HomeMy WebLinkAboutPermit D02-190 - CENTERPLEX D - PARTITION WALLSCENTERPLEX D
320 ANDOVER PK E
D02 -190
_ . 7�i -" .,
1
I
,.....) ,...
At�,�
4 k},�' ., City of Tukwila
f1
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
1 DEVELOPMENT PERMIT
i z
Parcel No.: 0223200060 Permit Number: D02 -190 ' .�
Address: 320 ANDOVER PK E TUKW Issue Date: 07/19/2002 Q I
Suite No: Permit Expires On: 01/15/2003 J 0 '
U) Q
Tenant: vO W
Name: CENTERPLEX D J i
Address: 320 ANDOVER PK E, TUKWILA, WA N o .
W
Owner: 2
Name: CENTERPLEX Phone: g Q
Address: 331 ANDOVER PARK EAST #100, TUKWILA WA W d
W
Contact Person: Z H
Name: RON NICHOLES Phone: 206 - 575 -1018 H O
Address: 331 ANDOVER PK E, TUKWILA, WA Z t—
W
Contractor: U 0
Name: EMERSON CONSTRUCTION INC Phone: 0 2 .
Address: PO BOX 78517, SEATTLE, WA
Contractor License No: EMERSCI995D6 Expiration Date: 04/05/2004 Z U
H
DESCRIPTION OF WORK: IL
INSTALL TWO PARTITION WALLS 5'X9' AND 21' X 9' USING 4" METAL STUDS ON 24" CENTERS. DRYWALL TAPED & U Cu z .
FINISHED PRIMED AND PAINTED. H F
O •
Z
Value of Construction: $2,400.00 Fees Collected: $141.86
Type of Fire Protection: SPRINKLERS /AFA Uniform Building Code Edition: 1997
Type of Construction: Occupancy per UBC: 0016
s
Public Works Activities: :
Curb Cut/Access /Sidewalk/CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0 •
i Flood Control Zone: N
Hauling: N Start Time: End Time:
Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. ;. ;;::.3
Landscape Irrigation: N .11111
j Moving Oversize Load: N Start Time: End Time: , ° `, ,
Sanitary Side Sewer: N '
Sewer Main Extension: N Private: N Public: N y�'_
Storm Drainage: N •
Street Use: N z ,.rI n
Water Main Extension: N Private: N Public: N i =;
Water Meter: ' j
Channelization / Striping: i ''
** Continued Next Page ** , "' '
doc: Devperm D02 -190 Printed: 07 -19 -2002 "°`
. . ': i `:,,. ,...,. •.: }...; ..,:,. ., .. .. ...,: ?:::: ... i. ,_ ...... .>>,. �f: 6 ,, :1k.:.C,:_....va.7:L<. -y.... .!•'Sr »... .,.fi:v- rza.ivL .Jip±Sfl' /w- ++mYnMN^.. ... .. .. .... ...`r..,.... ... .,... »..,.....w...uw..— .....r. wr.+rw.. a.w.H:r
i
'
-- �■r • - , -_,
•
•
t "! i�+ C ity of Tukw i l a • •
1908
Department of Community Development / 6300 Southcenter BL, Suite 1001 Tukwila, WA 98188 I (206) 431 -3670
,
Permit Center Authorized Signature: -ve1� ~ -,e—L Date: 7 / OZ ' ,
'
,
1 ,
! V'41471
doc: Devperm D02 -190 Printed: 07 -19 -2002 l '':;; „r ,,�, :i lY
,, �_�.,...,.._....,._..... ,..._._..,...,,...�,:.........- - - .,..,,.s. n wa.e. — . . ,.__ ......_ ._...,.....,. ..........,.,..,w,......._...�. - __..,w ....n. _.... ... ,,,, .rmiiwMOrM
i .
r
� Cit of Tukwila
Me f Y
loo
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS z
, 1z
Parcel No.: 0223200060 Permit Number: D02 -190 ' ce ¢¢
ur
Address: 320 ANDOVER PK E TUKW Status: ISSUED J v
Suite No: Applied Date: 07/02/2002 U O
Tenant: CENTERPLEX D Issue Date: 07/19/2002 . N W
J 1.—
N LL
1: ** *BUILDING DEPARTMENT * ** • ' W O
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2
3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be g5
inspected by that agency u.
(206- 835 - 1111). N = d
W
4: All mechanical work shall be under separate permit issued by the City of Tukwila. . f- _
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These Z
documents are to be Z O
0
{ maintained and available until final inspection approval is granted. LU ul
6: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. D ❑
i 7: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 0 w
8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as 0 H
amended, Uniform Mechanical Code = W
(1997 Edition), and Washington State Energy Code (1997 Edition). I— F
9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a u. Z
permit for, or an approval W
of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to U
give authority to violate 0 I •
or cancel the provisions of this code shall be valid. Z
10: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code
and the Washington State
Ventilation and Indoor Quality Code, Chapter 51 -13 WAC.
11: ** *FIRE DEPARTMENT CONDITIONS * ** l
12: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: .
