE: 03 -13 -02 Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued Planning Division Permit Coordinator Not Applicable No further Review Required DATE: ?)— 1 . Q 2, n DUE DATE: 03-14-02 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DATE: DUE DATE: 04-11-02 Approved Approved with Conditions Not Approved (attach comments) ri Notation: REVIEWER'S INITIALS: IA) E Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z w U WI- ,.0 0 u. _ w a = W I- z �.. I- z I— w • w U 0 O N O 1- w w O Z N H � . O z �1 PERMITNO.: b©)- ©(o to BUILDING PERMITS INSPECTIONS ❑ 1 Progress Inspection Status ❑ 2 Pre - construction O 3 Investigation 8 4 OK to Occupy 5 Remove Stop Work Order ❑ 6 Follow -up ❑ 7 Pre -Move Inspection ❑ 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC O 70 NLEA Inspection/Modular Struct 8 71 Mobile Home Tie Down Insp 72 Marriage Lines ❑ 90 Resteel ❑ 95 Footing Drains ❑ 100 Foundation Footings ❑ 200 Foundation Walls ❑ 250 Foundation Insulation ❑ 300 Concrete Slab /Slab Insulation ❑ 350 Crawl Space ❑ 400 Shear Wall Nailing ❑ 450 Plywood Wall Sheathing ❑ 500 Roof Sheathing Nailing ❑ 525 Plywood Deck Nailing ❑ 550 Exterior Wall Sheathing ❑ 600 Masonry Chimney ❑ 610 Chimney Installation/All Types ❑ 700 Framing ❑ 750 Roof/Ceiling Insulation 800 Floor Insulation 801 WallInsulation 802 Exterior Roof Insulation ❑ 803 Glazing Inspection ❑ 815 Lighting and Controls ❑ 900 Suspended Ceiling r' 1000 Interior Wallboard Fastening 8 1001 Exterior Wallboard Fastening 1110 Pre -Move Inspection 9 1115 Motor Inspection 1120 Pre -Demo ❑ 1140 Pre -reroof ❑ 1400 Final -Fire a 1700 Final - Building 0 1900 Final - Reroof R 3100 Site Visit 4000 Special- Concrete O 4001 Special -Bolts in Concrete ❑ 4001 Special - Mom/Resist Conc Frame ❑ 4003 Special -Reinf Steel Prestress ❑ 4004 Special- Welding ❑ 4005 Special- High - Strength Bolting ❑ 4006 Special - Structural Masonry ❑ 4007 Special -Reinf Gypsum Concrete ❑ 4008 Special- Insulating Conc Fill ❑ 4009 Special -Spray Fireproofing ❑ 4010 Special - Piling, Piers, Caissons ❑ 4011 Special - Shotcrete ❑ 4012 Special- Grading, Excav /Fill ❑ 4013 Special- Retaining Wall ❑ 4014 Special- Panels ❑ 4015 Special -Smoke Control System TENANT NAME: 4f0- ertt)O0 j Ap +s . r\rke .L ■ CONDITIONS 13" 10001 No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division ❑ 10002 Plumbing permits shall be obtained through King Co ❑ 10003 Electrical permits obtained through L & I ❑ 10004 All mechanical work shall be under separate permit 10005 All permits, insp records & approved plans available 10006 All structural concrete shall be special inspected ❑ 10007 All structural welding shall be done by WABO certified inspector ❑ 10008 All high - strength bolting shall be special inspected 10009 Bolts installed in concrete shall be special inspected 10010 When special inspection is required... notify Tukwila Building Division 10011 The special inspector shall submit a final signed report 10012 Any new ceiling grid and light fixture installation 10013 Partition walls attached to ceiling grid 10014 Readily accessible access to roof mounted equipment 10015 Engineered truss drawings & calcs shall be on site 10016 Any exposed insulation backing material shall have 10017 Subgrade preparation including drainage, excavation 10018 A statement from the roofing contractor verifying fire , �a� ( retardant class of roof '1 10019 All construction to be done in conformance w /approved plans 0 0 0 0 ❑ 10020 Structural observation shall be provided for this project ❑ 10021 All food preparation establishments must have King Co ❑ 10022 Fire retardant treated wood shall have flame spread of ❑ 10023 Notify Building Division prior to placing any concrete ❑ 10024 All spray applied fireproofing shall be special inspected ❑ 10025 All wood to remain in placed concrete shall be treated ❑ 10026 All structural masonry shall be special inspected E l s 10027 Validity of Permit 