Loading...
HomeMy WebLinkAboutPermit D02-115 - OMNI FITNESS4./ D02-115 Omni Fitness 1171 Andover Park West T - . -i ti �� . Cit o 1 ukwl Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 DEVELOPMENT PERMIT z Parcel No.: 3523049085 Permit Number: D02 -115 .- z Address: 1171 ANDOVER PK W TUKW Issue Date: 05/14/2002 aa Suite No: Permit Expires On: 11/10/2002 _JO O Tenant: co = i Name: OMNI FITNESS --' H ■ Address: 1171 ANDOVER PK W, TUKWILA, WA 0 0 w Owner: 2 g Name: WESTINGHOUSE ELECTRIC CORP Phone: u- Address: WESTINGHOUSE BLDG TAX DEP, GATEWAY CENTER w d F W Contact Person: Z i_... , Name: STEVE DUFFIELD Phone: 425 260 -3060 H- 0 Address: 18715 EAST VALLEY HY, KENT, WA w W ? D .. Contractor: U Name: DACO CORPORATION Phone: 425 - 656 -4505 0 H Address: 18715 E VALLEY HY, KENT, WA w W ' Contractor License No: DACOC * *012NC Expiration Date: 05/01/2004 i o u. r _ DESCRIPTION OF WORK: Z . INSTALLATION OF 19 BAYS OF PALLET RACKING FOR STORAGE OF FITNESS EQUIPMENT. U (I) , . H= O~ Z Value of Construction: $0.00 Fees Collected: $257.36 Type of Fire Protection: Uniform Building Code Edition: 1997 , Type of Construction: RACKS Occupancy per UBC: 25 ' Public Works Activities: Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: , Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N `i" ': Moving Oversize Load: N Start Time End Time: ' , . Sanitary Side Sewer: N ;:� , " : .,�t Sewer Main Extension: N Private: N Public: N Vii '? Storm Drainage: N ze,Z � r•, t Street Use: N - ' ~ Water Main Extension: N Private: N Public: N A 4, Water Meter:(' q Channelization / Striping: ; �>�'!`i ** Continued Next Page ** i` ''. ;„_'xxt�hff: r LL , . xr 1$ • doc: Devperm D02 -115 Printed: 05 -14 -2002 - X;. "; . 1 - tatuEZ fnwma;wwvosoo... ..._.. ,�-- , ,..._.. .. ,,..5.,.....Pa• ,v,. , r.r.,... ... ..,,... _ ..... .. ... . .. ..� --r - - - . ■ OM, w . (: itr.) C ity of Tkl Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Z Permit Center Authorized Signature: r�ei- 4- Date: t5 ��-a--4. �_- Z �w I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and � V ordinances governing this work will be complied with, whether specified herein or not. 0 0 co 0 The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws w = Lu regulating construction or the performance of work. I am authorized to sign and obtain this development permit. co 1_ • LL, w Signature: i� Date: '- /l 9 Ate- 2 0. i -1- w a Pr int Name: ( / S �� = w This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is ? H suspended or abandoned for a period of 180 days from the last inspection. z O w w v 0 0 C . 0 I— w w ■ = U. 0 111 z , V co Z i W?+' 1, y yy fai r ; .. ..'! g br /y . � r ' �K , • N , i5 �i�. doc: Devperm 002 -115 Printed: 05 -14 -2002 ?;•, 1 k • 4.0%.1.-1:3 ■ �`� 4, .� 0,44% � x " - City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 ■ PERMIT CONDITIONS z ~ z Parcel No.: 3523049085 Permit Number: D02 -115 w Address: 1171 ANDOVER PK W TUKW Status: ISSUED 6 Suite No: Applied Date: 04/30/2002 U O Tenant: OMNI FITNESS Issue Date: 05/14/2002 to 0 W� 1: ** *BUILDING DEPARTMENT * ** w u_ 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. W 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These g 5 documents are to be u.. maintained and available until final inspection approval is granted. 0 g 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as 1 W . amended, Uniform Mechanical Code Z I (1997 Edition), and Washington State Energy Code (1997 Edition). I— O 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a W W permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to 0 u) give authority to violate 01-- or cancel the provisions of this code shall be valid. w w 6: ** *FIRE DEPARTMENT CONDITIONS * ** H C u. 7: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: ~ O 8: Maintain fire extinguisher coverage throughout. LLi Z 9: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 0 10: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel • 0 H shall also comply with Z the Building Code requirements for accessibility. (UFC 1204.1) 11: When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the , direction of egress. (UBC 1003.2.8.2) 12: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1) . 