13: Maintain fire extinguisher coverage throughout.
14: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) .
15: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be
locked, chained, bolted,
barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3)
16: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged
from inside the tenant
' space. (UFC 1207.3)`'
17: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel t T "` 6. `'`
shall also comply with . r1 . ,
the Building Code requirements for accessibility. (UFC 1204.1) ` Is.
18: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or i! �r"
4* aTk_
adding sprinkler heads. '
19: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of
;.�
drawings prior to installation ry r
or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written ',
approval the W.S.R.B. ` 4 'c ' f
Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior y r
. r;
to submittal to the v .. , ,,
,- t,
doc: Conditions D02 -190 Printed: 07 -19 -2002
y s.: j(. _ .r,.. r :"ir • KZt , 7::4YR.lrti +- 4`x'3 °urt]'.iY,Y+K'V^r7'"+ti nvs+.ww,�v.n.a..nr r ...,.„........4..
.
r - , . .
•
a *1 !Y-'. %' CITY OF T(LKWILA . , FOR STAFF USE ONLY
- y� ` o Permit Center Project Number:
'r ta / = 6 300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 �0 1 Ol D
. " fibe 206 ) 431 -3670 Permit Number:
Commercial I Multi - Family Tenant Improvement / Alteration Permit Application
Application and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
Project Name/Tenant: Value of Constructioak
CAii'�,P PI, 6',lf 3 (X , 4/d,9 " 0
Site Address: City State /Zip Tax Parcel Number: ,.
320 Av..do✓6,e /31, ik: 6 r T" A. 4 i / r ,, y _
Property Owner: Phon
. C7 /T ?/ 6 - ,57....c.: /0 If
Street Address: City State /Zip: Fax #:
38/ AA1.0/6 2 PARR EAS-r. fl/4M4 k /.4 c / /X T -77o f 20 -57J /029
Contractor: Phone:
- 7 - a 73e c -r T
Street Address: City State /Zip: Fax #:
Architect: / � � Phone:
i( I
Street Address: City State /Zip: Fax #:
Engineer: Phone:
/(JO/J
Street Address: City State /Zip: Fax #: . Z
Contact Person:-7") Phone
~ W
1�O, / (7-/1 , XC j i : / 0/ 3 c
Street Address: .. City State /Zip: Fax #: J U
- :f A /ic1i' % -f ' / , 4/'/ i klr /// f,r.II , i- I, . q, , -�, , / ( :: 7J_ /, - 0 0
0
Description of work to be done: , r, jST L L Tk,J0 1)/412 -TI •rl GA) 144 1.1..S 5 x.? A,fJa z/ q ' us / ��- u) w
J F-
ME STuas opt '` u 2s -D/2..V CE TE c4�.z . TA $ F'1 Li ? �u. Eb Arab 1 • xi W o
TAL
Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital 2
Church 0 Manufacturing ❑ Motel /Hotel a Office LL, Q
❑ School /College /University ❑ Other (0 a
Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family
= ❑ w Warehouse ❑ Hospital I-- _
Z F.
❑ Church ❑ Manufacturing ❑ Motel /Hotel .53 Office H O
❑ School /College /University El Other w I'-
w
Will there be a change of use? ❑ yes gi no If yes, extent of change: (Attach additional sheet if necessary) D p
U
Will there be rack storage? ❑ yes .® no 0 I--
W —
Existing fire protection features: ® sprinklers ® automatic fire alarm 71 none ❑ other (specify) M U
_ � I-
Building Square Feet: v2 6, C 2 5 existing Area of Construction: (sq. ft.) i ' 7 O` 1'+ 2- u- z
ti-i
Will there be storage of flammable /combustible hazardous material in the building? ❑ yes gl no U
Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ~ O F-
z
APPLICANT R FOR PUBLIC WORKS SITE/CIVILPLAN REVIEW OF THE FOLLOWING
• .(Additional reViews-may be determined by:the Public Works Department)
❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling
❑ Fire Loop /Hydrant (main to vault) #:____ __ Size(s):
❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. Li Landscape Irrigation
❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public
❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public
❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only
❑ Water Meter /Permanent # Size(s):
❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule:
❑ Miscellaneous t '.
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and
!L
is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by / '
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by
the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
Date application accepted: Date application expires: Application taken by: (Initials)
? - 2 -0 2 1 2 - 0 3 J"C-; r ij
.
PLEASE SIGN BACK OF APPLICATION FORM ��
R mj
CTPERMIT.DOC 1/29/97 t'. i
.rdlla sal
•e
ALL COMMERCIAUMULTI -FA TENANT IMPROVEMENT /ALT= TION PERMIT APPLICATIONS
MUS : E SUBMITTED WITH THE FOLLO ' NG:
➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT,
STRUCTURAL ENGINEER OR CIVIL ENGINEER
> ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
• BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
N/A SUBMITTED
❑ Complete Legal Description
❑ in Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures
(Form H -13). Business Declaration required (Form H -10).