10028 Rack storage requires separate permit P; 10030 No occupancy of building until final insp by Bldg Div 10031 Comply with requirements of TMC 16.04 ❑ 10032 Remove all weeds, concrete, stone foundations, flat concrete ❑ 10034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ 10035 Contact PW Div to obtain insp for water /sewer connect ❑ 10036 Manufacturers installation instructions required on site ❑ 10038 A C of 0 will be required for this permit ❑ 10039 Final approval for all TI w /in the limits of the SC Mall ❑ 10040 All construction noise to be in compliance with 8.2 TMC ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 10042........Fuel burning appliances ❑ 10043........Appliances. which generate ❑ 10044 Water heater shall be anchored ❑ 10045 Reroof ❑ "Anchoring - All new construct and substantial improvement shall be anchored to prevent flotation" Plan Reviewer: (A) E Date: a \ L, - 0 2 Permit Tech: Date: Y g A.. ,•�M +•t,r.•:tr .qtr "+'*s."te;Cttt'F.4:�� +n+�, ACTIVITY NUMBER: D02 -066 DATE: 03 -13 -02 PROJECT NAME: Heatherwood Apts. Bldg E SITE ADDRESS: 5861 S 152 St It Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: RUB PINAW Building Division n Fire Prevention Public Works n Structural n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents /routing slip.doc 2.28.02 PLAN REVIEW /ROUTING SLIP Incomplete n Planning Division Permit Coordinator DUE DATE: 03 -14-02 Not Applicable n 1 1 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route n Structural Review Required No further Review Required A. DATE: "Atk102._ DUE DATE: 04-11-02 Approved Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: City State/ Zip: Value of Construction,. c,.7-."- /., Tax Parcel Number: Site Address (include suite number) Property Owner: Will there be rack storage? ❑ yes ❑ no Existing fire protection features: ❑ sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) • Phone: Street Address: City State/Zip: Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Peron: Street Address: City State /Zip: Fax #: Description of work to be done (please t e specific): Existing use: ❑ Retail ❑ Restaurant ❑ Multi - family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family .> ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Building Square Feet: existing No. of Stories: Area of construction (sq ft): Will there be a change of use? ❑ yes ❑ no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes ❑ no Existing fire protection features: ❑ sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Will there be storage of flammable/combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets 11/30/00 clperniil. doc CITY OF TUYWILA Permit Center 6300 Southcenter f3lvc1., Suite 100 Tukwila, WA 98188 (206) 431 -3670 Date application accepted: J13-02 Date applica • expires: - , 3 Project Number: Permit Numbef 0 2 .' (0 Ik =' Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Flood Control Zone ❑ Hauling ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Applica takeny: (initials) PLEASE SIGN BACK OF APPLICATION FORM BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print name Address City /State /Zip APPLICATI S MUST BE SUBMITTED WITH TLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER 5' ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, Z identify by size and species which are to be removed and saved H W 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use IY only) S 11. Location and gross floor area of existing structure with dimensions and setback U O 12. Lowest finished floor elevation (if in flood control zone) to C] 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). u) t— _ ❑ CI Floor plan: show location of tenant space with proposed use of each room labeled to u- W ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of Q any hazardous materials; dimensions of proposed tenant space. ce Q ❑ ❑ Vicinity Map showing location of site = d I -w ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack ? 