13: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written ' approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior •:;., to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) :' 40,1 14: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and . . 'N; h.,, #1901) fr - 15: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) ` "i ' v1 ; . Y � ix4.crX f 16: In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or ' at rack uprights shall be , #', maintained. (NFPA 13) ` ` r IC +'.. 4 sj;, 17: Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 13) �'` 18: Storage may not be closer than 36 inches in all directions to ceiling -hung "Space or Unit" heaters. (UFC 1109.2) ' "'�� J s2 , a of idle (un -used) pallets is limited to six feet in height by the Uniform Fire Code. If storage quantity in excess of six feet '" " "` " 19: The storage g g Y g q Y ..s in height is xt, , doc: Conditions D02 -115 Printed: 05 -14 -2002 ::! v 1:a. I ` - - ' _ ` 4 &N OMA h. , . .# .., City of Tukwila me t Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 required, outdoor storage must be utilized. (UFC article 81) (NFPA 231) 20: The critical storage height for high -piled combustible stock in closely packed piles is 12 feet. (UFC 9.110) Storage above 12 feet Z may necessitate increasing , = I- the sprinkler density to extra hazard and adding smoke removal capabilities. (UFC 8101) (NFPA 231) Ili 21: To use any building or portion thereof exceeding 500 square feet for the storage of high -piled combustible stock. A floor plan 6 showing the dimensions and U location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 8101) N a 22: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible U) w . materials on pallets or in racks _J H more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, N LL . etc., the critical wO pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) 23: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of u.. < intended use. to 0 24: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such = w H condition or violation. Z F,. 25: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575- -. O 4407. W I— w DO O - I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances w H governing this work will be complied with, whether specified herein or not. = 0 iF The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws LL . Z regulating construction or the performance of work. U to r Z Signature: , ,_ •1 k IL Date: .� Y/7 c)-- . Print Name: Q (-F-( `P C ‘4 �&Q- 1 °`1, nir : g ei: ' VVIIIH :11q r 7 doc: Conditions D02 -115 Printed: 05 -14 -2002 'b , :'.'r ,, s': tie'• „i•Y ".:).,7,1. f..it+..?y .,.:.:,s„ a* swne... aw• o s,.+. es:,.. w...,,.,.:.. rx..:: ae,- �r ..rr.,: ^.e++r< + ... .......... .. , 40 CITY OF TU "WILA a s % o Permit Center Project Number: ir ;iit ? 6300 Southcenter Blvd., Suite 100 _ ilia Tukwila, WA 98188 P ermit Num • ait s, (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name /Tenant: V lue of Construction: Dh1 n i ) fines$ ' i f, a)() Site Address (in Iude suitK number) City State /Zip: Tax P rcel Number: I I I 4►-tdo ✓ec t j/L Wes Tule wile- ‘t// yAi/P 1 ,J.Z.F.0V 7DoPff ` Property Owner: Phone: ■ Street Address: City State /Zip: Fax II: Contractor: Phone: n/3-co Cc'v 9 iL/ c& - yS oS Street Address: ! City State /Zip: Fax #: /7 /s" t'v 1/a /1y ,'4v ,/;,t1 wig Are.„7Z 125 /G /s _ e, - ''S-43 Architect: / Phone: Street Address: City State/Zip: Fax #: Engineer: Phone: , Street Address: City State/Zip: Fax #: Z Q Contact Person: Phone: I Z i� Do e ( 7) '/ r/z 6,o -30 6, 0 LU Street #: 0 Address: City State /Zip: Fax # 1 7 / s _ /,. J / 4 / l z),9 9,e632_ - 9J_ 3 _J o Description of work to be done ( lease be specific): a.