Four (4) sets of working drawings (five(5) sets for structural work), which include :
❑ ❑ Site Plan (including existing fire hydrant location(s)
1. North arrow and scale
2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements
3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions
4. Location of driveways, parking, loading & service areas
5. Recycle collection location and area calculations (change of use only)
' 6. Location and screening of outdoor storage (change of use only)
7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's
boundaries
8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of z
use only) <
9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of z
those, identify by size and species which are to be removed and saved w g
10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change 6 v
of use only) 0 0
11. Location and gross floor area of existing structure with dimensions and setback w
12. Lowest finished floor elevation (if in flood control zone) w
13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- N u_
9) w O
❑
■\'1 Floor plan: show location of tenant space with proposed use of each room labeled
¢
❑ M Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of d
any hazardous materials; dimensions of proposed tenant space.
❑
K1 Vicinity Map showing location of site z
t--
z
❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack w
layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of
rack. Structural calculations are required for rack storage eight feet and over. p -
i-
❑ Indicate proposed construction of tenant space or addition and walls being demolished w w
❑
11.1 Construction details H
O
❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of w z
water supply to sprinkler vault with documentation from contractor stating supply line will meet or U
exceed sprinkler system design criteria as identified by the Fire Department. p I
z
❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings.
❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds).
❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other
land use or SEPA decisions.
❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County
Department of Public Health prior to submitting for building permit application. The Department of
Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5)
❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no
contractor has been selected at time of application a copy of this license will be required before the
permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and,
obtain the permit will be required as part of this submittal . �, t t
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
AM al
BUILDIN NE - ••.: AUT. • • ' E %AGENT: _
Signature:
N(i 4.10: • Dater ` j. l � D 2 , ' al
Print name. 1 Pho ne:���;_rr% -�n� Fag �t �1 r. — /02
mn na �n o O -� 5
Address S n q 1Oy 3 1 AvyA0 ll �l� C e i`c4. E - - 140 City /State /Zip -rt�1 VVI 1 11 . i a)3 � '� �►,
'
CTPERMIT.DOC 1 /29/97 L.
fY T, 7 imlt9'mJt ��t1Ri 'I , yr ii n s^ .o.vsrr._ i*N• #a;a 'i+.xJ. ^rtlt�i'' �sg v- v-- ,tyv�•� 9sv. wtiS'v s1'.Y•s a}:6:v. >Yr;{ e.^,o?v; ".
........ ..... x�i�' M?IIB�$' 'hMFJ�'X°3ftRYY�fi� K� "�' SC �" � !�+•ttfinY%ig %r". �' i�" R. +fei
+ • I
, - -- . .
. '
,
``■
z
< .
p
ce 2
1 . ; ,....,) / --Th 1
. . i , . , .
0 0
S '• INSPECTION RECORD. D7) ,... /70 116 , 0 p
Retain a copy with permit 111 i
-J
INSPECTION NO.
/ P/MIT NO.
4'
ui 0
CITY OF TUKWILA BUILDING DIVISION •,.. ,4)
•/. , 2
6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431-3670
g :-1
IL
I e X; oject: y pje.t. D Type oclnspection: ,
J D
r pia (12 a
z
Mdr 0 ess: v6.- e F _j ' , Date alef , , 1.- Ili
g trrrk f
.,... : i
z,._
Special instructions: Date w?3te : 0,57 CII_____n2, ‘;
.
-- —
I- 0
(1 r VA/f)q
Reques)9 p.m.
LIJ uj
2 D
/1 / D CI
(..)
Ph 0 u - 2
pproved per applicable codes. ri Corrections required prior to approval. , X o
I—
• F-
,,, 1 2.r. 0
COMMENTS: ,
Z
w CO
0 . . . . .
D
0 •
_
47kr‘An14 i dm p i-to ---t, , „.
‘
...
N., .t., .
.
. R. r
/ ' OP . f . -P 4 q,;•
1 ,,, . •"' '
I nspecto .
r
• sY7A- . . 9,. 02
Date
-
0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. •, ..
Receipt No Date:
s vir,i7*.mr.,:g
- . ' 7riir•
/....,:,:, '
, ,...,,,,,,4,44,,,,,,„i„,„,,K,;,„41,„4,.,:,,,_,,,,,,-„:,,004.1,......,..,.,.,..,,,,,,,,,....-„..e...a:,
(
i
..
. - -..e_r ....,,
N .
,.. •
)
Z
I—
w
• :
r) .
... __. 0
O 0
.. :
• w 0
INSPECTION RECORD 4. 7/90 1 u) w
w i
--I 1-
Retain a copy with permit,
1
w
,„. I,
INSPECTION NO. / ,/ _PERMIT NO. ■
w - - ;. - ' .4
CITY OF TUKWILA BUILDING DIVISION t * 41 2
:,-. ▪ ,
6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 g 7J
...',<., u. <
Project: i Type-of Inspection: W
— 0
4 e
le,lr X ]-4. D r /,...-/ -
Address: / ,._ Date.,c4Iledi,,-/ . I
..‘,.‘: 390 112-,cover Pg L- / 7/ -...,,, }
1.- o
, 4.... *, Special instructions: Date wfijer
, C.m.)
i ', ? 6',. p.m! IL ai
2 D
Requestyr: D 0
1
fC 01 0 U)
0 —
1..; Phone:
) -5 75 Jo/f
.:-' I 0
1--% , Approved per applicable codes. 0 Corrections required prior to approval.