1.- layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of Z O rack. Structural calculations are required for rack storage eight feet and over. MI ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished U CI ❑ ❑ Construction details 0 H ulw ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water H H supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed tL O Z sprinkler system design criteria as identified by the Fire Department. w w U = O~ z ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11 /J/1/0I1 crpermU.dloc fM.raln +Mw+evoure .»n.s.m'.w..,yreo +.4+revxwux/e..- a +bm <+.u.o- -e..m. w.w. 1ww. w+x;+unrPdW. LICENSE DETAIL INFORMATION Form yam Page 1 of 1 STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License AARDVCI997L7 Name AARDVARK CONST INC Address 117 NORTHPARK AVE N Address City SEATTLE State WA Zip 98133 Phone Number 2063618246 Effective Date 6/27/01 Expiration Date Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code GENERAL Other Specialties UBI Number 602130449 *VIEW CROSS REFERENCE FILE FOR THIS LICENSE* * * *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * *VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * VIEW CONTRACTOR INSURANCE INFORMATION * * New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page https : / /wws2.wa.gov /lni /bbip /TF2Form .asp ?License= AARDVCI997L7 OO4,&, CIT RECEIVED MAR 1 3 2002 PERMIT CENTER 03/13/2002 Type of Inspection: Date called: Special instructions: Date wanted: Approved per applicable codes. INSPECTION RECOR Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: r $47.00 REINSPECTION Egli REQUIRED. Prior to inspection, fee must be paid 4/000 Southcenter Blvd., uite 100. CaII to schedule reinspection. Rtceipt No: Date: Type of Inspection: Address: Date called: Special instructions: Date wanted: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: INSPECTION RECORE Retain a copy with permit (206)431 -3670 Corrections required prior to approval. Date: j .r •.y Ei $47.00 REINSPECTIO FEE REQ IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Type of nspec dress: Date cal led Special instructions: 3 cd. dank Date wanted,. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 COMMENTS: $4 7.00 REINSPECTION FEE RE UIRED. Prio�f inspection, fee must be paid a t 6300 Southcenter Blvd., Sui 100. Call t94schedule reinspection. Receipt No: Date: .2/4- Date: Approved per applicable codes. Corrections required prior to approval. INSPECTION RECORD Retain a copy with permit DOCQ(o (206)431 -3670 Type of Insption: Date called: sib Special instructions: Date wanted Requester INSPECTION RECORu Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila WA 98188 Approved per applicable codes. PERMIT NO. (206)431 -367 Corrections required prior to approval. COMMENTS: 4(5 Date: $47.00 REINSPECT! N FEE REQUIRE . Prior to inspection, fee must be paid at 6300 SoUthcenter Blvd., Suite 100 Call to schedule reinspection. Receipt No: doc: Conditions City of 1 ukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1157200380 Permit Number: D02 -066 Address: 5861 S 152 ST TUKW Status: ISSUED Suite No: Applied Date: 03/13/2002 Tenant: HEATHERWOOD APARTMENTS - BLDG E Issue Date: 03/18/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 6: There shall be no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building Inspector. 7: Comply with the requirements of TMC 16.04, Demolition /Relocation of Structures and Article 87 of the Uniform Fire Code. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this per 't does not presume to give authority to violate or cancel the provision of any other work or local laws regulating constructio ►r the performance of work. \ �_ ' \� Signature: � �' Date: Print Name: PERMIT CONDITIONS D02 -066 Printed: 03 -18 -2002 .1. At ,,,.... z Z 2111 6 00 ul J H Nu_ w LL. = I— U- Z = H 0 w ~ • w U O - o 1 w .. z 0 H O z ACTIVITY NUMBER: D02 - 066 PROJECT NAME: Heatherwood Apts. Bldg E SITE ADDRESS: 5861 S 152 St X Original Plan Submittal Response to Correction Letter # Revision # DATE: 03 -13 -02 Response to Incomplete Letter # After Permit Is Issued DEPARTMENTS: Buildin Di on Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2.28.02 PER 1: RD COPY PLAN REVIEW /ROUTING SLIP V1 Structural Review Required Approved with Conditions Fire Prevention /le a- .14 Structural PERMIT c,J3Rp COPY Planning Division Permit Coordinator X DUE DATE: 03-14-02 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 04 -11 -02 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z , ~ w re O 0 rn J H U) Li. w ga � • a = w ~_ z � 1- O z w • w U to o1- w w H r- — O .. z W U 2 O F- z e replaced to match in kind. We will replace the light and the closet sliding doors. to repaint new rock to match in kind. en . liallus2m. The door will be replaced and also the heater vent light fan. The room will be wiped down and cleaned. Then the walls will be sealed and painted to match. And to replace the vinyl on the floor to match in kind plus seal the subfloor. plying rpm. The north and east wall will have the rock and insulation removed. Then the rest of the walls will be wiped down and cleaned. This will include to dry the area out with fans, heaters and-or dehumidifiers. Then new insulation will be installed and the rock will be hung and finished to match. We will seal all the left over smoked rock. Then we will spot prime and paint to match. The carpet and padding will be replaced to match. Dininac room. We will wipe down and clean the walls and ceiling. Then we will seal the walls and ceiling. The carpet will be replaced to match in kind. Then we will paint to match in kind. 'Otitis and kitchen chasm. We will wipe down and clean the walls, cabinets and ceiling. Then we will seal the walls and ceiling. Then we will paint to match in kind. RECEIVED CITY OF TUKWILA For work in 203. MAR 13 2002 l'oom1 To remove all the sheet rock in the bedroom then to replace all the insulation th$3k CENTER damaged. This will included to dry the area out with fans, heaters and -or dehumidifiers. Then to rehang the sheetrock and finish to match. Then to spot prime all the new rock. We will also seal all the exposed wood that has fire or water damage. Mildicide will be sprayed where necessary in areas affected by water. The carpet will be pulled and cleaned. Also the padding for the carpet will be replaced to prevent any mold. Then we will spot prune and paint the repaired walls to match BIOME We will remove the vinyl floor and replace in kind. Plus included sealing the floor. To remove all the sheet rock then to replace all the insulation that was damaged. This will included to dry the area out with fans, heaters and -or dehumidifiers. Then to rehang the sheetrock and finish to match. Then to spot prime all the new rock. We will also seal all the exposed wood that has fire or water damage. The carpet will be pulled and cleaned. Also the padding for the carpet will be replaced to prevent any mold. Then we will spot prime and paint the repaired walls to match. Living mow To remove all the sheet rock on the north and east walls and a section of the ceiling then to replace All the insulation that was damaged. This will included to dry the area out with fans, heaters and -or dehumidifiers. Then to rehang the sheetrock and finish to match. Then to spot prime all the new rock. We will also seal all the exposed wood that has fire or water damage. The carpet will be pulled and cleaned. Also the padding for the carpet will be replaced to prevent any mold. Then we will spot prime and paint the repaired walls to match. YsSLS !ea*; nn.n.7nv..,,, r.. ,, ., -.... _Y_sr�iaaia'sz . , — Doa-.0(9 Payee: ACCOUNT ITEM LIST: doc: Receipt City of Tukwila Current Pmts 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 z RECEIPT , 