�7dZcE 1 W l/1S> a'7 to o/ 44 / 71.1 c/ - ` �" /9 J J di WO Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family 71 Warehouse ❑Hospital 2 ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office W ❑ School /College/University Other — 2 0 Proposed use: ❑ Retail 71 Restaurant ❑ Multi- family F2 Warehouse ❑Hospital Z H ❑ Church ❑ Manufacturing ❑ Motel /Hotel El Office ' O ' ❑ School /College /University ❑ Other w ~ Building Square Feet: /3/00P existing No. of Stories: / Area of construction (sq ft): 7 V Ca Will there be a change of use? ❑ yes in no If yes, extent of change: (Attach additional sheet if necessary) p 1- ' W w W ill there be rack storage? 71 yes ❑ n = 1- o 7 . u. 1 " — Existing fire protection features: ❑sprinklers 71 automatic fire alarm ❑ none ❑ other (specify) Z to Will there be storage of flammable/combustible hazardous material in the building? ❑ yes al no 0 2 Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Z H APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling , ❑ Fire Loop /Hydrant (main to vault) #: Size(s): , ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent #_ Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ,.‘• . e 0. . 4 ., ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The I '1 building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. N am ; Date application accepted: Date application expires: Application taken by: (initials) Jc _2 /o -e —,..2-- ofirS' PLEASE SIGN BACK OF APPLICATION FORM ` 11/30/00 clpenuu,dac I APPLICATI S MUST BE SUBMITTED WITH THE LLOWING: > ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER »' ALL DRAWINGS'S AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, 1 Z identify by size and species which are to be removed and saved Z Z 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) QQ 11. Location and gross floor area of existing structure with dimensions and setback J 0 12. Lowest finished floor elevation (if in flood control zone) 0 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). W = 7:1 JI._ Floor plan: show location of tenant space with proposed use of each room labeled F ❑ O Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of n any hazardous materials; dimensions of proposed tenant space. g 5 Li. Q ❑ ❑ Vicinity Map showing location of site s d 1— W ❑ CFI Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack Z layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of Z 0 rack. Structural calculations are required for rack storage eight feet and over. ui uj ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished U m ❑ in Construction details 0 11 Ww ❑ CO Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water t=— H supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed u- Z sprinkler system design criteria as identified by the Fire Department. W N U = ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. 1- F- ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). Z El ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal ailw I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF I Ij PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOR! ED AGENT: I ; Signature: / 417 h Date: � e l ■ Print name. t CCC���"' Phone: y r _ / ._ m ax #: 6 r cp. ept en Address City/State/Zip 1V / 5 Fc f) b Ay ca y Z r� Cam., 1,,x/9 7803 Z •w, ... P.m ..1 11/30 /00 ' 1 cipermii.doc AM N , ✓kP.v +.....a.. .uN.. 'Y' y ... . <....... ... _.. _ yyii*rot. .rp nN , ..•1'. r ,. uy.+ t.s .. .., ...r ,r. :t l.?lA.t .c tLSCC(9,F °. •'}'.r�i4 _.... .. r....,,_. ._..._ .... , , " r s.., ......... 8.40. .1 ,,si ,„„ .. . too; City of 1 u.kwila 0 ,.... - .0. 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 z RECEIPT 1 ...z • al c4 2 6 = Parcel No.: 3523049085 Permit Number: D02-115 _ o o (00 Address: 1174 ANDOVER PK W TUKW Status: PENDING co w Suite No: Applied Date: 04/30/2002 cu i Applicant: OMNI FITNESS Issue Date: co uj 0 i 2 . ; Z I- I Payee: DACO CORPORATION 11.1 ill 2 D „ I n 0 o c o 0 — TRANSACTION LIST: ,0 i-- j w Type Method Description i ID o Amount I- r - I U.I6 Payment Check 113330 257.36 iii Z 0 C -2 . - I 0 I Z ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000/322.100 153.25 : PLAN CHECK - NONRES 000/345.830 99.61 STATE BUILDING SURCHARGE 000/386.904 4.50 Total: 257.36 44?