'',... COMMENTS: ai Z
4 ,'
V-
. ? F''' ' I 9,,A.-1_, n .(9-/) 1).2 _c ce..9 --‘,.....-3 _ o - •
.,1.--.>. z
,
x3, -,4--,. ,
A ,
'.. e-v(\ 13 J\ e ) s 0
/ c - a - A. ,Ai 0,
,.., .
' .
- a ../) ril 3' t
'.1;
■..) .
'-(-7-: (
(ig) Q r.
7v 0 A, ) Ct.., Sl (,... G je,...„ ,
...„-.
4
• .-' ' "--- CV- T4 IN A. "1-41::e)
:,... ,
-.:
....,, „
/r
7
,1131 ix,d2.,
....,.
..'''
...:' ' NN., ' . 4 c4 ,
.
1. 4 4 : ;7 -44rIti
.: In-•ec •r: Date:
4 _ 0 .,... .-*
_IP - .............f. . ... 40 - . W; I
- - .. ...... - '
T: - . .
, . '
' Ei •" 1 0 REINSPECTION FEE 'EQUIRED. Prior o inspection, fee must be paid .•;1',.s;Mt'''.
: •:00 Southcenter Blvd., Suite 100. Call to s hedule reins•ection.
Recel No: Date:
.
,A,,,, , - - ,., , ," • : - , , .1 :r. , % r ,■)''.( :' "I' .., ''',..''' I ''''', `.; ''" ' ' • ' • -. ' .1'4,42 :•q 1-1.. - Lyss
', • ■ . . -- ,- 4 -., -..,, I 4, .4 n ---,.... k•- .47 W. ••••• ••••• • .. • • • ., • A • V144 t ii • ic • • .•';', •:41 •••-•i• I, Z.,r+ ' 4 d 4 444
■ ,
4
, H.
--- ( •
,
s• ,
. •
'
...
Z
< •
s i
).- z
Ili
rt 2
.
-.47 ' ' ! .;'1'4. • ' '. . ' ''''' - .: ' ''' ..!'.*' .' ''''•''' • ' i • ' ': ■ ' ' ': . ''' , • ' * • ' '''• ' • ■, '' ' ••, ''' ,„.54 Vin isi rai..?4ii:+' ;:
,
- -k 4r —
■ - ---
r
s!
. •
..
\. 1
•
Z
< , •
' ,/•• Z
re 2
1 m .
...
't
, , \
‘
_1 0
t :
(
0 0 0
' '':*". ' . • '... CO Iii
V ■ I
1 INSPECTION RECORD - p 140 \ w
I 1--
Retain a copy with permit ' ' co u_
4(
Lu 0
•,,,. " INSPECTION NO p i PERMIT NO
CITY OF TUKWILA BUILDING DIVISION • 4 I 10
6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431-3670 u..
(f)
6 ,pbP _ reR /)L/ /..)/09 Tyrf Inspection: — C5
F ui
..ki4
i
Z 1--
Date call :
''t ,12-0 1 i
Ps.
7 2 to 0
...,,- :: Special instructions5 Date . 13 9 7 , a.m. 11.1 uj
---___.-
''->f .. • bi7e) - 1170 Requpster: o
,i--'4./ /i/ex-/A7
tir.i
:: '
,
.
4..: :.•: ••i_■:___6_)e=7)-,..S----f/7.7
I 0
''''
I-- r -
-i:::-
c:11::, . [I] Approved per applicable codes. XCorrections required prior to approval. — 0
. e ' •
I ' COMMENTS:
— x ,
1. 1 rovirlivI9 r 0 veven WI-4k , Z
N
IX' '
1 1,11 r\T\i fQCAYI 1 k V1 cre
,
.2..) (.A) \rac , .e. y\c)--\ i $ ( I ect
( 5-t.'e--- r\-c16.■\ nvn cloehrokfeel
;i. c4v1 (-2) i
'' ' .' • 3 ) t 147C4 If x cle■ pf:, V VteN `‘ i
, Ci ef Y n% i A r Li red ,
1 .
, ... . , .
.,.
1
.
Mer St
::,
,,,
• .':,• • . Inspector: .° .."----- Date:
'. — 02
A , -
. ,
0 $ '
47 00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r.lp
i.,., - Receipt No: Date: pit,30.4,
A
, -
U
,....;
41.4 '..% 1: ''' ,43 : b M , ''' 41144 • 1 '::' ,..::. f''.::' : I I44 `"'-' ..;. ` 4:44 ''''''''' ; '':'':' '''''': " '''' • '.:"..'., , r ,1,,, ' , ;.- 1. t 4 sir, , -1-.( , -5i.:ra ;O :..A. :' '"A3 Ii'it ,,, i1fgde 'WA' At 1 ' . : , ' e 0,Alti
....
i .