1t-: Parcel No.: 1157200380 Permit Number: D02 -066 Address: 5861 S 152 ST TUKW Status: APPROVED 0 0 Suite No: Applied Date: 03/13/2002 w w Wm Applicant: HEATHERWOOD APARTMENTS - BLDG E Issue Date: -- co LL •w O Receipt No.: R020000373 Payment Amount: 405.85 g 5 Initials: SKS Payment Date: 03/18/2002 01:29 PM = d User ID: 1165 Balance: $0.00 H _ TRANSACTION LIST: O — Type Method Description UJuj Amount I U AARDVARK CONSTRUCTION INC Payment Check 1286 405.85 • Z Description Account Code BUILDING - RES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 Printed: 03 -18 -2002 TRANSACTION LIST: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 1157200380 Permit Number: D02 -066 Address: 5801 S 152 ST TUKW Status: PENDING Suite No: Applied Date: 03/13/2002 Applicant: HEATHERWOOD BLDG E Issue Date: Receipt No.: R020000345 Payment Amount: 260.88 Initials: KAS Payment Date: 03/13/2002 03:12 PM User ID: 1684 Balance: $405.85 Payee: AARDVARK CONSTRUCTION .Amount Type Method Description Payment Check 1274 260.88 ACCOUNT ITEM LIST: Current Pmts PLAN CHECK - RES Description Account Code 000/345.830 260.88 Total: 260.88 03/14 -,)71s.; TOD.AIL 260 Printed: 03 -13 -2002 OPAQUE .70 2E5,5TANCE WALLS ‘2417 , 5/.0 A/2 W00D 5 /P /A/6 BLDG FAFE unit a floor plan VALUES ROOF FRAMING PLAn I understand that the Plan Check approvals are subject to errors and omissions and approval PPro of plan; does not auhonzz ; ^e v' ,i;;n of , ;y adopted code or ordnance. Recelot of tractor's copy of a p / plans acknowledged. By Date Permit No. DDZ-064, GAS PIPING CITY OF TUKWILA BUILDING DIVISION Ks COMA! D02 -066 RECEIVED OITY OF TUKWIL. MAR 3 7002 PERMIT CENTER SILL specifications NOTES Desi soil bearing value 2.000 P-S.P All footings ,est r,nt 0., unaiste earth, or roripaetad fill Owner shall supply ce,srate r-i,f,rcinc steel Subsoitractor shel I au; a I I for - ,,I s tien, anchor 'bolto anc accassorted ro County Inn ., Subcontractor shall 7 Fnendetion, shall 70 1/0" 8 Nib nn Grad, a. Comolete fine ii .1 b. Place 4 Hill Poly,Laylan, 000r ,,,jrr c. Place reinforcia nteel footia d7 ,hall be deformed bars confc,idni, to A-515 grad, "D 0. Place 6"x6" - 10/10 2,37 are, e. Pour slab with a ,iinimum of 5 sc., -ement per cubic yard of concrete mux f. Place 1/2". 10" anchor bolts at - 0" on center and 12' from each corner or end of sill plate Slab area shall be steel troweled and level within 1/8" 9. Concrete shall be free of voids and rock pockets, subcontractor shall grout and sack any voids immediately after removing for 10. Immediately after removing forms, subcontractor must verify finish grade elevation of slab and if any difference found, must proceed to correct it immediately prior commencing framing lay-out- 11. Glue a rigid insulation (Min. P.= ) to the entire perimeter of the foundation prior to backfilline. 12. All work performed shall 'conform with U.B.C. and approved by the 13ne County Building ins7ector. 13. It is the subcontractors responsibilitly to study the 51009 and to check and verify all of the dimensions prior to pouring. Any de- viation from these plans Salt be approved by 050015 in and King County Building Department. FILE 3.0 FRA00100 1. Stairway: 7-1/2" maximum 4.se, 10" minimum run. 2. 8" minimum headroom for stairways. 3. 44" minimum clear width on required stairway. landing balcony or exit hallway. 4. All bearing and exterior walls shall h, 2"x4" studs 16"on center. All non bearing dartitions shall be 2"x4" studs 24" on center. 5. Double top ,lates to have 48" minimum lap. 6. 7. 8. 2"x6" stud wall, for piping 7 I.D. cr larger. Party walls: double wall 2"o4" studs with 1/2",ir space between w,11s, insulate with 3" insulation batts both sides. For laminated joists BM use 16d nails at 8"on center staggered. 9. For flush 'raming use Bowman BPL. joist hangers or equal. 10. sudfloor and roOl sheathing shall 50 exterior type glue (COX), e) approved equal. 