„ort." i ta i'AVn;4 sp fit , . V. 'IN/ • . O agi C rittiW 4 1 71 l'; T(Tillf ::`77 • .5( 'iVikal,0 doc: Receipt Printed: 04-30-2002 „ ,,,....•..,. , . • .,• .. .. , • , .— -, r -' S • Z . f— tZ CL . J U ``_ INSPECTION RECORD 'fj b a — f CO LU t Retain a copy with permit _ 1 INSPECTION NO. NO. u) u. f O 0 ' CITY OF TUKWILA BUILDING DIVISION 4ERMIT P _ 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -36 � Proj� F H't J 4 ' T YPe of Ins ea r ��C� d A d s Date calle Z x Special instructions: , Date wante Z I— -_ LUw Request ❑ ❑ ,' II U ❑ tj. Plso e: O � t.:. w -,-,:.'t, Approved per applicable codes. El Corrections required prior to approval. I ;r. COMMENTS: 111 Z ,.:.; • if , Oe'revk t---0_s2...ea I-- 0 I— VVV ti . K , 1, ■ 1 pp Ft W M ' It IP C4' L ..1 = r . - ;k f a = ,..., ' Inspector : Date: 5 _ - Li _ a , ` ' 0 7.1 REINSPECTION FEE QUIRED. Prio, to inspection, fee must be paid :4= �{{ ,f: " � � 1l .1 i Y . .t r Southcenter Blvd., Suite 100. Call to hedule reinspection. = r "R is =� Receipt N Date: 1: ' 4 — ,1' 1 n5 f x 11 . i ,.':i':..1'4. .' 6..; ... . -4 , ; , , .; ,.,,, H. rz:. s} S' I. ViNVAfw,Iti'V4'iatiV !a61 ,A2.- Ync.'nsar3•Ntv3wtatdau+R ,rrc.AaaaMra. -....• ';.`: 'P*' t "' 1- e ttigtoftt; 0 •" rl••.4�d�*1' ' Airobee, ■ . , . - - .- - •.. r t- Z H W _. ' / �`'� _J 0 INSPECTION RECORD / u W • Retain a co wi permit t✓ ` ^ � /J J copy P co INSPECTION NO. PERMIT NO. ! o al t; ; CITY OF TUKWILA BUILDING DIVISION • :,' '6300 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Q • Pro� T q�of I / / e n: ct•o to .I , • !C fit• ? /7/ /j7 n esf c y / G P 7- A eF . = a e _ A ens Elate c Il '� 1 1._ Z' . c , '� I 4r) G&W K 1 / 6242 /G 4? � / 0 •-•: instructions: nte S • p i Date wa '�:": Z O Y .� —/93/; J� p.m. W `= C- Requeste • > • tc-G� fic:� 0° o Phone: _ 7 �� O E- .:,. W • 4 =W r {;, _ 1 U 1 Approved per applicable codes. Ix Corrections required prior to approval. LL 0 Z k''. • COMMENTS: • lii U cn 12 ) Pos. 4- /(3 4 -f , os o 1 Z ;;F ' c / E. t ) Ai i I •-- —/V y • — ij eC:1 . : )l V • i y.' - / f' . 3 �}/t/CP D-4 /n/ / .S Qe' d• it—d p VV� / ; • L ' '` . ni .. 1 i spec Date f � �. M 0-_ $ .00 REINSPECTI N FEE REQUIRED/. riot to inspection, fee must be paid 6300 Southcente Blvd., Suite 100..Call to schedule reinspection. �; Receipt No Date :� } 1 11 0 S.Z;, ... J .v •r.x3pq,YNu}; ;A FtiSgiWAA..0 xttfitWAVI M,4A'4A0.0ct:S0.tkX, Ys;f Yea ... ;. I. ■ n4' . , V i,. . 1..,arv,�. 7: 1 1, ' a R J!ft Mu _.rw.. 3x ' ...,r'*(Ah'� x4}"tt'�'�!• p.�' �?':'3.. • D1i«t3 ..r . 411 ■ - - - - "-- .- .'"?' ' '''.r 7 7 71;7 ' ' . i . ■%.7 77 7 -77 7 1.7: .".7 ' 77. ,;`!",-; ., .7. , . 3 7;7 7-7-7 7, . c \ , 77777 . . .-”. . i - - t7 ----- 7 ----7---=- 7 . ......„, -,..... _, --- *ALA , t , .. ...- N s4)...........; *".. is, City of Tukvvila Steven M. Mullet, Mayor ; 4 : 4 ' ■ iiii — 1 ; '• tlr's :4 kftk / I Fire Department Thomas R Keefe, Fire Chief 1 ., ,INC• ................. ...'" jac,- z < . , XI— I— z w re 2 TUKWILA FIRE DEPARTMENT 6 = FINAL APPROVAL FORM _10 O 0 u) a co W WI . . . 1 Permit No. 00)• I ij...-- ,--I I.-. w 0 2 g 11 u.. < w D "f CI w I z F.. Project Name C.7(1 ti , F, 1 " 0 S S I 21 flids 'IlS z !- Address 1 "/ -it-% et Oe f r— Gi.../ i4-•—# W u j 2 D no O - . ' uj ol-- w Retain current inspection schedule i 0 i-- ..N Needs shift inspection - 0 W i . 0-v2 0 \*/( Approved without correction notice z Approved with correction notice issued Halon: Monitor: Pre-Fire: Permits: H 7- .AWRIP c 4=0,640: ,.... —•"\,;.'P S) ) <— - 1 -‘. ) 7 . -- v,,,',,,,l.A.43. Iri lr Authorized Signature Date 1,, •.-, .r,„:,,,,c,,, Iiii oN: I':;:'-'0-' •••!.'::, FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 I ., ,,-,,,,, i•- giPif:',iiii■ PAW,At ‘ 411 1 1 , 111147, Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206•575-4404 • Fax: 206-575-4439 ., . YA:1)411. 1 — - - - .. — - - - - -- .__ ■ • • • • � ' MAC a 25 . .• • A z • . ti p. 4 . 16 • 1 /.. h 2 6,� r PG 2 , ` aa . J / . / J U Il U0 w co ~ +^ J Co ui ~ l 1 �I� PP t- FILE COFY ' i •.. •i . r`�.� ,.n-�- !