1 ,
, ___ t , a — - — _. . —,
,
.. 0
... - *
....
•
. z •
. 1
r‘ 2
.'',.: ..........,..i....i.,
■ .
,
, , - - - - - r- _
■
..t 75 ;, .. :,C\,c A71,77\--‘.. q+"+R',*i�- N•+:i4 Fr- n- ,*.�* 1 +' a" „ 1 .r�^� +�.,-- �+,+, —'-^ -- -
��� of '��" iYt � \.i -� .���� 7 ::�: ,/ "� ii�` h' i ��� "� ftt'�,. 7 Ni ti �r £� 4
- �•C•e�'T� ,.. �r -!��
t a i.
WILA tv
oi z' City o ' �; of Tukwila Steven M. Mullet, Mayor
+.III - .!" _--1
, to r ` + i Q Fire a ' 2 , Fire Department Thomas P. Keefe, Fire Chief
1908 ---
/ 90 z
~ w
TUKWILA FIRE DEPARTMENT J U
• FINAL APPROVAL FORM 0
co 0
w =
—i I—
. Permit No. N O
W �
J
• Q
w
= a
H
Project Name ( _ .I .�, ^ l
7F . --'t t P ! : Z
" w W
Address .a • "��'� S uite #. 2 D
• cn
O H
-... . . .... Retain .current :. inspection schedule
Ili U
LI 0
Needs shift inspection ,
w
c.)
V 0E- •
Approved w correction notice z
Approved with correction notice issued
Sprinklers:
Fire Alarm: ! "•'A ,cl. F l)
. Hood & Duct: /•,/
Halon : n I
Monitor: x:/er. ,S c/. 6A...4 . tC_rfii? /t\
Pre -Fire: tt .
Permits: 5 : '.,..: : ::.
, 'r 1
:.
a m ,:
f # 4 I
.�ft_.Fs +�� r . r �
,=.7-.7--- , ,
c- n) inn
----.:1- , zet/c.Zi., . , (....... (...../,,,,...., 4'4_, ,,,n,
Authorized Signature , , `��• "'
FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 <; ;
,, , 1 :;; , 1 , 04
CM 4•
{
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439
. .s .. ..... .. ... ..._.,ta �.. u.:.�. +.. _:•1t_..�3... ,........a,..i.,..,..,.+t v. a,..w.�v.r.:,:..N.,wis:xi"y.r . , i. •. ,. .... , i a, ,,, w+ i. ivwe,.+ uiu+.:;. v .;a.+:.+J.c.. »::nv,e.t',r.d.u:m w.:u.o:..:�ad+iu kit,.i ,. x_....V..:.l..::.. —_ ...
__ _____ __
Cr4
°-1
tli j.•
5 ii__
el)
5 . • •
it 1:::, t:::,
omi pl O
11: w
4 .
O
= :::4'..' N,
; cra 0 , _ _ _
_ ,
` : ; NOTIC E: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN
r 7 % H QUALITY OF THE DOCUMENT- ,y t t t ' I THIS NOTICE IT IS DUE TO
$`. ..- :yam._ u,.= -'.
-
_ A
I ' - i • _ _ _\-.• r
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D02 - 190 DATE: 07 -02 -02
PROJECT NAME: Centerplex D z
SITE ADDRESS: 320 Andover Park East m w
k . Original Plan Submittal Response to Incomplete Letter # v o
I U) al
Response to Correction Letter # Revision # After Permit Is Issued w H
CO W
WO
DEPARTMENTS: g a
IS _t 1 �'�' �!Z Zoo OP c. u.
Buil Ing Division • Fire Pre ention ' ' Planning Division • n
.,
j 1' H W
Public Works Structural Permit Coordinator 4 z i
z l--
w al
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -09 -02 2
D CI
—�/ O Y
Complete V Incomplete n Not Applicable 0
W W
= U
F-
Comments: LL �
O
W z
Permit Center Use Only H 2
O (-
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: z
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
1
TUES /THURS ROUTING:
Please Route yr Structural Review Required ❑ No further Review Required n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 05-06-02
Approved Approved with Conditions Not Approved (attach comments) ❑ ' ,
,,, , , F
Notation: . � i
REVIEWER'S INITIALS: DATE: �j I.JT2
KS. *. .
Permit Center Use Only t
tai �^ 9
CORRECTION LETTER MAILED: .. ;
; , ' P ' J ±
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: u} "�' ,
V` ,
Documents/routing sllp.doc
2-28-02 e ` 3t�� v • .