11. All the fraying shall be plumb and square within 1/8" variance maximum. 12. Install 1/2" Gypsum sheathing in all exterior walls, under Tcx 1-11 p10000d siding. 13. Block joist solid over bearing walls, der H.B.C. Sec.2517(d)3. 14. Provide joist lateral support per 1.1.B.C. Sec.2506(g) and 2517(6)3.. 15. Notches on the ends of joist° shall not exceed one forth the joist depth. Holes bored in joists shall not be within 2 inChes of the to? or bottom of ' the joists and the diameter of any such hole shall not exceed one third the depth of the jo-ts. Notches in the top or bottom of joists shall not exceed one 01001.1 the depth and shall not be located in the mdddle third of the spar. 16. 1057:11 15 lbs. _f,lt flashing around all exterior windows and sliding glasn ddors. 17. All entry doors o'rrall have a 1"x4"x38" hoard drder the alsmalni,.. sill to allow for cardet thickness. They shall be installed with galvan ized casing nails- square and in good operating co..litioa with 1/16" maxima clearance - .round door. 13. Install fireblockirg at bathtubs_ MoviGe 4754ERL FREPLoCK106f13 17. Install vertical 2 at each end of. bathtub for drlall backing. 20. Install blocking I;" from the floor for towel) bars at bailudx., and blockinr, on tod of o,oil neat to soffit In kitchens for up cabinets. 71. Install 7 blscbini to of bottom plate on 1,011 behind 1,,s to install / door stopp,r 22. Cut all the 2"x4" bottom plate across all the interior swinging doors and leave plate in on by-fold and by-pass doors, if light weight concrete floor is used and remove all plates if gyp floor is used. 23. Install 2"x4"x60" plate, 30" away from and wall on bath floor under the bathtub only if light weight concrete floor is used. 24. Install 2"x10"x14" block on bath floor perpendicular to wall for toilet blocking, only if light weight concrete is used. 25. Install double joist under parallel partitions. 26. Double 2"x8" solid blocking at bearing walls under a post concentrated load. 27. Installation of Windows: First_ nail the sill, level, and proceed to square the openable side nailing the vertical frame, close to the top. Nail only the sill and the sides but do not nail the top side. 28. Installation of Sliding Glass Door: Follow same procedure used for the windows. After installed and plumb and square, install the screws around the jambs and provide wood chims as necessary. Do not nail or screw the top side. 29. Naifing Schedule Per U.B.C. Table No, 25-Q. CONNECTION 1. Joist to sill or girder toenail. 2. Sole plate to joist or biocking,face nail 3. Top plate to stud,end nail 4. Stud to sole plate 5. Double studs,face nail 6. Doubled top plates,face nail 7. Top plates, laps and intersections, face nail 8. Continuous header two pieces 9. Ceiling joists to platejoenail 10. Continuous header to stud toenail 11. Ceiling joists, laps over partitions face nail 12. Ceiling joists, to parallel rafters, face nail 13. Rafter to plate, toenail 14. 1" brace to each stud_and plate,face no 1 15. Built-up corner studs 16. Plywood (*e) Subfloor,roof and wall sheathing (to framing): 1/2" and less 5/8 7/8"-1" 1-1/8" - 1-1/4" 17. Panel Siding (to framing): 1/2" or less 5/8" NAILING (.a) 3-8d 16d at 16"o.c. 2-16d 4-8,toenail or 2-16d end nail 16d at 24"o.c. i6d at 16o.0. 2-16d 16d at 16"o.c. along each edge 3-8d 4-8d 3-16d 3-16d 3-8d 2-8d 16d at 24" 0.0. 6d (*b) ad (*c) 8d (*b) 10d (*c) 6d (*d) 8d ( Footnotes: (*a) -Common or box nails may be used except where otherwise stated. (*b)-Common or deformed shank. (*c)-Common. (*d)-Corrosion-resistant siding or casing nails conforming to the requirements of Section 2516(j)1. ('e(-Nails spaced at 6 inches on center at edges, 12 inches at intermediate supports (10 inches at intermediate supports for floors), except 6 inches at all supports where spans are 48 inches or more. For nailing of plywood diaphragms and shear walls, refer to Section 2513(c). Nails for wall sheathing may be common, box or casing. FILE 6.D0 Electrical subcontractor shall wige,the OifiiIdinoj dOoqudlOT750 ,plet0, 'tions, and the State and King Co4exellectXlca 'Code and InseeOtlphs.: " - , = , All wile used shall be copper ,dte, -. Electrical subcontractor shall connedt ounetS=dishWashert,'garbage thspnxalag range hoods, drop-in ranges and-riptlaater heaters- Electrical subcontractor shall wily and install all light fixtures and bulbs as per the following specificatiOns. 