}� Jft17 ere 1 a Z F- N RECEIVED ri lff CITY OF TUKWILA RR Id tg PPR302002 �rti • �- • ==1 • 4 � ` & . .. �/ PERMIT CENTER *J F>o$ �' DOCK NIGH DC 1 f:; _, . y SOUTI-{CE WEST E3US INESS PAIR< \v/ ,�� Door 4 f .,•• N OVER PARK JJEST BUILDING 5 �,. a , f.., 11� 1 D DRIVE IN q .:s�.�.� { :.�tf � : �7 �� ;:, :;ice- �, +' f rt11KIiii'LL,�. ,145 INGTON 0ZOOZ .- 6 K A • TO 39Vd SS3NlId INN° T59b98bS /be 'as` f nnw` !Ik✓cWn6f ^S:nucv!:van+wu�.r'.,M.w. ::xrn.Frr.N :. t . n ..... y . ............... ....... ... ..... ..:. .... � , . .,, .,; ..: , :: „� +., . y.r . .yr.r. I - r -, .1/ — APR -09 -02 13:46 FROM:EQUITY OFFICE ID:4254671635 PAGE 2/4 i Z re ii. (\IF I . . CO • O . CO LU J H (0 u_ WO 2 qq u.< f f 2�' -�VI 0� T l)44N -� = d N TR U • _ • • . z� , Mp, - 8 240 W W • 14Ut:U U O S I J W Z U' F- M LL 0 (: - 4 - Z • . 1 �.. ...._ ~ O H . . a Z 0 i RECEIVED ' CITY OF TUKWILA ' \ RIR APR 3 02002 IA ,..;.,:,. RR PER MIT CENTER I .,,.:-.,...,..t..., ;,;, - f•: • A ,� A A :� , . i IF DOCK I4lG -I DOOR r ' SOUTNCENTER WEST BUSINESS PARK RAI DO � „,;,�• i , 1i1l ANDOVER F'4RK WEST BUILDING S '' r'` ' 0 DRIVE IN DOOR p.. • NORTI! TUKWILA W,45-IINGTON • , . . snz�+ . M 4fpYS? � .. J • iXe -°. ' f R* M•' x . w.... e,......... n.«._ ................r... rz.. rS'.• �.. .......:�......�r.........:..., __. _....:. -.__� -- ..:............:._....�� i 7 — �lr S APR -09 -02 13147 FROMIEOUITY OFFICE ID +4254671635 eAut. LIwv . EXHIBIT "A--1" , THAT PORTION OF THE SOUTHWEST'/. OF THE SOUTHEAST'/. OF SECTION 26 AND OF THE NORTHWEST Y. OF THE NORTHWEST V. OF SECTION 35, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., ' IN THE CITY OF TUKWILA, KING COUNTY, WASHINGTON. DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHEAST CORNER OF SAID NORTHWEST'. OF THE NORTHWEST'' V. OF SECTION 35, THENCE NORTH 87° 44' 08" WEST ALONG THE NORTH LINE OF SAID NORTHEAST' V. OF THE NORTHEAST' V. A DISTANCE OF 30.00 FEET TO THE WEST MARGIN OF ANDOVER PARK WEST; Z THENCE NORTH 01° 47' 29" EAST ALONG SAID WEST MARGIN A DISTANCE OF 115.66 FEET; THENCE < • NORTH 87° 55' 02" WEST A DISTANCE OF 115.66 FEET; THENCE NORTH 87° 55' 02" WEST A 1... Z . DISTANCE OF 494.10 FEET TO THE TRUE POINT OF BEGINNING; THENCE SOUTH W CC q 2 ' 01° 51' 03" WEST A DISTANCE OF 797.00 FEET; THENCE NORTH J U 87 55' 02" WEST A DISTANCE OF 216.00 FEET; THENCE NORTH U 0 01° 55' 03" EAST A DISTANCE OF 797.00 FEET; THENCE SOUTH � W ' 87° 55' 02" EAST A DISTANCE OF 216.00 FEET TO THE TRUE POINT OF BEGINNING. J H s N • W O 2 ga 0 d . z • W _• ZI I — ! WW D p U O N O I- _0 W° o I 000 ... : z w 0 0 - Mpr �, RECEIVED CITY OF TUKWILA APR 3 0 2002 PERMIT CENTER . f x � • y PLEASE _a , INTIAL j :'`s'', aLORD 'k ' t an% ,m ''',. ,"." 22 to r, '.'.. +inn iA`J.i i'+{;iae.+'. Ni rtiwrx,CA.I'..:zn•s'�v u.•.S.`kSa.•i1," +na•min+ .. ;. . ... .. .... .,r . i .... ... ,. ..... .verws+.., on.m hwr..,rrw„s .: •.,.•r.... ......... ... .. .; �yyh,MY1.'dW' • lit. 7a. CLw! wwRKWA) N�1i�517° I( I � .N",•ndlSTA•'D. t .. . _ '". I E t ityv4 III ..... ....., ...■ " .....' 110,- 41 r -___,. ) ,____,x, _ I c • t u.. < I 3 D • ,. W D I c/ t 1163 3 t-- U • 1 1181 =1 -, ..a.. • = ! Z I- ...._ ___ .._..., r--.. 1 g li i s 1-•' 0 .-. t -.... • i : I 11 1165- 1147 • ff-- ce O.;..0 I L1.1 ill I 2 D I RH- p 1183 ce i. n CI I ; I t . - 1165 :: • 1 4 1 •w • >„.., ‘.., t 0 " CO I ...? - us- Liu ca 1115 E ,Iff 4 Z I, 0 I' P a } LLI u j C 0 95.3,11 al g r /7777 1167 .A /3 WI N • I I ; I 0 I -. IL. I E . "" I I CI° Cj W416. 1*44 0 ° Z 1149- 1 - B . ! Il i ( i 1151 • 3 7; •vw 1 , 1169 1187 1 .0 ia Itta . 