+ v��Y- Hnlnoia+.vw�ae,�s/.AVJY.4P.V H�. i�U» r. FYevY: m�Mhl' n. M" ri" YJJ..•* JJ •.f.xryµ�K'ki.W'Nhk'!�!1•KY.H�
.T.:' .. f :;l ..,. ,. .,. ..':;N t i , ..:+N , �.`.y!4fuN:.,S'::e'va arrua:�i.'fn.:vi+.im.xe. i:.r, .: .W . �. nna,+ eew arsa. �n: rf.• .•ef +..ss.»...,•�...e.wr..w�mes — ,.eavH..,.f.,�. \
■- t - — , ,,,
PROJECT NAME: Centerplex D z
w
SITE ADDRESS: 320 Andover Park East W
x Original Plan Submittal Response to Incomplete Letter # N o
cow
' Response to Correction Letter # Revision # After Permit Is Issued H
.
"t.ir �,
N
,. 1
---
PERMIT NO.:t2 1 TENANT NAME: Ce 1 1
-v e,_ b
P 1 e
BUILDING PERMITS
INSPECTIONS CONDITIONS ,
❑ 1 Progress Inspection Status f* 10001 No changes will be made to the plans unless approved
f ❑ 2 Pre - construction by the Engineer and the Tukwila Building Division
❑ 3 Investigation ❑ 10002 Plumbing permits shall be obtained through King Co Z
❑ 4 OK to Occupy 10003 Electrical permits obtained through L & I =
❑ 5 Remove Stop Work Order 10004 All mechanical work shall be under separate permit t— Z
❑ 6 Follow -up 10005 All permits, insp records & approved plans available re g
❑ 7 Pre -Move Inspection 10006 All structural concrete shall be special inspected 6 n ,
❑ 50 WSEC Residential ❑ 10007 All structural welding shall be done by WABO certified U O
❑ 60 WA Ventilation/Indoor AQC inspector 0
10008 All high-strength N
❑ 70 NLEA Inspection /Modular Struct ❑ gh- strength bolting shall be special inspected U) =
❑ 71 Mobile Home Tie Down Insp ❑ 10009 Bolts installed in concrete shall be special inspected J I
❑ 7 Marriage Lines ❑ 10010 When special inspection is required...notify Tukwila U)
❑ 90 Resteel Building Division w 0
❑ 95 Footing Drains ❑ 1001 1 The special inspector shall submit a final signed report 2
' ❑ 100 Foundation Footings 10012 Any new ceiling grid and light fixture installation
0 200 Foundation Walls 10013 Partition walls attached to ceiling grid ti. <
❑ 250 Foundation Insulation 10014 Readily accessible access to roof mounted equipment U) d
❑ 300 Concrete Slab /Slab Insulation ❑ 10015 Engineered truss drawings & calcs shall be on site I
❑ 350 Crawl Space ❑ 10016 Any exposed insulation backing material shall have _
10017 Sub grade preparation including drainage, H
❑ 400 Shear Wall Nailing ❑ g P P g f; . excavation Z
❑ 450 Plywood Wall Sheathing ❑ 10018 A statement from the roofing contractor verifying tire z 0
❑ 500 • Roof Sheathing Nailing retardant class of roof w
❑ 525 Plywood Deck Nailing 10019 All construction to be done in conformance w /approved j O
❑ 550 Exterior Wall Sheathing plans U
❑ 600 Masonry Chimney 0 EL)
610 Chimney Installation/All Types ❑ 10020 Structural observation shall be provided for this project 0 I-
700 Framing ❑ 10021 All food preparation establishments must have King Co = W
j 750 Roof /Ceiling Insulation ❑ 10022 Fire retardant treated wood shall have flame spread of I— U
❑ 800 Floor Insulation ❑ 10023 Notify Building Division prior to placing any concrete LL. 0
❑ 801 Wall Insulation ❑ 10024 All spray applied fireproofing shall be special inspected Z
❑ 802 Exterior Roof Insulation ❑ 10025 All wood to remain in placed concrete shall be treated Ill U)
' ❑ 803 Glazing Inspection ❑ 10026 All structural masonry shall be special inspected
0 z '
❑ 815 Lighting and Controls ali 10027 Validity of Permit 0 I •
900 Suspended Ceiling ❑ 10028 Rack storage requires separate permit Z
1000 Interior Wallboard Fastening
1001 Exterior Wallboard Fastening ❑ 10030 No occupancy of building until final insp by Bldg Div
❑ 1 110 Pre -Move Inspection ❑ 1003 I Comply with requirements of TIM 16.04
❑ 1 I l5 Motor Inspection ❑ 10032 Remove all weeds, concrete, stone foundations, flat ‘