1. All recess lights as shown on floor plans shall be Paid NO.301 open with 7516 x30 lamps. 2. Walk-in closets and storage rooms shall have ball with 60W lamp_ FirzcilucAL 3. Kitchens to have 8" white ball with 7514 lamp. 4. 011 stairs shall have Halo 02400 with 75W 040. 5. All lanais to have a wall fixture manufactured by American Lantern 42338E or equal. 6. Each bathroom shall have a fan, light and heat Durp'Combination Unit Broan Model 4164 ith 3 separate switches to control it. 2508 heat lamp and a 150W 540 flood light. Locate electrical panel on 6801.-unit behind bedreom door as ShoWn on floor plans. 8. All exterior lights, hallways, stairs, and yard_ shall be connected to a time :Jock as shown on the plans 9. Nelco electric baseboard heatinc, in bedrooms, fan forced electric heater or approved equal, at living/dinin: byTdectric:Contrac, tor. Units to maintain 70 degredg: at-three -06601 71050 EIbor-in all lrioi-" table rooms, Sec. 1211 U.B.C. 70. Subcontractor shall set range in necting dishwasher, shall install front :Ant:tall andIditirotet range hood. 11. Immediately after comdleting the *ting the subcontractor shall clean up all debr15 .andd site. 12. Subcontractor shall plug all the=holet r.de for.the '- plates and some jOists, with roalAtpol Insulation-tO Inspections. 13. Subcontractor agrees to conplete,the:rough wiriUg obtain electrical 5057000500 aw,r09e1 for coVerwithirltwO oa days f rom the-time of completion of the rof. 74. Subcontractor agrees to corplete the trimming' and insthilat4O5 of all the light f irures and coMpletedthe, job within two date the cabinets and whayl floors are Install,Ki. FILE 5.133 PLUMBING 1. All work to PPR-jay-with Oniform an4E41ding)CddeS. 2. 111 water piping 00 1305 type "N"- Copper All :Water pipitg.- 3. Plumbing subconttactor shall PPPPIY and fol151w04,40p ' equal): , 5 white 0801 05 ColtOn) W41-t valve 027 CW-112 'Coltdn Ware.White. , 18" round, With pfl 1461260. 22 stainless steeL.with Moen stnglehai'471.01.iig; valve, leng Chateau 07536. - 52 gallon National - Electtic with EiV.e.Yeat.,Wrianty Frost Free. 36" x fiberglass enClosOre...with Moen Single: lever 51$ve. . 4. Plumbing subcontractor shall rough in and install.owner's dishwashers and disposals. 5. Subcontractor shall excavate, badkfill and corkeet for all pluMbing pipes under slabs. 6. All se4er lines to be stubbed 30" froM-building as shoWn in plot plan. water to be stubbed Out at o05 . end of the building only. (See water (1lx,..) Bathtub Kitchen Sinks - Tanks - Watercloset Lavatories Hot Water Hosebibs Showers D02-066 74 Subcontractor shall strap and secure all water lines- 8. Subcontractor shall furnish andinttallplate,.ttraps over PlUMbing t111: J'2Dt through top and bottoms plates. , 9. SubContgacter shall stuff all holes Made for the tOP, plates • with rookwool insulatien an reqliterl to MeetXing COUnty 016 ±1 6 + 8 4 Code. 10. Frost free hesebilos per plan and-oWner's selection, t50 6511 as shown on site plan 110.2. - II. Subcontractor shall provide 3" drain and 1" W6000 supply tb , p001. went room, 12. Provide _individual water shut off valve for each apartment, locate this' valve in pantry closet next to water heater. 13. Provide sheet retal strap at studs wherewatet pipe tect from drywall nails. 14. Subcontractor shall provide plastic silenterson watar plpen at oiery other ' stud and joists to eliminate pipe noise.. • 15. Subcontractor shall secure 0-54 all.neceStary perm*ts.