0 . • I tINM 1.) Z I a E [ i 1 D lik11.11: 1 119 1 1 C ..,..gr1 I • 1G I I 1159 E 1 _ _ t 1177 '—' , 1191 I ,. i ... ....... . L j \ i ? TRIIAND DR. t --.... LEGEND A DOCK-HIGH DOOR I RECEIVED ; i 1:3 GRADE4EVEL DOOR A CITY OF TUKWILA Wi RAMP W/GRADEIEVEL DOOR MP 'i't ANSZ rri ,... .: • RAIL DOOR i APR 3 0 2002 liiPPT. PERMIT CENTER e rn ! ' , Ya , •,„.. PLEAst.: :.i ,,;;',. INITIAL 1,1'`i:?;',V,. -,,. .. , "74: , 6":':7 . ( ll Am, t 1#0,./ Vitg , • V,V • 1. .:, ;4;4014 leg.,•• VO {gal t...S, 1,,,,• • , ' ' ' ' , ' ''''' A' ' 0 '' '1'1 t BY G. OHANIAN F K DESIGN Sc ENGINEER ; CO. SHEET NO. 1 DATE 4-15-02 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 JOB NO. RD -6751 SUBJECT TEL:(818)957 -2980 FAX:(818)957 -8603 Z Q CAV (' 1 W A Ix 1 m STRUCTURAL CALCULATIONS OF vim " $ 2002 _J o STORAGE RACKS FOR: w i �1L0t tC CO � . w _, • 1 BY G. OHANIAN RA` : DESIGN & ENGINEERIN CO. DATE 3788 LA CRESCENTA AVE., SUITE 204 SHEET NO. 2 GLENDALE, CA. 91208 JOB NO. RD -6751 • SUBJECT TEL:(818)957 -2980 FAX:(818)957 -8603 96" OR 144" 44" Z LB689 BEAM H Z 4 W co 30 00 # /LEVEL +25% IMPACT LOAD "- 1 II 4 1700 { d # /BEAM U O I =a.s J i Sx =1.6 0 i ) I II 4 N • J a te . M = 144 1.7 K = 31 � K W d = W i c' a S 31 "K = 1.1 Z 1.- R 30 I— O LU ;.. .... „ , ° } f 0 = 5xWxL = 6 ,, < 144 = .8" LU W 384x1 xE 180 U 0 N 0 9f .. I— BEAM W W 2000 # /LEVEL +25% IMPACT LOAD fi , „4 U 1300 # /BEAM I I M= 96 "x1.3 K = 16 "K �- ~ O I 1 8 — Z Ix =1.7 S — 4L ,. 0 "K _.5 U = UBC 1997 SEC. 2222 S =.8 R — 30 0 F Z SEISMIC DESIGN Fy =50 KSI. A _ 5xWxL = 4 ,, < 96 = .5,, 384x1 xE 180 I, 2 3/4• 1 V= 2.5xCax1 x w R'4 WORKING STRESS 1 =1 R =5.6 LONGIT. DIR. (MOM. CONN.) R =4.4 TRANSV. DIR. (BRACED) Ca =.36 . i W= D.L. +L.L. K "K LOAD PER COLUMN .=, ' in% ., 4 K P= 2x3 =3 K :r ; " �' . 2 `° . W = .1 + 3 = 3.1 K 1 5 K s "K = -K 16 '" ;x £41 O.L. L.L. 2.5x.36x3.1 K .7'. : .,... \ LONCIT. 5.6x1.4 ' 35 1 L VTRANS. _ . • kq fn 4.4x1.4 f �� .35 1 K ` r j4.i ` y;;r : 1 _ r I _. BY G. GHANIAN RA I. DESIGN & ENGINEERIN. CO. DATE 4 -15 -02 3786 LA CRESCENTA AVE., SUITE 204 SHEET NO. 3 GLENDALE, CA. 91208 JOB NO. RD -6751 SUBJECT TEL:(818)957 -2980 FAX:(818)957 -8603 v COLUMN ANALYSIS Z I-- Z 3., F SO KSI K I = 96 = 80 Fe= T E 2 = 45 re g A =.8 (rx) UU KI = 50 Sx =.8 r 1.08 =46 Fn =Fy F )= 3 6 Ks1 N I x - - x y 4 F e co = .. rx =1.2 W f r \ t =.09" 1 r =1.08 Max =S x•Fb = 24 "K Pn =Fn xA = 29 K N o . W _= Ph = K 2 • BY G. GHANIAN RA DESIGN & ENGINEERIN` CO. 4 a 4 -15 -02 3786 LA CRESCENTA AVE., SUITE 204 SHEET NO. DATE GLENDALE, CA. 91208 JOB NO. RD - 6751 SUBJECT TEL:(818)957 - 2980 FAX:(818)957 - 8603 TRANSVERSE SEISMIC (OVERTURNING) Z Z Mor = .45 K x2 x 180 "x.5x 1.15 = 93 "K a 2 o l. 6 = 0 00 MR = 3.1 x44" = 136 "K (0 0 (0 W NO UPLIFT 9 j LOAD TO DIAGONAL q I g R/ p BOTH SIDES TYP. P =.45Kx c oL. x 42 = 1.3K I/13 r1.5' ` .) ❑ 1--X W . KSI ( A ❑ - F " p Y F 50 N _ � - h Z f' KSI \ x x � W A =.31 F 11.2 -4 ❑ ?p . I =.07" r =.48 P = 3.5 K SEC. A —A , � ❑ p � . Q =.74 a 11• 0 H I / W L= 56" ❑ 0 u-p I TYP 1/8 1.5' W N I CHECK WELDS 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3= 5.7 K SEC. B —@ CHECK SLAB 3100 3100 °' a 1 1000 = 3.1 3.1x 144 =446 5" CONCRETE SLAB 2000 PSI. CONC. 1000 PSF. SOIL =21" " ' 446 =21 • • ♦ 'f t 741 M= ( A. 2 — ) x1000x Z x12 = 735 �, fv =WI 6.3" 4.2" s 12x5 2 =50 1!i 10.5" 10.5" �z' l 735 21 " 50 = 14.7 < 1.6 ../2000 = 72 } s; ;"d ,'i: ... ✓_•. T- x4.'.. : id,tt.tWy' ..e.,' . "Itd'tF'l,A'I/Y9%Y'!inLl. m, ... "s.. a.A• J • :'G MLYGw;n.x, + , .y. .., .. •_ .., .. •. . .. -- - , — . I. t — . ,1 •H PERMIT COORD COPT PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -115 DATE: 04 -30 -02 PROJECT NAME: OMNI FITNESS z SITE ADDRESS: 1171 ANDOVER PARK WEST ~ w -J XX Original Plan Submittal Response to Incomplete Letter # ti O rn o co Response to Correction Letter # Revision # After Permit Is Issued z H— CO O • �.. p Permit Center Use Only ul U — INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: O H - Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Z TUES /THURS ROUTING: Please Route [ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 5 -30-02 - Approved ❑ Approved with Conditions Z Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: ;4r :{ 1 - 41 1 1 k 4 Permit Center Use Only yY CORRECTION LETTER MAILED: ' °,' 1I 1 ..,vi„, , Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Y ,:,, z . ; 1 r i f kj: :K�Vi17� COORD `rt ' " : Documents/routing slip.doc �• 1 G oti �}� r „� { 2.28.02 L " :S % ,tr tt ' br- r. 1„,. i' �. � gfGi�Fgl �..a,...,. � yq' k��..^ m. 1��. wwna. n�. .- nr+...en..nnn.- r.u.u.......:. r .., w�. u.. n. ......i.....��..- ..a.�..lv.... ...... ... 