j ❑ 1120 Pre -Demo concrete
❑ 1140 Pre - reroof ❑ 10034 Removal of septic tanks require approval and
1400 Final -Fire compliance with King Co Health Dept.
1700 Final- Building ❑ 10035 Contact PW Div to obtain insp for water /sewer connect .
1900 Final - Reroof ❑ 10036 Manufacturers installation instructions required on site
❑ 3100 Site Visit
❑ 4000 Special - Concrete ❑ 10038 A C of O will be required for this permit
❑ 4001 Special -Bolts in Concrete ❑ 10039 Final approval for all TI w /in the limits of the SC Mall
❑ 4001 Special - Mom/Resist Conc Frame
❑ 4003 Special -Reinf Steel Prestress i 10040 All constriction noise to be in compliance with 8.2 TMC
❑ 4004 Special - Welding 10041 Ventilation is required for all new rooms & spaces + +' fl
❑ 4005 Special- High - Strength Bolting !q
❑ 4006 Special- Structural Masonry ❑ 1004 Fuel burning appliances • , ii i4.0, ,1 i,
❑ 4007 Special -Reinf Gypsum Concrete ❑ 10043 Appliances, which generate 4 008 Special-Insulating '!!,
❑ P g Conc Fill ❑ heater s 10044 Water heathall be anchored a kri
sf .,
❑ 4009 Special -Spray Fireproofing ❑ 10045 Reroof ' —f-''A
❑ 4010 Special - Piling, Piers, Caissons ❑ "Anchoring — All new construct and substantial Pi ° ❑ 401 1 Special - Shotcrete improvement shall be anchored to revent flotation" Excav /Fill
❑ 401 Special-Grading, r
❑ 4013 Special- Retaining Wall y� " x - ,,,
Plan Reviewer Date: ''') Lj f/ ��
❑ 4014 Special - Panels ( {J f,i, t '�'!' .
❑ 4015 Special -Smoke Control System
1/4 i3
"�'•_ "4
ti
Permit Tech: Date:
1-1 O2 "
fu ,1
"',s....
,mrra.!erbs!
tfz... , .. y •:, z ' s' *. w•: .o• • x s�'x:....... ....... uw..,... -... ... u ..+..,..,•.,.,. , «.,,. ....,..._., .„ . , . .. .............. ......... ... w , .+�, ..µ,pr N�".:v1iR•hSek -al-t . ..., J ?EdSN1iR•i4`:
{
.
t
, ::
.,.4..
{
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D02 -190 DATE: 07 -02 -02
PROJECT NAME: Centerplex D Z
1- z
SITE ADDRESS: 320 Andover Park East rej
. \ .i
- •
j r ,
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D02 -190 DATE: 07 -02 -02
PROJECT NAME: Centerplex D a
mi-
,I- w
SITE ADDRESS: 320 Andover Park East re
X Original Plan Submittal Response to Incomplete Letter # N o
` w
■
Response to Correction Letter # Revision # After Permit Is Issued _I I
1 O
i DEPARTMENTS: g5
u.¢
Building Division n Fire Prevention I . I Planning Division fa. u = w
I ' H
P Works Structural Permit Coordinator ? I
E-
LL/ Lu
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07-09-02 v o
o�
n
Complete "� Incomplete n Not Applicable W u
=V
! Comments: 1--
f :.
u.. p
ui�
0 -
Permit Center Use Only F- H
•
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: z
Departments determined incomplete: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING: ‘ -
i
Please Route Structural Review Required n No further Review Required
REVIEWER'S INITIALS: 1‘ DATE: 1 /ioa
APPROVALS OR CORRECTIONS: DUE DATE: 08-06-02
r t
Approved U Approved with Conditions — Not Approved (attach comments) ,t, "`
, Y "y y ! .F
i Notation: A "�:t
REVIEWER'S INITIALS: DATE: {
a
Permit Center Use Only
CORRECTION LETTER MAILED: Er.
7
��
Departments issued corrections: Bldg El Fire ❑ Ping 0 PW ❑ Staff Initials: p .,r
Documents/routing slip.doc
2.28 -02 S - ..4"'
tt
. t. w .. •... ., u. .. . . . ... .. .«.«...w.,.a.......... ...n 1fN #W'1(ikn NUifroVl4WCItFaFXV.�'BTJ.4M.
•
''1
---- ,
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D02 - 190 DATE: 07 - -
PROJECT NAME: Centerplex D z
SITE ADDRESS: 320 Andover Park East .1- z
K Original Plan Submittal Response to Incomplete Letter # d O
g p p o
CD Response to Correction Letter # Revision # After Permit Is Issued s
{ - WO
DEPARTMENTS: 2
u.. cc
Building Division n Fire Prevention Planning Division cry a
Public Works )( Structural n Permit Coordinator n Z ILI
F- o
Z F-
LU W
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07-09-02 v o
Complete n Incomplete n Not Applicable n o F-
WW
Comments: H H
IL. O
w
Permit Center Use Only U =
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: 0 ~ •
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING: \ 64Vr
Please Route n Structural Review Required n No further Review Required '
REVIEWER'S INITIALS: O/dYY\ DATE: 1/3/02 .
'
APPROVALS OR CORRECTIONS: DUE DATE: 08-06-02
Approved n Approved with Conditions n Not Approved (attach comments) o. - k
^ .
.