1 - i _r . 4 \ PLAN REVIEW /ROUTING SUP ACTIVITY NUMBER: D02 -115 DATE: 04 -30 -02 PROJECT NAME: OMNI FITNESS z SITE ADDRESS: 1171 ANDOVER PARK WEST W XX Original Plan Submittal Response to Incomplete Letter # _i 0 0 Response to Correction Letter # Revision # After Permit Is Issued w w CO u_ w0 2 DEPARTMENTS: Q Building Division k Fire Prevention ❑ Planning Division ❑ c a = Public Works ❑ Structural ❑ Permit Coordinator El Z w H I- O ZI•- DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 5-02 -02 IL uj U 0 Complete " Incomplete ❑ Not Applicable ❑ 0 co o'— Comments: w w I- r 0 Permit Center Use Only .. Z INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: . U O ~ Departments determined incomplete: Bldg ID Fire E] Ping ID PW ❑ Staff Initials: Z TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required 5( REVIEWER'S INITIALS: PW\.- DATE: 5' 11,.. 1 P2- APPROVALS OR CORRECTIONS: DUE DATE: 5-30 -02 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: �`" .'., t - REVIEWER'S INITIALS: . � _ DATE: ;) 1 2.- O2 ,;P tin y:,:: 1 -; Permit Center Use Only _ CORRECTION LETTER MAILED: ,4 .4„,f.A Departments issued corrections: Bldg El Fire ❑ Ping 1:1 PW ❑ Staff Initials: cin Y . ; r Documents/routing sllp.doc _tri 2- 28.02 : wdrr,.'::?, i ,,„ : ��iyd: "yX etZ ,k. ■ ,''?R'MT.>��i '. ,..,. ..tU ✓!(iYdlF�Y'IrcV:... �...�. hSd.KSMM«ye..war.......,... , . �.w...... ,.. _— _ - - � r 1 _ -. ` ❑ 1140 Pre-reroof ❑ 10034 Removal of septic tanks require approval and k ❑ 1400 Final -Fire compliance with King Co Health Dept. �T. 700 Final- Building ❑ 10035 Contact PW Div to obtain,insp for water /sewer connect ■ 1900 Final - Reroof ❑ 10036 Manufacturers installation instructions required on site ❑ 3100 Site Visit ❑ 4000 Special- Concrete ❑ 10038 A C of O will be required for this permit ❑ 4001 Special -Bolts in Concrete ❑ 10039 Final approval for all TI w /in the limits of the SC Mall ❑ 4001 Special - Mom/Resist Conc Frame ❑ 4003 Special -Reinf Steel Prestress ❑ 10040 All construction noise to be in compliance with 8.2 TMC ❑ 4004 Special - Welding ❑ 10041 Ventilation is required for all new rooms & spaces ❑ 4005 Special- High - Strength Bolting ❑ 4006 Special - Structural Masonry ❑ 10042 .Fuel burning appliances ' • .V.4>;! ` '' ❑ 4007 Special - Reinf Gypsum Concrete ❑ 10043 .Appliances, which generate ❑ 4008 Special - Insulating Conc Fill ❑ 10044........ Water heater shall be anchored:•x^!i� {i� ❑ ❑ 10045 Reroof 4009 Special -Spray Fireproofing :. � e:3 4010 Special- Piling, Piers, Caissons ❑ "Anchoring — All new construct and substantial ❑ 4011 Special- Shotcrete improvement shall be anchored to prevent flotation ';f ❑ 4012 Special- Grading, Excav/Fill � ❑ 4013 Special- Retaining Wall v ,.-' ❑ 4014 Special -Panels Plan Reviewer. i Date: 0 2 'µi - I ` "�' +i ❑ 4015 Special -Smoke Control System CT-2, '07i I s'i'r { >'',` Permit Tech: Date: ?: r " 4:. : _ , r' -:', : a i . t i 4 1, :,311i ,.:r ua•{,«�"4.I,ClI,V...•iy ay„.K... +t,;�:•r.. r: >..�,.'.: .. :/biyes cM,,,<x::. •rur:: gn .. ,.....,.. ...: .. ... ..... .... .. .. ,.....w> .. ... ... -..... te r - - . _, 1- 2 ILI Public Works ❑ Structural ❑ Permit Coordinator ❑ ? I- F- 0 Z I- W W DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 5 -02 -02 U 0 rn Complete ❑ Incomplete ❑ Not Applicable 0 .., H Comments: 1/1 V I- H Permit Center Use Only U CD INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: O H Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Z TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 5 -30 -02 Approved ❑ Approved with Conditions X Not Approved (attach comments) ❑ Notation: 4.0-03 REVIEWER'S INITIALS: /"5'(V DATE: f /2 /, ?.. -- '° Permit Center Use Only °; / �,S , �:tl�t�r, CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: - I r ^ , y ' . 0 I 11; Documents/routing slip.doc c *&! 2 t.. A 2-28-02 qm .„..„ ,,..., 7 ...,. rrr w, r nr xrxM ,...n�a. ,..,sv„44,4,.. ., ,, *r?n :fi„..t.„ ,,. ,..... ...... .....___ 1 Z - ~ Z re . 5 .J U ' o N J= F- Q. W O • 2 <5 • LL. Q Z C� I-- S ZH H-0 '. •Z - . W IMPARTMENT OF LABOR AND INDUSTRIES �..� ~.___,..._.....�.. ? Q • O ; VO In 0 I- , 02 REGISTERED AS PROVIDED BY LAW AS I = U CONST CONT GENERAL . .. . ;,... —O • REGIST. # EXP. DATE tli Z CC01 DACOC * *012NC 05/01/2004 U N EFFECTIVE DATE 09/10/1999 r -- . Z DACO CORPORATION • 18715 E VALLEY HWY O KENT WA 98032 -1241 u CC . . • w X . cn . 2 H t, .„ • O ; O 1 1 N �x� s" ..;.•.• •. ... .,.; �•,.. • ... '`,r u.'.,.;: f• �r. 1. L. K:: tii3tui+ f7Y.. kJ11td .�,GS:.::r <::. � 1uY.!a.r.Fa•a<.IYn 'iwv.. ... �..,sno »rwlyx_w+ .,"'•...�a„_�•,s .... ..,._. _...,.. ,......,..... .,_. -. ,. ..r.a v�y,,. e,• rn<. r .•c,+�s�t:bw,w§NGftfi4ML1.7ifl1.� 1 e'' , - v . - ---"K Z re ~ w D JU O 0 w 0 u) LLJ J = H W D M LQ 1— _. Z1.- I- 0 Z I- w w U steve duffield O — O H W W s:.... - • � _ .,Z v cn P I Z Balance Due: $ \61% . • • Need Current Contractor Registration Card: Yes Q No X ' (a N eed to Enter Contractor Information in Sierra: ► ;1 Yes ❑ No • ��. . 3 „, 4 , ;;,; , ,,t2141•6',. w ............ .:::.. > .., > ;, .: ...:,:.. r:. . ate... ............................... .,a. 0. ... .......,........ .. o tac t,.. t' ensc�r�:::: �::>:<:: ::.:>::: >:<: >::<: >»: >::- ::::>D ..............................:. �::::.:.................. ................:.............. .. ..�.. - 4. i' '�i m:* x:::: n •. •. ..•yw. � v. �...; . r.....: • • �i .: ..... :....: :...::• � S:i'i 9ii< ?ti•:•.i;:;. •: ii:3. <;::: • :::::: :: .:. ;: .:: :•: . 112 ,jA�,��iij ' X XV- cc 1 - 6 WVII J� ":'1°'i , tr - ' fi r ( >11 l igC - 0 10t) -- 3bIo6 rilkig ' g 'ti1;` mg );.;:, et - Allwier, r. .i P , \ C I* , \ ' I � 3/4 , I# 1% t -- 1 L r ---1, , r il , I 0 1 3 71 1rY B B ! , 3 " j ll� F� / TYP 1 0 Loe a 1 I — 1 k TYP F— -- ! t : ---- t= 0.07" J 8 i =.09" / I J _ 1. / _, # - 1 $ J �� I ml +-1, i I �I J — I II I 96 BEAM 1= B EAM I� ' 1 [ * ; t I __ -`I2 ? / "0 RIVET - / ASTM A354 -79 TH'K= 3/16 " - 7/16 " 0 RIVET I ASTM A354 -79 TH'K= 3/16 / BRACE TO COLUMN CONN. ( 2 PIN CONN. (2, 4 PIN CONN. ( COLUMN SECTION (47 BEAM SECTION (51 i I FILE COPY I understand that the Plan Check approvals are ,- / 1° I subject to errors and omissions and approval of / � I` I ? plans does not authorize tfie violation of any ( JO ! �j ° ? tracpors copy of approved pl n s acknowledged I ' Ir � B f 110, a Date l o f7C9 2 — � � . �� I► I Io 1702 It.3 I v O i i , \\ Permit No. i . . 1 Oi j� i I° I , a 1 11 ,/ �,, >> ,. — /fit �� �A % i ` , 3 r // v \ i = ,J \\ frk °I_ =.36 KS;_ Of NOMA (AST,,, A -3.'.; qrf : a �o o oa�vc�� stoma. e MADE �o �\ \ °. °iii_ 5S. ®PE of EA° WIT HOUT F } \ a Q , z TUIMII6A BUILDING ., ' - 8 2 002 U \ c ��v� o� DIVISION. MAY � \\ ° 4 F"1'1 ^'!5 MILL n O ItAE A NfW PIAN El'9 tJI a . I` , lBL i BASE PLATE DETAIL (6; BASE PL. & SLAB CONNECTION (7; GENERAL CONFIGURATION (8; (9; 10 12)(2)) a ssoR I 1,5 SP 1 44" 42 ^ ' r------' I _ 4 4 1! v / a rYF' I g ; NOTES: 1- DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AP O o arr 9 ,4¢- '� EVEL 144" BEAMS OF THE L UNIFORM BUILDING CODE 1997 EDIITIONHE REQUIREMENTS , � S S ONAI.E�GA� CARL'. 3' ``. 2- STEEL FOR ALL SHAPES FY =50 KSI. ASTM A570 -85 GR.50 (EXCEPT AS NOTED) APR 3 0 2002 3 -ALL WELDED CONSTRUCTION IN A SHOP OF AN APPROVED FABRICATOR EXPIRES 12 -31 -02 I I - \- - a (E70XX ELECTRODES) I PERMITCENTER 4 -WEDGE ANCHORS HILTI KWIK -II ICBO #4627 OR RAMSET R.H. ICBO #1372 Tv P. (NO SPECIAL INSPECTION REQUIRED) 5- CONCRETE SLAB 5" THICK 2000 PSI. SOIL BEARING CAPACITY 1000 PSF 6- STORAGE RACK CAPACITY 2000 # /LEVEL B 96" , 3000 # /LEVEL W 144:" BEAMS A 7 -ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS rn _ A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA REV. DATE REVISION SHOWING MAXIMUM PERMISSIBLE UNIT LOAD NOTE NO. 6 RACK DESIGN AND ENGINEERING - .6: TYP . 8-STORAGE RACKS S KS SHALL ALL B B IN E INSTALLED WITH . ", r4XI XIMUM TOLERANCE FROM THE VERTICAL of 1" IN 10' - 0" OF HEIGHT 3786 LA CRESCENTA AVE. #204 GLENDALE CA. 91208 _ SCALE: NONE DRAWN BY. A.KH. DATE 4 -15 -02 PROJECT: O fM NI FITNESS . 1171 ANDOVER PARK WEST, TUKWILA, WA. FRONT VIEW SIDE VIEW STORAGE RACK DETAILS JOB No. ISHEET NO. RD-6751 i OF 1