,'
Notation: 1;k "'
f i��. J lk '4
REVIEWER'S INITIALS: DATE: t, "+'�',}
Permit Center Use Only , ,
,,
CORRECTION LETTER MAILED: 451?d
,
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 044414 n r}
Documents/routing slip.doc ° b
2.28.02 "r wt o
_
'7/16/2002 08:46 FAX 2067721899 E.0 I __ 02
r ---- -- Detach And Display Certificate ----,
DEPARTMENT OF LABOR AND INDUSTRIES
i
REGISTERED AS PROVIDED BY LAW AS -
I CONST..,. CONT GENERAL ;
• '.;A[EISdC::,;•t7:, DA _
. 1 .cc01 ' . ' IDIERSCr995D6 '04/05/2004 . '
Z ..
' . EEFEG�LVE DATE 7 03/26/2001 W
. I ; ..r', T ., ";.1....ft...,'..'. •: • , 4 7
I EMERSON•:CONSTRUCTION 'INC .. V U O
PO"BOX '.78517 • - . • •
• SEATTLE':WA , 98178 ' • ' ' . .
CDW
I J =
H
•
?S 052 000 ta197) CO u_ t
al
' Detach And Display Certificate — 2
_ Cl '
. F•- _
Z ~
ZO O .
W uj
7 0
C.) CO
,0 F-
LU W .
IL P.:
. Z
O F" '
Z
•
•
�.
... ,', - ��
n
:f: zl,.�r3,S14. -
'. 7,9- �5 s
r r `. •` .•5 t
l r
. :. ,. ..... ..• ... '. ,. . <._,,.,...o.:L...,.t.Je..a. .r, ...,,L2;J: +_._...,�...w .,.....•_..., ----,. +............ ... ,__ .,.•,.. ....w,,..,.,.o,...,.,asvwu+ .. - , .*rF07m .a^,M ,� y v..
i
,
File•
•
D 02_0190
35mm D i
•
#1
0 Inch 1/16 1 2 I 3 d
5 6
.
4 YIESTCr7r
■■■•■
I III�IIIIIIIIIIIIIIIIIII�IIIIIIIIIIIIII�IIII III; III. VIIIIIIIIIIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIIIIJIIIIIIIII�IIII�IIIIIIIIIIIIIIIIIIIIIIJ iI��
REViS
BE elE � �� SE
SEPARATE E PEPI; /11T
�,, %;E ®� � BUILDING �BV iSK . REQUIRED FOR: I I
DV �vlr,n��� w�►.�. � c�ui� �► nr'���t -,� r:� 2(1 AL .......
Mi ELECTRICAL
r N G ...- ......
Exit corridor
Strander Boulevard GAS PIPING i ___
, 9 I I .
CITY OF T U K W I L A 1 Exit corridor
I Exit corridor
Exit corridor
Exit corridor Q0
INIMMINEM 1 P ' \ \\\ \ \ .\ \ \ \\ 1
4
_ . , . ,_ _ ., .. _.�_..._.. _._� Property Line.
1 I I 1 I
I Unders'and that the PI ,n Check approvals are - cI Q TU( OF
c t to arrors :r c,ns an
�`� b ; r r °�ili;:. d approval of - l� c* A `� , 54 Center D, 1st fl oor (1 :300)
plans does not authorize the violation of any to JUL - 2 200
adopted code or ordinance. f eceir;i of con- -
tractor's copy of approved plans acknowledged. I i t \ 'L* PERMIT CENTER
Centerplex B � : � k1.-
320 5 ' �.�,
A ; ' ' ``
By / vs
Qy M a it d,r rte` - .
Date ; Site (1:1200) Room Room 190A Room 190B m
Permit l2.� I 190C
Room 170A
Construction/Occupancy Note:
Centerplex D is of Type V -N construction and has a Group F, 1/2 eyebolt with
ilk
1 0 washer, nut at top ;
Division 2, occupancy. and bottom
12 gauge wire hanger, -� - i
Parking Note: fasten to structure above
@ 8'0" O.C.
Site is required to have stalls for parking of 66 Room 170B R oom 190D
vehicles according to total interior area of building.
Actual number of vehicle stalls = 90. i mm.m. Existing suspended
F -- — ceiling system Existing 3o ,, Restore previously
high drywall
Metal tr ack ex f h eight
Fire Protection Note: i p to be drywall partition
, i rY P
Previous drywall partition shall be restored, causing restoration � 2" x 4" 25 ga. steel stL�ds @ 24" 3 extended
of sprinkler -head positions complying with all applicable codes. O.C. with R -11 sound batt insulation, :t
covered with 1/2" sound board 1 side `'
& 5/8" type "X" GWB each side 3
Space Use Note: ;
All rooms in floor plan not otherwise labeled shall be Track attached with screws to
used for general office ' lightweight concrete & plywood
g ce purposes.
subfloor @ 24" 0.C. r� . _......
Existing glued -down carpet Work Site (1:100)
Rubber base I ----- (optionally under partition)
Existing floor
New artition detail ente ex p (no scale) Division
D a_ 1
I I .. � 1 I I " I I' I ill l i j i i I l i l i l . 1 4 , I I I I i I I
0 Inch 1/16 1 2 3 d 5 6
II II IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1IIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIII1IIIIIIIII�IIIIIIIIIIIIIIIIIII1IIIIIII II�IIIIIIIII1IIIIIIIIIIIm
,